  1. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing

    Directory of Open Access Journals (Sweden)

    Biglino Giovanni

    2013-01-01

    Full Text Available Abstract Background Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930® is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. Methods The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm, keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient’s suitability for percutaneous pulmonary valve intervention. Results The distensibility of the material was identified in a range from 6.5 × 10-3 mmHg-1 for the 0.6 mm case, to 3.0 × 10-3 mmHg-1 for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Conclusion Values of distensibility, compared with literature data, show that Tango

  2. Optimal Scanning Protocols for Dual-Energy CT Angiography in Peripheral Arterial Stents: An in Vitro Phantom Study

    Directory of Open Access Journals (Sweden)

    Abdulrahman Almutairi

    2015-05-01

    Full Text Available Objective: To identify the optimal dual-energy computed tomography (DECT scanning protocol for peripheral arterial stents while achieving a low radiation dose, while still maintaining diagnostic image quality, as determined by an in vitro phantom study. Methods: Dual-energy scans in monochromatic spectral imaging mode were performed on a peripheral arterial phantom with use of three gemstone spectral imaging (GSI protocols, three pitch values, and four kiloelectron volts (keV ranges. A total of 15 stents of different sizes, materials, and designs were deployed in the phantom. Image noise, the signal-to-noise ratio (SNR, different levels of adaptive statistical iterative reconstruction (ASIR, and the four levels of monochromatic energy for DECT imaging of peripheral arterial stents were measured and compared to determine the optimal protocols. Results: A total of 36 scans with 180 datasets were reconstructed from a combination of different protocols. There was a significant reduction of image noise with a higher SNR from monochromatic energy images between 65 and 70 keV in all investigated preset GSI protocols (p < 0.05. In addition, significant effects were found from the main effect analysis for these factors: GSI, pitch, and keV (p = 0.001. In contrast, there was significant interaction on the unstented area between GSI and ASIR (p = 0.015 and a very high significant difference between keV and ASIR (p < 0.001. A radiation dose reduction of 50% was achieved. Conclusions: The optimal scanning protocol and energy level in the phantom study were GSI-48, pitch value 0.984, and 65 keV, which resulted in lower image noise and a lower radiation dose, but with acceptable diagnostic images.

  3. On the potential of a new IVUS elasticity modulus imaging approach for detecting vulnerable atherosclerotic coronary plaques: in vitro vessel phantom study.

    Science.gov (United States)

    Le Floc'h, Simon; Cloutier, Guy; Finet, Gérard; Tracqui, Philippe; Pettigrew, Roderic I; Ohayon, Jacques

    2010-10-07

    Peak cap stress amplitude is recognized as a good indicator of vulnerable plaque (VP) rupture. However, such stress evaluation strongly relies on a precise, but still lacking, knowledge of the mechanical properties exhibited by the plaque components. As a first response to this limitation, our group recently developed, in a previous theoretical study, an original approach, called iMOD (imaging modulography), which reconstructs elasticity maps (or modulograms) of atheroma plaques from the estimation of strain fields. In the present in vitro experimental study, conducted on polyvinyl alcohol cryogel arterial phantoms, we investigate the benefit of coupling the iMOD procedure with the acquisition of intravascular ultrasound (IVUS) measurements for detection of VP. Our results show that the combined iMOD-IVUS strategy: (1) successfully detected and quantified soft inclusion contours with high positive predictive and sensitivity values of 89.7 ± 3.9% and 81.5 ± 8.8%, respectively, (2) estimated reasonably cap thicknesses larger than ∼300 µm, but underestimated thinner caps, and (3) quantified satisfactorily Young's modulus of hard medium (mean value of 109.7 ± 23.7 kPa instead of 145.4 ± 31.8 kPa), but overestimated the stiffness of soft inclusions (mean Young`s moduli of 31.4 ± 9.7 kPa instead of 17.6 ± 3.4 kPa). All together, these results demonstrate a promising benefit of the new iMOD-IVUS clinical imaging method for in vivo VP detection.

  4. On the potential of a new IVUS elasticity modulus imaging approach for detecting vulnerable atherosclerotic coronary plaques: in vitro vessel phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Floc' h, Simon Le; Tracqui, Philippe; Ohayon, Jacques [Laboratory TIMC-DynaCell, UJF, CNRS UMR 5525, In3S, Grenoble (France); Cloutier, Guy [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Montreal, Quebec (Canada); Finet, Gerard [Department of Hemodynamics and Interventional Cardiology, Hospices Civils de Lyon and Claude Bernard University Lyon 1, INSERM Unit 886, Lyon (France); Pettigrew, Roderic I, E-mail: Guy.Cloutier@umontreal.c, E-mail: Jacques.Ohayon@imag.f [Laboratory of Integrative Cardiovascular Imaging Science, National Institute of Diabetes Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD (United States)

    2010-10-07

    Peak cap stress amplitude is recognized as a good indicator of vulnerable plaque (VP) rupture. However, such stress evaluation strongly relies on a precise, but still lacking, knowledge of the mechanical properties exhibited by the plaque components. As a first response to this limitation, our group recently developed, in a previous theoretical study, an original approach, called iMOD (imaging modulography), which reconstructs elasticity maps (or modulograms) of atheroma plaques from the estimation of strain fields. In the present in vitro experimental study, conducted on polyvinyl alcohol cryogel arterial phantoms, we investigate the benefit of coupling the iMOD procedure with the acquisition of intravascular ultrasound (IVUS) measurements for detection of VP. Our results show that the combined iMOD-IVUS strategy: (1) successfully detected and quantified soft inclusion contours with high positive predictive and sensitivity values of 89.7 {+-} 3.9% and 81.5 {+-} 8.8%, respectively, (2) estimated reasonably cap thicknesses larger than {approx}300 {mu}m, but underestimated thinner caps, and (3) quantified satisfactorily Young's modulus of hard medium (mean value of 109.7 {+-} 23.7 kPa instead of 145.4 {+-} 31.8 kPa), but overestimated the stiffness of soft inclusions (mean Young's moduli of 31.4 {+-} 9.7 kPa instead of 17.6 {+-} 3.4 kPa). All together, these results demonstrate a promising benefit of the new iMOD-IVUS clinical imaging method for in vivo VP detection.

  5. Image based cardiac acceleration map using statistical shape and 3D+t myocardial tracking models; in-vitro study on heart phantom

    Science.gov (United States)

    Pashaei, Ali; Piella, Gemma; Planes, Xavier; Duchateau, Nicolas; de Caralt, Teresa M.; Sitges, Marta; Frangi, Alejandro F.

    2013-03-01

    It has been demonstrated that the acceleration signal has potential to monitor heart function and adaptively optimize Cardiac Resynchronization Therapy (CRT) systems. In this paper, we propose a non-invasive method for computing myocardial acceleration from 3D echocardiographic sequences. Displacement of the myocardium was estimated using a two-step approach: (1) 3D automatic segmentation of the myocardium at end-diastole using 3D Active Shape Models (ASM); (2) propagation of this segmentation along the sequence using non-rigid 3D+t image registration (temporal di eomorphic free-form-deformation, TDFFD). Acceleration was obtained locally at each point of the myocardium from local displacement. The framework has been tested on images from a realistic physical heart phantom (DHP-01, Shelley Medical Imaging Technologies, London, ON, CA) in which the displacement of some control regions was known. Good correlation has been demonstrated between the estimated displacement function from the algorithms and the phantom setup. Due to the limited temporal resolution, the acceleration signals are sparse and highly noisy. The study suggests a non-invasive technique to measure the cardiac acceleration that may be used to improve the monitoring of cardiac mechanics and optimization of CRT.

  6. An In Vitro Study of a New Device: Evaluation of Novel Wide-Angle Lens Flexible Cystoscope Using Phantom Bladder Model.

    Science.gov (United States)

    Yamaguchi, Kunihisa; Inoue, Takamitsu; Habuchi, Tomonori; Inokuchi, Junichi; Yokomizo, Akira; Eto, Masatoshi; Kanayama, Hiro-Omi

    2017-10-01

    The features and usefulness of a novel wide-angle lens flexible cystoscope were assessed with a view to its practical application. A phantom bladder model, on which a total of 12 markers that resemble lesions were arranged, was created for this study. Twenty-six urologists at three institutions observed this phantom bladder model using a conventional flexible cystoscope and a novel wide-angle lens flexible cystoscope, and they compared the observation time, marker detection rate, number of misidentified marker locations, overlooked locations, and misidentified location sites of both devices. Specific observation procedures that make use of the features of a wide-angle lens flexible cystoscope were also investigated. The observation time tended to be shorter with the wide-angle lens cystoscope than with a conventional cystoscope (104.9 seconds vs 113.6 seconds, p = 0.123). The marker detection rate was higher with the wide-angle lens cystoscope (90.2% vs 85.1%, p = 0.005). The number of marker location misidentifications did not differ between the two devices. Using a specifically designed observation procedure with the wide-angle lens cystoscope tended to further improve the marker detection rate (91.4% vs 88.1%, p = 0.157). Compared with a conventional cystoscope, a wide-angle lens cystoscope improved the lesion detection rate and has the potential to reduce observation time. The novel wide-angle lens flexible cystoscope is regarded as a useful device that offers advantages not available with a conventional cystoscope.

  7. An in vitro phantom study on the influence of tear size and configuration on the hemodynamics of the lumina in chronic type B aortic dissections.

