WorldWideScience

Sample records for voltage clamp analysis

  1. Comparative Analysis of PWM Techniques for Three Level Diode Clamped Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Zulkifilie Bin Ibrahim

    2014-07-01

    Full Text Available Multilevel inverters are increasingly being used in high-power medium voltage industrial drive applications due to their superior performance compared to conventional two-level inverters. Thre are a number of Pulse width modulation (PWM techniques applied in recent years. The most widely applied PWM techniques are Sine Pulse Width Modulation (SPWM and Space Vector Pulse Width Modulation (SVPWM.  SPWM is the most simple modulation technique that can realize easily in analog circuit.  However, it has some drawbacks such as higher total harmonic distortion (THD, lower effective DC utilization and lower switching frequency. Space vector pulse width modulation (SVPWM is widely used because of their easier digital realization and better DC bus utilization and lower THD. The complexity is due to the difficulty in determining the reference vector location, on times calculation, and switching states selection. This paper presents a simple SVPWM algorithm for diode clamped three level inverters based on standard two-level SVPWM which can easily determine the location of reference vector, calculate the on-times, the selection of switching states. Three level diode clamped inverter (3LDCI using space vector modulation technique has been modeled and simulated using MATLAB/SIMULINK and Origin 6.1 with a passive R-L load that can be extended to any level. Simulation results are presented to verify the proposed SVPWM control in terms of THD. The results are compared with conventional sinusoidal pulse width modulation (SPWM where SVPWM shows better performance than SPWM in terms of THD.

  2. Imperfect space clamp permits electrotonic interactions between inhibitory and excitatory synaptic conductances, distorting voltage clamp recordings.

    Directory of Open Access Journals (Sweden)

    Alon Poleg-Polsky

    Full Text Available The voltage clamp technique is frequently used to examine the strength and composition of synaptic input to neurons. Even accounting for imperfect voltage control of the entire cell membrane ("space clamp", it is often assumed that currents measured at the soma are a proportional indicator of the postsynaptic conductance. Here, using NEURON simulation software to model somatic recordings from morphologically realistic neurons, we show that excitatory conductances recorded in voltage clamp mode are distorted significantly by neighboring inhibitory conductances, even when the postsynaptic membrane potential starts at the reversal potential of the inhibitory conductance. Analogous effects are observed when inhibitory postsynaptic currents are recorded at the reversal potential of the excitatory conductance. Escape potentials in poorly clamped dendrites reduce the amplitude of excitatory or inhibitory postsynaptic currents recorded at the reversal potential of the other conductance. In addition, unclamped postsynaptic inhibitory conductances linearize the recorded current-voltage relationship of excitatory inputs comprising AMPAR and NMDAR-mediated components, leading to significant underestimation of the relative contribution by NMDARs, which are particularly sensitive to small perturbations in membrane potential. Voltage clamp accuracy varies substantially between neurons and dendritic arbors of different morphology; as expected, more reliable recordings are obtained from dendrites near the soma, but up to 80% of the synaptic signal on thin, distant dendrites may be lost when postsynaptic interactions are present. These limitations of the voltage clamp technique may explain how postsynaptic effects on synaptic transmission could, in some cases, be attributed incorrectly to presynaptic mechanisms.

  3. Common voltage eliminating of SVM diode clamping three-level inverter connected to grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    A novel method of common voltage eliminating is put forward for SVM diode clamping three-level inverter connected to grid by calculation of common voltage of its various switching states. PLECS is used to model this three-level inverter connected to grid and good results are obtained. First...... analysis of common mode voltage for switching states of diode clamping 3-level inverter is given in detail. Second the common mode voltage eliminating control strategy of SVM is described for diode clamping three-level inverter. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping...... three-level inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is a very powerful tool to real power circuits modeling. They have also verified that proposed common mode voltage eliminating control strategy of SVM is feasible...

  4. Comparative Analysis of Different PWM Techniques to Reduce the Common Mode Voltage in Three-Level Neutral-Point-Clamped Inverters for Variable Speed Induction Drives

    Directory of Open Access Journals (Sweden)

    Bharati Raja

    2012-12-01

    Full Text Available This work presents the comparative study of the different PWM techniques to reduce the common-mode voltage (CMV at the output of neutral point diode clamped inverter for variable speed drives. Here the comparative study is done by the phase opposition disposed (POD, sinusoidal pulse width modulation (SPWM, phase disposition (PD, phase shift (PS space vector modulation (SVM techniques are proposed. A good trade-off between the quality of the output voltage and the partial magnitude of the CMV is achieved in this work. The scheme is proposed for three-level inverter. This work realizes the implementation of Three-level diode clamped MLI for three-phase (Y-Δ induction motor with the implementation of a space vector modulation technique without any additional control algorithm to reduce CMV within the range + Vdc/6. The Simulation with a 1HP induction motor drive system is setup in Matlab-2011b  and the same results validated effectively by hardware – FPGA-SPARTEN III processor and its shows that the CM voltage is effectively reduced and the maximum output voltage is not affected.  

  5. Analysis of the effects of calcium or magnesium on voltage-clamp currents in perfused squid axons bathed in solutions of high potassium.

    Science.gov (United States)

    Rojas, E; Taylor, R E; Atwater, I; Bezanilla, F

    1969-10-01

    Isolated axons from the squid, Dosidicus gigas, were internally perfused with potassium fluoride solutions. Membrane currents were measured following step changes of membrane potential in a voltage-clamp arrangement with external isosmotic solution changes in the order: potassium-free artificial seawater; potassium chloride; potassium chloride containing 10, 25, 40 or 50, mM calcium or magnesium; and potassium-free artificial seawater. The following results suggest that the currents measured under voltage clamp with potassium outside and inside can be separated into two components and that one of them, the predominant one, is carried through the potassium system. (a) Outward currents in isosmotic potassium were strongly and reversibly reduced by tetraethylammonium chloride. (b) Without calcium or magnesium a progressive increase in the nontime-dependent component of the currents (leakage) occurred. (c) The restoration of calcium or magnesium within 15-30 min decreases this leakage. (d) With 50 mM divalent ions the steady-state current-voltage curve was nonlinear with negative resistance as observed in intact axons in isosmotic potassium. (e) The time-dependent components of the membrane currents were not clearly affected by calcium or magnesium. These results show a strong dependence of the leakage currents on external calcium or magnesium concentration but provide no support for the involvement of calcium or magnesium in the kinetics of the potassium system.

  6. Sites and mechanisms of antibiotic-induced neuromuscular block: a pharmacological analysis using quantal content, voltage clamped end-plate currents and single channel analysis.

    Science.gov (United States)

    Fiekers, J F

    1999-01-01

    Since the original observation of Vital Brazil and Corrado (1957) concerning the antibiotic induced neuromuscular block produced by streptomycin, there has been considerable interest in the mechanisms responsible for not only neuromuscular block but also the effects of antibiotics on different systems. We used the voltage clamped end-plate of transacted skeletal muscle to examine the concentration-dependent actions of several groups of antibiotics. The aminoglycoside antibiotics, neomycin and streptomycin, were both more effective at reducing quantal release of acetylcholine (ACh) than interacting with the postjunctional ACh receptor-channel complex. Neomycin was approximately 10 X more potent prejunctionally than streptomycin and the prejunctional effects of each antibiotic were reversed competitively by raising extracellular calcium. Both neomycin and streptomycin also had postjunctional actions at higher concentrations. Neomycin interacted with the open state of the ACh receptor ion channel complex while streptomycin blocks the ACh receptor. The lincosamide antibiotics, lincomycin and clindamycin produced their neuromuscular block postjunctionally by interacting with the open state of the ACh-receptor channel complex. Clindamycin is approximately 20 X more effective at blocking the open channel than was lincomycin. Using cell attached patch clamp recordings in cultured rat myotubes, we demonstrated a lincosamide-induced block of open ion channels with clindamycin having a much slower unblocking rate than lincomycin. Using epimers of the lincosamides, we demonstrated that lipophilicity of the molecule, rather than stereochemical considerations, is important for open channel blockade affecting primarily the "off" rate of channel blocking. This mechanism appears important for not only the lincosamide antibiotics but also for the postjunctional actions of the aminoglycoside antibiotics, particularly neomycin.

  7. Potassium Chloride Versus Voltage Clamp Contractures in Ventricular Muscle

    Science.gov (United States)

    Morad, M.; Reeck, S.; Rao, M.

    1981-01-01

    In frog ventricle, developed tension was markedly larger in response to depolarization caused by a voltage clamp step than to depolarization induced by high concentrations of potassium chloride. Measurement of extracellular potassium activity at the surface and at the depth of muscle during the development of contractures showed that the diffusion of potassium is much slower than the spread of depolarization through the cross section of muscle. These two observations suggest that competition between the depolarizing and the negative inotropic effects of an increase in the extracellular potassium ion concentration may determine the time course and magnitude of contractile tension in heart muscle.

  8. Effect of terfenadine and pentamidine on the HERG channel and its intracellular trafficking: combined analysis with automated voltage clamp and confocal microscopy.

    Science.gov (United States)

    Tanaka, Hikaru; Takahashi, Yukiko; Hamaguchi, Shogo; Iida-Tanaka, Naoko; Oka, Takayuki; Nishio, Masato; Ohtsuki, Atsushi; Namekata, Iyuki

    2014-01-01

    The effects of terfenadine and pentamidine on the human ether-a-go-go related gene (hERG) channel current and its intracellular trafficking were evaluated. Green fluorescent protein (GFP)-linked hERG channels were expressed in HEK293 cells, and the membrane current was measured by an automated whole cell voltage clamp system. To evaluate drug effects on channel trafficking to the cell membrane, the fraction of channel present on the cell membrane was quantified by current measurement after drug washout and confocal microscopy. Terfenadine directly blocked the hERG channel current but had no effect on trafficking of hERG channels to the cell membrane after application in culture medium for 2 d. In contrast, pentamidine had no direct effect on the hERG channel current but reduced trafficking of hERG channels. The two drugs inhibited hERG channel function through different mechanisms: terfenadine through direct channel blockade and pentamidine through inhibition of channel trafficking to the cell membrane. Combined use of automated voltage clamp and confocal microscopic analyses would provide insights into the mechanisms of drug-induced QT-prolongation and arrhythmogenesis.

  9. Novel Low Loss Active Voltage Clamp Circuit for Series Connection of RCGCT thyristors

    Science.gov (United States)

    Ito, Hiroshi; Suzuki, Akihiro; Iwata, Akihiko

    This paper describes novel low loss active voltage clamp circuits for the series connection of RCGCT thyristors. For high voltage converters the series connection of power semiconductor devices is an essential technique for direct switching of high voltages. Several protection circuits have been applied to the series connection of RCGCT thyristors such as CRD snubber circuits which suppress over-voltages across RCGCT thyristors, and voltage balancing resistors to equalize voltage sharing in steady states. However, significant losses in these protection circuits lower the converter’s efficiency. We propose novel low-loss protection circuits, which have active voltage clamp snubber circuits and static voltage balancing circuits. The clamp capacitor voltage of the active voltage clamp snubber circuits are designed to be higher than the equally divided DC-Link voltage. This method can reduce the loss of the clamp circuit to no more than 1/10 of that of the conventional CRD snubber. Also the static voltage balancing circuits compensate for the voltage imbalance generated by the difference in the leakage current between the series connection RCGCT thyristors.

  10. Suppression of Spiral Waves by Voltage Clamp Techniques in a Conductance-Based Cardiac Tissue Model

    Institute of Scientific and Technical Information of China (English)

    YU Lian-Chun; MA Jun; ZHANG Guo-Yong; CHEN Yong

    2008-01-01

    A new control method is proposed to control the spatio-temporal dynamics in excitable media, which is described by the Morris-Lecar cells model. It is confirmed that successful suppression of spiral waves can be obtained by spatially clamping the membrane voltage of the excitable cells. The low voltage clamping induces breakup of spiral waves and the fragments are soon absorbed by low voltage obstacles, whereas the high voltage clamping generates travel waves that annihilate spiral waves through collision with them. However, each method has its shortcomings. Furthermore, a two-step method that combines both low and high voltage clamp techniques is then presented as a possible way of out this predicament.

  11. A novel latch-up free SCR-LDMOS with high holding voltage for a power-rail ESD clamp

    Institute of Scientific and Technical Information of China (English)

    Pan Hongwei; Liu Siyang; Sun Weifeng

    2013-01-01

    The low snapback holding voltage of the SCR-LDMOS device makes it susceptible to latch-up failure,when used in power-rail ESD (electro-static discharge) clamp circuits.In order to eliminate latch-up risk,this work presents a novel SCR-LDMOS structure with an N-type implantation layer to achieve a 17 V holding voltage and a 5.2 A second breakdown current.The device has been validated using TLP measurement analysis and is applied to a power-rail ESD clamp in half-bridge driver ICs.

  12. Modeling CICR in rat ventricular myocytes: voltage clamp studies

    Directory of Open Access Journals (Sweden)

    Palade Philip T

    2010-11-01

    Full Text Available Abstract Background The past thirty-five years have seen an intense search for the molecular mechanisms underlying calcium-induced calcium-release (CICR in cardiac myocytes, with voltage clamp (VC studies being the leading tool employed. Several VC protocols including lowering of extracellular calcium to affect Ca2+ loading of the sarcoplasmic reticulum (SR, and administration of blockers caffeine and thapsigargin have been utilized to probe the phenomena surrounding SR Ca2+ release. Here, we develop a deterministic mathematical model of a rat ventricular myocyte under VC conditions, to better understand mechanisms underlying the response of an isolated cell to calcium perturbation. Motivation for the study was to pinpoint key control variables influencing CICR and examine the role of CICR in the context of a physiological control system regulating cytosolic Ca2+ concentration ([Ca2+]myo. Methods The cell model consists of an electrical-equivalent model for the cell membrane and a fluid-compartment model describing the flux of ionic species between the extracellular and several intracellular compartments (cell cytosol, SR and the dyadic coupling unit (DCU, in which resides the mechanistic basis of CICR. The DCU is described as a controller-actuator mechanism, internally stabilized by negative feedback control of the unit's two diametrically-opposed Ca2+ channels (trigger-channel and release-channel. It releases Ca2+ flux into the cyto-plasm and is in turn enclosed within a negative feedback loop involving the SERCA pump, regulating[Ca2+]myo. Results Our model reproduces measured VC data published by several laboratories, and generates graded Ca2+ release at high Ca2+ gain in a homeostatically-controlled environment where [Ca2+]myo is precisely regulated. We elucidate the importance of the DCU elements in this process, particularly the role of the ryanodine receptor in controlling SR Ca2+ release, its activation by trigger Ca2+, and its

  13. New active load voltage clamp for HF-link converters

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, M.A.E.

    2005-07-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core. (au)

  14. New active load voltage clamp for HF-link converters

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path du...... during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core....

  15. Advanced patch-clamp techniques and single-channel analysis

    NARCIS (Netherlands)

    Biskup, B; Elzenga, JTM; Homann, U; Thiel, G; Wissing, F; Maathuis, FJM

    1999-01-01

    Much of our knowledge of ion-transport mechanisms in plant cell membranes comes from experiments using voltage-clamp. This technique allows the measurement of ionic currents across the membrane, whilst the voltage is held under experimental control. The patch-clamp technique was developed to study t

  16. High Efficiency Interleaved Active Clamped Dc-Dc Converter with Fuel Cell for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Sona P

    2014-02-01

    Full Text Available A high efficiency interleaved ZVS active clamped current fed dc-dc converter is proposed in this paper specially used for fuel cell applications. As the fuel cell output is very low we are in need of a step up dc-dc converter. Here a current fed dc-dc converter is used. Two current fed dc-dc converters are interleaved by connecting their inputs in parallel and outputs in series. With this proposed methodology input current ripples in the fuel cell stacks can be reduced and a regulated output voltage ripples can be obtained. The active clamping circuit used in this model absorbs the turn off voltage spikes hence low voltage devices with low on state resistance can be used.Voltage doubler circuits will give double the output voltage than normal with smaller transformer turns ratio and flexibility. The proposed method is simulated in MATLAB for verifying the accuracy of the proposed design.

  17. An ANN Based Capicitor Voltage Balancing Method For Neutral Point Clamped Multi-Level Inverter

    Directory of Open Access Journals (Sweden)

    P.J.S. Praveen,

    2015-11-01

    Full Text Available Multi-level inverters are became popular for usage in medium voltage, low voltage power applications due to flexibility in control and better performance characteristics in terms of harmonic regulation. Neutral point clamped are popular as they require less number of sources as their input when compared with their counter parts i.e. cascaded multi-level inverters and found to be reliable when compared with flying capacitor based multi-level inverters. But when neutral clamped technologies are used for generation of three-phase voltages, the capacitors that are connected at input side experiences imbalance in their voltages, this makes neutral point clamped multi-level inverters less reliable. In the proposed work an attempt is made to study circuits that balances the capacitor voltages and a scheme is investigated for balancing the capacitor voltages. Method proposed in [1] uses PID controller for balancing the capacitor voltages. In this project PI based control scheme and artificial neural network (ANN based control scheme for the front end circuit shown in [1] are designed for achieving balance among the capacitor voltages. The proposed control scheme is simulated with the help of Simpowersystems block set and neural network toolbox of MATLAB software for different load conditions. Results obtained from ANN based controller and PI controller are presented.

  18. Calcium Release in Frog Cut Twitch Fibers Exposed to Different Ionic Environments under Voltage Clamp

    National Research Council Canada - National Science Library

    Hui, Chiu Shuen

    1999-01-01

    Calcium release was measured in highly stretched frog cut twitch fibers mounted in a double Vaseline-gap voltage clamp chamber, with the internal solution containing 20 mM EGTA plus 0.4 or 1.8 mM added calcium...

  19. Control Method of Three-level Neutral-point-clamped Inverter Based on Voltage Vector Diagram Partition

    Institute of Scientific and Technical Information of China (English)

    SONG Wen-xiang; YAO Gang; CHEN Chen; CHEN Guo-cheng

    2008-01-01

    A new modulation approach was presented for the control of neutral-point (NP) voltage variation in the three-level NP-clamped voltage source inverter, and the average NP current model was established based on vector diagram partition. Thus, theory base was built for balancing control of NP potential. Theoretical analysis and experimental results indicate that the proposed method for NP balancing control vector synthesizing concept based can make the average NP current zero, and do not influence NP potential within every sample period. The effectiveness of proposed research approach was verified by simulative and experimental results.

  20. FPGA in-the-loop simulations of cardiac excitation model under voltage clamp conditions

    Science.gov (United States)

    Othman, Norliza; Adon, Nur Atiqah; Mahmud, Farhanahani

    2017-01-01

    Voltage clamp technique allows the detection of single channel currents in biological membranes in identifying variety of electrophysiological problems in the cellular level. In this paper, a simulation study of the voltage clamp technique has been presented to analyse current-voltage (I-V) characteristics of ion currents based on Luo-Rudy Phase-I (LR-I) cardiac model by using a Field Programmable Gate Array (FPGA). Nowadays, cardiac models are becoming increasingly complex which can cause a vast amount of time to run the simulation. Thus, a real-time hardware implementation using FPGA could be one of the best solutions for high-performance real-time systems as it provides high configurability and performance, and able to executes in parallel mode operation. For shorter time development while retaining high confidence results, FPGA-based rapid prototyping through HDL Coder from MATLAB software has been used to construct the algorithm for the simulation system. Basically, the HDL Coder is capable to convert the designed MATLAB Simulink blocks into hardware description language (HDL) for the FPGA implementation. As a result, the voltage-clamp fixed-point design of LR-I model has been successfully conducted in MATLAB Simulink and the simulation of the I-V characteristics of the ionic currents has been verified on Xilinx FPGA Virtex-6 XC6VLX240T development board through an FPGA-in-the-loop (FIL) simulation.

  1. Voltage- and space-clamp errors associated with the measurement of electrotonically remote synaptic events.

    Science.gov (United States)

    Spruston, N; Jaffe, D B; Williams, S H; Johnston, D

    1993-08-01

    1. The voltage- and space-clamp errors associated with the use of a somatic electrode to measure current from dendritic synapses are evaluated using both equivalent-cylinder and morphologically realistic models of neuronal dendritic trees. 2. As a first step toward understanding the properties of synaptic current distortion under voltage-clamp conditions, the attenuation of step and sinusoidal voltage changes are evaluated in equivalent cylinder models. Demonstration of the frequency-dependent attenuation of voltage in the cable is then used as a framework for understanding the distortion of synaptic currents generated at sites remote from the somatic recording electrode and measured in the voltage-clamp recording configuration. 3. Increases in specific membrane resistivity (Rm) are shown to reduce steady-state voltage attenuation, while producing only minimal reduction in attenuation of transient voltage changes. Experimental manipulations that increase Rm therefore improve the accuracy of estimates of reversal potential for electrotonically remote synapses, but do not significantly reduce the attenuation of peak current. In addition, increases in Rm have the effect of slowing the kinetics of poorly clamped synaptic currents. 4. The effects of the magnitude of the synaptic conductance and its kinetics on the measured synaptic currents are also examined and discussed. The error in estimating parameters from measured synaptic currents is greatest for synapses with fast kinetics and large conductances. 5. A morphologically realistic model of a CA3 pyramidal neuron is used to demonstrate the generality of the conclusions derived from equivalent cylinder models. The realistic model is also used to fit synaptic currents generated by stimulation of mossy fiber (MF) and commissural/associational (C/A) inputs to CA3 neurons and to estimate the amount of distortion of these measured currents. 6. Anatomic data from the CA3 pyramidal neuron model are used to construct a

  2. Analysis list: Clamp [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Clamp Cell line + dm3 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.1....tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clam...p.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Clamp.Cell_line.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Cell_line.gml ...

  3. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify the design, increase...... efficiency, reduce the product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented....

  4. Enhanced Buck–Boost Neutral-Point-Clamped Inverters With Simple Capacitive-Voltage Balancing

    DEFF Research Database (Denmark)

    Tan, Kuan Khoon; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    In traditional neutral-point-clamped (NPC) inverters, two major operating issues encountered are their relatively limited voltage-buck variation range and capacitive-voltage imbalance, which can cause low-order harmonics to appear at the inverter output. Various methodologies have so far been...... been investigated in the context of buck–boost energy conversion, even though relevant techniques for traditional NPC inverters do exist but are generally overburdened by the accompanied switching loss increase and more complex control and hardware circuitries. To address these two topological concerns...... simultaneously, two new buck–boost NPC inverters with simple capacitive-voltage-balancing capability are proposed. Both inverters are demonstrated to exhibit a doubling of voltage gain, with one of them also shown to produce a better output waveform quality. Simulation and experimental results are provided...

  5. A low-voltage sense amplifier with two-stage operational amplifier clamping for flash memory

    Science.gov (United States)

    Guo, Jiarong

    2017-04-01

    A low-voltage sense amplifier with reference current generator utilizing two-stage operational amplifier clamp structure for flash memory is presented in this paper, capable of operating with minimum supply voltage at 1 V. A new reference current generation circuit composed of a reference cell and a two-stage operational amplifier clamping the drain pole of the reference cell is used to generate the reference current, which avoids the threshold limitation caused by current mirror transistor in the traditional sense amplifier. A novel reference voltage generation circuit using dummy bit-line structure without pull-down current is also adopted, which not only improves the sense window enhancing read precision but also saves power consumption. The sense amplifier was implemented in a flash realized in 90 nm flash technology. Experimental results show the access time is 14.7 ns with power supply of 1.2 V and slow corner at 125 °C. Project supported by the National Natural Science Fundation of China (No. 61376028).

  6. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify design, increase efficiency and integration level, reduce product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented. (au)

  7. Delayed cord clamping and cord gas analysis at birth.

    Science.gov (United States)

    Xodo, Serena; Xodo, Luigi; Berghella, Vincenzo

    2017-09-16

    Delayed cord clamping for at least 60 seconds in both term and preterm babies is a major recent change in clinical care. Delayed cord clamping has several effects on other possible interventions. One of these is the effect of delayed cord clamping on umbilical artery gas analysis. When indicated, umbilical artery gas analysis can safely be done either with early cord clamping, or, probably most of the times it is necessary, during delayed cord clamping with the cord still unclamped. Paired blood samples (one from the umbilical artery and one from the umbilical vein) can be taken from the pulsating and unclamped cord, immediately after birth, during delayed cord clamping, without any effect on either the accuracy of umbilical artery gas analysis or on the transfusion of blood through delayed cord clamping. Umbilical artery gas analysis should instead not be done after delayed cord clamping, since delayed cord clamping alters several acid-based parameters and lactate values. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. A numerical approach to ion channel modelling using whole-cell voltage-clamp recordings and a genetic algorithm.

    Directory of Open Access Journals (Sweden)

    Meron Gurkiewicz

    2007-08-01

    Full Text Available The activity of trans-membrane proteins such as ion channels is the essence of neuronal transmission. The currently most accurate method for determining ion channel kinetic mechanisms is single-channel recording and analysis. Yet, the limitations and complexities in interpreting single-channel recordings discourage many physiologists from using them. Here we show that a genetic search algorithm in combination with a gradient descent algorithm can be used to fit whole-cell voltage-clamp data to kinetic models with a high degree of accuracy. Previously, ion channel stimulation traces were analyzed one at a time, the results of these analyses being combined to produce a picture of channel kinetics. Here the entire set of traces from all stimulation protocols are analysed simultaneously. The algorithm was initially tested on simulated current traces produced by several Hodgkin-Huxley-like and Markov chain models of voltage-gated potassium and sodium channels. Currents were also produced by simulating levels of noise expected from actual patch recordings. Finally, the algorithm was used for finding the kinetic parameters of several voltage-gated sodium and potassium channels models by matching its results to data recorded from layer 5 pyramidal neurons of the rat cortex in the nucleated outside-out patch configuration. The minimization scheme gives electrophysiologists a tool for reproducing and simulating voltage-gated ion channel kinetics at the cellular level.

  9. Substance P-mediated membrane currents in voltage-clamped guinea pig inferior mesenteric ganglion cells.

    Science.gov (United States)

    Griffith, W H; Hills, J M; Brown, D A

    1988-01-01

    Responses to substance P (SP) and to hypogastric nerve stimulation were recorded from voltage-clamped guinea pig inferior mesenteric ganglion (IMG) neurons, and compared with those to muscarine. Muscarine produced a voltage-dependent inward current accompanied by a reduced input conductance and inhibition of IM a time- and voltage-dependent K+-current (Brown and Adams: Nature 283:673-676, 1980). SP also produced an inward current, accompanied by a fall in input conductance (20 out of 31 cells) or a rise in input conductance (7 out of 31 cells). The fall in input conductance was not accompanied by an inhibition of M-current (unlike frog ganglia: Adams et al.: British Journal of Pharmacology 79:330-333, 1983) or an inhibition of the inward rectifier current (unlike globus pallidus neurons: Stanfield et al.: Nature 315:498-501, 1985). Repetitive hypogastric nerve stimulation (10-20 Hz, 2-10 s) produced a slow inward postsynaptic current lasting 1-3 min, with decreases or increases of input conductance matching those produced by SP. The postsynaptic current did not show a consistent or reproducible change in amplitude on varying the holding potential between -90 and -25 mV. It is concluded that SP and hypogastric stimulation produce complex and variable changes in ionic conductance in IMG neurons.

  10. Three Phase Two Leg Neutral Point Clamped Converter with output DC Voltage Regulation and Input Power Factor Correction

    Directory of Open Access Journals (Sweden)

    Bogimi Sirisha

    2012-03-01

    Full Text Available In this paper, a three-phase two leg neutral point clamped (NPC converter is presented for power factor correction and dc-link voltage regulation. The adopted converter has simpler circuit configuration and less number of power switches compared to three-level PWM converter. In this circuit configuration, only eight power switches and four clamping diodes with voltage stress of half the dc bus voltage are used. A simplified space vector pulse width modulation scheme (SVPWM is also adopted to track the line current commands. A reference voltage vector is generated on the ac terminal for drawing the sinusoidal line currents with unity power factor. This algorithm reduces the time required to calculate the switching time durations of voltage vectors. The simulation results have been presented to verify the validity and effectiveness of the proposed control strategy.

  11. How the early voltage clamp studies of José del Castillo inform "modern" neuroscience.

    Science.gov (United States)

    Zottoli, Steven J

    2012-10-01

    The description of ionic currents that flow across the membrane of the squid giant axon during an action potential sparked an interest in determining whether there were similar currents in vertebrates. The preparation of choice was the node of Ranvier in single myelinated fibers in frog. José del Castillo spent 3 years on the United States mainland from 1956 to 1959. During that time, he collaborated with Jerome Y. Lettvin and John W. Moore. I discuss how these individuals met one another and some of their scientific discoveries using the voltage clamp to study squid giant axons and frog nodes. Much of this work was conducted at the Marine Biological Laboratory in Woods Hole, MA, and I attempt to convey a sense of the unique scientific "melting pot" that existed at the Marine Biological Laboratory and the broader effect that del Castillo had on "modern" neuroscience.

  12. Analytical evaluation of DC capacitor RMS current and voltage ripple in neutral-point clamped inverters

    Indian Academy of Sciences (India)

    K S GOPALAKRISHNAN; SANTOSH JANAKIRAMAN; SOUMITRA DAS; G NARAYANAN

    2017-06-01

    The sizing of the DC-link capacitor in a three-level inverter is based on the RMS current flowing through it. This paper analyses the DC-link capacitor RMS current in a neutral-point clamped (NPC) inverter and expresses the same as a function of modulation index, line-side current amplitude and power factor. Analytical closed-form expressions are derived for the capacitor RMS current for single-phase half-bridge,single-phase full-bridge and three-phase three-leg topologies of a three-level inverter. The worst-case capacitor current stress is determined for each topology based on the analytical expressions. Further, analytical expressions are derived for the RMS values of low-frequency and high-frequency capacitor currents. These expressions are then used to estimate voltage ripple across the DC capacitor for sinusoidally modulated three-phase NPC inverter. The analytical expressions for the RMS current and voltage ripple are validated experimentally over a wide range of operating points.

  13. Five-Level Active-Neutral-Point-Clamped DC/DC Converter for Medium-Voltage DC Grids

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2017-01-01

    effectively eliminate high voltage leaps caused by the dead time effect. In addition, a capacitor voltage control strategy is proposed for the 5L-ANPC dc/dc converter to ensure the balanced flying capacitor voltage and desired five-level voltage waveforms. Finally, simulation and experimental studies......This paper proposes a five-level active-neutralpoint- clamped (5L-ANPC) dc/dc converter for applications in medium voltage dc (MVDC) grids. A modulation strategy is proposed for the 5L-ANPC dc/dc converter to generate multilevel voltage waveforms, which can effectively reduce voltage change rate dv...... are conducted, and the results have verified the proposed converter and control strategies....

  14. How Does Patch Clamp Work?--An easy approach to understanding patch clamp mechanism

    Institute of Scientific and Technical Information of China (English)

    关兵才; 李之望

    2003-01-01

    In order to help patch clamp users,most of whom are not good enough at electrics and electronics,to understandthe complicated principles of patch clamp technique,we present a readily accessible explanation of patch clamp mechanism,in-cluding basic analysis of membrane currents under voltage clamp,achievement of voltage clamp and current recording,capaci-tance compensation,series resistance compensation,voltage offset correction,leak subtraction and current clamp,based on ourworking and teaching experience and with the aid of some useful formulae.

  15. Effect of delayed umbilical cord clamping on blood gas analysis.

    Science.gov (United States)

    Valero, Javier; Desantes, Domingo; Perales-Puchalt, Alfredo; Rubio, Juan; Diago Almela, Vicente J; Perales, Alfredo

    2012-05-01

    To ascertain if there are differences in umbilical cord blood gas analysis between immediate and delayed cord clamping. In a prospective observational study on 60 vaginally delivered healthy term newborns, we sampled umbilical cord blood immediately after delivery and at the time umbilical cord pulsation spontaneously ceased. There were significant decreases in pH, oxygen saturation (sO(2)), glycemia, oxygen content (ctO(2)), bicarbonate (HCO(3)(-)) and base excess (BE). Lactate and [Formula: see text] increased. Delayed cord clamping pH correlated with immediate cord clamping pH, [Formula: see text] , ctHb, sO(2) and time (r(2)=0.77, pcord clamping lactate was associated with immediate cord clamping lactate and time (r(2)=0.83, pcord clamping alters acid-base parameters and lactate values compared to immediate cord clamping. Those variations depend mainly on time, prior pH and lactate. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. A DC-Link Voltage Self-Balance Method for a Diode-Clamped Modular Multilevel Converter With Minimum Number of Voltage Sensors

    DEFF Research Database (Denmark)

    Gao, Congzhe; Jiang, Xinjian; Li, Yongdong

    2013-01-01

    Voltage balance issue of dc-link capacitors is very important for applications of a cascade multilevel converter or a modular multilevel converter. In this paper, a novel diode-clamped modular multilevel converter (DCM2C) topology is proposed and a power feedback control method is developed...

  17. Isolated PWM DC-AC SICAM with an active capacitive voltage clamp[Pulse Density Modulated; Pulse Width Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, i.e. a true bidirectional bridge, which operation is aimed towards amplification of the audio signal. In order to solve the problem with the commutation of the load current, a dead time between the incoming and outgoing bidirectional switch is implemented, while a capacitive voltage clamp is used to keep the induced overvoltage to reasonable levels. The energy stored in the clamping capacitor is not wasted as in the dissipative clamps, but is rather transferred back to the primary side for further processing using an auxiliary isolated single-switch converter, i.e. an active clamping technique is used. (au)

  18. Voltage-clamp studies of transient inward current and mechanical oscillations induced by ouabain in ferret papillary muscle.

    Science.gov (United States)

    Karagueuzian, H S; Katzung, B G

    1982-06-01

    1. We studied the effects of a toxic concentration of ouabain on transmembrane electrical activity and on mechanical behaviour of right ventricular papillary muscles from ferrets in a single sucrose-gap using current clamp and voltage clamp.2. Ouabain (1.4-1.8 muM) induced oscillatory after-potentials and after-concentrations in current-clamp experiments. Voltage clamp showed that the oscillatory after-potential was caused by a transient inward current, similar to that in Purkinje fibres.3. The transient current had a sigmoidal dependence on the preceding (activating) voltage step V1, with a treshold around -13 mV and a plateau between +10 and 20 mV. There was a decline in current amplitude for more positive clamps. When activated by a fixed V1 voltage step, and measured at different repolarization levels V2, the transient current manifested an inverse dependence on V2 between -50 and -10 mV. No outward transient current could be detected. Total replacement of Na in the bathing medium by Tris or by sucrose abolished the transient current.4. Ouabain caused an increase of phasic (twitch) tension responses to voltage steps at all potentials without shifting the curve relating these variables on the voltage axis. The drug evoked an even greater increase in the tonic tension responses.5. After prolonged exposure, oscillatory mechanical responses were frequently recorded during positive voltage steps. Unlike the after-contraction, these mechanical fluctuations were not consistently damped and were not accompanied by detectable synchronous current fluctuations. Catecholamines and dibutyryl cyclic AMP markedly reduced the amplitude of the tonic contraction and the mechanical oscillations but increased their frequency. Caffeine had no effect on the tonic contraction amplitude but abolished the fluctuations.6. These results support the proposal that Ca is transiently released from the overloaded sarcoplasmic reticulum in ouabain-intoxicated muscle and may evoke oscillatory

  19. Characterization of heterologously expressed transporter genes by patch- and voltage-clamp methods: Application to cyclic nucleotide-dependent responses

    KAUST Repository

    Lemtiri-Chlieh, Fouad

    2013-09-03

    The application of patch- and voltage-clamp methods to study ion transport can be limited by many hurdles: the size of the cells to be patched and/or stabbed, the subcellular localization of the molecule of interest, and its density of expression that could be too low even in their own native environment. Functional expression of genes using recombinant DNA technology not only overcomes those hurdles but also affords additional and elegant investigations such as single-point mutation studies and subunit associations/regulations. In this chapter, we give a step-by-step description of two electrophysiological methods, patch clamp and two-electrode voltage clamp (TEVC), that are routinely used in combination with heterologous gene expression to assist researchers interested in the identification and characterization of ion transporters. We describe how to (1) obtain and maintain the cells suitable for the use with each of the above-mentioned methods (i.e., HEK-293 cells and yeast spheroplasts to use with the patch-clamp methodology and Xenopus laevis oocytes with TEVC), (2) transfect/inject them with the gene of interest, and (3) record ion transport activities. © Springer Science+Business Media New York 2013.

  20. Umbilical cord clamping. An analysis of a usual neonatological conduct.

    Science.gov (United States)

    Papagno, L

    1998-01-01

    Here we described a critical analysis of the neonatological procedure of early cord clamping, meaning this, within 40 seconds after birth. Fifty three cases are here analysed, in which this practice was not performed, but instead a late umbilical cord clamping was done after birth or after the cord had stopped beating. Variations in hematocrito values within 24 to 36 hours after birth were studied. A transitory polycithemia, with a maximum peak 12 hours post-delivery was observed. These values returned to normal levels between 24 and 36 hours after birth. K vitamin was not administered to any of the newborns. No pathology appeared related to this transitory polycithemia. In can be concluded that the late umbilical cord clamping represents no risk to the new-born and that the pathological phenomena described under these circumstances may be attributed to the increase in K vitamin dependent coagulation factors that are induced by the routinary administration of phitonadione to all normal newborns.

  1. New Modulation Strategy to Balance the Neutral-Point Voltage for Three-Level Neutral-Clamped Inverter Systems

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, June-Seok; Lee, Kyo-Beum

    2014-01-01

    This paper proposes a new modulation strategy that balances the neutral-point voltage for three-level neutral-clamped inverter systems. The proposed modulation replaces the P-type or N-type small switching states with other switching states that do not affect the neutral-point voltage. The zero...... and medium switching states are employed to help the neutral-point voltage balancing. This method little bit increases the switching events and output total harmonic distortion. However, this method has a strong balancing ability at all regions. Further, it is very simple to implement in both space vector...... modulation and carrier-based PWM methods. Simulation and experimental results verify the validity and feasibility of the proposed new modulation strategy....

  2. Simulation Based Performance analysis of Active Clamp DHB ZVZCS Bidirectional DC-DC converter for Low Power Applications

    Directory of Open Access Journals (Sweden)

    V.V.Subrahmanya Kumar Bhajana

    2012-06-01

    Full Text Available A novel active clamp dual half bridge DC/DC converter with bidirectional power flow is proposed in this paper and comparative analysis between active clamp DHB ZVZCS and ZVS-ZCS bidirectional DC-DC converter topologies is also presented. By adding active clamping circuits to both bridges, zero voltage and zero current switching are achieved to improve the performance of the bidirectional DC/DC converter. The principle of operation is analyzed and simulated. With the proposed active clamp ZVZCS concept, the MATLAB simulation results of the applications of the fuel cell and battery have been obtained and compared with those of ZVS-ZCS bidirectional converter. The simulation results of proposed converter is compared with the ZVS-ZCS bidirectional DC-DC converter, efficiency, switching losses are the key parameters compared.

  3. Voltage-Sharing Converter to Supply Single-Phase Asymmetrical Four-Level Diode-Clamped Inverter With High Power Factor Loads

    DEFF Research Database (Denmark)

    Boora, Arash A.; Nami, Alireza; Zare, Firuz

    2010-01-01

    The output voltage quality of some of the single-phase multilevel inverters can be improved when their dc-link voltages are regulated asymmetrically. Symmetrical and asymmetrical multilevel diode-clamped inverters have the problem of dc-link capacitor voltage balancing, especially when power factor...... of the load is close to unity. In this paper, a new single-inductor multi-output dc/dc converter is proposed that can control the dc-link voltages of a single-phase diode-clamped inverter asymmetrically to achieve voltage quality enhancement. The circuit of the presented converter is explained and the main...... equations are developed. A control strategy is proposed and explained in details. To validate the versatility of the proposed combination of the suggested dc–dc converter and the asymmetrical four-level diode-clamped inverter (ADCI), simulations and experiments have been directed. It is concluded...

  4. Pulse and Trapezoidal Voltage Clamp Applied To Jurkat Cells: A T- Lymphocyte Cell Line

    Science.gov (United States)

    1993-04-01

    clamp. (Upward deflection represents depolarization). Low frequency oscillations are clearly visible. Such oscillations have been described by Maltsev ...1952. (8) Maltsev , V. A. Oscillating and triggering properties of T cell membrane potential. Imun. Lett. 26:277-282, 1990. 13 (9) Gallin, E. K

  5. Voltage-clamp predictions by gompertz kinetics model relating squid-axon Na+-gating and ionic currents.

    Science.gov (United States)

    Easton, Dexter M

    2005-10-01

    Gompertz kinetics is a simple, realistic, accurate, and computationally parsimonious alternative for prediction of macroscopic changes in Na+ conductance during voltage clamp. Conductance delay and time course depend on initial amplitudes and decay rates of surrogates for the macroscopic gating currents. The model is tested by the fit to published data of other authors. The proposed physical basis for the model is that membrane potential perturbation triggers motion of charged "gating" components of the axon membrane at rapid (activating) and at slow (inactivating) rates. The resulting distortion increases and more slowly diminishes the probability that conduction channels will be open.

  6. An operational amplifier B1404UD1A-1 in the patch-clamp current-to-voltage converter.

    Science.gov (United States)

    Korzun, A M; Rozinov, S V; Abashin, G I

    1997-01-01

    The applicability of the home-made operational amplifier B1404UD1A-1 in a patch-clamp current-to-voltage converter was analyzed. Its parameters (background noise, input bias current, and gain-bandwidth product) were estimated. Schematic solutions and practical recommendations for the use of this amplifier in a current-to-voltage converter were given. Based on the background noise and frequency parameters of the converter, we found that this device can be used for measuring ion channel currents with a high sensitivity and within a broad frequency range (0.055 pA, to 1 kHz; 0.4 pA, to 10 kHz). An example of the converter application in experiments is given.

  7. Carrier-Based Common Mode Voltage Control Techniques in Three-Level Diode-Clamped Inverter

    Directory of Open Access Journals (Sweden)

    Pradyumn Chaturvedi

    2012-01-01

    Full Text Available Switching converters are used in electric drive applications to produce variable voltage, variable frequency supply which generates harmful large dv/dt and high-frequency common mode voltages (CMV. Multilevel inverters generate lower CMV as compared to conventional two-level inverters. This paper presents simple carrier-based technique to control the common mode voltages in multilevel inverters using different structures of sine-triangle comparison method such as phase disposition (PD, phase opposition disposition (POD by adding common mode voltage offset signal to actual reference voltage signal. This paper also presented the method to optimize the magnitude of this offset signal to reduce CMV and total harmonic distortion in inverter output voltage. The presented techniques give comparable performance as obtained in complex space vector-based control strategy, in terms of number of commutations, magnitude, and rate of change of CMV and harmonic profile of inverter output voltage. Simulation and experimental results presented confirm the effectiveness of the proposed techniques to control the common mode voltages.

  8. Active gate driver for dv/dt control and active voltage clamping in an IGBT stack

    DEFF Research Database (Denmark)

    Rasmussen, Tonny Wederberg

    2005-01-01

    For high voltages converters stacks of IGBTs can be used if the static and dynamic voltage sharing among the IGBTs can be applied. dVCE/dt should also be controlled in order not to damage insulation material. This paper describes theory and measurements of an active gate driver for stacking IGBTs...

  9. Analysis of the Pallet Clamping Conditions in Work Positioning

    Directory of Open Access Journals (Sweden)

    L. A. Kolesnikov

    2016-01-01

    Full Text Available Pallets of automatic transfer lines serve as the technological and work-transfer equipment. However, their design is based on the general principles of designing machine accessories. Calculation of the basic design parameters of work based on their functioning features is fairly relevant.In pallet transfer movement over work positioning there is a mismatch between axes of the basic bushing of a pallet and the clamping locks of positioning. The paper identifies the factors influencing it, and defines the conditions to ensure the trouble-free clamping lock. The circular and rhombic clamping of pallet is simultaneous. Further, a clamping load is calculated from the pallet mass (together with the work-piece and the geometric parameters of the pallet clamping.The paper reveals three movement stages of the clamping lock in a vertical plane when setting the pallet in work positioning:- a clamping lock free play till it encounters with the location bushing;- a clamping lock play length when the lead-in chamfer contacts the bushing chamfer;- a clamping lock play length over the circular surface of bushing.The study of this process has allowed us to calculate the time of pallet clamping and dynamic loads acting on the clamping lock. These calculations made it possible to calculate the required diameter of the clamping lock. The presented calculations allow a reasonable assigning the main design parameters of work positioning for the pallet automatic lines.

  10. How cesium dialysis affects the passive properties of pyramidal neurons: implications for voltage clamp studies of persistent sodium current

    Energy Technology Data Exchange (ETDEWEB)

    Fleidervish, Ilya A; Libman, Lior [Koret School of Veterinary Medicine, Hebrew University of Jerusalem, PO Box 12, Rehovot 76100 (Israel)], E-mail: fleider@agri.huji.ac.il

    2008-03-15

    In order to accurately understand and model neuronal integration in the brain, we must know the biophysical properties of channels that are located far from the soma, in the axonal and dendritic membranes of central nerve cells. Reliable electrophysiological measurements in these regions are difficult to obtain, because the processes are too tiny to directly study with an electrode. One common strategy is to record with a somatic electrode that contains Cs{sup +}, to dialyze the intracellular space with this K{sup +} channel blocker, and thereby to render the neuron electrotonically compact. Does this work? Here, we combine the experimental and modeling techniques to determine the extent to which a whole-cell voltage clamp, established with a Cs{sup +}-containing pipette in the soma of a cortical pyramidal cell, attains adequate voltage control of distal neuronal processes. We focus on the low-voltage-activated, slowly inactivating 'persistent' Na{sup +} current (I{sub NaP}), that plays a crucial role in determining neuronal excitability and synaptic integration.

  11. How cesium dialysis affects the passive properties of pyramidal neurons: implications for voltage clamp studies of persistent sodium current

    Science.gov (United States)

    Fleidervish, Ilya A.; Libman, Lior

    2008-03-01

    In order to accurately understand and model neuronal integration in the brain, we must know the biophysical properties of channels that are located far from the soma, in the axonal and dendritic membranes of central nerve cells. Reliable electrophysiological measurements in these regions are difficult to obtain, because the processes are too tiny to directly study with an electrode. One common strategy is to record with a somatic electrode that contains Cs+, to dialyze the intracellular space with this K+ channel blocker, and thereby to render the neuron electrotonically compact. Does this work? Here, we combine the experimental and modeling techniques to determine the extent to which a whole-cell voltage clamp, established with a Cs+-containing pipette in the soma of a cortical pyramidal cell, attains adequate voltage control of distal neuronal processes. We focus on the low-voltage-activated, slowly inactivating 'persistent' Na+ current (INaP), that plays a crucial role in determining neuronal excitability and synaptic integration.

  12. Analysis of Contact Characteristic of Overhead Line and Suspension Clamp

    Directory of Open Access Journals (Sweden)

    Zhao Xinze

    2013-01-01

    Full Text Available In this paper, a LGJ150/25 type ACSR transmission line and a CGU-3 type suspension clamp are taken as research objects. A contact model of the conductor and the clamp was established by using finite element method. The effects of sag angle of the conductor, holding force and tension force in section are analyzed. The results showed that the contact area in the middle of the clamp is of belt-like type. The extreme values of tress were observed on the edge of the contact area and near the edge of keeper. In clamp section, suspension angle had the greatest influence on contact stress, and then the clamp force. The tension force in section played a most important role in these affecting factors. In the exit section of clamp, the biggest impact factor was tension force in this section, then the suspension angle, the third was clamp force. The results provide theoretical basis on reducing corona loss, optimization the clamp. Doubtlessly, the conclusion has important theoretical significance and application value.

  13. Transformer-based asymmetrical embedded Z-source neutral point clamped inverters with continuous input current and enhanced voltage boost capability

    DEFF Research Database (Denmark)

    Mo, W.; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    Z-source Neutral Point Clamped (NPC) inverters were introduced to integrate both the advantages of Z-source inverters and NPC inverters. However, traditional Z-source inverters suffer from high voltage stress and chopping input current. This paper proposes six types transformer-based impedance-source...... NPC inverters which have enhanced voltage boost capability and continuous input current by utilizing of transformer and embedded dc source configuration. Experimental results are presented to verify the theory validation....

  14. Overmodulation of n-level three-leg DC-AC diode-clamped converters with comprehensive capacitor voltage balance

    DEFF Research Database (Denmark)

    Busquets-Monge, S.; Maheshwari, Ram Krishan; Munk-Nielsen, Stig

    2013-01-01

    This paper presents a novel PWM strategy for nlevel three-leg semiconductor-clamped dc-ac converters in the overmodulation region, with dc-link capacitor voltage balance in every switching cycle. The strategy is based on the virtual-vector concept. Suitable reference vector trajectories are selec...

  15. Control of gastric H,K-ATPase activity by cations, voltage and intracellular pH analyzed by voltage clamp fluorometry in Xenopus oocytes.

    Directory of Open Access Journals (Sweden)

    Katharina L Dürr

    Full Text Available Whereas electrogenic partial reactions of the Na,K-ATPase have been studied in depth, much less is known about the influence of the membrane potential on the electroneutrally operating gastric H,K-ATPase. In this work, we investigated site-specifically fluorescence-labeled H,K-ATPase expressed in Xenopus oocytes by voltage clamp fluorometry to monitor the voltage-dependent distribution between E(1P and E(2P states and measured Rb(+ uptake under various ionic and pH conditions. The steady-state E(1P/E(2P distribution, as indicated by the voltage-dependent fluorescence amplitudes and the Rb(+ uptake activity were highly sensitive to small changes in intracellular pH, whereas even large extracellular pH changes affected neither the E(1P/E(2P distribution nor transport activity. Notably, intracellular acidification by approximately 0.5 pH units shifted V(0.5, the voltage, at which the E(1P/E(2P ratio is 50∶50, by -100 mV. This was paralleled by an approximately two-fold acceleration of the forward rate constant of the E(1P→E(2P transition and a similar increase in the rate of steady-state cation transport. The temperature dependence of Rb(+ uptake yielded an activation energy of ∼90 kJ/mol, suggesting that ion transport is rate-limited by a major conformational transition. The pronounced sensitivity towards intracellular pH suggests that proton uptake from the cytoplasmic side controls the level of phosphoenzyme entering the E(1P→E(2P conformational transition, thus limiting ion transport of the gastric H,K-ATPase. These findings highlight the significance of cellular mechanisms contributing to increased proton availability in the cytoplasm of gastric parietal cells. Furthermore, we show that extracellular Na(+ profoundly alters the voltage-dependent E(1P/E(2P distribution indicating that Na(+ ions can act as surrogates for protons regarding the E(2P→E(1P transition. The complexity of the intra- and extracellular cation effects can be

  16. Analysis of the dynamic avalanche of carrier stored trench bipolar transistor (CSTBT) during clamped inductive turn-off transient

    Science.gov (United States)

    Xue, Peng; Fu, Guicui

    2017-03-01

    The dynamic avalanche has a huge impact on the switching robustness of carrier stored trench bipolar transistor (CSTBT). The purpose of this work is to investigate the CSTBT's dynamic avalanche mechanism during clamped inductive turn-off transient. At first, with a Mitsubishi 600 V/150 A CSTBT and a Infineon 600 V/200 A field stop insulated gate bipolar transistor (FS-IGBT) utilized, the clamped inductive turn-off characteristics are obtained by double pulse test. The unclamped inductive switching (UIS) test is also utilized to identify the CSTBT's clamping voltage under dynamic avalanche condition. After the test data analysis, it is found that the CSTBT's dynamic avalanche is abnormal and can be triggered under much looser condition than the conventional buffer layer IGBT. The comparison between the FS-IGBT and CSTBT's experimental results implies that the CSTBT's abnormal dynamic avalanche phenomenon may be induced by the carrier storage (CS) layer. Based on the semiconductor physics, the electric field distribution and dynamic avalanche generation in the depletion region are analyzed. The analysis confirms that the CS layer is the root cause of the CSTBT's abnormal dynamic avalanche mechanism. Moreover, the CSTBT's negative gate capacitance effect is also investigated to clarify the underlying mechanism of the gate voltage bump observed in the test. In the end, the mixed-mode numerical simulation is utilized to reproduce the CSTBT's dynamic avalanche behavior. The simulation results validate the proposed dynamic avalanche mechanisms.

  17. Dynamic Pull-In Investigation of a Clamped-Clamped Nanoelectromechanical Beam under Ramp-Input Voltage and the Casimir Force

    Directory of Open Access Journals (Sweden)

    Amir R. Askari

    2014-01-01

    Full Text Available The influence of the Casimir excitation on dynamic pull-in instability of a nanoelectromechanical beam under ramp-input voltage is studied. The ramp-input actuation has applications in frequency sweeping of RF-N/MEMS. The presented model is nonlinear due to the inherent nonlinearity of electrostatics and the Casimir excitations as well as the geometric nonlinearity of midplane stretching. A Galerkin based reduced order modeling is utilized. It is found that the calculated dynamic pull-in ramp input voltage leads to dynamic pull-in step input voltage by increasing the slope of voltage-time diagram. This fact is utilized to verify the results of present study.

  18. Size-dependent dynamic stability analysis of microbeams actuated by piezoelectric voltage based on strain gradient elasticity theory

    Energy Technology Data Exchange (ETDEWEB)

    Sahmani, Saeid; Bahrami, Mohsen [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2015-01-15

    In the current paper, dynamic stability analysis of microbeams subjected to piezoelectric voltage is presented in which the microbeam is integrated with piezoelectric layers on the lower and upper surfaces. Both of the flutter and divergence instabilities of microbeams with clamped-clamped and clamped-free boundary conditions are predicted corresponding to various values of applied voltage. To take size effect into account, the classical Timoshenko beam theory in conjunction with strain gradient elasticity theory is utilized to develop nonclassical beam model containing three additional internal length scale parameters. By using Hamilton's principle, the higher-order governing differential equations and associated boundary conditions are derived. Afterward, generalized differential quadrature method is employed to discretize the size-dependent governing differential equations along with clamped-clamped and clamped-free end supports. The critical piezoelectric voltages corresponding to various values dimensionless length scale parameter are evaluated and compared with those predicted by the classical beam theory. It is revealed that in the case of clamped-free boundary conditions, the both of flutter and divergence instabilities occur. However, for the clamped-clamped microbeams, only divergence instability takes place.

  19. Analysis of the role of PCNA-DNA contacts during clamp loading

    Directory of Open Access Journals (Sweden)

    Goedken Eric R

    2010-01-01

    Full Text Available Abstract Background Sliding clamps, such as Proliferating Cell Nuclear Antigen (PCNA in eukaryotes, are ring-shaped protein complexes that encircle DNA and enable highly processive DNA replication by serving as docking sites for DNA polymerases. In an ATP-dependent reaction, clamp loader complexes, such as the Replication Factor-C (RFC complex in eukaryotes, open the clamp and load it around primer-template DNA. Results We built a model of RFC bound to PCNA and DNA based on existing crystal structures of clamp loaders. This model suggests that DNA would enter the clamp at an angle during clamp loading, thereby interacting with positively charged residues in the center of PCNA. We show that simultaneous mutation of Lys 20, Lys 77, Arg 80, and Arg 149, which interact with DNA in the RFC-PCNA-DNA model, compromises the ability of yeast PCNA to stimulate the DNA-dependent ATPase activity of RFC when the DNA is long enough to extend through the clamp. Fluorescence anisotropy binding experiments show that the inability of the mutant clamp proteins to stimulate RFC ATPase activity is likely caused by reduction in the affinity of the RFC-PCNA complex for DNA. We obtained several crystal forms of yeast PCNA-DNA complexes, measuring X-ray diffraction data to 3.0 Å resolution for one such complex. The resulting electron density maps show that DNA is bound in a tilted orientation relative to PCNA, but makes different contacts than those implicated in clamp loading. Because of apparent partial disorder in the DNA, we restricted refinement of the DNA to a rigid body model. This result contrasts with previous analysis of a bacterial clamp bound to DNA, where the DNA was well resolved. Conclusion Mutational analysis of PCNA suggests that positively charged residues in the center of the clamp create a binding surface that makes contact with DNA. Disruption of this positive surface, which had not previously been implicated in clamp loading function, reduces RFC

  20. Umbilical cord blood acid-base and gas analysis after early versus delayed cord clamping in neonates at term.

    Science.gov (United States)

    De Paco, Catalina; Florido, Jesús; Garrido, Mari Carmen; Prados, Sonia; Navarrete, Luis

    2011-05-01

    To compare umbilical cord acid-base status and blood gas analysis between umbilical cords clamped within 10 s and at 2 min of delivery. A total of 158 healthy full-term mothers were randomly assigned to an early clamping (clamping (2 min post-delivery, n = 79) group. After application of inclusion criteria, umbilical vein blood acid-base status and gases were analyzed in 65 early clamped and 51 delayed clamped cords. Fewer cases could be examined in the umbilical artery: 55 cords in the early clamping group and 44 in the delayed one. Acid-base and gas analysis results did not significantly differ between the groups in the umbilical vein or umbilical artery, with the exception of a higher (p umbilical artery pO(2) value in the delayed versus early clamping group. No significant differences in umbilical vein or artery pCO(2) or HCO(3) (-) values were observed between the early and delayed clamp groups. A delay of 2 min before umbilical cord clamping does not significantly change acid-base and gas analysis results, with the exception of a higher mean umbilical artery pO(2) value in the delayed clamping group.

  1. Control Strategy of Two Capacitor Voltages for Separate MPPTs in Photovoltaic Systems Using Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Choi, Ui-Min; Blaabjerg, Frede; Lee, Kyo-Beum

    2015-01-01

    The centralized topology with three-level inverters are widely used in photovoltaic (PV) systems due to their less installation costs and complexity. However, the common maximum power point tracking (MPPT) is a disadvantage of the centralized topology particularly under the partial shading...... and panel mismatch conditions. In this system, if PV modules are separately connected to the split capacitor voltage, the MPPT efficiency can be improved by the proposed control strategy. By the proposed method, the two capacitor voltages can be controlled asymmetrically to perform the separate MPPTs...

  2. Harmonic analysis of DC capacitor current in sinusoidal and space-vector modulated neutral-point-clamped inverters

    Indian Academy of Sciences (India)

    Gopalakrishnan K S; G Narayanan

    2015-08-01

    The voltage ripple and power loss in the DC-capacitor of a voltage source inverter depend on the harmonic currents flowing through the capacitor. This paper presents a double Fourier series based analysis of the harmonic contents of the DC capacitor current in a three-level neutral-point clamped (NPC) inverter, modulated with sine-triangle pulse-width modulation (SPWM) or conventional space vector pulse-width modulation (CSVPWM) schemes. The analytical results are validated experimentally on a 3-kVA three-level inverter prototype. The capacitor current in an NPC inverter has a periodicity of 120º at the fundamental or modulation frequency. Hence, this current contains third-harmonic and triplen-frequency components, apart from switching frequency components. The harmonic components vary with modulation index and power factor for both PWM schemes. The third harmonic current decreases with increase in modulation index and also decreases with increase in power factor in case of both PWM methods. In general, the third harmonic content is higher with SPWM than with CSVPWM at a given operating condition. Also, power loss and voltage ripple in the DC capacitor are estimated for both the schemes using the current harmonic spectrum and equivalent series resistance (ESR) of the capacitor.

  3. Modulation Methods for Neutral-Point-Clamped Wind Power Converter Achieving Loss and Thermal Redistribution Under Low-Voltage Ride-Through

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2014-01-01

    The three-level neutral-point (NP)-clamped (3L-NPC) converter is a promising multilevel topology in the application of megawatt wind power generation systems. However, the growing requirements by grid codes may impose high stress and even give reliability problem to this converter topology....... This paper investigates the loss and thermal performances of a 10-MW 3L-NPC wind power inverter undergoing low-voltage ride-through (LVRT) operation. A series of new space vector modulation methods is then proposed to relocate the thermal loading among the power switching devices. It is concluded that......, with the proposed modulation methods, the thermal distribution in the 3L-NPC wind power inverter undergoing LVRT becomes more equal, and the junction temperature of the most stressed devices can be also relieved. Also, the control ability of the dc-bus NP potential, which is one of the crucial considerations...

  4. Single base pair mutation analysis by PNA directed PCR clamping

    DEFF Research Database (Denmark)

    Ørum, H.; Nielsen, P.E.; Egholm, M.

