WorldWideScience

Sample records for volcano intravascular ultrasound

  1. Intravascular ultrasound

    Science.gov (United States)

    IVUS; Ultrasound - coronary artery; Endovascular ultrasound; Intravascular echocardiography ... A tiny ultrasound wand is attached to the top of a thin tube. This tube is called a catheter. The catheter ...

  2. Harmonic Intravascular Ultrasound

    NARCIS (Netherlands)

    M.E. Frijlink (Martijn)

    2006-01-01

    textabstractMedical ultrasound is a popular imaging modality in cardiology. Harmonic Imaging is a technique that has been shown to increase the image quality of diagnostic ultrasound at frequencies below 10 MHz. However, Intravascular Ultrasound, which is a technique to acoustically investigate arte

  3. Harmonic Intravascular Ultrasound

    NARCIS (Netherlands)

    M.E. Frijlink (Martijn)

    2006-01-01

    textabstractMedical ultrasound is a popular imaging modality in cardiology. Harmonic Imaging is a technique that has been shown to increase the image quality of diagnostic ultrasound at frequencies below 10 MHz. However, Intravascular Ultrasound, which is a technique to acoustically investigate arte

  4. Nonlinear intravascular ultrasound contrast imaging

    NARCIS (Netherlands)

    Goertz, David E.; Frijlink, Martijn E.; de Jong, N.; van der Steen, Antonius F.W.

    2006-01-01

    Nonlinear contrast agent imaging with intravascular ultrasound (IVUS) is investigated using a prototype IVUS system and an experimental small bubble contrast agent. The IVUS system employed a mechanically scanned single element transducer and was operated at a 20 MHz transmit frequency (F20) for

  5. Image and Signal Processing in Intravascular Ultrasound

    NARCIS (Netherlands)

    W. Li (Wenguang)

    1997-01-01

    textabstractIntravascular ultrasound (rvUS) is a new imaging mOdality providing real-time, crosssectional, high-resolution images of the arterial lumen and vessel wall. In contrast to conventional x-ray angiography that only displays silhouette views of the vessel lumen, IVUS imaging permits visuali

  6. Transducer for harmonic intravascular ultrasound imaging

    NARCIS (Netherlands)

    Vos, Hendrik J.; Frijlink, Martijn E.; Droog, E.J.; Goertz, David E.; Blacquiere, Gerrit; Gisolf, Anton; de Jong, N.; van der Steen, Antonius F.W.

    2005-01-01

    A recent study has shown the feasibility of tissue harmonic imaging (THI) using an intravascular ultrasound (IVUS) transducer. This correspondence describes the design, fabrication, and characterization of a THI-optimized piezoelectric transducer with oval aperture of 0.75 mm by 1 mm. The transducer

  7. Mapping intravascular ultrasound controversies in interventional cardiology practice.

    Directory of Open Access Journals (Sweden)

    David Maresca

    Full Text Available Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innovation has been relatively limited. Intravascular ultrasound remains a niche technology; its clinical practice did not vastly expand, except in Japan, where intravascular ultrasound is an appraised tool for guiding percutaneous coronary interventions. In this qualitative research study, we follow scholarship on the sociology of innovation in exploring both the current adoption practices and perspectives on the future of intravascular ultrasound. We conducted a survey of biomedical experts with experience in the technology, the practice, and the commercialization of intravascular ultrasound. The collected information enabled us to map intravascular ultrasound controversies as well as to outline the dynamics of the international network of experts that generates intravascular ultrasound innovations and uses intravascular ultrasound technologies. While the technology is praised for its capacity to measure coronary atherosclerotic plaque morphology and is steadily used in clinical research, the lack of demonstrated benefits of intravascular ultrasound guided coronary interventions emerges as the strongest factor that prevents its expansion. Furthermore, most of the controversies identified were external to intravascular ultrasound technology itself, meaning that decision making at the industrial, financial and regulatory levels are likely to determine the future of intravascular ultrasound. In light of opinions from the responding experts', a wider adoption of intravascular ultrasound as a stand-alone imaging modality seems rather uncertain, but the appeal for this technology may be renewed by improving image quality and through combination with

  8. Mapping Intravascular Ultrasound Controversies in Interventional Cardiology Practice

    NARCIS (Netherlands)

    Maresca, D.; Adams, S.; Maresca, B.; Van der Steen, A.F.W.

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innova

  9. Fast integrated intravascular photoacoustic/ultrasound catheter

    Science.gov (United States)

    Choi, Changhoon; Cho, Seunghee; Kim, Taehoon; Park, Sungjo; Park, Hyoeun; Kim, Jinmoo; Lee, Seunghoon; Kang, Yeonsu; Jang, Kiyuk; Kim, Chulhong

    2016-03-01

    In cardiology, a vulnerable plaque is considered to be a key subject because it is strongly related to atherosclerosis and acute myocardial infarction. Because conventional intravascular imaging devices exhibit several limitations with regard to vulnerable plaque detection, the need for an effective lipid imaging modality has been continuously suggested. Photoacoustic (PA) imaging is a medical imaging technique with a high level of ultrasound (US) resolution and strong optical contrast. In this study, we successfully developed an integrated intravascular photoacoustic/ultrasound (IV-PAUS) imaging system with a catheter diameter of 1.2 mm for lipid-rich atherosclerosis imaging. An Nd:YAG pulsed laser with an excitation wavelength of 1064 nm was utilized. IV-PAUS offers 5-mm depth penetration and axial and lateral PA imaging resolutions of 94 μm and 203 μm, respectively, as determined by imaging a 6-μm carbon fiber. We initially obtained 3-dimensional (3D) co-registered PA/US images of metal stents. Subsequently, we successfully obtained 3D coregistered PA/US ex vivo images using an iliac artery from a rabbit atherosclerosis model. Accordingly, lipid-rich plaques were sufficiently differentiated from normal tissue in the ex vivo experiment. We validated these findings histologically to confirm the lipid content.

  10. Intravascular ultrasound tissue harmonic imaging in vivo.

    Science.gov (United States)

    Frijlink, Martijn E; Goertz, David E; van Damme, Luc C A; Krams, Rob; van der Steen, Antonius F W

    2006-10-01

    Tissue harmonic imaging (THI) has been shown to increase image quality of medical ultrasound in the frequency range from 2 to 10 MHz and might, therefore, also be used to improve image quality in intravascular ultrasound (IVUS). In this study we constructed a prototype IVUS system that could operate in both fundamental frequency and second harmonic imaging modes. This system uses a conventional, continuously rotating, single-element IVUS catheter and was operated in fundamental 20 MHz, fundamental 40 MHz, and harmonic 40 MHz modes (transmit 20 MHz, receive 40 MHz). Hydrophone beam characterization measurements demonstrated the build-up of a second harmonic signal as a function of increasing pressure. Imaging experiments were conducted in both a tissue-mimicking phantom and in an atherosclerotic animal model in vivo. Acquisitions of fundamental 20 and 40 MHz and second harmonic acquisitions resulted in cross sections of the phantom and a rabbit aorta. The harmonic results of the imaging experiments showed the feasibility of intravascular THI with a conventional IVUS catheter both in a phantom and in vivo. The harmonic acquisitions also showed the potential of THI to reduce image artifacts compared to fundamental imaging.

  11. Intravascular Ultrasound Image Segmentation Using Morphological Snakes

    Directory of Open Access Journals (Sweden)

    Hamdi Mohamed Ali

    2012-06-01

    Full Text Available From the first use of the technics of intravascular ultrasound (IVUS as an imaging technique for the coronary artery system at the 70th century until now , the segmentation of the arterial wall boundaries still an important problem . Much research has been done to give better segmentation result for better diagnostics , evaluation and therapy planning. In this paper we present a new segmentation technics based on Morphological Snakes which developed by Luis Álvarez used for the first time for IVUS segmentation. It is a simple , fast and stable approach of snakes evolution algorithm. Results are presented and discussed in order to demonstrate the effectiveness of this approach in IVUS segmentation.

  12. Subharmonic Contrast Intravascular Ultrasound for Vasa Vasorum Imaging

    NARCIS (Netherlands)

    Goertz, David E.; Frijlink, Martijn E.; Tempel, Dennie; Bhagwandas, Vijay; Gisolf, Andries; Krams, Robert; Jong, de Nico; Steen, van der Antonius F.W.

    2007-01-01

    The feasibility of subharmonic contrast intravascular ultrasound (IVUS) imaging was investigated using a prototype nonlinear IVUS system and the commercial contrast agent Definity™. The system employed a mechanically scanned commercial catheter with a custom transducer element fabricated to have sen

  13. Micromachined capacitive transducer arrays for intravascular ultrasound

    Science.gov (United States)

    Degertekin, F. Levent; Guldiken, R. Oytun; Karaman, Mustafa

    2005-01-01

    Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric transducer technology. The limitations in the manufacture and performance of the same piezoelectric transducers have also impeded the improvement of IVUS for emerging clinically important applications such as forward viewing arrays for guiding interventions and high resolution imaging of arterial structure such as vulnerable plaque and fibrous cap, and also implementation of techniques such as harmonic imaging of the tissue and of the contrast agents. Capacitive micromachined ultrasonic transducer (CMUT) technology shows great potential for transforming IVUS not only to satisfy these clinical needs but also to open up possibilities for low-cost imaging devices integrated to therapeutic tools. We have developed manufacturing processes with a maximum process temperature of 250°C to build CMUTs on the same silicon chip with integrated electronics. Using these processes we fabricated CMUT arrays suitable for forward viewing IVUS in the 10-20MHz range. We characterized these array elements in terms of pulse-echo response, radiation pattern measurements and demonstrated its volumetric imaging capabilities on various imaging targets.

  14. Intravascular ultrasound for angiographically indeterminant left main coronary artery disease.

    Science.gov (United States)

    Parashara, D K; Jacobs, L E; Ledley, G S; Yazdanfar, S; Oline, J; Kotler, M N

    1994-01-01

    The precise diagnosis of the presence of significant left main coronary artery disease has profound prognostic and therapeutic implications. Coronary cineangiography has shown to be imprecise and inaccurate to determine the percent stenosis of the left main coronary artery. We report a case with significant left main coronary artery disease in whom coronary cineangiography was in discordance with the clinical data and intravascular ultrasonography. Based on the intravascular ultrasound findings, the patient underwent coronary artery bypass graft surgery. Therefore, the intravascular ultrasonography may be the procedure of choice for assessing indeterminant left main coronary artery lesions by coronary angiography.

  15. Application of tissue characterization in intravascular ultrasound imaging

    Science.gov (United States)

    Mullen, William L.; Fitzgerald, Peter J.; Yock, Paul G.

    1994-05-01

    Current intravascular ultrasound imaging technology is able to determine the extent and distribution of pathologic processes within the vessel wall, but is not highly sensitive in discriminating between certain types of tissue. `Tissue characterization' refers to a set of computer-based techniques that utilize features of the ultrasound signal beyond basic amplitude to help define the composition of the tissue of interest. This technique involves quantitative analysis of the ultrasound signals reflected from tissue before these signals pass through the processing steps in the ultrasound instrument.

  16. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  17. Intravascular ultrasound in the endovascular management of atherosclerotic peripheral occlusive disease.

    Science.gov (United States)

    Colli, Rosa; Di Stasi, Carmine; Modugno, Pietro; Orlando, Giuseppe; Cavallaro, Antonio

    2004-01-01

    This study is a retrospective analysis of the impact of intravascular ultrasound in addiction to conventional angiography in 36 patients with 55 stenotic peripheral arterial lesions treated with angioplasty and/or stenting. Before treatment, intravascular ultrasound imaging showed that the vessel diameter was underestimated with angiography in 6 cases. The correlation index between angiography and intravascular ultrasound measurements, however, was significant in 27 arterial lesions. After endovascular treatment, angiography showed 3 vessel dissections and no incomplete stent deployment, whereas intravascular ultrasound showed 15 dissections and 5 instances of stent underdeployment. If we consider the intravascular ultrasound data as the gold standard, the specificity of angiography is 100%, while its sensitivity is 56% for vessel dissection and 75% for stent deployment. In the follow up of the 16 patients treated for iliac lesions with intravascular ultrasound control, re-stenosis occurred in 5% (primary patency 94.7%); in a control group of 15 patients treated in the same period without intravascular ultrasound control, re-stenosis occurred in 15.8% (primary patency 83.4%, difference not statistically significant). In conclusion, in the peripheral arteries intravascular ultrasound is more accurate than arteriography in evaluating dissection and stent deployment, but the routine use of intravascular ultrasound in every case of iliac PTA or stenting would not appear justified.

  18. Experience With Intravascular Ultrasound Imaging Of Human Atherosclerotic Arteries

    Science.gov (United States)

    Mallery, John A.; Gessert, James M.; Maciel, Mario; Tobis, John M.; Griffith, James M.; Berns, Michael W.; Henry, Walter L.

    1989-08-01

    Normal human arteries have a well-defined structure on intravascular images. The intima appears very thin and is most likely represented by a bright reflection arising from the internal elastic lamina. The smooth muscle tunica media is echo-lucent on the ultrasound image and appears as a dark band separating the intima from the adventitia. The adventitia is a brightly reflective layer of variable thickness. The thickness of the intima, and therefore of the atherosclerotic plaque can be accurately measured from the ultrasound images and correlates well with histology. Calcification within the wall of arteries is seen as bright echo reflection with shadowing of the peripheral wall. Fibrotic regions are highly reflective but do not shadow. Necrotic liquid regions within advanced atherosclerotic plaques are seen on ultrasound images as large lucent zones surrounded by echogenic tissue. Imaging can be performed before and after interventional procedures, such as laser angioplasty, balloon angioplasty and atherectomy. Intravascular ultrasound appears to provide an imaging modality for identifying the histologic characteristics of diseased arteries and for quantifying plaque thickness. It might be possible to perform such quantification to evaluate the results of interventional procedures.

  19. Development of catheters for combined intravascular ultrasound and photoacoustic imaging

    Science.gov (United States)

    Karpiouk, Andrei B.; Wang, Bo; Emelianov, Stanislav Y.

    2009-02-01

    Coronary atherosclerosis is a complex disease accompanied by the development of plaques in the arterial wall. Since the vulnerability of the plaques depends on their composition, the appropriate treatment of the arteriosclerosis requires a reliable characterization of the plaques' geometry and content. The intravascular ultrasound (IVUS) imaging is capable of providing structural details of the plaques as well as some functional information. In turn, more functional information about the same plaques can be obtained from intravascular photoacoustic (IVPA) images since the optical properties of the plaque's components differ from that of their environment. The combined IVUS/IVPA imaging is capable of simultaneously detecting and differentiating the plaques, thus determining their vulnerability. The potential of combined IVUS/IVPA imaging has already been demonstrated in phantoms and ex-vivo experiments. However, for in-vivo or clinical imaging, an integrated IVUS/IVPA catheter is required. In this paper, we introduce two prototypes of integrated IVUS/IVPA catheters for in-vivo imaging based on a commercially available single-element IVUS imaging catheter. The light delivery systems are developed using multimode optical fibers with custom-designed distal tips. Both prototypes were tested and compared using an arterial mimicking phantom. The advantages and limitations of both designs are discussed. Overall, the results of our studies suggest that both designs of integrated IVUS/IVPA catheter have a potential for in-vivo IVPA/IVUS imaging of atherosclerotic plaques.

  20. Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro

    NARCIS (Netherlands)

    C.L. de Korte (Chris); G. Pasterkamp (Gerard); H.A. Woutman; N. Bom (Klaas); A.F.W. van der Steen (Ton)

    2000-01-01

    textabstractBACKGROUND: The composition of plaque is a major determinant of coronary-related clinical syndromes. Intravascular ultrasound (IVUS) elastography has proven to be a technique capable of reflecting the mechanical properties of phantom material and the femoral arterial

  1. Application of Near Infrared Spectroscopy, Intravascular Ultrasound and the Coronary Calcium Score to Predict Adverse Coronary Events

    Science.gov (United States)

    2015-10-01

    Award Number: W81XWH-11-1-0831 TITLE: Application of Near Infrared Spectroscopy, Intravascular Ultrasound and the Coronary Calcium Score to...3. DATES COVERED 26-SEP-2014 to 25-SEP-2015 4. TITLE AND SUBTITLE Application of Near Infrared Spectroscopy, Intravascular Ultrasound and the...planned. 15. SUBJECT TERMS coronary artery disease, near infrared spectroscopy, calcium scoring, intravascular ultrasound 16. SECURIY CLASSIFICATION OF

  2. Subharmonic contrast intravascular ultrasound for vasa vasorum imaging.

    Science.gov (United States)

    Goertz, David E; Frijlink, Martijn E; Tempel, Dennie; Bhagwandas, Vijay; Gisolf, Andries; Krams, Robert; de Jong, Nico; van der Steen, Antonius F W

    2007-12-01

    The feasibility of subharmonic contrast intravascular ultrasound (IVUS) imaging was investigated using a prototype nonlinear IVUS system and the commercial contrast agent Definity . The system employed a mechanically scanned commercial catheter with a custom transducer element fabricated to have sensitivity at both 15 and 30 MHz. Experiments were conducted at a fundamental frequency of 30 MHz (F30; 25% bandwidth), with on-axis pressures ranging from 0.12 to 0.79 MPa, as measured with a needle hydrophone. In vitro characterization experiments demonstrated the detection of 15 MHz subharmonic signals (SH15) when pressure levels reached 360 kPa. The formation of SH15 images was shown, with tissue signals suppressed to near the noise floor and contrast to tissue ratios were improved by up to 30 dB relative to F30. In vivo experiments were performed using the atherosclerotic rabbit aorta model. Following the bolus injection of contrast agent upstream of the imaging catheter, agent was detected within the aorta, vena cava and within the perivascular space. These results provide a first in vivo demonstration of subharmonic contrast IVUS and suggest its potential as a new technique for imaging vasa vasorum.

  3. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels;

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  4. Assessment of culprit lesions by intravascular ultrasound in patients with acute myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    LIU Jian; LIU Chuan-fen; LU Ming-yu; MA Yu-liang; WANG Long; CHEN Hong; WANG Wei-min

    2009-01-01

    Background Intravascular ultrasound has become the standard invasive method for diagnosing coronary artery disease. The aim of the present study was to evaluate the ability of intravascular ultrasound for assessment of culprit lesion morphology during primary percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI).Methods We performed 18 intravascular ultrasound assessments preintervention during the primary PCI for AMI. intravascular ultrasound analysis included qualitative and quantitative measurements of reference and lesion extemal elastic membrane (EEM), lumen, and plaque plus media (P&M) area. Positive remodeling was defined as lesion/mean reference EEM >1.0. Culprit lesions were identified by a combination of electrocardiogram (ECG) and coronary angiography.Results There was an average of 1.44 infarct-related artery (IRA) plaques per patient. The incidences of thrombus and plaque ruptures were 28% (5) and 33% (6), respectively. Hypoechoic plaque was observed in 72% (13) of AMI patients. Calcified lesions could be found in 33% (6) of culprit lesions. Sixty percent of the culprit lesion sites presented with positive remodeling.Conclusions Intravascular ultrasound is a safe and feasible imaging modality in patients with AMI and can help identify plaque rupture, intracoronary thrombus or calcification. The culprit lesion site in AMI cases often presents with positive remodeling.

  5. Development of a Mechanical Scanning-type Intravascular Ultrasound System Using a Miniature Ultrasound Motor

    Science.gov (United States)

    Tanabe, Masayuki; Xie, Shangping; Tagawa, Norio; Moriya, Tadashi; Furukawa, Yuji

    2007-07-01

    Intravascular ultrasound (IVUS) plays an important role for the detection of arteriosclerosis, which causes the ischemic heart disease. In mechanical scanning-type IVUS, it is necessary to rotate a transducer or a reflecting mirror. A method that involves rotating the transducer using a torque wire causes image distortion (NURD: non uniform rotation distortion). For a method that involves placing an electromagnetic motor on the tip of an IVUS probe is difficult to miniaturize the probe. Our objectives are to miniaturize the probe (1 mm in diameter, 5 mm in length) and to remove NURD. Therefore, we conducted a study to assess the feasibility of attaining these objectives by constructing a prototype IVUS system, in which an ultrasound motor using a stator in the form of a helical coil (abbreviated as CS-USM: coiled stator-ultrasonic motor) is incorporated, and to clarify problems that need to be solved in constructing the probe.

  6. Oblong-Shaped-Focused Transducers for Intravascular Ultrasound Imaging.

    Science.gov (United States)

    Lee, Junsu; Jang, Jihun; Chang, Jin Ho

    2017-03-01

    In intravascular ultrasound (IVUS) imaging, a transducer is inserted into a blood vessel and rotated to obtain image data. For this purpose, the transducer aperture is typically less than 0.5 mm in diameter, which causes natural focusing to occur in the imaging depth ranging from 1 to 5 mm. Due to the small aperture, however, it is not viable to conduct geometric focusing in order to enhance the spatial resolution of IVUS images. Furthermore, this hampers narrowing the slice thickness of a cross-sectional scan plane in the imaging depth, which leads to lowering spatial and contrast resolutions of IVUS images. To solve this problem, we propose an oblong-shaped-focused transducer for IVUS imaging. Unlike the conventional IVUS transducers with either a circular or a square flat aperture, the proposed transducer has an oblong aperture of which long side is positioned along a blood vessel. This unique configuration makes it possible to conduct geometric focusing at a desired depth in the elevation direction. In this study, furthermore, it is demonstrated that a spherically shaped aperture in both lateral and elevation directions also improves lateral resolution, compared to the conventional flat aperture. To ascertain this, the conventional and the proposed IVUS transducers were designed and fabricated to evaluate and to compare their imaging performances through wire phantom and tissue-mimicking phantom experiments. For the proposed 50-MHz IVUS transducer, a PZT piece of 0.5 × 1.0 mm(2) was spherically shaped for elevation focus at 3 mm by using the conventional press-focusing technique whereas the conventional one has a flat aperture of 0.5 × 0.5 mm(2). The experimental results demonstrated that the proposed IVUS transducer is capable of improving spatial and contrast resolutions of IVUS images.

  7. Intravascular ultrasound predictors of CD163 positive macrophage infiltration.

    Science.gov (United States)

    Sato, Takao; Kameyama, Tomoki; Ueno, Hiroshi; Inoue, Hiroshi

    2014-06-01

    The present study aimed to determine characteristics of macrophage accumulation and predictors of CD163 positive macrophages by ultrasonic tissue characterization. Intraplaque hemorrhage is associated with plaque instability and induces macrophage accumulation with a scavenger receptor, CD163. These CD163 positive macrophages have anti-atherogenic property. In 50 patients with acute coronary syndrome, lumen, vessel and plaque area, and plaque components (% fibrous, % fibro fatty, % dense calcium, and % necrotic core) of the culprit lesion were determined by virtual histology (VH) intravascular ultrasound (IVUS). Remodeling index (RI) was also determined. Atherothrombotic debris of the culprit lesion was collected during percutaneous coronary intervention using a distal protection device. CD163 positive macrophages and glycophorin A (a protein specific to erythrocytes) were determined immunohistochemically. Percentage of CD163 positive macrophages to the whole cells (% CD163) correlated positively with lumen, vessel and plaque area, and RI. Further, % CD163 had significant positive correlation with % necrotic core and negative correlation with % dense calcium. Immunopositive areas of glycophorin A (% glycophorin A), expressed as the ratio of positively stained areas per total tissue, had a significant positive correlation with % CD163. On multivariate analysis, % necrotic core, % dense calcium, and RI were independent determinants of % CD163. Positive remodeling and large necrotic core without calcification on VH-IVUS were likely to indicate coronary intraplaque hemorrhage with CD163 positive macrophages infiltration. © 2014, Wiley Periodicals, Inc.

  8. Intravascular ultrasound-guided stenting of left main stem dissection after Medtronic Corevalve implantation.

    Science.gov (United States)

    Van Mieghem, N M; de Jaegere, P P

    2013-08-01

    Transcatheter aortic valve implantation (TAVI) implies the introduction, positioning, and deployment of a stented bioprosthesis in the (calcified) native aortic valve. We report an at first glance uneventful TAVI with the Medtronic Corevalve System, which was followed by transient electrocardiographic changes suggesting acute left main stem disease. The diagnosis of acute left main stem dissection extending from the left coronary cusp was firmly established by intravascular ultrasound. The ostium of the left main stem was successfully treated with intravascular ultrasound-guided placement of a drug eluting stent. © 2013 Wiley Periodicals, Inc.

  9. Intravascular Ultrasound in Percutaneous Coronary Intervention for Chronic Total Occlusion

    Directory of Open Access Journals (Sweden)

    M Mohandes

    2010-09-01

    Full Text Available Background: Percutaneous coronary intervention (PCI of chronic total occlusion (CTO is one of the most challenging procedures in interventional cardiology. New techniques and devices have made possible to face these complex procedures. Intravascular ultrasound (IVUS reveals special features and contributes greatly to procedural success.Method: We analysed retrospectively IVUS contribution and findings in 23 cases of a total 46 CTOs PCI from February 2009 to August 2010 in our cath lab. Both true and functional CTO were included in this study. The procedure was considered successful when a TIMI III flow was reached in the occluded vessel after stent implantation with a residual stenosis less than 30%. IVUS features and contribution in CTO-PCI were analysed. All data were introduced in SPSS version 15 (SPSS Inc. Chicago, Illinois, USA. Continuous variables were described by mean ± SD and categorical variables were expressed as percentage. A P<0.05 was considered statistically significant.Results: 46 PCIs in 34 patients were performed during 19 months in our centre. The procedure was successful in 28 cases (60.9%.. IVUS was performed in 23 (82.1% of successful procedures. IVUS revealed calcium somewhere in 17 (73.9%. Despite wire angiographic verification in true lumen distally IVUS showed subintimal wire position in part of CTO segment in 6(26.1%. In 22(95.7% of cases IVUS allowed both the wire position verification in true lumen and the vessel measurement before stent implantation. In 1(4.3% case a second wire was introduced into true lumen guided by IVUS after realising that the first wire was in false lumen. We could not find significant relation between calcium presence and subintimal wire penetration in CTO segment (p: 0.14 Conclusions: IVUS showed calcium in CTO segment in a high percentage of cases. It is not unusual to find wire penetration in subintimal space in part of CTO segment. IVUS has a key contribution in the step by step

  10. All-optical pulse-echo ultrasound probe for intravascular imaging (Conference Presentation)

    Science.gov (United States)

    Colchester, Richard J.; Noimark, Sacha; Mosse, Charles A.; Zhang, Edward Z.; Beard, Paul C.; Parkin, Ivan P.; Papakonstantinou, Ioannis; Desjardins, Adrien E.

    2016-02-01

    High frequency ultrasound probes such as intravascular ultrasound (IVUS) and intracardiac echocardiography (ICE) catheters can be invaluable for guiding minimally invasive medical procedures in cardiology such as coronary stent placement and ablation. With current-generation ultrasound probes, ultrasound is generated and received electrically. The complexities involved with fabricating these electrical probes can result in high costs that limit their clinical applicability. Additionally, it can be challenging to achieve wide transmission bandwidths and adequate wideband reception sensitivity with small piezoelectric elements. Optical methods for transmitting and receiving ultrasound are emerging as alternatives to their electrical counterparts. They offer several distinguishing advantages, including the potential to generate and detect the broadband ultrasound fields (tens of MHz) required for high resolution imaging. In this study, we developed a miniature, side-looking, pulse-echo ultrasound probe for intravascular imaging, with fibre-optic transmission and reception. The axial resolution was better than 70 microns, and the imaging depth in tissue was greater than 1 cm. Ultrasound transmission was performed by photoacoustic excitation of a carbon nanotube/polydimethylsiloxane composite material; ultrasound reception, with a fibre-optic Fabry-Perot cavity. Ex vivo tissue studies, which included healthy swine tissue and diseased human tissue, demonstrated the strong potential of this technique. To our knowledge, this is the first study to achieve an all-optical pulse-echo ultrasound probe for intravascular imaging. The potential for performing all-optical B-mode imaging (2D and 3D) with virtual arrays of transmit/receive elements, and hybrid imaging with pulse-echo ultrasound and photoacoustic sensing are discussed.

  11. Orbital Atherectomy Plaque Modification Assessment of the Femoropopliteal Artery Via Intravascular Ultrasound (TRUTH Study)

    OpenAIRE

    Babaev, Anvar; Zavlunova, Susanna; Attubato, Michael J.; Martinsen, Brad J.; Mintz,Gary S.; Maehara, Akiko

    2015-01-01

    Objective: The Tissue Removal Assessment with Ultrasound of the SFA and Popliteal (TRUTH) study assessed the performance of the orbital atherectomy system (OAS) to treat femoropopliteal arteries, including determining its effect on plaque removal. Methods: Patients with symptomatic femoropopliteal peripheral arterial disease were treated with the OAS followed by adjunctive balloon angioplasty (BA). Intravascular ultrasound (IVUS) images were collected pre- and post-OAS and post-OAS BA. Patien...

  12. Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo: a Yucatan pig study.

    NARCIS (Netherlands)

    Korte, C.L. de; Sierevogel, M.J.; Mastik, F.; Strijder, C.; Schaar, J.A.; Velema, E.; Pasterkamp, G.; Serruys, P.W.; Steen, A.F.W. van der

    2002-01-01

    BACKGROUND: Intravascular ultrasound elastography assesses the local strain of the atherosclerotic vessel wall. In the present study, the potential to identify different plaque components in vivo was investigated. METHODS AND RESULTS: Atherosclerotic external iliac and femoral arteries (n=24) of 6 Y

  13. Serial intravascular ultrasound assessment of changes in coronary atherosclerotic plaque dimensions and composition: an update

    DEFF Research Database (Denmark)

    Hartmann, Marc; Huisman, Jennifer; Böse, Dirk;

    2011-01-01

    This manuscript reviews the use of serial intravascular ultrasound (IVUS) examination of coronary atherosclerosis in recent observational studies and randomized trials that revealed the effects of cholesterol-lowering and lipid-modifying therapies and offered novel insight into plaque progression...

  14. Three-dimensional quantitative coronary angiography and the registration with intravascular ultrasound and optical coherence tomography

    NARCIS (Netherlands)

    Tu, Shengxian

    2012-01-01

    This thesis proposes several new algorithms including X-ray angiographic image enhancement, three-dimensional (3D) angiographic reconstruction, angiographic overlap prediction, and the co-registration of X-ray angiography with intracoronary imaging devices, such as intravascular ultrasound (IVUS) an

  15. Coronary plaque composition as assessed by greyscale intravascular ultrasound and radiofrequency spectral data analysis

    NARCIS (Netherlands)

    N. Gonzalo (Nieves); H.M. Garcia-Garcia (Hector); J.M.R. Ligthart (Jürgen); G.A. Rodriguez-Granillo (Gaston); E. Meliga (Emanuele); Y. Onuma (Yoshinobu); J.C.H. Schuurbiers (Johan); N. Bruining (Nico); P.W.J.C. Serruys (Patrick)

    2008-01-01

    textabstractObjectives: (i) To explore the relation between greyscale intravascular ultrasound (IVUS) plaque qualitative classification and IVUS radiofrequency data (RFD) analysis tissue types; (ii) to evaluate if plaque composition as assessed by RFD analysis can be predicted by visual assessment o

  16. Recanalized chronic coronary thrombus: unraveling a hazy coronary lesion by intravascular ultrasound.

    Science.gov (United States)

    Karamasis, Grigoris V; Chotai, Shayna; Khokhar, Azhar A; Kelly, Paul A

    2016-04-01

    Hazy lesions in coronary angiography can often be a puzzle for the interventional cardiologist. Recanalized chronic coronary thrombus, although rare, is one of the potential diagnoses. Intracoronary imaging with intravascular ultrasound (IVUS) and optical coherence tomography (OCT) are tools that can guide to the correct diagnosis. We present the images of a case where IVUS was used to unravel such a lesion.

  17. Transbiliary intravascular ultrasound-guided diagnostic biopsy of an inaccessible pancreatic head mass

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2017-06-01

    Full Text Available Percutaneous image-guided biopsies of pancreatic malignancies may prove challenging and nondiagnostic due to a variety of anatomic considerations. For patients with complex post-surgical anatomy, such as a Roux-en-Y gastric bypass, diagnosis via endoscopic ultrasound with fine-needle aspiration may not be possible because of an inability to reach the proximal duodenum. This report describes the first diagnostic case of transbiliary intravascular ultrasound-guided biopsy of a pancreatic head mass in a patient with prior Roux-en-Y gastric bypass for which a diagnosis could not be achieved via percutaneous and endoscopic approaches. Transbiliary intravascular ultrasound-guided biopsy resulted in a diagnosis of pancreatic adenocarcinoma, allowing the initiation of chemotherapy.

  18. Design of low noise transimpedance amplifier for intravascular ultrasound

    KAUST Repository

    Reda, Dina

    2009-11-01

    In this paper, we study transimpedance amplifiers for capacitive sensing applications with a focus on Intravascular Ultra Sound (IVUS). We employ RF noise cancellation technique on capacitive feedback based transimpedance amplifiers. This technique eliminates the input-referred noise of TIAs completely and enhances the dynamic range of front-end electronics. Simulation results verify the proposed technique used in two different TIA topologies employing shunt-shunt feedback. ©2009 IEEE.

  19. The effect of vascular curvature on three-dimensional reconstruction of intravascular ultrasound images.

    Science.gov (United States)

    Wiet, S P; Vonesh, M J; Waligora, M J; Kane, B J; McPherson, D D

    1996-01-01

    To characterize the effect of vessel curvature on the geometric accuracy of conventional three-dimensional reconstruction (3DR) algorithms for intravascular ultrasound image data. A common method of 3DR for intravascular ultrasound image data involves geometric reassembly and volumetric interpolation of a spatially related sequence of tomographic cross sections generated by an ultrasound catheter withdrawn at a constant rate through a vascular segment of interest. The resulting 3DR is displayed as a straight segment, with inherent vascular curvature neglected. Most vascular structures, however, are not straight but curved to some degree. For this reason, vascular curvature may influence the accuracy of computer-generated 3DR. We collected image data using three different intravascular ultrasound catheters (2.9 Fr, 4.3 Fr, 8.0 Fr) during a constant-rate pullback of 1 mm/sec through tubing of known diameter with imposed radii of curvature ranging from 2 to 10 cm. Image data were also collected from straight tubing. Image data were digitized at 1.0-mm intervals through a length of 25 mm. Two passes through each radius of curvature were performed with each intravascular ultrasound catheter. 3DR lumen volume for each radius of curvature was compared to that theoretically expected from a straight cylindrical segment. Differences between 3DR lumen volume of theoretical versus curved (actual) tubes were quantified as absolute percentage error and categorized as a function of curvature. Tubing deformation error was quantified by quantitative coronary angiography (QCA). Volumetric errors ranged from 1% to 35%, with an inverse relationship demonstrated between 3DR lumen volume and segmental radius of curvature. Higher curvatures (r curvatures (r > 6.0 cm). This trend was exhibited for all three catheters and was shown to be independent of tubing deformation artifacts. QCA-determined percentage diameter stenosis indicated no deformation error as a function of curvature. Total

  20. Regression of coronary atherosclerosis by simvastatin: a serial intravascular ultrasound study

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Pedersen, Knud Erik;

    2004-01-01

    BACKGROUND: Angiography of the coronary arteries reflects only changes in luminal dimensions. With intravascular ultrasound, cross-sectional images can be obtained and area measurements can be added to calculate volumes of the external elastic membrane (EEM), plaque plus media (P+M), and lumen...... in a not previously revascularized coronary artery, serial intravascular ultrasound studies with an ECG-triggered pullback were performed at baseline, after 3 months on a lipid-lowering diet, and after another 12 months on simvastatin 40 mg/d. Mean length of the analyzed atherosclerotic segments was 5.9+/-3.3 mm.......2+/-0.7 mmol/L, Ptherapy with simvastatin for 12 months is associated with a significant P+M regression in coronary arteries measured as reduction in P+M and EEM volumes without any...

  1. Study of restenosis in drug eluting stents: new insights from greyscale intravascular ultrasound and virtual histology.

    Science.gov (United States)

    Garcia-Garcia, Hector M; Shen, Zhujun; Piazza, Nicolo

    2009-05-01

    In current cardiology practice, many patients undergo secondary revascularisation due to reduced long-term vein graft patency or in-stent restenosis. In this report, we describe causes of drug-eluting stent restenosis identifiable by intravascular ultrasound imaging (IVUS) and variables related to restenosis used for reporting greyscale IVUS. In addition, IVUS findings in bypass grafts and the long-term results after stent implantation are provided. Finally, the usefulness of IVUS virtual histology for the study of restenosis is described.

  2. Fixed Coronary Artery Stenosis in Tunneled Coronary Artery Identified by Intravascular Ultrasound: A Case Report

    Directory of Open Access Journals (Sweden)

    Yuxiang Dai

    2014-10-01

    Full Text Available Myocardial bridging is characterized as the compression of a segment of the coronary artery during systole. Significant atherosclerosis within the bridge is almost never seen at pathologic examination because of the absence of synthetic type smooth muscle cells in the intima of the tunneled artery. To date, there have been no reports of significant atherosclerosis at the site of myocardial bridging documented by angiography or intravenous ultrasound. We report a rare case of fixed coronary artery stenosis at the site of myocardial bridging identified by intravascular ultrasound.

  3. Potential for tissue characterization of plaque and arterial wall using intravascular ultrasound

    Science.gov (United States)

    Sudhir, Krishnakutty; Fitzgerald, Peter J.; Yock, Paul G.

    1993-09-01

    Current intravascular ultrasound imaging technology is able to determine the extent and distribution of pathologic processes within the vessel wall, but is not highly sensitive in discriminating between different types of pathologic tissue. `Tissue characterization' refers to a set of computer-based techniques that utilize features of the ultrasound signal beyond basic amplitude to help define the structure of the tissue of interest. Although preliminary results with this approach are encouraging, additional work is needed to define its clinical application in vascular disease.

  4. Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications.

    Science.gov (United States)

    Zahorian, Jaime; Hochman, Michael; Xu, Toby; Satir, Sarp; Gurun, Gokce; Karaman, Mustafa; Degertekin, F Levent

    2011-12-01

    One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter-based volumetric imaging arrays, for which the elements must be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom-designed CMOS receiver electronics from a commercial IC foundry. The CMUT-on-CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low-temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT-to-CMOS interconnection. This CMUT-to-CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire-bonding method. Characterization experiments indicate that the CMUT-on-CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Ex- periments on a 1.6-mm-diameter dual-ring CMUT array with a center frequency of 15 MHz show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging chronic total occlusions located 1 cm from the CMUT array.

  5. Relationship between coronary angioscopic and intravascular ultrasound imaging and restenosis.

    Science.gov (United States)

    Xu, S; Nomura, M; Kurokawa, H; Ando, T; Kimura, M; Ishii, J; Hasegawa, H; Kondo, T; Tadiki, S; Qi, P

    1995-10-01

    In order to investigate the relationship between restenosis and the morphology detected by coronary angioscopy (CASC) and introvascular ultrasound imaging (IVUS), 17 patients were detected by CASC and IVUS immediately and 3 months after percutaneous transluminal coronary angioscopy (PTCA). The results showed that the dilation index by IVUS (DIu) was significantly lower in restenosis patients than in non-restenosis patients (0.42 +/- 0.08 versus 0.78 +/- 0.16, P < 0.01) and that the elastic recoil (ER) was higher in restenosis patients than in non-restenosis patients (4.51 +/- 1.42 mm2 versus 1.63 +/- 1.20 mm2, P < 0.01), and that the elastic recoil rate (ERR) was also higher in restenosis patients than in non-restenosis patients (57.3 +/- 8.07% versus 21.80 +/- 16.84% P < 0.01), and that coronary dissection, atheromatous plaque and calcification as well as the colour of inner coronary artery had no relation with chronic restenosis. In conclusion, the elastic recoil is one of the important factors of chronic restenosis after PTCA.

  6. Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per

    2007-01-01

    Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected...... in changes between 2 electrocardiographically gated and 2 nongated pullbacks (lumen: 0.37 +/- 1.76 vs -0.23 +/- 2.32 mm(3), p = NS; EEM: 0.25 +/- 3.22 vs -0.94 +/- 4.27 mm(3), p = NS; P+M: -0.18 +/- 3.42 vs -0.74 +/- 3.88 mm(3), p = NS). In conclusion, in moderate atherosclerotic or stented coronary arteries...

  7. Automated Contour Detection for Intravascular Ultrasound Image Sequences Based on Fast Active Contour Algorithm

    Institute of Scientific and Technical Information of China (English)

    DONG Hai-yan; WANG Hui-nan

    2006-01-01

    Intravascular ultrasound can provide high-resolution real-time crosssectional images about lumen, plaque and tissue. Traditionally, the luminal border and medial-adventitial border are traced manually. This process is extremely timeconsuming and the subjective difference would be large. In this paper, a new automated contour detection method is introduced based on fast active contour model.Experimental results found that lumen and vessel area measurements after automated detection showed good agreement with manual tracings with high correlation coefficients (0.94 and 0.95, respectively) and small system difference ( -0.32 and 0.56, respectively). So it can be a reliable and accurate diagnostic tool.

  8. Micromachined PIN-PMN-PT Crystal Composite Transducer for High-Frequency Intravascular Ultrasound (IVUS) Imaging

    OpenAIRE

    Li, Xiang; Ma, Teng; Tian, Jian; Han, Pengdi; Zhou, Qifa; Shung, K. Kirk

    2014-01-01

    In this paper, we report the use of micromachined PbIn1/2Nb1/2O3–PbMg1/3Nb2/3O3–PbTiO3 (PIN-PMN-PT) single crystal 1–3 composite material for intravascular ultrasound (IVUS) imaging application. The effective electromechanical coupling coefficient kt(eff) of the composite was measured to be 0.75 to 0.78. Acoustic impedance was estimated to be 20 MRayl. Based on the composite, needle-type and flexible-type IVUS transducers were fabricated. The composite transducer achieved an 86% bandwidth at ...

  9. Offline fusion of co-registered intravascular ultrasound and frequency domain optical coherence tomography images for the analysis of human atherosclerotic plaques

    DEFF Research Database (Denmark)

    Räber, Lorenz; Heo, Jung Ho; Radu, Maria D

    2012-01-01

    To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.......To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images....

  10. Lead-Free Intravascular Ultrasound Transducer Using BZT-50BCT Ceramics

    Science.gov (United States)

    Yan, Xingwei; Lam, Kwok Ho; Li, Xiang; Chen, Ruimin; Ren, Wei; Ren, Xiaobing; Zhou, Qifa; Shung, K. Kirk

    2013-01-01

    This paper reports the fabrication and evaluation of a high-frequency ultrasonic transducer based on a new lead-free piezoelectric material for intravascular imaging application. Lead-free 0.5Ba(Zr0.2Ti0.8)O3−0.5(Ba0.7Ca0.3)TiO3 (BZT-50BCT) ceramic with a high dielectric constant (~2800) was employed to develop a high-frequency (~30 MHz) needle-type ultrasonic transducer. With superior piezoelectric performance (piezoelectric coefficient d33 ~ 600 pC/N), the lead-free transducer was found to exhibit a −6-dB bandwidth of 53% with an insertion loss of 18.7 dB. In vitro intravascular ultrasound (IVUS) imaging of a human cadaver coronary artery was performed to demonstrate the potential of the lead-free transducer for biomedical imaging applications. This is the first time that a lead-free transducer has been used for IVUS imaging application. The experimental results suggest that the BZT-50BCT ceramic is a promising lead-free piezoelectric material for high-frequency intravascular imaging applications. PMID:25004492

  11. Intravascular ultrasound radiofrequency analysis after optimal coronary stenting with initial quantitative coronary angiography guidance: An ATHEROREMO sub-study

    NARCIS (Netherlands)

    G. Sarno (Giovanna); S.A. Garg (Scot); J. Gomez-Lara (Josep); H.M. Garcia-Garcia (Hector); J.M.R. Ligthart (Jürgen); N. Bruining (Nico); Y. Onuma (Yoshinobu); K. Witberg (Karen); R.J.M. van Geuns (Robert Jan); S.P.M. de Boer (Sanneke); J.J. Wykrzykowska (Joanna); C.J. Schultz (Carl); H.J. Duckers (Henricus); E.S. Regar (Eveline); P.P.T. de Jaegere (Peter); P.J. de Feyter (Pim); G.A. van Es (Gerrit Anne); H. Boersma (Eric); W.J. van der Giessen (Wim); P.W.J.C. Serruys (Patrick)

    2011-01-01

    textabstractAims: To investigate whether the use of intravascular ultrasound virtual histology (IVUS-VH) leads to any improvements in stent deployment, when performed in patients considered to have had an optimal percutaneous coronary intervention (PCI) by quantitative coronary angiography (QCA). Me

  12. Successful percutaneous transluminal angioplasty and stenting for symptomatic intracranial vertebral artery stenosis using intravascular ultrasound virtual histology.

    Science.gov (United States)

    Takayama, Katsutoshi; Taoka, Toshiaki; Nakagawa, Hiroyuki; Myouchin, Kaoru; Wada, Takeshi; Sakamoto, Masahiko; Fukusumi, Akio; Iwasaki, Satoru; Kurokawa, Shinichiro; Kichikawa, Kimihiko

    2007-06-01

    This is the first report of percutaneous transluminal angioplasty (PTA) of an intracranial artery applying intravascular ultrasound virtual histology (IVUS-VH), which has been recently developed for tissue characterization of coronary artery plaque. We report a case of successful PTA and stenting for symptomatic intracranial vertebral artery stenosis using IVUS-VH.

  13. The expanding indications for virtual histology intravascular ultrasound for plaque analysis prior to carotid stenting.

    Science.gov (United States)

    Schiro, B J; Wholey, M H

    2008-12-01

    Complications of carotid artery stenting (CAS), including stroke, remain relatively high when compared with carotid endarterectomy (CEA). Current selection criteria for patients undergoing CAS are based predominately on surgical risk related to other comorbidities. Little attention is given to the morphology of the atherosclerotic plaque, although studies have shown that extensive variability exists which confers certain risks for plaque vulnerability. Virtual Histology intravascular ultrasound (VH IVUS) offers a unique method of assessing plaque morphology prior to CAS. Herein, the authors review the concepts of atherosclerotic plaque morphology and discuss the background of VH IVUS and illustrate its use in the carotid system. With selection of the appropriate patient and the appropriate plaque, more favorable outcomes of CAS may be achieved which will solidify its place as a frontline treatment of carotid vascular disease.