    Science.gov (United States)

    Rudenick, Paula A; Bijnens, Bart H; García-Dorado, David; Evangelista, Arturo

    2013-02-01

    Management and follow-up of chronic aortic dissections continue to be a clinical challenge due to progressive dilatation and subsequent rupture. To predict complications, guidelines suggest follow-up of aortic diameter. However, dilatation is triggered by hemodynamic parameters (pressures/wall shear stresses) and geometry of false (FL) and true lumen (TL), information not captured by diameter alone. Therefore, we aimed at better understanding the influence of dissection anatomy on TL and FL hemodynamics. In vitro studies were performed using pulsatile flow in realistic dissected latex/silicone geometries with varying tear number, size, and location. We assessed three different conformations: (1) proximal tear only; (2) distal tear only; (3) both proximal and distal tears. All possible combinations (n = 8) of small (10% of aortic diameter) and large (25% of aortic diameter) tears were considered. Pressure, velocity, and flow patterns were analyzed within the lumina (at proximal and distal sections) and at the tears. We also computed the FL mean pressure index (FPI(mean)%) as a percentage of the TL mean pressure, to compare pressures among models. The presence of large tears equalized FL/TL pressures compared with models with only small tears (proximal FPI(mean)% 99.85 ± 0.45 vs 92.73 ± 3.63; distal FPI(mean)% 99.51 ± 0.80 vs 96.35 ± 1.96; P 290 cm/s), and a well-defined flow. Additionally, both proximal and distal tears act as entry and exit. During systole, flow enters the FL through all tears simultaneously, while during diastole, flow leaves through all communications. Flow through the FL, from proximal to distal tears or vice versa, is minimal. Our results suggest that FL hemodynamics heavily depends on cumulative tear size, and thus, it is an important parameter to take into account when clinically assessing chronic aortic dissections. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  8. A comparative study on patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2015-01-01

    Full Text Available Purpose: To compare the results of patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom. Methods: Fifteen intensity modulated radiotherapy (IMRT plans already planned on treatment planning system (TPS for head-and-neck cancer patients were exported on all three kinds of phantoms viz. slab phantom, acrylic body phantom and goat head phantom, and dose was calculated using anisotropic analytic algorithm (AAA. All the gantry angles were set to zero in case of slab phantom while set to as it is in actual plan in case of other two phantoms. All the plans were delivered by linear accelerator (LA and dose for each plan was measured by 0.13 cc ion chamber. The percentage (% variations between planned and measured doses were calculated and analyzed. Results: The mean % variations between planned and measured doses of all IMRT quality assurance (QA plans were as 0.65 (Standard deviation (SD: 0.38 with confidence limit (CL 1.39, 1.16 (SD: 0.61 with CL 2.36 and 2.40 (SD: 0.86 with CL 4.09 for slab phantom, acrylic head phantom and goat head phantom respectively. Conclusion: Higher dose variations found in case of real tissue phantom compare to results in case of slab and acrylic body phantoms. The algorithm AAA does not calculate doses in heterogeneous medium as accurate as it calculates in homogeneous medium. Therefore the patient specific absolute dosimetry should be done using heterogeneous phantom mimicking density wise as well as design wise to the actual human body.  

  9. Validation study of the thorax phantom Lungman for optimization purposes

    Science.gov (United States)

    Rodríguez Pérez, Sunay; Marshall, Nicholas W.; Struelens, Lara; Bosmans, Hilde

    2017-03-01

    This work aims to investigate the advantages and limitations of the Kyoto Kagaku thorax phantom Lungman for use in chest radiography optimization studies. First, patient survey data were gathered for chest posterior anterior (PA) and lateral (LAT) examinations in a standard chest X-ray room over a period of one year, using a Caesium Iodide (CsI) based flat panel detector with automatic exposure control (AEC). Parameters surveyed included exposure index (EI), dose area product (DAP) and AEC exposure time. PA and LAT projections of the phantom were then compared to these values. Additionally, the equivalence in millimetres of poly (methyl methacrylate) (PMMA) was established for the different regions of the Lungman phantom (lungs and mediastinum). Finally, a voxel model of the Lungman phantom was developed by the segmentation of a volumetric dataset of the phantom acquired using CT scanning. Subsequently, the model was used in Monte Carlo simulations with PENELOPE/penEasy code to calculate the energy deposited in the organs of the phantom. This enabled comparison of the phantom tissue-equivalent materials with materials defined by ICRP 89 in terms of energy deposition. For the survey data, close agreement was found between phantom and the median values for the patient data (deviations ranged from 4% to 31%, one outlier). The phantom lung region is equivalent to 89 mm to 106 mm of PMMA, depending on tube voltage. Energy deposited in the phantom material compared to those for ICRP defined material differed by at most 36% in AP irradiations and 49% in PA irradiations.

  10. Pulse-wave propagation in straight-geometry vessels for stiffness estimation: theory, simulations, phantoms and in vitro findings.

    Science.gov (United States)

    Shahmirzadi, Danial; Li, Ronny X; Konofagou, Elisa E

    2012-11-01

    Pulse wave imaging (PWI) is an ultrasound-based method for noninvasive characterization of arterial stiffness based on pulse wave propagation. Reliable numerical models of pulse wave propagation in normal and pathological aortas could serve as powerful tools for local pulse wave analysis and a guideline for PWI measurements in vivo. The objectives of this paper are to (1) apply a fluid-structure interaction (FSI) simulation of a straight-geometry aorta to confirm the Moens-Korteweg relationship between the pulse wave velocity (PWV) and the wall modulus, and (2) validate the simulation findings against phantom and in vitro results. PWI depicted and tracked the pulse wave propagation along the abdominal wall of canine aorta in vitro in sequential Radio-Frequency (RF) ultrasound frames and estimates the PWV in the imaged wall. The same system was also used to image multiple polyacrylamide phantoms, mimicking the canine measurements as well as modeling softer and stiffer walls. Finally, the model parameters from the canine and phantom studies were used to perform 3D two-way coupled FSI simulations of pulse wave propagation and estimate the PWV. The simulation results were found to correlate well with the corresponding Moens-Korteweg equation. A high linear correlation was also established between PWV² and E measurements using the combined simulation and experimental findings (R² =  0.98) confirming the relationship established by the aforementioned equation.

  11. Motorized fusion guided prostate biopsy: phantom study

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Pinto, Peter; Wood, Bradford J.

    2017-03-01

    1, 2, and 3, respectively. The mechanical error was 0.75+/-0.4 mm, 0.45+/-0.4 mm, and 0.55+/-0.4 mm, for free hand approach while it was 1.0+/-0.57 mm, 0.45+/-0.4 mm, and 0.35+/-0.25 mm, for motorized approach, for target 1, 2, and 3, respectively. PPMCC remained almost at 1.0 for the motorized approach while having a variation between 0.9 and 1.0 for the free hand approach. Conclusions: motorized fusion guided prostate biopsy in a phantom study was feasible and non-inferior or comparable to the free hand manual approach in terms of accuracy and speed of targeting, while being superior in terms of repeatability and steadiness.

  12. Studies on Phantom Vibration and Ringing Syndrome among Postgraduate Students

    Directory of Open Access Journals (Sweden)

    Atul Kumar Goyal

    2015-03-01

    Full Text Available Phantom vibrations and ringing of mobile phones are prevalent hallucinations in the general population. They might be considered as a normal brain mechanism. The aim of this study was to establish the prevalence of Phantom vibrations and ringing syndrome among students and to assess factors associated it. The survey of 300 postgraduate students belonging to different field of specialization was conducted at Kurukshetra University. 74% of students were found to have both Phantom vibrations and ringing syndrome. Whereas 17% of students felt Phantom vibration exclusively and 4% students face only Phantom ringing syndrome. Both the syndrome occurs more fervent in students who kept their mobile phone in shirt or jean pocket than to who kept mobile in handbag. 75% of students felt vibration or ringing even when the phone is switched off or phone was not in their pocket. Also the frequency of both the syndrome is directly proportional to the duration of mobile phone use and person emotional behavior. Although most of students agree that the Phantom syndrome did not bother them but some students deals with anxiety when they feel symptoms associated with Phantom syndrome. By using mobile phones in proper way, one can avoid these syndromes, or at least can ameliorate the symptoms.

  13. A solid tissue phantom for photon migration studies

    Energy Technology Data Exchange (ETDEWEB)

    Cubeddu, Rinaldo; Pifferi, Antonio; Taroni, Paola; Torricelli, Alessandro; Valentini, Gianluca [CEQSE-CNR and Dipartimento di Fisica, Politecnico di Milano, Piazza L da Vinci 32, 20133 Milano (Italy)

    1997-10-01

    A solid tissue phantom made of agar, Intralipid and black ink is described and characterized. The preparation procedure is fast and easily implemented with standard laboratory equipment. An instrumentation for time-resolved transmittance measurements was used to determine the optical properties of the phantom. The absorption and the reduced scattering coefficients are linear with the ink and Intralipid concentrations, respectively. A systematic decrease of the reduced scattering coefficient dependent on the agar content is observed, but can easily be managed. The phantom is highly homogeneous and shows good repeatability among different preparations. Moreover, agar inclusions can be easily embedded in either solid or liquid matrixes, and no artefacts are caused by the solid - solid or solid - liquid interfaces. This allows one to produce reliable and realistic inhomogeneous phantoms with known optical properties, particularly interesting for studies on optical imaging through turbid media. (author)

  14. Evaluation of factors influencing arterial Doppler waveforms in an in vitro flow phantom

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Chang Kyu [Dept. of Radiology, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Kyoung Ho [Dept. of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); Kim, Seung Hyup [Dept. of Radiology and the Institute of Radiation Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-01-15

    The aim of this study was to investigate factors that influence arterial Doppler waveforms in an in vitro phantom to provide a more accurate and comprehensive explanation of the Doppler signal. A flow model was created using a pulsatile artificial heart, rubber or polyethylene tubes, a water tank, and a glass tube. Spectral Doppler tracings were obtained in multiple combinations of compliance, resistance, and pulse rate. Peak systolic velocity, minimum diastolic velocity, resistive index (RI), pulsatility index, early systolic acceleration time, and acceleration index were measured. On the basis of these measurements, the influences of the variables on the Doppler waveforms were analyzed. With increasing distal resistance, the RI increased in a relatively linear relationship. With increasing proximal resistance, the RI decreased. The pulsus tardus and parvus phenomenon was observed with a small acceleration index in the model with a higher grade of stenosis. An increase in the distal resistance masked the pulsus tardus and parvus phenomenon by increasing the acceleration index. Although this phenomenon occurred independently of compliance, changes in the compliance of proximal or distal tubes caused significant changes in the Doppler waveform. There was a reverse relationship between the RI and the pulse rate. Resistance and compliance can alter the Doppler waveforms independently. The pulse rate is an extrinsic factor that also influences the RI. The compliance and distal resistance, as well as proximal resistance, influence the pulsus tardus and parvus phenomenon.

  15. Phantom breast sensations and phantom breast pain : A 2-year prospective study and a methodological analysis of literature

    NARCIS (Netherlands)

    Dijkstra, P.U.; Rietman, J.S.; Geertzen, J.H.B.

    The first aim of this study was to assess prospectively the incidence of phantom breast sensations (PB sensations) and phantom breast pain (PB pain) in a sample of patients treated for breast cancer (n = 204) by means of a modified radical mastectomy (n = 82). Patients were assessed 6 weeks, 6, 12

  16. Phantom breast sensations and phantom breast pain: A 2-year prospective study and a methodological analysis of literature

    NARCIS (Netherlands)

    Dijkstra, P.U.; Rietman, Johan Swanik; Geertzen, J.H.B.