    1993-01-01

    A novel method that allows direct analysis of single base mutation by the polymerase chain reaction (PCR) is described. The method utilizes the finding that PNAs (peptide nucleic acids) recognize and bind to their complementary nucleic acid sequences with higher thermal stability and specificity...... than the corresponding deoxyribooligonucleotides and that they cannot function as primers for DNA polymerases. We show that a PNA/DNA complex can effectively block the formation of a PCR product when the PNA is targeted against one of the PCR primer sites. Furthermore, we demonstrate that this blockage...... allows selective amplification/suppression of target sequences that differ by only one base pair. Finally we show that PNAs can be designed in such a way that blockage can be accomplished when the PNA target sequence is located between the PCR primers....

  5. Analysis of nematode mechanics by piezoresistive displacement clamp.

    Science.gov (United States)

    Park, Sung-Jin; Goodman, Miriam B; Pruitt, Beth L

    2007-10-30

    Studying animal mechanics is critical for understanding how signals in the neuromuscular system give rise to behavior and how force-sensing organs and sensory neurons work. Few techniques exist to provide forces and displacements appropriate for such studies. To address this technological gap, we developed a metrology using piezoresistive cantilevers as force-displacement sensors coupled to a feedback system to apply and maintain defined load profiles to micrometer-scale animals. We show that this system can deliver forces between 10(-8) and 10(-3) N across distances of up to 100 mum with a resolution of 12 nN between 0.1 Hz and 100 kHz. We use this new metrology to show that force-displacement curves of wild-type nematodes (Caenorhabditis elegans) are linear. Because nematodes have approximately cylindrical bodies, this finding demonstrates that nematode body mechanics can be modeled as a cylindrical shell under pressure. Little is known about the relative importance of hydrostatic pressure and shell mechanics, however. We show that dissipating pressure by cuticle puncture or decreasing it by hyperosmotic shock has only a modest effect on stiffness, whereas defects in the dpy-5 and lon-2 genes, which alter body shape and cuticle proteins, decrease and increase stiffness by 25% and 50%, respectively. This initial analysis of C. elegans body mechanics suggests that shell mechanics dominates stiffness and is a first step in understanding how body mechanics affect locomotion and force sensing.

  6. Comparative Analysis and Simulation of Diode Clamped & Cascaded H-Bridge Multilevel Inverter using SPWM Technique

    Directory of Open Access Journals (Sweden)

    Mohit Jain

    2015-01-01

    Full Text Available Multilevel inverters have become more popular over the years in high power medium voltage applications without the use of a transformer and with promise of less disturbance & reduced harmonic distortion. In this paper, two types of multilevel converter in three phase configuration, cascaded H-Bridge multilevel inverter (CMLI and diode clamped multilevel inverter (DCMLI of 5 and 7-level are modelled and compared in the case of feeding of a three phase squirrel cage induction motor. Here, carrier based sinusoidal pulse width modulation (SPWM technique is used as the modulation strategy. These modulation strategy include phase disposition technique (PD, phase opposition disposition technique (POD, and an alternative phase opposition disposition technique (APOD. A detailed study of the modulation technique has been carried out through MATLAB/SIMULINK for both multilevel converters and a comparative evaluation between DCMLI and CMLI using SPWM technique in terms of THD%.

  7. Perforated patch-clamp analysis of the passive membrane properties of three classes of hippocampal neurons.

    Science.gov (United States)

    Spruston, N; Johnston, D

    1992-03-01

    1. Perforated patch-clamp recordings were made from the three major classes of hippocampal neurons in conventional in vitro slices prepared from adult guinea pigs. This technique provided experimental estimates of passive membrane properties (input resistance, RN, and membrane time constant, tau m) determined in the absence of the leak conductance associated with microelectrode impalement or the washout of cytoplasmic constituents associated with conventional whole-cell recordings. 2. To facilitate comparison of our data with previous results and to determine the passive membrane properties under conditions as physiological as possible, recordings were made at the resting potential, in physiological saline, and without any added blockers of voltage-dependent conductances. 3. Membrane-potential responses to current steps were analyzed, and four criteria were used to identify voltage responses that were the least affected by activation of voltage-dependent conductances. tau m was estimated from the slowest component (tau 0) of multiexponential fits of responses deemed passive by these criteria. RN was estimated from the slope of the linear region in the hyperpolarizing direction of the voltage-current relation. 4. It was not possible to measure purely passive membrane properties that were completely independent of membrane potential in any of the three classes of hippocampal neurons. Changing the membrane potential by constant current injection resulted in changes in RN and tau 0; subthreshold depolarization produced an increase, and hyperpolarization a decrease, in both RN and tau 0 for all three classes of hippocampal neurons. 5. Each of the three classes of hippocampal neurons also displayed a depolarizing "sag" during larger hyperpolarizing voltage transients. To evaluate the effect of the conductances underlying this sag on passive membrane properties, 2-5 mM Cs+ was added to the physiological saline. Extracellular Cs+ effectively blocked the sag in all three

  8. Surface analysis of anodized aluminum clamps from NASA-LDEF satellite

    Science.gov (United States)

    Grammer, H. L.; Wightman, J. P.; Young, Philip R.

    1992-01-01

    Surface analysis results of selected anodized aluminum clamps containing black (Z306) and white (A276) paints which received nearly six years of Low Earth Orbit (LEO) exposure on the Long Duration Exposure Facility are reported. Surface analytical techniques, including x-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and scanning electron microscopy/energy dispersive analysis by x-ray (SEM/EDAX), showed significant differences in the surface composition of these materials depending upon the position on the LDEF. Differences in the surface composition are attributed to varying amounts of atomic oxygen and vacuum ultraviolet radiation (VUV). Silicon containing compounds were the primary contaminant detected on the materials.

  9. Unloaded speed of shortening in voltage-clamped intact skeletal muscle fibers from wt, mdx, and transgenic minidystrophin mice using a novel high-speed acquisition system.

    Science.gov (United States)

    Friedrich, O; Weber, C; von Wegner, F; Chamberlain, J S; Fink, R H A

    2008-06-01

    Skeletal muscle unloaded shortening has been indirectly determined in the past. Here, we present a novel high-speed optical tracking technique that allows recording of unloaded shortening in single intact, voltage-clamped mammalian skeletal muscle fibers with 2-ms time resolution. L-type Ca(2+) currents were simultaneously recorded. The time course of shortening was biexponential: a fast initial phase, tau(1), and a slower successive phase, tau(2,) with activation energies of 59 kJ/mol and 47 kJ/mol. Maximum unloaded shortening speed, v(u,max), was faster than that derived using other techniques, e.g., approximately 14.0 L(0) s(-1) at 30 degrees C. Our technique also allowed direct determination of shortening acceleration. We applied our technique to single fibers from C57 wild-type, dystrophic mdx, and minidystrophin-expressing mice to test whether unloaded shortening was affected in the pathophysiological mechanism of Duchenne muscular dystrophy. v(u,max) and a(u,max) values were not significantly different in the three strains, whereas tau(1) and tau(2) were increased in mdx fibers. The results were complemented by myosin heavy and light chain (MLC) determinations that showed the same myosin heavy chain IIA profiles in the interossei muscles from the different strains. In mdx muscle, MLC-1f was significantly increased and MLC-2f and MLC-3f somewhat reduced. Fast initial active shortening seems almost unaffected in mdx muscle.

  10. Conformational analysis of processivity clamps in solution demonstrates that tertiary structure does not correlate with protein dynamics.

    Science.gov (United States)

    Fang, Jing; Nevin, Philip; Kairys, Visvaldas; Venclovas, Ceslovas; Engen, John R; Beuning, Penny J

    2014-04-08

    The relationship between protein sequence, structure, and dynamics has been elusive. Here, we report a comprehensive analysis using an in-solution experimental approach to study how the conservation of tertiary structure correlates with protein dynamics. Hydrogen exchange measurements of eight processivity clamp proteins from different species revealed that, despite highly similar three-dimensional structures, clamp proteins display a wide range of dynamic behavior. Differences were apparent both for structurally similar domains within proteins and for corresponding domains of different proteins. Several of the clamps contained regions that underwent local unfolding with different half-lives. We also observed a conserved pattern of alternating dynamics of the α helices lining the inner pore of the clamps as well as a correlation between dynamics and the number of salt bridges in these α helices. Our observations reveal that tertiary structure and dynamics are not directly correlated and that primary structure plays an important role in dynamics.

  11. 多电平变换器直流侧电压平衡控制电路%DC Bus Capacitor Voltage Balancing Circuits in Diode-Clamped Multilevel Converter

    Institute of Scientific and Technical Information of China (English)

    丁娜; 舒泽亮

    2014-01-01

    为解决二极管箝位型多电平变换器直流侧电容电压不平衡的问题,设计了一种带二级辅助电感的平衡控制电路,通过简单控制可以平衡多电平变换器直流侧所有电容的电压。在分析电路结构和控制原理的基础上,从能量转换的角度出发,给出了辅助电感参数选择的范围。以五电平变换器为研究对象,建立了Matlab/Simulink仿真模型,搭建了实验样机,对比分析了本文平衡电路与传统一级平衡控制电路的电容电压平衡特性。实验结果表明,当二级辅助电路工作时,所有直流侧电容电压在20 ms内达到平衡,电容电压的纹波小于3%。%In order to solve the imbalance of DC bus capacitor voltages in the diode-clamped multilevel converter,a balancing circuit with two-layer auxiliary inductors was designed. With this circuit,the voltages of all the DC-side capacitors in the multilevel converter can be balanced by a simple control. On the basis of analysis of the circuit structure and control principle,the ranges of inductor parameters were analyzed from the viewpoint of energy conversion. Taking a five-level converter as an example,a Matlab/Simulink simulation model and an experimental prototype were built,and the balance characteristics of DC bus capacitor voltages were compared between the proposed two-layer auxiliary circuit and the traditional one-layer circuit. Experimental results verify that the proposed two-layer circuit could effectively balance all the DC bus capacitor voltages within 20 ms,and the capacitor voltage ripple was less than 3%.

  12. Does clamping during liver surgery predispose to thrombosis of the hepatic veins? Analysis of 210 cases

    Institute of Scientific and Technical Information of China (English)

    Nikolaos Arkadopoulos; Vaia Stafyla; Athanasios Marinis; Vassilios Koutoulidis; Kassiani Theodoraki; Theodosios Theodosopoulos; Ioannis Vassiliou; Nikolaos Dafnios; Georgios Fragulidis; Vassilios Smyrniotis

    2009-01-01

    AIM: To test whether clamping during liver surgery predisposes to hepatic vein thrombosis.METHODS: We performed a retrospective analysis of 210 patients who underwent liver resection with simultaneous inflow and outflow occlusion.Intraoperatively, flow in the hepatic veins was assessed by Doppler ultrasonography during the reperfusion phase. Postoperatively, patency of the hepatic veins was assessed by contrast-enhanced CT angiography,when necessary after 3-6 mo follow up.RESULTS: Twelve pat ients (5.7%) developed intraoperative liver remnant swelling. However,intraoperative ultrasonography did not reveal evidence of hepatic vein thrombosis. In three of these patients a kinking of the common trunk of the middle and left hepatic veins hindering outflow was recognized and was managed successfully by suturing the liver remnant to the diaphragm. Twenty three patients (10.9%) who developed signs of mild outflow obstruction postoperatively, had no evidence of thrombi in the hepatic veins or flow disturbances on ultrasonography and contrast-enhanced CT angiography, while hospitalized. Long term assessment of the patency of the hepatic veins over a 3-6 mo follow-up period did not reveal thrombi formation or clinical manifestations of outflow obstruction.CONCLUSION: Extrahepatic dissection and clamping of the hepatic veins does not predispose to clinically important thrombosis.

  13. 一种新型自均压二极管钳位级联有源滤波器%A Novel Voltage Self-balance Diode-clamped Cascaded Multilevel Active Power Filter

    Institute of Scientific and Technical Information of China (English)

    高聪哲; 姜新建; 李永东

    2012-01-01

    A novel diode-clamped cascaded multilevel converter topology is proposed. The half bridge cascade cell is added a clamping diode to the DC-link capacitor, and it may provide an energy channel clamping in single direction for capacitor voltage. Via the clamping diodes, only the top and bottom cells of a phase arm need to be controlled to realize each cell' s capacitors voltage balance. Therefore, the DC-link voltage sensors of a phase arm are reduced to two, much less than that of traditional cascaded converter. A three-phase multilevel active power filter (APF) topology based on the proposed diode clamped cascaded multilevel converter topology is provided, and its control strategy is presented as well. A simulation model and an experiment prototype of seven-level diode-clamped cascaded multilevel APF are built. The simulation and experiment results show that the novel cascaded multilevel converter topology has good performance in voltage selbbalance control and harmonics compensation, and the control algorithm is easy and feasible.%提出一种新型二极管钳位级联多电平拓扑,在半桥单元拓扑上增加钳位二极管,为直流电容提供单向钳位通路。在该拓扑中,只需对阀体两端单元的直流电压进行控制就可实现均压控制,且每相阀体只需2个直流电压传感器,结构简单。将拓扑拓展到三相结构,提出了二极管钳位多电平有源滤波器(APF)拓扑及其控制方法。搭建了7电平二极管钳位多电平APF仿真模型和实验样机。实验结果表明,该拓扑自均压控制和谐波补偿效果良好,控制算法简易、可行。

  14. Dynamic Analysis of Power System Voltage Stability.

    Science.gov (United States)

    Gebreselassie, Assefa

    This thesis investigates the effects of loads and voltage regulators on the dynamic voltage stability of power systems. The analysis focuses on the interactions of machine flux dynamics with loads and voltage control devices. The results are based on eigenvalue analysis of the linearized models and time simulation of the nonlinear models, using models from the Power System Toolbox, a Matlab -based package for the simulation and small signal analysis of nonlinear power systems. The voltage stability analysis results are developed using a single machine single load system with typical machine and network parameters and the NPCC 10-machine system. Dynamic models for generators, exciters and loads are used. The generator is modeled with a pair of poles and one damper circuit in both the d-axis and the q-axis. Saturation effects are included in the model. The IEEE Type DC1 DC commutator exciter model is used for all the exciters. Five different types of loads: constant impedance, constant current, constant power, a first order induction motor model (slip model) and a third order induction motor model (slip-flux model) are considered. The modes of instability and the stability limits of the different representation of loads are examined for two different operating modes of the exciters. The first, when all the exciters are on automatic control and the second when some exciters are on manual control. Modal participation factors are used to determine the characteristics of the critical modes. The characteristics of the unstable modes are verified by performing time simulation of the nonlinear models. Oscillatory and non-oscillatory instabilities are experienced by load buses when all the exciters are on automatic control and some exciters are on manual control respectively, for loads which are predominantly constant power and induction motors. It is concluded that the mode of instability does not depend on the type of loads but on the operating condition of the exciters

  15. A systematic review and meta-analysis of a brief delay in clamping the umbilical cord of preterm infants.

    Science.gov (United States)

    Rabe, Heike; Reynolds, Graham; Diaz-Rossello, Jose

    2008-01-01

    The optimal timing of clamping the umbilical cord in preterm infants at birth is the subject of continuing debate. To investigate the effects of a brief delay in cord clamping on the outcome of babies born prematurely. A retrospective meta-analysis of randomised trials in preterm infants was conducted. Data were collected from published studies identified by a structured literature search in EMBASE, PubMed, CINAHL and the Cochrane Library. All infants born below 37 weeks gestation and enrolled into a randomised study of delayed cord clamping (30 s or more) versus immediate cord clamping (less than 20 s) after birth were included. Systematic search and analysis of the data were done according to the methodology of the Cochrane collaboration. Ten studies describing a total of 454 preterm infants were identified which met the inclusion and assessment criteria. Major benefits of the intervention were higher circulating blood volume during the first 24 h of life, less need for blood transfusions (p = 0.004) and less incidence of intraventricular hemorrhage (p = 0.002). The procedure of a delayed cord clamping time of at least 30 s is safe to use and does not compromise the preterm infant in the initial post-partum adaptation phase. (c) 2007 S. Karger AG, Basel

  16. A new configuration for multilevel converters with diode clamped topology

    DEFF Research Database (Denmark)

    Nami, A.; Zare, F.; Ledwich, G.

    2008-01-01

    of load changes which can avoid neutral point balancing problem in such converters. In addition, the presented topology is suitable for renewable energy systems to boost the low rectified output-voltage. In order to verify the proposed topology, steady state analysis, modelling and simulations are carried......Due to the increased use of renewable energy and power elctronic applications, more multilevel converters (MLC) are developed. A Neutral Point Clamped (NPC) inverter is one of the most used multilevel topologies for wind turbine (WT) and photovoltaic (PV) applications. One of the most crucial...... points in this type of converter is dc-voltage control. In this paper, a novel multi output dc-dc converter connected to a diode clamped topology is presented. This converter, for a given duty cycles, is able to regulate the capacitor voltage to provide an appropriate input voltage for NPC regardless...

  17. SCBUCKLE user's manual: Buckling analysis program for simple supported and clamped panels

    Science.gov (United States)

    Cruz, Juan R.

    1993-01-01

    The program SCBUCKLE calculates the buckling loads and mode shapes of cylindrically curved, rectangular panels. The panel is assumed to have no imperfections. SCBUCKLE is capable of analyzing specially orthotropic symmetric panels (i.e., A(sub 16) = A(sub 26) = 0.0, D(sub 16) = D(sub 26) = 0.0, B(sub ij) = 0.0). The analysis includes first-order transverse shear theory and is capable of modeling sandwich panels. The analysis supports two types of boundary conditions: either simply supported or clamped on all four edges. The panel can be subjected to linearly varying normal loads N(sub x) and N(sub y) in addition to a constant shear load N(sub xy). The applied loads can be divided into two parts: a preload component; and a variable (eigenvalue-dependent) component. The analysis is based on the modified Donnell's equations for shallow shells. The governing equations are solved by Galerkin's method.

  18. RICH High Voltages & PDF Analysis @ LHCb

    CERN Multimedia

    Fanchini, E

    2009-01-01

    In the LHCb experiment an important issue is the identification of the hadrons of the final states of the B mesons decays. Two RICH subdetectors are devoted to this task, and the Hybrid Photon Detectors (HPDs) are the photodetectors used to detect Cherenkov light. In this poster there is a description of how the very high voltage (-18 KV) supply stability used to power the HPDs is monitored. It is also presented the basics of a study which can be done with the first collision data: the analysis of the dimuons from the Drell-Yan process. This process is well known and the acceptance of the LHCb detector in terms of pseudorapidity will be very useful to improve the knowledge of the proton structure functions or, alternatively, try to estimate the luminosity from it.

  19. The Analysis of Clamping Mechanism Theory and the Application Design of Tobacco Leaves'Clamping Tool%夹紧机构的理论分析及烘烤烟叶夹的应用设计

    Institute of Scientific and Technical Information of China (English)

    徐远龙; 孙有祥

    2011-01-01

    In view of the complicated manual skill of the tobacco leaf weaving, the study and design of a kind tool clamping tobacco leaf is proposed by our actual investigation; According to the predetermined function demand and the available clamping mechanism, the principle of the clamping tool is studied out, the structural design scheme of the clamping tool is worked out and the clamping tool is made by the theory analysis of mechanism design and the study of clamping mechanism. The clamping tool tested by the surveyor is good in use, which is welcome to use by the peasants and the economy benefit of the market can be achieved highly.%通过对烟叶烘烤生产工艺的实际调研,针对手工繁杂的编烟技术,提出了研究设计一种烘烤烟叶夹持工具;针对烘烤烟叶夹的预定功能要求,参考现有的实用夹紧机构,通过对机械产品机构设计的理论分析和夹紧机构的力学研究,确定了夹紧烟叶的力学原理,提出了烘烤烟叶夹的结构设计方案,设计制造出烘烤烟叶夹;该烘烤烟叶夹通过了产品的质量检测,使用效果良好,烟农用户普遍接受使用,预计有较高的市场经济效益.

  20. Intraoperative forces and moments analysis on patient head clamp during awake brain surgery.

    Science.gov (United States)

    De Lorenzo, Danilo; De Momi, Elena; Conti, Lorenzo; Votta, Emiliano; Riva, Marco; Fava, Enrica; Bello, Lorenzo; Ferrigno, Giancarlo

    2013-03-01

    In brain surgery procedures, such as deep brain stimulation, drug-resistant epilepsy and tumour surgery, the patient is intentionally awakened to map functional neural bases via electrophysiological assessment. This assessment can involve patient's body movements; thus, increasing the mechanical load on the head-restraint systems used for keeping the skull still during the surgery. The loads exchanged between the head and the restraining device can potentially result into skin and bone damage. The aim of this work is to assess such loads for laying down the requirements of a surgical robotics system for dynamic head movements compensation by fast moving arms and by an active restraint able to damp such actions. A Mayfield(®) head clamp was tracked and instrumented with strain gages (SGs). SG locations were chosen according to finite element analyses. During an actual brain surgery, displacements and strains were measured and clustered according to events that generated them. Loads were inferred from strain data. The greatest force components were exerted vertically (median 5.5 N, maximum 151.87 N) with frequencies up to 1.5 Hz. Maximum measured displacement and velocity were 9 mm and 60 mm/s, with frequencies up to 2.8 Hz. The analysis of loads and displacements allowed to identify the surgery steps causing maximal loads on the head-restraint device.

  1. Design and analysis of different trigger techniques for ESD clamp circuit in 0.5-µm 5 V/18 V CDMOS process

    Science.gov (United States)

    Zhang, Wenjie; Yang, Liu; Wang, Yang; Jin, Xiangliang

    2017-09-01

    In this work, gate-driven, substrate-triggered and gate-substrate-triggered techniques for both 5 V NMOS-based and 18 V NLDMOS-based power clamps under electrostatic discharge (ESD) stress were investigated in details. Schematics of the three trigger designs were depicted and their physical mechanisms were studied at first. To verify and make comparisons of their performance, they were fabricated in a standard 0.5-μm 5 V/18 V CDMOS process and characterized by transmission line pulse (TLP) test system, respectively. Experimental results show that 5 V NMOS-based power clamp with substrate-triggered technique has the lowest trigger voltage (∼8.37 V) and the highest failure current (∼3.58 A), and 18 V gate-substrate-triggered design based on NLDMOS has low trigger voltage (∼34.02 V) and greatest robustness (It2 = 3.32 A). Therefore, as for low-voltage NMOS-based ESD power clamps, substrate-triggered design obtains the most superior ESD protection performance; but for high-voltage power clamps, gate-substrate-triggered technique can make NLDMOS actualize uniform current conduction and better ESD robustness.

  2. Analysis of a Three-Level LLC Series Resonant Converter for High- and Wide-Input-Voltage Applications

    Directory of Open Access Journals (Sweden)

    S.Saravanan

    2014-04-01

    Full Text Available In this paper, the analysis of a three-level LLC series resonant converter (TL LLC SRC for high- and wide input-voltage applications is presented. It consists of two half-bridge LLC SRCs in series, sharing a resonant inductor and a transformer. Its main advantages are that the voltage across each switch is clamped at half of the input voltage and that voltage balance is achieved and simple driving signals . Thus it is suitable for high-inputvoltage applications. Based on the results of these analyses, a design example is provided and its validity is confirmed by an experiment involving a prototype converter with an input of 600V and an output of 48 V/20 A.

  3. Development of planar patch clamp technology and its application in the analysis of cellular electrophysiology

    Institute of Scientific and Technical Information of China (English)

    Peihua Chen; Wei Zhang; Jun Zhou; Ping Wang; Lidan Xiao; Mo Yang

    2009-01-01

    A patch clamp chip, as a novel cell-based chip for electrophysiological recordings, has many prominent advantages such as high res-olution, accuracy, high throughput and automation. It can be used to perform multivariate and real-time measurements of cell networks in situ. Therefore, this technology will dramatically promote the research on ionic channels, neuronal networks and the application of this technology in drug screening. This paper reviews the development of planar patch clamp technology and its applications in detail. The latest progress in the research of taste cells electrophysiology and taste transduction is also presented. Finally, this paper analyzes the methodology of neural chips. Based on the current research of our laboratory, the prospective applications of a patch clamp chip in the research of taste sensation and transduction mechanisms at molecular and cellular levels are discussed.

  4. Method to minimize the low-frequency neutral-point voltage oscillations with time-offset injection for neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, Kyo-Beum; Blaabjerg, Frede

    2013-01-01

    This paper proposes a method to reduce the low-frequency neutral-point voltage oscillations. The neutral-point voltage oscillations are considerably reduced by adding a time-offset to the three phase turn-on times. The proper time-offset is simply calculated considering the phase currents and dwell...

  5. Method to Minimize the Low-Frequency Neutral-Point Voltage Oscillations With Time-Offset Injection for Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Choi, Ui-Min; Blaabjerg, Frede; Lee, Kyo-Beum

    2015-01-01

    This paper proposes a method to reduce the low-frequency neutral-point voltage oscillations. The neutral-point voltage oscillations are considerably reduced by adding a time offset to the three-phase turn-on times. The proper time offset is simply calculated considering the phase currents and dwell...

  6. Characterization of a patch-clamp microchannel array towards neuronal networks analysis

    DEFF Research Database (Denmark)

    Alberti, Massimo; Snakenborg, Detlef; Lopacinska, Joanna M.

    2010-01-01

    for simultaneous patch clamping of cultured cells or neurons in the same network. A disposable silicon/silicon dioxide (Si/SiO2) chip with a microhole array was integrated in a microfluidic system for cell handling, perfusion and electrical recording. Fluidic characterization showed that our PC mu CA can work...

  7. Thermal and Efficiency Analysis of Five-Level Multilevel-Clamped Multilevel Converter Considering Grid Codes

    DEFF Research Database (Denmark)

    Ma, Ke; Muñoz-Aguilar, R. S.; Rodriguez, Pedro;

    2014-01-01

    In this paper, a five-level multilevel-clamped multilevel converter (5L- MLC2) topology is analyzed based on a typical grid integration application for renewable energy system. The loss and thermal distributions of the power devices in different switching legs are investigated and illustrated und...

  8. Experimental and numerical analysis of clamped joints in front motorbike suspensions

    Directory of Open Access Journals (Sweden)

    Vincenzi N.

    2010-06-01

    Full Text Available Clamped joints are shaft-hub connections used, as an instance, in front motorbike suspensions to lock the steering plates with the legs and the legs with the wheel pin, by means of one or two bolts. The preloading force, produced during the tightening process, should be evaluated accurately, since it must lock safely the shaft, without overcoming the yielding point of the hub. Firstly, friction coefficients have been evaluated on “ad-hoc designed” specimens, by applying the Design of Experiment approach: the applied tightening torque has been precisely related to the imposed preloading force. Then, the tensile state of clamps have been evaluated both via FEM and by leveraging some design formulae proposed by the Authors as function of the preloading force and of the clamp geometry. Finally, the results have been compared to those given by some strain gauges applied on the tested clamps: the discrepancies between numerical analyses, the design formulae and the experimental results remains under a threshold of 10%.

  9. Improved non-dimensional dynamic influence function method for vibration analysis of arbitrarily shaped plates with clamped edges

    Directory of Open Access Journals (Sweden)

    Sang-Wook Kang

    2016-03-01

    Full Text Available A new formulation for the non-dimensional dynamic influence function method, which was developed by the authors, is proposed to efficiently extract eigenvalues and mode shapes of clamped plates with arbitrary shapes. Compared with the finite element and boundary element methods, the non-dimensional dynamic influence function method yields highly accurate solutions in eigenvalue analysis problems of plates and membranes including acoustic cavities. However, the non-dimensional dynamic influence function method requires the uneconomic procedure of calculating the singularity of a system matrix in the frequency range of interest for extracting eigenvalues because it produces a non-algebraic eigenvalue problem. This article describes a new approach that reduces the problem of free vibrations of clamped plates to an algebraic eigenvalue problem, the solution of which is straightforward. The validity and efficiency of the proposed method are illustrated through several numerical examples.

  10. Conformal analysis of fundamental frequency of vibration of elastic clamped plates

    Institute of Scientific and Technical Information of China (English)

    QI Hongyuan; ZHU Hengjun

    2007-01-01

    To calculate the fundamental frequency of vibration of special-shaped and elastic clamped plates, the conformal mapping theory is adopted to separate the interpolating points of a complicated boundary into odd and even sequences,both of which can be mutually iterated, so that the conformal mapping function between the complicated region and the unit dish region is established. Trigonometric interpolation and convergence along the normal direction methods are provided, and the complex coefficients of the conformal mapping function are calculated. Galerkin method is used to obtain the solution of fundamental frequency in the vibrating differential function of the complicated vibrating region.Finally, taking ellipse elastic clamped plates as an example,the effects on fundamental frequency coefficient caused by eccentric ratio e and area size are analyzed.

  11. Low noise patch-clamp current amplification by nanoparticles plasmonic-photonic coupling (analysis and modelling).

    Science.gov (United States)

    Haberal, E O; SalmanOgli, A; Nasseri, B

    2016-10-01

    In this article, a patch-clamp low noise current amplification based on nanoparticles plasmonic radiation is analyzed. It is well-known, a very small current is flowing from different membrane channels and so, for extra processing the current amplification is necessary. It is notable that there are some problems in traditional electronic amplifier due to its noise and bandwidth problem. Because of the important role of the patch-clamp current in cancer research and especially its small amplitude, it is vital to intensify it without adding any noises. In this study, the current amplification is performed firstly: from the excitement of nanoparticles by the patch-clamp pico-ampere current and then, the effect of nanoparticles plasmonic far-field radiation on conductor's carriers, which will cause the current amplification. This relates to the plasmonic-photonic coupling and their effect on conductor carriers as the current perturbation agent. In the steady state, the current amplification can reach to 1000 times of initial level. Furthermore, we investigated the nanoparticles morphology changing effect such as size, nanoparticles inter-distance, and nanoparticles distance from the conductor on the amplifier parameters. Finally, it should note that the original aim is to use nanoparticles plasmonic engineering and their coupling to photonics for output current manipulating.

  12. Analysis of failed and nickel-coated 3093 beam clamp components at the East Tennessee Technology Park (ETTP).

    Energy Technology Data Exchange (ETDEWEB)

    Singh, D.; Pappacena, K.; Gaviria, J.; Burtsteva, T.; Nuclear Engineering Division

    2010-10-11

    The U.S. Department of Energy and its contractor, Bechtel Jacobs Company (BJC), are undertaking a major effort to clean up the former gaseous diffusion facility (K-25) located in Oak Ridge, TN. The decontamination and decommissioning activities require systematic removal of contaminated equipment and machinery followed by demolition of the buildings. As part of the cleanup activities, a beam clamp, used for horizontal life lines (HLLs) for fall protection, was discovered to be fractured during routine inspection. The beam clamp (yoke and D-ring) was a component in the HLL system purchased from Reliance Industries LLC. Specifically, the U-shaped stainless steel yoke of the beam clamp failed in a brittle mode at under less than 10% of the rated design capacity of 14,500 lb. The beam clamp had been in service for approximately 16 months. Bechtel Jacobs approached Argonne National Laboratory to assist in identifying the root cause of the failure of the beam clamp. The objectives of this study were to (1) review the prior reports and documents on the subject, (2) understand the possible failure mechanism(s) that resulted in the failed beam clamp components, (3) recommend approaches to mitigate the failure mechanism(s), and (4) evaluate the modified beam clamp assemblies. Energy dispersive x-ray analysis and chemical analysis of the corrosion products on the failed yoke and white residue on an in-service yoke indicated the presence of zinc, sulfur, and calcium. Analysis of rainwater in the complex, as conducted by BJC, indicated the presence of sulfur and calcium. It was concluded that, as a result of galvanic corrosion, zinc from the galvanized components of the beam clamp assembly (D-ring) migrated to the corroded region in the presence of the rainwater. Under mechanical stress, the corrosion process would have accelerated, resulting in the catastrophic failure of the yoke. As suggested by Bechtel Jacobs personnel, hydrogen embrittlement as a consequence of corrosion

  13. Loss and thermal redistributed modulation methods for three-level neutral-point-clamped wind power inverter undergoing Low Voltage Ride Through

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2012-01-01

    investigates the loss and thermal performances of a 10 MW 3L-NPC wind power inverter undergoing Low Voltage Ride Through (LVRT) operation. A series of new space vector modulation methods are then proposed to relocate the thermal loading among the power switching devices. It is concluded that, with the proposed...

  14. Measurement and analysis of postsynaptic potentials using a novel voltage-deconvolution method.

    Science.gov (United States)

    Richardson, Magnus J E; Silberberg, Gilad

    2008-02-01

    Accurate measurement of postsynaptic potential amplitudes is a central requirement for the quantification of synaptic strength, dynamics of short-term and long-term plasticity, and vesicle-release statistics. However, the intracellular voltage is a filtered version of the underlying synaptic signal and so a method of accounting for the distortion caused by overlapping postsynaptic potentials must be used. Here a voltage-deconvolution technique is demonstrated that defilters the entire voltage trace to reveal an underlying signal of well-separated synaptic events. These isolated events can be cropped out and reconvolved to yield a set of isolated postsynaptic potentials from which voltage amplitudes may be measured directly-greatly simplifying this common task. The method also has the significant advantage of providing a higher temporal resolution of the dynamics of the underlying synaptic signal. The versatility of the method is demonstrated by a variety of experimental examples, including excitatory and inhibitory connections to neurons with passive membranes and those with activated voltage-gated currents. The deconvolved current-clamp voltage has many features in common with voltage-clamp current measurements. These similarities are analyzed using cable theory and a multicompartment cell reconstruction, as well as direct comparison to voltage-clamp experiments.

  15. Voltage stability analysis in the new deregulated environment

    Science.gov (United States)

    Zhu, Tong

    Nowadays, a significant portion of the power industry is under deregulation. Under this new circumstance, network security analysis is more critical and more difficult. One of the most important issues in network security analysis is voltage stability analysis. Due to the expected higher utilization of equipment induced by competition in a power market that covers bigger power systems, this issue is increasingly acute after deregulation. In this dissertation, some selected topics of voltage stability analysis are covered. In the first part, after a brief review of general concepts of continuation power flow (CPF), investigations on various matrix analysis techniques to improve the speed of CPF calculation for large systems are reported. Based on these improvements, a new CPF algorithm is proposed. This new method is then tested by an inter-area transaction in a large inter-connected power system. In the second part, the Arnoldi algorithm, the best method to find a few minimum singular values for a large sparse matrix, is introduced into the modal analysis for the first time. This new modal analysis is applied to the estimation of the point of voltage collapse and contingency evaluation in voltage security assessment. Simulations show that the new method is very efficient. In the third part, after transient voltage stability component models are investigated systematically, a novel system model for transient voltage stability analysis, which is a logical-algebraic-differential-difference equation (LADDE), is offered. As an example, TCSC (Thyristor controlled series capacitors) is addressed as a transient voltage stabilizing controller. After a TCSC transient voltage stability model is outlined, a new TCSC controller is proposed to enhance both fault related and load increasing related transient voltage stability. Its ability is proven by the simulation.

  16. Soft computing techniques in voltage security analysis

    CERN Document Server

    Chakraborty, Kabir

    2015-01-01

    This book focuses on soft computing techniques for enhancing voltage security in electrical power networks. Artificial neural networks (ANNs) have been chosen as a soft computing tool, since such networks are eminently suitable for the study of voltage security. The different architectures of the ANNs used in this book are selected on the basis of intelligent criteria rather than by a “brute force” method of trial and error. The fundamental aim of this book is to present a comprehensive treatise on power system security and the simulation of power system security. The core concepts are substantiated by suitable illustrations and computer methods. The book describes analytical aspects of operation and characteristics of power systems from the viewpoint of voltage security. The text is self-contained and thorough. It is intended for senior undergraduate students and postgraduate students in electrical engineering. Practicing engineers, Electrical Control Center (ECC) operators and researchers will also...

  17. Static Voltage Stability Analysis by Using SVM and Neural Network

    Directory of Open Access Journals (Sweden)

    Mehdi Hajian

    2013-01-01

    Full Text Available Voltage stability is an important problem in power system networks. In this paper, in terms of static voltage stability, and application of Neural Networks (NN and Supported Vector Machine (SVM for estimating of voltage stability margin (VSM and predicting of voltage collapse has been investigated. This paper considers voltage stability in power system in two parts. The first part calculates static voltage stability margin by Radial Basis Function Neural Network (RBFNN. The advantage of the used method is high accuracy in online detecting the VSM. Whereas the second one, voltage collapse analysis of power system is performed by Probabilistic Neural Network (PNN and SVM. The obtained results in this paper indicate, that time and number of training samples of SVM, are less than NN. In this paper, a new model of training samples for detection system, using the normal distribution load curve at each load feeder, has been used. Voltage stability analysis is estimated by well-know L and VSM indexes. To demonstrate the validity of the proposed methods, IEEE 14 bus grid and the actual network of Yazd Province are used.

  18. Force-clamp analysis techniques reveal stretched exponential unfolding kinetics in ubiquitin

    CERN Document Server

    Lannon, Herbert; Brujic, Jasna

    2012-01-01

    Force-clamp spectroscopy reveals the unfolding and disulfide bond rupture times of single protein molecules as a function of the stretching force, point mutations and solvent conditions. The statistics of these times reveal whether the protein domains are independent of one another, the mechanical hierarchy in the polyprotein chain, and the functional form of the probability distribution from which they originate. It is therefore important to use robust statistical tests to decipher the correct theoretical model underlying the process. Here we develop multiple techniques to compare the well-established experimental data set on ubiquitin with existing theoretical models as a case study. We show that robustness against filtering, agreement with a maximum likelihood function that takes into account experimental artifacts, the Kuiper statistic test and alignment with synthetic data all identify the Weibull or stretched exponential distribution as the best fitting model. Our results are inconsistent with recently ...

  19. Power flow analysis for DC voltage droop controlled DC microgrids

    DEFF Research Database (Denmark)

    Li, Chendan; Chaudhary, Sanjay; Dragicevic, Tomislav

    2014-01-01

    This paper proposes a new algorithm for power flow analysis in droop controlled DC microgrids. By considering the droop control in the power flow analysis for the DC microgrid, when compared with traditional methods, more accurate analysis results can be obtained. The algorithm verification...... is carried out by comparing the calculation results with detailed time domain simulation results. With the droop parameters as variables in the power flow analysis, their effects on power sharing and secondary voltage regulation can now be analytically studied, and specialized optimization in the upper level...... control can also be made accordingly. Case studies on power sharing and secondary voltage regulation are carried out using proposed power flow analysis....

  20. To clamp or not to clamp late?

    Directory of Open Access Journals (Sweden)

    Nicoletta Iacovidou

    2013-04-01

    Full Text Available When resuscitating a neonate, one encounters controversial issues and a great deal of confusion. These issues include the question as to when should the umbilical cord be clamped. Clamping and cutting the umbilical cord at birth is the oldest intervention in humans. Even though many aspects of the timing for cord clamping have been clarified, some questions still remain unanswered. If delayed cord clamping is to become a standard approach which timing is the optimal? And depending on the mode of delivery should timing be the same or different for normal vaginal delivery or for caesarean section? What about  the compromised neonate, or the very preterm one? We have more questions than answers. More randomized controlled studies are needed in normal and pathologic neonates, in order to address these questions, before we practice delayed cord clamping with safety for the babies and the mothers.

  1. Eigensensitivity analysis of rotating clamped uniform beams with the asymptotic numerical method

    Science.gov (United States)

    Bekhoucha, F.; Rechak, S.; Cadou, J. M.

    2016-12-01

    In this paper, free vibrations of a rotating clamped Euler-Bernoulli beams with uniform cross section are studied using continuation method, namely asymptotic numerical method. The governing equations of motion are derived using Lagrange's method. The kinetic and strain energy expression are derived from Rayleigh-Ritz method using a set of hybrid variables and based on a linear deflection assumption. The derived equations are transformed in two eigenvalue problems, where the first is a linear gyroscopic eigenvalue problem and presents the coupled lagging and stretch motions through gyroscopic terms. While the second is standard eigenvalue problem and corresponds to the flapping motion. Those two eigenvalue problems are transformed into two functionals treated by continuation method, the Asymptotic Numerical Method. New method proposed for the solution of the linear gyroscopic system based on an augmented system, which transforms the original problem to a standard form with real symmetric matrices. By using some techniques to resolve these singular problems by the continuation method, evolution curves of the natural frequencies against dimensionless angular velocity are determined. At high angular velocity, some singular points, due to the linear elastic assumption, are computed. Numerical tests of convergence are conducted and the obtained results are compared to the exact values. Results obtained by continuation are compared to those computed with discrete eigenvalue problem.

  2. Delayed umbilical cord clamping in premature neonates.

    Science.gov (United States)

    Kaempf, Joseph W; Tomlinson, Mark W; Kaempf, Andrew J; Wu, YingXing; Wang, Lian; Tipping, Nicole; Grunkemeier, Gary

    2012-08-01

    Delayed umbilical cord clamping is reported to increase neonatal blood volume. We estimated the clinical outcomes in premature neonates who had delayed umbilical cord clamping compared with a similar group who had early umbilical cord clamping. This was a before-after investigation comparing early umbilical cord clamping with delayed umbilical cord clamping (45 seconds) in two groups of singleton neonates, very low birth weight (VLBW) (401-1,500 g) and low birth weight (LBW) (greater than 1,500 g but less than 35 weeks gestation). Neonates were excluded from delayed umbilical cord clamping if they needed immediate major resuscitation. Primary outcomes were provision of delivery room resuscitation, hematocrit, red cell transfusions, and the principle Vermont Oxford Network outcomes. In VLBW neonates (77 delayed umbilical cord clamping, birth weight [mean±standard deviation] 1,099±266 g; 77 early umbilical cord clamping 1,058±289 g), delayed umbilical cord clamping was associated with less delivery room resuscitation, higher Apgar scores at 1 minute, and higher hematocrit. Delayed umbilical cord clamping was not associated with significant differences in the overall transfusion rate, peak bilirubin, any of the principle Vermont Oxford Network outcomes, or mortality. In LBW neonates (172 delayed umbilical cord clamping, birth weight [mean±standard deviation] 2,159±384 g; 172 early umbilical cord clamping 2,203±447 g), delayed umbilical cord clamping was associated with higher hematocrit and was not associated with a change in delivery room resuscitation or Apgar scores or with changes in the transfusion rate or peak bilirubin. Regression analysis showed increasing gestational age and birth weight and delayed umbilical cord clamping were the best predictors of higher hematocrit and less delivery room resuscitation. Delayed umbilical cord clamping can safely be performed in singleton premature neonates and is associated with a higher hematocrit, less delivery room

  3. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  4. Photovoltaic panel clamp

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Malcolm P.; Mittan, Margaret Birmingham; Miros, Robert H. J.; Stancel, Robert

    2013-03-19

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  5. Photovoltaic panel clamp

    Science.gov (United States)

    Mittan, Margaret Birmingham; Miros, Robert H. J.; Brown, Malcolm P.; Stancel, Robert

    2012-06-05

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  6. A Neutral-point Voltage Balancing Control Method for Three-level Neutral-point-clamped Inverter%一种三电平中性点钳位逆变器中点电位控制算法

    Institute of Scientific and Technical Information of China (English)

    江才; 宋文胜; 王顺亮; 韩坤; 冯晓云

    2014-01-01

    针对电力牵引三电平中性点钳位(NPC)逆变器系统,首先分析了因调制算法引起的中点电位振荡现象。然后分别比较两种传统空间矢量脉宽调制(SVPWM)算法对中点电位振荡及负载电流总谐波畸变率(THD)的影响;在此基础上,以中点电位平衡控制和最小负载电流THD含量为目的,提出了一种基于中点电位环宽控制的 SVPWM算法。最后,通过 MALTAB/Simulink 软件仿真和dSPACE半实物平台实验研究,对3种调制算法下中点电位及负载电流 THD值进行对比分析。计算机仿真与半实物实验结果表明,中点电位环宽控制方法不但能平衡直流侧中点电位,而且能有效地减小负载电流THD含量。%The neutral-point voltage oscillation due to the modulation method is analyzed first for the three-level neutral-point-clamped (NPC) traction inverter.Then,the characteristics of the neutral-point voltage oscillation and the total harmonic distortion(THD)of load current due to two traditional space vector pulse width modulation(SVPWM)methods are compared with each other,respectively.On the basis of this,a SVPWM method with adj ustment of neutral-point hysteresis-loop width is proposed to balance the neutral-point and reduce the THD value of load current.Finally,both the amplitude of neutral-point oscillation and the THD value of load current are compared and analyzed via MATLAB/Simulink simulation and dSPACE hardware-in-the-loop experiment when the three modulation methods are adopted.Simulation and experimental results show that the adopted SVPWM method with neutral-point loop width control is efficient for balancing neutral-point voltage and reducing the THD value of load current.

  7. Off-clamp robot-assisted partial nephrectomy does not benefit short-term renal function: a matched cohort analysis.

    Science.gov (United States)

    Anderson, Barrett G; Potretzke, Aaron M; Du, Kefu; Vetter, Joel; Figenshau, R Sherburne

    2017-08-31

    In the interest of renal functional preservation, partial nephrectomy has supplanted radical nephrectomy as the preferred treatment for T1 renal masses. This procedure usually involves the induction of renal warm ischemia by clamping the hilar vessels prior to tumor excision. Performing robot-assisted partial nephrectomy (RAPN) "off-clamp" can theoretically prevent renal functional loss associated with warm ischemia. We describe our institutional experience and compare perioperative and renal functional outcomes using a propensity score matched cohort. We conducted a retrospective comparison from a prospectively maintained database of all patients who underwent RAPN from 2009 to 2015. Of those patients, 143 underwent off-clamp RAPN. Fifty off-clamp RAPN patients were propensity score matched with fifty clamped RAPN patients based on renal function, tumor size, and R.E.N.A.L. nephrometry score. The cohorts were compared across demographics, operative information, perioperative outcomes, and renal functional outcomes. For all off-clamp RAPN patients, mean nephrometry score was 7.1, mean estimated blood loss (EBL) was 236.9 mL, perioperative complication rate was 7.7%, and mean decrease in estimated glomerular filtration rate (eGFR) was 7.1% at a median follow-up of 9.2 months. In the propensity score matched cohorts, off-clamp RAPN resulted in a shorter mean operative time (172.0 versus 196.0 min, p = 0.025) and a lower mean EBL (179.7 versus 283.2 mL, p = 0.046). A lower complication rate of 6.0% in the off-clamp group compared with 20.0% in the clamped group approached significance (p = 0.071). Mean preoperative eGFR was similar in both cohorts. Importantly, there was no significant difference in decrease in eGFR between the clamped cohort (9.8%) and off-clamp cohort (11.9%) at a median follow-up of 9.0 months (p = 0.620). Off-clamp RAPN did not result in improved renal functional preservation in our experience. Surprisingly, the off-clamp cohort

  8. Late vs early clamping of the umbilical cord in full-term neonates: systematic review and meta-analysis of controlled trials.

    Science.gov (United States)

    Hutton, Eileen K; Hassan, Eman S

    2007-03-21

    With few exceptions, the umbilical cord of every newborn is clamped and cut at birth, yet the optimal timing for this intervention remains controversial. To compare the potential benefits and harms of late vs early cord clamping in term infants. Search of 6 electronic databases (on November 15, 2006, starting from the beginning of each): the Cochrane Pregnancy and Childbirth Group trials register, the Cochrane Neonatal Group trials register, the Cochrane library, MEDLINE, EMBASE, and CINHAL; hand search of secondary references in relevant studies; and contact of investigators about relevant published research. Controlled trials comparing late vs early cord clamping following birth in infants born at 37 or more weeks' gestation. Two reviewers independently assessed eligibility and quality of trials and extracted data for outcomes of interest: infant hematologic status; iron status; and risk of adverse events such as jaundice, polycythemia, and respiratory distress. The meta-analysis included 15 controlled trials (1912 newborns). Late cord clamping was delayed for at least 2 minutes (n = 1001 newborns), while early clamping in most trials (n = 911 newborns) was performed immediately after birth. Benefits over ages 2 to 6 months associated with late cord clamping include improved hematologic status measured as hematocrit (weighted mean difference [WMD], 3.70%; 95% confidence interval [CI], 2.00%-5.40%); iron status as measured by ferritin concentration (WMD, 17.89; 95% CI, 16.58-19.21) and stored iron (WMD, 19.90; 95% CI, 7.67-32.13); and a clinically important reduction in the risk of anemia (relative risk (RR), 0.53; 95% CI, 0.40-0.70). Neonates with late clamping were at increased risk of experiencing asymptomatic polycythemia (7 studies [403 neonates]: RR, 3.82; 95% CI, 1.11-13.21; 2 high-quality studies only [281 infants]: RR, 3.91; 95% CI, 1.00-15.36). Delaying clamping of the umbilical cord in full-term neonates for a minimum of 2 minutes following birth is

  9. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  10. The non-selective voltage-activated cation channel in the human red blood cell membrane: reconciliation between two conflicting reports and further characterisation

    DEFF Research Database (Denmark)

    Kaestner, Lars; Christophersen, Palle; Bernhardt, Ingolf;

    2000-01-01

    Erythrocyte; Patch-clamp; Non-specific; cation channel; Voltage dependence; Acetylcholin receptor......Erythrocyte; Patch-clamp; Non-specific; cation channel; Voltage dependence; Acetylcholin receptor...

  11. Tools for voltage stability analysis, including a probabilistic approach

    Energy Technology Data Exchange (ETDEWEB)

    Vieira Filho, X.; Martins, N.; Bianco, A.; Pinto, H.J.C.P. [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil); Pereira, M.V.F. [Power System Research (PSR), Inc., Rio de Janeiro, RJ (Brazil); Gomes, P.; Santos, M.G. dos [ELETROBRAS, Rio de Janeiro, RJ (Brazil)

    1994-12-31

    This paper reviews some voltage stability analysis tools that are being used or envisioned for expansion and operational planning studies in the Brazilian system, as well as, their applications. The paper also shows that deterministic tools can be linked together in a probabilistic framework, so as to provide complementary help to the analyst in choosing the most adequate operation strategies, or the best planning solutions for a given system. (author) 43 refs., 8 figs., 8 tabs.

  12. Mitigation of Voltage Dip and Voltage Flickering by Multilevel D-STATCOM

    Directory of Open Access Journals (Sweden)

    M. S. Ballal

    2012-01-01

    Full Text Available The basic power quality problems in the distribution network are voltage sag (dip, voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.

  13. Analysis for Clamping Force of Hydraulic Slide-valve Spool Based on Fluent%基于Fluent的液压滑阀阀芯卡紧力研究

    Institute of Scientific and Technical Information of China (English)

    陈奎生; 周雯娟; 郭媛; 付曙光; 张宏伟; 蒋俊

    2011-01-01

    Through simulation and analysis, the changes in clamping force of the hydraulic slide-valve spool when the spool skewed were studied, with no pressure-equalizing grooves, three rectangular grooves, five rectangular grooves and five triangular grooves. The simulation results show; opening pressure-equalizing grooves in the valve can reduce clamping force; the more pressure equalizing grooves open, the smaller the clamping force becomes. With the same amount, clamping force of spool with rectangular grooves is larger than that with triangle grooves, but the spool with rectangular grooves is more conducive to become concentric.%通过仿真分析,研究液压滑阀阀芯在不开均压槽、开3条矩形槽、开5条矩形槽、开5条三角形槽4种情况下,阀芯歪斜时阀芯卡紧力的变化.由仿真结果可知:阀芯歪斜时,在阀芯上开均压槽可以有效减小卡紧力,开的均压槽越多,卡紧力越小;开相同数量的矩形槽比三角槽的卡紧力大,但是更利于使阀芯趋于同心.

  14. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F.; Yee, Daniel D.

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  15. Analysis of Voltage Support by Electric Vehicles and Photovoltaic in a Real Danish Low Voltage Network

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Juul Møller, René

    2014-01-01

    of incorporating electric vehicles (EVs) in a low voltage distribution network with high penetration of photovoltaic installations (PVs), and focuses on analysing potential voltage support functions from EVs and PVs. In addition, the paper evaluates the benefits that reactive power control may provide...

  16. Thermally-induced voltage alteration for integrated circuit analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Jr., Edward I. (Albuquerque, NM)

    2000-01-01

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

  17. Thermally-induced voltage alteration for integrated circuit analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cole, E.I. Jr.

    2000-06-20

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

  18. A Component-Reduced Zero-Voltage Switching Three-Level DC-DC Converter

    DEFF Research Database (Denmark)

    Qin, Zian; Pang, Ying; Wang, Huai;

    2016-01-01

    The basic Zero-Voltage Switching (ZVS) three-level DC-DC converter has one clamping capacitor to realize the ZVS of the switches, and two clamping diodes to clamp the voltage of the clamping capacitor. In order to reduce the reverse recovery loss of the diode as well as its cost, this paper...... proposes to remove one of the clamping diodes in basic ZVS three-level DC-DC converter. With less components, the proposed converter can still have a stable clamping capacitor voltage, which is clamped at half of the dc link voltage. Moreover, the ZVS performance will be influenced by removing the clamping...

  19. Thermal and efficiency analysis of five-level multi-level clamped multilevel converter considering grid codes

    DEFF Research Database (Denmark)

    Ma, Ke; Muñoz-Aguilar, S.; Rodriguez, P.;

    2012-01-01

    In this paper a five-level Multi-Clamped Multilevel Converter (5L-MLC2) topology is analyzed based on a typical grid integration application for renewable energy generation system. The loss and thermal distribution of the power devices in different switching legs are investigated and illustrated ...

  20. Analysis and Mathematical Model for Restitution of Voltage Using Dynamic Voltage Restorer

    Directory of Open Access Journals (Sweden)

    C. Gopinath

    2014-01-01

    Full Text Available Voltage sag and swell have a major concern in the distribution systems. In order to mitigate the voltage sag and swell, a custom power device called dynamic voltage restorer (DVR is used. The proposed system is a polymer electrolyte membrane (PEM fuel cell based DVR. The energy from the fuel cell is stored in the super capacitor to restitute the voltage. In this proposed DVR, Z-source inverter is used instead of traditional inverter because of buck-boost and shoot through capability. The simulation is performed using three controller topologies: PI controller, synchronous reference frame controller and fuzzy controller and the results are verified using Matlab-Simulink environment.

  1. Resonance analysis in parallel voltage-controlled Distributed Generation inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2013-01-01

    Thanks to the fast responses of the inner voltage and current control loops, the dynamic behaviors of parallel voltage-controlled Distributed Generation (DG) inverters not only relies on the stability of load sharing among them, but subjects to the interactions between the voltage control loops o...

  2. A dnaN plasmid shuffle strain for rapid in vivo analysis of mutant Escherichia coli β clamps provides insight into the role of clamp in umuDC-mediated cold sensitivity.

    Directory of Open Access Journals (Sweden)

    Vignesh M P Babu

    Full Text Available The E. coli umuDC gene products participate in two temporally distinct roles: UmuD2C acts in a DNA damage checkpoint control, while UmuD'2C, also known as DNA polymerase V (Pol V, catalyzes replication past DNA lesions via a process termed translesion DNA synthesis. These different roles of the umuDC gene products are managed in part by the dnaN-encoded β sliding clamp protein. Co-overexpression of the β clamp and Pol V severely blocked E. coli growth at 30°C. We previously used a genetic assay that was independent of the ability of β clamp to support E. coli viability to isolate 8 mutant clamp proteins (βQ61K, βS107L, βD150N, βG157S, βV170M, βE202K, βM204K and βP363S that failed to block growth at 30°C when co-overexpressed with Pol V. It was unknown whether these mutant clamps were capable of supporting E. coli viability and normal umuDC functions in vivo. The goals of this study were to answer these questions. To this end, we developed a novel dnaN plasmid shuffle assay. Using this assay, βD150N and βP363S were unable to support E. coli viability. The remaining 6 mutant clamps, each of which supported viability, were indistinguishable from β+ with respect to umuDC functions in vivo. In light of these findings, we analyzed phenotypes of strains overexpressing either β clamp or Pol V alone. The strain overexpressing β+, but not those expressing mutant β clamps, displayed slowed growth irrespective of the incubation temperature. Moreover, growth of the Pol V-expressing strain was modestly slowed at 30°, but not 42°C. Taken together, these results suggest the mutant clamps were identified due to their inability to slow growth rather than an inability to interact with Pol V. They further suggest that cold sensitivity is due, at least in part, to the combination of their individual effects on growth at 30°C.

  3. A dnaN plasmid shuffle strain for rapid in vivo analysis of mutant Escherichia coli β clamps provides insight into the role of clamp in umuDC-mediated cold sensitivity.

    Science.gov (United States)

    Babu, Vignesh M P; Sutton, Mark D

    2014-01-01

    The E. coli umuDC gene products participate in two temporally distinct roles: UmuD2C acts in a DNA damage checkpoint control, while UmuD'2C, also known as DNA polymerase V (Pol V), catalyzes replication past DNA lesions via a process termed translesion DNA synthesis. These different roles of the umuDC gene products are managed in part by the dnaN-encoded β sliding clamp protein. Co-overexpression of the β clamp and Pol V severely blocked E. coli growth at 30°C. We previously used a genetic assay that was independent of the ability of β clamp to support E. coli viability to isolate 8 mutant clamp proteins (βQ61K, βS107L, βD150N, βG157S, βV170M, βE202K, βM204K and βP363S) that failed to block growth at 30°C when co-overexpressed with Pol V. It was unknown whether these mutant clamps were capable of supporting E. coli viability and normal umuDC functions in vivo. The goals of this study were to answer these questions. To this end, we developed a novel dnaN plasmid shuffle assay. Using this assay, βD150N and βP363S were unable to support E. coli viability. The remaining 6 mutant clamps, each of which supported viability, were indistinguishable from β+ with respect to umuDC functions in vivo. In light of these findings, we analyzed phenotypes of strains overexpressing either β clamp or Pol V alone. The strain overexpressing β+, but not those expressing mutant β clamps, displayed slowed growth irrespective of the incubation temperature. Moreover, growth of the Pol V-expressing strain was modestly slowed at 30°, but not 42°C. Taken together, these results suggest the mutant clamps were identified due to their inability to slow growth rather than an inability to interact with Pol V. They further suggest that cold sensitivity is due, at least in part, to the combination of their individual effects on growth at 30°C.

  4. Voltage stability analysis of grid-connected wind farms with FACTS: Static and dynamic analysis

    Directory of Open Access Journals (Sweden)

    Kevin Zibran Heetun

    2016-01-01

    Full Text Available Recently, analysis of some major blackouts and failures of power system shows that voltage instability problem has been one of the main reasons of these disturbances and network collapses. In this article, a systematic approach to voltage stability analysis using various techniques for the IEEE 14-bus case study is presented. Static analysis is used to analyze the voltage stability of the system under study, while the dynamic analysis is used to evaluate the performance of compensators. The static techniques used are power flow, V–P curve analysis, and Q–V modal analysis. In this study, Flexible Alternating Current Transmission system (FACTS devices—namely, static synchronous compensators (STATCOMs and static var compensators (SVCs—are used as reactive power compensators, taking into account maintaining the violated voltage magnitudes of the weak buses within the acceptable limits defined in ANSI C84.1. Simulation results validate that both the STATCOMs and the SVCs can be effectively used to enhance the static voltage stability and increasing network loadability margin. Additionally, based on the dynamic analysis results, it has been shown that STATCOMs have superior performance, in dynamic voltage stability enhancement, compared to SVCs.