  14. A state-of-the-art review on segmentation algorithms in intravascular ultrasound (IVUS) images.

    Science.gov (United States)

    Katouzian, Amin; Angelini, Elsa D; Carlier, Stéphane G; Suri, Jasjit S; Navab, Nassir; Laine, Andrew F

    2012-09-01

    Over the past two decades, intravascular ultrasound (IVUS) image segmentation has remained a challenge for researchers while the use of this imaging modality is rapidly growing in catheterization procedures and in research studies. IVUS provides cross-sectional grayscale images of the arterial wall and the extent of atherosclerotic plaques with high spatial resolution in real time. In this paper, we review recently developed image processing methods for the detection of media-adventitia and luminal borders in IVUS images acquired with different transducers operating at frequencies ranging from 20 to 45 MHz. We discuss methodological challenges, lack of diversity in reported datasets, and weaknesses of quantification metrics that make IVUS segmentation still an open problem despite all efforts. In conclusion, we call for a common reference database, validation metrics, and ground-truth definition with which new and existing algorithms could be benchmarked.

  15. Intravascular ultrasound assessment of remodelling and reference segment plaque burden in type-2 diabetic patients

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S;

    2007-01-01

    with type-2 diabetes mellitus. METHODS AND RESULTS: We used pre-intervention IVUS to study 62 de novo lesions in 43 patients with type-2 diabetes mellitus. The lesion site was the image slice with the smallest lumen cross-sectional area (CSA). The proximal and distal reference segments were the most normal...... size [slope = -0.12 (95% CI -0.17 to -0.07); P type-2 diabetes mellitus. CONCLUSION: Lesions in type-2 diabetic patients are different from previous reports in non-diabetics. Lesions in type-2 diabetics are characterized by a large reference segment plaque burden......AIMS: Intravascular ultrasound (IVUS) assesses arterial remodelling by comparing the lesion external elastic membrane (EEM) with the reference segments; however, reference segments are rarely disease-free. The aim was to assess lesion and reference segment remodelling and plaque burden in patients...

  16. Intravascular ultrasound assessment of very late bare-metal stent thrombosis: a case report

    Institute of Scientific and Technical Information of China (English)

    Ji Hyun Lee; Kyung Min Kim; Jun Won Lee; Sung Gyun Ahn; Young Jin Youn

    2012-01-01

    Very late stent thrombosis (VLST) is increasingly being regarded as a complication of drug-eluting stents (DES),and delayed endothelization,local hypersensitivity reactions,and late stent malapposition due to excessive positive remodeling have been postulated as mechanisms.Considering that stent endothelialization seems to be completed within 4 weeks following bare-metal stent (BMS) placement and that BMS do not possess antiproliferative coating,the mechanism of VLST may differ between patients with DES and those with BMS.We report a case of VLST 9 years after BMS implantation,in which thrombus from the ruptured neointima was confirmed by intravascular ultrasound.This finding suggests that de novo plaque rupture at the neointimal layer within the stent may be one of the explanations for VLST.

  17. (100)-Textured KNN-based thick film with enhanced piezoelectric property for intravascular ultrasound imaging

    Science.gov (United States)

    Zhu, Benpeng; Zhang, Zhiqiang; Ma, Teng; Yang, Xiaofei; Li, Yongxiang; Shung, K. Kirk; Zhou, Qifa

    2015-04-01

    Using tape-casting technology, 35 μm free-standing (100)-textured Li doped KNN (KNLN) thick film was prepared by employing NaNbO3 (NN) as template. It exhibited similar piezoelectric behavior to lead containing materials: a longitudinal piezoelectric coefficient (d33) of ˜150 pm/V and an electromechanical coupling coefficient (kt) of 0.44. Based on this thick film, a 52 MHz side-looking miniature transducer with a bandwidth of 61.5% at -6 dB was built for Intravascular ultrasound (IVUS) imaging. In comparison with 40 MHz PMN-PT single crystal transducer, the rabbit aorta image had better resolution and higher noise-to-signal ratio, indicating that lead-free (100)-textured KNLN thick film may be suitable for IVUS (>50 MHz) imaging.

  18. Infrainguinal CTO Recanalization Assessed by Intravascular Ultrasound: Results of the CENTRAL Study.

    Science.gov (United States)

    Torey, James; Zaitoun, Anwar; Lalonde, Thomas; Runyon, John; Mustapha, Jihad; Davis, Thomas

    2016-11-01

    CENTRAL was a prospective, multicenter, 100 patient study designed to evaluate the ability of a recanalization catheter system to cross chronic total occlusions (CTOs) of the superficial femoral artery while staying within the central vessel lumen. The primary endpoint was the successful crossing of a CTO (≥90% of the length) with the recanalization catheter in the central lumen of the superficial femoral artery in at least one-half of the studied patient population, confirmed by intravascular ultrasound. Secondary endpoints included standardized anatomic damage assessment (the TAPE method) and an assessment of the relationship between the percent of CTO crossing and TAPE scores to the rate of target-lesion revascularization (TLR) at 30 days and 6 months. The mean age of the occlusions was 16.6 ± 22.28 months (range, 1-120 months), the average occlusion length reported by the sites was 132.1 ± 87.69 mm (range, 4-300 mm), and a majority of lesions were moderately (42.0%) or severely (32.0%) calcified. In 43/85 (50.6%) of the evaluable intravascular ultrasound images, the recanalization catheter successfully navigated the central lumen of the CTO (ie, ≥90% luminal crossing) with >50% luminal crossing in 64/85 (75.3%) of cases. The 6-month TLR rate was significantly lower in patients where the CTO was crossed ≥90% in the central vessel lumen (4.7%) compared with crossings CTO crossings achieved intraluminal crossings in >50% of cases and decreased anatomic damage, which appeared to offer a significant advantage in 6-month TLR rates.

  19. Combined optical coherence tomography and intravascular ultrasound radio frequency data analysis for plaque characterization. Classification accuracy of human coronary plaques in vitro

    NARCIS (Netherlands)

    T.P.M. Goderie; G. van Soest (Gijs); H.M. Garcia-Garcia (Hector); N. Gonzalo (Nieves); S. Koljenovic (Senada); G.J.H.L. Leenders (Geert); F. Mastik (Frits); E.S. Regar (Eveline); J.W. Oosterhuis (Wolter); P.W.J.C. Serruys (Patrick); A.F.W. van der Steen (Ton)

    2010-01-01

    textabstractThis study was performed to characterize coronary plaque types by optical coherence tomography (OCT) and intravascular ultrasound (IVUS) radiofrequency (RF) data analysis, and to investigate the possibility of error reduction by combining these techniques. Intracoronary imaging methods h

  20. Intravascular ultrasound-guided angioplasty of hemodialysis loop graft in a patient with contrast allergy.

    Science.gov (United States)

    Casey, Patrick E; Miranda, Charles J; Al-Khaffaf, Haytham; Woodhead, Peter M

    2014-01-01

    A surveillance duplex scan detected a stenosis within a left groin hemodialysis loop graft in a 57-year-old woman who was allergic to both iohexol and gadolinium contrast agents. This precluded the use of standard angioplasty treatment techniques. Intravascular ultrasound (IVUS) uses a catheter mounted with a miniaturized ultrasound probe to produce detailed cross-sectional vessel images. Clinically, it has been used in the assessment of coronary artery disease but has also supplemented standard angiography techniques in the assessment of peripheral vascular and hemodialysis access lesions. IVUS was utilized as the solitary imaging modality to identify the graft stenosis and guide the placement of a 6 mm diameter angioplasty balloon. Two areas of stenosis were successfully dilated and subsequent IVUS re-examination showed abolition of the stenosis. Twelve-month follow-up surveillance scan showed that the graft remained functional with good flow rates. In the setting of contrast allergy, IVUS may provide a valid and safe tool in the localization and treatment of peripheral vessel stenosis, including arteriovenous fistula angioplasty. To our knowledge this is the first reported use of IVUS for hemodialysis graft salvage adopting a completely 'contrast-free' technique. More studies are required to establish the true role of IVUS in the management of hemodialysis access angioplasty, but this successful case contributes valuable information to the literature on its clinical application.

  1. A random walk-based method for segmentation of intravascular ultrasound images

    Science.gov (United States)

    Yan, Jiayong; Liu, Hong; Cui, Yaoyao

    2014-04-01

    Intravascular ultrasound (IVUS) is an important imaging technique that is used to study vascular wall architecture for diagnosis and assessment of the vascular diseases. Segmentation of lumen and media-adventitia boundaries from IVUS images is a basic and necessary step for quantitative assessment of the vascular walls. Due to ultrasound speckles, artifacts and individual differences, automated segmentation of IVUS images represents a challenging task. In this paper, a random walk based method is proposed for fully automated segmentation of IVUS images. Robust and accurate determination of the seed points for different regions is the key to successful use of the random walk algorithm in segmentation of IVUS images and is the focus of our work. The presented method mainly comprises five steps: firstly, the seed points inside the lumen and outside the adventitia are roughly estimated with intensity information, respectively; secondly, the seed points outside the adventitia are refined, and those of the media are determined through the results of applying random walk to the IVUS image with the roughly estimated seed points; thirdly, the media-adventitia boundary is detected by using random walk with the seed points obtained in the second step and the image gradient; fourthly, the seed points for media and lumen are refined; finally, the lumen boundary is extracted by using random walk again with the seed points obtained in the fourth step and the image gradient. The tests of the proposed algorithm on the in vivo dataset demonstrate the effectiveness of the presented IVUS image segmentation approach.

  2. Introducing nuclei scatterer patterns into histology based intravascular ultrasound simulation framework

    Science.gov (United States)

    Kraft, Silvan; Karamalis, Athanasios; Sheet, Debdoot; Drecoll, Enken; Rummeny, Ernst J.; Navab, Nassir; Noël, Peter B.; Katouzian, Amin

    2013-03-01

    Medical ultrasonic grayscale images are formed from acoustic waves following their interactions with distributed scatterers within tissues media. For accurate simulation of acoustic wave propagation, a reliable model describing unknown parameters associated with tissues scatterers such as distribution, size and acoustic properties is essential. In this work, we introduce a novel approach defining ultrasonic scatterers by incorporating a distribution of cellular nuclei patterns in biological tissues to simulate ultrasonic response of atherosclerotic tissues in intravascular ultrasound (IVUS). For this reason, a virtual phantom is generated through manual labeling of different tissue types (fibrotic, lipidic and calcified) on histology sections. Acoustic properties of each tissue type are defined by assuming that the ultrasound signal is primarily backscattered by the nuclei of the organic cells within the intima and media of the vessel wall. This resulting virtual phantom is subsequently used to simulate ultrasonic wave propagation through the tissue medium computed using finite difference estimation. Subsequently B-mode images for a specific histological section are processed from the simulated radiofrequency (RF) data and compared with the original IVUS of the same tissue section. Real IVUS RF signals for these histological sections were obtained using a single-element mechanically rotating 40MHz transducer. Evaluation is performed by trained reviewers subjectively assessing both simulated and real B-mode IVUS images. Our simulation platform provides a high image quality with a very promising correlation to the original IVUS images. This will facilitate to better understand progression of such a chronic disease from micro-level and its integration into cardiovascular disease-specific models.

  3. In vitro atherosclerotic plaque and calcium quantitation by intravascular ultrasound and electron-beam computed tomography.

    Science.gov (United States)

    Gutfinger, D E; Leung, C Y; Hiro, T; Maheswaran, B; Nakamura, S; Detrano, R; Kang, X; Tang, W; Tobis, J M

    1996-05-01

    The purpose of this investigation was to compare the accuracy of intravascular ultrasound (IVUS) and electron-beam computed tomography (EBCT) in quantitating human atherosclerotic plaque and calcium. In experiment 1, 12 human atherosclerotic arterial segments were obtained at autopsy and imaged by using IVUS and EBCT. The plaque from each arterial segment was dissected and a volume measurement of the dissected plaque was obtained by water displacement. The plaque from each arterial segment was ashed at 700 degrees F, and the weight of the remaining ashes was used as an estimate of the calcium mass. In experiment II, 11 calcified arterial segments were obtained at autopsy and imaged by using IVUS at one site along the artery. A corresponding histologic cross section stained with Masson's trichrome was prepared. In experiment I, the mean plaque volume measured by water displacement was 165.3 +/- 118.4 microliters. The mean plaque volume calculated by IVUS was 166.1 +/- 114.4 microliters and correlated closely with that by water displacement (r = 0.98, p volume by IVUS was 18.6 +/- 11.2 microliters and correlated linearly with the calcium mass by ashing (r = 0.87, p volume as well as the cross-sectional area and volume of intralesional calcium, especially if the calcium is localized at the base of the plaque. IVUS underestimates the amount of calcium present because of signal drop-off when the calcium is too thick for the ultrasound to completely penetrate. In comparison, EBCT accurately quantitates calcium mass regardless of the intralesional calcium morphologic characteristics; however, EBCT does not accurately quantitate plaque volume and will miss noncalcified atherosclerotic lesions.

  4. Delineation of atherosclerotic plaque using subharmonic imaging filtering techniques and a commercial intravascular ultrasound system.

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R; Machado, Priscilla; deMuinck, Ebo D; Doyley, Marvin M; Forsberg, Flemming

    2013-01-01

    The ability to delineate atherosclerotic plaque from the surrounding tissue using custom-developed subharmonic imaging (SHI) digital filtering techniques was investigated in vivo using a commercially available system. Atherosclerosis was induced in the aorta of two Watanabe Heritable Hyperlipidemic rabbits following which injections of an ultrasound contrast agent (UCA) Definity (Lantheus Medical Imaging, N Billerica, Massachusetts) were administered. Imaging was performed using a Galaxy intravascular ultrasound (IVUS) scanner (Boston Scientific, Natick, Massachusetts) equipped with an Atlantis® SR Pro Imaging Catheter (Boston Scientific). Four preliminary band-pass filters were designed to isolate the subharmonic signal (from surrounding tissue) and applied to the radio-frequency (RF) data. Preliminary filter performances were compared in terms of vessel-tissue contrast-to-tissue ratio (CTR) and visual examination. Based on preliminary results, a subharmonic adaptive filter and a stopband (SB) filter were designed and applied to the RF data. Images were classified as fundamental, SHI, and SB. Four readers performed qualitative analysis of 168 randomly selected images (across all three imaging modes). The images were scored for overall image quality, image noise, plaque visualization, and vessel lumen visualization. A Wilcoxon signed-rank test was used to compare the scores followed by intraclass correlation (ICC) evaluation. Quantitative analysis was performed by calculating the CTRs for the vessel-to-plaque and vessel-to-tissue (compared using a paired student's t test). Qualitative analysis showed SHI and SB to have significantly less image noise relative to the fundamental mode (p < 0.001). Fundamental mode scored significantly higher than SHI and SB for the remaining three categories. ICC showed mixed results among reader evaluation for delineation of plaque. However, quantitatively, SHI produced the best vessel-plaque CTR.

  5. Percutaneous transradial coronary Palmaz-Schatz stent implantation, guided by intravascular ultrasound.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J; Slagboom, T

    1995-02-01

    Intravascular ultrasound (IVUS) allows accurate assessment of stent deployment, its use being confined to the use of 8 French (F) guiding catheters. We evaluated the feasibility of combining transradial artery Palmaz-Schatz stent implantation through 6F guiding catheters with IVUS for assessment of stent diameter after delivery at moderate inflation pressures (10-12 atmospheres [atm]) with compliant balloons and after high pressure dilatations with balloons of intermediate compliance. In 8 consecutive patients, 12 stents were delivered with Scimed Express balloon catheters at 10-12 atm followed by IVUS (EndoSonics CathScanner; Visions FX 3.5F 20 MHz transducer). An ultrasound study was repeated after high pressure dilatations (16-20 atm) with Schneider Magical Speedy balloon catheters. The balloon diameters were derived from manufacturer provided specifications. In all patients the transducer could easily be advanced through the guiding catheters. Reference diameter of the stented segment was 3.7 +/- 0.5 mm (2.7-4.5) and the diameter of Scimed Express balloons during inflation was 4.0 +/- 0.3 mm (3.6-4.7). Stent diameter was 3.0 +/- 0.1 mm (2.8-3.2) (P < 0.001 compared to the reference and the balloon diameter). The diameter of the Schneider Magical Speedy balloons at secondary dilatations with 16 +/- 3 atm (14-20) was 4.1 +/- 0.4 mm (3.3-4.5) (P = 0.50 compared to the initial balloon diameter). Final stent diameter was 3.3 +/- 0.4 mm (2.9-4.1) (P = 0.02 compared to the initial stent diameter). All stents were symmetrically deployed and well apposed. No damage to vessel or stents was detected after passage of the transducer.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. The virtual histology intravascular ultrasound appearance of newly placed drug-eluting stents.

    Science.gov (United States)

    Kim, Sang-Wook; Mintz, Gary S; Hong, Young-Joon; Pakala, Rajbabu; Park, Kyung-Sook; Pichard, Augusto D; Satler, Lowell F; Kent, Kenneth M; Suddath, William O; Waksman, Ron; Weissman, Neil J

    2008-11-01

    Intravascular ultrasound (IVUS) is used before and after intervention and at follow-up to assess the quality of the acute result as well as the long-term effects of stent implantation. Virtual histology (VH) IVUS classifies tissue into fibrous and fibrofatty plaque, dense calcium, and necrotic core. Although most interventional procedures include stent implantation, VH IVUS classification of stent metal has not been validated. In this study, the VH IVUS appearance of acutely implanted stents was assessed in 27 patients (30 lesions). Most stent struts (80%) appeared white (misclassified as "calcium") surrounded by red (misclassified as "necrotic core"); 2% appeared just white, and 17% were not detectable (compared with grayscale IVUS because of the software-imposed gray medial stripe). The rate of "white surrounded by red" was similar over the lengths of the stents; however, undetectable struts were mostly at the distal edges (31%). Quantitatively, including the struts within the regions of interest increased the amount of "calcium" from 0.23 +/- 0.35 to 1.07 +/- 0.66 mm(2) (p stents have an appearance that can be misclassified by VH IVUS as "calcium with or without necrotic core." It is important not to overinterpret VH IVUS studies of chronically implanted stents when this appearance is observed at follow-up. A separate classification for stent struts is necessary to avoid these misconceptions and misclassifications.

  7. Fast retrieval of calcification from sequential intravascular ultrasound gray-scale images.

    Science.gov (United States)

    Zheng, Sun; Bing-Ru, Liu

    2016-08-12

    Intravascular ultrasound (IVUS)-based tissue characterization is invaluable for the computer-aided diagnosis and interventional treatment of cardiac vessel diseases. Although the analysis of raw backscattered signals allows more accurate plaque characterization than gray-scale images, its applications are limited due to its nature of electrocardiogram-gated acquisition. Images acquired by IVUS devices that do not allow the acquisition of raw signals cannot be characterized. To address these limitations, we developed a method for fast frame-by-frame retrieval and location of calcification according to the jump features of radial gray-level variation curves from sequential IVUS gray-scale images. The proposed method consists of three main steps: (1) radial gray-level variation curves are extracted from each filtered polar view, (2) sequential images are preliminarily queried according to the maximal slopes of radial gray-level variation curves, and finally, (3) key frames that include calcification are selected through checking the gray-level features of successive pixel columns in the preliminary results. Experimental results with clinically acquired in vivo data sets indicate key frames that include calcification can be retrieved with the advantages of simplicity, high efficiency, and accuracy. Recognition results correlate well with manual characterization results obtained by experienced physicians and through virtual histology.

  8. Comparison of Segmental Versus Longitudinal Intravascular Ultrasound Analysis for Pediatric Cardiac Allograft Vasculopathy.

    Science.gov (United States)

    Kuhn, M A; Burch, M; Chinnock, R E; Fenton, M J

    2017-10-01

    Intravascular ultrasound (IVUS) has been routinely used in some centers to investigate cardiac allograft vasculopathy in pediatric heart transplant recipients. We present an alternative method using more sophisticated imaging software. This study presents a comparison of this method with an established standard method. All patients who had IVUS performed in 2014 were retrospectively evaluated. The standard technique consisted of analysis of 10 operator-selected segments along the vessel. Each study was re-evaluated using a longitudinal technique, taken at every third cardiac cycle, along the entire vessel. Semiautomatic edge detection software was used to detect vessel imaging planes. Measurements included outer and inner diameter, total and luminal area, maximal intimal thickness (MIT), and intimal index. Each IVUS was graded for severity using the Stanford classification. All results were given as mean ± standard deviation (SD). Groups were compared using Student t test. A P value grading severity of cardiac allograft vasculopathy in pediatric heart transplant recipients. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging.

    Science.gov (United States)

    Li, Xiang; Ma, Teng; Tian, Jian; Han, Pengdi; Zhou, Qifa; Shung, K Kirk

    2014-07-01

    In this paper, we report the use of micromachined PbIn1/2Nb1/2O3-PbMg1/3Nb2/3O3-PbTiO 3 (PIN-PMNPT) single crystal 1-3 composite material for intravascular ultrasound (IVUS) imaging application. The effective electromechanical coupling coefficient kt(eff) of the composite was measured to be 0.75 to 0.78. Acoustic impedance was estimated to be 20 MRayl. Based on the composite, needle-type and flexible-type IVUS transducers were fabricated. The composite transducer achieved an 86% bandwidth at the center frequency of 41 MHz, which resulted in a 43 μm axial resolution. Ex vivo IVUS imaging was conducted to demonstrate the improvement of axial resolution. The composite transducer was capable of identifying the three layers of a cadaver coronary artery specimen with high resolution. The PIN-PMN-PT-based composite has superior piezoelectric properties comparable to PMN-PT-based composite and its thermal stability is higher than PMN-PT. PIN-PMN-PT crystal can be an alternative approach for fabricating high-frequency composite, instead of using PMN-PT.

  10. Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging.

    Science.gov (United States)

    Yoon, Sangpil; Williams, Jay; Kang, Bong Jin; Yoon, Changhan; Cabrera-Munoz, Nestor; Jeong, Jong Seob; Lee, Sang Goo; Shung, K Kirk; Kim, Hyung Ham

    2015-06-01

    A transducer with an angled and focused aperture for intravascular ultrasound imaging has been developed. The acoustic stack for the angled-focused transducer was made of PMN-PT single crystal with one matching layer, one protective coating layer, and a highly damped backing layer. It was then press-focused to a desired focal length and inserted into a thin needle housing with an angled tip. A transducer with an angled and unfocused aperture was also made, following the same fabrication procedure, to compare the performance of the two transducers. The focused and unfocused transducers were tested to measure their center frequencies, bandwidths, and spatial resolutions. Lateral resolution of the angled-focused transducer (AFT) improved more than two times compared to that of the angled-unfocused transducer (AUT). A tissue-mimicking phantom in water and a rabbit aorta tissue sample in rabbit blood were scanned using AFT and AUT. Imaging with AFT offered improved contrast, over imaging with AUT, of the tissue-mimicking phantom and the rabbit aorta tissue sample by 23 dB and 8 dB, respectively. The results show that AFT has strong potential to provide morphological and pathological information of coronary arteries with high resolution and high contrast.

  11. Micromachined PIN-PMN-PT Crystal Composite Transducer for High-Frequency Intravascular Ultrasound (IVUS) Imaging

    Science.gov (United States)

    Li, Xiang; Ma, Teng; Tian, Jian; Han, Pengdi; Zhou, Qifa; Shung, K. Kirk

    2015-01-01

    In this paper, we report the use of micromachined PbIn1/2Nb1/2O3–PbMg1/3Nb2/3O3–PbTiO3 (PIN-PMN-PT) single crystal 1–3 composite material for intravascular ultrasound (IVUS) imaging application. The effective electromechanical coupling coefficient kt(eff) of the composite was measured to be 0.75 to 0.78. Acoustic impedance was estimated to be 20 MRayl. Based on the composite, needle-type and flexible-type IVUS transducers were fabricated. The composite transducer achieved an 86% bandwidth at the center frequency of 41 MHz, which resulted in a 43 μm axial resolution. Ex vivo IVUS imaging was conducted to demonstrate the improvement of axial resolution. The composite transducer was capable of identifying the three layers of a cadaver coronary artery specimen with high resolution. The PIN-PMN-PT-based composite has superior piezoelectric properties comparable to PMN-PT-based composite and its thermal stability is higher than PMN-PT. PIN-PMN-PT crystal can be an alternative approach for fabricating high-frequency composite, instead of using PMN-PT. PMID:24960706

  12. The potential value of intravascular ultrasound imaging in diagnosis of aortic intramural hematoma

    Institute of Scientific and Technical Information of China (English)

    Wei Hu; Francois Schiele; Nicolas Meneveau; Marie-France Seronde; Pierre Legalery; Jean-Francois Bonneville; Sidney Chocron; Jean-Pierre Bassand

    2011-01-01

    Objective To evaluate the potential value of intravascular ultrasound (IVUS) imaging in the diagnosis of aortic intramural hematoma (AIH).Methods From September 2002 to May 2005,a consecutive series of 15 patients with suspected aortic dissection (AD) underwent both IVUS imaging and spiral computed tomography (CT).Six patients diagnosed as acute type B AIH by CT or IVUS composed the present study group.Results The study group consisted of five males and one female with mean age of 66 years old.All of them had chest or back pain.In one patient,CT omitted a localized AIH and an associated penetrating atherosclerotic ulcer (PAU),which were detected by IVUS.In another patient,CT mistaken a partly thrombosed false lumen as an AIH,whereas IVUS detected a subtle intimal tear and slow moving blood in the false lumen.In the four rest patients,both CT and IVUS made the diagnosis of AIH,however,IVUS detected three PAUs in three of them,only one of them was also detected by CT,and two of them escaped initial CT and were confirmed by follow up CT or magnetic resonance imaging.Conclusions IVUS imaging is a safe examination and has high accuracy in the diagnosis of AIH,particularly for diagnosing localized AIH,distinguishing AIH with thrombosed classic AD and detecting accompanied small PAUs.

  13. The potential value of intravascular ultrasound imaging in diagnosis of aortic intramural hematoma

    Science.gov (United States)

    Hu, Wei; Schiele, Francois; Meneveau, Nicolas; Seronde, Marie-France; Legalery, Pierre; Bonneville, Jean-Francois; Chocron, Sidney; Bassand, Jean-Pierre

    2011-01-01

    Objective To evaluate the potential value of intravascular ultrasound (IVUS) imaging in the diagnosis of aortic intramural hematoma (AIH). Methods From September 2002 to May 2005, a consecutive series of 15 patients with suspected aortic dissection (AD) underwent both IVUS imaging and spiral computed tomography (CT). Six patients diagnosed as acute type B AIH by CT or IVUS composed the present study group. Results The study group consisted of five males and one female with mean age of 66 years old. All of them had chest or back pain. In one patient, CT omitted a localized AIH and an associated penetrating atherosclerotic ulcer (PAU), which were detected by IVUS. In another patient, CT mistaken a partly thrombosed false lumen as an AIH, whereas IVUS detected a subtle intimal tear and slow moving blood in the false lumen. In the four rest patients, both CT and IVUS made the diagnosis of AIH, however, IVUS detected three PAUs in three of them, only one of them was also detected by CT, and two of them escaped initial CT and were confirmed by follow up CT or magnetic resonance imaging. Conclusions IVUS imaging is a safe examination and has high accuracy in the diagnosis of AIH, particularly for diagnosing localized AIH, distinguishing AIH with thrombosed classic AD and detecting accompanied small PAUs. PMID:22783309

  14. Detection of coronary plaques using MR coronary vessel wall imaging: validation of findings with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Gerretsen, Suzanne; Engelshoven, Jos M.A. van; Kooi, M.E. [Maastricht University Medical Centre, Department of Radiology, Maastricht (Netherlands); Maastricht University, Cardiovascular Research Institute Maastricht (CARIM), Maastricht (Netherlands); Kessels, Alfons G. [Maastricht University Medical Centre, Department of Clinical Epidemiology and Medical Technical Assessment, Maastricht (Netherlands); Nelemans, Patty J. [Maastricht University, Department of Epidemiology, Maastricht (Netherlands); Dijkstra, Jouke; Reiber, Johan H.C.; Geest, Rob J. van der [Leiden University Medical Centre, Department of Radiology, Division of image processing (LKEB), Leiden (Netherlands); Katoh, Marcus [HELIOS Clinic, Department of Diagnostic and Interventional Radiology, Krefeld (Germany); Waltenberger, Johannes [University of Muenster, Department of Cardiology and Angiology, Muenster (Germany); Botnar, Rene M. [King' s College, Imaging Sciences Division, London (United Kingdom); Leiner, Tim [Maastricht University Medical Centre, Department of Radiology, Maastricht (Netherlands); Maastricht University, Cardiovascular Research Institute Maastricht (CARIM), Maastricht (Netherlands); Utrecht University Medical Centre, Department of Radiology, Utrecht (Netherlands)

    2013-01-15

    Compared with X-ray coronary angiography (CAG), magnetic resonance imaging of the coronary vessel wall (MR-CVW) may provide more information about plaque burden and coronary remodelling. We compared MR-CVW with intravascular ultrasound (IVUS), the standard of reference for coronary vessel wall imaging, with regard to plaque detection and wall thickness measurements. In this study 17 patients with chest pain, who had been referred for CAG, were included. Patients underwent IVUS and MR-CVW imaging of the right coronary artery (RCA). Subsequently, the coronary vessel wall was analysed for the presence and location of coronary plaques. Fifty-two matching RCA regions of interest were available for comparison. There was good agreement between IVUS and MR-CVW for qualitative assessment of presence of disease, with a sensitivity of 94% and specificity of 76%. Wall thickness measurements demonstrated a significant difference between mean wall thickness on IVUS and MR-CVW (0.48 vs 1.24 mm, P < 0.001), but great heterogeneity between wall thickness measurements, resulting in a low correlation between IVUS and MR-CVW. MR-CVW has high sensitivity for the detection of coronary vessel wall thickening in the RCA compared with IVUS. However, the use of MRI for accurate absolute wall thickness measurements is not supported when a longitudinal acquisition orientation is used. (orig.)

  15. The Imaging Modulography Technique Revisited for High-Definition Intravascular Ultrasound: Theoretical Framework.

    Science.gov (United States)

    Tacheau, Antoine; Le Floc'h, Simon; Finet, Gérard; Doyley, Marvin M; Pettigrew, Roderic I; Cloutier, Guy; Ohayon, Jacques

    2016-03-01

    Mechanical characterization of atherosclerotic lesions remains an essential step for the detection of vulnerable plaques (VPs). Recently, an intravascular ultrasound (IVUS) elasticity reconstruction method (iMOD) has been tested in vivo by our group. The major limitation of iMOD is the need to estimate the strain field in the entire VP despite attenuated depth penetration signals when using high-definition (HD) IVUS systems. Therefore, an extended iMOD approach (E-iMOD) was designed and applied to coronary lesions of patients imaged in vivo with IVUS. The E-iMOD method (i) quantified necrotic core areas with a mean absolute relative error of 3.5 ± 3.5% and (ii) identified Young's moduli of the necrotic cores and fibrous regions with mean values of 5.7 ± 0.8 kPa and 794.5 ± 22.0 kPa instead of 5 kPa and 800 kPa, respectively. This study demonstrates the potential of the improved HD-IVUS modulography technique E-iMOD to characterize coronary VPs.

  16. Characterization of coronary plaques with combined use of intravascular ultrasound, virtual histology and optical coherence tomography

    Directory of Open Access Journals (Sweden)

    José Calabuig

    2010-09-01

    Full Text Available According to post-mortem studies, luminal thrombosis occurs from plaque rupture, erosion and calcified nodules. In vivo studies have found thin cap fibroatheroma (TCFA as the main vulnerable lesion, prone to rupture. Few data about other post-mortem lesions have been reported in vivo. Our main objective is to characterize in vivo the coronary plaques with intravascular ultrasound-virtual histology (IVUS-VH and optical coherence tomography (OCT, in order to detect not only thin cap fibroatheroma (TCFA, but also other possible vulnerable lesions. The secondary objective is to correlate these findings with clinical and analytical data. Twenty-five patients (18 stable submitted to coronary angiography were included in this pilot study. After angiography, the three vessels were studied (when possible with IVUS-VH and OCT. Plaque characteristics were correlated with clinical and analytical data. Forty-six lesions were analyzed. IVUS-VH detected significant necrotic core in 15 (3 were definite TCFA. OCT detected TCFA in 10 lesions, erosion in 6, thrombus in 5 and calcified nodule in 8. Possible vulnerable lesion was found in 61% of stable and 57% of unstable patients. Erosions and calcified nodules were only found in stable patients. Those with significant necrotic core had higher body mass index (P=0.016, higher levels of hs-CRP (P=0.019 and triglycerides (P=0.040. The higher the levels of hs-CRP, the larger the size of the necrotic core (r=0.69, P=0.003. Lesions with characteristics of vulnerability were detected by IVUS-VH and OCT in more than 50% of stable and unstable coronary patients. A significant necrotic core was mainly correlated with

  17. Effect of probucol on vascular remodeling due to atherosclerosis in rabbits: an intravascular ultrasound study

    Institute of Scientific and Technical Information of China (English)

    LI Ting-ting; XIE Yi; GUO Yuan; TIAN Hong-bo; ZHANG Jian-ning; PENG Jie; ZHANG Yun

    2011-01-01

    Background Probucol is known to reduce the development of atherosclerotic lesions, but its impact on vascular remodeling associated with de novo atherosclerosis is incompletely understood. We therefore examined the effect of probucol on vascular remodeling in a rabbit model of established atherosclerosis.Methods Aortic atherosclerosis was induced by a combination of endothelial injury and 10 weeks' atherogenic diet. Animals were then randomized to receive the foregoing diet without or with 1% (wt/wt) probucol for 16 weeks. At the end of week 26, in vivo intravascular ultrasound, pathological, immunohistochemical and gene expression studies were performed.Results Probucol significantly decreased vessel cross-sectional area, plaque area and plaque burden without effect on lumen area. More negative remodeling and less positive remodeling occurred in the abdominal aortas of probucol group than the control group (56% vs. 21%, 18% vs. 54%, respectively, both P<0.01). In addition, the probucol group showed a smaller mean remodeling index relative to the control group (0.93 ± 0.13 vs. 1.05 ±0.16, P<0.01). Furthermore, probucol treatment decreased macrophage infiltration, inhibited apoptosis of cells within plaques, and reduced the production of matrix metalloproteinases-2, -9, cathepsin K and cathepsin S (all P<0.01).Conclusions These findings suggest that probucol may attenuate the enlargement of atherosclerotic vessel walls and be associated with a negative remodeling pattern without affecting the lumen size. This effect may involve inhibition of extracellular matrix degradation and prevention of apoptosis in atherosclerotic plaques.

  18. Abnormal pulmonary artery stiffness in pulmonary arterial hypertension: in vivo study with intravascular ultrasound.

    Directory of Open Access Journals (Sweden)

    Edmund M T Lau

    Full Text Available BACKGROUND: There is increasing recognition that pulmonary artery stiffness is an important determinant of right ventricular (RV afterload in pulmonary arterial hypertension (PAH. We used intravascular ultrasound (IVUS to evaluate the mechanical properties of the elastic pulmonary arteries (PA in subjects with PAH, and assessed the effects of PAH-specific therapy on indices of arterial stiffness. METHOD: Using IVUS and simultaneous right heart catheterisation, 20 pulmonary segments in 8 PAH subjects and 12 pulmonary segments in 8 controls were studied to determine their compliance, distensibility, elastic modulus and stiffness index β. PAH subjects underwent repeat IVUS examinations after 6-months of bosentan therapy. RESULTS: AT BASELINE, PAH SUBJECTS DEMONSTRATED GREATER STIFFNESS IN ALL MEASURED INDICES COMPARED TO CONTROLS: compliance (1.50±0.11×10(-2 mm(2/mmHg vs 4.49±0.43×10(-2 mm(2/mmHg, p<0.0001, distensibility (0.32±0.03%/mmHg vs 1.18±0.13%/mmHg, p<0.0001, elastic modulus (720±64 mmHg vs 198±19 mmHg, p<0.0001, and stiffness index β (15.0±1.4 vs 11.0±0.7, p = 0.046. Strong inverse exponential associations existed between mean pulmonary artery pressure and compliance (r(2 = 0.82, p<0.0001, and also between mean PAP and distensibility (r(2 = 0.79, p = 0.002. Bosentan therapy, for 6-months, was not associated with any significant changes in all indices of PA stiffness. CONCLUSION: Increased stiffness occurs in the proximal elastic PA in patients with PAH and contributes to the pathogenesis RV failure. Bosentan therapy may not be effective at improving PA stiffness.

  19. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, José Albuquerque Neto de, E-mail: jafneto@cardiol.br; Nogueira, Iara Antonia Lustosa [Universidade Federal do Maranhão, São Luiz, MA (Brazil); Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo, SP (Brazil)

    2013-08-15

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I{sup 2} test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I{sup 2} = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I{sup 2} = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I{sup 2} = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I{sup 2} = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes.

  20. Compensatory enlargement in transplant coronary artery disease: an intravascular ultrasound study

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background It is unclear to what extent the "Glagov phenomenon" occurs in transplant coronary artery disease (TCAD). The objective of this study was to evaluate the relationship between intimal hyperplasia and compensatory enlargement in TCAD. Methods Intravascular ultrasound imaging was performed on 190 cardiac transplant recipients at (1.4±0.6) months and again (12.1±0.7) months after cardiac transplantation. Studies 1 year apart were matched at 625 sites. There were 345 coronary artery sites that had an increase in intimal area >10% from baseline to one year, and this comprised the data set of the present study. Results At the first year, 91% of coronary artery sites with intimal growth had a total cross-sectional area stenosis ≤40%, but 38% of the sites showed a decrease of >10% in lumen area. Receiver operating characteristic curve demonstrated that the change in cross-sectional area stenosis cut-off level at year 1 was 8% with a sensitivity of 75% and a specificity of 82% in predicting lumen loss. At a total cross-sectional area stenosis of 20%, sensitivity was 65% with a specificity of 81% in predicting lumen loss. Conclusions In TCAD, vessel enlargement as a compensatory mechanism for plaque growth is generally inadequate. Instead of continued vessel expansion, luminal narrowing develops when there is more than 8% cross-sectional area filled with intimal hyperplasia. In distinction to native coronary artery atherosclerotic disease, the transition point in transplant vasculopathy where the lumen is diminished by increasing intimal growth, occurs at a lower threshold, 20% vs 40% of vessel cross-sectional area.

  1. Myocardial bridging detection by non-invasive multislice spiral computed tomography: comparison with intravascular ultrasound

    Institute of Scientific and Technical Information of China (English)

    WANG Ming-hui; ZHANG Feng; Raimund Erbel; GE Jun-bo; SUN Ai-jun; QIAN Ju-ying; LING Qing-zhi; ZENG Meng-su; GE Lei; WANG Ke-qiang; FAN Bing; YAN Wei

    2008-01-01

    Background Invasive intravascular ultrasound (IVUS) is current dlagnostic Standard for myocardial bridging (MB).Non-invasive multislice computerized tomography coronary angiography (MSCT) technique has provided a good anatomical view of the tunnel arten/ now.Methods A total of 51 consecutive patients with atypical or typical angina scheduled for IVUS were enrolled in this study and MSCT was performed 7 days before IVUS. Coronary imaging was quantified using IVUS and MSCT. Four main vessels (left main artery (LMA), left anterior descending (LAD), left circumflex (LCX), right coronary artery (RCA)) were examined.Results Forty-one out of 51 (80%) patients received metaprolol (25 mg) before the MSCT scan and 25 of them were current beta-blocker users. The mean heart rate was (64±3) beats per minute. A total of 51 patients underwent IVUS examination (30 with MB and 21 without MB) were chosen for this study. Twenty-eight out of 30 MB cases were correctly diagnosed by MSCT and 2 patients with MB were not detected. Comparison with IVUS, the sensitivity of detection by MSCT was 93%, specificity was 100%. The lumen diameter of the tunnel artery derived from MSCT and IVUS significantly decreased from (2.9±0.3) mm to (2.4±0.4) mm (P<0.001) and from (3.3±0.3) mm to (2.6±0.5) mm (P<0.001),respectively. Minimal and maximal diameters of MB derived from MSCT were significantly smaller than those from IVUS ((2.4±0.4) mm vs (2.6±0.5) mm, P<0.05 and (2.9±0.3) mm vs (3.3±0.3) mm, P<0.05), respectively.Conclusions MSCT offers a reliable non-invasive method for MB in LAD and atherosclerosis diagnosis with diagnostic accuracy comparable with invasive IVUS.

  2. Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.

    Science.gov (United States)

    Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent; Ghovanloo, Maysam

    2017-04-01

    Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 [Formula: see text] in a 0.35- [Formula: see text] standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed.

  3. Coronary venous lead implantation after an evaluation by virtual histology intravascular ultrasound and stenting of a stenosis.

    Science.gov (United States)

    Yamasaki, Hiro; Tada, Hiroshi; Arimoto, Takanori; Sekiguchi, Yukio; Sato, Akira; Aonuma, Kazutaka

    2013-02-01

    We describe a patient who developed coronary vein (CV) stenosis shortly (virtual histological intravascular ultrasound analysis was useful for characterizing the plaque component of the stenotic lesion and formulating the strategy. A summarized review of the CV angioplasty for LV lead implantations disclosed that CV stenosis was often found in patients who had a previous history of cardiac surgery or an LV lead implantation and that a stent implantation was required to deploy the LV lead in the targeted CV in some (9.3%) patients.

  4. [Comparison of Atherosclerotic Lesions in Patients With Acute Myocardial Infarction and Stable Angina Pectoris Using Intravascular Ultrasound].

    Science.gov (United States)

    Tagieva, N R; Shakhnovich, R M; Mironov, V M; Yezhov, M V; Matchin, Yu G; Mitroshkin, M G; Safarova, M S; Shitov, V N; Ruda, M Ya

    2015-07-01

    to compare noninfarct-related lesions in patients with acute myocardial infarction (MI) with culprit and non-culprit lesions in patients with stable angina pectoris (SAP) using intravascular ultrasound virtual histology (VH-IVUS). Overall 70 patients were enrolled: 38 with ST elevation (STE) MI and 32 with stable angina pectoris (SAP). All patients underwent three-vessel coronary angiography and gray-scale and VH-IVUS after percutaneous coronary intervention (PCI) of infarct-related lesion in STEMI or culprit lesion in SAP.

  5. Effect of Intravascular Ultrasound-assisted Thoracic Endovascular Aortic Repair for "Complicated" Type B Aortic Dissection

    Institute of Scientific and Technical Information of China (English)

    Bao-Lei Guo; Zhen-Yu Shi; Da-Qiao Guo; Li-Xin Wang; Xiao Tang; Wei-Miao Li; Wei-Guo Fu

    2015-01-01

    Background:Intravascular ultrasound (IVUS) examination can provide useful information during endovascular stent graft repair.However,its actual clinical utility in thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (type B-AD) remains unclear,especially in complicated aortic dissection.We evaluated the effect of IVUS as a complementary tool during TEVAR.Methods:From September 2011 to April 2012,we conducted a prospective cohort study of 47 consecutive patients with "complicated" type B-AD diagnosed.We divided the patients into two groups:IVUS-assisted TEVAR group and TEVAR using angiography alone group.The general procedure of TEVAR was performed.We evaluated the perioperative and follow-up events.Patient demographics,comorbidities,preoperative images,dissection morphology,details of operative strategy,intraoperative events,and postoperative course were recorded.Results:A total of 47 patients receiving TEVAR were enrolled.Among them (females,8.51%;mean age,57.38 ± 13.02 years),13 cases (27.66%) were selected in the IVUS-assisted TEVAR group,and 34 were selected in the TEVAR group.All patients were symptomatic.The average diameter values of IVUS measurements in the landing zone were greater than those estimated by computed tomography angiography (31.82 ± 4.21 mm vs.30.64 ± 4.13 mm,P < 0.001).The technique success rate was 100%.Among the postoperative outcomes,statistical differences were only observed between the IVUS-assisted TEVAR group and TEVAR group for total operative time and the amount of contrast used (P =0.013 and P < 0.001,respectively).The follow-up ranged from 15 to 36 months for the IVUS-assisted TEVAR group and from 10 to 35 months for the TEVAR group (P =0.646).The primary endpoints were no statistical difference in the two groups.Conclusions:Intraoperative IVUS-assisted TEVAR is clinically feasible and safe.For the endovascular repair of"complicated" type B-AD,IVUS may be helpful for understanding dissection

  6. Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented

    DEFF Research Database (Denmark)

    Huisman, Jennifer; Egede, Rasmus; Rdzanek, Adam

    2012-01-01

    To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibili...... on average the highest measurement reproducibility. A central analysis for VH-IVUS multicenter studies of lesions prior to PCI should be pursued. Moreover, it may be problematical to pool VH-IVUS data of individual trials analyzed by independent centers.......To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibility...... of volumetric VH-IVUS measurements, experienced analysts of 4 European IVUS centers performed independent analyses (in total 8,052 cross-sectional analyses) to obtain volumetric data of 40 coronary segments (length 20.0 ± 0.3 mm) from target lesions prior to percutaneous intervention that were performed...

  7. ECG-Gated Three-dimensional Intravascular Ultrasound : Feasibility and Reproducibility of the Automated Analysis of Coronary Lumen and Atherosclerotic Plaque Dimensions in Humans

    NARCIS (Netherlands)

    C. von Birgelen (Clemens); E.A. de Vrey (Evelyn); G.S. Mintz (Gary); A. Nicosia; N. Bruining (Nico); W. Li (Wenguang); P.W.J.C. Serruys (Patrick); P.J. de Feyter (Pim); J.R.T.C. Roelandt (Jos); C.J. Slager (Cornelis)

    1997-01-01

    textabstractBackground Automated systems for the quantitative analysis of three-dimensional (3D) sets of intravascular ultrasound (IVUS) images have been developed to reduce the time required to perform volumetric analyses; however, 3D image reconstruction by these nongated systems is frequently

  8. The Impact of the Acute Results on the Long - Term Outcome after the Treatment of In- stent Restenosis: A Serial Intravascular Ultrasound Study

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    @@ Stenting reduces acute complications and restenosis compared to balloon angioplasty and other devices. However, in- stent restenosis (ISR) is an important clinical problem. The current serial intravascular ultrasound (IVUS)analysis was undertaken to determine whether the acute results obtained during the treatment of ISR influence the long term results and whether this is true for patients treated with and without adjunct brachytherapy.