    The first aim of this study was to assess prospectively the incidence of phantom breast sensations (PB sensations) and phantom breast pain (PB pain) in a sample of patients treated for breast cancer (n = 204) by means of a modified radical mastectomy (n = 82). Patients were assessed 6 weeks, 6, 12

  17. The impact of anthropometric patient-phantom matching on organ dose: A hybrid phantom study for fluoroscopy guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Perry B.; Geyer, Amy; Borrego, David; Ficarrotta, Kayla; Johnson, Kevin; Bolch, Wesley E. [Nuclear and Radiological Engineering, University of Florida, Gainesville, Florida 32611 (United States); Radiology, University of Florida, Jacksonville, Florida 32209 (United States); Department of Nuclear and Radiological/Biomedical Engineering, University of Florida, Gainesville, Florida 32611-8300 (United States)

    2011-02-15

    Purpose: To investigate the benefits and limitations of patient-phantom matching for determining organ dose during fluoroscopy guided interventions. Methods: In this study, 27 CT datasets representing patients of different sizes and genders were contoured and converted into patient-specific computational models. Each model was matched, based on height and weight, to computational phantoms selected from the UF hybrid patient-dependent series. In order to investigate the influence of phantom type on patient organ dose, Monte Carlo methods were used to simulate two cardiac projections (PA/left lateral) and two abdominal projections (RAO/LPO). Organ dose conversion coefficients were then calculated for each patient-specific and patient-dependent phantom and also for a reference stylized and reference hybrid phantom. The coefficients were subsequently analyzed for any correlation between patient-specificity and the accuracy of the dose estimate. Accuracy was quantified by calculating an absolute percent difference using the patient-specific dose conversion coefficients as the reference. Results: Patient-phantom matching was shown most beneficial for estimating the dose to heavy patients. In these cases, the improvement over using a reference stylized phantom ranged from approximately 50% to 120% for abdominal projections and for a reference hybrid phantom from 20% to 60% for all projections. For lighter individuals, patient-phantom matching was clearly superior to using a reference stylized phantom, but not significantly better than using a reference hybrid phantom for certain fields and projections. Conclusions: The results indicate two sources of error when patients are matched with phantoms: Anatomical error, which is inherent due to differences in organ size and location, and error attributed to differences in the total soft tissue attenuation. For small patients, differences in soft tissue attenuation are minimal and are exceeded by inherent anatomical differences

  18. Phantom pain and phantom sensations in upper limb amputees : an epidemiological study

    NARCIS (Netherlands)

    Kooijman, CM; Dijkstra, PU; Geertzen, JHB; Elzinga, A; van der Schans, CP

    Phantom pain in subjects with an amputated limb is a well-known problem. However, estimates of the prevalence of phantom pain differ considerably in the literature. Various factors associated with phantom pain have been described including pain before the amputation, gender, dominance, and time

  19. Study of digital mammographic equipments by phantom image quality.

    Science.gov (United States)

    Mayo, P; Rodenas, F; Verdú, G; Campayo, J M; Villaescusa, J I

    2006-01-01

    Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast-detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is CDMAM 3.4. One of the most extended indexes to measure the image quality in an objective way is the image quality figure (IQF). The aim of this work is to study the image quality of different images contrast-detail phantom CDMAM 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments that facilitates the evaluation of image contrast and detail resolution.

  20. A dosimetric study on slab-pinewood-slab phantom for developing the heterogeneous chest phantom mimicking actual human chest

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2017-01-01

    Full Text Available The aim is to study the density, isodose depths, and doses at different points in slab-pinewood-slab (SPS phantom, solid phantom SP34 (made up of polystyrene, and chest level of actual patient for developing heterogeneous chest phantom mimicking thoracic region of human body. A 6 MV photon beam of field size of 10 cm×10 cm was directed perpendicular to the surface of computed tomography (CT images of chest level of patient, SPS phantom, and SP34 phantom. Dose was calculated using anisotropic analytical algorithm. Hounsfield units were used to calculate the density of each medium. Isodose depths in all the three sets of CT images were measured. Variations between planned doses on treatment planning system (TPS and measured on linear accelerator (LA were calculated for three points, namely, near slab-pinewood interfaces (6 and 18 cm depths and 10 cm depth in SPS phantom and at the same depths in SP34 phantom. Density of pinewood, SP34 slabs, chest wall, lung, and soft tissue behind lung was measured as 0.329 ± 0.08, 0.999 ± 0.02, 0.898 ± 0.02, 0.291 ± 0.12, and 1.002 ± 0.03 g/cc, respectively. Depths of 100% and 90% isodose curves in all the three sets of CT images were found to be similar. Depths of 80%, 70%, 60%, 50%, and 40% isodose lines in SPS phantom images were found to be equivalent to that in chest images, while it was least in SP34 phantom images. Variations in doses calculated at 6, 10, and 18 cm depths on TPS and measured on LA were found to be 0.36%, 1.65%, and 2.23%, respectively, in case of SPS phantom, while 0.24%, 0.90%, and 0.93%, respectively, in case of SP34 slab phantom. SPS phantom seemed equivalent to the chest level of human body. Dosimetric results of this study indicate that patient-specific quality assurance can be done using chest phantom mimicking thoracic region of human body, which has been fabricated using polystyrene and pinewood.

  1. Posttraumatic syringomyelia: volumetric phantom and patient studies using MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Freund, Michael; Habicht, Dirk; Kalvine, Kira; Sartor, Klaus [Department of Neuroradiology, Medical School, University of Heidelberg (Germany); Aschoff, Alfred [Department of Neurosurgery, Medical School, University of Heidelberg (Germany)

    2002-12-01

    The purpose of this study was to determine the volume of posttraumatic syringomyelia (PTS) based on standard MRI data acquisitions, and to compare the volumes with the neurological deficits of the patients. Firstly, phantom studies were performed using routine T1- (T1W; TR 500 ms, TE 13 ms) spin-echo (SE) images, 3D gradient-echo (GE) images and T2-weighted (T2W) turbo spin-echo (TSE) images (TR 3000 ms, TE 130 ms), in the sagittal plane. The slices were interleaved so that there was no gap. Twelve phantoms simulating a PTS were constructed and filled with fluid. Each volume was exactly measured immediately prior to filling (volumes: 3600-74,000 mm{sup 3}, mean 27,500 mm{sup 3}). In the clinical study 32 patients with PTS were examined using the same protocol. Patients were supine and a phased-array coil was used. The phantom studies revealed measurement errors of within 35%. There were problems defining the boundaries in the small and irregular phantoms as well as in small and irregular PTS, and due to the partial-volume averaging effect. The two small irregular phantoms could only be measured on the axial images. The T2W images in the axial plane showed the best results: measurement accuracy 92%. In the clinical study all examinations were technically successful. The volumes of the PTS ranged between 200 and 19,800 mm{sup 3}; the mean volume was 4075 mm{sup 3}. Our initial results show that the volume measurement of a PTS using standard MRI sequences can help generate more objective and accurate measures of spinal cord lesions, and this may enhance the sensitivity of MRI in detecting disease progression or regression after treatment. (orig.)

  2. Axial transmission method for long bone fracture evaluation by ultrasonic guided waves: simulation, phantom and in vitro experiments.

    Science.gov (United States)

    Xu, Kailiang; Ta, Dean; He, Runxin; Qin, Yi-Xian; Wang, Weiqi

    2014-04-01

    Mode conversion occurs when the ultrasonic guided waves encounter fractures. The aim of this study was to investigate the feasibility of fracture assessment in long cortical bone using guided-mode conversion. Mode conversion behavior between the fundamental modes S0 and A0 was analyzed. The expressions proposed for modal velocity were used to identify the original and converted modes. Simulations and phantom experiments were performed using 1.0-mm-thick steel plates with a notch width of 0.5 mm and notch depths of 0.2, 0.4, 0.6 and 0.8 mm. Furthermore, in vitro experiments were carried out on nine ovine tibias with 1.0-mm-wide partial transverse gap break and cortical thickness varying from 2.10 to 3.88 mm. The study confirmed that mode conversion gradually becomes observable as fracture depth increases. Energy percentages of the converted modes correlated strongly with fracture depth, as illustrated by the frequency-sweeping experiments on steel phantoms (100-1100 kHz, r(2) = 0.97, p < 0.0069) and the fixed-frequency experiments on nine ovine tibias (250 kHz, r(2) = 0.97, p < 0.0056). The approaches described, including mode excitation, velocity expressions and energy percentage criteria, may also contribute to ultrasonic monitoring of long bone fracture healing. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Experimental and computational development of a natural breast phantom for dosimetry studies

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Luciana B.; Campos, Tarcisio P.R., E-mail: lucibn19@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2013-07-01

    This paper describes the experimental and computational development of a natural breast phantom, anthropomorphic and anthropometric for studies in dosimetry of brachytherapy and teletherapy of breast. The natural breast phantom developed corresponding to fibroadipose breasts of women aged 30 to 50 years, presenting radiographically medium density. The experimental breast phantom was constituted of three tissue-equivalents (TE's): glandular TE, adipose TE and skin TE. These TE's were developed according to chemical composition of human breast and present radiological response to exposure. Completed the construction of experimental breast phantom this was mounted on a thorax phantom previously developed by the research group NRI/UFMG. Then the computational breast phantom was constructed by performing a computed tomography (CT) by axial slices of the chest phantom. Through the images generated by CT a computational model of voxels of the thorax phantom was developed by SISCODES computational program, being the computational breast phantom represented by the same TE's of the experimental breast phantom. The images generated by CT allowed evaluating the radiological equivalence of the tissues. The breast phantom is being used in studies of experimental dosimetry both in brachytherapy as in teletherapy of breast. Dosimetry studies by MCNP-5 code using the computational model of the phantom breast are in progress. (author)

  4. iPads in Breast Imaging - A Phantom Study.

    Science.gov (United States)

    Hammon, M; Schlechtweg, P M; Schulz-Wendtland, R; Uder, M; Schwab, S A

    2014-02-01

    Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as "uncertain", correct 2 : 1 decisions were classified as "uncertain/readable". In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of "uncertain" fields did not show significant differences. The number of "uncertain" fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of "uncertain/readable" fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens.