  5. 恒压钳位高速关断瞬变电磁发射系统%Voltage stabilized clamping and fast turn-off transient electromagnetic transmitting system

    Institute of Scientific and Technical Information of China (English)

    赵海涛; 刘丽华; 吴凯; 张建国; 方广有

    2013-01-01

    Transient electromagnetic transmitter is an important part in transient electromagnetic detection equipment. In the aspects of high-power current steep pulse transmission, high precision synchronous control, falling-edge linearity , short turn-off time, turn-off time measurement and etc. , there are still a lot of problems to be solved urgently. This paper proposes a novel extra fast turn-off transient electromagnetic transmitting system, DSP and FPGA are used to work together and provide the system with reliable driving signals and protective measures. The system adopts a voltage stabilized clamping circuit and a damping resistance circuit, and has the characteristics of short turn-off time, high current falling-edge linearity and high transmission current; besides it can improve the speed of pulse current rising-edge. The system also adopts a novel turn-off time measurement circuit, which makes the measurement simple and accurate. A GPS synchronous controller is designed, which adopts a cooperative operation mode with a temperature compensated crystal, solves the GPS short-time failure problem and improves the reliability of the system. The transmitting system field experiment was carried out,experiment results show that the system features high transmission current, good current falling-edge linearity, accurate turn-off time measurement, and precise and reliable synchronous control. The system is easy to carry,convenient to operate,and has excellent performance.%瞬变电磁发射机是瞬变电磁探测设备中的重要组成部分,在大功率电流陡脉冲发射、高精度同步控制、下降沿线性度、短关断时间和关断时间测量等方面,有许多亟待解决的问题.提出了一种瞬变电磁发射系统,DSP和FPGA协同工作为系统提供可靠的驱动信号和保护措施;提出了恒压钳位电路,配合合适的阻尼吸收电路,具有关断时间短、电流下降沿线性度高和发射电流大的特点,并可提升脉冲

  6. Piezoresistive cantilever force-clamp system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung-Jin; Petzold, Bryan C.; Pruitt, Beth L. [Department of Mechanical Engineering, Stanford University, Stanford, California 94305 (United States); Goodman, Miriam B. [Department of Molecular and Cellular Physiology, Stanford University, Stanford, California 94305 (United States)

    2011-04-15

    We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

  7. A new modeling of loading margin and its sensitivities using rectangular voltage coordinates in voltage stability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Vander Menengoy da; Rosa, Arlei Lucas de Sousa [Department of Electrical Engineering, Federal University of Juiz de Fora, Campus Universitario - Bairro Martelos, 36036-330 Juiz de Fora - MG (Brazil); Guedes, Magda Rocha [Federal Center of Technologic Education of Minas Gerais - CEFET, Rua Jose Peres, 558 36700-000 Leopoldina - MG (Brazil); Cantarino, Marcelo [Centrais Eletricas Brasileiras S.A - ELETROBRAS, Av. Rio Branco, 53, Centro, 14 andar, 20090-004 Rio de Janeiro - RJ (Brazil)

    2010-05-15

    This paper presents new mathematical models to compute the loading margin, as well as to perform the sensitivity analysis of loading margin with respect to different electric system parameters. The innovative idea consists of evaluating the performance of these methods when the power flow equations are expressed with the voltages in rectangular coordinates. The objective is to establish a comparative process with the conventional models expressed in terms of power flow equations with the voltages in polar coordinates. IEEE test system and a South-Southeastern Brazilian network are used in the simulations. (author)

  8. Analysis of Possibilities to Reduce the Voltages Induced in Multi-circuit and Multi-voltage Overhead Lines

    Directory of Open Access Journals (Sweden)

    Rafał Tarko

    2015-09-01

    Full Text Available This paper presents the issues of electromagnetic interactions in a four-circuit and dual-voltage power line. Such solutions are increasingly used in practice due to difficulties in land acquisition for the construction of new power lines. Lines of this type, however, have some disadvantages, incl. the electromagnetic interactions between the circuits and voltages induced as their consequence. These issues are considered in relation to an existing four-circuit, 110 kV and 15 kV line. Results of the studies of the interaction effects in a real system, and an analysis of selected ways to reduce the voltage induced in 15 kV line circuits are presented.

  9. A meta-analysis comparing the outcomes of LigaSure Small Jaw versus clamp-and-tie technique or Harmonic Focus Scalpel in thyroidectomy

    Science.gov (United States)

    Zhang, Lei; Li, Namei; Yang, Xuemei; Chen, Jie

    2017-01-01

    Abstract Background: LigaSure (LS) Small Jaw is a surgical hemostasis equipment that is newly introduced in thyroid surgery. The objective of this study is to assess the short-term efficacy and safety outcomes of LS Small Jaw compared with clamp-and-tie technique or Harmonic Focus Scalpel in thyroidectomy. Methods: A literature search was performed in the PubMed and Embase databases (until June 12, 2016) that reported the comparisons between LS Small Jaw and other techniques in thyroidectomy. Quality assessments were performed according to The Cochrane Collaboration's risk of bias tool and a modification of the Newcastle-Ottawa Scale in randomized controlled trials (RCTs) and non-RCTs, respectively. All statistical analyses were conducted using RevMan 5.3. Results: Finally, 7 studies with 813 patients were included into the meta-analysis, and all included studies were comparable with moderate-to-high quality. There was significant reduced operative time in LS Small Jaw, compared with clamp-and-tie (mean difference [MD] = −17.49, 95% confidence interval [CI]: −22.20 to 12.77, P < 0.00001) or Harmonic Focus Scalpel (MD = −2.29, 95% CI: −3.19 to 1.39, P < 0.00001). Besides, other perioperative outcomes including intraoperative blood loss and postoperative blood loss favored LS Small Jaw compared with clamp-and-tie. In terms of complications, less-temporary hypocalcemia rate was observed in LS Small Jaw compared with clamp-and-tie (odds ratio [OR] = 0.49, 95% CI: 0.27–0.90, P = 0.02), although no significant difference was detected compared with Harmonic Focus Scalpel (OR = 0.47, 95% CI: 0.14–1.56, P = 0.22). Other complications such as length of hospital stay, permanent hypocalcemia, temporary or permanent recurrent laryngeal nerve palsy, and hematomas were not significant. Conclusion: In conclusion, LS Small Jaw is more favorable than clamp-and-tie technique or Harmonic Focus Scalpel in thyroidectomy. PMID:28296728

  10. Review of Adult Electrical Burn Injury Outcomes Worldwide: An Analysis of Low-Voltage vs High-Voltage Electrical Injury.

    Science.gov (United States)

    Shih, Jessica G; Shahrokhi, Shahriar; Jeschke, Marc G

    The aims of this article are to review low-voltage vs high-voltage electrical burn complications in adults and to identify novel areas that are not recognized to improve outcomes. An extensive literature search on electrical burn injuries was performed using OVID MEDLINE, PubMed, and EMBASE databases from 1946 to 2015. Studies relating to outcomes of electrical injury in the adult population (≥18 years of age) were included in the study. Forty-one single-institution publications with a total of 5485 electrical injury patients were identified and included in the present study. Fourty-four percent of these patients were low-voltage injuries (LVIs), 38.3% high-voltage injuries (HVIs), and 43.7% with voltage not otherwise specified. Forty-four percentage of studies did not characterize outcomes according to LHIs vs HVIs. Reported outcomes include surgical, medical, posttraumatic, and others (long-term/psychological/rehabilitative), all of which report greater incidence rates in HVI than in LVI. Only two studies report on psychological outcomes such as posttraumatic stress disorder. Mortality rates from electrical injuries are 2.6% in LVI, 5.2% in HVI, and 3.7% in not otherwise specified. Coroner's reports revealed a ratio of 2.4:1 for deaths caused by LVI compared with HVI. HVIs lead to greater morbidity and mortality than LVIs. However, the results of the coroner's reports suggest that immediate mortality from LVI may be underestimated. Furthermore, on the basis of this analysis, we conclude that the majority of studies report electrical injury outcomes; however, the majority of them do not analyze complications by low vs high voltage and often lack long-term psychological and rehabilitation outcomes after electrical injury indicating that a variety of central aspects are not being evaluated or assessed.

  11. Vibration-based energy harvesting with a clamped piezoelectric circular diaphragm: analysis and identification of optimal structural parameters

    Science.gov (United States)

    Yang, Yangyiwei; Wang, Shuai; Stein, Peter; Xu, Bai-Xiang; Yang, Tongqing

    2017-04-01

    Due to many potential promising applications, vibration-based piezoelectric energy harvesters (VPEH) with a clamped circular diaphragm are an intensively studied design in the field of piezoelectric energy harvesters. Nonetheless, their performance still leaves space for improvement, which is the primary target of this article. We define two structural parameters, namely the ratio ϖ 1 between the bonding area and the piezoceramic diameter as well as the ratio ϖ 2 between the clamping rim and the substrate diameter, to characterize these structures. A vibration model is developed in order to provide an analytical foundation for the identification of optimal parameters ϖ 1 and ϖ 2. It is verified by finite-element simulations and substantive experiments. The results allow to relate the device performance, including resonance frequency and output power, to ϖ 1 and ϖ 2. This shows that the output rises with increasing ϖ 2, and that the maximum output for a given ϖ 2 always lies in the range {\\varpi }1\\in ({0.1,} 0.2). Based on this observation, an improved harvester structure with a pre-stress of 0.3 N is identified, that exhibits a matched power up to 16.3 mW at 219 Hz. This demonstrates the feasibility to achieve VPEHs with higher outputs and lower eigenfrequency through simultaneous modification of ϖ 1 and ϖ 2, which is highly beneficial for low-frequency energy harvesting.

  12. Advantages and limitations of transition voltage spectroscopy: A theoretical analysis

    NARCIS (Netherlands)

    Mirjani, F.; Thijssen, J.M.; Van der Molen, S.J.

    2011-01-01

    In molecular charge transport, transition voltage spectroscopy (TVS) holds the promise that molecular energy levels can be explored at bias voltages lower than required for resonant tunneling. We investigate the theoretical basis of this tool using a generic model. In particular, we study the length

  13. Transient Voltage Stability Analysis and Improvement of A Network with different HVDC Systems

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2011-01-01

    the theoretical analysis and the improved control method, real time simulation model of a hybrid multi-infeed HVDC system based on western Danish power system is established in RTDS™. Simulation results show that the enhanced transient voltage stability can be achieved.......This paper presents transient voltage stability analysis of an AC system with multi-infeed HVDC links including a traditional LCC HVDC link and a VSC HVDC link. It is found that the voltage supporting capability of the VSC-HVDC link is significantly influenced by the tie-line distance between...... the two links and the size of loads. In order to improve the transient voltage stability, a voltage adjusting method is proposed in this paper. A voltage increment component has been introduced into the outer voltage control loop under emergency situation caused by severe grid faults. In order to verify...

  14. Planar patch-clamp force microscopy on living cells

    Energy Technology Data Exchange (ETDEWEB)

    Pamir, Evren [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany); George, Michael; Fertig, Niels [Nanion Technologies GmbH, Erzgiessereistr. 4, 80335 Munich (Germany); Benoit, Martin [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany)], E-mail: martin.benoit@physik.uni-muenchen.de

    2008-05-15

    Here we report a new combination of the patch-clamp technique with the atomic force microscope (AFM). A planar patch-clamp chip microstructured from borosilicate glass was used as a support for mechanical probing of living cells. The setup not only allows for immobilizing even a non-adherent cell for measurements of its mechanical properties, but also for simultaneously measuring the electrophysiological properties of a single cell. As a proof of principle experiment we measured the voltage-induced membrane movement of HEK293 and Jurkat cells in the whole-cell voltage clamp configuration. The results of these measurements are in good agreement with previous studies. By using the planar patch-clamp chip for immobilization, the AFM not only can image non-adhering cells, but also gets easily access to an electrophysiologically controlled cellular probe at low vibrational noise.

  15. Reconstruction of Cell Surface Densities of Ion Pumps, Exchangers, and Channels from mRNA Expression, Conductance Kinetics, Whole-Cell Calcium, and Current-Clamp Voltage Recordings, with an Application to Human Uterine Smooth Muscle Cells.

    Directory of Open Access Journals (Sweden)

    Jolene Atia

    2016-04-01

    Full Text Available Uterine smooth muscle cells remain quiescent throughout most of gestation, only generating spontaneous action potentials immediately prior to, and during, labor. This study presents a method that combines transcriptomics with biophysical recordings to characterise the conductance repertoire of these cells, the 'conductance repertoire' being the total complement of ion channels and transporters expressed by an electrically active cell. Transcriptomic analysis provides a set of potential electrogenic entities, of which the conductance repertoire is a subset. Each entity within the conductance repertoire was modeled independently and its gating parameter values were fixed using the available biophysical data. The only remaining free parameters were the surface densities for each entity. We characterise the space of combinations of surface densities (density vectors consistent with experimentally observed membrane potential and calcium waveforms. This yields insights on the functional redundancy of the system as well as its behavioral versatility. Our approach couples high-throughput transcriptomic data with physiological behaviors in health and disease, and provides a formal method to link genotype to phenotype in excitable systems. We accurately predict current densities and chart functional redundancy. For example, we find that to evoke the observed voltage waveform, the BK channel is functionally redundant whereas hERG is essential. Furthermore, our analysis suggests that activation of calcium-activated chloride conductances by intracellular calcium release is the key factor underlying spontaneous depolarisations.

  16. Reconstruction of Cell Surface Densities of Ion Pumps, Exchangers, and Channels from mRNA Expression, Conductance Kinetics, Whole-Cell Calcium, and Current-Clamp Voltage Recordings, with an Application to Human Uterine Smooth Muscle Cells.

    Science.gov (United States)

    Atia, Jolene; McCloskey, Conor; Shmygol, Anatoly S; Rand, David A; van den Berg, Hugo A; Blanks, Andrew M

    2016-04-01

    Uterine smooth muscle cells remain quiescent throughout most of gestation, only generating spontaneous action potentials immediately prior to, and during, labor. This study presents a method that combines transcriptomics with biophysical recordings to characterise the conductance repertoire of these cells, the 'conductance repertoire' being the total complement of ion channels and transporters expressed by an electrically active cell. Transcriptomic analysis provides a set of potential electrogenic entities, of which the conductance repertoire is a subset. Each entity within the conductance repertoire was modeled independently and its gating parameter values were fixed using the available biophysical data. The only remaining free parameters were the surface densities for each entity. We characterise the space of combinations of surface densities (density vectors) consistent with experimentally observed membrane potential and calcium waveforms. This yields insights on the functional redundancy of the system as well as its behavioral versatility. Our approach couples high-throughput transcriptomic data with physiological behaviors in health and disease, and provides a formal method to link genotype to phenotype in excitable systems. We accurately predict current densities and chart functional redundancy. For example, we find that to evoke the observed voltage waveform, the BK channel is functionally redundant whereas hERG is essential. Furthermore, our analysis suggests that activation of calcium-activated chloride conductances by intracellular calcium release is the key factor underlying spontaneous depolarisations.

  17. Quantitative analysis of irreversibilities causes voltage drop in fuel cell (simulation and modeling)

    Energy Technology Data Exchange (ETDEWEB)

    Ghadamian, Hossein [Azad Univ., Dept. of Energy Engineering, Tehran (Iran); Saboohi, Yadolah [Sharif Energy Research Inst. (SERI), Tehran (Iran)

    2004-11-30

    Power level of a fuel cell depends on its operating condition, which is product of voltage and current-density the highest level of voltage is identified as reversible open circuit voltage (ROCV), which represents an ideal theoretical case [J. Larmin, A. Dicks, Fuel Cell System Explained, Wiley, 2000 (ISBN)]. Compared to that is ideal operating voltage which is usually characterized as open circuit voltage (OCV). An evaluation of deviation of operating voltage level from ideal operational case may provide information on the extent of improving efficiency and energy efficiency of a fuel cell. Therefore, quantification of operation deviation from OCV is the main point that is discussed in the present paper. The analysis procedure of voltage drop is based on step-by-step review of voltage drops over activation, internal currents (fuel-cross-over), Ohmic and mass-transport or concentration losses. Accumulated total voltage drops would be estimated as a sum of aforementioned losses. The accumulated voltage drops will then be reduced from OCV to obtain the operating voltage level. The above numerical analysis has been applied to identify the extents of voltage drop. The possible reducing variables in voltage drops reviewed and concluded that the activation loss has considerable impact on total voltage drops and it explains the most part of total losses. It is also found that the following correspondence parameters cause decrease in voltage drops: 1. Temperature increasing; 2. Pressure increasing; 3. Hydrogen or oxygen concentration increasing; 4. Electrode effective surface increasing; 5. Electrode and electrolyte, conductivity modification; 6. Electrolyte thickness reducing up to possible limitation; 7. Connection modification. (Author)

  18. Clamping Sequence, Fixture Layout and Clamping Force on Machining Deformation and Synchronous Optimization Analysis%夹紧顺序、夹具布局和夹紧力对装夹变形影响与同步优化分析研究

    Institute of Scientific and Technical Information of China (English)

    许晓宇; 赵晓慈

    2016-01-01

    为减小工件装夹变形,提高薄壁件加工精度,以薄壁零件装夹变形最小化为目标函数,通过遗传算法和有限元方法相结合,提出夹紧顺序、装夹布局和夹紧力同步分析方法。用该方法对一航空薄壁零件装夹进行优化分析,优化结果与经验设计及传统分析结果进行对比,有效地降低了工件因装夹不当引起的变形,验证了夹紧顺序、夹具布局和夹紧力同步优化方法的有效性。%In order to minimize the clamping deformation and improve the machining accuracy of thin-walled parts, a synchronous optimization method of clamping sequences, fixture layout and clamping forces was presented with the objective function of minimizing the deformation and through the combination of genetic algorithm and finite element method. An aviation thin-walled work piece was optimized by this method, and compared the optimization results with the experience empirical design and the traditional analysis results. This method can effectively reduce the work piece deformation due to improper clamping and improve the machining accuracy. The result proved the veracity of the synchronous optimization method of clamping sequences, fixture layout and clamping forces.

  19. Steady-state analysis of the effect of reactive generation limits in voltage stability

    Energy Technology Data Exchange (ETDEWEB)

    Echavarren, F.M.; Lobato, E.; Rouco, L. [School of Engineering of Universidad Pontificia Comillas, C/Alberto Aguilera, 23, 28015 Madrid (Spain)

    2009-09-15

    Voltage collapse phenomena are highly affected by reactive power generation limits. Saturation of the reactive power generation limits of a unit may result in a deterioration of the voltage stability. However, in some cases when the power network is operating close to the voltage collapse point, the reactive power generation saturation of a unit can change the system voltages immediately from stable to unstable; thus, a dynamic voltage collapse leading to blackout may follow. This paper presents a steady-state analysis of the immediate instability caused by reactive power generation saturation phenomena. For this purpose, the paper proposes a novel index that evaluates ''when'' and ''why'' a reactive power generation saturation will only result in a deterioration of the system voltage stability or, on the contrary, it will make the system voltages immediately unstable. (author)

  20. Analysis and Improvement of Reflection-type Transverse Modulation Optical Voltage Sensors

    Institute of Scientific and Technical Information of China (English)

    LUO Sunan; YE Miaoyuan; XU Yan; CUI Ying

    2001-01-01

    Reflection-type transverse modulation optical voltage sensors, which employ reflection retarders to replace quarter-wave plates, are convenient for practical use. In previous literatures, the measured voltage was all applied to Bi4Ge3O12 crystal along the (110) direction for transverse modulation optical voltage sensor, and crystals are used as sensing materials. In this paper, reflection-type transverse modulation optical voltage sensor has been analyzed theoretically and a novel configuration in which the measured voltage is applied to a Bi4C-e3O12 crystal along the (001) direction with light wave passing through the crystal in the (110) direction has been proposed. According to this theoretical analysis, a novel optical voltage sensor, which can be used in a 220 kV optical fiber voltage transformer, has been designed and assembled. Experimental results showed that the linearity and the stability of the sensor during 24 hours can reach 0.3%.

  1. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (series connected step-up (1:10) transformers

    Science.gov (United States)

    Redondo, L. M.; Fernando Silva, J.; Margato, E.

    2007-03-01

    This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5kV modules, 800V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15kV/1A pulses with 5μs width, 10kHz repetition rate, with less than 1μs pulse rise time. Experimental results for resistive loads are presented and discussed.

  2. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (series connected step-up (1:10) transformers.

    Science.gov (United States)

    Redondo, L M; Fernando Silva, J; Margato, E

    2007-03-01

    This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5 kV modules, 800 V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15 kV1 A pulses with 5 micros width, 10 kHz repetition rate, with less than 1 micros pulse rise time. Experimental results for resistive loads are presented and discussed.

  3. Can robots patch-clamp as well as humans? Characterization of a novel sodium channel mutation.

    Science.gov (United States)

    Estacion, M; Choi, J S; Eastman, E M; Lin, Z; Li, Y; Tyrrell, L; Yang, Y; Dib-Hajj, S D; Waxman, S G

    2010-06-01

    Ion channel missense mutations cause disorders of excitability by changing channel biophysical properties. As an increasing number of new naturally occurring mutations have been identified, and the number of other mutations produced by molecular approaches such as in situ mutagenesis has increased, the need for functional analysis by patch-clamp has become rate limiting. Here we compare a patch-clamp robot using planar-chip technology with human patch-clamp in a functional assessment of a previously undescribed Nav1.7 sodium channel mutation, S211P, which causes erythromelalgia. This robotic patch-clamp device can increase throughput (the number of cells analysed per day) by 3- to 10-fold. Both modes of analysis show that the mutation hyperpolarizes activation voltage dependence (8 mV by manual profiling, 11 mV by robotic profiling), alters steady-state fast inactivation so that it requires an additional Boltzmann function for a second fraction of total current (approximately 20% manual, approximately 40% robotic), and enhances slow inactivation (hyperpolarizing shift--15 mV by human,--13 mV robotic). Manual patch-clamping demonstrated slower deactivation and enhanced (approximately 2-fold) ramp response for the mutant channel while robotic recording did not, possibly due to increased temperature and reduced signal-to-noise ratio on the robotic platform. If robotic profiling is used to screen ion channel mutations, we recommend that each measurement or protocol be validated by initial comparison to manual recording. With this caveat, we suggest that, if results are interpreted cautiously, robotic patch-clamp can be used with supervision and subsequent confirmation from human physiologists to facilitate the initial profiling of a variety of electrophysiological parameters of ion channel mutations.

  4. Modeling of SVM Diode Clamping Three-Level Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the diode clamping three-level inverter connected to grid and good results are obtained. First the output voltage SVM is described for diode clamping three-level inverter with loads connected to Y. Then the output voltage SVM of diode clamping three-level inverter is simply...... is very powerful tool to real power circuits and it is very easy to simulate them. They have also verified that SVM control strategy is feasible to control the diode clamping three-level inverter....

  5. Stability Analysis of DC-link Voltage Control on Autonomous Micro Hydro Power Plant System

    OpenAIRE

    Feri Yusivar; M. Shanizal; A. Subiantoro; Gunawan, R

    2014-01-01

    Micro Hydro Power Plant has become one of the interesting topics to be researched nowadays. This paper deals with the stability analysis on control system of excitation voltage in Micro Hydro Power Plant. The control of this voltage can be achieved by controlling the Permanent Magnet Synchronous Machine (PMSM) with particular algorithm so the voltage on the DC-link part of the system can be controlled. Without knowing the exact specification of system parameters, the system will be most likel...

  6. MEMS-based force-clamp analysis of the role of body stiffness in C. elegans touch sensation.

    Science.gov (United States)

    Petzold, Bryan C; Park, Sung-Jin; Mazzochette, Eileen A; Goodman, Miriam B; Pruitt, Beth L

    2013-06-01

    Touch is enabled by mechanoreceptor neurons in the skin and plays an essential role in our everyday lives, but is among the least understood of our five basic senses. Force applied to the skin deforms these neurons and activates ion channels within them. Despite the importance of the mechanics of the skin in determining mechanoreceptor neuron deformation and ultimately touch sensation, the role of mechanics in touch sensitivity is poorly understood. Here, we use the model organism Caenorhabditis elegans to directly test the hypothesis that body mechanics modulate touch sensitivity. We demonstrate a microelectromechanical system (MEMS)-based force clamp that can apply calibrated forces to freely crawling C. elegans worms and measure touch-evoked avoidance responses. This approach reveals that wild-type animals sense forces <1 μN and indentation depths <1 μm. We use both genetic manipulation of the skin and optogenetic modulation of body wall muscles to alter body mechanics. We find that small changes in body stiffness dramatically affect force sensitivity, while having only modest effects on indentation sensitivity. We investigate the theoretical body deformation predicted under applied force and conclude that local mechanical loads induce inward bending deformation of the skin to drive touch sensation in C. elegans.

  7. Effects of Tramadol on Substantia Gelatinosa Neurons in the Rat Spinal Cord: An In Vivo Patch-Clamp Analysis

    Science.gov (United States)

    Yamasaki, Hiroyuki; Funai, Yusuke; Funao, Tomoharu; Mori, Takashi; Nishikawa, Kiyonobu

    2015-01-01

    Tramadol is thought to modulate synaptic transmissions in the spinal dorsal horn mainly by activating µ-opioid receptors and by inhibiting the reuptake of monoamines in the CNS. However, the precise mode of modulation remains unclear. We used an in vivo patch clamp technique in urethane-anesthetized rats to determine the antinociceptive mechanism of tramadol. In vivo whole-cell recordings of spontaneous inhibitory postsynaptic currents (sIPSCs) and spontaneous excitatory postsynaptic currents (sEPSCs) were made from substantia gelatinosa (SG) neurons (lamina II) at holding potentials of 0 mV and -70 mV, respectively. The effects of intravenous administration (0.5, 5, 15 mg/kg) of tramadol were evaluated. The effects of superfusion of tramadol on the surface of the spinal cord and of a tramadol metabolite (M1) were further analyzed. Intravenous administration of tramadol at doses >5 mg/kg decreased the sEPSCs and increased the sIPSCs in SG neurons. These effects were not observed following naloxone pretreatment. Tramadol superfusion at a clinically relevant concentration (10 µM) had no effect, but when administered at a very high concentration (100 µM), tramadol decreased sEPSCs, produced outward currents, and enhanced sIPSCs. The effects of M1 (1, 5 mg/kg intravenously) on sEPSCs and sIPSCs were similar to those of tramadol at a corresponding dose (5, 15 mg/kg). The present study demonstrated that systemically administered tramadol indirectly inhibited glutamatergic transmission, and enhanced GABAergic and glycinergic transmissions in SG neurons. These effects were mediated primarily by the activation of μ-opioid receptors. M1 may play a key role in the antinociceptive mechanisms of tramadol. PMID:25933213

  8. Effects of tramadol on substantia gelatinosa neurons in the rat spinal cord: an in vivo patch-clamp analysis.

    Science.gov (United States)

    Yamasaki, Hiroyuki; Funai, Yusuke; Funao, Tomoharu; Mori, Takashi; Nishikawa, Kiyonobu

    2015-01-01

    Tramadol is thought to modulate synaptic transmissions in the spinal dorsal horn mainly by activating µ-opioid receptors and by inhibiting the reuptake of monoamines in the CNS. However, the precise mode of modulation remains unclear. We used an in vivo patch clamp technique in urethane-anesthetized rats to determine the antinociceptive mechanism of tramadol. In vivo whole-cell recordings of spontaneous inhibitory postsynaptic currents (sIPSCs) and spontaneous excitatory postsynaptic currents (sEPSCs) were made from substantia gelatinosa (SG) neurons (lamina II) at holding potentials of 0 mV and -70 mV, respectively. The effects of intravenous administration (0.5, 5, 15 mg/kg) of tramadol were evaluated. The effects of superfusion of tramadol on the surface of the spinal cord and of a tramadol metabolite (M1) were further analyzed. Intravenous administration of tramadol at doses >5 mg/kg decreased the sEPSCs and increased the sIPSCs in SG neurons. These effects were not observed following naloxone pretreatment. Tramadol superfusion at a clinically relevant concentration (10 µM) had no effect, but when administered at a very high concentration (100 µM), tramadol decreased sEPSCs, produced outward currents, and enhanced sIPSCs. The effects of M1 (1, 5 mg/kg intravenously) on sEPSCs and sIPSCs were similar to those of tramadol at a corresponding dose (5, 15 mg/kg). The present study demonstrated that systemically administered tramadol indirectly inhibited glutamatergic transmission, and enhanced GABAergic and glycinergic transmissions in SG neurons. These effects were mediated primarily by the activation of μ-opioid receptors. M1 may play a key role in the antinociceptive mechanisms of tramadol.

  9. Single electrode dynamic clamp with StdpC.

    Science.gov (United States)

    Samu, David; Marra, Vincenzo; Kemenes, Ildiko; Crossley, Michael; Kemenes, György; Staras, Kevin; Nowotny, Thomas

    2012-10-15

    Dynamic clamp is a powerful approach for electrophysiological investigations allowing researchers to introduce artificial electrical components into target neurons to simulate ionic conductances, chemical or electrotonic inputs or connections to other cells. Due to the rapidly changing and potentially large current injections during dynamic clamp, problematic voltage artifacts appear on the electrode used to inject dynamic clamp currents into a target neuron. Dynamic clamp experiments, therefore, typically use two separate electrodes in the same cell, one for recording membrane potential and one for injecting currents. The requirement for two independent electrodes has been a limiting factor for the use of dynamic clamp in applications where dual recordings of this kind are difficult or impossible to achieve. The recent development of an active electrode compensation (AEC) method has overcome some of these prior limitations, permitting artifact-free dynamic clamp experimentation with a single electrode. Here we describe an AEC method for the free dynamic clamp software StdpC. The AEC component of StdpC is the first such system implemented for the use of non-expert users and comes with a set of semi-automated configuration and calibration procedures that facilitate its use. We briefly introduce the AEC method and its implementation in StdpC and then validate it with an electronic model cell and in two different biological preparations.

  10. The Space-Clamped Hodgkin-Huxley System with Random Synaptic Input: Inhibition of Spiking by Weak Noise and Analysis with Moment Equations.

    Science.gov (United States)

    Tuckwell, Henry C; Ditlevsen, Susanne

    2016-10-01

    We consider a classical space-clamped Hodgkin-Huxley model neuron stimulated by synaptic excitation and inhibition with conductances represented by Ornstein-Uhlenbeck processes. Using numerical solutions of the stochastic model system obtained by an Euler method, it is found that with excitation only, there is a critical value of the steady-state excitatory conductance for repetitive spiking without noise, and for values of the conductance near the critical value, small noise has a powerfully inhibitory effect. For a given level of inhibition, there is also a critical value of the steady-state excitatory conductance for repetitive firing, and it is demonstrated that noise in either the excitatory or inhibitory processes or both can powerfully inhibit spiking. Furthermore, near the critical value, inverse stochastic resonance was observed when noise was present only in the inhibitory input process. The system of deterministic differential equations for the approximate first- and second-order moments of the model is derived. They are solved using Runge-Kutta methods, and the solutions are compared with the results obtained by simulation for various sets of parameters, including some with conductances obtained by experiment on pyramidal cells of rat prefrontal cortex. The mean and variance obtained from simulation are in good agreement when there is spiking induced by strong stimulation and relatively small noise or when the voltage is fluctuating at subthreshold levels. In the occasional spike mode sometimes exhibited by spinal motoneurons and cortical pyramidal cells, the assumptions underlying the moment equation approach are not satisfied. The simulation results show that noisy synaptic input of either an excitatory or inhibitory character or both may lead to the suppression of firing in neurons operating near a critical point and this has possible implications for cortical networks. Although suppression of firing is corroborated for the system of moment equations

  11. Analysis of Discontinuous Space Vector PWM Techniques for a Seven-Phase Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Mohd. Arif Khan

    2012-03-01

    Full Text Available This paper presents discontinuous space vector PWM (DPWM techniques for a seven-phase voltage source inverter (VSI. Space vector model of a seven-phase VSI shows that there exist 128 space vectors with different lengths and maps into fourteen sided polygons. A number of possibilities could arise to implement modulation of inverter legs due to large number of available space voltage vectors. Two strategies are adopted here; one utilising large and two middle sets of space vectors to implement discontinuous space vector PWM. Clamping of legs of inverter to either positive or negative dc bus leads to discontinuity in the switching and consequently offers reduced switching loss modulation strategy. A significant reduction in switching losses can be achieved while employing DPWM in a seven-phase VSI. A generalised method is also proposed to realize the DPWM in a seven-phase VSI. Comparison of continuous and discontinuous PWM is presented in terms of switching current ripple. The experimental set-up is illustrated and the experimental results are presented.

  12. The use of a portable breath analysis device in monitoring type 1 diabetes patients in a hypoglycaemic clamp: validation with SIFT-MS data.

    Science.gov (United States)

    Walton, C; Patel, M; Pitts, D; Knight, P; Hoashi, S; Evans, M; Turner, C

    2014-09-01

    Monitoring blood glucose concentrations is a necessary but tedious task for people suffering from diabetes. It has been noted that breath in people suffering with diabetes has a different odour and thus it may be possible to use breath analysis to monitor the blood glucose concentration. Here, we evaluate the analysis of breath using a portable device containing a single mixed metal oxide sensor during hypoglycaemic glucose clamps and compare that with the use of SIFT-MS described in previously published work on the same set of patients. Outputs from both devices have been correlated with the concentration of blood glucose in eight volunteers suffering from type 1 diabetes mellitus. The results demonstrate that acetone as measured by SIFT-MS and the sensor output from the breath sensing device both correlate linearly with blood glucose; however, the sensor response and acetone concentrations differ greatly between patients with the same blood glucose. It is therefore unlikely that breath analysis can entirely replace blood glucose testing.

  13. Stability Analysis of DC-link Voltage Control on Autonomous Micro Hydro Power Plant System

    Directory of Open Access Journals (Sweden)

    Feri Yusivar

    2014-12-01

    Full Text Available Micro Hydro Power Plant has become one of the interesting topics to be researched nowadays. This paper deals with the stability analysis on control system of excitation voltage in Micro Hydro Power Plant. The control of this voltage can be achieved by controlling the Permanent Magnet Synchronous Machine (PMSM with particular algorithm so the voltage on the DC-link part of the system can be controlled. Without knowing the exact specification of system parameters, the system will be most likely unstable. The DC-link control system is modeled, simulated, and mathematically analyzed so the parameter specification for the stable system can be obtained.

  14. High Performance ZVT with Bus Clamping Modulation Technique for Single Phase Full Bridge Inverters

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Yinglai; Ayyanar, Raja

    2016-03-20

    This paper proposes a topology based on bus clamping modulation and zero-voltage-transition (ZVT) technique to realize zero-voltage-switching (ZVS) for all the main switches of the full bridge inverters, and inherent ZVS and/or ZCS for the auxiliary switches. The advantages of the strategy include significant reduction in the turn-on loss of the ZVT auxiliary switches which typically account for a major part of the total loss in other ZVT circuits, and reduction in the voltage ratings of auxiliary switches. The modulation scheme and the commutation stages are analyzed in detail. Finally, a 1kW, 500 kHz switching frequency inverter of the proposed topology using SiC MOSFETs has been built to validate the theoretical analysis. The ZVT with bus clamping modulation technique of fixed timing and adaptive timing schemes are implemented in DSP TMS320F28335 resulting in full ZVS for the main switches in the full bridge inverter. The proposed scheme can save up to 33 % of the switching loss compared with no ZVT case.

  15. Imaging with low-voltage scanning transmission electron microscopy: A quantitative analysis

    Energy Technology Data Exchange (ETDEWEB)

    Felisari, L. [TASC, INFM-CNR, S.S. 14, km 163.5, 34149 Trieste (Italy); Grillo, V., E-mail: vincenzo.grillo@unimore.it [Istituto Nanoscienze-S3 CNR, via Campi 213/A, 41125 Modena (Italy); IMEM-CNR Parco Area delle Scienze 37/A, 43124 Parma (Italy); Jabeen, F.; Rubini, S. [TASC, INFM-CNR, S.S. 14, km 163.5, 34149 Trieste (Italy); Menozzi, C. [Istituto Nanoscienze-S3 CNR, via Campi 213/A, 41125 Modena (Italy); Dipartimento di Fisica, Universita di Modena e Reggio Emilia Via G. Campi 213/A, 41100 Modena (Italy); Rossi, F. [IMEM-CNR Parco Area delle Scienze 37/A, 43124 Parma (Italy); Martelli, F. [TASC, INFM-CNR, S.S. 14, km 163.5, 34149 Trieste (Italy); IMM-CNR, via del Fosso del Cavaliere 100, 00133 Roma (Italy)

    2011-07-15

    A dedicated specimen holder has been designed to perform low-voltage scanning transmission electron microscopy in dark field mode. Different test samples, namely InGaAs/GaAs quantum wells, InGaAs nanowires and thick InGaAs layers, have been analysed to test the reliability of the model based on the proportionality to the specimen mass-thickness, generally used for image intensity interpretation of scattering contrast processes. We found that size of the probe, absorption and channelling must be taken into account to give a quantitative interpretation of image intensity. We develop a simple procedure to evaluate the probe-size effect and to obtain a quantitative indication of the absorption coefficient. Possible artefacts induced by channelling are pointed out. With the developed procedure, the low voltage approach can be successfully applied for quantitative compositional analysis. The method is then applied to the estimation of the In content in the core of InGaAs/GaAs core-shell nanowires. -- Highlights: {yields} Quantitative analysis of the composition by low-voltage STEM annular dark field. {yields} First evidence of channelling effects in low-voltage STEM in SEM. {yields} Comparison between low-voltage and high-voltage STEM. {yields} Evaluation of the absorption effects on the STEM intensity.

  16. Management of umbilical cord clamping.

    Science.gov (United States)

    Webbon, Lucy

    2013-02-01

    The Royal College of Midwives (RCM) has updated its third stage of labour guidelines (RCM 2012) to be clearly supportive of a delay in umbilical cord clamping, although specific guidance on timing is yet to be announced. It is therefore imperative that both midwives and student midwives understand and are able to integrate delaying into their practice, as well as communicating to women the benefits; only in this way can we give women fully informed choices on this aspect of care. The main benefit of delayed cord clamping is the protection it can provide in reducing childhood anaemia, which is a major issue, especially in poorer countries. A review of the evidence found no risks linked to delayed clamping, and no evidence that it cannot be used in combination with the administration of uterotonic drugs. Delayed cord clamping can be especially beneficial for pre term and compromised babies.

  17. Harmonic Analysis of Currents and Voltages Obtained in the Result of Computational Experiment

    Directory of Open Access Journals (Sweden)

    I. V. Novash

    2011-01-01

    Full Text Available The paper considers a methodology for execution of a harmonic analysis of current and voltage numerical values obtained in the result of a computational experiment and saved in an external data file. The harmonic analysis has been carried out in the Mathcad mathematical packet environment.

  18. Analysis of Torque Ripple Reduction in Induction Motor DTC Drive with Multiple Voltage Vectors

    Directory of Open Access Journals (Sweden)

    ROSIC, M. M.

    2015-02-01

    Full Text Available This paper shows an analysis of torque ripple reduction in modified DTC algorithm by using multiple voltage vectors with the appropriate multilevel hysteresis controller. A short theoretical background of classical and proposed DTC algorithm was given at the beginning. Experimental results of the proposed DTC algorithm, implemented on digital signal processor F2812, were analysed in comparison with classical DTC. It is shown that the torque ripple can be reduced by selecting voltage vectors with an appropriate intensity. Motor current oversampling was used to analyse the estimated torque behaviour during one DSP sampling period. Furthermore, the analysis of torque ripple reduction with oversampled torque values was conducted in relation to the number of available voltage vectors. The analysis shows that the proposed DTC algorithm allows significant torque ripple reduction while retaining the simplicity, small computational burden and good dynamic characteristics of the classical DTC.

  19. Analysis of first proximity voltage on the property of GEN Ⅲ image intensifier

    Science.gov (United States)

    Zhang, Ni; Zhu, Yu-feng; Li, Dan; Nie, Jing; Zhang, Tai-min; Liu, Xiao-jian; Liu, Zhao-lu; Cheng, Wei; Fu, Ling-yun

    2013-08-01

    First proximity voltage is the voltage between the cathode of Low Light Level image intensifier and the input surface of Micro-channel plate(MCP). There are so many factors influencing the image intensifier performance, and the first proximity voltage is one of the most important factors that can not be ignored. Based on the theory analysis and test of different proximity voltage on the gain、signal-to-noise ratio and equivalent background noise, this test has studied on the important performance of Gen III image intensifier effected by the proximity voltage. By the experimental study, the increase of first proximity voltage to a certain extent can improve gain、signal-to-noise ratio and equivalent background noise at the same time. The main cause of this phenomenon is that the increase of proximity voltage can enlarge the incident electron energy, and then improve the quantum efficiency of the incident electron; meantime, stray electron produced by field emission at the action of the electric field of filmed-MCP will lead to equivalent background deterioration. Ultimately we conclude that: 1) Signal to noise is proportional to the square of he cathode sensitivity, increases with the first collision energy of the incident electron, especially at 200-500ev. 2)In the increasing process of voltage from 300v to 800v, the gain of filmed-MCP increases rapidly, but lower again when Upk increases further because of gain self-saturation; lgG and lgUpk are linear relationship, thus the curve can intuitively demonstrate the relationship between them. 3) Stray electron produced by field emission at the action of the electric field of filmed-MCP will lead to equivalent background deterioration, but will not exceed the requirements of technical specifications(2.5×10-7lx).

  20. 一起架空地线悬垂线夹挂轴磨损分析%Case Analysis of Suspension Clamp's Shaft Fracture of Overhead Ground Wire

    Institute of Scientific and Technical Information of China (English)

    黄修乾

    2011-01-01

    To solve the line tripping problem caused by the fracture of shaft on suspension clamp of the overhead ground wire of ihe 220 kV Marwan-Xkiaguan Line I , this paper analyzes (he size, texture of the suspension clamp and excludes the quality defect of suspension clamp, and by studying the line design parameters and plan & cross-section drawings, the geographical terrain and weather condition around the tripping location, the field equipment status, and the stress on suspension clamp, the reason of shaft fracture are discussed, li is concluded that the wind along the direction of line and the small vertical load from the suspension clamp are the main reasons leading to the abrasion of suspension clamp and fracture of the shaft. Countermeasures are proposed as precautions.%为解决220kV漫下I回线因架空地线悬垂线夹挂轴断裂引起的线路跳闸问题,通过分析悬垂线夹的尺寸、材质,排除了悬垂线夹存在质量问题;根据线路设计参数及平断面图、故障点地形及气象环境、故障现场设备状况和悬垂线夹受力情况,分析了挂轴断裂的原因,得出顺线路方向风的作用和悬垂线夹所受垂直荷载小是引起悬垂线夹挂轴磨损、断裂的主要原因,并有针对性的提出了相应防范措施.

  1. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    data are analyzed by software that implements the present machine-vision technique. This analysis results in the identification of cells that are "good" candidates for patch clamping (see figure). Once a "good" cell is identified, a patch clamp can be effected by an automated patchclamping apparatus or by a human operator. This technique has been shown to enable reliable identification of "good" and "bad" candidate cells for patch clamping. The ultimate goal in further development of this technique is to combine artificial-intelligence processing with instrumentation and controls in order to produce a complete "turnkey" automated patch-clamping system capable of accurately and reliably patch clamping cells with a minimum intervention by a human operator. Moreover, this technique can be adapted to virtually any cellular-analysis procedure that includes repetitive operation of microscope hardware by a human.

  2. Trends in Aortic Clamp Use During Coronary Artery Bypass Surgery: The Effect of Aortic Clamping Strategies on Neurologic Outcomes

    Science.gov (United States)

    Daniel, William T.; Kilgo, Patrick; Puskas, John D.; Thourani, Vinod H.; Lattouf, Omar M.; Guyton, Robert A.; Halkos, Michael E.

    2013-01-01

    Objective The purpose of this study was to determine the impact of different clamping strategies during CABG on the incidence of postoperative stroke. Methods In this case-control study, all patients at Emory hospitals from 2002–2009 with postoperative stroke after isolated CABG (N=141) were matched 1:4 to a contemporaneous cohort of patients without postoperative stroke (N=565). Patients were matched according to the Society of Thoracic Surgeons (STS) Predicted Risk of Postoperative Stroke (PROPS), which is based on 26 variables. On- (ONCAB) and off-pump (OPCAB) patients were matched separately. Multiple logistic regression analysis with adjusted odds ratios (OR) was performed to identify operative variables associated with postoperative stroke. Results Among the ONCAB cohort, the single cross-clamp technique was associated with a decreased risk of stroke compared to the double clamp (cross clamp + partial clamp) technique (OR=0.385, p=0.044). Within the OPCAB cohort, there was no significant difference in stroke according to clamp use. Epiaortic ultrasound of the ascending aorta increased from 45.3% in 2002 to 89.4% in 2009. From 2002–2009, clamp use decreased from 97.7% of cases to 72.7%. Conclusions During ONCAB, the use of a single cross-clamp compared to the double clamp technique decreases the risk of postoperative stroke. The use of any aortic clamp has decreased and epiaortic ultrasound use has increased from 2002–2009, indicating a change in operative technique and surgeon awareness of the potential complications associated with manipulation of the aorta. PMID:23477689

  3. Analysis of bias voltage scan data recorded with hybrid Timepix1 silicon pixel assemblies at the DESY testbeam

    CERN Document Server

    Maimon, Shir

    2014-01-01

    This report will present results from the analysis of bias voltage scans in Timepix1 testbeam data. Three assemblies of varying sensor thickness were used to collect data. The effect of the bias voltage on charge sharing, in particular cluster size, was investigated and found to have a significant impact. The effect of the bias voltage on energy collection was also studied, leading to estimates for the depletion voltage, donor concentration, mobility and resistivity of each assembly. Finally, the effect of the bias voltage on the two-hit cluster resolution and detection efficiency was investigated. This report contains extracts from a longer document (LCD-OPEN-2014-001).

  4. Robotic Partial Nephrectomy Using Robotic Bulldog Clamps

    OpenAIRE

    2011-01-01

    Background and Objectives: The need for a skilled assistant to perform hilar clamping during robotic partial nephrectomy is a potential limitation of the technique. We describe our experience using robotic bulldog clamps applied by the console surgeon for hilar clamping. Methods: A total of 60 consecutive patients underwent robotic partial nephrectomy, 30 using laparoscopic bulldog clamps applied by the assistant and 30 using robotic bulldog clamps applied with the robotic Prograsp instrument...

  5. Enhanced Buck-Boost Three-Level Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Tan, K. K.; Gao, F.; Chiang Loh, Poh

    2009-01-01

    In traditional three-level neutral-point-clamped (NPC) inverters, a major issue is capacitor voltage imbalance, which results in low order harmonics. The compensation of the capacitor voltages often require additional control complexity, which cannot be conveniently implemented. The "alternative ...

  6. Detailed Behavior Analysis for High Voltage Bidirectional Flyback Converter Driving DEAP Actuator

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    flyback based converter has been implemented. The parasitic elements have serious influence for the operation of the converter, especially in the high output voltage condition. The detailed behavior analysis has been performed considering the impact of the critical parasitic parameters. The converter has...

  7. Analysis of high voltage step-up nonisolated DC-DC boost converters

    Science.gov (United States)

    Alisson Alencar Freitas, Antônio; Lessa Tofoli, Fernando; Junior, Edilson Mineiro Sá; Daher, Sergio; Antunes, Fernando Luiz Marcelo

    2016-05-01

    A high voltage step-up nonisolated DC-DC converter based on coupled inductors suitable to photovoltaic (PV) systems applications is proposed in this paper. Considering that numerous approaches exist to extend the voltage conversion ratio of DC-DC converters that do not use transformers, a detailed comparison is also presented among the proposed converter and other popular topologies such as the conventional boost converter and the quadratic boost converter. The qualitative analysis of the coupled-inductor-based topology is developed so that a design procedure can be obtained, from which an experimental prototype is implemented to validate the theoretical assumptions.

  8. Inrush Transient Current Analysis and Suppression of Photovoltaic Grid-Connected Inverters During Voltage Sag

    DEFF Research Database (Denmark)

    Li, Zhongyu; Zhao, Rende; Xin, Zhen

    2016-01-01

    The Inrush Transient Current (ITC) in the output of the photovoltaic grid-connected inverters is usually generated when grid voltage sag occurs, which can trigger the protection of the grid-connected inverters, and even destroy the semiconductor switches. Then, the grid-connected inverters...... will thus fail to ride through the voltage sag and even further cause more serious grid faults. This paper analyzes the generation principle of ITC and explores its influence factors, upon which, the suppression approaches are presented. Simulation and experimental results validate the theoretical analysis...

  9. Thermal Stress Analysis of Medium-Voltage Converters for Smart Transformers

    DEFF Research Database (Denmark)

    Andresen, Markus; Ma, Ke; De Carne, Giovanni

    2017-01-01

    . To address this concern, this work conducts thermal stress analysis for a modular multilevel converter (MMC), which is a promising solution for the medium voltage stage of the ST. The focus is put on the mission profiles of the transformer and the impact on the thermal stress of power semiconductor devices....... Normal operation at different power levels and medium voltage grid faults in a feeder fed by a traditional transformer are considered as well as the electrical and the thermal stress of the disconnection and the reconnection procedures. For the validation, the thermal stress of one MMC cell is reproduced...

  10. Dynamic memory of a single voltage-gated potassium ion channel: A stochastic nonequilibrium thermodynamic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Kinshuk, E-mail: kbpchem@gmail.com [Department of Chemistry, University of Calcutta, 92 A.P.C. Road, Kolkata 700 009 (India)

    2015-05-14

    In this work, we have studied the stochastic response of a single voltage-gated potassium ion channel to a periodic external voltage that keeps the system out-of-equilibrium. The system exhibits memory, resulting from time-dependent driving, that is reflected in terms of dynamic hysteresis in the current-voltage characteristics. The hysteresis loop area has a maximum at some intermediate voltage frequency and disappears in the limits of low and high frequencies. However, the (average) dissipation at long-time limit increases and finally goes to saturation with rising frequency. This raises the question: how diminishing hysteresis can be associated with growing dissipation? To answer this, we have studied the nonequilibrium thermodynamics of the system and analyzed different thermodynamic functions which also exhibit hysteresis. Interestingly, by applying a temporal symmetry analysis in the high-frequency limit, we have analytically shown that hysteresis in some of the periodic responses of the system does not vanish. On the contrary, the rates of free energy and internal energy change of the system as well as the rate of dissipative work done on the system show growing hysteresis with frequency. Hence, although the current-voltage hysteresis disappears in the high-frequency limit, the memory of the ion channel is manifested through its specific nonequilibrium thermodynamic responses.

  11. Analysis of DC output voltage ripple in an electromagnetic doubly salient brushless DC generator

    Institute of Scientific and Technical Information of China (English)

    WANG Li; YAN Yangguang; CAO Xiaoqing; MENG Xiaoli

    2007-01-01

    Considering the salient pole and high magnetic nonlinearity of the electromagnetic doubly salient (EMDS)DC generator,a 12/8 pole prototype EMDS generator is designed and calculated using a 2-D finite element method (FEM).The phenomenon is analyzed and that the phase voltage wave changes between 120°and 180°.The influence of the exciting current and armature reaction on the DC voltage ripple of the generator is discussed in detail.and the nonlinear rules are gained that DC voltage rippie changes accordingly.The theoretical analysis is verified by the simulation and expefimental results.The results are helpful for the optimal design of the generator and the optimal control of excitingwinding.We conelude mat the filter-capacitance of the rectifier can be designed.

  12. Differential Evolution approach to Optimal Reactive Power Dispatch with Voltage Stability enhancement by Modal Analysis

    Directory of Open Access Journals (Sweden)

    J.Jithendranath

    2013-07-01

    Full Text Available This paper presents an evolutionary based algorithm for solving optimal reactive power dispatch problem in power system. The problem was designed as a Multi-Objective case with loss minimization and voltage stability as objectives. Generator terminal voltages, tap setting of transformers and reactive power generation of capacitor banks were taken as optimization variables. Modal analysis method is adopted to assess the voltage stability of system. The above presented problem was solved on basis of efficient and reliable technique among all evolutionary based algorithms, the Differential Evolution Technique. The proposed method has been tested on IEEE 30 bus system where the obtained results were found satisfactorily to a large extent that of reported earlier.

  13. Dynamic response characteristics analysis of the doubly-fed wind power system under grid voltage drop

    Science.gov (United States)

    Chen, Y.; Wang, J.; Wang, H. H.; Yang, L.; Chen, W.; Xu, Y. T.

    2016-08-01

    Double-fed induction generator (DFIG) is sensitive to the disturbances of grid, so the security and stability of the grid and the DFIG itself are under threat with the rapid increase of DFIG. Therefore, it is important to study dynamic response of the DFIG when voltage drop failure is happened in power system. In this paper, firstly, mathematical models and the control strategy about mechanical and electrical response processes is respectively introduced. Then through the analysis of response process, it is concluded that the dynamic response characteristics are related to voltage drop level, operating status of DFIG and control strategy adapted to rotor side. Last, the correctness of conclusion is validated by the simulation about mechanical and electrical response processes in different voltage levels drop and different DFIG output levels under DIgSILENT/PowerFactory software platform.

  14. A High Step-Down Interleaved Buck Converter with Active-Clamp Circuits for Wind Turbines

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2012-12-01

    Full Text Available In this paper, a high step-down interleaved buck coupled-inductor converter (IBCC with active-clamp circuits for wind energy conversion has been studied. In high step-down voltage applications, an IBCC can extend duty ratio and reduce voltage stresses on active switches. In order to reduce switching losses of active switches to improve conversion efficiency, a IBCC with soft-switching techniques is usually required. Compared with passive-clamp circuits, the IBCC with active-clamp circuits have lower switching losses and minimum ringing voltage of the active switches. Thus, the proposed IBCC with active-clamp circuits for wind energy conversion can significantly increase conversion efficiency. Finally, a 240 W prototype of the proposed IBCC with active-clamp circuits was built and implemented. Experimental results have shown that efficiency can reach as high as 91%. The proposed IBCC with active-clamp circuits is presented in high step-down voltage applications to verify the performance and the feasibility for energy conversion of wind turbines.

  15. Voltage-dependent motion of the catalytic region of voltage-sensing phosphatase monitored by a fluorescent amino acid.

    Science.gov (United States)

    Sakata, Souhei; Jinno, Yuka; Kawanabe, Akira; Okamura, Yasushi

    2016-07-05

    The cytoplasmic region of voltage-sensing phosphatase (VSP) derives the voltage dependence of its catalytic activity from coupling to a voltage sensor homologous to that of voltage-gated ion channels. To assess the conformational changes in the cytoplasmic region upon activation of the voltage sensor, we genetically incorporated a fluorescent unnatural amino acid, 3-(6-acetylnaphthalen-2-ylamino)-2-aminopropanoic acid (Anap), into the catalytic region of Ciona intestinalis VSP (Ci-VSP). Measurements of Anap fluorescence under voltage clamp in Xenopus oocytes revealed that the catalytic region assumes distinct conformations dependent on the degree of voltage-sensor activation. FRET analysis showed that the catalytic region remains situated beneath the plasma membrane, irrespective of the voltage level. Moreover, Anap fluorescence from a membrane-facing loop in the C2 domain showed a pattern reflecting substrate turnover. These results indicate that the voltage sensor regulates Ci-VSP catalytic activity by causing conformational changes in the entire catalytic region, without changing their distance from the plasma membrane.

  16. Breakdown Characteristic Analysis of Paper- Oil Insulation under AC and DC Voltage

    Science.gov (United States)

    Anuar, N. F.; Jamail, N. A. M.; Rahman, R. A.; Kamarudin, M. S.

    2017-08-01

    This paper presents the study of breakdown characteristic of Kraft paper insulated with two different types of insulating fluid, which are Palm oil and Coconut oil. Palm oil and Coconut oil are chosen as the alternative fluid to the transformer oil because it has high potential and environmentally-friendly. The Segezha Kraft papers with various thicknesses (65.5 gsm, 75 gsm, 85gsm, 90 gsm) have been used in this research. High Voltage Direct Current (HVDC), High Voltage Alternating Current (HVAC) and carbon track and severity analysis is conducted to observe the sample of aging Kraft paper. These samples have been immersed using Palm oil and Coconut oil up to 90 days to observe the absorption rate. All samples started to reach saturation level at 70 days of immersion. HVDC and HVAC breakdown experiments have been done after the samples had reached the saturation level based on normal condition, immersed in Palm oil and immersed in Coconut oil. All samples immersed in liquid show different breakdown voltage reading compared to normal condition. The analysis of carbon track and severity on surface has been done using Analytical Scanning Electron Microscope (SEM) Analysis. The results of the experiment show that the sample of Kraft paper immersed in Palm oil was better than Coconut oil immersed sample. Therefore the sample condition was the main factor that determines the value of breakdown voltage test. Introduction

  17. Analysis of bi-directional piezoelectric-based converters for zero-voltage switching operation

    DEFF Research Database (Denmark)

    Ekhtiari, Marzieh; Zhang, Zhe; Andersen, Michael A. E.

    2016-01-01

    This paper deals with a thorough analysis of zerovoltage switching especially for bi-directional, inductorless, piezoelectric transformer-based switch-mode power supplies with a half-bridge topology. Practically, obtaining zero-voltage switching for all of the switches in a bi......-directional piezoelectric power converter is a difficult task. However, the analysis in this work will be convenient for overcoming this challenge. The analysis defines the zero-voltage region indicating the operating points whether or not soft switching can be met over the switching frequency and load range. For the first...... time, a comprehensive analysis is provided, which can be used as a design guideline for applying control techniques in order to drive switches in piezoelectric transformer-based converters. This study further conveys the proposed method to the region where all the switches can obtain soft switching...

  18. Centruroides toxin, a selective blocker of surface Na+ channels in skeletal muscle: voltage-clamp analysis and biochemical characterization of the receptor.

    OpenAIRE

    Jaimovich, E.; Ildefonse, M; Barhanin, J; Rougier, O; Lazdunski, M

    1982-01-01

    This paper describes the effects of a toxin from the scorpion Centruroides suffusus suffusus on frog skeletal muscle. The main findings are the following, (i) Centruroides toxin (CssII) blocks the early phase of the inward sodium current in the muscle that arises from influx via Na+ channels in the surface membrane, but it does not affect the late phase of the inward current that represents flux through Na+ channels in the T-tubule membranes, (ii) CssII, in marked contrast to tetrodotoxin, do...

  19. Centruroides toxin, a selective blocker of surface Na+ channels in skeletal muscle: voltage-clamp analysis and biochemical characterization of the receptor.

    Science.gov (United States)

    Jaimovich, E; Ildefonse, M; Barhanin, J; Rougier, O; Lazdunski, M

    1982-06-01

    This paper describes the effects of a toxin from the scorpion Centruroides suffusus suffusus on frog skeletal muscle. The main findings are the following, (i) Centruroides toxin (CssII) blocks the early phase of the inward sodium current in the muscle that arises from influx via Na+ channels in the surface membrane, but it does not affect the late phase of the inward current that represents flux through Na+ channels in the T-tubule membranes, (ii) CssII, in marked contrast to tetrodotoxin, does not affect contraction of the muscle, (iii) Measurements of the binding of 125I-labeled CssII to a partially purified membrane preparation from the muscle indicate that the Kd of the CssII--receptor complex is approximately 0.4 nM. The half-life for the dissociation of this complex is 3 min at 22 degrees C and 16 min at 2 degrees C. Binding of the radiolabeled toxin varies markedly with pH and becomes insignificant at pH greater than 8.5. Proteolytic digestion of the membrane preparation decreases its ability to bind CssII, suggesting that the receptor is a protein. (iv) The number of binding sites for a radiolabeled derivative of tetrodotoxin on the membrane preparation was similar to that for CssII. However, neither tetrodotoxin nor any of seven other neurotoxins and some local anesthetics that alter the functioning of the Na+ channel have any effect on the binding of CssII to the muscle membrane. These results therefore indicate that CssII belongs to a different class of neurotoxins that has a different receptor on the Na+ channel.

  20. Clamp wins pipe repair prize

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-04-01

    This paper describes the permanent pipeline repair system, developed by Tekmar, which is powered by seawater hydraulics and is easily installed and tested by any workclass remotely operated vehicle (rov). Details are given of the two main components of the system, namely, the diverless high pressure split repair clamp and the rov-operated tool to install it.

  1. Automated planar patch-clamp.

    Science.gov (United States)

    Milligan, Carol J; Möller, Clemens

    2013-01-01

    Ion channels are integral membrane proteins that regulate the flow of ions across the plasma membrane and the membranes of intracellular organelles of both excitable and non-excitable cells. Ion channels are vital to a wide variety of biological processes and are prominent components of the nervous system and cardiovascular system, as well as controlling many metabolic functions. Furthermore, ion channels are known to be involved in many disease states and as such have become popular therapeutic targets. For many years now manual patch-clamping has been regarded as one of the best approaches for assaying ion channel function, through direct measurement of ion flow across these membrane proteins. Over the last decade there have been many remarkable breakthroughs in the development of technologies enabling the study of ion channels. One of these breakthroughs is the development of automated planar patch-clamp technology. Automated platforms have demonstrated the ability to generate high-quality data with high throughput capabilities, at great efficiency and reliability. Additional features such as simultaneous intracellular and extracellular perfusion of the cell membrane, current clamp operation, fast compound application, an increasing rate of parallelization, and more recently temperature control have been introduced. Furthermore, in addition to the well-established studies of over-expressed ion channel proteins in cell lines, new generations of planar patch-clamp systems have enabled successful studies of native and primary mammalian cells. This technology is becoming increasingly popular and extensively used both within areas of drug discovery as well as academic research. Many platforms have been developed including NPC-16 Patchliner(®) and SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich), CytoPatch™ (Cytocentrics AG, Rostock), PatchXpress(®) 7000A, IonWorks(®) Quattro and IonWorks Barracuda™, (Molecular Devices, LLC); Dynaflow(®) HT (Cellectricon

  2. Intravenous administration of lidocaine directly acts on spinal dorsal horn and produces analgesic effect: An in vivo patch-clamp analysis

    OpenAIRE

    Miyuki Kurabe; Hidemasa Furue; Tatsuro Kohno

    2016-01-01

    Intravenous lidocaine administration produces an analgesic effect in various pain states, such as neuropathic and acute pain, although the underlying mechanisms remains unclear. Here, we hypothesized that intravenous lidocaine acts on spinal cord neurons and induces analgesia in acute pain. We therefore examined the action of intravenous lidocaine in the spinal cord using the in vivo patch-clamp technique. We first investigated the effects of intravenous lidocaine using behavioural measures i...