  9. Intravascular ultrasound as a novel tool for the diagnosis and targeted treatment of functional popliteal artery entrapment syndrome

    Directory of Open Access Journals (Sweden)

    Anna E. Boniakowski, MD

    2017-06-01

    Full Text Available Functional popliteal artery entrapment syndrome can be difficult to diagnose, as the imaging modalities presently employed are designed to detect anatomic entrapment. We describe a novel imaging technique to aid in diagnosis in this cohort. A 22-year-old cyclist presented with exercise-limiting claudication. Magnetic resonance angiography with provocative maneuvers was nondiagnostic. Digital subtraction angiography revealed long-segment occlusion of the popliteal artery with plantar flexion; however, the specific site of compression remained unclear. Intravascular ultrasound allowed specific localization of compression and further confirmed the diagnosis. Thus, we report this as an adjunctive imaging modality to definitively diagnose functional popliteal artery entrapment syndrome and to assist in operative planning.

  10. Fully integrated optical coherence tomography, ultrasound, and indocyanine green-based fluorescence tri-modality system for intravascular imaging.

    Science.gov (United States)

    Li, Yan; Jing, Joseph; Qu, Yueqiao; Miao, Yusi; Zhang, Buyun; Ma, Teng; Yu, Mingyue; Zhou, Qifa; Chen, Zhongping

    2017-02-01

    We present a tri-modality imaging system and fully integrated tri-modality probe for intravascular imaging. The tri-modality imaging system is able to simultaneously acquire optical coherence tomography (OCT), ultrasound (US), and fluorescence imaging. Moreover, for fluorescence imaging, we used the FDA-approved indocyanine green (ICG) dye as the contrast agent to target lipid-loaded macrophages. We conducted imaging from a male New Zealand white rabbit to evaluate the performance of the tri-modality system. In addition, tri-modality images of rabbit aortas were correlated with hematoxylin and eosin (H&E) histology to check the measurement accuracy. The fully integrated miniature tri-modality probe, together with the use of ICG dye suggest that the system is of great potential for providing a more accurate assessment of vulnerable plaques in clinical applications.

  11. Head to head comparison of optical coherence tomography, intravascular ultrasound echogenicity and virtual histology for the detection of changes in polymeric struts over time

    DEFF Research Database (Denmark)

    Brugaletta, Salvatore; Gomez-Lara, Josep; Bruining, Nico

    2012-01-01

    To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the A......To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation....... In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity...

  12. Mode of deployment of coronary Palmaz-Schatz stents after implantation with the stent delivery system: an intravascular ultrasound study.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G; Slagboom, T

    1995-04-01

    The stent delivery system (SDS) is a sheath-covered Palmaz-Schatz stent mounted on a 3.0, 3.5, or 4.0 mm compliant polyethylene balloon catheter; the balloon resists maximal inflation pressures of 5.7, 6.2, or 6.0 atm, respectively. It is postulated that these pressures are too low to obtain optimal stent deployment. Because optimal stent deployment is a prerequisite for optimal short- and long-term outcome, we performed an intravascular ultrasound study to the mode of stent deployment after delivery with the SDS and after high-pressure dilatations with low-compliant, oversized balloon catheters. In 23 patients an intravascular ultrasound study (30 MHz, 4.3F transducer) was performed to the geometry of 29 stents immediately after delivery with the SDS and after successive high-pressure inflations with low-compliant balloons. After delivery with the SDS (3.3 +/- 0.4 mm), stent diameter was 3.0 +/- 0.4 mm. After high-pressure dilatations (12.4 +/- 1.4 atm) with low-compliant balloons (3.9 +/- 0.5 mm), stent diameter increased to 3.4 +/- 0.4 mm (p < 0.001). Only 8 (28%) stents were completely and symmetrically expanded to the corresponding reference diameter with good apposition after delivery with the SDS. Diameter of incomplete deployed stents (n = 16) was 2.8 +/- 0.3 mm. After high-pressure dilatations with low-compliant balloons (3.9 +/- 0.5 mm), diameter increased to 3.4 +/- 0.4 mm (p < 0.001). Now 20 (69%) stents (p = 0.004) became completely and symmetrically expanded to a diameter corresponding to the reference diameter. In conclusion, most stents are suboptimally deployed after delivery with the stent delivery system.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Accuracy of Intravascular Ultrasound Evaluation for the Assessment of Native Valve Measures in Patients Undergoing TAVI: Preliminary Results.

    Science.gov (United States)

    de Cillis, Emanuela; Dachille, Annamaria; Giardinelli, Francesco; Acquaviva, Tommaso; Bortone, Alessandro Santo

    2016-10-26

    Transcatheter aortic valve implantation (TAVI) technique represents a real revolution in the field of interventional cardiology and medicine, in particular for the treatment of severe aortic valve stenosis in elderly patients or in patients when the periprocedural risk for the traditional surgical option is considered too high, as an alternative to the traditional aortic valve replacement. Although experience on the valves of the last generation is still limited in terms of time, the data currently available are definitely moving in the direction of a minimum hospital mortality (1%) as well as a drastic reduction in the incidence of complications when compared to the devices of the previous generation. Finally, the evolution of specified materials of the newest generation have greatly enhanced safety and efficacy of TAVI procedures in the last years. In order to ensure the selection of the most appropriate valve and the success of the procedure, the role of cardiac imaging (computed tomography scan evaluation and angiography) is crucial. These examinations require the use of contrast medium in patients suffering from renal dysfunction at the baseline. The need for fluoroscopy and angiography using contrast agents to aid positioning of the valve may lead to contrast-induced nephropathy (CIN) as one form or one etiology of acute kidney injury (AKI), which is associated with increased morbidity and mortality. The aim of our study is to investigate the accuracy of intravascular ultrasound (IVUS-a technique which does not need contrast) for the assessment of native valve measures in patients undergoing TAVI by comparing values obtained with IVUS to those ones previously obtained in the same patients with computed tomography (CT) scans. We enrolled 25 consecutive patients (10 males, average age 81.3±5,1 years) who underwent TAVI with femoral access in our Cardiac Surgery Cath-Lab (University of Bari) from January to October 2015 (Logistic EuroSCORE 21.6±15.4%; STS

  14. Virtual histology-intravascular ultrasound assessment of lesion coverage after angiographically-guided stent implantation in patients with ST Elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    Science.gov (United States)

    Legutko, Jacek; Jakala, Jacek; Mintz, Gary S; Wizimirski, Marcin; Rzeszutko, Lukasz; Partyka, Lukasz; Mrevlje, Blaz; Richter, Angela; Margolis, Pauliina; Kaluza, Grzegorz L; Dudek, Dariusz

    2012-05-15

    An occlusion or severe stenosis (angiographic culprit lesion) of the infarct-related artery is frequently located at the site of the maximum thrombus burden, whereas the origin of the plaque rupture (the true culprit) can be situated proximal or distal to it. The aim of this study was to examine stent coverage of true culprit lesions in 20 patients who underwent primary percutaneous coronary intervention and had Thrombolysis In Myocardial Infarction (TIMI) grade 3 flow restored in the infarct-related artery by angiographically guided direct stenting. Images of lesions were obtained using virtual histology-intravascular ultrasound before and after intervention (blinded to the operator). Plaque rupture sites were identified by intravascular ultrasound in 12 lesions (60%), 11 proximal and 1 distal to the minimum luminal area (MLA). Maximum necrotic core sites were found proximal to the MLA in 16 lesions, at the MLA in 3 lesions, and distal to the MLA in 1 lesion. Plaque rupture sites were fully covered by stents in 11 lesions. Virtual histology-intravascular ultrasound-derived thin-cap fibroatheroma longitudinal geographic misses were found in 10 lesions, 7 in the proximal reference segment and in 3 patients in the proximal and distal reference segments. In conclusion, in about 50% of patients who undergo primary percutaneous coronary intervention for ST-segment elevation myocardial infarction with optimal angiographic results, the stent does not fully cover the maximum necrotic core site related to the culprit lesion.

  15. Relation between baseline plaque features and subsequent coronary artery remodeling determined by optical coherence tomography and intravascular ultrasound.

    Science.gov (United States)

    Xie, Zulong; Dong, Nana; Sun, Rong; Liu, Xinxin; Gu, Xia; Sun, Yong; Du, Hongwei; Dai, Jiannan; Liu, Youbin; Hou, Jingbo; Tian, Jinwei; Yu, Bo

    2017-01-17

    Atherosclerosis often leads to myocardial infarction and stroke. We examined the influence of baseline plaque characteristics on subsequent vascular remodeling in response to changes in plaque size. Using optical coherence tomography (OCT) and intravascular ultrasound (IVUS), we examined 213 plaques from 138 patients with acute coronary syndrome at baseline and repeated IVUS at the 12-month follow-up. The change in external elastic membrane (EEM) area for each 1 mm2 change in plaque area (i.e., the slope of the regression line) was calculated as a measure of vascular remodeling capacity. In plaques with static positive remodeling, the slope was smaller than in plaques without static positive remodeling. In addition, the slope of the regression line for lesions with a large plaque burden was much smaller than that for lesions with a small plaque burden. Multivariate linear regression analysis showed that diabetes, calcification and static positive remodeling were inversely and independently associated with the level of change in EEM area/change in plaque area. Lesions with a large plaque burden, calcifications or static positive remodeling had less remodeling capacity, and calcification and static positive remodeling were independent predictors of reduced subsequent remodeling. Therefore, calcifications and static positive remodeling could be used as morphological biomarkers to predict decreased subsequent arterial remodeling.

  16. Clinical feasibility of 3D automated coronary atherosclerotic plaque quantification algorithm on coronary computed tomography angiography: Comparison with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyung-Bok [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); Myongji Hospital, Division of Cardiology, Cardiovascular Center, Goyang (Korea, Republic of); Lee, Byoung Kwon [Yonsei University College of Medicine, Division of Cardiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Shin, Sanghoon [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); National Health Insurance Corporation Ilsan Hospital, Division of Cardiology, Goyang (Korea, Republic of); Heo, Ran; Chang, Hyuk-Jae; Chung, Namsik [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); Yonsei University Health System, Division of Cardiology, Severance Cardiovascular Hospital, Seoul (Korea, Republic of); Arsanjani, Reza [Cedars-Sinai Medical Center, Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Los Angeles, CA (United States); Kitslaar, Pieter H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical Imaging Systems B.V., Leiden (Netherlands); Broersen, Alexander; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Ahn, Sung Gyun [Yonsei University Wonju Severance Christian Hospital, Division of Cardiology, Wonju (Korea, Republic of); Min, James K. [New York-Presbyterian Hospital, Institute for Cardiovascular Imaging, Weill-Cornell Medical College, New York, NY (United States); Hong, Myeong-Ki; Jang, Yangsoo [Yonsei University Health System, Division of Cardiology, Severance Cardiovascular Hospital, Seoul (Korea, Republic of)

    2015-10-15

    To evaluate the diagnostic performance of automated coronary atherosclerotic plaque quantification (QCT) by different users (expert/non-expert/automatic). One hundred fifty coronary artery segments from 142 patients who underwent coronary computed tomography angiography (CCTA) and intravascular ultrasound (IVUS) were analyzed. Minimal lumen area (MLA), maximal lumen area stenosis percentage (%AS), mean plaque burden percentage (%PB), and plaque volume were measured semi-automatically by expert, non-expert, and fully automatic QCT analyses, and then compared to IVUS. Between IVUS and expert QCT analysis, the correlation coefficients (r) for the MLA, %AS, %PB, and plaque volume were excellent: 0.89 (p < 0.001), 0.84 (p < 0.001), 0.91 (p < 0.001), and 0.94 (p < 0.001), respectively. There were no significant differences in the mean parameters (all p values >0.05) except %AS (p = 0.01). The automatic QCT analysis showed comparable performance to non-expert QCT analysis, showing correlation coefficients (r) of the MLA (0.80 vs. 0.82), %AS (0.82 vs. 0.80), %PB (0.84 vs. 0.73), and plaque volume (0.84 vs. 0.79) when they were compared to IVUS, respectively. Fully automatic QCT analysis showed clinical utility compared with IVUS, as well as a compelling performance when compared with semiautomatic analyses. (orig.)

  17. Impact of Indoxyl Sulfate, a Uremic Toxin, on Non-Culprit Coronary Plaque Composition Assessed on Integrated Backscatter Intravascular Ultrasound.

    Science.gov (United States)

    Yamazaki, Hiromu; Yamaguchi, Koji; Soeki, Takeshi; Wakatsuki, Tetsuzo; Niki, Toshiyuki; Taketani, Yoshio; Kitaoka, Atsunori; Kusunose, Kenya; Ise, Takayuki; Tobiume, Takeshi; Yagi, Shusuke; Iwase, Takashi; Yamada, Hirotsugu; Sata, Masataka

    2015-01-01

    Uremic toxin has emerged as an important determinant of cardiovascular risk. The aim of this study was to examine the relationship between serum uremic toxin and coronary plaque composition on integrated backscatter intravascular ultrasound (IB-IVUS). IB-IVUS was performed in 47 patients with planned treatment for angina pectoris. Non-culprit intermediate plaque analyzed in this study had to be >5 mm apart from the intervention site. 3-D IB-IVUS analysis was performed to determine percent lipid volume (LV) and fibrous volume (FV). We also measured serum uremic toxins (indoxyl sulfate [IS], asymmetric dimethylarginine [ADMA], and p-cresol [PC]). Glomerular filtration rate correlated with IS (r=-0.329, P=0.04), but did not correlate with ADMA or PC. Percent LV correlated with IS (r=0.365, P=0.02), but did not correlate with ADMA or PC. Percent FV also correlated with IS (r=-0.356, P=0.03), but did not correlate with ADMA or PC. On multivariate regression, only IS was associated with percent LV (r=0.359, P=0.04) and percent FV (r=-0.305, P=0.04) independently of potentially confounding coronary risk factors. Among the uremic toxins, serum IS might be a novel useful biomarker to detect and monitor lipid-rich coronary plaque on IB imaging.

  18. Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study

    Science.gov (United States)

    Gaster, A L; Slothuus Skjoldborg, U; Larsen, J; Korsholm, L; von Birgelen, C; Jensen, S; Thayssen, P; Pedersen, K E; Haghfelt, T H

    2003-01-01

    Objective: To investigate in a prospective randomised study both long term clinical effects and cost effectiveness of percutaneous coronary interventions (PCI) with or without intravascular ultrasound (IVUS) guidance. Methods: 108 male patients with stable angina referred for PCI of a significant coronary lesion were randomly assigned to IVUS guided PCI or conventional PCI. Individual accumulated costs of the entire follow up period were calculated and compared in the randomisation groups. Effectiveness of treatment was measured by freedom from major adverse cardiac events. Results: Cost effectiveness of IVUS guided PCI that was noted at six months was maintained and even accentuated at long term follow up (median 2.5 years). The cumulated cost level was found to be lower for the IVUS guided group, with a cumulated cost of &163 672 in the IVUS guided group versus &313 706 in the coronary angiography group (p = 0.01). Throughout the study, mean cost per day was lower in the IVUS guided PCI group (&2.7 v &5.2; p = 0.01). In the IVUS group, 78% were free from major adverse cardiac events versus 59% in the coronary angiography group (p = 0.04) with an odds ratio of 2.5 in favour of IVUS guidance. Conclusion: IVUS guidance results in continued improvement of long term clinical outcome and cost effectiveness. The results of this study suggest that IVUS guidance may be used more liberally in PCI. PMID:12923023

  19. INTRAVASCULAR ULTRASOUND EVALUATING CORONARY STENTS FOR PATIENTS WITH CORONARY ARTERY DISEASE: COMPARED OLD WITH NEW MULTILINK STENTS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective.It was suggested that coronary stent design and coating may affect stent performance and hence induce varying degrees of thrombogenesis and neointimal hyperplasia.The purpose of this study is to compare the 6 month follow up results between old and new Multilink stents with the method of intravascular ultrasound (IVUS) imaging.Methods.We have performed old (n=40) and new (n=35) Multilink stent implantations on 75 patients with coronary artery disease.Coronary angiography was performed before,immediately after,and 6 months after the in stent procedure respectively.Six month follow up IVUS imaging was performed and analyzed off line.Results.Minimal lumen cross sectional area (CSA) of new Multilink stents was significantly larger than that of old Multilink stents (P=0.0053).Mean stent lumen area of new Multilink stents was significantly larger than that of old Multilink stents (P=0.040).Similarly,minimal lumen diameter (MLD) of new Multilink stents was larger than that of old Multilink stents (P= 0.011).Old Multilink stents had a higher percentage of plaque area than new Multilink stents.Conclusion.The new Multilink stent is obviously superior to old Multilink stents,in particular,in the stent MLD and lumen CSA- - major determinants of the restenosis.

  20. Supervised domain adaptation of decision forests: Transfer of models trained in vitro for in vivo intravascular ultrasound tissue characterization.

    Science.gov (United States)

    Conjeti, Sailesh; Katouzian, Amin; Roy, Abhijit Guha; Peter, Loïc; Sheet, Debdoot; Carlier, Stéphane; Laine, Andrew; Navab, Nassir

    2016-08-01

    In this paper, we propose a supervised domain adaptation (DA) framework for adapting decision forests in the presence of distribution shift between training (source) and testing (target) domains, given few labeled examples. We introduce a novel method for DA through an error-correcting hierarchical transfer relaxation scheme with domain alignment, feature normalization, and leaf posterior reweighting to correct for the distribution shift between the domains. For the first time we apply DA to the challenging problem of extending in vitro trained forests (source domain) for in vivo applications (target domain). The proof-of-concept is provided for in vivo characterization of atherosclerotic tissues using intravascular ultrasound signals, where presence of flowing blood is a source of distribution shift between the two domains. This potentially leads to misclassification upon direct deployment of in vitro trained classifier, thus motivating the need for DA as obtaining reliable in vivo training labels is often challenging if not infeasible. Exhaustive validations and parameter sensitivity analysis substantiate the reliability of the proposed DA framework and demonstrates improved tissue characterization performance for scenarios where adaptation is conducted in presence of only a few examples. The proposed method can thus be leveraged to reduce annotation costs and improve computational efficiency over conventional retraining approaches.

  1. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  2. 80-MHz intravascular ultrasound transducer using PMN-PT free-standing film.

    Science.gov (United States)

    Li, Xiang; Wu, Wei; Chung, Youngsoo; Shih, Wan Y; Shih, Wei-Heng; Zhou, Qifa; Shung, K Kirk

    2011-11-01

    [Pb(Mg(1/3)Nb(2/3))O(3)](0.63)[PbTiO(3)](0.37) (PMN-PT) free-standing film of comparable piezoelectric properties to bulk material with thickness of 30 μm has been fabricated using a modified precursor coating approach. At 1 kHz, the dielectric permittivity and loss were 4364 and 0.033, respectively. The remnant polarization and coercive field were 28 μC/cm(2) and 18.43 kV/cm. The electromechanical coupling coefficient k(t) was measured to be 0.55, which was close to that of bulk PMN-PT single-crystal material. Based on this film, high-frequency (82 MHz) miniature ultrasonic transducers were fabricated with 65% bandwidth and 23 dB insertion loss. Axial and lateral resolutions were determined to be as high as 35 and 176 μm. In vitro intravascular imaging on healthy rabbit aorta was performed using the thin film transducers. In comparison with a 35-MHz IVUS transducer, the 80-MHz transducer showed superior resolution and contrast with satisfactory penetration depth. The imaging results suggest that PMN-PT free-standing thin film technology is a feasible and efficient way to fabricate very-high-frequency ultrasonic transducers.

  3. Combined chirp coded tissue harmonic and fundamental ultrasound imaging for intravascular ultrasound: 20-60 MHz phantom and ex vivo results.

    Science.gov (United States)

    Park, Jinhyoung; Li, Xiang; Zhou, Qifa; Shung, K Kirk

    2013-02-01

    The application of chirp coded excitation to pulse inversion tissue harmonic imaging can increase signal to noise ratio. On the other hand, the elevation of range side lobe level, caused by leakages of the fundamental signal, has been problematic in mechanical scanners which are still the most prevalent in high frequency intravascular ultrasound imaging. Fundamental chirp coded excitation imaging can achieve range side lobe levels lower than -60dB with Hanning window, but it yields higher side lobes level than pulse inversion chirp coded tissue harmonic imaging (PI-CTHI). Therefore, in this paper a combined pulse inversion chirp coded tissue harmonic and fundamental imaging mode (CPI-CTHI) is proposed to retain the advantages of both chirp coded harmonic and fundamental imaging modes by demonstrating 20-60MHz phantom and ex vivo results. A simulation study shows that the range side lobe level of CPI-CTHI is 16dB lower than PI-CTHI, assuming that the transducer translates incident positions by 50μm when two beamlines of pulse inversion pair are acquired. CPI-CTHI is implemented for a proto-typed intravascular ultrasound scanner capable of combined data acquisition in real-time. A wire phantom study shows that CPI-CTHI has a 12dB lower range side lobe level and a 7dB higher echo signal to noise ratio than PI-CTHI, while the lateral resolution and side lobe level are 50μm finer and -3dB less than fundamental chirp coded excitation imaging respectively. Ex vivo scanning of a rabbit trachea demonstrates that CPI-CTHI is capable of visualizing blood vessels as small as 200μm in diameter with 6dB better tissue contrast than either PI-CTHI or fundamental chirp coded excitation imaging. These results clearly indicate that CPI-CTHI may enhance tissue contrast with less range side lobe level than PI-CTHI. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Real-time intravascular ultrasound/photoacoustic imaging system with omni-directional light excitation

    Science.gov (United States)

    Hsieh, Bao-Yu; Li, Pai-Chi

    2012-02-01

    Photoacoustic (PA) imaging has been investigated for intravascular applications. One of the main challenges is that the imaging frame rate is limited by the pulse repetition frequency (PRF), thus making real-time imaging difficult with most high-power solid-state pulse lasers. The goal of this study is to combine omni-directional optical excitation with a ring array transducer for high-frame-rate imaging, so that the image frame rate is the same as the laser PRF. In the preliminary study, we developed a real-time integrated IVUS/IVPA imaging system by modifying an IVUS system in combination with a high-speed Nd:YLF pulsed laser. In addition, an optical fiber with axicon-like distal tip is designed for omni-directional excitation. In this design, a PA image is acquired without rotating the laser light. The imaging frame rate of this integrated imaging system is 19 fps. Both US and PA images are recorded at the same time and co-registered in the fusion image. The US/PA images of tungsten wire, black tube and rabbit's atherosclerotic aorta were acquired with this integrated system to evaluate its imaging performance. The lateral/axial -6 dB resolution of US image is 2.56°/62.4μm. Resolution of PA imaging is 3.76°/91.5μm. The imaging system was also utilized to acquire IVUS/IVPA images of atherosclerotic rabbit's aorta in ex vivo study.

  5. Volcanoes

    Science.gov (United States)

    ... or more from a volcano. Before a Volcanic Eruption The following are things you can do to ... in case of an emergency. During a Volcanic Eruption Follow the evacuation order issued by authorities and ...

  6. Invasive evaluation of plaque morphology of symptomatic superficial femoral artery stenoses using combined near-infrared spectroscopy and intravascular ultrasound.

    Science.gov (United States)

    Zacharias, Sibin K; Safian, Robert D; Madder, Ryan D; Hanson, Ivan D; Pica, Mark C; Smith, James L; Goldstein, James A; Abbas, Amr E

    2016-08-01

    The purpose of this study is to characterize the plaque morphology of severe stenoses in the superficial femoral artery (SFA) employing combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS). Atherosclerosis is the most common cause of symptomatic peripheral arterial disease. Plaque composition of SFA stenoses has been characterized as primarily fibrous or fibrocalcific by non-invasive and autopsy studies. NIRS has been validated to detect lipid-core plaque (LCP) in the coronary circulation. We imaged severe SFA stenoses with NIRS-IVUS prior to revascularization in 31 patients (46 stenoses) with Rutherford claudication ⩾ class 3. Angiographic parameters included lesion location and stenosis severity. IVUS parameters included plaque burden and presence of calcium. NIRS images were analyzed for LCP and maximum lipid-core burden index in a 4-mm length of artery (maxLCBI4mm). By angiography, 38 (82.6%) lesions were calcified and 9 (19.6%) were chronic total occlusions. Baseline stenosis severity and lesion length were 86.0 ± 11.0% and 36.5 ± 46.5 mm, respectively. NIRS-IVUS identified calcium in 45 (97.8%) lesions and LCP in 17 (37.0%) lesions. MaxLCBI4mm was 433 ± 244. All lesions with LCP also contained calcium; there were no non-calcified lesions with LCP. In conclusion, this is the first study of combined NIRS-IVUS in patients with PAD. NIRS-IVUS demonstrates that nearly all patients with symptomatic severe SFA disease have fibrocalcific plaque, and one-third of such lesions contain LCP. These findings contrast with those in patients with acute coronary syndromes, and may have implications regarding the pathophysiology of atherosclerosis in different vascular beds.

  7. Impact of intravascular ultrasound on the long-term clinical outcomes in the treatment of coronary ostial lesions.

    Science.gov (United States)

    Patel, Yogesh; Depta, Jeremiah P; Patel, Jayendrakumar S; Masrani, Shriti K; Novak, Eric; Zajarias, Alan; Kurz, Howard I; Lasala, John M; Bach, Richard G; Singh, Jasvindar

    2016-02-01

    To evaluate the long-term outcomes of patients with ostial lesions who underwent percutaneous coronary intervention (PCI) with and without the use of intravascular ultrasound (IVUS). A higher rate of adverse cardiac events is associated with PCI of ostial lesions as compared with nonostial disease. From 7/2002 to 8/2010, 225 patients with 233 coronary ostial lesions underwent PCI with (n = 82) and without (n = 143) IVUS guidance. Ostial lesions included both native aorto-ostial or major coronary vessel (left anterior descending, left circumflex, and ramus intermedius) lesions. Clinical outcomes [cardiovascular death, myocardial infarction (MI), and target lesion revascularization (TLR)] at a mean follow-up of 4.2 ± 2.5 years were compared between patients undergoing PCI of an ostial lesion with and without use of IVUS using univariate and propensity score adjusted analyses. Aorto-ostial lesions (n = 109) comprised 47% of lesions, whereas the remaining lesions (53%) involved major coronary vessels. After propensity score adjustment, IVUS use was associated with lower rates of the composite of cardiovascular death, MI, or TLR (HR 0.54, 95% CI 0.29-0.99; P = 0.04), composite MI or TLR (HR 0.39, 95% CI 0.18-0.83; P = 0.01), and MI (HR 0.31, 95% CI 0.11-0.85; P = 0.02) as compared with no IVUS. The use of IVUS was also associated with a trend towards a lower rate of TLR (HR 0.42, 95% CI 0.17-1.02; P = 0.06). PCI of coronary ostial lesions with the use of IVUS was associated with significantly lower rates of adverse cardiac events. © 2015 Wiley Periodicals, Inc.

  8. Coronary bifurcation lesions treated with double kissing crush technique compared to classical crush technique: serial intravascular ultrasound analysis.

    Science.gov (United States)

    Shan, Shou-Jie; Ye, Fei; Liu, Zhi-Zhong; Tian, Nai-Liang; Zhang, Jun-Jie; Chen, Shao-Liang

    2013-04-01

    The double kissing (DK) crush technique is a modified version of the crush technique. It is specifically designed to increase the success rate of the final kissing balloon post-dilatation, but its efficacy and safety remain unclear. Data were obtained from the DKCRUSH-I trial, a prospective, randomized, multi-center study to evaluate safety and efficacy. Post-procedural and eight-month follow-up intravascular ultrasound (IVUS) analysis was available in 61 cases. Volumetric analysis using Simpson's method within the Taxus stent, and cross-sectional analysis at the five sites of the main vessel (MV) and three sites of the side branch (SB) were performed. Impact of the bifurcation angle on stent expansion at the carina was also evaluated. Stent expansion in the SB ostium was significantly less in the classical crush group ((53.81 ± 13.51)%) than in the DK crush group ((72.27 ± 11.46)%) (P = 0.04). For the MV, the incidence of incomplete crush was 41.9% in the DK group and 70.0% in the classical group (P = 0.03). The percentage of neointimal area at the ostium had a tendency to be smaller in the DK group compared with the classical group ((16.4 ± 19.2)% vs. (22.8 ± 27.1)%, P = 0.06). The optimal threshold of post-procedural minimum stent area (MSA) to predict follow-up minimum lumen area (MLA) kissing balloon inflation (FKBI) and had smaller optimal cutoff value of post-procedural MSA at the SB ostium.

  9. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Carlier, Stéphane, E-mail: sgcarlier@hotmail.com [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium); Department of Cardiology, Erasme University Hospital, Université Libre de Bruxelles (ULB), Brussels (Belgium); Didday, Rich [INDEC Medical Systems Inc., Santa Clara, CA (United States); Slots, Tristan [Pie Medical Imaging BV, Maastricht (Netherlands); Kayaert, Peter; Sonck, Jeroen [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium); El-Mourad, Mike; Preumont, Nicolas [Department of Cardiology, Erasme University Hospital, Université Libre de Bruxelles (ULB), Brussels (Belgium); Schoors, Dany; Van Camp, Guy [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium)

    2014-06-15

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator’s identification of landmarks to establish the image synchronization.

  10. Capacitação de enfermeiros para uso da ultrassonografia na punção intravascular periférica Capacitación de enfermeros en el uso de la ultrasonografía en la punción intravascular periférica Training of nurses in the use of intravascular ultrasound in peripheral puncture

    Directory of Open Access Journals (Sweden)

    Ariane Ferreira Machado Avelar

    2010-06-01

    Full Text Available Este artigo relata a estratégia de capacitação de enfermeiros para uso da ultrassonografia vascular na obtenção do acesso vascular periférico. O programa foi composto por intervenções educacionais teóricas e práticas desenvolvidas em um período de seis meses. As estratégias foram elaboradas e implementadas por dois enfermeiros especialistas em terapia intravascular, um médico especialista em ultrassonografia vascular e um engenheiro biomédico. Oito enfermeiros participaram da capacitação e, ao final, os conhecimentos, as competências e habilidades adquiridas na identificação de artérias, veias, fluxo sanguíneo e posicionamento de cateteres foram avaliados. A estratégia possibilitou que enfermeiros pediatras adquirissem competências capazes de promover intervenções inovadoras na punção intravascular periférica.Este artículo relata la estrategia de capacitación de enfermeros en el uso de la ultrasonografía vascular en la obtención del acceso vascular periférico. El programa estuvo compuesto por intervenciones educacionales teóricas y prácticas desarrolladas en un período de seis meses. Las estrategias fueron elaboradas e implementadas por dos enfermeros especialistas en terapia intravascular, un médico especialista en ultrasonografía vascular y, un ingeniero biomédico. Ocho enfermeros participaron de la capacitación. Al final, los conocimientos, las competencias y habilidades adquiridas en la identificación de arterias, venas, flujo sanguíneo y posición de catéteres, fueron evaluados. La estrategia posibilitó que los enfermeros pediatras adquiriesen competencias capaces de promover intervenciones innovadoras en la punción intravascular periférica.The objective was to explain, to the nurses training, procedures using vascular ultrasound for obtaining peripheral vascular access. The program consisted of theoretical and practical educational interventions developed over a period of six months. The

  11. Prediction of Outcome after Femoropopliteal Balloon Angioplasty by Intervascular Ultrasound

    DEFF Research Database (Denmark)

    Schroeder, Torben Veith; Vogt, Katja; Just, S.;

    1997-01-01

    original, intravascular ultrasound, percutaneous transluminal angioplasty, peripheral arteries, plaquemorphology, prediction of outcome......original, intravascular ultrasound, percutaneous transluminal angioplasty, peripheral arteries, plaquemorphology, prediction of outcome...

  12. Discrepant findings of computed tomography quantification of minimal lumen area of coronary artery stenosis: Correlation with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yuehua, E-mail: andrewradiologist@hotmail.com [Department of Radiology, Shanghai No. 6 People' s Hospital, School of Medicine, Shanghai Jiaotong University, No. 600, Yishan Rd, Shanghai 200233 (China); Zhang, Jiayin, E-mail: andrewssmu@msn.com [Department of Radiology, Shanghai No. 6 People' s Hospital, School of Medicine, Shanghai Jiaotong University, No. 600, Yishan Rd, Shanghai 200233 (China); Lu, Zhigang, E-mail: andrewradiologist@gmail.com [Department of Cardiology, Shanghai No. 6 People' s Hospital, School of Medicine, Shanghai Jiaotong University (China); Pan, Jingwei, E-mail: andrewssmu@gmail.com [Department of Cardiology, Shanghai No. 6 People' s Hospital, School of Medicine, Shanghai Jiaotong University (China)

    2012-11-15

    Objectives: To study the diagnostic performance of computed tomography (CT) quantification of minimal lumen area (MLA) based on multiple factors (image quality, calcification and lesion locations), with reference to intravascular ultrasound (IVUS). Methods: Consecutive clinically ordered patients were prospectively enrolled in our study. CT quantification of MLA was manually measured on cross-sectional view and further compared with IVUS findings. A significant lesion was defined as {<=}6 mm{sup 2} MLA for the left main (LM) coronary artery and a {<=}4 mm{sup 2} MLA for other epicardial vessels. Results: Non-calcified lesions had good correlation between CT and IVUS (r = 0.96) and the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 85% (51/60), 93.94% (31/33), 96.23% (51/53) and 77.5% (31/40) respectively. Decreased correlation (r = 0.814) lower specificity (23.81% (5/21)) and positive predictive value (60.98% (25/41)) were observed in calcified subgroup. Artifact-absent lesions demonstrated excellent correlation (r = 0.967) and the sensitivity, specificity, PPV and NPV were 96% (48/50), 93.94% (31/33), 96% (48/50) and 93.94% (31/33) respectively. Impaired correlation (r = 0.584) was noted in artifact-present lesions and the sensitivity, specificity, PPV and NPV were 80% (28/35), 23.81% (5/21), 63.64% (28/44) and 41.67% (5/12) respectively. Excellent correlation between CT and IVUS was noted in proximal epicardial vessels (r = 0.908) and the sensitivity, specificity, PPV and NPV were 92.31% (36/39), 78.13% (25/32), 83.72% (36/43) and 89.29% (25/28) respectively. Middle right coronary artery lesions showed non-significant correlation (r = 0.54, p = 0.055). Conclusions: CT quantification of MLA can only be accurately achieved in non-calcified lesions with absence of artifact. Diagnostic performance is impaired in calcified lesions.

  13. Relationship among coronary plaque compliance, coronary risk factors and tissue characteristics evaluated by integrated backscatter intravascular ultrasound

    Directory of Open Access Journals (Sweden)

    Ishihara Yoshiyuki

    2012-07-01

    Full Text Available Abstract Background The purpose of the present study was to evaluate the mechanical properties of coronary plaques and plaque behavior, and to elucidate the relationship among tissue characteristics of coronary plaques, mechanical properties and coronary risk factors using integrated backscatter intravascular ultrasound (IB-IVUS. Methods Non-targeted plaques with moderate stenosis (plaque burden at the minimal lumen site: 50-70% located proximal to the site of the percutaneous coronary intervention target lesions were evaluated by IB-IVUS. Thirty-six plaques (less calcified group: an arc of calcification ≤10° in 36 patients and 22 plaques (moderately calcified group: 10°  Results In the less calcified group, there was a significant correlation between EEMV compliance and the relative lipid volume (r = 0.456, p = 0.005. There was a significant inverse correlation between EEM area stiffness index and the relative lipid volume (p = 0.032, r = −0.358. The LV compliance and EEM area stiffness index were significantly different in the diabetes mellitus (DM group than in the non-DM group (1.32 ± 1.49 vs. 2.47 ± 1.79%/10 mmHg, p =0.014 and 28.3 ± 26.0 vs. 15.7 ± 17.2, p =0.020. The EEMV compliance and EEM area stiffness index were significantly different in the hypertension (HTN group than in the non-HTN group (0.77 ± 0.68 vs. 1.57 ± 0.95%/10 mmHg, p =0.012 and 26.5 ± 24.3 vs. 13.0 ± 16.7, p =0.020. These relationships were not seen in the moderately calcified group. Conclusion The present study provided new findings that there was a significant correlation between mechanical properties and tissue characteristics of coronary arteries. In addition, our results suggested that the EEMV compliance and the LV compliance were independent and the compliance was significantly impaired in the patients with DM and/or HTN. Assessment of coronary mechanical properties during PCI may provide us with

  14. Coronary bifurcation lesions treated with double kissing crush technique compared to classical crush technique: serial intravascular ultrasound analysis

    Institute of Scientific and Technical Information of China (English)

    SHAN Shou-jie; YE Fei; LIU Zhi-zhong; TIAN Nai-liang; ZHANG Jun-jie; HEN Shao-liang

    2013-01-01

    Background The double kissing (DK) crush technique is a modified version of the crush technique.It is specifically designed to increase the success rate of the final kissing balloon post-dilatation,but its efficacy and safety remain unclear.Methods Data were obtained from the DKCRUSH-I trial,a prospective,randomized,multi-center study to evaluate safety and efficacy.Post-procedural and eight-month follow-up intravascular ultrasound (IVUS) analysis was available in 61 cases.Volumetric analysis using Simpson's method within the Taxus stent,and cross-sectional analysis at the five sites of the main vessel (MV) and three sites of the side branch (SB) were performed.Impact of the bifurcation angle on stent expansion at the carina was also evaluated.Results Stent expansion in the SB ostium was significantly less in the classical crush group ((53.81±13.51)%) than in the DK crush group ((72.27±11.46)%) (P=-0.04).For the MV,the incidence of incomplete crush was 41.9% in the DK group and 70.0% in the classical group (P=-0.03).The percentage of neointimal area at the ostium had a tendency to be smaller in the DK group compared with the classical group ((16.4±19.2)% vs.(22.8±27.1)%,P=-0.06).The optimal threshold of post-procedural minimum stent area (MSA) to predict follow-up minimum lumen area (MLA) <4.0 mm2 at the SB ostium was 4.55 mm2,yielding an area under the curve of 0.80 (95% confidence interval:0.61 to 0.92).Conclusion Our data suggest that the DK crush technique is associated with improved quality of the final kissing balloon inflation (FKBI) and had smaller optimal cutoff value of post-procedural MSA at the SB ostium.

  15. Relationship between hs-CRP, proMMP-1, TIMP-1 and coronary plaque morphology: intravascular ultrasound study

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xing-wei; ZHOU Liang; YE Xian-hua; XU Jian; GE Jun-bo; YANG Jian-min; GE Lei; WANG Ning-fu; GAO Yan; LI Pei-zhang; PAN Hao; TONG Guo-xin

    2006-01-01

    Background Rupture of unstable plaque with subsequent thrombus formation is the common pathophysiological substrate of the acute coronary syndrome (ACS). It is of potential significance to explore the blood indexes predicting plaque characteristics. Little studies have focused on this field. Therefore we investigated the relationship between hypersensitive C-reactive protein (hs-CRP), pro-matrix metalloproteinase-1 (proMMP-1),tissue inhibitors of matrix metalloproteinase-1 (TIMP-1) and coronary plaque morphology.Methods Intravascular ultrasound (IVUS) examination was done in 152 patients with confirmed coronary heart disease before percutaneous coronary intervention from February 2003 to July 2005. Plasma samples of arterial blood were collected prior to the procedure. The level of hs-CRP, proMMP-1 and TIMP-1 were respectively measured by enzyme-linked immunosorbent assay (ELISA).Results Unstable and ruptured plaque were found more frequently in patients with acute myocardial infarction and unstable angina. External elastic membrane cross-sectional area (EEM CSA), plaque area, lipid pool area and plaque burden were significantly larger in ruptured and unstable plaque group. Positive remolding, thinner frequent in ruptured and unstable plaque group. The levels of plasma hs-CRP, proMMP-1 and TIMP-1 were higher in ruptured plaque group. hs-CRP>8.94 mg/L was used to predict ruptured plaque with a ROC curve area of 0.76 [95% confidence interval (CI), 67.0%-85.8%], sensitivity of 71.8%, specificity of 77.0% and accuracy of 69.2% (P<0.01), similarly for proMMP-1>0.12 ng/ml with a ROC curve area of 0.69 [95% CI, 58.2%-80.2%], sensitivity of 69.2%, specificity of 75.2% and accuracy of 66.2% (P<0.01), and TIMP-1>83.45 ng/ml with a ROC curve area of 0.67 [95% CI, 56.2%-78.3%], sensitivity of 66.7%, specificity of 61.9% and accuracy of 66.2% (P<0.01).Conclusion The plaque characteristics correlate with the clinical presentation. The elevation of hs-CRP,proMMP-1 and

  16. Evaluating the intensity of the acoustic radiation force impulse (ARFI) in intravascular ultrasound (IVUS) imaging: Preliminary in vitro results.

    Science.gov (United States)

    Shih, Cho-Chiang; Lai, Ting-Yu; Huang, Chih-Chung

    2016-08-01

    The ability to measure the elastic properties of plaques and vessels is significant in clinical diagnosis, particularly for detecting a vulnerable plaque. A novel concept of combining intravascular ultrasound (IVUS) imaging and acoustic radiation force impulse (ARFI) imaging has recently been proposed. This method has potential in elastography for distinguishing between the stiffness of plaques and arterial vessel walls. However, the intensity of the acoustic radiation force requires calibration as a standard for the further development of an ARFI-IVUS imaging device that could be used in clinical applications. In this study, a dual-frequency transducer with 11MHz and 48MHz was used to measure the association between the biological tissue displacement and the applied acoustic radiation force. The output intensity of the acoustic radiation force generated by the pushing element ranged from 1.8 to 57.9mW/cm(2), as measured using a calibrated hydrophone. The results reveal that all of the acoustic intensities produced by the transducer in the experiments were within the limits specified by FDA regulations and could still displace the biological tissues. Furthermore, blood clots with different hematocrits, which have elastic properties similar to the lipid pool of plaques, with stiffness ranging from 0.5 to 1.9kPa could be displaced from 1 to 4μm, whereas the porcine arteries with stiffness ranging from 120 to 291kPa were displaced from 0.4 to 1.3μm when an acoustic intensity of 57.9mW/cm(2) was used. The in vitro ARFI images of the artery with a blood clot and artificial arteriosclerosis showed a clear distinction of the stiffness distributions of the vessel wall. All the results reveal that ARFI-IVUS imaging has the potential to distinguish the elastic properties of plaques and vessels. Moreover, the acoustic intensity used in ARFI imaging has been experimentally quantified. Although the size of this two-element transducer is unsuitable for IVUS imaging, the

  17. Volcanoes

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    In the past thousand years,volcanoes have claimed more than 300,000 lives. Volcanology is ayoung and dangerous science that helps us against the power of the Earth itself.We live on a fiery planet. Nearly 2000 miles beneath our feet, the Earth's inner core reachestemperatures of 12,000 degrees Fahrenheit. Molten rock or magma, rises to the earth's surface. Acold, rigid crust fractured into some twenty plates. When magma breaks through crust it becomes

  18. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Mæng, Michael; Thayssen, Per;

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects of the ...

  19. Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: Temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis A substudy of the ABSORB clinical trial

    NARCIS (Netherlands)

    H.M. Garcia-Garcia (Hector); N. Gonzalo (Nieves); R. Pawar (Ravindra); N. Kukreja (Neville); D. Dudek (Dariusz); L. Thuesen (Leif); J.A. Ormiston (John); E.S. Regar (Eveline); P.W.J.C. Serruys (Patrick)

    2009-01-01

    textabstractAims: The main objective was to use IVUS-backscatter radiofrequency (IVUS-RF) to assess the degradation of a bioabsorbable stent by measuring serial changes in dense calcium (DC) and necrotic core (NC) as assessed by intravascular ultrasound-Virtual Histology™ (IVUS-VH) and in the strain

  20. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon- expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial

    NARCIS (Netherlands)

    J.M.R. Ligthart (Jürgen); M-C. Morice (Marie-Claude); P.J. de Feyter (Pim); M. Degertekin (Muzaffer); K. Tanabe (Kengo); J.E. Sousa (Eduardo); A. Colombo (Antonio); G. Guagliumi (Giulio); W. Wijns (William); W.K. Lindeboom (Wietze); P.W.J.C. Serruys (Patrick); A.C. Abizaid (Alexandre)

    2002-01-01

    textabstractBACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238 patient

  1. Effect of Folic Acid Supplementation on Levels of Circulating Monocyte Chemoattractant Protein-1 and the Presence of Intravascular Ultrasound Derived Virtual Histology Thin-Cap Fibroatheromas in Patients with Stable Angina Pectoris

    NARCIS (Netherlands)

    K.H. Løland (Kjetil); O. Bleie (Oyvind); E. Strand (Elin); P.M. Ueland (Per); J. Nordrehaug (Jan); H.M. Garcia-Garcia (Hector); P.W.J.C. Serruys (Patrick); O. Nygård (Ottar)

    2013-01-01

    textabstractBackground:Virtual Histology Intravascular Ultrasound (VH-IVUS) may be used to detect early signs of unstable coronary artery disease. Monocyte Chemoattractant Protein-1 (MCP-1) is linked with coronary atherosclerosis and plaque instability and could potentially be modified by folic acid

  2. Comparison of neointimal morphology of in-stent restenosis with sirolimus-eluting stents versus bare metal stents: virtual histology-intravascular ultrasound analysis.

    Science.gov (United States)

    Yamamoto, Yoshihiro; Otani, Hajime; Iwasaka, Junji; Park, Haengnam; Sakuma, Takao; Kamihata, Hiroshi; Iwasaka, Toshiji

    2011-09-01

    Sirolimus-eluting stents (SES) have reduced the incidence of restenosis and target lesion revascularization compared to bare metal stents (BMS). However, inhibition of endothelialization and neointimal formation after SES implantation may produce vulnerable plaques. The present study compared the neointimal morphology of in-stent restenosis (ISR) between SES and BMS using virtual histology-intravascular ultrasound (VH-IVUS). Thirty ISR lesions (SES n = 15, BMS n = 15) demonstrated by coronary angiography in 30 patients with stable angina pectoris were analyzed with VH-IVUS between 6 months to 3 years after stent implantation. Tissue maps were reconstructed from radiofrequency data using VH-IVUS software. ISR lesions after SES implantation consisted of a significantly increased necrotic core (NC) compared to BMS (12.9 vs. 5.6% of neointimal volume, p stent thrombosis after SES implantation.