  5. iPads in Breast Imaging – A Phantom Study

    Science.gov (United States)

    Hammon, M.; Schlechtweg, P. M.; Schulz-Wendtland, R.; Uder, M.; Schwab, S. A.

    2014-01-01

    Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as “uncertain”, correct 2 : 1 decisions were classified as “uncertain/readable”. In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of “uncertain” fields did not show significant differences. The number of “uncertain” fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of “uncertain/readable” fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens. PMID:24741126

  6. Study of homogeneity and inhomogeneity phantom in CUDA EGS for small field dosimetry

    Science.gov (United States)

    Yani, Sitti; Rhani, Mohamad Fahdillah; Haryanto, Freddy; Arif, Idam

    2017-02-01

    CUDA EGS was CUDA implementation to simulate transport photon in a material based on Monte Carlo algorithm for X-ray imaging. The objective of this study was to investigate the effect of inhomogeneities in inhomogeneity phantom for small field dosimetry (1×1, 2×2, 3×3, 4×4 and 5×5 cm2). Two phantoms, homogeneity and inhomogeneity phantom were used. The interaction in homogeneity and inhomogeneity phantom was dominated by Compton interaction and multiple scattering. The CUDA EGS can represent the inhomogeneity effect in small field dosimetry by combining the grayscale curve between homogeneity and inhomogeneity phantom. The grayscale curve in inhomogeneity phantom is not asymmetric because of the existence of different material in phantom.

  7. A suitability study of the fission product phantom and the bottle manikin absorption phantom for calibration of in vivo bioassay equipment for the DOELAP accreditation testing program

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, P.C.; Lynch, T.P.

    1991-08-01

    Pacific Northwest laboratory (PNL) conducted an intercomparison study of the Fission Product phantom and the bottle manikin absorption (BOMAB) phantom for the US Department of Energy (DOE) to determine the consistency of calibration response of the two phantoms and their suitability for certification and use under a planned bioassay laboratory accreditation program. The study was initiated to determine calibration factors for both types of phantoms and to evaluate the suitability of their use in DOE Laboratory Accreditation Program (DOELAP) round-robin testing. The BOMAB was found to be more appropriate for the DOELAP testing program. 9 refs., 9 figs., 9 tabs.

  8. Myocardial defect detection using PET-CT: phantom studies.

    Directory of Open Access Journals (Sweden)

    Eugene S Mananga

    Full Text Available It is expected that both noise and activity distribution can have impact on the detectability of a myocardial defect in a cardiac PET study. In this work, we performed phantom studies to investigate the detectability of a defect in the myocardium for different noise levels and activity distributions. We evaluated the performance of three reconstruction schemes: Filtered Back-Projection (FBP, Ordinary Poisson Ordered Subset Expectation Maximization (OP-OSEM, and Point Spread Function corrected OSEM (PSF-OSEM. We used the Channelized Hotelling Observer (CHO for the task of myocardial defect detection. We found that the detectability of a myocardial defect is almost entirely dependent on the noise level and the contrast between the defect and its surroundings.

  9. Elasto-mammography: Theory, Algorithm, and Phantom Study

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available A new imaging modality framework, called elasto-mammography, is proposed to generate the elastograms of breast tissues based on conventional X-ray mammography. The displacement information is extracted from mammography projections before and after breast compression. Incorporating the displacement measurement, an elastography reconstruction algorithm is specifically developed to estimate the elastic moduli of heterogeneous breast tissues. Case studies with numerical breast phantoms are conducted to demonstrate the capability of the proposed elasto-mammography. Effects of noise with measurement, geometric mismatch, and elastic contrast ratio are evaluated in the numerical simulations. It is shown that the proposed methodology is stable and robust for characterization of the elastic moduli of breast tissues from the projective displacement measurement.

  10. Can nontriggered thoracic CT be used for coronary artery calcium scoring? A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xueqian [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9700RB Groningen, The Netherlands and Center for Medical Imaging – North East Netherlands, Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9700RB Groningen (Netherlands); Greuter, Marcel J. W. [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9700RB Groningen (Netherlands); Groen, Jaap M. [Department of Radiology, Zaans Medical Center, 1500EE Zaandam (Netherlands); Bock, Geertruida H. de [Department of Epidemiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9700RB Groningen (Netherlands); Oudkerk, Matthijs [Center for Medical Imaging – North East Netherlands, Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9700RB Groningen (Netherlands); Jong, Pim A. de [Department of Radiology, University Medical Center Utrecht, University of Utrecht, 3584CX Utrecht (Netherlands); Vliegenthart, Rozemarijn [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9700RB Groningen, The Netherlands and Center for Medical Imaging – North East Netherlands, Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9700RB Groningen (Netherlands)

    2013-08-15

    Purpose: Coronary artery calcium score, traditionally based on electrocardiography (ECG)-triggered computed tomography (CT), predicts cardiovascular risk. However, nontriggered CT is extensively utilized. The study-purpose is to evaluate the in vitro agreement in coronary calcium score between nontriggered thoracic CT and ECG-triggered cardiac CT.Methods: Three artificial coronary arteries containing calcifications of different densities (high, medium, and low), and sizes (large, medium, and small), were studied in a moving cardiac phantom. Two 64-detector CT systems were used. The phantom moved at 0–90 mm/s in nontriggered low-dose CT as index test, and at 0–30 mm/s in ECG-triggered CT as reference. Differences in calcium scores between nontriggered and ECG-triggered CT were analyzed by t-test and 95% confidence interval. The sensitivity to detect calcification was calculated as the percentage of positive calcium scores.Results: Overall, calcium scores in nontriggered CT were not significantly different to those in ECG-triggered CT (p > 0.05). Calcium scores in nontriggered CT were within the 95% confidence interval of calcium scores in ECG-triggered CT, except predominantly at higher velocities (≥50 mm/s) for the high-density and large-size calcifications. The sensitivity for a nonzero calcium score was 100% for large calcifications, but 46%± 11% for small calcifications in nontriggered CT.Conclusions: When performing multiple measurements, good agreement in positive calcium scores is found between nontriggered thoracic and ECG-triggered cardiac CT. Agreement decreases with increasing coronary velocity. From this phantom study, it can be concluded that a high calcium score can be detected by nontriggered CT, and thus, that nontriggered CT likely can identify individuals at high risk of cardiovascular disease. On the other hand, a zero calcium score in nontriggered CT does not reliably exclude coronary calcification.

  11. Human phantom

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    This human phantom has been received by CERN on loan from the State Committee of the USSR for the Utilization of Atomic Energy. It is used by the Health Physics Group to study personel radiation doses near the accelerators.

  12. Factors associated with phantom limb pain : a 31/2-year prospective study

    NARCIS (Netherlands)

    Bosmans, J.C.; Geertzen, J.H.B.; Post, W.J.; van der Schans, C.P.; Dijkstra, P.U.

    Objective: To analyse the prevalence of phantom (limb) pain over time and to analyse factors associated with phantom (limb) pain in a prospective cohort of amputees. Design: A multicentre longitudinal study. Patients: One hundred and thirty-four patients scheduled for amputation were included.

  13. Quadrature Slotted Surface Coil Pair for Magnetic Resonance Imaging at 4 Tesla: Phantom Study

    Directory of Open Access Journals (Sweden)

    Solis S.E.

    2012-01-01

    Full Text Available A coil array was composed of two slotted surface coils forming a structure with two plates at 900, each one having 6 circular slots and is introduced in this paper. Numerical simulations of the magnetic field of this coil array were performed at 170 MHz using the finite element method to study its behaviour. This coil array was developed for brain magnetic resonance imaging to be operated at the resonant frequency of 170 MHz in the transceiver mode and quadrature driven. Numerical simulations demonstrated that electromagnetic interaction between the coil elements is negligible, and that the magnetic field showed a good uniformity. Phantom images were acquired with our coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. In vitro images showed the feasibility of this coil array for standard pulses and high field magnetic resonance imaging.

  14. A study of partial volume effect on SPECT imaging using myocardial phantom. With HCM (ASH) model myocardial phantom

    Energy Technology Data Exchange (ETDEWEB)

    Onoguchi, Masahisa [Kanazawa Univ. (Japan). School of Medicine

    1997-05-01

    In order to evaluate simultaneously both myocardial perfusion and regional wall motion using ECG-gated myocardial SPECT imaging, correction for the partial volume effect (PVE) should be performed. For the quantitative analysis of myocardial SPECT imaging in patients with hypertrophic cardiomyopathy (HCM), we formed a new phantom simulating HCM with various septal wall thicknesses and estimated PVE using the recovery coefficient (RC). The value of RC in all phantoms increased with increasing thickness of the septal wall reaching a plateau at 25 mm for the cylindrical phantom and 25 mm for the Ep-phantom. Compared with the RC value, the PMMA-phantom had little influence on PVE. Therefore, our results suggested that the count in the septal wall could be underestimated if PVE was corrected by the value obtained for the cylindrical phantom. In conclusion, our new phantom simulating HCM was useful in assessing PVE in the hypertrophic septal wall. (author)

  15. Dosimetric comparison of tools for intensity modulated radiation therapy with gamma analysis: a phantom study

    Science.gov (United States)

    Akbas, Ugur; Okutan, Murat; Demir, Bayram; Koksal, Canan

    2015-07-01

    Dosimetry of the Intensity Modulated Radiation Therapy (IMRT) is very important because of the complex dose distributions. Diode arrays are the most common and practical measurement tools for clinical usage for IMRT. Phantom selection is critical for QA process. IMRT treatment plans are recalculated for the phantom irradiation in QA. Phantoms are made in different geometrical shapes to measure the doses of different types of irradiation techniques. Comparison of measured and calculated dose distributions for IMRT can be made by using gamma analysis. In this study, 10 head-and-neck IMRT QA plans were created with Varian Eclipse 8.9 treatment planning system. Water equivalent RW3-slab phantoms, Octavius-2 phantom and PTW Seven29 2D-array were used for QA measurements. Gantry, collimator and couch positions set to 00 and QA plans were delivered to RW3 and Octavius phantoms. Then the positions set to original angles and QA plans irradiated again. Measured and calculated fluence maps were evaluated with gamma analysis for different DD and DTA criteria. The effect of different set-up conditions for RW3 and Octavius phantoms in QA plan delivery evaluated by gamma analysis. Results of gamma analysis show that using RW3-slab phantoms with setting parameters to 00 is more appropriate for IMRT QA.