  3. A Hybrid Cascade Converter Topology With Series-Connected Symmetrical and Asymmetrical Diode-Clamped H-Bridge Cells

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Ghosh, Arindam

    2011-01-01

    voltage with the same number of components. To balance the dc link capacitor voltages for the maximum output voltage resolution as well as synthesize asymmetrical dc link combination, a new multi-output boost converter is utilized at the dc link voltage of a seven-level H-bridge diode-clamped inverter......A novel H-bridge multilevel pulsewidth modulation converter topology based on a series connection of a high-voltage diode-clamped inverter and a low-voltage conventional inverter is proposed in this paper. A dc link voltage arrangement for the new hybrid and asymmetric solution is presented to have...... a maximum number of output voltage levels by preserving the adjacent switching vectors between voltage levels. Hence, a 15-level hybrid converter can be attained with a minimum number of power components. A comparative study has been carried out to present high performance of the proposed configuration...

  4. 三电平中点钳位电压型逆变器带不平衡负载时的复合控制策略%Integrate Control Strategy for Three-level Neutral-point Clamped Voltage Source Inverter with Unbalanced Load

    Institute of Scientific and Technical Information of China (English)

    肖飞; 谢桢; 吕昊

    2013-01-01

    In order to improve the wave of voltage, a delay signal cancel(DSC) method has been used to distinguish and control the positive and negative sequence components. However, while reinforcing the voltage waveform, the method increases the imbalance of the current, which results in seriously neutral-point voltage oscillating, under the space vector pulse width modulation (SVPWM). Thus, impact of the negative sequence current to neutral-point voltage oscillation is calculated. The results show that the neutral-point control ability could be increased or decreased with the negative sequence component increasing, which is mostly depended on the power factor. When the modulate proportion is bigger than 0. 5, the neutral-point control ability can be descend to zero because of the inconsonance between the power factor and negative sequence gene. Moreover, the boundary of the ability to control the unbalance by controlling the redundant voltage small vectors is found. Therefore the neutral-point control SVPWM is built. Plus, a integrate control strategy for three-level neutral-point clamped (NPC) voltage source inverter with unbalanced load based on distinguishing and controlling the positive and negative sequence components by DSC is put forward. Simulation exhibit that by the presented method, the negative sequence voltage can be restrained, and the negative sequence current makes the neutral-point unbalanced, while the voltage fluctuation at the neutral-point is controlled by the integrate control strategy. It is proved that under the integrated control strategy, three-level NPC voltage source inverter( VSI) performs well with unbalance load.%为了改善不平衡负载条件下三电平中点钳位型(NPC)电压型逆变器的输出电压波形,采用了延迟信号撤销法(DSC)分离出正序和负序电压分量分别进行控制.但此方法在修正了电压波形的同时,会进一步增加输出电流的不对称性,导致在空间矢量脉宽调制算法(SVPWM)

  5. Analysis of The Clamping Force for 2D Electro-hydraulic Rotary Valve%2D电液转阀式换向阀阀芯卡紧力分析

    Institute of Scientific and Technical Information of China (English)

    童成伟; 阮健; 孔晨菁; 刘奎

    2016-01-01

    Introduces the working principle of 2D electro-hydraulic rotary valve, and puts forward a design scheme of 2D electro-ydraulic rotary valve.Based on the principle of gap flow and analysis of the radial clamping force of the spool of 2D electro-hydraulic rotary valve un-der eccentric conditions,the theoretical calculation formula of the clamping force of the spool is obtained.Using MATLAB software to draw the relationship of spool radial clamping force with eccentric angle and the angle of high and low pressure groove.%介绍了2D电液转阀式换向阀的工作原理,提出了一种2D电液转阀式换向阀的设计方案;应用缝隙流动原理,对2D电液转阀式换向阀阀芯在偏心情况下的径向卡紧力进行系统理论分析,得到阀芯液压卡紧力的理论计算公式;运用MATLAB软件进行数值计算,得出阀芯径向卡紧力与偏心角位置和高低压槽口夹角的关系。

  6. Multifrequency Excitation of a Clamped-Clamped Microbeam

    KAUST Repository

    Jaber, Nizar R.

    2016-01-20

    We present analytical and experimental investigation of an electrically actuated clamped-clamped microbeam under a twosource harmonic excitation. The first frequency is swept around the first mode of vibration where the second one is fixed. These microbeams are fabricated using polyimide as structural layer coated with nickel form top and chromium and gold layers from bottom. We demonstrate the excitation of additive and subtractive type resonance. We show that by properly tuning the frequency and the amplitude of the excitation force, the frequency bandwidth of the resonator is increased. Theoretically, we solved the eigenvalue problem for different axial forces to find the natural frequencies ratio that match the experimental values. Using Galerkin method, a reduced order model is derived to simulate the static and dynamic response of the device where using three symmetric mode shapes provided a good agreement with experimental data. © Copyright 2015 by ASME.

  7. Note: High-efficiency energy harvester using double-clamped piezoelectric beams

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yingmei; Wu, Xuan; Parmar, Mitesh; Lee, Dong-weon, E-mail: mems@jnu.ac.kr [MEMS and Nanotechnology Laboratory, School of Mechanical Systems Engineering, Chonnam National University, Gwangju (Korea, Republic of)

    2014-02-15

    In this study, an improvement in energy conversion efficiency has been reported, which is realized by using a double-clamped piezoelectric beam, based on uniaxial stretching strain. The buckling mechanism is applied to maximize axial stress in the double-clamped beam. The voltage generated by using the double-clamped piezoelectric beam is higher than that generated by using other conventional structures, such as bending cantilevers coated/sandwiched with piezoelectric film, which is proven both theoretically and experimentally. The power generation efficiency is enhanced by further optimizing the double-clamped structure. The optimized high-efficiency energy harvester utilizing double-clamped piezoelectric beams generates a peak output power of 80 μW, under an acceleration of 0.1g.

  8. Note: high-efficiency energy harvester using double-clamped piezoelectric beams.

    Science.gov (United States)

    Zheng, Yingmei; Wu, Xuan; Parmar, Mitesh; Lee, Dong-weon

    2014-02-01

    In this study, an improvement in energy conversion efficiency has been reported, which is realized by using a double-clamped piezoelectric beam, based on uniaxial stretching strain. The buckling mechanism is applied to maximize axial stress in the double-clamped beam. The voltage generated by using the double-clamped piezoelectric beam is higher than that generated by using other conventional structures, such as bending cantilevers coated/sandwiched with piezoelectric film, which is proven both theoretically and experimentally. The power generation efficiency is enhanced by further optimizing the double-clamped structure. The optimized high-efficiency energy harvester utilizing double-clamped piezoelectric beams generates a peak output power of 80 μW, under an acceleration of 0.1g.

  9. Current voltage analysis and band diagram of Ti/TiO{sub 2} nanotubes Schottky junction

    Energy Technology Data Exchange (ETDEWEB)

    Mini, P.A.; Sherine, Alex; Shalumon, K.T.; Balakrishnan, Avinash; Nair, S.V.; Subramanian, K.R.V. [Amrita Vishwa Vidyapeetham (University), Amrita Centre for Nanosciences and Molecular Medicine, Kochi (India)

    2012-08-15

    Here, we report on how the energy band diagram of a nanostructured semiconductor- metal interface aligns in accordance with semiconductor morphology. Electrochemically, titanium metal is anodized to form titanium dioxide nanotubes, which forms a junction with the free Ti substrate and this junction forms a natural Schottky barrier. With reduced dimensionality of the nanotube structures (lower wall thickness), we have observed band edge movements and band gap quantum confinement effects and lowering of the Schottky barrier. These results were corroborated with the help of cyclic voltammetry, ultraviolet-visible spectrometry, and impedance analysis. Current voltage analysis of the Schottky barrier showed a lowering of the barrier (by 25 %) with reducing dimensionality of the nanotube structures. At externally applied voltages higher than the Schottky barrier, charges can travel along the nanotubes and reside at an interface between the nanotubes and a high-{kappa} dielectric. This property was utilized to develop high surface area solid-state capacitors. (orig.)

  10. Current voltage analysis and band diagram of Ti/TiO2 nanotubes Schottky junction

    Science.gov (United States)

    Mini, P. A.; Sherine, Alex; Shalumon, K. T.; Balakrishnan, Avinash; Nair, S. V.; Subramanian, K. R. V.

    2012-08-01

    Here, we report on how the energy band diagram of a nanostructured semiconductor- metal interface aligns in accordance with semiconductor morphology. Electrochemically, titanium metal is anodized to form titanium dioxide nanotubes, which forms a junction with the free Ti substrate and this junction forms a natural Schottky barrier. With reduced dimensionality of the nanotube structures (lower wall thickness), we have observed band edge movements and band gap quantum confinement effects and lowering of the Schottky barrier. These results were corroborated with the help of cyclic voltammetry, ultraviolet-visible spectrometry, and impedance analysis. Current voltage analysis of the Schottky barrier showed a lowering of the barrier (by 25 %) with reducing dimensionality of the nanotube structures. At externally applied voltages higher than the Schottky barrier, charges can travel along the nanotubes and reside at an interface between the nanotubes and a high- κ dielectric. This property was utilized to develop high surface area solid-state capacitors.

  11. State space analysis of boost DC/DC converter with voltage mode control

    Science.gov (United States)

    Shenoy, K. Latha; Nayak, C. Gurudas; Mandi, Rajashekar P.

    2017-07-01

    The boost converter belongs to the family of indirect energy transfer converters. The inductor stores energy during switch on and the output capacitor deliver power to the load. During switch off condition, the stored inductive energy appears in series with the input source and supply the output. The paper deals with the small signal analysis of dc-dc boost converter. It is used in modeling the closed loop converter parameters. The boost converter produces an undesirable Right-Half Plane Zero (RHPZ) in the small signal analysis due to which the implementation of voltage mode control needs attention. This requires compensating the regulator such that the crossover frequency occurs well below the frequency of the RHP zero. The paper describes modeling of voltage mode control boost converter operating in continuous conduction mode.

  12. Dynamic Stability Analysis of Autonomous Medium-Voltage Mixed-Source Microgrid

    DEFF Research Database (Denmark)

    Zhao, Zhuoli; Yang, Ping; Guerrero, Josep M.

    2015-01-01

    In an autonomous microgrid without connection to the interconnected grid to support the frequency and voltage, it is more complex to control and manage. Thus in order to investigate the dynamic stability of the medium-voltage (MV) microgrid in Dongao Island, a detailed small-signal state......-space model of the autonomous MV mixed-source microgrid containing diesel generator set (DGS), grid-supporting battery energy storage system (BESS), squirrel cage induction generator (SCIG) wind turbine and network is developed. Sensitivity analysis is carried out to reveal the dynamic stability margin...... of the MV microgrid and identify the permissible variations range of the droop coefficients. Finally, the theoretical analysis is verified with time-domain simulation and experimental results....

  13. Analysis of predictor factors of limb amputation in patients with high-voltage electrical burns

    Directory of Open Access Journals (Sweden)

    Guillermo García Álvarez

    2015-09-01

    Full Text Available Background: Limb amputation is considered one of the most devastating consequences of electrical injury. Any factors that correlate with the degree of muscle damage can be used to predict the necessity of limb amputation. The aim of this study was to determine the factors that can be used to predict limb amputation in high-voltage electrically injured patients. Methods: Eighty-two high-voltage electrically injured patients were admitted to the Department of Plastic and Reconstructive Surgery and Burns of National Arzobispo Loayza Hospital on a 5 year period. A retrospective analysis of the possible related risk factors between amputation and non-amputation patients was performed. Results: A total of 68 patients were enrolled for analysis. Thirteen patients underwent limb amputations. Multivariate analysis of the risk factors between amputation and non-amputation groups showed statistical significance for first 24 hour creatine kinase-isoenzyme MB (CKMB level. A serum CK-MB level above 14,955 U/L predicted high risk of limb amputation with high specificity (84% and sensitivity (77%. Only one patient with a remarkable decrease of creatine kinase (CPKt and CK-MB levels after fasciotomy avoided a major limb amputation. Conclusion: Our results suggest that CPK-MB level is an independent factor for prediction of limb amputation in patients with high-voltage electrical burns. We suggest that the addition of CPK-MB evaluation to clinical symptom screening may be a valuable method for early detection of muscle damage.

  14. Digital-circuit analysis of short-gate tunnel FETs for low-voltage applications

    Science.gov (United States)

    Zhuge, Jing; Verhulst, Anne S.; Vandenberghe, William G.; Dehaene, Wim; Huang, Ru; Wang, Yangyuan; Groeseneken, Guido

    2011-08-01

    This paper investigates the potential of tunnel field-effect transistors (TFETs), with emphasis on short-gate TFETs, by simulation for low-power digital applications having a supply voltage lower than 0.5 V. A transient study shows that the tunneling current has a negligible contribution in charging and discharging the gate capacitance of TFETs. In spite of a higher resistance region in the short-gate TFET, the gate (dis)charging speed still meets low-voltage application requirements. A circuit analysis is performed on short-gate TFETs with different materials, such as Si, Ge and heterostructures in terms of voltage overshoot, delay, static power, energy consumption and energy delay product (EDP). These results are compared to MOSFET and full-gate TFET performance. It is concluded that short-gate heterostructure TFETs (Ge-source for nTFET, In0.6Ga0.4As-source for pTFET) are promising candidates to extend the supply voltage to lower than 0.5 V because they combine the advantage of a low Miller capacitance, due to the short-gate structures, and strong drive current in TFETs, due to the narrow bandgap material in the source. At a supply voltage of 0.4 V and for an EOT and channel length of 0.6 nm and 40 nm, respectively, a three-stage inverter chain based on short-gate heterostructure TFETs saves 40% energy consumption per cycle at the same delay and shows 60%-75% improvement of EDP at the same static power, compared to its full-gate counterpart. When compared to the MOSFET, better EDP can be achieved in the heterostructure TFET especially at low static power consumption.

  15. Dynamic Study of a Capacitive MEMS Switch with Double Clamped-Clamped Microbeams

    Directory of Open Access Journals (Sweden)

    Hatem Samaali

    2014-01-01

    Full Text Available We study a capacitive MEMS switch composed of two clamped-clamped exible microbeams. We first develop a mathematical model for the MEMS switch where the upper microbeam represents the ground transmission line and the lower one represents the central transmission line. An electrostatic force is applied between the two microbeams to yield the switch to its ON and OFF states. We derive the equations of motion of the system and associated boundary conditions and solve the static and dynamic problems using the differential quadratic method. We show that using only nine grid points gives relatively accurate results when compared to those obtained using FEM. We also examine the transient behavior of the microswitch and obtain results indicating that subsequent reduction in actuation voltage, switching time, and power consumption are expected along with relatively good RF performances. ANSYS HFSS simulator is used in this paper to extract the RF characteristics of the microswitch. HFSS simulation results show that the insertion loss is as low as −0.31 dB and that the return loss is better than −12.41 dB at 10 GHz in the ON state. At the OFF state, the isolation is lower than −23 dB in the range of 10 to 50 GHz.

  16. Is early cord clamping, delayed cord clamping or cord milking best?

    Science.gov (United States)

    Vatansever, Binay; Demirel, Gamze; Ciler Eren, Elif; Erel, Ozcan; Neselioglu, Salim; Karavar, Hande Nur; Gundogdu, Semra; Ulfer, Gozde; Bahadir, Selcen; Tastekin, Ayhan

    2017-03-20

    To compare the antioxidant status of three cord clamping procedures (early clamping, delayed clamping and milking) by analyzing the thiol-disulfide balance. This randomized controlled study enrolled 189 term infants who were divided into three groups according to the cord clamping procedure: early clamping, delayed clamping and milking. Blood samples were collected from the umbilical arteries immediately after clamping, and the thiol/disulfide homeostasis was analyzed. The native and total thiol levels were significantly (p cord clamping group compared with the other two groups. The disulfide/total thiol ratio was significantly (p = .026) lower in the delayed cord clamping and milking groups compared with the early clamping groups. Early cord clamping causes the production of more disulfide bonds and lower thiol levels, indicating that oxidation reactions are increased in the early cord clamping procedure compared with the delayed cord clamping and milking procedures. The oxidant capacity is greater with early cord clamping than with delayed clamping or cord milking. Delayed cord clamping or milking are beneficial in neonatal care, and we suggest that they be performed routinely in all deliveries.

  17. Implementing dynamic clamp with synaptic and artificial conductances in mouse retinal ganglion cells.

    Science.gov (United States)

    Huang, Jin Y; Stiefel, Klaus M; Protti, Dario A

    2013-05-16

    Ganglion cells are the output neurons of the retina and their activity reflects the integration of multiple synaptic inputs arising from specific neural circuits. Patch clamp techniques, in voltage clamp and current clamp configurations, are commonly used to study the physiological properties of neurons and to characterize their synaptic inputs. Although the application of these techniques is highly informative, they pose various limitations. For example, it is difficult to quantify how the precise interactions of excitatory and inhibitory inputs determine response output. To address this issue, we used a modified current clamp technique, dynamic clamp, also called conductance clamp (1, 2, 3) and examined the impact of excitatory and inhibitory synaptic inputs on neuronal excitability. This technique requires the injection of current into the cell and is dependent on the real-time feedback of its membrane potential at that time. The injected current is calculated from predetermined excitatory and inhibitory synaptic conductances, their reversal potentials and the cell's instantaneous membrane potential. Details on the experimental procedures, patch clamping cells to achieve a whole-cell configuration and employment of the dynamic clamp technique are illustrated in this video article. Here, we show the responses of mouse retinal ganglion cells to various conductance waveforms obtained from physiological experiments in control conditions or in the presence of drugs. Furthermore, we show the use of artificial excitatory and inhibitory conductances generated using alpha functions to investigate the responses of the cells.

  18. An Impedance-Based Stability Analysis Method for Paralleled Voltage Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    This paper analyses the stability of paralleled voltage source converters in AC distributed power systems. An impedance-based stability analysis method is presented based on the Nyquist criterion for multiloop system. Instead of deriving the impedance ratio as usual, the system stability...... is assessed based on a series of Nyquist diagrams drawn for the terminal impedance of each converter. Thus, the effect of the right half-plane zeros of terminal impedances in the derivation of impedance ratio for paralleled source-source converters is avoided. The interaction between the terminal impedance...... of converter and the passive network can also be predicted by the Nyquist diagrams. This method is applied to evaluate the current and voltage controller interactions of converters in both grid-connected and islanded operations. Simulations and experimental results verify the effectiveness of theoretical...

  19. Voltage Stability Bifurcation Analysis for AC/DC Systems with VSC-HVDC

    Directory of Open Access Journals (Sweden)

    Yanfang Wei

    2013-01-01

    Full Text Available A voltage stability bifurcation analysis approach for modeling AC/DC systems with VSC-HVDC is presented. The steady power model and control modes of VSC-HVDC are briefly presented firstly. Based on the steady model of VSC-HVDC, a new improved sequential iterative power flow algorithm is proposed. Then, by use of continuation power flow algorithm with the new sequential method, the voltage stability bifurcation of the system is discussed. The trace of the P-V curves and the computation of the saddle node bifurcation point of the system can be obtained. At last, the modified IEEE test systems are adopted to illustrate the effectiveness of the proposed method.

  20. Design and analysis of a three-stage voltage-controlled ring oscillator

    Science.gov (United States)

    Xuemei, Lei; Zhigong, Wang; Lianfeng, Shen

    2013-11-01

    This paper describes a large tuning range low phase noise voltage-controlled ring oscillator (ring VCO) based on a different cascade voltage logic delay cell with current-source load to change the current of output node. The method for optimization is presented. Furthermore, the analysis of performance of the proposed ring VCO is confirmed by the measurement results. The three-stage proposed ring VCO was fabricated in the 180-nm CMOS process of SMIC. The measurement results show that the oscillator frequency of the ring VCO is from 0.770 to 5.286 GHz and the phase noise is 97.93 dBc/Hz at an offset of 1 MHz from 5.268 GHz with a total power of 15.1 mW from a 1.8 V supply while occupying only 0.00175 mm2 of the core die area.

  1. Intravenous administration of lidocaine directly acts on spinal dorsal horn and produces analgesic effect: An in vivo patch-clamp analysis.

    Science.gov (United States)

    Kurabe, Miyuki; Furue, Hidemasa; Kohno, Tatsuro

    2016-05-18

    Intravenous lidocaine administration produces an analgesic effect in various pain states, such as neuropathic and acute pain, although the underlying mechanisms remains unclear. Here, we hypothesized that intravenous lidocaine acts on spinal cord neurons and induces analgesia in acute pain. We therefore examined the action of intravenous lidocaine in the spinal cord using the in vivo patch-clamp technique. We first investigated the effects of intravenous lidocaine using behavioural measures in rats. We then performed in vivo patch-clamp recording from spinal substantia gelatinosa (SG) neurons. Intravenous lidocaine had a dose-dependent analgesic effect on the withdrawal response to noxious mechanical stimuli. In the electrophysiological experiments, intravenous lidocaine inhibited the excitatory postsynaptic currents (EPSCs) evoked by noxious pinch stimuli. Intravenous lidocaine also decreased the frequency, but did not change the amplitude, of both spontaneous and miniature EPSCs. However, it did not affect inhibitory postsynaptic currents. Furthermore, intravenous lidocaine induced outward currents in SG neurons. Intravenous lidocaine inhibits glutamate release from presynaptic terminals in spinal SG neurons. Concomitantly, it hyperpolarizes postsynaptic neurons by shifting the membrane potential. This decrease in the excitability of spinal dorsal horn neurons may be a possible mechanism for the analgesic action of intravenous lidocaine in acute pain.

  2. Loading dynamics of a sliding DNA clamp.

    KAUST Repository

    Cho, Won-Ki

    2014-05-22

    Sliding DNA clamps are loaded at a ss/dsDNA junction by a clamp loader that depends on ATP binding for clamp opening. Sequential ATP hydrolysis results in closure of the clamp so that it completely encircles and diffuses on dsDNA. We followed events during loading of an E. coli β clamp in real time by using single-molecule FRET (smFRET). Three successive FRET states were retained for 0.3 s, 0.7 s, and 9 min: Hydrolysis of the first ATP molecule by the γ clamp loader resulted in closure of the clamp in 0.3 s, and after 0.7 s in the closed conformation, the clamp was released to diffuse on the dsDNA for at least 9 min. An additional single-molecule polarization study revealed that the interfacial domain of the clamp rotated in plane by approximately 8° during clamp closure. The single-molecule polarization and FRET studies thus revealed the real-time dynamics of the ATP-hydrolysis-dependent 3D conformational change of the β clamp during loading at a ss/dsDNA junction.

  3. The RFC clamp loader: structure and function.

    Science.gov (United States)

    Yao, Nina Y; O'Donnell, Mike

    2012-01-01

    The eukaryotic RFC clamp loader couples the energy of ATP hydrolysis to open and close the circular PCNA sliding clamp onto primed sites for use by DNA polymerases and repair factors. Structural studies reveal clamp loaders to be heteropentamers. Each subunit contains a region of homology to AAA+ proteins that defines two domains. The AAA+ domains form a right-handed spiral upon binding ATP. This spiral arrangement generates a DNA binding site within the center of RFC. DNA enters the central chamber through a gap between the AAA+ domains of two subunits. Specificity for a primed template junction is achieved by a third domain that blocks DNA, forcing it to bend sharply. Thus only DNA with a flexible joint can bind the central chamber. DNA entry also requires a slot in the PCNA clamp, which is opened upon binding the AAA+ domains of the clamp loader. ATP hydrolysis enables clamp closing and ejection of RFC, completing the clamp loading reaction.

  4. Stability analysis and dynamic response of a DC-link module with a series voltage compensator

    DEFF Research Database (Denmark)

    Wang, Huai; Liu, Wenchao; Chung, Henry

    2013-01-01

    A DC-link module composed of a reduced value of DC-link capacitor and a series voltage compensator has been proposed. The voltage compensator processes the ripple voltage on the DC link and reactive power only, which can be implemented by low-voltage devices. The overall energy storage of the DC...

  5. Testing and analysis of tube voltage and tube current in the radiation generator for mammography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hong Ryang; Hong, Dong Hee [Dept. of Health Care, Hanseo University, Seosan (Korea, Republic of); Han, Beom Hui [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2014-03-15

    Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant , manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration 'about the safety of diagnostic radiation generator rule' specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

  6. Analysis of quinolones by voltage-assisted liquid-phase microextraction combined with LC-MS.

    Science.gov (United States)

    Wang, Mi-Hung; Wang, Shu-Ping

    2012-03-01

    The method of liquid-phase microextraction assisted with voltage was developed and applied on determination of quinolones in water sample in this study. Both of the reproducibility and extraction time were improved with the aid of applying voltage. Four analytes in neutral state such as cinoxacin, oxolinic acid, nalidixic acid, and flumequine were extracted from a sample solution at pH 2.0, through a polypropylene hollow fiber which was immobilized with 2-octanone, and then into a 25 μL of the acceptor phase of 40 mM borate buffer at pH 10.0 by applying voltage of 100 V. Subsequently, the acceptor solution was directly subjected to analysis by LC-MS. The performance of the method for four quinolones was also evaluated. Linearity was obtained in the range of 1.0-25.0 ng/mL with R(2) > 0.996. Limits of detection were below 0.6 ng/mL, and recoveries of water sample were ranged from 90.8 to 109.6%.

  7. CT x-ray tube voltage optimisation and image reconstruction evaluation using visual grading analysis

    Science.gov (United States)

    Zheng, Xiaoming; Kim, Ted M.; Davidson, Rob; Lee, Seongju; Shin, Cheongil; Yang, Sook

    2014-03-01

    The purposes of this work were to find an optimal x-ray voltage for CT imaging and to determine the diagnostic effectiveness of image reconstruction techniques by using the visual grading analysis (VGA). Images of the PH-5 CT abdomen phantom (Kagaku Co, Kyoto) were acquired by the Toshiba Aquillion One 320 slices CT system with various exposures (from 10 to 580 mAs) under different tube peak voltages (80, 100 and 120 kVp). The images were reconstructed by employing the FBP and the AIDR 3D iterative reconstructions with Mild, Standard and Strong FBP blending. Image quality was assessed by measuring noise, contrast to noise ratio and human observer's VGA scores. The CT dose index CTDIv was obtained from the values displayed on the images. The best fit for the curves of the image quality VGA vs dose CTDIv is a logistic function from the SPSS estimation. A threshold dose Dt is defined as the CTDIv at the just acceptable for diagnostic image quality and a figure of merit (FOM) is defined as the slope of the standardised logistic function. The Dt and FOM were found to be 5.4, 8.1 and 9.1 mGy and 0.47, 0.51 and 0.38 under the tube voltages of 80, 100 and 120 kVp, respectively, from images reconstructed by the FBP technique. The Dt and FOM values were lower from the images reconstructed by the AIDR 3D in comparison with the FBP technique. The optimal xray peak voltage for the imaging of the PH-5 abdomen phantom by the Aquillion One CT system was found to be at 100 kVp. The images reconstructed by the FBP are more diagnostically effective than that by the AIDR 3D but with a higher dose Dt to the patients.

  8. In vivo patch-clamp analysis of response properties of rat primary somatosensory cortical neurons responding to noxious stimulation of the facial skin

    Directory of Open Access Journals (Sweden)

    Nasu Masanori

    2010-05-01

    Full Text Available Abstract Background Although it has been widely accepted that the primary somatosensory (SI cortex plays an important role in pain perception, it still remains unclear how the nociceptive mechanisms of synaptic transmission occur at the single neuron level. The aim of the present study was to examine whether noxious stimulation applied to the orofacial area evokes the synaptic response of SI neurons in urethane-anesthetized rats using an in vivo patch-clamp technique. Results In vivo whole-cell current-clamp recordings were performed in rat SI neurons (layers III-IV. Twenty-seven out of 63 neurons were identified in the mechanical receptive field of the orofacial area (36 neurons showed no receptive field and they were classified as non-nociceptive (low-threshold mechanoreceptive; 6/27, 22% and nociceptive neurons. Nociceptive neurons were further divided into wide-dynamic range neurons (3/27, 11% and nociceptive-specific neurons (18/27, 67%. In the majority of these neurons, a proportion of the excitatory postsynaptic potentials (EPSPs reached the threshold, and then generated random discharges of action potentials. Noxious mechanical stimuli applied to the receptive field elicited a discharge of action potentials on the barrage of EPSPs. In the case of noxious chemical stimulation applied as mustard oil to the orofacial area, the membrane potential shifted depolarization and the rate of spontaneous discharges gradually increased as did the noxious pinch-evoked discharge rates, which were usually associated with potentiated EPSP amplitudes. Conclusions The present study provides evidence that SI neurons in deep layers III-V respond to the temporal summation of EPSPs due to noxious mechanical and chemical stimulation applied to the orofacial area and that these neurons may contribute to the processing of nociceptive information, including hyperalgesia.

  9. Analysis on Fault Current Limitation and Self-recovery of MMC Based on Clamp Double Sub-module%基于钳位双子模块的 MMC 故障清除和重启能力分析

    Institute of Scientific and Technical Information of China (English)

    丁云芝; 苏建徽; 周建

    2014-01-01

    针对当前已投入运行的高压直流(HVDC)输电工程中模块化多电平换流器(MMC)不具备直流侧故障电流闭锁能力的问题,分析了一种可自清除直流侧故障电流并且可重启动的 MMC 拓扑---基于钳位双子模块的 MMC。这种拓扑可在发生直流故障时通过闭锁所有绝缘栅双极型晶体管(IGBT)的触发信号和利用二极管的反向阻断能力迅速完成闭锁过程,从而达到无需交流断路器动作实现清除直流故障的目的。这种拓扑将半桥模块化 MMC 的调制方法和控制策略与可清除直流故障能力结合在一起,且具有结构简单、造价经济等特点。通过对半桥模块化 MMC 和钳位双子模块 MMC 在直流侧双极短路故障情况下的故障电流进行分析和仿真,验证了基于钳位双子模块的 MMC 在处理直流侧故障方面的能力和效果。%In view of the inability of the modular multilevel converter (MMC) in the high voltage direct current (HVDC) transmission projects in current operation to lock fault current on the DC side,an MMC topology based on clamp double sub-module(CDSM)capable of automatically eliminating and restarting the fault current on the DC side is analyzed.Because of the reverse blocking of diodes,blocking during a DC fault is achieved by blocking all the impulses of IGBTs,then the DC fault is eliminated without the action of AC breakers.Simple in structure and economical,this topology combines the modulation and the control strategy of MMC based on half bridge sub-module(HBSM-MMC)with the ability of recovering from a DC fault.A comparison with the HBSM-MMC in the case of a DC pole-to-pole fault by simulation and analysis has proved the performance of MMC based on CDSM in the control of DC fault current.

  10. Application of Numerical Simulation for the Verification of Design of Clamping a Workpiece in Jaws

    Science.gov (United States)

    Oravcová, Jarmila; Riečičiarová, Eva

    2016-12-01

    This paper deals with the use of the numerical computer oriented method for the analysis and verification of the design of workpiece clamping. The inaccuracies of the positioning in clamping locating points were simulated using the FEM software ANSYS. The influence of inaccuracies in the positions of contact locating points on the displacements of the workpiece characteristic points and their position in clamped removable jaws was examined. The reaction forces in the contact locating points were also computed and analyzed.

  11. Estimation of Transformer Parameters and Loss Analysis for High Voltage Capacitor Charging Application

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Schneider, Henrik; Ouyang, Ziwei

    2013-01-01

    In a bi-directional DC-DC converter for capacitive charging application, the losses associated with the transformer makes it a critical component. In order to calculate the transformer losses, its parameters such as AC resistance, leakage inductance and self capacitance of the high voltage (HV......) winding has to be estimated accurately. This paper analyzes the following losses of bi-directional flyback converter namely switching loss, conduction loss, gate drive loss, transformer core loss, and snubber loss, etc. Iterative analysis of transformer parameters viz., AC resistance, leakage inductance...

  12. Five-Level Active-Neutral-Point-Clamped DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2016-01-01

    reliability. Furthermore, a capacitor voltage control strategy by alternating two operation modes of the proposed modulation strategy is proposed to balance the voltage of the flying capacitor, which ensures multi-level voltages producing. Finally, the performance of the proposed converter and control......Multi-level converters are getting more and more attentions because of their obvious merits such as lower voltage stress and harmonic, smaller size of output filters, and so on. In this paper, a five-level active-neutral-point-clamped (5L-ANPC) dc/dc converter is proposed for power transfer...

  13. Mechanism of ATP-driven PCNA clamp loading by S. cerevisiae RFC.

    Science.gov (United States)

    Chen, Siying; Levin, Mikhail K; Sakato, Miho; Zhou, Yayan; Hingorani, Manju M

    2009-05-08

    Circular clamps tether polymerases to DNA, serving as essential processivity factors in genome replication, and function in other critical cellular processes as well. Clamp loaders catalyze clamp assembly onto DNA, and the question of how these proteins construct a topological link between a clamp and DNA, especially the mechanism by which ATP is utilized for the task, remains open. Here we describe pre-steady-state analysis of ATP hydrolysis, proliferating cell nuclear antigen (PCNA) clamp opening, and DNA binding by Saccharomyces cerevisiae replication factor C (RFC), and present the first kinetic model of a eukaryotic clamp-loading reaction validated by global data analysis. ATP binding to multiple RFC subunits initiates a slow conformational change in the clamp loader, enabling it to bind and open PCNA and to bind DNA as well. PCNA opening locks RFC into an active state, and the resulting RFC.ATP.PCNA((open)) intermediate is ready for the entry of DNA into the clamp. DNA binding commits RFC to ATP hydrolysis, which is followed by PCNA closure and PCNA.DNA release. This model enables quantitative understanding of the multistep mechanism of a eukaryotic clamp loader and furthermore facilitates comparative analysis of loaders from diverse organisms.

  14. Whole-cell clamp of dissociated photoreceptors from the eye of Lima scabra.

    Science.gov (United States)

    Nasi, E

    1991-01-01

    Voltage-dependent membrane currents were investigated in enzymatically dissociated photoreceptors of Lima scabra using the whole-cell clamp technique. Depolarizing steps to voltages more positive than -10 mV elicit a transient inward current followed by a delayed, sustained outward current. The outward current is insensitive to replacement of a large fraction of extracellular Cl- with the impermeant anion glucuronate. Superfusion with tetraethylammonium and 4-aminopyridine reversibly abolishes the outward current, and internal perfusion with cesium also suppresses it, indicating that it is mediated by potassium channels. Isolation of the inward current reveals a fast activation kinetics, the peak amplitude occurring as early as 4-5 ms after stimulus onset, and a relatively rapid, though incomplete inactivation. Within the range of voltages examined, spanning up to +90 mV, reversal was not observed. The inward current is not sensitive to tetrodotoxin at concentrations up to 10 microM, and survives replacement of extracellular Na with tetramethylammonium. On the other hand, it is completely eliminated by calcium removal from the perfusing solution, and it is partially blocked by submillimolar concentrations of cadmium, suggesting that it is entirely due to voltage-dependent calcium channels. Analysis of the kinetics and voltage dependence of the isolated calcium current indicates the presence of two components, possibly reflecting the existence of separate populations of channels. Barium and strontium can pass through these channels, though less easily than calcium. Both the activation and the inactivation become significantly more sluggish when these ions serve as the charge carrier. A large fraction of the outward current is activated by preceding calcium influx. Suppression of this calcium-dependent potassium current shows a small residual component resembling the delayed rectifier. In addition, a transient outward current sensitive to 4-aminopyridine (Ia) could

  15. A voltage-dependent persistent sodium current in mammalian hippocampal neurons

    OpenAIRE

    1990-01-01

    Currents generated by depolarizing voltage pulses were recorded in neurons from the pyramidal cell layer of the CA1 region of rat or guinea pig hippocampus with single electrode voltage-clamp or tight- seal whole-cell voltage-clamp techniques. In neurons in situ in slices, and in dissociated neurons, subtraction of currents generated by identical depolarizing voltage pulses before and after exposure to tetrodotoxin revealed a small, persistent current after the transient current. These curren...

  16. Stability Analysis and Controller Synthesis for Single-Loop Voltage-Controlled VSIs

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Loh, Poh Chiang; Blaabjerg, Frede

    2017-01-01

    This paper analyzes the stability of the digital single-loop voltage-controlled Voltage-Source Inverters (VSIs) using linear voltage regulators. It reveals that the phase lags caused by using the resonant controller and the time delay of digital control system can stabilize the voltage loop without...... damping of the LC-filter resonance. The stability region for the digital single-loop resonant voltage control is then identified considering the effects of the discretization methods applied to the resonant controller. An enhanced voltage control scheme with widened stability region is subsequently...

  17. Accelerated commutation for passive clamp isolated boost converters

    OpenAIRE

    2002-01-01

    An efficient and cost effective bidirectional DC/DC converter reduces switch voltage stress via accelerated commutation allowing use of a low-cost passive clamp circuit in boost mode. The converter includes a primary circuit, transformer and secondary circuit. The primary circuit takes the form of a “full bridge converter,” a “push-pull converter,” or an “L-type converter.”. The primary circuit may include a dissipator such as a snubber circuit or small buck converter. A secondary side of the...

  18. Influence of squeeze film damping on the higher-order modes of clamped–clamped microbeams

    KAUST Repository

    Alcheikh, N

    2016-05-06

    This paper presents an experimental study and a finite-element analysis of the effect of squeeze film damping on the resonance frequency and quality factor of the higher-order flexure vibrations modes of clamped-clamped microbeams. Viscoelastic and silicon nitride microbeams are fabricated and are electrostatically actuated by various electrode configurations to trigger the first, second, and third modes. The damping characteristic and the resonance frequency of these modes are examined for a wide range of gas pressure and electrostatic voltage loads. The results of the silicon nitride beams and viscoelastic beams are compared. It is found that the intrinsic material loss is the major dissipation mechanism at low pressure for the viscoelastic microbeams, significantly limiting their quality factor. It is also found that while the silicon nitride beams show higher quality factors at the intrinsic and molecular regimes of pressure, due to their low intrinsic loss, their quality factors near atmospheric pressure are lower than those of the viscoelastic microbeams. Further, the higher-order modes of all the beams show much higher quality factors at atmospheric pressure compared to the first mode, which could be promising for operating such resonators in air. Experimental results and finite element model simulations show good agreement for resonance frequency and quality factor for the three studied modes. © 2016 IOP Publishing Ltd.

  19. Coupling/Tradeoff Analysis and Novel Containment Control for Reactive Power, Output Voltage in Islanded Micro-Grid

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Guerrero, Josep M.

    2016-01-01

    and voltage magnitudes are provided specifically. In the secondary level, the tradeoffs between accurate reactive power sharing and voltage magnitudes regulation are further detailed. The analysis results can provide a guideline for the design of MG structure and its control parameters. In addition, a novel...... containment-based controller is proposed to control the voltage into a reasonable range which is the first time to apply this algorithm in MG. Furthermore, dynamic-consensus-based controller is used to guarantee accurate reactive power sharing. The combination of controllers offers a coordinated distributed...

  20. Implementation of a fast 16-Bit dynamic clamp using LabVIEW-RT.

    Science.gov (United States)

    Kullmann, Paul H M; Wheeler, Diek W; Beacom, Joshua; Horn, John P

    2004-01-01

    The dynamic-clamp method provides a powerful electrophysiological tool for creating virtual ionic conductances in living cells and studying their influence on membrane potential. Here we describe G-clamp, a new way to implement a dynamic clamp using the real-time version of the Lab-VIEW programming environment together with a Windows host, an embedded microprocessor that runs a real-time operating system and a multifunction data-acquisition board. The software includes descriptions of a fast voltage-dependent sodium conductance, delayed rectifier, M-type and A-type potassium conductances, and a leak conductance. The system can also read synaptic conductance waveforms from preassembled data files. These virtual conductances can be reliably implemented at speeds LabVIEW should make it relatively easy for others to adapt G-clamp for new experimental applications.

  1. MATLAB implementation of a dynamic clamp with bandwidth >125 KHz capable of generating INa at 37°C

    Science.gov (United States)

    Clausen, Chris; Valiunas, Virginijus; Brink, Peter R.; Cohen, Ira S.

    2012-01-01

    We describe the construction of a dynamic clamp with bandwidth >125 KHz that utilizes a high performance, yet low cost, standard home/office PC interfaced with a high-speed (16 bit) data acquisition module. High bandwidth is achieved by exploiting recently available software advances (code-generation technology, optimized real-time kernel). Dynamic-clamp programs are constructed using Simulink, a visual programming language. Blocks for computation of membrane currents are written in the high-level matlab language; no programming in C is required. The instrument can be used in single- or dual-cell configurations, with the capability to modify programs while experiments are in progress. We describe an algorithm for computing the fast transient Na+ current (INa) in real time, and test its accuracy and stability using rate constants appropriate for 37°C. We then construct a program capable of supplying three currents to a cell preparation: INa, the hyperpolarizing-activated inward pacemaker current (If), and an inward-rectifier K+ current (IK1). The program corrects for the IR drop due to electrode current flow, and also records all voltages and currents. We tested this program on dual patch-clamped HEK293 cells where the dynamic clamp controls a current-clamp amplifier and a voltage-clamp amplifier controls membrane potential, and current-clamped HEK293 cells where the dynamic clamp produces spontaneous pacing behavior exhibiting Na+ spikes in otherwise passive cells. PMID:23224681

  2. A model based DC analysis of SiPM breakdown voltages

    CERN Document Server

    Nagy, Ferenc; Kalinka, Gabor; Molnar, Jozsef

    2016-01-01

    A new method to determine the breakdown voltage of SiPMs is presented. It is backed up by a DC model which describes the breakdown phenomenon by distinct avalanche turn-on ($V_{01}$) and turn off ($V_{10}$) voltages. It is shown that $V_{01}$ is related to the 'breakdown voltage' that previous DC methods derive from simple reverse current-voltage measurements, while $V_{10}$ is the 'real' breakdown voltage commonly obtained from complex gain-voltage measurements. The proposed method reveals how the microcell population distributes around $V_{01}$ and $V_{10}$. It is found that if this distribution is assumed to be normal, then both voltages and even their standard deviation can readily be extracted from current-voltage curves. Measurements are in good agreement with the theoretical model.

  3. Design and Analysis of a Slope Voltage Control for a DFIG Wind Power Plant

    DEFF Research Database (Denmark)

    Martínez, J.; Kjær, P. C.; Rodriguez, Pedro

    2012-01-01

    This paper addresses a detailed design of a wind power plant and turbine slope voltage control in the presence of communication delays for a wide short-circuit ratio range operation. The implemented voltage control scheme is based upon the secondary voltage control concept, which offers fast...

  4. Five-Level Active-Neutral-Point-Clamped DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    Multi-level converters are getting more and more attentions because of their obvious merits such as lower voltage stress and harmonic, smaller size of output filters, and so on. In this paper, a five-level active-neutral-point-clamped (5L-ANPC) dc/dc converter is proposed for power transfer...

  5. Trans-Z-source and Γ-Z-source neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    Z-source neutral-point-clamped (NPC) inverters are earlier proposed for obtaining voltage buck-boost and three-level switching simultaneously. Their performances are, however, constrained by a trade-off between their input-to-output gain and modulation ratio. This trade-off can lead to high...

  6. Analysis on electrical characteristics of high-voltage GaN-based light-emitting diodes

    Institute of Scientific and Technical Information of China (English)

    Guo Wei-Ling; Yan Wei-Wei; Zhu Yan-Xu; Liu Jian-Peng; Ding Yan; Cui De-Sheng; Wu Guo-Qing

    2012-01-01

    In order to investigate their electrical characteristics,high-voltage light-emitting-diodes (HV-LEDs) each containing four cells in series are fabricated.The electrical parameters including varying voltage and parasitic effect are studied.It is shown that the ideality factors (IFs) of the HV-LEDs with different numbers of cells are 1.6,3.4,4.7,and 6.4.IF increases linearly with the number of cells increasing.Moreover,the performance of the HV-LED with failure cells is examined.The analysis indicates that the failure cell has a parallel resistance which induces the leakage of the failure cell.The series resistance of the failure cell is 76.8 Ω,while that of the normal cell is 21.3 Ω.The scanning electron microscope (SEM) image indicates that different metal layers do not contact well.It is hard to deposit the metal layers in the deep isolation trenches.The fabrication process of HV-LEDs needs to be optimized.

  7. Analysis of doubly-fed induction machine operating at motoring mode subjected to voltage sag

    Directory of Open Access Journals (Sweden)

    Navneet Kumar

    2016-09-01

    Full Text Available Variable Speed (VS Pumped Storage Plants (PSP equipped with large asynchronous (Doubly-Fed Induction machines are emerging now in hydropower applications. Motoring mode of operation of Doubly-Fed Induction Machine (DFIM is essential and techno-economical in this application due to: (1 its uniqueness in active power controllability, (2 bulk power handing capability with less rated power converters in rotor circuit, and (3 integrating Renewable Energy Sources (RES. This paper investigates the performance of two DFIMs at different power ratings (2.2 kW and 2 MW under voltage sag with different attribute. The test results are analyzed in terms of the peaks in torque, speed, power taken and transient currents in rotor and stator circuits. During sag, stable region for DFIM operation along with speed and stator side reactive power input control is also illustrated. The negative effects of voltage sag are briefly discussed. MATLAB simulation is validated with experimentation. The various observations during simulation and experimental analysis are also supported by the theoretical explanations.

  8. Measuring Electrolyte Impedance and Noise Simultaneously by Triangular Waveform Voltage and Principal Component Analysis.

    Science.gov (United States)

    Xu, Shanzhi; Wang, Peng; Dong, Yonggui

    2016-04-22

    In order to measure the impedance variation process in electrolyte solutions, a method of triangular waveform voltage excitation is investigated together with principal component analysis (PCA). Using triangular waveform voltage as the excitation signal, the response current during one duty cycle is sampled to construct a measurement vector. The measurement matrix is then constructed by the measurement vectors obtained from different measurements. After being processed by PCA, the changing information of solution impedance is contained in the loading vectors while the response current and noise information is contained in the score vectors. The measurement results of impedance variation by the proposed signal processing method are independent of the equivalent impedance model. The noise-induced problems encountered during equivalent impedance calculation are therefore avoided, and the real-time variation information of noise in the electrode-electrolyte interface can be extracted at the same time. Planar-interdigitated electrodes are experimentally tested for monitoring the KCl concentration variation process. Experimental results indicate that the measured impedance variation curve reflects the changing process of solution conductivity, and the amplitude distribution of the noise during one duty cycle can be utilized to analyze the contact conditions of the electrode and electrolyte interface.

  9. Measuring Electrolyte Impedance and Noise Simultaneously by Triangular Waveform Voltage and Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Shanzhi Xu

    2016-04-01

    Full Text Available In order to measure the impedance variation process in electrolyte solutions, a method of triangular waveform voltage excitation is investigated together with principal component analysis (PCA. Using triangular waveform voltage as the excitation signal, the response current during one duty cycle is sampled to construct a measurement vector. The measurement matrix is then constructed by the measurement vectors obtained from different measurements. After being processed by PCA, the changing information of solution impedance is contained in the loading vectors while the response current and noise information is contained in the score vectors. The measurement results of impedance variation by the proposed signal processing method are independent of the equivalent impedance model. The noise-induced problems encountered during equivalent impedance calculation are therefore avoided, and the real-time variation information of noise in the electrode-electrolyte interface can be extracted at the same time. Planar-interdigitated electrodes are experimentally tested for monitoring the KCl concentration variation process. Experimental results indicate that the measured impedance variation curve reflects the changing process of solution conductivity, and the amplitude distribution of the noise during one duty cycle can be utilized to analyze the contact conditions of the electrode and electrolyte interface.

  10. Comparison of the quantitative analysis performance between pulsed voltage atom probe and pulsed laser atom probe.

    Science.gov (United States)

    Takahashi, J; Kawakami, K; Raabe, D

    2017-01-31

    The difference in quantitative analysis performance between the voltage-mode and laser-mode of a local electrode atom probe (LEAP3000X HR) was investigated using a Fe-Cu binary model alloy. Solute copper atoms in ferritic iron preferentially field evaporate because of their significantly lower evaporation field than the matrix iron, and thus, the apparent concentration of solute copper tends to be lower than the actual concentration. However, in voltage-mode, the apparent concentration was higher than the actual concentration at 40K or less due to a detection loss of matrix iron, and the concentration decreased with increasing specimen temperature due to the preferential evaporation of solute copper. On the other hand, in laser-mode, the apparent concentration never exceeded the actual concentration, even at lower temperatures (20K), and this mode showed better quantitative performance over a wide range of specimen temperatures. These results indicate that the pulsed laser atom probe prevents both detection loss and preferential evaporation under a wide range of measurement conditions.

  11. Synchronization analysis of voltage-sensitive dye imaging during focal seizures in the rat neocortex

    Science.gov (United States)

    Takeshita, Daisuke; Bahar, Sonya

    2011-12-01

    Seizures are often assumed to result from an excess of synchronized neural activity. However, various recent studies have suggested that this is not necessarily the case. We investigate synchronization during focal neocortical seizures induced by injection of 4-aminopyridine (4AP) in the rat neocortex in vivo. Neocortical activity is monitored by field potential recording and by the fluorescence of the voltage-sensitive dye RH-1691. After removal of artifacts, the voltage-sensitive dye (VSD) signal is analyzed using the nonlinear dynamics-based technique of stochastic phase synchronization in order to determine the degree of synchronization within the neocortex during the development and spread of each seizure event. Results show a large, statistically significant increase in synchronization during seizure activity. Synchrony is typically greater between closer pixel pairs during a seizure event; the entire seizure region is synchronized almost exactly in phase. This study represents, to our knowledge, the first application of synchronization analysis methods to mammalian VSD imaging in vivo. Our observations indicate a clear increase in synchronization in this model of focal neocortical seizures across a large area of the neocortex; a sharp increase in synchronization during seizure events was observed in all 37 seizures imaged. The results are consistent with a recent computational study which simulates the effect of 4AP in a neocortical neuron model.

  12. Phase noise analysis of voltage controlled oscillator used in cesium atomic clock

    Science.gov (United States)

    Zhi, Menghui; Tang, Liang; Qiao, Donghai

    2017-03-01

    Coherent population trapping (CPT) cesium frequency standard plays a significant role in precision guidance of missile and global positioning system (GPS). Low noise 4.596 GHz voltage controlled oscillator (VCO) is an indispensable part of microwave signal source in cesium frequency standard. Low-phase noise is also the most important and difficult performance indicator of VCO. Starting from phase noise analysis method proposed by Leeson, the formulas about the relationship between phase noise of output signal of oscillator feedback model and phase fluctuation spectrum of amplifier, phase noise of oscillator are derived in this paper. Finally, the asymptote model of microwave oscillator is proposed based on the formula derivation. The experiment shows that when the reverse bias voltage of variode is 1.8 V, the designed oscillation frequency of VCO is 4.596 GHz, the power is ‑1 dBm and the DC power consumption is 19.6 mW. The tendency of phase noise simulation curve and actual test curve conform to asymptote model. The phase noise in 1 and 10 kHz is, respectively, ‑60.86 and ‑86.58 dBc/Hz. The significance of the paper lies in determining the main factors influencing oscillator phase noise and providing guiding direction for the design of low-phase noise VCO.

  13. Reliability analysis for the 220 kV Libyan high voltage communication system

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, O.S.A.; AlAthram, A.Y. [General Electric Company of Libya (Libyan Arab Jamahiriya). Development Dept.

    2007-07-01

    Electric utilities are expanding their networks to include fiber-optic communications, which offer high capacity with reliable performance at low cost. Fiber-optic networks offer a feasible technical solution for leasing excess capacity. They can be readily deployed under a wide range of network configurations and can be upgraded rapidly. This study evaluated the reliability index for the communication network of Libya's 220 kV high voltage subsystem operated by the General Electric Company of Libya (GECOL). The schematic diagrams of the communication networks were presented for both power line carriers and fiber optics networks. A reliability analysis for the two communication networks was performed through the existing communication equipment. The reliability values revealed that the fiber optics system has several advantages such as a large bandwidth for high quality data transmission; immunity to electromagnetic interference; low attenuation which allows for extended cable transmission; ability to be used in dangerous environments; a higher degree of security; and, a high capacity through existing conduits due to its light weight and small diameter. However, it was noted that although fiber optic communications may be more reliable and provide the clearest signal, the powerline communication (PLC) system has more redundancy, particularly in the case of outdoor components where the PLC has more power line to carry the signals, while the fiber optic communications depend only on the earthing wire of the high voltage transmission line. 4 refs., 8 tabs., 6 figs.

  14. Stability Analysis and Controller Synthesis for Digital Single-Loop Voltage-Controlled Inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Loh, Poh Chiang; Blaabjerg, Frede

    2016-01-01

    This paper analyzes first the stability of single-loop digital voltage control scheme for the LC-filtered voltage source inverters. It turns out that the phase lag, caused by the time delay of digital control system and by the use of integral controller, can stabilize the voltage loop without...... damping of LC-filter resonance. The stability regions are then identified with alternative voltage controller synthesized. For further widening the stability region, an active damping approach is proposed and co-designed with the voltage controller in the discrete z-domain. Simulations and experimental...

  15. Integral transform solutions of dynamic response of a clamped-clamped pipe conveying fluid

    Energy Technology Data Exchange (ETDEWEB)

    Gu Jijun; An Chen [Ocean Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68508, Rio de Janeiro 21941-972 (Brazil); Duan Menglan [Offshore Oil/Gas Research Center, China University of Petroleum, Beijing 102249 (China); Levi, Carlos [Ocean Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68508, Rio de Janeiro 21941-972 (Brazil); Su Jian, E-mail: sujian@nuclear.ufrj.br [Nuclear Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68509, Rio de Janeiro 21941-972 (Brazil)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer Dynamic response of pipe conveying fluid was studied numerically. Black-Right-Pointing-Pointer The generalized integral transform technique (GITT) was applied. Black-Right-Pointing-Pointer Numerical solutions with automatic global accuracy control were obtained. Black-Right-Pointing-Pointer Excellent convergence behavior was shown. Black-Right-Pointing-Pointer Modal separation analysis was carried out and the influence of mass ratio was analyzed. - Abstract: Analysis of dynamic response of pipe conveying fluid is an important aspect in nuclear power plant design. In the present paper, dynamic response of a clamped-clamped pipe conveying fluid was solved by the generalized integral transform technique (GITT). The governing partial differential equation was transformed into a set of second-order ordinary differential equations which is then numerically solved by making use of the subroutine DIVPAG from IMSL Library. A thorough convergence analysis was performed to yield sets of reference results of the transverse deflection at different time and spanwise position. We found good agreement between the computed natural frequencies at mode 1-3 and those obtained by previous theoretical study. Besides, modal separation analysis was carried out and the influence of mass ratio on deflection and natural frequencies was qualitatively and quantitatively assessed.

  16. Neural-net based calculation of voltage dips at maximum angular swing in direct transient stability analysis [of power systems

    Energy Technology Data Exchange (ETDEWEB)

    Djukanovic, M. (Inst. ' Nikola Tesla' , Belgrade (Yugoslavia)); Sobajic, D.J.; Yohhan Pao (Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Electrical Engineering and Applied Physics Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Computer Engineering and Science AI WARE inc., Cleveland, OH (United States))

    1992-10-01

    In heavily stressed power systems, post-fault transient voltage dips can lead to undesired tripping of industrial drives and large induction motors. The lowest transient voltage dips occur when fault clearing times are less than critical ones. In this paper, we propose a new iterative analytical methodology to obtain more accurate estimates of voltage dips at maximum angular swing in direct transient stability analysis. We also propose and demonstrate the possibility of storing the results of these computations in the associative memory (AM) system, which exhibits remarkable generalization capabilities. Feature-based models stored in the AM can be utilized for fast and accurate prediction of the location, duration and the amount of the worst voltage dips, thereby avoiding the need and cost for lengthy time-domain simulations. Numerical results obtained using the example of the New England power system are presented to illustrate our approach. (Author)

  17. Electrostatic clamp manufactured by novel method

    NARCIS (Netherlands)

    Sligte, E. te; Storm, A.; Koster, N.B.

    2011-01-01

    Electrostatic clamps (ESCs), used in reticle and wafer handling, are presently manufactured using glass bonding and polishing technologies. We present a patented alternative concept to this process, relying on coating and etching processes rather than bonding. We manufactured a first prototype clamp

  18. 21 CFR 870.4450 - Vascular clamp.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular clamp. 870.4450 Section 870.4450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4450 Vascular clamp. (a) Identification. A vascular...

  19. Time to implement delayed cord clamping.

    Science.gov (United States)

    McAdams, Ryan M

    2014-03-01

    Immediate umbilical cord clamping after delivery is routine in the United States despite little evidence to support this practice. Numerous trials in both term and preterm neonates have demonstrated the safety and benefit of delayed cord clamping. In premature neonates, delayed cord clamping has been shown to stabilize transitional circulation, lessening needs for inotropic medications and reducing blood transfusions, necrotizing enterocolitis, and intraventricular hemorrhage. In term neonates, delayed cord clamping has been associated with decreased iron-deficient anemia and increased iron stores with potential valuable effects that extend beyond the newborn period, including improvements in long-term neurodevelopment. The failure to more broadly implement delayed cord clamping in neonates ignores published benefits of increased placental blood transfusion at birth and may represent an unnecessary harm for vulnerable neonates.

  20. Thermal analysis of HTS air-core transformer used in voltage compensation type active SFCL

    Science.gov (United States)

    Song, M.; Tang, Y.; Li, J.; Zhou, Y.; Chen, L.; Ren, L.

    2010-11-01

    The three-phase voltage compensation type active superconducting fault current limiter (SFCL) is composed of three HTS air-core transformers and a three-phase four-wire Pulse Width Modulation (PWM) converter. The primary winding of the each phase HTS air-core transformer is in series with the main system, and the second winding is connected with the PWM converter. The single-phase conduction-cooled HTS air-core transformer is consisting of four double-pancakes wound by the Bi2223/Ag tape. In this paper, according to the electromagnetic analysis on the single-phase HTS air-core transformer, its AC loss corresponding to different operation modes is calculated. Furthermore, the thermal behaviors are studied by the time-stepping numerical simulations. On the basis of the simulation results, the related problems with the HTS air-core transformer's thermal stability are discussed.

  1. Modeling and Analysis of a Low-Voltage DC Distribution System

    Directory of Open Access Journals (Sweden)

    Joon Han

    2015-09-01

    Full Text Available It is well known that the Low-Voltage DC (LVDC distribution system is a promising topology as a future smart distribution system due to its high efficiency and reliability. However, there are still some challenges in the construction and implementation of an LVDC system. For practical application of the LVDC system, therefore, it is necessary to perform any simulation in advance by considering various conditions that can occur in an LVDC system. In order to provide a foundation for analyzing a DC system, this paper presents an LVDC distribution system model including essential components such as power electronic devices, Distributed Energy Resource (DER, and Energy Storage System (ESS, which can be considered for implementation in an LVDC system using Electro-Magnetic Transient Program (EMTP software. Moreover, an analysis of the characteristic in both the steady state and the transient state is conducted in an LVDC distribution system.