  3. Back-to-back optical coherence tomography-ultrasound probe for co-registered three-dimensional intravascular imaging with real-time display

    Science.gov (United States)

    Li, Jiawen; Ma, Teng; Jing, Joseph; Zhang, Jun; Patel, Pranav M.; Shung, K. Kirk; Zhou, Qifa; Chen, Zhongping

    2014-03-01

    We have developed a novel integrated optical coherence tomography (OCT)-intravascular ultrasound (IVUS) probe, with a 1.5 mm-long rigid-part and 0.9 mm outer diameter, for real-time intracoronary imaging of atherosclerotic plaques and guiding interventional procedures. By placing the OCT ball lens and IVUS 45MHz single element transducer back-to-back at the same axial position, this probe can provide automatically co-registered, co-axial OCT-IVUS imaging. To demonstrate its capability, 3D OCT-IVUS imaging of a pig's coronary artery in real-time displayed in polar coordinates, as well as images of two major types of advanced plaques in human cadaver coronary segments, was obtained using this probe and our upgraded system. Histology validation is also presented.

  4. Simultaneous occlusion of left anterior descending and left circumflex arteries by very late stent thrombosis: vascular response to drug-eluting stents assessed by intravascular ultrasound.

    Science.gov (United States)

    Yamawaki, Masahiro; Onuma, Yoshinobu; Nakano, Masatsugu; Muramatsu, Takashi; Nakatani, Shimpei; Ishibashi, Yuki; Ishimori, Hiroshi; Hirano, Keisuke; Ito, Yoshiaki; Tsukahara, Reiko; Muramatsu, Toshiya

    2015-11-01

    Very late stent thrombosis (VLST) is a catastrophic complication after implantation of a drug-eluting stent (DES). It has been reported that VLST is associated with pathological changes, which often include late acquired incomplete stent apposition (LAISA) with thrombus formation. In addition, the vascular response to the stent (evaginations, neointimal growth, and thrombosis) and the incidence of LAISA are reported to vary among the different types of DES. We experienced a patient with cardiogenic shock induced by simultaneous VLST of both the left anterior descending artery (LAD) and the left circumflex artery (LCX) at 3 years after implantation of two sirolimus-eluting stents. Intravascular ultrasound (IVUS) showed LAISA of both arteries. A paclitaxel-eluting stent, which had been implanted in the right coronary artery 3 years earlier, did not show such a finding. IVUS revealed "different vascular reactions" to "different types of DES" in this patient.

  5. Atherosclerotic plaque components characterization and macrophage infiltration identification by intravascular ultrasound elastography based on b-mode analysis: validation in vivo.

    Science.gov (United States)

    Zhang, Peng-Fei; Su, Hai-Jun; Zhang, Mei; Li, Ji-Fu; Liu, Chun-Xi; Ding, Shi-Fang; Miao, Ya; Chen, Liang; Li, Xiao-Nan; Yi, Xin; Zhang, Yun

    2011-01-01

    Intravascular ultrasound elastography (IVUSE) is a promising imaging technique for early investigation of vulnerable plaques. Compared to radiofrequency signal processing, digital B-mode analysis is simple and of higher portability. However, rare studies have been reported validating the latter technique in vivo. In this study, we developed an IVUSE computer software system involving semi-automatic border delineation and block-matching algorithm and validated the system in vivo. Seven minipigs were fed with atherogenic diet for 40 weeks. For each pig, the endothelium of one side of the renal arteries was denuded at the fifth week. With cross-correlation analysis, Lagrangian strain was calculated from two intravascular ultrasound images acquired in situ. Sixty regions of interests were selected from 35 elastograms matched well with the corresponding histological slices. Plaque types within these regions were classified as fibrous, fibro-fatty or fatty on Masson's trichrome and Oil-red O staining. Macrophage infiltration was also evaluated with immunohistology. Comparison between the mean strain value of the region of interest and the histological results revealed significant differences in strain values among different plaque types and non-diseased artery walls. The extent of macrophage infiltration was found to be correlated positively with strain values. For identification of fibro-fatty and fibrous plaques and macrophage infiltration, the system showed high sensitivity (93, 96 and 92%, respectively) and specificity (89, 76 and 66%, respectively), as revealed by receiver operating characteristic analysis. Our IVUSE system based on B-mode analysis is capable of characterizing fibrous and fibro-fatty plaques and macrophage intensity, thus holds potential for identifying vulnerable plaque.

  6. The qualitative assessment of biodegradable coronary stents with the use of intravascular ultrasound, optical coherence tomography and histology

    OpenAIRE

    Burcu GÜL

    2014-01-01

    Percutaneous coronary intervention (PCI) is the most common treatment for coronary artery disease (CAD). The first form of PCI introduced was balloon angioplasty. After that, the advent of coronary stents (tubular wire mesh for intravascular mechanical support) led to a new era in interventional cardiology. Through the implantation of bare metal stents (BMS), all three limitations of balloon angioplasty – coronary artery dissection, elastic recoil and negative remodelling – are prevented. Unf...

  7. Antiatherosclerotic effects of long-term maximally intensive statin therapy after acute coronary syndrome: insights from Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin.

    Science.gov (United States)

    Puri, Rishi; Nissen, Steven E; Shao, Mingyuan; Ballantyne, Christie M; Barter, Philip J; Chapman, M John; Erbel, Raimund; Libby, Peter; Raichlen, Joel S; Uno, Kiyoko; Kataoka, Yu; Nicholls, Stephen J

    2014-11-01

    Patients with acute coronary syndromes (ACS) display diffuse coronary atheroma instability and heightened risk of early and late recurrent coronary events. We compared the long-term antiatherosclerotic efficacy of high-intensity statins in patients with ACS when compared with stable disease. Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin (SATURN) used serial intravascular ultrasound measures of coronary atheroma volume in patients treated with rosuvastatin 40 mg or atorvastatin 80 mg for 24 months. The overall effect of high-intensity statins on the change in coronary percent atheroma volume and major adverse cardiovascular events (death/nonfatal myocardial infarction/coronary revascularization) were evaluated in this post hoc analysis. When compared with non-ACS patients (n=678), patients with ACS (n=361) were younger, actively smoking, and have had a previous myocardial infarction (all P<0.001). At baseline, patients with ACS exhibited lower high-density lipoprotein cholesterol (43.5±11 versus 45.8±11 mg/dL; P=0.002), a higher apolipoprotein B: apolipoprotein A-1 ratio (0.90±0.24 versus 0.83±0.24; P<0.001) and greater percent atheroma volume (37.3±8.5% versus 35.9±8.1%; P=0.01) when compared with non-ACS patients. Despite similar achieved levels of lipid and inflammatory markers after high-intensity statin therapy, patients with ACS demonstrated greater percent atheroma volume regression than non-ACS patients (-1.46±0.14 versus -0.89±0.13; P=0.003). After propensity-weighted multivariable adjustment, baseline percent atheroma volume (P<0.001) and an ACS clinical presentation (P=0.02) independently associated with plaque regression. The 24-month major adverse cardiovascular events-free survival was similar between patients with ACS and non-ACS (90.6 versus 92.9%; P=0.25). Long-term high-intensity statin therapy caused greater plaque regression and comparable major adverse cardiovascular events rates in

  8. Assessment of carotid plaque composition using fast-kV switching dual-energy CT with gemstone detector: comparison with extracorporeal and virtual histology-intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, Yuki; Kuya, Keita; Ohta, Yasutoshi; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Neurological Sciences, Faculty of Medicine, Yonago (Japan); Kishimoto, Junichi; Iwata, Naoki [Tottori University Hospital, Division of Clinical Radiology, Yonago (Japan)

    2015-09-15

    The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). Effective Z maps generated by GSI can detect vulnerable carotid plaque materials. (orig.)

  9. Evaluation of Variable Thin-Cap Fibroatheroma Definitions and Association of Virtual Histology-Intravascular Ultrasound Findings With Cavity Rupture Size.

    Science.gov (United States)

    Hirai, Taishi; Chen, Zhi; Zhang, Ling; Baaj, Shamsa; Kovarnik, Tomas; Porcaro, Katie; Kaminski, John; Hawn, Stephen; Agrawal, Anoop; Makki, Nader; Downe, Richard; Wahle, Andreas; Sonka, Milan; Lopez, John J

    2016-07-15

    The accepted definition of virtual histology intravascular ultrasound (IVUS-VH) thin-cap fibroatheroma (TCFA) is only a modest predictor of plaque rupture (PR). We sought to determine the relation between IVUS-VH findings and culprit lesions with PR using computational analysis. A total of 80 culprit lesions from 80 patients with stable angina (n = 37), unstable angina (n = 20), and myocardial infarction (n = 23) were divided into those with (n = 15) and without PR (n = 65). By use of automated computational analysis, the standard IVUS-VH TCFA criterion and 124 additional criteria were compared. The standard TCFA definition demonstrated modest ability to discriminate lesions with and without PR (sensitivity 87%, specificity 37%, PPV 0.24, and NPV 0.92). Of 124 additional IVUS-VH TCFA definitions, only 2 improved the discriminative ability even modestly. However, a positive correlation was demonstrated between cavity size and necrotic core percentage (r = 0.78, p VH criteria were only modestly associated with PR, without significant improvement by varying IVUS-VH TCFA features, but IVUS-VH features of ruptured plaques were strongly correlated with cavity size.

  10. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome. A comparative study with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Iriart, Xavier; Dos-Santos, Pierre [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Brunot, Sebastien [CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France); Coste, Pierre; Leroux, Lionel [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Montaudon, Michel [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Labeque, Jean-Noel; Jais, Catherine [Unite de Soins Intensifs Cardiologiques, Pessac (France); Laurent, Francois [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France)

    2007-10-15

    We compared 16-slice computed tomography (CT) with intravascular ultrasound (IVUS) in their ability to identify the culprit lesion, and to assess plaque characterization and vascular remodelling in acute coronary syndrome (ACS). Twenty patients were prospectively studied. Coronary plaque identification and characterization were compared using 16-slice CT and 40-MHz catheter-based IVUS. Minimum lumen area (MLA), cross-sectional vessel area (CVA) and vessel remodelling were determined for each comparable lesion. One hundred and sixty-nine segments were compared and 84 plaques analysed. Sixteen-slice CT detected 95% of culprit lesions (19/20). No feature suggestive of plaque rupture was detected by 16-slice CT. Attenuation measurements within all lesions revealed different values for hypoechoic (38 {+-} 33 HU), hyperechoic (94 {+-} 44 HU), and calcified plaques (561 {+-} 216 HU), (P < 0.001). Agreement between 16-slice CT and IVUS on measuring MLA and CVA was evaluated using Bland-Altman analysis. Pearson and intra-class coefficient (ICC) were 0.81 and 0.70 for MLA, and 0.81 and 0.36 for CVA, for 16-slice CT and IVUS, respectively. Agreement between both techniques for vessel positive remodelling was moderate (kappa = 0.54, P < 0.001). Sixteen-slice CT has shown moderate accuracy in quantifying and characterizing coronary plaques compared with IVUS. Spatial resolution of 16-slice CT remains a major limitation, however, to accurately assess the complex lesions involved in ACS. (orig.)

  11. Enhanced characterization of calcified areas in intravascular ultrasound virtual histology images by quantification of the acoustic shadow: validation against computed tomography coronary angiography.

    Science.gov (United States)

    Broersen, Alexander; de Graaf, Michiel A; Eggermont, Jeroen; Wolterbeek, Ron; Kitslaar, Pieter H; Dijkstra, Jouke; Bax, Jeroen J; Reiber, Johan H C; Scholte, Arthur J

    2016-04-01

    We enhance intravascular ultrasound virtual histology (VH) tissue characterization by fully automatic quantification of the acoustic shadow behind calcified plaque. VH is unable to characterize atherosclerosis located behind calcifications. In this study, the quantified acoustic shadows are considered calcified to approximate the real dense calcium (DC) plaque volume. In total, 57 patients with 108 coronary lesions were included. A novel post-processing step is applied on the VH images to quantify the acoustic shadow and enhance the VH results. The VH and enhanced VH results are compared to quantitative computed tomography angiography (QTA) plaque characterization as reference standard. The correlation of the plaque types between enhanced VH and QTA differs significantly from the correlation with unenhanced VH. For DC, the correlation improved from 0.733 to 0.818. Instead of an underestimation of DC in VH with a bias of 8.5 mm(3), there was a smaller overestimation of 1.1 mm(3) in the enhanced VH. Although tissue characterization within the acoustic shadow in VH is difficult, the novel algorithm improved the DC tissue characterization. This algorithm contributes to accurate assessment of calcium on VH and could be applied in clinical studies.

  12. Ultrasound transducer assembly and method for manufacturing an ultrasound transducer assembly

    NARCIS (Netherlands)

    Dekker, R.; Henneken, V.A.; Louwerse, M.C.; Raganato, M.F.

    2015-01-01

    The present invention relates to an ultrasound transducer assembly (10), in particular for intravascular ultrasound systems. The ultrasound transducer assembly comprises at least one silicon substrate element (30) including an ultrasound transducer element (14) for emitting and receiving ultrasound

  13. Ultrasound transducer assembly and method for manufacturing an ultrasound transducer assembly

    NARCIS (Netherlands)

    Dekker, R.; Henneken, V.A.; Louwerse, M.C.; Raganato, M.F.

    2015-01-01

    The present invention relates to an ultrasound transducer assembly (10), in particular for intravascular ultrasound systems. The ultrasound transducer assembly comprises at least one silicon substrate element (30) including an ultrasound transducer element (14) for emitting and receiving ultrasound

  14. Automated Retrieval of Key Frames from Intravascular Ultrasound Image Sequences%血管内超声图像序列关键帧的自动检索

    Institute of Scientific and Technical Information of China (English)

    王立欣; 孙正

    2015-01-01

    Manual retrieval of key frames from an Intravascular Ultrasound (IVUS) pullback sequence is a tedious and time-consuming task. The retrieval results are subjective and highly depend on clinical experiences and professional knowledge of the operator. In this paper, two methods for automatically retrieving key frames in an IVUS image sequence are proposed. One is based on the description of the vascular morphology. First, the morphological profiles of vessel are extracted. Then, the sequences of cross-sectional areas in each frame are coded with the symbolic aggregate approximation (SAX) algorithm. Finally, key frames are selected through comparing the Euclidean distances between the coded area sequences of successive frames with a properly selected threshold. The other is based on the histograms of IVUS images. The key frames are retrieved through comparing the Bhattacharyya distances between histograms of successive frames with a properly selected threshold. The validity of both methods has been validated in vivo image data and the accuracy was quantitatively evaluated. The results show that a higher compression ratio, lower redundancy and higher precision can be obtained with the morphological description method than the histogram method. However, its efficiency is relatively lower than the histogram method.%针对临床采集的血管内超声(Intravascular Ultrasound, IVUS)图像序列数据量巨大,由人工逐帧检查和分析非常繁琐且客观性差的问题,本文提出两种自动检索IVUS图像序列中关键帧的方法.其一是基于血管形态的方法:首先提取图像中的血管壁轮廓,并使用符号聚集近似(SAX)算法对轮廓包围区域的面积序列进行量化编码,进而计算出相邻两帧的血管横截面积序列之间的欧氏距离,提取出关键帧;其二是基于图像灰度直方图的方法,即通过计算图像灰度直方图之间的巴氏距离提取关键帧.利用临床采集的图像数据分别验证了两

  15. Value of intravascular ultrasound imaging in following up patients with replacement of the ascending aorta for acute type A aortic dissection

    Institute of Scientific and Technical Information of China (English)

    HU Wei; Francois Schiele; Nicolas Meneveau; Made-France Seronde; Pierre Legalery; Fiona Caulfield; Jean-Francois Bonneville; Sidney Chocron; Jean-Pierre Bassand

    2008-01-01

    Background The value of intravascular ultrasound (IVUS) imaging in patients with replacement of the ascending aorta for acute type A aortic dissection (AD) is unknown.The purpose of this study was to assess the potential use of IVUS imaging in this setting.Methods From September 2002 to July 2005,IVUS imaging with a 9 MHz probe was performed in a series of 16 consecutive patients with suspected or established AD.This study focused on 5 of them with replacement of the ascending aorta for acute type A AD.Among these 5 patients,other imaging modalities including aortography,spiral computed tomography,magnetic resonance imaging and transesophageal echocardiography were performed in 5,3,3 and 1 patients,respectively.Results There were no complications related to IVUS imaging.For the replaced graft,as other imaging modalities,IVUS could identify all 5 grafts,the proximal and the distal anastomoses,and the ostia of the reimplanted coronary arteries.In 2 cases,IVUS detected 2 peri-graft pseudo-aneurysms (1 per case),which were also detected by magnetic resonance imaging but omitted by aortography.For the residual dissection,IVUS had similar findings as other imaging modalities in detecting the patency (5/5),the longitudinal and the circumferential extent,the thrombus (4/5),the recurrent dissection (1/5) and an aneurysm distal to the graft (5 in 4 patients).However,it detected more intimal tears and side branch involvements than other imaging modalities (15 vs 10 and 3 vs 1,respectively).Conclusions In following-up patients with replacement of the ascending aorta for acute type A AD,IVUS imaging can provide complete information of the replaced graft and the residual dissection.So,IVUS imaging may be considered when the four current frequently used imaging modalities can not supply sufficient information or there are some discrepancies between them.

  16. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    Science.gov (United States)

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS.

  17. Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Lodi-Junqueira Lucas

    2012-09-01

    Full Text Available Abstract Background The role of intravascular ultrasound (IVUS in percutaneous coronary interventions (PCI is still controversial despite several previously published meta-analyses. A meta-analysis to evaluate the controversial role of IVUS-guided PCI with bare-metal stenting was performed and a previous published meta-analysis was re-evaluated in order to clarify the discrepancy between results of these studies. Methods A systematic review was performed by an electronic search of the PubMed, Embase and Web of Knowledge databases and by a manual search of reference lists for randomized controlled trials published until April 2011, with clinical outcomes and, at least, six months of clinical follow-up. A meta-analysis based on the intention to treat was performed with the selected studies. Results Five studies and 1,754 patients were included. There were no differences in death (OR = 1.86; 95% CI = 0.88-3.95; p = 0.10, non-fatal myocardial infarction (OR = 0.65; 95% CI = 0.27-1.58; p = 0.35 and major adverse cardiac events (OR = 0.74; 95% CI = 0.49-1.13; p = 0.16. An analysis of the previous published meta-analysis strongly suggested the presence of publication bias. Conclusions There is no evidence to recommend routine IVUS-guided PCI with bare-metal stent implantation. This may be explained by the paucity and heterogeneity of the studies published so far.

  18. Comparison of two- and three-dimensional quantitative coronary angiography to intravascular ultrasound in the assessment of intermediate left main stenosis.

    Science.gov (United States)

    Porto, Italo; Dato, Ilaria; Todaro, Daniel; Calabrese, Michele; Rigattieri, Stefano; Leone, Antonio Maria; Niccoli, Giampaolo; Burzotta, Francesco; Trani, Carlo; Crea, Filippo

    2012-06-01

    Angiographic evaluation of intermediate left main coronary artery stenosis (LMS) is often limited. Three-dimensional (3D) quantitative coronary angiography has recently developed to overcome 2-dimensional (2D) quantitative coronary angiographic (QCA) limitations. In patients with angiographically intermediate LMS, we investigated whether 3D quantitative coronary angiography was superior to 2D quantitative coronary angiography in predicting the presence of a significant LMS, defined as a minimum luminal area <6 mm(2) at intravascular ultrasound (IVUS). 2D and 3D quantitative coronary angiography were compared in their measurements of minimum luminal area, percent area stenosis, minimum luminal diameter, and percent diameter stenosis and in their prediction of an IVUS minimum luminal area <6 mm(2). In total 58 target lesions were interrogated, 25 (43%) of which had an IVUS minimum luminal area <6 mm(2). Correlation between 3D-QCA minimum luminal area and IVUS minimum luminal area was stronger than the correlation between 2D-QCA minimum luminal area (or minimum luminal diameter) and IVUS minimum luminal area (R = 0.67, p = 0.0001, and R = 0.40, p = 0.001, respectively, p = 0.04 for comparison). To predict IVUS minimum luminal area <6 mm(2), the most accurate 2D-QCA measurement was minimum luminal diameter (area under curve 0.81, cutoff 2.2 mm, p = 0.0001), and the most accurate 3D-QCA measurement was minimum luminal area (area under curve 0.86, cutoff 5.6 mm(2), p = 0.0001). 2D-QCA percent diameter stenosis did not significantly predict IVUS minimum luminal area <6 mm(2) (area under curve 0.56, cutoff 38%, p = 0.45). In conclusion, the accuracy of quantitative coronary angiography in predicting LM IVUS minimum luminal area <6 mm(2) is limited. When IVUS is not available or contraindicated, 3D quantitative coronary angiography may assist in the evaluation of intermediate LMS. Among 2D-QCA parameters, minimum luminal diameter is more accurate than percent diameter

  19. Different edge effects of paclitaxel-and sirolimus-eluting stents on proximal and distal edges in patients with unstable angina:serial intravascular ultrasound analysis

    Institute of Scientific and Technical Information of China (English)

    CHEN Shao-liang; YE Fei; ZHANG Jun-jie; LIU Zhi-zhong; SHAN Shou-jie; SUN Xue-wen; ZHANG Ai-ping; CHEN Jing-guo; XU Ya-wei; YANG Song; CHEN Feng; LUO Weng-ping

    2009-01-01

    Background It is unclear whether edge segments have different responses to paclitaxel eluting stent (PES) and sirolimus eluting stent (SES) implantation in patients with unstable angina. This study aimed to compare the different vascular edge responses in patients with unstable angina and single de novo coronary lesion treated with SES and PES. Methods Two hundred and fifty-five patients with unstable angina and single de novo lesion were randomly assigned to PES and SES groups. Serial volumetric intravascular ultrasound (IVUS) images were taken immediately after stenting and at an eight-month follow-up. Five-mm edge segments proximal and distal to the stents were analyzed. Results Baseline characteristics were comparable between the two groups. At proximal-edge segment, the vessel area decreased and the plaque area increased significantly in the PES group as compared with the SES group. A significant net loss of lumen area was found in the PES group (from (11.10±3.12) mm2 at baseline to (9.92+3.59) mm2 at the follow-up, P <0.001). At the distal-edge segment, the net loss of lumen area in the PES group (from (7.71±2.81) mm2 at baseline to (6.66±2.29) mm2 at the follow-up, P <0.001) was attributed to a significant increase of plaque area. Proximal-edge stenosis was commonly seen in the PES group (20.0%) as compared with the SES group (5.0%, P=0.001). This correlated with the higher incidence of target lesion revascularization in the PES group (P=-0.03). Subsegmentally, the smallest A lumen area was located at 2 mm proximally in both groups, at 0 mm distally in the PES group, and at 1 mm distally in the SES group. Conclusions The two groups demonstrated negative remodeling of edge segments. PES was less effective than SES in inhibiting the growth of plaque within the first 1-mm length proximal to the stent.

  20. PCA-based polling strategy in machine learning framework for coronary artery disease risk assessment in intravascular ultrasound: A link between carotid and coronary grayscale plaque morphology.

    Science.gov (United States)

    Araki, Tadashi; Ikeda, Nobutaka; Shukla, Devarshi; Jain, Pankaj K; Londhe, Narendra D; Shrivastava, Vimal K; Banchhor, Sumit K; Saba, Luca; Nicolaides, Andrew; Shafique, Shoaib; Laird, John R; Suri, Jasjit S

    2016-05-01

    Percutaneous coronary interventional procedures need advance planning prior to stenting or an endarterectomy. Cardiologists use intravascular ultrasound (IVUS) for screening, risk assessment and stratification of coronary artery disease (CAD). We hypothesize that plaque components are vulnerable to rupture due to plaque progression. Currently, there are no standard grayscale IVUS tools for risk assessment of plaque rupture. This paper presents a novel strategy for risk stratification based on plaque morphology embedded with principal component analysis (PCA) for plaque feature dimensionality reduction and dominant feature selection technique. The risk assessment utilizes 56 grayscale coronary features in a machine learning framework while linking information from carotid and coronary plaque burdens due to their common genetic makeup. This system consists of a machine learning paradigm which uses a support vector machine (SVM) combined with PCA for optimal and dominant coronary artery morphological feature extraction. Carotid artery proven intima-media thickness (cIMT) biomarker is adapted as a gold standard during the training phase of the machine learning system. For the performance evaluation, K-fold cross validation protocol is adapted with 20 trials per fold. For choosing the dominant features out of the 56 grayscale features, a polling strategy of PCA is adapted where the original value of the features is unaltered. Different protocols are designed for establishing the stability and reliability criteria of the coronary risk assessment system (cRAS). Using the PCA-based machine learning paradigm and cross-validation protocol, a classification accuracy of 98.43% (AUC 0.98) with K=10 folds using an SVM radial basis function (RBF) kernel was achieved. A reliability index of 97.32% and machine learning stability criteria of 5% were met for the cRAS. This is the first Computer aided design (CADx) system of its kind that is able to demonstrate the ability of coronary

  1. Long-term effects of biodegradable versus durable polymer-coated sirolimus-eluting stents on coronary arterial wall morphology assessed by virtual histology intravascular ultrasound

    Institute of Scientific and Technical Information of China (English)

    LIU Hui-liang; ZHANG Jiao; JIN Zhi-geng; LUO Jian-ping; MA Dong-xing; YANG Sheng-li; LIU Ying; HAN Wei; JING Li-min; MENG Rong-ying

    2011-01-01

    Background The durable presence of polymer coating on drug-eluting stent (DES) surface may be one of the principal reasons for stent thrombosis. The long-term coronary arterial response to biodegradable polymer-coated sirolimus-eluting stent (BSES) in vivo remained unclear.Methods Forty-one patients were enrolled in this study and virtual histology intravascular ultrasound (VH-IVUS) was performed to assess the native artery vascular responses to BSES compared with durable polymer-coated SES (DSES) during long-term follow-up (median: 8 months). The incidence of necrotic core abutting to the lumen was evaluated at follow-up.Results With similar in-stent late luminal loss (0.15 mm (0.06-0.30 mm) vs. 0.19 mm (0.03-0.30 mm), P=0.772), the overall incidence of necrotic core abutting to the lumen was significantly less in BSES group than in DSES group (44% vs.63%, P <0.05) (proximal 18%, stented site 14% and distal 12% in BSES group, proximal 19%, stented site 28% and distal 16% in DSES group). The DSES-treated segments had a significant higher incidence of necrotic core abutting to the lumen through the stent struts (73% vs. 36%, P <0.01). In addition, more multiple necrotic core abutting to the lumen was observed in DSES group (overall: 63% vs. 36%, P <0.05). Furthermore, when the stented segments with necrotic core abutting to the lumen had been taken into account only, DSES-treated lesions tended to contain more multiple necrotic core abutting to the lumen through the stent struts than BSES-treated lesions (74% vs. 33%), although there was no statistically significant difference between them (P=0.06).Conclusions By VH-IVUS analysis at follow-up, a greater frequency of stable lesion morphometry was shown in lesions treated with BSESs compared with lesions treated with DSESs. The major reason was BSES produced less toxicity to the arterial wall and facilitated neointimal healing as a result of polymer coating on DES surface biodegraded as time went by.

  2. 心肌梗死相关冠状动脉的腔内超声研究%Intravascular ultrasound study of arteries related myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    陈绍良; 徐玲; 段宝祥; 常芸; 刘玲玲

    2000-01-01

    Objective To characterize the lesion in acute myocardial infarction(AMI)-related artery (IRA)by the intravascular ultrasound(IVUS)and angiography image at the culprit site. Methods twenty-five patients with AMI undenwent IVUS study of the IRA immediately following PTCA to the culprit lesion. The IVUS images were analyzed quantitatively and qualitatively and were compared with the angiography. Results ①At the PTCA site, mean area was narrowed down 50%-70% and mean cross-sectional area(CSA) of the plaque was(50±18)% of the arterial CSA;②The atherosclerosis was found in 70% of the proximal and distal segments by IVUS and 30% of these segments by the angiogram(P=0.001);③All the plaques were defined as 69% "Soft" and 31% "hard".The hard plaques were larger than the soft plaques [(50±16)% VS (37±19)% CSA.P=0.01]:④With the increase in plaque area there was a significant increase in arterial ross-sectional area in an the injured segments(r=0.49,P=0.003)as well as in distal and proximal control segments to culprit site.Conclusion IVUS revealed a significant plaque burden at the culprit lesion Of IRA and atherosclerosis in the proximal and distal control segments to the lesion.%目的 比较心肌梗死相关冠状动脉造影和血管内超声下粥样斑块的特征.方法 25例急性心肌梗死患者的梗死相关动脉(IRA)在成功经皮冠状动脉腔内成形术(PTCA)后即刻行冠状动脉内超声检查,结果与冠状动脉造影进行定量和定性比较.结果 ①在PTCA部位,平均面积狭窄50%-70%,斑块横截面积是血管横截面积的(50±18)%;②冠状动脉内超声下病变的近端和远端粥样硬化发生率为70%,而冠状动脉造影下上述部位的病变率仅30%(P=0.001);③69%斑块属于软斑块,硬斑块占31%,但是其斑块面积却大于前者[(50±16)% vs (39±19)%,P=0.01;④PTCA部位所有近端与远端参考段血管腔内斑块面积与血管横截面积之间相关良好(r-0.49,P=0.0001),病变段血管

  3. Neointimal hyperplasia after sirolimus-eluting and paclitaxel-eluting stent implantation in diabetic patients: the Randomized Diabetes and Drug-Eluting Stent (DiabeDES) Intravascular Ultrasound Trial

    DEFF Research Database (Denmark)

    Jensen, L.O.; Maeng, M.; Thayssen, P.;

    2008-01-01

    AIMS: Patients with diabetes have increased risk of in-stent restenosis after coronary stent implantation owing to neointimal hyperplasia (NIH). The aim of the study was to evaluate the extent and distribution of NIH with intravascular ultrasound (IVUS) after coronary artery stenting with sirolimus......-eluting (Cypher) or paclitaxel-eluting (Taxus) stents in diabetic patients. METHODS AND RESULTS: One hundred and thirty diabetic patients were randomized to Cypher or Taxus stent implantation. IVUS was performed at 8 month follow-up. NIH volume was significantly reduced in the Cypher group when compared...... with the Taxus group: median (inter-quartile range) 0.0 (0.0-0.0) vs. 8.0 mm(3) (0.1-33.0), P stents compared with Taxus stents: median (inter-quartile range) 0.0 (0.0-0.0) vs. 7.5% (0.1-27.0), P stent...

  4. Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients the randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Maeng, Michael; Thayssen, Per;

    2013-01-01

    OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients. BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent...... implantation due to intimal hyperplasia (IH). METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available...... in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0...

  5. Ultrasound

    Science.gov (United States)

    Ultrasound is a type of imaging. It uses high-frequency sound waves to look at organs and ... liver, and other organs. During pregnancy, doctors use ultrasound to view the fetus. Unlike x-rays, ultrasound ...

  6. 血管内超声测量血流动力学参数的研究进展%Progresses of intravascular ultrasound in measurement of hemodynamic parameters

    Institute of Scientific and Technical Information of China (English)

    孙正

    2013-01-01

    Intravascular ultrasound (IVUS) can record the morphology of vessel wall,lumen and plaque,composition of plaques and even wall functional features in vivo.Detecting hemodynamic parameters of coronary arteries,including elastic modulus of vessel wall and wall shear stress and strain,etc.,from intracoronary ultrasound images is important for diagnosing coronary heart diseases and planning the treatment.The progresses of quantitative measurement of hemodynamic parameters of coronary arteries from IVUS images were reviewed in this article.%血管内超声显像可在活体中观察血管壁、管腔及斑块形态、性质,甚至斑块成分和管壁功能状态,由此获得的冠状动脉的血流动力学参数(包括管壁的弹性模量和血管壁应力-应变分布等)对于正确诊断冠心病、制定最佳诊疗方案具有重要意义.本文就近年来血管内超声在冠状动脉血流动力学参数测量中的应用进行综述.

  7. Denoising and enhancement in intravascular ultrasound images via multiscale analysis%基于多尺度分析的血管内超声图像去噪和增强

    Institute of Scientific and Technical Information of China (English)

    李虹; 王惠南; 章哓国

    2008-01-01

    提出基于二进小波变换的血管内超声图像血液斑点噪声抑制和对比度增强算法.血液红细胞散射引起的斑点噪声属于乘性噪声,在对数域进行二进小波变换后,结合软阈值滤波法和硬阈值滤波法对不同尺度的小波系数进行萎缩处理,并提出了一种局部阈值估计方法.同时采用了基于多尺度边缘表示的,利用小波系数极值拉伸和Hermite多项式插值实现的快速增强算法.实验结果表明,与现有单独进行去噪处理的方法相比,该方法在抑制血液斑点噪声的同时增强了图像对比度,具有更好的实用性.%An algorithm based on dyadic wavelet transform for speckle reduction and contrast enhancement in intravascular ultrasound images was presented. Wavelet shrinkage techniques which combined soft and hard thresholding were applied to coefficients of logarithmically transformed images since scattering from red blood cells (blood speckle noise) was multiplicative noise and a method to estimate local threshold was proposed. In addition, a fast contrast enhancement algorithm based on multi-scale edges representation of images through stretching the local extrema and interpolating them with Hermite interpolation polynomials was carried out. Experiments with clinical images showed that this algorithm was capable of not only reducing the speckle noise of blood but also enhancing features of diagnostic importance of intravascular ultrasound images and produced superior results qualitatively when compared to results obtained from existing denoising methods alone.

  8. A Novel Model of Atherosclerosis in Rabbits Using Injury to Arterial Walls Induced by Ferric Chloride as Evaluated by Optical Coherence Tomography as well as Intravascular Ultrasound and Histology

    Directory of Open Access Journals (Sweden)

    Jinwei Tian

    2012-01-01

    Full Text Available This study aim was to develop a new model of atherosclerosis by FeCl3-induced injury to right common carotid arteries (CCAs of rabbits. Right CCAs were induced in male New Zealand White rabbits (=15 by combination of a cholesterol-rich diet and FeCl3-induced injury to arterial walls. The right and left CCAs were evaluated by histology and in vivo intravascular ultrasound (IVUS and optical coherence tomography (OCT examinations of 24 hours (=3, 8 weeks (=6, and 12 weeks (=6 after injury. Each right CCA of the rabbits showed extensive white-yellow plaques. At eight and 12 weeks after injury, IVUS, OCT, and histological findings demonstrated that the right CCAs had evident eccentric plaques. Six plaques (50% with evident positive remodeling were observed. Marked progression was clearly observed in the same plaque at 12 weeks after injury when it underwent repeat OCT and IVUS. We demonstrated, for the first time, a novel model of atherosclerosis induced by FeCl3. The model is simple, fast, inexpensive, and reproducible and has a high success rate. The eccentric plaques and remodeling of plaques were common in this model. We successfully carried out IVUS and OCT examinations twice in the same lesion within a relatively long period of time.

  9. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S;

    2009-01-01

    Scientific, Maple Grove, Minnesota) stents in diabetic patients. Seventy-four diabetic patients were randomly assigned to Cypher or Taxus stent implantation. Intravascular ultrasound of 5-mm long segments immediately proximal and distal to the stent was performed after the procedure and at the 8-month follow.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2......); p = 0.097; proximal, 8.1 +/- 2.7 to 8.7 +/- 2.9 mm(2); p = 0.006) without remodeling (change in EEM) in the Taxus group. Conversely, there were no significant changes in reference-segment EEM or plaque areas in the Cypher group. In conclusion, in diabetic patients, Taxus stent implantation...

  10. Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.

    Science.gov (United States)

    Mariani, José; Guedes, Cristiano; Soares, Paulo; Zalc, Silvio; Campos, Carlos M; Lopes, Augusto C; Spadaro, André G; Perin, Marco A; Filho, Antonio Esteves; Takimura, Celso K; Ribeiro, Expedito; Kalil-Filho, Roberto; Edelman, Elazer R; Serruys, Patrick W; Lemos, Pedro A

    2014-11-01

    The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI). To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast. A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months. The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p MOZART]; NCT01947335). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Disseminated intravascular coagulation (DIC)

    Science.gov (United States)

    ... Jr, Silberstein LE, et al, eds. Hematology: Basic Principles and Practice . 6th ed. Philadelphia, PA: Elsevier Saunders; 2013:chap 141. Thachil J, Toh CH. Current concepts in the management of disseminated intravascular coagulation. Thromb Res . 2012;129 ...

  12. Intravascular malignant lymphomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Duverneuil, N.; Lafitte, F.; Chiras, J. [Service de Neuroradiologie Charcot, Batiment Babinski, Hopital de la Salpetriere, 75013 Paris (France); Mokhtari, K. [Service de Neuropathologie, Hopital de la Salpetriere, 75013 Paris (France); Behin, A.; Hoang-Xuan, K. [Departement de Neurologie, Hopital de la Salpetriere, 75013 Paris (France)

    2002-09-01

    Intravascular malignant lymphomatosis is a rare and probably often overlooked disease characterised by massive intravascular proliferation of lymphoid cells, usually with a poor prognosis. CT and MRI appearances are nonspecific; the most suggestive finding being both asymmetrical, bilateral, contrast enhancing high-signal areas on T2 weighting and infarct-like lesions of the cortex and basal ganglia. We report two patients with previously unreported dural and spinal cord involvement. (orig.)

  13. Three Dimensional Segmentation of Intravascular Ultrasound Image Sequence Based on Fast Marching%基于快速推进法的血管内超声图像序列的三维分割

    Institute of Scientific and Technical Information of China (English)

    杨宇

    2011-01-01

    目的 血管内超声(intravascular ultrasound,IVUS)是近年来临床诊断血管病变的一项新技术.对IVUS图像进行分割,提取出图像中血管壁的内膜和中-外膜轮廓,是IVUS图像序列定量分析和三维重建的重要步骤.方法 本文提出一种基于快速推进法的IVUS图像序列三维并行分割方法.在完成对原始图像的滤波去噪、抑制导管伪影等预处理后,获取IVUS序列纵向视图,并从中提取出血管壁的内膜和中 -外膜轮廓,然后将该轮廓映射到每帧IVUS横向视图中,得到各IVUS帧中血管壁的内膜和中-外膜轮廓,最后采用快速推进法对初始轮廓进行演化变形,最终提取出目标轮廓.结果 对临床IVUS图像数据进行实验,与逐帧处理的串行分割方法相比,本文方法明显提高了处理效率,克服了传统串行处理方法运算效率低的缺点.结论 该方法对血管疾病的临床诊治具有重要意义.%Objective Intravascular ultrasound (IV US) is used in clinical diagnosis of vascular disease as a new technology in recent years. The detection of vascular wall from IV US image to get the intima contour and the media - adventitia contour of vessel wall is an important step in quantitative analysis and three -dimensional reconstruction of IVUS image sequence. Methods We proposed a three dimensional parallel segmentation of IVUS image sequence based on fast marching method. After the pretreatments of original images, such as filtering, smoothing and suppression of ring - down artifacts, IVUS longitudinal cut was obtained and its detected vessel wall contours were mapped into each cross - sectional slice to obtain initial vessel wall contours in each IVUS frame. Finally, with the fast marching algorithm, initial contours deformed until stopping at the actual contours. Results The data of the experiment on clinical IV US image showed that this method greatly improved the efficiency and overcame the shortcomings of the traditional

  14. Ultrasound

    Science.gov (United States)

    ... Saunders; 2014:chap 66. Cosgrove DO, Eckersley RJ, Harvey CJ, Lim A. Ultrasound. In: Adam A, Dixon AK, Gillard ... Northside Radiology Associates, Atlanta, GA. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the ...

  15. Angiographic and clinical comparisons of intravascular ultrasound- versus angiography-guided drug-eluting stent implantation for patients with chronic total occlusion lesions: two-year results from a randomised AIR-CTO study.

    Science.gov (United States)

    Tian, Nai-Liang; Gami, Sandeep-Kumar; Ye, Fei; Zhang, Jun-Jie; Liu, Zhi-Zhong; Lin, Song; Ge, Zhen; Shan, Shou-Jie; You, Wei; Chen, Liang; Zhang, Yao-Jun; Mintz, Gary; Chen, Shao-Liang

    2015-04-01

    This study sought to compare angiographic endpoints at one-year follow-up after a drug-eluting stent implantation guided by either intravascular ultrasound (IVUS) or angiography in patients with chronic total occlusion (CTO) lesions. Patients with at least one CTO lesion recanalised successfully were randomly assigned to the IVUS-guided or the angiography-guided group. The use of IVUS for penetration of the true lumen and optimisation of stent expansion was only done in the IVUS-guided group. The primary endpoint was in-stent late lumen loss (LLL) at one-year follow-up. A total of 230 patients with CTO lesions after successful recanalisation were enrolled and followed with office visits or telephone contact up to 24 months. In-stent LLL in the IVUS-guided group was significantly lower compared to the angiography-guided group at one-year follow-up (0.28±0.48 mm vs. 0.46±0.68 mm, p=0.025), with a significant difference in restenosis of the "in-true-lumen" stent between the two groups (3.9% vs.13.7%, p=0.021). The minimal lumen diameter and minimal stent cross-section area significantly and negatively correlated with LLL (all pCTO lesion was associated with less LLL and a lower incidence of "in-true-lumen" stent restenosis. Additional study is required to identify the clinical benefit of the IVUS-guided procedure for CTO lesions. [ChiCTR-TRC-10000996].

  16. Brachytherapy optimal planning with application to intravascular radiation therapy

    DEFF Research Database (Denmark)

    Sadegh, Payman; Mourtada, Firas A.; Taylor, Russell H.;

    1999-01-01

    . Dose rate calculations are based on the sosimetry formulation of the American Association of Physicists in Medicine, Task Group 43. We apply the technique to optimal planning for intravascular brachytherapy of intimal hyperplasia using ultrasound data and 192Ir seeds. The planning includes...

  17. Intravascular lymphoma mimicking vasculitis.

    Science.gov (United States)

    Prayson, Richard A

    2016-12-01

    Intravascular lymphoma is a rare malignancy which is characterized by a proliferation of atypical appearing B cells, generally confined to vascular lumina. A tissue biopsy demonstrating the pathology is required to make a diagnosis. The tumor is often disseminated at the time of diagnosis and prognosis is poor, even with aggressive chemotherapy. Neurologic presentations of this neoplasm can be quite varied. This report documents the presence of intravascular lymphoma diagnosed on a brain biopsy in a 60-year-old man. He initially presented 6months before brain biopsy with chest pain and hypotension, warranting coronary artery bypass graft surgery. Four months later, he presented with signs attributed to a stroke (diaphoresis, slumped over in a chair and left hand weakness). He subsequently developed a sudden onset wide-based gait, left leg numbness, word finding difficulties and worsening confusion. A MRI study showed multiple infarcts in the brain, including cerebellum. Invasive angiogram suggested vasculitis. He was started on a course of treatment for presumed central nervous system vasculitis. He continued to develop signs suggestive of ongoing infarct development and a biopsy from the right parietal was taken. The biopsy showed atypical intravascular CD20 positive staining B cells, consistent with intravascular lymphoma. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Effect of folic acid supplementation on levels of circulating Monocyte Chemoattractant Protein-1 and the presence of intravascular ultrasound derived virtual histology thin-cap fibroatheromas in patients with stable angina pectoris.

    Directory of Open Access Journals (Sweden)

    Kjetil H Løland

    Full Text Available BACKGROUND: Virtual Histology Intravascular Ultrasound (VH-IVUS may be used to detect early signs of unstable coronary artery disease. Monocyte Chemoattractant Protein-1 (MCP-1 is linked with coronary atherosclerosis and plaque instability and could potentially be modified by folic acid treatment. METHODS: In a randomized, prospective study, 102 patients with stable angina pectoris (SAP received percutaneous coronary intervention and established medical treatment as well as either homocysteine-lowering folic acid/vitamin B12 (± B6 or placebo (± B6 for 1 year before VH-IVUS was performed. The presence of VH-Thin-Cap Fibroatheroma (VH-TCFA in non-intervened coronary vessels was registered and serum levels of MCP-1 were measured. The patients were subsequently followed for incident myocardial infarction (MI. RESULTS: Patients treated with folic acid/vitamin B12 had a geometric mean (SD MCP-1 level of 79.95 (1.49 versus 86.00 (1.43 pg/mL for patients receiving placebo (p-value 0.34. VH-TCFA lesions were present in 7.8% of patients and did not differ between intervention arms (p-value 0.47. Serum levels of MCP-1 were 1.46 (95% CI 1.12 to 1.92 times higher in patients with VH-TCFA lesions than in those without (p-value 0.005. Afterwards, patients were followed for median 2.1 years and 3.8% experienced a myocardial infarction (MI, which in post-hoc Cox regression analyses was independently predicted by both MCP-1 (P-value 0.006 and VH-TCFA (p-value 0.01. CONCLUSIONS: In patients with SAP receiving established medical treatment, folic acid supplementation is not associated with either presence of VH-TCFA or levels of MCP-1. MCP-1 is however associated with VH-TCFA, a finding corroborated by increased risk for future MI. ClinicalTrials.gov Identifier: NCT00354081.

  19. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kitabata, Hironori; Loh, Joshua P.; Pendyala, Lakshmana K.; Omar, Alfazir; Ota, Hideaki; Minha, Sa’ar; Magalhaes, Marco A.; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Pichard, Augusto D.; Waksman, Ron, E-mail: ron.waksman@medstar.net

    2014-04-15

    Objective: We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). Background: Neoatherosclerosis in neointima has been reported in BMS and in DES. Methods: Thirty patients with 36 stented lesions [BMS (n = 17) or DES (n = 19)] > 3 years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥ 70% diameter stenosis were excluded. Results: The median duration from implantation was 126.0 months in the BMS group and 60.0 months in the DES group (p < 0.001). Lipid-laden intima (58.8% vs. 42.1%, p = 0.317), thrombus (17.6% vs. 5.3%, p = 0.326), and calcification (35.3% vs. 26.3%, p = 0.559) did not show significant differences between BMS and DES. When divided into 3 time periods, the cumulative incidence of lipid-laden neointima from > 3 years to < 9 years was similar between BMS and DES (42.9% vs. 42.1%, p = 1.000). Furthermore, it continued to gradually increase over time in both groups. OCT-derived thin-cap fibroatheroma (TCFA) was observed in 17.6% of BMS- and 5.3% of DES-treated lesions (p = 0.326). No stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p = 0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p = 0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p = 0.361) did not differ significantly. Conclusion: At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES.

  20. Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study.

