WorldWideScience

Sample records for voi counts vary

  1. Construction site Voice Operated Information System (VOIS) test

    Science.gov (United States)

    Lawrence, Debbie J.; Hettchen, William

    1991-01-01

    The Voice Activated Information System (VAIS), developed by USACERL, allows inspectors to verbally log on-site inspection reports on a hand held tape recorder. The tape is later processed by the VAIS, which enters the information into the system's database and produces a written report. The Voice Operated Information System (VOIS), developed by USACERL and Automated Sciences Group, through a ESACERL cooperative research and development agreement (CRDA), is an improved voice recognition system based on the concepts and function of the VAIS. To determine the applicability of the VOIS to Corps of Engineers construction projects, Technology Transfer Test Bad (T3B) funds were provided to the Corps of Engineers National Security Agency (NSA) Area Office (Fort Meade) to procure and implement the VOIS, and to train personnel in its use. This report summarizes the NSA application of the VOIS to quality assurance inspection of radio frequency shielding and to progress payment logs, and concludes that the VOIS is an easily implemented system that can offer improvements when applied to repetitive inspection procedures. Use of VOIS can save time during inspection, improve documentation storage, and provide flexible retrieval of stored information.

  2. Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study

    International Nuclear Information System (INIS)

    Chen Lingyun; Shaw, Chris C.; Altunbas, Mustafa C.; Lai, C.-J.; Liu Xinming; Han Tao; Wang Tianpeng; Yang, Wei T.; Whitman, Gary J.

    2008-01-01

    This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to

  3. The relationship of VOI threshold, volume and B/S on DISA images

    International Nuclear Information System (INIS)

    Song Liejing; Wang Mingming; Si Hongwei; Li Fei

    2011-01-01

    Objective: To explore the relationship of VOI threshold, Volume and B/S on DISA phantom images. Methods: Ten hollow spheres were placed in cylinder phantom. According to the B/S of 1 : 7, 1 : 5 and 1 : 4, 99m TcO 4- and 18 F-FDG was filled into the container and spheres simultaneously and separately. Images were acquired by DISA and SIDA protocol. Volume of interest (VOI) for each sphere was analyzed by threshold method and to fit expression individually for validating of the relationship. Results: The equation for the estimation of optimal threshold was as following Tm = d + c × Bm/(e + f × Vm) + b/Vm. In majority of data, the calculated threshold was in the 1% interval that optimal thresholds were really in. Those who were not in were at the lower or upper intervals. Conclusions: Both DISA and SIDA images, based o the relationship of VOI thresh- old. Volume and B/S and real volume, this method could accurately calculate optimal threshold with an error less than 1% for spheres whose volumes ranged from 3.3 to 30.8 ml. (authors)

  4. Cross-cultural adaptation of the Chilean version of the Voice Symptom Scale - VoiSS.

    Science.gov (United States)

    Ruston, Francisco Contreras; Moreti, Felipe; Vivero, Martín; Malebran, Celina; Behlau, Mara

    This research aims to accomplish the cross-cultural equivalence of the Chilean version of the VoiSS protocol through its cultural and linguistic adaptation. After the translation of the VoiSS protocol to Chilean Spanish by two bilingual speech therapists and its back translation to English, we compared the items of the original tool with the previous translated version. The existing discrepancies were modified by a consensus committee of five speech therapists and the translated version was entitled Escala de Sintomas Vocales - ESV, with 30 questions and five answers: "Never", "Occasionally", "Sometimes", "Most of the time", "Always". For cross-cultural equivalence, the protocol was applied to 15 individuals with vocal problems. In each question the option of "Not applicable" was added to the answer choices for identification of the questions not comprehended or not appropriate for the target population. Two individuals had difficulty answering two questions, which made it necessary to adapt the translation of only one of them. The modified ESV was applied to three individuals with vocal problems, and there were incomprehensible inappropriate questions for the Chilean culture. The ESV reflects the original English version, both in the number of questions and the limitations of the emotional and physical domains. There is now a cross-cultural equivalence of VoiSS in Chilean Spanish, titled ESV. The validation of the ESV for Chilean Spanish is ongoing. RESUMEN Este estudio tuvo como objetivo realizar la equivalencia cultural de la versión Chilena del protocolo Voice Symptom Scale - VoiSS por medio de su adaptación cultural y lingüística. Después de la traducción del VoiSS para el Español Chileno, por dos fonoaudiólogos bilingües, y de la retro traducción para el inglés, se realizó una comparación de los ítems del instrumento original con la versión traducida, surgiendo discrepancias; tales divergencias fueron resueltas por un comité compuesto por

  5. Estimating study costs for use in VOI, a study of dutch publicly funded drug related research

    NARCIS (Netherlands)

    Van Asselt, A.D.; Ramaekers, B.L.; Corro Ramos, I.; Joore, M.A.; Al, M.J.; Lesman-Leegte, I.; Postma, M.J.; Vemer, P.; Feenstra, T.F.

    2016-01-01

    Objectives: To perform value of information (VOI) analyses, an estimate of research costs is needed. However, reference values for such costs are not available. This study aimed to analyze empirical data on research budgets and, by means of a cost tool, provide an overview of costs of several types

  6. Two-Tier VoI Prioritization System on Requirement-Based Data Streaming toward IoT

    Directory of Open Access Journals (Sweden)

    Sunyanan Choochotkaew

    2017-01-01

    Full Text Available Toward the world of Internet of Things, people utilize knowledge from sensor streams in various kinds of smart applications. The number of sensing devices is rapidly increasing along with the amount of sensing data. Consequently, a bottleneck problem at the local gateway has attracted high concern. An example scenario is smart elderly houses in rural areas where each house installs thousands of sensors and all connect to resource-limited and unstable 2G/3G networks. The bottleneck state can incur unacceptable latency and loss of significant data due to the limited waiting-queue. Orthogonally to the existing solutions, we propose a two-tier prioritization system to enhance information quality, indicated by VoI, at the local gateway. The proposed system has been designed to support several requirements with several conflicting criteria over shared sensing streams. Our approach adopts Multicriteria Decision Analysis technique to merge requirements and to assess the VoI. We introduce the framework that can reduce the computational cost by precalculation. Through a case study of building management systems, we have shown that our merge algorithm can provide 0.995 cosine-similarity for representing all user requirements and the evaluation approach can obtain satisfaction values around 3 times higher than the naïve strategies for the top-list data.

  7. SPAM-assisted partial volume correction algorithm for PET

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2000-07-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38{+-}6%, while those of hippocampus and amygdala by 4{+-}3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images.

  8. SPAM-assisted partial volume correction algorithm for PET

    International Nuclear Information System (INIS)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul

    2000-01-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38±6%, while those of hippocampus and amygdala by 4±3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images

  9. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  10. Evaluation of elastix-based propagated align algorithm for VOI- and voxel-based analysis of longitudinal F-18-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC)

    OpenAIRE

    Kerner, Gerald S. M. A.; Fischer, Alexander; Koole, Michel J. B.; Pruim, Jan; Groen, Harry J. M.

    2015-01-01

    Background: Deformable image registration allows volume of interest (VOI)- and voxel-based analysis of longitudinal changes in fluorodeoxyglucose (FDG) tumor uptake in patients with non-small cell lung cancer (NSCLC). This study evaluates the performance of the elastix toolbox deformable image registration algorithm for VOI and voxel-wise assessment of longitudinal variations in FDG tumor uptake in NSCLC patients. Methods: Evaluation of the elastix toolbox was performed using F-18-FDG PET/CT ...

  11. Les kystes hydatiques du foie rompus dans les voies biliaires: à propos de 120 cas

    Science.gov (United States)

    Moujahid, Mountassir; Tajdine, Mohamed Tarik

    2011-01-01

    Etude rétrospective rapportant une série de kystes hydatiques rompus dans les voies biliaires colligés dans le service de chirurgie de l'hôpital militaire Avicenne à Marrakech. Entre 1990 à 2008, sur 536 kystes hydatiques du foie opérés dans le service, 120 étaient compliqués de rupture dans les voies biliaires soit 22,38%. Il y avait 82hommes et 38 femmes. L’âge moyen était de 35 ans avec des extrêmes allant de 10 à 60 ans. La clinique était dominée par la crise d'angiocholite ou une douleur du flanc droit. L'ictère était isolé dans huit cas. La fistule biliokystique était latente dans plus de 50% des cas. Le traitement a consisté en une résection du dôme saillant dans103cas (85,84%), une périkystectomie chez 11 malades (9,16%) et une lobectomie gauche dans six cas (5%). Le traitement de la fistule bilio kystique a consisté en une suture chez 36malades et un drainage bipolaire dans 25 cas, La déconnexion kysto-biliaire ou cholédocotomie trans hépatico kystique selon Perdomo était pratiquée dans 49cas et une anastomose bilio-digestive cholédoco-duodénale dans 10 cas. La durée moyenne d'hospitalisation était de 20jours. Nous déplorons deux décès par choc septique et un troisième par encéphalopathie secondaire à une cirrhose biliaire. La morbidité était représentée par huit abcès sous phrénique, douze fistules biliaires prolongées et deux occlusions intestinales. Les kystes hydatiques rompus dans les voies biliaires représentent la complication la plus grave de cette pathologie bénigne. Le traitement repose sur des méthodes radicales qui sont d'une efficacité reconnue, mais de réalisation dangereuse et les méthodes conservatrices, en particulier la déconnexion kysto-biliaire qui est une méthode simple et qui donne de bons résultats à court et à long terme. PMID:22384289

  12. Quantification of 18F-FDG PET images using probabilistic brain atlas: clinical application in temporal lobe epilepsy patients

    International Nuclear Information System (INIS)

    Kang, Keon Wook; Lee, Dong Soo; Cho, Jae Hoon; Lee, Jae Sung; Yeo, Jeong Seok; Lee, Sang Gun; Chung, June Key; Lee, Myung Chul

    2000-01-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the international consortium for brain mapping (ICBM). After calculating the counts in volume of interest (VOI) using the product of probability of SPAM images and counts in FDG images, asymmetric indexes(AI) were calculated and used for finding epileptogenic zones in temporal lobe epilepsy (TLE). FDG PET images from 28 surgically confirmed TLE patients and 12 age-matched controls were spatially normalized to the averaged brain MRI atlas of ICBM. The counts from normalized PET images were multiplied with the probability of 12 VOIs (superior temporal gyrus, middle temporal gyrus, inferior temporal gyrus, hippocampus, parahippocampal gyrus, and amygdala in each hemisphere) of SPAM images of Montreal Neurological Institute. Finally AI was calculated on each pair of VOI, and compared with visual assessment. If AI was deviated more than 2 standard deviation of normal controls, we considered epileptogenic zones were found successfully. The counts of VOIs in normal controls were symmetric (AI 0.05) except those of inferior temporal gyrus (p<0.01). AIs in 5 pairs of VOI excluding inferior temporal gyrus were deviated to one side in TLE (p<0.05). Lateralization was correct in 23/28 of patients by AI, but all of 28 were consistent with visual inspection. In 3 patients with normal AI was symmetric on visual inspection. In 2 patients falsely lateralized using AI, metabolism was also decreased visually on contra-lateral side. Asymmetric index obtained by the product of statistical probability anatomical map and FDG PET correlated well with visual assessment in TLE patients. SPAM is useful for quantification of VOIs in functional images

  13. Identification d’une nouvelle molécule d’intérêt chez le cheval atteint d’obstruction récurrente des voies respiratoires: La Pentraxine 3

    OpenAIRE

    Ramery, Eve

    2010-01-01

    L’ORVR ou obstruction récurrente des voies respiratoires (ORVR) est la cause la plus fréquente de maladie pulmonaire chronique chez le cheval adulte. La maladie se caractérise par une hyperréactivité bronchique, une production excessive de mucus et une inflammation neutrophilique pulmonaire qui ont pour effet de réduire la compliance dynamique du poumon et d’augmenter la résistance des voies respiratoires au débit aérien. Alors que la maladie est une entité documentée dans la littérature depu...

  14. On-line statistical processing of radiation detector pulse trains with time-varying count rates

    International Nuclear Information System (INIS)

    Apostolopoulos, G.

    2008-01-01

    Statistical analysis is of primary importance for the correct interpretation of nuclear measurements, due to the inherent random nature of radioactive decay processes. This paper discusses the application of statistical signal processing techniques to the random pulse trains generated by radiation detectors. The aims of the presented algorithms are: (i) continuous, on-line estimation of the underlying time-varying count rate θ(t) and its first-order derivative dθ/dt; (ii) detection of abrupt changes in both of these quantities and estimation of their new value after the change point. Maximum-likelihood techniques, based on the Poisson probability distribution, are employed for the on-line estimation of θ and dθ/dt. Detection of abrupt changes is achieved on the basis of the generalized likelihood ratio statistical test. The properties of the proposed algorithms are evaluated by extensive simulations and possible applications for on-line radiation monitoring are discussed

  15. Quantification of {sup 18}F-FDG PET images using probabilistic brain atlas: clinical application in temporal lobe epilepsy patients

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Keon Wook; Lee, Dong Soo; Cho, Jae Hoon; Lee, Jae Sung; Yeo, Jeong Seok; Lee, Sang Gun; Chung, June Key; Lee, Myung Chul [Seoul National Univ., Seoul (Korea, Republic of)

    2000-07-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the international consortium for brain mapping (ICBM). After calculating the counts in volume of interest (VOI) using the product of probability of SPAM images and counts in FDG images, asymmetric indexes(AI) were calculated and used for finding epileptogenic zones in temporal lobe epilepsy (TLE). FDG PET images from 28 surgically confirmed TLE patients and 12 age-matched controls were spatially normalized to the averaged brain MRI atlas of ICBM. The counts from normalized PET images were multiplied with the probability of 12 VOIs (superior temporal gyrus, middle temporal gyrus, inferior temporal gyrus, hippocampus, parahippocampal gyrus, and amygdala in each hemisphere) of SPAM images of Montreal Neurological Institute. Finally AI was calculated on each pair of VOI, and compared with visual assessment. If AI was deviated more than 2 standard deviation of normal controls, we considered epileptogenic zones were found successfully. The counts of VOIs in normal controls were symmetric (AI <6%, paired t-test p>0.05) except those of inferior temporal gyrus (p<0.01). AIs in 5 pairs of VOI excluding inferior temporal gyrus were deviated to one side in TLE (p<0.05). Lateralization was correct in 23/28 of patients by AI, but all of 28 were consistent with visual inspection. In 3 patients with normal AI was symmetric on visual inspection. In 2 patients falsely lateralized using AI, metabolism was also decreased visually on contra-lateral side. Asymmetric index obtained by the product of statistical probability anatomical map and FDG PET correlated well with visual assessment in TLE patients. SPAM is useful for quantification of VOIs in functional images.

  16. Under which conditions, additional monitoring data are worth gathering for improving decision making? Application of the VOI theory in the Bayesian Event Tree eruption forecasting framework

    Science.gov (United States)

    Loschetter, Annick; Rohmer, Jérémy

    2016-04-01

    Standard and new generation of monitoring observations provide in almost real-time important information about the evolution of the volcanic system. These observations are used to update the model and contribute to a better hazard assessment and to support decision making concerning potential evacuation. The framework BET_EF (based on Bayesian Event Tree) developed by INGV enables dealing with the integration of information from monitoring with the prospect of decision making. Using this framework, the objectives of the present work are i. to propose a method to assess the added value of information (within the Value Of Information (VOI) theory) from monitoring; ii. to perform sensitivity analysis on the different parameters that influence the VOI from monitoring. VOI consists in assessing the possible increase in expected value provided by gathering information, for instance through monitoring. Basically, the VOI is the difference between the value with information and the value without additional information in a Cost-Benefit approach. This theory is well suited to deal with situations that can be represented in the form of a decision tree such as the BET_EF tool. Reference values and ranges of variation (for sensitivity analysis) were defined for input parameters, based on data from the MESIMEX exercise (performed at Vesuvio volcano in 2006). Complementary methods for sensitivity analyses were implemented: local, global using Sobol' indices and regional using Contribution to Sample Mean and Variance plots. The results (specific to the case considered) obtained with the different techniques are in good agreement and enable answering the following questions: i. Which characteristics of monitoring are important for early warning (reliability)? ii. How do experts' opinions influence the hazard assessment and thus the decision? Concerning the characteristics of monitoring, the more influent parameters are the means rather than the variances for the case considered

  17. ”EI OIKEASSA ELÄMÄSSÄ VOI JUOSTA MIEKKA OJOSSA LOHIKÄÄRMETTÄ KOHTI”: Digipelaajien kokemus omasta hyvinvoinnistaan

    OpenAIRE

    Engström, Paula

    2016-01-01

    Paula Engström. ”Ei oikeassa elämässä voi juosta miekka ojossa lohikäärmettä kohti”: Digipelaajien kokemus omasta hyvinvoinnistaan. Diak Etelä, Helsinki, syksy 2016, 57s., 1 liite. Diakonia-ammattikorkeakoulu, Sosiaalialan koulutusohjelma, sosionomi (AMK). Opinnäytetyön aihe syntyi Ehkäisevä päihdetyö EHYT ry:n toiveista saada kooste vuonna 2015 toteutetun Pelaajien hyvinvointikyselyn tuloksista. Opinnäytetyön tavoitteena oli saada selville, miten digitaalisia pelejä harrastavat nuor...

  18. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  19. Evaluation of elastix-based propagated align algorithm for VOI- and voxel-based analysis of longitudinal F-18-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC)

    NARCIS (Netherlands)

    Kerner, Gerald S. M. A.; Fischer, Alexander; Koole, Michel J. B.; Pruim, Jan; Groen, Harry J. M.

    2015-01-01

    Background: Deformable image registration allows volume of interest (VOI)- and voxel-based analysis of longitudinal changes in fluorodeoxyglucose (FDG) tumor uptake in patients with non-small cell lung cancer (NSCLC). This study evaluates the performance of the elastix toolbox deformable image

  20. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  1. Radiation Counting System Software Using Visual Basic

    International Nuclear Information System (INIS)

    Nanda Nagara; Didi Gayani

    2009-01-01

    It has been created a Gamma Radiation Counting System using interface card, which paired with Personal Computer (PC) and operated by the Visual Basic program. The program was set through varied menu selections such as ”Multi Counting” , ”Counting and Record” and ”View Data”. An interface card for data acquisition was formed by using AMD9513 components as a counter and timer which can be programmed. This counting system was tested and used in waste facility in PTNBR and the result is quite good. (author)

  2. Color quench correction for low level Cherenkov counting.

    Science.gov (United States)

    Tsroya, S; Pelled, O; German, U; Marco, R; Katorza, E; Alfassi, Z B

    2009-05-01

    The Cherenkov counting efficiency varies strongly with color quenching, thus correction curves must be used to obtain correct results. The external (152)Eu source of a Quantulus 1220 liquid scintillation counting (LSC) system was used to obtain a quench indicative parameter based on spectra area ratio. A color quench correction curve for aqueous samples containing (90)Sr/(90)Y was prepared. The main advantage of this method over the common spectra indicators is its usefulness also for low level Cherenkov counting.

  3. Development of a stained cell nuclei counting system

    Science.gov (United States)

    Timilsina, Niranjan; Moffatt, Christopher; Okada, Kazunori

    2011-03-01

    This paper presents a novel cell counting system which exploits the Fast Radial Symmetry Transformation (FRST) algorithm [1]. The driving force behind our system is a research on neurogenesis in the intact nervous system of Manduca Sexta or the Tobacco Hornworm, which was being studied to assess the impact of age, food and environment on neurogenesis. The varying thickness of the intact nervous system in this species often yields images with inhomogeneous background and inconsistencies such as varying illumination, variable contrast, and irregular cell size. For automated counting, such inhomogeneity and inconsistencies must be addressed, which no existing work has done successfully. Thus, our goal is to devise a new cell counting algorithm for the images with non-uniform background. Our solution adapts FRST: a computer vision algorithm which is designed to detect points of interest on circular regions such as human eyes. This algorithm enhances the occurrences of the stained-cell nuclei in 2D digital images and negates the problems caused by their inhomogeneity. Besides FRST, our algorithm employs standard image processing methods, such as mathematical morphology and connected component analysis. We have evaluated the developed cell counting system with fourteen digital images of Tobacco Hornworm's nervous system collected for this study with ground-truth cell counts by biology experts. Experimental results show that our system has a minimum error of 1.41% and mean error of 16.68% which is at least forty-four percent better than the algorithm without FRST.

  4. Liquid scintillation: Sample preparation and counting atypical emissions

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Liquid scintillation sample preparation has the most published information but the least amount of definitive technical direction because the chemical and physical nature of the samples from biological investigations varies widely. This chapter discusses the following related topics: Aqueous Samples; Tissue Solubilizers; Absorption of 14 CO 2 ; Sample Combustion Methods; Heterogeneous Systems; Sample Preparation Problems (colored samples, chemiluminescence, photoluminescence, static electricity); Counting Various Types of Emitters; Counting Atypical Emissions. 2 refs., 2 figs

  5. Correct liquid scintillation counting of steroids and glycosides in RIA samples: a comparison of xylene-based, dioxane-based and colloidal counting systems. Chapter 14

    International Nuclear Information System (INIS)

    Spolders, H.

    1977-01-01

    In RIA, the following parameters are important for accurate liquid scintillation counting. (1) Absence of chemiluminescence. (2) Stability of count rate. (3) Dissolving properties for the sample. For samples with varying colours, a quench correction must be applied. For any type of accurate quench correction, a homogeneous sample is necessary. This can be obtained if proteins and the buffer can be dissolved completely in the scintillator solution. In this paper, these criteria are compared in xylene-based, dioxane-based and colloidal scintillation solutions for either bound or free antigens of different polarity. The labelling radioisotope used was 3 H. Using colloidal scintillators with plasma and buffer samples, phasing or sedimentation of salt or proteins sometimes occurs. The influence of sedimentation or phasing on count rate stability and correct quench correction is illustrated by varying the ratio between the scintillator solution and a RIA sample containing a semi-polar steroid aldosterone. (author)

  6. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  7. A study of cellular counting to determine minimum thresholds for adequacy for liquid-based cervical cytology using a survey and counting protocol.

    Science.gov (United States)

    Kitchener, Henry C; Gittins, Matthew; Desai, Mina; Smith, John H F; Cook, Gary; Roberts, Chris; Turnbull, Lesley

    2015-03-01

    Liquid-based cytology (LBC) for cervical screening would benefit from laboratory practice guidelines that define specimen adequacy for reporting of slides. The evidence base required to define cell adequacy should incorporate both ThinPrep™ (TP; Hologic, Inc., Bedford, MA, USA) and SurePath™ (SP; BD Diagnostics, Burlington, NC, USA), the two LBC systems used in the UK cervical screening programmes. The objectives of this study were to determine (1) current practice for reporting LBC in England, Wales and Scotland, (2) a reproducible method for cell counting, (3) the cellularity of slides classified as inadequate, negative or abnormal and (4) the impact of varying cellularity on the likelihood of detecting cytological abnormalities. The study involved four separate arms to pursue each of the four objectives. (1) A questionnaire survey of laboratories was conducted. (2) A standard counting protocol was developed and used by three experienced cytopathologists to determine a reliable and reproducible cell counting method. (3) Slide sets which included a range of cytological abnormalities were each sent to three laboratories for cell counting to study the correlation between cell counts and reported cytological outcomes. (4) Dilution of LBC samples by fluid only (unmixed) or by dilution with a sample containing normal cells (mixed) was performed to study the impact on reporting of reducing either the total cell count or the relative proportion of abnormal to normal cells. The study was conducted within the cervical screening programmes in England, Wales and Scotland, using routinely obtained cervical screening samples, and in 56 participating NHS cervical cytology laboratories. The study involved only routinely obtained cervical screening samples. There was no clinical intervention. The main outcome measures were (1) reliability of counting method, (2) correlation of reported cytology grades with cellularity and (3) levels of detection of abnormal cells in

  8. Metabolic connectivity by interregional correlation analysis using statistical parametric mapping (SPM) and FDG brain PET; methodological development and patterns of metabolic connectivity in adults

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Oh, Jungsu S.; Lee, Jae Sung; Lee, Myung Chul; Kang, Hyejin; Kim, Heejung; Park, Hyojin

    2008-01-01

    Regionally connected areas of the resting brain can be detected by fluorodeoxyglucose-positron emission tomography (FDG-PET). Voxel-wise metabolic connectivity was examined, and normative data were established by performing interregional correlation analysis on statistical parametric mapping of FDG-PET data. Characteristics of seed volumes of interest (VOIs) as functional brain units were represented by their locations, sizes, and the independent methods of their determination. Seed brain areas were identified as population-based gyral VOIs (n=70) or as population-based cytoarchitectonic Brodmann areas (BA; n=28). FDG uptakes in these areas were used as independent variables in a general linear model to search for voxels correlated with average seed VOI counts. Positive correlations were searched in entire brain areas. In normal adults, one third of gyral VOIs yielded correlations that were confined to themselves, but in the others, correlated voxels extended to adjacent areas and/or contralateral homologous regions. In tens of these latter areas with extensive connectivity, correlated voxels were found across midline, and asymmetry was observed in the patterns of connectivity of left and right homologous seed VOIs. Most of the available BAs yielded correlations reaching contralateral homologous regions and/or neighboring areas. Extents of metabolic connectivity were not found to be related to seed VOI size or to the methods used to define seed VOIs. These findings indicate that patterns of metabolic connectivity of functional brain units depend on their regional locations. We propose that interregional correlation analysis of FDG-PET data offers a means of examining voxel-wise regional metabolic connectivity of the resting human brain. (orig.)

  9. Metabolic connectivity by interregional correlation analysis using statistical parametric mapping (SPM) and FDG brain PET; methodological development and patterns of metabolic connectivity in adults

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Soo; Oh, Jungsu S.; Lee, Jae Sung; Lee, Myung Chul [Seoul National University, College of Medicine, Department of Nuclear Medicine, Jongno-gu, Seoul (Korea); Kang, Hyejin [Seoul National University, College of Medicine, Department of Nuclear Medicine, Jongno-gu, Seoul (Korea); Seoul National University, Programs in Brain and Neuroscience, Seoul (Korea); Kim, Heejung; Park, Hyojin [Seoul National University, College of Medicine, Department of Nuclear Medicine, Jongno-gu, Seoul (Korea); Seoul National University, Interdisciplinary Program in Cognitive Science, Seoul (Korea)

    2008-09-15

    Regionally connected areas of the resting brain can be detected by fluorodeoxyglucose-positron emission tomography (FDG-PET). Voxel-wise metabolic connectivity was examined, and normative data were established by performing interregional correlation analysis on statistical parametric mapping of FDG-PET data. Characteristics of seed volumes of interest (VOIs) as functional brain units were represented by their locations, sizes, and the independent methods of their determination. Seed brain areas were identified as population-based gyral VOIs (n=70) or as population-based cytoarchitectonic Brodmann areas (BA; n=28). FDG uptakes in these areas were used as independent variables in a general linear model to search for voxels correlated with average seed VOI counts. Positive correlations were searched in entire brain areas. In normal adults, one third of gyral VOIs yielded correlations that were confined to themselves, but in the others, correlated voxels extended to adjacent areas and/or contralateral homologous regions. In tens of these latter areas with extensive connectivity, correlated voxels were found across midline, and asymmetry was observed in the patterns of connectivity of left and right homologous seed VOIs. Most of the available BAs yielded correlations reaching contralateral homologous regions and/or neighboring areas. Extents of metabolic connectivity were not found to be related to seed VOI size or to the methods used to define seed VOIs. These findings indicate that patterns of metabolic connectivity of functional brain units depend on their regional locations. We propose that interregional correlation analysis of FDG-PET data offers a means of examining voxel-wise regional metabolic connectivity of the resting human brain. (orig.)

  10. Steps Counts among Middle School Students Vary with Aerobic Fitness Level

    Science.gov (United States)

    Le Masurier, Guy C.; Corbin, Charles B.

    2006-01-01

    The purpose of this study was to examine if steps/day taken by middle school students varied based on aerobic fitness classification. Middle school students (N = 223; 112 girls, 111 boys) were assigned to three aerobic fitness categories (HIGH, MOD, LOW) based on results of the FITNESSGRAM PACER test. Four weekdays of pedometer monitoring…

  11. High rate 4π β-γ coincidence counting system

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gehrke, R.J.

    1978-01-01

    A high count rate 4π β-γ coincidence counting system for the determination of absolute disintegration rates of short half-life radionuclides is described. With this system the dead time per pulse is minimized by not stretching any pulses beyond the width necessary to satisfy overlap coincidence requirements. The equations used to correct for the β, γ, and coincidence channel dead times and for accidental coincidences are presented but not rigorously developed. Experimental results are presented for a decaying source of 56 Mn initially at 2 x 10 6 d/s and a set of 60 Co sources of accurately known source strengths varying from 10 3 to 2 x 10 6 d/s. A check of the accidental coincidence equation for the case of two independent sources with varying source strengths is presented

  12. Automatic quench compensation for liquid scintillation counting system

    International Nuclear Information System (INIS)

    Nather, R.E.

    1978-01-01

    A method of automatic quench compensation is provided, where a reference measure of quench is taken on a sample prior to taking a sample count. The measure of quench is then compared with a reference voltage source which has been established to vary in proportion to the variation of the measure of quench with the level of a system parameter required to restore at least one isotope spectral energy endpoint substantially to a selected counting window discriminator level in order to determine the amount of adjustment of the system parameter required to restore the endpoint. This is followed by the appropriate adjustment of the system parameter required to restore the relative position of the discriminator windows and the sample spectrum and is followed in turn by taking a sample count

  13. VoiLA: A multidisciplinary study of Volatile recycling in the Lesser Antilles Arc

    Science.gov (United States)

    Collier, J.; Blundy, J. D.; Goes, S. D. B.; Henstock, T.; Harmon, N.; Kendall, J. M.; Macpherson, C.; Rietbrock, A.; Rychert, C.; Van Hunen, J.; Wilkinson, J.; Wilson, M.

    2017-12-01

    Project VoiLA will address the role of volatiles in controlling geological processes at subduction zones. The study area was chosen as it subducts oceanic lithosphere formed at the slow-spreading Mid Atlantic Ridge. This should result in a different level and pattern of hydration to compare with subduction zones in the Pacific which consume oceanic lithosphere generated at faster spreading rates. In five project components, we will test (1) where volatiles are held within the incoming plate; (2) where they are transported and released below the arc; (3) how the volatile distribution and pathways relate to the construction of the arc; and (4) their relationship to seismic and volcanic hazards and the fractionation of economic metals. Finally, (5) the behaviour of the Lesser Antilles arc will be compared with that of other well-studied systems to improve our wider understanding of the role of water in subduction processes. To address these questions the project will combine seismology; petrology and numerical modelling of wedge dynamics and its consequences on dehydration and melting. So-far island-based fieldwork has included mantle xenolith collection and installation of a temporary seismometer network. In 2016 and 2017 we conducted cruises onboard the RRS James Cook that collected a network of passive-recording and active-recording ocean-bottom seismometer data within the back-arc, fore-arc and incoming plate region. A total of 175 deployments and recoveries were made with the loss of only 6 stations. The presentation will present preliminary results from the project.

  14. Effects of computing parameters and measurement locations on the estimation of 3D NPS in non-stationary MDCT images.

    Science.gov (United States)

    Miéville, Frédéric A; Bolard, Gregory; Bulling, Shelley; Gudinchet, François; Bochud, François O; Verdun, François R

    2013-11-01

    The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT. Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Realization of fluence field modulated CT on a clinical TomoTherapy megavoltage CT system

    International Nuclear Information System (INIS)

    Szczykutowicz, Timothy P; Hermus, James; Geurts, Mark; Smilowitz, Jennifer

    2015-01-01

    The multi-leaf collimator (MLC) assembly present on TomoTherapy (Accuray, Madison WI) radiation therapy (RT) and mega voltage CT machines is well suited to perform fluence field modulated CT (FFMCT). In addition, there is a demand in the RT environment for FFMCT imaging techniques, specifically volume of interest (VOI) imaging.A clinical TomoTherapy machine was programmed to perform VOI. Four different size ROIs were placed at varying distances from isocenter. Projections intersecting the VOI received ‘full dose’ while those not intersecting the VOI received 30% of the dose (i.e. the incident fluence for non VOI projections was 30% of the incident fluence for projections intersecting the VOI). Additional scans without fluence field modulation were acquired at ‘full’ and 30% dose. The noise (pixel standard deviation) and mean CT number were measured inside the VOI region and compared between the three scans. Dose maps were generated using a dedicated TomoTherapy treatment planning dose calculator.The VOI-FFMCT technique produced an image noise 1.05, 1.00, 1.03, and 1.05 times higher than the ‘full dose’ scan for ROI sizes of 10 cm, 13 cm, 10 cm, and 6 cm respectively within the VOI region. The VOI-FFMCT technique required a total imaging dose equal to 0.61, 0.69, 0.60, and 0.50 times the ‘full dose’ acquisition dose for ROI sizes of 10 cm, 13 cm, 10 cm, and 6 cm respectively within the VOI region.Noise levels can be almost unchanged within clinically relevant VOIs sizes for RT applications while the integral imaging dose to the patient can be decreased, and/or the image quality in RT can be dramatically increased with no change in dose relative to non-FFMCT RT imaging. The ability to shift dose away from regions unimportant for clinical evaluation in order to improve image quality or reduce imaging dose has been demonstrated. This paper demonstrates that FFMCT can be performed using the MLC on a clinical TomoTherapy machine for the

  16. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  17. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  18. Set of counts by scintillations for atmospheric samplings; Ensemble de comptages par scintillations pour prelevements atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Appriou, D.; Doury, A.

    1962-07-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies.

  19. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  20. More accurate thermal neutron coincidence counting technique

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    Using passive thermal neutron coincidence counting techniques, the accuracy of nondestructive assays of fertile material can be improved significantly using a two-ring detector. It was shown how the use of a function of the coincidence count rate ring-ratio can provide a detector response rate that is independent of variations in neutron detection efficiency caused by varying sample moderation. Furthermore, the correction for multiplication caused by SF- and (α,n)-neutrons is shown to be separable into the product of a function of the effective mass of 240 Pu (plutonium correction) and a function of the (α,n) reaction probability (matrix correction). The matrix correction is described by a function of the singles count rate ring-ratio. This correction factor is empirically observed to be identical for any combination of PuO 2 powder and matrix materials SiO 2 and MgO because of the similar relation of the (α,n)-Q value and (α,n)-reaction cross section among these matrix nuclei. However the matrix correction expression is expected to be different for matrix materials such as Na, Al, and/or Li. Nevertheless, it should be recognized that for comparison measurements among samples of similar matrix content, it is expected that some function of the singles count rate ring-ratio can be defined to account for variations in the matrix correction due to differences in the intimacy of mixture among the samples. Furthermore the magnitude of this singles count rate ring-ratio serves to identify the contaminant generating the (α,n)-neutrons. Such information is useful in process control

  1. Effect of varying concentrations of orally ingested glucose on platelet ...

    African Journals Online (AJOL)

    The physiologic basis of bleeding is a function of normal platelets and coagulation factors. This study is aimed at ascertaining the effect of varying concentrations of orally ingested glucose on platelet count and hemoglobin concentration during menstruation. Forty menstruating students between the ages of 18 and 25 from ...

  2. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  3. Road safety performance measures and AADT uncertainty from short-term counts.

    Science.gov (United States)

    Milligan, Craig; Montufar, Jeannette; Regehr, Jonathan; Ghanney, Bartholomew

    2016-12-01

    The objective of this paper is to enable better risk analysis of road safety performance measures by creating the first knowledge base on uncertainty surrounding annual average daily traffic (AADT) estimates when the estimates are derived by expanding short-term counts with the individual permanent counter method. Many road safety performance measures and performance models use AADT as an input. While there is an awareness that the input suffers from uncertainty, the uncertainty is not well known or accounted for. The paper samples data from a set of 69 permanent automatic traffic recorders in Manitoba, Canada, to simulate almost 2 million short-term counts over a five year period. These short-term counts are expanded to AADT estimates by transferring temporal information from a directly linked nearby permanent count control station, and the resulting AADT values are compared to a known reference AADT to compute errors. The impacts of five factors on AADT error are considered: length of short-term count, number of short-term counts, use of weekday versus weekend counts, distance from a count to its expansion control station, and the AADT at the count site. The mean absolute transfer error for expanded AADT estimates is 6.7%, and this value varied by traffic pattern group from 5% to 10.5%. Reference percentiles of the error distribution show that almost all errors are between -20% and +30%. Error decreases substantially by using a 48-h count instead of a 24-h count, and only slightly by using two counts instead of one. Weekday counts are superior to weekend counts, especially if the count is only 24h. Mean absolute transfer error increases with distance to control station (elasticity 0.121, p=0.001), and increases with AADT (elasticity 0.857, proad safety performance measures that use AADT as inputs. Analytical frameworks for such analysis exist but are infrequently used in road safety because the evidence base on AADT uncertainty is not well developed. Copyright

  4. Bioassay method for Uranium in urine by Delay Neutron counting

    International Nuclear Information System (INIS)

    Suratman; Purwanto; Sukarman-Aminjoyo

    1996-01-01

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 μg

  5. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  6. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  7. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  8. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  9. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  10. Temporal aggregation of migration counts can improve accuracy and precision of trends

    Directory of Open Access Journals (Sweden)

    Tara L. Crewe

    2016-12-01

    Full Text Available Temporal replicate counts are often aggregated to improve model fit by reducing zero-inflation and count variability, and in the case of migration counts collected hourly throughout a migration, allows one to ignore nonindependence. However, aggregation can represent a loss of potentially useful information on the hourly or seasonal distribution of counts, which might impact our ability to estimate reliable trends. We simulated 20-year hourly raptor migration count datasets with known rate of change to test the effect of aggregating hourly counts to daily or annual totals on our ability to recover known trend. We simulated data for three types of species, to test whether results varied with species abundance or migration strategy: a commonly detected species, e.g., Northern Harrier, Circus cyaneus; a rarely detected species, e.g., Peregrine Falcon, Falco peregrinus; and a species typically counted in large aggregations with overdispersed counts, e.g., Broad-winged Hawk, Buteo platypterus. We compared accuracy and precision of estimated trends across species and count types (hourly/daily/annual using hierarchical models that assumed a Poisson, negative binomial (NB or zero-inflated negative binomial (ZINB count distribution. We found little benefit of modeling zero-inflation or of modeling the hourly distribution of migration counts. For the rare species, trends analyzed using daily totals and an NB or ZINB data distribution resulted in a higher probability of detecting an accurate and precise trend. In contrast, trends of the common and overdispersed species benefited from aggregation to annual totals, and for the overdispersed species in particular, trends estimating using annual totals were more precise, and resulted in lower probabilities of estimating a trend (1 in the wrong direction, or (2 with credible intervals that excluded the true trend, as compared with hourly and daily counts.

  11. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  12. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  13. Categorical counting.

    Science.gov (United States)

    Fetterman, J Gregor; Killeen, P Richard

    2010-09-01

    Pigeons pecked on three keys, responses to one of which could be reinforced after a few pecks, to a second key after a somewhat larger number of pecks, and to a third key after the maximum pecking requirement. The values of the pecking requirements and the proportion of trials ending with reinforcement were varied. Transits among the keys were an orderly function of peck number, and showed approximately proportional changes with changes in the pecking requirements, consistent with Weber's law. Standard deviations of the switch points between successive keys increased more slowly within a condition than across conditions. Changes in reinforcement probability produced changes in the location of the psychometric functions that were consistent with models of timing. Analyses of the number of pecks emitted and the duration of the pecking sequences demonstrated that peck number was the primary determinant of choice, but that passage of time also played some role. We capture the basic results with a standard model of counting, which we qualify to account for the secondary experiments. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Quality control methods in accelerometer data processing: identifying extreme counts.

    Directory of Open Access Journals (Sweden)

    Carly Rich

    Full Text Available Accelerometers are designed to measure plausible human activity, however extremely high count values (EHCV have been recorded in large-scale studies. Using population data, we develop methodological principles for establishing an EHCV threshold, propose a threshold to define EHCV in the ActiGraph GT1M, determine occurrences of EHCV in a large-scale study, identify device-specific error values, and investigate the influence of varying EHCV thresholds on daily vigorous PA (VPA.We estimated quantiles to analyse the distribution of all accelerometer positive count values obtained from 9005 seven-year old children participating in the UK Millennium Cohort Study. A threshold to identify EHCV was derived by differentiating the quantile function. Data were screened for device-specific error count values and EHCV, and a sensitivity analysis conducted to compare daily VPA estimates using three approaches to accounting for EHCV.Using our proposed threshold of ≥ 11,715 counts/minute to identify EHCV, we found that only 0.7% of all non-zero counts measured in MCS children were EHCV; in 99.7% of these children, EHCV comprised < 1% of total non-zero counts. Only 11 MCS children (0.12% of sample returned accelerometers that contained negative counts; out of 237 such values, 211 counts were equal to -32,768 in one child. The medians of daily minutes spent in VPA obtained without excluding EHCV, and when using a higher threshold (≥19,442 counts/minute were, respectively, 6.2% and 4.6% higher than when using our threshold (6.5 minutes; p<0.0001.Quality control processes should be undertaken during accelerometer fieldwork and prior to analysing data to identify monitors recording error values and EHCV. The proposed threshold will improve the validity of VPA estimates in children's studies using the ActiGraph GT1M by ensuring only plausible data are analysed. These methods can be applied to define appropriate EHCV thresholds for different accelerometer models.

  15. Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers

    International Nuclear Information System (INIS)

    Van Laere, K.; Versijpt, J.; Dierckx, R.; Koole, M.

    2001-01-01

    Although non-uniform attenuation correction (NUAC) can supply more accurate absolute quantification, it is not entirely clear whether NUAC provides clear-cut benefits in the routine clinical practice of brain SPET imaging. The aim of this study was to compare the effect of NUAC versus uniform attenuation correction (UAC) on volume of interest (VOI)-based semi-quantification of a large age- and gender-stratified brain perfusion normal database. Eighty-nine healthy volunteers (46 females and 43 males, aged 20-81 years) underwent standardised high-resolution single-photon emission tomography (SPET) with 925 MBq 99m Tc-ethyl cysteinate dimer (ECD) on a Toshiba GCA-9300A camera with 153 Gd or 99m Tc transmission CT scanning. Emission images were reconstructed by filtered back-projection and scatter corrected using the triple-energy window correction method. Both non-uniform Chang attenuation correction (one iteration) and uniform Sorenson correction (attenuation coefficient 0.09 cm -1 ) were applied. Images were automatically re-oriented to a stereotactic template on which 35 predefined VOIs were defined for semi-quantification (normalisation on total VOI counts). Small but significant differences between relative VOI uptake values for NUAC versus UAC in the infratentorial region were found. VOI standard deviations were significantly smaller for UAC, 4.5% (range 2.6-7.5), than for NUAC, 5.0% (2.3-9.0) (P 99m Tc-ECD uptake values in healthy volunteers to those obtained with NUAC, although values for the infratentorial region are slightly lower. NUAC produces a slight increase in inter-subject variability. Further study is necessary in various patient populations to establish the full clinical impact of NUAC in brain perfusion SPET. (orig.)

  16. Testing the count rate performance of the scintillation camera by exponential attenuation: Decaying source; Multiple filters

    International Nuclear Information System (INIS)

    Adams, R.; Mena, I.

    1988-01-01

    An algorithm and two fortrAN programs have been developed to evaluate the count rate performance of scintillation cameras from count rates reduced exponentially, either by a decaying source or by filtration. The first method is used with short-lived radionuclides such as 191 /sup m/Ir or 191 /sup m/Au. The second implements a National Electrical Manufacturers' Association (NEMA) protocol in which the count rate from a source of 191 /sup m/Tc is attenuated by a varying number of copper filters stacked over it. The count rate at each data point is corrected for deadtime loss after assigning an arbitrary deadtime (tau). A second-order polynomial equation is fitted to the logarithms of net count rate values: ln(R) = A+BT+CT 2 where R is the net corrected count rate (cps), and T is the elapsed time (or the filter thickness in the NEMA method). Depending on C, tau is incremented or decremented iteratively, and the count rate corrections and curve fittings are repeated until C approaches zero, indicating a correct value of the deadtime (tau). The program then plots the measured count rate versus the corrected count rate values

  17. Negative binomial mixed models for analyzing microbiome count data.

    Science.gov (United States)

    Zhang, Xinyan; Mallick, Himel; Tang, Zaixiang; Zhang, Lei; Cui, Xiangqin; Benson, Andrew K; Yi, Nengjun

    2017-01-03

    Recent advances in next-generation sequencing (NGS) technology enable researchers to collect a large volume of metagenomic sequencing data. These data provide valuable resources for investigating interactions between the microbiome and host environmental/clinical factors. In addition to the well-known properties of microbiome count measurements, for example, varied total sequence reads across samples, over-dispersion and zero-inflation, microbiome studies usually collect samples with hierarchical structures, which introduce correlation among the samples and thus further complicate the analysis and interpretation of microbiome count data. In this article, we propose negative binomial mixed models (NBMMs) for detecting the association between the microbiome and host environmental/clinical factors for correlated microbiome count data. Although having not dealt with zero-inflation, the proposed mixed-effects models account for correlation among the samples by incorporating random effects into the commonly used fixed-effects negative binomial model, and can efficiently handle over-dispersion and varying total reads. We have developed a flexible and efficient IWLS (Iterative Weighted Least Squares) algorithm to fit the proposed NBMMs by taking advantage of the standard procedure for fitting the linear mixed models. We evaluate and demonstrate the proposed method via extensive simulation studies and the application to mouse gut microbiome data. The results show that the proposed method has desirable properties and outperform the previously used methods in terms of both empirical power and Type I error. The method has been incorporated into the freely available R package BhGLM ( http://www.ssg.uab.edu/bhglm/ and http://github.com/abbyyan3/BhGLM ), providing a useful tool for analyzing microbiome data.

  18. Effects of lek count protocols on greater sage-grouse population trend estimates

    Science.gov (United States)

    Monroe, Adrian; Edmunds, David; Aldridge, Cameron L.

    2016-01-01

    Annual counts of males displaying at lek sites are an important tool for monitoring greater sage-grouse populations (Centrocercus urophasianus), but seasonal and diurnal variation in lek attendance may increase variance and bias of trend analyses. Recommendations for protocols to reduce observation error have called for restricting lek counts to within 30 minutes of sunrise, but this may limit the number of lek counts available for analysis, particularly from years before monitoring was widely standardized. Reducing the temporal window for conducting lek counts also may constrain the ability of agencies to monitor leks efficiently. We used lek count data collected across Wyoming during 1995−2014 to investigate the effect of lek counts conducted between 30 minutes before and 30, 60, or 90 minutes after sunrise on population trend estimates. We also evaluated trends across scales relevant to management, including statewide, within Working Group Areas and Core Areas, and for individual leks. To further evaluate accuracy and precision of trend estimates from lek count protocols, we used simulations based on a lek attendance model and compared simulated and estimated values of annual rate of change in population size (λ) from scenarios of varying numbers of leks, lek count timing, and count frequency (counts/lek/year). We found that restricting analyses to counts conducted within 30 minutes of sunrise generally did not improve precision of population trend estimates, although differences among timings increased as the number of leks and count frequency decreased. Lek attendance declined >30 minutes after sunrise, but simulations indicated that including lek counts conducted up to 90 minutes after sunrise can increase the number of leks monitored compared to trend estimates based on counts conducted within 30 minutes of sunrise. This increase in leks monitored resulted in greater precision of estimates without reducing accuracy. Increasing count

  19. Design, fabrication and commissioning of motorized scanning bed mechanism for shadow shield whole body counting system

    International Nuclear Information System (INIS)

    Arun, B.; Varalakshimi, S.; Manohari, M.; Mathiyarasu, R.