  2. Quantum Mechanical Analysis of GaN Nanowire Transistor for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Neel Chatterjee

    2016-12-01

    Full Text Available The paper presents the quantum mechanical analysis of Gallium Nitride nanowire transistor. The effect of high k gate dielectric and different gate metals on the electrical characteristics of the device is studied. Nanowire width has been reduced to have a proper control on the device characteristics at reduced gate length. A high value of drain current is obtained at gate length of 10 nm and nanowire radius equal to 10 nm, is obtained. Also high voltage operation of the device upto 40 volts has been shown. A flatter transconductance curve is obtained which shows the linearity of the device. The results obtained are comparable with the experimental and simulated data reported in literature

  3. Combat ready clamp medic technique.

    Science.gov (United States)

    Tovmassian, Robert V; Kragh, John F; Dubick, Michael A; Baer, David G; Blackbourne, Lorne H

    2012-01-01

    Junctional hemorrhage control device use on the battlefield might be lifesaving, but little experience is reported. The purpose of the present case report is to detail prehospital use of the Combat Ready Clamp (called the CRoC by its users, Combat Medical Systems, Fayetteville, NC; Instructions for Use, 2010) in casualty care in order to increase awareness of junctional hemorrhage control. The CRoC was used to control difficult inguinal bleeding on the battlefield for an Afghani man with a hindquarter traumatic amputation. The device promptly controlled exsanguination from a critical injury when placed during rotary-wing casualty evacuation. The flight medic applied the device in 90 seconds. The device performed well without complications to control bleeding. The CRoC, a new junctional hemorrhage control device, was used as indicated on the battlefield with mechanical and physiologic success and without device problems. By controlling difficult inguinal bleeding resulting from battlefield trauma, the device facilitated casualty stabilization and delivery to a surgical facility. The device facilitated the ability of a new flight medic to focus his expertise on a critically injured battlefield casualty with demonstrable success. 2012.

  4. Optimization of Temperature Coefficient and Noise Analysis of MOSFET- Only Voltage Reference Circuit

    Directory of Open Access Journals (Sweden)

    Arathi.p

    2016-09-01

    Full Text Available The optimization of temperature coefficient and comparison of output noise of two MOSFET only voltage references are introduced. The circuit behavior is analytically described and the performance of the proposed circuits are confirmed through 180nm CMOS technology in virtuoso and the simulation results are presented. Both the circuits can be operated with supply voltage varies from 0.5-1.2V.The output voltage references varied over a temperature range of -25℃ to 50℃.

  5. Three Level Diode Clamped Inverter Fed Induction Motor with Dtc-Svm

    Directory of Open Access Journals (Sweden)

    V. Ranjith Kumar

    2013-09-01

    Full Text Available This project presents a three-level diode-clamped inverter feeding an asynchronous motor drive with direct torque control (DTC. The control method is based on DTC operating principles. The stator voltage vector reference is computed from the stator flux and torque errors imposed by the flux and torque controllers. This voltage reference is then generated using a diode-clamped inverter, where each phase of the inverter can be implemented using a dc source, which would be available from fuel cells, batteries, or ultra capacitors. This inverter provides nearly sinusoidal voltages with very low distortion, even without filtering, using fewer switching devices. In addition, the multilevel inverter can generate a high and fixed switching frequency output voltage with fewer switching losses, since only the small power cells of the inverter operate at a high switching rate. Therefore, a high performance and also efficient torque and flux controllers are obtained, enabling a DTC solution for multilevel-inverter-powered motor drives. The Pulse Width modulation technique for an inverter permits to obtain three phase system voltages, which can be applied to the controlled output. Space Vector Modulation (SVPWM principle differs from other PWM processes in the fact that all three drive signals for the inverter will be created simultaneously. The implementation of SVPWM process in digital systems necessitates less operation time and also less program memory. This project uses SVPWM technique for generation of pulses for three-level diode clamped inverter. Simulation is carried out on MATLAB-Simulink software.

  6. Analysis of a dc SQUID readout scheme with voltage feedback circuit and low-noise preamplifier

    Science.gov (United States)

    Zeng, Jia; Zhang, Yi; Schmelz, Matthias; Mück, Michael; Krause, Hans-Joachim; Braginski, Alex I.; Lee, Yong-Ho; Stolz, Ronny; Kong, Xiangyan; Xie, Xiaoming; Meyer, Hans-Georg; Offenhäusser, Andreas; Jiang, Mianheng

    2014-08-01

    We analyzed the dc SQUID with voltage feedback circuit (VFC) and a low-noise room-temperature preamplifier to evaluate the feasibility of a low-noise SQUID direct-coupled readout scheme (DRS), possibly eliminating the need for a two-stage scheme employing a SQUID preamplifier. The passive VFC, connected in parallel to the SQUID, consists of a resistor Rs in series with an inductor L s. This inductor is coupled to the SQUID by a mutual inductance Ms. The purpose of the VFC is to increase the SQUID’s flux-to-voltage transfer coefficient ∂V/∂Φ, thus reducing the preamplifier noise contribution δΦpreamp. However, at the same time, VFC introduces the thermal noise of Rs, δΦR, which may not be negligible. Generally, the noise of the readout scheme, δΦreadout, may thus include both δΦpreamp and δΦR, i.e., δΦreadout2 = δΦpreamp2 + δΦR2. To characterize the SQUID operation with VFC we introduced two dimensionless parameters, r = Rs/Rd and Δ = (M s/Mdyn) - (Rs/R d), where Rd and Mdyn = 1/(∂i/∂Φ) are dynamic properties of the SQUID itself. For assumed intrinsic SQUID parameters, we then numerically analyzed the dependence of δΦreadout noise components on r and Δ to determine their suitable ranges and the minimum of δΦreadout. To verify our analysis, we experimentally characterized, in liquid helium, three niobium SQUIDs with VFC, having suitably chosen r and Δ. The measured SQUID system flux noise was on the order of 1 μΦ0/√Hz, comparable to the intrinsic noise of the SQUID itself. The deduced equivalent voltage noise was comparable to that of a SQUID preamplifier in the two-stage readout. Simple single-stage ultra-low-noise SQUID DRS readout was thus demonstrated.

  7. Field testing, modelling and analysis of ferroresonance in a high-voltage power system

    Science.gov (United States)

    Jacobson, David Allan Nils

    2000-11-01

    Catastrophic equipment failures continue to occur today due to ferroresonance even though this phenomenon has been extensively studied over the past ninety years. This thesis is concerned with the tasks of defining where ferroresonance problems can exist in a high voltage power system, of determining methods for displaying safety margins between nonferroresonant and ferroresonant operating regions and improving upon existing ferroresonance simulation techniques. Several different ferroresonant circuits have been modelled and compared with field measurements taken on the Manitoba Hydro 230-kV power system or compared with laboratory measurements including: a de-energized transformer connected to the grading capacitance of an open circuit breaker, a transformer-terminated doublecircuit transmission line and a coupling capacitor voltage transformer. In a high voltage power system, the most prevalent ferroresonance circuit occurs between a de-energized transformer and the grading capacitor of an open circuit breaker. Experimental work has shown that losses in a practical transformer are much larger during ferroresonance oscillation modes than predicted by conventional modelling techniques. A simple switched eddy-current loss resistor is found able to model the losses during subharmonic and fundamental frequency ferroresonance in a laboratory transformer. A major contribution of this work is a new method of visualizing the margin between nonferroresonant and ferroresonant states in a transformer/grading capacitor circuit has been developed. A general set of averaged equations is derived that permit the analysis of an nth order polynomial approximation of the magnetization curve. The location of the saddle points and slope of the stable manifold through the saddle points can be determined for a particular transformer under study. The Limacon of Pascal is found to be a good approximation to the geometric shape of the basin of attraction of the period-1 ferroresonant

  8. Evaluation of the strengthening of the conditions of voltage security using sensitivity analysis; Avaliacao do reforco das condicoes da seguranca de tensao utilizando a analise de sensibilidade

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, A.L.S.; Costa, V.M. da; Peres, W. [Universidade Federal de Juiz de Fora (UFJF), MG (Brazil). Faculdade de Engenharia], Emails: arleilucas@gmail.com, vander@lacee.ufjf.br, wesley.peres@yahoo.com.br; Prada, R.B. [Pontificia Universidade Catolica (PUC-Rio), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Eletrica], Email: prada@ele.puc-rio.br

    2009-07-01

    Voltage stability or voltage security analysis has motivated an expressive attention of power systems researchers. In this work, a simple and fast method evaluates voltage security and proposes conditions to improve the loading margin. System analysis is carried out in terms of active power transmission path. Sensitivity analysis provides the most adequate buses to active and reactive power redispatch. A sequential iterative methodology to reinforce system conditions is presented. (author)

  9. The Response Clamp: Functional characterization of neural systems using closed-loop control

    Directory of Open Access Journals (Sweden)

    Avner eWallach

    2013-01-01

    Full Text Available The voltage clamp method, pioneered by Hodgkin, Huxley and Katz, laid the foundations to neurophysiological research. Its core rationale is the use of closed-loop control as a tool for system characterization. A recently introduced method, the response clamp, extends the voltage clamp rationale to the functional, phenomenological level. The method consists of on-line estimation of a response variable of interest (e.g. the probability of response or its latency and a simple feedback control mechanism designed to tightly converge this variable towards a desired trajectory. In the present contribution I offer a perspective on this novel method and its applications in the broader context of system identification and characterization. First, I demonstrate how internal state variables are exposed using the method, and how the use of several controllers may allow for a detailed, multi-variable characterization of the system. Second, I discuss three different categories of applications of the method: (i exploration of intrinsically generated dynamics, (ii exploration of extrinsically generated dynamics and (iii generation of input-output trajectories. The relation of these categories to similar uses in the voltage clamp and other techniques is also discussed. Finally, I discuss the method’s limitations, as well as its possible synthesis with existing complementary approaches.

  10. Stokes polarimetry using analysis of the nonlinear voltage-retardance relationship for liquid-crystal variable retarders

    Energy Technology Data Exchange (ETDEWEB)

    López-Téllez, J. M., E-mail: jmlopez@comunidad.unam.mx; Bruce, N. C. [Centro de Ciencias Aplicadas y Desarrollo Tecnológico, Universidad Nacional Autónoma de México, Circuito Exterior S/N, Ciudad Universitaria, Apdo. Postal 70-186, México D.F., 04510 (Mexico)

    2014-03-15

    We present a method for using liquid-crystal variable retarders (LCVR’s) with continually varying voltage to measure the Stokes vector of a light beam. The LCVR's are usually employed with fixed retardance values due to the nonlinear voltage-retardance behavior that they show. The nonlinear voltage-retardance relationship is first measured and then a linear fit of the known retardance terms to the detected signal is performed. We use known waveplates (half-wave and quarter-wave) as devices to provide controlled polarization states to the Stokes polarimeter and we use the measured Stokes parameters as functions of the orientation of the axes of the waveplates as an indication of the quality of the polarimeter. Results are compared to a Fourier analysis method that does not take into account the nonlinear voltage-retardance relationship and also to a Fourier analysis method that uses experimental voltage values to give a linear retardance function with time. Also, we present results of simulations for comparison.

  11. Stokes polarimetry using analysis of the nonlinear voltage-retardance relationship for liquid-crystal variable retarders.

    Science.gov (United States)

    López-Téllez, J M; Bruce, N C

    2014-03-01

    We present a method for using liquid-crystal variable retarders (LCVR's) with continually varying voltage to measure the Stokes vector of a light beam. The LCVR's are usually employed with fixed retardance values due to the nonlinear voltage-retardance behavior that they show. The nonlinear voltage-retardance relationship is first measured and then a linear fit of the known retardance terms to the detected signal is performed. We use known waveplates (half-wave and quarter-wave) as devices to provide controlled polarization states to the Stokes polarimeter and we use the measured Stokes parameters as functions of the orientation of the axes of the waveplates as an indication of the quality of the polarimeter. Results are compared to a Fourier analysis method that does not take into account the nonlinear voltage-retardance relationship and also to a Fourier analysis method that uses experimental voltage values to give a linear retardance function with time. Also, we present results of simulations for comparison.

  12. THE ANALYSIS OF STEADY VOLTAGE ON THE ACCESSION OF DC TRACTION SUBSTATIONS

    Directory of Open Access Journals (Sweden)

    V. H. Sychenko

    2009-09-01

    Full Text Available Research results of voltage modes at traction substation buses in primary, regional and traction network are presented in the article. Numeric characteristics of probability density distributions are obtained. Autocorrelation functions of positive and negative sequence voltages are analyzed.

  13. Analysis of trigger behavior of high voltage LDMOS under TLP and VFTLP stress

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Jing; Qian Qinsong; Sun Weifeng; Liu Siyang, E-mail: zhj_seu@126.co [National ASIC System Engineering Research Center, Southeast University, Nanjing 210096 (China)

    2010-01-15

    The physical mechanisms triggering electrostatic discharge (ESD) in high voltage LDMOS power transistors (> 160 V) under transmission line pulsing (TLP) and very fast transmission line pulsing (VFTLP) stress are investigated by TCAD simulations using a set of macroscopic physical models related to previous studies implemented in Sentaurus Device. Under VFTLP stress, it is observed that the triggering voltage of the high voltage LDMOS obviously increases, which is a unique phenomenon compared with the low voltage ESD protection devices like NMOS and SCR. The relationship between the triggering voltage increase and the parasitic capacitances is also analyzed in detail. A compact equivalent circuit schematic is presented according to the investigated phenomena. An improved structure to alleviate this effect is also proposed and confirmed by the experiments. (semiconductor devices)

  14. The effect of reactive power generation modeling on voltage stability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tovar, E.; Guizar, J.G.C. [Inst. de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2010-08-13

    One of the most significant concerns for power system planning and operation in many countries involves problems related to voltage instability in electrical power systems. Blackouts have been caused by voltage instability problems throughout the world during the last few decades. Several factors can contribute to long term voltage instability problems, including high active and reactive loading, operation of on load tap changer transformers, inadequate locally available reactive power resources, load characteristics at low voltage magnitudes and operation of relay protection. There is a significant need to evaluate an index which gives the operating point proximity to voltage instability. This paper examined the influence of generator voltage dependent reactive power production on system voltage stability using the minimum singular value from the Jacobian Matrix of the load flow formulation. The synchronous generator model considered voltage reactive power limits due to maximum armature current, maximum and minimum field current as well as under excitation limiters. The generation model used in this paper was included in an ordinary load flow program, and resulted from studies of a representative 62 bus Norwest control area Mexican system, which included 19 generators. Specifically, the paper discussed the generator model with particular reference to the maximum field current limit; armature current limit; minimum field current limit; and underexcitation limit. The singular value decomposition and computational results were also presented. It was concluded that as the loading of the system increases, the reactive power produced by the machines also increases, and that reactive power is delivered when the induced voltage is greater than the terminal voltage. 15 refs., 3 tabs., 2 figs.

  15. Diagnosis of inverter switch open circuit faults based on neutral point voltage signal analysis

    Directory of Open Access Journals (Sweden)

    Liwei GUO

    Full Text Available Using the current signal to diagnose inverter faults information is apt to be affected by the load, noise and other factors; besides, it requires long diagnosis period with special algorithms and the diagnosis result is easily to be incorrect with no-load or light-load. Focusing on this issue, the logical analysis method is proposed for correlation logical analysis of leg neutral-point voltage and pulse signal to realize the diagnosis of the open circuit faults of inverter switches. The logical expressions of output signals of inverter power tube open-circuit faults is put forward and interrelated hardware circuit design is also elaborated. Delaying the rising edge of inverter power tube's pulse signal can effectively avoid the diagnosis error caused by the power tube's switching on/off. The experiment results show that the method can effectively diagnose the open-circuit faults of single-phase single power tube inverter in real-time and the hardware circuit cost is low, which shows it is effective and feasible.

  16. Dynamic clamp with StdpC software.

    Science.gov (United States)

    Kemenes, Ildikó; Marra, Vincenzo; Crossley, Michael; Samu, Dávid; Staras, Kevin; Kemenes, György; Nowotny, Thomas

    2011-03-01

    Dynamic clamp is a powerful method that allows the introduction of artificial electrical components into target cells to simulate ionic conductances and synaptic inputs. This method is based on a fast cycle of measuring the membrane potential of a cell, calculating the current of a desired simulated component using an appropriate model and injecting this current into the cell. Here we present a dynamic clamp protocol using free, fully integrated, open-source software (StdpC, for spike timing-dependent plasticity clamp). Use of this protocol does not require specialist hardware, costly commercial software, experience in real-time operating systems or a strong programming background. The software enables the configuration and operation of a wide range of complex and fully automated dynamic clamp experiments through an intuitive and powerful interface with a minimal initial lead time of a few hours. After initial configuration, experimental results can be generated within minutes of establishing cell recording.

  17. Molecular Mechanisms of DNA Polymerase Clamp Loaders

    Science.gov (United States)

    Kelch, Brian; Makino, Debora; Simonetta, Kyle; O'Donnell, Mike; Kuriyan, John

    Clamp loaders are ATP-driven multiprotein machines that couple ATP hydrolysis to the opening and closing of a circular protein ring around DNA. This ring-shaped clamp slides along DNA, and interacts with numerous proteins involved in DNA replication, DNA repair and cell cycle control. Recently determined structures of clamp loader complexes from prokaryotic and eukaryotic DNA polymerases have revealed exciting new details of how these complex AAA+ machines perform this essential clamp loading function. This review serves as background to John Kuriyan's lecture at the 2010 Erice School, and is not meant as a comprehensive review of the contributions of the many scientists who have advanced this field. These lecture notes are derived from recent reviews and research papers from our groups.

  18. Clamp force and alignment checking device

    Energy Technology Data Exchange (ETDEWEB)

    Spicer, John Patrick; Cai, Wayne W.; Chakraborty, Debejyo; Mink, Keith

    2017-04-11

    A check fixture measures a total clamp force applied by a welder device. The welder device includes a welding horn having a plurality of weld pads and welding anvil having a plurality of weld pads. The check fixture includes a base member operatively supporting a plurality of force sensors. The base member and the force sensors are received between the weld pads of the welding horn and the anvil pads of the welding anvil. Each force sensor is configured to measure an individual clamp force applied thereto by corresponding weld and anvil pads when the base member is received between the welding horn and the welding anvil and the welder device is in the clamped position. The individual clamp forces are used to determine whether the weld and/or anvil pads are worn or misaligned.

  19. Program for analysis of permanent status and voltage stability; Programa para analisis de estado permanente y estabilidad de tension

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Krekeler, Ubaldo [Administracion Nacional de Electricidad (ANDE), Asuncion (Paraguay)]. E-mail: ufernandez@ieee.org; Cardozo Sanchez, Freddy [Mirant Americas (United States)

    2001-07-01

    In this work is presented a computational tool to evaluate voltage stability based on statistical analysis techniques. This tool was developed in MATLAB and implements routines through which the Q-V y P-V curves can be obtained, as well as the system self-values in relation to a determined operation point.

  20. Blood gas values in clamped and unclamped umbilical cord at birth.

    Science.gov (United States)

    Di Tommaso, Mariarosaria; Seravalli, Viola; Martini, Irene; La Torre, Pasquale; Dani, Carlo

    2014-09-01

    To determine the reliability of the cord blood gas analysis on the unclamped cord compared to the standard technique of sampling on double clamped cord. Prospective observational study conducted on 46 singleton neonates vaginally delivered at term. Matched pairs of umbilical artery and vein blood samples were collected from unclamped cord within 90s after birth and from the same cord after clamping, with the clamping occurring immediately after the first blood collection. A blood gas analysis was performed on each collected sample. Arterial and venous blood samples were analyzed for pH, PO2, pCO2, SaO2, hemoglobin concentration (ctHb) and base excess (BE). The values were compared between the two groups (clamped vs unclamped) using a Wilcoxon test. No significant difference was found in pH, PO2, pCO2, SaO2 and ctHb values on arterial blood between unclamped and clamped cord. The only significant difference was related to BE (pblood, the values of pH, PO2, pCO2 were comparable between unclamped and clamped cord, while the values of SaO2, ctHb and BE were significantly different (pblood gas parameters and in the main venous blood gas parameters between unclamped and clamped cord. Sampling of cord blood for gas analysis may be performed on the unclamped cord right after birth without reducing the accuracy of the analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata

    Science.gov (United States)

    Som, Sumit; Seth, Sudeshna; Mandal, Aditya; Paul, Saikat; Duttagupta, Anjan

    2013-02-01

    Variable Energy Cyclotron Centre has commissioned a K-500 superconducting cyclotron for various types of nuclear physics experiments. The 3-phase radio-frequency system of superconducting cyclotron has been developed in the frequency range 9-27 MHz with amplitude and phase stability of 100 ppm and ±0.20, respectively. The analysis of the RF cavity has been carried out using 3D Computer Simulation Technology (CST) Microwave Studio code and various RF parameters and accelerating voltages ("Dee" voltage) are calculated from simulation. During the RF system commissioning, measurement of different RF parameters has been done and absolute Dee voltage has been calibrated using a CdTe X-ray detector along with its accessories and known X-ray source. The present paper discusses about the measured data and the simulation result.

  2. Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

    DEFF Research Database (Denmark)

    Vasquez, Juan Carlos; Guerrero, Josep M.; Savaghebi, Mehdi

    2011-01-01

    and discussed. Experimental results are provided to validate the performance and robustness of the VSIs functionality during Islanded and grid-connected operations, allowing a seamless transition between these modes through control hierarchies by regulating frequency and voltage, main-grid interactivity......Power electronics based microgrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of three-phase VSIs are derived. The proposed voltage and current inner control loops and the mathematical models...... the frequency and amplitude deviations produced by the primary control. And the tertiary control regulates the power flow between the grid and the microgrid. Also, a synchronization algorithm is presented in order to connect the microgrid to the grid. The evaluation of the hierarchical control is presented...

  3. Analysis of temporal and spatial contact voltage fluctuation during fretting in automotive connectors

    OpenAIRE

    El Mossouess, Sofiane; Benjemâa, N; Carvou, E; El Abdi, R; Obame, H; Doublet, L; Rodari, T

    2014-01-01

    International audience; Our study is focused on contact voltage fluctuations during fretting with small amplitudes of a few tens microns which generate damage of the contact of connectors. A contact composed by a pin and a curve female part are submitted to vibration cyclic of 25µm at 100Hz and supplied with current ramp from 0.1mA to 3A in two directions. With the help of fast devices, the voltage and position data acquisition are conjointly made with the common DC contact voltage dur-ing fr...

  4. Ergonomic redesign and evaluation of a clamping tool handle.

    Science.gov (United States)

    Jung, Myung-Chul; Hallbeck, M Susan

    2005-09-01

    The handle of a commercial bar clamp was redesigned using ergonomic principles and then compared with an original clamp. Ten male and ten female students participated in simulated clamping tasks under various conditions, including different clamping heights, clamping methods, and handle-gripping methods, with respect to the dependent variables of clamping and handle-squeezing forces. The results showed that the redesigned clamp produced larger clamping force with lower handle-squeezing forces than the original clamp. As expected, males exerted more force than females in both clamping and squeezing forces. A pistol grip method was superior to an upside-down handle-gripping method. Two-handed operation was recommended for this type of clamp by simultaneously pulling the trigger and sliding the bar in order to initially tighten around objects. This study shows that the application of ergonomic guidelines increases the efficiency and usability of manual handtools.

  5. High-Efficiency Isolated Boost DCDC Converter for High-Power Low-Voltage Fuel-Cell Applications

    DEFF Research Database (Denmark)

    Nymand, Morten; Andersen, Michael A. E.

    2010-01-01

    A new design approach achieving very high conversion efficiency in low-voltage high-power isolated boost dc-dc converters is presented. The transformer eddy-current and proximity effects are analyzed, demonstrating that an extensive interleaving of primary and secondary windings is needed to avoid...... high winding losses. The analysis of transformer leakage inductance reveals that extremely low leakage inductance can be achieved, allowing stored energy to be dissipated. Power MOSFETs fully rated for repetitive avalanches allow primary-side voltage clamp circuits to be eliminated. The oversizing...

  6. Analysis of crowbar action of high voltage DC power supply in the LHD ICRF system

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiaodong [Southwestern Institute of Physics, Chengdu, Sichuan (China); Mutoh, T.; Kumazawa, R.; Watari, T.; Seki, T.; Shimpo, F.; Nomura, G.; Saito, K.

    1999-04-01

    Ion Cyclotron Range of Frequency (ICRF) heating will be applied to the Large Helical Device (LHD) at the 2nd experimental campaign in 1998. The LHD ICRF system is characterised by its high power (up to 12 MW at final stage) and steady state operation for more than 30 minutes. One of the main R and D items was a high power and steady state transmitter. The RF transmitter system having a wide frequency range from 25 to 95 MHz was designed and fabricated. This report describes the analysis of the DC power supply that contains the crowbar circuit protecting the tetrode from the arcing inside the tube. The DC power supply of the transmitter is fed from the commercial AC electric line which also supply the power to the LHD helical and poloidal coil power supplies. The voltage drop of the commercial line when the ICRF crowbar action happened is the serious problem for all experimental system. This paper analyses the crowbar effect on the commercial line with and without leakage transformer between the step-up transformer of transmitter and the commercial line. (author)

  7. Laser ultrasonic analysis of normal modes generated by a voltage pulse on an AT quartz sensor.

    Science.gov (United States)

    Goossens, Jozefien; Martinez, Loïc; Glorieux, Christ; Wilkie-Chancellier, Nicolas; Ehssein, Chighali Ould; Serfaty, Stéphane

    2006-12-22

    Laser ultrasonic detection is a versatile and highly sensitive tool for the observation of surface waves. In the following study, laser ultrasonic detection is used for the experimental study of spurious normal vibration modes of a disk quartz sensor excited by a voltage pulse. The AT cut crystal (cut of the crystal relative to the the main crystallographic axis is 35.25 degrees) is optimal for generating mainly thickness-shear vibrations (central frequency 6 MHz) on the quartz surface. However, resulting from shear-to-longitudinal and shear-to-surface mode conversion, and from the weak coupling with the other crystallographic axes, other modes (thickness-compressional and bending modes) are always present in the plate response. Since the laser vibrometer is sensitive to normal displacements, the laser investigation shows waves that can be considered as unwanted for the AT quartz used as a shear sensor. The scanned three dimensional (3D) amplitude-space-time signals are carefully analysed using their representation in three dual Fourier domains (space-time, wave number-frequency). Results on the transient analysis of the waves, the normal bending modes and the dispersion curves are shown.

  8. THEORETICAL ANALYSIS OF CHARGE ACCUMULATION ON INSULATOR SURFACE UNDER IMPULSE VOLTAGE IN A GAS INSULATED SWITCHGEAR

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective To investigate the process and mechanism of insulator surface charge accumulation under impulse voltage, a dynamic equation was established for describing the relationship between surface charge density and applied voltage. Results The established equation is more generalized in comparison with that given by other previous investigators. Constants A, B for typical electrodes used in the present equation are specified. The process and mechanism of surface charge accumulation under impulse voltage are studied and the factors that influence surface charge accumulation discussed. Conclusion The present theoretical studies help to explain why surface charging can be accomplished instantly under impulse voltage, and determine the factors influencing surface charge accumulation. The findings confirmed some surface charging phenomena observed in GIS by some previous investigators.

  9. Analysis of predictor factors of limb amputation in patients with high-voltage electrical burns

    OpenAIRE

    2015-01-01

    Background: Limb amputation is considered one of the most devastating consequences of electrical injury. Any factors that correlate with the degree of muscle damage can be used to predict the necessity of limb amputation. The aim of this study was to determine the factors that can be used to predict limb amputation in high-voltage electrically injured patients. Methods: Eighty-two high-voltage electrically injured patients were admitted to the Department of Plastic and Reconstructive Surg...

  10. Performance Analysis of Phase Controlled Unidirectional and Bidirectional AC Voltage Controllers

    Directory of Open Access Journals (Sweden)

    Abdul Sattar Larik

    2011-01-01

    Full Text Available AC voltage controllers are used to vary the output ac voltage from a fixed ac input source. They are also commonly called ac voltage regulators or ac choppers. The output voltage is either controlled by PAC (Phase Angle Control method or on-off control method. Due to various advantages of ac voltage controllers, such as high efficiency, simplicity, low cost and ability to control large amount of power they efficiently control the speed of ac motors, light dimming and industrial heating, etc. These converters are variable structure systems and generate harmonics during the operation which will affect the power quality when connected to system network. During the last couple of years, a number of new semiconductor devices and various power electronic converters has been introduced. Accordingly the subject of harmonics and its problems are of great concern to power industry and customers. In this research work, initially the simulation models of single phase unidirectional and bidirectional ac voltage controllers were developed by using MATLAB software. The harmonics of these models are investigated by simulation. In the end, the harmonics were also analyzed experimentally. The simulated as well as experimental results are presented.

  11. Indentation metrology of clamped, ultra-thin elastic sheets

    OpenAIRE

    Vella, Dominic; Davidovitch, Benny

    2017-01-01

    We study the indentation of ultrathin elastic sheets clamped to the edge of a circular hole. This classical setup has received considerable attention lately, being used by various experimental groups as a probe to measure the surface properties and stretching modulus of thin solid films. Despite the apparent simplicity of this method, the geometric nonlinearity inherent in the mechanical response of thin solid objects renders the analysis of the resulting data a nontrivial task. Importantly, ...

  12. Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

    DEFF Research Database (Denmark)

    Vasquez, Juan Carlos; Guerrero, Josep M.; Savaghebi, Mehdi;

    2013-01-01

    Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops and the mat......Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops...... and the mathematical models of the VSIs are based on the stationary reference frame. A hierarchical control scheme for the paralleled VSI system is developed comprising two levels. The primary control includes the droop method and the virtual impedance loops, in order to share active and reactive power. The secondary...... control restores the frequency and amplitude deviations produced by the primary control. Also, a synchronization algorithm is presented in order to connect the MicroGrid to the grid. Experimental results are provided to validate the performance and robustness of the parallel VSI system control...

  13. Analysis of Voltage Transfer Characteristics of Nano-scale SOI CMOS Inverter with Variable Channel Length and Doping Concentration

    Directory of Open Access Journals (Sweden)

    A. Daniyel Raj

    2015-03-01

    Full Text Available During many decades, continuous device performance improvement has been made possible only through device scaling. But presently, due to aggressive scaling at the sub-micron or nanometer region, the conventional planner silicon technology is suffering from the fundamental physical limits. Such imposed limits on further downscaling of silicon planner technology have lead to alternative device technology like Silicon-On-Insulator (SOI technology. Due-to some of its inherent advantages, the Silicon-On-Insulator (SOI technology has reduced the Short-channel-effects (SCEs and thus increased transistor scalability. Till now, intense research interests have been paid in practical fabrication and theoretical modeling of SOI MOSFETs but a little attention has been paid to understand the circuit level performance improvement with nano-scale SOI MOSFETs. The circuit level performance analysis of SOI MOSFET is highly essential to understand the impact of SOI technology on next level VLSI circuit and chip design and for doing so device compact models are high on demand. In such scenario, under present research, a physics based compact device model of SOI MOSFET has been developed. At the first phase of the compact model development, a physics based threshold voltage model has been developed by solving 2-D Poisson’s equation at the channel region and at the second phase, a current-voltage model has been developed with drift-diffusion analysis. Different SCEs, valid at nano-scale, are effectively incorporated in threshold voltage and Current-Voltage model. At the third phase, using the compact model, the Voltage Transfer Characteristics (VTC for a nano-scale SOI CMOS inverter has been derived with graphical analysis. The impacts of different device parameters e.g.; channel length and channel doping concentration on VTC has been investigated through simulation and the results have been analyzed.

  14. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.;

    2012-01-01

    Transformer based Z-source (trans-Z-source) inverters are recently proposed by extending the traditional Z-source inverter with higher buck-boost capability as well as reducing the passive components at the same time. Multi-Level Z-source inverters are single-stage topological solutions used...... modulation scheme, the three-level trans-Z-source inverter can function with minimum of six device commutations per half carrier cycle (same as the traditional buck NPC inverter), while maintaining to produce the designed volt-sec average and inductive voltage boosting at ac output terminals. The designed...... for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...

  15. A Modal Analysis Study of Thin Parallelogram Plates Clamped on the Rim with and without Defects Using the SolidWorks Program

    Directory of Open Access Journals (Sweden)

    Marian-Dumitru Nedeloni

    2015-09-01

    Full Text Available This paper presents the study of the modal analysis of four types of plates in parallelogram shape, with or without defects, using the SolidWorks program. The results obtained after this study, have targeted the behavior of plates regarding the mesh, the deformation scale, the resultant amplitude, the rotational speeds, respectively the Eigen frequencies according to the vibration modes.

  16. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H. R.; Pol, Robert A.; Hulsebos, Robin G.; van Det, Rob J.; van der Palen, Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    BACKGROUND: To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. METHODS: Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inl

  17. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H.R.; Pol, Robert A.; Hulsebos, Robin G.; Det, van Rob J.; Palen, van der Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    Background To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. Methods Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inla

  18. Vascular clamping in liver surgery: physiology, indications and techniques

    Directory of Open Access Journals (Sweden)

    Cherqui Daniel

    2010-03-01

    Full Text Available Abstract This article reviews the historical evolution of hepatic vascular clamping and their indications. The anatomic basis for partial and complete vascular clamping will be discussed, as will the rationales of continuous and intermittent vascular clamping. Specific techniques discussed and described include inflow clamping (Pringle maneuver, extra-hepatic selective clamping and intraglissonian clamping and outflow clamping (total vascular exclusion, hepatic vascular exclusion with preservation of caval flow. The fundamental role of a low Central Venous Pressure during open and laparoscopic hepatectomy is described, as is the difference in their intra-operative measurements. The biological basis for ischemic preconditioning will be elucidated. Although the potential dangers of vascular clamping and the development of modern coagulation devices question the need for systemic clamping; the pre-operative factors and unforseen intra-operative events that mandate the use of hepatic vascular clamping will be highlighted.

  19. Analysis of voltage unbalance effects on induction motors with open and closed slots

    Energy Technology Data Exchange (ETDEWEB)

    Donolo, Pablo, E-mail: pdonolo@gmail.co [Grupo de Electronica Aplicada, Fac. de Ingenieria, Universidad Nacional de Rio Cuarto, Ruta Nac. 36 Km 601 (X5804BYA), Rio Cuarto, Cordoba (Argentina); Bossio, Guillermo, E-mail: gbossio@ieee.or [Grupo de Electronica Aplicada, Fac. de Ingenieria, Universidad Nacional de Rio Cuarto, Ruta Nac. 36 Km 601 (X5804BYA), Rio Cuarto, Cordoba (Argentina); De Angelo, Cristian, E-mail: cdeangelo@ieee.or [Grupo de Electronica Aplicada, Fac. de Ingenieria, Universidad Nacional de Rio Cuarto, Ruta Nac. 36 Km 601 (X5804BYA), Rio Cuarto, Cordoba (Argentina)

    2011-05-15

    Research highlights: {yields} We study the increase of losses in the induction motor (IM) with voltage unbalance. {yields} We take into account the variations in the negative-sequence impedance of the rotor. {yields} We analyze the performance in IM with open and closed rotor slots. {yields} For both type of rotors, we get the derating factor for different levels of unbalance. {yields} IM with closed-slot are less affected by voltage unbalance than open-slot ones. -- Abstract: This paper aims to complement studies concerning the influence of voltage unbalance on the performance of induction motors. We use sequence equivalent circuits to determine the increase of losses in the induction motor. We take into account the dependence of the rotor negative-sequence reactance with the load state and the increase in rotor resistance with the negative-sequence currents. Variations in the negative-sequence impedance are related with the structural characteristics of the rotor. We analyze motors with open and closed rotor slots, because the impedance of rotors with closed slots grows considerably when the load is less than rated, producing lower negative-sequence currents and lower losses. Increased rotor impedance in closed slot motors protects these motors against problems due to unbalanced supply voltage. For both type of rotors, we analyze motor derating factor based on voltage unbalance and increases in total losses and rotor losses.

  20. A novel neutral point voltage control strategy of three-level NPC converter and its single switch cycle control region analysis%新型三电平变流器中点电压控制策略及其可控区域

    Institute of Scientific and Technical Information of China (English)

    李宁; 王跃; 蒋应伟; 王兆安

    2015-01-01

    针对三电平中点钳位( neutral point clamped, NPC)变流器中点电压波动问题,分析了三电平变流器基本工作原理,提出了一种适用于任意调制策略的三电平变流器中点电压平衡策略。该策略以输出线电压满足要求为控制目标,根据中点电压的波动情况实时修正调制策略的输出开关状态。鉴于单开关周期完全可控区域的重要意义,本文分别分析了调制策略为正弦脉宽调制( si-nusoidal pulse width modulation,SPWM)策略和空间矢量脉宽调制( space vector pulse width modula-tion,SVPWM)策略时新型中点电压平衡策略的单开关周期完全可控区域。理论分析和仿真结果表明,新型中点电压平衡策略具有普遍适用、实现简单的优点,其单开关周期完全可控区域受调制策略、调制度、运行时间和功率因数的影响。%A novel neutral point ( NP ) voltage control strategy of three - level neutral point clamped ( NPC) converter was proposed to eliminate the NP voltage fluctuation under any modulation strategy. The novel NP voltage control strategy was based on the control target of output line voltage, and real-time correction of output switching states were given according to the NP voltage fluctuation. It is suitable for any modulation strategy as it only deals with the output switching states of any modulation strategy. In order to analyze the control effect of the proposed strategy, the single switch cycle control region was taken as the measurement standard and analysis of fully control region was conducted respectively when using the two most commonly used modulation strategy, sinusoidal pulse width modulation ( SPWM) strategy and space vector pulse width modulation ( SVPWM) . The theoretical analysis and simulation results show that the novel NP voltage control strategy has the advantages of wide application and easy implementation. Whereas, the fully control region of the new strategy is affected by

  1. Functional dissection of synaptic circuits: in vivo patch-clamp recording in neuroscience

    Directory of Open Access Journals (Sweden)

    Can eTao

    2015-05-01

    Full Text Available Neuronal activity is dominated by synaptic inputs from excitatory or inhibitory neural circuits. With the development of in vivo patch-clamp recording, especially in vivo voltage-clamp recording, researchers can not only directly measure neuronal activity, such as spiking responses or membrane potential dynamics, but also quantify synaptic inputs from excitatory and inhibitory circuits in living animals. This approach enables researchers to directly unravel different synaptic components and to understand their underlying roles in particular brain functions. Combining in vivo patch-clamp recording with other techniques, such as two-photon imaging or optogenetics, can provide even clearer functional dissection of the synaptic contributions of different neurons or nuclei. Here, we summarized current applications and recent research progress using the in vivo patch-clamp recording method and focused on its role in the functional dissection of different synaptic inputs. The key factors of a successful in vivo patch-clamp experiment and possible solutions based on references and our experiences were also discussed.

  2. A New Control Method of a Resonant Switched-Capacitor Converter and the Application for Balancing of the Split DC Voltages in a Multilevel Inverter

    Science.gov (United States)

    Sano, Kenichiro; Fujita, Hideaki

    This paper proposes a new voltage-balancing circuit for the split dc voltages in a diode-clamped five-level inverter. The proposed circuit is based on a resonant switched-capacitor converter (RSCC), which consists of two half-bridge inverters, a resonant inductor and a resonant capacitor. A new phase-shift control of the RSCC is proposed to improve voltage balancing performance. Theoretical analysis reveals the rating of the RSCC and stored energy in the resonant inductor. Experimental results confirm the reduction of the inductor to one tenth in volume as compared to a conventional voltage-balancing circuit based on buck-boost topology. Moreover, the proposed phase-shift control has demonstrated that it is possible to eliminate the voltage deviation between the dc capacitors.

  3. Compact, Stiff, Remotely-Actuable Quick-Release Clamp

    Science.gov (United States)

    Tsai, Ted W. (Inventor)

    2000-01-01

    The present invention provides a clamp that is compact and lightweight, yet provides high holding strength and stiffness or rigidity. The clamp uses a unique double slant interface design which provides mechanical advantages to resist forces applied to the clamp member as the load increases. The clamp allows for rapid and remote-activated release of the clamp jaws by applying only a small operating force to an over-center lock/release mechanism, such as by pulling a manual tether.

  4. Design and application of multifunctional stomach clamp

    Institute of Scientific and Technical Information of China (English)

    Yun Fu Lu; Pi Wu Li; Xir Xin Zhang

    2000-01-01

    AIM Pylorus and pyloric vagus preserving gastrectomy (PPVPG) is an efficient operation mode for treatinggastric and duodenal ulcers. For its better application and popularization, we have designed andmanufactured a special multifunctional stomach clamp.METHODS The clamp has been designed carefully in view of the different sizes of the patients' stomachsand the different starting points of Latarjer nerves so as to facilitate the execution of the present operationmode, which requires the preservation of the vagus innervated pyloric region so as to make the remnantstomach maintain its normal physiological function and the vagus branches clinging antral seromuscular flapkept in proper size so that avoiding too much remaining antral mucosa is removed to cause greater difficultyin operation. With this in view, we observed and measured the distance between the Latarjer nerves distribution and the pyloric rings of 42 patients' stomachs in the course of operations. We bent an aluminumstring 3 mm thick for each stomach according to the size of antral seromuecular flap and chose an optimalcurvature from the 42 sizes for manufacturing the clamp. The clamp is made of 3 Cr13 stainless steel,consisting of three parts, the curved head, the fastening ring and the handle. The curved head is shapedalmost exactly like the remained antral seromuscular flap. The ring at its tip when in place fastens the twosides of the clamp so that the tissue of the stomach between will be clutched by an even force. On one sideare three cuts for moving the ring upwards, each cut representing 1 mm for fastening and adjustments can bemade in view of the thickness or thinness of the tissue. The handles bend backward for fighting shy of thecuts so as to facilitate the operation.RESULTS With the stomach disassociated in the light of PPVPG procedures, the clamp may easily beapplied from the upper part of the Latarjer nerves. The following merits can be noted. ① The curving line ofthe flap can be precisely

  5. Analysis and calculation of lightning-induced voltages in aircraft electrical circuits

    Science.gov (United States)

    Plumer, J. A.

    1974-01-01

    Techniques to calculate the transfer functions relating lightning-induced voltages in aircraft electrical circuits to aircraft physical characteristics and lightning current parameters are discussed. The analytical work was carried out concurrently with an experimental program of measurements of lightning-induced voltages in the electrical circuits of an F89-J aircraft. A computer program, ETCAL, developed earlier to calculate resistive and inductive transfer functions is refined to account for skin effect, providing results more valid over a wider range of lightning waveshapes than formerly possible. A computer program, WING, is derived to calculate the resistive and inductive transfer functions between a basic aircraft wing and a circuit conductor inside it. Good agreement is obtained between transfer inductances calculated by WING and those reduced from measured data by ETCAL. This computer program shows promise of expansion to permit eventual calculation of potential lightning-induced voltages in electrical circuits of complete aircraft in the design stage.

  6. Analysis of a Microgrid under Transient Conditions Using Voltage and Frequency Controller

    Directory of Open Access Journals (Sweden)

    Monika Jain

    2012-01-01

    Full Text Available This paper presents an investigation of voltage-and-frequency-(VF- based battery energy storage system (BESS controller used in micro grid for analyzing the optimum capability of plant. Microgrid is formed by using three hydropower plants feeding three-phase four-wire load. The proposed controller is used for load balancing, harmonic elimination, load leveling, and neutral current compensation. The proposed BESS controller permits the selection of an optimum voltage level of battery and allows independent current control of each phase. The main emphasis is given on maintaining constant voltage and frequency within the micro grid during transient conditions. Micro grid with power plant and its controller is modeled in MATLAB/Simulink using Power System Blockset (PSB toolboxes.

  7. Water dissociation phenomena in a bipolar membrane——The configurations and theoretical voltage analysis

    Institute of Scientific and Technical Information of China (English)

    徐铜文; 杨伟华; 何炳林

    1999-01-01

    The models were established for the theoretical current-voltage characteristics in water dissociation process on a bipolar membrane. Particular attention was given to the transport of the water ions and electrolyte ions as well as the membrane physical structure and configuration. The factors on the water splitting process were adequately analysed based on the derived theoretical current-voltage characteristics and several good suggestions were proposed for decreasing the work voltage in practical operations. In addition, the model can give a reasonable explanation for the catalytic effect of some chemicals, such as amphiprotic hydroxide compounds, weak polymeric acids and bases, etc. It is shown that the catalyst may be responsible for the increase in dissociation rate constant of water and therefore enhance the water dissociation. The guidelines for choosing a proper catalyst were also proposed.

  8. Characteristic Analysis of Partial Discharges and Dissolved Gases Generated Cavityin Oil-paper Insulation Under AC-DC Combined Voltages

    Institute of Scientific and Technical Information of China (English)

    HE Zhiman; LI Jian; BAO Lianwei; JIANG Tianyan; WANG Youyuan

    2012-01-01

    Oil-paper insulation is used within most of high voltage direct current(HVDC) converter transformers.Partial discharge(PD) in oil-paper insulation is a major reason for the development of internal faults in HVDC converter transformer,while PDs in oil-paper insulation mainly occur in terms of gas cavity discharges.There are few study results on the development characteristics of partial discharges in oil-paper insulation and dissolved gases in oils of HVDC converter transformers.Based on a gas cavity discharge model of oil-paper insulation,the present study investigates the development characteristics of partial discharges under AC-DC combined voltages and emphatically examines the variation characteristics of dissolved gases in the discharge development process.Experiment and analysis results show that the characteristics of partial discharges and dissolved gases in oils under AC-DC combined voltages are appreciably different with those under AC voltage.These results provide theoretical support for further research on partial discharges and on dissolved gases of other internal insulating defects and are helpful for the fault diagnosis of HVDC converter transformers.

  9. 16nm planar process CMOS SRAM cell design: Analysis of Operating Voltage and Temperature Effect

    Directory of Open Access Journals (Sweden)

    Rohit Sharma

    2013-09-01

    Full Text Available Purpose: CMOS devices are scaling down to nano ranges resulting in increased process variations and short channel effects which not only affect the reliability of the device but also performance expectations. The SRAM design uses the smallest transistors possible and is also susceptible to reliability issues and process variations, making it an ideal benchmark circuit to compare the two technologies [1]. Low power static-random access memories (SRAM have become a critical component in modern VLSI systems. They occupy a large portion of area and accounts for a major component of power consumption in today’s VLSI circuits. In this paper we intend to analyse the performance of a traditional 6T SRAM cell of 16nm Complementary Metal Oxide Semiconductor (CMOS technology with change in Operating Voltage and Temperature. Aim: The aim of the paper is to study the effect of the SNM dependencies on the operating voltage and temperatureApproach: Conventional 6T SRAM are designed using predictive technology model developed by Arizona State University [2] of 16nm planar Low Power CMOS and variation of SNM with operating voltage and temperature are simulated and studied using hspice.Findings: Variations in the operating voltages and temperature strongly impact the stability of an SRAM cell at 16nm. Comparative study is done for predictive 16nm based conventional 6T SRAM cell by varying operating voltage and temperature. A methodology to select operating voltage is suggested which can be used in an early stage of a design cycle to optimise stability margins in nanometer regime

  10. ANALYSIS OF GRID-CONNECTED PHOTOVOLTAIC SYSTEM INTEGRATON ON LOW-VOLTAGE DISTRIBUTION NETWORK

    Directory of Open Access Journals (Sweden)

    NEMES C.

    2016-03-01

    Full Text Available The introduction of new local sources on the distribution network will impact the quality of power in different ways. The low-voltage customers are strongly affected by the level of power quality, especially by harmonic distortions. In present paper, the impact on the power quality of a low-voltage utility network with an integrated PV system has been assessed at the point of common coupling of the PV system. In this order, the most representative power quality indices concerning the harmonic distortion have been monitored and compared with the limits set by the corresponding standards.

  11. Analysis of Mechanical Stresses Due to Voltage Dips in Fixed-Speed Wind Turbines

    DEFF Research Database (Denmark)

    Veluri, Badrinath; Santos-Martin, David; Jensen, Henrik Myhre

    2011-01-01

    drivetrain components. An electro-mechanical model is built to simulate the grid disturbances that easily excite the asynchronous generator poorly damped stator flux oscillations, which cause high transients of the generator electromagnetic torque. This article focuses in estimating the resulting significant...... stresses transients that may have a detrimental effect on the fatigue life of drivetrain system due to voltage dips. A rainflow cycle counting method for the stress history during the voltage dip event, analyses mean and amplitudes of the counted cycles, their occurrence moment and time of duration....

  12. Modeling and Stress Analysis of Doubly-Fed Induction Generator during Grid Voltage Swell

    DEFF Research Database (Denmark)

    Zhou, Dao; Song, Yipeng; Blaabjerg, Frede

    2016-01-01

    The Doubly-Fed Induction Generator (DFIG) based wind turbine system is presently dominant in the wind turbine market. Due to heavy load switch-off and faults in the power grid, voltage swells may occur and this phenomenon is currently given sufficient insights. This paper starts to describe...... the transient voltage swell and its recovery. It is concluded that although both higher swell level and higher rotor speed cause higher rotor electromotive force, the doubly-fed induction generator can successfully ride through the grid fault due to the relatively small swell level required by the modern grid...

  13. Harmonics and voltage stability analysis in power systems including thyristor-controlled reactor

    Indian Academy of Sciences (India)

    M Uzunoglu

    2005-02-01

    In this study, non-sinusoidal quantities and voltage stability, both known as power quality criteria, are examined together in detail. The widespread use of power electronics elements cause the existence of significant non-sinusoidal quantities in the system. These non-sinusoidal quantities can create serious harmonic distortions in transmission and distribution systems. In this paper, harmonic generation of a static VAR compensator with thyristor-controlled reactor and effects of the harmonics on steady-state voltage stability are examined for various operational conditions.

  14. A complete dc characterization of a constant-frequency, clamped-mode, series-resonant converter

    Science.gov (United States)

    Tsai, Fu-Sheng; Lee, Fred C.

    1988-01-01

    The dc behavior of a clamped-mode series-resonant converter is characterized systematically. Given a circuit operating condition, the converter's mode of operation is determined and various circuit parameters are calculated, such as average inductor current (load current), rms inductor current, peak capacitor voltage, rms switch currents, average diode currents, switch turn-on currents, and switch turn-off currents. Regions of operation are defined, and various circuit characteristics are derived to facilitate the converter design.

  15. Battery open-circuit voltage estimation by a method of statistical analysis

    NARCIS (Netherlands)

    Snihir, Iryna; Rey, William; Verbitskiy, Evgeny; Belfadhel-Ayeb, Afifa; Notten, Peter H.L.

    2006-01-01

    The basic task of a battery management system (BMS) is the optimal utilization of the stored energy and minimization of degradation effects. It is critical for a BMS that the state-of-charge (SoC) be accurately determined. Open-circuit voltage (OCV) is directly related to the state-of-charge of the

  16. Analysis of the Interphase on Carbon Black Formed in High Voltage Batteries

    DEFF Research Database (Denmark)

    Younesi, Reza; Christiansen, Ane Sælland; Scipioni, Roberto

    2015-01-01

    Carbon black (CB) additives commonly used to increase the electrical conductivity of electrodes in Li-ion batteries are generally believed to be electrochemically inert additives in cathodes. Decomposition of electrolyte in the surface region of CB in Li-ion cells at high voltages up to 4.9 V...

  17. Grid modeling, analysis and simulation of different scenarios for a smart low-voltage distribution grid

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Han, Xue; Bindner, Henrik W.

    2013-01-01

    , the number of cabinets and customers and the load per customer. The aim of the model is to design, implement and test the proposed configuration and to investigate whether the low-voltage distribution grid is prepared for the expected future increase of PV penetration, heat pumps and electric cars. The model...

  18. Analysis of the Vibration Spectrum Based on the Input Voltage Spectrum

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Jakobsen, Uffe; Rasmussen, Peter Omand;

    2009-01-01

    on the spectrum of the applied voltage. The measurements show that the spectral components are caused mainly by the modulation, which agrees with the results from the analytical solution. A method to determine the dominant frequency components from the radial force spectrum based on current measurements is also...

  19. L-type Voltage-Gated Calcium Channels in Conditioned Fear: A Genetic and Pharmacological Analysis

    Science.gov (United States)

    McKinney, Brandon C.; Sze, Wilson; White, Jessica A.; Murphy, Geoffrey G.

    2008-01-01

    Using pharmacological approaches, others have suggested that L-type voltage-gated calcium channels (L-VGCCs) mediate both consolidation and extinction of conditioned fear. In the absence of L-VGCC isoform-specific antagonists, we have begun to investigate the subtype-specific role of LVGCCs in consolidation and extinction of conditioned fear…

  20. Modulation Methods for Three-level Neutral-Point-Clamped Inverter Achieving Stress Redistribution under Moderate Modulation Index

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2016-01-01

    This letter investigates the loss and thermal behaviors of a three-level neutral-point-clamped (3L-NPC) inverter undergoing moderate modulation index, which is typically presented during minor voltage sags of the power grid or speed changes of the electric machines. A series of new space vector m...

  1. Single-Carrier Modulation for Neutral-Point-Clamped Inverters in Three-Phase Transformerless Photovoltaic Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Cavalcanti, Marcelo C.; Farias, Alexandre M.;

    2013-01-01

    Modulation strategy is one of the most important issues for three-level neutral-point-clamped inverters in three-phase transformerless photovoltaic systems. A challenge for modulation is how to keep the common-mode voltages constant to reduce the leakage currents. A single-carrier modulation...

  2. POLYCYTHEMIA RISK IN NEONATES WITH DELAYED CORD CLAMPING

    Directory of Open Access Journals (Sweden)

    I Gusti Agung Ayu Sri Wulandari Pramana

    2013-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Delayed Cord Clamping is still a controversial issue in the world of medicine. Until recently, the perfect times to do a Delayed Cord Clamping in various parts of the Earth in the world are still very diverse. There are a few things that became a major concern associated with Delayed Cord Clamping, one of which is the increase in blood volume due to an increase in the number of erythrocytes which led to occurrence of neonatal polycythemia which later can lead to various complications. Polycythemia in neonates is a situation where the value of venous blood hematokrit over 65% (0.65 or the amount of hemoglobin more than 22gr/Dl. However, to date the data from a variety of the latest research and analysis of the studies mention that the polycythemia that occurs in neonates with umbilical cord pinching the flush delay was mild polycythemia that can improve after 48 to 72 hours after the baby is born.

  3. Timing of umbilical cord clamping and neonatal haematological status.

    Science.gov (United States)

    Jaleel, Riffat; Deeba, Farah; Khan, Ayesha

    2009-07-01

    To determine the effect of delayed umbilical cord clamping on Hb (haemoglobin) and bilirubin levels of neonates and to identify newborn babies with anaemia and refer them for treatment. This Randomized Controlled Trial was conducted in the Department of Obstetrics and Gynaecology, Unit V, Dow Medical College and Lyari General Hospital and Department of Pathology, Lyari General Hospital, between 1st November, 2006 and 15th July, 2007. Patients admitted to labour ward were selected according to inclusion criteria of the study. They were randomly allocated to 2 groups. Group A included women in whom umbilical cord was clamped immediately after birth. In Group B, clamping was delayed until cessation of pulsations in the cord. After cutting the cord, sample of blood was collected from the cut end of cord of the newborn for Hb and bilirubin. After 6 hours of birth, another sample of blood was drawn from antecubital vein for serum bilirubin. Samples were sent to laboratory for analysis. All data were entered and analyzed using SPSS version 11. Two hundred women were studied, 100 in each of the 2 groups. Mean maternal Hb was 9.75 g/dl in Group A and 9.95 g/dl in Group B. The average neonatal Hb was 14.1 g/dl in Group A and 15.2 g/dl in Group B (p = 0.008). In all 49% neonates in Group A and 37% in Group B had Hb umbilical cord clamping at birth seems to be safe and can be expected to reduce the prevalence of anaemic newborn babies in our community.

  4. Simple Switching Strategy for High-Torque Control Performance utilizing Neutral Point Clamped Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    Nor Faezah Alias

    2013-12-01

    Full Text Available Three-level Neutral Point Clamped (NPC inverter allows the configuration of switching devices to operate at high voltage and produce lower current/voltage harmonics. It is known that, DTC of induction machine which employs hysteresis controller has major drawbacks namely larger torque ripple and variable switching frequency. This paper aims to propose a suitable voltage vector selection to provide better torque regulation and lower switching frequency by employing DTC with 3-level NPC multilevel inverter. A simple switching strategy was formulated using 7-level torque hysteresis and 2-level flux hysteresis controllers to give more options in selecting an appropriate voltage vector, inherently, according the motor operation conditions. The improvements offered were verified through simulations.

  5. Prolonged penile strangulation with metal clamps

    Institute of Scientific and Technical Information of China (English)

    Chirag Patel; Richard Kim; Michael Delterzo; Run Wang

    2006-01-01

    Various different objects have been reported to strangulate the penis. We reported on a patient who used metal radiator clamps for an extended period of time. Workup included history, physical examination and urinalysis. The patient was taken to the operating room for further evaluation with cystourethroscopy and orthopedic wire cutters were used to break the metal bands.

  6. The Effect of an Added Mass on the Frequency Shifts of a Clamped-Clamped Microbeam for Bio-Mass Detection

    KAUST Repository

    Bouchaala, Adam M.

    2016-12-05

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped-clamped microbeams due to an added mass. Based on the Euler-Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes.

  7. Cerebral haemodynamics during carotid cross-clamping.

    Science.gov (United States)

    Pistolese, G R; Ippoliti, A; Appolloni, A; Ronchey, S; Faraglia, V

    1993-03-01

    Carotid artery cross-clamping ischaemia during carotid endarterectomy (CEA) causes 5-30% of perioperative neurological deficits. This study was performed to identify possible clinical situations at higher risk for carotid cross-clamping ischaemia. 606 consecutive patients underwent CEA and were retrospectively studied; they were grouped according to risk factors, presence of associated vascular diseases, clinical pattern, angiographic and CT scan findings. Stump pressure measurement was provided in all patients, perioperative monitoring during CEA was performed by electroencephalogram (EEG) in 469 (77%) and somatosensorial evoked potentials (SEP) in 137 (23%). Local anaesthesia was used in 88 (14.5%) patients. Ischaemic changes during carotid cross-clamping were registered in 118 patients (19.5%). The incidence of cross-clamping ischaemia was then related to different factors; it affected 5.6% of asymptomatics, 25.4% of patients with fixed stroke and 38.5% of those with stenosis and contralateral occlusion. Angiographic and clinical correlation showed that patients with more severe lesions are mostly affected by clamping ischaemia (up to 55% in those with stroke and stenosis with contralateral occlusion). Age, hypertension and diabetes do not significantly affect incidence of ischaemic changes. Positive CT scan increased this risk; statistical relevance was found in regard to patients with unilateral or bilateral stenosis and in those with transient ischaemic attacks. A higher risk can be expected for subjects with more severe clinical and instrumental findings, even if no patients can be considered completely at risk or risk free. Perioperative monitoring is always mandatory and is of great importance in detecting ischaemic changes and preventing cerebral damage using a temporary intraluminal shunt.

  8. 木薯收获机夹持输送机构设计与力学分析%Design and Mechanics Analysis of Clamping-Conveying Mechanism of Cassava Harvester

    Institute of Scientific and Technical Information of China (English)

    余瑞明; 廖宇兰; 刘世豪; 王涛; 袁成宇

    2015-01-01

    针对现有挖拔式木薯收获机夹持输送机构出现夹持掉带掉薯、夹持对中困难及木薯茎秆难以进入夹持输送机构等问题,研究设计了夹持输送机构。该机构采用拉簧安装在移动杆凹槽内,移动杆与机架间为移动副连接的方式夹紧木薯茎秆,并将其与摇杆与机架间为转动副连接的方式进行了对比分析。结果表明:移动副连接使拉簧的拉力全部提供为夹持力,无拉力损失,夹持力最大;同时,自动调节带间距,夹持牢固。根据土薯生物环境特性,设计了夹持轮、带轮、夹持带、张紧装置和导向装置等主要结构,并对各结构进行了分析,确定了主要结构参数。根据木薯块根拔起时的速度分解图,建立了块根拔起时的力学模型,且通过分析推导得到了夹持输送机构对块根的拔起力和对茎秆的夹持力计算公式。该研究对于快速拔出、输送薯块、减少薯块损失、降低伤薯率、提高挖拔式木薯收获机整机性能具有重要意义。%Aiming at the existing problems of dropping off during clamping,dropping off of cassava,difficulty to clamp in the middle point,difficulty to feed cassava stem to clamping-conveying mechanism of digging-pulling cassava harvest,a kind of clamping-conveying mechanism is designed.Tension-spring is installed inside a shift rod groove.The cassava stem is clamped tightly between wheels being installed the shifting rod and frame.The shifting rod can shift on the frame by shifting pair.Compare with the revolving pair between the rocker and frame,the shifting pair make the power of ten-sion-spring turn to clamping-power fully,no any loss,get maximum clamping force.At the same time the spacing of two belts can be adjusted automatically,and the cassava stem may be clamped firmly.According to the biological and environ-mental characteristics of cassava,main structure such as clamping-wheel,belt-wheel,clamping

  9. Capacitance-voltage analysis of a high-k dielectric on silicon

    Institute of Scientific and Technical Information of China (English)

    Davinder Rathee; Sandeep K. Arya; Mukesh Kumar

    2012-01-01

    Device characteristics of TiO2 gate dielectrics deposited by a sol-gel method and DC sputtering method on a P-type silicon wafer are reported.Metal-oxide-semiconductor capacitors with Al as the top electrode were fabricated to study the electrical properties of TiO2 films.The films were physically characterized by using X-ray diffraction,a capacitor voltage measurement,scanning electron microscopy,and by spectroscopy ellipsometry.The XRD and DST-TG indicate the presence of an anatase TiO2 phase in the film.Films deposited at higher temperatures showed better crystallinity.The dielectric constant calculated using the capacitance voltage measurement was found to be 18 and 73 for sputtering and sol-gel samples respectively.The refractive indices of the films were found to be 2.16 for sputtering and 2.42 for sol-gel samples.