    Science.gov (United States)

    Rahman, Shahid; Leesar, Tara; Cilingiroglu, Mehmet; Effat, Mohamed; Arif, Imran; Helmy, Tarek; Leesar, Massoud A

    2013-09-01

    Intravascular ultrasound (IVUS) was performed to investigate the impact of kissing balloon inflation (KBI) on the main vessel (MV) stent volume, area, and symmetry after side-branch (SB) dilation in patients with coronary bifurcation lesions (CBL). It remains controversial whether KBI would restore the MV stent area and symmetry loss after SB dilation. A total of 88 serial IVUS examinations of the MV were performed after MV angioplasty, MV stenting, SB dilation, and KBI in 22 patients with CBL. The MV stent was divided into proximal, bifurcation, and distal segments; the stent volume index (SVI), minimal stent area (MSA), stent symmetry index (SSI), and external elastic membrane (EEM) volume index were measured in 198 stent segments and compared after MV stenting, SB dilation, and KBI. In the bifurcation segment, SVI, MSA, and SSI were significantly smaller after SB dilation than after MV stenting and KBI (SVI was 6.10 ± 1.50 mm(3)/mm vs. 6.68 ± 1.60 mm(3)/mm and 6.57 ± 1.60 mm(3)/mm, respectively, p < 0.05; MSA was 5.15 ± 1.30 mm(2) vs. 6.08 ± 1.40 mm(2) and 5.86 ± 1.50 mm(2), respectively, p < 0.05; and SSI was 0.78 ± 0.02 mm(2) vs. 0.87 ± 0.03 mm(2) and 0.84 ± 0.03 mm(2), respectively, p < 0.05). KBI restored the MV SVI, MSA, and SSI after SB dilation. In the proximal segment, SVI, MSA, and EEM volume index were significantly larger, but SSI was smaller after KBI than after MV stenting and SB dilation. In the distal segment, neither SB dilation nor KBI had a significant impact on the MV stent volume or symmetry. This is the first comprehensive volumetric IVUS analysis of CBL, to our knowledge, demonstrating that KBI restores the MV stent volume, area, and symmetry loss after SB dilation in the bifurcation segment, and induces asymmetric stent expansion in the proximal segment. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Imaging of coronary atherosclerosis: Intravascular ultrasound

    NARCIS (Netherlands)

    H.M. Garcia-Garcia (Hector); M.A. Costa (Marco); P.W.J.C. Serruys (Patrick)

    2010-01-01

    textabstractAtherosclerosis is the main cause of coronary heart disease, which is today the leading cause of death worldwide and will continue to be the first in the world in 2030. In the formation of atherosclerotic coronary lesions, a critical primary step is the accumulation and oxidation of low-

  2. Intravascular "mulberry-like" bodies

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Klebe, J G; Henriques, U V

    1988-01-01

    Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesions...... and fetal death was found, the cause of death being attributed to intrauterine asphyxia. It is concluded, that intravascular "mulberry-bodies" most likely represent artifacts due to red blood cell autolysis....

  3. Disseminated intravascular coagulation in cancer patients

    NARCIS (Netherlands)

    M. Levi

    2009-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome that may complicate a variety of diseases, including malignant disease. DIC is characterized by widespread, intravascular activation of coagulation (leading to intravascular fibrin deposition) and simultaneous consumption of coagulation fact

  4. How Is Disseminated Intravascular Coagulation Treated?

    Science.gov (United States)

    ... the NHLBI on Twitter. How Is Disseminated Intravascular Coagulation Treated? Treatment for disseminated intravascular coagulation (DIC) depends ... and treat the underlying cause. Acute Disseminated Intravascular Coagulation People who have acute DIC may have severe ...

  5. Volcano Preparedness

    Science.gov (United States)

    ... You might feel better to learn that an ‘active’ volcano is one that has erupted in the past ... miles away. If you live near a known volcano, active or dormant, following these tips will help you ...

  6. An intravascular protein osmometer.

    Science.gov (United States)

    Henson, J W; Brace, R A

    1983-05-01

    Our purpose was to develop an intravascular osmometer for measuring the colloid (i.e., protein) osmotic pressure (COP) of circulating blood. A semipermeable hollow fiber from a Cordis Dow artificial kidney (C-DAK 4000) was attached to polyethylene tubing on one end, filled with saline, and sealed at the other end. This was small enough to be inserted into the vasculature of research animals. Protein osmotic pressure plus hydrostatic pressure was measured by a Statham pressure transducer attached to the hollow fiber. Simultaneously, a second catheter and transducer was used to measure hydrostatic pressure, which was subtracted from the pressure measured from the fiber with an on-line computer. The system was documented by a variety of tests. The colloid osmotic pressure vs. albumin concentration curve determined with the fiber is identical to the curve determined by standard membrane osmometry. The time constant for 2- and 8-cm fibers was 2.6 +/- 0.6 and 1.5 +/- 0.5 (+/- SD) min, respectively. The reflection coefficient (+/- SD) of the fiber for NaCl is 0.042 +/- 0.019 (n = 38); COP measured at varying temperatures (absolute scale) changed linearly as expected from COP = nCRT (i.e., van't Hoff's law). Finally, hollow-fiber osmometers were inserted into femoral veins of dogs and sheep, and blood COP was continuously recorded during osmotic manipulations. In conclusion, we attempted to develop and document a simple method for continuous measurement of intravascular colloid osmotic pressure.

  7. Intravascular large B cell lymphoma

    Directory of Open Access Journals (Sweden)

    Ricardo García-Muñoz

    2014-01-01

    Full Text Available Intravascular large B cell lymphoma (IVBCL is a rare type of extranodal large B cell lymphoma characterized by selective growth of lymphoma cells within the microvasculature. We present an illustrative case of intravascular B cell lymphoma suspected by the presence of a very small monoclonal B cell population identified by immunophenotype and polymerase chain reaction in bone marrow. The diagnosis was confirmed by skin biopsy.

  8. Vanishing Volcano

    Institute of Scientific and Technical Information of China (English)

    杨树仁

    1995-01-01

    Mauna Loa, the world’s largest active volcano,is sinking into the Pacific Ocean——and it’s taking the main island of Hawaii with it! The problem:The mighty volcano has gained too much weight, says Peter Lipman of the U. S. Geological Survey.

  9. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  10. 虚拟组织学成像血管内超声在冠心病临床治疗中的应用进展%Progress of the Use of Virtual Histology Intravascular Ultrasound in the Study of Treatment of Coronary Artery Disease

    Institute of Scientific and Technical Information of China (English)

    胡晓辉

    2011-01-01

    The virtual histology intravascular ultrasound is characterized by the real-time histological analysis f coronary artery plaque.The use of such technique in coronary heart disease patients suggest that on the virtual histology intravascular ultrasound acute coronary syndrome patients are more frequently complicated with large necrotic core in close contact with the lumen in the absence of fibrous cap.Such plaques also frequently occur in nonculprit arteries with a stenosis less than 50% in diameter for acute coronary syndrome patients, showing a larger necrotic core in proximal arterial plaque.The drug-eluting stent fails to reduce the lipid core and impairs the neogeneration of endothelia in a relative long period.The large necrotic core is associated with the absence of repetfusion during the interventional therapy.The series of studies show that statins decrease the lipid content in plaque but increase that of fibrous tissues.%虚拟组织学成像血管内超声的特点是可以对冠状动脉的斑块进行实时组织学分析.利用这一技术对冠心病患者的研究提示:虚拟组织学成像血管内超声显示的坏死核大、坏死核和管腔直接接触、没有纤维帽的斑块多见于急性冠状动脉综合征患者,也多见于急性冠状动脉综合征患者的直径狭窄<50%的非罪犯血管段,而且冠状动脉的近段斑块坏死核较大;药物洗脱支架没能减少斑块的脂核,且在较长的时间内影响着内皮新生;斑块中大的坏死核与介入治疗时的无复流有关;系列研究显示,他汀治疗可以减少斑块脂质成分,增加纤维组织.

  11. Dante's volcano

    Science.gov (United States)

    1994-09-01

    This video contains two segments: one a 0:01:50 spot and the other a 0:08:21 feature. Dante 2, an eight-legged walking machine, is shown during field trials as it explores the inner depths of an active volcano at Mount Spurr, Alaska. A NASA sponsored team at Carnegie Mellon University built Dante to withstand earth's harshest conditions, to deliver a science payload to the interior of a volcano, and to report on its journey to the floor of a volcano. Remotely controlled from 80-miles away, the robot explored the inner depths of the volcano and information from onboard video cameras and sensors was relayed via satellite to scientists in Anchorage. There, using a computer generated image, controllers tracked the robot's movement. Ultimately the robot team hopes to apply the technology to future planetary missions.

  12. What Are Volcano Hazards?

    Science.gov (United States)

    ... Sheet 002-97 Revised March 2008 What Are Volcano Hazards? Volcanoes give rise to numerous geologic and ... as far as 15 miles from the volcano. Volcano Landslides A landslide or debris avalanche is a ...

  13. Protection against high intravascular pressure in giraffe legs

    DEFF Research Database (Denmark)

    Petersen, Karin K; Hørlyck, Arne; Østergaard, Kristine Hovkjær

    2013-01-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination....... All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure....... revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along...

  14. Ultrasound contrast agents for ultrasound molecular imaging.

    Science.gov (United States)

    Tranquart, F; Arditi, M; Bettinger, T; Frinking, P; Hyvelin, J M; Nunn, A; Pochon, S; Tardy, I

    2014-11-01

    Ultrasound is a real-time imaging technique which is widely used in many clinical applications for its capacity to provide anatomic information with high spatial and temporal resolution. The advent of ultrasound contrast agents in combination with contrast-specific imaging modes has given access to perfusion assessments at an organ level, leading to an improved diagnostic accuracy. More recently, the development of biologically-targeted ultrasound contrast agents has expanded the role of ultrasound even further into molecular imaging applications. Ultrasound molecular imaging can be used to visualize the expression of intravascular markers, and to assess their local presence over time and/or during therapeutic treatment. Major applications are in the field of inflammation and neoangiogenesis due to the strictly intravascular presence of microbubbles. Various technologies have been investigated for attaching the targeting moiety to the shell from simple biotin-avidin constructs to more elaborated insertion within the shell through attachment to PEG residues. This important improvement has allowed a clinical translation of initial pre-clinical investigations, opening the way for an early detection and an accurate characterization of lesions in patients. The combination of anatomic, functional and molecular information/data provided by contrast ultrasound is a powerful tool which is still in its infancy due to the lack of agents suitable for clinical use. The advantages of ultrasound techniques combined with the molecular signature of lesions will represent a significant advance in imaging in the field of personalized medicine. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Central Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction.

    Science.gov (United States)

    Roldan, Carlos J; Paniagua, Linda

    2015-09-01

    Despite the level of skill of the operator and the use of ultrasound guidance, central venous catheter (CVC) placement can result in CVC malpositioning, an unintended placement of the catheter tip in an inadequate vessel. CVC malpositioning is not a complication of central line insertion; however, undiagnosed CVC malpositioning can be associated with significant morbidity and mortality. The objectives of this review were to describe factors associated with intravascular malpositioning of CVCs inserted via the neck and chest and to offer ways of preventing, identifying, and correcting such malpositioning. A literature search of PubMed, Cochrane Library, and MD Consult was performed in June 2014. By searching for "Central line malposition" and then for "Central venous catheters intravascular malposition," we found 178 articles written in English. Of those, we found that 39 were relevant to our objectives and included them in our review. According to those articles, intravascular CVC malpositioning is associated with the presence of congenital and acquired anatomical variants, catheter insertion in left thoracic venous system, inappropriate bevel orientation upon needle insertion, and patient's body habitus variants. Although plain chest radiography is the standard imaging modality for confirming catheter tip location, signs and symptoms of CVC malpositioning even in presence of normal or inconclusive conventional radiography findings should prompt the use of additional diagnostic methods to confirm or rule out CVC malpositioning. With very few exceptions, the recommendation in cases of intravascular CVC malpositioning is to remove and relocate the catheter. Knowing the mechanisms of CVC malpositioning and how to prevent, identify, and correct CVC malpositioning could decrease harm to patients with this condition.

  16. Central Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction

    Directory of Open Access Journals (Sweden)

    Carlos J. Roldan

    2015-10-01

    Full Text Available Despite the level of skill of the operator and the use of ultrasound guidance, central venous catheter (CVC placement can result in CVC malpositioning, an unintended placement of the catheter tip in an inadequate vessel. CVC malpositioning is not a complication of central line insertion; however, undiagnosed CVC malpositioning can be associated with significant morbidity and mortality. The objectives of this review were to describe factors associated with intravascular malpositioning of CVCs inserted via the neck and chest and to offer ways of preventing, identifying, and correcting such malpositioning. A literature search of PubMed, Cochrane Library, and MD Consult was performed in June 2014. By searching for “Central line malposition” and then for “Central venous catheters intravascular malposition,” we found 178 articles written in English. Of those, we found that 39 were relevant to our objectives and included them in our review. According to those articles, intravascular CVC malpositioning is associated with the presence of congenital and acquired anatomical variants, catheter insertion in left thoracic venous system, inappropriate bevel orientation upon needle insertion, and patient’s body habitus variants. Although plain chest radiography is the standard imaging modality for confirming catheter tip location, signs and symptoms of CVC malpositioning even in presence of normal or inconclusive conventional radiography findings should prompt the use of additional diagnostic methods to confirm or rule out CVC malpositioning. With very few exceptions, the recommendation in cases of intravascular CVC malpositioning is to remove and relocate the catheter. Knowing the mechanisms of CVC malpositioning and how to prevent, identify, and correct CVC malpositioning could decrease harm to patients with this condition.

  17. Duplex ultrasound

    Science.gov (United States)

    Vascular ultrasound; Peripheral vascular ultrasound ... A duplex ultrasound combines: Traditional ultrasound: This uses sound waves that bounce off blood vessels to create pictures. Doppler ultrasound: This ...

  18. 血管内超声评价冠脉钙化长度比对介入治疗的影响%Effect of coronary calcification length on percutaneous coronary intervention:An intravascular ultrasound study

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

      目的探讨不同程度冠脉钙化病变对经皮冠脉介入治疗(percutaneous coronary intervention,PCI)疗效的影响。方法连续收集我中心2012年7月-2013年1月71例冠心病患者(71处靶病变),利用血管内超声分析冠脉斑块特征、评估支架植入情况。观察钙化组与非钙化组介入操作特征、即刻疗效和院内主要不良心脏事件(major adverse cardiac events,MACE)。在钙化弧度≤180°和>180°的病变中,对比钙化长度比>0.5与钙化长度比<0.5介入治疗即刻疗效。结果71处靶病变中43处钙化病变,28处非钙化病变。钙化组术后最小支架直径、最小支架横截面积明显小于非钙化组,预扩比例明显增高(P<0.05),支架膨胀指数亦小于非钙化组,但无统计学差异。在钙化弧度≤180°病变中,长钙化组支架膨胀指数明显低于短钙化组(P<0.05)。在钙化弧度>180°的病变中,长钙化组钙化弧度明显大于短钙化组,且支架膨胀指数倾向于小于短钙化组。所有患者均无院内MACE发生。结论冠脉钙化病变影响了支架的充分扩张;钙化弧度≤180°时,如钙化长度比>0.5,则支架的扩张明显受限;钙化弧度>180°时,长钙化病变往往伴随着大弧度钙化,其支架膨胀效果欠佳。%Objective To study the effect of different coronary calcification lengths on percutaneous coronary intervention (PCI). Methods Seventy-one patients (71 target lesions) with coronary heart disease (CHD) admitted to our center from July 2012 to January 2013 were divided into calcification group and non- calcification group. Their coronary artery plaques and stenting were assessed and analyzed by intravascular ultrasonography. The characteristics, immediate outcome and major adverse cardiac events (MACE) of PCI between the two groups were observed. The immediate outcomes of PCI were compared when the ratio of calcification length>0.5 or180

  19. The angle of incidence of the ultrasonic beam: a critical factor for the image quality in intravascular ultrasonography

    NARCIS (Netherlands)

    C. di Mario (Carlo); S. Madretsma; D.T. Linker (David); S.H.K. The (Salem); N. Bom (Klaas); P.W.J.C. Serruys (Patrick); E.J. Gussenhoven (Elma); J.R.T.C. Roelandt (Jos)

    1993-01-01

    textabstractThe effects of the angle of incidence of the ultrasound beam on the image quality were studied in 21 pressurized arterial specimens examined with a 30 MHz intravascular ultrasonographic catheter. When the ultrasonographic catheter was in an eccentric position in the vessel lumen, the

  20. Santorini Volcano

    Science.gov (United States)

    Druitt, T.H.; Edwards, L.; Mellors, R.M.; Pyle, D.M.; Sparks, R.S.J.; Lanphere, M.; Davies, M.; Barreirio, B.

    1999-01-01

    Santorini is one of the most spectacular caldera volcanoes in the world. It has been the focus of significant scientific and scholastic interest because of the great Bronze Age explosive eruption that buried the Minoan town of Akrotiri. Santorini is still active. It has been dormant since 1950, but there have been several substantial historic eruptions. Because of this potential risk to life, both for the indigenous population and for the large number of tourists who visit it, Santorini has been designated one of five European Laboratory Volcanoes by the European Commission. Santorini has long fascinated geologists, with some important early work on volcanoes being conducted there. Since 1980, research groups at Cambridge University, and later at the University of Bristol and Blaise Pascal University in Clermont-Ferrand, have collected a large amount of data on the stratigraphy, geochemistry, geochronology and petrology of the volcanics. The volcanic field has been remapped at a scale of 1:10 000. A remarkable picture of cyclic volcanic activity and magmatic evolution has emerged from this work. Much of this work has remained unpublished until now. This Memoir synthesizes for the first time all the data from the Cambridge/Bristol/Clermont groups, and integrates published data from other research groups. It provides the latest interpretation of the tectonic and magmatic evolution of Santorini. It is accompanied by the new 1:10 000 full-colour geological map of the island.

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  2. Focused intravascular ultrasonic probe using dimpled transducer elements.

    Science.gov (United States)

    Chen, Y; Qiu, W B; Lam, K H; Liu, B Q; Jiang, X P; Zheng, H R; Luo, H S; Chan, H L W; Dai, J Y

    2015-02-01

    High-frequency focused intravascular ultrasonic probes were fabricated in this study using dimple technique based on PMN-PT single crystal and lead-free KNN-KBT-Mn ceramic. The center frequency, bandwidth, and insertion loss of the PMN-PT transducer were 34 MHz, 75%, and 22.9 dB, respectively. For the lead-free probe, the center frequency, bandwidth, and insertion loss were found to be 40 MHz, 72%, and 28.8 dB, respectively. The ultrasonic images of wire phantom and vessels with good resolution were obtained to evaluate the transducer performance. The -6 dB axial and lateral resolutions of the PMN-PT probe were determined to be 58 μm and 131 μm, respectively. For the lead-free probe, the axial and lateral resolutions were found to be 44 μm and 125 μm, respectively. These results suggest that the mechanical dimpling technique has good potential in preparing focused transducers for intravascular ultrasound applications.

  3. High speed intravascular photoacoustic imaging of atherosclerotic arteries (Conference Presentation)

    Science.gov (United States)

    Piao, Zhonglie; Ma, Teng; Qu, Yueqiao; Li, Jiawen; Yu, Mingyue; He, Youmin; Shung, K. Kirk; Zhou, Qifa; Kim, Chang-Seok; Chen, Zhongping

    2016-02-01

    Cardiovascular disease is the leading cause of death in the industrialized nations. Accurate quantification of both the morphology and composition of lipid-rich vulnerable atherosclerotic plaque are essential for early detection and optimal treatment in clinics. In previous works, intravascular photoacoustic (IVPA) imaging for detection of lipid-rich plaque within coronary artery walls has been demonstrated in ex vivo, but the imaging speed is still limited. In order to increase the imaging speed, a high repetition rate laser is needed. In this work, we present a high speed integrated IVPA/US imaging system with a 500 Hz optical parametric oscillator laser at 1725 nm. A miniature catheter with 1.0 mm outer diameter was designed with a 200 μm multimode fiber and an ultrasound transducer with 45 MHz center frequency. The fiber was polished at 38 degree and enclosed in a glass capillary for total internal reflection. An optical/electrical rotary junction and pull-back mechanism was applied for rotating and linearly scanning the catheter to obtain three-dimensional imaging. Atherosclerotic rabbit abdominal aorta was imaged as two frame/second at 1725 nm. Furthermore, by wide tuning range of the laser wavelength from 1680 nm to 1770 nm, spectroscopic photoacoustic analysis of lipid-mimicking phantom and an human atherosclerotic artery was performed ex vivo. The results demonstrated that the developed IVPA/US imaging system is capable for high speed intravascular imaging for plaque detection.

  4. Iatrogenic intravascular pneumocephalus secondary to intravenous catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Yildiz, Altan; Oezer, Caner; Egilmez, Hulusi; Duce, Meltem Nass; Apaydin, Demir F.; Yalcinoglu, Orhan [Department of Radiology, Faculty of Medicine, Mersin University (Turkey)

    2002-03-01

    The presence of pneumocephalus without a history of intracranial or intrathecal procedures is a significant radiographic finding. Although pneumocephalus means a violation of the dural barrier or the presence of infection, intravascular pneumocephalus is different from intraparenchymal pneumocephalus and its benign nature must be known in the presence of intravenous catheterization. Herein, we present a case of iatrogenic intravascular pneumocephalus with CT findings. To our knowledge, there are only a few reported cases of iatrogenic intravascular pneumocephalus in the literature. Careful intravenous catheterization and diagnosis of the condition on imaging helps to prevent unnecessary treatment procedures. (orig.)

  5. Obstetrical disseminated intravascular coagulation score.

    Science.gov (United States)

    Kobayashi, Takao

    2014-06-01

    Obstetrical disseminated intravascular coagulation (DIC) is usually a very acute, serious complication of pregnancy. The obstetrical DIC score helps with making a prompt diagnosis and starting treatment early. This DIC score, in which higher scores are given for clinical parameters rather than for laboratory parameters, has three components: (i) the underlying diseases; (ii) the clinical symptoms; and (iii) the laboratory findings (coagulation tests). It is justifiably appropriate to initiate therapy for DIC when the obstetrical DIC score reaches 8 points or more before obtaining the results of coagulation tests. Improvement of blood coagulation tests and clinical symptoms are essential to the efficacy evaluation for treatment after a diagnosis of obstetrical DIC. Therefore, the efficacy evaluation criteria for obstetrical DIC are also defined to enable follow-up of the clinical efficacy of DIC therapy.

  6. Treatment of Disseminated Intravascular Coagulation.

    Science.gov (United States)

    Makruasi, Nisa

    2015-11-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic activation of blood coagulation, generation of thrombin, and leading to disturbance of the microvasculature. In this article, definition and diagnostic criteria of DIC depend on the International Society of Thrombosis and Haemostasis (ISTH). There is no gold standard for diagnosis of DIC, only low quality evidence is used in general practice. Many diagnostic tests and repeated measurement are required. For the treatment of DIC, there is no good quality evidence. The most important treatment for DIC is the specific treatment of the conditions associated DIC. Platelets and/or plasma transfusion may be also necessary if indicated. Nevertheless, there is no gold standard for diagnosis and treatment of DIC, we use only low quality evidence in general practice.

  7. Experience with intravascular lead extraction

    Institute of Scientific and Technical Information of China (English)

    MA Jian; TANG Kai; WANG Fang-zheng; ZHANG Shu; HUANG Cong-xin

    2005-01-01

    @@ With the increase of clinical use of cardiac pacemaker, a certain kinds of severe leads-related complications (especially infection) have presented in a few patients who underwent pacemaker implantation. The best way to manage this problem is to remove the transvenous leads.1,2 The technique for percutaneous removal of transvenous leads have undergone considerable development in western countries over the past 2 decades. However, there was scarce data on the application of this technique in China. This article reports the results of transvenous extraction of 171 permanent pacemaker leads with the standard lead extraction devices and intravascular countertraction technique during the period from January 1996 to May 2005 in the Center of Arrhythmia Diagnosis and Treatment, Fu Wai Hospital, Beijing, China.

  8. Intravascular Stenting in Microvascular Anastomoses

    DEFF Research Database (Denmark)

    Assersen, Kristine; Sørensen, Jens

    2015-01-01

    Background The effect of intravascular stenting (IVaS) on microvascular anastomoses has given adverse results. For experienced microsurgeons the benefit of IVaS is doubtful. We have investigated the potential benefit of the IVaS technique for two groups of inexperienced microsurgeons with different...... surgical levels of experience (medical students and young residents). Experienced microsurgeons acted as a control group. Materials and Methods In an experimental crossover study, 139 microsurgical anastomoses were performed on the femoral artery in 70 rats by 10 surgeons. On one side of the rat, the IVaS...... spent on the anastomosis. Results No significant difference in patency rates was seen between the stenting and conventional technique in all three groups. The experienced microsurgeons had 100% patency rate with both techniques. The medical students had 20/28 in the IVaS and 19/28 conventional group...

  9. Intravascular ultrasound and virtual histology study on nonculprit lesion in acute coronary syndrome patients with type 2 diabetes mellitus%急性冠状动脉综合征及合并2型糖尿病患者非罪犯病变的血管内超声-虚拟组织学特点的研究

    Institute of Scientific and Technical Information of China (English)

    郑婕舒; 张元春; 贺迅; 戴磊; 罗常有; 刘祖恒; 尹庆; 王善花; 苏伟平

    2013-01-01

    目的 急性冠状动脉综合征(ACS)及合并T2DM患者非罪犯病变的血管内超声-虚拟组织学(IVUS-VH)特点与罪犯病变进行比较,为临床处理非罪犯病变提供参考. 方法 选取ACS患者60例,其中合并T2DM 17例,入选者分别行3条血管IVUS-VH检查,测量病变的IVUS-VH指标,检出薄纤维帽粥样斑块(VH-TCFA),确定罪犯病变后分为罪犯病变组(A组)与非罪犯病变组(B组)进行比较.结果 两组VH-TCFA检出率一致(66.7%vs66.7%,P=1.000). 结论 ACS患者(包括合并T2DM)非罪犯病变同样具有易损性.%Objective To compare the characteristics of non-culprit lesion with culprit lesion in acute coronary syndrome (ACS) patients with T2DM to provide the references for the clinical management of non-culprit lesion.Methods The 3-vessel intravascular ultrasound and virtual history (IVUS-VH) analysis was performed for 60 ACS patients,17 of them with T2DM.The parameters of IVUS-VH were measured for all the lesions.The thin-cap fibroatheromas (VH-TCFA) were detected.After the culprit lesion was diagnosed first,the culprit and nonculprit lesion groups were compared to observe the characteristics between them.Results The detectable rate of IVUS-VH derived thin-cap fibroatheroma (VH-TCFA) was the same (66.7% vs 66.7%,P=1.000) in the nonculprit versus culprit lesion groups.Conclusion Nonculprit.lesion is vulnerable in ACS patients (some of them with T2DM).

  10. Intravascular ultrasound in guiding endovascular aortic aneurysm repair-a case report of interventional therapy without contrast media%血管内超声介导下主动脉夹层腔内修复术无造影剂介入治疗1例报道

    Institute of Scientific and Technical Information of China (English)

    罗建方; 黄文晖; 谢年谨; 胡孜阳; 刘媛; 杨峻青; 范瑞新; 陈纪言

    2011-01-01

    Objectives To investigate the feasibility and clinical value of intravascular ultrasound (IVUS) in guiding endovascular aortic aneurysm repair (EVAR). Methods With EVAR procedure for a patient suffered from Standford type B aortic dissection and renal insufficiency, we utilized IVUV to guide the lumen tracking, rupture site localization, stent delivery and intra-procedure examination of anatomic result. We attempted to avoid any dose of iodic contrast. Results Zero milliliter iodic contrast was consumed in the procedure and this procedure lasted for 12S minutes. The operation was smoothly performed and anatomic result was satisfactory. No complication occurred after operation. The patient's concentration of serum creatinine did not increase within a week monitor. Conclusions IVUS guided EVAR is feasible in this patients. Iodic contrast may be avoided with the utilization of this technique and sequentially renal function be protected.%目的 探讨血管内超声代替基于造影剂的血管显影指引主动脉腔内修复术的可行性和价值.方法 我们对1例Standford B型主动脉夹层合并肾功能不全患者行主动脉腔内修复术,术中使用血管内超声指引寻腔、定位、支架释放和进行解剖学检查,全程避免使用造影剂.结果 手术使用造影剂0 mL,手术时间125 min,寻腔、定位及支架释放过程顺利.支架到位准确,扩张及贴壁良好.术后无内漏或新发夹层,无其他并发症.术后1周患者血清肌酐浓度无增高.结论在本例患者中,血管内超声代替基于造影剂的血管显影指引主动脉腔内修复术可行,该技术可能避免肾功能不全患者肾功能恶化.

  11. Comparative study of the intravascular ultrasound and optical coherence tomography in stenting strategy selection and its prognostic impact in coronary bifurcation lesions%血管内超声与光学相干断层显像对冠状动脉分叉病变手术策略及预后影响的对照研究

    Institute of Scientific and Technical Information of China (English)

    殷拥军; 孔令秋; 张宏才; 伍洲; 赵珏; 黄大军; 许勇; 聂谦

    2016-01-01

    Objective To investigate the reliability of the intravascular ultrasound(IVUS)and optical coherence tomography(OCT)in stenting strategy selection and its prognostic impact in coronary bifurcation lesions.Methods A total of 157 patients with coronary artery disease were prospectively studied by using angiography,OCT,and IVUS. Quantitative image analyses of the coronary bifurcation lesions were performed.The stenting strategy selection and its prognostic impact were evaluated.Results In the clinical study,the mean minimum lumen diameter(MLD)and the minimum lumen area(MLA) measured by QCA were significantly smaller than those measured by IVUS and OCT (P 0.05),although the OCT seems better in the follow-up.Conclusions IVUS and OCT provide accurate and reproducible quantitative measurements of coronary artery,all of them were reliable in stenting strategy selection.%目的:对比血管内超声(IVUS)及光学相干断层显像(OCT)对冠状动脉分叉病变经皮冠状动脉介入治疗(PCI)手术策略选择及预后的影响。方法冠状动脉造影明确为分叉病变的患者157例,使用冠状动脉定量分析(QCA)测量最小管腔直径(MLD)、最小管腔横截面积(MLA)、参照管腔直径(RLD),其后随机进行 IVUS (84例)和 OCT检查(73例),测量并比较上述参数与 QCA测值的差异;比较不同方法所指导的支架植入方案心血管事件发生率。结果通过 IVUS 及 OCT 所测冠状动脉 MLD、MLA、RLD 均高于 QCA 法,其中 MLD、MLA 差异有统计学意义(P 0.05)。结论IVUS 和OCT 均可用于指导分叉病变患者PCI 策略选择。

  12. Ultrasound in trauma.

    Science.gov (United States)

    Rippey, James C R; Royse, Alistair G

    2009-09-01

    Point-of-care ultrasound is well suited for use in the emergency setting for assessment of the trauma patient. Currently, portable ultrasound machines with high-resolution imaging capability allow trauma patients to be imaged in the pre-hospital setting, emergency departments and operating theatres. In major trauma, ultrasound is used to diagnose life-threatening conditions and to prioritise and guide appropriate interventions. Assessment of the basic haemodynamic state is a very important part of ultrasound use in trauma, but is discussed in more detail elsewhere. Focussed assessment with sonography for Trauma (FAST) rapidly assesses for haemoperitoneum and haemopericardium, and the Extended FAST examination (EFAST) explores for haemothorax, pneumothorax and intravascular filling status. In regional trauma, ultrasound can be used to detect fractures, many vascular injuries, musculoskeletal injuries, testicular injuries and can assess foetal viability in pregnant trauma patients. Ultrasound can also be used at the bedside to guide procedures in trauma, including nerve blocks and vascular access. Importantly, these examinations are being performed by the treating physician in real time, allowing for immediate changes to management of the patient. Controversy remains in determining the best training to ensure competence in this user-dependent imaging modality.

  13. Obstetrical Ultrasound

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Obstetric Ultrasound Obstetric ultrasound uses sound waves to produce pictures ... limitations of Obstetrical Ultrasound Imaging? What is Obstetrical Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  14. Prostate Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves ... the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and ...

  15. Musculoskeletal Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Musculoskeletal Ultrasound imaging uses sound waves to produce ... Ultrasound Imaging of the Musculoskeletal System? What is Ultrasound Imaging of the Musculoskeletal System? Ultrasound is safe ...

  16. Ultrasound - Scrotum

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Scrotum Ultrasound imaging of the scrotum uses sound ... of Ultrasound Imaging of the Scrotum? What is Ultrasound Imaging of the Scrotum? Ultrasound imaging of the ...

  17. Ultrasound -- Vascular

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Vascular Vascular ultrasound uses sound waves to evaluate ... the limitations of Vascular Ultrasound? What is Vascular Ultrasound? Ultrasound is safe and painless, and produces pictures ...

  18. Hip Ultrasound

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Hip Ultrasound Hip ultrasound uses sound waves to produce pictures ... of Ultrasound Imaging of the Hip? What is Ultrasound Imaging of the Hip? Ultrasound images of the ...

  19. Ultrasound -- Vascular

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound - Vascular Vascular ultrasound uses sound waves to evaluate the ... are the limitations of Vascular Ultrasound? What is Vascular Ultrasound? Ultrasound is safe and painless, and produces ...

  20. Intravascular ultrasound for iliac artery imaging. Clinical review

    DEFF Research Database (Denmark)

    Vogt, K G; Schroeder, T V

    2001-01-01

    PTA. Structures such as rupture, intimal flaps and dissection are better visualized with IVUS. In stenotic iliac arteries IVUS has been able to evaluate the effect of PTA and stenting and relating the effect to the morphology of the plaque. IVUS measurements seem to be important predictors...... of the patency of iliac PTA. The ability of IVUS to evaluate the adaptation of stents to the arterial wall makes it particularly suited as a control procedure for the deployment of endovascular stented grafts. Finally IVUS has the ability to disclose insufficiency of endarterecomy, by visualizing remaining...

  1. Prediction of outcome after femoropopliteal balloon angioplasty by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K C; Just, S; Rasmussen, John Bøje Grønvall

    1997-01-01

    arteries remained patent. Two occlusions and two stenoses developed during the first 3 months after the intervention and one occlusion occurred after 1 year. The following IVUS parameters were related to a favourable patency: presence of calcification; dissection or plaque rupture and residual stenosis...

  2. Coagulación intravascular diseminada = Disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Arango Barrientos, Marcos

    2010-12-01

    Full Text Available La coagulación intravascular diseminada (CID es una entidad clínica frecuente que se presenta como fenómeno secundario a diversas enfermedades entre las cuales se destacan las infecciones graves, las neoplasias y las catástrofes obstétricas. Se caracteriza por una activación difusa y simultánea de los sistemas endógenos de la coagulación y la fibrinólisis. El depósito de pequeños trombos en la circulación conduce finalmente a disfunción orgánica múltiple y en algunos casos a la muerte. Las manifestaciones clínicas pueden incluir fenómenos trombóticos y hemorrágicos. Se ha propuesto un puntaje de fácil aplicación para simplificar el diagnóstico de la entidad. El tratamiento incluye el control específico de la causa subyacente que favorece la aparición de la CID, el soporte con hemoderivados en pacientes con manifestaciones de sangrado y la anticoagulación terapéutica en pacientes con trombosis mayores. El desarrollo de CID es un factor pronóstico adverso que aumenta significativamente la tasa de mortalidad. En este artículo de revisión se incluyen los siguientes aspectos de la CID: historia, epidemiología, clasificación, entidades asociadas, fisiopatología, clínica, diagnóstico, tratamiento y pronóstico.

  3. Dosimetry in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing {sup 32} P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  4. Global Volcano Locations Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NGDC maintains a database of over 1,500 volcano locations obtained from the Smithsonian Institution Global Volcanism Program, Volcanoes of the World publication. The...

  5. A feasibility study of an intravascular imaging antenna to image atherosclerotic plaques in Swine using 3.0 T MRI.

    Directory of Open Access Journals (Sweden)

    Chen Zhang

    Full Text Available To investigate the feasibility of an intravascular imaging antenna to image abdominal aorta atherosclerotic plaque in swine using 3.0T magnetic resonance imaging (MRI.Atherosclerotic model was established in 6 swine. After 8 months, swine underwent an MR examination, which was performed using an intravascular imaging guide-wire, and images of the common iliac artery and the abdominal aorta were acquired. Intravascular ultrasound (IVUS was performed in the right femoral artery; images at the same position as for the MR examination were obtained. The luminal border and external elastic membrane of the targeted arteries were individually drawn in the MR and IVUS images. After co-registering these images, the vessel, lumen, and vessel wall areas and the plaque burden in the same lesions imaged using different modalities were calculated and compared. The diagnostic accuracy of intravascular MR examination in delineating the vessel wall and detecting plaques were analyzed and compared using IVUS.Compared with IVUS, good agreement was found between MRI and IVUS for delineating vessel, lumen, and vessel wall areas and plaque burden (r value: 0.98, 0.95, 0.96 and 0.91, respectively; P<0.001.Compared with IVUS, using an intravascular imaging guide-wire to image deep seated arteries allowed determination of the vessel, lumen and vessel wall areas and plaque size and burden. This may provide an alternative method for detecting atherosclerotic plaques in the future.

  6. A Scientific Excursion: Volcanoes.

    Science.gov (United States)

    Olds, Henry, Jr.

    1983-01-01

    Reviews an educationally valuable and reasonably well-designed simulation of volcanic activity in an imaginary land. VOLCANOES creates an excellent context for learning information about volcanoes and for developing skills and practicing methods needed to study behavior of volcanoes. (Author/JN)

  7. Application of intravascular ultrasound in analysis on influencing factors of prognosis in patients with different coronary artery in-stent restenosis%血管内超声在冠状动脉支架术后再狭窄患者预后影响因素分析中的应用

    Institute of Scientific and Technical Information of China (English)

    崔燕; 史永锋; 郭子源; 刘斌; 王金鹏; 赵雷; 王珺楠; 朴金花

    2016-01-01

    目的:收集应用血管内超声技术(IVUS)检测发生冠状动脉支架术后支架内再狭窄(ISR)患者的影像学数据及相关资料,分析 ISR 的危险因素,提出合理的干预策略。方法:将50例 ISR 患者随机分为 ISR≤50%组(药物组)14例和 ISR>50%组36例(根据患者意愿及经济情况分为药物球囊治疗组16例和支架治疗组20例)。应用 IVUS 虚拟组织学技术,比较各组患者采用不同治疗方法治疗前后斑块面积、病变位置、组织构成和血栓等影响预后的因素,并随访6个月后的数据变化。结果:IVUS 检测,与术前比较,行介入干预治疗的ISR 患者斑块面积和斑块负荷均明显减少(P <0.05),但药物球囊治疗组患者斑块缩减程度小于支架治疗组(P <0.05),纤维组织成分无明显变化(P >0.05),钙化组织所占比例升高,但差异无统计学意义(P >0.05)。结论:病变狭窄程度高且纤维成分多,斑块成分不均一且分布弥漫伴迂曲钙化的患者 ISR 发生率均较高。ISR发生与斑块壁厚薄、脂质成分含量、斑块不稳定程度和坏死组织多少无明显关联。%Objective:To collect the imaging data and related materials of the patients with in-stent restenosis (ISR)after coronary artery stent operation with intravascular ultrasound (IVUS),and to analyze the risk factors of ISR,and to propose the reasonable intervention strategies.Methods:Fifty patients with ISR were divided into ISR ≤ 50% drug group (n = 14 )and ISR > 50% drug group (n = 36),including drug-coated balloon therapy group (n=16)and stent treatment group (n=20);IVUS virtual organization technology was used to compare the plaque area,location,tissue composition,thrombus and other factors of the patients in various groups after treatment;the data changes after 6 months of follow-up were analyzed.Results:The IVUS results showed the plaque areas and plaque loads of the

  8. Effects of fluvastatin extended release tablets on the intermediate lesions of patients with coronary artery disease evaluated by virtual histology-intravascular ultrasound%虚拟组织学-血管内超声观察氟伐他汀缓释片对冠状动脉临界病变的影响

    Institute of Scientific and Technical Information of China (English)

    杨海波; 赵晓燕; 赵荫涛; 张金盈; 李凌

    2012-01-01

    Objective To obserrve the effect of fluvastatin extended release tablets on the intermediate lesions of patients with coronmy artery disease evaluated by virtual histology-intravascular ultrasound(VH-IVUS).Methods Forty-three patients with intermediate lesions of acute coronary syndrome (ACS) were examined by coronary angiography (CAG) and VH-IVUS,the target vessel diameter stenosis (DS) were analyzed using quantitative coronary angiography (QCA).The plaque burden,minimal luman area(MLA) and composition variation were analyzed using VH-IVUS.All selected patients were treated with 80 mg fluvastatin extended release tablets for 6 months.The serum lipid levels of patients before and after the treatment were compared.After 6 months the reexamination of the vessel by CAG and VH-IVUS were performed.Results After 6 months,the TC,LDL-C and TG levels were significantly decreased,while the HDL-C level was significantly increased (P < 0.05).The VH-IVUS analysis showed that the proportion of necrosis core was decreased from (22.6 ± 7.5) % to (15.1 ± 7.1) %(P < 0.05) and the proportion of fibrous tissue was increased from (44.4 ± 9.7) % to (51.2 ± 9.9) %(P < 0.05).There has no significant change in DS,the plaque burden,MLA,the proportion of dense calcium or fibro-fatty tissue.Conclusions The treatment of fluvastatin for 6 months might stable plaque and prevent the progression of atherosclerosis in patients with intermediate coronary artery lesions.%目的 应用虚拟组织学-血管内超声(VH-IVUS)观察氟伐他汀缓释片对冠状动脉临界病变患者斑块进展及其成分的影响.方法 选择经冠状动脉造影(CAG)和VH-IVUS检查无需介入治疗的冠状动脉临界病变患者43例,给予氟伐他汀缓释片(80 mg)治疗6个月后复查CAG及VH-IVUS,比较治疗前后血脂、定量冠状动脉造影(QCA)分析目标血管段直径狭窄率(DS)变化,VH-IVUS分析斑块负荷、最小管腔面积(MLA)、斑块成分变化.结果

  9. 血脂与血管内超声-虚拟组织学评价冠状动脉粥样硬化斑块性质%Correlation between blood lipid and intravascular ultrasound-virtual histology in assessing characteristics of coronary atherosclerotic plaques

    Institute of Scientific and Technical Information of China (English)

    武丽娜; 李新华; 赵晓燕

    2012-01-01

    目的:探讨血脂和血管内超声-虚拟组织(IVUS-VH)学评价急性冠脉综合征(ACS)和稳定性心绞痛(SA)患者冠状动脉粥样硬化斑块性质.方法:对44例ACS患者及22例SA患者行IVUS-VH分析,并对其血清高密度脂蛋白胆固醇(HDL-C)、低密度脂蛋白胆固醇(LDL-C)、脂蛋白a [LP(a)]进行测定,计算LDL-C/HDL-C比值,分析冠状动脉粥样硬化斑块坏死核心(NC)所占的比例与LP(a)、LDL-C/HDL-C的相关关系.结果:ACS组斑块中NC和钙化组织比例明显高于SA组(t=4.669、9.894,P<0.001),而纤维组织及纤维脂肪组织则明显低于SA组(t=7.184、5.290,P<0.001).ACS组患者血清LDL-C/HDL-C、LP(a)水平高于SA组患者(t=3.512、19.139,P<0.001).ACS组患者冠状动脉粥样硬化斑块中NC比例与血清LP(a)水平有显著的相关性(r=0.549,P<0.001).结论:LP(a)可能代替IVUS-VH帮助了解冠状动脉粥样硬化斑块的性质.%Aim: To investigate the correlation between blood lipid and intravascular ultrasound-virtual histology(IVUS-VH) in assessing characteristics of the coronary atherosclerotic plaques in patients with acute coronary syndrome(ACS) and stable angina(SA).Methods:The coronary atherosclerotic plaques in 44 patients with ACS and 22 patients with SA were tested by IVUS-VH,and the serum levels of HDL-C,LDL-C and LP(a) were detected. The ratio of LDL-C/HDL-C was calculated.The correlation of the percentage of necrotic core and LP(a),LDL-C/HDL-C was analyzed,respectively.Results:The percentages of necrotic core and dense calcium tissue in ACS were significantly higher than those in SA group (t=4.669,9.894,P<0.001),but the percentages of fibrous tissue and fibro-fatty tissue in ACS were significantly lower than those in SA group(t=7.184,5.290,P<0.001).There were obvious differences in serum level of LP(a) and the ratio of LDL-C/HDL-C between ACS group and SA group (t=3.512,19.139,P<0.001). There was a significant positive correlation between the percentage of necrotic core

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  11. Volcano seismology

    Science.gov (United States)

    Chouet, B.

    2003-01-01

    A fundamental goal of volcano seismology is to understand active magmatic systems, to characterize the configuration of such systems, and to determine the extent and evolution of source regions of magmatic energy. Such understanding is critical to our assessment of eruptive behavior and its hazardous impacts. With the emergence of portable broadband seismic instrumentation, availability of digital networks with wide dynamic range, and development of new powerful analysis techniques, rapid progress is being made toward a synthesis of high-quality seismic data to develop a coherent model of eruption mechanics. Examples of recent advances are: (1) high-resolution tomography to image subsurface volcanic structures at scales of a few hundred meters; (2) use of small-aperture seismic antennas to map the spatio-temporal properties of long-period (LP) seismicity; (3) moment tensor inversions of very-long-period (VLP) data to derive the source geometry and mass-transport budget of magmatic fluids; (4) spectral analyses of LP events to determine the acoustic properties of magmatic and associated hydrothermal fluids; and (5) experimental modeling of the source dynamics of volcanic tremor. These promising advances provide new insights into the mechanical properties of volcanic fluids and subvolcanic mass-transport dynamics. As new seismic methods refine our understanding of seismic sources, and geochemical methods better constrain mass balance and magma behavior, we face new challenges in elucidating the physico-chemical processes that cause volcanic unrest and its seismic and gas-discharge manifestations. Much work remains to be done toward a synthesis of seismological, geochemical, and petrological observations into an integrated model of volcanic behavior. Future important goals must include: (1) interpreting the key types of magma movement, degassing and boiling events that produce characteristic seismic phenomena; (2) characterizing multiphase fluids in subvolcanic

  12. [A method for studying intravascular platelet aggregation in vitro].

    Science.gov (United States)

    Ikonnikova, E I; Chernousova, L A; Moshkina, I R

    1999-06-01

    A simple available method for evaluating intravascular platelet aggregation is proposed. It consists in graphic recording of disaggregation of platelet-rich citrate plasma, which indicates the degree of intravascular aggregation. Intravascular aggregation is notably increased in coronary patients and negligible in normal subjects. The method may be used for the diagnosis of diseases with a high thrombogenic risk.

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are the limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and painless, ... through the blood vessels. top of page How is the procedure performed? Transabdominal: For most ultrasound exams, ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate gland ... of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or sonography , ...