    2012-01-01

    A new scanning bed mechanism for shadow shield counting system is designed, fabricated and commissioned at RSD, IGCAR. The present motorized scanning bed mechanism has varying scan speeds, state of art limit sensors, smooth bed movement, touch screen based software controlled operation parameters with UPS power back-up. In view of the improved personnel safety the entire system has been designed to operate with low voltage power supply (24V). The evaluation demonstrated that the incorporation of the new motorized scanning mechanism has not affected the counting performance of the shadow shield wholebody counting system. (author)

  20. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  1. Benjamin Thompson, Count Rumford Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    1967-01-01

    Men of Physics: Benjamin Thompson - Count Rumford: Count Rumford on the Nature of Heat covers the significant contributions of Count Rumford in the fields of physics. Count Rumford was born with the name Benjamin Thompson on March 23, 1753, in Woburn, Massachusetts. This book is composed of two parts encompassing 11 chapters, and begins with a presentation of Benjamin Thompson's biography and his interest in physics, particularly as an advocate of an """"anti-caloric"""" theory of heat. The subsequent chapters are devoted to his many discoveries that profoundly affected the physical thought

  2. Seasonality of helminth infection in wild red deer varies between individuals and between parasite taxa.

    Science.gov (United States)

    Albery, Gregory F; Kenyon, Fiona; Morris, Alison; Morris, Sean; Nussey, Daniel H; Pemberton, Josephine M

    2018-03-09

    Parasitism in wild mammals can vary according to myriad intrinsic and extrinsic factors, many of which vary seasonally. However, seasonal variation in parasitism is rarely studied using repeated samples from known individuals. Here we used a wild population of individually recognized red deer (Cervus elaphus) on the Isle of Rum to quantify seasonality and intrinsic factors affecting gastrointestinal helminth parasitism over the course of a year. We collected 1020 non-invasive faecal samples from 328 known individuals which we then analysed for propagules of three helminth taxa: strongyle nematodes, the common liver fluke Fasciola hepatica and the tissue nematode Elaphostrongylus cervi. Zero-inflated Poisson models were used to investigate how season, age and sex were associated with parasite prevalence and count intensity, while Poisson models were used to quantify individual repeatability within and between sampling seasons. Parasite intensity and prevalence varied according to all investigated factors, with opposing seasonality, age profiles and sex biases between parasite taxa. Repeatability was moderate, decreased between seasons and varied between parasites; both F. hepatica and E. cervi showed significant between-season repeatability, while strongyle nematode counts were only repeatable within-season and showed no repeatability within individuals across the year.

  3. Study on the behaviour of timing photomultipliers at a high counting rate

    International Nuclear Information System (INIS)

    Gladyshev, D.A.; Li, B.N.; Yunusov, Kh.R.

    1978-01-01

    Variations in the amplification factor K of a photomultiplier (PMU) with the accuracy of 1% in a pulse mode are studied. Measurements were performed by means of a light pulse generator based on a light diode which generates pulses at the repetition rate of 250-10 5 pulse/s. Relative variations in K were determined by the position of the peak gravity centre from the light diode using a pulse analyzer and a frequency meter. Results of PM testing show that, at a sudden counting rate increase, the amplification increases during the time period less than, the measurement time (less than 1 s) and returns to the stationary value. When the counting rate returns from 10 5 pulse/s to the initial value of 250 pulse/s, the amplification decreases and than increases to stationary value. The total time of K stabilization after counting rate applying constitutes 10-70 min. Restoration of K after counting rate removal occurs to be much slower, during 3 hr. 40 min. K values varied from 1 to 12%

  4. An intercomparison between gross α counting and gross β counting for grab-sampling determination of airborne radon progeny and thoron progeny

    International Nuclear Information System (INIS)

    Papp, Z.

    2006-01-01

    The instantaneous values of the airborne activity concentrations of radon progeny and thoron progeny have been determined 34 times in a closed and windowless room in a cellar using two independent grab-sampling methods in order to compare the performance of the methods. The activity concentration of radon ( 222 Rn) was also measured and it varied between 200 and 650 Bq m -3 . Two samples of radon and thoron progeny were collected simultaneously from roughly the same air volume by filtering. For the first method, the isotopes were collected on membrane filter and gross α counting was applied over several successive time intervals. This method was a slightly improved version of the methods that are applied generally for this reason for decades. For the second method, the isotopes were collected on glass-fibre filter and gross β counts were registered over several time intervals. This other method was developed a few years ago and the above series of measurements was the first opportunity to make an intercomparison between it and another similar method based on α counting. Individual radon progeny and thoron progeny activity concentrations (for the isotopes 218 Po, 214 Pb, 214 Bi and 212 Pb) were evaluated by both methods. The detailed investigation of the results showed that the systematic deviation of the methods is small but significant and isotope-dependent. The weighted averages of the β/α activity concentration ratios for 218 Po, 214 Pb, 214 Bi, EEDC 222 (Equilibrium-Equivalent Decay-product Concentration of radon progeny) and 212 Pb were 0.99±0.03, 0.90±0.02, 1.03±0.02, 0.96±0.02 and 0.80±0.03, respectively. The source of the systematic deviation is probably the inaccurate knowledge of the counting efficiencies mainly in the case of the α-counting method. A significant random-type difference between the results obtained with the two methods has also been revealed. For example, the β/α ratio for EEDC 222 varied between 0.81±0.01 and 1.22±0

  5. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  6. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Short communication: Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count.

    Science.gov (United States)

    Koop, G; Dik, N; Nielen, M; Lipman, L J A

    2010-06-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  9. Bayesian dynamic modeling of time series of dengue disease case counts.

    Science.gov (United States)

    Martínez-Bello, Daniel Adyro; López-Quílez, Antonio; Torres-Prieto, Alexander

    2017-07-01

    The aim of this study is to model the association between weekly time series of dengue case counts and meteorological variables, in a high-incidence city of Colombia, applying Bayesian hierarchical dynamic generalized linear models over the period January 2008 to August 2015. Additionally, we evaluate the model's short-term performance for predicting dengue cases. The methodology shows dynamic Poisson log link models including constant or time-varying coefficients for the meteorological variables. Calendar effects were modeled using constant or first- or second-order random walk time-varying coefficients. The meteorological variables were modeled using constant coefficients and first-order random walk time-varying coefficients. We applied Markov Chain Monte Carlo simulations for parameter estimation, and deviance information criterion statistic (DIC) for model selection. We assessed the short-term predictive performance of the selected final model, at several time points within the study period using the mean absolute percentage error. The results showed the best model including first-order random walk time-varying coefficients for calendar trend and first-order random walk time-varying coefficients for the meteorological variables. Besides the computational challenges, interpreting the results implies a complete analysis of the time series of dengue with respect to the parameter estimates of the meteorological effects. We found small values of the mean absolute percentage errors at one or two weeks out-of-sample predictions for most prediction points, associated with low volatility periods in the dengue counts. We discuss the advantages and limitations of the dynamic Poisson models for studying the association between time series of dengue disease and meteorological variables. The key conclusion of the study is that dynamic Poisson models account for the dynamic nature of the variables involved in the modeling of time series of dengue disease, producing useful

  10. Response of maize ( Zea mays L.) to varied moisture levels under ...

    African Journals Online (AJOL)

    Laboratory and glasshouse trials were used to determine the response of maize plants to varied moisture levels under Striga lutea infestation. Six moisture levels (1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 ml) were applied to striga seed for germination count in the laboratory, while five moisture levels (300, 600, 900, 1200 and 1500 ml) ...

  11. Equivariant volumes of non-compact quotients and instanton counting

    OpenAIRE

    Martens, Johan

    2006-01-01

    Motivated by Nekrasov's instanton counting, we discuss a method for calculating equivariant volumes of non-compact quotients in symplectic and hyper-K\\"ahler geometry by means of the Jeffrey-Kirwan residue-formula of non-abelian localization. In order to overcome the non-compactness, we use varying symplectic cuts to reduce the problem to a compact setting, and study what happens in the limit that recovers the original problem. We implement this method for the ADHM construction of the moduli ...

  12. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  13. Evaluating remotely sensed plant count accuracy with differing unmanned aircraft system altitudes, physical canopy separations, and ground covers

    Science.gov (United States)

    Leiva, Josue Nahun; Robbins, James; Saraswat, Dharmendra; She, Ying; Ehsani, Reza

    2017-07-01

    This study evaluated the effect of flight altitude and canopy separation of container-grown Fire Chief™ arborvitae (Thuja occidentalis L.) on counting accuracy. Images were taken at 6, 12, and 22 m above the ground using unmanned aircraft systems. Plants were spaced to achieve three canopy separation treatments: 5 cm between canopy edges, canopy edges touching, and 5 cm of canopy edge overlap. Plants were placed on two different ground covers: black fabric and gravel. A counting algorithm was trained using Feature Analyst®. Total counting error, false positives, and unidentified plants were reported for images analyzed. In general, total counting error was smaller when plants were fully separated. The effect of ground cover on counting accuracy varied with the counting algorithm. Total counting error for plants placed on gravel (-8) was larger than for those on a black fabric (-2), however, false positive counts were similar for black fabric (6) and gravel (6). Nevertheless, output images of plants placed on gravel did not show a negative effect due to the ground cover but was impacted by differences in image spatial resolution.

  14. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  15. Determination of radon in indoor air in Quebec by liquid scintillation counting in ortho-xylene

    Energy Technology Data Exchange (ETDEWEB)

    Chah, B; Zikovsky, L; Champagne, P [Ecole Polytechnique, Montreal, PQ (Canada)

    1992-01-01

    A new method for the determination of radon in air has been developed. it is based on low temperature absorption of radon in ortho-xylene followed by liquid scintillation counting. The method is reasonably fast and sensitive enough to analyse air without precipitation. The detection limit at the 95% confidence level for a 20 l air sample and 1 h counting time is 2 mBql{sup -1}. Radon concentrations measured in indoor air in Quebec varied from 7 to 162 mBql{sup -1}. (Author).

  16. Numerical counting ratemeter with variable time constant and integrated circuits

    International Nuclear Information System (INIS)

    Kaiser, J.; Fuan, J.

    1967-01-01

    We present here the prototype of a numerical counting ratemeter which is a special version of variable time-constant frequency meter (1). The originality of this work lies in the fact that the change in the time constant is carried out automatically. Since the criterion for this change is the accuracy in the annunciated result, the integration time is varied as a function of the frequency. For the prototype described in this report, the time constant varies from 1 sec to 1 millisec. for frequencies in the range 10 Hz to 10 MHz. This prototype is built entirely of MECL-type integrated circuits from Motorola and is thus contained in two relatively small boxes. (authors) [fr

  17. Influence of the type of milking and storage of milk on the chem ical composition, Somatic Cell Count and bacterial count Total

    Directory of Open Access Journals (Sweden)

    Aline Leite Peixoto

    2017-03-01

    Full Text Available The refrigeration of milk and the usage of mechanical milking are important to obtain milk in accordance with quality standards. In this work we evaluated the influence of the type of milking process and type of storage on the quality of the refrigerated milk. It was obtained 1363 refrigerated milk samples stored in single or collective expansion tanks, from manually or mechanically milked animals. The experiment was carried out in a 2x2 randomized factorial scheme. Two types of expansion tanks (single and collective and two types of milking (manual and mechanical. The average comparison test and Tukey test was carried out with 95% confidence. The levels of fat, protein, lactose and defatted dry extract, were evaluated according to the type of milking and type of milk storage. The values obtained were higher when compared to the values stabilished by the Ministry of Agriculture, Livestock and Food Supply. The level of milk fat was higher in samples with somatic cell count above 501,000 SC/mL. However, the levels of protein and defatted dry extract were higher in samples with somatic cell count below 500,000 SC/mL. The type of milking and the type of storage have influence on parameters related to milk quality such as levels of fat, protein, lactose and somatic cell count. The milk chemical composition revealed in accordance with the values stabilished by the Brazilian legislation. The total bacterial count did not vary with storage type nor the type of milking.

  18. Receiver operating characteristic (ROC) curve for classification of {sup 18}F-NaF uptake on PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Valadares, Agnes Araujo, E-mail: agnesvaladares@me.com [Universidade de Sao Paulo (HC/FM/USP), SP (Brazil). Hospital das Clinicas. Fac. de Mediciana; Duarte, Paulo Schiavom; Ono, Carla Rachel; Coura-Filho, George Barberio; Sado, Heitor Naoki; Carvalho, Giovanna [Instituto do Cancer do Estado de Sao Paulo Octavio Frias de Oliveira (ICESP), Sao Paulo, SP (Brazil). Servico de Medicina Nuclear; Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Dept. de Radiologia e Oncologia

    2016-01-15

    Objective: To assess the cutoff values established by ROC curves to classify {sup 18}F-NaF uptake as normal or malignant. Materials and Methods: PET/CT images were acquired 1 hour after administration of 185 MBq of {sup 18}F-NaF. Volumes of interest (VOIs) were drawn on three regions of the skeleton as follows: proximal right humerus diaphysis (HD), proximal right femoral diaphysis (FD) and first vertebral body (VB1), in a total of 254 patients, totalling 762 VOIs. The uptake in the VOIs was classified as normal or malignant on the basis of the radiopharmaceutical distribution pattern and of the CT images. A total of 675 volumes were classified as normal and 52 were classified as malignant. Thirty-five VOIs classified as indeterminate or nonmalignant lesions were excluded from analysis. The standardized uptake value (SUV) measured on the VOIs were plotted on an ROC curve for each one of the three regions. The area under the ROC (AUC) as well as the best cutoff SUVs to classify the VOIs were calculated. The best cutoff values were established as the ones with higher result of the sum of sensitivity and specificity. Results: The AUCs were 0.933, 0.889 and 0.975 for UD, FD and VB1, respectively. The best SUV cutoffs were 9.0 (sensitivity: 73%; specificity: 99%), 8.4 (sensitivity: 79%; specificity: 94%) and 21.0 (sensitivity: 93%; specificity: 95%) for UD, FD and VB1, respectively. Conclusion: The best cutoff value varies according to bone region of analysis and it is not possible to establish one value for the whole body. (author)

  19. Modeling Systematic Change in Stopover Duration Does Not Improve Bias in Trends Estimated from Migration Counts.

    Directory of Open Access Journals (Sweden)

    Tara L Crewe

    Full Text Available The use of counts of unmarked migrating animals to monitor long term population trends assumes independence of daily counts and a constant rate of detection. However, migratory stopovers often last days or weeks, violating the assumption of count independence. Further, a systematic change in stopover duration will result in a change in the probability of detecting individuals once, but also in the probability of detecting individuals on more than one sampling occasion. We tested how variation in stopover duration influenced accuracy and precision of population trends by simulating migration count data with known constant rate of population change and by allowing daily probability of survival (an index of stopover duration to remain constant, or to vary randomly, cyclically, or increase linearly over time by various levels. Using simulated datasets with a systematic increase in stopover duration, we also tested whether any resulting bias in population trend could be reduced by modeling the underlying source of variation in detection, or by subsampling data to every three or five days to reduce the incidence of recounting. Mean bias in population trend did not differ significantly from zero when stopover duration remained constant or varied randomly over time, but bias and the detection of false trends increased significantly with a systematic increase in stopover duration. Importantly, an increase in stopover duration over time resulted in a compounding effect on counts due to the increased probability of detection and of recounting on subsequent sampling occasions. Under this scenario, bias in population trend could not be modeled using a covariate for stopover duration alone. Rather, to improve inference drawn about long term population change using counts of unmarked migrants, analyses must include a covariate for stopover duration, as well as incorporate sampling modifications (e.g., subsampling to reduce the probability that individuals will

  20. The Serial Change of Cerebral Hemodynamics by Vascular Territory after Extracranial-Intracranial Bypass Surgery in Patients with Atherosclerosis of Cerebral Arteries

    International Nuclear Information System (INIS)

    Hong, Il Ki; Kim, Jae Seung; Ahn, Jae Sung; Kwon, Sun Uck; Im, Ki Chun; Lee, Jai Hyuen; Moon, Dae Hyuk

    2008-01-01

    To assess the effect of extracranial-intracranial (EC-IC) bypass surgery on hemodynamic improvement, we evaluated serial regional cerebral hemodynamic change of the middle cerebral artery (MCA) in symptomatic patients with atherosclerotic occlusion of the internal carotid artery (ICA) or MCA using 99m Tc-ECD acetazolamide stress brain perfusion SPECT (Acetazolamide SPECT). The patients who had suffered a recent stroke with atherosclerotic ICA or MCA occlusion underwent EC-IC bypass surgery and Acetazolamide SPECT at 1 week before and three to six months after surgery. For image analysis, attenuation corrected images were spatially normalized to SPECT templates with SPM2. Anatomical automated labeling was applied to calculate mean counts of each Volume-Of-Interest (VOI). Seven VOIs of bilateral frontal, parietal, temporal regions of the MCA territory and the ipsilateral cerebellum were defined. Using mean counts of 7 VOIs, cerebral perfusion index and perfusion reserve index were calculated. Seventeen patients (M:F=12:5, mean age: 53±2yr) were finally included in the analysis. The cerebral blood flow of the parietal region increased at 1 week (p=0.003) and decreased to the preoperative level at 3-6 months (p=0.003). The cerebrovascular reserve of the frontal and parietal regions increased significantly at 1 week after surgery (p<0.01) and improved further at 3-6 months. Cerebrovascular reserve of the MCA territory was significantly improved at early postoperative period after EC-IC bypass and kept improved state during long-term follow-up, although cerebral blood flow did not significantly improved. Therefore, cerebrovascular reserve may be a good indicator of postoperative hemodynamic improvement resulted from bypass effect

  1. The Serial Change of Cerebral Hemodynamics by Vascular Territory after Extracranial-Intracranial Bypass Surgery in Patients with Atherosclerosis of Cerebral Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Il Ki; Kim, Jae Seung; Ahn, Jae Sung; Kwon, Sun Uck; Im, Ki Chun; Lee, Jai Hyuen; Moon, Dae Hyuk [Asan Medial Center, Ulsan University School of Medicine, Seoul (Korea, Republic of)

    2008-02-15

    To assess the effect of extracranial-intracranial (EC-IC) bypass surgery on hemodynamic improvement, we evaluated serial regional cerebral hemodynamic change of the middle cerebral artery (MCA) in symptomatic patients with atherosclerotic occlusion of the internal carotid artery (ICA) or MCA using {sup 99m}Tc-ECD acetazolamide stress brain perfusion SPECT (Acetazolamide SPECT). The patients who had suffered a recent stroke with atherosclerotic ICA or MCA occlusion underwent EC-IC bypass surgery and Acetazolamide SPECT at 1 week before and three to six months after surgery. For image analysis, attenuation corrected images were spatially normalized to SPECT templates with SPM2. Anatomical automated labeling was applied to calculate mean counts of each Volume-Of-Interest (VOI). Seven VOIs of bilateral frontal, parietal, temporal regions of the MCA territory and the ipsilateral cerebellum were defined. Using mean counts of 7 VOIs, cerebral perfusion index and perfusion reserve index were calculated. Seventeen patients (M:F=12:5, mean age: 53{+-}2yr) were finally included in the analysis. The cerebral blood flow of the parietal region increased at 1 week (p=0.003) and decreased to the preoperative level at 3-6 months (p=0.003). The cerebrovascular reserve of the frontal and parietal regions increased significantly at 1 week after surgery (p<0.01) and improved further at 3-6 months. Cerebrovascular reserve of the MCA territory was significantly improved at early postoperative period after EC-IC bypass and kept improved state during long-term follow-up, although cerebral blood flow did not significantly improved. Therefore, cerebrovascular reserve may be a good indicator of postoperative hemodynamic improvement resulted from bypass effect.

  2. Optimizing the calculation of point source count-centroid in pixel size measurement

    International Nuclear Information System (INIS)

    Zhou Luyi; Kuang Anren; Su Xianyu

    2004-01-01

    Purpose: Pixel size is an important parameter of gamma camera and SPECT. A number of Methods are used for its accurate measurement. In the original count-centroid method, where the image of a point source(PS) is acquired and its count-centroid calculated to represent PS position in the image, background counts are inevitable. Thus the measured count-centroid (Xm) is an approximation of the true count-centroid (Xp) of the PS, i.e. Xm=Xp+(Xb-Xp)/(1+Rp/Rb), where Rp is the net counting rate of the PS, Xb the background count-centroid and Rb the background counting rate. To get accurate measurement, Rp must be very big, which is unpractical, resulting in the variation of measured pixel size. Rp-independent calculation of PS count-centroid is desired. Methods: The proposed method attempted to eliminate the effect of the term (Xb-Xp)/(1+Rp/Rb) by bringing Xb closer to Xp and by reducing Rb. In the acquired PS image, a circular ROI was generated to enclose the PS, the pixel with the maximum count being the center of the ROI. To choose the diameter (D) of the ROI, a Gaussian count distribution was assumed for the PS, accordingly, K=I-(0.5)D/R percent of the total PS counts was in the ROI, R being the full width at half maximum of the PS count distribution. D was set to be 6*R to enclose most (K=98.4%) of the PS counts. The count-centroid of the ROI was calculated to represent Xp. The proposed method was tested in measuring the pixel size of a well-tuned SPECT, whose pixel size was estimated to be 3.02 mm according to its mechanical and electronic setting (128*128 matrix, 387 mm UFOV, ZOOM=1). For comparison, the original method, which was use in the former versions of some commercial SPECT software, was also tested. 12 PSs were prepared and their image acquired and stored. The net counting rate of the PSs increased from 10cps to 1183cps. Results: Using the proposed method, the measured pixel size (in mm) varied only between 3.00 and 3.01( mean= 3.01±0.00) as Rp increased

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  4. Do Mendeley reader counts reflect the scholarly impact of conference papers? An investigation of Computer Science and Engineering fields

    Energy Technology Data Exchange (ETDEWEB)

    Aduku, K.J.; Thelwall, M.; Kousha, K.

    2016-07-01

    Counts of Mendeley readers may give useful evidence about the impact of research. Although several studies have indicated that there are significant positive correlations between counts of Mendeley readers and citation counts for journal articles, it is not known how the pattern of association may vary between journal articles and conference papers. To fill this gap, Mendeley readership data and Scopus citation counts were extracted for both journal articles and conference papers published in 2011 in four fields for which conferences are important; Computer Science Applications, Computer Software, Building & Construction Engineering and Industrial & Manufacturing Engineering. Mendeley readership counts were found to correlate moderately with citation counts for both journal articles and conference papers in Computer Science Applications and Computer Software. Nevertheless, the correlations were much lower between Mendeley readers and citation counts for conference papers than for journal articles in Building & Construction Engineering and Industrial & Manufacturing Engineering. Hence, there seems to be disciplinary differences in the usefulness of Mendeley readership counts as impact indicators for conference papers, even between fields for which conferences are important. (Author)

  5. Noun Countability; Count Nouns and Non-count Nouns, What are the Syntactic Differences Between them?

    Directory of Open Access Journals (Sweden)

    Azhar A. Alkazwini

    2016-11-01

    Full Text Available Words that function as the subjects of verbs, objects of verbs or prepositions and which can have a plural form and possessive ending are known as nouns. They are described as referring to persons, places, things, states, or qualities and might also be used as an attributive modifier. In this paper, classes and subclasses of nouns shall be presented, then, noun countability branching into count and non-count nous shall be discussed. A number of present examples illustrating differences between count and non-count nouns and this includes determiner-head-co-occurrence restrictions of number, subject-verb agreement, in addition to some exceptions to this agreement rule shall be discussed. Also, the lexically inherent number in nouns and how inherently plural nouns are classified in terms of (+/- count are illustrated. This research will discuss partitive construction of count and non-count nouns, nouns as attributive modifier and, finally, conclude with the fact that there are syntactic difference between count and non-count in the English Language.

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  7. Count-to-count time interval distribution analysis in a fast reactor

    International Nuclear Information System (INIS)

    Perez-Navarro Gomez, A.

    1973-01-01

    The most important kinetic parameters have been measured at the zero power fast reactor CORAL-I by means of the reactor noise analysis in the time domain, using measurements of the count-to-count time intervals. (Author) 69 refs

  8. Microparticle counts in platelet-rich and platelet-free plasma, effect of centrifugation and sample-processing protocols.

    Science.gov (United States)

    Chandler, Wayne L

    2013-03-01

    This study provides the first estimates of microparticle numbers in platelet-rich plasma (PRP) from normal individuals, closer to in-vivo levels, using higher-resolution flow cytometry. We measured platelet (CD41+) and annexin V+ microparticles in fresh and frozen aliquots of PRP, platelet-poor plasma, platelet-free plasma (PFP), and microparticles isolated by high-speed centrifugation. PRP from healthy individuals contained 730,000/μl total microparticles based on light-scattering measurements. A median of 27,000/μl microparticles in PRP were of platelet origin and 120,000/μl annexin V+, and of these, 24,000/μl were dual-positive procoagulant platelet microparticles. Double centrifugation of PRP removed 99% of platelets, but also 80% of annexin V+ CD41+, 93% of annexin V+ CD41-, and 58% of annexin V- CD41+ microparticles. Loss of microparticles with centrifugation varied from individual to individual. Microparticle counts after isolation by centrifugation and double washing were not significantly different than counts in the original PFP sample, but lower than in PRP. Freeze-thawing of PFP had no effect on platelet microparticle counts, but slightly increased annexin V+, CD41- counts. Freeze-thawing of isolated washed microparticles resulted in a 30-50% increase in annexin V+ microparticles. PRP contains large numbers of cellular microparticles, including platelet and annexin V+ microparticles, which are lost to varying degrees when PRP is double centrifuged to remove platelets. Microparticles remaining in PFP can be recovered by high-speed centrifugation without loss compared to the original PFP sample. Freeze-thawing has variable effects on microparticle counts depending on the sample preparation used.

  9. Optimizing the calculation of point source count-centroid in pixel size measurement

    International Nuclear Information System (INIS)

    Zhou Luyi; Kuang Anren; Su Xianyu

    2004-01-01

    Pixel size is an important parameter of gamma camera and SPECT. A number of methods are used for its accurate measurement. In the original count-centroid method, where the image of a point source (PS) is acquired and its count-centroid calculated to represent PS position in the image, background counts are inevitable. Thus the measured count-centroid (X m ) is an approximation of the true count-centroid (X p ) of the PS, i.e. X m =X p + (X b -X p )/(1+R p /R b ), where Rp is the net counting rate of the PS, X b the background count-centroid and Rb the background counting. To get accurate measurement, R p must be very big, which is unpractical, resulting in the variation of measured pixel size. R p -independent calculation of PS count-centroid is desired. Methods: The proposed method attempted to eliminate the effect of the term (X b -X p )/(1 + R p /R b ) by bringing X b closer to X p and by reducing R b . In the acquired PS image, a circular ROI was generated to enclose the PS, the pixel with the maximum count being the center of the ROI. To choose the diameter (D) of the ROI, a Gaussian count distribution was assumed for the PS, accordingly, K=1-(0.5) D/R percent of the total PS counts was in the ROI, R being the full width at half maximum of the PS count distribution. D was set to be 6*R to enclose most (K=98.4%) of the PS counts. The count-centroid of the ROI was calculated to represent X p . The proposed method was tested in measuring the pixel size of a well-tuned SPECT, whose pixel size was estimated to be 3.02 mm according to its mechanical and electronic setting (128 x 128 matrix, 387 mm UFOV, ZOOM=1). For comparison, the original method, which was use in the former versions of some commercial SPECT software, was also tested. 12 PSs were prepared and their image acquired and stored. The net counting rate of the PSs increased from 10 cps to 1183 cps. Results: Using the proposed method, the measured pixel size (in mm) varied only between 3.00 and 3.01 (mean

  10. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  11. TasselNet: counting maize tassels in the wild via local counts regression network.

    Science.gov (United States)

    Lu, Hao; Cao, Zhiguo; Xiao, Yang; Zhuang, Bohan; Shen, Chunhua

    2017-01-01

    Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting ( MTC ) dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large margins and achieves the overall best counting

  12. TasselNet: counting maize tassels in the wild via local counts regression network

    Directory of Open Access Journals (Sweden)

    Hao Lu

    2017-11-01

    Full Text Available Abstract Background Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. Results This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting (MTC dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large

  13. Summative Self-Assessment in Higher Education: Implications of Its Counting towards the Final Mark

    Science.gov (United States)

    Tejeiro, Ricardo A.; Gomez-Vallecillo, Jorge L.; Romero, Antonio F.; Pelegrina, Manuel; Wallace, Agustin; Emberley, Enrique

    2012-01-01

    Introduction: Our study aims at assessing the validity of summative criteria-referenced self-assessment in higher education, and in particular, if that validity varies when the professor counts self-assessment toward the final mark. Method: One hundred and twenty-two first year students from two groups in Teacher Education at the Universidad de…

  14. Isospectral discrete and quantum graphs with the same flip counts and nodal counts

    Science.gov (United States)

    Juul, Jonas S.; Joyner, Christopher H.

    2018-06-01

    The existence of non-isomorphic graphs which share the same Laplace spectrum (to be referred to as isospectral graphs) leads naturally to the following question: what additional information is required in order to resolve isospectral graphs? It was suggested by Band, Shapira and Smilansky that this might be achieved by either counting the number of nodal domains or the number of times the eigenfunctions change sign (the so-called flip count) (Band et al 2006 J. Phys. A: Math. Gen. 39 13999–4014 Band and Smilansky 2007 Eur. Phys. J. Spec. Top. 145 171–9). Recent examples of (discrete) isospectral graphs with the same flip count and nodal count have been constructed by Ammann by utilising Godsil–McKay switching (Ammann private communication). Here, we provide a simple alternative mechanism that produces systematic examples of both discrete and quantum isospectral graphs with the same flip and nodal counts.

  15. Examining secular trend  and seasonality in count data using dynamic generalized linear modelling

    DEFF Research Database (Denmark)

    Lundbye-Christensen, Søren; Dethlefsen, Claus; Gorst-Rasmussen, Anders

    series regression model for Poisson counts. It differs in allowing the regression coefficients to vary gradually over time in a random fashion. Data  In the period January 1980 to 1999, 17,989 incidents of acute myocardial infarction were recorded in the county of Northern Jutland, Denmark. Records were......Aims  Time series of incidence counts often show secular trends and seasonal patterns. We present a model for incidence counts capable of handling a possible gradual change in growth rates and seasonal patterns, serial correlation and overdispersion. Methods  The model resembles an ordinary time...... updated daily. Results  The model with a seasonal pattern and an approximately linear trend was fitted to the data, and diagnostic plots indicate a good model fit. The analysis with the dynamic model revealed peaks coinciding with influenza epidemics. On average the peak-to-trough ratio is estimated...

  16. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  17. Recommendations for monitoring avian populations with point counts: a case study in southeastern Brazil

    Directory of Open Access Journals (Sweden)

    Vagner Cavarzere

    2013-01-01

    Full Text Available In the northern hemisphere, bird counts have been fundamental in gathering data to understand population trends. Due to the seasonality of the northern hemisphere, counts take place during two clearly defined moments in time: the breeding season (resident birds and winter (after migration. Depending on location, Neotropical birds may breed at any time of year, may or may not migrate, and those patterns are not necessarily synchronous among species. Also in contrast to the northern hemisphere, population trends and the impact of rapid urbanization and deforestation are unknown and unmonitored. Throughout one year, we used point counts to better understand temporal patterns of bird species richness and relative abundance in the state of São Paulo, southeastern Brazil, to examine how to implement similar bird counts in tropical America. We counted birds twice each day on 10 point transects (20 points day‑1, separated by 200 m, with a 100 m limited detection radius in a semideciduous tropical forest. Both species richness and bird abundance were greater in the morning, but accumulation curves suggest that longer-duration afternoon counts would reach the same total species as in morning counts. Species richness and bird abundance did not vary seasonally and unique species were counted every month; relatively few species (20% were present in all months. Most (84% known forest species in the area were encountered. We suggest that point counts can work here as they do in the northern hemisphere. We recommend that transects include at least 20 points and that the simplest timing of bird counts would also be seasonal, using timing of migration of austral migrants (and six months later to coordinate counts. We propose that bird counts in Brazil, and elsewhere in Latin America, would provide data to help understand population trends, but would require greater effort than in temperate latitudes due to greater species richness and different dynamics of

  18. Monte Carlo simulation of lung counting efficiency using a whole-body counter at a nuclear power plant

    International Nuclear Information System (INIS)

    Dongming, L.; Shuhai, J.; Houwen, L.

    2016-01-01

    In order to routinely evaluate workers' internal exposure due to intake of radionuclides, a whole-body counter (WBC) at the Third Qinshan Nuclear Power Co. Ltd. (TQNPC) is used. Counting would typically occur immediately after a confirmed or suspected inhalation exposure. The counting geometry would differ as a result of the height of the individual being counted, which would result in over- or underestimated intake(s). In this study, Monte Carlo simulation was applied to evaluate the counting efficiency when performing a lung count using the WBC at the TQNPC. In order to validate the simulated efficiencies for lung counting, the WBC was benchmarked for various lung positions using a 137 Cs source. The results show that the simulated efficiencies are fairly consistent with the measured ones for 137 Cs, with a relative error of 0.289%. For a lung organ simulation, the discrepancy between the calibration phantom and the Chinese reference adult person (170 cm) was within 6% for peak energies ranging from 59.5 keV to 2000 keV. The relative errors vary from 4.63% to 8.41% depending on the person's height and photon energy. Therefore, the simulation technique is effective and practical for lung counting, which is difficult to calibrate using a physical phantom. (authors)

  19. A Lossy Counting-Based State of Charge Estimation Method and Its Application to Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Hong Zhang

    2015-12-01

    Full Text Available Estimating the residual capacity or state-of-charge (SoC of commercial batteries on-line without destroying them or interrupting the power supply, is quite a challenging task for electric vehicle (EV designers. Many Coulomb counting-based methods have been used to calculate the remaining capacity in EV batteries or other portable devices. The main disadvantages of these methods are the cumulative error and the time-varying Coulombic efficiency, which are greatly influenced by the operating state (SoC, temperature and current. To deal with this problem, we propose a lossy counting-based Coulomb counting method for estimating the available capacity or SoC. The initial capacity of the tested battery is obtained from the open circuit voltage (OCV. The charging/discharging efficiencies, used for compensating the Coulombic losses, are calculated by the lossy counting-based method. The measurement drift, resulting from the current sensor, is amended with the distorted Coulombic efficiency matrix. Simulations and experimental results show that the proposed method is both effective and convenient.

  20. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  1. Pulse pile-up in nuclear particle detection systems with rapidly varying counting rates

    International Nuclear Information System (INIS)

    Datlowe, D.W.

    1977-01-01

    Pulse pile-up in nuclear particle detection systems is the distortion of the measured pulse height distribution which occurs when there is a significant probability that more than one particle will arrive within the detector resolving time. This paper treats the problem in cases where the probability of pile-up varies on a time scale comparable to the rise time of the detector system electronics. These variations introduce structure into the pulse height distributions which cannot occur for a time-independent pile-up probability. Three classes of problems which exemplify these effects are as follows: 1) Pile-up rejection circuits. 2) Cascaded nuclear decays, in which the lifetime for emission of a second X-ray is comparable to the detector rise time. 3) Bursts of particles where the intensity is modulated on a time scale comparable to the detector rise time. These problems are solved computationally by an extension of a numerical technique previously developed. (Auth.)

  2. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  3. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  4. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  5. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  6. Homicides by Police: Comparing Counts From the National Violent Death Reporting System, Vital Statistics, and Supplementary Homicide Reports.

    Science.gov (United States)

    Barber, Catherine; Azrael, Deborah; Cohen, Amy; Miller, Matthew; Thymes, Deonza; Wang, David Enze; Hemenway, David

    2016-05-01

    To evaluate the National Violent Death Reporting System (NVDRS) as a surveillance system for homicides by law enforcement officers. We assessed sensitivity and positive predictive value of the NVDRS "type of death" variable against our study count of homicides by police, which we derived from NVDRS coded and narrative data for states participating in NVDRS 2005 to 2012. We compared state counts of police homicides from NVDRS, Vital Statistics, and Federal Bureau of Investigation Supplementary Homicide Reports. We identified 1552 police homicides in the 16 states. Positive predictive value and sensitivity of the NVDRS "type of death" variable for police homicides were high (98% and 90%, respectively). Counts from Vital Statistics and Supplementary Homicide Reports were 58% and 48%, respectively, of our study total; gaps varied widely by state. The annual rate of police homicide (0.24/100,000) varied 5-fold by state and 8-fold by race/ethnicity. NVDRS provides more complete data on police homicides than do existing systems. Expanding NVDRS to all 50 states and making 2 improvements we identify will be an efficient way to provide the nation with more accurate, detailed data on homicides by law enforcement.

  7. Methematical model of a neutron counting system used for the characteristics control of spontaneously fissioning material

    International Nuclear Information System (INIS)

    Bessis, J.

    1986-09-01

    Methods are described for calculating the probabilities, p(m), of detection of m neutrons, inside a split millisecond counting gate, m varying from zero to some units. At the present stage, these methods suppose the source to be very small. Using the generating function concept, they concern both possible modes of the counting system, for opening gates, i.e.: 1) Trigger pulses randomly with regard to the emitted neutrons, 2) Trigger pulses from the detected neutrons themselves. Computed values are finally compared to the measured ones. This comparison seems to be very favourable, since the respective deviations are often lower than 1 % [fr

  8. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  9. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  10. Correlation between total lymphocyte count, hemoglobin, hematocrit and CD4 count in HIV patients in Nigeria.

    Science.gov (United States)

    Emuchay, Charles Iheanyichi; Okeniyi, Shemaiah Olufemi; Okeniyi, Joshua Olusegun

    2014-04-01

    The expensive and technology limited setting of CD4 count testing is a major setback to the initiation of HAART in a resource limited country like Nigeria. Simple and inexpensive tools such as Hemoglobin (Hb) measurement and Total Lymphocyte Count (TLC) are recommended as substitute marker. In order to assess the correlations of these parameters with CD4 count, 100 "apparently healthy" male volunteers tested HIV positive aged ≥ 20 years but ≤ 40 years were recruited and from whom Hb, Hct, TLC and CD4 count were obtained. The correlation coefficients, R, the Nash-Sutcliffe Coefficient of Efficiency (CoE) and the p-values of the ANOVA model of Hb, Hct and TLC with CD4 count were assessed. The assessments show that there is no significant relationship of any of these parameters with CD4 count and the correlation coefficients are very weak. This study shows that Hb, Hct and TLC cannot be substitute for CD4 count as this might lead to certain individuals' deprivation of required treatment.

  11. It counts who counts: an experimental evaluation of the importance of observer effects on spotlight count estimates

    DEFF Research Database (Denmark)

    Sunde, Peter; Jessen, Lonnie

    2013-01-01

    observers with respect to their ability to detect and estimate distance to realistic animal silhouettes at different distances. Detection probabilities were higher for observers experienced in spotlighting mammals than for inexperienced observers, higher for observers with a hunting background compared...... with non-hunters and decreased as function of age but were independent of sex or educational background. If observer-specific detection probabilities were applied to real counting routes, point count estimates from inexperienced observers without a hunting background would only be 43 % (95 % CI, 39...

  12. You can count on the motor cortex: Finger counting habits modulate motor cortex activation evoked by numbers

    Science.gov (United States)

    Tschentscher, Nadja; Hauk, Olaf; Fischer, Martin H.; Pulvermüller, Friedemann

    2012-01-01

    The embodied cognition framework suggests that neural systems for perception and action are engaged during higher cognitive processes. In an event-related fMRI study, we tested this claim for the abstract domain of numerical symbol processing: is the human cortical motor system part of the representation of numbers, and is organization of numerical knowledge influenced by individual finger counting habits? Developmental studies suggest a link between numerals and finger counting habits due to the acquisition of numerical skills through finger counting in childhood. In the present study, digits 1 to 9 and the corresponding number words were presented visually to adults with different finger counting habits, i.e. left- and right-starters who reported that they usually start counting small numbers with their left and right hand, respectively. Despite the absence of overt hand movements, the hemisphere contralateral to the hand used for counting small numbers was activated when small numbers were presented. The correspondence between finger counting habits and hemispheric motor activation is consistent with an intrinsic functional link between finger counting and number processing. PMID:22133748

  13. Total lymphocyte count and subpopulation lymphocyte counts in relation to dietary intake and nutritional status of peritoneal dialysis patients.

    Science.gov (United States)

    Grzegorzewska, Alicja E; Leander, Magdalena

    2005-01-01

    Dietary deficiency causes abnormalities in circulating lymphocyte counts. For the present paper, we evaluated correlations between total and subpopulation lymphocyte counts (TLC, SLCs) and parameters of nutrition in peritoneal dialysis (PD) patients. Studies were carried out in 55 patients treated with PD for 22.2 +/- 11.4 months. Parameters of nutritional status included total body mass, lean body mass (LBM), body mass index (BMI), and laboratory indices [total protein, albumin, iron, ferritin, and total iron binding capacity (TIBC)]. The SLCs were evaluated using flow cytometry. Positive correlations were seen between TLC and dietary intake of niacin; TLC and CD8 and CD16+56 counts and energy delivered from protein; CD4 count and beta-carotene and monounsaturated fatty acids 17:1 intake; and CD19 count and potassium, copper, vitamin A, and beta-carotene intake. Anorexia negatively influenced CD19 count. Serum albumin showed correlations with CD4 and CD19 counts, and LBM with CD19 count. A higher CD19 count was connected with a higher red blood cell count, hemoglobin, and hematocrit. Correlations were observed between TIBC and TLC and CD3 and CD8 counts, and between serum Fe and TLC and CD3 and CD4 counts. Patients with a higher CD19 count showed a better clinical-laboratory score, especially less weakness. Patients with a higher CD4 count had less expressed insomnia. Quantities of ingested vitamins and minerals influence lymphocyte counts in the peripheral blood of PD patients. Evaluation of TLC and SLCs is helpful in monitoring the effectiveness of nutrition in these patients.

  14. The characteristics of cortical glucose metabolism in amblyopia

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Ji Young [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of); Lee, Dong Soo; Chung, June Key; Shin, Seung Ai; Lee, Myung Chul [College of Medicine, Ewha Womans Univ., Seoul (Korea, Republic of)

    2000-07-01

    Cortical metabolism of amblyopia patients was investigated with F-18-FDG PET and Statistical Parametric Mapping (SPM) and quantificiation based on volume of interest (VOI) by statistical probabilistic anatomical map (SPAM). In 9 amblyopic patients (12{+-}7 years ) and 20 normal subjects (23{+-}2 years), F-18-FDG PET scans were peformed in amblyopic patients after amblyopic eye or sound eye was patch-closed during PET studies. SPM was done with SPM96. By multiplying SPAM to FDG images, counts of 98 VOI's were calculated and compared with 3 S. D. range of those of normal subjects. On SPM, cortical metabolism decreased (p<0.05) in occipital lobe (Ba 17, 18, 19), superior partietal lobe (Ba 7), and inferior temporal lobe (BA 37, 20). FDG uptake of gyri of occuipital lobe was decreased in 2 and increased in 2, and was normal in the other 5. FDG uptake of gyri of parietal, frontal, and temporal lobes were decreased in FDG uptake on these VOIs. We conclude that cortical metabolism in occipital lobe and extraoccipital lobes was variable but was consistent regardless of visual input during PET studies in amblyopic patients. SPM and quantification of functional images using SPAM could reveal subtle differences or changes according to visual input. The significance of metabolic changes of extraoccipital lobes should be studies further.

  15. The characteristics of cortical glucose metabolism in amblyopia

    International Nuclear Information System (INIS)

    Ahn, Ji Young; Lee, Dong Soo; Chung, June Key; Shin, Seung Ai; Lee, Myung Chul

    2000-01-01

    Cortical metabolism of amblyopia patients was investigated with F-18-FDG PET and Statistical Parametric Mapping (SPM) and quantificiation based on volume of interest (VOI) by statistical probabilistic anatomical map (SPAM). In 9 amblyopic patients (12±7 years ) and 20 normal subjects (23±2 years), F-18-FDG PET scans were peformed in amblyopic patients after amblyopic eye or sound eye was patch-closed during PET studies. SPM was done with SPM96. By multiplying SPAM to FDG images, counts of 98 VOI's were calculated and compared with 3 S. D. range of those of normal subjects. On SPM, cortical metabolism decreased (p<0.05) in occipital lobe (Ba 17, 18, 19), superior partietal lobe (Ba 7), and inferior temporal lobe (BA 37, 20). FDG uptake of gyri of occuipital lobe was decreased in 2 and increased in 2, and was normal in the other 5. FDG uptake of gyri of parietal, frontal, and temporal lobes were decreased in FDG uptake on these VOIs. We conclude that cortical metabolism in occipital lobe and extraoccipital lobes was variable but was consistent regardless of visual input during PET studies in amblyopic patients. SPM and quantification of functional images using SPAM could reveal subtle differences or changes according to visual input. The significance of metabolic changes of extraoccipital lobes should be studies further

  16. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  17. First principle active neutron coincidence counting measurements of uranium oxide

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, Braden, E-mail: goddard.braden@gmail.com [Nuclear Security Science and Policy Institute, Texas A and M University, College Station, Texas 77843 (United States); Charlton, William [Nuclear Security Science and Policy Institute, Texas A and M University, College Station, Texas 77843 (United States); Peerani, Paolo [European Commission, EC-JRC-ITU, Ispra (Italy)

    2014-03-01

    Uranium is present in most nuclear fuel cycle facilities ranging from uranium mines, enrichment plants, fuel fabrication facilities, nuclear reactors, and reprocessing plants. The isotopic, chemical, and geometric composition of uranium can vary significantly between these facilities, depending on the application and type of facility. Examples of this variation are: enrichments varying from depleted (∼0.2 wt% {sup 235}U) to high enriched (>20 wt% {sup 235}U); compositions consisting of U{sub 3}O{sub 8}, UO{sub 2}, UF{sub 6}, metallic, and ceramic forms; geometries ranging from plates, cans, and rods; and masses which can range from a 500 kg fuel assembly down to a few grams fuel pellet. Since {sup 235}U is a fissile material, it is routinely safeguarded in these facilities. Current techniques for quantifying the {sup 235}U mass in a sample include neutron coincidence counting. One of the main disadvantages of this technique is that it requires a known standard of representative geometry and composition for calibration, which opens up a pathway for potential erroneous declarations by the State and reduces the effectiveness of safeguards. In order to address this weakness, the authors have developed a neutron coincidence counting technique which uses the first principle point-model developed by Boehnel instead of the “known standard” method. This technique was primarily tested through simulations of 1000 g U{sub 3}O{sub 8} samples using the Monte Carlo N-Particle eXtended (MCNPX) code. The results of these simulations showed good agreement between the simulated and exact {sup 235}U sample masses.