  10. Charge collection and capacitance-voltage analysis in irradiated n-type magnetic Czochralski silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Petterson, M.K.; Sadrozinski, H.F.-W.; Betancourt, C. [SCIPP UC Santa Cruz, 1156 High Street, 95064 CA (United States); Bruzzi, M. [INFN, Dipartimento di Energetica, Universita di Firenze, via S. Marta 3, 50139 Florence (Italy)], E-mail: mara.bruzzi@unifi.it; Scaringella, M.; Tosi, C.; Macchiolo, A. [INFN, Dipartimento di Energetica, Universita di Firenze, via S. Marta 3, 50139 Florence (Italy); Manna, N.; Creanza, D. [Universita di Bari (Italy); Boscardin, M.; Piemonte, C.; Zorzi, N. [ITC, IRST, Povo, Trento (Italy); Borrello, L.; Messineo, A. [INFN Pisa (Italy); Dalla Betta, G.F. [Universita di Trento (Italy)

    2007-12-11

    The depletion depth of irradiated n-type silicon microstrip detectors can be inferred from both the reciprocal capacitance and from the amount of collected charge. Capacitance voltage (C-V) measurements at different frequencies and temperatures are being compared with the bias voltage dependence of the charge collection on an irradiated n-type magnetic Czochralski silicon detector. Good agreement between the reciprocal capacitance and the median collected charge is found when the frequency of the C-V measurement is selected such that it scales with the temperature dependence of the leakage current. Measuring C-V characteristics at prescribed combinations of temperature and frequency allows then a realistic estimate of the depletion characteristics of irradiated silicon strip detectors based on C-V data alone.

  11. Analysis of the Light Propagation Model of the Optical Voltage Sensor for Suppressing Unreciprocal Errors.

    Science.gov (United States)

    Li, Hui; Fu, Zhida; Liu, Liying; Lin, Zhili; Deng, Wei; Feng, Lishuang

    2017-01-03

    An improved temperature-insensitive optical voltage sensor (OVS) with a reciprocal dual-crystal sensing method is proposed. The inducing principle of OVS reciprocity degradation is expounded by taking the different temperature fields of two crystals and the axis-errors of optical components into consideration. The key parameters pertaining to the system reciprocity degeneration in the dual-crystal sensing unit are investigated in order to optimize the optical sensing model based on the Maxwell's electromagnetic theory. The influencing principle of axis-angle errors on the system nonlinearity in the Pockels phase transfer unit is analyzed. Moreover, a novel axis-angle compensation method is proposed to improve the OVS measurement precision according to the simulation results. The experiment results show that the measurement precision of OVS is superior to ±0.2% in the temperature range from -40 °C to +60 °C, which demonstrates the excellent temperature stability of the designed voltage sensing system.

  12. Pull-in behavior analysis of vibrating functionally graded micro-cantilevers under suddenly DC voltage

    Directory of Open Access Journals (Sweden)

    Jamal Zare

    2015-01-01

    Full Text Available The present research attempts to explain dynamic pull-in instability of functionally graded micro-cantilevers actuated by step DC voltage while the fringing-field effect is taken into account in the vibrational equation of motion. By employing modern asymptotic approach namely Homotopy Perturbation Method with an auxiliary term, high-order frequency-amplitude relation is obtained, then the influences of material properties and actuation voltage on dynamic pull-in behavior are investigated. It is demonstrated that the auxiliary term in the homotopy perturbation method is extremely effective for higher order approximation and two terms in series expansions are sufficient to produce an acceptable solution. The strength of this analytical procedure is verified through comparison with numerical results.

  13. Low Driving Voltage and Analysis of Azobenzene Polymer Doped Liquid Crystal Grating

    Institute of Scientific and Technical Information of China (English)

    SONG Jing; LIU Yong-Gang; MA Ji; XUAN Li

    2006-01-01

    We mix azobenzene polymer and liquid crystal in certain ratio. Then the mixture is injected into cells. Nonlinearly photoinduced birefringence takes place when linearly polarized ultraviolet is applied with the pattern photomask covering on the cells, which results in the formation of azobenzene polymer doped liquid crystalgrating. The obtained grating is characterized by an optical microscope and a He-Ne laser. The results indicate that the samples have clear grating structure, and the diffraction efficiencies can be modulated by electric field. The sample driving voltage is 0.6 V/μm. It is lower than the driving voltage of holographic polymer dispersed liquid crystal transmission grating and could be matched with the driving integrated circuit.

  14. Effects of Delayed Umbilical Cord Clamping vs Early Clamping on Anemia in Infants at 8 and 12 Months: A Randomized Clinical Trial.

    Science.gov (United States)

    Kc, Ashish; Rana, Nisha; Målqvist, Mats; Jarawka Ranneberg, Linda; Subedi, Kalpana; Andersson, Ola

    2017-03-01

    Delayed umbilical cord clamping has been shown to improve iron stores in infants to 6 months of age. However, delayed cord clamping has not been shown to prevent iron deficiency or anemia after 6 months of age. To investigate the effects of delayed umbilical cord clamping, compared with early clamping, on hemoglobin and ferritin levels at 8 and 12 months of age in infants at high risk for iron deficiency anemia. This randomized clinical trial included 540 late preterm and term infants born vaginally at a tertiary hospital in Kathmandu, Nepal, from October 2 to November 21, 2014. Follow-up included blood levels of hemoglobin and ferritin at 8 and 12 months of age. Follow-up was completed on December 11, 2015. Analysis was based on intention to treat. Infants were randomized to delayed umbilical cord clamping (≥180 seconds after delivery) or early clamping (≤60 seconds after delivery). Main outcomes included hemoglobin and anemia levels at 8 months of age with the power estimate based on the prevalence of anemia. Secondary outcomes included hemoglobin and anemia levels at 12 months of age and ferritin level, iron deficiency, and iron deficiency anemia at 8 and 12 months of age. In this study of 540 infants (281 boys [52.0%] and 259 girls [48.0%]; mean [SD] gestational age, 39.2 [1.1] weeks), 270 each were randomized to the delayed and early clamping groups. At 8 months of age, 212 infants (78.5%) from the delayed group and 188 (69.6%) from the early clamping group returned for blood sampling. After multiple imputation analysis, infants undergoing delayed clamping had higher levels of hemoglobin (10.4 vs 10.2 g/dL; difference, 0.2 g/dL; 95% CI, 0.1 to 0.4 g/dL). Delayed cord clamping also reduced the prevalence of anemia (hemoglobin level clamping group in 60 (22.2%) vs 103 (38.1%) patients (relative risk, 0.58; 95% CI, 0.44-0.77; NNT, 6; 95% CI, 4-13). At 12 months, delayed cord clamping still resulted in a hemoglobin level of 0.3 (95% CI, 0.04-0.5) g/dL higher

  15. Dynamics and Stability of Pinned-Clamped and Clamped-Pinned Cylindrical Shells Conveying Fluid

    Science.gov (United States)

    Misra, A. K.; Wong, S. S. T.; Païdoussis, M. P.

    2001-11-01

    The paper examines the dynamics and stability of fluid-conveying cylindrical shells having pinned-clamped or clamped-pinned boundary conditions, where ``pinned'' is an abbreviation for ``simply supported''. Flügge's equations are used to describe the shell motion, while the fluid-dynamic perturbation pressure is obtained utilizing the linearized potential flow theory. The solution is obtained using two methods - the travelling wave method and the Fourier-transform approach. The results obtained by both methods suggest that the negative damping of the clamped-pinned systems and positive damping of the pinned-clamped systems, observed by previous investigators for any arbitrarily small flow velocity, are simply numerical artefacts; this is reinforced by energy considerations, in which the work done by the fluid on the shell is shown to be zero. Hence, it is concluded that both systems are conservative.

  16. Detection of Disturbances in Voltage Signals for Power Quality Analysis Using HOS

    Directory of Open Access Journals (Sweden)

    Pereira José Luiz R

    2007-01-01

    Full Text Available This paper outlines a higher-order statistics (HOS-based technique for detecting abnormal conditions in voltage signals. The main advantage introduced by the proposed technique refers to its capability to detect voltage disturbances and their start and end points in a frame whose length corresponds to, at least, samples or of the fundamental component if a sampling rate equal to Hz is considered. This feature allows the detection of disturbances in submultiples or multiples of one-cycle fundamental component if an appropriate sampling rate is considered. From the computational results, one can note that almost all abnormal and normal conditions are correctly detected if s256, 128, 64, 32, and 16 and the SNR is higher than 25 dB. In addition, the proposed technique is compared to a root mean square (rms-based technique, which was recently developed to detect the presence of some voltage events as well as their sources in a frame whose length ranges from up to one-cycle fundamental component. The numerical results reveal that the proposed technique shows an improved performance when applied not only to synthetic data, but also to real one.

  17. PATCH-CLAMP ANALYSIS OF THE DOMINANT PLASMA-MEMBRANE K+ CHANNEL IN ROOT CELL PROTOPLASTS OF PLANTAGO-MEDIA L - ITS SIGNIFICANCE FOR THE P-STATE AND K-STATE

    NARCIS (Netherlands)

    VOGELZANG, SA; PRINS, HBA

    1994-01-01

    Ion channels in the plasma membrane of root cell protoplasts of Plantago media L. were studied with the patch clamp technique in the cell-attached patch and outside-out patch configuration. An outward rectifying potassium channel was dominantly present in the plasma membrane. It appears responsible

  18. DC Bus Control of Back-to-Back Connected Two-Level PWM Rectifier-Five-Level NPC Voltage Source Inverter to Torque Ripple Reduction in Induction Motor

    Directory of Open Access Journals (Sweden)

    Abdelkrim Thameur

    2015-01-01

    Full Text Available This paper proposes a regulation method of back-to-back connected two-level PWM rectifier-five-level Voltage Source Inverter (VSI in order to reduce the torque ripple in induction motor. First part is dedicated to the presentation of the feedback control of two-level PWM rectifier. In the second part, five-level Neutral Point Clamped (NPC voltage source inverter balancing DC bus algorithm is presented. A theoretical analysis with a complete simulation of the system is presented to prove the excellent performance of the proposed technique.

  19. Loading Analysis of Modular Multi-level Converter for Offshore High-voltage DC Application under Various Grid Faults

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang;

    2016-01-01

    The modular multi-level converter has become an interesting candidate in high-voltage DC systems due to its higher voltage levels and modular construction. Low-voltage ride-through is an important grid requirement for modular multi-level converter–high-voltage DC since not only causes control cha...... be of importance for the design of the cooling system....

  20. Analysis of energy quality problems in low voltage circuits; Analise de problemas de qualidade da energia em circuitos de baixa tensao

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Hermes R.P.M. de; Jesus, Nelson C. de; Figueiredo, Carlos E.C. [AES Sul, Porto Alegre, RS (Brazil); Batista, Edson L. [Universidade Regional do Noroeste do Estado do Rio Grande do Sul, Inijui, RS (Brazil); Martinez, Manuel L.B. [Universidade Federal de Itajuba (UNIFEI), MG (Brazil)

    2005-12-15

    This article presents an analysis and diagnosis related to a typical commercial consumer with problems of energy quality, supplied by low voltage net. In this direction, after the supplied voltage to have been monitored through specific analysers and careful investigations, it was concluded that the origin of disturbances was located in the consumer systems. The main steps used in the analysis and measurements results are described.

  1. PWM Regulation of Grid-Tied PV System on the Base of Photovoltaic-Fed Diode-Clamped Inverters

    Directory of Open Access Journals (Sweden)

    Oleschuk V.I.

    2015-12-01

    Full Text Available Investigation of grid-tied photovoltaic system on the base of two diode-clamped inverters, controlled by specific algorithms of pulse-width modulation (PWM, has been done. This system includes two strings of photovoltaic panels feeding two diode-clamped inverters. The outputs of inverters are connected with the corresponding windings on the primary side of three-phase transformer, connected with a grid. In order to reduce phase voltage distortion and to increase efficiency of operation of the system, special scheme of control and modulation of inverters has been used, providing minimization of common-mode voltages and voltage waveforms symmetries under different operating conditions. Detailed simulation of processes in this photovoltaic-fed power conversion system has been executed. The results of simulations verify good performance of photovoltaic system regulated in accordance with specific strategy of control and modulation.

  2. Towards a Dynamic Clamp for Neurochemical Modalities

    Directory of Open Access Journals (Sweden)

    Catalina Maria Rivera

    2015-05-01

    Full Text Available The classic dynamic clamp technique uses a real-time electrical interface between living cells and neural simulations in order to investigate hypotheses about neural function and structure. One of the acknowledged drawbacks of that technique is the limited control of the cells’ chemical microenvironment. In this manuscript, we use a novel combination of nanosensor and microfluidic technology and microfluidic and neural simulations to add sensing and control of chemical concentrations to the dynamic clamp technique. Specifically, we use a microfluidic lab-on-a-chip to generate distinct chemical concentration gradients (ions or neuromodulators, to register the concentrations with embedded nanosensors and use the processed signals as an input to simulations of a neural cell. The ultimate goal of this project is to close the loop and provide sensor signals to the microfluidic lab-on-a-chip to mimic the interaction of the simulated cell with other cells in its chemical environment.

  3. Analysis of electric field control methods for foil coils in high-voltage linear actuators

    Directory of Open Access Journals (Sweden)

    Beek T.A. van

    2015-12-01

    Full Text Available This paper describes multiple electric field control methods for foil coils in high-voltage coreless linear actuators and their sensitivity to misalignment. The investigated field control methods consist of resistive, refractive, capacitive and geometrical solutions for mitigating electric stress at edges and corners of foil coils. These field control methods are evaluated using 2-D boundary element and finite element methods. A comparison is presented between the field control methods and their ability to mitigate electric stress in coreless linear actuators. Furthermore, the sensitivity to misalignment of the field control methods is investigated.

  4. Stability analysis and design of the improved droop controller on a voltage source inverter

    DEFF Research Database (Denmark)

    Calabria, Mauro; Schumacher, Walter; Guerrero, Josep M.;

    2015-01-01

    This paper studies the dynamics of a droop-controlled voltage source inverter connected to a stiff grid and addresses the use of the improved droop controller in order to enhance the dynamic behavior of the system. The small-signal stability of the inverter is studied in depth considering...... variations on its droop parameters, providing a general understanding on the functioning of such system. Finally, three methods to tune the dynamic droop gain are introduced and compared, providing analytical, simulation, and experimental results....

  5. Mechanical and metallurgical properties of carotid artery clamps.

    Science.gov (United States)

    Dujovny, M; Kossovsky, N; Kossowsky, R; Segal, R; Diaz, F G; Kaufman, H; Perlin, A; Cook, E E

    1985-11-01

    The mechanical and metallurgical properties of carotid artery clamps were evaluated. The pressure plate retreat propensity, metallurgical composition, surface morphology, magnetic properties, and corrosion resistance of the Crutchfield, Selverstone, Salibi, and Kindt clamps were tested. None of the clamps showed evidence of pressure plate retreat. The clamps differed significantly in their composition, surface cleanliness, magnetic properties, and corrosion resistance. The Crutchfield clamp was the only one manufactured from an ASTM-ANSI-approved implantable stainless steel (AISI 316) and the only clamp in which the surfaces were clean and free of debris. The Selverstone clamp was made principally from AISI 304 stainless steel, as was one Salibi clamp. The pressure plate on another Salibi clamp was made from a 1% chromium and 1% manganese steel. Machining and surface debris consisting principally of aluminum, silicon, and sulfur was abundant on the Selverstone and Salibi clamps. The Kindt clamp was manufactured from AISI 301 stainless steel with a silicate-aluminized outer coating. The Crutchfield and Selverstone clamps were essentially nonferromagnetic, whereas the Salibi and Kindt clamps were sensitive to magnetic flux. In the pitting potential corrosion test, the Crutchfield clamp demonstrated good corrosion resistance with a pitting potential of 310 mV and no surface corrosion or pitting by scanning electron microscopy examination. The Selverstone clamp had lower pitting potentials and showed various degrees of corrosion and surface pitting by scanning electron microscopy. The Salibi pressure plate had a very low pitting potential of -525 mV and showed severe corrosion. By metallurgical criteria, only the Crutchfield clamp is suitable for long term implantation.

  6. High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

    DEFF Research Database (Denmark)

    Kejian, Song; Konstantinou, Georgios; Jing, Li

    2017-01-01

    Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric...... multiple unit traction system is proposed in this study. The strategy is based on a multiple frequency tuned quasi-proportional resonant controller in the ac-side current loop and a multiple frequency tuned notch filter in the dc-link voltage loop. Under the typical supply voltage distortion present...

  7. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...... and better output performance comparing with traditional two-level inverters. Integrating these two types of configurations can help neutral point inverters achieve enhanced votlage buck-boost capability....

  8. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...... the first and second substantially rigid element. Hereby the flow rate through the active valve can be continuously and precisely controlled....

  9. Indirect Field Oriented Control for Five Phase Three Level Neutral Point Clamped Inverter Fed PMSM Drive

    Directory of Open Access Journals (Sweden)

    S. Sengottaian

    2015-08-01

    Full Text Available This study deals with a five phase three level Neutral Point Clamped (NPC inverter fed PMSM drive application. The motor performances depend upon mathematical model so the parameters vary are: noise, common mode voltage, flux variation and harmonic levels of the inverter or motor. Voltage saturation is one of the major problems of a motor which occurs due to speed oscillations, more current fluctuations. This problem can be solved by using PWM technique depends on the reference motor torque and flux. In this study Indirect Field Oriented Control (IFOC NPC inverter is suggested to reduce the voltage saturation. The three level neutral point clamped inverter is widely used for medium and high level applications. Compared with standard two level inverter, this type of NPC inverters have more merits. It generates greater number of levels output waveform in lower harmonic content at the same switching frequency and less voltage stress across the semiconductor switches; finally motor performance and control schemes are verified by using MATLAB/SIMULINK.

  10. A novel monolithic piezoelectric actuated flexure-mechanism based wire clamp for microelectronic device packaging

    Science.gov (United States)

    Liang, Cunman; Wang, Fujun; Tian, Yanling; Zhao, Xingyu; Zhang, Hongjie; Cui, Liangyu; Zhang, Dawei; Ferreira, Placid

    2015-04-01

    A novel monolithic piezoelectric actuated wire clamp is presented in this paper to achieve fast, accurate, and robust microelectronic device packaging. The wire clamp has compact, flexure-based mechanical structure and light weight. To obtain large and robust jaw displacements and ensure parallel jaw grasping, a two-stage amplification composed of a homothetic bridge type mechanism and a parallelogram leverage mechanism was designed. Pseudo-rigid-body model and Lagrange approaches were employed to conduct the kinematic, static, and dynamic modeling of the wire clamp and optimization design was carried out. The displacement amplification ratio, maximum allowable stress, and natural frequency were calculated. Finite element analysis (FEA) was conducted to evaluate the characteristics of the wire clamp and wire electro discharge machining technique was utilized to fabricate the monolithic structure. Experimental tests were carried out to investigate the performance and the experimental results match well with the theoretical calculation and FEA. The amplification ratio of the clamp is 20.96 and the working mode frequency is 895 Hz. Step response test shows that the wire clamp has fast response and high accuracy and the motion resolution is 0.2 μm. High speed precision grasping operations of gold and copper wires were realized using the wire clamper.

  11. Can selective arterial clamping with fluorescence imaging preserve kidney function during robotic partial nephrectomy?

    Science.gov (United States)

    McClintock, Tyler R; Bjurlin, Marc A; Wysock, James S; Borofsky, Michael S; Marien, Tracy P; Okoro, Chinonyerem; Stifelman, Michael D

    2014-08-01

    To compare renal functional outcomes in robotic partial nephrectomy (RPN) with selective arterial clamping guided by near-infrared fluorescence (NIRF) imaging to a matched cohort of patients who underwent RPN without selective arterial clamping and NIRF imaging. From April 2011 to December 2012, NIRF imaging-enhanced RPN with selective clamping was used in 42 cases. Functional outcomes of successful cases were compared with a cohort of patients, matched by tumor size, preoperative estimated glomerular filtration rate (eGFR), functional kidney status, age, sex, body mass index, and American Society of Anesthesiologists score, who underwent RPN without selective clamping and NIRF imaging. In matched-pair analysis, selective clamping with NIRF was associated with superior kidney function at discharge, as demonstrated by postoperative eGFR (78.2 vs 68.5 mL/min/1.73 m(2); P = .04), absolute reduction of eGFR (-2.5 vs -14.0 mL/min/1.73 m(2); P functional outcomes when compared with RPN without selective arterial clamping and NIRF imaging. With this effect attenuated at later follow-up, randomized prospective studies and long-term assessment of kidney-specific functional outcomes are needed to further assess the benefits of this technology. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Pulsewidth Modulation of Neutral-Point-Clamped Indirect Matrix Converter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Poh Chiang, Loh; Gao, Feng

    2008-01-01

    discussed in the existing literature. Addressing the previously described issues, this paper focuses on the operational mode analysis of a three-level indirect matrix converter implemented using a neutral-point-clamped inversion stage and the design of a number of PWM and modulation ratio compensation...... schemes for controlling the converter with improved waveform quality. The performances and practicalities of the designed schemes are verified in simulation and experimentally using an implemented laboratory prototype with some representative results captured and presented in this paper....

  13. Vibration of an eccentrically clamped annular plate

    Science.gov (United States)

    Tseng, J.-G.; Wickert, J. A.

    1994-04-01

    Small amplitude vibration of an eccentric annular plate, which is free along its outer edge and clamped along the interior, is investigated through experimental and analytical methods. A disk with this geometry, or a stacked array in which the clamping and symmetry axes of each disk are nominally coincident, is common in data storage and brake systems applications. In the present case, the geometric imperfections on the boundary can have important implications for the disk's dynamic response. Changes that occur in the natural frequency spectrum, the mode shapes, and the free response under eccentric mounting are studied through laboratory measurements and an approximate discrete model of the plate. The natural frequencies and modes are found through global discretization of the Kamke quotient for a classical thin plate. For the axisymmetric geometry, the natural frequencies of the sine and cosine vibration modes for a specified number of nodal diameters are repeated. With increasing eccentricity, on the other hand, each pair of repeated frequencies splits at a rate that depends on the number of nodal diameters. Over a range of clamping and eccentricity ratios, the model's predictions are compared to the measured results.

  14. Multilevel-clamped multilevel converters (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Bellar, Maria Dias; Muñoz-Aguliar, Raúl Santiago;

    2012-01-01

    This letter introduces a new series of multilevel (ML) converters based on the ML clamping concept. By applying this technique, a ML clamping unit (MCU) conveys additional levels for synthesizing the output waveforms of a diode-clampedML dc– ac power converter. The basic building block of the ML ...

  15. Single molecule study of a processivity clamp sliding on DNA

    Energy Technology Data Exchange (ETDEWEB)

    Laurence, T A; Kwon, Y; Johnson, A; Hollars, C; O?Donnell, M; Camarero, J A; Barsky, D

    2007-07-05

    Using solution based single molecule spectroscopy, we study the motion of the polIII {beta}-subunit DNA sliding clamp ('{beta}-clamp') on DNA. Present in all cellular (and some viral) forms of life, DNA sliding clamps attach to polymerases and allow rapid, processive replication of DNA. In the absence of other proteins, the DNA sliding clamps are thought to 'freely slide' along the DNA; however, the abundance of positively charged residues along the inner surface may create favorable electrostatic contact with the highly negatively charged DNA. We have performed single-molecule measurements on a fluorescently labeled {beta}-clamp loaded onto freely diffusing plasmids annealed with fluorescently labeled primers of up to 90 bases. We find that the diffusion constant for 1D diffusion of the {beta}-clamp on DNA satisfies D {le} 10{sup -14} cm{sup 2}/s, much slower than the frictionless limit of D = 10{sup -10} cm{sup 2}/s. We find that the {beta} clamp remains at the 3-foot end in the presence of E. coli single-stranded binding protein (SSB), which would allow for a sliding clamp to wait for binding of the DNA polymerase. Replacement of SSB with Human RP-A eliminates this interaction; free movement of sliding clamp and poor binding of clamp loader to the junction allows sliding clamp to accumulate on DNA. This result implies that the clamp not only acts as a tether, but also a placeholder.

  16. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460 Section 882.4460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used...

  17. Analysis and Estimation of Values of Currents and Voltages at the Disturbances in Induction Machine Using Tested Matlab Simulation

    Directory of Open Access Journals (Sweden)

    Nenad Marković

    2014-12-01

    Full Text Available The paper we presents mathematical model for analysis of transitional processes in three-phase induction motor, that is, wave forms of currents and voltages in time domain and phase coordinates. Model is suitable for relay protection of the motor from disturbances and for estimation of electrical energy quality in the distribution network. New constructions of induction motors present more progressive technical solutions comparing with classical variants and reliable entity only within selected system of protection from expected disturbances (failures and disorders followed by asymmetries. Measuring process is not required due to application of simulation in selected MATLAB package.

  18. Analysis of the selectivity filter of the voltage-gated sodium channel NavRh

    Institute of Scientific and Technical Information of China (English)

    Xu Zhang; Mengdie Xia; Yang Li; Huihui Liu; Xin Jiang; Wenlin Ren; Jianping Wu

    2013-01-01

    NaChBac is a bacterial voltage-gated sodium (Nav) channel that shows sequence similarity to voltage-gated calcium channels.To understand the ion-permeation mechanism of Nav channels,we combined molecular dynamics simulation,structural biology and electrophysiological approaches to investigate the recently determined structure of NavRh,a marine bacterial NaChBac ortholog.Two Na+ binding sites are identified in the selectivity filter (SF) in our simulations:The extracellular Na+ ion first approaches site 1 constituted by the side groups of Ser181 and Glu183,and then spontaneously arrives at the energetically more favorable site 2 formed by the carbonyi oxygens of Leu179 and Thr178.In contrast,Ca2+ ions are prone to being trapped by Glu183 at site 1,which then blocks the entrance of both Na+ and Ca2+ to the vestibule of the SF.In addition,Na+ permeates through the selective filter in an asymmetrical manner,a feature that resembles that of the mammalian Nav orthologs.The study reported here provides insights into the mechanism of ion selectivity on Na+ over Ca2+ in mammalian Nav channels.

  19. Response analysis of dielectric elastomer spherical membrane to harmonic voltage and random pressure

    Science.gov (United States)

    Jin, Xiaoling; Wang, Yong; Chen, Michael Z. Q.; Huang, Zhilong

    2017-03-01

    Spherical membranes consisting of dielectric elastomer play important roles in flexible and stretchable devices, such as flexible actuators, sensors and loudspeakers. Executing various functions of devices depends on the dynamical behaviors of dielectric elastomer spherical membranes to external electrical and/or mechanical excitations. This manuscript concentrates on the random aspect of dielectric elastomer spherical membranes, i.e., the random response to combined excitations of harmonic voltage and random pressure. To analytically evaluate the response statistics of the stretch ratio, a specific transformation and stochastic averaging technique are successively adopted to solve the strongly nonlinear equation with respect to the stretch ratio. The stochastic differential equations for the system first integral and the phase difference between harmonic excitation and response are first derived through this transformation. The Fokker-Planck-Kolmogorov equation with respect to the stationary probability density of the system first integral and the phase difference is obtained. The stationary probability densities and the response statistics of the stretch ratio and its rate of change are then subsequently calculated. The phenomenon of stochastic jumps is found and the stochastic jump bifurcates with the variations of the frequency and the amplitude of the harmonic voltage and the intensity of the random pressure. The efficacy and accuracy of the analytical results are verified by comparing with the results from Monte Carlo simulation. Besides, the reliability of the dielectric elastomer spherical membrane is discussed briefly. The obtained results could provide options in implementing and designing dielectric elastomer structures for dynamic applications.

  20. Analysis of the match problem of a capacitive voltage divider with a long measurement cable

    Science.gov (United States)

    Yu, Bin-Xiong; Li, Rui; Su, Jian-Cang; Zhao, Liang; Zhang, Yu; Zheng, Lei; Zeng, Bo; Cheng, Jie; Gao, Peng-Cheng; Qiu, Xu-Dong; Xu, Xu-dong

    2017-09-01

    Research is carried out on the basis of the traditional two-end matched circuit of a capacitive voltage divider with a long measurement cable. Transmission progress in the circuit is analyzed theoretically. A match condition of the circuit is acquired, which requires that the circuit satisfies two conditions: (1) the measurement error should be small for a pulse with a duration of less than twice the delay time of the measurement cable; (2) the initial division ratio and the stable division ratio of the circuit are the same. Two matched methods of the circuit are acquired, including the first-order matched method and the second-order matched method. Numerical simulations are carried out. According to the simulation results, the relative errors of the circuits with a cable of 20 m are less than 1.5%, obtained by using both match methods for measurement of rectangular pulses with rise and fall times of 5 ns. An improved circuit is presented, which is suitable for any situation where the low-voltage capacitance of the capacitive divider is even smaller than the capaictance of the measurement cable. A verification experment is carried out, and the test result confirms the simulation result.

  1. Analysis of the Light Propagation Model of the Optical Voltage Sensor for Suppressing Unreciprocal Errors

    Science.gov (United States)

    Li, Hui; Fu, Zhida; Liu, Liying; Lin, Zhili; Deng, Wei; Feng, Lishuang

    2017-01-01

    An improved temperature-insensitive optical voltage sensor (OVS) with a reciprocal dual-crystal sensing method is proposed. The inducing principle of OVS reciprocity degradation is expounded by taking the different temperature fields of two crystals and the axis-errors of optical components into consideration. The key parameters pertaining to the system reciprocity degeneration in the dual-crystal sensing unit are investigated in order to optimize the optical sensing model based on the Maxwell's electromagnetic theory. The influencing principle of axis-angle errors on the system nonlinearity in the Pockels phase transfer unit is analyzed. Moreover, a novel axis-angle compensation method is proposed to improve the OVS measurement precision according to the simulation results. The experiment results show that the measurement precision of OVS is superior to ±0.2% in the temperature range from −40 °C to +60 °C, which demonstrates the excellent temperature stability of the designed voltage sensing system. PMID:28054951

  2. A general modelling and control algorithm of a three-phase multilevel diode clamped inverter by means of a direct space vector control

    Science.gov (United States)

    Bouhali, O.; Francois, B.; Berkouk, E. M.; Saudemont, C.

    2005-07-01

    This paper presents a simple and general direct modulation strategy that enables to copy directly modulated waveforms onto output voltages of a multilevel three-phase Diode Clamped Inverter (DCI). A general modelling of this converter is presented. A space vector scheme is developed without using Park transforms. Based on this algorithm, the location of the reference voltage vector is determined and the voltage vectors for the modulation are deduced. Simultaneously, their durations are calculated. The proposed algorithm is general and can be directly applied to a (n+1) levels inverter independently on its topology (Diode Clamped Inverter, Neutral Point Clamped, Flying Capacitor Inverter...). To verify this algorithm, both control algorithms of a 5-level DCI and a 11-level DCI are considered and simulation results are given.

  3. Numerical analysis on the effect of voltage change on removing condensed water inside the GDL of a PEM fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Woo [Fuel Cell Technology Development Team, Eco-Technology Center, Hyundai-Kia Motors, Yongin (Korea, Republic of); Kim, Young Sang; Kim, Min Soo [Dept. of Mechanical and Aerospace Engineering, Seoul National University, Seoul (Korea, Republic of); Kim, Min Sung [School of Energy Systems Engineering, Chung-Ang University, Seoul (Korea, Republic of)

    2016-09-15

    Decreasing the voltage of a fuel cell through hydrogen mixing or using low-air stoichiometry ratio is beneficial to remove condensed water inside GDL under flooding condition. In this study, the effect of voltage level of a fuel cell on water distribution in GDL under flooding condition was numerically analyzed. Water content in GDL was dependent on the voltage level of a fuel cell, that is, the water content was low when the cell voltage was maintained low. The effect of voltage change under flooding condition was also simulated. The flow rate of condensed water inside GDL considerably increased immediately after decreasing the cell voltage. The oxygen concentration in the catalyst layer was increased by decreasing the voltage of the fuel cell. Consequently, the cell voltage was recovered. Therefore, decreasing cell voltage under flooding condition can facilitate removal of condensed water in GDL.

  4. Analysis of arc emission spectra of stainless steel electric arc furnace slag affected by fluctuating arc voltage.

    Science.gov (United States)

    Aula, Matti; Mäkinen, Ari; Fabritius, Timo

    2014-01-01

    Control of chromium oxidation in the electric arc furnace (EAF) is a significant problem in stainless steel production due to variations of the chemical compositions in the EAF charge. One potential method to control chromium oxidation is to analyze the emission spectrum of the electric arc in order to find indicators of rising chromium content in slag. The purpose of this study was to determine if slag composition can be gained by utilizing electric arc emission spectra in the laboratory environment, despite electric arc voltage fluctuations and varying slag composition. The purpose of inducing voltage fluctuation was to simulate changes in the industrial EAF process. The slag samples were obtained from Outokumpu Stainless Oy Tornio Works, and three different arc currents were used. The correlation analysis showed that the emission spectra offer numerous peak ratios with high correlations to the X-ray fluorescence-measured slag CrO(x)/FeO(x) and MnO/SiO2 ratios. These ratios are useful in determining if the reduction agents have been depleted in the EAF. The results suggest that analysis of laboratory-scale electric arc emission spectra is suitable for indicating the high CrO(x) or MnO content of the slag despite the arc fluctuations. Reliable analysis of other slag components was not successful.

  5. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  6. 中压电缆终端高频电热老化试验装置的研制及分析%Development and analysis of experimental setup under high frequency voltage for medium voltage cable termination

    Institute of Scientific and Technical Information of China (English)

    周凯; 吴迎霞; 陶霰韬; 赵威; 李旭涛

    2011-01-01

    中压电缆终端被广泛应用于柔性交流输电和作为逆变器和电机的连接中,这些电缆终端可能会遭受到高频谐波电压的冲击,从而导致其绝缘迅速失效.本文研制了模拟电网高频谐波电压和工频大电流的电热老化试验装置.首先,通过信号发生器和功率放大器产生低压大电流信号,再通过高频变压器升压获得高频高压;同时通过工频试验变压器产生工频高压,将工频高压和高频高压同时施加到样本上,形成叠加;并分别在两侧加以滤波器阻止高频和工频高压串入到低压系统;最后通过CT(电流互感器)施加150A左右的大电流模拟实际工况.通过实验和红外热成像结果分析,该装置有助于高频电压下的电缆终端绝缘老化研究.%Medium voltage cable terminations are widely used for flexible AC transmission (FACTS) and for con necting terminations for electric motors driven by inverters. These cable terminations are possibly subjected to high electrical stress because of high frequency voltage components. In this paper, an experimental setup was designed to test cable terminations insulation under high frequency sinusoidal voltage. A signal generator and a power ampli fier were used to generate high frequency voltage and larger output power. The voltage was used for the input of high frequency transformer in order to generate high voltage. Also, work frequency high voltage was generated by work frequency transformer. The two kinds of voltages were both applied to specimens at the same time. As a re sult, a superposition waveform by high frequency and work frequency waveform was formed. Two filters composed of LC components were also needed. Furthermore, to simulate working condition, a current transformer is used to obtain 150A current. Through the analysis of experiment and thermal images, the experimental setup has positive effect on investigating insulation characteristics of cable termination.

  7. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  8. Principle and Fault Analysis of Voltage Regulator Circuit%电压调节器电路原理及故障分析

    Institute of Scientific and Technical Information of China (English)

    索明何

    2015-01-01

    Firstly, the paper explores the essential characteristics of voltage regulator through experiments, and then analyzes the circuit principle of the voltage regulator. The paper finally discusses the fault analysis method of voltage regulator circuit through the cases.%本文首先通过实验探究电压调节器的本质特性,然后分析电压调节器电路原理,最后通过案例探究电压调节器电路的故障分析方法.

  9. The jointing stress analysis of one-shot seal-off high-voltage vacuum interrupters

    Institute of Scientific and Technical Information of China (English)

    Zhao Zhizhong; Zou Jiyan; Cong Jiyuan; Wen Huabin; Sun Hui

    2006-01-01

    The free shrinkage of ceramic or metal is restricted due to solidification of the solder. Hence the shrinkage stress arises and the jointing strength is reduced during the brazing of high-voltage vacuum interrupters ( HVVIs ) . The solder bound contour was gained by solved energy bound equation. The finite element model of weld beads was established with Surface Evolver software. Then the stress in two different cooling techniques ( natural cooling and force cooling) was calculated with ANSYS. Comparing the stress, a better cooling technique was selected for HVVIs. Its cooling time is shortened by 3 hours while the jointing stress doesn' t increase and the tensile strength of ceramic to metal seal is not decreased. The stress-rupture tests have validated the calculated results. More important, a method is found, by which the brazing technique could be improved in advance instead of blind experiments.

  10. Analysis of Antimicrobial-Triggered Membrane Depolarisation Using Voltage Sensitive Dyes

    Directory of Open Access Journals (Sweden)

    J. Derk te Winkel

    2016-04-01

    Full Text Available The bacterial cytoplasmic membrane is a major inhibitory target for antimicrobial compounds. Commonly, although not exclusively, these compounds unfold their antimicrobial activity by disrupting the essential barrier function of the cell membrane. As a consequence, membrane permeability assays are central for mode of action studies analysing membrane-targeting antimicrobial compounds. The most frequently used in vivo methods detect changes in membrane permeability by following internalization of normally membrane impermeable and relatively large fluorescent dyes. Unfortunately, these assays are not sensitive to changes in membrane ion permeability which are sufficient to inhibit and kill bacteria by membrane depolarization. In this manuscript, we provide experimental advice how membrane potential, and its changes triggered by membrane-targeting antimicrobials can be accurately assessed in vivo. Optimized protocols are provided for both qualitative and quantitative kinetic measurements of membrane potential. At last, single cell analyses using voltage-sensitive dyes in combination with fluorescence microscopy are introduced and discussed.

  11. Simulation Analysis of Transient Earth Voltages Aroused by Partial Discharge in Switchgear

    Directory of Open Access Journals (Sweden)

    Man Yuyan

    2014-01-01

    Full Text Available The authors investigated the properties of Transient Earth Voltages (TEV Aroused by Partial Discharge in Switchgear by Simulation. The mechanism of TEV aroused by partial discharge in switchgears is analyzed. The Finite Integration Theory (FIT was employed to simulate the propagation of TEV in the switchgear. The simulation results show that the pulse width of TEV increases as the pulse width of PD pulse increases and the amplitude of TEV is proportional to the PD pulse amplitude. There are time differences between the TEV signals of different detecting points when the TEV propagating on the switchgear’s surface. Based on the simulation, a method of locating the PD of switchgear is proposed by positioning multi-sensors on the external surface of switchgear.

  12. 电力系统电压稳定分析方法综述%Summary of Power System’ s Voltage Stability Analysis Method

    Institute of Scientific and Technical Information of China (English)

    刘迎迎; 孙毅; 李昕; 陈维伟

    2013-01-01

    This paper studies the definition and classification of voltage stability,introduce static and dynamic analysis method of voltage stability so far with a comprehensive analysis of voltage stability analysis method. The static analysis method include singular value decomposition method, the sensitivity method, the continu-ous power flow method and the collapse point method;the dynamic analysis method include Small perturbation analysis, time-domain simulation method, energy function method and bifurcation theory. And comprehen-sively analyze and evaluate analysis method of voltage stability. we summarize the feature of voltage stability a-nalysis method and look into the future development direction.%详细研究了电压稳定的定义及分类,介绍了静态电压稳定和动态电压稳定分析方法。静态电压稳定分析法包括奇异值分解法、灵敏度法、连续潮流法、崩溃点法;动态电压稳定分析法包括小扰动分析法、时域仿真法、能量函数法和分岔理论。对电压稳定分析方法进行了综合分析和评价,总结了各类分析方法的特点并展望了未来发展方向。

  13. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... analysis, which is simple for computation and requires moderate automation and communication infrastructure. The proposed method is suitable for a hierarchical control structure where a supervisory controller has the provision to adapt the settings of local PV inverter controllers for overall system...

  14. Correlation character of ionic current fluctuations: analysis of ion current through a voltage-dependent potassium single channel.

    Science.gov (United States)

    Tong-Han, Lan; Huang, Xi; Jia-Rui, Lin

    2005-10-03

    The gating of ion channels has widely been modeled by assuming the transition between open and closed states is a memoryless process. Nevertheless, the statistical analysis of an ionic current signal recorded from voltage dependence K(+) single channel is presented. Calculating the sample auto-correlation function of the ionic current based on the digitized signals, rather than the sequence of open and closed states duration time. The results provide evidence for the existence of memory. For different voltages, the ion channel current fluctuation has different correlation attributions. The correlations in data generated by simulation of two Markov models, on one hand, auto-correlation function of the ionic current shows a weaker memory, after a delayed period of time, the attribute of memory does not exist; on the other hand, the correlation depends on the number of states in the Markov model. For V(p)=-60 mV pipette potential, spectral analysis of ion channel current was conducted, the result indicates that the spectrum is not a flat spectrum, the data set from ionic current fluctuations shows considerable variability with a broad 1/f -like spectrum, alpha=1.261+/-0.24. Thus the ion current fluctuations give information about the kinetics of the channel protein, the results suggest the correlation character of ion channel protein nonlinear kinetics regardless of whether the channel is in open or closed state.

  15. Timing of umbilical cord clamping of term infants.

    Science.gov (United States)

    Ceriani Cernadas, José María

    2017-04-01

    For at least over 200 years, multiple controversies have arisen around the timing of umbilical cord clamping. In the past decades, early cord clamping (within the first 15 seconds) had markedly prevailed. Only in the 21st century, randomized controlled trials have demonstrated the benefits of delayed cord clamping (at 2-3 minutes). Delayed cord clamping has been practiced in obstetrics based on the recommendations made by scientific societies and in systematic reviews, which have provided solid evidence to support this practice in term infants. This review describes the most relevant factors supporting the use of delayed cord clamping in term infants. It points out the essential role played by physiological mechanisms which, undoubtedly, allow us to understand the benefits of delayed cord clamping and advise us to wait for what nature has established. Other relevant aspects supporting delayed cord clamping are also described here. Sociedad Argentina de Pediatría.

  16. A central swivel point in the RFC clamp loader controls PCNA opening and loading on DNA.

    Science.gov (United States)

    Sakato, Miho; O'Donnell, Mike; Hingorani, Manju M

    2012-02-17

    Replication factor C (RFC) is a five-subunit complex that loads proliferating cell nuclear antigen (PCNA) clamps onto primer-template DNA (ptDNA) during replication. RFC subunits belong to the AAA(+) superfamily, and their ATPase activity drives interactions between the clamp loader, the clamp, and the ptDNA, leading to topologically linked PCNA·ptDNA. We report the kinetics of transient events in Saccharomyces cerevisiae RFC-catalyzed PCNA loading, including ATP-induced RFC activation, PCNA opening, ptDNA binding, ATP hydrolysis, PCNA closing, and PCNA·ptDNA release. This detailed perspective enables assessment of individual RFC-A, RFC-B, RFC-C, RFC-D, and RFC-E subunit functions in the reaction mechanism. Functions have been ascribed to RFC subunits previously based on a steady-state analysis of 'arginine-finger' ATPase mutants; however, pre-steady-state analysis provides a different view. The central subunit RFC-C serves as a critical swivel point in the clamp loader. ATP binding to this subunit initiates RFC activation, and the clamp loader adopts a spiral conformation that stabilizes PCNA in a corresponding open spiral. The importance of RFC subunit response to ATP binding decreases as RFC-C>RFC-D>RFC-B, with RFC-A being unnecessary. RFC-C-dependent activation of RFC also enables ptDNA binding, leading to the formation of the RFC·ATP·PCNA(open)·ptDNA complex. Subsequent ATP hydrolysis leads to complex dissociation, with RFC-D activity contributing the most to rapid ptDNA release. The pivotal role of the RFC-B/C/D subunit ATPase core in clamp loading is consistent with the similar central location of all three ATPase active subunits of the Escherichia coli clamp loader.

  17. Modeling and Analysis of Mesh Tree Hybrid Power/Ground Networks with Multiple Voltage Supply in Time Domain

    Institute of Scientific and Technical Information of China (English)

    Yi-Ci Cai; Jin Shi; Zu-Ying Luo; Xian-Long Hong

    2005-01-01

    This paper proposes a novel algorithm, which can be used to model and analyze mesh tree hybrid power/ground distribution networks with multiple voltage supply in time domain. Not only this algorithm enhances common method's ability on analysis of power/ground network with irregular topology, but also very high accuracy it keeps. The accuracy and stability of this algorithm is proved using strict math method in this paper. Also, the usage of both precondition technique based on Incomplete Choleskey Decomposition and fast variable elimination technique has improved the algorithm's efficiency a lot. Experimental results show that it can finish the analysis of power/ground network with enormous size within very short time. Also, this algorithm can be applied to analyze the clock network, bus network, and signal network without buffer under high working frequency because of the independence of the topology.

  18. Voltage stability analysis considering the load dynamic characteristics and the voltage control devices; Analisis de estabilidad de voltaje considerando las caracteristicas dinamicas de la carga y dispositivos de control de voltaje

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Alvarez, Enrique

    2001-09-15

    The research work presented in this thesis, is centered in the voltage stability analysis of medium term considering the effect of the load characteristics and its interaction with the voltage control device models in the transmission network. More concretely, a type of load model is defined and studied with desirable characteristics for the study of the voltage stability, the generic load models derived from field tests and from the application of identification techniques and it is analyzed the influence of the application of control systems to improve the system stability margins. Also, alternatives to the power system modeling for the voltage stability study in complex systems are reviewed. In the first place a fundamental analysis of the voltage characteristics and stability in a simplified power system is presented and the method of adopted analysis is introduced. It is shown that the instability phenomenon is manifested as a singular type bifurcation induced from the critical way of voltage when the system is operated under stress conditions. Next, the contribution of the action of the control devices to the stability margin is analyzed and criteria of the stability analyses are deducted based on the study of such mode. Following a linear model of the power system with desirable characteristics for the study of the voltage stability of medium term is proposed and the characteristics of stability in the context of the study of complex systems are interpreted. The proposed analysis tool is based on the physical notion that the behavior of the voltage control systems in the generators is very rapid with regard to the behavior of the load and has its main application in the preliminary study of the voltage stability of medium and long term. From this model, an analytical tool based on the application of techniques of linear analysis is proposed to approach the problem of determination of critical voltage areas and the contribution of control devices to the

  19. Negligible substrate clamping effect on piezoelectric response in (111)-epitaxial tetragonal Pb(Zr, Ti)O{sub 3} films

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Tomoaki, E-mail: t-yamada@nucl.nagoya-u.ac.jp [Department of Materials, Physics and Energy Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); PRESTO, Japan Science and Technology Agency, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012 (Japan); Yasumoto, Jun; Ito, Daisuke; Yoshino, Masahito; Nagasaki, Takanori [Department of Materials, Physics and Energy Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Sakata, Osami [Synchrotron X-ray Station at SPring-8 and Synchrotron X-ray Group, National Institute for Materials Science, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Department of Innovative and Engineered Material, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Imai, Yasuhiko [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Kiguchi, Takanori [Institute for Materials Research, Tohoku University, Sendai, Miyagi 980-8577 (Japan); Shiraishi, Takahisa; Shimizu, Takao; Funakubo, Hiroshi [Department of Innovative and Engineered Material, Tokyo Institute of Technology, Yokohama 226-8503 (Japan)

    2015-08-21

    The converse piezoelectric responses of (111)- and (001)-epitaxial tetragonal Pb(Zr{sub 0.35}Ti{sub 0.65})O{sub 3} [PZT] films were compared to investigate the orientation dependence of the substrate clamping effect. Synchrotron X-ray diffraction (XRD) and piezoelectric force microscopy revealed that the as-grown (111)-PZT film has a polydomain structure with normal twin boundaries that are changed by the poling process to inclined boundaries, as predicted by Romanov et al. [Phys. Status Solidi A 172, 225 (1999)]. Time-resolved synchrotron XRD under bias voltage showed the negligible impact of substrate clamping on the piezoelectric response in the (111)-PZT film, unlike the case for (001)-PZT film. The origin of the negligible clamping effect in the (111)-PZT film is discussed from the viewpoint of the elastic properties and the compensation of lattice distortion between neighboring domains.

  20. Firing clamp: A novel method for single-trial estimation of excitatory and inhibitory synaptic neuronal conductances

    Directory of Open Access Journals (Sweden)

    Anton eChizhov

    2014-03-01

    Full Text Available Understanding non-stationary neuronal activity as seen in vivo requires estimation of both excitatory and inhibitory synaptic conductances from a single trial of recording. We propose a new intracellular recording method for this purpose called firing clamp. Synaptic conductances are estimated from the characteristics of artificially evoked probe spikes, namely the spike amplitude and the mean subthreshold potential, which are sensitive to both excitatory and inhibitory synaptic input signals. The probe spikes, timed at a fixed rate, are evoked in the dynamic-clamp mode by injected meander-like current steps, with the step duration depending on neuronal membrane voltage. We test the method with perforated-patch recordings from isolated cells stimulated by external application or synaptic release of transmitter, and validate the method with simulations of a biophysically-detailed neuron model. The results are compared with the conductance estimates based on conventional current-clamp recordings.

  1. Quantitative Analysis Linking Inner Hair Cell Voltage Changes and Postsynaptic Conductance Change: A Modelling Study

    Directory of Open Access Journals (Sweden)

    Andreas N. Prokopiou

    2015-01-01

    Full Text Available This paper presents a computational model which estimates the postsynaptic conductance change of mammalian Type I afferent peripheral process when airborne acoustic waves impact on the tympanic membrane. A model of the human auditory periphery is used to estimate the inner hair cell potential change in response to airborne sound. A generic and tunable topology of the mammalian synaptic ribbon is generated and the voltage dependence of its substructures is used to calculate discrete and probabilistic neurotransmitter vesicle release. Results suggest an almost linear relationship between increasing sound level (in dB SPL and the postsynaptic conductance for frequencies considered too high for neurons to phase lock with (i.e., a few kHz. Furthermore coordinated vesicle release is shown for up to 300–400 Hz and a mechanism of phase shifting the subharmonic content of a stimulating signal is suggested. Model outputs suggest that strong onset response and highly synchronised multivesicular release rely on compound fusion of ribbon tethered vesicles.

  2. Analysis and modeling of zero-threshold voltage native devices with industry standard BSIM6 model

    Science.gov (United States)

    Gupta, Chetan; Agarwal, Harshit; Lin, Y. K.; Ito, Akira; Hu, Chenming; Singh Chauhan, Yogesh

    2017-04-01

    In this paper, we present the modeling of zero-threshold voltage (V TH) bulk MOSFET, also called native devices, using enhanced BSIM6 model. Devices under study show abnormally high leakage current in weak inversion, leading to degraded subthreshold slope. The reasons for such abnormal behavior are identified using technology computer-aided design (TCAD) simulations. Since the zero-V TH transistors have quite low doping, the depletion layer from drain may extend upto the source (at some non-zero value of V DS) which leads to punch-through phenomenon. This source–drain leakage current adds with the main channel current, causing the unexpected current characteristics in these devices. TCAD simulations show that, as we increase the channel length (L eff) and channel doping (N SUB), the source–drain leakage due to punch-through decreases. We propose a model to capture the source–drain leakage in these devices. The model incorporates gate, drain, body biases and channel length as well as channel doping dependency too. The proposed model is validated with the measured data of production level device over various conditions of biases and channel lengths.

  3. Simulation Analysis for Opening Performance of Medium Voltage Vacuum Circuit Breaker Based on ADAMS and Maxwell

    Directory of Open Access Journals (Sweden)

    Ding Xianliang

    2017-01-01

    Full Text Available The circuit breakers play a important role in control and protect the power systemand the vacuum circuit breaker has beenwidely used in the field of medium voltage with its excellent opening performance.Virtual prototyping technology is alsobecamemore and more popularin design and optimization of the vacuum circuit breaker. In this paper, the electromagnetic simulation software Ansoft Maxwell is used to analyze the electric repulsion of the circuit breaker in the case of open the rated short circuit breaking current. The 3D model that wasbuilt by CREOis imported into ADAMS. Thenconstraints, contact force, and the electric repulsion forcethat was analysezed in Ansoft Maxwell is added into the 3D model.Therefore, we can carry on the multi-body dynamics simulation to the 3D model. Then We can get the openingperformance of the vacuum circuit breakerin the condition of open circuit rated short circuit breaking current. The simulation results show that the circuit breaker can still meet the performance requirements in the condition of open circuit rated short circuit breaking current.

  4. Design-Oriented Analysis of Resonance Damping and Harmonic Compensation for LCL-Filtered Voltage Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    This paper addresses the interaction between harmonic resonant controllers and active damping of LCL resonance in voltage source converters. A virtual series R-C damper in parallel with the filter capacitor is proposed with the capacitor current feedback loop. The phase lag resulting from the dig...... crossover frequency defined by the proportional gain of current controller. This is of particular interest for high-performance active harmonic filtering applications and low-pulse-ratio converters. Case studies in experiments validate the theoretical analysis.......This paper addresses the interaction between harmonic resonant controllers and active damping of LCL resonance in voltage source converters. A virtual series R-C damper in parallel with the filter capacitor is proposed with the capacitor current feedback loop. The phase lag resulting from...... the digital computation and modulation delays is thus compensated by the virtual capacitor. The frequency region that allows using resonant controllers is then identified with the virtual damper. It reveals that the upper frequency limit of harmonic resonant controllers can be increased above the gain...

  5. ANALYSIS VOLTAGE STABILITY USING HOPF BIFURCATION THEORY%电压稳定中的Hopf分歧分析

    Institute of Scientific and Technical Information of China (English)

    王洪哲; 邓集祥

    2000-01-01

    本文采用Hopf分歧理论结合相关因子法研究探讨电压稳定性问题,Hopf分歧理论比较全面地考虑系统的非线性性态,能够比传统的分析方法更深刻地探讨电力系统在临界点附近的稳定问题,并且能够在一定程度上将功角稳定问题和电压稳定问题联系起来提供统一的数学分析基础。%The combination of the bifurcation theory and relevant factortheory is proposed to search and discuss the voltage stability in this paper. Hopf bifurcation theory can more comprehensively reveal the nonlinear character of the system ,so it can more deeply search and discuss the stability nearby the critical point than the traditional analyzing method. To the extent,it can connect the P-δ stability with the voltage stability and provide the general mathematics analysis foundation.

  6. State-of-the-art automated patch clamp devices: Heat activation, action potentials and high throughput in ion channel screening

    Directory of Open Access Journals (Sweden)

    Sonja eStoelzle

    2011-11-01

    Full Text Available Ion channels are essential in a wide range of cellular functions and their malfunction underlies many disease states making them important targets in drug discovery. Diverse automated patch clamp systems with high-throughput capabilities are available for drug screening, but there are limitations in the application range. For example, solution exchange time, temperature control and the availability of the current clamp mode can be limiting factors. However, further development of existing devices and introduction of new systems widen the range of possible experiments and increase throughput. Here we introduce new features and platforms that meet the needs of drug discovery researchers and basic researchers alike.The Patchliner is an automated patch clamp system capable of recording up to 8 cells simultaneously with high success rates. Novel features such as temperature control and recordings in the current clamp mode are described here. Standard cell lines and excitable cells such as stem cell-derived cardiomyocytes have been used in the voltage clamp and current clamp modes with the view to finding new drug candidates and safety testing methods in a more physiologically relevant environment. The SyncroPatch 96, is a screening platform capable of recording from 96 cells in parallel and offers a throughput of 5000 data points per day. Full dose response curves can be acquired from individual cells reducing the cost per data point. The system is an ideal tool for secondary screening efforts and for safety testing on ligand- and voltage-gated ion channels.The Patchliner and SyncroPatch 96 are ideal platforms for drug discovery, ion channel research and safety testing, combining long awaited features such as parallel action potential recordings and temperature control with extensively increased throughput.

  7. Direct Torque Control for Three-Level Neutral Point Clamped Inverter-Fed Induction Motor Drive

    Directory of Open Access Journals (Sweden)

    M. K. Sahu

    2012-04-01

    Full Text Available Direct torque control (DTC is a control technique in AC drive systems to obtain high performance torque control. The classical DTC drive contains a pair of hysteresis comparators and suffers from variable switching frequency and high torque ripple. These problems can be solved by using space vector depending on the reference torque and flux. In this paper the space vector modulation technique is applied to the three-level Neutral Point Clamped (NPC inverter control in the proposed DTC-based induction motor drive system, resulting to a significant reduce of torque ripple. Three-level neutral point clamped inverters have been widely used in medium voltage applications. This type of inverters have several advantages over standard two-level VSI, such as greater number of levels in the output voltage waveforms, less harmonic distortion in voltage and current waveforms and lower switching frequencies. This paper emphasizes the derivation of switching states using the Space Vector Pulse Width Modulation (SVPWM technique. The control scheme is implemented using Matlab/Simulink. Experimental results using dSPACE validate the steady-state and the dynamic performance of the proposed control strategy.

  8. Testing of Diode-Clamping in an Inductive Pulsed Plasma Thruster Circuit

    Science.gov (United States)

    Toftul, Alexandra; Polzin, Kurt A.; Martin, Adam K.; Hudgins, Jerry L.

    2014-01-01

    Testing of a 5.5 kV silicon (Si) diode and 5.8 kV prototype silicon carbide (SiC) diode in an inductive pulsed plasma thruster (IPPT) circuit was performed to obtain a comparison of the resulting circuit recapture efficiency,eta(sub r), defined as the percentage of the initial charge energy remaining on the capacitor bank after the diode interrupts the current. The diode was placed in a pulsed circuit in series with a silicon controlled rectifier (SCR) switch, and the voltages across different components and current waveforms were collected over a range of capacitor charge voltages. Reverse recovery parameters, including turn-off time and peak reverse recovery current, were measured and capacitor voltage waveforms were used to determine the recapture efficiency for each case. The Si fast recovery diode in the circuit was shown to yield a recapture efficiency of up to 20% for the conditions tested, while the SiC diode further increased recapture efficiency to nearly 30%. The data presented show that fast recovery diodes operate on a timescale that permits them to clamp the discharge quickly after the first half cycle, supporting the idea that diode-clamping in IPPT circuit reduces energy dissipation that occurs after the first half cycle

  9. Optimization of a clamped plate silencer.

    Science.gov (United States)

    Wang, Chunqi; Han, Jun; Huang, Lixi

    2007-02-01

    A previous theoretical study [L. Huang, J. Acoust. Soc. Am. 119, 2628-2638 (2006)] shows that, in a duct, a simply supported plate covering a side-branch rigid cavity can function effectively as a wave reflector over a broad range of low to medium frequencies. In this study, analytical formulation is extended to the boundary condition of clamped plate, which is easier to implement in practice. The theoretical model is tested experimentally using balsawood, which has a very high stiffness to mass ratio. The spectral peaks and shapes of the measured TL are in agreement with those calculated theoretically, attempts are also made to account for the considerable sound absorption in the rig. Further numerical studies based on the validated model show that, for a uniform plate, the optimal stopband is narrower and the lower band limit is worse than that of the simply supported configuration. However, a wave reflector using nonuniform, clamped plates with thinner ends out-performs the simply supported configuration in every aspect. Analyses show that the improvement is attributed to the increased acoustic radiation efficiency over the bulk length of the nonuniform plate, which behaves more like a rigid plate.