  16. Ultrasound - Breast

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound - Breast Ultrasound imaging of the breast uses sound waves ... the Breast? What is Ultrasound Imaging of the Breast? Ultrasound is safe and painless, and produces pictures ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  20. Volcanoes: Nature's Caldrons Challenge Geochemists.

    Science.gov (United States)

    Zurer, Pamela S.

    1984-01-01

    Reviews various topics and research studies on the geology of volcanoes. Areas examined include volcanoes and weather, plate margins, origins of magma, magma evolution, United States Geological Survey (USGS) volcano hazards program, USGS volcano observatories, volcanic gases, potassium-argon dating activities, and volcano monitoring strategies.…

  1. Foci of Volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, I.

    1974-01-01

    One may assume a center of volcanic activities beneath the edifice of an active volcano, which is here called the focus of the volcano. Sometimes it may be a ''magma reservoir''. Its depth may differ with types of magma and change with time. In this paper, foci of volcanoes are discussed from the viewpoints of four items: (1) Geomagnetic changes related with volcanic activities; (2) Crustal deformations related with volcanic activities; (3) Magma transfer through volcanoes; and (4) Subsurface structure of calderas.

  2. Membrane design of an all-optical ultrasound receiver

    NARCIS (Netherlands)

    Leinders, S.M.; Dongen, K.W.A. van; Jong, N. de; Verweij, M.D.; Westerveld, W.J.; Urbach, H.P.; Neer, P.L.M.J. van; Pozo Torres, J.M.

    2013-01-01

    Ultrasound sensors such as piezoelectric transducers and CMUTs are successfully used for medical imaging. However, especially wiring of individual elements is difficult in the fabrication of small piezoelectric arrays, used in, e.g. the field of intravascular imaging. As an alternative, we designed

  3. 血管内超声评价国产瑞舒伐他汀对冠状动脉轻中度狭窄病变的影响%Effects of domestic rosuvastatin on coronary plaque in patients with mild-to-moderate coronary artery stenosis as evaluated by virtual histology-intravascular ultrasound

    Institute of Scientific and Technical Information of China (English)

    杨海波; 赵晓燕; 赵荫涛; 张金盈; 李凌

    2012-01-01

    目的 应用虚拟组织学-血管内超声(VH-IVUS)评价国产瑞舒伐他汀对急性冠脉综合征患者冠状动脉轻中度狭窄病变斑块进展及成分的影响.方法 选择经冠状动脉造影(CAG)和VHIVUS检查无需介入治疗的冠脉轻中度狭窄病变患者83例,分为试验组42例和对照组41例,试验组给予国产瑞舒伐他汀(瑞旨10 mg,每晚1次),对照组给予进口瑞舒伐他汀(可定10 mg,每晚1次),治疗6个月后复查血脂、CAG及VH-IVUS,比较两组间血脂变化、定量冠脉造影分析靶病变处直径狭窄(DS)变化,VH-IVUS分析靶病变处斑块负荷、最小管腔面积(MLA)和斑块成分变化.结果 瑞舒伐他汀干预6个月后,VH-IVUS分析显示,两组患者斑块坏死核心比例比治疗前明显减少(试验组:14.8%±7.0%比22.6%±7.5%,P<0.05,对照组:14.9%±7.1%比23.1% ±7.7%,P<0.05)、纤维组织比例明显增加(试验组:51.5%±9.9%比44.5%±9.7%,P< 0.05,对照组:51.4%±10.1%比44.3%±9.8%,P<0.05),两组患者血脂水平明显改善(P<0.05),而DS、斑块负荷、MLA、纤维脂质组织比例、钙化组织比例无明显变化(P>0.05).结论 国产瑞舒伐他汀治疗冠脉轻中度狭窄病变可稳定斑块,并延缓斑块进一步发展.%Objective To evaluate the effects of domestic rosuvastatin tablets on coronary plaque in the patients with mild-to-moderate coronary artery stenosis through virtual histology-intravascular ultrasound (VH-IVUS).Methods Eighty-three patients with mild-to-moderate coronary artery stenosis of acute coronary syndrome( ACS)were enrolled and randomized into test group (domestic rosuvastatin,10 mg/day,n =42) or control group ( CRESTOR,10 mg/day,n =41 ).The serum lipid levels,diameter stenosis (DS)on quantitative coronary angiography (QCA),MLA (minimal lumen area),plaque burden and component of target lesion on VH-IVUS were evaluated at baseline and at 6-month follow-up.Results After 6 months,the levels of

  4. Combined use of optical coherence tomography and intravascular ultrasound during percutaneous coronary intervention in patients with coronary artery disease%光学相干断层成像和血管内超声在冠状动脉介入手术中的应用

    Institute of Scientific and Technical Information of China (English)

    侯静波; 孟令波; 景慎鸿; 韩志刚; 于淮; 于波

    2008-01-01

    目的 应用光学相干断层成像(OCT)及血管内超声(IVUS)检测技术评价冠状动脉内粥样硬化斑块的稳定性,并指导支架置入,检测血管对置入支架后即刻和中远期的反应.方法 选择2008年2-7月间的27例患者,进行冠状动脉造影、OCT及IVUS检查,共检查了30支血管,其中8处为药物支架植入术后血管,并对19处病变进行了支架置入.结果 除外支架置入的8例(置入6个月~4年)外,其余22例病变行OCT及IVUS检查,发现稳定性斑块5例,不稳定斑块17例,其中OCT检出内膜小撕裂4例(IVUS未检出,P>0.05),冠状动脉撕裂伴夹层病变5例(IVUS检出1例,P>0.05),血栓形成5例(IVUS检出1例,P>0.05),偏心斑块伴薄纤维帽12例(IVUS检出2例,P<0.01).8例曾经进行支架治疗的患者,造影、OCT和IVUS发现2例再狭窄;OCT显示支架内膜覆盖良好,IVUS小能精确看到内膜;OCT检测出1例患者有支架后瘤样扩张.对17例不稳定性斑块及2例支架再狭窄病例行支架置入术,术后支架膨胀不良发生率26.0%,OCT及IVUS检出率相同;支架贴壁不良发生率63.2%,IVUS榆出率低于OCT(10.5%比63.2%,P<0.01);支架近远端撕裂10.5%,IVUS均不能检出;内膜脱垂发生率52.6%,IVUS检出率低于OCT(10.5%比52.6%,P<0.05).结论 OCT与IVUS相比,在不稳定性斑块检测准确度方面明显优于IVUS,更能精确指导冠状动脉支架置人.IVUS在操作简便性及反映斑块负荷方面要优于OCT.%Objective To evaluate the value of combined optical coherence tomography (OCT) and intravascular ultrasound (IVUS) examinations in detecting coronary artery plaque during percutaneous transluminal coronary intervention (PCI).Methods CICT and IVUS examinations were performed on 30 diseased coronary vessels from 27 patients underwent PCI from Feb.2008 to Jul.2008.Results Seventeen vulnerable plaques (4 intima tearing which were not detected by IVUS),5 plaque rupture (1 out of 5 was detected by IVUS),5 thrombus

  5. Techniques for Intravascular Foreign Body Retrieval

    Energy Technology Data Exchange (ETDEWEB)

    Woodhouse, Joe B.; Uberoi, Raman, E-mail: raman.uberoi@orh.nhs.uk [Oxford University Hospitals (United Kingdom)

    2013-08-01

    As endovascular therapies increase in frequency, the incidence of lost or embolized foreign bodies is increasing. The presence of an intravascular foreign body (IFB) is well recognized to have the potential to cause serious complications. IFB can embolize and impact critical sites such as the heart, with subsequent significant morbidity or mortality. Intravascular foreign bodies most commonly result from embolized central line fragments, but they can originate from many sources, both iatrogenic and noniatrogenic. The percutaneous approach in removing an IFB is widely perceived as the best way to retrieve endovascular foreign bodies. This minimally invasive approach has a high success rate with a low associated morbidity, and it avoids the complications related to open surgical approaches. We examined the characteristics, causes, and incidence of endovascular embolizations and reviewed the various described techniques that have been used to facilitate subsequent explantation of such materials.

  6. [Disseminated intravascular coagulation in solid tumours].

    Science.gov (United States)

    Ferrand, François Régis; Garcia-Hejl, Carine; Moussaid, Yassine; Schernberg, Antoine; Bidard, François-Clément; Pavic, Michel; Khenifer, Safia; Stoclin, Annabelle

    2014-06-01

    Disseminated intravascular coagulation (DIC) is a complex abnormality of hemostasis with dramatic consequences and long described as associated with tumors. Yet the diagnosis and management of paraneoplastic DIC are poorly defined. The purpose of this paper is to review DIC associated with solid tumors, at the pathophysiological and therapeutic levels in particular. We also report data from a recent retrospective series of patients with DIC in the context of a solid tumor, to illustrate the epidemiological, clinical and prognostic.

  7. Temporary intravascular shunts for peripheral vascular trauma.

    Directory of Open Access Journals (Sweden)

    Husain A

    1992-04-01

    Full Text Available Polyvinylchloride (PVC disposable endotracheal suction catheters were successfully used as temporary intravascular shunts in 5 patients of popliteal artery trauma. These simple shunts should be used routinely in such conditions to immediately re-establish blood supply to the ischaemic limb particularly in patients of polytrauma where systemic anticoagulation is contraindicated. This avoids the inherent delay prior to vascular repair and reduces the incidence of irreversible ischemia.

  8. Diagnosis and treatment of disseminated intravascular coagulation.

    Science.gov (United States)

    Levi, M

    2014-06-01

    Disseminated intravascular coagulation (DIC) is a condition in which systemic activation of coagulation without a specific localization occurs, resulting in extensive formation of intravascular fibrin, particularly in small and midsize vessels. Disseminated intravascular coagulation may lead to several altered coagulation parameters, including a low platelet count, abnormal global clotting assays, low levels of physiological anticoagulant proteases, or increased fibrin degradation products. Also, more complex assays for activation of coagulation factors or pathways may indicate involvement of these molecules in DIC. None of these tests alone, however, can accurately ascertain or rebuff a diagnosis of DIC. Nonetheless, a combination of readily available routine assays may be instrumental in establishing a diagnosis of DIC and can also be useful to point to a subset of patients with DIC that may need definite, often costly, interventions in the hemostatic system. Current insights on relevant etiological pathways that may contribute to the occurrence of DIC have led to innovative therapeutic and adjunctive approaches to patient with DIC. Management options directed at the amelioration of hemostatic activation may tentatively be indicated and were found to be advantageous in experimental and clinical investigations. These treatments encompass elimination of tissue factor-mediated thrombin generation or restitution of normal anticoagulant function.

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... are the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe ... transducer into the body. top of page How is the procedure performed? In men, the prostate gland ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and organs ... of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or sonography , ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  16. Hypothesis: Disseminated Intravascular Inflammation as the Inflammatory Counterpart to Disseminated Intravascular Coagulation

    Science.gov (United States)

    Bull, Brian S.; Bull, Maureen H.

    1994-08-01

    We have identified a leukocyte activation syndrome that is occasionally associated with the transfusion of intraoperatively recovered erythrocytes. This syndrome appears to result from intravascular damage caused by leukocytes activated during the erythrocyte salvage process. We hypothesize that this syndrome is part of a larger disease grouping: disseminated intravascular inflammation (DII). DII is the analog of the coagulation disorder disseminated intravascular coagulation. In disseminated intravascular coagulation, the organ damage results from uncontrolled activation of the clotting pathway; in DII the damage is caused by leukocytes that have become activated by direct contact with bacteria or in rare instances-such as erythrocyte salvage-in the absence of bacteria and bacterial products. Recent studies of the hazards associated with intraoperative blood salvage indicate that activation of leukocytes can be achieved by exposure to activated platelets alone. If such activated leukocytes are reinfused along with the washed erythrocytes, widespread organ damage may result. The lung is the organ most severely affected by activated leukocytes. Adult respiratory distress syndrome is one outcome. It is likely that DII is a presently unrecognized pathophysiological process that complicates a variety of primary disease states and increases their lethality.

  17. Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound

    Directory of Open Access Journals (Sweden)

    John R. Eisenbrey

    2015-01-01

    Full Text Available Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency, subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imaging in vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.

  18. Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound.

    Science.gov (United States)

    Eisenbrey, John R; Sridharan, Anush; Liu, Ji-Bin; Forsberg, Flemming

    2015-01-01

    Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency), subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imaging in vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.

  19. Volcanoes - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer includes Holocene volcanoes, which are those thought to be active in the last 10,000 years, that are within an extended area of the northern...

  20. Italian active volcanoes

    Institute of Scientific and Technical Information of China (English)

    RobertoSantacroce; RenawCristofolini; LuigiLaVolpe; GiovanniOrsi; MauroRosi

    2003-01-01

    The eruptive histories, styles of activity and general modes of operation of the main active Italian volcanoes,Etna, Vulcano, Stromboli, Vesuvio, Campi Flegrei and Ischia, are described in a short summary.

  1. The Diagnosis and Man Disseminated Intravascular Coagulation

    Institute of Scientific and Technical Information of China (English)

    Flelcher B.; Taylor.Jr

    2003-01-01

    @@ This review describes disseminated intravascular coagulation(DIC) as a syndrome in which hemostatic factors are activated and products are generated. This syndrome ranges in severity from an obvious decompensated coagulopathy (overt-DIC) to the subclinical compensated activation of hemostatic factors(non-overt DIC). Ths first part of this review emphasizes two points: First, activation of the hemostatic system is controlled by a vast network of capillaries and venules through anticoagulant and antiinflammatory regulatory factors that operate from the endothelium( e. G. , protein C and thrombomodulin, tissue factor pathway inhibitor).

  2. Pulsed liquid microjet for intravascular injection

    Science.gov (United States)

    Palanker, Daniel V.; Fletcher, Daniel A.; Miller, Jason; Huie, Philip; Marmor, Michael; Blumenkranz, Mark S.

    2002-06-01

    Occlusions of the retinal veins and arteries are associated with common diseases such as hypertension and arteriosclerosis and usually cause severe and irreversible loss of vision. Treatments for these vascular diseases have been unsatisfactory to date in part because of the difficulty of delivering thrombolytic drugs locally within the eye. In this article we describe a pulsed liquid microjet for minimally invasive intra-vascular drug delivery. The microjet is driven by a vapor bubble following an explosive evaporation of saline, produced by a microsecond-long electric discharge in front of the 25 micrometers electrode inside the micronozzle. Expansion of the transient vapor bubble produces a water jet with a diameter equal to the diameter of the nozzle, and with a velocity and duration that are controlled by the pulse energy. We found that fluid could be injected through the wall of a 60-micrometers -diameter artery in choriallantoic membrane using a 15-micrometers diameter liquid jet traveling at more than 60 m/s. Histological analysis of these arteries showed that the width of the perforation is limited to the diameter of the micronozzle, and the penetration depth of the jet is controlled by the discharge energy. The pulsed liquid microjet offers a promising technique for precise and needle-free intravascular delivery of thrombolytic drugs for localized treatment of retinal vascular occlusions.

  3. Value of intravascular ultrasound in the assessment of pulmonary vascular properties and mortality in patients with pulmonary artery hypertension associated with connective tissue diseases%血管内超声评估结缔组织病相关性肺动脉高压患者肺血管性能和病死率

    Institute of Scientific and Technical Information of China (English)

    蔡宗烨; 李剑; 孙灵跃; 杨程德; 沈节艳; 何奔

    2015-01-01

    血管性能恶化,而其中PAH-CTD患者较其他类型的PAH患者好.PAH-CTD患者与其他类型的PAH患者的生存曲线未见明显差异,而在PAH患者中肺血管远端重塑型病死率较近端重塑型高.%Objective To investigate the value of intravascular ultrasound (IVUS) on assessing pulmonary vascular properties (PVPs) and its relationship with hemodynamics,and mortality rate in patients with pulmonary arterial hypertension associated with connective tissue disease (PAH-CTD).Methods Patients (n =51) with highly suspected PAH-CTD were prospectively enrolled in our department between July 2011 and March 2014.All patients underwent right heart catheterization (RHC) and IVUS,and were divided into 3 groups:PAH-CTD (n =25),PAH due to other reasons (n =15),and non-PAH control group (n=11).Based on IVUS,PAH patients were divided into distal (n =22) and proximal (n =18) remodeling subtypes.A total of 408 pulmonary segments were detected by IVUS,and all patients were followed up to (19 ± 10) months.Results IVUS evidenced higher mean wall thickness (MWT) ((0.30 ± 0.02) mm and (0.33 ± 0.02) mm vs.(0.21 ± 0.02) rmm) and percentage of MWT (WTP) ((13.62 ± 0.59)% and (14.39 0.77)% vs.(9.57 ±0.97)%) values in PAH patients compared to control patients (all P < 0.01).Pulmonary vascular mechanical properties (PVMPs) including compliance ((8.85 ± 0.82) × 10 2-mm2/mmHg(1 mmHg =0.133 kPa) and (6.28 ± 0.65) × 10--2 mm2/mmHg vs.(41.59 ± 5.02) × 10-2 mm2-/mmHg,all P < 0.01),distensibility ((0.83 ± 0.09)%/mmHg and (0.55 ±0.06)%/mmHg vs.(3.16 ±0.38) %/mmHg,all P <0.01),elastic modulus ((169.25 ± 15.10) mmHg and (253.00 ± 22.11) mmHg vs.(43.78 ± 4.27) mmHg,all P < 0.01) and stiffness index 3 (4.19 ±0.41 and 5.18 ±0.34 vs.2.39 ±0.27,P <0.05 or 0.01) in PAH groups were all significantly worse than in control group (all P <0.01).An inverse exponential association was found between PVMPs and hemodynamics with R2 ranging from 0.544 to 0

  4. Cook Inlet and Kenai Peninsula, Alaska ESI: VOLCANOS (Volcano Points)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains the locations of volcanos in Cook Inlet and Kenai Peninsula, Alaska. Vector points in the data set represent the location of the volcanos....

  5. Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

    Science.gov (United States)

    Bui, Nhat Quang; Hlaing, Kyu Kyu; Nguyen, Van Phuc; Nguyen, Trung Hau; Oh, Yun-Ok; Fan, Xiao Feng; Lee, Yong Wook; Nam, Seung Yun; Kang, Hyun Wook; Oh, Junghwan

    2015-10-01

    Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Volcanoes: Coming Up from Under.

    Science.gov (United States)

    Science and Children, 1980

    1980-01-01

    Provides specific information about the eruption of Mt. St. Helens in March 1980. Also discusses how volcanoes are formed and how they are monitored. Words associated with volcanoes are listed and defined. (CS)

  7. Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography

    Science.gov (United States)

    Ma, Jianguo; Martin, K. Heath; Li, Yang; Dayton, Paul A.; Shung, K. Kirk; Zhou, Qifa; Jiang, Xiaoning

    2015-01-01

    Imaging of coronary vasa vasorum may lead to assessment of the vulnerable plaque development in diagnosis of atherosclerosis diseases. Dual frequency transducers capable of detection of microbubble super-harmonics have shown promise as a new contrast-enhanced intravascular ultrasound (CE-IVUS) platform with the capability of vasa vasorum imaging. Contrast-to-tissue ratio (CTR) in CE-IVUS imaging can be closely associated with the low frequency transmitter performance. In this paper, transducer designs encompassing different transducer layouts, transmitting frequencies, and transducer materials are compared for optimization of imaging performance. In the layout selection, the stacked configuration showed superior super-harmonic imaging compared with the interleaved configuration. In the transmitter frequency selection, a decrease in frequency from 6.5 MHz to 5 MHz resulted in an increase of CTR from 15 dB to 22 dB when receiving frequency was kept constant at 30 MHz. In the material selection, the dual frequency transducer with the lead magnesium niobate-lead titanate (PMN-PT) 1-3 composite transmitter yielded higher axial resolution compared to single crystal transmitters (70 μm compared to 150 μm pulse length). These comparisons provide guidelines for design of intravascular acoustic angiography transducers. PMID:25856384

  8. A Broadband Polyvinylidene Difluoride-Based Hydrophone with Integrated Readout Circuit for Intravascular Photoacoustic Imaging.

    Science.gov (United States)

    Daeichin, Verya; Chen, Chao; Ding, Qing; Wu, Min; Beurskens, Robert; Springeling, Geert; Noothout, Emile; Verweij, Martin D; van Dongen, Koen W A; Bosch, Johan G; van der Steen, Antonius F W; de Jong, Nico; Pertijs, Michiel; van Soest, Gijs

    2016-05-01

    Intravascular photoacoustic (IVPA) imaging can visualize the coronary atherosclerotic plaque composition on the basis of the optical absorption contrast. Most of the photoacoustic (PA) energy of human coronary plaque lipids was found to lie in the frequency band between 2 and 15 MHz requiring a very broadband transducer, especially if a combination with intravascular ultrasound is desired. We have developed a broadband polyvinylidene difluoride (PVDF) transducer (0.6 × 0.6 mm, 52 μm thick) with integrated electronics to match the low capacitance of such a small polyvinylidene difluoride element (<5 pF/mm(2)) with the high capacitive load of the long cable (∼100 pF/m). The new readout circuit provides an output voltage with a sensitivity of about 3.8 μV/Pa at 2.25 MHz. Its response is flat within 10 dB in the range 2 to 15 MHz. The root mean square (rms) output noise level is 259 μV over the entire bandwidth (1-20 MHz), resulting in a minimum detectable pressure of 30 Pa at 2.25 MHz.

  9. Lipid detection by intravascular photoacoustic imaging with flexible catheter at 20 fps (Conference Presentation)

    Science.gov (United States)

    Wu, Min; Daeichin, Verya; Springeling, Geert; van der Steen, Antonius F. W.; van Soest, Gijs

    2016-02-01

    Intravascular Photoacoustic (IVPA) imaging is a promising new technology to assess lipid content of coronary atherosclerotic plaque, an important determinant of the risk associated with the plaque triggering a heart attack. Clinical translation of IVPA imaging requires real-time image acquisition, which has been a technological challenge. In this work, we demonstrate a high-speed, dual-wavelength IVPA imaging system at 1.7 µm wavelength, operating with a flexible catheter of 1.2 mm outer diameter (including outer sheath). The catheter was custom designed and fabricated, and used a 40 MHz transducer for intravascular ultrasound (IVUS) and IVPA imaging. The optical excitation is provided by a dual OPO system, pumped by CW diode-pumped Q-switched Nd:YAG lasers, with a repetition rate of 5 kHz. Each OPO can be tuned to a custom wavelength between 1690 and 1750 nm; two wavelengths only are needed to discriminate between plaque lipids and adipose tissue. The pulse energy is about 80 µJ. We tested the imaging performance of the presented system in a polyvinyl-alcohol (PVA) vessel mimicking phantom and human coronary arteries ex vivo. IVPA identified lipid deposits inside atherosclerotic plaque, while IVUS showed tissue structure. We demonstrated IVPA imaging at a speed of 20 frames per second, with 250 A-scans per frame. This is significantly faster than previous IVPA imaging systems, and will enable the translation of IVPA imaging into clinical practice.

  10. Organizational changes at Earthquakes & Volcanoes

    Science.gov (United States)

    Gordon, David W.

    1992-01-01

    Primary responsibility for the preparation of Earthquakes & Volcanoes within the Geological Survey has shifted from the Office of Scientific Publications to the Office of Earthquakes, Volcanoes, and Engineering (OEVE). As a consequence of this reorganization, Henry Spall has stepepd down as Science Editor for Earthquakes & Volcanoes(E&V).

  11. [Disseminated intravascular coagulation: clinical and biological diagnosis].

    Science.gov (United States)

    Touaoussa, Aziz; El Youssi, Hind; El Hassani, Imane; Hanouf, Daham; El Bergui, Imane; Zoulati, Ghizlane; Amrani Hassani, Moncef

    2015-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by the systemic activation of blood coagulation. Its pathophysiological mechanisms are complex and dependent on the underlying pathology, making the clinical and biological expression of quite variable DIC. Among the various biological parameters disrupted, most are not specific, and none of them allows in itself to make the diagnosis. All this does not facilitate the task of the practitioner for diagnosis of overt DIC, much less that of the non-overt DIC, early stage whose treatment would improve the prognosis. These considerations have led to develop scores, combining several parameters depending on their availability in daily practice, as well as their diagnostic relevance. Of all the scores, the ISTH (International society of thrombosis and hemostasis) remains the most used.

  12. Quinine-Induced Disseminated Intravascular Coagulation

    Directory of Open Access Journals (Sweden)

    Firas Abed

    2016-01-01

    Full Text Available Every drug comes with some side effect. It is the benefit/risk ratio that determines the medical use of the drug. Quinine, a known antimalarial drug, has been used for nocturnal leg cramps since the 1930s; it is associated with severe life-threatening hematological and cardiovascular side effects. Disseminated intravascular coagulation (DIC, albeit rare, is a known coagulopathy associated with Quinine. It is imperative to inquire about the Quinine intake in medication history in patients with coagulopathy, as most patients still consider it a harmless home remedy for nocturnal leg cramps. In this report, we present a case of coagulopathy in a middle-aged woman, who gave a history of taking Quinine for nocturnal leg cramps, as her home remedy. Early identification of the offending agent led to the diagnosis, prompt discontinuation of the medication, and complete recovery and prevented the future possibility of recurrence.

  13. Electromagnetic actuation methods for intravascular locomotive microrobot.

    Science.gov (United States)

    Cha, Kyoungrae; Jeong, Semi; Choi, Jongho; Qin, Lulu; Li, Jie; Park, Jongoh; Park, Sukho

    2010-01-01

    Heart diseases such as angina pectoris and myocardial infarction have been becoming the leading causes of death all over the world in recent years. The pharmacotherapy and the surgical operations have been executed for treating heart problems. The percutaneous coronary intervention (PCI) with catheter is frequently used for the treatment of coronary artery diseases, but the treatment of chronic total occlusion (CTO) is very difficult and challenging operation, since there is no efficient alternative therapy until now. For this reason, the microrobot to improve the intravascular treatment is one of the growing research areas. In this paper, various electromagnetic actuation (EMA) systems to supply driving power for the microrobot were proposed. The performance of the locomotion of microrobot in the 2D and 3D space were validated with in-vitro experiments and also the in-vivo tests were performed for demonstrating the movement of microrobot in the living rabbit.

  14. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... as detailed as with the transrectal probe. An MRI of the pelvis may be obtained as an ... Benign Prostatic Hyperplasia (BPH) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning may be able to give a ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer into the body. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the ... time to the procedure. If a Doppler ultrasound study is performed, you may actually hear pulse-like ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? In women, a pelvic ultrasound is most ... child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal , endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... 3-D ultrasound or sonohysterography for patients with infertility. In this setting, three-dimensional ultrasound provides information ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... 20 minutes. top of page What will I experience during and after the procedure? Ultrasound exams in ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Most ultrasound scanning is noninvasive (no needles or injections). Occasionally, an ultrasound exam may be temporarily uncomfortable, ... the following text box: Comment: E-mail: Area code: Phone no: Thank you! Images × Image Gallery Radiologist ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. Three- ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... For most ultrasound exams, you will be positioned lying face-up on an examination table that can ... ovaries. Transvaginal ultrasound is usually performed with you lying on your back, possibly with your feet in ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  14. Endoscopic ultrasound

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007646.htm Endoscopic ultrasound To use the sharing features on this page, please enable JavaScript. Endoscopic ultrasound is a type of imaging test. It is ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... chest. To obtain high-quality images, an ultrasound transducer – a plastic cylinder about the size of a ... or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on the ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... time to the procedure. If a Doppler ultrasound study is performed, you may actually hear pulse-like ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ... system disorders in both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and fluid aspiration. Pelvic ultrasound can help to identify and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? In women, a pelvic ultrasound is most ... child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... a regular ultrasound imaging probe on the perineal skin of the patient, between the legs and behind ...

  7. Disseminated intravascular coagulation in burn injury.

    Science.gov (United States)

    Lippi, Giuseppe; Ippolito, Luigi; Cervellin, Gianfranco

    2010-06-01

    Disseminated intravascular coagulation (DIC) is a complex and multifaceted disorder characterized by the activation of coagulation and fibrinolytic pathways, consumption of coagulation factors, and depletion of coagulation regulatory proteins. The introduction into the circulation of cellular debris characterized by strong thromboplastic activity due to tissue factor exposition or release (in or from burned tissues), which can thereby activate extrinsic pathway of coagulation system and trigger massive thrombin generation when present in sufficient concentration, represents the most plausible biological explanation to support the development of intravascular coagulation in patients with burn injury. Severe burns left untreated might also lead to an immunological and inflammatory response (activation of the complement cascade), which can amplify fibrinolysis and blood clotting. Overall, the real prevalence of DIC in patients with burns is as yet unclear. Postmortem, retrospective, and even longitudinal investigations are in fact biased by several factors, such as the objective difficulty to establish whether DIC might have occurred as a primary complication of burns or rather as a consequence of other superimposed pathologies (e.g., sepsis, multiple organ failure), the different diagnostic criteria for assessing DIC, and the heterogeneity of the patient samples studied. Nevertheless, the current scientific evidence is consistent with the hypothesis that biochemical changes suggestive for DIC (hypercoagulability, hypo- and hyperfibrinolysis) are commonplace in patients with burn trauma, and their severity increases exponentially with the severity of injury. Overt DIC seems to occur especially in critically ill burn patients or in those with severe burns (up to third degree) and large involvement of body surface area, in whom an appropriate therapy might be effective to prevent the otherwise fulminant course. Although early prophylaxis with antithrombin concentrates

  8. Hawaii's volcanoes revealed

    Science.gov (United States)

    Eakins, Barry W.; Robinson, Joel E.; Kanamatsu, Toshiya; Naka, Jiro; Smith, John R.; Takahashi, Eiichi; Clague, David A.

    2003-01-01

    Hawaiian volcanoes typically evolve in four stages as volcanism waxes and wanes: (1) early alkalic, when volcanism originates on the deep sea floor; (2) shield, when roughly 95 percent of a volcano's volume is emplaced; (3) post-shield alkalic, when small-volume eruptions build scattered cones that thinly cap the shield-stage lavas; and (4) rejuvenated, when lavas of distinct chemistry erupt following a lengthy period of erosion and volcanic quiescence. During the early alkalic and shield stages, two or more elongate rift zones may develop as flanks of the volcano separate. Mantle-derived magma rises through a vertical conduit and is temporarily stored in a shallow summit reservoir from which magma may erupt within the summit region or be injected laterally into the rift zones. The ongoing activity at Kilauea's Pu?u ?O?o cone that began in January 1983 is one such rift-zone eruption. The rift zones commonly extend deep underwater, producing submarine eruptions of bulbous pillow lava. Once a volcano has grown above sea level, subaerial eruptions produce lava flows of jagged, clinkery ?a?a or smooth, ropy pahoehoe. If the flows reach the ocean they are rapidly quenched by seawater and shatter, producing a steep blanket of unstable volcanic sediment that mantles the upper submarine slopes. Above sea level then, the volcanoes develop the classic shield profile of gentle lava-flow slopes, whereas below sea level slopes are substantially steeper. While the volcanoes grow rapidly during the shield stage, they may also collapse catastrophically, generating giant landslides and tsunami, or fail more gradually, forming slumps. Deformation and seismicity along Kilauea's south flank indicate that slumping is occurring there today. Loading of the underlying Pacific Plate by the growing volcanic edifices causes subsidence, forming deep basins at the base of the volcanoes. Once volcanism wanes and lava flows no longer reach the ocean, the volcano continues to submerge, while

  9. Intravascular photoacoustic detection of vulnerable plaque based on constituent selected imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jian; Xing Da, E-mail: xingda@scnu.edu.cn [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China)

    2011-01-01

    Atherosclerosis, a disease of the large arteries, is the primary cause of heart disease and stroke. Over decades, atherosclerosis is characterized by thickening of the walls of the arteries, only advanced atherosclerotic disease could be observed. Photoacoustic imaging is a hybrid imaging technique that combines the advantages of high spatial resolution of ultrasound with contrast of optical absorption. In this paper, we present an intravascular photoacoustic (IVPA) imaging system to characterize vulnerable plaques by using the optical absorption contrast between different constituents. Epidemiological studies have revealed several important plaque constituents associated with early atherosclerosis, such as macrophage, cholesterol, lipid, calcification, and so on. We chose a section of lipid rich atherosclerosis artery and a section of normal artery as the phantom. Two IVPA images of them are given to show the difference between sick and normal. As a new method of detecting vulnerable plaque, IVPA constituents imaging will provide more details for diagnosis that offer an enticing prospect in early detecting of atherosclerosis.

  10. Real-time volumetric lipid imaging in vivo by intravascular photoacoustics at 20 frames per second

    Science.gov (United States)

    Wu, Min; Springeling, Geert; Lovrak, Matija; Mastik, Frits; Iskander-Rizk, Sophinese; Wang, Tianshi; van Beusekom, Heleen M. M.; van der Steen, A. F. W.; Van Soest, Gijs

    2017-01-01

    Lipid deposition can be assessed with combined intravascular photoacoustic/ultrasound (IVPA/US) imaging. To date, the clinical translation of IVPA/US imaging has been stalled by a low imaging speed and catheter complexity. In this paper, we demonstrate imaging of lipid targets in swine coronary arteries in vivo, at a clinically useful frame rate of 20 s−1. We confirmed image contrast for atherosclerotic plaque in human samples ex vivo. The system is on a mobile platform and provides real-time data visualization during acquisition. We achieved an IVPA signal-to-noise ratio of 20 dB. These data show that clinical translation of IVPA is possible in principle. PMID:28270995

  11. Carotid Ultrasound

    Science.gov (United States)

    ... this page from the NHLBI on Twitter. Carotid Ultrasound Also known as carotid duplex. Carotid ultrasound is a painless imaging test that uses high- ... of your carotid arteries. This test uses an ultrasound machine, which includes a computer, a screen, and ...

  12. Santa Maria Volcano, Guatemala

    Science.gov (United States)

    2002-01-01

    The eruption of Santa Maria volcano in 1902 was one of the largest eruptions of the 20th century, forming a large crater on the mountain's southwest flank. Since 1922, a lava-dome complex, Santiaguito, has been forming in the 1902 crater. Growth of the dome has produced pyroclastic flows as recently as the 2001-they can be identified in this image. The city of Quezaltenango (approximately 90,000 people in 1989) sits below the 3772 m summit. The volcano is considered dangerous because of the possibility of a dome collapse such as one that occurred in 1929, which killed about 5000 people. A second hazard results from the flow of volcanic debris into rivers south of Santiaguito, which can lead to catastrophic flooding and mud flows. More information on this volcano can be found at web sites maintained by the Smithsonian Institution, Volcano World, and Michigan Tech University. ISS004-ESC-7999 was taken 17 February 2002 from the International Space Station using a digital camera. The image is provided by the Earth Sciences and Image Analysis Laboratory at Johnson Space Center. Searching and viewing of additional images taken by astronauts and cosmonauts is available at the NASA-JSC Gateway to

  13. Anatomy of a volcano

    NARCIS (Netherlands)

    Wassink, J.

    2011-01-01

    The Icelandic volcano Eyjafjallajökull caused major disruption in European airspace last year. According to his co-author, Freysteinn Sigmundsson, the reconstruction published in Nature six months later by aerospace engineering researcher, Dr Andy Hooper, opens up a new direction in volcanology. “W

  14. Catalogue of Icelandic Volcanoes

    Science.gov (United States)

    Ilyinskaya, Evgenia; Larsen, Gudrun; Gudmundsson, Magnus T.; Vogfjord, Kristin; Pagneux, Emmanuel; Oddsson, Bjorn; Barsotti, Sara; Karlsdottir, Sigrun

    2016-04-01

    The Catalogue of Icelandic Volcanoes is a newly developed open-access web resource in English intended to serve as an official source of information about active volcanoes in Iceland and their characteristics. The Catalogue forms a part of an integrated volcanic risk assessment project in Iceland GOSVÁ (commenced in 2012), as well as being part of the effort of FUTUREVOLC (2012-2016) on establishing an Icelandic volcano supersite. Volcanic activity in Iceland occurs on volcanic systems that usually comprise a central volcano and fissure swarm. Over 30 systems have been active during the Holocene (the time since the end of the last glaciation - approximately the last 11,500 years). In the last 50 years, over 20 eruptions have occurred in Iceland displaying very varied activity in terms of eruption styles, eruptive environments, eruptive products and the distribution lava and tephra. Although basaltic eruptions are most common, the majority of eruptions are explosive, not the least due to magma-water interaction in ice-covered volcanoes. Extensive research has taken place on Icelandic volcanism, and the results reported in numerous scientific papers and other publications. In 2010, the International Civil Aviation Organisation (ICAO) funded a 3 year project to collate the current state of knowledge and create a comprehensive catalogue readily available to decision makers, stakeholders and the general public. The work on the Catalogue began in 2011, and was then further supported by the Icelandic government and the EU through the FP7 project FUTUREVOLC. The Catalogue of Icelandic Volcanoes is a collaboration of the Icelandic Meteorological Office (the state volcano observatory), the Institute of Earth Sciences at the University of Iceland, and the Civil Protection Department of the National Commissioner of the Iceland Police, with contributions from a large number of specialists in Iceland and elsewhere. The Catalogue is built up of chapters with texts and various

  15. Imminent Cardiac Risk Assessment via Optical Intravascular Biochemical Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wetzel, D.; Wetzel, L; Wetzel, M; Lodder, R

    2009-01-01

    still the first line of defense. However, with the fidelity of 64-slice CT imaging, this technique has recently become an option when the patient presents with symptoms of reduced arterial flow. Single photon emission computerized tomography (SPECT) treadmill exercise testing is a standard non-invasive test for decreased perfusion of heart muscle, but is time consuming and not suited for emergent evaluation. Once the invasive clinical option of catherization is chosen, this provides the opportunity for intravascular ultrasound (IVUS) imaging. As the probe is pulled through the artery, the diameter at different parts is measurable, and monochrome contrast in the constricted area reveals the presence of tissue with a different ultrasonic response. Also, via an optical catheter with a fiber-optic conductor, the possibly of spectroscopic analysis of arterial walls is now a reality. In this case, the optical transducer is coupled to a near-infrared spectrometer. Revealing the arterial chemical health means that plaque vulnerability and imminent risk could be assessed by the physician. The classical emergency use of catherization involves a contrast agent and dynamic X-ray imaging to locate the constriction, determine its severity, and possibly perform angioplasty, and stent placement.

  16. Intravascular probe for detection of vulnerable plaque

    Science.gov (United States)

    Patt, Bradley E.; Iwanczyk, Jan S.; MacDonald, Lawrence R.; Yamaguchi, Yuko; Tull, Carolyn R.; Janecek, Martin; Hoffman, Edward J.; Strauss, H. William; Tsugita, Ross; Ghazarossian, Vartan

    2001-12-01

    Coronary angiography is unable to define the status of the atheroma, and only measures the luminal dimensions of the blood vessel, without providing information about plaque content. Up to 70% of heart attacks are caused by minimally obstructive vulnerable plaques, which are too small to be detected adequately by angiography. We have developed an intravascular imaging detector to identify vulnerable coronary artery plaques. The detector works by sensing beta or conversion electron radiotracer emissions from plaque-binding radiotracers. The device overcomes the technical constraints of size, sensitivity and conformance to the intravascular environment. The detector at the distal end of the catheter uses six 7mm long by 0.5mm diameter scintillation fibers coupled to 1.5m long plastic fibers. The fibers are offset from each other longitudinally by 6mm and arranged spirally around a guide wire in the catheter. At the proximal end of the catheter the optical fibers are coupled to an interface box with a snap on connector. The interface box contains a position sensitive photomultiplier tube (PSPMT) to decode the individual fibers. The whole detector assembly fits into an 8-French (2.7 mm in diameter) catheter. The PSPMT image is further decoded with software to give a linear image, the total instantaneous count rate and an audio output whose tone corresponds to the count rate. The device was tested with F-18 and Tl-204 sources. Spectrometric response, spatial resolution, sensitivity and beta to background ratio were measured. System resolution is 6 mm and the sensitivity is >500 cps / micrometers Ci when the source is 1 mm from the detector. The beta to background ratio was 11.2 for F-18 measured on a single fiber. The current device will lead to a system allowing imaging of labeled vulnerable plaque in coronary arteries. This type of signature is expected to enable targeted and cost effective therapies to prevent acute coronary artery diseases such as: unstable angina

  17. Intravascular Large B-Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Maria S. Khan MD, FACP

    2014-03-01

    Full Text Available Case Presentation. A 69-year-old Hispanic male, with a past history of diabetes and coronary disease, was admitted for fever, diarrhea, and confusion of 4 weeks duration. Physical examination showed a disoriented patient with multiple ecchymoses, possible ascites, and bilateral scrotal swelling. Hemoglobin was 6.7, prothrombin time (PT 21.4 seconds with international normalized ratio 2.1, partial thromboplastin time (PTT 55.6 seconds, fibrin split 10 µg/L, and lactate dehydrogenase (LDH 1231 IU/L. Except for a positive DNA test for Epstein–Barr virus (EBV infection, extensive diagnostic workup for infections, malignancy, or a neurological cause was negative. Mixing studies revealed a nonspecific inhibitor of PT and PTT but Factor VIII levels were normal. The patient was empirically treated with antibiotics but developed hypotension and died on day 27 of admission. At autopsy, patient was found to have intravascular diffuse large B-cell lymphoma involving skin, testes, lung, and muscles. The malignant cells were positive for CD20, CD791, Mum-1, and Pax-5 and negative for CD3, CD5, CD10, CD30, and Bcl-6. The malignant cells were 100% positive for Ki-67. Discussion. Intravascular large cell B-cell lymphoma (IVLBCL is rare form of diffuse large B-cell lymphoma and tends to proliferate within small blood vessels, particularly capillaries and postcapillary venules. The cause of its affinity for vascular bed remains unknown. In many reports, IVLBCL was associated with HIV, HHV8, and EBV infections. The fact that our case showed evidence of EBV infection lends support to the association of this diagnosis to viral illness. The available literature on this subject is scant, and in many cases, the diagnosis was made only at autopsy. The typical presentation of this disorder is with B symptoms, progressive neurologic deficits, and skin findings. Bone marrow, spleen, and liver are involved in a minority of patients. Nearly all patients have elevated LDH

  18. Dynamic contrast enhanced ultrasound for therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, John M. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Williams, Ross [Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Tremblay-Darveau, Charles; Sheeran, Paul S. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Milot, Laurent [Department of Medical Imaging, University of Toronto, Toronto, ON (Canada); Bjarnason, Georg A. [Department of Medical Oncology, University of Toronto, and Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); Burns, Peter N., E-mail: burns@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON (Canada)

    2015-09-15

    Quantitative imaging is a crucial component of the assessment of therapies that target the vasculature of angiogenic or inflamed tissue. Dynamic contrast-enhanced ultrasound (DCE-US) using microbubble contrast offers the advantages of being sensitive to perfusion, non-invasive, cost effective and well suited to repeated use at the bedside. Uniquely, it employs an agent that is truly intravascular. This papers reviews the principles and methodology of DCE-US, especially as applied to anti-angiogenic cancer therapies. Reproducibility is an important attribute of such a monitoring method: results are discussed. More recent technical advances in parametric and 3D DCE-US imaging are also summarised and illustrated.

  19. Catalogue of Icelandic volcanoes

    Science.gov (United States)

    Ilyinskaya, Evgenia; Larsen, Gudrun; Vogfjörd, Kristin; Tumi Gudmundsson, Magnus; Jonsson, Trausti; Oddsson, Björn; Reynisson, Vidir; Barsotti, Sara; Karlsdottir, Sigrun

    2015-04-01

    Volcanic activity in Iceland occurs on volcanic systems that usually comprise a central volcano and fissure swarm. Over 30 systems have been active during the Holocene. In the last 100 years, over 30 eruptions have occurred displaying very varied activity in terms of eruption styles, eruptive environments, eruptive products and their distribution. Although basaltic eruptions are most common, the majority of eruptions are explosive, not the least due to magma-water interaction in ice-covered volcanoes. Extensive research has taken place on Icelandic volcanism, and the results reported in scientific papers and other publications. In 2010, the International Civil Aviation Organisation funded a 3 year project to collate the current state of knowledge and create a comprehensive catalogue readily available to decision makers, stakeholders and the general public. The work on the Catalogue began in 2011, and was then further supported by the Icelandic government and the EU. The Catalogue forms a part of an integrated volcanic risk assessment project in Iceland (commenced in 2012), and the EU FP7 project FUTUREVOLC (2012-2016), establishing an Icelandic volcano Supersite. The Catalogue is a collaborative effort between the Icelandic Meteorological Office (the state volcano observatory), the Institute of Earth Sciences at the University of Iceland, and the Icelandic Civil Protection, with contributions from a large number of specialists in Iceland and elsewhere. The catalogue is scheduled for opening in the first half of 2015 and once completed, it will be an official publication intended to serve as an accurate and up to date source of information about active volcanoes in Iceland and their characteristics. The Catalogue is an open web resource in English and is composed of individual chapters on each of the volcanic systems. The chapters include information on the geology and structure of the volcano; the eruption history, pattern and products; the known precursory signals

  20. Volcano-hazard zonation for San Vicente volcano, El Salvador

    Science.gov (United States)

    Major, J.J.; Schilling, S.P.; Pullinger, C.R.; Escobar, C.D.; Howell, M.M.

    2001-01-01

    San Vicente volcano, also known as Chichontepec, is one of many volcanoes along the volcanic arc in El Salvador. This composite volcano, located about 50 kilometers east of the capital city San Salvador, has a volume of about 130 cubic kilometers, rises to an altitude of about 2180 meters, and towers above major communities such as San Vicente, Tepetitan, Guadalupe, Zacatecoluca, and Tecoluca. In addition to the larger communities that surround the volcano, several smaller communities and coffee plantations are located on or around the flanks of the volcano, and major transportation routes are located near the lowermost southern and eastern flanks of the volcano. The population density and proximity around San Vicente volcano, as well as the proximity of major transportation routes, increase the risk that even small landslides or eruptions, likely to occur again, can have serious societal consequences. The eruptive history of San Vicente volcano is not well known, and there is no definitive record of historical eruptive activity. The last significant eruption occurred more than 1700 years ago, and perhaps long before permanent human habitation of the area. Nevertheless, this volcano has a very long history of repeated, and sometimes violent, eruptions, and at least once a large section of the volcano collapsed in a massive landslide. The oldest rocks associated with a volcanic center at San Vicente are more than 2 million years old. The volcano is composed of remnants of multiple eruptive centers that have migrated roughly eastward with time. Future eruptions of this volcano will pose substantial risk to surrounding communities.