  18. Comparison of plate counts, Petrifilm, dipslides, and adenosine triphosphate bioluminescence for monitoring bacteria in cooling-tower waters.

    Science.gov (United States)

    Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C

    2009-04-01

    Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor

  19. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  20. SPERM COUNT DISTRIBUTIONS IN FERTILE MEN

    Science.gov (United States)

    Sperm concentration and count are often used as indicators of environmental impacts on male reproductive health. Existing clinical databases may be biased towards subfertile men with low sperm counts and less is known about expected sperm count distributions in cohorts of fertil...

  1. The Dependence of Tropical Cyclone Count and Size on Rotation Rate

    Science.gov (United States)

    Chavas, D. R.; Reed, K. A.

    2017-12-01

    Both theory and idealized equilibrium modeling studies indicate that tropical cyclone size decreases with background rotation rate. In contrast, in real-world observations size tends to increase with latitude. Here we seek to resolve this apparent contradiction via a set of reduced-complexity global aquaplanet simulations with varying planetary rotation rates using the NCAR Community Atmosphere Model 5. The latitudinal distribution of both storm count and size are found to vary markedly with rotation rate, yielding insight into the dynamical constraints on tropical cyclone activity on a rotating planet. Moreover, storm size is found to vary non-monotonically with latitude, indicating that non-equilibrium effects are crucial to the life-cycle evolution of size in nature. Results are then compared to experiments in idealized, time-dependent limited-area modeling simulations using CM1 in axisymmetric and three-dimensional geometry. Taken together, this hierarchy of models is used to quantify the role of equilibrium versus transient controls on storm size and the relevance of each to real storms in nature.

  2. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  3. Total bacterial count and somatic cell count in refrigerated raw milk stored in communal tanks

    Directory of Open Access Journals (Sweden)

    Edmar da Costa Alves

    2014-09-01

    Full Text Available The current industry demand for dairy products with extended shelf life has resulted in new challenges for milk quality maintenance. The processing of milk with high bacterial counts compromises the quality and performance of industrial products. The study aimed to evaluate the total bacteria counts (TBC and somatic cell count (SCC in 768 samples of refrigerated raw milk, from 32 communal tanks. Samples were collected in the first quarter of 2010, 2011, 2012 and 2013 and analyzed by the Laboratory of Milk Quality - LQL. Results showed that 62.5%, 37.5%, 15.6% and 27.1% of the means for TBC in 2010, 2011, 2012 and 2013, respectively, were above the values established by legislation. However, we observed a significant reduction in the levels of total bacterial count (TBC in the studied periods. For somatic cell count, 100% of the means indicated values below 600.000 cells/mL, complying with the actual Brazilian legislation. The values found for the somatic cell count suggests the adoption of effective measures for the sanitary control of the herd. However, the results must be considered with caution as it highlights the need for quality improvements of the raw material until it achieves reliable results effectively.

  4. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  5. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  6. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  7. Comparison of multinomial and binomial proportion methods for analysis of multinomial count data.

    Science.gov (United States)

    Galyean, M L; Wester, D B

    2010-10-01

    Simulation methods were used to generate 1,000 experiments, each with 3 treatments and 10 experimental units/treatment, in completely randomized (CRD) and randomized complete block designs. Data were counts in 3 ordered or 4 nominal categories from multinomial distributions. For the 3-category analyses, category probabilities were 0.6, 0.3, and 0.1, respectively, for 2 of the treatments, and 0.5, 0.35, and 0.15 for the third treatment. In the 4-category analysis (CRD only), probabilities were 0.3, 0.3, 0.2, and 0.2 for treatments 1 and 2 vs. 0.4, 0.4, 0.1, and 0.1 for treatment 3. The 3-category data were analyzed with generalized linear mixed models as an ordered multinomial distribution with a cumulative logit link or by regrouping the data (e.g., counts in 1 category/sum of counts in all categories), followed by analysis of single categories as binomial proportions. Similarly, the 4-category data were analyzed as a nominal multinomial distribution with a glogit link or by grouping data as binomial proportions. For the 3-category CRD analyses, empirically determined type I error rates based on pair-wise comparisons (F- and Wald chi(2) tests) did not differ between multinomial and individual binomial category analyses with 10 (P = 0.38 to 0.60) or 50 (P = 0.19 to 0.67) sampling units/experimental unit. When analyzed as binomial proportions, power estimates varied among categories, with analysis of the category with the greatest counts yielding power similar to the multinomial analysis. Agreement between methods (percentage of experiments with the same results for the overall test for treatment effects) varied considerably among categories analyzed and sampling unit scenarios for the 3-category CRD analyses. Power (F-test) was 24.3, 49.1, 66.9, 83.5, 86.8, and 99.7% for 10, 20, 30, 40, 50, and 100 sampling units/experimental unit for the 3-category multinomial CRD analyses. Results with randomized complete block design simulations were similar to those with the CRD

  8. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  9. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    Science.gov (United States)

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  10. An Adaptive Smoother for Counting Measurements

    International Nuclear Information System (INIS)

    Kondrasovs Vladimir; Coulon Romain; Normand Stephane

    2013-06-01

    Counting measurements associated with nuclear instruments are tricky to carry out due to the stochastic process of the radioactivity. Indeed events counting have to be processed and filtered in order to display a stable count rate value and to allow variations monitoring in the measured activity. Smoothers (as the moving average) are adjusted by a time constant defined as a compromise between stability and response time. A new approach has been developed and consists in improving the response time while maintaining count rate stability. It uses the combination of a smoother together with a detection filter. A memory of counting data is processed to calculate several count rate estimates using several integration times. These estimates are then sorted into the memory from short to long integration times. A measurement position, in terms of integration time, is then chosen into this memory after a detection test. An inhomogeneity into the Poisson counting process is detected by comparison between current position estimate and the other estimates contained into the memory in respect with the associated statistical variance calculated with homogeneous assumption. The measurement position (historical time) and the ability to forget an obsolete data or to keep in memory a useful data are managed using the detection test result. The proposed smoother is then an adaptive and a learning algorithm allowing an optimization of the response time while maintaining measurement counting stability and converging efficiently to the best counting estimate after an effective change in activity. This algorithm has also the specificity to be low recursive and thus easily embedded into DSP electronics based on FPGA or micro-controllers meeting 'real life' time requirements. (authors)

  11. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  12. A mind you can count on: validating breath counting as a behavioral measure of mindfulness

    Directory of Open Access Journals (Sweden)

    Daniel B Levinson

    2014-10-01

    Full Text Available Mindfulness practice of present moment awareness promises many benefits, but has eluded rigorous behavioral measurement. To date, research has relied on self-reported mindfulness or heterogeneous mindfulness trainings to infer skillful mindfulness practice and its effects. In four independent studies with over 400 total participants, we present the first construct validation of a behavioral measure of mindfulness, breath counting. We found it was reliable, correlated with self-reported mindfulness, differentiated long-term meditators from age-matched controls, and was distinct from sustained attention and working memory measures. In addition, we employed breath counting to test the nomological network of mindfulness. As theorized, we found skill in breath counting associated with more meta-awareness, less mind wandering, better mood, and greater nonattachment (i.e. less attentional capture by distractors formerly paired with reward. We also found in a randomized online training study that 4 weeks of breath counting training improved mindfulness and decreased mind wandering relative to working memory training and no training controls. Together, these findings provide the first evidence for breath counting as a behavioral measure of mindfulness.

  13. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  14. Flow cytometric assessment of activation of peripheral blood platelets in dogs with normal platelet count and asymptomatic thrombocytopenia.

    Science.gov (United States)

    Żmigrodzka, M; Guzera, M; Winnicka, A

    2016-01-01

    Platelets play a crucial role in hemostasis. Their activation has not yet been evaluated in healthy dogs with a normal and low platelet count. The aim of this study was to determine the influence of activators on platelet activation in dogs with a normal platelet count and asymptomatic thrombocytopenia. 72 clinically healthy dogs were enrolled. Patients were allocated into three groups. Group 1 consisted of 30 dogs with a normal platelet count, group 2 included 22 dogs with a platelet count between 100 and 200×109/l and group 3 consisted of 20 dogs with a platelet count lower than 100×109/l. Platelet rich-plasma (PRP) was obtained from peripheral blood samples using tripotassium ethylenediaminetetraacetic acid (K3-EDTA) as anticoagulant. Next, platelets were stimulated using phorbol-12-myristate-13-acetate or thrombin, stabilized using procaine or left unstimulated. The expression of CD51 and CD41/CD61 was evaluated. Co-expression of CD41/CD61 and Annexin V served as a marker of platelet activation. The expression of CD41/CD61 and CD51 did not differ between the 3 groups. Thrombin-stimulated platelets had a significantly higher activity in dogs with a normal platelet count than in dogs with asymptomatic thrombocytopenia. Procaine inhibited platelet activity in all groups. In conclusion, activation of platelets of healthy dogs in vitro varied depending on the platelet count and platelet activator.

  15. Advanced MRI assessment to predict benefit of anti-programmed cell death 1 protein immunotherapy response in patients with recurrent glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Lei [Dana-Farber Cancer Institute, Department of Imaging, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States); Li, Xiang; Qu, Jinrong [Affiliated Cancer Hospital of Zhengzhou University, Department of Radiology, Zhengzhou, Henan (China); Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Stroiney, Amanda [Dana-Farber Cancer Institute, Department of Imaging, Boston, MA (United States); Northeastern University, Department of Behavioral Neuroscience, College of Sciences, Boston, MA (United States); Helgager, Jeffrey [Brigham and Women' s Hospital, Department of Pathology, Boston, MA (United States); Reardon, David A. [Dana-Farber Cancer Institute, CenterforNeuro-Oncology, Boston, MA (United States); Department of Medicine, Boston, MA (United States); Young, Geoffrey S. [Harvard Medical School, Department of Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States)

    2017-02-15

    We describe the imaging findings encountered in GBM patients receiving immune checkpoint blockade and assess the potential of quantitative MRI biomarkers to differentiate patients who derive therapeutic benefit from those who do not. A retrospective analysis was performed on longitudinal MRIs obtained on recurrent GBM patients enrolled on clinical trials. Among 10 patients with analyzable data, bidirectional diameters were measured on contrast enhanced T1 (pGd-T1WI) and volumes of interest (VOI) representing measurable abnormality suggestive of tumor were selected on pGdT1WI (pGdT1 VOI), FLAIR-T2WI (FLAIR VOI), and ADC maps. Intermediate ADC (IADC) VOI represented voxels within the FLAIR VOI having ADC in the range of highly cellular tumor (0.7-1.1 x 10{sup -3} mm{sup 2}/s) (IADC VOI). Therapeutic benefit was determined by tissue pathology and survival on trial. IADC VOI, pGdT1 VOI, FLAIR VOI, and RANO assessment results were correlated with patient benefit. Five patients were deemed to have received therapeutic benefit and the other five patients did not. The average time on trial for the benefit group was 194 days, as compared to 81 days for the no benefit group. IADC VOI correlated well with the presence or absence of clinical benefit in 10 patients. Furthermore, pGd VOI, FLAIR VOI, and RANO assessment correlated less well with response. MRI reveals an initial increase in volumes of abnormal tissue with contrast enhancement, edema, and intermediate ADC suggesting hypercellularity within the first 0-6 months of immunotherapy. Subsequent stabilization and improvement in IADC VOI appear to better predict ultimate therapeutic benefit from these agents than conventional imaging. (orig.)

  16. Acute effects of electronic and tobacco cigarette smoking on complete blood count.

    Science.gov (United States)

    Flouris, Andreas D; Poulianiti, Konstantina P; Chorti, Maria S; Jamurtas, Athanasios Z; Kouretas, Dimitrios; Owolabi, Emmanuel O; Tzatzarakis, Manolis N; Tsatsakis, Aristidis M; Koutedakis, Yiannis

    2012-10-01

    The World Health Organisation called for research assessing the safety of electronic cigarette (e-cigarette). We evaluated the acute effect of active and passive e-cigarette and tobacco cigarette smoking on complete blood count (CBC) markers in 15 smokers and 15 never-smokers, respectively. Smokers underwent a control session, an active tobacco cigarette smoking session, and an active e-cigarette smoking session. Never-smokers underwent a control session, a passive tobacco cigarette smoking session, and a passive e-cigarette smoking session. The results demonstrated that CBC indices remained unchanged during the control session and the active and passive e-cigarette smoking sessions (P>0.05). Active and passive tobacco cigarette smoking increased white blood cell, lymphocyte, and granulocyte counts for at least one hour in smokers and never smokers (Pissues and other areas of consumer product safety of e-cigarettes, because the nicotine content in the liquids used may vary considerably. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  18. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  19. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  20. Calculating potential error in sodium MRI with respect to the analysis of small objects.

    Science.gov (United States)

    Stobbe, Robert W; Beaulieu, Christian

    2018-06-01

    To facilitate correct interpretation of sodium MRI measurements, calculation of error with respect to rapid signal decay is introduced and combined with that of spatially correlated noise to assess volume-of-interest (VOI) 23 Na signal measurement inaccuracies, particularly for small objects. Noise and signal decay-related error calculations were verified using twisted projection imaging and a specially designed phantom with different sized spheres of constant elevated sodium concentration. As a demonstration, lesion signal measurement variation (5 multiple sclerosis participants) was compared with that predicted from calculation. Both theory and phantom experiment showed that VOI signal measurement in a large 10-mL, 314-voxel sphere was 20% less than expected on account of point-spread-function smearing when the VOI was drawn to include the full sphere. Volume-of-interest contraction reduced this error but increased noise-related error. Errors were even greater for smaller spheres (40-60% less than expected for a 0.35-mL, 11-voxel sphere). Image-intensity VOI measurements varied and increased with multiple sclerosis lesion size in a manner similar to that predicted from theory. Correlation suggests large underestimation of 23 Na signal in small lesions. Acquisition-specific measurement error calculation aids 23 Na MRI data analysis and highlights the limitations of current low-resolution methodologies. Magn Reson Med 79:2968-2977, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  2. Equivalence of truncated count mixture distributions and mixtures of truncated count distributions.

    Science.gov (United States)

    Böhning, Dankmar; Kuhnert, Ronny

    2006-12-01

    This article is about modeling count data with zero truncation. A parametric count density family is considered. The truncated mixture of densities from this family is different from the mixture of truncated densities from the same family. Whereas the former model is more natural to formulate and to interpret, the latter model is theoretically easier to treat. It is shown that for any mixing distribution leading to a truncated mixture, a (usually different) mixing distribution can be found so that the associated mixture of truncated densities equals the truncated mixture, and vice versa. This implies that the likelihood surfaces for both situations agree, and in this sense both models are equivalent. Zero-truncated count data models are used frequently in the capture-recapture setting to estimate population size, and it can be shown that the two Horvitz-Thompson estimators, associated with the two models, agree. In particular, it is possible to achieve strong results for mixtures of truncated Poisson densities, including reliable, global construction of the unique NPMLE (nonparametric maximum likelihood estimator) of the mixing distribution, implying a unique estimator for the population size. The benefit of these results lies in the fact that it is valid to work with the mixture of truncated count densities, which is less appealing for the practitioner but theoretically easier. Mixtures of truncated count densities form a convex linear model, for which a developed theory exists, including global maximum likelihood theory as well as algorithmic approaches. Once the problem has been solved in this class, it might readily be transformed back to the original problem by means of an explicitly given mapping. Applications of these ideas are given, particularly in the case of the truncated Poisson family.

  3. Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

    Science.gov (United States)

    Ahmad, Moiz; Balter, Peter; Pan, Tinsu

    2011-10-01

    Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4-6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3-8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm

  4. Blood Count Tests: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish WBC count (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Blood Count Tests ... WBC count Show More Show Less Related Health Topics Bleeding Disorders Blood Laboratory Tests National Institutes of ...

  5. Evaluation of lactate, white blood cell count, neutrophil count, procalcitonin and immature granulocyte count as biomarkers for sepsis in emergency department patients.

    Science.gov (United States)

    Karon, Brad S; Tolan, Nicole V; Wockenfus, Amy M; Block, Darci R; Baumann, Nikola A; Bryant, Sandra C; Clements, Casey M

    2017-11-01

    Lactate, white blood cell (WBC) and neutrophil count, procalcitonin and immature granulocyte (IG) count were compared for the prediction of sepsis, and severe sepsis or septic shock, in patients presenting to the emergency department (ED). We prospectively enrolled 501 ED patients with a sepsis panel ordered for suspicion of sepsis. WBC, neutrophil, and IG counts were measured on a Sysmex XT-2000i analyzer. Lactate was measured by i-STAT, and procalcitonin by Brahms Kryptor. We classified patients as having sepsis using a simplification of the 1992 consensus conference sepsis definitions. Patients with sepsis were further classified as having severe sepsis or septic shock using established criteria. Univariate receiver operating characteristic (ROC) analysis was performed to determine odds ratio (OR), area under the ROC curve (AUC), and sensitivity/specificity at optimal cut-off for prediction of sepsis (vs. no sepsis), and prediction of severe sepsis or septic shock (vs. no sepsis). There were 267 patients without sepsis; and 234 with sepsis, including 35 patients with severe sepsis or septic shock. Lactate had the highest OR (1.44, 95th% CI 1.20-1.73) for the prediction of sepsis; while WBC, neutrophil count and percent (neutrophil/WBC) had OR>1.00 (psepsis or septic shock, with an odds ratio (95th% CI) of 2.70 (2.02-3.61) and AUC 0.89 (0.82-0.96). Traditional biomarkers (lactate, WBC, neutrophil count, procalcitonin, IG) have limited utility in the prediction of sepsis. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Serum Copper Level Significantly Influences Platelet Count, Lymphocyte Count and Mean Cell Hemoglobin in Sickle Cell Anemia

    Directory of Open Access Journals (Sweden)

    Okocha Chide

    2015-12-01

    Full Text Available Background Changes in serum micro nutrients levels affect a number of critically important metabolic processes; these could potentially influence blood counts and ultimately disease presentation in patients with sickle cell anemia (SCA. Objectives To evaluate the influence of serum micro-nutrients levels; zinc, copper, selenium and magnesium on blood counts in steady state SCA patients. Methods A cross sectional study that involved 28 steady state adult SCA subjects. Seven milliliters (mls of blood was collected; 3 mls was for hemoglobin electrophoresis and full blood count determination while 4 mls was for measurement of serum micro nutrients levels, by the atomic absorption spectrophotometry. Correlation between serum micro-nutrient levels and blood counts was done by the Pearson’s linear regression. Ethical approval was obtained from the institutional review board and each participant gave informed consent. All data was analyzed by SPSS software version 20. Results There was a significant correlation between serum copper levels and mean cell hemoglobin (MCH, platelet and lymphocyte counts (r = 0.418; P = 0.02, r = -0.376; P = 0.04 and r = -0.383; P = 0.04, respectively. There were no significant correlations between serum levels of other micro nutrients (selenium, zinc and magnesium and blood counts. Conclusions Copper influences blood count in SCA patients probably by inducing red cell haemolysis, oxidant tissue damage and stimulating the immune system.

  7. Peripheral blood leukocyte count as an index of defense status in the leukopenic host

    International Nuclear Information System (INIS)

    Cawley, S.; Findon, G.; Miller, T.E.

    1988-01-01

    These experimental studies have investigated the reliability of the peripheral blood leukocyte count to predict whether the leukopenic host can contain or eliminate infection. Additionally, we have investigated the possibility that determination of leukocyte recruitment, supplementary to peripheral blood leukocyte counts, might allow individuals with neutropenia at risk from serious infection to be distinguished with greater certainty. Varying doses of radiation, cyclophosphamide, and methylprednisolone were used to induce distinct levels of leukopenia in rats. Leukocyte recruitment was measured by quantifying the response of neutropenic animals to evocative, subcutaneous stimuli, and the results of this assay were then compared with circulating leukocyte counts in the same individuals. Six models of experimentally induced infection were used to compare circulating and recruitable leukocytes as indicators of the susceptibility of the leukopenic host to infection. Response curves relating leukocyte numbers to host resistance were similar when circulating or recruitable leukocytes were used as an index of defense capability. These findings support the use of peripheral blood leukocyte numbers as an index of resistance to infection in individuals with leukopenia and suggest that functional analyses such as leukocyte recruitment are unlikely to provide additional information

  8. A new approach for improving diagnostic accuracy in Alzheimer's disease and frontal lobe dementia utilising the intrinsic properties of the SPET dataset

    Energy Technology Data Exchange (ETDEWEB)

    Pagani, Marco [Institute of Cognitive Sciences and Technology, CNR, Viale Marx 15, 00137, Rome (Italy); Section of Nuclear Medicine, Karolinska Hospital/Institute, Stockholm (Sweden); Kovalev, Vassili A. [Institute of Engineering Cybernetics, Belarus National Academy of Sciences, Minsk (Belarus); Max-Planck Institute of Cognitive Neuroscience, Leipzig (Germany); Lundqvist, Roger; Thurfjell, Lennart [Applied Medical Imaging, Uppsala (Sweden); Jacobsson, Hans [Section of Nuclear Medicine, Karolinska Hospital/Institute, Stockholm (Sweden); Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Larsson, Stig A. [Section of Nuclear Medicine, Karolinska Hospital/Institute, Stockholm (Sweden)

    2003-11-01

    Alzheimer's disease (AD) and frontal lobe dementia (FLD) show characteristic patterns of regional cerebral blood flow (rCBF). However, these patterns may overlap with those observed in the aging brain in elderly normal individuals. The aim of this study was to develop a new method for better classification and recognition of AD and FLD cases as compared with normal controls. Forty-six patients with AD, 7 patients with FLD and 34 normal controls (CTR) were included in the study. rCBF was assessed by technetium-99m hexamethylpropylene amine oxime and a three-headed single-photon emission tomography (SPET) camera. A brain atlas was used to define volumes of interest (VOIs) corresponding to the brain lobes. In addition to conventional image processing methods, based on count density/voxel, the new approach also analysed other intrinsic properties of the data by means of gradient computation steps. Hereby, five factors were assessed and tested separately: the mean count density/voxel and its histogram, the mean gradient and its histogram, and the gradient angle co-occurrence matrix. A feature vector concatenating single features was also created and tested. Preliminary feature discrimination was performed using a two-sided t-test and a K-means clustering was then used to classify the image sets into categories. Finally, five-dimensional co-occurrence matrices combining the different intrinsic properties were computed for each VOI, and their ability to recognise the group to which each individual scan belonged was investigated. For correct classification of the AD-CTR groups, the gradient histogram in the parieto-temporal lobes was the most useful single feature (accuracy 91%). FLD and CTR were better classified by the count density/voxel histogram (frontal and occipital lobes) and by the mean gradient (frontal, temporal and parietal lobes, accuracy 98%). For AD and FLD the count density/voxel histogram in the frontal, parietal and occipital lobes classified the

  9. A new approach for improving diagnostic accuracy in Alzheimer's disease and frontal lobe dementia utilising the intrinsic properties of the SPET dataset

    International Nuclear Information System (INIS)

    Pagani, Marco; Kovalev, Vassili A.; Lundqvist, Roger; Thurfjell, Lennart; Jacobsson, Hans; Larsson, Stig A.

    2003-01-01

    Alzheimer's disease (AD) and frontal lobe dementia (FLD) show characteristic patterns of regional cerebral blood flow (rCBF). However, these patterns may overlap with those observed in the aging brain in elderly normal individuals. The aim of this study was to develop a new method for better classification and recognition of AD and FLD cases as compared with normal controls. Forty-six patients with AD, 7 patients with FLD and 34 normal controls (CTR) were included in the study. rCBF was assessed by technetium-99m hexamethylpropylene amine oxime and a three-headed single-photon emission tomography (SPET) camera. A brain atlas was used to define volumes of interest (VOIs) corresponding to the brain lobes. In addition to conventional image processing methods, based on count density/voxel, the new approach also analysed other intrinsic properties of the data by means of gradient computation steps. Hereby, five factors were assessed and tested separately: the mean count density/voxel and its histogram, the mean gradient and its histogram, and the gradient angle co-occurrence matrix. A feature vector concatenating single features was also created and tested. Preliminary feature discrimination was performed using a two-sided t-test and a K-means clustering was then used to classify the image sets into categories. Finally, five-dimensional co-occurrence matrices combining the different intrinsic properties were computed for each VOI, and their ability to recognise the group to which each individual scan belonged was investigated. For correct classification of the AD-CTR groups, the gradient histogram in the parieto-temporal lobes was the most useful single feature (accuracy 91%). FLD and CTR were better classified by the count density/voxel histogram (frontal and occipital lobes) and by the mean gradient (frontal, temporal and parietal lobes, accuracy 98%). For AD and FLD the count density/voxel histogram in the frontal, parietal and occipital lobes classified the groups

  10. Evaluation of elastix-based propagated align algorithm for VOI- and voxel-based analysis of longitudinal (18)F-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC).

    Science.gov (United States)

    Kerner, Gerald Sma; Fischer, Alexander; Koole, Michel Jb; Pruim, Jan; Groen, Harry Jm

    2015-01-01

    Deformable image registration allows volume of interest (VOI)- and voxel-based analysis of longitudinal changes in fluorodeoxyglucose (FDG) tumor uptake in patients with non-small cell lung cancer (NSCLC). This study evaluates the performance of the elastix toolbox deformable image registration algorithm for VOI and voxel-wise assessment of longitudinal variations in FDG tumor uptake in NSCLC patients. Evaluation of the elastix toolbox was performed using (18)F-FDG PET/CT at baseline and after 2 cycles of therapy (follow-up) data in advanced NSCLC patients. The elastix toolbox, an integrated part of the IMALYTICS workstation, was used to apply a CT-based non-linear image registration of follow-up PET/CT data using the baseline PET/CT data as reference. Lesion statistics were compared to assess the impact on therapy response assessment. Next, CT-based deformable image registration was performed anew on the deformed follow-up PET/CT data using the original follow-up PET/CT data as reference, yielding a realigned follow-up PET dataset. Performance was evaluated by determining the correlation coefficient between original and realigned follow-up PET datasets. The intra- and extra-thoracic tumors were automatically delineated on the original PET using a 41% of maximum standardized uptake value (SUVmax) adaptive threshold. Equivalence between reference and realigned images was tested (determining 95% range of the difference) and estimating the percentage of voxel values that fell within that range. Thirty-nine patients with 191 tumor lesions were included. In 37/39 and 12/39 patients, respectively, thoracic and non-thoracic lesions were evaluable for response assessment. Using the EORTC/SUVmax-based criteria, 5/37 patients had a discordant response of thoracic, and 2/12 a discordant response of non-thoracic lesions between the reference and the realigned image. FDG uptake values of corresponding tumor voxels in the original and realigned reference PET correlated well (R

  11. Correction for decay during counting in gamma spectrometry

    International Nuclear Information System (INIS)

    Nir-El, Y.

    2013-01-01

    A basic result in gamma spectrometry is the count rate of a relevant peak. Correction for decay during counting and expressing the count rate at the beginning of the measurement can be done by a multiplicative factor that is derived from integrating the count rate over time. The counting time substituted in this factor must be the live time, whereas the use of the real-time is an error that underestimates the count rate by about the dead-time (DT) (in percentage). This error of underestimation of the count rate is corroborated in the measurement of a nuclide with a high DT. The present methodology is not applicable in systems that include a zero DT correction function. (authors)

  12. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  13. Total lymphocyte count as a substitute to cd4 count in management of hiv infected individuals in resource limited society

    International Nuclear Information System (INIS)

    Daud, M.Y.; Qazi, R.A.

    2015-01-01

    Pakistan is a resource limited society and gold standard parameters to monitor HIV disease activity are very costly. The objective of the study was to evaluate total lymphocyte count (TLC) as a surrogate to CD4 count to monitor disease activity in HIV/AIDS in resource limited society. Methods: This cross sectional study was carried out at HIV/AIDS treatment centre, Pakistan Institute of Medical Sciences (PIMS), Islamabad. A total of seven hundred and seventy four (774) HIV positive patients were enrolled in this study, and their CD4 count and total lymphocyte count were checked to find any correlation between the two by using Spearman ranked correlation coefficient. Results: The mean CD4 count was (434.30 ± 269.23), with minimum CD4 count of (9.00), and maximum of (1974.00). The mean total lymphocyte count (TLC) was (6764.0052 ± 2364.02) with minimum TLC (1200.00) and maximum TLC was (20200.00). Using the Pearson's correlation (r) there was a significant and positive correlation between TLC and CD4 count. (r2=0.127 and p=0.000) at 0.01 level. Conclusion: Our study showed a significant positive correlation between CD4 count and total lymphocyte count (TLC), so TLC can be used as a marker of disease activity in HIV infected patients. (author)

  14. Comparison of dynamic monitoring strategies based on CD4 cell counts in virally suppressed, HIV-positive individuals on combination antiretroviral therapy in high-income countries: a prospective, observational study

    NARCIS (Netherlands)

    Caniglia, Ellen C.; Cain, Lauren E.; Sabin, Caroline A.; Robins, James M.; Logan, Roger; Abgrall, Sophie; Mugavero, Michael J.; Hernández-Díaz, Sonia; Meyer, Laurence; Seng, Remonie; Drozd, Daniel R.; Seage, George R.; Bonnet, Fabrice; Dabis, Francois; Moore, Richard D.; Reiss, Peter; van Sighem, Ard; Mathews, William C.; del Amo, Julia; Moreno, Santiago; Deeks, Steven G.; Muga, Roberto; Boswell, Stephen L.; Ferrer, Elena; Eron, Joseph J.; Napravnik, Sonia; Jose, Sophie; Phillips, Andrew; Justice, Amy C.; Tate, Janet P.; Gill, John; Pacheco, Antonio; Veloso, Valdilea G.; Bucher, Heiner C.; Egger, Matthias; Furrer, Hansjakob; Porter, Kholoud; Touloumi, Giota; Crane, Heidi; Miro, Jose M.; Sterne, Jonathan A.; Costagliola, Dominique; Saag, Michael; Hernán, Miguel A.

    2017-01-01

    Clinical guidelines vary with respect to the optimal monitoring frequency of HIV-positive individuals. We compared dynamic monitoring strategies based on time-varying CD4 cell counts in virologically suppressed HIV-positive individuals. In this observational study, we used data from prospective

  15. A Review of Multivariate Distributions for Count Data Derived from the Poisson Distribution.

    Science.gov (United States)

    Inouye, David; Yang, Eunho; Allen, Genevera; Ravikumar, Pradeep

    2017-01-01

    The Poisson distribution has been widely studied and used for modeling univariate count-valued data. Multivariate generalizations of the Poisson distribution that permit dependencies, however, have been far less popular. Yet, real-world high-dimensional count-valued data found in word counts, genomics, and crime statistics, for example, exhibit rich dependencies, and motivate the need for multivariate distributions that can appropriately model this data. We review multivariate distributions derived from the univariate Poisson, categorizing these models into three main classes: 1) where the marginal distributions are Poisson, 2) where the joint distribution is a mixture of independent multivariate Poisson distributions, and 3) where the node-conditional distributions are derived from the Poisson. We discuss the development of multiple instances of these classes and compare the models in terms of interpretability and theory. Then, we empirically compare multiple models from each class on three real-world datasets that have varying data characteristics from different domains, namely traffic accident data, biological next generation sequencing data, and text data. These empirical experiments develop intuition about the comparative advantages and disadvantages of each class of multivariate distribution that was derived from the Poisson. Finally, we suggest new research directions as explored in the subsequent discussion section.

  16. Application of high intensity ultrasound treatment on Enterobacteriae count in milk

    Directory of Open Access Journals (Sweden)

    Anet Režek Jambrak

    2011-06-01

    Full Text Available Ultrasonication is a non-thermal method of food preservation that has the advantage of inactivating microbes in food without causing the common side-effects associated with conventional heat treatments, such as nutrient and flavour loss. In this work high intensity ultrasound was used to investigate inactivation Enterobacteriae count in raw milk. Raw milk with 4% of milk fat was treated with ultrasonic probe that was 12 mm in diameter and with 20 kHz frequency immerged in milk directly. For ultrasounds treatment, three parameters varied according to the statistical experimental design. Centre composite design was used to optimize and design experimental parameters: temperature (20, 40 and 60 °C, amplitude (120, 90 and 60 μm and time (6, 9 and 12 minutes. All analyses were performed immediately after sonication and after 3 and 5 days of storage in refrigeration at 4 °C. The facts that substantially affect the inactivation of microorganisms using ultrasound are the amplitude of the ultrasonic waves, the exposure/contact time with the microorganisms, and the temperatureof treatment. The achieved results indicate significant inactivation of microorganisms under longer period of treatments with ultrasonic probe particularly in combination with higher temperature andamplitude. Output optimal value of Enterobacteriae count has been defined by Statgraphics where lowest Enterobacteriae count (1.06151 log CFU mL-1 was as follows for specific ultrasound parameters: amplitude of 120 μm, treatment time for 12 min and temperature of 60 °C.

  17. A counting-card circuit based on PCI bus

    International Nuclear Information System (INIS)

    Shi Jing; Li Yong; Chinese Academy of Sciences, Lanzhou; Su Hong; Dong Chengfu; Li Xiaogang; Ma Xiaoli

    2004-01-01

    A counting-card circuit based on PCI bus that we developed recently used for advanced personal computer will be introduced in this paper briefly. The maximum count capacity of this counting-card is 10 9 -1, ranging from 0 to 999 999 999, the maximum counting time range, 1 x 10 6 s, can be set in 1 cycle, the maximum counting rate is 20 MHz for positive input. (authors)

  18. TU-FG-209-03: Exploring the Maximum Count Rate Capabilities of Photon Counting Arrays Based On Polycrystalline Silicon

    Energy Technology Data Exchange (ETDEWEB)

    Liang, A K; Koniczek, M; Antonuk, L E; El-Mohri, Y; Zhao, Q [University of Michigan, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailed circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit

  19. Recursive algorithms for phylogenetic tree counting.

    Science.gov (United States)

    Gavryushkina, Alexandra; Welch, David; Drummond, Alexei J

    2013-10-28

    In Bayesian phylogenetic inference we are interested in distributions over a space of trees. The number of trees in a tree space is an important characteristic of the space and is useful for specifying prior distributions. When all samples come from the same time point and no prior information available on divergence times, the tree counting problem is easy. However, when fossil evidence is used in the inference to constrain the tree or data are sampled serially, new tree spaces arise and counting the number of trees is more difficult. We describe an algorithm that is polynomial in the number of sampled individuals for counting of resolutions of a constraint tree assuming that the number of constraints is fixed. We generalise this algorithm to counting resolutions of a fully ranked constraint tree. We describe a quadratic algorithm for counting the number of possible fully ranked trees on n sampled individuals. We introduce a new type of tree, called a fully ranked tree with sampled ancestors, and describe a cubic time algorithm for counting the number of such trees on n sampled individuals. These algorithms should be employed for Bayesian Markov chain Monte Carlo inference when fossil data are included or data are serially sampled.

  20. Approaches for modeling within subject variability in pharmacometric count data analysis: dynamic inter-occasion variability and stochastic differential equations.

    Science.gov (United States)

    Deng, Chenhui; Plan, Elodie L; Karlsson, Mats O

    2016-06-01

    Parameter variation in pharmacometric analysis studies can be characterized as within subject parameter variability (WSV) in pharmacometric models. WSV has previously been successfully modeled using inter-occasion variability (IOV), but also stochastic differential equations (SDEs). In this study, two approaches, dynamic inter-occasion variability (dIOV) and adapted stochastic differential equations, were proposed to investigate WSV in pharmacometric count data analysis. These approaches were applied to published count models for seizure counts and Likert pain scores. Both approaches improved the model fits significantly. In addition, stochastic simulation and estimation were used to explore further the capability of the two approaches to diagnose and improve models where existing WSV is not recognized. The results of simulations confirmed the gain in introducing WSV as dIOV and SDEs when parameters vary randomly over time. Further, the approaches were also informative as diagnostics of model misspecification, when parameters changed systematically over time but this was not recognized in the structural model. The proposed approaches in this study offer strategies to characterize WSV and are not restricted to count data.

  1. SELECTION : Les variétés hybrides sont-elles justifiées ?

    Directory of Open Access Journals (Sweden)

    Gallais André

    2000-01-01

    Full Text Available Jean-Pierre Berlan, en 1999, a critiqué le choix de la voie hybride chez le maïs [1]. Cependant, il ne dit pas ce qu’il aurait fallu faire comme type de variétés pour avoir le même progrès économique dans la culture du maïs. Chez cette espèce, le clonage étant exclu, si ce n’est pas la voie lignée, c’est la voie population. Nous allons donc comparer ces deux voies à la voie hybride. Pour cela, nous allons d’abord nous placer dans le cas où les effets des gènes sont tels qu’ils permettent, en théorie, d’obtenir des lignées aussi bonnes que les hybrides, c’est-à-dire qu’il n’y a pas d’avantage de l’état hétérozygote à un locus (encadré 1. Il est en effet évident que s’il y a des mécanismes génétiques qui font que l’état hétérozygote à un locus est meilleur que l’état homozygote (on dit qu’il y a superdominance, alors il faudra développer des hybrides. Nous montrerons que, même en dehors de cette situation, la voie hybride est la seule qui puisse apporter le maximum de rendement et de marge brute à l’hectare, et cela pendant un temps assez long (plus d’un siècle. Nous considérerons le cas de superdominance, ou de situations apparentées, dans une seconde étape.

  2. Seismic Imaging of the Lesser Antilles Subduction Zone Using S-to-P Receiver Functions: Insights From VoiLA

    Science.gov (United States)

    Chichester, B.; Rychert, C.; Harmon, N.; Rietbrock, A.; Collier, J.; Henstock, T.; Goes, S. D. B.; Kendall, J. M.; Krueger, F.

    2017-12-01

    In the Lesser Antilles subduction zone Atlantic oceanic lithosphere, expected to be highly hydrated, is being subducted beneath the Caribbean plate. Water and other volatiles from the down-going plate are released and cause the overlying mantle to melt, feeding volcanoes with magma and hence forming the volcanic island arc. However, the depths and pathways of volatiles and melt within the mantle wedge are not well known. Here, we use S-to-P receiver functions to image seismic velocity contrasts with depth within the subduction zone in order to constrain the release of volatiles and the presence of melt in the mantle wedge, as well as slab structure and arc-lithosphere structure. We use data from 55-80° epicentral distances recorded by 32 recovered broadband ocean-bottom seismometers that were deployed during the 2016-2017 Volatiles in the Lesser Antilles (VoiLA) project for 15 months on the back- and fore-arc. The S-to-P receiver functions are calculated using two methods: extended time multi-taper deconvolution followed by migration to depth to constrain 3-D discontinuity structure of the subduction zone; and simultaneous deconvolution to determine structure beneath single stations. In the south of the island arc, we image a velocity increase with depth associated with the Moho at depths of 32-40 ± 4 km on the fore- and back-arc, consistent with various previous studies. At depths of 65-80 ± 4 km beneath the fore-arc we image a strong velocity decrease with depth that is west-dipping. At 96-120 ± 5 km beneath the fore-arc, we image a velocity increase with depth that is also west-dipping. The dipping negative-positive phase could represent velocity contrasts related to the top of the down-going plate, a feature commonly imaged in subduction zone receiver function studies. The negative phase is strong, so there may also be contributions to the negative velocity discontinuity from slab dehydration and/or mantle wedge serpentinization in the fore-arc.

  3. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  4. Latent segmentation based count models: Analysis of bicycle safety in Montreal and Toronto.

    Science.gov (United States)

    Yasmin, Shamsunnahar; Eluru, Naveen

    2016-10-01

    The study contributes to literature on bicycle safety by building on the traditional count regression models to investigate factors affecting bicycle crashes at the Traffic Analysis Zone (TAZ) level. TAZ is a traffic related geographic entity which is most frequently used as spatial unit for macroscopic crash risk analysis. In conventional count models, the impact of exogenous factors is restricted to be the same across the entire region. However, it is possible that the influence of exogenous factors might vary across different TAZs. To accommodate for the potential variation in the impact of exogenous factors we formulate latent segmentation based count models. Specifically, we formulate and estimate latent segmentation based Poisson (LP) and latent segmentation based Negative Binomial (LNB) models to study bicycle crash counts. In our latent segmentation approach, we allow for more than two segments and also consider a large set of variables in segmentation and segment specific models. The formulated models are estimated using bicycle-motor vehicle crash data from the Island of Montreal and City of Toronto for the years 2006 through 2010. The TAZ level variables considered in our analysis include accessibility measures, exposure measures, sociodemographic characteristics, socioeconomic characteristics, road network characteristics and built environment. A policy analysis is also conducted to illustrate the applicability of the proposed model for planning purposes. This macro-level research would assist decision makers, transportation officials and community planners to make informed decisions to proactively improve bicycle safety - a prerequisite to promoting a culture of active transportation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Platelet counting using the Coulter electronic counter.

    Science.gov (United States)

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  6. Automated uranium analysis by delayed-neutron counting

    International Nuclear Information System (INIS)

    Kunzendorf, H.; Loevborg, L.; Christiansen, E.M.

    1980-10-01

    Automated uranium analysis by fission-induced delayed-neutron counting is described. A short description is given of the instrumentation including transfer system, process control, irradiation and counting sites, and computer operations. Characteristic parameters of the facility (sample preparations, background, and standards) are discussed. A sensitivity of 817 +- 22 counts per 10 -6 g U is found using irradiation, delay, and counting times of 20 s, 5 s, and 10 s, respectively. Presicion is generally less than 1% for normal geological samples. Critical level and detection limits for 7.5 g samples are 8 and 16 ppb, respectively. The importance of some physical and elemental interferences are outlined. Dead-time corrections of measured count rates are necessary and a polynomical expression is used for count rates up to 10 5 . The presence of rare earth elements is regarded as the most important elemental interference. A typical application is given and other areas of application are described. (auther)

  7. Resonance ionization spectroscopy: Counting noble gas atoms

    International Nuclear Information System (INIS)

    Hurst, G.S.; Payne, M.G.; Chen, C.H.; Willis, R.D.; Lehmann, B.E.; Kramer, S.D.

    1981-01-01

    The purpose of this paper is to describe new work on the counting of noble gas atoms, using lasers for the selective ionization and detectors for counting individual particles (electrons or positive ions). When positive ions are counted, various kinds of mass analyzers (magnetic, quadrupole, or time-of-flight) can be incorporated to provide A selectivity. We show that a variety of interesting and important applications can be made with atom-counting techniques which are both atomic number (Z) and mass number (A) selective. (orig./FKS)

  8. The power of statistical tests using field trial count data of non-target organisms in enviromental risk assessment of genetically modified plants

    NARCIS (Netherlands)

    Voet, van der H.; Goedhart, P.W.

    2015-01-01

    Publications on power analyses for field trial count data comparing transgenic and conventional crops have reported widely varying requirements for the replication needed to obtain statistical tests with adequate power. These studies are critically reviewed and complemented with a new simulation

  9. Counting and Surveying Homeless Youth: Recommendations from YouthCount 2.0!, a Community-Academic Partnership.

    Science.gov (United States)

    Narendorf, Sarah C; Santa Maria, Diane M; Ha, Yoonsook; Cooper, Jenna; Schieszler, Christine

    2016-12-01

    Communities across the United States are increasing efforts to find and count homeless youth. This paper presents findings and lessons learned from a community/academic partnership to count homeless youth and conduct an in depth research survey focused on the health needs of this population. Over a 4 week recruitment period, 632 youth were counted and 420 surveyed. Methodological successes included an extended counting period, broader inclusion criteria to capture those in unstable housing, use of student volunteers in health training programs, recruiting from magnet events for high risk youth, and partnering with community agencies to disseminate findings. Strategies that did not facilitate recruitment included respondent driven sampling, street canvassing beyond known hotspots, and having community agencies lead data collection. Surveying was successful in gathering data on reasons for homelessness, history in public systems of care, mental health history and needs, sexual risk behaviors, health status, and substance use. Youth were successfully surveyed across housing types including shelters or transitional housing (n = 205), those in unstable housing such as doubled up with friends or acquaintances (n = 75), and those who were literally on the streets or living in a place not meant for human habitation (n = 140). Most youth completed the self-report survey and provided detailed information about risk behaviors. Recommendations to combine research data collection with counting are presented.

  10. Improving the counting efficiency in time-correlated single photon counting experiments by dead-time optimization

    Energy Technology Data Exchange (ETDEWEB)

    Peronio, P.; Acconcia, G.; Rech, I.; Ghioni, M. [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-11-15

    Time-Correlated Single Photon Counting (TCSPC) has been long recognized as the most sensitive method for fluorescence lifetime measurements, but often requiring “long” data acquisition times. This drawback is related to the limited counting capability of the TCSPC technique, due to pile-up and counting loss effects. In recent years, multi-module TCSPC systems have been introduced to overcome this issue. Splitting the light into several detectors connected to independent TCSPC modules proportionally increases the counting capability. Of course, multi-module operation also increases the system cost and can cause space and power supply problems. In this paper, we propose an alternative approach based on a new detector and processing electronics designed to reduce the overall system dead time, thus enabling efficient photon collection at high excitation rate. We present a fast active quenching circuit for single-photon avalanche diodes which features a minimum dead time of 12.4 ns. We also introduce a new Time-to-Amplitude Converter (TAC) able to attain extra-short dead time thanks to the combination of a scalable array of monolithically integrated TACs and a sequential router. The fast TAC (F-TAC) makes it possible to operate the system towards the upper limit of detector count rate capability (∼80 Mcps) with reduced pile-up losses, addressing one of the historic criticisms of TCSPC. Preliminary measurements on the F-TAC are presented and discussed.

  11. Hidden Markov models for zero-inflated Poisson counts with an application to substance use.

    Science.gov (United States)

    DeSantis, Stacia M; Bandyopadhyay, Dipankar

    2011-06-30

    Paradigms for substance abuse cue-reactivity research involve pharmacological or stressful stimulation designed to elicit stress and craving responses in cocaine-dependent subjects. It is unclear as to whether stress induced from participation in such studies increases drug-seeking behavior. We propose a 2-state Hidden Markov model to model the number of cocaine abuses per week before and after participation in a stress-and cue-reactivity study. The hypothesized latent state corresponds to 'high' or 'low' use. To account for a preponderance of zeros, we assume a zero-inflated Poisson model for the count data. Transition probabilities depend on the prior week's state, fixed demographic variables, and time-varying covariates. We adopt a Bayesian approach to model fitting, and use the conditional predictive ordinate statistic to demonstrate that the zero-inflated Poisson hidden Markov model outperforms other models for longitudinal count data. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Evaluation of standard and modified M-FC, MacConkey, and Teepol media for membrane filtration counting of fecal coliforms in water.