  10. Development of voltage-dependent calcium, sodium, and potassium currents in Xenopus spinal neurons.

    Science.gov (United States)

    O'Dowd, D K; Ribera, A B; Spitzer, N C

    1988-03-01

    Action potentials of embryonic nerve and muscle cells often have a different ionic dependence and longer duration than those of mature cells. The action potential of spinal cord neurons from Xenopus laevis exhibits a prominent calcium component at early stages of development that diminishes with age as the impulse becomes principally sodium dependent. Whole-cell voltage-clamp analysis has been undertaken to characterize the changes in membrane currents during development of these neurons in culture. Four voltage-dependent currents of cells were identified and examined during the first day in vitro, when most of the change in the action potential occurs. There are no changes in the peak density of the calcium current (ICa), its voltage dependence, or time to half-maximal activation; a small increase in inactivation is apparent. The major change in sodium current (INa) is a 2-fold increase in its density. In addition, more subtle changes in the kinetics of the macroscopic sodium current were noted. The peak density of voltage-dependent potassium current (IKv) increases 3-fold, and this current becomes activated almost twice as fast. No changes were noted in the extent of its inactivation. The calcium-dependent potassium current (IKc) consists of an inactivating and a sustained component. The former increases 2-fold in peak current density, and the latter increases similarly at less depolarized voltages. The changes in these currents contribute to the decrease in duration and the change in ionic dependence of the impulse.

  11. Characterization of voltage-gated ionic currents in a peripheral sensory neuron in larval Drosophila

    Directory of Open Access Journals (Sweden)

    Bate Michael

    2010-06-01

    Full Text Available Abstract Background The development, morphology and genetics of sensory neurons have been extensively studied in Drosophila. Sensory neurons in the body wall of larval Drosophila in particular have been the subject of numerous anatomical studies, however, little is known about the intrinsic electrical properties of larval sensory cells. Findings We performed whole cell patch recordings from an identified peripheral sensory cell, the dorsal bipolar sensory neuron (dbd and measured voltage-gated ionic currents in 1st instar larvae. Voltage clamp analysis revealed that dbds have a TEA sensitive, non-inactivating IK type potassium current as well as a 4-AP sensitive, inactivating IA type potassium current. dbds also show a voltage-gated calcium current (ICa and a voltage-gated sodium current (INa. Conclusions This work provides a first characterization of voltage-activated ionic currents in an identified body-wall sensory neuron in larval Drosophila. Overall, we establish baseline physiology data for future studies aimed at understanding the ionic and genetic basis of sensory neuron function in fruit flies and other model organisms.

  12. The application of the Escherichia coli giant spheroplast for drug screening with automated planar patch clamp system

    Directory of Open Access Journals (Sweden)

    Kyoko Kikuchi

    2015-09-01

    Full Text Available Kv2.1, the voltage-gated ion channel, is ubiquitously expressed in variety of tissues and dysfunction of this ion channel is responsible for multiple diseases. Electrophysiological properties of ion channels are so far characterized with eukaryotic cells using the manual patch clamp which requires skilful operators and expensive equipments. In this research, we created a simple and sensitive drug screen method using bacterial giant spheroplasts and the automated patch clamp which does not require special skills. We expressed a eukaryotic voltage-gated ion channel Kv2.1 in Escherichia coli using prokaryotic codon, and prepared giant spheroplasts large enough for the patch clamp. Human Kv2.1 currents were successfully recorded from giant spheroplasts with the automated system, and Kv2.1-expressed E. coli spheroplasts could steadily reacted to the dose–response assay with TEA and 4-AP. Collectively, our results indicate for the first time that the bacterial giant spheroplast can be applied for practical pharmaceutical assay using the automated patch clamp.

  13. Characterization and functional analysis of voltage-dependent anion channel 1 (VDAC1) from orange-spotted grouper (Epinephelus coioides).

    Science.gov (United States)

    Shi, Yan; Zhao, Zhe; Hong, Xiaoyou; Chen, Kunci; Zhu, Xinping

    2014-07-01

    The voltage-dependent anion channel (VDAC) is a highly conserved integral protein of mitochondria in different eukaryotic species. It forms a selective channel in the mitochondrial outer membrane that serves as the controlled pathway for small metabolites and ions. In this study, a VDAC gene, EcVDAC1, was isolated from orange-spotted grouper (Epinephelus coioides). The EcVDAC1 exhibits ubiquitous expression in various tissues of orange-spotted grouper and is upregulated in liver, gill, and spleen after stimulation with lipopolysaccharides (LPS). Subcellular localization analysis shows that the EcVDAC1 protein colocalized with the mitochondria. A caspase-3 assay demonstrates that overexpression of the EcVDAC1 induced apoptotic cell death in fathead minnow cells. The data presented in this study provide new information regarding the relationship between LPS and the EcVDAC1 gene, suggesting that the fish VDAC1 gene may play an important role in antibacterial immune response.

  14. Analysis and design of a high-efficiency zero-voltage-switching step-up DC–DC converter

    Indian Academy of Sciences (India)

    Jae-Won Yang; Hyun-Lark Do

    2013-08-01

    A high-efficiency zero-voltage-switching (ZVS) step-up DC–DC converter is proposed. The proposed ZVS DC–DC step-up converter has fixed switching frequency, simple control, and high efficiency. All power switches can operate with ZVS. The output diodes are under zero-current-switching (ZCS) during turn-off. Due to soft-switching operation of the power switches and output diodes, the proposed ZVS DC–DC converter shows high efficiency. Steady-state analysis of the converter is presented to determine the circuit parameters. A laboratory prototype of the proposed converter is developed, and its experimental results are presented for validation.

  15. Fault identification in crystalline silicon PV modules by complementary analysis of the light and dark current-voltage characteristics

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Sera, Dezso; Hacke, Peter

    2016-01-01

    (soiling, shading, discoloration). The premise of the method that is proposed is that different degradation modes affect the light and dark I-V characteristics of the PV module in different ways, leaving distinct signatures. This work focuses on identifying and correlating these specific signatures present......This article proposes a fault identification method, based on the complementary analysis of the light and dark current-voltage (I-V) characteristics of the photovoltaic (PV) module, to distinguish between four important degradation modes that lead to power loss in PV modules: (a) degradation...... in the light and dark I-V measurements, to specific degradation modes; a number of new dark I-V diagnostic parameters are proposed to quantify these signatures. The experimental results show that these dark I-V diagnostic parameters, complemented by light I-V performance and series resistance measurements can...

  16. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.;

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence...... windings thus preventing the core from saturation; lowers the voltage stresses and power losses of inverter switches and reduces the sizes of filtering devices and as well as obtains better output performance compared to the original two-level Z-source inverters. A phase disposition pulse width modulation...

  17. Effect of La3+ on myocardiac potassium channels revealed by patch-clamp technique

    Institute of Scientific and Technical Information of China (English)

    XUE Shaowu; YANG Pin

    2005-01-01

    The effect of La3+ on potassium channels in rat ventricular myocytes was investigated using the whole-cell patch-clamp recording mode. The Ca2+-independent voltage- activated outward K+ current was activated by the depolarizing pulse in enzymatically isolated rat ventricular myocytes. After addition of different concentrations La3+ to the bath solution, the outward K+ current was depressed gradually. The inhibition effect was in a concentration-dependent manner. The phenomena of the outward K+ current, being the main repolarizing current suppressed by La3+, suggest that the effect of lanthanides on myocardial function should be exploited further.

  18. Comparative Evaluation of Modeling Methods for Harmonic Stability Analysis of Three-Phase Voltage Source Converters

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth;

    2015-01-01

    As the increasing of power electronics based systems, not only the component-based analysis but also a systematic interaction analysis with each other systems are being important. Especially studies about the stability and the harmonics interaction are critical in order to establish the required ...

  19. Neutral-point voltage dynamic model of three-level NPC inverter for reactive load

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, Sergio

    2012-01-01

    A three-level neutral-point-clamped inverter needs a controller for the neutral-point voltage. Typically, the controller design is based on a dynamic model. The dynamic model of the neutral-point voltage depends on the pulse width modulation technique used for the inverter. A pulse width modulati...

  20. Kinetics properties of voltage induced colicin Ia channels into a lipid bilayer

    CERN Document Server

    Cassia-Moura, R

    1998-01-01

    The activation kinetics of the ion channels formed by colicin Ia incorporated into a planar bilayer lipid membrane (BLM) was investigated by the voltage clamp technique using different step voltage stimuli. The temporal behaviour of ion channels put in evidence a gain or a loss of memory, revealed by a specific sequence of electrical pulses used for stimulation.

  1. Development of modulation strategies for NPC converter addressing DC link voltage balancing and CMV reduction

    DEFF Research Database (Denmark)

    Boian, D.; Biris, C.; Teodorescu, Remus

    2012-01-01

    in insulation breakdown and bearing failures. By the use of this type of converters, both Electromagnetic Interference (EMI) and harmonic distortions are improved. This paper proposes two modulation strategies for Three Level Neutral Point Clamped Converter (3L-NPC). The main focus of these modulation...... strategies is to reduce the Common Mode Voltage (CMV) and balance the DC Link Voltage....

  2. PI and Fuzzy Control Strategies for High Voltage Output DC-DC Boost Power Converter - Hardware Implementation and Analysis

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Siano, Pierluigi

    2016-01-01

    converter with inbuilt voltage-lift technique and overcome the aforementioned deficiencies. Further, the control strategy is adapted based on proportional-integral (P-I) and fuzzy logic, closed-loop controller to regulate the outputs and ensure the performances. Complete hardware prototype of EHV converter......This paper presents the control strategies by Proportional-Integral (P-I) and Fuzzy Logic (FL) for a DC-DC boost power converter for high output voltage configuration. Standard DC-DC converters are traditionally used for high voltage direct current (HVDC) power transmission systems. But, lack its...... performances in terms of efficiency, reduced transfer gain and increased cost with sensor units. Moreover, the internal self-parasitic components reduce the output voltage and efficiency of classical high voltage converters (HVC). This investigation focused on extra high-voltage (EHV) DC-DC boost power...

  3. Pulsewidth-modulated 2-source neutral-point-clamped inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chang; Gao, Feng;

    2007-01-01

    -shaped inductance-capacitance (LC) impedance networks that are connected between two isolated dc input power sources and its inverter circuitry for boosting its AC output voltage. Through the design of an appropriate pulsewidth-modulation (PWM) algorithm, the two impedance networks can be short-circuited...... algorithm and by short-circuiting the two impedance networks simultaneously, the designed NPC inverter, with no requirement for deadtime delay, can also be operated with a completely eliminated common-mode voltage. Implementation wise, a detailed vectorial analysis interestingly shows that the same generic...

  4. Obstetricians' attitudes and beliefs regarding umbilical cord clamping.

    Science.gov (United States)

    Jelin, Angie C; Kuppermann, Miriam; Erickson, Kristine; Clyman, Ronald; Schulkin, Jay

    2014-09-01

    Although delayed umbilical cord clamping has been demonstrated to reduce the incidence of intraventricular hemorrhage and neonatal sepsis, and decrease the need for neonatal transfusions (without affecting cord pH, Apgar scores or the need for phototherapy), the extent to which this practice is being employed is unknown. We conducted a survey of US obstetricians to assess their attitudes and beliefs about cord clamping. Questionnaires were randomly mailed to members of the American College of Obstetricians and Gynecologists (ACOG), and the Collaborative Ambulatory Research Network (CARN). The data were analyzed using Chi-square and Student t tests. The response rates for the CARN and other ACOG members were 47% and 21%, respectively. Most (88%) responders reported their hospital had no umbilical cord clamping policy. The most frequent response for optimal timing of umbilical cord clamping, regardless of gestational age, was "don't know". Potential for neonatal red blood cell transfusion was the only concern cited as a reason for being somewhat or very inclined to delay umbilical cord clamping (51%). Delayed neonatal resuscitation (76%) was listed as a reason to clamp the cord immediately, despite the paucity of literature to support immediate cord clamping in this cohort. Despite substantial evidence supporting the practice of delayed cord clamping, few institutions have policies regarding this practice. Moreover, obstetricians' beliefs about the appropriate timing for umbilical cord clamping are not consistent with the evidence that demonstrates its beneficial impact on neonatal outcomes.

  5. Dynamic Characteristic Analysis of Linear DC Motor by 3D EMCN Considering Input Voltage

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Kyung Ho; Yeom, Sang Bu [Changwon National University, Changwon(Korea); Hong, JUNG Pyo; Hur Jin; Kang Do Hyunc [Hanyang University(Seoul Campus), Seoul(Korea)

    2002-02-01

    In order to design the Linear DC Motor (LDM) With improved characteristics, transient and steady state analysis are required. Furthermore, 3D analysis is also needed to analyze the precise characteristics like thrust, time harmonics. This paper deals with the transient and dynamic characteristic analysis if LDM by coupling of external circuit and motion equation using 3D Equivalent Magnetic Circuit Network Method (EMCN). For the three dimensional analysis of electric machine, EMCN is very effective method that ensures high accuracy similar to FEM and short computation time. Also, The modeling by EMCN easily allows the mover to move with respect to the Sartre at each time Also, and the spatial moving step is determined by the solution of the mechanical motion equation and the computed electromagnetic thrust. The results are compared with experimental ones to clarify the usefulness and verify the accuracy of the proposed method. (author). 11 refs., 20 figs., 2 tabs.

  6. Two distinct voltage-sensing domains control voltage sensitivity and kinetics of current activation in CaV1.1 calcium channels.

    Science.gov (United States)

    Tuluc, Petronel; Benedetti, Bruno; Coste de Bagneaux, Pierre; Grabner, Manfred; Flucher, Bernhard E

    2016-06-01

    Alternative splicing of the skeletal muscle CaV1.1 voltage-gated calcium channel gives rise to two channel variants with very different gating properties. The currents of both channels activate slowly; however, insertion of exon 29 in the adult splice variant CaV1.1a causes an ∼30-mV right shift in the voltage dependence of activation. Existing evidence suggests that the S3-S4 linker in repeat IV (containing exon 29) regulates voltage sensitivity in this voltage-sensing domain (VSD) by modulating interactions between the adjacent transmembrane segments IVS3 and IVS4. However, activation kinetics are thought to be determined by corresponding structures in repeat I. Here, we use patch-clamp analysis of dysgenic (CaV1.1 null) myotubes reconstituted with CaV1.1 mutants and chimeras to identify the specific roles of these regions in regulating channel gating properties. Using site-directed mutagenesis, we demonstrate that the structure and/or hydrophobicity of the IVS3-S4 linker is critical for regulating voltage sensitivity in the IV VSD, but by itself cannot modulate voltage sensitivity in the I VSD. Swapping sequence domains between the I and the IV VSDs reveals that IVS4 plus the IVS3-S4 linker is sufficient to confer CaV1.1a-like voltage dependence to the I VSD and that the IS3-S4 linker plus IS4 is sufficient to transfer CaV1.1e-like voltage dependence to the IV VSD. Any mismatch of transmembrane helices S3 and S4 from the I and IV VSDs causes a right shift of voltage sensitivity, indicating that regulation of voltage sensitivity by the IVS3-S4 linker requires specific interaction of IVS4 with its corresponding IVS3 segment. In contrast, slow current kinetics are perturbed by any heterologous sequences inserted into the I VSD and cannot be transferred by moving VSD I sequences to VSD IV. Thus, CaV1.1 calcium channels are organized in a modular manner, and control of voltage sensitivity and activation kinetics is accomplished by specific molecular mechanisms

  7. FUNDAMENTAL RESONANCE AND BIFURCATION OF LARGE GENERATOR END WINDING WHEN ITS CLAMPING PLATES ARE LOOSE

    Institute of Scientific and Technical Information of China (English)

    HU Yu-da; QIU Jia-jun; TA Na

    2005-01-01

    Vibration problems of a segment of winding between two clamping plates are studied when the clamping plates, which are used to fix stator end winding, are loose. First,magnetic induction expressions of the winding while the generator was running were given by using separation of variables method. Also, the expressions of the winding electromagnetic force and dry friction force between loosing clamping plates were gotten. Secondly, a mechanical model, which was used to study nonlinear vibration problem of the winding, was set up. Fundamental resonance was analyzed by using multiple scales method, and a resonance equation of amplitude and frequency in steady state was given. Then stability,bifurcation and singularity of the steady solution were studied. Criterions of stability and transition set of the bifurcation equation were obtained. At last, through numerical calculations, resonance curves were obtained. The results are helpful for analysis and protection of generator accidents.

  8. Thermal stiffening of clamped elastic ribbons

    Science.gov (United States)

    Wan, Duanduan; Nelson, David R.; Bowick, Mark J.

    2017-07-01

    We use molecular dynamics to study the vibrations of a thermally fluctuating two-dimensional elastic membrane clamped at both ends. We directly extract the eigenmodes from resonant peaks in the frequency domain of the time-dependent height and measure the dependence of the corresponding eigenfrequencies on the microscopic bending rigidity of the membrane, taking care also of the subtle role of thermal contraction in generating a tension when the projected area is fixed. At finite temperatures we show that the effective (macroscopic) bending rigidity tends to a constant as the bare bending rigidity vanishes, consistent with theoretical arguments that the large-scale bending rigidity of the membrane arises from a strong thermal renormalization of the microscopic bending rigidity. Experimental realizations include covalently bonded two-dimensional atomically thin membranes such as graphene and molybdenum disulfide or soft matter systems such as the spectrin skeleton of red blood cells or diblock copolymers.

  9. Experimental Analysis of Linear Induction Motor under Variable Voltage Variable Frequency (VVVF Power Supply

    Directory of Open Access Journals (Sweden)

    Prasenjit D. Wakode

    2016-07-01

    Full Text Available This paper presents the complete analysis of Linear Induction Motor (LIM under VVVF. The complete variation of LIM air gap flux under ‘blocked Linor’ condition and starting force is analyzed and presented when LIM is given VVVF supply. The analysis of this data is important in further understanding of the equivalent circuit parameters of LIM and to study the magnetic circuit of LIM. The variation of these parameters is important to know the LIM response at different frequencies. The simulation and application of different control strategies such as vector control thus becomes quite easy to apply and understand motor’s response under such strategy of control.

  10. Accurate Switched-Voltage voltage averaging circuit

    OpenAIRE

    金光, 一幸; 松本, 寛樹

    2006-01-01

    Abstract ###This paper proposes an accurate Switched-Voltage (SV) voltage averaging circuit. It is presented ###to compensated for NMOS missmatch error at MOS differential type voltage averaging circuit. ###The proposed circuit consists of a voltage averaging and a SV sample/hold (S/H) circuit. It can ###operate using nonoverlapping three phase clocks. Performance of this circuit is verified by PSpice ###simulations.

  11. Vestibular integrator neurons have quadratic functions due to voltage dependent conductances.

    Science.gov (United States)

    Magnani, Christophe; Eugène, Daniel; Idoux, Erwin; Moore, Lee E

    2013-12-01

    The nonlinear properties of the dendrites of the prepositus hypoglossi nucleus (PHN) neurons are essential for the operation of the vestibular neural integrator that converts a head velocity signal to one that controls eye position. A novel system of frequency probing, namely quadratic sinusoidal analysis (QSA), was used to decode the intrinsic nonlinear behavior of these neurons under voltage clamp conditions. Voltage clamp currents were measured at harmonic and interactive frequencies using specific nonoverlapping stimulation frequencies. Eigenanalysis of the QSA matrix reduces it to a remarkably compact processing unit, composed of just one or two dominant components (eigenvalues). The QSA matrix of rat PHN neurons provides signatures of the voltage dependent conductances for their particular dendritic and somatic distributions. An important part of the nonlinear response is due to the persistent sodium conductance (gNaP), which is likely to be essential for sustained effects needed for a neural integrator. It was found that responses in the range of 10 mV peak to peak could be well described by quadratic nonlinearities suggesting that effects of higher degree nonlinearities would add only marginal improvement. Therefore, the quadratic response is likely to sufficiently capture most of the nonlinear behavior of neuronal systems except for extremely large synaptic inputs. Thus, neurons have two distinct linear and quadratic functions, which shows that piecewise linear + quadratic analysis is much more complete than just piecewise linear analysis; in addition quadratic analysis can be done at a single holding potential. Furthermore, the nonlinear neuronal responses contain more frequencies over a wider frequency band than the input signal. As a consequence, they convert limited amplitude and bandwidth input signals to wider bandwidth and more complex output responses. Finally, simulations at subthreshold membrane potentials with realistic PHN neuron models

  12. High voltage load resistor array

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  13. Fast neutron activation analysis by means of low voltage neutron generator

    Science.gov (United States)

    Medhat, M. E.

    A description of D-T neutron generator (NG) is presented. This machine can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. Procedure of neutron flux determination and efficiency calculation is described. Examples of testing some Egyptian natural cosmetics are given.

  14. Optimization Analysis for Hybrid-drive Clamping Unit of All-electric Injection Molding Machine%全电动注塑机混合驱动式合模机构优化分析

    Institute of Scientific and Technical Information of China (English)

    边旭东; 伍先安; 谢鹏程; 丁玉梅; 杨卫民

    2012-01-01

    For the purpose of speeding up the velocity of shifting mode of all-electric injection molding machine and optimizing the velocity curve of moving template, a new type of hybrid-driven toggle mechanism was designed and optimized, kinematics simulation and dynamic simulation of this new toggle mechanism were made in this paper. The results showed that, compared to the existing all-electric hybrid-driven clamping u-nit, the velocity of shifting mode of new hybrid-driven clamping unit had significantly improved, the velocity curve of moving template was also closer to the ideal sine curve. The new toggle mechanism of all-electric hy-brid-driven precision injection molding machine had the advantage of low cost, while the performance of kine-matics and dynamics exceeded the existing all-electric hybrid-driven clamping structure.%以加快合模机构移模速度和优化移模速度曲线为目的,优化设计出一种新型混合驱动式合模机构,并对该合模机构的开合模过程进行运动学仿真和动力学仿真.结果表明,相比于现有全电动注塑机混合驱动合模机构,新型混合驱动式合模结构在移模速度上有了显著提高,移模速度曲线也更接近理想的正弦曲线.新型全电动精密注塑机混合驱动合模结构具有低成本化的优势,同时其机构运动学和动力学的性能也超越了已有全电动混合驱动合模结构.

  15. Analysis of capacitive effect and life estimation of hydrodynamic journal bearings on repeated starts and stops of a machine operating under the influence of shaft voltages

    Science.gov (United States)

    Prashad, Har; Rao, K. N.

    1994-07-01

    A theoretical analysis has been carried out to study the capacitive effect and life estimation of hydrodynamic journal bearings on repeated starts and stops of a machine operating under the influence of shaft voltages. The analysis gives the time required for the charge accumulation and increase of charge with time on the liner surface of a journal bearing based on bearing capacitance, resistance of film thickness, and the shaft voltage. Also, it investigates the effect of gradual leakage of the accumulated charges with time as the shaft voltage falls when the power supply to the machine is switched off. This paper gives an approach to determine the ratio of the number of shaft revolutions required for charge accumulation and gradual discharge of the accumulated charges on the liner surface of a bearing depending on bearing-to-shaft voltage. Also, the number of repeated starts and stops before initiation of craters on the liner surface of a hydrodynamic journal bearing is established to restrict deterioration and damage of the liner. The diagnosis has the potential to study the transient effect of the shaft voltages on a journal bearing during the start and stop cycle of a machine.

  16. Analysis and simulation of the three-phase AC voltage regulation circuit%三相交流调压电路的分析与仿真

    Institute of Scientific and Technical Information of China (English)

    李衍孜

    2012-01-01

    Based on the analysis of the operation principle and mode of the single-phase AC voltage-regulation circuit, the voltage-regulating rule and effect of three-phase AC voltage-regulation was studied deeply in the paper. The theory of the three-phase star-style AC voltage-regulation circuit was tested in matlab/simulink, the simulation result proved the analysis of the theory of the three-phase AC voltage-regulation circuit was correct.%在分析单相交流调压电路运行原理和工作方式的基础上,深入研究了三相交流调压电路的调压规律和调压效果,并在Matlab/simulink仿真平台上对三相星形无中线交流调压电路的理论部分进行了验证,结果表明:三相交流调压电路的分析是正确的.

  17. Pulse-Width-Modulation of Neutral-Point-Clamped Sparse Matrix Converter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Gao, F.

    2007-01-01

    literature. Addressing the afore-described issues, this paper focuses on the operational mode analysis of a three-level sparse matrix converter implemented using a neutral-point-clamped inversion stage, and  the design of a number of PWM and modulation ratio compensation schemes for controlling the converter...

  18. The PCNA-RFC families of DNA clamps and clamp loaders.

    Science.gov (United States)

    Majka, Jerzy; Burgers, Peter M J

    2004-01-01

    The proliferating cell nuclear antigen PCNA functions at multiple levels in directing DNA metabolic pathways. Unbound to DNA, PCNA promotes localization of replication factors with a consensus PCNA-binding domain to replication factories. When bound to DNA, PCNA organizes various proteins involved in DNA replication, DNA repair, DNA modification, and chromatin modeling. Its modification by ubiquitin directs the cellular response to DNA damage. The ring-like PCNA homotrimer encircles double-stranded DNA and slides spontaneously across it. Loading of PCNA onto DNA at template-primer junctions is performed in an ATP-dependent process by replication factor C (RFC), a heteropentameric AAA+ protein complex consisting of the Rfc1, Rfc2, Rfc3, Rfc4, and Rfc5 subunits. Loading of yeast PCNA (POL30) is mechanistically distinct from analogous processes in E. coli (beta subunit by the gamma complex) and bacteriophage T4 (gp45 by gp44/62). Multiple stepwise ATP-binding events to RFC are required to load PCNA onto primed DNA. This stepwise mechanism should permit editing of this process at individual steps and allow for divergence of the default process into more specialized modes. Indeed, alternative RFC complexes consisting of the small RFC subunits together with an alternative Rfc1-like subunit have been identified. A complex required for the DNA damage checkpoint contains the Rad24 subunit, a complex required for sister chromatid cohesion contains the Ctf18 subunit, and a complex that aids in genome stability contains the Elg1 subunit. Only the RFC-Rad24 complex has a known associated clamp, a heterotrimeric complex consisting of Rad17, Mec3, and Ddc1. The other putative clamp loaders could either act on clamps yet to be identified or act on the two known clamps.

  19. An Analysis of Magnetic Field Environment Near High-Voltage Power Lines and Contact Wires of Electric Railways

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Image method is used in this paper to calculate the value of magnetic field near high-voltage transmission lines and electric railways. Areas in which the magnetic field is less than 0.002 Gauss are given and the magnetic pollution of high-voltage power transmission lines and electric railways is discussed

  20. A comprehensive analysis and hardware implementation of control strategies for high output voltage DC-DC boost power converter

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevikumar; Grandi, Gabriele; Blaabjerg, Frede

    2017-01-01

    Classical DC-DC converters used in high voltage direct current (HVDC) power transmission systems, lack in terms of efficiency, reduced transfer gain and increased cost with sensor (voltage/current) numbers. Besides, the internal self-parasitic behavior of the power components reduces the output v...

  1. Analysis of cutting-edge techniques in the high voltage and high power adjustable speed drive systems

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The high voltage and high power adjustable speed drive (ASD) system is one of the most attractive fields in power electronics, and it is also a very crucial technique for energy saving and emission reduction. This paper discussed and analyzed the main cutting-edge knowledge and issues in the process of exploiting the high voltage and high power ASD system.

  2. Cholesterol favors the emergence of a long-range autocorrelated fluctuation pattern in voltage-induced ionic currents through lipid bilayers.

    Science.gov (United States)

    Corvalán, Natalia A; Kembro, Jackelyn M; Clop, Pedro D; Perillo, María A

    2013-08-01

    The present paper was aimed at evaluating the effect of cholesterol (CHO) on the voltage-induced lipid pore formation in bilayer membranes through a global characterization of the temporal dynamics of the fluctuation pattern of ion currents. The bilayer model used was black lipid membranes (BLMs) of palmitoyloleoylphosphatidylethanolamine and palmitoyloleoylphosphatidylcholine (POPE:POPC) at a 7:3 molar ratio in the absence (BLM0) or in the presence of 30 (BLM30), 40 (BLM40) or 50(BLM50)mol% of cholesterol with respect to total phospholipids. Electrical current intensities (I) were measured in voltage (ΔV) clamped conditions at ΔV ranging between 0 and ±200mV. The autocorrelation parameter α derived from detrended fluctuation analysis (DFA) on temporal fluctuation patterns of electrical currents allowed discriminating between non-correlated (α=0.5, white noise) and long-range correlated (0.5number of conductance states, the magnitude of conductance level, the capacitance of the bilayers and increased the tendency towards the development of long-range autocorrelated (fractal) processes (0.5<α<1) in lipid channel generation. Experiments were performed above the phase transition temperature of the lipid mixtures, but compositions used predicted a superlattice-like organization. This leads to the conclusion that structural defects other than phase coexistence may promote lipid channel formation under voltage clamped conditions. Furthermore, cholesterol controls the voltage threshold that allows the percolation of channel behavior where isolated channels become an interconnected network.

  3. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    DEFF Research Database (Denmark)

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis...

  4. Multi-mode excitation of a clamped–clamped microbeam resonator

    KAUST Repository

    Younis, Mohammad I.

    2015-02-18

    We present modeling and simulation of the nonlinear dynamics of a microresonator subjected to two-source electrostatic excitation. The resonator is composed of a clamped–clamped beam excited by a DC voltage load superimposed to two AC voltage loads of different frequencies. One frequency is tuned close to the first natural frequency of the beam and the other is close to the third (second symmetric) natural frequency. A multi-mode Galerkin procedure is applied to extract a reduced-order model, which forms the basis of the numerical simulations. Time history response, Poincare’ sections, Fast Fourier Transforms FFT, and bifurcation diagrams are used to reveal the dynamics of the system. The results indicate complex nonlinear phenomena, which include quasiperiodic motion, torus bifurcations, and modulated chaotic attractors.

  5. A DTC Algorithm for Induction Motor Drives with 3-level Diode-Clamped Inverters

    Directory of Open Access Journals (Sweden)

    M. Cirrincione

    2005-12-01

    Full Text Available This paper presents a novel Direct Torque Control (DTC algorithm for induction motor electrical drives supplied by 3-level diode clamped inverters. It is the natural extension of the classic Switching Table (ST based DTC, modified for a 3-level inverter supply. It presents also a very simple algorithm for the minimization of the capacitor voltage ripple. Results obtained with numerical simulations show that the employment of a 3-level inverter in such a control scheme permits to obtain the same dynamical performances as those obtained with a 2-level inverter with resulting lower torque and flux ripples as well as a lower harmonic content in the stator voltages and currents. Some considerations about the consequent benefits as for EMC of this drive are also presented.

  6. Fault Analysis of DC Voltage Dividers in Xiangjiaba--Shanghai ±800 kV UHVDC Project

    Institute of Scientific and Technical Information of China (English)

    LI Fengqi; SHE Zhengqiu; LOU Dianqiang; Rajendra Iyer; Urban Astrom

    2012-01-01

    Transient DC voltage measurement error has been observed several times ever since Xiangjiaba--Shanghai ±800 kV UHVDC project started its commercial operation. The measurement error causes considerable disturbances to the AC networks. By analyzing the time frequency record, simulating faults at different positions of the divider, and testing the gas in voltage dividers, the fault is located and then is proved to be some partial discharges inside DC voltage dividers. The reason of the internal flashes and the solution to the problem is also discussed in this paper. The conclusion is that instead of N2 , SF6 should be used for the internal insulation of high voltage DC voltage dividers.

  7. Loading Analysis of Modular Multi-level Converter for Offshore High-voltage DC Application under Various Grid Faults

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang;

    2016-01-01

    The modular multi-level converter has become an interesting candidate in high-voltage DC systems due to its higher voltage levels and modular construction. Low-voltage ride-through is an important grid requirement for modular multi-level converter–high-voltage DC since not only causes control...... challenges but may also result in overstressed components for the modular multi-level converter. However, the thermal loading of the modular multi-level converter under various grid faults has not yet been clarified. In this article, the power loss and thermal performance of the modular multi-level converter...... during grid voltage dips are studied. The impacts of two typical grid faults to the modular multi-level converter in terms of operating and loading conditions are analytically researched and simulated. It has been found that the operating and loading conditions of the modular multi-level converter under...

  8. Studying mechanosensitive ion channels with an automated patch clamp

    NARCIS (Netherlands)

    Barthmes, Maria; Jose, Mac Donald F; Birkner, Jan Peter; Brüggemann, Andrea; Wahl-Schott, Christian; Kocer, Armagan

    2014-01-01

    Patch clamp electrophysiology is the main technique to study mechanosensitive ion channels (MSCs), however, conventional patch clamping is laborious and success and output depends on the skills of the operator. Even though automated patch systems solve these problems for other ion channels, they cou

  9. Applications of alcohol clamping in early drug development

    NARCIS (Netherlands)

    Zoethout, Remco Wiebe Martijn

    2012-01-01

    This thesis describes the development of a novel alcohol clamp, a new method to obtain stable plasma levels of alcohol and its application in CNS-research. The method might have several advantages that were explored in subsequent studies described in this thesis. The stability of the alcohol clamp w

  10. OPTIMAL TIMING FOR CLAMPING THE UMBILICAL CORD AFTER BIRTH

    Science.gov (United States)

    Raju, Tonse N. K.; Singal, Nalini

    2013-01-01

    Synopsis This paper provides a brief overview of pros and cons of clamping the cord too early (within seconds) after birth. It also highlights evolving data that suggests that delaying cord clamping for 30–60 seconds after birth is beneficial to the baby and the mother, with no measurable negative effects. PMID:23164185

  11. 21 CFR 876.5160 - Urological clamp for males.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urological clamp for males. 876.5160 Section 876.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5160 Urological clamp for...

  12. 电力系统电压稳定分析方法综述%Analysis Methods for Power System Voltage Stability

    Institute of Scientific and Technical Information of China (English)

    王卓欣; 李禹鹏

    2014-01-01

    In order to further explore the mechanism of voltage stability of power system,compared and sum-marized of the existing analysis methods of voltage stability.Static voltage stability analysis is the study of the equilibrium problem of system dynamic equation,can only given the necessary condition of voltage stability. Because of its simple and fast algorithm,it is widely used.Dynamic voltage stability analysis is the study of the deep understanding of the mechanism of voltage stability and important basis and tools for voltage stability control.Introduces the mathematical model for voltage stability as a starting point,the unified mathematical model of the framework,and analyzes the static voltage stability analysis (including the eigenvalue analysis, model analysis,sensitivity analysis,the method of continuous tide and collapse point method)and the dynamic analysis method (the time domain simulation analysis,the small disturbance analysis and bifurcation analysis) of the theoretical basis,mathematical model,the physical significance,scope of application,which can help to provide the reference of reasonable selection of power system voltage stability analysis method.%为了进一步探索电力系统的电压稳定机制,对已有的电压稳定分析方法进行了比较和总结。电压稳定静态分析法研究的是系统动态方程的平衡点问题,只能给出电压稳定的必要条件,由于算法简单快速,得到广泛应用;电压稳定动态分析法研究的是深入理解电压稳定机理和进行电压稳定控制的重要基础和工具。介绍了以电压稳定数学模型为出发点,在统一的数学模型框架内,分析了电压稳定静态分析法(包括特征值分析法、模式分析法、灵敏度分析法、连续潮流法和崩溃点法)和动态分析法(时域仿真分析法、小扰动分析法和分岔分析法)的理论基础、数学模型、物理意义、适用范围等信息,以期为合理选

  13. Voltage stability dynamical analysis by comparing static and dynamical loads; Estudio dinamico de estabilidad de tension comparando modelos de carga estatica y carga dinamica

    Energy Technology Data Exchange (ETDEWEB)

    Aromataris, Luis [Universidad Nacional de Rio Cuarto (UNRC) (Argentina); Arnera, Patricia; Riubrugent, Jean [Universidad Nacional de La Plata, Buenos Aires (Argentina). Facultad de Ingenieria. Instituto de Investigaciones Tecnologicas para Redes y Equipos Electricos

    2001-07-01

    This work investigate the impact produced by the load model on the voltage stability analysis of an electric system. Qualitative and quantitative analyses are approached in connection with the effects of modeling the electric loads by both dynamical and static way. Also it is highlighted the importance of using dynamical models of load, mainly when it is composed by motors.

  14. Theoretical analysis and design of double implanted MOSFET on 6H silicon carbide wafer for low power dissipation and large breakdown voltage

    Directory of Open Access Journals (Sweden)

    Munish Vashishath

    2008-05-01

    Full Text Available This paper analyses the device structure of a 6H-SiC vertical double-implanted MOSFET (DIMOSFET in order to provide a high breakdown voltage of about 10 kV and a low power dissipation for a rise in device temperature of 600 oC. Analysis of an 800 W power dissipation for stable device operation corresponding to this temperature rise shows optimum doping levels of the drift region lying between 5*1013 cm-3 and 5*1015 cm-3 for a breakdown voltage of 10 kV.

  15. Correlation of open cell-attached and excised patch clamp techniques.

    Science.gov (United States)

    Filipovic, D; Hayslett, J P

    1995-11-01

    The excised patch clamp configuration provides a unique technique for some types of single channel analyses, but maintenance of stable, long-lasting preparations may be confounded by rundown and/or rapid loss of seal. Studies were performed on the amiloride-sensitive Na+ channel, located on the apical surface of A6 cells, to determine whether the nystatin-induced open cell-attached patch could serve as an alternative configuration. Compared to excised inside-out patches, stable preparations were achieved more readily with the open cell-attached patch (9% vs. 56% of attempts). In both preparations, the current voltage (I-V) relation was linear, current amplitudes were equal at opposite equivalent clamped voltages, and Erev was zero in symmetrical Na+ solutions, indicating similar Na+ activities on the cytosolic and external surfaces of the patch. Moreover, there was no evidence that nystatin altered channel activity in the patch because slope conductance (3-4pS) and Erev (75 mV), when the bath was perfused with a high K:low Na solution (ENa = 80 mV), were nearly equal in both patch configurations. Our results therefore indicate that the nystatin-induced open cell-attached patch can serve as an alternative approach to the excised inside-out patch when experiments require modulation of univalent ions in the cytosol.

  16. Space vector-based analysis of overmodulation in triangle-comparison based PWM for voltage source inverter

    Indian Academy of Sciences (India)

    Manoj Kumar Modi; S Venugopal; G Narayanan

    2013-06-01

    The equivalence of triangle-comparison-based pulse width modulation (TCPWM) and space vector based PWM (SVPWM) during linear modulation is well-known. This paper analyses triangle-comparison based PWM techniques (TCPWM) such as sine-triangle PWM (SPWM) and common-mode voltage injection PWM during overmodulation from a space vector point of view. The average voltage vector produced by TCPWM during overmodulation is studied in the stationary (a–b) reference frame. This is compared and contrasted with the average voltage vector corresponding to the well-known standard two-zone algorithm for space vector modulated inverters. It is shown that the two-zone overmodulation algorithm itself can be derived from the variation of average voltage vector with TCPWM. The average voltage vector is further studied in a synchronously revolving (d-q) reference frame. The RMS value of low-order voltage ripple can be estimated, and can be used to compare harmonic distortion due to different PWM methods during overmodulation. The measured values of the total harmonic distortion (THD) in the line currents are presented at various fundamental frequencies. The relative values of measured current THD pertaining to different PWM methods tally with those of analytically evaluated RMS voltage ripple.

  17. 农业装备中三电平二极管箝位式逆变器拓扑结构的改进%Improved neutral point clamped three-level VSI topology construction in agricultural device

    Institute of Scientific and Technical Information of China (English)

    刘国海; 钱鹏; 陈兆岭; 沈跃; 廖志凌

    2013-01-01

    transformation is not required, the control scheme is simple. Further, a theoretical analysis of the system stability was achieved. In order to verify the proposed control method, the system was simulated by using the “Power system Blockset”in the Matlab/Simulink environment. The parameters used for simulation are defined as follows:us=3000 V,udc=500 V, dc link capacitor, C=1000 uF, L=0.4 mH, the switching frequency of the NPC three-level inverter was 3kHz, and the switching frequency of the active compensation voltage device was 10 kHz. After the compensation, a voltage fluctuation value of the three-phase bridge arm neutral-point in the traditional NPC three-level inverter was limited under 3%. In addition, simulation results showed that the proposed topology has good dynamic performance. In conclusion, a NPC three-level inverter with a neutral-point voltage self-balancing function was proposed due to the problem of neutral-point voltage excessive fluctuation of a traditional neutral point clamped (NPC) three-level inverter. This structure consisted of an active compensation voltage device to eliminate the neutral-point voltage excessive fluctuation. Simulation results have shown that no matter how the load varies, the presented circuit structure can eliminate the three-phase bridge arm neutral-point voltage fluctuation effectively with quick response and good dynamic performance.%传统的二极管箝位式(NPC)三电平逆变器结构中,中点电压波动过大将导致输出电压的谐波总畸变率(total harmonic distortion,THD)增大及开关器件损坏,影响了该结构在农业机电中的应用。该文提出了一种带中点电压自平衡的NPC三电平逆变器拓扑结构,通过在传统NPC三电平逆变器结构中加入一套由单相全桥逆变电路组成的电压主动补偿装置,对三相桥臂中点电压的波动进行主动补偿。实时检测三相桥臂中点电压,与给定值比较后,控制补偿装置实时产生补偿

  18. Analysis and Comparison of Voltage Dependent Charging Strategies for Single-Phase Electric Vehicles in an Unbalanced Danish Distribution Grid

    DEFF Research Database (Denmark)

    Álvarez, Jorge Nájera; Knezovic, Katarina; Marinelli, Mattia

    2016-01-01

    This paper studies four voltage dependent solutions for modulating the charging of multiple Electric Vehicles (EVs) in a real Danish network. Uncontrolled EV charging, especially in grid with high EV penetration, can result in overloaded lines and transformers, low-voltages and other performance......-in on phases with lower voltages are constrained during the charging period. In order to solve instability issues which may occur due to lack of communication between the controllers, several improvements are applied to the aforementioned droop control. Simulation results demonstrate the performance...

  19. Meta-Analysis of Public Microarray Datasets Reveals Voltage-Gated Calcium Gene Signatures in Clinical Cancer Patients.

    Directory of Open Access Journals (Sweden)

    Chih-Yang Wang

    Full Text Available Voltage-gated calcium channels (VGCCs are well documented to play roles in cell proliferation, migration, and apoptosis; however, whether VGCCs regulate the onset and progression of cancer is still under investigation. The VGCC family consists of five members, which are L-type, N-type, T-type, R-type and P/Q type. To date, no holistic approach has been used to screen VGCC family genes in different types of cancer. We analyzed the transcript expression of VGCCs in clinical cancer tissue samples by accessing ONCOMINE (www.oncomine.org, a web-based microarray database, to perform a systematic analysis. Every member of the VGCCs was examined across 21 different types of cancer by comparing mRNA expression in cancer to that in normal tissue. A previous study showed that altered expression of mRNA in cancer tissue may play an oncogenic role and promote tumor development; therefore, in the present findings, we focus only on the overexpression of VGCCs in different types of cancer. This bioinformatics analysis revealed that different subtypes of VGCCs (CACNA1C, CACNA1D, CACNA1B, CACNA1G, and CACNA1I are implicated in the development and progression of diverse types of cancer and show dramatic up-regulation in breast cancer. CACNA1F only showed high expression in testis cancer, whereas CACNA1A, CACNA1C, and CACNA1D were highly expressed in most types of cancer. The current analysis revealed that specific VGCCs likely play essential roles in specific types of cancer. Collectively, we identified several VGCC targets and classified them according to different cancer subtypes for prospective studies on the underlying carcinogenic mechanisms. The present findings suggest that VGCCs are possible targets for prospective investigation in cancer treatment.

  20. Model parameter estimation approach based on incremental analysis for lithium-ion batteries without using open circuit voltage

    Science.gov (United States)

    Wu, Hongjie; Yuan, Shifei; Zhang, Xi; Yin, Chengliang; Ma, Xuerui

    2015-08-01

    To improve the suitability of lithium-ion battery model under varying scenarios, such as fluctuating temperature and SoC variation, dynamic model with parameters updated realtime should be developed. In this paper, an incremental analysis-based auto regressive exogenous (I-ARX) modeling method is proposed to eliminate the modeling error caused by the OCV effect and improve the accuracy of parameter estimation. Then, its numerical stability, modeling error, and parametric sensitivity are analyzed at different sampling rates (0.02, 0.1, 0.5 and 1 s). To identify the model parameters recursively, a bias-correction recursive least squares (CRLS) algorithm is applied. Finally, the pseudo random binary sequence (PRBS) and urban dynamic driving sequences (UDDSs) profiles are performed to verify the realtime performance and robustness of the newly proposed model and algorithm. Different sampling rates (1 Hz and 10 Hz) and multiple temperature points (5, 25, and 45 °C) are covered in our experiments. The experimental and simulation results indicate that the proposed I-ARX model can present high accuracy and suitability for parameter identification without using open circuit voltage.

  1. A Manufacturing Cost and Supply Chain Analysis of SiC Power Electronics Applicable to Medium-Voltage Motor Drives

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, Kelsey [National Renewable Energy Lab. (NREL), Golden, CO (United States); Remo, Timothy [National Renewable Energy Lab. (NREL), Golden, CO (United States); Reese, Samantha [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-03-24

    Wide bandgap (WBG) semiconductor devices are increasingly being considered for use in certain power electronics applications, where they can improve efficiency, performance, footprint, and, potentially, total system cost compared to systems using traditional silicon (Si) devices. Silicon carbide (SiC) devices in particular -- which are currently more mature than other WBG devices -- are poised for growth in the coming years. Today, the manufacturing of SiC wafers is concentrated in the United States, and chip production is split roughly equally between the United States, Japan, and Europe. Established contract manufacturers located throughout Asia typically carry out manufacturing of WBG power modules. We seek to understand how global manufacturing of SiC components may evolve over time by illustrating the regional cost drivers along the supply chain and providing an overview of other factors that influence where manufacturing is sited. We conduct this analysis for a particular case study where SiC devices are used in a medium-voltage motor drive.

  2. NBTI-Aware Transient Fault Rate Analysis Method for Logic Circuit Based on Probability Voltage Transfer Characteristics

    Directory of Open Access Journals (Sweden)

    Zhiming Yang

    2016-01-01

    Full Text Available The reliability of Very Large Scale Integration (VLSI circuits has become increasingly susceptible to transient faults induced by environmental noise with the scaling of technology. Some commonly used fault tolerance strategies require statistical methods to accurately estimate the fault rate in different parts of the logic circuit, and Monte Carlo (MC simulation is often applied to complete this task. However, the MC method suffers from impractical computation costs due to the size of the circuits. Furthermore, circuit aging effects, such as negative bias temperature instability (NBTI, will change the characteristics of the circuit during its lifetime, leading to a change in the circuit’s noise margin. This change will increase the complexity of transient fault rate estimation tasks. In this paper, an NBTI-aware statistical analysis method based on probability voltage transfer characteristics is proposed for combinational logic circuit. This method can acquire accurate fault rates using a discrete probability density function approximation process, thus resolving the computation cost problem of the MC method. The proposed method can also consider aging effects and analyze statistical changes in the fault rates. Experimental results demonstrate that, compared to the MC simulation, our method can achieve computation times that are two orders of magnitude shorter while maintaining an error rate less than 9%.

  3. 电缆绝缘电阻测试仪中高压电源的设计*%Design of High-Voltage Power Supply of Cable Insulation Resistance Tester

    Institute of Scientific and Technical Information of China (English)

    李琳琳; 王二宝; 孙继银; 恒波; 肖明芳

    2013-01-01

      To meet the power requirements of inputting low voltage and outputting high-voltage during cable insulation resistance test, the paper proposes a new type of active clamp voltage multiplying converters by analyzing and improving the technical of analysis active clamp pulse width modulation and voltage double rectifier. It uses main circuit in active clamp technique to achieve magnetic core flux automatic reset and increases core utilization. The clamp capacitor with other components produces resonant achieving opened switch to zero pressure, which reduces the switching loss and voltage stress. Doubling voltage technique is used to reduce transformer step-up requirements and converter bulk. Taking advantage of negative feedback in control loop,input output voltage into PWM chip and control pulse duty cycle can increase power stability and load characteristics. The software simulation result shows that the converter is able to provide a stable high insulation resistance test voltage.%  为满足电缆绝缘电阻测试“低电压输入,高电压输出”的需求,对有源钳位、脉宽调制和倍压整流等技术分析改进,提出一种新型的有源钳位倍压变换器。主回路中利用有源钳位技术实现磁芯磁通自动复位,提高了磁芯利用率,钳位电容与元器件产生谐振实现开关零压开通,减小开关损耗和电压应力;利用倍压技术降低变压器升压要求,减小了变换器体积;在控制回路中利用负反馈将输出电压输入脉宽调制芯片,控制脉冲占空比,提高了电源稳定性和负载特性。用软件仿真结果表明,该变换器能够为绝缘电阻测试提供稳定的高电压。

  4. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    OpenAIRE

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia; Han, Xue

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis. The load profiles are characterized by using single phase measurement data on voltages, currents and active powers with a 10 minutes resolution. Different scenarios are considered: no tap action, th...

  5. Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

    Science.gov (United States)

    Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.

    1982-01-01

    Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.

  6. Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

    Science.gov (United States)

    Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.

    Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.

  7. Analysis, Design, and Experimental Verification of A Synchronous Reference Frame Voltage Control for Single-Phase Inverters

    DEFF Research Database (Denmark)

    Monfared, Mohammad; Golestan, Saeed; Guerrero, Josep M.

    2014-01-01

    damping and improve both transient and steady-state performances, a voltage decoupling feedforward to improve the system robustness, and a multi-resonant harmonic compensator to prevent low-order load current harmonics to distort the inverter output voltage. Since, the voltage loop works......Control of three-phase power converters in the synchronous reference frame is now a mature and well developed research topic. However, for single-phase converters, it is not as well-established as three-phase applications. This paper deals with the design of a synchronous reference frame multi......-loop control strategy for single phase inverter-based islanded distributed generation (DG) systems. The proposed controller uses a synchronous reference frame PI (SRFPI) controller to regulate the instantaneous output voltage, a capacitor current shaping loop in the stationary reference frame to provide active...

  8. Analysis of cutting-edge techniques in the high voltage and high power adjustable speed drive systems

    Institute of Scientific and Technical Information of China (English)

    ZHAO ZhengMing; BAI Hua; YUAN LiQiang

    2009-01-01

    The high voltage and high power adjustable speed drive (ASD) system is one of the most attractive fields in power electronics, and it is also a very crucial technique for energy saving and emission re-duction. This paper discussed and analyzed the main cutting-edge knowledge and issues in the proc-ess of exploiting the high voltage and high power ASD system.

  9. Interleaved soft-switched active-clamped L-L type current-fed half-bridge DC-DC converter for fuel cell applications

    Energy Technology Data Exchange (ETDEWEB)

    Rathore, Akshay K. [Electrical Machines and Drives Research Lab, University of Wuppertal, Rainer Gruenter Str. 21, University Campus Freudenberg, 42119 Wuppertal, NRW (Germany)

    2009-12-15

    In this paper, an interleaved soft-switched active-clamped L-L type current-fed half-bridge isolated dc-dc converter has been proposed. The L-L type active-clamped current-fed converter is able to maintain zero-voltage switching (ZVS) of all switches for the complete operating range of wide fuel cell stack voltage variation at full load down to light load conditions. Active-clamped circuit absorbs the turn-off voltage spike across the switches. Half-bridge topology maintains higher efficiency due to lower conduction losses. Soft-switching permits higher switching frequency operation, reducing the size, weight and cost of the magnetic components. Interleaving of the two isolated converters is done using parallel input series output approach and phase-shifted modulation is adopted. It reduces the input current ripple at the fuel cell input, which is required in a fuel cell system and also reduces the output voltage ripples. In addition, the size of the magnetic/passive components, current rating of the switches and voltage ratings of the rectifier diodes are reduced. (author)

  10. Analysis on voltage oscillation of a mid-frequency series resonant inverter for DRMP coils on J-TEXT

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Long-jian, E-mail: liulongjian001@yeah.net [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Yu, Ke-xun; Zhang, Ming; Nan, Jie-yin; Jiang, Guo-zhong; Rao, Bo; Li, Xuan [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2016-01-15

    Highlights: • The reason of high-voltage oscillation of a series resonant inverter for DRMP coils is analyzed. • The condition or method for reduction of high-voltage oscillation is discussed. • The considerations of dead time and switch frequency for reduction of high-voltage oscillation are discussed. - Abstract: This paper deals with the voltage oscillation of an AC power supply for generating dynamic magnetic perturbation (DRMP) on J-TEXT. The power supply is a series resonant inverter with a matching transformer. It was noted that the high-voltage oscillation at transformer primary side is caused by an interaction between the line inductance and the stray capacitance of the matching transformer at switching transitions. In order to reduce the high-voltage oscillation and consider the requirement for soft-switching technique simultaneously, the switching frequency should be chosen properly by fine-tuning. The dead time should be chosen according to the relative size of minimum required dead time for protection and the optimal dead time.

  11. Committee Opinion No. 684: Delayed Umbilical Cord Clamping After Birth.

    Science.gov (United States)

    2017-01-01

    Delayed umbilical cord clamping appears to be beneficial for term and preterm infants. In term infants, delayed umbilical cord clamping increases hemoglobin levels at birth and improves iron stores in the first several months of life, which may have a favorable effect on developmental outcomes. There is a small increase in jaundice that requires phototherapy in this group of infants. Consequently, health care providers adopting delayed umbilical cord clamping in term infants should ensure that mechanisms are in place to monitor for and treat neonatal jaundice. In preterm infants, delayed umbilical cord clamping is associated with significant neonatal benefits, including improved transitional circulation, better establishment of red blood cell volume, decreased need for blood transfusion, and lower incidence of necrotizing enterocolitis and intraventricular hemorrhage. Delayed umbilical cord clamping was not associated with an increased risk of postpartum hemorrhage or increased blood loss at delivery, nor was it associated with a difference in postpartum hemoglobin levels or the need for blood transfusion. Given the benefits to most newborns and concordant with other professional organizations, the American College of Obstetricians and Gynecologists now recommends a delay in umbilical cord clamping in vigorous term and preterm infants for at least 30-60 seconds after birth. The ability to provide delayed umbilical cord clamping may vary among institutions and settings; decisions in those circumstances are best made by the team caring for the mother-infant dyad.

  12. Neutral Point Clamped Npc Type Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    Purohit Sadanand Chandrashekhar

    2015-08-01

    Full Text Available Concept of the multilevel inverter is same as the other inverter which is to converts Direct current DC to Alternating current AC .The inverted current can be at any vital voltage and frequency with the use of pertinent transformers switching and control circuits. From the source like batteries solar panel wind turbine or fuel cell the inverter will convert the DC electricity to AC electricity. In this modern technology Power electronics is very important where it used in a great variety of product. With the high potential in high power for industry multilevel inverter will become most popular for so many applications.

  13. Avoiding aortic clamping during CABG reduces postoperative stroke

    Science.gov (United States)

    Moss, Emmanuel; Puskas, John D; Thourani, Vinod H; Kilgo, Patrick; Chen, Edward P; Leshnower, Bradley G; Lattouf, Omar M; Guyton, Robert A.; Glas, Kathryn E; Halkos, Michael E.

    2014-01-01

    Objective The purpose of this study was to determine whether the incidence of postoperative stroke (PS) could be reduced by eliminating aortic clamping during CABG. Methods From 2002–2013, 12,079 patients underwent primary, isolated CABG at a single US academic institution. Aortic manipulation was completely avoided by using in-situ internal mammary arteries for inflow in 1,552 (12.9%) patients (no-touch), a clampless facilitating device (CFD) was used for proximal anastomoses in 1,548 (12.8%) patients, and aortic clamping was used in 8,979 (74.3%) patients. These strategies were assessed in a logistic regression model controlling for relevant variables. Results The overall incidence of PS was 1.4% (n=165), with an unadjusted incidence of 0.6% (n=10) in the no-touch group, 1.2% (n=18) in the CFD group, and 1.5% (n=137) in the clamp group (p<0.01 for no-touch vs clamp). The ratio of observed to expected stroke rate increased as the degree of aortic manipulation increased, from 0.48 in the no-touch group, to 0.61 in the CFD group, and 0.95 in the clamp group. Aortic clamping was independently associated with an increase in PS compared to a no-touch technique (AOR 2.50, p<0.01). When separated by CPB utilization, both the off-pump partial clamp and on-pump cross-clamp techniques increased the risk of PS compared to no-touch (AOR 2.52, p<0.01 and AOR 4.25, p<0.001, respectively). Conclusion A no-aortic touch technique has the lowest risk for postoperative stroke for patients undergoing CABG. Clamping the aorta during CABG increases the risk of PS, regardless of the severity of aortic disease. PMID:25293356

  14. Is "Delayed Umbilical Cord Clamping" Beneficial for Premature Newborns?

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2017-05-01

    Full Text Available Background: The appropriate moment for clamping the umbilical cord is controversial. Immediate cord clamping (ICC is an item of active management of the third stage of labor (AMTSL. Unclamped umbilical cord may cause inconvenience in preterm neonates because they commonly need some levels of emergent services. Some studies revealed delayed cord clamping (DCC of preterm neonates results in better health conditions like lower rates of respiratory distress syndrome (RDS, less morbidities in labor room and lower risk of postpartum hemorrhage. The aim of the present study was to determine the effect of delayed umbilical cord clamping on premature neonatal outcomes. Materials and Methods: In this single‑center randomized control trial study, sixty premature neonates (gestational age ≤ 34 weeks were randomly assigned to ICC (cord clamped at 5–10 seconds or DCC (30–45 seconds groups and followed up in neonatal intensive care unit (NICU. Primary outcomes were 1st and 5th minute Apgar score, average of level of hematocrit after birth, intra ventricle hemorrhage and need some levels of resuscitation. Results: Differences in demographic characteristics were not statistically significant. After birth, neonates who had delayed clamping had significantly higher mean hematocrit after at 4-hour of birth (49.58+5.15gr/dl vs. 46.58+5.40gr/dlin DCC vs. ICC groups, respectively (P=0.031. Delayed cord clamping reduced the duration of need to nasal continues positive airway pressure (NCPAP (86.7% and 60.0% in ICC and DCC groups, respectively, P= 0.039. Attractively, the results showed lower incidence of clinical sepsis in delayed cord clamping neonates (53.3% vs. 23.3% in ICC and DCC groups, respectively, P=0.033. Conclusion: Prematurity complications might decrease by delay umbilical cord clamping which improve the hematocrit, duration of need to NCPAP and incidence of clinical sepsis. Furthermore, DCC may have no negative impact on neonatal resuscitation.

  15. Effect of timing of umbilical cord clamping on iron status in Mexican infants: a randomised controlled trial.

    Science.gov (United States)

    Chaparro, Camila M; Neufeld, Lynnette M; Tena Alavez, Gilberto; Eguia-Líz Cedillo, Raúl; Dewey, Kathryn G

    2006-06-17

    Delayed clamping of the umbilical cord increases the infant's iron endowment at birth and haemoglobin concentration at 2 months of age. We aimed to assess whether a 2-minute delay in the clamping of the umbilical cord of normal-weight, full-term infants improved iron and haematological status up to 6 months of age. 476 mother-infant pairs were recruited at a large obstetrics hospital in Mexico City, Mexico, randomly assigned to delayed clamping (2 min after delivery of the infant's shoulders) or early clamping (around 10 s after delivery), and followed up until 6 months postpartum. Primary outcomes were infant haematological status and iron status at 6 months of age, and analysis was by intention-to-treat. This study is registered with ClinicalTrials.gov, number NCT00298051. 358 (75%) mother-infant pairs completed the trial. At 6 months of age, infants who had delayed clamping had significantly higher mean corpuscular volume (81.0 fL vs 79.5 fL 95% CI -2.5 to -0.6, p=0.001), ferritin (50.7 mug/L vs 34.4 mug/L 95% CI -30.7 to -1.9, p=0.0002), and total body iron. The effect of delayed clamping was significantly greater for infants born to mothers with low ferritin at delivery, breastfed infants not receiving iron-fortified milk or formula, and infants born with birthweight between 2500 g and 3000 g. A cord clamping delay of 2 minutes increased 6-month iron stores by about 27-47 mg. Delay in cord clamping of 2 minutes could help prevent iron deficiency from developing before 6 months of age, when iron-fortified complementary foods could be introduced.