  16. Factors associated with phantom limb pain: a 31/2-year prospective study.

    Science.gov (United States)

    Bosmans, Joline C; Geertzen, Jan H B; Post, Wendy J; van der Schans, Cees P; Dijkstra, Pieter U

    2010-05-01

    To analyse the prevalence of phantom (limb) pain over time and to analyse factors associated with phantom (limb) pain in a prospective cohort of amputees. A multicentre longitudinal study. One hundred and thirty-four patients scheduled for amputation were included. Patients filled in questionnaires before amputation, and postal questionnaires six months, 1(1/2) years and 2(1/2) years to a maximum of 3(1/2) years after amputation. Preoperative assessment included patients' characteristics, date, side and level of, and reason for amputation. The follow-up questionnaires assessed the frequencies of the experienced phantom pain, prosthetic use and walking distance. The occurrence of phantom pain was defined as phantom pain a few times a day or more frequently. Pre- and postoperative questionnaires were available filled in by 85 amputees (33 females and 52 males). The percentage of lower limb amputees with phantom pain was the highest at six months after amputation, and of upper limb amputees at 1(1/2) years. In general, more women than men experienced phantom pain. One and a half years and 2(1/2) years after amputation the highest percentages of the lower limb amputees used their prosthesis more than 4 hours a day (66%), after that time this percentage decreased to 60%. The results of the two-level logistic regression analysis to predict phantom pain show that phantom pain was less frequently present in men (odds ratio (OR) = 0.12), in lower limb amputees (OR = 0.14) and that it decreased in due course (OR = 0.53 for 1 year). Protective factors for phantom pain are: being male, having a lower limb amputation and the time elapsed since amputation.

  17. Radiation protection to the eye and thyroid during diagnostic cerebral angiography: a phantom study.

    LENUS (Irish Health Repository)

    Shortt, C P

    2008-08-01

    We measured radiation doses to the eye and thyroid during diagnostic cerebral angiography to assess the effectiveness of bismuth and lead shields at dose reduction. Phantom head angiographic studies were performed with bismuth (study 1) and lead shields (study 2). In study 1 (12 phantoms), thermoluminescent dosimeters (TLD) were placed over the eyes and thyroid in three groups: (i) no shields (four phantoms); (ii) anterior bismuth shields (four phantoms) and (iii) anterior and posterior bismuth shields (four phantoms). In a second study (eight phantoms), lead shields were placed over the thyroid only and TLD dose measurements obtained in two groups: (i) no shielding (four phantoms) and (ii) thyroid lead shielding (four phantoms). A standard 4-vessel cerebral angiogram was performed on each phantom. Study 1 (bismuth shields) showed higher doses to the eyes compared with thyroid (mean 13.03 vs 5.98 mSv, P < 0.001) and a higher eye dose on the X-ray tube side. Overall, the use of bismuth shielding did not significantly reduce dose to either eyes or thyroid in the measured TLD positions. In study 2, a significant thyroid dose reduction was found with the use of lead shields (47%, mean 2.46 vs 4.62 mSv, P < 0.001). Considerable doses to the eyes and thyroid highlight the need for increased awareness of patient protection. Eye shielding is impractical and interferes with diagnostic capability. Thyroid lead shielding yields significant protection to the thyroid, is not in the field of view and should be used routinely.

  18. A computed tomography phantom study of foam earplugs

    Science.gov (United States)

    Hsu, Li-Sheng; Yen, Ju-Bei; Wang, Shie-Shan; Liao, Chien-Lin

    2016-01-01

    Abstract Ingestion of a foreign body is common among children. However, ingestion of foam earplugs (FEPs) has not been reported previously. A 7-month-old female infant presented with small bowel obstruction, which was finally proved to be a case of FEP ingestion. Computed tomography (CT) phantom study was performed to examine the imaging features of FEPs. We studied the following dry and fully wet FEPs, FEPs squeezed in pure water to varying degrees, and FEPs with different degrees of compression in the dry and wet states from day 0 to 6 and all scanned with a CT scanner. The density of a dry FEP is −843.5 ± 4.5 Hounsfield units (HU) and it increases to 0.76 ± 9.3 HU when fully wet. The densities of FEPs ranged from −844.2 to 1.0 HU with different water/air ratios, and some showed a heterogeneous geographic pattern. The densities of FEPs increase due to compression and gradual water absorption. FEPs can be potentially hazardous objects to children. Owing to the special foam structure of the FEP, it can mimic a fatty lesion if the density ranges from −100 to −50 HU; moreover, it can hide in the water if fully wet. However, it should not be mistaken as air, as the density of a dry FEP is −843.5 HU, and the contour can be observed if the window level is set appropriately. Because of its soft texture, the surgeon should be careful not to miss an FEP during the operation. Moreover, radiologists should be familiar with the CT features of FEPs so that they can be identified before surgery. PMID:27583901

  19. Balloon sheaths for gastrointestinal guidance and access: a preliminary phantom study

    Energy Technology Data Exchange (ETDEWEB)

    He, Xu; Shin, Ji Hoon; Kim, Hyo Cheol; Woo, Cheol Woong; Woo, Sung Ha; Choi, Won Chan; Kim, Jong Gyu; Lim, Jin Oh; Kim, Tae Hyung; Yoon, Chang Jin; Song, Ho Young [Univerisyt of Ulsan College of Medicine, Seoul (Korea, Republic of); Kang, Wee Chang [Daejeon University, Daejeon (Korea, Republic of)

    2005-09-15

    We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group II was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded. Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms ({rho} < 0.001). A significant difference was also found between group III and IV for both phantoms ({rho} < 0.001). The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body.

  20. Radiation-force-based estimation of acoustic attenuation using harmonic motion imaging (HMI) in phantoms and in vitro livers before and after HIFU ablation.

    Science.gov (United States)

    Chen, Jiangang; Hou, Gary Y; Marquet, Fabrice; Han, Yang; Camarena, Francisco; Konofagou, Elisa

    2015-10-07

    Acoustic attenuation represents the energy loss of the propagating wave through biological tissues and plays a significant role in both therapeutic and diagnostic ultrasound applications. Estimation of acoustic attenuation remains challenging but critical for tissue characterization. In this study, an attenuation estimation approach was developed using the radiation-force-based method of harmonic motion imaging (HMI). 2D tissue displacement maps were acquired by moving the transducer in a raster-scan format. A linear regression model was applied on the logarithm of the HMI displacements at different depths in order to estimate the acoustic attenuation. Commercially available phantoms with known attenuations (n = 5) and in vitro canine livers (n = 3) were tested, as well as HIFU lesions in in vitro canine livers (n = 5). Results demonstrated that attenuations obtained from the phantoms showed a good correlation (R² = 0.976) with the independently obtained values reported by the manufacturer with an estimation error (compared to the values independently measured) varying within the range of 15-35%. The estimated attenuation in the in vitro canine livers was equal to 0.32   ±   0.03 dB cm(-1) MHz(-1), which is in good agreement with the existing literature. The attenuation in HIFU lesions was found to be higher (0.58   ±   0.06 dB cm(-1) MHz(-1)) than that in normal tissues, also in agreement with the results from previous publications. Future potential applications of the proposed method include estimation of attenuation in pathological tissues before and after thermal ablation.

  1. Radiation-force-based estimation of acoustic attenuation using harmonic motion imaging (HMI) in phantoms and in vitro livers before and after HIFU ablation

    Science.gov (United States)

    Chen, Jiangang; Hou, Gary Y.; Marquet, Fabrice; Han, Yang; Camarena, Francisco; Konofagou, Elisa

    2015-10-01

    Acoustic attenuation represents the energy loss of the propagating wave through biological tissues and plays a significant role in both therapeutic and diagnostic ultrasound applications. Estimation of acoustic attenuation remains challenging but critical for tissue characterization. In this study, an attenuation estimation approach was developed using the radiation-force-based method of harmonic motion imaging (HMI). 2D tissue displacement maps were acquired by moving the transducer in a raster-scan format. A linear regression model was applied on the logarithm of the HMI displacements at different depths in order to estimate the acoustic attenuation. Commercially available phantoms with known attenuations (n=5 ) and in vitro canine livers (n=3 ) were tested, as well as HIFU lesions in in vitro canine livers (n=5 ). Results demonstrated that attenuations obtained from the phantoms showed a good correlation ({{R}2}=0.976 ) with the independently obtained values reported by the manufacturer with an estimation error (compared to the values independently measured) varying within the range of 15-35%. The estimated attenuation in the in vitro canine livers was equal to 0.32   ±   0.03 dB cm-1 MHz-1, which is in good agreement with the existing literature. The attenuation in HIFU lesions was found to be higher (0.58   ±   0.06 dB cm-1 MHz-1) than that in normal tissues, also in agreement with the results from previous publications. Future potential applications of the proposed method include estimation of attenuation in pathological tissues before and after thermal ablation.

  2. Anxiety and depression in patients with amputated limbs suffering from phantom pain: A comparative study with non-phantom chronic pain

    Directory of Open Access Journals (Sweden)

    Hadi Kazemi

    2013-01-01

    Conclusion : Our results indicate that depression and anxiety are not more common in PLP patients, whereas they are more prevalent in subjects with non-phantom chronic pain. These lower levels of anxiety and depression in PLP compared with chronic pain is a new finding that needs to be evaluated further, which may lead to new insights into the pathogenesis of phantom pain in further studies.

  3. Phantom limb pain relief by contralateral myofascial injection with local anaesthetic in a placebo-controlled study: preliminary results.

    Science.gov (United States)

    Casale, Roberto; Ceccherelli, Francesco; Labeeb, Alaa Abd Elaziz Mohamed; Biella, Gabriele E M

    2009-05-01

    To ascertain the existence of contralateral painful muscle areas mirroring phantom pain and to evaluate the short-term effects of anaesthetic vs saline, injected contra notlaterally to control phantom and phantom limb pain. Double-blinded cross-over study. Inpatients; rehabilitation institute. Eight lower limb amputees with phantom limb pain in the past 6 months. Either 1 ml of 0.25% bupivacaine or 0.9% saline injected alternately in each point with a 28-gauge needle, with 72 h between injections. Main outcome measurePhantom sensation modification and the intensity of phantom limb pain (visual analogue scale) before and after injections. Although present, painful muscle areas in the healthy limb do not mirror the topographical distribution of phantom limb pain. Sixty minutes after the injection, a statistically significant greater relief of phantom limb pain was observed after using local anaesthetic than when using saline injection (p = 0.003). Bupivacaine consistently reduced/abolished the phantom sensation in 6 out of 8 patients. These effects on phantom sensation were not observed after saline injections. Contralateral injections of 1 ml 0.25% bupivacaine in myofascial hyperalgesic areas attenuated phantom limb pain and affected phantom limb sensation. The clinical importance of this treatment method requires further investigation.