    Science.gov (United States)

    Grabow, W O; Hilner, C A; Coubrough, P

    1981-08-01

    MacConkey agar, standard M-FC agar, M-FC agar without rosolic acid, M-FC agar with a resuscitation top layer, Teepol agar, and pads saturated with Teepol broth, were evaluated as growth media for membrane filtration counting of fecal coliform bacteria in water. In comparative tests on 312 samples of water from a wide variety of sources, including chlorinated effluents, M-FC agar without rosolic acid proved the medium of choice because it generally yielded the highest counts, was readily obtainable, easy to prepare and handle, and yielded clearly recognizable fecal coliform colonies. Identification of 1,139 fecal coliform isolates showed that fecal coliform tests cannot be used to enumerate Escherichia coli because the incidence of E. coli among fecal coliforms varied from an average of 51% for river water to 93% for an activated sludge effluent after chlorination. The incidence of Klebsiella pneumoniae among fecal coliforms varied from an average of 4% for the activated sludge effluent after chlorination to 32% for the river water. The advantages of a standard membrane filtration procedure for routine counting of fecal coliforms in water using M-FC agar without rosolic acid as growth medium, in the absence of preincubation or resuscitation steps, are outlined.

  13. Bioassay method for Uranium in urine by Delay Neutron counting; Metoda Bioassay Uranium dalam urin dengan pencacahan Netron Kasip

    Energy Technology Data Exchange (ETDEWEB)

    Suratman,; Purwanto,; Sukarman-Aminjoyo, [Yogyakarta Nuclear Research Centre, National Atomic Energy Agency, Yogyakarta (Indonesia)

    1996-04-15

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 {mu}g.

  14. Variation in pre-treatment count lead time and its effect on baseline estimates of cage-level sea lice abundance.

    Science.gov (United States)

    Gautam, R; Boerlage, A S; Vanderstichel, R; Revie, C W; Hammell, K L

    2016-11-01

    Treatment efficacy studies typically use pre-treatment sea lice abundance as the baseline. However, the pre-treatment counting window often varies from the day of treatment to several days before treatment. We assessed the effect of lead time on baseline estimates, using historical data (2010-14) from a sea lice data management programme (Fish-iTrends). Data were aggregated at the cage level for three life stages: (i) chalimus, (ii) pre-adult and adult male and (iii) adult female. Sea lice counts were log-transformed, and mean counts by lead time relative to treatment day were computed and compared separately for each life stage, using linear mixed models. There were 1,658 observations (treatment events) from 56 sites in 5 Bay Management Areas. Our study showed that lead time had a significant effect on the estimated sea lice abundance, which was moderated by season. During the late summer and autumn periods, counting on the day of treatment gave significantly higher values than other days and would be a more appropriate baseline estimate, while during spring and early summer abundance estimates were comparable among counts within 5 days of treatment. A season-based lead time window may be most appropriate when estimating baseline sea lice levels. © 2016 John Wiley & Sons Ltd.

  15. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  16. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  17. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  18. Regression Models For Multivariate Count Data.

    Science.gov (United States)

    Zhang, Yiwen; Zhou, Hua; Zhou, Jin; Sun, Wei

    2017-01-01

    Data with multivariate count responses frequently occur in modern applications. The commonly used multinomial-logit model is limiting due to its restrictive mean-variance structure. For instance, analyzing count data from the recent RNA-seq technology by the multinomial-logit model leads to serious errors in hypothesis testing. The ubiquity of over-dispersion and complicated correlation structures among multivariate counts calls for more flexible regression models. In this article, we study some generalized linear models that incorporate various correlation structures among the counts. Current literature lacks a treatment of these models, partly due to the fact that they do not belong to the natural exponential family. We study the estimation, testing, and variable selection for these models in a unifying framework. The regression models are compared on both synthetic and real RNA-seq data.

  19. Validity of total leucocytes count and neutrophil count (differential leucocytes) in diagnosing suspected acute appendicitis

    International Nuclear Information System (INIS)

    Anwar, M.W.; Abid, I.

    2012-01-01

    Objective: To compare the diagnostic accuracy of Total Leucocytes Count (TLC) with Neutrophil count; Differential Leucocytes Count (DLC) in diagnosing cases of suspected acute appendicitis. Study design: Validation study. Place and duration of the study: Department of Surgery, Combined Military Hospital (CMH) Rawalpindi, from April 2008 to October 2008. Method: A total of 100 patients of Pain right iliac fossae who underwent appendicectomy were included. Detailed history of all the patients was taken for pain in right lower abdomen, its severity, its nature, relieving or provoking factors. Clinical examination was done in detail. Total and Differential Leucocytes Count was done. Every patient's appendix was examined grossly after appendicectomy for evidence of appendicitis. Diagnostic measures of TLC and DLC were calculated by standard formulas. Results: Sensitivity and specificity of TLC is 86.9% and 81.25% respectively and that of DLC is 82% and 68.75% respectively. Accuracy was 86% for TLC and 80% for DLC. Conclusion: TLC is more sensitive, specific and accurate test as compared to DLC and it should be used as diagnostic aid for suspected acute appendicitis cases. (author)

  20. Overestimating fish counts by non-instantaneous visual censuses: consequences for population and community descriptions.

    Directory of Open Access Journals (Sweden)

    Christine Ward-Paige

    Full Text Available BACKGROUND: Increasingly, underwater visual censuses (UVC are used to assess fish populations. Several studies have demonstrated the effectiveness of protected areas for increasing fish abundance or provided insight into the natural abundance and structure of reef fish communities in remote areas. Recently, high apex predator densities (>100,000 individuals x km(-2 and biomasses (>4 tonnes x ha(-1 have been reported for some remote islands suggesting the occurrence of inverted trophic biomass pyramids. However, few studies have critically evaluated the methods used for sampling conspicuous and highly mobile fish such as sharks. Ideally, UVC are done instantaneously, however, researchers often count animals that enter the survey area after the survey has started, thus performing non-instantaneous UVC. METHODOLOGY/PRINCIPAL FINDINGS: We developed a simulation model to evaluate counts obtained by divers deploying non-instantaneous belt-transect and stationary-point-count techniques. We assessed how fish speed and survey procedure (visibility, diver speed, survey time and dimensions affect observed fish counts. Results indicate that the bias caused by fish speed alone is huge, while survey procedures had varying effects. Because the fastest fishes tend to be the largest, the bias would have significant implications on their biomass contribution. Therefore, caution is needed when describing abundance, biomass, and community structure based on non-instantaneous UVC, especially for highly mobile species such as sharks. CONCLUSIONS/SIGNIFICANCE: Based on our results, we urge that published literature state explicitly whether instantaneous counts were made and that survey procedures be accounted for when non-instantaneous counts are used. Using published density and biomass values of communities that include sharks we explore the effect of this bias and suggest that further investigation may be needed to determine pristine shark abundances and the

  1. Dual resolution cone beam breast CT: A feasibility study

    International Nuclear Information System (INIS)

    Chen Lingyun; Shen Youtao; Lai, Chao-Jen; Han Tao; Zhong Yuncheng; Ge Shuaiping; Liu Xinming; Wang Tianpeng; Yang, Wei T.; Whitman, Gary J.; Shaw, Chris C.

    2009-01-01

    Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 μm and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

  2. Enhanced counting efficiency of Cerenkov radiation from bismuth-210

    International Nuclear Information System (INIS)

    Peck, G.A.; Smith, J.D.

    1998-01-01

    This paper describes the measurement of 210 Bi by Cerenkov counting in a commercial liquid scintillation counter. The counting efficiency in water is 0.17 counts per second per Becquerel (17%). When the enhancers Triton X-100 (15% v/v) and sodium salicylate (1% m/v) are added to the solution the counting efficiency for 210 Bi increases from 17% to 75%. The 210 Po daughter of 210 Bi causes interference of 0.85 counts per second per Becquerel in the presence of the enhancers but not in water. When 210 Bi and 210 Po are present in secular equilibrium the total counting efficiency is 160%. When 210 Bi and 210 Po are not in secular equilibrium the 210 Po can be removed immediately before counting by plating onto silver foil. The use of the enhancers gives a substantial increase in counting efficiency compared to counting in water. Compared with solutions used in liquid scintillation counting the enhancer solution is inexpensive and can be disposed of without environmental hazard. (author)

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  4. Design and development of multiple sample counting setup

    International Nuclear Information System (INIS)

    Rath, D.P.; Murali, S.; Babu, D.A.R.

    2010-01-01

    Full text: The analysis of active samples on regular basis for ambient air activity and floor contamination from radio chemical lab accounts for major chunk of the operational activity in Health Physicist's responsibility. The requirement for daily air sample analysis on immediate counting and delayed counting from various labs in addition to samples of smear swipe check of lab led to the urge for development of system that could cater multiple sample analysis in a time programmed manner on a single sample loading. A multiple alpha/beta counting system for counting was designed and fabricated. It has arrangements for loading 10 samples in slots in order, get counted in a time programmed manner with results displayed and records maintained in PC. The paper describes the design and development of multiple sample counting setup presently in use at the facility has resulted in reduction of man-hour consumption in counting and recording of the results

  5. Automated vehicle counting using image processing and machine learning

    Science.gov (United States)

    Meany, Sean; Eskew, Edward; Martinez-Castro, Rosana; Jang, Shinae

    2017-04-01

    Vehicle counting is used by the government to improve roadways and the flow of traffic, and by private businesses for purposes such as determining the value of locating a new store in an area. A vehicle count can be performed manually or automatically. Manual counting requires an individual to be on-site and tally the traffic electronically or by hand. However, this can lead to miscounts due to factors such as human error A common form of automatic counting involves pneumatic tubes, but pneumatic tubes disrupt traffic during installation and removal, and can be damaged by passing vehicles. Vehicle counting can also be performed via the use of a camera at the count site recording video of the traffic, with counting being performed manually post-recording or using automatic algorithms. This paper presents a low-cost procedure to perform automatic vehicle counting using remote video cameras with an automatic counting algorithm. The procedure would utilize a Raspberry Pi micro-computer to detect when a car is in a lane, and generate an accurate count of vehicle movements. The method utilized in this paper would use background subtraction to process the images and a machine learning algorithm to provide the count. This method avoids fatigue issues that are encountered in manual video counting and prevents the disruption of roadways that occurs when installing pneumatic tubes

  6. Evaluation of software tools for automated identification of neuroanatomical structures in quantitative β-amyloid PET imaging to diagnose Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Tuszynski, Tobias; Luthardt, Julia; Butzke, Daniel; Tiepolt, Solveig; Seese, Anita; Barthel, Henryk [Leipzig University Medical Centre, Department of Nuclear Medicine, Leipzig (Germany); Rullmann, Michael; Hesse, Swen; Sabri, Osama [Leipzig University Medical Centre, Department of Nuclear Medicine, Leipzig (Germany); Leipzig University Medical Centre, Integrated Treatment and Research Centre (IFB) Adiposity Diseases, Leipzig (Germany); Gertz, Hermann-Josef [Leipzig University Medical Centre, Department of Psychiatry, Leipzig (Germany); Lobsien, Donald [Leipzig University Medical Centre, Department of Neuroradiology, Leipzig (Germany)

    2016-06-15

    For regional quantification of nuclear brain imaging data, defining volumes of interest (VOIs) by hand is still the gold standard. As this procedure is time-consuming and operator-dependent, a variety of software tools for automated identification of neuroanatomical structures were developed. As the quality and performance of those tools are poorly investigated so far in analyzing amyloid PET data, we compared in this project four algorithms for automated VOI definition (HERMES Brass, two PMOD approaches, and FreeSurfer) against the conventional method. We systematically analyzed florbetaben brain PET and MRI data of ten patients with probable Alzheimer's dementia (AD) and ten age-matched healthy controls (HCs) collected in a previous clinical study. VOIs were manually defined on the data as well as through the four automated workflows. Standardized uptake value ratios (SUVRs) with the cerebellar cortex as a reference region were obtained for each VOI. SUVR comparisons between ADs and HCs were carried out using Mann-Whitney-U tests, and effect sizes (Cohen's d) were calculated. SUVRs of automatically generated VOIs were correlated with SUVRs of conventionally derived VOIs (Pearson's tests). The composite neocortex SUVRs obtained by manually defined VOIs were significantly higher for ADs vs. HCs (p=0.010, d=1.53). This was also the case for the four tested automated approaches which achieved effect sizes of d=1.38 to d=1.62. SUVRs of automatically generated VOIs correlated significantly with those of the hand-drawn VOIs in a number of brain regions, with regional differences in the degree of these correlations. Best overall correlation was observed in the lateral temporal VOI for all tested software tools (r=0.82 to r=0.95, p<0.001). Automated VOI definition by the software tools tested has a great potential to substitute for the current standard procedure to manually define VOIs in β-amyloid PET data analysis. (orig.)

  7. Calculating concentration of inhaled radiolabeled particles from external gamma counting: External counting efficiency and attenuation coefficient of thorax

    International Nuclear Information System (INIS)

    Langenback, E.G.; Foster, W.M.; Bergofsky, E.H.

    1989-01-01

    We determined the overall external counting efficiency of radiolabeled particles deposited in the sheep lung. This efficiency permits the noninvasive calculation of the number of particles and microcuries from gamma-scintillation lung images of the live sheep. Additionally, we have calculated the attenuation of gamma radiation (120 keV) by the posterior chest wall and the gamma-scintillation camera collection efficiency of radiation emitted from the lung. Four methods were employed in our experiments: (1) by light microscopic counting of discrete carbonized polystyrene particles with a count median diameter (CMD) of 2.85 microns and tagged with cobalt-57, we delineated a linear relationship between the number of particles and the emitted counts per minute (cpm) detected by well scintillation counting; (2) from this conversion relationship we determined the number of particles inhaled and deposited in the lungs by scintillation counting fragments of dissected lung at autopsy; (3) we defined a linear association between the number of particles or microcuries contained in the lung and the emitted radiation as cpm detected by a gamma scintillation camera in the live sheep prior to autopsy; and (4) we compared the emitted radiation from the lungs of the live sheep to that of whole excised lungs in order to calculate the attenuation coefficient (ac) of the chest wall. The mean external counting efficiency was 4.00 X 10(4) particles/cpm (5.1 X 10(-3) microCi/cpm), the camera collection efficiency was 1 cpm/10(4) disintegrations per minute (dpm), and the ac had a mean of 0.178/cm. The external counting efficiency remained relatively constant over a range of particles and microcuries, permitting a more general use of this ratio to estimate number of particles or microcuries depositing after inhalation in a large mammalian lung if a similarly collimated gamma camera system is used

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  10. Comparison of visual-based helicopter and fixed-wing forward-looking infrared surveys for counting white-tailed deer Odocoileus virginianus

    Science.gov (United States)

    Storm, Daniel J.; Samuel, Michael D.; Van Deelen, Timothy R.; Malcolm, Karl D.; Rolley, Robert E.; Frost, Nancy A.; Bates, Donald P.; Richards, Bryan J.

    2011-01-01

    Aerial surveys using direct counts of animals are commonly used to estimate deer abundance. Forward-looking infrared (FLIR) technology is increasingly replacing traditional methods such as visual observation from helicopters. Our goals were to compare fixed-wing FLIR and visual, helicopter-based counts in terms of relative bias, influence of snow cover and cost. We surveyed five plots: four 41.4 km2 plots with free-ranging white-tailed deer Odocoileus virginianus populations in Wisconsin and a 5.3 km2 plot with a white-tailed deer population contained by a high fence in Michigan. We surveyed plots using both fixed-wing FLIR and helicopters, both with snow cover and without snow. None of the methods counted more deer than the other when snow was present. Helicopter counts were lower in the absence of snow, but lack of snow cover did not apparently affect FLIR. Group sizes of observed deer were similar regardless of survey method or season. We found that FLIR counts were generally precise (CV = 0.089) when two or three replicate surveys were conducted within a few hours. However, at the plot level, FLIR counts differed greatly between seasons, suggesting that detection rates vary over larger time scales. Fixed-wing FLIR was more costly than visual observers in helicopters and was more restrictive in terms of acceptable survey conditions. Further research is needed to understand what factors influence the detection of deer during FLIR surveys.

  11. Algorithm for counting large directed loops

    Energy Technology Data Exchange (ETDEWEB)

    Bianconi, Ginestra [Abdus Salam International Center for Theoretical Physics, Strada Costiera 11, 34014 Trieste (Italy); Gulbahce, Natali [Theoretical Division and Center for Nonlinear Studies, Los Alamos National Laboratory, NM 87545 (United States)

    2008-06-06

    We derive a Belief-Propagation algorithm for counting large loops in a directed network. We evaluate the distribution of the number of small loops in a directed random network with given degree sequence. We apply the algorithm to a few characteristic directed networks of various network sizes and loop structures and compare the algorithm with exhaustive counting results when possible. The algorithm is adequate in estimating loop counts for large directed networks and can be used to compare the loop structure of directed networks and their randomized counterparts.

  12. Logistic regression for dichotomized counts.

    Science.gov (United States)

    Preisser, John S; Das, Kalyan; Benecha, Habtamu; Stamm, John W

    2016-12-01

    Sometimes there is interest in a dichotomized outcome indicating whether a count variable is positive or zero. Under this scenario, the application of ordinary logistic regression may result in efficiency loss, which is quantifiable under an assumed model for the counts. In such situations, a shared-parameter hurdle model is investigated for more efficient estimation of regression parameters relating to overall effects of covariates on the dichotomous outcome, while handling count data with many zeroes. One model part provides a logistic regression containing marginal log odds ratio effects of primary interest, while an ancillary model part describes the mean count of a Poisson or negative binomial process in terms of nuisance regression parameters. Asymptotic efficiency of the logistic model parameter estimators of the two-part models is evaluated with respect to ordinary logistic regression. Simulations are used to assess the properties of the models with respect to power and Type I error, the latter investigated under both misspecified and correctly specified models. The methods are applied to data from a randomized clinical trial of three toothpaste formulations to prevent incident dental caries in a large population of Scottish schoolchildren. © The Author(s) 2014.

  13. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  14. Multiple-Event, Single-Photon Counting Imaging Sensor

    Science.gov (United States)

    Zheng, Xinyu; Cunningham, Thomas J.; Sun, Chao; Wang, Kang L.

    2011-01-01

    The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

  15. Criterion-Validity of Commercially Available Physical Activity Tracker to Estimate Step Count, Covered Distance and Energy Expenditure during Sports Conditions

    Directory of Open Access Journals (Sweden)

    Yvonne Wahl

    2017-09-01

    Full Text Available Background: In the past years, there was an increasing development of physical activity tracker (Wearables. For recreational people, testing of these devices under walking or light jogging conditions might be sufficient. For (elite athletes, however, scientific trustworthiness needs to be given for a broad spectrum of velocities or even fast changes in velocities reflecting the demands of the sport. Therefore, the aim was to evaluate the validity of eleven Wearables for monitoring step count, covered distance and energy expenditure (EE under laboratory conditions with different constant and varying velocities.Methods: Twenty healthy sport students (10 men, 10 women performed a running protocol consisting of four 5 min stages of different constant velocities (4.3; 7.2; 10.1; 13.0 km·h−1, a 5 min period of intermittent velocity, and a 2.4 km outdoor run (10.1 km·h−1 while wearing eleven different Wearables (Bodymedia Sensewear, Beurer AS 80, Polar Loop, Garmin Vivofit, Garmin Vivosmart, Garmin Vivoactive, Garmin Forerunner 920XT, Fitbit Charge, Fitbit Charge HR, Xaomi MiBand, Withings Pulse Ox. Step count, covered distance, and EE were evaluated by comparing each Wearable with a criterion method (Optogait system and manual counting for step count, treadmill for covered distance and indirect calorimetry for EE.Results: All Wearables, except Bodymedia Sensewear, Polar Loop, and Beurer AS80, revealed good validity (small MAPE, good ICC for all constant and varying velocities for monitoring step count. For covered distance, all Wearables showed a very low ICC (<0.1 and high MAPE (up to 50%, revealing no good validity. The measurement of EE was acceptable for the Garmin, Fitbit and Withings Wearables (small to moderate MAPE, while Bodymedia Sensewear, Polar Loop, and Beurer AS80 showed a high MAPE up to 56% for all test conditions.Conclusion: In our study, most Wearables provide an acceptable level of validity for step counts at different

  16. Lazy reference counting for the Microgrid

    NARCIS (Netherlands)

    Poss, R.; Grelck, C.; Herhut, S.; Scholz, S.-B.

    2012-01-01

    This papers revisits non-deferred reference counting, a common technique to ensure that potentially shared large heap objects can be reused safely when they are both input and output to computations. Traditionally, thread-safe reference counting exploit implicit memory-based communication of counter

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  18. Preverbal and verbal counting and computation.

    Science.gov (United States)

    Gallistel, C R; Gelman, R

    1992-08-01

    We describe the preverbal system of counting and arithmetic reasoning revealed by experiments on numerical representations in animals. In this system, numerosities are represented by magnitudes, which are rapidly but inaccurately generated by the Meck and Church (1983) preverbal counting mechanism. We suggest the following. (1) The preverbal counting mechanism is the source of the implicit principles that guide the acquisition of verbal counting. (2) The preverbal system of arithmetic computation provides the framework for the assimilation of the verbal system. (3) Learning to count involves, in part, learning a mapping from the preverbal numerical magnitudes to the verbal and written number symbols and the inverse mappings from these symbols to the preverbal magnitudes. (4) Subitizing is the use of the preverbal counting process and the mapping from the resulting magnitudes to number words in order to generate rapidly the number words for small numerosities. (5) The retrieval of the number facts, which plays a central role in verbal computation, is mediated via the inverse mappings from verbal and written numbers to the preverbal magnitudes and the use of these magnitudes to find the appropriate cells in tabular arrangements of the answers. (6) This model of the fact retrieval process accounts for the salient features of the reaction time differences and error patterns revealed by experiments on mental arithmetic. (7) The application of verbal and written computational algorithms goes on in parallel with, and is to some extent guided by, preverbal computations, both in the child and in the adult.

  19. Determining Gate Count Reliability in a Library Setting

    OpenAIRE

    Jeffrey Phillips

    2016-01-01

    Objective – Patron counts are a common form of measurement for library assessment. To develop accurate library statistics, it is necessary to determine any differences between various counting devices. A yearlong comparison between card reader turnstiles and laser gate counters in a university library sought to offer a standard percentage of variance and provide suggestions to increase the precision of counts. Methods – The collection of library exit counts identified the differences be...

  20. A template-based procedure for determining white matter integrity in the internal capsule early after stroke

    Directory of Open Access Journals (Sweden)

    Matthew A. Petoe

    2014-01-01

    Full Text Available The integrity of descending white matter pathways, measured by fractional anisotropy from DW-MRI, is a key prognostic indicator of motor recovery after stroke. Barriers to translation of fractional anisotropy measures into routine clinical practice include the time required for manually delineating volumes of interest (VOIs, and inter-examiner variability in this process. This study investigated whether registering and then editing template volumes of interest ‘as required’ would improve inter-examiner reliability compared with manual delineation, without compromising validity. MRI was performed with 30 sub-acute stroke patients with motor deficits (mean NIHSS = 11, range 0–17. Four independent examiners manually delineated VOIs for the posterior limbs of the internal capsules on T1 images, or edited template VOIs that had been registered to the T1 images if they encroached on ventricles or basal ganglia. Fractional anisotropy within each VOI and interhemispheric asymmetry were then calculated. We found that 13/30 registered template VOIs required editing. Edited template VOIs were more spatially similar between examiners than the manually delineated VOIs (p = 0.005. Both methods produced similar asymmetry values that correlated with clinical scores with near perfect levels of agreement between examiners. Contralesional fractional anisotropy correlated with age when edited template VOIs were used but not when VOIs were manually delineated. Editing template VOIs as required is reliable, increases the validity of fractional anisotropy measurements in the posterior limb of the internal capsule, and is less time-consuming compared to manual delineation. This approach could support the use of FA asymmetry measures in routine clinical practice.

  1. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  2. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  3. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Science.gov (United States)

    Al-Marzoki, Jasim M; Al-Maaroof, Zainab W; Kadhum, Ali H

    2012-01-01

    Background The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq. Methods A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks) and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually. Results Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3) g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6) × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472) × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count. Conclusion Most results in the current study were within the reference range. The hematological reference values for Iraqi neonatal cord plasma need to be confirmed by larger numbers of blood samples and by collecting samples from

  4. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  5. Relationship between salivary flow rates and Candida albicans counts.

    Science.gov (United States)

    Navazesh, M; Wood, G J; Brightman, V J

    1995-09-01

    Seventy-one persons (48 women, 23 men; mean age, 51.76 years) were evaluated for salivary flow rates and Candida albicans counts. Each person was seen on three different occasions. Samples of unstimulated whole, chewing-stimulated whole, acid-stimulated parotid, and candy-stimulated parotid saliva were collected under standardized conditions. An oral rinse was also obtained and evaluated for Candida albicans counts. Unstimulated and chewing-stimulated whole flow rates were negatively and significantly (p Candida counts. Unstimulated whole saliva significantly (p Candida counts of 0 versus or = 500 count. Differences in stimulated parotid flow rates were not significant among different levels of Candida counts. The results of this study reveal that whole saliva is a better predictor than parotid saliva in identification of persons with high Candida albicans counts.

  6. Reticulocyte Count Test

    Science.gov (United States)

    ... htm. (2004 Summer). Immature Reticulocyte Fraction(IRF). The Pathology Center Newsletter v9(1). [On-line information]. Available ... Company, Philadelphia, PA [18th Edition]. Levin, M. (2007 March 8, Updated). Reticulocyte Count. MedlinePlus Medical Encyclopedia [On- ...

  7. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  8. CERNDxCTA counting mode chip

    International Nuclear Information System (INIS)

    Moraes, D.; Kaplon, J.; Nygard, E.

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e - , for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors

  9. Seed counting system evaluation using arduino microcontroller

    Directory of Open Access Journals (Sweden)

    Paulo Fernando Escobar Paim

    2018-01-01

    Full Text Available The development of automated systems has been highlighted in the most diverse productive sectors, among them, the agricultural sector. These systems aim to optimize activities by increasing operational efficiency and quality of work. In this sense, the present work has the objective of evaluating a prototype developed for seed count in laboratory, using Arduino microcontroller. The prototype of the system for seed counting was built using a dosing mechanism commonly used in seeders, electric motor, Arduino Uno, light dependent resistor and light emitting diode. To test the prototype, a completely randomized design (CRD was used in a two-factorial scheme composed of three groups defined according to the number of seeds (500, 1000 and 1500 seeds tested, three speeds of the dosing disc that allowed the distribution in 17, 21 and 32 seeds per second, with 40 repetitions evaluating the seed counting prototype performance in different speeds. The prototype of the bench counter showed a moderate variability of seed number of counted within the nine tests and a high precision in the seed count on the distribution speeds of 17 and 21 seeds per second (s-1 up to 1500 seeds tested. Therefore, based on the observed results, the developed prototype presents itself as an excellent tool for counting seeds in laboratory.

  10. Integrating count and detection–nondetection data to model population dynamics

    Science.gov (United States)

    Zipkin, Elise F.; Rossman, Sam; Yackulic, Charles B.; Wiens, David; Thorson, James T.; Davis, Raymond J.; Grant, Evan H. Campbell

    2017-01-01

    There is increasing need for methods that integrate multiple data types into a single analytical framework as the spatial and temporal scale of ecological research expands. Current work on this topic primarily focuses on combining capture–recapture data from marked individuals with other data types into integrated population models. Yet, studies of species distributions and trends often rely on data from unmarked individuals across broad scales where local abundance and environmental variables may vary. We present a modeling framework for integrating detection–nondetection and count data into a single analysis to estimate population dynamics, abundance, and individual detection probabilities during sampling. Our dynamic population model assumes that site-specific abundance can change over time according to survival of individuals and gains through reproduction and immigration. The observation process for each data type is modeled by assuming that every individual present at a site has an equal probability of being detected during sampling processes. We examine our modeling approach through a series of simulations illustrating the relative value of count vs. detection–nondetection data under a variety of parameter values and survey configurations. We also provide an empirical example of the model by combining long-term detection–nondetection data (1995–2014) with newly collected count data (2015–2016) from a growing population of Barred Owl (Strix varia) in the Pacific Northwest to examine the factors influencing population abundance over time. Our model provides a foundation for incorporating unmarked data within a single framework, even in cases where sampling processes yield different detection probabilities. This approach will be useful for survey design and to researchers interested in incorporating historical or citizen science data into analyses focused on understanding how demographic rates drive population abundance.

  11. Using DNA to test the utility of pellet-group counts as an index of deer counts

    Science.gov (United States)

    T. J. Brinkman; D. K. Person; W. Smith; F. Stuart Chapin; K. McCoy; M. Leonawicz; K. Hundertmark

    2013-01-01

    Despite widespread use of fecal pellet-group counts as an index of ungulate density, techniques used to convert pellet-group numbers to ungulate numbers rarely are based on counts of known individuals, seldom evaluated across spatial and temporal scales, and precision is infrequently quantified. Using DNA from fecal pellets to identify individual deer, we evaluated the...

  12. Tutorial on X-ray photon counting detector characterization.

    Science.gov (United States)

    Ren, Liqiang; Zheng, Bin; Liu, Hong

    2018-01-01

    Recent advances in photon counting detection technology have led to significant research interest in X-ray imaging. As a tutorial level review, this paper covers a wide range of aspects related to X-ray photon counting detector characterization. The tutorial begins with a detailed description of the working principle and operating modes of a pixelated X-ray photon counting detector with basic architecture and detection mechanism. Currently available methods and techniques for charactering major aspects including energy response, noise floor, energy resolution, count rate performance (detector efficiency), and charge sharing effect of photon counting detectors are comprehensively reviewed. Other characterization aspects such as point spread function (PSF), line spread function (LSF), contrast transfer function (CTF), modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), bias voltage, radiation damage, and polarization effect are also remarked. A cadmium telluride (CdTe) pixelated photon counting detector is employed for part of the characterization demonstration and the results are presented. This review can serve as a tutorial for X-ray imaging researchers and investigators to understand, operate, characterize, and optimize photon counting detectors for a variety of applications.

  13. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  14. SU-E-J-143: Short- and Near-Term Effects of Proton Therapy On Cerebral White Matter

    Energy Technology Data Exchange (ETDEWEB)

    Uh, J; Merchant, T; Ogg, R; Sabin, N; Hua, C [St. Jude Children' s Research Hospital, Memphis, TN (United States); Indelicato, D [University of Florida Proton Therapy Institute, Jacksonville, FL (United States)

    2014-06-01

    Purpose: To assess early effects of proton therapy on the structural integrity of cerebral white matter in relation to the subsequent near-term development of such effects. Methods: Sixteen children (aged 2–19 years) with craniopharyngioma underwent proton therapy of 54 Cobalt Gray Equivalent (CGE) in a prospective therapeutic trial. Diffusion tensor imaging (DTI) was performed at baseline before proton therapy and every 3 months thereafter. Tract-based spatial statics analysis of DTI data was performed to derive the fractional anisotropy (FA) and radial diffusivity (RD) in 26 volumes of interest (VOIs). The dose distributions were spatially normalized to identify VOIs prone to high doses. The longitudinal percentage changes of the FA and RD in these VOIs at 3 and 12 months from the baseline were calculated, and their relationships were evaluated. Results: The average dose was highest to the cerebral peduncle (CP), corticospinal tract (CST) in the pons, pontine crossing tract (PCT), anterior/posterior limbs of the internal capsule (ALIC/PLIC), and genu of the corpus callosum (GCC). It ranged from 33.3 GCE (GCC) to 49.7 GCE (CP). A mild but statistically significant (P<0.05) decline of FA was observed 3 months after proton therapy in all VOIs except the PLIC and ranged from −1.7% (ALIC) to −2.8% (PCT). A significant increase of RD was found in the CP (3.5%) and ALIC (2.1%). The average longitudinal change from the baseline was reduced at 12 months for most VOIs. However, the standard deviation increased, indicating that the temporal pattern varied individually. The follow-up measurements at 3 and 12 months correlated for the CP, CST, PCT, and GCC (P < 0.04). Conclusion: DTI data suggest early (3 months) effects of proton therapy on microstructures in the white matter. The subsequent follow-up indicated individual variation of the changes, which was partly implied by the early effects.

  15. Project and construction of counting system for neutron probe

    International Nuclear Information System (INIS)

    Monteiro, W.P.

    1985-01-01

    A counting system was developed for coupling neutron probe aiming to register pulses produced by slow neutron interaction in the detector. The neutron probe consists of fast neutron source, thermal neutron detector, amplifier circuit and pulse counting circuit. The counting system is composed by counting circuit, timer and signal circuit. (M.C.K.)

  16. Counts and colors of faint galaxies

    International Nuclear Information System (INIS)

    Kron, R.G.

    1980-01-01

    The color distribution of faint galaxies is an observational dimension which has not yet been fully exploited, despite the important constraints obtainable for galaxy evolution and cosmology. Number-magnitude counts alone contain very diluted information about the state of things because galaxies from a wide range in redshift contribute to the counts at each magnitude. The most-frequently-seen type of galaxy depends on the luminosity function and the relative proportions of galaxies of different spectral classes. The addition of color as a measured quantity can thus considerably sharpen the interpretation of galaxy counts since the apparent color depends on the redshift and rest-frame spectrum. (Auth.)

  17. Update on Linear Mode Photon Counting with the HgCdTe Linear Mode Avalanche Photodiode

    Science.gov (United States)

    Beck, Jeffrey D.; Kinch, Mike; Sun, Xiaoli

    2014-01-01

    The behavior of the gain-voltage characteristic of the mid-wavelength infrared cutoff HgCdTe linear mode avalanche photodiode (e-APD) is discussed both experimentally and theoretically as a function of the width of the multiplication region. Data are shown that demonstrate a strong dependence of the gain at a given bias voltage on the width of the n- gain region. Geometrical and fundamental theoretical models are examined to explain this behavior. The geometrical model takes into account the gain-dependent optical fill factor of the cylindrical APD. The theoretical model is based on the ballistic ionization model being developed for the HgCdTe APD. It is concluded that the fundamental theoretical explanation is the dominant effect. A model is developed that combines both the geometrical and fundamental effects. The model also takes into account the effect of the varying multiplication width in the low bias region of the gain-voltage curve. It is concluded that the lower than expected gain seen in the first 2 × 8 HgCdTe linear mode photon counting APD arrays, and higher excess noise factor, was very likely due to the larger than typical multiplication region length in the photon counting APD pixel design. The implications of these effects on device photon counting performance are discussed.

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  19. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Marzoki JM

    2012-10-01

    Full Text Available Jasim M Al-Marzoki1, Zainab W Al-Maaroof2, Ali H Kadhum31Department of Pediatrics, 2Department of Pathology, Babylon Medical College, 3Babylon Gynecology and Pediatric Teaching Hospital, Hilla, IraqBackground: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq.Methods: A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually.Results: Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3 g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6 × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472 × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count.Conclusion: Most results

  20. MR-based automatic delineation of volumes of interest in human brain PET images using probability maps

    DEFF Research Database (Denmark)

    Svarer, Claus; Madsen, Karina; Hasselbalch, Steen G.

    2005-01-01

    subjects' MR-images, where VOI sets have been defined manually. High-resolution structural MR-images and 5-HT(2A) receptor binding PET-images (in terms of (18)F-altanserin binding) from 10 healthy volunteers and 10 patients with mild cognitive impairment were included for the analysis. A template including...... 35 VOIs was manually delineated on the subjects' MR images. Through a warping algorithm template VOI sets defined from each individual were transferred to the other subjects MR-images and the voxel overlap was compared to the VOI set specifically drawn for that particular individual. Comparisons were...... delineation of the VOI set. The approach was also shown to work equally well in individuals with pronounced cerebral atrophy. Probability-map-based automatic delineation of VOIs is a fast, objective, reproducible, and safe way to assess regional brain values from PET or SPECT scans. In addition, the method...

  1. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  17. Development of a mobile application for manual traffic counts

    Directory of Open Access Journals (Sweden)

    Ghanim Mohammad

    2017-01-01

    Full Text Available The use of technology in performing traffic counts has become widely used by many transportation agencies and private sectors. Different technologies have been employed to perform such counts, such as inductive loops, image processing, Bluetooth technologies, and laser and infrared technologies. However, the use of these advanced technologies come with extra cost to develop, install, and maintain. While the use of advanced technologies provide reliable traffic counts and vehicle classifications data, the use of manual traffic is an inevitable task. Manual traffic counts can serve different purposes, such as performing quality control or conducting short-term traffic survey. Manual traffic counts are usually conducted with the use of the traditional paper-and-pencil approach or the use of hand-held devices that are specifically developed to assess performing manual traffic counts. In this paper, the development of a mobile app that can be used to assist those who need to perform manual traffic counts. The app can be used by many public agencies, private sectors, and college students to collect their traffic data. It also provides users with the capabilities of sharing their traffic counts instantly, where traffic counts can be extracted and processed quickly by other parties.

  18. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  19. Change-Point Methods for Overdispersed Count Data

    National Research Council Canada - National Science Library

    Wilken, Brian A

    2007-01-01

    .... Although the Poisson model is often used to model count data, the two-parameter gamma-Poisson mixture parameterization of the negative binomial distribution is often a more adequate model for overdispersed count data...

  20. Leveraging multiple datasets for deep leaf counting

    OpenAIRE

    Dobrescu, Andrei; Giuffrida, Mario Valerio; Tsaftaris, Sotirios A

    2017-01-01

    The number of leaves a plant has is one of the key traits (phenotypes) describing its development and growth. Here, we propose an automated, deep learning based approach for counting leaves in model rosette plants. While state-of-the-art results on leaf counting with deep learning methods have recently been reported, they obtain the count as a result of leaf segmentation and thus require per-leaf (instance) segmentation to train the models (a rather strong annotation). Instead, our method tre...

  1. Performance of 3DOSEM and MAP algorithms for reconstructing low count SPECT acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    Grootjans, Willem [Radboud Univ. Medical Center, Nijmegen (Netherlands). Dept. of Radiology and Nuclear Medicine; Leiden Univ. Medical Center (Netherlands). Dept. of Radiology; Meeuwis, Antoi P.W.; Gotthardt, Martin; Visser, Eric P. [Radboud Univ. Medical Center, Nijmegen (Netherlands). Dept. of Radiology and Nuclear Medicine; Slump, Cornelis H. [Univ. Twente, Enschede (Netherlands). MIRA Inst. for Biomedical Technology and Technical Medicine; Geus-Oei, Lioe-Fee de [Radboud Univ. Medical Center, Nijmegen (Netherlands). Dept. of Radiology and Nuclear Medicine; Univ. Twente, Enschede (Netherlands). MIRA Inst. for Biomedical Technology and Technical Medicine; Leiden Univ. Medical Center (Netherlands). Dept. of Radiology

    2016-07-01

    Low count single photon emission computed tomography (SPECT) is becoming more important in view of whole body SPECT and reduction of radiation dose. In this study, we investigated the performance of several 3D ordered subset expectation maximization (3DOSEM) and maximum a posteriori (MAP) algorithms for reconstructing low count SPECT images. Phantom experiments were conducted using the National Electrical Manufacturers Association (NEMA) NU2 image quality (IQ) phantom. The background compartment of the phantom was filled with varying concentrations of pertechnetate and indiumchloride, simulating various clinical imaging conditions. Images were acquired using a hybrid SPECT/CT scanner and reconstructed with 3DOSEM and MAP reconstruction algorithms implemented in Siemens Syngo MI.SPECT (Flash3D) and Hermes Hybrid Recon Oncology (Hyrid Recon 3DOSEM and MAP). Image analysis was performed by calculating the contrast recovery coefficient (CRC),percentage background variability (N%), and contrast-to-noise ratio (CNR), defined as the ratio between CRC and N%. Furthermore, image distortion is characterized by calculating the aspect ratio (AR) of ellipses fitted to the hot spheres. Additionally, the performance of these algorithms to reconstruct clinical images was investigated. Images reconstructed with 3DOSEM algorithms demonstrated superior image quality in terms of contrast and resolution recovery when compared to images reconstructed with filtered-back-projection (FBP), OSEM and 2DOSEM. However, occurrence of correlated noise patterns and image distortions significantly deteriorated the quality of 3DOSEM reconstructed images. The mean AR for the 37, 28, 22, and 17 mm spheres was 1.3, 1.3, 1.6, and 1.7 respectively. The mean N% increase in high and low count Flash3D and Hybrid Recon 3DOSEM from 5.9% and 4.0% to 11.1% and 9.0%, respectively. Similarly, the mean CNR decreased in high and low count Flash3D and Hybrid Recon 3DOSEM from 8.7 and 8.8 to 3.6 and 4

  2. Detection limits for radioanalytical counting techniques

    International Nuclear Information System (INIS)

    Hartwell, J.K.

    1975-06-01

    In low-level radioanalysis it is usually necessary to test the sample net counts against some ''Critical Level'' in order to determine if a given result indicates detection. This is an interpretive review of the work by Nicholson (1963), Currie (1968) and Gilbert (1974). Nicholson's evaluation of three different computational formulas for estimation of the ''Critical Level'' is discussed. The details of Nicholson's evaluation are presented along with a basic discussion of the testing procedures used. Recommendations are presented for calculation of confidence intervals, for reporting of analytical results, and for extension of the derived formula to more complex cases such as multiple background counts, multiple use of a single background count, and gamma spectrometric analysis

  3. Counts of low-Redshift SDSS quasar candidates

    International Nuclear Information System (INIS)

    Zeljko Ivezic

    2004-01-01

    We analyze the counts of low-redshift quasar candidates selected using nine-epoch SDSS imaging data. The co-added catalogs are more than 1 mag deeper than single-epoch SDSS data, and allow the selection of low-redshift quasar candidates using UV-excess and also variability techniques. The counts of selected candidates are robustly determined down to g = 21.5. This is about 2 magnitudes deeper than the position of a change in the slope of the counts reported by Boyle (and others) (1990, 2000) for a sample selected by UV-excess, and questioned by Hawkins and Veron (1995), who utilized a variability-selected sample. Using SDSS data, we confirm a change in the slope of the counts for both UV-excess and variability selected samples, providing strong support for the Boyle (and others) results

  4. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  5. Protecting count queries in study design.

    Science.gov (United States)

    Vinterbo, Staal A; Sarwate, Anand D; Boxwala, Aziz A

    2012-01-01

    Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems.

  6. Using Cherenkov Counting For Fast Determination of 90Sr/90Y Activity in Milk

    International Nuclear Information System (INIS)

    Tsroya, S.; Dolgin, B.; German, U.; Pelled, O.; Alfassi, Z. B.

    2014-01-01

    90Sr is one of the main long-lived fission products, and it is transferred into human body primarily by food, with milk being a substantial contributor. Due to its biochemical similarity to calcium, most strontium is efficiently incorporated into bone tissues. 90Sr is characterized by a long physical half life (28.8 y) and decays by beta particles with an Emax of 0.546 MeV to 90Y. This daughter isotope has a half life of 64 h and decays into 90Zr by beta particles with an Emax of 2.284 MeV. The milk components produce a high turbidity and light attenuation, causing a significant decrease of the counting efficiency in liquid scintillation counting (LSC) systems, mostly used for beta emitters detection. Most methods proposed in the past are time-consuming, as they are based on several stages of chemical and physical treatments, including precipitation, ashing, ion exchange and extraction (Wikins et al., 1984, Porter et al, 1961, Kimura et al., 1979). When measuring 90Sr/90Y activity by Cherenkov counting, most of the Cherenkov radiation is produced by 90Y (about 98.6%), due to the much higher energy of its beta particles relative to these from 90Sr. The counting efficiency varies strongly with color quenching, at a greater extent than in standard liquid scintillation counting (L'Annunziata, 2012), and therefore the quench correction is critical. The ‘‘external source area ratio’’ (ESAR) quench correction method was applied to measure 90Sr/90Y activities in aqueous samples with a wide range of quenching levels (Tsroya et al., 2009). This method was proved to be superior to all other quench correction methods (Tsroya et al., 2012) and is applicable also for determination of 90Sr/90Y in human urine (Tsroya et al., 2013). In the present work the applicability of the ESAR method to measurement of 90Sr/90Y activities in milk and some of its products was investigated

  7. Alaska Steller Sea Lion Pup Count Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of Steller sea lion pups on rookeries in Alaska made between 1961 and 2015. Pup counts are conducted in late June-July. Pups are...

  8. Photon counting and fluctuation of molecular movement

    International Nuclear Information System (INIS)

    Inohara, Koichi

    1978-01-01

    The direct measurement of the fluctuation of molecular motions, which provides with useful information on the molecular movement, was conducted by introducing photon counting method. The utilization of photon counting makes it possible to treat the molecular system consisting of a small number of molecules like a radioisotope in the detection of a small number of atoms, which are significant in biological systems. This method is based on counting the number of photons of the definite polarization emitted in a definite time interval from the fluorescent molecules excited by pulsed light, which are bound to the marked large molecules found in a definite spatial region. Using the probability of finding a number of molecules oriented in a definite direction in the definite spatial region, the probability of counting a number of photons in a definite time interval can be calculated. Thus the measurable count rate of photons can be related with the fluctuation of molecular movement. The measurement was carried out under the condition, in which the probability of the simultaneous arrival of more than two photons at a detector is less than 1/100. As the experimental results, the resolving power of photon-counting apparatus, the frequency distribution of the number of photons of some definite polarization counted for 1 nanosecond are shown. In the solution, the variance of the number of molecules of 500 on the average is 1200, which was estimated from the experimental data by assuming normal distribution. This departure from the Poisson distribution means that a certain correlation does exist in molecular movement. In solid solution, no significant deviation was observed. The correlation existing in molecular movement can be expressed in terms of the fluctuation of the number of molecules. (Nakai, Y.)

  9. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  10. Association between success rate and citation count of studies of radiofrequency catheter ablation for atrial fibrillation: possible evidence of citation bias.

    Science.gov (United States)

    Perino, Alexander C; Hoang, Donald D; Holmes, Tyson H; Santangeli, Pasquale; Heidenreich, Paul A; Perez, Marco V; Wang, Paul J; Turakhia, Mintu P

    2014-09-01

    The preferential citation of studies with the highest success rates could exaggerate perceived effectiveness, particularly for treatments with widely varying published success rates such as radiofrequency catheter ablation for atrial fibrillation. We systematically identified observational studies and clinical trials of radiofrequency catheter ablation of atrial fibrillation between 1990 and 2012. Generalized Poisson regression was used to estimate association between study success rate and total citation count, adjusting for sample size, journal impact factor, time since publication, study design, and whether first or last author was a consensus-defined pre-eminent expert. We identified 174 articles meeting our inclusion criteria (36 289 subjects). After adjustment only for time since publication, a 10-point increase above the mean in pooled reported success rates was associated with a 17.8% increase in citation count at 5 years postpublication (95% confidence interval, 7.1-28.4%; Pcitation count; 95% confidence interval, 7.6-29.6%; Pcitation count, which may indicate citation bias. To readers of the literature, radiofrequency catheter ablation of atrial fibrillation could be perceived to be more effective than the data supports. These findings may have implications for a wide variety of novel cardiovascular therapies. © 2014 American Heart Association, Inc.