  16. Finite Element Analysis of voltage effect in the MechanicalBehavior of Diaphragm of Electrostatic Micro-pumps

    Directory of Open Access Journals (Sweden)

    Hamid masoudi sadaghiani

    2016-06-01

    Full Text Available Micro-pumps are one of the most important devices in the field of micro-fluids which have many applications in biomedical engineering. Electrostatic stimulation is one of the mechanisms of stimulation in the micro-pumps that due to low power consumption and comfortable control have very much application in this field. Various phenomena occurs in micro-pumps, electrostatic induction that influence the efficiency and efficacy of this devices. One of these phenomena have been Pull-in instability which is a static phenomenon and occurs when the applied voltage exceeds a critical level. In this case, the diaphragm of micro pump get absorbed into opposite fixed electrode and instability occurs in the system. Therefore, understanding the relationship between pull-in voltage by external factors (for example, the physical characteristics of the device help designers to customize these factors in order to take their required output from device. To estimate the pull-in voltage, for an electrostatic diaphragm computer simulation of finite elements were used. According to the results obtained from the Software, the voltage in steps of 0.025, V = 313/925 which is best answer to unstable Static voltage.The amount of voltage for dynamic mode is approximately 0.91 of static value that is v = 284.41v obtained by software. Comparing the results it can be observed that in the case of unstable Static voltage there is little difference between results. So with this software Mechanical Behavior of Micro Analytical review pages that is difficult and time-consuming can be studied.And the results are used in the design of MEMS that these elements are used in the micro-plates.

  17. Grid Filter Design for a Multi-Megawatt Medium-Voltage Voltage Source Inverter

    DEFF Research Database (Denmark)

    Rockhill, A.A.; Liserre, Marco; Teodorescu, Remus

    2011-01-01

    This paper describes the design procedure and performance of an LCL grid filter for a medium-voltage neutral point clamped (NPC) converter to be adopted for a multimegawatt wind turbine. The unique filter design challenges in this application are driven by a combination of the medium voltage......-megawatt filter connecting a medium-voltage converter switching at low frequency to the electric grid. This paper demonstrates a frequency domain model based approach to determine the optimum filter parameters that provide the necessary performance under all operating conditions given the necessary design...... converter, a limited allowable switching frequency, component physical size and weight concerns, and the stringent limits for allowable injected current harmonics. Traditional design procedures of grid filters for lower power and higher switching frequency converters are not valid for a multi...

  18. Grid Filter Design for a Multi-Megawatt Medium-Voltage Voltage Source Inverter

    DEFF Research Database (Denmark)

    Rockhill, A.A.; Liserre, Marco; Teodorescu, Remus

    2011-01-01

    converter, a limited allowable switching frequency, component physical size and weight concerns, and the stringent limits for allowable injected current harmonics. Traditional design procedures of grid filters for lower power and higher switching frequency converters are not valid for a multi......This paper describes the design procedure and performance of an LCL grid filter for a medium-voltage neutral point clamped (NPC) converter to be adopted for a multimegawatt wind turbine. The unique filter design challenges in this application are driven by a combination of the medium voltage......-megawatt filter connecting a medium-voltage converter switching at low frequency to the electric grid. This paper demonstrates a frequency domain model based approach to determine the optimum filter parameters that provide the necessary performance under all operating conditions given the necessary design...

  19. High Power Neutral Point Clamped (NPC Multilevel UPFC with DC Link Switch for Effective Control of Real & Reactive Power

    Directory of Open Access Journals (Sweden)

    R Sanjay Kumar

    2016-01-01

    Full Text Available High-voltage and power capability of multilevel converters better used for unified power-flow controller (UPFC applications. The three-level neutral-point-clamped (NPC converter allows back-to-back connection as the UPFC shunt and series converters than other multilevel topologies. In place of the pulse width-modulated (PWM multilevel control schemes, constant dc-link voltage and balanced voltages in the NPC multilevel dc capacitors is necessary for UPFCs. The proposed work provides three main contributions to increase the performance of the system of multilevel UPFCs as this can be operated in STATCOM, SSSC and exactly in the UPFC mode with the double balancing of dc capacitor voltages under line faults, overall enhancing the UPFC ride-through capability. NPC series and shunt converters keep the dc-link voltage steady. Transients are the causes of fault in power system, Power System Stabilizer (PSS and Automatic Voltage Regulator (AVR are used to stabilize the response. The voltage regulator and current controller plays important roll to generate control pulses for VSC. A MATLAB simulation has been carried out to demonstrate the performance of the proposed model for UPFC in achieving transient stability with real and reactive power control.

  20. High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1995-01-01

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  1. VOLTAGE-DEPENDENT SODIUM AND POTASSIUM, BUT NO CALCIUM CONDUCTANCES IN DDT1 MF-2 SMOOTH-MUSCLE CELLS

    NARCIS (Netherlands)

    MOLLEMAN, A; NELEMANS, A; VANDENAKKER, J; DUIN, M; DENHERTOG, A

    1991-01-01

    Voltage-dependent inward and outward membrane currents were investigated in the DDT1 MF-2 smooth muscle cell line using the whole-cell patch-clamp technique. Application of a pulse protocol with subsequent depolarizing voltage steps elicited an inactivating inward current and a non-inactivating outw

  2. Medium voltage three-level converters for the grid connection of a multi-MW wind turbine

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig;

    2009-01-01

    Three-level (3L) neutral point clamped (NPC), flying capacitor (FC), and H-bridge (HB) voltage source converters (VSCs) as a grid-side full-scale medium voltage (MV) converter are modeled, controlled, and simulated for the grid connection of a hypothetical 6MW wind turbine. Via the converter topo...

  3. Replication factor C is a more effective proliferating cell nuclear antigen (PCNA) opener than the checkpoint clamp loader, Rad24-RFC.

    Science.gov (United States)

    Thompson, Jennifer A; Marzahn, Melissa R; O'Donnell, Mike; Bloom, Linda B

    2012-01-13

    Clamp loaders from all domains of life load clamps onto DNA. The clamp tethers DNA polymerases to DNA to increase the processivity of synthesis as well as the efficiency of replication. Here, we investigated proliferating cell nuclear antigen (PCNA) binding and opening by the Saccharomyces cerevisiae clamp loader, replication factor C (RFC), and the DNA damage checkpoint clamp loader, Rad24-RFC, using two separate fluorescence intensity-based assays. Analysis of PCNA opening by RFC revealed a two-step reaction in which RFC binds PCNA before opening PCNA rather than capturing clamps that have transiently and spontaneously opened in solution. The affinity of RFC for PCNA is about an order of magnitude lower in the absence of ATP than in its presence. The affinity of Rad24-RFC for PCNA in the presence of ATP is about an order magnitude weaker than that of RFC for PCNA, similar to the RFC-PCNA interaction in the absence of ATP. Importantly, fewer open clamp loader-clamp complexes are formed when PCNA is bound by Rad24-RFC than when bound by RFC.

  4. Onset of asphyxial state in nonrespiring interval between cord clamping and ventilation increases hemodynamic lability of birth transition in preterm lambs.

    Science.gov (United States)

    Smolich, Joseph J; Kenna, Kelly R; Cheung, Michael M

    2015-03-15

    Experimentally, a typical ∼2-min cord clamp-to-ventilation interval in preterm lambs is accompanied by increased hemodynamic lability of the birth transition. However, whether this lability is related to development of asphyxia after cord clamping, or can be avoided with a shorter clamp-to-ventilation interval, is unknown. To address these questions, anesthetized preterm fetal lambs (gestation 127 ± 2 days) were instrumented with ductus arteriosus and left pulmonary artery flow probes to obtain right ventricular (RV) output, brachiocephalic trunk and aortic isthmus flow probes to measure left ventricular (LV) output, and aortic trunk catheters for pressure measurement and blood gas analysis. With hemodynamics recorded continuously, fetuses were delivered onto the ewe's abdomen and the cord clamped for 1.5 min before ventilation (n = 8), with aortic sampling at 15, 30, 45, and 60 s, or for 0.5 min, with sampling at 15 s (n = 4). With 1.5-min cord clamping, an asphyxial state (Po2 cord clamping, with no postventilation change in heart rate or RV output, and a lesser rise in LV output (22%, P cord clamp-to-ventilation interval increased hemodynamic lability of the birth transition, which was reduced with a shorter (∼0.5 min) cord clamp-to-ventilation interval. Copyright © 2015 the American Physiological Society.

  5. A clamp-like biohybrid catalyst for DNA oxidation

    Science.gov (United States)

    van Dongen, Stijn F. M.; Clerx, Joost; Nørgaard, Kasper; Bloemberg, Tom G.; Cornelissen, Jeroen J. L. M.; Trakselis, Michael A.; Nelson, Scott W.; Benkovic, Stephen J.; Rowan, Alan E.; Nolte, Roeland J. M.

    2013-11-01

    In processive catalysis, a catalyst binds to a substrate and remains bound as it performs several consecutive reactions, as exemplified by DNA polymerases. Processivity is essential in nature and is often mediated by a clamp-like structure that physically tethers the catalyst to its (polymeric) template. In the case of the bacteriophage T4 replisome, a dedicated clamp protein acts as a processivity mediator by encircling DNA and subsequently recruiting its polymerase. Here we use this DNA-binding protein to construct a biohybrid catalyst. Conjugation of the clamp protein to a chemical catalyst with sequence-specific oxidation behaviour formed a catalytic clamp that can be loaded onto a DNA plasmid. The catalytic activity of the biohybrid catalyst was visualized using a procedure based on an atomic force microscopy method that detects and spatially locates oxidized sites in DNA. Varying the experimental conditions enabled switching between processive and distributive catalysis and influencing the sliding direction of this rotaxane-like catalyst.

  6. The cardiovascular effects of aortic clamping and unclamping

    African Journals Online (AJOL)

    An increase in the slope of the Ea line represents an increase in ... increase. (for example as the subject exercises), stroke work ... aortic clamping is that afterload and blood pressure increase ..... nitroglycerine does not increase heart rate nor.

  7. Delay in Clamping Umbilical Cord Benefits Babies, Doctors Say

    Science.gov (United States)

    ... doctors' group said. Although delayed clamping increases the newborn's risk of jaundice that will require treatment, ACOG said there's no evidence that waiting increases the mother's risk of hemorrhage. The guidelines are to be published in the ...

  8. [Time of cord clamping and neonatal complications, a prospective study].

    Science.gov (United States)

    Rincón, D; Foguet, A; Rojas, M; Segarra, E; Sacristán, E; Teixidor, R; Ortega, A

    2014-09-01

    To assess the effects of early or late clamping of the umbilical cord in term newborns, assessing the levels of hemoglobin, hematocrit, and ferritin, and their correlation with some of the complications. A prospective study of healthy newborns at term or born by dystotic or eutocic delivery in our hospital between May 2009 until May 2010. Patients were assigned according to the time of clamping, group 1 (clamping (g1: 111 mg/dl, g2: 125 mg/dl, g3: 173 mg/dl; pcord clamping is associated with an increase in hematocrit, hemoglobin and ferritin at 48 hours of life, as well as an increased risk of polycythemia present with symptoms. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  9. Interpretation of current-voltage relationships for "active" ion transport systems: I. Steady-state reaction-kinetic analysis of class-I mechanisms.

    Science.gov (United States)

    Hansen, U P; Gradmann, D; Sanders, D; Slayman, C L

    1981-01-01

    This paper develops a simple reaction-kinetic model to describe electrogenic pumping and co- (or counter-) transport of ions. It uses the standard steady-state approach for cyclic enzyme- or carrier-mediated transport, but does not assume rate-limitation by any particular reaction step. Voltage-dependence is introduced, after the suggestion of Läuger and Stark (Biochim. Biophys. Acta 211:458-466, 1970), via a symmetric Eyring barrier, in which the charge-transit reaction constants are written as k12 = ko12 exp(zF delta psi/2RT) and k21 = ko21 exp(-zF delta psi/2RT). For interpretation of current-voltage relationships, all voltage-independent reaction steps are lumped together, so the model in its simplest form can be described as a pseudo-2-state model. It is characterized by the two voltage-dependent reaction constants, two lumped voltage-independent reaction constants (k12, k21), and two reserve factors (ri, ro) which formally take account of carrier states that are indistinguishable in the current-voltage (I-V) analysis. The model generates a wide range of I-V relationships, depending on the relative magnitudes of the four reaction constants, sufficient to describe essentially all I-V datas now available on "active" ion-transport systems. Algebraic and numerical analysis of the reserve factors, by means of expanded pseudo-3-, 4-, and 5-state models, shows them to be bounded and not large for most combinations of reaction constants in the lumped pathway. The most important exception to this rule occurs when carrier decharging immediately follows charge transit of the membrane and is very fast relative to other constituent voltage-independent reactions. Such a circumstance generates kinetic equivalence of chemical and electrical gradients, thus providing a consistent definition of ion-motive forces (e.g., proton-motive force, PMF). With appropriate restrictions, it also yields both linear and log-linear relationships between net transport velocity and either

  10. Open-circuit voltage analysis of p-i-n type amorphous silicon solar cells deposited at low temperature

    Institute of Scientific and Technical Information of China (English)

    Ni Jian; Zhang Jian-Jun; Cao Yu; Wang Xian-Bao; Li Chao; Chen Xin-Liang; Geng Xin-Hua; Zhao Ying

    2011-01-01

    This paper identifies the contributions of p-a-SiC:H layers and i-a-Si:H layers to the open circuit voltage of p-i-n type a-Si:H solar cells deposited at a low temperature of 125 ℃.We find that poor quality p-a-SiC:H films under regular conditions lead to a restriction of open circuit voltage although the band gap of the i-layer varies widely.A significant improvement in open circuit voltage has been obtained by using high quality p-a-SiC:H films optimized at the "low-power regime" under low silane flow rates and high hydrogen dilution conditions.

  11. 考虑电压稳定的无功优化问题分析%Wattless optimization problems considering voltage stability analysis

    Institute of Scientific and Technical Information of China (English)

    李金炜

    2014-01-01

    The study of voltage stability and optimal reactive power control has important significance.This paper introduces a detailed analysis of voltage stability and optimal reactive power control to specific combination modes.Meanwhile,the corresponding measures for prevention and control are put forward according to the voltage stability of system operating point,which can guide the voltage stability problems.%目前,诸多学者和工作者都在研究电压稳定性的无功优化控制,该研究成为热点问题。本文详细分析了电压稳定和无功优化控制具体结合方式。同时,针对系统运行点电压稳定提出了相应的预防控制措施,从而能够指导电压稳定问题。

  12. Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis

    Directory of Open Access Journals (Sweden)

    Sai Ho Yeung

    2015-09-01

    Full Text Available Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC stimulation, magnetic stimulation (MS and transcutaneous electrical nerve stimulation (TENS are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissue voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.

  13. Analysis of Schottky barrier heights of metal/SiC contacts and its possible application to high-voltage rectifying devices

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, A. [Tokyo Inst. of Technol. (Japan). Dept. of Phys. Electron.; Matsunami, H. [Dept. of Electronic Science and Engineering, Kyoto Univ. (Japan)

    1997-07-16

    Schottky contacts of metal/3C-, 6H-, and 4H-SiC systems are investigated in this review. Most Schottky contacts having large barrier heights show good characteristics with low ideality factors. The barrier height depends on the metal work function without strong Fermi-level pinning for all polytypes, and linear relationships with slopes of about 0.2 to 0.7 are observed between the barrier height and the metal work function. Based on the analysis of metal/SiC systems, the fabrication of high-voltage rectifiers has been reported, and high voltages from 400 to 1100 V have been achieved using Pt/, Ti/, and Au/6H-SiC structures. In addition, high-temperature operation at 400 C is performed for an Au/6H-SiC structure while supporting a high reverse bias (460 V). Using Ti/4H-SiC structures, high-voltage ({approx}1000 V) and low-power loss characteristics are realized, which is superior to Ti/6H-SiC Schottky rectifiers. To improve the reverse bias characteristics, an edge termination technique is employed for Ti/4H-SiC Schottky rectifiers, and the devices show excellent characteristics with a higher blocking voltage up to 1750 V compared with unterminated devices. (orig.) 78 refs.

  14. Choosing the wire clamp microdrive for termosonic microwelding equipments

    Directory of Open Access Journals (Sweden)

    Lanin V. L.

    2010-06-01

    Full Text Available The article describes research of three types of wire clamp microdrive for termosonic microwelding equipment, covering an expanded range microconductors from 12,5 up to 75 mm. The most preferable, in the light of their high-speed and easy-programming qualities, proved to be the mechanisms of conductor clamp with piezoelement drives and the loading system based on "voice-coil" type electromagnet.

  15. Prehospital Emergency Inguinal Clamp Controls Hemorrhage in Cadaver Model

    Science.gov (United States)

    2013-07-01

    the CRoC preassembled for quick use. The clamp compresses the casualty’s tissues and is unat- tached to things like a litter. When screwed down, it is...for use on the battlefield to control difficult bleeds in the inguinal area. Study Design The study design was a sequence of experiments of clamp...temperature 4 hours before testing. The torso was rotated onto a wood block to intubate the aorta through a left thoracotomy incision. The thoracic aorta

  16. Lotus birth, a holistic approach on physiological cord clamping.

    Science.gov (United States)

    Zinsser, Laura A

    2017-09-04

    The positive effects of delayed cord clamping (DCC) has been extensively researched. DCC means: waiting at least one minute after birth before clamping and cutting the cord or till the pulsation has stopped. With physiological clamping and cutting (PCC) the clamping and cutting can happen at the earliest after the pulsation has stopped. With a Lotus birth, no clamping and cutting of the cord is done. A woman called Clair Lotus Day imitated the holistic approach of PCC from an anthropoid ape in 1974. The chimpanzee did not separate the placenta from the newborn. The aim of this case report is to discuss and learn a different approach in the third stage of labour. Three cases of Lotus birth by human beings were observed. All three women gave birth in an out-of-hospital setting and had ambulant postnatal care. The placenta was washed, salted and herbs were put on 2-3h post partum. The placenta was wrapped in something that absorbs the moisture. The salting was repeated with a degreasing frequency depending on moistness of the placenta. On life day six all three Lotus babies experiences a natural separation of the cord. All three Lotus birth cases were unproblematic, no special incidence occurred. One should differentiate between early cord clamping (ECC), delayed cord clamping (DCC) and physiological cord clamping (PCC). Lotus birth might lead to an optimisation of the bonding and attachment. Research is needed in the areas of both PCC and Lotus birth. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  17. Voltage stability evaluation facing small disturbances by means of the modal analysis technique; Evaluacion de la estabilidad de voltaje ante disturbios pequenos mediante la tecnica de analisis modal

    Energy Technology Data Exchange (ETDEWEB)

    Leon Rodriguez, Daniel

    2000-12-15

    The economic development of the countries has taken implicit a growing industrialization the one which, joined to those every time bigger resident's necessities, it has caused a constant and progressive increment in the electric power demand. However, in the last years the growth of the electric network of these systems has been more and more limited for diverse such factors as the ecology and the economy, as well as for the social and political costs that implies each new construction in the system. With the presence of these restrictions the electric systems in many cases, have been forced to satisfy the increments in the demand making a more exhaustive use of the infrastructure that they have available and the incorporation of only a few new system elements or constructions. These aspects have caused such systems to operate with more limited security margins and that their stability has to be analyzed in a reliable and precise way. Taking into account the previously mentioned aspects, as the electric systems have had the necessity of operating under forced conditions to satisfy the load demand, voltage stability problems have been presented with more frequency causing serious disturbances and in some cases, total blackouts. With these problems, the voltage stability analysis has taken bigger importance in the studies that the electric utilities carry out. This issue has caused that bigger resources are dedicated for the investigation of this phenomenon with the purpose of understanding and developing tools that allow studying it in a more complete and more truthful way. Modal analysis is one of the most recent and popular steady techniques the one that, from its appearance has had a great peak due to the valuable and quick information that provides, besides its implementation easiness and the little effort computational that it requires. In this work is carried out the voltage stability evaluation of a real electric system applying in a combined way the

  18. Numerical Electric Field Analysis of Power Status Sensor Observing Power Distribution System Taking into Account Voltage Divider Measurement Circuit

    Science.gov (United States)

    Kubo, Takuro; Furukawa, Tatsuya; Itoh, Hideaki; Fukumoto, Hisao; Wakuya, Hiroshi; Ohchi, Masashi

    We have proposed and preproducted the voltage-current waveform sensor of resin molded type for measuring the power factor and harmonics in power distribution systems. We have executed numerical electromagnetic analyses using the finite element method to estimate the characteristics and behaviours of the sensor. Although the magnetic field analyses for the current sensor have involved the measurement circuit, the electric field analyses have not included the measurement circuit for measuring voltage waveforms of power lines. In this paper, we describe the electric field analyses with the measurement circuit and prove the insulating strength of the proposed sensor permissible to the use in 22kV power distribution systems.

  19. Gating of the two-pore cation channel AtTPC1 in the plant vacuole is based on a single voltage-sensing domain.

    Science.gov (United States)

    Jaślan, D; Mueller, T D; Becker, D; Schultz, J; Cuin, T A; Marten, I; Dreyer, I; Schönknecht, G; Hedrich, R

    2016-09-01

    The two-pore cation channel TPC1 operates as a dimeric channel in animal and plant endomembranes. Each subunit consists of two homologous Shaker-like halves, with 12 transmembrane domains in total (S1-S6, S7-S12). In plants, TPC1 channels reside in the vacuolar membrane, and upon voltage stimulation, give rise to the well-known slow-activating SV currents. Here, we combined bioinformatics, structure modelling, site-directed mutagenesis, and in planta patch clamp studies to elucidate the molecular mechanisms of voltage-dependent channel gating in TPC1 in its native plant background. Structure-function analysis of the Arabidopsis TPC1 channel in planta confirmed that helix S10 operates as the major voltage-sensing site, with Glu450 and Glu478 identified as possible ion-pair partners for voltage-sensing Arg537. The contribution of helix S4 to voltage sensing was found to be negligible. Several conserved negative residues on the luminal site contribute to calcium binding, stabilizing the closed channel. During evolution of plant TPC1s from two separate Shaker-like domains, the voltage-sensing function in the N-terminal Shaker-unit (S1-S4) vanished.

  20. Whole-cell recordings of voltage-gated Calcium, Potassium and Sodium currents in acutely isolated hippocampal pyramidal neurons

    Institute of Scientific and Technical Information of China (English)

    Shuyun Huang; Qing Cai; Weitian Liu; Xiaoling Wang; Tao Wang

    2009-01-01

    Objective:To record Calcium, Potassium and Sodium currents in acutely isolated hippocampal pyramidal neurons. Methods:Hip-pocampal CA3 neurons were freshly isolated by 1 mg protease/3 ml SES and mechanical trituration with polished pipettes of progressively smaller tip diameters. Patch clamp technique in whole-cell mode was employed to record voltage-gated channel currents. Results:The procedure dissociated hippocampal neurons, preserving apical dendrites and several basal dendrites, without impairing the electrical characteristics of the neurons. Whole-cell patch clamp configuration was successfully used to record voltage-gated Ca2+ currents, delayed rectifier K+ current and voltage-gated Na+ currents. Conclusion:Protease combined with mechanical trituration may be used for the dissociation of neurons from rat hippocampus. Voltage-gated channels currents could be recorded using a patch clamp technique.

  1. Enhanced Dynamic Voltage Stability Support by VSC-HVDC for Offshore Wind Applications using Trajectory Sensitivity Analysis

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe; Liu, Leo

    2013-01-01

    . In this paper, VSC-HVDC transmission system is used to integrate a large-scale wind power plant into the onshore power grid. For different voltage support strategies of VSC-HVDC, a trajectory sensitivity analysisbased approach is proposed to find the minimum onshore VSC capacity with which the VSC-HVDC can...

  2. Thermal Analysis of Multilevel Grid-side Converters for 10-MW Wind turbines under Low-Voltage Ride Through

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede; Liserre, Marco

    2013-01-01

    designed as case study. The operation status, as well as the reliability-related performances, is investigated aimed at various low-voltage ride through (LVRT) conditions. It is found that all of the proposed converter topologies will suffer from higher junction temperature in some heavily loaded power...

  3. Fault identification in crystalline silicon PV modules by complementary analysis of the light and dark current-voltage characteristics

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Sera, Dezso; Hacke, Peter

    2014-01-01

    Photovoltaic system (PV) maintenance and diagnostic tools are often based on performance models of the system, complemented with light current-voltage (I-V) measurements, visual inspection and/or thermal imaging. Although these are invaluable tools in diagnosing PV system performance losses and f...

  4. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping) improves systemic and cerebral oxygenation in preterm lambs.

    Science.gov (United States)

    Polglase, Graeme R; Dawson, Jennifer A; Kluckow, Martin; Gill, Andrew W; Davis, Peter G; Te Pas, Arjan B; Crossley, Kelly J; McDougall, Annie; Wallace, Euan M; Hooper, Stuart B

    2015-01-01

    As measurement of arterial oxygen saturation (SpO2) is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known. We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs. Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2) were measured continuously in apnoeic preterm lambs (126±1 day gestation). Positive pressure ventilation was initiated either 1) prior to umbilical cord clamping, or 2) after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping. Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping. The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  5. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping improves systemic and cerebral oxygenation in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Graeme R Polglase

    Full Text Available As measurement of arterial oxygen saturation (SpO2 is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known.We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs.Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2 were measured continuously in apnoeic preterm lambs (126±1 day gestation. Positive pressure ventilation was initiated either 1 prior to umbilical cord clamping, or 2 after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping.Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping.The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  6. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  7. Analysis of three-phase rectifiers with AC-side switches and interleaved three-phase voltage-source converters

    Science.gov (United States)

    Miller, Stephanie Katherine Teixeira

    Of all the alternative and renewable energy sources, wind power is the fastest growing alternative energy source with a total worldwide capacity of over 93 GW as of the end of 2007. However, making wind energy a sustainable and reliable source of electricity doesn't come without its set of challenges. As the wind turbines increase in size and turbine technology moves towards off-shore wind farms and direct drive transmission, the need for a reliable and efficient power electronics interface to convert the variable-frequency variable-magnitude output of the wind turbine's generator into the fixed-frequency fixed-magnitude voltage of the utility grid is critical. This dissertation investigates a power electronics interface envisioned to operate with an induction generator-based variable-speed wind turbine. The research conclusions and the interface itself are applicable to a variety of applications, including uninterruptible power supplies, industrial drives, and power quality applications, among others. The three-phase PWM rectifiers with ac-side bidirectional switches are proposed as the rectification stage of the power electronics interface. Modulation strategies are proposed for the rectifiers and the operation of the rectifiers in conjunction with an induction generator is demonstrated. The viability of using these rectifiers in place of the standard three-phase voltage-source converter is analyzed by comparing losses and common-mode voltage generation of the two topologies. Parallel three-phase voltage-source converter modules operated in an interleaved fashion are proposed for the inversion stage of the power electronics interface. The interleaved three-phase voltage-source converters are analyzed by deriving analytical models for the common-mode voltage, ac phase current, and dc-link current to reveal their spectra and the harmonic cancellation effects of interleaving. The practical problem of low frequency circulating current in parallel voltage

  8. Engineering of a Genetically Encodable Fluorescent Voltage Sensor Exploiting Fast Ci-VSP Voltage-Sensing Movements

    OpenAIRE

    Alicia Lundby; Hiroki Mutoh; Dimitar Dimitrov; Walther Akemann; Thomas Knöpfel

    2008-01-01

    Ci-VSP contains a voltage-sensing domain (VSD) homologous to that of voltage-gated potassium channels. Using charge displacement ('gating' current) measurements we show that voltage-sensing movements of this VSD can occur within 1 ms in mammalian membranes. Our analysis lead to development of a genetically encodable fluorescent protein voltage sensor (VSFP) in which the fast, voltage-dependent conformational changes of the Ci-VSP voltage sensor are transduced to similarly fast fluorescence re...

  9. Harmonic Analysis and Elimination Strategy for Voltage Source Converter Under Unbalanced Three-phase Voltage%不对称三相电压下电压源型换流器谐波分析与抑制策略

    Institute of Scientific and Technical Information of China (English)

    钟庆; 黄凯; 王钢; 张尧

    2014-01-01

    不对称三相电压下,电压源型换流器(VSC)将产生低次谐波,给电网造成谐波污染。随着VSC在电力系统中的广泛应用,这类问题必须得到更多的关注,提出有效的解决方法。基于动态相量和序分量,推导出序分量动态相量,并对其特性进行了分析;将含开关函数描述的VSC时域模型转化为动态相量模型;定义交流电流和直流电压的各阶序分量动态相量为状态变量,建立了以状态空间描述的VSC序分量动态相量谐波分析模型,综合考虑了开关函数的详细动态特性和交直流侧谐波的相互作用,从而揭示了 VSC 产生谐波的机理,实现了 VSC 谐波的解析求解。在此基础上,提出负序补偿的不对称调制策略,以抑制低次谐波的产生。通过各种不对称情况下的仿真和计算,验证了所提出的谐波分析模型的正确性和谐波抑制策略的有效性。%A voltage source converter (VSC) will generate low-order harmonics under unbalanced three-phase voltage causing harmonic pollution to power grids.With the wide application of VSCs in power systems,the harmonic pollution must be eliminated and given more attention by finding effective solutions.Based on dynamic phasors and symmetrical components,the sequence dynamic phasor is deduced and its characteristics are analyzed.The time domain VSC model containing a description of switching function is transformed into a dynamic phasor model.By setting the sequence dynamic phasors of AC current and DC voltage as the state variables,a harmonic analysis model in the state space based on the sequence dynamic phasors of VSC is developed.The model considers both the dynamic performance of power electronic devices and the interaction between AC and DC sides thus revealing the mechanism of how VSC generates harmonics.Based on the model,the harmonics generated by VSC can be calculated analytically.A harmonic elimination strategy with an

  10. NUMERICAL ANALYSIS OF MATHEMATICAL MODELS OF THE FACTUAL CONTRIBUTION DISTRIBUTION IN ASYMMETRY AND DEVIATION OF VOLTAGE AT THE COMMON COUPLING POINTS OF ENERGY SUPPLY SYSTEMS

    Directory of Open Access Journals (Sweden)

    Yu.L. Sayenko

    2016-05-01

    Full Text Available Purpose. Perform numerical analysis of the distribution of the factual contributions of line sources of distortion in the voltage distortion at the point of common coupling, based on the principles of superposition and exclusions. Methodology. Numerical analysis was performed on the results of the simulation steady state operation of power supply system of seven electricity consumers. Results. Mathematical model for determining the factual contribution of line sources of distortion in the voltage distortion at the point of common coupling, based on the principles of superposition and exclusions, are equivalent. To assess the degree of participation of each source of distortion in the voltage distortion at the point of common coupling and distribution of financial compensation to the injured party by all sources of distortion developed a one-dimensional criteria based on the scalar product of vectors. Not accounting group sources of distortion, which belong to the subject of the energy market, to determine their total factual contribution as the residual of the factual contribution between all sources of distortion. Originality. Simulation mode power supply system was carried out in the phase components space, taking into account the distributed characteristics of distortion sources. Practical value. The results of research can be used to develop methods and tools for distributed measurement and analytical systems assessment of the power quality.

  11. Analysis of GIS data to investigate natural resource impacts of high-voltage overhead lines in the examples in Lower Saxony and North Rhine-Westphalia

    Energy Technology Data Exchange (ETDEWEB)

    Thinh, Nguyen Xuan; Sander, Leon; Kopec, Jakob; Muehlnickel, Kai [Technische Univ. Dortmund (Germany). Dept. of Spatial Information Management and Modelling

    2013-07-01

    In this paper we describe shortly Lower Saxony and North Rhine-Westphalia as study areas and the legal framework, both in the context of natural resource impacts of high-voltage overhead lines. We then conduct the buffer analysis of a GIS dataset in order to investigate natural resource impacts of existing high-voltage overhead lines in the two mentioned study areas. The paper is based upon the first results of the interdisciplinary research and development project ''Power Network Planning'' funded as part of the 6th Energy research program ''Research for an environmentally friendly, reliable and affordable energy supply'' by the German Federal Ministry of Economics and Technology (BMWi). (orig.)

  12. Static DC to DC Power Conditioning-Active Ripple Filter, 1 MHZ DC to DC Conversion, and Nonlinear Analysis. Ph.D. Thesis; [voltage regulation and conversion circuitry for spacecraft power supplies

    Science.gov (United States)

    Sander, W. A., III

    1973-01-01

    Dc to dc static power conditioning systems on unmanned spacecraft have as their inputs highly fluctuating dc voltages which they condition to regulated dc voltages. These input voltages may be less than or greater than the desired regulated voltages. The design of two circuits which address specific problems in the design of these power conditioning systems and a nonlinear analysis of one of the circuits are discussed. The first circuit design is for a nondissipative active ripple filter which uses an operational amplifier to amplify and cancel the sensed ripple voltage. A dc to dc converter operating at a switching frequency of 1 MHz is the second circuit discussed. A nonlinear analysis of the type of dc to dc converter utilized in designing the 1 MHz converter is included.

  13. 基于动态响应的电压稳定分析方法%Analysis Method of Voltage Stability based on Dynamic Response

    Institute of Scientific and Technical Information of China (English)

    王亚俊; 吴佳军; 云雷; 王乙斐; 马志昊; 邵雅宁

    2013-01-01

    As modern power system is pushed to the maximum operation condition, system voltage stability becomes a significant issue. It is necessary to find out a precise and reliable method to analyze voltage stability. This paper presents a method which is based on the dynamic response theory. This method can analyze stability accurately by calculating Thevenin equivalent parameters and judging the status of voltage stability. The outcomes of IEEE 9-bus power system simulation have confirmed the validity and effectiveness of the method. Under the trend of on-line analysis, this method is of certain significance to on line analysis of voltage stability.%随着电力系统的运行越来越接近其极限状态,电力系统电压稳定问题日益突出,研究一种精确可靠的电压稳定分析方法是非常必要的.提出了一种基于动态响应的电压稳定分析方法,该方法通过计算戴维南等值参数及确定电压稳定判据可以精确实现电压稳定分析.IEEE 9节点算例仿真验证了该方法的正确性和有效性.当在线分析成为趋势的时候,该方法对实现电压稳定的在线分析有一定的现实意义.

  14. Novel Full-bridge ZVS DC-DC Converter with an Clamp Diodes

    Science.gov (United States)

    Guangqun, Nan; Xue, Hu

    The two arms of this converter all work at zero-voltage switching condition, that bring many advantages, such as little loss of power, simple control, etc. But these also exists some problems, such as parasitic oscillation on the output rectifier diodes. A novel full-bridge ZVS PWM DC-DC converter which adopts two clamping diodes in the first side of the transformer is proposed to reduce the parasitic oscillation in this paper. In this paper, It heavily analyzes the realization process of their soft-switching and the reason of related issues and solution, we establishes simulation model and simulates using orCAD. Finally,a 5 kW ZVS PWM DC-DC converter Prototype in that TMS320F2812 is the core controlled chip has been set up, and the experiments showed us the validation of the correlative theory.

  15. SIMPLIFIED SVPWM ALGORITHM BASED DIODE CLAMPED 3-LEVEL INVERTER FED DTC-IM DRIVE

    Directory of Open Access Journals (Sweden)

    C. HARI KRISHNA

    2012-05-01

    Full Text Available This paper presents a simplified space vector pulse width modulation (SVPWM based diode clamped threelevel inverter fed direct torque controlled (DTC induction motor drive. The space vector diagram of three-level inverter is simplified into two-level inverter. So the selection of switching sequences is done as conventional two-level SVPWM method. Thus, the proposed algorithm reduces the complexity involved in the PWM algorithm. To validate the proposed PWM lgorithm, several simulation studies have been carried and resultsare presented. From the results, it can be observed that the proposed algorithm reduces the total harmonic distortion (THD of the line current and line voltages when compared with the 2-level inverter fed induction motor drive.

  16. Harmonic Mitigated Front End Three Level Diode Clamped High Frequency Link Inverter by Using MCI Technique

    Directory of Open Access Journals (Sweden)

    Sreedhar Madichetty

    2014-02-01

    Full Text Available In this paper it proposes a high efficient soft-switching scheme based on zero-voltage-switching (ZVS and zero-current-switching(ZCS principle operated with a simple auxiliary circuit extended range for the front-end isolated DC-AC-DC-AC high power converter with an three phase three level diode clamped multi level inverter by using Minority Charge Carrier inspired optimization technique (MCI with Total Harmonic Distortion(THD,Switching losses, Selective harmonic elimination maintaining with its fundamental as an objective function. Input to the inverter is obtained by the photo voltaic cells and with battery bank. The switching scheme is optimized by MCI technique, analyzed and executed in Matlab and implemented with a digital signal processor (DSP .Experimental results with different loads have observed and shows its effectives, robustness of the applied technique.

  17. Improving the transient response of a bolt-clamped Langevin transducer using a parallel resistor.

    Science.gov (United States)

    Chang, Kuo Tsi

    2003-08-01

    This paper suggests a parallel resistor to reduce DC time constant and DC response time of the transient response, induced immediately after an AC voltage connected to a bolt-clamped Langevin transducer (BLT) is switched off. An equivalent circuit is first expressed. Then, an open-circuit transient response at the terminals induced by initial states is derived and measured, and thus parameters for losses of the BLT device are estimated by DC and AC time constants of the transient response. Moreover, a driving and measuring system is designed to determine transient response and steady-state responses of the BLT device, and a parallel resistor is connected to the BLT device to reduce the DC time constant. Experimental results indicate that the DC time constant greatly exceeds the AC time constant without the parallel resistor, and greatly decreases from 42 to 1 ms by a 100-kOmega parallel resistor.

  18. A Color LED Driver Implemented by the Active Clamp Forward Converter

    Directory of Open Access Journals (Sweden)

    C. H. Chang

    2013-03-01

    Full Text Available Because light emitting diodes (LEDs have the advantages of dc working voltage, high luminescent efficiency, shortignition time, high reliability and pollution free, they have substituted for incandescent bulbs and fluorescent lampsgradually. In order to simplify circuit complexity, an active clamp forward converter with the sequential color display(SCD control is proposed to drive red, green and blue (RGB LED arrays. The proposed converter has zero-voltageswitching (ZVS operations of both the main switch and the auxiliary switch, resulting in high system efficiency. DrivingRGB LED arrays sequentially by one converter can save components and reduce cost significantly. Additionally, thepulse-width modulation (PWM control is applied to achieve a large chromaticity variation. The circuit operations areanalyzed in detail and the circuit parameters are designed based on the practical considerations. Finally, an illustrativeexample is implemented to demonstrate the feasibility and validity of the proposed LED driver.

  19. Comparative Evaluation of Pulsewidth Modulation Strategies for Z-Source Neutral-Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Wong, C.P.

    2007-01-01

    modulation (PWM) strategies for controlling the Z-source NPC inverter. While developing the PWM techniques, attention has been devoted to carefully derive them from a common generic basis for improved portability, easier implementation, and most importantly, assisting readers in understanding all concepts......Z-source neutral-point-clamped (NPC) inverter has recently been proposed as an alternative three-level buck-boost power conversion solution with an improved output waveform quality. In principle, the designed Z-source inverter functions by selectively "shooting through" its power sources, coupled...... to the inverter using two unique Z-source impedance networks, to boost the inverter three-level output waveform. Proper modulation of the new inverter would therefore require careful integration of the selective shoot-through process to the basic switching concepts to achieve maximal voltage-boost, minimal...

  20. Comparative Evaluation of Pulsewidth Modulation Strategies for Z-Source Neutral-Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Wong, C.P.

    2007-01-01

    Z-source neutral-point-clamped (NPC) inverter has recently been proposed as an alternative three-level buck-boost power conversion solution with an improved output waveform quality. In principle, the designed Z-source inverter functions by selectively "shooting through" its power sources, coupled...... to the inverter using two unique Z-source impedance networks, to boost the inverter three-level output waveform. Proper modulation of the new inverter would therefore require careful integration of the selective shoot-through process to the basic switching concepts to achieve maximal voltage-boost, minimal...... that have been presented. The presented strategies are also comparatively evaluated to identify their individual advantages and disadvantages, which are subsequently summarized in a comprehensive reference table. Last, simulation and experimental results are included for validating the performances...

  1. Model Predictive Control of Z-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    2011-01-01

    This paper presents Model Predictive Control (MPC) of Z-source Neutral Point Clamped (NPC) inverter. For illustration, current control of Z-source NPC grid-connected inverter is analyzed and simulated. With MPC’s advantage of easily including system constraints, load current, impedance network...... inductor current, capacitor voltage as well as switching frequency, transient response are all regulated as subjecting to constraints of this control method. The quality of output waveform, stability of impedance-network, level constraint of variable switching frequency as well as robustness of transient...... response are obtained at the same time with a formulated Z-source NPC inverter network model. Operation steady state and transient state simulation results of MPC are going to be presented, which shows good reference tracking ability of this method. It provides new control method for Z-source NPC inverter...

  2. Transient Voltage Recorder

    Science.gov (United States)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    2002-01-01

    A voltage transient recorder can detect lightning induced transient voltages. The recorder detects a lightning induced transient voltage and adjusts input amplifiers to accurately record transient voltage magnitudes. The recorder stores voltage data from numerous monitored channels, or devices. The data is time stamped and can be output in real time, or stored for later retrieval. The transient recorder, in one embodiment, includes an analog-to-digital converter and a voltage threshold detector. When an input voltage exceeds a pre-determined voltage threshold, the recorder stores the incoming voltage magnitude and time of arrival. The recorder also determines if its input amplifier circuits clip the incoming signal or if the incoming signal is too low. If the input data is clipped or too low, the recorder adjusts the gain of the amplifier circuits to accurately acquire subsequent components of the lightning induced transients.

  3. Surface-charge accumulation effects on open-circuit voltage in organic solar cells based on photoinduced impedance analysis.

    Science.gov (United States)

    Zang, Huidong; Hsiao, Yu-Che; Hu, Bin

    2014-03-14

    The accumulation of dissociated charge carriers plays an important role in reducing the loss occurring in organic solar cells. We find from light-assisted capacitance measurements that the charge accumulation inevitably occurred at the electrode and photovoltaic layer interface for bulk-heterojunction ITO/PEDOT:PSS/P3HT:PCBM/Ca/Al solar cells. Our results indicate, for the first time through impedance measurements, that the charge accumulation exists at the anode side of the device, and more importantly, we successfully identify the type of charge accumulated. Further study shows that the charge accumulation can significantly affect open circuit voltage and short circuit current. As a result, our experimental results from light assisted capacitance measurements provide a new understanding of the loss in open-circuit voltage and short-circuit photocurrent based on charge accumulation. Clearly, controlling charge accumulation presents a new mechanism to improve the photovoltaic performance of organic solar cells.

  4. Analysis of a three-part 230 kV optical voltage transducer with multiple electric field sensors

    Energy Technology Data Exchange (ETDEWEB)

    Namedanian, M.; Mozafari, M.; Razavi, S. [Niroo Research Inst., Tehran (Iran, Islamic Republic of). Dept. of Electronics, Control and Instrumentation

    2008-07-01

    A 3-part optical voltage transducer (OVT) was used as a replacement for conventional inductive and capacitive transformers. A quadrature method was used to position the sensors. The OVT was designed using a finite element simulation program with a particle swarm optimization (PSO) algorithm. Each section of the 3-part insulator consisted of a fiberglass tube with silicon rubber shedding. A corona ring was positioned around the top of the insulator. The simulations were conducted to demonstrate various perturbation scenarios and examine the potential distorted behaviour of the electric field. Ratio errors and voltage differences occurring from the various perturbations were calculated in order to determine the optimal positions and weights of the OVT. Results of the study indicated that the OVT will meet all standard requirements and be cheaper and easier to implement than conventional capacitive or inductive transformers. 8 refs., 3 tabs., 5 figs.

  5. A new model analysis of the third harmonic voltage in inductive measurement for critical current density of superconducting films

    Institute of Scientific and Technical Information of China (English)

    Zhang Xu; Wu Zhi-Zhen; Zhou Tie-Ge; He Ming; Zhao Xin-Jie; Yan Shao-Lin; Fang Lan

    2011-01-01

    The critical current density Jc is one of the most important parameters of high temperature superconducting films in superconducting applications, such as superconducting filter and superconducting Josephson devices. This paper presents a new model to describe inhomogeneous current distribution throughout the thickness of superconducting films applying magnetic field by solving the differential equation derived from Maxwell equation and the second London equation. Using this model, it accurately calculates the inductive third-harmonic voltage when the film applying magnetic field with the inductive measurement for Jc. The theoretic curve is consistent with the experimental results about measuring superconducting film, especially when the third-harmonic voltage just exceeds zero. The Jc value of superconducting films determined by the inductive method is also compared with results measured by four-probe transport method. The agreements between inductive method and transport method are very good.

  6. Adverse impact of intermittent portal clamping on long-term postoperative outcomes in hepatocellular carcinoma.

    Science.gov (United States)

    Hao, S; Chen, S; Yang, X; Wan, C

    2017-01-01

    Introduction To evaluate the impact of intermittent portal clamping (IPC) on long-term postoperative outcomes in patients with hepatocellular carcinoma (HCC). Methods Clinical records of 355 patients underwent curative liver resection for HCC in January 2007 to December 2010 were retrospectively reviewed. According to how portal clamping was performed, patients were grouped as: IPC, n=113; other portal clamping (OPC), n=190; and no portal clamping (NPC), n=52. Results Median recurrence-free survival (RFS) was statistically significantly shorter in the IPC (39.4 months) than OPC (47.3 months, p=0.010) and NPC groups (51.4 months, p=0.008). Median overall survival (OS) was also significantly shorter with IPC (46.3 months), versus 52.9 months with OPC (p=0.022) and 56.2 months with NPC (p=0.015). Kaplan-Meier survival analysis revealed that 5-year cumulative RFS was much lower in the IPC (42.5%) than OPC (50.9%, p=0.014) and NPC groups (49.6%, p=0.013). Five-year cumulative OS was also much lower in the IPC (44.9%) than OPC (58.0%, p=0.020) and NPC groups (57.7%, p=0.025). On univariate analysis, tumour grade, size and number, TNM stage, blood transfusion, vascular invasion and IPC were significantly inversely correlated with RFS and OS. On multivariate analysis, tumour size and number, blood transfusion, vascular invasion and IPC remained significant. Conclusions Our study suggests that IPC is an independent risk factor for poor long-term postoperative outcomes in patients with HCC.

  7. Screening fluorescent voltage indicators with spontaneously spiking HEK cells.

    Directory of Open Access Journals (Sweden)

    Jeehae Park

    Full Text Available Development of improved fluorescent voltage indicators is a key challenge in neuroscience, but progress has been hampered by the low throughput of patch-clamp characterization. We introduce a line of non-fluorescent HEK cells that stably express NaV 1.3 and KIR 2.1 and generate spontaneous electrical action potentials. These cells enable rapid, electrode-free screening of speed and sensitivity of voltage sensitive dyes or fluorescent proteins on a standard fluorescence microscope. We screened a small library of mutants of archaerhodopsin 3 (Arch in spiking HEK cells and identified two mutants with greater voltage-sensitivity than found in previously published Arch voltage indicators.

  8. Data processing of high-rate low-voltage distribution grid recordings for smart grid monitoring and analysis

    Science.gov (United States)

    Maaß, Heiko; Cakmak, Hüseyin Kemal; Bach, Felix; Mikut, Ralf; Harrabi, Aymen; Süß, Wolfgang; Jakob, Wilfried; Stucky, Karl-Uwe; Kühnapfel, Uwe G.; Hagenmeyer, Veit

    2015-12-01

    Power networks will change from a rigid hierarchic architecture to dynamic interconnected smart grids. In traditional power grids, the frequency is the controlled quantity to maintain supply and load power balance. Thereby, high rotating mass inertia ensures for stability. In the future, system stability will have to rely more on real-time measurements and sophisticated control, especially when integrating fluctuating renewable power sources or high-load consumers like electrical vehicles to the low-voltage distribution grid.

  9. Circuit-field coupled finite element analysis method for an electromagnetic acoustic transducer under pulsed voltage excitation

    Institute of Scientific and Technical Information of China (English)

    Hao Kuan-Sheng; Huang Song-Ling; Zhao Wei; Wang Shen

    2011-01-01

    This paper presents an analytical method for electromagnetic acoustic transducers (EMATs) under voltage excitation and considers the non-uniform distribution of the biased magnetic field. A complete model of EMATs including the non-uniform biased magnetic field, a pulsed eddy current field and the acoustic field is built up. The pulsed voltage excitation is transformed to the frequency domain by fast Fourier transformation (FFT). In terms of the time harmonic field equations of the EMAT system, the impedances of the coils under different frequencies are calculated according to the circuit-field coupling method and Poynting's theorem. Then the currents under different frequencies are calculated according to Ohm's law and the pulsed current excitation is obtained by inverse fast Fourier transformation (IFFT).Lastly, the sequentially coupled finite element method (FEM) is used to calculate the Lorentz force in the EMATs under the current excitation. An actual EMAT with a two-layer two-bundle printed circuit board (PCB) coil, a rectangular permanent magnet and an aluminium specimen is analysed. The coil impedances and the pulsed current are calculated and compared with the experimental results. Their agreement verified the validity of the proposed method. Furthermore, the influences of lift-off distances and the non-uniform static nagnetic field on the Lorentz force under pulsed voltage excitation are studied.

  10. A self-strain feedback tuning-fork-shaped ionic polymer metal composite clamping actuator with soft matter elasticity-detecting capability for biomedical applications.

    Science.gov (United States)

    Feng, Guo-Hua; Huang, Wei-Lun

    2014-12-01

    This paper presents a smart tuning-fork-shaped ionic polymer metal composite (IPMC) clamping actuator for biomedical applications. The two fingers of the actuator, which perform the clamping motion, can be electrically controlled through a unique electrode design on the IPMC material. The generated displacement or strain of the fingers can be sensed using an integrated soft strain-gage sensor. The IPMC actuator and associated soft strain gage were fabricated using a micromachining technique. A 13.5×4×2 mm(3) actuator was shaped from Nafion solution and a selectively grown metal electrode formed the active region. The strain gage consisted of patterned copper foil and polyethylene as a substrate. The relationship between the strain gage voltage output and the displacement at the front end of the actuator's fingers was characterized. The equivalent Young's modulus, 13.65 MPa, of the soft-strain-gage-integrated IPMC finger was analyzed. The produced clamping force exhibited a linear increasing rate of 1.07 mN/s, based on a dc driving voltage of 7 V. Using the developed actuator to clamp soft matter and simultaneously acquire its Young's modulus was achieved. This demonstrated the feasibility of the palpation function and the potential use of the actuator in minimally invasive surgery.

  11. A comparative study of the action of tolperisone on seven different voltage dependent sodium channel isoforms.

    Science.gov (United States)

    Hofer, Doris; Lohberger, Birgit; Steinecker, Bibiane; Schmidt, Kurt; Quasthoff, Stefan; Schreibmayer, Wolfgang

    2006-05-24

    The specific, acute interaction of tolperisone, an agent used as a muscle relaxant and for the treatment of chronic pain conditions, with the Na(v1.2), Na(v1.3), Na(v1.4), Na(v1.5), Na(v1.6), Na(v1.7), and Na(v1.8) isoforms of voltage dependent sodium channels was investigated and compared to that of lidocaine. Voltage dependent sodium channels were expressed in the Xenopus laevis oocyte expression system and sodium currents were recorded with the two electrode voltage clamp technique. Cumulative dose response relations revealed marked differences in IC(50) values between the two drugs on identical isoforms, as well as between isoforms. A detailed kinetic analysis uncovered that tolperisone as well as lidocaine exhibited their blocking action not only via state dependent association/dissociation with voltage dependent sodium channels, but a considerable fraction of inhibition is tonic, i.e. permanent and basic in nature. Voltage dependent activation was affected to a minor extent only. A shift in steady-state inactivation to more negative potentials could be observed for most drug/isoform combinations. The contribution of this shift to overall block was, however, small at drug concentrations resulting in considerable overall block. Recovery from inactivation was affected notably by both drugs. Lidocaine application led to a pronounced prolongation of the time constant of the fast recovery process for the Na(v1.3), Na(v1.5), and Na(v1.7) isoforms, indicating common structural properties in the local anesthetic receptor site of these three proteins. Interestingly, this characteristic drug action was not observed for tolperisone.

  12. Speed Control Of Separately Excited Dc Motor Using A High Efficiency Flyback Converter With New Active Clamp Technique M.Subramanyam*, K.Eswaramma

    Directory of Open Access Journals (Sweden)

    M.Subramanyam

    2014-10-01

    Full Text Available This paper deals with Speed control of separately excited DC motor using flyback converter with a new non complementary active clamp control method to achieve soft switching and high efficiency for heavy motor load and light load conditions. This is quite attractive for low power application with universal ac inputs, such as external adaptors. With the proposed control technique, the energy in the leakage inductance can be fully recycled. The soft switching can be achieved for the main switch and the absorbed leakage energy is transferred to the output and input side. In the Proposed model the resistive and DC motor is connected to flyback converter and it is simulated with different nominal voltages and rated speed is controlled at different levels for the N-type active clamp flyback converter and P-type active clamp flyback converter respectively. N-type active clamp flyback converter is suitable for high speed variation applications and P-type active clamp flyback converter is suitable for low speed variation applications.

  13. Discontinuous PWM Modulation Strategy with Circuit-Level Decoupling Concept of Three-Level Neutral-Point Clamped (NPC) Inverter

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2013-01-01

    A new pulse width modulation (PWM) strategy which is an alternative approach of discontinuous PWM (DPWM) for a three-level neutral point clamped (NPC) inverter is developed and presented in this paper. The proposed PWM scheme not only takes advantage of the special properties available in NPC...... can be simplified. The salient features of the proposed scheme, as compared with the existing carrier-based DPWM strategies, are: 1) its reduced computational processing time, 2) its capability to balance the DC-link voltage without any additional control and 3) its reduced complexity e.g. only one...

  14. ß-adrenergic regulation of ion transport in pancreatic ducts: Patch-clamp study of isolated rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I

    1998-01-01

    much smaller effects. At comparable concentrations, it depolarized Vm by a few millivolts. Neither agonist had significant effects on intracellular Ca2+. CONCLUSIONS: This study provides the first direct evidence that adrenergic stimulation, namely, that of beta-adrenoceptors, controls ion transport....... METHODS: Small intralobular ducts were isolated from rat pancreas and studied in vitro by the whole-cell patch clamp technique. Cell membrane voltages and currents were indicators of cellular ion transport. In some ducts, intracellular Ca2+ activity was measured by fluorescence optical methods. RESULTS...... in pancreatic ducts. Similar to secretin, isoproterenol stimulation leads to opening of luminal Cl- channels, and HCO3- enters the lumen in exchange for Cl-....

  15. Arterial Clamping Increases Central Renal Cryoablation Efficacy: An Animal Study

    DEFF Research Database (Denmark)

    Nonboe, Lasse Larsen; Nielsen, Tommy Kjaergaard; Høyer, Søren;

    2017-01-01

    INTRODUCTION: The minimally invasive treatment of small renal masses with cryoablation has become increasingly widespread during the past 15 years. Studies with long-term follow-up are beginning to emerge, showing good oncological control, however, tumors with a central and endophytic location seem...... to possess an increased risk of treatment failure. Such tumors are likely to be subjected to a high volume of blood giving thermal protection to the cancerous cells. Arterial clamping during freezing might reduce this effect but at the same time subject the kidney to ischemia. The aim of this study...... was to evaluate the effect of renal artery clamping during cryoablation in a porcine survival model. METHODS: Ten Danish Landrace pigs (approximately 40 kg) underwent bilateral laparoscopic cryoablation with clamping of the right renal artery during freezing. The cryoablation consisted of a standard double...

  16. [Advantage of delayed umbilical cord clamping in the newborn infant].

    Science.gov (United States)

    Menget, A; Mougey, C; Thiriez, G; Riethmuller, D

    2013-09-01

    The timing of umbilical cord clamping remains controversial. Although most maternity wards use the early clamping (5-15s), randomized studies and meta-analyses have demonstrated the benefit of delayed clamping for term and preterm newborn infants over the past 10 years. Indeed, placentofetal transfusion of 20-30 ml/kg in 2-3 min improves the iron status of term infants and prevents infant hypochromic anemia. Infant anemia is a public health problem in many developing countries. For preterm newborns, placental transfusion for 45 s or milking the cord for 15 s improves cardiovascular adaptation, with better hemodynamic stability, as well as decreased intraventricular hemorrhages, need for transfusion, and late-onset sepsis. A new look at this symbolic act is needed and professionals need to be persuaded of the importance of the "wait a minute" policy for a better physiological delivery.

  17. Using physiology to guide time to cord clamping.

    Science.gov (United States)

    Kluckow, Martin; Hooper, Stuart B

    2015-08-01

    Immediate clamping and cutting of the umbilical cord at birth has been the accepted standard of care for decades. The physiologic rationale relating umbilical cord clamping (UCC) to the events of the circulatory transition is not considered in arbitrarily recommended cord clamping times. Systematic review of early versus deferred UCC shows significant hemodynamic benefits to the deferred group. Mechanisms for this protective effect are considered in this review. The original concept of a placental transfusion with a volume load and prevention of low cardiac output relies on the physiological end point of the amount of blood transfused. The newer concept of an ordered physiological transition is increasingly supported. This model places aeration of the lungs and an increase in pulmonary blood flow back at the centre of the circulatory transition with timing of UCC being related to establishment of respiration. The need for "physiologically based" UCC is discussed. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  18. 电压闪变分析软件设计与实现%Design and Implementation of the Analysis Software for Voltage Flicker

    Institute of Scientific and Technical Information of China (English)

    董衍旭; 周军; 李竞攀; 尚秋峰

    2011-01-01

    电压波动和闪变是衡量电能质量优劣的重要指标,电压闪变信号的检测现已成为国内外研究的热点.为了更方便、准确地测量电压闪变信号,在LabWindows/CVI环境下设计并实现了一种电压闪变小波分析软件.该设计通过调用动态链接库的方法,实现了LabWindows/CVI与Matlab的混合编程,既提升了虚拟仪器软件的开发效率,又提高了可扩展性;采用开源数据库SQLite3存储数据,进一步降低了系统的内存开销与经济开支.试验结果表明,闪变测量模块的测量精度满足IEC的精度要求.%Voltage fluctuation and flicker are important indexes for judging the superior or inferior quality of the power energy; the detection of voltage flicker signals has become one of the hot researching subjects at home and abroad. In order to measure voltage flicker signals easily and precisely, under LabWindows/CVI environment, the wavelet analysis software for voltage flicker has been designed. In the design, the hybrid programming between Lab Windows/CVI and Matlab is implemented through calling dynamic linkage library. This method enhances the developing efficiency of virtual instrument software, and provides expandable capability. By adopting the open source code database SQIite3 to store data, the memory overhand and economical expenses are reduced in further. The experimental results indicate that the measurement accuracy of flicker measuring module satisfies the requirement of IEC.

  19. Plasma temperature clamping in filamentation laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Harilal, Sivanandan S.; Yeak, J.; Phillips, Mark C.

    2015-10-19

    Ultrafast laser filament induced breakdown spectroscopy is a very promising method for remote material detection. We present characteristics of plasmas generated in a metal target by laser filaments in air. Our measurements show that the temperature of the ablation plasma is clamped along the filamentation channel due to intensity clamping in a filament. Nevertheless, significant changes in radiation intensity are noticeable, and this is essentially due to variation in the number density of emitting atoms. The present results also partly explains the reason for the occurrence of atomic plume during fs LIBS in air compared to long-pulse ns LIBS.

  20. The problem of isotropic rectangular plate with four clamped edges

    Indian Academy of Sciences (India)

    C Erdem İmrak; Ismail Gerdemeli

    2007-06-01

    The examination of the exact solution of the governing equation of the rectangular plate is important for many reasons. This report discusses in exact solution of the governing equation of an isotropic rectangular plate with four clamped edges. A numerical method for clamped isotropic rectangular plate under distributed loads and an exact solution of the governing equation in terms of trigonometric and hyperbolic function are given. Finally, an illustrative example is given and the results are compared with those reported earlier. This method is found to be easier and effective. The results show reasonable agreement with other available results, but with a simpler and practical approach.