  4. Gadobenate dimeglumine (MultiHance) in MR angiography: an in-vitro phantom comparison with gadopentetate dimeglumine (Magnevist) at different concentrations.

    Science.gov (United States)

    Johansson, Lars; Kirchin, Miles A; Ahlström, Håkan

    2012-12-01

    Numerous clinical studies suggest that gadobenate dimeglumine is diagnostically superior to other gadolinium chelates for MR imaging applications, including contrast-enhanced MR angiography (CE-MRA). However, confirmatory in-vitro phantom studies have thus far been lacking. To evaluate the difference in signal intensity achieved with the high-relaxivity MR contrast agent gadobenate dimeglumine (MultiHance) relative to that achieved with the standard-relaxivity non-specific agent gadopentetate dimeglumine (Magnevist) at different concentrations using an in-vitro phantom study design. Test tubes with whole human blood were prepared with concentrations of gadobenate dimeglumine or gadopentetate dimeglumine ranging from 0 to 12 mM. A three-dimensional (3D) T1-weighted gradient echo sequence normally used for CE-MRA of the renal arteries was performed at flip angles of 25° and 35°. The signal-to-noise ratio (SNR) was calculated for all concentrations of both contrast agents. Furthermore a Look-Locker sequence was used and quantitative T1 mapping was performed for all the test tubes. The contrast agent concentration in the aorta was simulated using previously published data on T1 in the aorta during the first pass of a contrast agent. The differences between gadobenate dimeglumine and gadopentetate dimeglumine were compared at the simulated concentrations. The SNR achieved with gadobenate dimeglumine was consistently greater than that achieved with gadopentetate dimeglumine at all concentrations. An improvement of 15-25% in SNR was obtained when increasing the flip angle from 25° to 35°. The relative improvement in SNR with gadobenate dimeglumine relative to gadopentetate dimeglumine ranged from 25-72% and was markedly greater at lower concentrations with a flip angle of 35°. Our findings suggest that the relative benefit of gadobenate dimeglumine over gadopentetate dimeglumine for CE-MRA applications is greater at lower concentrations.

  5. FLUKA simulation studies on in-phantom dosimetric parameters of a LINAC-based BNCT

    Science.gov (United States)

    Ghal-Eh, N.; Goudarzi, H.; Rahmani, F.

    2017-12-01

    The Monte Carlo simulation code, FLUKA version 2011.2c.5, has been used to estimate the in-phantom dosimetric parameters for use in BNCT studies. The in-phantom parameters of a typical Snyder head, which are necessary information prior to any clinical treatment, have been calculated with both FLUKA and MCNPX codes, which exhibit a promising agreement. The results confirm that FLUKA can be regarded as a good alternative for the MCNPX in BNCT dosimetry simulations.

  6. Dosimetric study on head CT scans using adult and newborn phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Paiva de O, G. A.; Prata M, A., E-mail: giovanni_paiva@hotmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography is the radiodiagnostic method that most contributes to the dose deposition in population. Therefore, the dose reductions used in these tests are very important, especially for pediatric patients who have a life expectancy greater than the rest of the population. This study purpose to compare the doses generated from newborns compared to adult patients in head computed tomography scans. Two head phantoms in a cylindrical shape made in PMMA were used, one to adult and another to newborn patient dimensions. The pediatric routine scan protocol from a radiological service was used for the computed tomography scans. They were performed in General Electric Computed Tomography scanner, Bright Speed model with 4 channels. The absorbed dose measurements were performed with a pencil chamber placed into both phantoms. The newborn head phantom was developed in order to compare the amount of absorbed dose by the phantoms when it is used the same acquisition protocol. The dose found for newborn phantom was 29.9% higher than the adult phantom. (Author)

  7. Comparison study of reconstruction algorithms for prototype digital breast tomosynthesis using various breast phantoms.

    Science.gov (United States)

    Kim, Ye-seul; Park, Hye-suk; Lee, Haeng-Hwa; Choi, Young-Wook; Choi, Jae-Gu; Kim, Hak Hee; Kim, Hee-Joung

    2016-02-01

    Digital breast tomosynthesis (DBT) is a recently developed system for three-dimensional imaging that offers the potential to reduce the false positives of mammography by preventing tissue overlap. Many qualitative evaluations of digital breast tomosynthesis were previously performed by using a phantom with an unrealistic model and with heterogeneous background and noise, which is not representative of real breasts. The purpose of the present work was to compare reconstruction algorithms for DBT by using various breast phantoms; validation was also performed by using patient images. DBT was performed by using a prototype unit that was optimized for very low exposures and rapid readout. Three algorithms were compared: a back-projection (BP) algorithm, a filtered BP (FBP) algorithm, and an iterative expectation maximization (EM) algorithm. To compare the algorithms, three types of breast phantoms (homogeneous background phantom, heterogeneous background phantom, and anthropomorphic breast phantom) were evaluated, and clinical images were also reconstructed by using the different reconstruction algorithms. The in-plane image quality was evaluated based on the line profile and the contrast-to-noise ratio (CNR), and out-of-plane artifacts were evaluated by means of the artifact spread function (ASF). Parenchymal texture features of contrast and homogeneity were computed based on reconstructed images of an anthropomorphic breast phantom. The clinical images were studied to validate the effect of reconstruction algorithms. The results showed that the CNRs of masses reconstructed by using the EM algorithm were slightly higher than those obtained by using the BP algorithm, whereas the FBP algorithm yielded much lower CNR due to its high fluctuations of background noise. The FBP algorithm provides the best conspicuity for larger calcifications by enhancing their contrast and sharpness more than the other algorithms; however, in the case of small-size and low

  8. Evaluation of the image quality of chest CT scans: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Martins N, P. I.; Prata M, A., E-mail: priscillainglid@gmail.com [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) is considered one of the most important methods of medical imaging employed nowadays, due to its non-invasiveness and the high quality of the images it is able to generate. However, the diagnostic radiation dose received by an individual over the year often exceeds the dose received on account of background radiation. Therefore, it is important to know and to control the dose distribution in the patient by varying the image acquisition parameters. The aim of this study is to evaluate the variation of the image quality of chest CT scans performed by two phantoms. In this paper, a cylindrical Polymethyl Methacrylate (PMMA) chest phantom was used and a second PMMA phantom has been developed with the same volume but an oblong shape, based on the actual dimensions of a male human thorax, in the axillary region. Ten-centimeter scans of the central area of each phantom were performed by a 16-channel Toshiba CT scanner, model Alexion. The scanning protocol employed was the radiology service protocol for chest scans. The noise survey was conducted within the image of the center slice, in five regions: one central and four peripheral areas close to the edge of the object (anterior, posterior, left and right). The recorded values showed that the oblong phantom, with a shape that is more similar to the actual human chest, has a considerably smaller noise, especially in the anterior, posterior and central regions. (Author)

  9. In vitro dual perfusion of human placental lobules as a flow phantom to investigate the relationship between fetoplacental flow and quantitative 3D power doppler angiography.

    Science.gov (United States)

    Jones, N W; Hutchinson, E S; Brownbill, P; Crocker, I P; Eccles, D; Bugg, G J; Raine-Fenning, N J

    2009-02-01

    Flow phantoms have been used to investigate and quantify three-dimensional power Doppler data but this is the first study to use the in vitro, dual perfused, placental perfusion model. We used this model to investigate and quantify the effect of variation in fetal-side flow rates and attenuation on 3D power Doppler angiography. Perfusion of a placental lobule was commenced within 30 min of delivery and experimentation was successful in 8 of the 18 placenta obtained. Fetal and maternal perfusate was modified Earle's bicarbonate buffer which, following equilibration, was supplemented on the fetal side with whole heparinised cord blood. Imaging was performed with a Voluson-i ultrasound machine. A 'vascular biopsy' the thickness of the placental lobule was defined and signal quantified within using VOCAL (GE Medical Systems, Zipf, Austria). Three vascular indices are generated: vascularisation index (VI) defined as the percentage of power Doppler data within a volume of interest; flow index (FI), the mean signal intensity of the power Doppler information; and vascularisation flow index (VFI), a combination of both factors derived through their multiplication. Attenuation was investigated in this model with the addition of tissue mimic blocks. Our results showed a predictable relationship between flow rates and the vascular indices VI and VFI. However the FI was a less reliable predictor of flow; thus it should be interpreted with caution. The power Doppler signal was markedly affected by attenuation leading to a complete loss of information at a depth of 6 cm in the model used. In conclusion this model can be adapted to provide a phantom to analyse and quantify 3D power Doppler signals and demonstrates that vascular indices within a tissue remain related to volume flow. This model provides further evidence that depth dependent attenuation of signal needs to be accounted for in any in vivo work where the probe is not in direct contact with the tissue of interest.

  10. Evaluation of relaxation time measurements by magnetic resonance imaging. A phantom study

    DEFF Research Database (Denmark)

    Kjaer, L; Thomsen, C; Henriksen, O

    1987-01-01

    Several circumstances may explain the great variation in reported proton T1 and T2 relaxation times usually seen. This study was designed to evaluate the accuracy of relaxation time measurements by magnetic resonance imaging (MRI) operating at 1.5 tesla. Using a phantom of nine boxes with different...... concentrations of CuSO4 and correlating the calculated T1 and T2 values with reference values obtained by two spectrometers (corrected to MRI-proton frequency = 64 MHz) we found a maximum deviation of about 10 per cent. Measurements performed on a large water phantom in order to evaluate the homogeneity...

  11. Amputation, phantom pain and subjective well-being : a qualitative study

    NARCIS (Netherlands)

    Bosmans, J.C.; Suurmeijer, T.P.B.M.; Hulsink, M.; van der Schans, C.P.; Geertzen, J.H.B.; Dijkstra, P.U.

    The purpose of this qualitative study was to explore the impact of an amputation and of phantom pain on the subjective well-being of amputees. Sixteen lower-limb amputees were interviewed. A semi-structured interview and two Visual Analogue Scales were used. To interpret the results, a new

  12. Biopsy guided by real-time sonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C.; Grossjohann, Hanne Sønder; Nielsen, Kristina Rue

    2008-01-01

    OBJECTIVE: The purpose of our study was to test the accuracy of sonographically guided biopsies in a phantom of structures not visible on sonography but shown on MRI by using commercially available sonography systems with image fusion software. MATERIALS AND METHODS: A previously recorded MRI exa...