  11. Individual patient dosimetry using quantitative SPECT imaging

    International Nuclear Information System (INIS)

    Gonzalez, J.; Oliva, J.; Baum, R.; Fisher, S.

    2002-01-01

    An approach is described to provide individual patient dosimetry for routine clinical use. Accurate quantitative SPECT imaging was achieved using appropriate methods. The volume of interest (VOI) was defined semi-automatically using a fixed threshold value obtained from phantom studies. The calibration factor to convert the voxel counts from SPECT images into activity values was determine from calibrated point source using the same threshold value as in phantom studies. From selected radionuclide the dose within and outside a sphere of voxel dimension at different distances was computed through dose point-kernels to obtain a discrete absorbed dose kernel representation around the volume source with uniform activity distribution. The spatial activity distribution from SPECT imaging was convolved with this kernel representation using the discrete Fourier transform method to yield three-dimensional absorbed dose rate distribution. The accuracy of dose rates calculation was validated by software phantoms. The absorbed dose was determined by integration of the dose rate distribution for each volume of interest (VOI). Parameters for treatment optimization such as dose rate volume histograms and dose rate statistic are provided. A patient example was used to illustrate our dosimetric calculations

  12. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  13. Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector

    Science.gov (United States)

    Jorgensen, Steven M.; Vercnocke, Andrew J.; Rundle, David S.; Butler, Philip H.; McCollough, Cynthia H.; Ritman, Erik L.

    2016-10-01

    We assessed the performance of a cadmium zinc telluride (CZT)-based Medipix3RX x-ray detector as a candidate for micro-computed tomography (micro-CT) imaging. This technology was developed at CERN for the Large Hadron Collider. It features an array of 128 by 128, 110 micrometer square pixels, each with eight simultaneous threshold counters, five of which utilize real-time charge summing, significantly reducing the charge sharing between contiguous pixels. Pixel response curves were created by imaging a range of x-ray intensities by varying x-ray tube current and by varying the exposure time with fixed x-ray current. Photon energy-related assessments were made by flooding the detector with the tin foil filtered emission of an I-125 radioisotope brachytherapy seed and sweeping the energy threshold of each of the four charge-summed counters of each pixel in 1 keV steps. Long term stability assessments were made by repeating exposures over the course of one hour. The high properly-functioning pixel yield (99%), long term stability (linear regression of whole-chip response over one hour of acquisitions: y = -0.0038x + 2284; standard deviation: 3.7 counts) and energy resolution (2.5 keV FWHM (single pixel), 3.7 keV FWHM across the full image) make this device suitable for spectral micro-CT. The charge summing performance effectively reduced the measurement corruption caused by charge sharing which, when unaccounted for, shifts the photon energy assignment to lower energies, degrading both count and energy accuracy. Effective charge summing greatly improves the potential for calibrated, energy-specific material decomposition and K edge difference imaging approaches.

  14. Evaluation of misplaced event count rate using a scintillation camera

    International Nuclear Information System (INIS)

    Yanagimoto, Shin-ichi; Tomomitsu, Tatsushi; Muranaka, Akira

    1985-01-01

    Misplaced event count rates were evaluated using an acryl scatter body of various thickness and a gamma camera. The count rate in the region of interest (ROI) within the camera view field, which was thought to represent part of the misplaced event count rate, increased as the thickness of the scatter body was increased to 5 cm, followed by a steep decline in the count rate. On the other hand, the ratio of the count rate in the ROI to the total count rate continuously increased as the thickness of the scatter body was increased. As the thickness of the scatter body was increased, the count rates increased, and the increments of increase were greater in the lower energy region of the photopeak than in the higher energy region. In ranges energy other than the photopeak, the influence of the scatter body on the count rate in the ROI was the greatest at 76 keV, which was the lowest energy we examined. (author)

  15. Counting Knights and Knaves

    Science.gov (United States)

    Levin,Oscar; Roberts, Gerri M.

    2013-01-01

    To understand better some of the classic knights and knaves puzzles, we count them. Doing so reveals a surprising connection between puzzles and solutions, and highlights some beautiful combinatorial identities.

  16. Determining Gate Count Reliability in a Library Setting

    Directory of Open Access Journals (Sweden)

    Jeffrey Phillips

    2016-09-01

    Full Text Available Objective – Patron counts are a common form of measurement for library assessment. To develop accurate library statistics, it is necessary to determine any differences between various counting devices. A yearlong comparison between card reader turnstiles and laser gate counters in a university library sought to offer a standard percentage of variance and provide suggestions to increase the precision of counts. Methods – The collection of library exit counts identified the differences between turnstile and laser gate counter data. Statistical software helped to eliminate any inaccuracies in the collection of turnstile data, allowing this data set to be the base for comparison. Collection intervals were randomly determined and demonstrated periods of slow, average, and heavy traffic. Results – After analyzing 1,039,766 patron visits throughout a year, the final totals only showed a difference of .43% (.0043 between the two devices. The majority of collection periods did not exceed a difference of 3% between the counting instruments. Conclusion – Turnstiles card readers and laser gate counters provide similar levels of reliability when measuring patron activity. Each system has potential counting inaccuracies, but several methods exist to create more precise totals. Turnstile card readers are capable of offering greater detail involving patron identity, but their high cost makes them inaccessible for libraries with lower budgets. This makes laser gate counters an affordable alternative for reliable patron counting in an academic library.

  17. Genome Replikin Count Predicts Increased Infectivity/Lethality of Viruses

    OpenAIRE

    Samuel Bogoch; Elenore S. Bogoch

    2012-01-01

    The genomes of all groups of viruses whose sequences are listed on Pubmed, specimens since 1918, analyzed by a software from Bioradar UK Ltd., contain Replikins which range in concentration from a Replikin Count (number of Replikins per 100 amino acids) of less than 1 to 30 (see accompanying communications for higher Counts in tuberculosis, malaria, and cancer, associated with higher lethality). Counts of less than 4.0 were found in ‘resting’ virus states; Counts greater than 4....

  18. [Full blood count reference values in children of 8 to 12 years old residing at 2,760 m above sea level].

    Science.gov (United States)

    Armando García-Miranda, L; Contreras, I; Estrada, J A

    2014-04-01

    To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  19. Effects of plutonium redistribution on lung counting

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1976-01-01

    Early counts of Pu deposition in lungs will tend to overestimate lung contents since calibrations are performed with a uniform distribution and since a more favorable geometry exists in contaminated subjects because the activity is closer to the periphery of the lungs. Although the concentration into the outer regions of the lungs continues as evidenced by the autopsy studies, the counts performed by L X-rays will probably underestimate the lung content; because, simplistically, the geometry several years after exposure consists of a spherical shell with a point of activity in the center. This point of activity represents concentration in the lymph nodes from which the 60 keV gamma of 241 Am will be counted, but from which few of the L X-rays will be counted (this is an example of interorgan distribution). When a correction is made to the L X-ray intensity, the lymph node contribution will tend to increase the amount subtracted while correcting for 241 Am X-rays. It is doubtful that the relative increase in X-ray intensity by concentration in the pleural and sub-pleural regions will compensate for this effect. This will make the plutonium burden disappear while the 241 Am can still be detected. This effect has been observed in a case where counts with an intraesophageal probe indicated a substantial lymph node burden. In order to improve the accuracy of in vivo plutonium measurements, an improved understanding of pulmonary distribution and of distribution effects on in vivo counting are required

  20. Use of pliable bags in liquid scintillation counting

    International Nuclear Information System (INIS)

    Simonnet, G.; Jacquet, M.A.; Sharif, A.; Engler, R.

    1981-01-01

    Pliable plastic bags have been used to replace glass or plastic vials for liquid scintillation counting. The two major advantages of this method are the lower cost of the plastic bags and the fact that, per sample, the radioactive waste is significantly reduced. The following parameters have been checked: the impermeability of the bags to various scintillator mixtures and the fact that neither the irregular shape of the bags nor their position in the counting chamber had any effect on the results of the counting. The latter was also constant with time, at least over a period of 10 days. The technique has been used to count the radioactivity of 3 H-DNA precipitates prepared from bacteria and lymphocytes and deposited on filters impregnated with only 200 μl scintillator. It is a method that can be applied to the counting of any samples deposited on filters and insoluble in scintillator. (author)

  1. System and method of liquid scintillation counting

    International Nuclear Information System (INIS)

    Rapkin, E.

    1977-01-01

    A method of liquid scintillation counting utilizing a combustion step to overcome quenching effects comprises novel features of automatic sequential introduction of samples into a combustion zone and automatic sequential collection and delivery of combustion products into a counting zone. 37 claims, 13 figures

  2. BMI in relation to sperm count

    DEFF Research Database (Denmark)

    Sermondade, N; Faure, C; Fezeu, L

    2013-01-01

    BACKGROUND The global obesity epidemic has paralleled a decrease in semen quality. Yet, the association between obesity and sperm parameters remains controversial. The purpose of this report was to update the evidence on the association between BMI and sperm count through a systematic review...... with meta-analysis. METHODS A systematic review of available literature (with no language restriction) was performed to investigate the impact of BMI on sperm count. Relevant studies published until June 2012 were identified from a Pubmed and EMBASE search. We also included unpublished data (n = 717 men...... studies were included in the meta-analysis, resulting in a sample of 13 077 men from the general population and attending fertility clinics. Data were stratified according to the total sperm count as normozoospermia, oligozoospermia and azoospermia. Standardized weighted mean differences in sperm...

  3. Combined 18F-Fluciclovine PET/MRI Shows Potential for Detection and Characterization of High-Risk Prostate Cancer.

    Science.gov (United States)

    Elschot, Mattijs; Selnæs, Kirsten M; Sandsmark, Elise; Krüger-Stokke, Brage; Størkersen, Øystein; Giskeødegård, Guro F; Tessem, May-Britt; Moestue, Siver A; Bertilsson, Helena; Bathen, Tone F

    2018-05-01

    The objective of this study was to investigate whether quantitative imaging features derived from combined 18 F-fluciclovine PET/multiparametric MRI show potential for detection and characterization of primary prostate cancer. Methods: Twenty-eight patients diagnosed with high-risk prostate cancer underwent simultaneous 18 F-fluciclovine PET/MRI before radical prostatectomy. Volumes of interest (VOIs) for prostate tumors, benign prostatic hyperplasia (BPH) nodules, prostatitis, and healthy tissue were delineated on T2-weighted images, using histology as a reference. Tumor VOIs were marked as high-grade (≥Gleason grade group 3) or not. MRI and PET features were extracted on the voxel and VOI levels. Partial least-squared discriminant analysis (PLS-DA) with double leave-one-patient-out cross-validation was performed to distinguish tumors from benign tissue (BPH, prostatitis, or healthy tissue) and high-grade tumors from other tissue (low-grade tumors or benign tissue). The performance levels of PET, MRI, and combined PET/MRI features were compared using the area under the receiver-operating-characteristic curve (AUC). Results: Voxel and VOI features were extracted from 40 tumor VOIs (26 high-grade), 36 BPH VOIs, 6 prostatitis VOIs, and 37 healthy-tissue VOIs. PET/MRI performed better than MRI and PET alone for distinguishing tumors from benign tissue (AUCs of 87%, 81%, and 83%, respectively, at the voxel level and 96%, 93%, and 93%, respectively, at the VOI level) and high-grade tumors from other tissue (AUCs of 85%, 79%, and 81%, respectively, at the voxel level and 93%, 93%, and 91%, respectively, at the VOI level). T2-weighted MRI, diffusion-weighted MRI, and PET features were the most important for classification. Conclusion: Combined 18 F-fluciclovine PET/multiparametric MRI shows potential for improving detection and characterization of high-risk prostate cancer, in comparison to MRI and PET alone. © 2018 by the Society of Nuclear Medicine and Molecular

  4. TU-E-BRA-11: Volume of Interest Cone Beam CT with a Low-Z Linear Accelerator Target: Proof-of-Concept.

    Science.gov (United States)

    Robar, J; Parsons, D; Berman, A; MacDonald, A

    2012-06-01

    This study demonstrates feasibility and advantages of volume of interest (VOI) cone beam CT (CBCT) imaging performed with an x-ray beam generated from 2.35 MeV electrons incident on a carbon linear accelerator target. The electron beam energy was reduced to 2.35 MeV in a Varian 21EX linear accelerator containing a 7.6 mm thick carbon x-ray target. Arbitrary imaging volumes were defined in the planning system to produce dynamic MLC sequences capable of tracking off-axis VOIs in phantoms. To reduce truncation artefacts, missing data in projection images were completed using a priori DRR information from the planning CT set. The feasibility of the approach was shown through imaging of an anthropomorphic phantom and the head-and-neck section of a lamb. TLD800 and EBT2 radiochromic film measurements were used to compare the VOI dose distributions with those for full-field techniques. CNR was measured for VOIs ranging from 4 to 15 cm diameter. The 2.35 MV/Carbon beam provides favorable CNR characteristics, although marked boundary and cupping artefacts arise due to truncation of projection data. These artefacts are largely eliminated using the DRR filling technique. Imaging dose was reduced by 5-10% and 75% inside and outside of the VOI, respectively, compared to full-field imaging for a cranial VOI. For the 2.35 MV/Carbon beam, CNR was shown to be approximately invariant with VOI dimension for bone and lung objects. This indicates that the advantage of the VOI approach with the low-Z target beam is substantial imaging dose reduction, not improvement of image quality. VOI CBCT using a 2.35 MV/Carbon beam is a feasible technique whereby a chosen imaging volume can be defined in the planning system and tracked during acquisition. The novel x-ray beam affords good CNR characteristics while imaging dose is localized to the chosen VOI. Funding for this project has been received from Varian Medical, Incorporated. © 2012 American Association of Physicists in Medicine.

  5. Analysis of General Power Counting Rules in Effective Field Theory

    CERN Document Server

    Gavela, B M; Manohar, A V; Merlo, L

    2016-01-01

    We derive the general counting rules for a quantum effective field theory (EFT) in $\\mathsf{d}$ dimensions. The rules are valid for strongly and weakly coupled theories, and predict that all kinetic energy terms are canonically normalized. They determine the energy dependence of scattering cross sections in the range of validity of the EFT expansion. The size of cross sections is controlled by the $\\Lambda$ power counting of EFT, not by chiral counting, even for chiral perturbation theory ($\\chi$PT). The relation between $\\Lambda$ and $f$ is generalized to $\\mathsf{d}$ dimensions. We show that the naive dimensional analysis $4\\pi$ counting is related to $\\hbar$ counting. The EFT counting rules are applied to $\\chi$PT, to Standard Model EFT and to the non-trivial case of Higgs EFT, which combines the $\\Lambda$ and chiral counting rules within a single theory.

  6. Spectrometry with high count rate for the study of the soft X-rays. Application for the plasma of WEGA

    International Nuclear Information System (INIS)

    Brouquet, P.

    1979-04-01

    The plasma of the WEGA torus, whose electron temperature varies between 0.5 and 1 keV, emits electromagnetic radiation extending to wavelengths of the order of 1A. Different improvements performed on a semi-conductor spectrometer have permitted the study of this emission in the soft X ray region (1 keV - 30 keV) at a count rate of 3.10 5 counts/s with an energy resolution of 350 eV. For each plasma shot, this diagnostic gives 4 measurements of the plasma electron temperature and of the effective charge, Zeff, with a time resolution of 5 ms. The values of the electron temperature and of the effective charge derived from the study of soft X rays are in agreement with those given by other diagnostic methods [fr

  7. Exploring the effects of transfers and readmissions on trends in population counts of hospital admissions for coronary heart disease: a Western Australian data linkage study.

    Science.gov (United States)

    Lopez, Derrick; Nedkoff, Lee; Knuiman, Matthew; Hobbs, Michael S T; Briffa, Thomas G; Preen, David B; Hung, Joseph; Beilby, John; Mathur, Sushma; Reynolds, Anna; Sanfilippo, Frank M

    2017-11-17

    To develop a method for categorising coronary heart disease (CHD) subtype in linked data accounting for different CHD diagnoses across records, and to compare hospital admission numbers and ratios of unlinked versus linked data for each CHD subtype over time, and across age groups and sex. Cohort study. Person-linked hospital administrative data covering all admissions for CHD in Western Australia from 1988 to 2013. Ratios of (1) unlinked admission counts to contiguous admission (CA) counts (accounting for transfers), and (2) 28-day episode counts (accounting for transfers and readmissions) to CA counts stratified by CHD subtype, sex and age group. In all CHD subtypes, the ratios changed in a linear or quadratic fashion over time and the coefficients of the trend term differed across CHD subtypes. Furthermore, for many CHD subtypes the ratios also differed by age group and sex. For example, in women aged 35-54 years, the ratio of unlinked to CA counts for non-ST elevation myocardial infarction admissions in 2000 was 1.10, and this increased in a linear fashion to 1.30 in 2013, representing an annual increase of 0.0148. The use of unlinked counts in epidemiological estimates of CHD hospitalisations overestimates CHD counts. The CA and 28-day episode counts are more aligned with epidemiological studies of CHD. The degree of overestimation of counts using only unlinked counts varies in a complex manner with CHD subtype, time, sex and age group, and it is not possible to apply a simple correction factor to counts obtained from unlinked data. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Atmospheric mold spore counts in relation to meteorological parameters

    Science.gov (United States)

    Katial, R. K.; Zhang, Yiming; Jones, Richard H.; Dyer, Philip D.

    Fungal spore counts of Cladosporium, Alternaria, and Epicoccum were studied during 8 years in Denver, Colorado. Fungal spore counts were obtained daily during the pollinating season by a Rotorod sampler. Weather data were obtained from the National Climatic Data Center. Daily averages of temperature, relative humidity, daily precipitation, barometric pressure, and wind speed were studied. A time series analysis was performed on the data to mathematically model the spore counts in relation to weather parameters. Using SAS PROC ARIMA software, a regression analysis was performed, regressing the spore counts on the weather variables assuming an autoregressive moving average (ARMA) error structure. Cladosporium was found to be positively correlated (Pmodel was derived for Cladosporium spore counts using the annual seasonal cycle and significant weather variables. The model for Alternaria and Epicoccum incorporated the annual seasonal cycle. Fungal spore counts can be modeled by time series analysis and related to meteorological parameters controlling for seasonallity; this modeling can provide estimates of exposure to fungal aeroallergens.

  9. Pixel-Cluster Counting Luminosity Measurement in ATLAS

    CERN Document Server

    McCormack, William Patrick; The ATLAS collaboration

    2016-01-01

    A precision measurement of the delivered luminosity is a key component of the ATLAS physics program at the Large Hadron Collider (LHC). A fundamental ingredient of the strategy to control the systematic uncertainties affecting the absolute luminosity has been to compare the measurements of several luminometers, most of which use more than one counting technique. The level of consistency across the various methods provides valuable cross-checks as well as an estimate of the detector-related systematic uncertainties. This poster describes the development of a luminosity algorithm based on pixel-cluster counting in the recently installed ATLAS inner b-layer (IBL), using data recorded during the 2015 pp run at the LHC. The noise and background contamination of the luminosity-associated cluster count is minimized by a multi-component fit to the measured cluster-size distribution in the forward pixel modules of the IBL. The linearity, long-term stability and statistical precision of the cluster-counting method are ...

  10. Pixel-Cluster Counting Luminosity Measurement In ATLAS

    CERN Document Server

    AUTHOR|(SzGeCERN)782710; The ATLAS collaboration

    2017-01-01

    A precision measurement of the delivered luminosity is a key component of the ATLAS physics program at the Large Hadron Collider (LHC). A fundamental ingredient of the strategy to control the systematic uncertainties affecting the absolute luminosity has been to compare the measure- ments of several luminometers, most of which use more than one counting technique. The level of consistency across the various methods provides valuable cross-checks as well as an estimate of the detector-related systematic uncertainties. This poster describes the development of a luminosity algorithm based on pixel-cluster counting in the recently installed ATLAS inner b-layer (IBL), using data recorded during the 2015 pp run at the LHC. The noise and background contamination of the luminosity-associated cluster count is minimized by a multi-component fit to the measured cluster-size distribution in the forward pixel modules of the IBL. The linearity, long-term stability and statistical precision of the cluster- counting method a...

  11. Investigation of reduction in background counts of clover detector

    International Nuclear Information System (INIS)

    Kshetri, Ritesh

    2015-01-01

    The peak-to-total ratio can be improved by increasing the full energy peak (FEP) counts and/or by decreasing the background counts. It is notable that FEP counts will be effected by mode of operation, while background counts will be effected by both modes of operation and suppression cases. It would be interesting to know if the reduction in background is caused more by active suppression or by add back process. We introduce a simple formalism to investigate the reduction of background counts for different cases-single crystal or add back mode with active or passive suppression. A more sophisticated formalism for modeling a general composite detector had been presented in a series of six recent papers by the author

  12. Passive non destructive assay of hull waste by gross neutron counting method

    International Nuclear Information System (INIS)

    Andola, Sanjay; Sur, Amit; Rawool, A.M.; Sharma, B.; Kaushik, T.C.; Gupta, S.C.; Basu, Sekhar; Raman Kumar; Agarwal, K.

    2014-01-01

    The special nuclear material accounting (SNMA) is an important and necessary issue now in nuclear waste management. The hull waste generated from dissolution of spent fuel contains small amounts of Uranium and Plutonium and other actinides due to undissolved trapped material inside zircoalloy tubes. We report here on the development of a Passive Hull monitoring system using gross neutron counting technique and its implementation with semiautomatic instrumentation. The overall sensitivity of the 3 He detector banks placed at 75 cm from the centre of loaded hull cask comes out to 5.2 x 10 -3 counts per neutron (c/n) while with standard Pu-Be source placed in same position it comes out to be 3.1 x 10 3 c/n. The difference in the efficiency is mainly because of the differences in the geometry and size of hull cask as well as difference in the energy spectrum of hull waste and Pu-Be source. This is accounted through Monte Carlo computations. The Pu mass in solid waste comes out as expected and varies with the surface dose rate of drum in almost a proportional manner. Being simple and less time consuming, this setup has been installed for routine assay of solid Hull waste at NRB, Tarapur

  13. Multiple sample, radioactive particle counting apparatus

    International Nuclear Information System (INIS)

    Reddy, R.R.V.; Kelso, D.M.

    1978-01-01

    An apparatus is described for determining the respective radioactive particle sample count being emitted from radioactive particle containing samples. It includes means for modulating the information on the radioactive particles being emitted from the samples, coded detecting means for sequentially detecting different respective coded combinations of the radioactive particles emitted from more than one but less than all of the samples, and processing the modulated information to derive the sample count for each sample. It includes a single light emitting crystal next to a number of samples, an encoder belt sequentially movable between the crystal and the samples. The encoder belt has a coded array of apertures to provide corresponding modulated light pulses from the crystal, and a photomultiplier tube to convert the modulated light pulses to decodable electrical signals for deriving the respective sample count

  14. CERN_DxCTA counting mode chip

    CERN Document Server

    Moraes, D; Nygård, E

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e−, for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors.

  15. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  16. A multiwire proportional counter for very high counting rates

    International Nuclear Information System (INIS)

    Barbosa, A.F.; Guedes, G.P.; Tamura, E.; Pepe, I.M.; Oliveira, N.B.

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10 6 counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10 7 events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author)

  17. Method of inspecting Raschig rings by neutron absorption counting

    International Nuclear Information System (INIS)

    Morris, R.N.; Murri, R.L.; Hume, M.W.

    1979-01-01

    A neutron counting method for inspecting borosilicate glass Raschig rings and an apparatus designed specifically for this method are discussed. The neutron count ratios for rings of a given thickness show a linear correlation to the boron oxide content of the rings. The count ratio also has a linear relationship to the thickness of rings of a given boron oxide content. Consequently, the experimentally-determined count ratio and physically-measured thickness of Raschig rings can be used to statistically predict their boron oxide content and determine whether or not they meet quality control acceptance criteria

  18. Double counting in LDA + DMFT-The example of NiO

    Energy Technology Data Exchange (ETDEWEB)

    Karolak, M., E-mail: mkarolak@physnet.uni-hamburg.d [I. Institut fuer Theoretische Physik, Universitaet Hamburg, Jungiusstrasse 9, D-20355 Hamburg (Germany); Ulm, G.; Wehling, T. [I. Institut fuer Theoretische Physik, Universitaet Hamburg, Jungiusstrasse 9, D-20355 Hamburg (Germany); Mazurenko, V. [Theoretical Physics and Applied Mathematic Department, Urals State Technical University, 620002, Mira street 19, Yekaterinburg (Russian Federation); Poteryaev, A. [Institute of Metal Physics, Russian Academy of Sciences, 620041 Yekaterinburg GSP-170 (Russian Federation); Lichtenstein, A. [I. Institut fuer Theoretische Physik, Universitaet Hamburg, Jungiusstrasse 9, D-20355 Hamburg (Germany)

    2010-07-15

    An intrinsic issue of the LDA + DMFT approach is the so called double counting of interaction terms. How to choose the double-counting potential in a manner that is both physically sound and consistent is unknown. We have conducted an extensive study of the charge-transfer system NiO in the LDA + DMFT framework using quantum Monte Carlo and exact diagonalization as impurity solvers. By explicitly treating the double-counting correction as an adjustable parameter we systematically investigated the effects of different choices for the double counting on the spectral function. Different methods for fixing the double counting can drive the result from Mott insulating to almost metallic. We propose a reasonable scheme for the determination of double-counting corrections for insulating systems.

  19. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  20. Application of RI-counting method for posttraumatic CSF rhinorrhea

    International Nuclear Information System (INIS)

    Itoh, Takahiko; Terai, Yoshinori; Fujimoto, Shunichiro; Kawauchi, Masamitsu.

    1987-01-01

    Numerous techniques and procedures have been reported for the evaluation of CSF fistulas. Especially metrizamide CT cisternography and radioisotope (RI) cisternography have been reported to be reliable for localizing the site of CSF leakage, however, it has been difficult to diagnose the existence and the site of CSF leakages in some cases. RI-counting method, measuring RI-count of intranasal cotton pledgets after the intrathecal injection of RI ( 111 In-DTPA) is thought to be the most reliable method for detecting the presence of CSF leakage in these cases. We used six cotton pledgets which were inserted into upper, middle, and lower meatuses on both side. Because the site of pledgets with ghest RI-count has anatomical relationship to the opening of the paranasal sinus, we can surmise the leakage of dural defect and CSF leakage. RI counting method was applied to two patients in whom it was difficult to diagnose the presence of CSF leakage with other procedures. The patients were free in position for four hours after the intrathecal injection of RI, and in the prone position for 30 minutes before RI-counting of intranasal cotton pledgets. After measuring the RI-counts of six pledgets, the counts were compared with each other. The cotton pledget inserted into left middle meatus showed the highest count in both cases. From this result and finding of conventional skull tomography we speculated the site of CSF leakage to be frontal sinus or ethmoid sinus. Operation demonstrated the opening of dura into the frontal sinus in one case, and ethmoid sinus in another case. As mentioned above, RI-counting method has the advantages of detecting the existence and the site of CSF leakage. (author)

  1. Is It Counting, or Is It Adding?

    Science.gov (United States)

    Eisenhardt, Sara; Fisher, Molly H.; Thomas, Jonathan; Schack, Edna O.; Tassell, Janet; Yoder, Margaret

    2014-01-01

    The Common Core State Standards for Mathematics (CCSSI 2010) expect second grade students to "fluently add and subtract within 20 using mental strategies" (2.OA.B.2). Most children begin with number word sequences and counting approximations and then develop greater skill with counting. But do all teachers really understand how this…

  2. 2013 Kids Count in Colorado! Community Matters

    Science.gov (United States)

    Colorado Children's Campaign, 2013

    2013-01-01

    "Kids Count in Colorado!" is an annual publication of the Children's Campaign, providing state and county level data on child well-being factors including child health, education, and economic status. Since its first release 20 years ago, "Kids Count in Colorado!" has become the most trusted source for data and information on…

  3. Implementation of a nonlinear filter for online nuclear counting

    International Nuclear Information System (INIS)

    Coulon, R.; Dumazert, J.; Kondrasovs, V.; Normand, S.

    2016-01-01

    Nuclear counting is a challenging task for nuclear instrumentation because of the stochastic nature of radioactivity. Event counting has to be processed and filtered to determine a stable count rate value and perform variation monitoring of the measured event. An innovative approach for nuclear counting is presented in this study, improving response time and maintaining count rate stability. Some nonlinear filters providing a local maximum likelihood estimation of the signal have been recently developed, which have been tested and compared with conventional linear filters. A nonlinear filter thus developed shows significant performance in terms of response time and measurement precision. The filter also presents the specificity of easy embedment into digital signal processor (DSP) electronics based on field-programmable gate arrays (FPGA) or microcontrollers, compatible with real-time requirements. © 2001 Elsevier Science. All rights reserved. - Highlights: • An efficient approach based on nonlinear filtering has been implemented. • The hypothesis test provides a local maximum likelihood estimation of the count rate. • The filter ensures an optimal compromise between precision and response time.

  4. Automatic spark counting of alpha-tracks in plastic foils

    International Nuclear Information System (INIS)

    Somogyi, G.; Medveczky, L.; Hunyadi, I.; Nyako, B.

    1976-01-01

    The possibility of alpha-track counting by jumping spark counter in cellulose acetate and polycarbonate nuclear track detectors was studied. A theoretical treatment is presented which predicts the optimum residual thickness of the etched foils in which completely through-etched tracks (i.e. holes) can be obtained for alpha-particles of various energies and angles of incidence. In agreement with the theoretical prediction it is shown that a successful spark counting of alpha-tracks can be performed even in polycarbonate foils. Some counting characteristics, such as counting efficiency vs particle energy at various etched foil thicknesses, surface spark density produced by electric breakdowns in unexposed foils vs foil thickness, etc. have been determined. Special attention was given to the spark counting of alpha-tracks entering thin detectors at right angle. The applicability of the spark counting technique is demonstrated in angular distribution measurements of the 27 Al(p,α 0 ) 24 Mg nuclear reaction at Ep = 1899 keV resonance energy. For this study 15 μm thick Makrofol-G foils and a jumping spark counter of improved construction were used. (orig.) [de

  5. Low-priced, time-saving, reliable and stable LR-115 counting system

    International Nuclear Information System (INIS)

    Tchorz-Trzeciakiewicz, D.E.

    2015-01-01

    Nuclear alpha particles leave etches (tracks) when they hit the surface of a LR-115 detector. The density of these tracks is used to measure radon concentration. Counting these tracks by human sense is tedious and time-consuming procedure and may introduce counting error, whereas most available automatic and semiautomatic counting systems are expensive or complex. An uncomplicated, robust, reliable and stable counting system using freely available on the Internet software as Digimizer™ and PhotoScape was developed and proposed. The effectiveness of the proposed procedure was evaluated by comparing the amount of tracks counted by software with the amount of tracks counted manually for 223 detectors. The percentage error for each analysed detector was obtained as a difference between automatic and manual counts divided by manual count. For more than 97% of detectors, the percentage errors oscillated between −3% and 3%. - Highlights: • Semiautomatic, uncomplicated procedure was proposed to count the amount of alpha tracks. • Freely available software on the Internet used as alpha tracks counting system for LR-115. • LR-115 detectors used to measure radon concentration and radon exhalation rate

  6. MR-based automatic delineation of volumes of interest in human brain PET images using probability maps

    DEFF Research Database (Denmark)

    Svarer, Claus; Madsen, Karina; Hasselbalch, Steen G.

    2005-01-01

    The purpose of this study was to develop and validate an observer-independent approach for automatic generation of volume-of-interest (VOI) brain templates to be used in emission tomography studies of the brain. The method utilizes a VOI probability map created on the basis of a database of several...... delineation of the VOI set. The approach was also shown to work equally well in individuals with pronounced cerebral atrophy. Probability-map-based automatic delineation of VOIs is a fast, objective, reproducible, and safe way to assess regional brain values from PET or SPECT scans. In addition, the method...

  7. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  8. Graphite nodule count and size distribution in thin-walled ductile cast iron

    DEFF Research Database (Denmark)

    Pedersen, Karl Martin; Tiedje, Niels Skat

    2008-01-01

    Graphite nodule count and size distribution have been analysed in thin walled ductile cast iron. The 2D nodule counts have been converted into 3D nodule count by using Finite Difference Method (FDM). Particles having a diameter smaller than 5 µm should be neglected in the nodule count as these ar......Graphite nodule count and size distribution have been analysed in thin walled ductile cast iron. The 2D nodule counts have been converted into 3D nodule count by using Finite Difference Method (FDM). Particles having a diameter smaller than 5 µm should be neglected in the nodule count...... as these are inclusions and micro porosities that do not influence the solidification morphology. If there are many small graphite nodules as in thin walled castings only 3D nodule count calculated by FDM will give reliable results. 2D nodule count and 3D nodule count calculated by simple equations will give too low...

  9. Calorie count - fast food

    Science.gov (United States)

    ... GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Calorie count - fast food URL of this page: //medlineplus.gov/ency/patientinstructions/ ...

  10. A multiwire proportional counter for very high counting rates

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, A F; Guedes, G P [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Tamura, E [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP (Brazil); Pepe, I M; Oliveira, N B [Bahia Univ., Salvador, BA (Brazil). Inst. de Fisica

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10{sup 6} counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10{sup 7} events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author) 13 refs., 6 figs.

  11. Counting on fine motor skills: links between preschool finger dexterity and numerical skills.

    Science.gov (United States)

    Fischer, Ursula; Suggate, Sebastian P; Schmirl, Judith; Stoeger, Heidrun

    2017-10-26

    Finger counting is widely considered an important step in children's early mathematical development. Presumably, children's ability to move their fingers during early counting experiences to aid number representation depends in part on their early fine motor skills (FMS). Specifically, FMS should link to children's procedural counting skills through consistent repetition of finger-counting procedures. Accordingly, we hypothesized that (a) FMS are linked to early counting skills, and (b) greater FMS relate to conceptual counting knowledge (e.g., cardinality, abstraction, order irrelevance) via procedural counting skills (i.e., one-one correspondence and correctness of verbal counting). Preschool children (N = 177) were administered measures of procedural counting skills, conceptual counting knowledge, FMS, and general cognitive skills along with parent questionnaires on home mathematics and fine motor environment. FMS correlated with procedural counting skills and conceptual counting knowledge after controlling for cognitive skills, chronological age, home mathematics and FMS environments. Moreover, the relationship between FMS and conceptual counting knowledge was mediated by procedural counting skills. Findings suggest that FMS play a role in early counting and therewith conceptual counting knowledge. © 2017 John Wiley & Sons Ltd.

  12. Loss-Free Counting with Digital Signal Processors

    International Nuclear Information System (INIS)

    Markku Koskelo; Dave Hall; Martin Moslinger

    2000-01-01

    Loss-free-counting (LFC) techniques have frequently been used with traditional analog pulse processing systems to compensate for the time or pulses lost when a spectroscopy system is unavailable (busy) for processing an accepted pulse. With the availability of second-generation digital signal processing (DSP) electronics that offer a significantly improved performance for both high and low count rate applications, the LFC technique has been revisited. Specific attention was given to the high and ultra-high count rate behavior, using high-purity germanium (HPGe) detectors with both transistor reset preamplifiers (TRP) and conventional RC preamplifiers. The experiments conducted for this work show that the known LFC techniques further benefit when combined with modern DSP pulse shaping

  13. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  14. Computed neutron coincidence counting applied to passive waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1997-01-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs

  15. Résultats de recherche | Page 2 | CRDI - Centre de recherches pour ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    En 2014, l'épidémie d'Ebola en Afrique de l'Ouest a coûté la vie à des dizaines de milliers de personnes, en particulier en Guinée, au Liberia et en Sierra Leone. Projet ... Le virus influenza provoque une infection des voies respiratoires supérieures chez les humains, les espèces aviaires et une variété de mammifères.

  16. Influence of materials and counting-rate effects on 3He neutron spectrometry

    International Nuclear Information System (INIS)

    Evans, A.E.

    1984-01-01

    The high energy resolution of the Cuttler-Shalev 3 He neutron spectrometer causes spectral measurements with this instrument to be strongly susceptible to artifacts caused by the presence of scattering or absorbing materials in or near the detector or the source, and to false peaks generated by pileup coincidences of the rather long-risetime pulses from the detector. These effects are particularly important when pulse-height distributions vary over several orders of magnitude in count rate versus channel. A commercial pile-up elimination circuit greatly improves but does not eliminate the pileup problem. Previously reported spurious peaks in the pulse-height distributions from monoenergetic neutron sources have been determined to be due to the influence of the iron in the detector wall. 6 references, 9 figures

  17. High Reproducibility of ELISPOT Counts from Nine Different Laboratories

    Directory of Open Access Journals (Sweden)

    Srividya Sundararaman

    2015-01-01

    Full Text Available The primary goal of immune monitoring with ELISPOT is to measure the number of T cells, specific for any antigen, accurately and reproducibly between different laboratories. In ELISPOT assays, antigen-specific T cells secrete cytokines, forming spots of different sizes on a membrane with variable background intensities. Due to the subjective nature of judging maximal and minimal spot sizes, different investigators come up with different numbers. This study aims to determine whether statistics-based, automated size-gating can harmonize the number of spot counts calculated between different laboratories. We plated PBMC at four different concentrations, 24 replicates each, in an IFN-γ ELISPOT assay with HCMV pp65 antigen. The ELISPOT plate, and an image file of the plate was counted in nine different laboratories using ImmunoSpot® Analyzers by (A Basic Count™ relying on subjective counting parameters set by the respective investigators and (B SmartCount™, an automated counting protocol by the ImmunoSpot® Software that uses statistics-based spot size auto-gating with spot intensity auto-thresholding. The average coefficient of variation (CV for the mean values between independent laboratories was 26.7% when counting with Basic Count™, and 6.7% when counting with SmartCount™. Our data indicates that SmartCount™ allows harmonization of counting ELISPOT results between different laboratories and investigators.

  18. A Word Count of Modern Arabic Prose.

    Science.gov (United States)

    Landau, Jacob M.

    This book presents a word count of Arabic prose based on 60 twentieth-century Egyptian books. The text is divided into an alphabetical list and a word frequency list. This word count is intended as an aid in the: (1) writing of primers and the compilation of graded readers, (2) examination of the vocabulary selection of primers and readers…

  19. On the Renormalization of the One–Pion Exchange Potential and the Consistency of Weinberg’s Power Counting

    International Nuclear Information System (INIS)

    Epelbaum, E.; Meißner, Ulf-G.

    2013-01-01

    Nogga, Timmermans and van Kolck recently argued that Weinberg’s power counting in the few–nucleon sector is inconsistent and requires modifications. Their argument is based on the observed cutoff dependence of the nucleon–nucleon scattering amplitude calculated by solving the Lippmann–Schwinger equation with the regularized one–pion exchange potential and the cutoff Λ varied in the range Λ = 2 . . . 20 fm −1 . In this paper we discuss the role the cutoff plays in the application of chiral effective field theory to the two–nucleon system and study carefully the cutoff–dependence of phase shifts and observables based on the one–pion exchange potential. We show that (i) there is no need to use the momentum–space cutoff larger than Λ ∼ 3 fm −1 ; (ii) the neutron–proton low–energy data show no evidence for an inconsistency of Weinberg’s power counting if one uses Λ ∼ 3 fm - 1. (author)

  20. Alaska Steller sea lion Count Database (Non-pups)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of adult and juvenile (non-pup) Steller sea lions on rookeries and haulouts in Alaska made between 1904 and 2015. Non-pup counts have...

  1. Proposals of counting method for bubble detectors and their intercomparisons

    International Nuclear Information System (INIS)

    Ramalho, Eduardo; Silva, Ademir X.; Bellido, Luis F.; Facure, Alessandro; Pereira, Mario

    2009-01-01

    The study of neutron's spectrometry and dosimetry has become significantly easier due to relatively new devices called bubble detectors. Insensitive to gamma rays and composed by superheated emulsions, they still are subjects of many researches in Radiation Physics and Nuclear Engineering. In bubble detectors, either exposed to more intense neutron fields or for a long time, when more bubbles are produced, the statistical uncertainty during the dosimetric and spectrometric processes is reduced. A proposal of this nature is set up in this work, which presents ways to perform counting processes for bubble detectors and an updated proceeding to get the irradiated detectors' images in order to make the manual counting easier. Twelve BDS detectors were irradiated by RDS111 cyclotron from IEN's (Instituto de Engenharia Nuclear) and photographed using an assembly specially designed for this experiment. Counting was proceeded manually in a first moment; simultaneously, ImagePro was used in order to perform counting automatically. The bubble counting values, either manual or automatic, were compared and the time to get them and their difficult levels as well. After the bubble counting, the detectors' standardizes responses were calculated in both cases, according to BDS's manual and they were also compared. Among the results, the counting on these devices really becomes very hard at a large number of bubbles, besides higher variations in counting of many bubbles. Because of the good agreement between manual counting and the custom program, the last one revealed a good alternative in practical and economical levels. Despite the good results, the custom program needs of more adjustments in order to achieve more accuracy on higher counting on bubble detectors for neutron measurement applications. (author)

  2. Learning to count begins in infancy: evidence from 18 month olds' visual preferences.

    Science.gov (United States)

    Slaughter, Virginia; Itakura, Shoji; Kutsuki, Aya; Siegal, Michael

    2011-10-07

    We used a preferential looking paradigm to evaluate infants' preferences for correct versus incorrect counting. Infants viewed a video depicting six fish. In the correct counting sequence, a hand pointed to each fish in turn, accompanied by verbal counting up to six. In the incorrect counting sequence, the hand moved between two of the six fish while there was still verbal counting to six, thereby violating the one-to-one correspondence principle of correct counting. Experiment 1 showed that Australian 18 month olds, but not 15 month olds, significantly preferred to watch the correct counting sequence. In experiment 2, Australian infants' preference for correct counting disappeared when the count words were replaced by beeps or by Japanese count words. In experiment 3, Japanese 18 month olds significantly preferred the correct counting video only when counting was in Japanese. These results show that infants start to acquire the abstract principles governing correct counting prior to producing any counting behaviour.

  3. Improving EWMA Plans for Detecting Unusual Increases in Poisson Counts

    Directory of Open Access Journals (Sweden)

    R. S. Sparks

    2009-01-01

    adaptive exponentially weighted moving average (EWMA plan is developed for signalling unusually high incidence when monitoring a time series of nonhomogeneous daily disease counts. A Poisson transitional regression model is used to fit background/expected trend in counts and provides “one-day-ahead” forecasts of the next day's count. Departures of counts from their forecasts are monitored. The paper outlines an approach for improving early outbreak data signals by dynamically adjusting the exponential weights to be efficient at signalling local persistent high side changes. We emphasise outbreak signals in steady-state situations; that is, changes that occur after the EWMA statistic had run through several in-control counts.

  4. Upper limits from counting experiments with multiple pipelines

    International Nuclear Information System (INIS)

    Sutton, Patrick J

    2009-01-01

    In counting experiments, one can set an upper limit on the rate of a Poisson process based on a count of the number of events observed due to the process. In some experiments, one makes several counts of the number of events, using different instruments, different event detection algorithms or observations over multiple time intervals. We demonstrate how to generalize the classical frequentist upper limit calculation to the case where multiple counts of events are made over one or more time intervals using several (not necessarily independent) procedures. We show how different choices of the rank ordering of possible outcomes in the space of counts correspond to applying different levels of significance to the various measurements. We propose an ordering that is matched to the sensitivity of the different measurement procedures and show that in typical cases it gives stronger upper limits than other choices. As an example, we show how this method can be applied to searches for gravitational-wave bursts, where multiple burst-detection algorithms analyse the same data set, and demonstrate how a single combined upper limit can be set on the gravitational-wave burst rate.

  5. Pill counts and pill rental: unintended entrepreneurial opportunities.

    Science.gov (United States)

    Viscomi, Christopher M; Covington, Melissa; Christenson, Catherine

    2013-07-01

    Prescription opioid diversion and abuse are becoming increasingly prevalent in many regions of the world, particularly the United States. One method advocated to assess compliance with opioid prescriptions is occasional "pill counts." Shortly before a scheduled appointment, a patient is notified that they must bring in the unused portion of their opioid prescription. It has been assumed that if a patient has the correct number and strength of pills that should be present for that point in a prescription interval that they are unlikely to be selling or abusing their opioids. Two cases are presented where patients describe short term rental of opioids from illicit opioid dealers in order to circumvent pill counts. Pill renting appears to be an established method of circumventing pill counts. Pill counts do not assure non-diversion of opioids and provide additional cash flow to illicit opioid dealers.

  6. Big drop. [Decline in sperm counts from environmental pollution

    Energy Technology Data Exchange (ETDEWEB)

    Castleman, M.

    Statisticians at the University of Copenhagen have published a review of sperm-count studies carried out from 1938-1990. After controlling for such things as counting techniques and sexual activity, they found that average sperm counts have decreased 42% over the last 50 years. After eliminating possible causes such as heat and differences in counting techniques, the only plausible cause left was environmental pollution. This finding correlates with a study performed in 1979 which found abnormally high concentrations of such toxic pollutants as DDT and PCBs in semen. The Copenhagen study suggests that even at low levels of exposure, environmental pollution is having biological consequences.

  7. Fitting a distribution to miccrobial counts: making sense of zeros

    DEFF Research Database (Denmark)

    Ribeiro Duarte, Ana Sofia; Stockmarr, Anders; Nauta, Maarten

    and standard deviation) and the prevalence of contaminated food units (one minus the proportion of “true zeros”) from a set of microbial counts. By running the model with in silico generated concentration and count data, we could evaluate the performance of this method in terms of estimation of the three......Non-detects or left-censored results are inherent to the traditional methods of microbial enumeration in foods. Typically, a low concentration of microorganisms in a food unit goes undetected in plate counts or most probable number (MPN) counts, and produces “artificial zeros”. However......, these “artificial zeros” are only a share of the total number of zero counts resulting from a sample, as their number adds up to the number of “true zeros” resulting from uncontaminated units. In the process of fitting a probability distribution to microbial counts, “artificial” and “true” zeros are usually...

  8. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  9. Modeling Repeated Count Data : Some Extensions of the Rasch Poisson Counts Model

    NARCIS (Netherlands)

    van Duijn, M.A.J.; Jansen, Margo

    1995-01-01

    We consider data that can be summarized as an N X K table of counts-for example, test data obtained by administering K tests to N subjects. The cell entries y(ij) are assumed to be conditionally independent Poisson-distributed random variables, given the NK Poisson intensity parameters mu(ij). The

  10. Two, four, six, eight... stop and count before it is too late! An audit on swab, needle and instrument counts in theatre.

    LENUS (Irish Health Repository)

    Donnelly, T.