  1. Laboratory testing in disseminated intravascular coagulation.

    Science.gov (United States)

    Favaloro, Emmanuel J

    2010-06-01

    The diagnosis of disseminated intravascular coagulation (DIC) relies on clinical signs and symptoms, identification of the underlying disease, the results of laboratory testing, and differentiation from other pathologies. The clinical features mainly depend on the underlying cause of the DIC. The laboratory diagnosis of DIC uses a combination of tests because no single test result alone can firmly establish or rule out the diagnosis. Global tests of hemostasis may initially provide evidence of coagulation activation and later in the process provide evidence of consumption of coagulation factors, but their individual diagnostic efficiency is limited. Fibrinolytic markers, in particular D-dimer, are reflective of activation of both coagulation and fibrinolysis, so that a normal finding can be useful for ruling-out DIC. Decreased levels of the natural anticoagulants (in particular, antithrombin and protein C) are frequently observed in patients with DIC, but their measurement is not normally incorporated into standard diagnostic algorithms. New tests are being explored for utility in DIC, and some additional tests may be useful on a case-by-case basis, depending on the proposed cause of the DIC or their local availability. For example, clot waveform analysis is useful but currently limited to a single instrument. Also, procalcitonin is an inflammatory biomarker that may be useful within the context of septic DIC, and activated factor X clotting time is an emerging test of procoagulant phospholipids that also seems to hold promise in DIC.

  2. Primary intravascular synovial sarcoma: case report.

    Science.gov (United States)

    Tuncer, Osman Nuri; Erbasan, Ozan; Golbasi, Ilhan

    2012-10-01

    Synovial sarcoma (SS), a mesenchymal spindle cell tumor, displays variable epithelial differentiation, including glandular formation, and features a specific chromosomal translocation, t(X;18)(p11;q11). SS accounts for 5% to 10% of soft-tissue sarcomas. These tumors occur mostly in the joints, especially near the knee, but they also occur in other locations. Primary intravascular SS (IVSS) are extremely rare; only 6 well-documented cases have been reported in the English literature. We describe a new case of primary IVSS of the superior vena cava (SVC) in a 16-year-old boy. A transthoracic echocardiogram confirmed a large (4.8 × 4.6 cm) circumscribed mass filling the right atrium, as well as a moderate pericardial effusion. The mass extended from the SVC to the tricuspid valve but did not prevent valve coaptation. Surgery via a transatrial approach revealed a huge mass (8 to 12 cm) attached to the SVC via a 5-mm pedicle. The tumor was excised, and the patient experienced an uneventful postoperative course. Fluorescence in situ hybridization analysis revealed the presence of the SS-specific translocation.

  3. Toward a Continuous Intravascular Glucose Monitoring System

    Directory of Open Access Journals (Sweden)

    Pedro Irazoqui

    2010-12-01

    Full Text Available Proof-of-concept studies that display the potential of using a glucose-sensitive hydrogel as a continuous glucose sensor are presented. The swelling ratio, porosity, and diffusivity of the hydrogel increased with glucose concentration. In glucose solutions of 50, 100, 200, and 300 mg/dL, the hydrogel swelling ratios were 4.9, 12.3, 15.9, and 21.7, respectively, and the swelling was reversible. The impedance across the hydrogel depended solely on the thickness and had an average increase of 47 W/mm. The hydrogels exposed to a hyperglycemic solution were more porous than the hydrogels exposed to a normal glycemic solution. The diffusivity of 390 Da MW fluorescein isothiocyanate in hydrogels exposed to normal and hyperglycemic solutions was examined using fluorescence recovery after photobleaching and was found to be 9.3 × 10−14 and 41.4 × 10−14 m2/s, respectively, compared to 6.2 × 10−10 m2/s in glucose solution. There was no significant difference between the permeability of hydrogels in normal and hyperglycemic glucose solutions with averages being 5.26 × 10−17 m2 and 5.80 × 10−17 m2, respectively, which resembles 2–4% agarose gels. A prototype design is presented for continuous intravascular glucose monitoring by attaching a glucose sensor to an FDA-approved stent.

  4. Thyroid ultrasound

    OpenAIRE

    Vikas Chaudhary; Shahina Bano

    2013-01-01

    Thyroid ultrasonography has established itself as a popular and useful tool in the evaluation and management of thyroid disorders. Advanced ultrasound techniques in thyroid imaging have not only fascinated the radiologists but also attracted the surgeons and endocrinologists who are using these techniques in their daily clinical and operative practice. This review provides an overview of indications for ultrasound in various thyroid diseases, describes characteristic ultrasound findings in th...

  5. Ultrasound physics.

    Science.gov (United States)

    Shriki, Jesse

    2014-01-01

    Bedside ultrasound has become an important modality for obtaining critical information in the acute care of patients. It is important to understand the physics of ultrasound in order to perform and interpret images at the bedside. The physics of both continuous wave and pulsed wave sound underlies diagnostic ultrasound. The instrumentation, including transducers and image processing, is important in the acquisition of appropriate sonographic images. Understanding how these concepts interplay with each other enables practitioners to obtain the best possible images.

  6. Geology of Kilauea volcano

    Energy Technology Data Exchange (ETDEWEB)

    Moore, R.B. (Geological Survey, Denver, CO (United States). Federal Center); Trusdell, F.A. (Geological Survey, Hawaii National Park, HI (United States). Hawaiian Volcano Observatory)

    1993-08-01

    This paper summarizes studies of the structure, stratigraphy, petrology, drill holes, eruption frequency, and volcanic and seismic hazards of Kilauea volcano. All the volcano is discussed, but the focus is on its lower east rift zone (LERZ) because active exploration for geothermal energy is concentrated in that area. Kilauea probably has several separate hydrothermal-convection systems that develop in response to the dynamic behavior of the volcano and the influx of abundant meteoric water. Important features of some of these hydrothermal-convection systems are known through studies of surface geology and drill holes. Observations of eruptions during the past two centuries, detailed geologic mapping, radiocarbon dating, and paleomagnetic secular-variation studies indicate that Kilauea has erupted frequently from its summit and two radial rift zones during Quaternary time. Petrologic studies have established that Kilauea erupts only tholeiitic basalt. Extensive ash deposits at Kilauea's summit and on its LERZ record locally violent, but temporary, disruptions of local hydrothermal-convection systems during the interaction of water or steam with magma. Recent drill holes on the LERZ provide data on the temperatures of the hydrothermal-convection systems, intensity of dike intrusion, porosity and permeability, and an increasing amount of hydrothermal alteration with depth. The prehistoric and historic record of volcanic and seismic activity indicates that magma will continue to be supplied to deep and shallow reservoirs beneath Kilauea's summit and rift zones and that the volcano will be affected by eruptions and earthquakes for many thousands of years. 71 refs., 2 figs.

  7. 4D volcano gravimetry

    Science.gov (United States)

    Battaglia, Maurizio; Gottsmann, J.; Carbone, D.; Fernandez, J.

    2008-01-01

    Time-dependent gravimetric measurements can detect subsurface processes long before magma flow leads to earthquakes or other eruption precursors. The ability of gravity measurements to detect subsurface mass flow is greatly enhanced if gravity measurements are analyzed and modeled with ground-deformation data. Obtaining the maximum information from microgravity studies requires careful evaluation of the layout of network benchmarks, the gravity environmental signal, and the coupling between gravity changes and crustal deformation. When changes in the system under study are fast (hours to weeks), as in hydrothermal systems and restless volcanoes, continuous gravity observations at selected sites can help to capture many details of the dynamics of the intrusive sources. Despite the instrumental effects, mainly caused by atmospheric temperature, results from monitoring at Mt. Etna volcano show that continuous measurements are a powerful tool for monitoring and studying volcanoes.Several analytical and numerical mathematical models can beused to fit gravity and deformation data. Analytical models offer a closed-form description of the volcanic source. In principle, this allows one to readily infer the relative importance of the source parameters. In active volcanic sites such as Long Valley caldera (California, U.S.A.) and Campi Flegrei (Italy), careful use of analytical models and high-quality data sets has produced good results. However, the simplifications that make analytical models tractable might result in misleading volcanological inter-pretations, particularly when the real crust surrounding the source is far from the homogeneous/ isotropic assumption. Using numerical models allows consideration of more realistic descriptions of the sources and of the crust where they are located (e.g., vertical and lateral mechanical discontinuities, complex source geometries, and topography). Applications at Teide volcano (Tenerife) and Campi Flegrei demonstrate the

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  9. Pairing the Volcano

    CERN Document Server

    Ionica, Sorina

    2011-01-01

    Isogeny volcanoes are graphs whose vertices are elliptic curves and whose edges are $\\ell$-isogenies. Algorithms allowing to travel on these graphs were developed by Kohel in his thesis (1996) and later on, by Fouquet and Morain (2001). However, up to now, no method was known, to predict, before taking a step on the volcano, the direction of this step. Hence, in Kohel's and Fouquet-Morain algorithms, many steps are taken before choosing the right direction. In particular, ascending or horizontal isogenies are usually found using a trial-and-error approach. In this paper, we propose an alternative method that efficiently finds all points $P$ of order $\\ell$ such that the subgroup generated by $P$ is the kernel of an horizontal or an ascending isogeny. In many cases, our method is faster than previous methods. This is an extended version of a paper published in the proceedings of ANTS 2010. In addition, we treat the case of 2-isogeny volcanoes and we derive from the group structure of the curve and the pairing ...

  10. Carotid Ultrasound Imaging

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Carotid Carotid ultrasound uses sound waves to produce ... limitations of Carotid Ultrasound Imaging? What is Carotid Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  11. General Ultrasound Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures ... limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  12. Venous Ultrasound (Extremities)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Venous (Extremities) Venous ultrasound uses sound waves to ... limitations of Venous Ultrasound Imaging? What is Venous Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  13. Intravascular brachytherapy for peripheral vascular disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-09-01

    Full Text Available Scientific background: Percutaneous transluminal angioplasties (PTA through balloon dilatation with or without stenting, i.e. vessel expansion through balloons with or without of implantation of small tubes, called stents, are used in the treatment of peripheral artery occlusive disease (PAOD. The intravascular vessel irradiation, called intravascular brachytherapy, promises a reduction in the rate of repeated stenosis (rate of restenosis after PTA. Research questions: The evaluation addresses questions on medical efficacy, cost-effectiveness as well as ethic, social and legal implications in the use of brachytherapy in PAOD patients. Methods: A systematic literature search was conducted in August 2007 in the most important medical electronic databases for publications beginning from 2002. The medical evaluation included randomized controlled trials (RCT. The information synthesis was performed using meta-analysis. Health economic modeling was performed with clinical assumptions derived from the meta-analysis and economical assumptions derived from the German Diagnosis Related Groups (G-DRG-2007. Results: Medical evaluation: Twelve publications about seven RCT on brachytherapy vs. no brachytherapy were included in the medical evaluation. Two RCT showed a significant reduction in the rate of restenosis at six and/or twelve months for brachytherapy vs. no brachytherapy after successful balloon dilatation, the relative risk in the meta-analysis was 0.62 (95% CI: 0.46 to 0.84. At five years, time to recurrence of restenosis was significantly delayed after brachytherapy. One RCT showed a significant reduction in the rate of restenosis at six months for brachytherapy vs. no brachytherapy after PTA with optional stenting, the relative risk in the meta-analysis was 0.76 (95% CI: 0.61 to 0.95. One RCT observed a significantly higher rate of late thrombotic occlusions after brachytherapy in the subgroup of stented patients. A single RCT for brachytherapy

  14. 76 FR 77834 - Scientific Information Request on Intravascular Diagnostic and Imaging Medical Devices

    Science.gov (United States)

    2011-12-14

    ... Intravascular Diagnostic and Imaging Medical Devices AGENCY: Agency for Healthcare Research and Quality (AHRQ... intravascular diagnostic and imaging medical devices, including: Fractional Flow Reserve (FFR), Coronary Flow... Resonance Imaging (MRI), Elastrography, and Thermography. Scientific information is being solicited to...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate ... imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also ...

  16. Ultrasound elastography and contrast-enhanced ultrasound in infants, children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Martin, E-mail: martin.stenzel@med.uni-jena.de; Mentzel, Hans-Joachim

    2014-09-15

    Objective: To describe prerequisites, use, and safety of ultrasound elastography and contrast-enhanced ultrasound in infants, children, and adolescents. Method: This review deals with two latest developments in ultrasonography in children. The principle of strain elastography, transient elastography, and acoustic radiation force imaging is discussed, including limitations, and advantages of the different techniques in diagnosing focal and diffuse organ disease. The intravesical (contrast-enhanced voiding ultrasonography) and intravascular use of contrast-media to outline blood, and urinary flow is described, with special emphasis on indications, off-label use, and diagnostic gain. Examples of indications for performing the advanced ultrasound techniques are presented. Summary and conclusion: Latest developments in ultrasound machine engineering, and the availability of contrast-media that interact with ultrasound waves allow for assessment of tissue stiffness/elasticity properties, blood, and urinary flow. Thereby ultrasound is capable not only to depict morphology, but gives the additional information on organ, and focal lesion perfusion, and urinary flow dynamics. The information gap to other cross-sectional techniques such as magnetic resonance imaging, that make potential harmful sedation, and anaesthesia in the youngest children necessary, thereby gets closer.

  17. High-intensity focused ultrasound sonothrombolysis: the use of perfluorocarbon droplets to achieve clot lysis at reduced acoustic power.

    Science.gov (United States)

    Pajek, Daniel; Burgess, Alison; Huang, Yuexi; Hynynen, Kullervo

    2014-09-01

    The purpose of this study was to evaluate use of intravascular perfluorocarbon droplets to reduce the sonication power required to achieve clot lysis with high-intensity focused ultrasound. High-intensity focused ultrasound with droplets was initially applied to blood clots in an in vitro flow apparatus, and inertial cavitation thresholds were determined. An embolic model for ischemic stroke was used to illustrate the feasibility of this technique in vivo. Recanalization with intravascular droplets was achieved in vivo at 24 ± 5% of the sonication power without droplets. Recanalization occurred in 71% of rabbits that received 1-ms pulsed sonications during continuous intravascular droplet infusion (p = 0.041 vs controls). Preliminary experiments indicated that damage was confined to the ultrasonic focus, suggesting that tolerable treatments would be possible with a more tightly focused hemispheric array that allows the whole focus to be placed inside of the main arteries in the human brain.

  18. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous, implanted, long-term intravascular... and Personal Use Therapeutic Devices § 880.5970 Percutaneous, implanted, long-term intravascular catheter. (a) Identification. A percutaneous, implanted, long-term intravascular catheter is a device...

  19. 21 CFR 880.5965 - Subcutaneous, implanted, intravascular infusion port and catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Subcutaneous, implanted, intravascular infusion... Hospital and Personal Use Therapeutic Devices § 880.5965 Subcutaneous, implanted, intravascular infusion port and catheter. (a) Identification. A subcutaneous, implanted, intravascular infusion port...

  20. Current concepts in the management of disseminated intravascular coagulation.

    Science.gov (United States)

    Thachil, Jecko; Toh, Cheng Hock

    2012-04-01

    Disseminated Intravascular Coagulation is a clinicopathological syndrome where widespread intravascular coagulation occurs in response to an inciting process. The pathophysiology for this disorder is complex with an important role for thrombin, the central regulator of the coagulation process. Since the clinical spectrum of DIC is variable due to its dynamic nature, the laboratory diagnosis should ideally be not based on a single marker or an isolated set of results. The treatment should primary focus on the management of the underlying triggering condition with blood products used as resuscitative measures. Newer therapeutic modalities have been recently tried with success although the management of DIC still remains a major challenge.

  1. Extremely refractory Kawasaki disease with disseminated intravascular coagulation.

    Science.gov (United States)

    Koh, Young Kwon; Lee, Jae Hee; Park, Yeong Bong

    2017-07-01

    Disseminated intravascular coagulation is a rare complication of Kawasaki disease and appears in Kawasaki disease patients. We report a case of refractory Kawasaki disease complicated with disseminated intravascular coagulation and giant coronary aneurysm. A 5-month-old boy presented with Kawasaki disease with coagulopathy. Although the coagulopathy improved after fresh-frozen plasma and antithrombin-III administration, the fever persisted despite two rounds of intravenous immunoglobulin, along with intravenous methylprednisolone pulse therapy and infliximab administration. Despite all efforts to treatment, the patient had giant coronary aneurysms and died suddenly.

  2. The Present Situation on Disseminated Intravascular. Coagulation Studies

    Institute of Scientific and Technical Information of China (English)

    刘泽霖

    2001-01-01

    @@ DIC is not a clinical entity in itself. Instead, it always occurs secondary to a broad spectrum of various diseases. DIC may be defined as an acquired syndrome characterized by the activation of intravascular coagulation up to intravascular fibrin formation. Although the trigger for the activation of the coagulation system may vary depending on the underlying condition, it is usually mediated by several cytokines. Thrombin generation proceeds via the (extrinsic) tissue factor/factor Ⅶ a route and simultaneous depression of inhibitory mechanisms, such as the protein C and protein S system. In addition, impaired fibrin degradation, dur to high circulating levels of PAI-1, contributes to enhanced introvascular fibrin deposition.

  3. Italian Volcano Supersites

    Science.gov (United States)

    Puglisi, G.

    2011-12-01

    Volcanic eruptions are among the geohazards that may have a substantial economic and social impact, even at worldwide scale. Large populated regions are prone to volcanic hazards worldwide. Even local phenomena may affect largely populated areas and in some cases even megacities, producing severe economic losses. On a regional or global perspective, large volcanic eruptions may affect the climate for years with potentially huge economic impacts, but even relatively small eruptions may inject large amounts of volcanic ash in the atmosphere and severely affect air traffic over entire continents. One of main challenges of the volcanological community is to continuously monitor and understand the internal processes leading to an eruption, in order to give substantial contributions to the risk reduction. Italian active volcanoes constitute natural laboratories and ideal sites where to apply the cutting-edge volcano observation systems, implement new monitoring systems and to test and improve the most advanced models and methods for investigate the volcanic processes. That's because of the long tradition of volcanological studies resulting into long-term data sets, both in-situ and from satellite systems, among the most complete and accurate worldwide, and the large spectrum of the threatening volcanic phenomena producing high local/regional/continental risks. This contribution aims at presenting the compound monitoring systems operating on the Italian active volcanoes, the main improvements achieved during the recent studies direct toward volcanic hazard forecast and risk reductions and the guidelines for a wide coordinated project aimed at applying the ideas of the GEO Supersites Initiative at Mt. Etna and Campi Flegrei / Vesuvius areas.

  4. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... sickle cell disease. It is also used to measure conditions affecting blood flow to and within the brain, such as: Stenosis : ... saved. Doppler ultrasound, a special application of ultrasound, measures ... represent the flow of blood through the blood vessels. top of ...

  5. Ruiz Volcano: Preliminary report

    Science.gov (United States)

    Ruiz Volcano, Colombia (4.88°N, 75.32°W). All times are local (= GMT -5 hours).An explosive eruption on November 13, 1985, melted ice and snow in the summit area, generating lahars that flowed tens of kilometers down flank river valleys, killing more than 20,000 people. This is history's fourth largest single-eruption death toll, behind only Tambora in 1815 (92,000), Krakatau in 1883 (36,000), and Mount Pelée in May 1902 (28,000). The following briefly summarizes the very preliminary and inevitably conflicting information that had been received by press time.

  6. Preliminary volcano-hazard assessment for Iliamna Volcano, Alaska

    Science.gov (United States)

    Waythomas, Christopher F.; Miller, Thomas P.

    1999-01-01

    Iliamna Volcano is a 3,053-meter-high, ice- and snow-covered stratovolcano in the southwestern Cook Inlet region about 225 kilometers southwest of Anchorage and about 100 kilometers northwest of Homer. Historical eruptions of Iliamna Volcano have not been positively documented; however, the volcano regularly emits steam and gas, and small, shallow earthquakes are often detected beneath the summit area. The most recent eruptions of the volcano occurred about 300 years ago, and possibly as recently as 90-140 years ago. Prehistoric eruptions have generated plumes of volcanic ash, pyroclastic flows, and lahars that extended to the volcano flanks and beyond. Rock avalanches from the summit area have occurred numerous times in the past. These avalanches flowed several kilometers down the flanks and at least two large avalanches transformed to cohesive lahars. The number and distribution of known volcanic ash deposits from Iliamna Volcano indicate that volcanic ash clouds from prehistoric eruptions were significantly less voluminous and probably less common relative to ash clouds generated by eruptions of other Cook Inlet volcanoes. Plumes of volcanic ash from Iliamna Volcano would be a major hazard to jet aircraft using Anchorage International Airport and other local airports, and depending on wind direction, could drift at least as far as the Kenai Peninsula and beyond. Ashfall from future eruptions could disrupt oil and gas operations and shipping activities in Cook Inlet. Because Iliamna Volcano has not erupted for several hundred years, a future eruption could involve significant amounts of ice and snow that could lead to the formation of large lahars and downstream flooding. The greatest hazards in order of importance are described below and shown on plate 1.

  7. Elementary analysis of data from Tianchi Volcano

    Institute of Scientific and Technical Information of China (English)

    LIU Guo-ming; ZHANG Heng-rong; KONG Qing-jun; WU Cheng-zhi; GUO Feng; ZHANG Chao-fan

    2004-01-01

    Tianchi Volcano is the largest potential erupticve volcano in China. Analyzing these data on seismic monitoring, deformation observation and water chemistry investigation gained from the Tianchi Volcano Observatory (TVO), the authors consider that the Tianchi Volcano is in going into a new flourishing time.

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... appearance, size or contour of organs, tissues, and vessels or to detect abnormal masses, such as tumors. ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any ... size with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) Prostate Cancer Ultrasound- and MRI-Guided Prostate ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a more ... needle insertion) is usually minimal because the rectal wall is relatively insensitive to the pain in the ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... of the pelvis may be obtained as an alternative imaging test, because it may be obtained with ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  16. Ultrasound -- Pelvis

    Science.gov (United States)

    ... help diagnose symptoms experienced by women such as: pelvic pain abnormal bleeding other menstrual problems and help identify: ... children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient consultation. View full size with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... use of a small transducer (probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through the gel into the body. The transducer collects the sounds ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... use of a small transducer (probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through the gel into the body. The transducer collects the sounds ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty ... vessels or to detect abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page How is the procedure performed? In men, the prostate gland is located directly in front ... What are the limitations of Prostate Ultrasound Imaging? Men who have had the tail end of their ...

  14. Prostate Ultrasound

    Science.gov (United States)

    ... prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the object is as well as the object's size, shape and consistency (whether the object is solid ... ultrasound is used to detect changes in appearance, size or contour of organs, tissues, and vessels or ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... an ultrasound transducer – a plastic cylinder about the size of a finger – is inserted short distance into ... the object is as well as the object's size, shape and consistency (whether the object is solid ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are reviewed. top of page What will I experience during and after the procedure? For a transabdominal ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule found during ... difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the examination process. To ensure a smooth experience, it often helps to explain the procedure to the ... on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to distract the child and make the time pass quickly. The ultrasound exam room may have a ... tissue attenuate (weaken) the sound waves as they pass deeper into the body. top of page Additional ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... examinations do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured in real-time, they can show the structure and ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are also used to monitor the health and development of an embryo or fetus during pregnancy. See ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... also used to guide procedures such as needle biopsies , in which needles are used to extract a ... gynecologic examination. For a transrectal exam: If no biopsy is required, transrectal ultrasound of the prostate is ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. top ... be turned to either side to improve the quality of the images. After you are positioned on ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... small amount of gel is put on the skin to allow the sound waves to best travel ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... small amount of gel is put on the skin to allow the sound waves to best travel ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician ... the returning sound waves), as well as the type of body structure and composition of body tissue ...

  15. Hip Ultrasound

    Science.gov (United States)

    ... be used in infants to check for developmental dysplasia of the hip. Ultrasound is safe, noninvasive, and does not use ... be used to check the hips for developmental dysplasia of the hip (DDH), which in infants can range from a ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are obtained from different orientations to get the best views of the uterus and ovaries. Transvaginal ultrasound ... over time. Follow-up examinations are sometimes the best way to see if treatment is working or ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on the ... probe through the gel into the body. The transducer collects the sounds that bounce back and a ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs ... or uterine cancers A transvaginal ultrasound is usually performed to view ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a nodule found during a rectal exam, detect abnormalities, and determine whether the gland is enlarged. Ultrasound ... follow-up exam is done because a potential abnormality needs further evaluation with additional views or a ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that ... as clots) narrowing of vessels tumors and congenital vascular malformations reduced or absent blood flow to various ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... information you were looking for? Yes No Please type your comment or suggestion into the following text box: Comment: E-mail: ... Images related to Ultrasound - Prostate Sponsored by Please ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... prostate is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any ... with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) Prostate Cancer Ultrasound- and MRI-Guided Prostate ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... prior to the exam. Bringing books, small toys, music or games can help to distract the child ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  17. Ultrasound -- Pelvis

    Science.gov (United States)

    ... prior to the exam. Bringing books, small toys, music or games can help to distract the child ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of urinary and reproductive system disorders in both sexes without x-ray exposure. Risks For standard diagnostic ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician to ... computer or television monitor. The image is created based on the amplitude (loudness), frequency (pitch) and time ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule found during ... difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the examination process. To ensure a smooth experience, it often helps to explain the procedure to the ... on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient consultation. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's ( ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure. Ultrasound examinations are very sensitive to motion, and an active or crying child can prolong ... computer, which in turn creates a real-time picture on the monitor. One or more frames of ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician ... The transducer sends out inaudible, high—frequency sound waves into the body and then listens for the ...

  5. Disseminated intravascular coagulation in malaria: A case report

    Directory of Open Access Journals (Sweden)

    Laltanpuii Sailo

    2014-01-01

    Full Text Available Disseminated intravascular coagulation (DIC is seen in <5% of patients with severe Plasmodium falciparum malaria and is more common in cerebral malaria. Here, we report the diagnosis and management of a case of severe P. falciparum malaria with DIC.

  6. 21 CFR 880.5440 - Intravascular administration set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular administration set. 880.5440 Section 880.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...) Classification. Class II (special controls). The special control for pharmacy compounding systems within this...

  7. Detection of vascular morphology by high frequency intravascular ultrasonic imaging

    NARCIS (Netherlands)

    W.J. Gussenhoven (Wilhelmina Johanna); G.S. Madretsma (Guno); H. Pieterman; S.H.K. The (Salem); L. Wenguang; F.C. van Egmond (F.); N. Bom (Klaas)

    1991-01-01

    textabstractThis study was designed to validate the potential clinical utility of intravascular ultrasonic imaging in vitro and in vivo. In vitro studies were performed to assess the accuracy of dimensional and morphological information. In vitro images of human vessels (n = 75) demonstrated that le

  8. Heartbeat OCT: In vivo intravascular megahertz-optical coherence tomography

    NARCIS (Netherlands)

    T. Wang (Tianshi); A.F.H. Pfeiffer (Andreas); E.S. Regar (Eveline); W. Wieser (Wolfgang); H.M.M. van Beusekom (Heleen); C.T. Lancée (Charles); T. Springeling (Tirza); I. Krabbendam (Ilona); A.F.W. van der Steen (Ton); R. Huber (Roman); G. van Soest (Gijs)

    2015-01-01

    textabstractCardiac motion artifacts, non-uniform rotational distortion and undersampling affect the image quality and the diagnostic impact of intravascular optical coherence tomography (IV-OCT). In this study we demonstrate how these limitations of IV-OCT can be addressed by using an imaging syste

  9. Disseminated intravascular coagulopathy in dengue:a brief review

    Institute of Scientific and Technical Information of China (English)

    Viroj Wiwanitkit

    2009-01-01

    Dengue infection is an arboviral infection with a very high prevalence in tropical Southeast Asia.This infection presents as a clinical illness comprising of very high fever with several hematologic aberrations.In this article, the author briefly reviewed the report on disseminated intravascular coagulopathy (DIC),a severe complica-tion,in dengue.

  10. Detection of vascular morphology by high frequency intravascular ultrasonic imaging

    NARCIS (Netherlands)

    W.J. Gussenhoven (Wilhelmina Johanna); G.S. Madretsma (Guno); H. Pieterman; S.H.K. The (Salem); L. Wenguang; F.C. van Egmond (F.); N. Bom (Klaas)

    1991-01-01

    textabstractThis study was designed to validate the potential clinical utility of intravascular ultrasonic imaging in vitro and in vivo. In vitro studies were performed to assess the accuracy of dimensional and morphological information. In vitro images of human vessels (n = 75) demonstrated that le

  11. Retinal and choroidal intravascular spectral-domain optical coherence tomography

    DEFF Research Database (Denmark)

    Willerslev, Anne; Li, Xiao Qiang; Cordtz, Peter;

    2014-01-01

    flow in the retinal vessels in patients with ocular ischaemic syndrome and central retinal artery occlusion were both associated with lower reflectivity of the blood and an unstructured intravascular SD-OCT profile. Discussion:  This qualitative in vivo study found a characteristically structured SD...

  12. A Prognostic Dilemma of Basal Cell Carcinoma with Intravascular Invasion

    Science.gov (United States)

    Niumsawatt, Vachara; Castley, Andrew

    2016-01-01

    Summary: Basal cell carcinoma is the most common malignancy; however, it very rarely metastasizes. Despite the low mortality caused by this cancer, once it spreads, it has dim prognosis. We report a case of basal cell carcinoma with rare intravascular invasion and review the literature for risk factors and management of metastasis.

  13. Mount Rainier active cascade volcano

    Science.gov (United States)

    1994-01-01

    Mount Rainier is one of about two dozen active or recently active volcanoes in the Cascade Range, an arc of volcanoes in the northwestern United States and Canada. The volcano is located about 35 kilometers southeast of the Seattle-Tacoma metropolitan area, which has a population of more than 2.5 million. This metropolitan area is the high technology industrial center of the Pacific Northwest and one of the commercial aircraft manufacturing centers of the United States. The rivers draining the volcano empty into Puget Sound, which has two major shipping ports, and into the Columbia River, a major shipping lane and home to approximately a million people in southwestern Washington and northwestern Oregon. Mount Rainier is an active volcano. It last erupted approximately 150 years ago, and numerous large floods and debris flows have been generated on its slopes during this century. More than 100,000 people live on the extensive mudflow deposits that have filled the rivers and valleys draining the volcano during the past 10,000 years. A major volcanic eruption or debris flow could kill thousands of residents and cripple the economy of the Pacific Northwest. Despite the potential for such danger, Mount Rainier has received little study. Most of the geologic work on Mount Rainier was done more than two decades ago. Fundamental topics such as the development, history, and stability of the volcano are poorly understood.

  14. Mount Rainier active cascade volcano

    Science.gov (United States)

    Mount Rainier is one of about two dozen active or recently active volcanoes in the Cascade Range, an arc of volcanoes in the northwestern United States and Canada. The volcano is located about 35 kilometers southeast of the Seattle-Tacoma metropolitan area, which has a population of more than 2.5 million. This metropolitan area is the high technology industrial center of the Pacific Northwest and one of the commercial aircraft manufacturing centers of the United States. The rivers draining the volcano empty into Puget Sound, which has two major shipping ports, and into the Columbia River, a major shipping lane and home to approximately a million people in southwestern Washington and northwestern Oregon. Mount Rainier is an active volcano. It last erupted approximately 150 years ago, and numerous large floods and debris flows have been generated on its slopes during this century. More than 100,000 people live on the extensive mudflow deposits that have filled the rivers and valleys draining the volcano during the past 10,000 years. A major volcanic eruption or debris flow could kill thousands of residents and cripple the economy of the Pacific Northwest. Despite the potential for such danger, Mount Rainier has received little study. Most of the geologic work on Mount Rainier was done more than two decades ago. Fundamental topics such as the development, history, and stability of the volcano are poorly understood.

  15. Trauma Ultrasound.

    Science.gov (United States)

    Wongwaisayawan, Sirote; Suwannanon, Ruedeekorn; Prachanukool, Thidathit; Sricharoen, Pungkava; Saksobhavivat, Nitima; Kaewlai, Rathachai

    2015-10-01

    Ultrasound plays a pivotal role in the evaluation of acute trauma patients through the use of multi-site scanning encompassing abdominal, cardiothoracic, vascular and skeletal scans. In a high-speed polytrauma setting, because exsanguinations are the primary cause of trauma morbidity and mortality, ultrasound is used for quick and accurate detection of hemorrhages in the pericardial, pleural, and peritoneal cavities during the primary Advanced Trauma Life Support (ATLS) survey. Volume status can be assessed non-invasively with ultrasound of the inferior vena cava (IVC), which is a useful tool in the initial phase and follow-up evaluations. Pneumothorax can also be quickly detected with ultrasound. During the secondary survey and in patients sustaining low-speed or localized trauma, ultrasound can be used to help detect abdominal organ injuries. This is particularly helpful in patients in whom hemoperitoneum is not identified on an initial scan because findings of organ injuries will expedite the next test, often computed tomography (CT). Moreover, ultrasound can assist in detection of fractures easily obscured on radiography, such as rib and sternal fractures.

  16. Soufriere Hills Volcano

    Science.gov (United States)

    2002-01-01

    In this ASTER image of Soufriere Hills Volcano on Montserrat in the Caribbean, continued eruptive activity is evident by the extensive smoke and ash plume streaming towards the west-southwest. Significant eruptive activity began in 1995, forcing the authorities to evacuate more than 7,000 of the island's original population of 11,000. The primary risk now is to the northern part of the island and to the airport. Small rockfalls and pyroclastic flows (ash, rock and hot gases) are common at this time due to continued growth of the dome at the volcano's summit.This image was acquired on October 29, 2002 by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) on NASA's Terra satellite. With its 14 spectral bands from the visible to the thermal infrared wavelength region, and its high spatial resolution of 15 to 90 meters (about 50 to 300 feet), ASTER images Earth to map and monitor the changing surface of our planet.ASTER is one of five Earth-observing instruments launched December 18, 1999, on NASA's Terra satellite. The instrument was built by Japan's Ministry of Economy, Trade and Industry. A joint U.S./Japan science team is responsible for validation and calibration of the instrument and the data products.The broad spectral coverage and high spectral resolution of ASTER will provide scientists in numerous disciplines with critical information for surface mapping, and monitoring of dynamic conditions and temporal change. Example applications are: monitoring glacial advances and retreats; monitoring potentially active volcanoes; identifying crop stress; determining cloud morphology and physical properties; wetlands evaluation; thermal pollution monitoring; coral reef degradation; surface temperature mapping of soils and geology; and measuring surface heat balance.Dr. Anne Kahle at NASA's Jet Propulsion Laboratory, Pasadena, California, is the U.S. Science team leader; Bjorn Eng of JPL is the project manager. The Terra mission is part of NASA

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, ... through the blood vessels. top of page How is the procedure performed? For most ultrasound exams, you ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of the ... of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or sonography , ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  1. Characteristics of Hawaiian volcanoes

    Science.gov (United States)

    Poland, Michael P.; Takahashi, T. Jane; Landowski, Claire M.

    2014-01-01

    Founded in 1912 at the edge of the caldera of Kīlauea Volcano, HVO was the vision of Thomas A. Jaggar, Jr., a geologist from the Massachusetts Institute of Technology, whose studies of natural disasters around the world had convinced him that systematic, continuous observations of seismic and volcanic activity were needed to better understand—and potentially predict—earthquakes and volcanic eruptions. Jaggar summarized the aim of HVO by stating that “the work should be humanitarian” and have the goals of developing “prediction and methods of protecting life and property on the basis of sound scientific achievement.” These goals align well with those of the USGS, whose mission is to serve the Nation by providing reliable scientific information to describe and understand the Earth; minimize loss of life and property from natural disasters; manage natural resources; and enhance and protect our quality of life.

  2. Volcanoes in Eruption - Set 1

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The word volcano is used to refer to the opening from which molten rock and gas issue from Earth's interior onto the surface, and also to the cone, hill, or mountain...

  3. Volcanoes in Eruption - Set 2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The word volcano is used to refer to the opening from which molten rock and gas issue from Earth's interior onto the surface, and also to the cone, hill, or mountain...

  4. USGS Volcano Notification Service (VNS)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Website provides a subscription service to receive an email when changes occur in the activity levels for monitored U.S. volcanoes and/or when information releases...

  5. GLACIERS OF THE KORYAK VOLCANO

    Directory of Open Access Journals (Sweden)

    T. M. Manevich

    2012-01-01

    Full Text Available The paper presents main glaciological characteristics of present-day glaciers located on the Koryaksky volcano. The results of fieldwork (2008–2009 and high-resolution satellite image analysis let us to specify and complete information on modern glacial complex of Koryaksky volcano. Now there are seven glaciers with total area 8.36 km2. Three of them advance, two are in stationary state and one degrades. Moreover, the paper describes the new crater glacier.

  6. Therapeutic ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Crum, Lawrence A [Center for Industrial and Medical Ultrasound, 1013 NE 40th Street, University of Washington, Seattle, WA 98105 (United States)

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  7. Cintilografia do miocárdio com tecnécio 99m-MIBI e administração de adenosina em portadores de doença arterial coronária: correlação dos resultados com a angiografia coronária e o ultra-som intracoronário Adenosine myocardial perfusion SPECT with Tc-99m-MIBI in patients with obstructive coronary artery disease: correlation between quantitative coronary angiography and intravascular ultrasound measurements

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Mastrocolla

    2006-01-01

    Full Text Available OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM com Tecnécio 99m-MIBI (MIBI e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ e o ultra-som intracoronário (UIC como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC, encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E% de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79% e média de 44,20%, pOBJECTIVE: To correlate myocardial perfusion scintigraphy (MPS with Tc-99m-MIBI and adenosine infusion using quantitative coronary angiography (QCA and intravascular ultrasound (IVUS. METHODS: Seventy patients with coronary artery disease (CAD referred for myocardial perfusion scintigraphy (MPS with MIBI and adenosine were studied. Clinical, electrocardiographic (ECG, and scintigraphic findings were correlated with variables of visual and quantitative angiographic analysis, as well as to those of IVUS. RESULTS: The mean age of patients was 60.6 years, and 39 were male. Coronary angiography showed percentage of diameter stenosis (% DS of 49.94% in 105 arteries, 83 of which were re-evaluated by QCA (79%, mean of 44.20%, p<0.05. ST-segment depression during adenosine infusion was associated with higher degrees of % DS (55.0% vs. 47.8%, p<0.05. Scintigraphic ischemia was correlated with greater cross-sectional area of lumen obstruction by IVUS (% CSA. Clinical, ECG, and IVUS findings were considered together and expressed as global ischemic versus non-ischemic responses. Ischemia was associated with lower values of minimal lumen diameter (MLD and minimal lumen area

  8. Mahukona: The missing Hawaiian volcano

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M.O.; Muenow, D.W. (Univ. of Hawaii, Honolulu (USA)); Kurz, M.D. (Woods Hole Oceanographic Institution, MA (USA))

    1990-11-01

    New bathymetric and geochemical data indicate that a seamount west of the island of Hawaii, Mahukona, is a Hawaiian shield volcano. Mahukona has weakly alkalic lavas that are geochemically distinct. They have high {sup 3}He/{sup 4}He ratios (12-21 times atmosphere), and high H{sub 2}O and Cl contents, which are indicative of the early state of development of Hawaiian volcanoes. The He and Sr isotopic values for Mahukona lavas are intermediate between those for lavas from Loihi and Manuna Loa volcanoes and may be indicative of a temporal evolution of Hawaiian magmas. Mahukona volcano became extinct at about 500 ka, perhaps before reaching sea level. It fills the previously assumed gap in the parallel chains of volcanoes forming the southern segment of the Hawaiian hotspot chain. The paired sequence of volcanoes was probably caused by the bifurcation of the Hawaiian mantle plume during its ascent, creating two primary areas of melting 30 to 40 km apart that have persisted for at least the past 4 m.y.

  9. Ex vivo detection of macrophages in atherosclerotic plaques using intravascular ultrasonic-photoacoustic imaging

    Science.gov (United States)

    Quang Bui, Nhat; Hlaing, Kyu Kyu; Lee, Yong Wook; Kang, Hyun Wook; Oh, Junghwan

    2017-01-01

    Macrophages are excellent imaging targets for detecting atherosclerotic plaques as they are involved in all the developmental stages of atherosclerosis. However, no imaging technique is currently capable of visualizing macrophages inside blood vessel walls. The current study develops an intravascular ultrasonic-photoacoustic (IVUP) imaging system combined with indocyanine green (ICG) as a contrast agent to provide morphological and compositional information about the targeted samples. Both tissue-mimicking vessel phantoms and atherosclerotic plaque-mimicking porcine arterial tissues are used to demonstrate the feasibility of mapping macrophages labeled with ICG by endoscopically applying the proposed hybrid technique. A delay pulse triggering technique is able to sequentially acquire photoacoustic (PA) and ultrasound (US) signals from a single scan without using any external devices. The acquired PA and US signals are used to reconstruct 2D cross-sectional and 3D volumetric images of the entire tissue with the ICG-loaded macrophages injected. Due to high imaging contrast and sensitivity, the IVUP imaging vividly reveals structural information and detects the spatial distribution of the ICG-labeled macrophages inside the samples. ICG-assisted IVUP imaging can be a feasible imaging modality for the endoscopic detection of atherosclerotic plaques.

  10. Validating Intravascular Imaging with Serial Optical Coherence Tomography and Confocal Fluorescence Microscopy

    Science.gov (United States)

    Tardif, Pier-Luc; Bertrand, Marie-Jeanne; Abran, Maxime; Castonguay, Alexandre; Lefebvre, Joël; Stähli, Barbara E.; Merlet, Nolwenn; Mihalache-Avram, Teodora; Geoffroy, Pascale; Mecteau, Mélanie; Busseuil, David; Ni, Feng; Abulrob, Abedelnasser; Rhéaume, Éric; L’Allier, Philippe; Tardif, Jean-Claude; Lesage, Frédéric

    2016-01-01

    Atherosclerotic cardiovascular diseases are characterized by the formation of a plaque in the arterial wall. Intravascular ultrasound (IVUS) provides high-resolution images allowing delineation of atherosclerotic plaques. When combined with near infrared fluorescence (NIRF), the plaque can also be studied at a molecular level with a large variety of biomarkers. In this work, we present a system enabling automated volumetric histology imaging of excised aortas that can spatially correlate results with combined IVUS/NIRF imaging of lipid-rich atheroma in cholesterol-fed rabbits. Pullbacks in the rabbit aortas were performed with a dual modality IVUS/NIRF catheter developed by our group. Ex vivo three-dimensional (3D) histology was performed combining optical coherence tomography (OCT) and confocal fluorescence microscopy, providing high-resolution anatomical and molecular information, respectively, to validate in vivo findings. The microscope was combined with a serial slicer allowing for the imaging of the whole vessel automatically. Colocalization of in vivo and ex vivo results is demonstrated. Slices can then be recovered to be tested in conventional histology. PMID:27983695

  11. Validating Intravascular Imaging with Serial Optical Coherence Tomography and Confocal Fluorescence Microscopy

    Directory of Open Access Journals (Sweden)

    Pier-Luc Tardif

    2016-12-01

    Full Text Available Atherosclerotic cardiovascular diseases are characterized by the formation of a plaque in the arterial wall. Intravascular ultrasound (IVUS provides high-resolution images allowing delineation of atherosclerotic plaques. When combined with near infrared fluorescence (NIRF, the plaque can also be studied at a molecular level with a large variety of biomarkers. In this work, we present a system enabling automated volumetric histology imaging of excised aortas that can spatially correlate results with combined IVUS/NIRF imaging of lipid-rich atheroma in cholesterol-fed rabbits. Pullbacks in the rabbit aortas were performed with a dual modality IVUS/NIRF catheter developed by our group. Ex vivo three-dimensional (3D histology was performed combining optical coherence tomography (OCT and confocal fluorescence microscopy, providing high-resolution anatomical and molecular information, respectively, to validate in vivo findings. The microscope was combined with a serial slicer allowing for the imaging of the whole vessel automatically. Colocalization of in vivo and ex vivo results is demonstrated. Slices can then be recovered to be tested in conventional histology.

  12. "Mediterranean volcanoes vs. chain volcanoes in the Carpathians"

    Science.gov (United States)

    Chivarean, Radu

    2017-04-01

    Volcanoes have always represent an attractive subject for students. Europe has a small number of volcanoes and Romania has none active ones. The curricula is poor in the study of volcanoes. We want to make a parallel between the Mediterranean active volcanoes and the old extinct ones in the Oriental Carpathians. We made an comparison of the two regions in what concerns their genesis, space and time distribution, the specific relief and the impact in the landscape, consequences of their activities, etc… The most of the Mediterranean volcanoes are in Italy, in the peninsula in Napoli's area - Vezuviu, Campi Flegrei, Puzzoli, volcanic islands in Tirenian Sea - Ischia, Aeolian Islands, Sicily - Etna and Pantelleria Island. Santorini is located in Aegean Sea - Greece. Between Sicily and Tunisia there are 13 underwater volcanoes. The island called Vulcano, it has an active volcano, and it is the origin of the word. Every volcano in the world is named after this island, just north of Sicily. Vulcano is the southernmost of the 7 main Aeolian Islands, all volcanic in origin, which together form a small island arc. The cause of the volcanoes appears to be a combination of an old subduction event and tectonic fault lines. They can be considered as the origin of the science of volcanology. The volcanism of the Carpathian region is part of the extensive volcanic activity in the Mediterranean and surrounding regions. The Carpathian Neogene/Quaternary volcanic arc is naturally subdivided into six geographically distinct segments: Oas, Gutai, Tibles, Calimani, Gurghiu and Harghita. It is located roughly between the Carpathian thrust-and-fold arc to the east and the Transylvanian Basin to the west. It formed as a result of the convergence between two plate fragments, the Transylvanian micro-plate and the Eurasian plate. Volcanic edifices are typical medium-sized andesitic composite volcanoes, some of them attaining the caldera stage, complicated by submittal or peripheral domes

  13. Disseminated intravascular coagulation in term and preterm neonates.

    Science.gov (United States)

    Veldman, Alex; Fischer, Doris; Nold, Marcel F; Wong, Flora Y

    2010-06-01

    Among critically ill patients, the risk of developing disseminated intravascular coagulation (DIC) is probably highest in neonates. Low plasma reserves in pro- and anticoagulant coagulation factors, intravascular volume contraction after birth, and a high incidence of hypoxia and sepsis in critically ill newborns rapidly lead to a decompensation of the coagulation system in this population. Global coagulation tests and single-factor plasma levels have to be interpreted in the context of age-corrected normal ranges. Platelet consumption and reduced protein C plasma levels have diagnostic value; the latter also has prognostic potential in neonates with DIC and sepsis. Therapeutic success relies heavily on reversal of the underlying condition. Some coagulation-specific therapies have been explored in small studies and case series with varying success and sometimes conflicting results. Therefore, larger controlled trials in this common and serious condition are urgently needed.