  13. Evaluation of relaxation time measurements by magnetic resonance imaging. A phantom study

    DEFF Research Database (Denmark)

    Kjaer, L; Thomsen, C; Henriksen, O

    1987-01-01

    Several circumstances may explain the great variation in reported proton T1 and T2 relaxation times usually seen. This study was designed to evaluate the accuracy of relaxation time measurements by magnetic resonance imaging (MRI) operating at 1.5 tesla. Using a phantom of nine boxes with different...

  14. Study on Compression Induced Contrast in X-ray Mammograms Using Breast Mimicking Phantoms

    Directory of Open Access Journals (Sweden)

    A. B. M. Aowlad Hossain

    2015-09-01

    Full Text Available X-ray mammography is commonly used to scan cancer or tumors in breast using low dose x-rays. But mammograms suffer from low contrast problem. The breast is compressed in mammography to reduce x-ray scattering effects. As tumors are stiffer than normal tissues, they undergo smaller deformation under compression. Therefore, image intensity at tumor region may change less than the background tissues. In this study, we try to find out compression induced contrast from multiple mammographic images of tumorous breast phantoms taken with different compressions. This is an extended work of our previous simulation study with experiment and more analysis. We have used FEM models for synthetic phantom and constructed a phantom using agar and n-propanol for simulation and experiment. The x-ray images of deformed phantoms have been obtained under three compression steps and a non-rigid registration technique has been applied to register these images. It is noticeably observed that the image intensity changes at tumor are less than those at surrounding which induce a detectable contrast. Addition of this compression induced contrast to the simulated and experimental images has improved their original contrast by a factor of about 1.4

  15. Development of newborn chest phantom for dosimetric study in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Aburjaile, W.N.; Lima, L.T.A.; Mourao, A.P., E-mail: wadia.namen@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Centro de Engenharia Biomédica

    2017-11-01

    Computed Tomography (CT) is a radiodiagnostic technique that allows evaluating the patient internal structures. In the last ten years, this technique has shown a high growth due to clinical cases of medical emergencies, neoplasm and pediatric traumas. The use dissemination of this technique has a significant increase in the patient dose. CT equipment installed in radiodiagnostic services present technological variations in the speed of acquisition or in the protocols used to obtain sectional images. The dose deposited in pediatric patients is directly related to energy retained during the exposure process to ionizing radiation, and radiation future effects is related with stochastic risks due to tissue radiosensitivity allied to the life expectancy of the child. The risk associated with a radiological examination can be considered quite low compared to the natural risk. However, any additional risk, no matter how small, is unacceptable if it does not benefit the patient. The knowledge of dose distribution is important when considering the variation of the acquisition parameters in order to reduce the dose. The objective of this work is to develop a newborn chest phantom for realize a comparative dosimetric study with the an adult standard phantom in order to evaluate the dose variation in CT scans. In this work, a cylindrical phantom, representing an adult chest made of polymethylmethacrylate (PMMA), was used and a new born chest phantom with a shape oblong was developed based on the dimensions of a typical newborn. In a GE CT scanner, Discovery model, with 64 channels, the central slice of the phantoms were irradiated successively in order to obtain dose measurements using an ionizing pencil camera. The radiological service chest protocol using a voltage of 120 kV was used for scanning 10 cm of the central area of the adult and newborn phantoms, in helical mode. The measurements have allowed to obtain the volumetric dose index values for the adult and newborn

  16. Impact of patient weight on tumor visibility based on human-shaped phantom simulation study in PET imaging system

    Science.gov (United States)

    Musarudin, M.; Saripan, M. I.; Mashohor, S.; Saad, W. H. M.; Nordin, A. J.; Hashim, S.

    2015-10-01

    Energy window technique has been implemented in all positron emission tomography (PET) imaging protocol, with the aim to remove the unwanted low energy photons. Current practices in our institution however are performed by using default energy threshold level regardless of the weight of the patient. Phantom size, which represents the size of the patient's body, is the factor that determined the level of scatter fraction during PET imaging. Thus, the motivation of this study is to determine the optimum energy threshold level for different sizes of human-shaped phantom, to represent underweight, normal, overweight and obese patients. In this study, the scanner was modeled by using Monte Carlo code, version MCNP5. Five different sizes of elliptical-cylinder shaped of human-sized phantoms with diameter ranged from 15 to 30 cm were modeled. The tumor was modeled by a cylindrical line source filled with 1.02 MeV positron emitters at the center of the phantom. Various energy window widths, in the ranged of 10-50% were implemented to the data. In conclusion, the phantom mass volume did influence the scatter fraction within the volume. Bigger phantom caused more scattering events and thus led to coincidence counts lost. We evaluated the impact of phantom sizes on the sensitivity and visibility of the simulated models. Implementation of wider energy window improved the sensitivity of the system and retained the coincidence photons lost. Visibility of the tumor improved as an appropriate energy window implemented for the different sizes of phantom.

  17. Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Mancosu, Pietro; Fogliata, Antonella, E-mail: Antonella.Fogliata@humanitas.it; Stravato, Antonella; Tomatis, Stefano; Cozzi, Luca; Scorsetti, Marta

    2016-07-01

    Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient's face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms' position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3 cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3 mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3 mm for displacement up to 1 cm and 1°, and 0.5 mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4 mm. Coverage of 1 camera produced an uncertainty < 0.5 mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.

  18. Anthropometric approaches and their uncertainties to assigning computational phantoms to individual patients in pediatric dosimetry studies

    Energy Technology Data Exchange (ETDEWEB)

    Whalen, Scott [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Lee, Choonsik [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Williams, Jonathan L [Department of Radiology, University of Florida, Gainesville, FL 32611 (United States); Bolch, Wesley E [Departments of Nuclear and Radiological and Biomedical Engineering, University of Florida, Gainesville, FL 32611 (United States)

    2008-01-21

    Current efforts to reconstruct organ doses in children undergoing diagnostic imaging or therapeutic interventions using ionizing radiation typically rely upon the use of reference anthropomorphic computational phantoms coupled to Monte Carlo radiation transport codes. These phantoms are generally matched to individual patients based upon nearest age or sometimes total body mass. In this study, we explore alternative methods of phantom-to-patient matching with the goal of identifying those methods which yield the lowest residual errors in internal organ volumes. Various thoracic and abdominal organs were segmented and organ volumes obtained from chest-abdominal-pelvic (CAP) computed tomography (CT) image sets from 38 pediatric patients ranging in age from 2 months to 15 years. The organs segmented included the skeleton, heart, kidneys, liver, lungs and spleen. For each organ, least-squared regression lines, 95th percentile confidence intervals and 95th percentile prediction intervals were established as a function of patient age, trunk volume, estimated trunk mass, trunk height, and three estimates of the ventral body cavity volume based on trunk height alone, or in combination with circumferential, width and/or breadth measurements in the mid-chest of the patient. When matching phantom to patient based upon age, residual uncertainties in organ volumes ranged from 53% (lungs) to 33% (kidneys), and when trunk mass was used (surrogate for total body mass as we did not have images of patient head, arms or legs), these uncertainties ranged from 56% (spleen) to 32% (liver). When trunk height is used as the matching parameter, residual uncertainties in organ volumes were reduced to between 21 and 29% for all organs except the spleen (40%). In the case of the lungs and skeleton, the two-fold reduction in organ volume uncertainties was seen in moving from patient age to trunk height-a parameter easily measured in the clinic. When ventral body cavity volumes were used

  19. Anthropometric approaches and their uncertainties to assigning computational phantoms to individual patients in pediatric dosimetry studies

    Science.gov (United States)

    Whalen, Scott; Lee, Choonsik; Williams, Jonathan L.; Bolch, Wesley E.

    2008-01-01

    Current efforts to reconstruct organ doses in children undergoing diagnostic imaging or therapeutic interventions using ionizing radiation typically rely upon the use of reference anthropomorphic computational phantoms coupled to Monte Carlo radiation transport codes. These phantoms are generally matched to individual patients based upon nearest age or sometimes total body mass. In this study, we explore alternative methods of phantom-to-patient matching with the goal of identifying those methods which yield the lowest residual errors in internal organ volumes. Various thoracic and abdominal organs were segmented and organ volumes obtained from chest-abdominal-pelvic (CAP) computed tomography (CT) image sets from 38 pediatric patients ranging in age from 2 months to 15 years. The organs segmented included the skeleton, heart, kidneys, liver, lungs and spleen. For each organ, least-squared regression lines, 95th percentile confidence intervals and 95th percentile prediction intervals were established as a function of patient age, trunk volume, estimated trunk mass, trunk height, and three estimates of the ventral body cavity volume based on trunk height alone, or in combination with circumferential, width and/or breadth measurements in the mid-chest of the patient. When matching phantom to patient based upon age, residual uncertainties in organ volumes ranged from 53% (lungs) to 33% (kidneys), and when trunk mass was used (surrogate for total body mass as we did not have images of patient head, arms or legs), these uncertainties ranged from 56% (spleen) to 32% (liver). When trunk height is used as the matching parameter, residual uncertainties in organ volumes were reduced to between 21 and 29% for all organs except the spleen (40%). In the case of the lungs and skeleton, the two-fold reduction in organ volume uncertainties was seen in moving from patient age to trunk height—a parameter easily measured in the clinic. When ventral body cavity volumes were used

  20. Prevalence of phantom limb pain, stump pain, and phantom limb sensation among the amputated cancer patients in India: A prospective, observational study

    Directory of Open Access Journals (Sweden)

    Arif Ahmed

    2017-01-01

    Full Text Available Introduction: The phantom limb pain (PLP and phantom limb sensation (PLS are very common among amputated cancer patients, and they lead to considerable morbidity. In spite of this, there is a lack of epidemiological data of this phenomenon among the Asian population. This study was done to provide the data from Indian population. Methods: The prevalence of PLP, stump pain (SP, and PLS was prospectively analyzed from the amputated cancer patients over a period of 2 years in Dr. B.R.A. Institute Rotary Cancer Hospital, All India Institute of Medical Sciences, New Delhi. The risk factors and the impact of phantom phenomenon on patients were also noted. Results: The prevalence of PLP was 41% at 3 and 12 months and 45.3% at 6 months, whereas that of SP and PLS was 14.4% and 71.2% at 3 months, 18.75% and 37.1% at 6 months, 15.8% and 32.4% at 12 months, respectively. There was higher prevalence of PLP and PLS among the patients with history of preamputation pain, smoking with proximal level of amputation, receiving general anesthesia, receiving intravenous (IV opioid postoperative analgesia, and developing neuroma or infection. Conclusion: The prevalence of PLP and PLS was higher among the cancer amputees as compared to SP, and a few risk factors responsible for their higher prevalence were found in our study. The PLP and PLS lead to considerable morbidity in terms of sleep disturbance and depression.