    2014-07-01

    A concurrent audit was conducted over a four week period to determine if the counting of swabs, needles and instruments for surgery adhered to local policy and recommended guidelines. Data were collected on 30 abdominal surgical procedures. This audit highlighted failings in the count process. It identified poor communication within the multidisciplinary team. There needs to be an increased awareness about local policy, national and international guidelines regarding the counting of swabs, needles and instruments for all surgical procedures.

  11. Limit of sensitivity of low-background counting equipment

    International Nuclear Information System (INIS)

    Homann, S.G.

    1991-01-01

    The Hazards Control Department's Radiological Measurements Laboratory (RML) analyzes many types of sample media in support of the Laboratory's health and safety program. The Department has determined that the equation for the minimum limit of sensitivity, MDC(α,β) = 2.71 + 3.29 (r b t s ) 1/2 is also adequate for RML counting systems with very-low-background levels. This paper reviews the normal distribution case and address the special case of determining the limit of sensitivity of a counting system when the background count rate is well known and small. In the latter case, we must use an exact test procedure based on the binomial distribution. However, the error in using the normal distribution for calculating a detection system's limit of sensitivity is not significant even as the total observed number of counts approaches or equals zero. 2 refs., 4 figs

  12. An Automatic Car Counting System Using OverFeat Framework

    Directory of Open Access Journals (Sweden)

    Debojit Biswas

    2017-06-01

    Full Text Available Automatic car counting is an important component in the automated traffic system. Car counting is very important to understand the traffic load and optimize the traffic signals. In this paper, we implemented the Gaussian Background Subtraction Method and OverFeat Framework to count cars. OverFeat Framework is a combination of Convolution Neural Network (CNN and one machine learning classifier (like Support Vector Machines (SVM or Logistic Regression. With this study, we showed another possible application area for the OverFeat Framework. The advantages and shortcomings of the Background Subtraction Method and OverFeat Framework were analyzed using six individual traffic videos with different perspectives, such as camera angles, weather conditions and time of the day. In addition, we compared the two algorithms above with manual counting and a commercial software called Placemeter. The OverFeat Framework showed significant potential in the field of car counting with the average accuracy of 96.55% in our experiment.

  13. An Automatic Car Counting System Using OverFeat Framework.

    Science.gov (United States)

    Biswas, Debojit; Su, Hongbo; Wang, Chengyi; Blankenship, Jason; Stevanovic, Aleksandar

    2017-06-30

    Automatic car counting is an important component in the automated traffic system. Car counting is very important to understand the traffic load and optimize the traffic signals. In this paper, we implemented the Gaussian Background Subtraction Method and OverFeat Framework to count cars. OverFeat Framework is a combination of Convolution Neural Network (CNN) and one machine learning classifier (like Support Vector Machines (SVM) or Logistic Regression). With this study, we showed another possible application area for the OverFeat Framework. The advantages and shortcomings of the Background Subtraction Method and OverFeat Framework were analyzed using six individual traffic videos with different perspectives, such as camera angles, weather conditions and time of the day. In addition, we compared the two algorithms above with manual counting and a commercial software called Placemeter. The OverFeat Framework showed significant potential in the field of car counting with the average accuracy of 96.55% in our experiment.

  14. The Copenhagen primary care differential count (CopDiff) database

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, V.; Karlslund, W.

    2014-01-01

    BACKGROUND: The differential blood cell count provides valuable information about a person's state of health. Together with a variety of biochemical variables, these analyses describe important physiological and pathophysiological relations. There is a need for research databases to explore assoc...... the construction of the Copenhagen Primary Care Differential Count database as well as the distribution of characteristics of the population it covers and the variables that are recorded. Finally, it gives examples of its use as an inspiration to peers for collaboration.......BACKGROUND: The differential blood cell count provides valuable information about a person's state of health. Together with a variety of biochemical variables, these analyses describe important physiological and pathophysiological relations. There is a need for research databases to explore...... Practitioners' Laboratory has registered all analytical results since July 1, 2000. The Copenhagen Primary Care Differential Count database contains all differential blood cell count results (n=1,308,022) from July 1, 2000 to January 25, 2010 requested by general practitioners, along with results from analysis...

  15. Relationship between γ detection dead-time and count correction factor

    International Nuclear Information System (INIS)

    Wu Huailong; Zhang Jianhua; Chu Chengsheng; Hu Guangchun; Zhang Changfan; Hu Gen; Gong Jian; Tian Dongfeng

    2015-01-01

    The relationship between dead-time and count correction factor was investigated by using interference source for purpose of high γ activity measurement. The count rates maintain several 10 s"-"l with γ energy of 0.3-1.3 MeV for 10"4-10"5 Bq radioactive source. It is proved that the relationship between count loss and dead-time is unconcerned at various energy and various count intensities. The same correction formula can be used for any nuclide measurement. (authors)

  16. Manifold-Based Visual Object Counting.

    Science.gov (United States)

    Wang, Yi; Zou, Yuexian; Wang, Wenwu

    2018-07-01

    Visual object counting (VOC) is an emerging area in computer vision which aims to estimate the number of objects of interest in a given image or video. Recently, object density based estimation method is shown to be promising for object counting as well as rough instance localization. However, the performance of this method tends to degrade when dealing with new objects and scenes. To address this limitation, we propose a manifold-based method for visual object counting (M-VOC), based on the manifold assumption that similar image patches share similar object densities. Firstly, the local geometry of a given image patch is represented linearly by its neighbors using a predefined patch training set, and the object density of this given image patch is reconstructed by preserving the local geometry using locally linear embedding. To improve the characterization of local geometry, additional constraints such as sparsity and non-negativity are also considered via regularization, nonlinear mapping, and kernel trick. Compared with the state-of-the-art VOC methods, our proposed M-VOC methods achieve competitive performance on seven benchmark datasets. Experiments verify that the proposed M-VOC methods have several favorable properties, such as robustness to the variation in the size of training dataset and image resolution, as often encountered in real-world VOC applications.

  17. Limits of reliability for the measurement of integral count

    International Nuclear Information System (INIS)

    Erbeszkorn, L.

    1979-01-01

    A method is presented for exact and approximate calculation of reliability limits of measured nuclear integral count. The formulae are applicable in measuring conditions which assure the Poisson distribution of the counts. The coefficients of the approximate formulae for 90, 95, 98 and 99 per cent reliability levels are given. The exact reliability limits for 90 per cent reliability level are calculated up to 80 integral counts. (R.J.)

  18. Quantitative Compton suppression spectrometry at elevated counting rates

    International Nuclear Information System (INIS)

    Westphal, G.P.; Joestl, K.; Schroeder, P.; Lauster, R.; Hausch, E.

    1999-01-01

    For quantitative Compton suppression spectrometry the decrease of coincidence efficiency with counting rate should be made negligible to avoid a virtual increase of relative peak areas of coincident isomeric transitions with counting rate. To that aim, a separate amplifier and discriminator has been used for each of the eight segments of the active shield of a new well-type Compton suppression spectrometer, together with an optimized, minimum dead-time design of the anticoincidence logic circuitry. Chance coincidence losses in the Compton suppression spectrometer are corrected instrumentally by comparing the chance coincidence rate to the counting rate of the germanium detector in a pulse-counting Busy circuit (G.P. Westphal, J. Rad. Chem. 179 (1994) 55) which is combined with the spectrometer's LFC counting loss correction system. The normally not observable chance coincidence rate is reconstructed from the rates of germanium detector and scintillation detector in an auxiliary coincidence unit, after the destruction of true coincidence by delaying one of the coincidence partners. Quantitative system response has been tested in two-source measurements with a fixed reference source of 60 Co of 14 kc/s, and various samples of 137 Cs, up to aggregate counting rates of 180 kc/s for the well-type detector, and more than 1400 kc/s for the BGO shield. In these measurements, the net peak areas of the 1173.3 keV line of 60 Co remained constant at typical values of 37 000 with and 95 000 without Compton suppression, with maximum deviations from the average of less than 1.5%

  19. Tutorial on Using Regression Models with Count Outcomes Using R

    Directory of Open Access Journals (Sweden)

    A. Alexander Beaujean

    2016-02-01

    Full Text Available Education researchers often study count variables, such as times a student reached a goal, discipline referrals, and absences. Most researchers that study these variables use typical regression methods (i.e., ordinary least-squares either with or without transforming the count variables. In either case, using typical regression for count data can produce parameter estimates that are biased, thus diminishing any inferences made from such data. As count-variable regression models are seldom taught in training programs, we present a tutorial to help educational researchers use such methods in their own research. We demonstrate analyzing and interpreting count data using Poisson, negative binomial, zero-inflated Poisson, and zero-inflated negative binomial regression models. The count regression methods are introduced through an example using the number of times students skipped class. The data for this example are freely available and the R syntax used run the example analyses are included in the Appendix.

  20. Pedestrian count estimation using texture feature with spatial distribution

    Directory of Open Access Journals (Sweden)

    Hongyu Hu

    2016-12-01

    Full Text Available We present a novel pedestrian count estimation approach based on global image descriptors formed from multi-scale texture features that considers spatial distribution. For regions of interest, local texture features are represented based on histograms of multi-scale block local binary pattern, which jointly constitute the feature vector of the whole image. Therefore, to achieve an effective estimation of pedestrian count, principal component analysis is used to reduce the dimension of the global representation features, and a fitting model between image global features and pedestrian count is constructed via support vector regression. The experimental result shows that the proposed method exhibits high accuracy on pedestrian count estimation and can be applied well in the real world.

  1. Sperm count. Do we need a new reference value?

    Science.gov (United States)

    Cardona Maya, Walter

    2010-03-01

    To evaluate the sperm count in fertile men, general population, and infertile men in different regions of the world. Sperm counts were recorded according to their fertility status, proven fertility, men recruited from an andrology/infertility clinic, or healthy men. The average of sperm count in the different studies is lower in infertile men that in fertile men (p>0.001) and in the general population (p>0.001). Based on this analysis the normal sperm count is about 65 million per mL. Using these reference value, only the 25% of the studies in infertile men are above this value, and the 75% studies with fertile men (>65 x 106 sperm/mL).

  2. Detectors for proton counting. Si-APD and scintillation detectors

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2008-01-01

    Increased intensity of synchrotron radiation requests users to prepare photon pulse detectors having higher counting rates. As detectors for photon counting, silicon-avalanche photodiode (Si-APD) and scintillation detectors were chosen for the fifth series of detectors. Principle of photon detection by pulse and need of amplification function of the detector were described. Structure and working principle, high counting rate measurement system, bunch of electrons vs. counting rate, application example of NMR time spectroscopy measurement and comments for users were described for the Si-APD detector. Structure of scintillator and photomultiplier tube, characteristics of scintillator and performance of detector were shown for the NaI detector. Future development of photon pulse detectors was discussed. (T. Tanaka)

  3. Problems associated with scintillation counting of NaH14CO3 and gel suspension counting of Ba14CO3

    International Nuclear Information System (INIS)

    MacRae, J.C.; Wilson, S.

    1978-01-01

    Liquid NaH 14 CO 3 was assayed in emulsion-type (NE260 and Unisolve) and dioxan-based (NE250) scintillation cocktails contained in glass or polyethylene vials kept at 2 0 or 24-30 0 C. Different particle size ranges of standard Ba 14 CO 3 were assayed by gel suspension counting in Cabosil scintillation cocktail and in NE260 following solubilisation in EDTA-tetrasodium salt. Initial detectable activities of NaH 14 CO 3 in glass and polyethylene vials in NE250, NE260 and Unisolve were 97 and 96, 68 and 83, 71 and 89% of the true value respectively. Subsequent losses of activity over 7 days with the emulsion-type scintillators was greater from the polyethylene vials. Addition of phenylethylamine to the NE260 and Unisolve cocktails gave the true activity levels for all vials with no loss of activity over 6 days. When different particle size ranges of Standard Ba 14 CO 3 were suspended in Cabosil scintillation cocktail there was considerable variation in counting efficiency (77-88%) with little relationship between particle size and counting efficiency. The relationship between counting efficiency and channels ratio was not sufficiently precise for predictive purposes. Solubilisation of Ba 14 CO 3 in EDTA-tetrasodium salt gave similar counting efficiency and channels ratio values for all samples. (U.K.)

  4. An investigation of kV CBCT image quality and dose reduction for volume-of-interest imaging using dynamic collimation

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, David, E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca [Department of Physics and Atmospheric Science, Dalhousie University, 5820 University Avenue, Halifax, Nova Scotia B3H 1V7 (Canada); Robar, James L., E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca [Department of Radiation Oncology and Department of Physics and Atmospheric Science, Dalhousie University, 5820 University Avenue, Halifax, Nova Scotia B3H 1V7 (Canada)

    2015-09-15

    Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kilovoltage-cone beam CT (CBCT) using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of 1D translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian On-Board Imager system. CBCT and planar image quality were investigated as a function of aperture radius, while maintaining the same dose to the VOI, for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various sizes VOI were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 to 2.4 cm (at isocenter). Depending upon VOI location and size, dose was reduced to 16%–90% of the full-field value along the central axis plane and down to 4% along the axis of rotation, while maintaining the same dose to the VOI compared to full-field techniques. When maintaining constant dose to the VOI, this change in iris diameter corresponds to a factor increase of approximately 1.6 in image contrast and a factor decrease in image noise of approximately 1.2. This results in a measured gain in contrast-to-noise ratio by a factor of approximately 2.0. Conclusions: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.

  5. Principal component and volume of interest analyses in depressed patients imaged by {sup 99m}Tc-HMPAO SPET: a methodological comparison

    Energy Technology Data Exchange (ETDEWEB)

    Pagani, Marco [Institute of Cognitive Sciences and Technologies, CNR, Rome (Italy); Section of Nuclear Medicine, Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Gardner, Ann; Haellstroem, Tore [NEUROTEC, Division of Psychiatry, Karolinska Institutet, Huddinge University Hospital, Stockholm (Sweden); Salmaso, Dario [Institute of Cognitive Sciences and Technologies, CNR, Rome (Italy); Sanchez Crespo, Alejandro; Jonsson, Cathrine; Larsson, Stig A. [Section of Nuclear Medicine, Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Jacobsson, Hans [Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Lindberg, Greger [Department of Medicine, Division of Gastroenterology and Hepatology, Karolinska Institutet, Huddinge University Hospital, Stockholm (Sweden); Waegner, Anna [Department of Clinical Neuroscience, Division of Neurology, Karolinska Hospital, Stockholm (Sweden)

    2004-07-01

    Previous regional cerebral blood flow (rCBF) studies on patients with unipolar major depressive disorder (MDD) have analysed clusters of voxels or single regions and yielded conflicting results, showing either higher or lower rCBF in MDD as compared to normal controls (CTR). The aim of this study was to assess rCBF distribution changes in 68 MDD patients, investigating the data set with both volume of interest (VOI) analysis and principal component analysis (PCA). The rCBF distribution in 68 MDD and 66 CTR, at rest, was compared. Technetium-99m d,l-hexamethylpropylene amine oxime single-photon emission tomography was performed and the uptake in 27 VOIs, bilaterally, was assessed using a standardising brain atlas. Data were then grouped into factors by means of PCA performed on rCBF of all 134 subjects and based on all 54 VOIs. VOI analysis showed a significant group x VOI x hemisphere interaction (P<0.001). rCBF in eight VOIs (in the prefrontal, temporal, occipital and central structures) differed significantly between groups at the P<0.05 level. PCA identified 11 anatomo-functional regions that interacted with groups (P<0.001). As compared to CTR, MDD rCBF was relatively higher in right associative temporo-parietal-occipital cortex (P<0.01) and bilaterally in prefrontal (P<0.005) and frontal cortex (P<0.025), anterior temporal cortex and central structures (P<0.05 and P<0.001 respectively). Higher rCBF in a selected group of MDD as compared to CTR at rest was found using PCA in five clusters of regions sharing close anatomical and functional relationships. At the single VOI level, all eight regions showing group differences were included in such clusters. PCA is a data-driven method for recasting VOIs to be used for group evaluation and comparison. The appearance of significant differences absent at the VOI level emphasises the value of analysing the relationships among brain regions for the investigation of psychiatric disease. (orig.)

  6. Single electron counting using a dual MCP assembly

    International Nuclear Information System (INIS)

    Yang, Yuzhen; Liu, Shulin; Zhao, Tianchi; Yan, Baojun; Wang, Peiliang; Yu, Yang; Lei, Xiangcui; Yang, Luping; Wen, Kaile; Qi, Ming

    2016-01-01

    The gain, pulse height resolution and peak-to-valley ratio of single electrons detected by using a Chevron configured Microchannel Plate (MCP) assembly are studied. The two MCPs are separated by a 280 µm gap and are biased by four electrodes. The purpose of the study is to determine the optimum bias voltage arrangements for single electron counting. By comparing the results of various bias voltage combinations, we conclude that good performance for the electron counting can be achieved by operating the MCP assembly in saturation mode. In addition, by applying a small reverse bias voltage across the gap while adjusting the bias voltages of the MCPs, optimum performance of electron counting can be obtained. - Highlights: • Dual MCPs assembly with four electrodes using different voltage combinations has been investigated for single electron counting. • Both the MCP voltages and the gap voltage can affect the gain, pulse height resolution and P/V ratio. • A high gain of the first stage MCP, a saturation mode of the second stage MCP and an appropriately reverse gap voltage can improve the resolution greatly. • The optimum voltage arrangements is significant for the design of MCP detectors in single electron counting applications.

  7. Real-time passenger counting by active linear cameras

    Science.gov (United States)

    Khoudour, Louahdi; Duvieubourg, Luc; Deparis, Jean-Pierre

    1996-03-01

    The companies operating subways are very much concerned with counting the passengers traveling through their transport systems. One of the most widely used systems for counting passengers consists of a mechanical gate equipped with a counter. However, such simple systems are not able to count passengers jumping above the gates. Moreover, passengers carrying large luggage or bags may meet some difficulties when going through such gates. The ideal solution is a contact-free counting system that would bring more comfort of use for the passengers. For these reasons, we propose to use a video processing system instead of these mechanical gates. The optical sensors discussed in this paper offer several advantages including well defined detection areas, fast response time and reliable counting capability. A new technology has been developed and tested, based on linear cameras. Preliminary results show that this system is very efficient when the passengers crossing the optical gate are well separated. In other cases, such as in compact crowd conditions, reasonable accuracy has been demonstrated. These results are illustrated by means of a number of sequences shot in field conditions. It is our belief that more precise measurements could be achieved, in the case of compact crowd, by other algorithms and acquisition techniques of the line images that we are presently developing.

  8. Spark counting technique with an aluminium oxide film

    International Nuclear Information System (INIS)

    Kawai, H.; Koga, T.; Morishima, H.; Niwa, T.; Nishiwaki, Y.

    1980-01-01

    Automatic spark counting of etch-pits on a polycarbonate film produced by nuclear fission fragments is now used for neutron monitoring in several countries. A method was developed using an aluminium oxide film instead of a polycarbonate as the neutron detector. Aluminium oxide films were prepared as follows: A cleaned aluminium plate as an anode and a nickel plate as a cathode were immersed in dilute sulfuric acid solution and electric current flowed between the electrodes at 12degC for 10-30 minutes. Electric current density was about 10 mA/cm 2 . The aluminium plate was then kept in boiling water for 10-30 minutes for sealing. The thickness of the aluminium oxide layer formed was about 1μm. The aluminium plate attached to a plate of suitable fissionable material, such as uranium or thorium, was irradiated with neutrons and set in a usual spark counter for fission track counting. One electrode was the aluminium plate and the other was an aluminized polyester sheet. Sparked pulses were counted with a usual scaler. The advantage of using spark counting with an aluminium oxide film for neutron monitoring is rapid measurement of neutron exposure, since chemical etching which is indispensable for spark counting with a polycarbonate detector film, is not needed. (H.K.)

  9. Fluorescent Biosensors Based on Single-Molecule Counting.

    Science.gov (United States)

    Ma, Fei; Li, Ying; Tang, Bo; Zhang, Chun-Yang

    2016-09-20

    Biosensors for highly sensitive, selective, and rapid quantification of specific biomolecules make great contributions to biomedical research, especially molecular diagnostics. However, conventional methods for biomolecular assays often suffer from insufficient sensitivity and poor specificity. In some case (e.g., early disease diagnostics), the concentration of target biomolecules is too low to be detected by these routine approaches, and cumbersome procedures are needed to improve the detection sensitivity. Therefore, there is an urgent need for rapid and ultrasensitive analytical tools. In this respect, single-molecule fluorescence approaches may well satisfy the requirement and hold promising potential for the development of ultrasensitive biosensors. Encouragingly, owing to the advances in single-molecule microscopy and spectroscopy over past decades, the detection of single fluorescent molecule comes true, greatly boosting the development of highly sensitive biosensors. By in vitro/in vivo labeling of target biomolecules with proper fluorescent tags, the quantification of certain biomolecule at the single-molecule level is achieved. In comparison with conventional ensemble measurements, single-molecule detection-based analytical methods possess the advantages of ultrahigh sensitivity, good selectivity, rapid analysis time, and low sample consumption. Consequently, single-molecule detection may be potentially employed as an ideal analytical approach to quantify low-abundant biomolecules with rapidity and simplicity. In this Account, we will summarize our efforts for developing a series of ultrasensitive biosensors based on single-molecule counting. Single-molecule counting is a member of single-molecule detection technologies and may be used as a very simple and ultrasensitive method to quantify target molecules by simply counting the individual fluorescent bursts. In the fluorescent sensors, the signals of target biomolecules may be translated to the

  10. An Automatic Car Counting System Using OverFeat Framework

    OpenAIRE

    Biswas, Debojit; Su, Hongbo; Wang, Chengyi; Blankenship, Jason; Stevanovic, Aleksandar

    2017-01-01

    Automatic car counting is an important component in the automated traffic system. Car counting is very important to understand the traffic load and optimize the traffic signals. In this paper, we implemented the Gaussian Background Subtraction Method and OverFeat Framework to count cars. OverFeat Framework is a combination of Convolution Neural Network (CNN) and one machine learning classifier (like Support Vector Machines (SVM) or Logistic Regression). With this study, we showed another poss...

  11. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  12. Automation system for optical counting of nuclear tracks

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F.; Boulyga, E.G.; Lomonosova, E.M.; Zhuk, I.V

    1999-06-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2{center_dot}10{sup 5} tracks/cm{sup 2}. The automatic system was applied in the experimental investigation of uranium and transuranium elements.

  13. Automation system for optical counting of nuclear tracks

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Boulyga, E.G.; Lomonosova, E.M.; Zhuk, I.V.

    1999-01-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2·10 5 tracks/cm 2 . The automatic system was applied in the experimental investigation of uranium and transuranium elements

  14. Automation system for optical counting of nuclear tracks

    CERN Document Server

    Boulyga, S F; Lomonosova, E M; Zhuk, I V

    1999-01-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2 centre dot 10 sup 5 tracks/cm sup 2. The automatic system was applied in the experimental investigation of uranium and transuranium elements.

  15. Relationship of milking rate to somatic cell count.

    Science.gov (United States)

    Brown, C A; Rischette, S J; Schultz, L H

    1986-03-01

    Information on milking rate, monthly bucket somatic cell counts, mastitis treatment, and milk production was obtained from 284 lactations of Holstein cows separated into three lactation groups. Significant correlations between somatic cell count (linear score) and other parameters included production in lactation 1 (-.185), production in lactation 2 (-.267), and percent 2-min milk in lactation 2 (.251). Somatic cell count tended to increase with maximum milking rate in all lactations, but correlations were not statistically significant. Twenty-nine percent of cows with milking rate measurements were treated for clinical mastitis. Treated cows in each lactation group produced less milk than untreated cows. In the second and third lactation groups, treated cows had a shorter total milking time and a higher percent 2-min milk than untreated cows, but differences were not statistically significant. Overall, the data support the concept that faster milking cows tend to have higher cell counts and more mastitis treatments, particularly beyond first lactation. However, the magnitude of the relationship was small.

  16. An automated approach for annual layer counting in ice cores

    Science.gov (United States)

    Winstrup, M.; Svensson, A.; Rasmussen, S. O.; Winther, O.; Steig, E.; Axelrod, A.

    2012-04-01

    The temporal resolution of some ice cores is sufficient to preserve seasonal information in the ice core record. In such cases, annual layer counting represents one of the most accurate methods to produce a chronology for the core. Yet, manual layer counting is a tedious and sometimes ambiguous job. As reliable layer recognition becomes more difficult, a manual approach increasingly relies on human interpretation of the available data. Thus, much may be gained by an automated and therefore objective approach for annual layer identification in ice cores. We have developed a novel method for automated annual layer counting in ice cores, which relies on Bayesian statistics. It uses algorithms from the statistical framework of Hidden Markov Models (HMM), originally developed for use in machine speech recognition. The strength of this layer detection algorithm lies in the way it is able to imitate the manual procedures for annual layer counting, while being based on purely objective criteria for annual layer identification. With this methodology, it is possible to determine the most likely position of multiple layer boundaries in an entire section of ice core data at once. It provides a probabilistic uncertainty estimate of the resulting layer count, hence ensuring a proper treatment of ambiguous layer boundaries in the data. Furthermore multiple data series can be incorporated to be used at once, hence allowing for a full multi-parameter annual layer counting method similar to a manual approach. In this study, the automated layer counting algorithm has been applied to data from the NGRIP ice core, Greenland. The NGRIP ice core has very high temporal resolution with depth, and hence the potential to be dated by annual layer counting far back in time. In previous studies [Andersen et al., 2006; Svensson et al., 2008], manual layer counting has been carried out back to 60 kyr BP. A comparison between the counted annual layers based on the two approaches will be presented

  17. Counting Triangles to Sum Squares

    Science.gov (United States)

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  18. Mutual interference of alpha and beta signals in counting

    International Nuclear Information System (INIS)

    Zhang Fengxiang; Ren Wei; Tang Shaohua; Han Suping; Du Xiangyang.

    1993-01-01

    When multi-wire proportional counters are used for monitoring of mixed contamination of α and β radioactivity, both of the signals should be distinguished as far as possible from requirement of radiation protection. The rules provided by the recommendation standard of International Electrotechnical Committee (IEC) and the national standard of China indicate: For fixed personal surface contamination monitoring assembly, the response of the α-counting channel to β events should be smaller than 1% of response of the α-counting channel to α events, and the response of β-counting channel to β events should be smaller than that of the response of α-counting channel to the same events. To distinguish one kind of signal from another, amplitude discrimination method is used usually. (3 figs)

  19. A new stratification of mourning dove call-count routes

    Science.gov (United States)

    Blankenship, L.H.; Humphrey, A.B.; MacDonald, D.

    1971-01-01

    The mourning dove (Zenaidura macroura) call-count survey is a nationwide audio-census of breeding mourning doves. Recent analyses of the call-count routes have utilized a stratification based upon physiographic regions of the United States. An analysis of 5 years of call-count data, based upon stratification using potential natural vegetation, has demonstrated that this uew stratification results in strata with greater homogeneity than the physiographic strata, provides lower error variance, and hence generates greatet precision in the analysis without an increase in call-count routes. Error variance was reduced approximately 30 percent for the contiguous United States. This indicates that future analysis based upon the new stratification will result in an increased ability to detect significant year-to-year changes.

  20. Metal ion levels and lymphocyte counts

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Varmarken, Jens-Erik; Ovesen, Ole

    2013-01-01

    BACKGROUND AND PURPOSE: Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA) an....../ppb. INTERPRETATION: Circulating T-lymphocyte levels may decline after surgery, regardless of implant type. Metal ions-particularly cobalt-may have a general depressive effect on T- and B-lymphocyte levels. Registered with ClinicalTrials.gov under # NCT01113762.......BACKGROUND AND PURPOSE: Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA....... RESULTS: The T-lymphocyte counts for both implant types declined over the 2-year period. This decline was statistically significant for CD3(+)CD8(+) in the THA group, with a regression coefficient of -0.04 × 10(9)cells/year (95% CI: -0.08 to -0.01). Regression analysis indicated a depressive effect...

  1. Theory and application of Cerenkov counting

    Energy Technology Data Exchange (ETDEWEB)

    Ross, H.H.

    1976-01-01

    The production of Cherenkov radiation by charged particles moving through a transparent medium (the Cherenkov generator) is a strictly physical process that is virtually independent of the chemistry of the medium. Thus, it is possible to calculate easily all of the important parameters of the Cherenkov process such as excitation threshold, emission intensity, spectral distribution, directional characteristics, and time response. The results of many of these physical effects are unknown in conventional liquid scintillation spectroscopy and, therefore, many unique assay techniques have been developed as a result of their consideration. This paper discusses the theoretical basis of the Cherenkov process, explores the unusual characteristics of the phenomenon, and demonstrates how these unusual characteristics can be used to develop equally unusual counting methodologies. Particular emphasis is directed toward an analysis of published data (obtained with conventional liquid scintillation instrumentation) that would be difficult or impossible to obtain with other counting techniques. Also discussed is a new type of sample vial that uses an isolated waveshifting system. The device was specifically designed for Cherenkov counting.

  2. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  3. Sperm motility and morphology as changing parameters linked to sperm count variations.

    OpenAIRE

    Dua A; Vaidya S

    1996-01-01

    Variations in semen analyses of 177 males over a 1 year period were assessed. The average means of total counts, motility, morphology, total motile count and non-motile % were determined for 5 classes of patients ranging from azoospermic to normospermic. Positive relationships between a falling sperm count, a decrease in motility and total motile counts were seen. Also, increasingly, abnormal forms were found with lower sperm counts.

  4. Platelet count is associated with cardiovascular disease, cancer and mortality

    DEFF Research Database (Denmark)

    Vinholt, P J; Hvas, A M; Frederiksen, H

    2016-01-01

    count (100-450×10(9)/L) and mortality, development of future cardiovascular disease (myocardial infarction, ischaemic stroke, or peripheral vascular disease), venous thromboembolism, bleeding or cancer in the general population. MATERIAL AND METHODS: We conducted a register-based cohort study of 21......,252 adults (≥20years) from the Danish General Suburban Population Study (GESUS). Laboratory results from GESUS were linked to information from national registers regarding morbidity and death. Cox proportional hazard regression was conducted with adjustment for age, sex, smoking status, haemoglobin......, leukocyte count, C-reactive protein and Charlson comorbidity index. RESULTS: We found a U-shaped relationship between mortality and platelet count. Mortality was significantly increased for platelet count 300×10(9)/L. When categorizing platelet count using the interval 201-250×10(9)/L...

  5. Laktaattimääritys kemian analysaattorilla ja verikaasuanalysaattorilla

    OpenAIRE

    Raatikainen, Jenni

    2015-01-01

    Normaalisti hapellisissa oloissa glukoosi hajoaa aineenvaihdunnan seurauksena solujen käyttöön vapautuvaksi energiaksi, vedeksi ja hiilidioksidiksi. Hapettomissa oloissa glukoosi kuitenkin hajoaa laktaatiksi. Sydämen, verenkierron tai keuhkojen vakava toimintahäiriö voi aiheuttaa kudosten vähentynyttä hapensaantia, joka voi johtaa anaerobiseen aineenvaihduntaan soluissa ja laktaatin muodostumiseen. Tämän vuoksi laktaatti on yleinen tutkimus esimerkiksi teho-osastolla. Laktaattia voi muodostua...

  6. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    Science.gov (United States)

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  7. Study on advancement of in vivo counting using mathematical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kinase, Sakae [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-05-01

    To obtain an assessment of the committed effective dose, individual monitoring for the estimation of intakes of radionuclides is required. For individual monitoring of exposure to intakes of radionuclides, direct measurement of radionuclides in the body - in vivo counting- is very useful. To advance in a precision in vivo counting which fulfills the requirements of ICRP 1990 recommendations, some problems, such as the investigation of uncertainties in estimates of body burdens by in vivo counting, and the selection of the way to improve the precision, have been studied. In the present study, a calibration technique for in vivo counting application using Monte Carlo simulation was developed. The advantage of the technique is that counting efficiency can be obtained for various shapes and sizes that are very difficult to change for phantoms. To validate the calibration technique, the response functions and counting efficiencies of a whole-body counter installed in JAERI were evaluated using the simulation and measurements. Consequently, the calculations are in good agreement with the measurements. The method for the determination of counting efficiency curves as a function of energy was developed using the present technique and a physiques correction equation was derived from the relationship between parameters of correction factor and counting efficiencies of the JAERI whole-body counter. The uncertainties in body burdens of {sup 137}Cs estimated with the JAERI whole-body counter were also investigated using the Monte Carlo simulation and measurements. It was found that the uncertainties of body burdens estimated with the whole-body counter are strongly dependent on various sources of uncertainty such as radioactivity distribution within the body and counting statistics. Furthermore, the evaluation method of the peak efficiencies of a Ge semi-conductor detector was developed by Monte Carlo simulation for optimum arrangement of Ge semi-conductor detectors for

  8. Quantitative Evaluation of Segmentation- and Atlas-Based Attenuation Correction for PET/MR on Pediatric Patients.

    Science.gov (United States)

    Bezrukov, Ilja; Schmidt, Holger; Gatidis, Sergios; Mantlik, Frédéric; Schäfer, Jürgen F; Schwenzer, Nina; Pichler, Bernd J

    2015-07-01

    Pediatric imaging is regarded as a key application for combined PET/MR imaging systems. Because existing MR-based attenuation-correction methods were not designed specifically for pediatric patients, we assessed the impact of 2 potentially influential factors: inter- and intrapatient variability of attenuation coefficients and anatomic variability. Furthermore, we evaluated the quantification accuracy of 3 methods for MR-based attenuation correction without (SEGbase) and with bone prediction using an adult and a pediatric atlas (SEGwBONEad and SEGwBONEpe, respectively) on PET data of pediatric patients. The variability of attenuation coefficients between and within pediatric (5-17 y, n = 17) and adult (27-66 y, n = 16) patient collectives was assessed on volumes of interest (VOIs) in CT datasets for different tissue types. Anatomic variability was assessed on SEGwBONEad/pe attenuation maps by computing mean differences to CT-based attenuation maps for regions of bone tissue, lungs, and soft tissue. PET quantification was evaluated on VOIs with physiologic uptake and on 80% isocontour VOIs with elevated uptake in the thorax and abdomen/pelvis. Inter- and intrapatient variability of the bias was assessed for each VOI group and method. Statistically significant differences in mean VOI Hounsfield unit values and linear attenuation coefficients between adult and pediatric collectives were found in the lungs and femur. The prediction of attenuation maps using the pediatric atlas showed a reduced error in bone tissue and better delineation of bone structure. Evaluation of PET quantification accuracy showed statistically significant mean errors in mean standardized uptake values of -14% ± 5% and -23% ± 6% in bone marrow and femur-adjacent VOIs with physiologic uptake for SEGbase, which could be reduced to 0% ± 4% and -1% ± 5% using SEGwBONEpe attenuation maps. Bias in soft-tissue VOIs was less than 5% for all methods. Lung VOIs showed high SDs in the range of 15% for

  9. Differences in meristic counts of the genus Clarias (pisces: clariidae ...

    African Journals Online (AJOL)

    Specific differences in meristic counts were exhibited in both the anal fin ray count and the vertebral count in the clariids of Anambra rver, Nigeria. There was a close numerical relationship between the number of anal fin rays and the number of vertebrae. The present study further justifies the taxonomic importance of anal fin ...

  10. Validation of an automated colony counting system for group A Streptococcus.

    Science.gov (United States)

    Frost, H R; Tsoi, S K; Baker, C A; Laho, D; Sanderson-Smith, M L; Steer, A C; Smeesters, P R

    2016-02-08

    The practice of counting bacterial colony forming units on agar plates has long been used as a method to estimate the concentration of live bacteria in culture. However, due to the laborious and potentially error prone nature of this measurement technique, an alternative method is desirable. Recent technologic advancements have facilitated the development of automated colony counting systems, which reduce errors introduced during the manual counting process and recording of information. An additional benefit is the significant reduction in time taken to analyse colony counting data. Whilst automated counting procedures have been validated for a number of microorganisms, the process has not been successful for all bacteria due to the requirement for a relatively high contrast between bacterial colonies and growth medium. The purpose of this study was to validate an automated counting system for use with group A Streptococcus (GAS). Twenty-one different GAS strains, representative of major emm-types, were selected for assessment. In order to introduce the required contrast for automated counting, 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) dye was added to Todd-Hewitt broth with yeast extract (THY) agar. Growth on THY agar with TTC was compared with growth on blood agar and THY agar to ensure the dye was not detrimental to bacterial growth. Automated colony counts using a ProtoCOL 3 instrument were compared with manual counting to confirm accuracy over the stages of the growth cycle (latent, mid-log and stationary phases) and in a number of different assays. The average percentage differences between plating and counting methods were analysed using the Bland-Altman method. A percentage difference of ±10 % was determined as the cut-off for a critical difference between plating and counting methods. All strains measured had an average difference of less than 10 % when plated on THY agar with TTC. This consistency was also observed over all phases of the growth

  11. Statistical tests to compare motif count exceptionalities

    Directory of Open Access Journals (Sweden)

    Vandewalle Vincent

    2007-03-01

    Full Text Available Abstract Background Finding over- or under-represented motifs in biological sequences is now a common task in genomics. Thanks to p-value calculation for motif counts, exceptional motifs are identified and represent candidate functional motifs. The present work addresses the related question of comparing the exceptionality of one motif in two different sequences. Just comparing the motif count p-values in each sequence is indeed not sufficient to decide if this motif is significantly more exceptional in one sequence compared to the other one. A statistical test is required. Results We develop and analyze two statistical tests, an exact binomial one and an asymptotic likelihood ratio test, to decide whether the exceptionality of a given motif is equivalent or significantly different in two sequences of interest. For that purpose, motif occurrences are modeled by Poisson processes, with a special care for overlapping motifs. Both tests can take the sequence compositions into account. As an illustration, we compare the octamer exceptionalities in the Escherichia coli K-12 backbone versus variable strain-specific loops. Conclusion The exact binomial test is particularly adapted for small counts. For large counts, we advise to use the likelihood ratio test which is asymptotic but strongly correlated with the exact binomial test and very simple to use.

  12. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  13. Sperm motility and morphology as changing parameters linked to sperm count variations.

    Directory of Open Access Journals (Sweden)

    Dua A

    1996-10-01

    Full Text Available Variations in semen analyses of 177 males over a 1 year period were assessed. The average means of total counts, motility, morphology, total motile count and non-motile % were determined for 5 classes of patients ranging from azoospermic to normospermic. Positive relationships between a falling sperm count, a decrease in motility and total motile counts were seen. Also, increasingly, abnormal forms were found with lower sperm counts.

  14. CalCOFI Larvae Counts, Scientific Names CI to CO

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  15. CalCOFI Larvae Counts, Scientific Names DH to EC

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  16. CalCOFI Larvae Counts, Scientific Names TF to U

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  17. CalCOFI Larvae Counts, Scientific Names HJ to ID

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  18. CalCOFI Larvae Counts, Scientific Names AN to AR

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  19. CalCOFI Larvae Counts, Scientific Names SJ to ST

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  20. CalCOFI Larvae Counts, Scientific Names CP to DE

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  1. CalCOFI Larvae Counts, Scientific Names C to CE

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  2. CalCOFI Larvae Counts, Scientific Names EV to GN

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  3. CalCOFI Larvae Counts, Scientific Names V to Z

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  4. CalCOFI Larvae Counts, Scientific Names ED to EU

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  5. CalCOFI Larvae Counts, Scientific Names SD to SI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  6. CalCOFI Larvae Counts, Scientific Names MB to MO

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  7. CalCOFI Larvae Counts, Scientific Names LJ to MA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  8. CalCOFI Larvae Counts, Scientific Names AS to BA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  9. CalCOFI Larvae Counts, Scientific Names SB to SC

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  10. CalCOFI Larvae Counts, Scientific Names MP to NA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  11. CalCOFI Larvae Counts, Scientific Names SU to TE

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  12. CalCOFI Larvae Counts, Scientific Names PL to PO

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  13. CalCOFI Larvae Counts, Scientific Names IE to LA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  14. CalCOFI Larvae Counts, Scientific Names A to AM

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  15. CalCOFI Larvae Counts, Scientific Names HB to HI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  16. CalCOFI Larvae Counts, Scientific Names OM to OX

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  17. CalCOFI Larvae Counts, Scientific Names Q to SA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  18. CalCOFI Larvae Counts, Scientific Names PP to PZ

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  19. CalCOFI Larvae Counts, Scientific Names GO to HA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  20. CalCOFI Larvae Counts, Scientific Names NB to OL

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  1. CalCOFI Larvae Counts, Scientific Names LB to LI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  2. CalCOFI Larvae Counts, Scientific Names BCE to BZ

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  3. CalCOFI Larvae Counts, Scientific Names CD to CH

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  4. CalCOFI Larvae Counts, Scientific Names OY to PI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  5. Point Count Length and Detection of Forest Neotropical Migrant Birds

    Science.gov (United States)

    Deanna K. Dawson; David R. Smith; Chandler S. Robbins

    1995-01-01

    Comparisons of bird abundances among years or among habitats assume that the rates at which birds are detected and counted are constant within species. We use point count data collected in forests of the Mid-Atlantic states to estimate detection probabilities for Neotropical migrant bird species as a function of count length. For some species, significant differences...

  6. Men of physics Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    2013-01-01

    Men of Physics: Benjamin Thompson—Count Rumford: Count Rumford on the Nature of Heat presents the life and works of Count Rumford, an American-born British physicist and inventor. This book is divided in two parts. The first part gives a biographical sketch of Count Rumford, Benjamin Thompson, who was born on March 23, 1753 and died in 1814. This part also discusses the contemporary caloric theory and the reason why Rumford disbelieved the theory. The second part presents his technical works, discoveries, and contributions in the field of physics. Some of which are his demonstration of the e

  7. Quality control of radiation counting systems and measurement of minimum detectable activity

    International Nuclear Information System (INIS)

    Song, Byoung Chul; Han, Sung Sim; Kim, Young Bok; Jee, Kwang Yong; Sohn, Se Chul

    2004-01-01

    Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the γ-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 dps within 20 confidence levels. The average alpha background level for the low background α/β counting system was 0.31 cpm and the efficiency for alpha counting was 34.38 %. The average beta background level for the α/β counting system was 1.30 cpm and the efficiency for beta counting was 46.5%. The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the γ-spectrometer was found to be 3.2 Bq/mL and 3.8 Bq/mL for the liquid scintillation counter, and 20.5 and 23.0 Bq/mL, respectively for the α and β counting system

  8. Analysis of spatial count data using Kalman smoothing

    DEFF Research Database (Denmark)

    Dethlefsen, Claus

    2007-01-01

    We consider spatial count data from an agricultural field experiment. Counts of weed plants in a field have been recorded in a project on precision farming. Interest is in mapping the weed intensity so that the dose of herbicide applied at any location can be adjusted to the amount of weed present...

  9. Another Crisis Can We Count on the Reserves?

    Science.gov (United States)

    1994-05-16

    the " marshmallow " of volunteerism is something that is too soft of a concept to be counted upon. It only makes sense to develop a more well-defined...unrealistic. Involuntary activation has proven to be a hollow concept in practice, and planners are reluctant to count on the " marshmallow " of

  10. Estimating spatial and temporal components of variation in count data using negative binomial mixed models

    Science.gov (United States)

    Irwin, Brian J.; Wagner, Tyler; Bence, James R.; Kepler, Megan V.; Liu, Weihai; Hayes, Daniel B.

    2013-01-01

    Partitioning total variability into its component temporal and spatial sources is a powerful way to better understand time series and elucidate trends. The data available for such analyses of fish and other populations are usually nonnegative integer counts of the number of organisms, often dominated by many low values with few observations of relatively high abundance. These characteristics are not well approximated by the Gaussian distribution. We present a detailed description of a negative binomial mixed-model framework that can be used to model count data and quantify temporal and spatial variability. We applied these models to data from four fishery-independent surveys of Walleyes Sander vitreus across the Great Lakes basin. Specifically, we fitted models to gill-net catches from Wisconsin waters of Lake Superior; Oneida Lake, New York; Saginaw Bay in Lake Huron, Michigan; and Ohio waters of Lake Erie. These long-term monitoring surveys varied in overall sampling intensity, the total catch of Walleyes, and the proportion of zero catches. Parameter estimation included the negative binomial scaling parameter, and we quantified the random effects as the variations among gill-net sampling sites, the variations among sampled years, and site × year interactions. This framework (i.e., the application of a mixed model appropriate for count data in a variance-partitioning context) represents a flexible approach that has implications for monitoring programs (e.g., trend detection) and for examining the potential of individual variance components to serve as response metrics to large-scale anthropogenic perturbations or ecological changes.

  11. Material screening with HPGe counting station for PandaX experiment

    International Nuclear Information System (INIS)

    Wang, X.; Chen, X.; Fu, C.; Ji, X.; Liu, X.; Xie, P.; Zhang, T.; Mao, Y.; Wang, S.; Wang, H.

    2016-01-01

    A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min within the energy range of 20 to 2700 keV is achieved due to the well-designed passive shield. The sentivities of the HPGe detetector reach mBq/kg level for isotopes like K, U, Th, and even better for Co and Cs, resulted from the low-background rate and the high relative detection efficiency of 175%. The structure and performance of the counting station are described in this article. Detailed counting results for the radioactivity in materials used by the PandaX dark-matter experiment are presented. The upgrading plan of the counting station is also discussed.

  12. Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Chao-Jen, E-mail: cjlai3711@gmail.com; Zhong, Yuncheng; Yi, Ying; Wang, Tianpeng; Shaw, Chris C. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2015-06-15

    Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical

  13. Theory of photoelectron counting statistics

    International Nuclear Information System (INIS)

    Blake, J.

    1980-01-01

    The purpose of the present essay is to provide a detailed analysis of those theoretical aspects of photoelectron counting which are capable of experimental verification. Most of our interest is in the physical phenomena themselves, while part is in the mathematical techniques. Many of the mathematical methods used in the analysis of the photoelectron counting problem are generally unfamiliar to physicists interested in the subject. For this reason we have developed the essay in such a fashion that, although primary interest is focused on the physical phenomena, we have also taken pains to carry out enough of the analysis so that the reader can follow the main details. We have chosen to present a consistently quantum mechanical version of the subject, in that we follow the Glauber theory throughout. (orig./WL)

  14. Liquid scintillation counting system with automatic gain correction

    International Nuclear Information System (INIS)

    Frank, R.B.

    1976-01-01

    An automatic liquid scintillation counting apparatus is described including a scintillating medium in the elevator ram of the sample changing apparatus. An appropriate source of radiation, which may be the external source for standardizing samples, produces reference scintillations in the scintillating medium which may be used for correction of the gain of the counting system

  15. Exponential Martingales and Changes of Measure for Counting Processes

    DEFF Research Database (Denmark)

    Sokol, Alexander; Hansen, Niels Richard

    2015-01-01

    We give sufficient criteria for the Doléans-Dade exponential of a stochastic integral with respect to a counting process local martingale to be a true martingale. The criteria are adapted particularly to the case of counting processes and are sufficiently weak to be useful and verifiable, as we i...... illustrate by several examples. In particular, the criteria allow for the construction of for example nonexplosive Hawkes processes, counting processes with stochastic intensities depending on diffusion processes as well as inhomogeneous finite-state Markov processes....