  14. Disseminated intravascular coagulation: a review for the internist.

    Science.gov (United States)

    Levi, Marcel; van der Poll, Tom

    2013-02-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. Recent knowledge on important pathogenetic mechanisms that may lead to DIC has resulted in novel preventive and therapeutic approaches to patients with DIC. The diagnosis of DIC can be made by sensitive laboratory tests; however, most of these tests are not readily available in a clinical setting. A reliable diagnosis can also be made on the basis of a small series of laboratory tests that can be combined in a scoring algorithm. The cornerstone of the management of DIC is the specific and vigorous treatment of the underlying disorder. Strategies aimed at the inhibition of coagulation activation may theoretically be justified and have been found beneficial in experimental and clinical studies. These strategies comprise inhibition of tissue factor-mediated activation of coagulation or restoration of physiological anticoagulant pathways.

  15. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    2006-01-01

    that the relaxivity of intravascular contrast agents depends significantly on the host tissue. This agrees with experimental data by Johnson et al. (Magn Reson Med 2000;44:909). In particular, the present results suggest a several-fold increase in the relaxivity of Gd-based contrast agents in brain tissue compared...... with bulk blood. The enhancement of relaxation in tissue is due to the contrast in magnetic susceptibility between blood vessels and parenchyma induced by the presence of paramagnetic tracer. Beyond the perfusion measurements, the results can be applied to quantitation of functional MRI and to vessel size......The concentration of MRI tracers cannot be measured directly by MRI and is commonly evaluated indirectly using their relaxation effect. This study develops a comprehensive theoretical model to describe the transverse relaxation in perfused tissue caused by intravascular tracers. The model takes...

  16. Intravascular papillary endothelial hyperplasia: An unusual histopathological entity.

    Science.gov (United States)

    Mahapatra, Qury S; Sahai, Kavita; Malik, Ajay; Mani, N S

    2015-01-01

    Intravascular papillary endothelial hyperplasia (Masson's tumor) is a benign lesion of the skin and subcutaneous tissue consisting of a reactive proliferation of endothelial cells with papillary formations related to a thrombus. It poses a diagnostic challenge as the clinical signs and symptoms are nonspecific and may mimic a soft tissue sarcoma. The diagnosis is based on histopathology. Here we report two cases of Masson's hemangioma occurring on the upper lip and on the left hand.

  17. Intravascular papillary endothelial hyperplasia: An unusual histopathological entity

    Directory of Open Access Journals (Sweden)

    Qury S Mahapatra

    2015-01-01

    Full Text Available Intravascular papillary endothelial hyperplasia (Masson′s tumor is a benign lesion of the skin and subcutaneous tissue consisting of a reactive proliferation of endothelial cells with papillary formations related to a thrombus. It poses a diagnostic challenge as the clinical signs and symptoms are nonspecific and may mimic a soft tissue sarcoma. The diagnosis is based on histopathology. Here we report two cases of Masson′s hemangioma occurring on the upper lip and on the left hand.

  18. Intravascular papillary endothelial hyperplasia of the mandibular lingual mucosa

    Institute of Scientific and Technical Information of China (English)

    Benay Tokman; (S)ebnem (S)im(s)ek; Erkan Erkmen; Tülin Oygur

    2004-01-01

    @@ In 1923, Masson1 described an unusual papillary endothelial proliferation that he named as "hemangioendotheliome vegetant intravasculaire". In 1976, Clearkin and Enzinger2 coined the term intravascular papillary endothelial hyperplasia (IPEH) that is now in use. This term refers to the presence of endothelium lined papillary projections within a vascular space. Characteristically, the papillary structures are composed of a single layer of swollen or plump endothelial cells without cellular pleomorphism, mitotic activity or necrosis.

  19. Silent intravascular lymphoma initially manifesting as a unilateral adrenal incidentaloma.

    Science.gov (United States)

    Takahashi, Yoshiko; Iida, Keiji; Hino, Yasuhisa; Ohara, Takeshi; Kurahashi, Toshifumi; Tashiro, Takashi; Chihara, Kazuo

    2012-01-01

    Intravascular large B-cell lymphoma (IVLBCL) is a rare subtype of malignant lymphoma. Although the involvement of adrenal glands in IVLBCL is often observed, primary adrenal IVLBCL is rare. Most reported cases of adrenal IVLBCL showed bilateral lesions resulting in rapidly progressive adrenal failure and poor prognosis. Here, we report a case of slowly progressive primary adrenal IVLBCL manifesting initially with unilateral adrenal incidentaloma. This case is a silent IVLBCL and shows that the enlargement of both adrenal glands can be followed.

  20. Asian-variant intravascular lymphoma in the African race

    OpenAIRE

    Holly Geyer; Nina Karlin; Brian Palen; Ruben Mesa

    2012-01-01

    Intravascular large B-cell lymphoma (IVLBCL) is an exceptionally rare form of non- Hodgkin lymphoma (NHL) distinguished by the preferential growth of neoplastic cells within blood vessel lumen. Challenging to detect and deemed disseminated at diagnosis, this condition is characterized by a highly aggressive, inconspicuous course with a high mortality rate. We describe the case of a 48 year-old African-American female presenting with a two month history of low-grade fevers and malaise. Laborat...

  1. Asian-variant intravascular lymphoma in the African race

    Directory of Open Access Journals (Sweden)

    Holly Geyer

    2012-03-01

    Full Text Available Intravascular large B-cell lymphoma (IVLBCL is an exceptionally rare form of non- Hodgkin lymphoma (NHL distinguished by the preferential growth of neoplastic cells within blood vessel lumen. Challenging to detect and deemed disseminated at diagnosis, this condition is characterized by a highly aggressive, inconspicuous course with a high mortality rate. We describe the case of a 48 year-old African-American female presenting with a two month history of low-grade fevers and malaise. Laboratory data was notable for anemia, thrombocytopenia, elevated liver function tests, and hematuria. An extensive workup for infectious, rheumatologic and malignant causes was negative. Her symptoms progressed and within two weeks, she was admitted for disseminated intravascular coagulation (DIC. Her course was complicated by diffuse pulmonary hemorrhage and ultimately, care was withdrawn. Autopsy identified widespread CD-20 positive intravascular large B-cell lymphoma with significant hepatosplenic involvement, characteristic of the Asian variant IVLBCL. This case uniquely highlights development of the Asian variant IVLBVL in a previously undescribed race. Identified by its intraluminal vascular growth pattern, IVLBCL generally spares lymphatic channels. Diagnosis and differentiation of this condition from other hematological malignancies via skin, visceral and bone marrow biopsy is imperative as anthracycline-containing chemotherapies may significantly improve clinical outcomes. This article outlines the common presentation, natural course, and treatment options of IVLBCL, along with the histopathology, immunohistochemistry, and chromosomal aberrations common to this condition.

  2. Intravascular foreign bodies: danger of unretrieved fragmented medical devices.

    Science.gov (United States)

    Tateishi, Minori; Tomizawa, Yasuko

    2009-01-01

    A warning on the danger of unretrieved device fragments and recommendations to mitigate the danger were issued by the Food and Drug Administration in January 2008. The causes of intravascular foreign bodies are classified into three main categories: improper manipulation and usage, device defects, and others, such as patient and anatomical factors. Device failure after long-term use is rarely predicted at the time of approval, since device abnormality is rarely experienced in animal studies and clinical trials conducted during development of the device. Stent fracture due to metal fatigue is one example. Complex complications could occur from simultaneous use of two or more devices with diverse characteristics. The success rate of percutaneous retrieval of intravascular foreign bodies has improved with the advances in commercially available devices. However, the procedure is not always successful and sometimes surgical removal becomes necessary. Appropriate device selection and acquisition of experience in using the device are important. When an intravascular foreign body cannot be retrieved, the risk of complication could be high. Magnetic resonance imaging examination sometimes causes adverse events, including burns due to the heat generated by metal movement. Such information should be correctly recorded. Furthermore, it is necessary to provide patients with adequate information about the characteristics of implanted devices and unretrieved fragments. We reviewed the literature on unretrieved medical device fragments and include articles that describe the Japanese experience.

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through ... during a single exam. The transducer sends out high-frequency sound waves (that the human ear cannot hear) ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through ... during a single exam. The transducer sends out high-frequency sound waves (that the human ear cannot hear) ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... with caption Pediatric Content Some imaging tests and treatments have special pediatric ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis ... imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  9. Intravascular Talcosis due to Intravenous Drug Use Is an Underrecognized Cause of Pulmonary Hypertension

    Directory of Open Access Journals (Sweden)

    Christopher C. Griffith

    2012-01-01

    Full Text Available Intravenous injection of illegal drugs or medications meant for oral administration can cause granulomatous disease of the lung. This intravascular talcosis results in pulmonary fibrosis and pulmonary hypertension. Nine cases of histologically confirmed intravascular talcosis were reviewed with specific attention given to the clinical histories in these patients. Five autopsy cases were included in this series with detailed investigation in the anatomic features associated with intravascular talcosis and pulmonary hypertension. All nine patients showed perivascular and/or intravascular deposition of polarizable foreign material in their lungs. Intravascular talcosis as a result of previous intravenous drug use was not clinically suspected in any patient despite clinically diagnosed pulmonary hypertension in five. All patients showed dilatation of the right and left heart, but none had dilatation of the aortic valve. Congestive heart failure with hepatosplenomegaly was also common. We conclude that intravascular talcosis is an underdiagnosed cause of pulmonary hypertension in patients with known history of intravenous drug use.

  10. Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Garcia-Garcia, Hector M

    2015-01-01

    We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the s......We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI...... in the setting of IBIS-4 study. IBIS4 (NCT00962416) is a prospective cohort study conducted at five European centers including 103 STEMI patients who underwent serial three-vessel coronary imaging during primary PCI and at 13 months. The feasibility parameter was successful imaging, defined as the number...... with the results from a cohort of 485 STEMI patients undergoing primary PCI without additional imaging. Imaging of the infarct-related artery at baseline (and follow-up) was successful in 92.2% (96.6%) of patients using OCT and in 93.2% (95.5%) using IVUS. Imaging of the non-infarct-related vessels was successful...

  11. Wideband Optical Detector of Ultrasound for Medical Imaging Applications

    Science.gov (United States)

    Rosenthal, Amir; Kellnberger, Stephan; Omar, Murad; Razansky, Daniel; Ntziachristos, Vasilis

    2014-01-01

    Optical sensors of ultrasound are a promising alternative to piezoelectric techniques, as has been recently demonstrated in the field of optoacoustic imaging. In medical applications, one of the major limitations of optical sensing technology is its susceptibility to environmental conditions, e.g. changes in pressure and temperature, which may saturate the detection. Additionally, the clinical environment often imposes stringent limits on the size and robustness of the sensor. In this work, the combination of pulse interferometry and fiber-based optical sensing is demonstrated for ultrasound detection. Pulse interferometry enables robust performance of the readout system in the presence of rapid variations in the environmental conditions, whereas the use of all-fiber technology leads to a mechanically flexible sensing element compatible with highly demanding medical applications such as intravascular imaging. In order to achieve a short sensor length, a pi-phase-shifted fiber Bragg grating is used, which acts as a resonator trapping light over an effective length of 350 µm. To enable high bandwidth, the sensor is used for sideway detection of ultrasound, which is highly beneficial in circumferential imaging geometries such as intravascular imaging. An optoacoustic imaging setup is used to determine the response of the sensor for acoustic point sources at different positions. PMID:24895083

  12. Mud Volcanoes Formation And Occurrence

    Science.gov (United States)

    Guliyev, I. S.

    2007-12-01

    Mud volcanoes are natural phenomena, which occur throughout the globe. They are found at a greater or lesser scale in Azerbaijan, Turkmenistan, Georgia, on the Kerch and Taman peninsulas, on Sakhalin Island, in West Kuban, Italy, Romania, Iran, Pakistan, India, Burma, China, Japan, Indonesia, Malaysia, New Zealand, Mexico, Colombia, Trinidad and Tobago, Venezuela and Ecuador. Mud volcanoes are most well-developed in Eastern Azerbaijan, where more than 30% of all the volcanoes in the world are concentrated. More than 300 mud volcanoes have already been recognized here onshore or offshore, 220 of which lie within an area of 16,000 km2. Many of these mud volcanoes are particularly large (up to 400 m high). The volcanoes of the South Caspian form permanent or temporary islands, and numerous submarine banks. Many hypotheses have been developed regarding the origin of mud volcanoes. Some of those hypotheses will be examined in the present paper. Model of spontaneous excitation-decompaction (proposed by Ivanov and Guliev, 1988, 2002). It is supposed that one of major factors of the movement of sedimentary masses and formation of hydrocarbon deposits are phase transitions in sedimentary basin. At phase transitions there are abnormal changes of physical and chemical parameters of rocks. Abnormal (high and negative) pressure takes place. This process is called as excitation of the underground environment with periodicity from several tens to several hundreds, or thousand years. The relationship between mud volcanism and the generation of hydrocarbons, particularly methane, is considered to be a critical factor in mud volcano formation. At high flow rates the gas and sediment develops into a pseudo-liquid state and as flow increases the mass reaches the "so-called hover velocity" where mass transport begins. The mass of fluid moves as a quasi-uniform viscous mass through the sediment pile in a piston like manner until expelled from the surface as a "catastrophic eruption

  13. Disseminated intravascular large-cell lymphoma with initial presentation mimicking Guillain-Barré syndrome.

    Science.gov (United States)

    Jiang, Qin Li; Pytel, Peter; Rowin, Julie

    2010-07-01

    We report a patient with intravascular large B-cell lymphoma who initially presented with acute ascending weakness and sensory changes. Electrodiagnostic testing and cerebral spinal fluid (CSF) studies were initially suggestive of a demyelinating polyneuropathy. Further clinical evaluation and testing were consistent with mononeuropathy multiplex. Autopsy revealed disseminated intravascular large-cell lymphoma. Intravascular large-cell lymphoma should be considered in the differential diagnosis of a rapidly evolving neuropathy associated with other organ involvement.

  14. Intravascular large B-cell lymphoma presenting with fulminant pseudomembranous colitis.

    Science.gov (United States)

    Wang, Tao; Ghaffar, Hasan; Grin, Andrea

    2013-05-01

    Intravascular large B-cell lymphoma is a rare entity that usually presents in late stages with non-specific symptoms. We present a case of an incidentally discovered intravascular large B-cell lymphoma in a 78-year-old man who underwent colectomy for medically refractory pseudomembranous colitis. The malignant lymphocytes were preferentially localized to small colonic submucosal vasculature, without any evidence of an extravascular tumor mass. The gastrointestinal system is an exceeding rare initial diagnostic site for intravascular lymphoma, and presentation with pseudomembranous colitis has not been previously reported. We discuss the current definition of intravascular lymphoma, clinicopathological variants, differential diagnoses, as well as current therapy.

  15. Global Volcano Model

    Science.gov (United States)

    Sparks, R. S. J.; Loughlin, S. C.; Cottrell, E.; Valentine, G.; Newhall, C.; Jolly, G.; Papale, P.; Takarada, S.; Crosweller, S.; Nayembil, M.; Arora, B.; Lowndes, J.; Connor, C.; Eichelberger, J.; Nadim, F.; Smolka, A.; Michel, G.; Muir-Wood, R.; Horwell, C.

    2012-04-01

    Over 600 million people live close enough to active volcanoes to be affected when they erupt. Volcanic eruptions cause loss of life, significant economic losses and severe disruption to people's lives, as highlighted by the recent eruption of Mount Merapi in Indonesia. The eruption of Eyjafjallajökull, Iceland in 2010 illustrated the potential of even small eruptions to have major impact on the modern world through disruption of complex critical infrastructure and business. The effects in the developing world on economic growth and development can be severe. There is evidence that large eruptions can cause a change in the earth's climate for several years afterwards. Aside from meteor impact and possibly an extreme solar event, very large magnitude explosive volcanic eruptions may be the only natural hazard that could cause a global catastrophe. GVM is a growing international collaboration that aims to create a sustainable, accessible information platform on volcanic hazard and risk. We are designing and developing an integrated database system of volcanic hazards, vulnerability and exposure with internationally agreed metadata standards. GVM will establish methodologies for analysis of the data (eg vulnerability indices) to inform risk assessment, develop complementary hazards models and create relevant hazards and risk assessment tools. GVM will develop the capability to anticipate future volcanism and its consequences. NERC is funding the start-up of this initiative for three years from November 2011. GVM builds directly on the VOGRIPA project started as part of the GRIP (Global Risk Identification Programme) in 2004 under the auspices of the World Bank and UN. Major international initiatives and partners such as the Smithsonian Institution - Global Volcanism Program, State University of New York at Buffalo - VHub, Earth Observatory of Singapore - WOVOdat and many others underpin GVM.

  16. Remote Sensing of Active Volcanoes

    Science.gov (United States)

    Francis, Peter; Rothery, David

    The synoptic coverage offered by satellites provides unparalleled opportunities for monitoring active volcanoes, and opens new avenues of scientific inquiry. Thermal infrared radiation can be used to monitor levels of activity, which is useful for automated eruption detection and for studying the emplacement of lava flows. Satellite radars can observe volcanoes through clouds or at night, and provide high-resolution topographic data. In favorable conditions, radar inteferometery can be used to measure ground deformation associated with eruptive activity on a centimetric scale. Clouds from explosive eruptions present a pressing hazard to aviation; therefore, techniques are being developed to assess eruption cloud height and to discriminate between ash and meterological clouds. The multitude of sensors to be launched on future generations of space platforms promises to greatly enhance volcanological studies, but a satellite dedicated to volcanology is needed to meet requirements of aviation safety and volcano monitoring.

  17. Mount Rainier: A decade volcano

    Science.gov (United States)

    Swanson, Donald A.; Malone, Stephen D.; Samora, Barbara A.

    Mount Rainier, the highest (4392 m) volcano in the Cascade Range, towers over a population of more than 2.5 million in the Seattle-Tacoma metropolitan area, and its drainage system via the Columbia River potentially affects another 500,000 residents of southwestern Washington and northwestern Oregon (Figure 1). Mount Rainier is the most hazardous volcano in the Cascades in terms of its potential for magma-water interaction and sector collapse. Major eruptions, or debris flows even without eruption, pose significant dangers and economic threats to the region. Despite such hazard and risk, Mount Rainier has received little study; such important topics as its petrologic and geochemical character, its proximal eruptive history, its susceptibility to major edifice failure, and its development over time have been barely investigated. This situation may soon change because of Mount Rainier's recent designation as a “Decade Volcano.”

  18. Systematic radon survey over active volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, J.L.; Monnin, M.; Garcia Vindas, J.R. [Centre National de la Recherche Cientifique, Montpellier (France). Lab. GBE; Ricard, L.P.; Staudacher, T. [Observatoire Volcanologique Du Pitou de la Fournaise, La Plaine des Cafres (France)

    1999-08-01

    Data obtained since 1993 on Costa Rica volcanos are presented and radon anomalies recorded before the eruption of the Irazu volcano (December 8, 1994) are discussed. The Piton de la Fournaise volcano is inactive since mid 1992. The influence of the external parameters on the radon behaviour is studied and the type of perturbations induced on short-term measurements are individuate.

  19. Alaska volcanoes guidebook for teachers

    Science.gov (United States)

    Adleman, Jennifer N.

    2011-01-01

    Alaska’s volcanoes, like its abundant glaciers, charismatic wildlife, and wild expanses inspire and ignite scientific curiosity and generate an ever-growing source of questions for students in Alaska and throughout the world. Alaska is home to more than 140 volcanoes, which have been active over the last 2 million years. About 90 of these volcanoes have been active within the last 10,000 years and more than 50 of these have been active since about 1700. The volcanoes in Alaska make up well over three-quarters of volcanoes in the United States that have erupted in the last 200 years. In fact, Alaska’s volcanoes erupt so frequently that it is almost guaranteed that an Alaskan will experience a volcanic eruption in his or her lifetime, and it is likely they will experience more than one. It is hard to imagine a better place for students to explore active volcanism and to understand volcanic hazards, phenomena, and global impacts. Previously developed teachers’ guidebooks with an emphasis on the volcanoes in Hawaii Volcanoes National Park (Mattox, 1994) and Mount Rainier National Park in the Cascade Range (Driedger and others, 2005) provide place-based resources and activities for use in other volcanic regions in the United States. Along the lines of this tradition, this guidebook serves to provide locally relevant and useful resources and activities for the exploration of numerous and truly unique volcanic landscapes in Alaska. This guidebook provides supplemental teaching materials to be used by Alaskan students who will be inspired to become educated and prepared for inevitable future volcanic activity in Alaska. The lessons and activities in this guidebook are meant to supplement and enhance existing science content already being taught in grade levels 6–12. Correlations with Alaska State Science Standards and Grade Level Expectations adopted by the Alaska State Department of Education and Early Development (2006) for grades six through eleven are listed at

  20. Contrast-enhanced ultrasound imaging of the vasa vasorum of carotid artery plaque

    Institute of Scientific and Technical Information of China (English)

    Ze-Zhou; Song; Yan-Ming; Zhang

    2015-01-01

    The vasa vasorum of carotid artery plaque is a novel marker of accurately evaluating the vulnerability of carotid artery plaque, which was associated with symptomatic cerebrovascular and cardiovascular disease. The presence of ultrasound contrast agents in carotid artery plaque represents the presence of the vasa vasorum in carotid artery plaque because the ultrasoundcontrast agents are strict intravascular tracers. Therefore, contrast-enhanced ultrasound(CEUS) is a novel and safe imaging modality for evaluating the vasa vasorum in carotid artery plaque. However, there are some issues that needs to be assessed to embody fully the clinical utility of the vasa vasorum in carotid artery plaque with CEUS.

  1. Low variation and high reproducibility in plaque volume with intravascular ultrasound

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Pedersen, Knud Erik;

    2004-01-01

    by electrocardiographic-gated three-dimensional (3D) IVUS in 20 male patients with ischaemic heart disease (IHD). RESULTS: The study lesions were angiographically insignificant, with a length of the analysed segment on 11.4+/-5.9 mm. At baseline the mean minimal lumen diameter was 2.41+/-0.59 mm, minimal lumen area 4.......82+/-2.38 mm2, and maximal plaque burden 65.61+/-9.57%. Mean reference diameter was 3.1+/-0.6 mm. No significant changes were observed in volumes of total vessel, lumen or plaque. The coefficient of variation (CV) for two volume measurements at baseline was: vessel 0.8%, plaque 1.3%, and lumen 1.......4%. For measurements recorded at baseline and after 12.6+/-1.5 weeks, CV was respectively 3.5%, 3.3% and 6.6%. Reproducibility and interobserver and intraobserver variation showed very high correlations. A linear correlation was present in percent changes over 12.6+/-1.5 weeks between vessel volume and lumen volume (r...

  2. Effect and outcome of balloon angioplasty and stenting of the iliac arteries evaluated by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K J; Rasmussen, John Bøje Grønvall; Just, S;

    1999-01-01

    To document the mechanism of percutaneous transluminal angioplasty (PTA) and stenting of the iliac arteries, and to relate the effect to patency.......To document the mechanism of percutaneous transluminal angioplasty (PTA) and stenting of the iliac arteries, and to relate the effect to patency....

  3. The use of intravascular ultrasound for intraoperative assessment during semiclosed thromboendarterectomy

    DEFF Research Database (Denmark)

    Vogt, K C; Sillesen, H; Schroeder, T V

    1998-01-01

    and restenosis (> 50%) had developed in two (10%). At this point, patency cannot be related to IVUS findings. We conclude that IVUS is a feasible method for intraoperative assessment of semiclosed TEA. The rate of early failures due to residual material might be reduced by this new application of IVUS....

  4. The use of intravascular ultrasound for intraoperative assessment during semiclosed thromboendarterectomy

    DEFF Research Database (Denmark)

    Vogt, K C; Sillesen, H; Schroeder, T V

    1998-01-01

    in the artery proximal to the endarterectomized area were measured and, along with any remaining material, related to patency. Patency was evaluated at clinical controls after 3, 6, 12 and 24 months with duplex scanning and ankle-brachial index. In 10 cases (50%), material left behind from the endarterectomy...

  5. Intravascular ultrasound-guided stenting of left main stem dissection after medtronic corevalve implantation

    NARCIS (Netherlands)

    N.M. van Mieghem (Nicolas); P.P.T. de Jaegere (Peter)

    2013-01-01

    textabstractTranscatheter aortic valve implantation (TAVI) implies the introduction, positioning, and deployment of a stented bioprosthesis in the (calcified) native aortic valve. We report an at first glance uneventful TAVI with the Medtronic Corevalve System, which was followed by transient electr

  6. The use of intravascular ultrasound as control procedure for the deployment of endovascular stented grafts

    DEFF Research Database (Denmark)

    Vogt, K C; Brunkwall, J; Malina, M;

    1997-01-01

    from guidewires or the introducer system. Imaging during stent deployment was abandoned after IVUS catheter damage in two of three cases. Postprocedural IVUS was able to evaluate the expansion of the stents and the adaptation to the aortic wall in all instances. In four (29%) cases a leak...... was identified. Additional intervention included deployment of a further stent (n = 2) or redilation (n = 2). Covering of the renal arteries could only be indirectly determined by IVUS. CONCLUSION: IVUS can provide important decisive information before and after stented graft deployment, with the limitations...

  7. Three-dimensional intravascular ultrasound assessment of noninjured edges of beta-irradiated coronary segments

    NARCIS (Netherlands)

    K. Kozuma (Ken); M.A. Costa (Marco); M. Sabaté (Manel); I.P. Kay (Ian Patrick); J.P. Marijnissen (Johannes); V.L.M.A. Coen (Veronique); P. Serrano (Pedro); J.M.R. Ligthart (Jürgen); P.W.J.C. Serruys (Patrick); P.C. Levendag (Peter)

    2000-01-01

    textabstractBACKGROUND: The "edge effect," late lumen loss at the margins of the treated segment, has become an important issue in the field of coronary brachytherapy. The aim of the present study was to assess the edge effect in noninjured margins adjacent to the irradiated segmen

  8. Validation and application of intravascular ultrasound in endovascular treatment of abdominal aortic aneurysm

    NARCIS (Netherlands)

    J.A. van Essen (Anthonie)

    2000-01-01

    textabstractAn abdominal aortic aneurysm (AAA) is a localized and permanent dilatation of the aorta that presents a clear danger for the patient because of the risk of rupture. The chance of rupture increases with the size of the aneurysm. Mortality after rupture is high: 60-70% of patients with

  9. Computer-aided detection of intracoronary stent in intravascular ultrasound sequences

    NARCIS (Netherlands)

    Ciompi, F.; Balocco, S.; Rigla, J.; Carrillo, X.; Mauri, J.; Radeva, P.

    2016-01-01

    PURPOSE: An intraluminal coronary stent is a metal mesh tube deployed in a stenotic artery during percutaneous coronary intervention (PCI), in order to prevent acute vessel occlusion. The identification of struts location and the definition of the stent shape is relevant for PCI planning and for

  10. Intravascular ultrasound-guided stenting of left main stem dissection after medtronic corevalve implantation

    NARCIS (Netherlands)

    N.M. van Mieghem (Nicolas); P.P.T. de Jaegere (Peter)

    2013-01-01

    textabstractTranscatheter aortic valve implantation (TAVI) implies the introduction, positioning, and deployment of a stented bioprosthesis in the (calcified) native aortic valve. We report an at first glance uneventful TAVI with the Medtronic Corevalve System, which was followed by transient electr

  11. Validation and application of intravascular ultrasound in endovascular treatment of abdominal aortic aneurysm

    NARCIS (Netherlands)

    J.A. van Essen (Anthonie)

    2000-01-01

    textabstractAn abdominal aortic aneurysm (AAA) is a localized and permanent dilatation of the aorta that presents a clear danger for the patient because of the risk of rupture. The chance of rupture increases with the size of the aneurysm. Mortality after rupture is high: 60-70% of patients with a r

  12. Preliminary volcano-hazard assessment for Augustine Volcano, Alaska

    Science.gov (United States)

    Waythomas, Christopher F.; Waitt, Richard B.

    1998-01-01

    Augustine Volcano is a 1250-meter high stratovolcano in southwestern Cook Inlet about 280 kilometers southwest of Anchorage and within about 300 kilometers of more than half of the population of Alaska. Explosive eruptions have occurred six times since the early 1800s (1812, 1883, 1935, 1964-65, 1976, and 1986). The 1976 and 1986 eruptions began with an initial series of vent-clearing explosions and high vertical plumes of volcanic ash followed by pyroclastic flows, surges, and lahars on the volcano flanks. Unlike some prehistoric eruptions, a summit edifice collapse and debris avalanche did not occur in 1812, 1935, 1964-65, 1976, or 1986. However, early in the 1883 eruption, a portion of the volcano summit broke loose forming a debris avalanche that flowed to the sea. The avalanche initiated a small tsunami reported on the Kenai Peninsula at English Bay, 90 kilometers east of the volcano. Plumes of volcanic ash are a major hazard to jet aircraft using Anchorage International and other local airports. Ashfall from future eruptions could disrupt oil and gas operations and shipping activities in Cook Inlet. Eruptions similar to the historical and prehistoric eruptions are likely in Augustine's future.

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... data into 3-D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ... usually stain or discolor clothing. In some ultrasound studies, the transducer is attached to a probe and ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... not stain or discolor clothing. In some ultrasound studies, the transducer is attached to a probe and ...

  18. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  19. Breast ultrasound.

    Science.gov (United States)

    Ueno, E

    1996-03-01

    In ultrasound, ultrasonic images are formed by means of echoes among tissues with different acoustic impedance. Acoustic impedance is the product of sound speed and bulk modulus. The bulk modulus expresses the elasticity of an object, and in the human body, the value is increased by conditions such as fibrosis and calcification. The sound speed is usually high in elastic tissues and low in water. In the body, it is lowest in the fatty tissue. Ultrasound echoes are strong on the surface of bones which are hard and have a high sound speed. In organs filled with air such as the lungs, the bulk modulus is low and the sound speed is extremely low at 340 m/s, which produce strong echoes (the sound speed in solid tissues is 1,530 m/s). Human tissue is constructed of units smaller than the ultrasonic beam, and it is necessary to understand back-scattering in order to understand the ultrasonic images of these tissues. When ultrasound passes through tissue, it is absorbed as thermal energy and attenuated. Fiber is a tissue with a high absorption and attenuation rate. When the rate increases, the posterior echoes are attenuated. However, in masses with a high water content such as cysts, the posterior echoes are accentuated. This phenomenon is an important, basic finding for determining the properties of tumors. Breast cancer can be classified into two types: stellate carcinoma and circumscribed carcinoma. Since stellate carcinoma is rich in fiber, the posterior echoes are attenuated or lacking. However, circumscribed carcinoma has a high cellularity and the posterior echoes are accentuated. The same tendency is also seen in benign tumors. In immature fibroadenomas, posterior echoes are accentuated, while in fibroadenomas with hyalinosis, the posterior echoes are attenuated. Therefore, if the fundamentals of this tissue characterization and the histological features are understood, reading of ultrasound becomes easy. Color Doppler has also been developed and has contributed

  20. Ultrasound of the Thyroid Gland

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Thyroid Thyroid ultrasound uses sound waves to produce ... of Ultrasound of the Thyroid? What is an Ultrasound of the Thyroid? Ultrasound is safe and painless, ...

  1. Mount Rainier, a decade volcano

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, S.C.; Hooper, P.R. (Washington State Univ., Pullman, WA (United States). Dept. of Geology); Eggers, A.E. (Univ. of Puget Sound, Tacoma, WA (United States). Dept. of Geology)

    1993-04-01

    Mount Rainier, recently designated as a decade volcano, is a 14,410 foot landmark which towers over the heavily populated southern Puget Sound Lowland of Washington State. It last erupted in the mid-1800's and is an obvious threat to this area, yet Rainier has received little detailed study. Previous work has divided Rainier into two distinct pre-glacial eruptive episodes and one post-glacial eruptive episode. In a pilot project, the authors analyzed 253 well-located samples from the volcano for 27 major and trace elements. Their objective is to test the value of chemical compositions as a tool in mapping the stratigraphy and understanding the eruptive history of the volcano which they regard as prerequisite to determining the petrogenesis and potential hazard of the volcano. The preliminary data demonstrates that variation between flows is significantly greater than intra-flow variation -- a necessary condition for stratigraphic use. Numerous flows or groups of flows can be distinguished chemically. It is also apparent from the small variation in Zr abundances and considerable variation in such ratios as Ba/Nb that fractional crystallization plays a subordinate role to some form of mixing process in the origin of the Mount Rainier lavas.

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  3. Method for Observing Intravascular BongHan Duct

    CERN Document Server

    Jiang, X; Shin, H; Lee, B; Choi, C; Soh, K; Cheun, B; Baik, K; Soh, K; Jiang, Xiaowen; Kim, Hee-kyeong; Shin, Hak-soo; Lee, Byong-chon; Choi, Chunho; Soh, Kyung-soon; Cheun, Byeung-soo; Baik, Ku-youn; Soh, Kwang-sup

    2002-01-01

    A method for observing intra blood vessel ducts which are threadlike bundle of tubules which form a part of the BongHan duct system. By injecting 10% dextrose solution at a vena femoralis one makes the intravascular BongHan duct thicker and stronger to be easily detectable after incision of vessels. The duct is semi-transparent, soft and elastic, and composed of smaller tubules whose diameters are of 10$\\mu$m order, which is in agreement with BongHan theory.

  4. Primary Intrarenal Neuroblastoma with Hypertension and Disseminated Intravascular Coagulation

    Directory of Open Access Journals (Sweden)

    Bibi Shahin Shamsian

    2013-01-01

    Full Text Available The primary intrarenal neuroblastoma (IRNB is a rare condition. Intrarenal neuroblastoma typically results from direct renal invasion from an adrenal neuroblastoma, but true intrarenal neuroblastoma originates either sequestered adrenal rests during the fetal life or intrarenal sympathetic ganglia. Clinical, radiological, and pathological correlation is very essential for diagnosis and appropriate management of this type of unusual cases. The distinction of this rare tumor from Wilms’ tumor is an important challenge since both tumors have major differences in prognostic and therapeutic response. We present a 3-year-old boy of primary intrarenal neuroblastoma with extensive abdominal and mediastinal mass, persistent hypertension, and disseminated intravascular coagulation (DIC.

  5. Histamine release and endothelial leakage from an intravascular contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, R.

    1981-04-01

    The endothelial injury produced by meglumine iodamide was studied in the rat aorta. A mixture of blood and contrast medium was more toxic to the endothelium than the pure contrast agent. This difference disappeared after premedication with antihistamine, which did not affect the injury produced by the pure contrast agent. Meglumine iodamide appears to cause a release of histamine from blood but not from the aortic endothelium nor from surrounding tissues in amounts demonstrable by this method. Leucocytes are a source of histamine after intravascular contrast medium administration.

  6. Removal of Chronic Intravascular Blood Clots using Liquid Plasma

    Science.gov (United States)

    Jung, Jae-Chul; Choi, Myeong; Koo, Il; Yu, Zengqi; Collins, George

    2011-10-01

    An electrical embolectomy device for removing chronic intravascular blood clots using liquid plasma under saline environment was demonstrated. We employed a proxy experimental blood clot model of deep vein thrombosis (DVT) and actual equine blood clot. Thermal damage to contiguous tissue and the collagen denaturing via the plasma irradiation were investigated by histological analysis using birefringence of the tissue and verified by FT-IR spectroscopic study, respectively, which showed the high removal rate up to 2 mm per minute at room temperature and small thermal damage less than 200 μm.

  7. Silent Intravascular Lymphoma Initially Manifesting as a Unilateral Adrenal Incidentaloma

    Directory of Open Access Journals (Sweden)

    Yoshiko Takahashi

    2012-01-01

    Full Text Available Intravascular large B-cell lymphoma (IVLBCL is a rare subtype of malignant lymphoma. Although the involvement of adrenal glands in IVLBCL is often observed, primary adrenal IVLBCL is rare. Most reported cases of adrenal IVLBCL showed bilateral lesions resulting in rapidly progressive adrenal failure and poor prognosis. Here, we report a case of slowly progressive primary adrenal IVLBCL manifesting initially with unilateral adrenal incidentaloma. This case is a silent IVLBCL and shows that the enlargement of both adrenal glands can be followed.

  8. Fiber-Laser-Based Ultrasound Sensor for Photoacoustic Imaging

    Science.gov (United States)

    Liang, Yizhi; Jin, Long; Wang, Lidai; Bai, Xue; Cheng, Linghao; Guan, Bai-Ou

    2017-01-01

    Photoacoustic imaging, especially for intravascular and endoscopic applications, requires ultrasound probes with miniature size and high sensitivity. In this paper, we present a new photoacoustic sensor based on a small-sized fiber laser. Incident ultrasound waves exert pressures on the optical fiber laser and induce harmonic vibrations of the fiber, which is detected by the frequency shift of the beating signal between the two orthogonal polarization modes in the fiber laser. This ultrasound sensor presents a noise-equivalent pressure of 40 Pa over a 50-MHz bandwidth. We demonstrate this new ultrasound sensor on an optical-resolution photoacoustic microscope. The axial and lateral resolutions are 48 μm and 3.3 μm. The field of view is up to 1.57 mm2. The sensor exhibits strong resistance to environmental perturbations, such as temperature changes, due to common-mode cancellation between the two orthogonal modes. The present fiber laser ultrasound sensor offers a new tool for all-optical photoacoustic imaging.

  9. Fiber-Laser-Based Ultrasound Sensor for Photoacoustic Imaging

    Science.gov (United States)

    Liang, Yizhi; Jin, Long; Wang, Lidai; Bai, Xue; Cheng, Linghao; Guan, Bai-Ou

    2017-01-01

    Photoacoustic imaging, especially for intravascular and endoscopic applications, requires ultrasound probes with miniature size and high sensitivity. In this paper, we present a new photoacoustic sensor based on a small-sized fiber laser. Incident ultrasound waves exert pressures on the optical fiber laser and induce harmonic vibrations of the fiber, which is detected by the frequency shift of the beating signal between the two orthogonal polarization modes in the fiber laser. This ultrasound sensor presents a noise-equivalent pressure of 40 Pa over a 50-MHz bandwidth. We demonstrate this new ultrasound sensor on an optical-resolution photoacoustic microscope. The axial and lateral resolutions are 48 μm and 3.3 μm. The field of view is up to 1.57 mm2. The sensor exhibits strong resistance to environmental perturbations, such as temperature changes, due to common-mode cancellation between the two orthogonal modes. The present fiber laser ultrasound sensor offers a new tool for all-optical photoacoustic imaging. PMID:28098201

  10. A short contemporary history of disseminated intravascular coagulation.

    Science.gov (United States)

    Levi, Marcel; van der Poll, Tom

    2014-11-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to a widespread deposition of fibrin in the circulation. There is ample experimental and pathological evidence that the fibrin deposition contributes to multiple organ failure. The massive and ongoing activation of coagulation may result in depletion of platelets and coagulation factors, which may cause bleeding (consumption coagulopathy). The syndrome of DIC is well known in the medical literature for centuries, although a more precise description of the underlying mechanisms had to await the 20th century. Initial ideas on a role of the contact activation system as the primary trigger for the systemic activation of coagulation as well as a presumed hyperfibrinolytic response in DIC have been found to be misconceptions. Experimental and clinical evidence now indicate that the initiation of coagulation in DIC is caused by tissue factor expression, which in combination with downregulated physiological anticoagulant pathways and impaired fibrinolysis leads to widespread fibrin deposition. In addition, an extensive bidirectional interaction between coagulation and inflammation may further contribute to the pathogenesis of DIC.

  11. [Disseminated intravascular coagulation. Case series and literature review].

    Science.gov (United States)

    Del Carpio-Orantes, Luis; García-Ortiz, Jorge José

    2014-01-01

    INTRODUCCIÓN: la coagulación intravascular diseminada es una entidad caracteriza por activación de la cascada de la coagulación y fibrinólisis endógena, que puede provocar la muerte. Nuestros objetivos fueron identificar la incidencia de coagulación intravascular diseminada, sus agentes etiológicos y la correlación entre la puntuación de la escala Apache II y la propuesta por la Sociedad Internacional de Trombosis y Hemostasia para el diagnóstico de esta entidad. MÉTODOS: estudio retrospectivo, observacional y descriptivo de pacientes atendidos en una unidad de cuidados intensivos en un periodo de 17 meses. Se analizó etiología, edad, sexo, conteo de plaquetas, coagulograma, niveles de fibrinógeno sérico y cuantificación del dímero D. Se calculó la puntuación de la escala propuesta por la Sociedad Internacional de Trombosis y Hemostasia y de la escala APACHE II.

  12. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  13. Thyroid Storm Complicated by Bicytopenia and Disseminated Intravascular Coagulation

    Science.gov (United States)

    Tokushima, Yoshinori; Sakanishi, Yuta; Nagae, Kou; Tokushima, Midori; Tago, Masaki; Tomonaga, Motosuke; Yoshioka, Tsuneaki; Hyakutake, Masaki; Sugioka, Takashi; Yamashita, Shu-ichi

    2014-01-01

    Patient: Male, 23 Final Diagnosis: Thyroid storm Symptoms: Delirium • diarrhea • fever • hypertension • hyperventilation • tachycardia • weight loss Medication: — Clinical Procedure: — Specialty: Endocrinology and Metabolic Objective: Unusual clinical course Background: The clinical presentation of thyroid storm includes fever, tachycardia, hypertension, and neurological abnormalities. It is a serious condition with a high mortality rate. Furthermore, some other complications affect the clinical course of thyroid storm. Although it is reported that prognosis is poor when thyroid storm is complicated by disseminated intravascular coagulation syndrome (DIC) and leukopenia, reports of such cases are rare. Case Report: A 23-year-old man presented with delirium, high pyrexia, diarrhea, and weight loss of 18 kg over 2 months. According to the criteria of Burch and Wartofsky, he was diagnosed with thyroid storm on the basis of his symptom-complex and laboratory data that confirmed the presence of hyperthyroidism. Investigations also found leukopenia, thrombocytopenia, and disseminated intravascular coagulation, all of which are very rare complications of thyroid storm. We successfully treated him with combined therapy including anti-thyroid medication, despite leukopenia. Conclusions: Early diagnosis and treatment are essential in ensuring a good outcome for patients with this rare combination of medical problems. PMID:25072662

  14. Aleutian Islands Coastal Resources Inventory and Environmental Sensitivity Maps: VOLCANOS (Volcano Points)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains point locations of active volcanoes as compiled by Motyka et al., 1993. Eighty-nine volcanoes with eruptive phases in the Quaternary are...

  15. Volcano Monitoring Using Google Earth

    Science.gov (United States)

    Bailey, J. E.; Dehn, J.; Webley, P.; Skoog, R.

    2006-12-01

    At the Alaska Volcano Observatory (AVO), Google Earth is being used as a visualization tool for operational satellite monitoring of the region's volcanoes. Through the abilities of the Keyhole Markup Language (KML) utilized by Google Earth, different datasets have been integrated into this virtual globe browser. Examples include the ability to browse thermal satellite image overlays with dynamic control, to look for signs of volcanic activity. Webcams can also be viewed interactively through the Google Earth interface to confirm current activity. Other applications include monitoring the location and status of instrumentation; near real-time plotting of earthquake hypocenters; mapping of new volcanic deposits; and animated models of ash plumes within Google Earth, created by a combination of ash dispersion modeling and 3D visualization packages. The globe also provides an ideal interface for displaying near real-time information on detected thermal anomalies or "hotspot"; pixels in satellite images with elevated brightness temperatures relative to the background temperature. The Geophysical Institute at the University of Alaska collects AVHRR (Advanced Very High Resolution Radiometer) and MODIS (Moderate Resolution Imaging Spectroradiometer) through its own receiving station. The automated processing that follows includes application of algorithms that search for hotspots close to volcano location, flagging those that meet certain criteria. Further automated routines generate folders of KML placemarkers, which are linked to Google Earth through the network link function. Downloadable KML files have been created to provide links to various data products for different volcanoes and past eruptions, and to demonstrate examples of the monitoring tools developed. These KML files will be made accessible through a new website that will become publicly available in December 2006.

  16. Modeling eruptions of Karymsky volcano

    OpenAIRE

    Ozerov, A.; Ispolatov, I.; Lees, J.

    2001-01-01

    A model is proposed to explain temporal patterns of activity in a class of periodically exploding Strombolian-type volcanos. These patterns include major events (explosions) which follow each other every 10-30 minutes and subsequent tremor with a typical period of 1 second. This two-periodic activity is thought to be caused by two distinct mechanisms of accumulation of the elastic energy in the moving magma column: compressibility of the magma in the lower conduit and viscoelastic response of...

  17. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  18. Earthquakes - Volcanoes (Causes and Forecast)

    Science.gov (United States)

    Tsiapas, E.

    2009-04-01

    EARTHQUAKES - VOLCANOES (CAUSES AND FORECAST) ELIAS TSIAPAS RESEARCHER NEA STYRA, EVIA,GREECE TEL.0302224041057 tsiapas@hol.gr The earthquakes are caused by large quantities of liquids (e.g. H2O, H2S, SO2, ect.) moving through lithosphere and pyrosphere (MOHO discontinuity) till they meet projections (mountains negative projections or projections coming from sinking lithosphere). The liquids are moved from West Eastward carried away by the pyrosphere because of differential speed of rotation of the pyrosphere by the lithosphere. With starting point an earthquake which was noticed at an area and from statistical studies, we know when, where and what rate an earthquake may be, which earthquake is caused by the same quantity of liquids, at the next east region. The forecast of an earthquake ceases to be valid if these components meet a crack in the lithosphere (e.g. limits of lithosphere plates) or a volcano crater. In this case the liquids come out into the atmosphere by the form of gasses carrying small quantities of lava with them (volcano explosion).

  19. Active Deformation of Etna Volcano Combing IFSAR and GPS data

    Science.gov (United States)

    Lundgren, Paul

    1997-01-01

    The surface deformation of an active volcano is an important indicator of its eruptive state and its hazard potential. Mount Etna volcano in Sicily is a very active volcano with well documented eruption episodes.

  20. Campgrounds in Hawaii Volcanoes National Park

    Data.gov (United States)

    National Park Service, Department of the Interior — This dataset provides campground locations in Hawaii Volcanoes National Park. Information about facilities, water availability, permit requirements and type of...