  16. Fast sequential Monte Carlo methods for counting and optimization

    CERN Document Server

    Rubinstein, Reuven Y; Vaisman, Radislav

    2013-01-01

    A comprehensive account of the theory and application of Monte Carlo methods Based on years of research in efficient Monte Carlo methods for estimation of rare-event probabilities, counting problems, and combinatorial optimization, Fast Sequential Monte Carlo Methods for Counting and Optimization is a complete illustration of fast sequential Monte Carlo techniques. The book provides an accessible overview of current work in the field of Monte Carlo methods, specifically sequential Monte Carlo techniques, for solving abstract counting and optimization problems. Written by authorities in the

  17. Application of neutron multiplicity counting to waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Ensslin, N. [Los Alamos National Lab., NM (United States); Sharpe, T.J. [North Carolina State Univ., Raleigh, NC (United States)

    1997-11-01

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A {open_quotes}tunable multiplicity{close_quotes} approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions. 9 refs., 6 figs.

  18. Counting statistics and loss corrections for the APS

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.M.

    1992-01-01

    It has been suggested that for timing experiments, it might be advantageous to arrange the bunches in the storage ring in an asymmetrical mode. In this paper, we determine the counting losses from pulsed x-ray sources from basic probabilistic arguments and from Poisson statistics. In particular the impact on single photon counting losses of a variety of possible filling modes for the Advanced Photon Source (APS) is examined. For bunches of equal current, a loss of 10% occurs whenever the count rate exceeds 21% of the bunch repetition rate. This changes slightly when bunches containing unequal numbers of particles are considered. The results are applied to several common detector/electronics systems

  19. Counting statistics and loss corrections for the APS

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.M.

    1992-01-01

    It has been suggested that for timing experiments, it might be advantageous to arrange the bunches in the storage ring in an asymmetrical mode. In this paper, we determine the counting losses from pulsed x-ray sources from basic probabilistic arguments and from Poisson statistics. In particular the impact on single-photon counting losses of a variety of possible filling modes for the Advanced Photon Source (APS) is examined. For bunches of equal current, a loss of 10% occurs whenever the count rate exceeds 21% of the bunch repetition rate. This changes slightly when bunches containing unequal numbers of particles are considered. The results are applied to several common detector/electronics systems

  20. Accuracy and precision in activation analysis: counting

    International Nuclear Information System (INIS)

    Becker, D.A.

    1974-01-01

    Accuracy and precision in activation analysis was investigated with regard to counting of induced radioactivity. The various parameters discussed include configuration, positioning, density, homogeneity, intensity, radioisotopic purity, peak integration, and nuclear constants. Experimental results are presented for many of these parameters. The results obtained indicate that counting errors often contribute significantly to the inaccuracy and imprecision of analyses. The magnitude of these errors range from less than 1 percent to 10 percent or more in many cases

  1. Remote system for counting of nuclear pulses

    International Nuclear Information System (INIS)

    Nieves V, J.A.; Garcia H, J.M.; Aguilar B, M.A.

    1999-01-01

    In this work, it is describe technically the remote system for counting of nuclear pulses, an integral system of the project radiological monitoring in a petroleum distillation tower. The system acquires the counting of incident nuclear particles in a nuclear detector which process this information and send it in serial form, using the RS-485 toward a remote receiver, which can be a Personal computer or any other device capable to interpret the communication protocol. (Author)

  2. Pancreas segmentation from 3D abdominal CT images using patient-specific weighted subspatial probabilistic atlases

    Science.gov (United States)

    Karasawa, Kenichi; Oda, Masahiro; Hayashi, Yuichiro; Nimura, Yukitaka; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Rueckert, Daniel; Mori, Kensaku

    2015-03-01

    Abdominal organ segmentations from CT volumes are now widely used in the computer-aided diagnosis and surgery assistance systems. Among abdominal organs, the pancreas is especially difficult to segment because of its large individual differences of the shape and position. In this paper, we propose a new pancreas segmentation method from 3D abdominal CT volumes using patient-specific weighted-subspatial probabilistic atlases. First of all, we perform normalization of organ shapes in training volumes and an input volume. We extract the Volume Of Interest (VOI) of the pancreas from the training volumes and an input volume. We divide each training VOI and input VOI into some cubic regions. We use a nonrigid registration method to register these cubic regions of the training VOI to corresponding regions of the input VOI. Based on the registration results, we calculate similarities between each cubic region of the training VOI and corresponding region of the input VOI. We select cubic regions of training volumes having the top N similarities in each cubic region. We subspatially construct probabilistic atlases weighted by the similarities in each cubic region. After integrating these probabilistic atlases in cubic regions into one, we perform a rough-to-precise segmentation of the pancreas using the atlas. The results of the experiments showed that utilization of the training volumes having the top N similarities in each cubic region led good results of the pancreas segmentation. The Jaccard Index and the average surface distance of the result were 58.9% and 2.04mm on average, respectively.

  3. Eosinophil count is positively correlated with coronary artery calcification

    International Nuclear Information System (INIS)

    Tanaka, Muhei; Fukui, Michiaki; Yamasaki, Masahiro; Hasegawa, Goji; Oda, Yohei; Nakamura, Naoto; Tomiyasu, Ki-ichiro; Akabame, Satoshi; Nakano, Koji

    2012-01-01

    Recent studies suggested that allergic disorders and increased eosinophil count were associated with atherosclerosis. The purpose of this study was to assess the relationship between eosinophil count and coronary artery calcification (CAC). We performed a cross-sectional study in 1363 consecutive participants with clinical suspicion of coronary heart disease (CHD). We evaluated the relationships between CAC score determined by multislice CT and peripheral eosinophil count as well as major cardiovascular risk factors, including age, body mass index, smoking status, hypertension, dyslipidemia, diabetes mellitus (DM), high-sensitivity C-reactive protein and estimated glomerular filtration rate (eGFR). Sex (P=0.0004), hypertension (P=0.0002), dyslipidemia (P=0.0004) and DM (P=0.0061) were associated with log (CAC+1), respectively. Positive correlations were found between log (CAC+1), and age (r=0.325, P<0.0001) and eosinophil count (r=0.165, P<0.0001). Negative correlations were found between log (CAC+1) and eGFR (r=-0.166, P<0.0001). Multivariate linear regression analysis demonstrated that age (β=0.314, P<0.0001), sex (β=0.124, P<0.0001), hypertension (β=0.084, P=0.0008), DM (β=0.108, P<0.0001), eGFR (β=-0.079, P=0.0021) and eosinophil count (β=0.147, P<0.0001) were independent determinants of log (CAC+1). In conclusion, eosinophil count correlated positively with CAC in participants with clinical suspicion of CHD. (author)

  4. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  5. Platelet Counts, MPV and PDW in Culture Proven and Probable Neonatal Sepsis and Association of Platelet Counts with Mortality Rate

    International Nuclear Information System (INIS)

    Ahmad, M. S.; Waheed, A.

    2014-01-01

    Objective: To determine frequency of thrombocytopenia and thrombocytosis, the MPV (mean platelet volume) and PDW (platelet distribution width) in patients with probable and culture proven neonatal sepsis and determine any association between platelet counts and mortality rate. Study Design: Descriptive analytical study. Place and Duration of Study: NICU, Fazle Omar Hospital, from January 2011 to December 2012. Methodology: Cases of culture proven and probable neonatal sepsis, admitted in Fazle Omar Hospital, Rabwah, were included in the study. Platelet counts, MPV and PDW of the cases were recorded. Mortality was documented. Frequencies of thrombocytopenia ( 450000/mm3) were ascertained. Mortality rates in different groups according to platelet counts were calculated and compared by chi-square test to check association. Results: Four hundred and sixty nine patients were included; 68 (14.5%) of them died. One hundred and thirty six (29%) had culture proven sepsis, and 333 (71%) were categorized as probable sepsis. Thrombocytopenia was present in 116 (24.7%), and thrombocytosis was present in 36 (7.7%) cases. Median platelet count was 213.0/mm3. Twenty eight (27.7%) patients with thrombocytopenia, and 40 (12.1%) cases with normal or raised platelet counts died (p < 0.001). Median MPV was 9.30, and median PDW was 12.30. MPV and PDW of the patients who died and who were discharged were not significantly different from each other. Conclusion: Thrombocytopenia is a common complication of neonatal sepsis. Those with thrombocytopenia have higher mortality rate. No significant difference was present between PDW and MPV of the cases who survived and died. (author)

  6. Health Behavior Theory in Popular Calorie Counting Apps: A Content Analysis

    OpenAIRE

    Davis, Siena F; Ellsworth, Marisa A; Payne, Hannah E; Hall, Shelby M; West, Joshua H; Nordhagen, Amber L

    2016-01-01

    Background Although the Health & Fitness category of the Apple App Store features hundreds of calorie counting apps, the extent to which popular calorie counting apps include health behavior theory is unknown. Objective This study evaluates the presence of health behavior theory in calorie counting apps. Methods Data for this study came from an extensive content analysis of the 10 most popular calorie counting apps in the Health & Fitness category of the Apple App Store. Results Each app was ...

  7. Problems and precision of the alpha scintillation radon counting system

    International Nuclear Information System (INIS)

    Lucas, H.F.; Markuu, F.

    1985-01-01

    Variations in efficiency as large as 3% have been found for radon scintillation counting systems in which the photomultiplier tubes are sensitive to the thermoluminescent photons emitted by the scintillator after exposure to light or for which the resolution has deteriorated. The additional standard deviation caused by counting a radon chamber on multiple counting systems has been evaluated and the effect, if present, did not exceed about 0.1%. The chambers have been calibrated for the measurement of radon in air, and the standard deviation was equal to statistical counting error combined with a systematic error of 1.1%. 3 references, 2 figures, 2 tables

  8. Daily variability of strongyle fecal egg counts in horses

    DEFF Research Database (Denmark)

    Carstensen, Helena; Larsen, Lene; Ritz, Christian

    2013-01-01

    Strongyle parasites are ubiquitous in grazing horses and constitute a potential threat to equine health. Feces were collected from six horses four times daily over a period of 5 days. Fecal egg counts (FECs) were performed to identify any diurnal rhythms in strongyle egg shedding and to quantify...... variability at the different levels: individual horses, repeated counts, repeated subsamples, different time points, and different days. No significant differences in FECs were found between the different time points (P = .11). The variables-horse, day, subsample, and egg count-accounted for a variance of 104...... subsamples and repeated egg counts on the same subsamples, whereas the variability of FECs between following days can be considered negligible. The findings of this study have implication for designing and performing field surveillance of strongyle FEC levels and applying the FEC reduction test...

  9. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  10. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  11. Application of PSD for low level alpha counting using liquid scintillation counting

    International Nuclear Information System (INIS)

    Krishnamachari, G.; Vaze, P.K.; Iyer, M.R.

    1989-01-01

    In the liquid scintillator the light produced by alpha particles decays differently than those produced by electrons. Pulse shape discrimination (PSD) methods are employed to estimate low levels of alpha emitting radionuclides by reducing the background due to either beta or gamma events. An attempt is being made to develop a liquid scintillation counting sytem using a simple PSD circuit to achieve a background of 0.01 counts/min. The PSD circuit is based on measuring zero cross over points to differentiate particle types. The input signal is first differentiated by a delay line and subsequently by a RC circuit. The width of the initial part of the doubly differentiated pulse is different for alpha and beta pulses. This width is converted to amplitude by a time-to-amplitude converter (TAC). The higher amplitude pulses from the TAC are due to alpha particles and they are separated by an integral discriminator. The output from the integral discriminator opens a linear gate to record the pulse height spectrum. The figure of merit of the PSD circuit and background in the alpha energy channel have been worked out using different scintillator types. (author). 4 figs

  12. Is total lymphocyte count related to nutritional markers in hospitalized older adults?

    Directory of Open Access Journals (Sweden)

    Vânia Aparecida LEANDRO-MERHI

    Full Text Available ABSTRACT BACKGROUND Older patients are commonly malnourished during hospital stay, and a high prevalence of malnutrition is found in hospitalized patients aged more than 65 years. OBJECTIVE To investigate whether total lymphocyte count is related to other nutritional markers in hospitalized older adults. METHODS Hospitalized older adults (N=131 were recruited for a cross-sectional study. Their nutritional status was assessed by the Nutritional Risk Screening (NRS, anthropometry, and total lymphocyte count. The statistical analyses included the chi-square test, Fisher's exact test, and Mann-Whitney test. Spearman's linear correlation coefficient determined whether total lymphocyte count was correlated with the nutritional markers. Multiple linear regression determined the parameters associated with lymphocyte count. The significance level was set at 5%. RESULTS According to the NRS, 41.2% of the patients were at nutritional risk, and 36% had mild or moderate depletion according to total lymphocyte count. Total lymphocyte count was weakly correlated with mid-upper arm circumference (r=0.20507; triceps skinfold thickness (r=0.29036, and length of hospital stay (r= -0.21518. Total lymphocyte count in different NRS categories differed significantly: older adults who were not at nutritional risk had higher mean and median total lymphocyte count ( P =0.0245. Multiple regression analysis showed that higher lymphocyte counts were associated with higher triceps skinfold thicknesses and no nutritional risk according to the NRS. CONCLUSION Total lymphocyte count was correlated with mid-upper arm circumference, triceps skinfold thickness, and nutritional risk according to the NRS. In multiple regression the combined factors that remained associated with lymphocyte count were NRS and triceps skinfold thickness. Therefore, total lymphocyte count may be considered a nutritional marker. Other studies should confirm these findings.

  13. Effect of strategic deworming of village cattle in Uganda with moxidectin pour-on on faecal egg count and pasture larval counts : short communication

    Directory of Open Access Journals (Sweden)

    J.W. Magona

    2004-06-01

    Full Text Available Strategic application of moxidectin pour-on (Cydectin(R was evaluated in Uganda for its effect on pasture larval counts and gastrointestinal nematode faecal egg counts in village cattle kept under tethering (semi-intensive grazing management. The strategic deworming schedule involved treating cattle twice at an interval of 2 months, at the end of the 1st wet season and during the 2nd wet season. Two groups of 30 cattle, each consisting of a treated and a control group, were examined for nematode infections every 4 weeks from June 1999 to January 2000. The treated group had significantly lower mean faecal egg counts than the untreated groups (t-value = 2.47, P < 0.05. Generally, the pasture larval counts on treated farms were lower than on untreated ones, but not significantly so (t-value = 2.22, P = 0.068. Pasture larval counts with different nematode species on treated farms were lower than on untreated ones, but the differences were not significant for Haemonchus spp. (t-value=1.68, P=0.145, Oesophagostomum spp. (t-value= 1.87, P=0.111, Trichostrongylus spp. (t-value=1.93, P=0.102, Dictyocaulus spp. (t-value= -0.74, P=0.485 and Cooperia spp. (t-value=-1.00, P=0.356. Treated farms did , however, have significantly lower pasture larval counts of Bunostomum spp. (t-value=4.64, P<0.05. This study has revealed that the application ofmoxidectin pour-on on cattle has an effect on faecal egg count and pasture contamination under the tethering grazing system. Moxidectin pour-on and the strategic deworming schedule evaluated here could be used for the control of gastrointestinal nematode infections in cattle by small-scale farmers who practise tethering or semi-intensive grazing management in Uganda and other tropical countries, especially where there is a bimodal rainfall pattern.

  14. Agreement of manual cell counts and automated counts of the scil Vet abc Plus(+) hematology analyzer for analysis of equine synovial fluid.

    Science.gov (United States)

    Van de Water, Eline; Oosterlinck, Maarten; Duchateau, Luc; Pille, Frederik

    2016-06-01

    The purpose of this study was to determine whether the scil Vet abc Plus(+) (SCIL Animal Care Company, Altorf, France), an impedance hematology analyzer, can accurately quantify and differentiate nucleated blood cells (NBCs) in equine synovial fluid. Synovial fluid samples (n=242) in different stages of experimentally induced inflammation were analyzed with and without hyaluronidase pretreatment and compared to manual hemocytometer counts and smear reviews. No significant effect of hyaluronidase pretreatment was observed. Total nucleated cell counts of the scil Vet abc Plus(+) were significantly higher compared to the manual method (P=0.02), yet the difference was small and clinically irrelevant (ratio manual/automated count equal to 0.97 with 95% CI [0.95, 1.00]). Differential cell counts of the scil Vet abc Plus(+) were not accurate. In conclusion, the scil Vet abc Plus(+) hematology analyzer is highly accurate for quantification, but not accurate for differentiation of NBCs in equine synovial fluid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. How to count an introduction to combinatorics

    CERN Document Server

    Allenby, RBJT

    2010-01-01

    What's It All About? What Is Combinatorics? Classic Problems What You Need to Know Are You Sitting Comfortably? Permutations and Combinations The Combinatorial Approach Permutations CombinationsApplications to Probability Problems The Multinomial Theorem Permutations and Cycles Occupancy Problems Counting the Solutions of Equations New Problems from Old A ""Reduction"" Theorem for the Stirling Numbers The Inclusion-Exclusion Principle Double Counting Derangements A Formula for the Stirling NumbersStirling and Catalan Numbers Stirling Numbers Permutations and Stirling Numbers Catalan Numbers Pa

  16. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  17. Unaccounted Workload Factor: Game-Day Pitch Counts in High School Baseball Pitchers—An Observational Study

    Science.gov (United States)

    Zaremski, Jason L.; Zeppieri, Giorgio; Jones, Deborah L.; Tripp, Brady L.; Bruner, Michelle; Vincent, Heather K.; Horodyski, MaryBeth

    2018-01-01

    Background: Throwing injuries are common in high school baseball. Known risk factors include excessive pitch counts, year-round pitching, and pitching with arm pain and fatigue. Despite the evidence, the prevalence of pitching injuries among high school players has not decreased. One possibility to explain this pattern is that players accumulate unaccounted pitch volume during warm-up and bullpen activity, but this has not yet been examined. Hypotheses: Our primary hypothesis was that approximately 30% to 40% of pitches thrown off a mound by high school pitchers during a game-day outing are unaccounted for in current data but will be revealed when bullpen sessions and warm-up pitches are included. Our secondary hypothesis was that there is wide variability among players in the number of bullpen pitches thrown per outing. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Researchers counted all pitches thrown off a mound during varsity high school baseball games played by 34 high schools in North Central Florida during the 2017 season. Results: We recorded 13,769 total pitches during 115 varsity high school baseball starting pitcher outings. The mean ± SD pitch numbers per game were calculated for bullpen activity (27.2 ± 9.4), warm-up (23.6 ±8.0), live games (68.9 ±19.7), and total pitches per game (119.7 ± 27.8). Thus, 42.4% of the pitches performed were not accounted for in the pitch count monitoring of these players. The number of bullpen pitches thrown varied widely among players, with 25% of participants in our data set throwing fewer than 22 pitches and 25% throwing more than 33 pitches per outing. Conclusion: In high school baseball players, pitch count monitoring does not account for the substantial volume of pitching that occurs during warm-up and bullpen activity during the playing season. These extra pitches should be closely monitored to help mitigate the risk of overuse injury. PMID:29662911

  18. Unaccounted Workload Factor: Game-Day Pitch Counts in High School Baseball Pitchers-An Observational Study.

    Science.gov (United States)

    Zaremski, Jason L; Zeppieri, Giorgio; Jones, Deborah L; Tripp, Brady L; Bruner, Michelle; Vincent, Heather K; Horodyski, MaryBeth

    2018-04-01

    Throwing injuries are common in high school baseball. Known risk factors include excessive pitch counts, year-round pitching, and pitching with arm pain and fatigue. Despite the evidence, the prevalence of pitching injuries among high school players has not decreased. One possibility to explain this pattern is that players accumulate unaccounted pitch volume during warm-up and bullpen activity, but this has not yet been examined. Our primary hypothesis was that approximately 30% to 40% of pitches thrown off a mound by high school pitchers during a game-day outing are unaccounted for in current data but will be revealed when bullpen sessions and warm-up pitches are included. Our secondary hypothesis was that there is wide variability among players in the number of bullpen pitches thrown per outing. Cross-sectional study; Level of evidence, 3. Researchers counted all pitches thrown off a mound during varsity high school baseball games played by 34 high schools in North Central Florida during the 2017 season. We recorded 13,769 total pitches during 115 varsity high school baseball starting pitcher outings. The mean ± SD pitch numbers per game were calculated for bullpen activity (27.2 ± 9.4), warm-up (23.6 ±8.0), live games (68.9 ±19.7), and total pitches per game (119.7 ± 27.8). Thus, 42.4% of the pitches performed were not accounted for in the pitch count monitoring of these players. The number of bullpen pitches thrown varied widely among players, with 25% of participants in our data set throwing fewer than 22 pitches and 25% throwing more than 33 pitches per outing. In high school baseball players, pitch count monitoring does not account for the substantial volume of pitching that occurs during warm-up and bullpen activity during the playing season. These extra pitches should be closely monitored to help mitigate the risk of overuse injury.

  19. Optimizing the duration of point counts for monitoring trends in bird populations

    Science.gov (United States)

    Jared Verner

    1988-01-01

    Minute-by-minute analysis of point counts of birds in mixed-conifer forests in the Sierra National Forest, central California, showed that cumulative counts of species and individuals increased in a curvilinear fashion but did not reach asymptotes after 10 minutes of counting. Comparison of the expected number of individuals counted per hour with various combinations...

  20. Passive hand movements disrupt adults’ counting strategies

    Directory of Open Access Journals (Sweden)

    Ineke eImbo

    2011-09-01

    Full Text Available In the present study, we experimentally tested the role of hand motor circuits in simple-arithmetic strategies. Educated adults solved simple additions (e.g., 8+3 or simple subtractions (e.g., 11–3 while they were required to retrieve the answer from long-term memory (e.g., knowing that 8+3 = 11, to transform the problem by making an intermediate step (e.g., 8+3 = 8+2+1 = 10+1 = 11 or to count one-by-one (e.g., 8+3 = 8…9…10…11. During the process of solving the arithmetic problems, the experimenter did or did not move the participants’ hand on a 4-point matrix. The results show that passive hand movements disrupted the counting strategy while leaving the other strategies unaffected. This pattern of results is in agreement with a procedural account, showing that the involvement of hand motor circuits in adults’ mathematical abilities is reminiscent of finger counting during childhood.

  1. Count Nouns - Mass Nouns, Neat Nouns - Mess Nouns

    Directory of Open Access Journals (Sweden)

    Fred Landman

    2010-12-01

    Full Text Available In this paper I propose and formalize a theory of the mass-count distinction in which the denotations of count nouns are built from non-overlapping generators, while the denotations of mass nouns are built from overlapping generators. Counting is counting of generators, and it will follow that counting is only correct on count denotations. I will show that the theory allows two kinds of mass nouns: mess mass nouns with denotations built from overlapping minimal generators, and neat mass nouns with denotations built from overlapping generators, where the overlap is not located in the minimal generators. Prototypical mass nouns like meat and mud are of the first kind. I will argue that mass nouns like furniture and kitchenware are of the second type. I will discuss several phenomena—all involving one way or the other explicitly or implicitly individual classifiers like stuks in Dutch—that show that both distinctions mass/count and mess/neat are linguistically robust. I will show in particular that nouns like kitchenware pattern in various ways like count nouns, and not like mess mass nouns, and that these ways naturally involve the neat structure of their denotation. I will also show that they are real mass nouns: they can involve measures in the way mess mass nouns can and count nouns cannot. I will discuss grinding interpretations of count nouns, here rebaptized fission interpretations, and argue that these interpretations differ in crucial ways from the interpretations of lexical mass nouns. The paper will end with a foundational problem raised by fission interpretations, and in the course of this, atomless interpretation domains will re-enter the scene through the back door.ReferencesBarner, D. & Snedeker, J. 2005. ‘Quantity judgements and individuation: evidence that mass nouns count’. Cognition 97: 41–66.http://dx.doi.org/10.1016/j.cognition.2004.06.009PMid:16139586Bunt, H. 1985. Mass Terms and Model Theoretic Semantics. Cambridge

  2. Soil Characteristics, Microbial Compostion of Plot, Leaf Count and ...

    African Journals Online (AJOL)

    Soil Characteristics, Microbial Compostion of Plot, Leaf Count and Sprout Studies of Cocoyam ( Colocasia [Schott] and Xanthosoma [Schott], Araceae) Collected in Edo State, ... Science, Technology and Arts Research Journal ... Government Areas (LGA) in Edo state and describe them based on leaf count and sprout

  3. Step-count guidelines referenced on 60-minutes of moderate/vigorous physical activity

    Directory of Open Access Journals (Sweden)

    Fabio Eduardo Fontana

    2015-03-01

    Full Text Available The purpose of this study was to establish step-count guidelines for sixth-grade students and assess the ability of step-counts to discriminate between students achieving and not achieving 60-minutes of moderate to vigorous physical activity daily. 201 sixth-grade students completed the study. They wore a pedometer and an accelerometer at the waist level for one full day. ROC curves were used to establish step-count guidelines and determine the diagnostic accuracy of step-counts. Sixth grade students need 12,118 steps/day to reach adequate daily levels of physical activity. The AUC indicated good diagnostic accuracy of step-counts. Suggested step-count guidelines can be a useful tool for identifying children who need to increase their daily levels of physical activity. The step-count cutoff proposed in this study is adequate for discriminating between sixth grade students reaching and not reaching recommended levels of physical activity.

  4. Bayesian approach in MN low dose of radiation counting

    International Nuclear Information System (INIS)

    Serna Berna, A.; Alcaraz, M.; Acevedo, C.; Navarro, J. L.; Alcanzar, M. D.; Canteras, M.

    2006-01-01

    The Micronucleus assay in lymphocytes is a well established technique for the assessment of genetic damage induced by ionizing radiation. Due to the presence of a natural background of MN the net MN is obtained by subtracting this value to the gross value. When very low doses of radiation are given the induced MN is close even lower than the predetermined background value. Furthermore, the damage distribution induced by the radiation follows a Poisson probability distribution. These two facts pose a difficult task to obtain the net counting rate in the exposed situations. It is possible to overcome this problem using a bayesian approach, in which the selection of a priori distributions for the background and net counting rate plays an important role. In the present work we make a detailed analysed using bayesian theory to infer the net counting rate in two different situations: a) when the background is known for an individual sample, using exact value value for the background and Jeffreys prior for the net counting rate, and b) when the background is not known and we make use of a population background distribution as background prior function and constant prior for the net counting rate. (Author)

  5. Drone-based Object Counting by Spatially Regularized Regional Proposal Network

    OpenAIRE

    Hsieh, Meng-Ru; Lin, Yen-Liang; Hsu, Winston H.

    2017-01-01

    Existing counting methods often adopt regression-based approaches and cannot precisely localize the target objects, which hinders the further analysis (e.g., high-level understanding and fine-grained classification). In addition, most of prior work mainly focus on counting objects in static environments with fixed cameras. Motivated by the advent of unmanned flying vehicles (i.e., drones), we are interested in detecting and counting objects in such dynamic environments. We propose Layout Prop...

  6. Relationship between salivary flow rates and Candida counts in subjects with xerostomia.

    Science.gov (United States)

    Torres, Sandra R; Peixoto, Camila Bernardo; Caldas, Daniele Manhães; Silva, Eline Barboza; Akiti, Tiyomi; Nucci, Márcio; de Uzeda, Milton

    2002-02-01

    This study evaluated the relationship between salivary flow and Candida colony counts in the saliva of patients with xerostomia. Sialometry and Candida colony-forming unit (CFU) counts were taken from 112 subjects who reported xerostomia in a questionnaire. Chewing-stimulated whole saliva was collected and streaked in Candida plates and counted in 72 hours. Species identification was accomplished under standard methods. There was a significant inverse relationship between salivary flow and Candida CFU counts (P =.007) when subjects with high colony counts were analyzed (cutoff point of 400 or greater CFU/mL). In addition, the median sialometry of men was significantly greater than that of women (P =.003), even after controlling for confounding variables like underlying disease and medications. Sjögren's syndrome was associated with low salivary flow rate (P =.007). There was no relationship between the median Candida CFU counts and gender or age. There was a high frequency (28%) of mixed colonization. Candida albicans was the most frequent species, followed by C parapsilosis, C tropicalis, and C krusei. In subjects with high Candida CFU counts there was an inverse relationship between salivary flow and Candida CFU counts.

  7. Operation voltage of the counting system of nuclear traces in solids

    International Nuclear Information System (INIS)

    Garcia, M.L.; Quirino, L.L.; Mireles, F.; Davila, J.I.; Pinedo, J.L.; Lugo, J.F.; Vadillo, V.E.

    2002-01-01

    The semi-automatic counting system based on electric spark and used for traces reading in solid state detectors is evaluated for obtaining its counting voltage and also the breaking voltage of material. In the treatment of the solid state detectors it is continued the NTD methodology for concluding with the individual counting of the films, whose graphics offer the existing relationship among the applied voltage and the traces number. From each film a counting and breaking voltages are obtained. Finally, an average voltage of all them is estimated. (Author)

  8. Study of mast cell count in skin tags

    Directory of Open Access Journals (Sweden)

    Zaher Hesham

    2007-01-01

    Full Text Available Background: Skin tags or acrochordons are common tumors of middle-aged and elderly subjects. They consist of loose fibrous tissue and occur mainly on the neck and major flexures as small, soft, pedunculated protrusions. Objectives: The aim was to compare the mast cells count in skin tags to adjacent normal skin in diabetic and nondiabetic participants in an attempt to elucidate the possible role of mast cells in the pathogenesis of skin tags. Participants and Methods: Thirty participants with skin tags were divided into group I (15 nondiabetic participants and group II (15 diabetic participants. Three biopsies were obtained from each participant: a large skin tag, a small skin tag and adjacent normal skin. Mast cell count from all the obtained sections was carried out, and the mast cell density was expressed as the average mast cell count/high power field (HPF. Results: A statistically significant increase in mast cells count in skin tags in comparison to normal skin was detected in group I and group II. There was no statistically significant difference between mast cell counts in skin tags of both the groups. Conclusion: Both the mast cell mediators and hyperinsulinemia are capable of inducing fibroblast proliferation and epidermal hyperplasia that are the main pathologic abnormalities seen in all types of skin tags. However, the presence of mast cells in all examined skin tags regardless of diabetes and obesity may point to the possible crucial role of mast cells in the etiogenesis of skin tags through its interaction with fibroblasts and keratinocytes.

  9. Counting in Lattices: Combinatorial Problems from Statistical Mechanics.

    Science.gov (United States)

    Randall, Dana Jill

    In this thesis we consider two classical combinatorial problems arising in statistical mechanics: counting matchings and self-avoiding walks in lattice graphs. The first problem arises in the study of the thermodynamical properties of monomers and dimers (diatomic molecules) in crystals. Fisher, Kasteleyn and Temperley discovered an elegant technique to exactly count the number of perfect matchings in two dimensional lattices, but it is not applicable for matchings of arbitrary size, or in higher dimensional lattices. We present the first efficient approximation algorithm for computing the number of matchings of any size in any periodic lattice in arbitrary dimension. The algorithm is based on Monte Carlo simulation of a suitable Markov chain and has rigorously derived performance guarantees that do not rely on any assumptions. In addition, we show that these results generalize to counting matchings in any graph which is the Cayley graph of a finite group. The second problem is counting self-avoiding walks in lattices. This problem arises in the study of the thermodynamics of long polymer chains in dilute solution. While there are a number of Monte Carlo algorithms used to count self -avoiding walks in practice, these are heuristic and their correctness relies on unproven conjectures. In contrast, we present an efficient algorithm which relies on a single, widely-believed conjecture that is simpler than preceding assumptions and, more importantly, is one which the algorithm itself can test. Thus our algorithm is reliable, in the sense that it either outputs answers that are guaranteed, with high probability, to be correct, or finds a counterexample to the conjecture. In either case we know we can trust our results and the algorithm is guaranteed to run in polynomial time. This is the first algorithm for counting self-avoiding walks in which the error bounds are rigorously controlled. This work was supported in part by an AT&T graduate fellowship, a University of

  10. An automated cell-counting algorithm for fluorescently-stained cells in migration assays

    Directory of Open Access Journals (Sweden)

    Novielli Nicole M

    2011-10-01

    Full Text Available Abstract A cell-counting algorithm, developed in Matlab®, was created to efficiently count migrated fluorescently-stained cells on membranes from migration assays. At each concentration of cells used (10,000, and 100,000 cells, images were acquired at 2.5 ×, 5 ×, and 10 × objective magnifications. Automated cell counts strongly correlated to manual counts (r2 = 0.99, P

  11. How fast can quantum annealers count?

    International Nuclear Information System (INIS)

    Hen, Itay

    2014-01-01

    We outline an algorithm for the quantum counting problem using adiabatic quantum computation (AQC). We show that the mechanism of quantum-adiabatic evolution may be utilized toward estimating the number of solutions to a problem, and not only to find them. Using local adiabatic evolution, a process in which the adiabatic procedure is performed at a variable rate, the problem of counting the number of marked items in an unstructured database is solved quadratically faster than the corresponding classical algorithm. The above algorithm provides further evidence for the potentially powerful capabilities of AQC as a paradigm for more efficient problem solving on a quantum computer, and may be used as the basis for solving more sophisticated problems. (paper)

  12. Phase space quark counting rule

    International Nuclear Information System (INIS)

    Wei-gin, C.; Lo, S.

    1980-01-01

    A simple quark counting rule based on phase space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions

  13. BMI in relation to sperm count: an updated systematic review and collaborative meta-analysis.

    Science.gov (United States)

    Sermondade, N; Faure, C; Fezeu, L; Shayeb, A G; Bonde, J P; Jensen, T K; Van Wely, M; Cao, J; Martini, A C; Eskandar, M; Chavarro, J E; Koloszar, S; Twigt, J M; Ramlau-Hansen, C H; Borges, E; Lotti, F; Steegers-Theunissen, R P M; Zorn, B; Polotsky, A J; La Vignera, S; Eskenazi, B; Tremellen, K; Magnusdottir, E V; Fejes, I; Hercberg, S; Lévy, R; Czernichow, S

    2013-01-01

    BACKGROUND The global obesity epidemic has paralleled a decrease in semen quality. Yet, the association between obesity and sperm parameters remains controversial. The purpose of this report was to update the evidence on the association between BMI and sperm count through a systematic review with meta-analysis. METHODS A systematic review of available literature (with no language restriction) was performed to investigate the impact of BMI on sperm count. Relevant studies published until June 2012 were identified from a Pubmed and EMBASE search. We also included unpublished data (n = 717 men) obtained from the Infertility Center of Bondy, France. Abstracts of relevant articles were examined and studies that could be included in this review were retrieved. Authors of relevant studies for the meta-analysis were contacted by email and asked to provide standardized data. RESULTS A total of 21 studies were included in the meta-analysis, resulting in a sample of 13 077 men from the general population and attending fertility clinics. Data were stratified according to the total sperm count as normozoospermia, oligozoospermia and azoospermia. Standardized weighted mean differences in sperm concentration did not differ significantly across BMI categories. There was a J-shaped relationship between BMI categories and risk of oligozoospermia or azoospermia. Compared with men of normal weight, the odds ratio (95% confidence interval) for oligozoospermia or azoospermia was 1.15 (0.93-1.43) for underweight, 1.11 (1.01-1.21) for overweight, 1.28 (1.06-1.55) for obese and 2.04 (1.59-2.62) for morbidly obese men. CONCLUSIONS Overweight and obesity were associated with an increased prevalence of azoospermia or oligozoospermia. The main limitation of this report is that studied populations varied, with men recruited from both the general population and infertile couples. Whether weight normalization could improve sperm parameters should be evaluated further.

  14. A high dynamic range pulse counting detection system for mass spectrometry.

    Science.gov (United States)

    Collings, Bruce A; Dima, Martian D; Ivosev, Gordana; Zhong, Feng

    2014-01-30

    A high dynamic range pulse counting system has been developed that demonstrates an ability to operate at up to 2e8 counts per second (cps) on a triple quadrupole mass spectrometer. Previous pulse counting detection systems have typically been limited to about 1e7 cps at the upper end of the systems dynamic range. Modifications to the detection electronics and dead time correction algorithm are described in this paper. A high gain transimpedance amplifier is employed that allows a multi-channel electron multiplier to be operated at a significantly lower bias potential than in previous pulse counting systems. The system utilises a high-energy conversion dynode, a multi-channel electron multiplier, a high gain transimpedance amplifier, non-paralysing detection electronics and a modified dead time correction algorithm. Modification of the dead time correction algorithm is necessary due to a characteristic of the pulse counting electronics. A pulse counting detection system with the capability to count at ion arrival rates of up to 2e8 cps is described. This is shown to provide a linear dynamic range of nearly five orders of magnitude for a sample of aprazolam with concentrations ranging from 0.0006970 ng/mL to 3333 ng/mL while monitoring the m/z 309.1 → m/z 205.2 transition. This represents an upward extension of the detector's linear dynamic range of about two orders of magnitude. A new high dynamic range pulse counting system has been developed demonstrating the ability to operate at up to 2e8 cps on a triple quadrupole mass spectrometer. This provides an upward extension of the detector's linear dynamic range by about two orders of magnitude over previous pulse counting systems. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Automated volume of interest delineation and rendering of cone beam CT images in interventional cardiology

    Science.gov (United States)

    Lorenz, Cristian; Schäfer, Dirk; Eshuis, Peter; Carroll, John; Grass, Michael

    2012-02-01

    Interventional C-arm systems allow the efficient acquisition of 3D cone beam CT images. They can be used for intervention planning, navigation, and outcome assessment. We present a fast and completely automated volume of interest (VOI) delineation for cardiac interventions, covering the whole visceral cavity including mediastinum and lungs but leaving out rib-cage and spine. The problem is addressed in a model based approach. The procedure has been evaluated on 22 patient cases and achieves an average surface error below 2mm. The method is able to cope with varying image intensities, varying truncations due to the limited reconstruction volume, and partially with heavy metal and motion artifacts.

  16. Recent trends in counts of migrant hawks from northeastern North America

    Science.gov (United States)

    Titus, K.; Fuller, M.R.

    1990-01-01

    Using simple regression, pooled-sites route-regression, and nonparametric rank-trend analyses, we evaluated trends in counts of hawks migrating past 6 eastern hawk lookouts from 1972 to 1987. The indexing variable was the total count for a season. Bald eagle (Haliaeetus leucocephalus), peregrine falcon (Falco peregrinus), merlin (F. columbarius), osprey (Pandion haliaetus), and Cooper's hawk (Accipiter cooperii) counts increased using route-regression and nonparametric methods (P 0.10). We found no consistent trends (P > 0.10) in counts of sharp-shinned hawks (A. striatus), northern goshawks (A. gentilis) red-shouldered hawks (Buteo lineatus), red-tailed hawks (B. jamaicensis), rough-legged hawsk (B. lagopus), and American kestrels (F. sparverius). Broad-winged hawk (B. platypterus) counts declined (P < 0.05) based on the route-regression method. Empirical comparisons of our results with those for well-studied species such as the peregrine falcon, bald eagle, and osprey indicated agreement with nesting surveys. We suggest that counts of migrant hawks are a useful and economical method for detecting long-term trends in species across regions, particularly for species that otherwise cannot be easily surveyed.

  17. Comprehensive nuclear counting and detector characterisation system for the radiochemistry laboratory

    International Nuclear Information System (INIS)

    Parthasarathy, R.; Saisubalakshmi, D.; Mishra, G.K.; Srinivas, K.C.; Venkatasubramani, C.R.

    2004-01-01

    The paper describes a comprehensive nuclear pulse counting system that can cater to up to seven nuclear detector set-ups located in different places in the laboratory. Each detector set up has an interfacing module that conditions the amplifier pulses and transmits them to a common counting system. The microcontroller-based system receives these pulses through a multiplexer and counts the pulses for a user specified preset time. The system has a routine to determine detector plateau characteristics and fix the detector operating voltage. In this mode, the system collects the EHT-versus- counts data in a EHT programmed sequence and plots the profile. The system conducts the counting routine for a stipulated number of times and does all necessary statistical tests to ensure the proper functioning of the detector under test. The system also includes a test routine that checks the performance of the counting system by connecting it to a local pulse generator. The microcontroller based system interacts with a PC through RS232 communication for user interaction and reporting. (author)

  18. An automated approach for annual layer counting in ice cores

    Directory of Open Access Journals (Sweden)

    M. Winstrup

    2012-11-01

    Full Text Available A novel method for automated annual layer counting in seasonally-resolved paleoclimate records has been developed. It relies on algorithms from the statistical framework of hidden Markov models (HMMs, which originally was developed for use in machine speech recognition. The strength of the layer detection algorithm lies in the way it is able to imitate the manual procedures for annual layer counting, while being based on statistical criteria for annual layer identification. The most likely positions of multiple layer boundaries in a section of ice core data are determined simultaneously, and a probabilistic uncertainty estimate of the resulting layer count is provided, ensuring an objective treatment of ambiguous layers in the data. Furthermore, multiple data series can be incorporated and used simultaneously. In this study, the automated layer counting algorithm has been applied to two ice core records from Greenland: one displaying a distinct annual signal and one which is more challenging. The algorithm shows high skill in reproducing the results from manual layer counts, and the resulting timescale compares well to absolute-dated volcanic marker horizons where these exist.

  19. Poissonian and binomial models in radionuclide metrology by liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Malonda, A.

    1990-01-01

    Binomial and Poissonian models developed for calculating the counting efficiency from a free parameter is analysed in this paper. This model have been applied to liquid scintillator counting systems with two or three photomultipliers. It is mathematically demostrated that both models are equivalent and that the counting efficiencies calculated either from one or the other model are identical. (Author)

  20. Phase-space quark counting rule

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Gin, Chao; Lo, Shui-Yin [Academia Sinica, Beijing (China). Inst. of High Energy Physics

    1981-05-21

    A simple quark counting rule based on the phase-space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter-free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions.

  1. Advanced digital counting rate meter for gamma ray logging

    International Nuclear Information System (INIS)

    Kannan, S.; Meenakshi Sundari, A.; Rai, A.K.

    2013-01-01

    A compact, hand held controller based Advanced Digital Count Rate Meter (ADCRM) as a replacement of bulky Count Rate (analog) Meters (SBL-2A) was designed, developed and fabricated to carry out Gamma-Ray borehole logging with Geiger Muller (GM) tubes and Scintillation (SC) detectors. In the hardware the functionality of analog meter simulation, digital counting of gamma events and auto reference adjustment to use different length of armour cable winches were implemented. The in-built software evaluates grade in ppm and at the end of logging, the reports are prepared automatically. ADCRM was developed in-house to assist the uranium mineral exploration in AMD. (author)

  2. Can reliable sage-grouse lek counts be obtained using aerial infrared technology

    Science.gov (United States)

    Gillette, Gifford L.; Coates, Peter S.; Petersen, Steven; Romero, John P.

    2013-01-01

    More effective methods for counting greater sage-grouse (Centrocercus urophasianus) are needed to better assess population trends through enumeration or location of new leks. We describe an aerial infrared technique for conducting sage-grouse lek counts and compare this method with conventional ground-based lek count methods. During the breeding period in 2010 and 2011, we surveyed leks from fixed-winged aircraft using cryogenically cooled mid-wave infrared cameras and surveyed the same leks on the same day from the ground following a standard lek count protocol. We did not detect significant differences in lek counts between surveying techniques. These findings suggest that using a cryogenically cooled mid-wave infrared camera from an aerial platform to conduct lek surveys is an effective alternative technique to conventional ground-based methods, but further research is needed. We discuss multiple advantages to aerial infrared surveys, including counting in remote areas, representing greater spatial variation, and increasing the number of counted leks per season. Aerial infrared lek counts may be a valuable wildlife management tool that releases time and resources for other conservation efforts. Opportunities exist for wildlife professionals to refine and apply aerial infrared techniques to wildlife monitoring programs because of the increasing reliability and affordability of this technology.

  3. Factor V Leiden is associated with increased sperm count

    NARCIS (Netherlands)

    van Mens, T. E.; Joensen, U. N.; Bochdanovits, Z.; Takizawa, A.; Peter, J.; Jørgensen, N.; Szecsi, P. B.; Meijers, J. C. M.; Weiler, H.; Rajpert-de Meyts, E.; Repping, S.; Middeldorp, S.

    2017-01-01

    STUDY QUESTION: Is the thrombophilia mutation factor V Leiden (FVL) associated with an increased total sperm count? SUMMARY ANSWER: Carriers of FVL have a higher total sperm count than non-FVL-carriers, which could not be explained by genetic linkage or by observations in a FVL-mouse model. WHAT IS

  4. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    Science.gov (United States)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Empirical Derivation of Correction Factors for Human Spiral Ganglion Cell Nucleus and Nucleolus Count Units.

    Science.gov (United States)

    Robert, Mark E; Linthicum, Fred H

    2016-01-01

    Profile count method for estimating cell number in sectioned tissue applies a correction factor for double count (resulting from transection during sectioning) of count units selected to represent the cell. For human spiral ganglion cell counts, we attempted to address apparent confusion between published correction factors for nucleus and nucleolus count units that are identical despite the role of count unit diameter in a commonly used correction factor formula. We examined a portion of human cochlea to empirically derive correction factors for the 2 count units, using 3-dimensional reconstruction software to identify double counts. The Neurotology and House Histological Temporal Bone Laboratory at University of California at Los Angeles. Using a fully sectioned and stained human temporal bone, we identified and generated digital images of sections of the modiolar region of the lower first turn of cochlea, identified count units with a light microscope, labeled them on corresponding digital sections, and used 3-dimensional reconstruction software to identify double-counted count units. For 25 consecutive sections, we determined that double-count correction factors for nucleus count unit (0.91) and nucleolus count unit (0.92) matched the published factors. We discovered that nuclei and, therefore, spiral ganglion cells were undercounted by 6.3% when using nucleolus count units. We determined that correction factors for count units must include an element for undercounting spiral ganglion cells as well as the double-count element. We recommend a correction factor of 0.91 for the nucleus count unit and 0.98 for the nucleolus count unit when using 20-µm sections. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  6. A computer simulation used to investigate optimization in low level counting

    International Nuclear Information System (INIS)

    Brown, R.C.; Kephart, G.S.

    1984-01-01

    The differential form of the interval distribution for randomly spaced events such as radioactive decay is represented as dP/sub t/=ae - /supat/dt, the Poisson distribution. As applied to radioactive decay, this states that the probability (dP/sub t/) of the duration of a particular interval (elapsed time between counts) will be between t and t+dt as a function of the count rate (a). Thus a logarithmic transformation of this probability distribution results in a linear function whose slope and intercept are defined by the count rate. The effort expended in defining the interval distribution of a given radiation measurement equates in the laboratory to measuring and accumulating discrete time intervals between events rather than the usual approach of counting events per unit time. It follows from basic information theory that this greater effort should result in an improved statistical confidence in determinations of the ''true'' count rate (a). Using a random number generator as an analog of the discrete decay event, the authors have devised a Monte Carlo approach to investigate application of the above theory to the low level counting situation. This investigative approach is well suited to sensitivity analyses such that any constraints on proposed optimization techniques can be well defined prior to introducing these methods into the counting requirements in the laboratory

  7. Decay counting in the age of AMS

    International Nuclear Information System (INIS)

    Arnold, J.R.

    1987-01-01

    Up to the advent of AMS, all the accomplishments of 14 C dating, and the studies of 10 Be and other long-lived radionuclides, were made by low-level decay counting, the technique pioneered by W.F. Libby. It will hardly be news to people at this conference that, while much was accomplished in the three decades when counting prevailed, the world has now changed decisively. I will try to give an account of where low-level counting was 'before the revolution', and of what its usefulness is today. There are still some remarkable examples of its application, the best being the neutrino experiment of Raymond Davis, and its potential successors. Some cosmogenic nuclides, whose half-lives are less than 10 3 yr, are still best measured by decay; this will continue unless the overall ion yield of AMS systems rises markedly from present levels. One long-lived nuclide, 53 Mn, is still best measured by neutron activation as 312-day 54 Mn, but this may not continue. (orig.)

  8. Accuracy in activation analysis: count rate effects

    International Nuclear Information System (INIS)

    Lindstrom, R.M.; Fleming, R.F.

    1980-01-01

    The accuracy inherent in activation analysis is ultimately limited by the uncertainty of counting statistics. When careful attention is paid to detail, several workers have shown that all systematic errors can be reduced to an insignificant fraction of the total uncertainty, even when the statistical limit is well below one percent. A matter of particular importance is the reduction of errors due to high counting rate. The loss of counts due to random coincidence (pulse pileup) in the amplifier and to digitization time in the ADC may be treated as a series combination of extending and non-extending dead times, respectively. The two effects are experimentally distinct. Live timer circuits in commercial multi-channel analyzers compensate properly for ADC dead time for long-lived sources, but not for pileup. Several satisfactory solutions are available, including pileup rejection and dead time correction circuits, loss-free ADCs, and computed corrections in a calibrated system. These methods are sufficiently reliable and well understood that a decaying source can be measured routinely with acceptably small errors at a dead time as high as 20 percent

  9. Decay counting in the age of AMS

    International Nuclear Information System (INIS)

    Arnold, J.R.

    1987-01-01

    Up to the advent of AMS, all the accomplishments of 14 C dating, and the studies of 10 Be and other long-lived radionuclides, were made by low-level decay counting, the technique pioneered by W.F. Libby. It will hardly be news to people at this conference that, while much was accomplished in the three decades when counting prevailed, the world has now changed decisively. He will try to give an account of where low-level counting was before the revolution, and of what its usefulness is today. There are still some remarkable examples of its application, the best being the neutrino experiment of Raymond Davis, and its potential successors. Some cosmogenic nuclides, whose half-lives are less than 10 3 yr, are still best measured by decay; this will continue unless the overall ion yield of AMS systems rises markedly from present levels. One long-lived nuclide, 53 Mn, is still best measured by neutron activation as 312-day 54 Mn, but this may not continue

  10. Experimental Study for Automatic Colony Counting System Based Onimage Processing

    Science.gov (United States)

    Fang, Junlong; Li, Wenzhe; Wang, Guoxin

    Colony counting in many colony experiments is detected by manual method at present, therefore it is difficult for man to execute the method quickly and accurately .A new automatic colony counting system was developed. Making use of image-processing technology, a study was made on the feasibility of distinguishing objectively white bacterial colonies from clear plates according to the RGB color theory. An optimal chromatic value was obtained based upon a lot of experiments on the distribution of the chromatic value. It has been proved that the method greatly improves the accuracy and efficiency of the colony counting and the counting result is not affected by using inoculation, shape or size of the colony. It is revealed that automatic detection of colony quantity using image-processing technology could be an effective way.

  11. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    then consists of a sequence (or tree) of rule applications and provides an independently checkable certificate of the validity of the result. This reduces the need to trust, or otherwise verify, the correctness of the vote counting software once the certificate has been validated. Using a rule...

  12. Recent progress with digital coincidence counting

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Watt, G.C.; Alexiev, D.

    1999-01-01

    Digital Coincidence Counting (DCC) is a new technique, based on the older method of analogue coincidence counting. It has been developed by ANSTO as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue to digital converter acquisition system for collecting pulse information from a 4Π beta detector and a NaI(Tl) gamma detector. The digitised pulse information is stored on a high speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software based algorithms. The system is operational and results are now being routinely collected and analysed. Some of the early work is presented for Co-60, Na-22 and Sm-153

  13. Bayesian Kernel Mixtures for Counts.

    Science.gov (United States)

    Canale, Antonio; Dunson, David B

    2011-12-01

    Although Bayesian nonparametric mixture models for continuous data are well developed, there is a limited literature on related approaches for count data. A common strategy is to use a mixture of Poissons, which unfortunately is quite restrictive in not accounting for distributions having variance less than the mean. Other approaches include mixing multinomials, which requires finite support, and using a Dirichlet process prior with a Poisson base measure, which does not allow smooth deviations from the Poisson. As a broad class of alternative models, we propose to use nonparametric mixtures of rounded continuous kernels. An efficient Gibbs sampler is developed for posterior computation, and a simulation study is performed to assess performance. Focusing on the rounded Gaussian case, we generalize the modeling framework to account for multivariate count data, joint modeling with continuous and categorical variables, and other complications. The methods are illustrated through applications to a developmental toxicity study and marketing data. This article has supplementary material online.

  14. Differential white cell count by centrifugal microfluidics.

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    2010-07-01

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

  15. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  16. The distribution of controlled drugs on banknotes via counting machines.

    Science.gov (United States)

    Carter, James F; Sleeman, Richard; Parry, Joanna

    2003-03-27

    Bundles of paper, similar to sterling banknotes, were counted in banks in England and Wales. Subsequent analysis showed that the counting process, both by machine and by hand, transferred nanogram amounts of cocaine to the paper. Crystalline material, similar to cocaine hydrochloride, could be observed on the surface of the paper following counting. The geographical distribution of contamination broadly followed Government statistics for cocaine usage within the UK. Diacetylmorphine, Delta(9)-tetrahydrocannabinol (THC) and 3,4-methylenedioxymethylamphetamine (MDMA) were not detected during this study.

  17. Scale-dependent associations of Band-tailed Pigeon counts at mineral sites

    Science.gov (United States)

    Overton, Cory T.; Casazza, Michael L.; Coates, Peter S.

    2010-01-01

    The abundance of Band-tailed Pigeons (Patagioenas fasciata monilis) has declined substantially from historic numbers along the Pacific Coast. Identification of patterns and causative factors of this decline are hampered because habitat use data are limited, and temporal and spatial variability patterns associated with population indices are not known. Furthermore, counts are influenced not only by pigeon abundance but also by rate of visitation to mineral sites, which may not be consistent. To address these issues, we conducted mineral site counts during 2001 and 2002 at 20 locations from 4 regions in the Pacific Northwest, including central Oregon and western Washington, USA, and British Columbia, Canada. We developed inference models that consisted of environmental factors and spatial characteristics at multiple spatial scales. Based on information theory, we compared models within a final set that included variables measured at 3 spatial scales (0.03 ha, 3.14 ha, and 7850 ha). Pigeon counts increased from central Oregon through northern Oregon and decreased into British Columbia. After accounting for this spatial pattern, we found that pigeon counts increased 12% ± 2.7 with a 10% increase in the amount of deciduous forested area within 100 m from a mineral site. Also, distance from the mineral site of interest to the nearest known mineral site was positively related to pigeon counts. These findings provide direction for future research focusing on understanding the relationships between indices of relative abundance and complete counts (censuses) of pigeon populations by identifying habitat characteristics that might influence visitation rates. Furthermore, our results suggest that spatial arrangement of mineral sites influences Band-tailed Pigeon counts and the populations which those counts represent.

  18. Development of an automated asbestos counting software based on fluorescence microscopy.

    Science.gov (United States)

    Alexandrov, Maxym; Ichida, Etsuko; Nishimura, Tomoki; Aoki, Kousuke; Ishida, Takenori; Hirota, Ryuichi; Ikeda, Takeshi; Kawasaki, Tetsuo; Kuroda, Akio

    2015-01-01

    An emerging alternative to the commonly used analytical methods for asbestos analysis is fluorescence microscopy (FM), which relies on highly specific asbestos-binding probes to distinguish asbestos from interfering non-asbestos fibers. However, all types of microscopic asbestos analysis require laborious examination of large number of fields of view and are prone to subjective errors and large variability between asbestos counts by different analysts and laboratories. A possible solution to these problems is automated counting of asbestos fibers by image analysis software, which would lower the cost and increase the reliability of asbestos testing. This study seeks to develop a fiber recognition and counting software for FM-based asbestos analysis. We discuss the main features of the developed software and the results of its testing. Software testing showed good correlation between automated and manual counts for the samples with medium and high fiber concentrations. At low fiber concentrations, the automated counts were less accurate, leading us to implement correction mode for automated counts. While the full automation of asbestos analysis would require further improvements in accuracy of fiber identification, the developed software could already assist professional asbestos analysts and record detailed fiber dimensions for the use in epidemiological research.

  19. Examining secular trends and seasonality in count data using dynamic generalized linear modelling: a new methodological approach illustrated with hospital discharge data on myocardial infarction.

    Science.gov (United States)

    Lundbye-Christensen, S; Dethlefsen, C; Gorst-Rasmussen, A; Fischer, T; Schønheyder, H C; Rothman, K J; Sørensen, H T

    2009-01-01

    Time series of incidence counts often show secular trends and seasonal patterns. We present a model for incidence counts capable of handling a possible gradual change in growth rates and seasonal patterns, serial correlation, and overdispersion. The model resembles an ordinary time series regression model for Poisson counts. It differs in allowing the regression coefficients to vary gradually over time in a random fashion. During the 1983-1999 period, 17,989 incidents of acute myocardial infarction were recorded in the Hospital Discharge Registry for the county of North Jutland, Denmark. Records were updated daily. A dynamic model with a seasonal pattern and an approximately linear trend was fitted to the data, and diagnostic plots indicated a good model fit. The analysis conducted with the dynamic model revealed peaks coinciding with above-average influenza A activity. On average the dynamic model estimated a higher peak-to-trough ratio than traditional models, and showed gradual changes in seasonal patterns. Analyses conducted with this model provide insights not available from more traditional approaches.

  20. Cherenkov radiation effects on counting efficiency in extremely quenched liquid scintillation samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.; Rodriguez Barquero, L.

    1993-01-01

    The CIEMAT/NIST tracer method has successfully standardized nuclides with diverse quench values and decay schemes in liquid scintillation counting. However, the counting efficiency is computed inaccurately for extremely quenched samples. This article shows that when samples are extremely quenched, the counting efficiency in high-energy beta-ray nuclides depends principally on the Cherenkov effect. A new technique is described for quench determination, which makes the measurement of counting efficiency possible when scintillation counting approaches zero. A new efficiency computation model for pure beta-ray nuclides is also described. The results of the model are tested experimentally for 89 Sr, 90 Y, 36 Cl and 204 Tl nuclides with independence of the quench level. (orig.)

  1. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    1974-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers which give homogeneous monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous monophasic-appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  2. Quantitative monitoring of the fluorination process by neutron counting

    International Nuclear Information System (INIS)

    Russo, P.A.; Appert, Q.D.; Biddle, R.S.; Kelley, T.A.; Martinez, M.M.; West, M.H.

    1993-01-01

    Plutonium metal is produced by reducing PuF 4 prepared from PuO 2 by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron (α,n) reactions on fluorine targets compared to the (more than 100 times) smaller α,n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated 3 He-gas proportional counters. Results include a calibration of the real-time neutron-count-rate indicator for the extent of fluorination using reference values obtained from destructive analysis of samples from the blended fluoroinated batch

  3. Eosinophil count, allergies, and rejection in pediatric heart transplant recipients.

    Science.gov (United States)

    Arbon, Kate S; Albers, Erin; Kemna, Mariska; Law, Sabrina; Law, Yuk

    2015-08-01

    Allograft rejection and long-term immunosuppression remain significant challenges in pediatric heart transplantation. Pediatric recipients are known to have fewer rejection episodes and to develop more allergic conditions than adults. A T-helper 2 cell dominant phenotype, manifested clinically by allergies and an elevated eosinophil count, may be associated with immunologic quiescence in transplant recipients. This study assessed whether the longitudinal eosinophil count and an allergic phenotype were associated with freedom from rejection. This single-center, longitudinal, observational study included 86 heart transplant patients monitored from 1994 to 2011. Post-transplant biannual complete blood counts, allergic conditions, and clinical characteristics related to rejection risk were examined. At least 1 episode of acute cellular rejection (ACR) occurred in 38 patients (44%), antibody-mediated rejection (AMR) occurred in 11 (13%), and 49 patients (57%) were diagnosed with an allergic condition. Patients with ACR or AMR had a lower eosinophil count compared with non-rejectors (p = 0.011 and p = 0.022, respectively). In the multivariable regression analysis, the presence of panel reactive antibodies to human leukocyte antigen I (p = 0.014) and the median eosinophil count (p = 0.011) were the only independent covariates associated with AMR. Eosinophil count (p = 0.010) and female sex (p = 0.009) were independent risk factors for ACR. Allergic conditions or young age at transplant were not protective from rejection. This study demonstrates a novel association between a high eosinophil count and freedom from rejection. Identifying a biomarker for low rejection risk may allow a reduction in immunosuppression. Further investigation into the role of the T-helper 2 cell phenotype and eosinophils in rejection quiescence is warranted. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  4. A measurement technique for counting processes

    International Nuclear Information System (INIS)

    Cantoni, V.; Pavia Univ.; De Lotto, I.; Valenziano, F.

    1980-01-01

    A technique for the estimation of first and second order properties of a stationary counting process is presented here which uses standard instruments for analysis of a continuous stationary random signal. (orig.)

  5. VSRR Provisional Drug Overdose Death Counts

    Data.gov (United States)

    U.S. Department of Health & Human Services — This data contains provisional counts for drug overdose deaths based on a current flow of mortality data in the National Vital Statistics System. National...

  6. Effective dark count rate reduction by modified SPAD gating circuit

    Energy Technology Data Exchange (ETDEWEB)

    Prochazka, Ivan; Blazej, Josef, E-mail: blazej@fjfi.cvut.cz; Kodet, Jan

    2015-07-01

    For our main application of single photon counting avalanche detectors in focus – laser ranging of space objects and laser time transfer – the ultimate requirements are relatively large and homogeneous active area having a diameter of 100 to 200 µm and a sub-picosecond stability of timing. The detector dark count rate and after-pulsing probability are parameters of relatively lower, but not negligible importance. In presented paper we will focused on them. We have developed a new active quenching and gating scheme which can reduce afterpulsing effect and hence also effective dark count rate at lower temperature. In satellite laser ranging system the effective dark count rate was reduced more than 35 times. This improvement will contribute in increasing the data yield and hence to increase precision and productivity. - Highlights: • Signal and quenching path in a control circuit stayed unaffected by gating. • The detector package optimized for laser time transfer systems is considered. • After-pulsing effect is reduced by a modification of the use of gate signal. • The dark count rate is reduced for gate rates of the order of units of kHz.

  7. Average sperm count remains unchanged despite reduction in maternal smoking

    DEFF Research Database (Denmark)

    Priskorn, L; Nordkap, L; Bang, A K

    2018-01-01

    STUDY QUESTION: How are temporal trends in lifestyle factors, including exposure to maternal smoking in utero, associated to semen quality in young men from the general population? SUMMARY ANSWER: Exposure to maternal smoking was associated with lower sperm counts but no overall increase in sperm...... temporal trends. Parental age increased, and exposure in utero to maternal smoking declined from 40% among men investigated in 1996-2000 to 18% among men investigated in 2011-2016. Exposure to maternal smoking was associated with lower sperm counts but no overall increase in sperm counts was observed...... counts was observed during the study period despite a decrease in this exposure. WHAT IS KNOWN ALREADY: Meta-analyses suggest a continuous decline in semen quality but few studies have investigated temporal trends in unselected populations recruited and analysed with the same protocol over a long period...

  8. Nearest neighbors by neighborhood counting.

    Science.gov (United States)

    Wang, Hui

    2006-06-01

    Finding nearest neighbors is a general idea that underlies many artificial intelligence tasks, including machine learning, data mining, natural language understanding, and information retrieval. This idea is explicitly used in the k-nearest neighbors algorithm (kNN), a popular classification method. In this paper, this idea is adopted in the development of a general methodology, neighborhood counting, for devising similarity functions. We turn our focus from neighbors to neighborhoods, a region in the data space covering the data point in question. To measure the similarity between two data points, we consider all neighborhoods that cover both data points. We propose to use the number of such neighborhoods as a measure of similarity. Neighborhood can be defined for different types of data in different ways. Here, we consider one definition of neighborhood for multivariate data and derive a formula for such similarity, called neighborhood counting measure or NCM. NCM was tested experimentally in the framework of kNN. Experiments show that NCM is generally comparable to VDM and its variants, the state-of-the-art distance functions for multivariate data, and, at the same time, is consistently better for relatively large k values. Additionally, NCM consistently outperforms HEOM (a mixture of Euclidean and Hamming distances), the "standard" and most widely used distance function for multivariate data. NCM has a computational complexity in the same order as the standard Euclidean distance function and NCM is task independent and works for numerical and categorical data in a conceptually uniform way. The neighborhood counting methodology is proven sound for multivariate data experimentally. We hope it will work for other types of data.

  9. The real-time fitting of radioactive decay curves. Pt. 3. Counting during sampling

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1994-01-01

    An analysis of a least-squares method for the real-time fitting of the theoretical total count function to the actual total count from radioactive decays has been given previously for the case where counting takes place after a sample is taken. The counting may be done in a number of different counting systems which distinguish between different types or energies of radiation emitted from the sample. The method would allow real-time determination of the numbers of atoms and hence activities of the individual isotopes present and has been designated the Time Evolved Least-Squares method (TELS). If the radioactivity which is to be measured exists as an aerosol or in a form where a sample is taken at a constant rate it may be possible to count during sampling and by so doing reduce the total time required to determine the activity of the individual isotopes present. The TELS method is extended here to the case where counting and the evaluation of the activity takes place concurrently with the sampling. The functions which need to be evaluated are derived and the calculations required to implement the method are discussed. As with the TELS method of counting after sampling the technique of counting during sampling and the simultaneous evaluation of activity could be achieved in real-time. Results of testing the method by computer simulation for two counting schemes for the descendants of radon are presented. ((orig.))

  10. Maximum entropy deconvolution of low count nuclear medicine images

    International Nuclear Information System (INIS)

    McGrath, D.M.

    1998-12-01

    Maximum entropy is applied to the problem of deconvolving nuclear medicine images, with special consideration for very low count data. The physics of the formation of scintigraphic images is described, illustrating the phenomena which degrade planar estimates of the tracer distribution. Various techniques which are used to restore these images are reviewed, outlining the relative merits of each. The development and theoretical justification of maximum entropy as an image processing technique is discussed. Maximum entropy is then applied to the problem of planar deconvolution, highlighting the question of the choice of error parameters for low count data. A novel iterative version of the algorithm is suggested which allows the errors to be estimated from the predicted Poisson mean values. This method is shown to produce the exact results predicted by combining Poisson statistics and a Bayesian interpretation of the maximum entropy approach. A facility for total count preservation has also been incorporated, leading to improved quantification. In order to evaluate this iterative maximum entropy technique, two comparable methods, Wiener filtering and a novel Bayesian maximum likelihood expectation maximisation technique, were implemented. The comparison of results obtained indicated that this maximum entropy approach may produce equivalent or better measures of image quality than the compared methods, depending upon the accuracy of the system model used. The novel Bayesian maximum likelihood expectation maximisation technique was shown to be preferable over many existing maximum a posteriori methods due to its simplicity of implementation. A single parameter is required to define the Bayesian prior, which suppresses noise in the solution and may reduce the processing time substantially. Finally, maximum entropy deconvolution was applied as a pre-processing step in single photon emission computed tomography reconstruction of low count data. Higher contrast results were

  11. Determining reactor fuel elements broken by Cerenkov counting

    International Nuclear Information System (INIS)

    Guo Juhao; Dong Shiyuan; Feng Yuying

    1996-01-01

    The basis and method of determining fuel elements broken in a reactor by Cerenkov counting measured with liquid scintillation spectrometer are introduced. The radioactive characteristic of the radiation nuclides generating Cherenkov radiation in the primary water of 200 MW nuclear district heating reactor is analyzed. The activity of the activation products in the primary water and the fission products in the fuel elements are calculated. A feasibility of Cerenkov counting measure was analyzed. This method is simple and quick

  12. CERN{sub D}xCTA counting mode chip

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, D. [CERN, CH-1211 Geneva 23 (Switzerland)], E-mail: danielle.moraes@cern.ch; Kaplon, J. [CERN, CH-1211 Geneva 23 (Switzerland); Nygard, E. [Interon AS, Asker, Norway and DX-ray Inc., Northridge, CA (United States)

    2008-06-11

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 {mu}m CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e{sup -}, for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors.

  13. The index of abdominal obesity as a marker of disorder of blood serum triglicerides fatty-acid spectrum in patients with diabetes mellitus type 2

    Directory of Open Access Journals (Sweden)

    Наталія Миколаївна Кушнарьова

    2015-12-01

    Full Text Available Aim of research. To determine the possibility to use the visceral obesity index (VOI for diagnostics of lipid metabolism disorders in patients with diabetes mellitus (DM type 2 on the base of the study of adipose tissue and triglycerides fatty acids content in the blood serum of patients.Materials and methods. There were determined the body mass, height, waist size, blood serum  lipid fraction (triglycerides, LPHD, calculated the body mass index and VOI in 19 patients with DM type 2 older then 50 years. There were determined the content of fatty acids (palmitic С16:0, stearin С18:0, oleic С18:1 and linoleic С18:2 in triglycerides using the method of liquid-gas chromatography.Results. Examined patients were separated into 3 groups according to VOI value. There was detected that the higher VOI values in patients with diabetes mellitus type 2 (upper tertile were associated with the most intensive unfavorable changes of the fatty-acid spectrum of triglyceride fraction in the blood serum at the expense of an increase of saturated palmitic and stearin fatty acids fraction and decrease of unsaturated oleic and linoleic acids content. There were revealed the correlations between VOI and the levels of saturated and unsaturated triglyceride fatty acids.Conclusion. The calculation of VOI in patients with DM type 2 can be the useful indicator of the lipid metabolism disorder, especially the deviations of triglyceride fatty-acid spectrum

  14. CD4+, CD8+, CD3+ cell counts and CD4+/CD8+ ratio among patients with mycobacterial diseases (leprosy, tuberculosis), HIV infections, and normal healthy adults: a comparative analysis of studies in different regions of India.

    Science.gov (United States)

    Hussain, Tahziba; Kulshreshtha, K K; Yadav, V S; Katoch, Kiran

    2015-01-01

    In this study, we estimated the CD4+, CD8+, CD3+ cell counts and the CD4/CD8 ratio among normal healthy controls (adults and children), leprosy patients (without any complications and during reactional states), TB patients (with and without HIV), and HIV-positive patients (early infection and full-blown AIDS) and correlated the changes with disease progression. In our study, it was observed that among adults, CD4+ cell counts ranged from 518-1098, CD8+ from 312-952, whereas CD4/CD8 ratio from 0.75-2.30. Among children, both CD4+ and CD8+ cells were more and the CD4/CD8 ratio varied from 0.91-3.17. With regard to leprosy patients, we observed that CD4+ and CD8+ cell counts were lower among PB (pauci-bacillary) and MB (multi-bacillary) patients. CD4/CD8 ratio was 0.99 ± 0.28 among PB patients while the ratio was lower, 0.78 ± 0.20, among MB patients. CD4+ cell counts were raised during RR (reversal reactions) and ENL (erythema nodosum leprosum) among the PB and MB patients whereas the CD8+ cell counts were lower among PB and MB patients. CD4/CD8 ratio doubled during reactional episodes of RR and ENL. Among the HIV-negative tuberculosis (TB) patients, both the CD4+ and CD8+ cell counts were found to be less and the CD4/CD8 ratio varied between 0.53-1.75. Among the HIV-positive TB patients and HIV-positive patients, both the CD4+ and CD8+ cells were very less and ratio drops significantly. In the initial stages of infection, as CD4+ counts drop, an increase in the CD8+ cell counts was observed and the ratio declines. In full-blown cases, CD4+ cell counts were very low, 3-4 to 54 cells, CD8+ cells from 12-211 and the ratio drops too low. This study is the first of its kind in this region of the country and assumes importance since no other study has reported the values of CD4+ and CD8+ T-lymphocyte counts among patients with mycobacterial diseases (leprosy and TB), HIV infections along with normal healthy individuals of the region, and correlation with clinical

  15. Atom counting with accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kutschera, Walter

    1995-01-01

    A brief review of the current status and some recent applications of accelerator mass spectrometry (AMS) are presented. Some connections to resonance ionization mass spectroscopy (RIS) as the alternate atom counting method are discussed

  16. Determination of phosphorus-32 in wet-digested plant leaves by Cerenkov counting

    International Nuclear Information System (INIS)

    Wahid, P.A.; Kamalam, N.V.; Sankar, S.J.

    1985-01-01

    A method of determination of 32 P activity in leaf samples by Cerenkov counting technique is described. The method involves wet digestion of oven-dried leaves with 1:1 nitric-perchloric acid mixture followed by transferring the digest into a scintillation counting vial with distilled water upto a final volume of 20 mL, and determining the activity in a liquid scintillation system. Reproducible count rates can be obtained if the vials are counted after 4h allowing the silica in the digest to settle. (author)

  17. Counting on dis-inhibition: a circuit motif for interval counting and selectivity in the anuran auditory system.

    Science.gov (United States)

    Naud, Richard; Houtman, Dave; Rose, Gary J; Longtin, André

    2015-11-01

    Information can be encoded in the temporal patterning of spikes. How the brain reads these patterns is of general importance and represents one of the greatest challenges in neuroscience. We addressed this issue in relation to temporal pattern recognition in the anuran auditory system. Many species of anurans perform mating decisions based on the temporal structure of advertisement calls. One important temporal feature is the number of sound pulses that occur with a species-specific interpulse interval. Neurons representing this pulse count have been recorded in the anuran inferior colliculus, but the mechanisms underlying their temporal selectivity are incompletely understood. Here, we construct a parsimonious model that can explain the key dynamical features of these cells with biologically plausible elements. We demonstrate that interval counting arises naturally when combining interval-selective inhibition with pulse-per-pulse excitation having both fast- and slow-conductance synapses. Interval-dependent inhibition is modeled here by a simple architecture based on known physiology of afferent nuclei. Finally, we consider simple implementations of previously proposed mechanistic explanations for these counting neurons and show that they do not account for all experimental observations. Our results demonstrate that tens of millisecond-range temporal selectivities can arise from simple connectivity motifs of inhibitory neurons, without recourse to internal clocks, spike-frequency adaptation, or appreciable short-term plasticity. Copyright © 2015 the American Physiological Society.

  18. Reconstruction of multiple-pinhole micro-SPECT data using origin ensembles.

    Science.gov (United States)

    Lyon, Morgan C; Sitek, Arkadiusz; Metzler, Scott D; Moore, Stephen C

    2016-10-01

    The authors are currently developing a dual-resolution multiple-pinhole microSPECT imaging system based on three large NaI(Tl) gamma cameras. Two multiple-pinhole tungsten collimator tubes will be used sequentially for whole-body "scout" imaging of a mouse, followed by high-resolution (hi-res) imaging of an organ of interest, such as the heart or brain. Ideally, the whole-body image will be reconstructed in real time such that data need only be acquired until the area of interest can be visualized well-enough to determine positioning for the hi-res scan. The authors investigated the utility of the origin ensemble (OE) algorithm for online and offline reconstructions of the scout data. This algorithm operates directly in image space, and can provide estimates of image uncertainty, along with reconstructed images. Techniques for accelerating the OE reconstruction were also introduced and evaluated. System matrices were calculated for our 39-pinhole scout collimator design. SPECT projections were simulated for a range of count levels using the MOBY digital mouse phantom. Simulated data were used for a comparison of OE and maximum-likelihood expectation maximization (MLEM) reconstructions. The OE algorithm convergence was evaluated by calculating the total-image entropy and by measuring the counts in a volume-of-interest (VOI) containing the heart. Total-image entropy was also calculated for simulated MOBY data reconstructed using OE with various levels of parallelization. For VOI measurements in the heart, liver, bladder, and soft-tissue, MLEM and OE reconstructed images agreed within 6%. Image entropy converged after ∼2000 iterations of OE, while the counts in the heart converged earlier at ∼200 iterations of OE. An accelerated version of OE completed 1000 iterations in <9 min for a 6.8M count data set, with some loss of image entropy performance, whereas the same dataset required ∼79 min to complete 1000 iterations of conventional OE. A combination of the two

  19. Sources and magnitude of sampling error in redd counts for bull trout

    Science.gov (United States)

    Jason B. Dunham; Bruce Rieman

    2001-01-01

    Monitoring of salmonid populations often involves annual redd counts, but the validity of this method has seldom been evaluated. We conducted redd counts of bull trout Salvelinus confluentus in two streams in northern Idaho to address four issues: (1) relationships between adult escapements and redd counts; (2) interobserver variability in redd...

  20. CoC Housing Inventory Count Reports

    Data.gov (United States)

    Department of Housing and Urban Development — Continuum of Care (CoC) Homeless Assistance Programs Housing Inventory Count Reports are a snapshot of a CoC’s housing inventory, available at the national and state...

  1. A Method for Counting Moving People in Video Surveillance Videos

    Directory of Open Access Journals (Sweden)

    Mario Vento

    2010-01-01

    Full Text Available People counting is an important problem in video surveillance applications. This problem has been faced either by trying to detect people in the scene and then counting them or by establishing a mapping between some scene feature and the number of people (avoiding the complex detection problem. This paper presents a novel method, following this second approach, that is based on the use of SURF features and of an ϵ-SVR regressor provide an estimate of this count. The algorithm takes specifically into account problems due to partial occlusions and to perspective. In the experimental evaluation, the proposed method has been compared with the algorithm by Albiol et al., winner of the PETS 2009 contest on people counting, using the same PETS 2009 database. The provided results confirm that the proposed method yields an improved accuracy, while retaining the robustness of Albiol's algorithm.

  2. A Method for Counting Moving People in Video Surveillance Videos

    Directory of Open Access Journals (Sweden)

    Conte Donatello

    2010-01-01

    Full Text Available People counting is an important problem in video surveillance applications. This problem has been faced either by trying to detect people in the scene and then counting them or by establishing a mapping between some scene feature and the number of people (avoiding the complex detection problem. This paper presents a novel method, following this second approach, that is based on the use of SURF features and of an -SVR regressor provide an estimate of this count. The algorithm takes specifically into account problems due to partial occlusions and to perspective. In the experimental evaluation, the proposed method has been compared with the algorithm by Albiol et al., winner of the PETS 2009 contest on people counting, using the same PETS 2009 database. The provided results confirm that the proposed method yields an improved accuracy, while retaining the robustness of Albiol's algorithm.

  3. A Method for Counting Moving People in Video Surveillance Videos

    Science.gov (United States)

    Conte, Donatello; Foggia, Pasquale; Percannella, Gennaro; Tufano, Francesco; Vento, Mario

    2010-12-01

    People counting is an important problem in video surveillance applications. This problem has been faced either by trying to detect people in the scene and then counting them or by establishing a mapping between some scene feature and the number of people (avoiding the complex detection problem). This paper presents a novel method, following this second approach, that is based on the use of SURF features and of an [InlineEquation not available: see fulltext.]-SVR regressor provide an estimate of this count. The algorithm takes specifically into account problems due to partial occlusions and to perspective. In the experimental evaluation, the proposed method has been compared with the algorithm by Albiol et al., winner of the PETS 2009 contest on people counting, using the same PETS 2009 database. The provided results confirm that the proposed method yields an improved accuracy, while retaining the robustness of Albiol's algorithm.

  4. Investigating Children's Abilities to Count and Make Quantitative Comparisons

    Science.gov (United States)

    Lee, Joohi; Md-Yunus, Sham'ah

    2016-01-01

    This study was designed to investigate children's abilities to count and make quantitative comparisons. In addition, this study utilized reasoning questions (i.e., how did you know?). Thirty-four preschoolers, mean age 4.5 years old, participated in the study. According to the results, 89% of the children (n = 30) were able to do rote counting and…

  5. Passive hand movements disrupt adults' counting strategies.

    Science.gov (United States)

    Imbo, Ineke; Vandierendonck, André; Fias, Wim

    2011-01-01

    In the present study, we experimentally tested the role of hand motor circuits in simple-arithmetic strategies. Educated adults solved simple additions (e.g., 8 + 3) or simple subtractions (e.g., 11 - 3) while they were required to retrieve the answer from long-term memory (e.g., knowing that 8 + 3 = 11), to transform the problem by making an intermediate step (e.g., 8 + 3 = 8 + 2 + 1 = 10 + 1 = 11) or to count one-by-one (e.g., 8 + 3 = 8…9…10…11). During the process of solving the arithmetic problems, the experimenter did or did not move the participants' hand on a four-point matrix. The results show that passive hand movements disrupted the counting strategy while leaving the other strategies unaffected. This pattern of results is in agreement with a procedural account, showing that the involvement of hand motor circuits in adults' mathematical abilities is reminiscent of finger counting during childhood.

  6. On temporal correlations in high-resolution frequency counting

    OpenAIRE

    Dunker, Tim; Hauglin, Harald; Rønningen, Ole Petter

    2016-01-01

    We analyze noise properties of time series of frequency data from different counting modes of a Keysight 53230A frequency counter. We use a 10 MHz reference signal from a passive hydrogen maser connected via phase-stable Huber+Suhner Sucoflex 104 cables to the reference and input connectors of the counter. We find that the high resolution gap-free (CONT) frequency counting process imposes long-term correlations in the output data, resulting in a modified Allan deviation that is characteristic...

  7. Pulse mode counting system with parallel port interface

    International Nuclear Information System (INIS)

    Farooq, M.A.; Mushtaq, N.; Sultan, M.; Karim, A.

    2010-11-01

    Pulse mode Counting System (PPCS) module has been designed and developed which is compatible with SPP (Standard Parallel Port) and EPP Enhanced Parallel Port). This system can capture, present and store real time data in a well formatted form. The stored data is in a format that can be imported in different packages for further analysis. The purpose of this system is to facilitate the research experiments having frequency range up to 4 MHz and storing range up to 16 million counts. (author)

  8. Generating ActiGraph counts from raw acceleration recorded by an alternative monitor

    DEFF Research Database (Denmark)

    Brønd, Jan Christian; Andersen, Lars Bo; Arvidsson, Daniel

    2017-01-01

    Introduction: Raw acceleration data collected by the ActiGraph accelerometer is aggregated using a proprietary method into arbitrary physical activity intensity units called counts, which has been extensively calibrated and validated against energy expenditure. Generating ActiGraph counts from any...... second across all rotational frequencies compared to the original ActiGraph method. Applying the aggregation method to the 24-hour free-living recordings resulted in an epoch level bias ranging from -16.2 to 0.9 counts per 10 second, a relative difference in the averaged physical activity (counts per...

  9. Pitch Counts in Youth Baseball and Softball: A Historical Review.

    Science.gov (United States)

    Feeley, Brian T; Schisel, Jessica; Agel, Julie

    2018-07-01

    Pitching injuries are getting increased attention in the mass media. Many references are made to pitch counts and the role they play in injury prevention. The original purpose of regulating the pitch count in youth baseball was to reduce injury and fatigue to pitchers. This article reviews the history and development of the pitch count limit in baseball, the effect it has had on injury, and the evidence regarding injury rates on softball windmill pitching. Literature search through PubMed, mass media, and organizational Web sites through June 2015. Pitch count limits and rest recommendations were introduced in 1996 after a survey of 28 orthopedic surgeons and baseball coaches showed injuries to baseball pitchers' arms were believed to be from the number of pitches thrown. Follow-up research led to revised recommendations with more detailed guidelines in 2006. Since that time, data show a relationship between innings pitched and upper extremity injury, but pitch type has not clearly been shown to affect injury rates. Current surveys of coaches and players show that coaches, parents, and athletes often do not adhere to these guidelines. There are no pitch count guidelines currently available in softball. The increase in participation in youth baseball and softball with an emphasis on early sport specialization in youth sports activities suggests that there will continue to be a rise in injury rates to young throwers. The published pitch counts are likely to positively affect injury rates but must be adhered to by athletes, coaches, and parents.

  10. Counting dyons in N=4 string theory

    CERN Document Server

    Dijkgraaf, R; Verlinde, Herman L

    1997-01-01

    We present a microscopic index formula for the degeneracy of dyons in four-dimensional N=4 string theory. This counting formula is manifestly symmetric under the duality group, and its asymptotic growth reproduces the macroscopic Bekenstein-Hawking entropy. We give a derivation of this result in terms of the type II five-brane compactified on K3, by assuming that its fluctuations are described by a closed string theory on its world-volume. We find that the degeneracies are given in terms of the denominator of a generalized super Kac-Moody algebra. We also discuss the correspondence of this result with the counting of D-brane states.

  11. Reviving common standards in point-count surveys for broad inference across studies

    Science.gov (United States)

    Matsuoka, Steven M.; Mahon, C. Lisa; Handel, Colleen M.; Solymos, Peter; Bayne, Erin M.; Fontaine, Patricia C.; Ralph, C.J.

    2014-01-01

    We revisit the common standards recommended by Ralph et al. (1993, 1995a) for conducting point-count surveys to assess the relative abundance of landbirds breeding in North America. The standards originated from discussions among ornithologists in 1991 and were developed so that point-count survey data could be broadly compared and jointly analyzed by national data centers with the goals of monitoring populations and managing habitat. Twenty years later, we revisit these standards because (1) they have not been universally followed and (2) new methods allow estimation of absolute abundance from point counts, but these methods generally require data beyond the original standards to account for imperfect detection. Lack of standardization and the complications it introduces for analysis become apparent from aggregated data. For example, only 3% of 196,000 point counts conducted during the period 1992-2011 across Alaska and Canada followed the standards recommended for the count period and count radius. Ten-minute, unlimited-count-radius surveys increased the number of birds detected by >300% over 3-minute, 50-m-radius surveys. This effect size, which could be eliminated by standardized sampling, was ≥10 times the published effect sizes of observers, time of day, and date of the surveys. We suggest that the recommendations by Ralph et al. (1995a) continue to form the common standards when conducting point counts. This protocol is inexpensive and easy to follow but still allows the surveys to be adjusted for detection probabilities. Investigators might optionally collect additional information so that they can analyze their data with more flexible forms of removal and time-of-detection models, distance sampling, multiple-observer methods, repeated counts, or combinations of these methods. Maintaining the common standards as a base protocol, even as these study-specific modifications are added, will maximize the value of point-count data, allowing compilation and

  12. An Economical Fast Discriminator for Nuclear Pulse Counting

    International Nuclear Information System (INIS)

    Issarachai, Opas; Punnachaiya, Suvit

    2009-07-01

    Full text: This research work was aimed to develop a fast discriminator at low cost but high capability for discrimination a nanosecond nuclear pulse. The fast discriminator can be used in association with fast photon counting system. The designed structure consisted of the ultra-fast voltage comparator using ADCMP601 integrated circuit, the monostable multivibrator with controllable pulse width output by propagation delay of logic gate, and the fast response buffer amplifier. The tested results of pulse height discrimination of 0-5 V nuclear pulse with 20 ns (FWHM) pulse width showed the correlation coefficient (R 2 ) between discrimination level and pulse height was 0.998, while the pulse rate more than 10 MHz could be counted. The 30 ns logic pulse width output revealed high stable and could be smoothly driven to low impedance load at 50 Ω. For pulse signal transmission to the counter, it was also found that the termination of reflected signal must be considered because it may cause pulse counting error

  13. Cache-Oblivious Planar Orthogonal Range Searching and Counting

    DEFF Research Database (Denmark)

    Arge, Lars; Brodal, Gerth Stølting; Fagerberg, Rolf

    2005-01-01

    present the first cache-oblivious data structure for planar orthogonal range counting, and improve on previous results for cache-oblivious planar orthogonal range searching. Our range counting structure uses O(Nlog2 N) space and answers queries using O(logB N) memory transfers, where B is the block...... size of any memory level in a multilevel memory hierarchy. Using bit manipulation techniques, the space can be further reduced to O(N). The structure can also be modified to support more general semigroup range sum queries in O(logB N) memory transfers, using O(Nlog2 N) space for three-sided queries...... and O(Nlog22 N/log2log2 N) space for four-sided queries. Based on the O(Nlog N) space range counting structure, we develop a data structure that uses O(Nlog2 N) space and answers three-sided range queries in O(logB N+T/B) memory transfers, where T is the number of reported points. Based...

  14. H I, galaxy counts, and reddening: Variation in the gas-to-dust ratio, the extinction at high galactic latitudes, and a new method for determining galactic reddening

    International Nuclear Information System (INIS)

    Burstein, D.; Heiles, C.

    1978-01-01

    We reanalyze the interrelationships among Shane-Wirtanen galaxy counts, H I column densities, and reddenings, and resolve many of the problems raised by Heiles. These problems were caused by two factors: subtle biases in the reddening data and a variable gas-to-dust ratio in the galaxy. We present a compilation of reddenings for RR Lyrae stars and globular clusters which are on the same system and which we believe to be relatively free of biases. The extinction at the galactic poles, as determined by galaxy counts, is reexamined by using a new method to analyze galaxy counts. This new method partially accounts for the nonrandom clustering of galaxies and permits a reasonable estimate of the error in log N/sub gal/ as a function of latitude. The analysis shows that the galaxy counts (or galaxy cluster counts) are too noisy to allow direct determination of the extinction, or variation in extinction, near the galactic poles. From all available data, we conclude that the reddening at the poles is small [< or =0.02 mag in E (B--V) over much of the north galactic pole] and irregularly distributed. We find that there are zero offsets in the relations between E (B--V) and H I, and between galaxy counts and H I, which are at least partly the result of an instrumental effect in the radio data. We also show that the gas-to-dust ratio can vary by a factor of 2 from the average, and we present two methods for correcting for this variability in predicting the reddening of objects which are located outside of the galactic absorbing layer. We present a prescription for predicting these reddenings; in the area of sky covered by the Shane-Wirtanen galaxy counts, the error in these predictions is, on average, less than 0.03 mag in E

  15. Automatic counting of microglial cell activation and its applications

    Directory of Open Access Journals (Sweden)

    Beatriz I Gallego

    2016-01-01

    Full Text Available Glaucoma is a multifactorial optic neuropathy characterized by the damage and death of the retinal ganglion cells. This disease results in vision loss and blindness. Any vision loss resulting from the disease cannot be restored and nowadays there is no available cure for glaucoma; however an early detection and treatment, could offer neuronal protection and avoid later serious damages to the visual function. A full understanding of the etiology of the disease will still require the contribution of many scientific efforts. Glial activation has been observed in glaucoma, being microglial proliferation a hallmark in this neurodegenerative disease. A typical project studying these cellular changes involved in glaucoma often needs thousands of images - from several animals - covering different layers and regions of the retina. The gold standard to evaluate them is the manual count. This method requires a large amount of time from specialized personnel. It is a tedious process and prone to human error. We present here a new method to count microglial cells by using a computer algorithm. It counts in one hour the same number of images that a researcher counts in four weeks, with no loss of reliability.

  16. Eutectic cell and nodule count as the quality factors of cast iron

    Directory of Open Access Journals (Sweden)

    E. Fraś

    2008-10-01

    Full Text Available In this work the predictions based on a theoretical analysis aimed at elucidating of eutectic cell count or nodule counts N wereexperimentally verified. The experimental work was focused on processing flake graphite and ductile iron under various inoculationconditions in order to achieve various physicochemical states of the experimental melts. In addition, plates of various wall thicknesses, s were cast and the resultant eutectic cell or nodule counts were established. Moreover, thermal analysis was used to find out the degree of maximum undercooling for the graphite eutectic, Tm. A relationship was found between the eutectic cell or nodule count and the maximum undercooling Tm.. In addition it was also found that N can be related to the wall thickness of plate shaped castings. Finally, the present work provides a rational for the effect of technological factors such as the melt chemistry, inoculation practice, and holding temperature and time on the resultant cell count or nodule count of cast iron. In particular, good agreement was found between the predictions of the theoretical analysis and the experimental data.

  17. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  18. Health Advocacy--Counting the Costs

    Science.gov (United States)

    Dyall, Lorna; Marama, Maria

    2010-01-01

    Access to, and delivery of, safe and culturally appropriate health services is increasingly important in New Zealand. This paper will focus on counting the costs of health advocacy through the experience of a small non government charitable organisation, the Health Advocates Trust, (HAT) which aimed to provide advocacy services for a wide range of…

  19. Concurrent non-deferred reference counting on the Microgrid: first experiences

    NARCIS (Netherlands)

    Herhut, S.; Joslin, C.; Scholz, S.-B.; Poss, R.; Grelck, C.

    2011-01-01

    We present a first evaluation of our novel approach for non- deferred reference counting on the Microgrid many-core architecture. Non-deferred reference counting is a fundamental building block of im- plicit heap management of functional array languages in general and Sin- gle Assignment C in

  20. How much do women count if they not counted?

    Directory of Open Access Journals (Sweden)

    Federica Taddia

    2006-01-01

    Full Text Available The condition of women throughout the world is marked by countless injustices and violations of the most fundamental rights established by the Universal Declaration of human rights and every culture is potentially prone to commit discrimination against women in various forms. Women are worse fed, more exposed to physical violence, more exposed to diseases and less educated; they have less access to, or are excluded from, vocational training paths; they are the most vulnerable among prisoners of conscience, refugees and immigrants and the least considered within ethnic minorities; from their very childhood, women are humiliated, undernourished, sold, raped and killed; their work is generally less paid compared to men’s work and in some countries they are victims of forced marriages. Such condition is the result of old traditions that implicit gender-differentiated education has long promoted through cultural models based on theories, practices and policies marked by discrimination and structured differentially for men and women. Within these cultural models, the basic educational institutions have played and still play a major role in perpetuating such traditions. Nevertheless, if we want to overcome inequalities and provide women with empowerment, we have to start right from the educational institutions and in particular from school, through the adoption of an intercultural approach to education: an approach based on active pedagogy and on methods of analysis, exchange and enhancement typical of socio-educational animation. The intercultural approach to education is attentive to promote the realisation of each individual and the dignity and right of everyone to express himself/herself in his/her own way. Such an approach will give women the opportunity to become actual agents of collective change and to get the strength and wellbeing necessary to count and be counted as human beings entitled to freedom and equality, and to have access to all