  1. Prevalence of Phantom Limb Pain, Stump Pain, and Phantom Limb Sensation among the Amputated Cancer Patients in India: A Prospective, Observational Study.

    Science.gov (United States)

    Ahmed, Arif; Bhatnagar, Sushma; Mishra, Seema; Khurana, Deepa; Joshi, Saurabh; Ahmad, Syed Mehmood

    2017-01-01

    The phantom limb pain (PLP) and phantom limb sensation (PLS) are very common among amputated cancer patients, and they lead to considerable morbidity. In spite of this, there is a lack of epidemiological data of this phenomenon among the Asian population. This study was done to provide the data from Indian population. The prevalence of PLP, stump pain (SP), and PLS was prospectively analyzed from the amputated cancer patients over a period of 2 years in Dr. B.R.A. Institute Rotary Cancer Hospital, All India Institute of Medical Sciences, New Delhi. The risk factors and the impact of phantom phenomenon on patients were also noted. The prevalence of PLP was 41% at 3 and 12 months and 45.3% at 6 months, whereas that of SP and PLS was 14.4% and 71.2% at 3 months, 18.75% and 37.1% at 6 months, 15.8% and 32.4% at 12 months, respectively. There was higher prevalence of PLP and PLS among the patients with history of preamputation pain, smoking with proximal level of amputation, receiving general anesthesia, receiving intravenous (IV) opioid postoperative analgesia, and developing neuroma or infection. The prevalence of PLP and PLS was higher among the cancer amputees as compared to SP, and a few risk factors responsible for their higher prevalence were found in our study. The PLP and PLS lead to considerable morbidity in terms of sleep disturbance and depression.

  2. Pixelized measurement of {sup 99m}Tc-HDP micro particles formed in gamma correction phantom pinhole scan: A reference study

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joo Young; Yoon, Do Kyun; Chung, Yong An [Catholic University of Korea, College of Medicine, Seoul (Korea, Republic of); Cheon, Gi Jeong; Lee, Yun Sang; Ha, Seunggyun [Radiopharmaceutical Science Laboratory, Dept. of Nuclear MedicineSeoul National University, College of Medicine, Seoul (Korea, Republic of); Bahk, Yong Whee [Dept. of Nuclear Medicine, Sung Ae General Hospital, Seoul (Korea, Republic of)

    2016-09-15

    Currently, traumatic bone diseases are diagnosed by assessing the micro {sup 99m}Tc-hydroxymethylene diphosphonate (HDP) uptake in injured trabeculae with ongoing osteoneogenesis demonstrated by gamma correction pinhole scan (GCPS). However, the mathematic size quantification of micro-uptake is not yet available. We designed and performed this phantom-based study to set up an in-vitro model of the mathematical calculation of micro-uptake by the pixelized measurement. The micro {sup 99m}Tc-HDP deposits used in this study were spontaneously formed both in a large standard flood and small house-made dish phantoms. The processing was as follows: first, phantoms were flooded with distilled water and {sup 99m}Tc-HDP was therein injected to induce micro {sup 99m}Tc-HDP deposition; second, the deposits were scanned using parallel-hole and pinhole collimator to generally survey {sup 99m}Tc-HDP deposition pattern; and third, the scans underwent gamma correction (GC) to discern individual deposits for size measurement. In original naïve scans, tracer distribution was simply nebulous in appearance and, hence, could not be measured. Impressively, however, GCPS could discern individual micro deposits so that they were calculated by pixelized measurement. Phantoms naturally formed micro {sup 99m}Tc-HDP deposits that are analogous to {sup 99m}Tc-HDP uptake on in-vivo bone scan. The smallest one we measured was 0.414 mm. Flooded phantoms and therein injected {sup 99m}Tc-HDP form nebulous micro {sup 99m}Tc-HDP deposits that are rendered discernible by GCPB and precisely calculable using pixelized measurement. This method can be used for precise quantitative and qualitative diagnosis of bone and joint diseases at the trabecular level.

  3. Cartesian positioning system for localization of blast and ballistic fragments: a phantom-based pilot study.

    Science.gov (United States)

    Folio, Les; Fischer, Tatjana; Shogan, Paul J; Frew, Michael; Bunger, Rolf; Provenzale, James M

    2011-11-01

    Our purpose was to demonstrate the consistency of radiologists' three-dimensional measurements of simulated blast fragment locations in vitro in an effort to objectively localize retained fragments and wound paths. We designed a phantom consisting of 10 nail heads (simulating blast fragments) glued to wooden pegs that were randomly situated at distances from a reference point within a plastic tub. The x, y, and z coordinates of simulated fragments were recorded in Cartesian 3-space relative to the reference point. Computed tomography images of the phantom were acquired. Differences in x, y, and z positions as determined by three observers were summed for each fragment. Agreement between recordings of coordinates across readers was assessed using the intraclass correlation coefficient. Summed differences in coordinate positions as determined by readers ranged between 0.00 and 1.204 cm (mean: 0.732 cm). Across readers, the intraclass correlation coefficient for each dimension was >0.99. We found excellent agreement among readers with minimal discrepancy of measured locations of simulated fragments. Our results provide a foundation for trajectory analysis necessary to lead to automated organ damage reporting for immediate assessment in the emergency department and for forensic investigation and long-term epidemiological analysis.

  4. Volumetric photoacoustic endoscopy of internal organs: a phantom and in situ study

    Science.gov (United States)

    Yang, Joon-Mo; Maslov, Konstantin; Chen, Ruimin; Yang, Hao-Chung; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2010-02-01

    In this study, we further developed our photoacoustic endoscopic system to produce three-dimensional images of internal organs by performing pullback C-scans. Employing the side-scanning photoacoustic endoscopic probe discussed in the Optical Society of America's journal Optics Letters, we could acquire successive B-scan images by pulling back the probe with a motorized linear stage. We demonstrate the endoscopic system's volumetric imaging ability through imaging of a metal wire phantom and an in situ rat rectum.

  5. Electrical Impedance Spectroscopic Studies on Broiler Chicken Tissue Suitable for the Development of Practical Phantoms in Multifrequency EIT

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2011-06-01

    Full Text Available Phantoms are essential for assessing the system performance in Electrical Impedance Tomography (EIT. Saline phantoms with insulator inhomogeneity fail to mimic the physiological structure of real body tissue in several aspects. Saline or any other salt solutions are purely resistive and hence studying multifrequency EIT systems cannot be assessed with saline phantoms because the response of the purely resistive materials do not change over frequency. Animal tissues show a variable response over a wide band of signal frequency due to their complex physiological and physiochemical structures and hence they can suitably be used as bathing medium and inhomogeneity in the phantoms of multifrequency EIT system. An efficient assessment of a multifrequency EIT system with real tissue phantom needs a prior knowledge of the impedance profile of the bathing medium as well as the inhomogeneity. In this direction Electrical Impedance Spectroscopy (EIS of broiler chicken muscle tissue paste and broiler chicken fat tissue is conducted from 10 Hz to 2 MHz using an impedance analyzer and their impedance profiles are thoroughly studied. Results show that the broiler chicken muscle tissue paste is less resistive than the fat tissue and hence it can be successfully used as the bathing medium of the phantoms for resistivity imaging in multifrequency EIT. Fat tissue is found more resistive than the muscle tissue which makes it more suitable for the inhomogeneity in phantoms of resistivity imaging study. doi:10.5617/jeb.174 J Electr Bioimp, vol. 2, pp. 48-63, 2011

  6. Optimization of yttrium-90 PET for simultaneous PET/MR imaging: A phantom study.

    Science.gov (United States)

    Eldib, Mootaz; Oesingmann, Niels; Faul, David D; Kostakoglu, Lale; Knešaurek, Karin; Fayad, Zahi A

    2016-08-01

    Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study. The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background. Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach. Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder. MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.

  7. Impact of magnetic field strength and receiver coil in ocular MRI: a phantom and patient study.

    Science.gov (United States)

    Erb-Eigner, K; Warmuth, C; Taupitz, M; Willerding, G; Bertelmann, E; Asbach, P

    2013-09-01

    Generally, high-resolution MRI of the eye is performed with small loop surface coils. The purpose of this phantom and patient study was to investigate the influence of magnetic field strength and receiver coils on image quality in ocular MRI. The eyeball and the complex geometry of the facial bone were simulated by a skull phantom with swine eyes. MR images were acquired with two small loop surface coils with diameters of 4 cm and 7 cm and with a multi-channel head coil at 1.5 and 3 Tesla, respectively. Furthermore, MRI of the eye was performed prospectively in 20 patients at 1.5 Tesla (7 cm loop surface coil) and 3 Tesla (head coil). These images were analysed qualitatively and quantitatively and statistical significance was tested using the Wilcoxon-signed-rank test (a p-value of less than 0.05 was considered to indicate statistical significance). The analysis of the phantom images yielded the highest mean signal-to-noise ratio (SNR) at 3 Tesla with the use of the 4 cm loop surface coil. In the phantom experiment as well as in the patient studies the SNR was higher at 1.5 Tesla by applying the 7 cm surface coil than at 3 Tesla by applying the head coil. Concerning the delineation of anatomic structures no statistically significant differences were found. Our results show that the influence of small loop surface coils on image quality (expressed in SNR) in ocular MRI is higher than the influence of the magnetic field strength. The similar visibility of detailed anatomy leads to the conclusion that the image quality of ocular MRI at 3 Tesla remains acceptable by applying the head coil as a receiver coil. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Evaluation of digital tomosynthesis reconstruction algorithms used to reduce metal artifacts for arthroplasty: A phantom study.

    Science.gov (United States)

    Gomi, Tsutomu; Sakai, Rina; Goto, Masami; Hara, Hidetake; Watanabe, Yusuke; Umeda, Tokuo

    2017-10-01

    To investigate methods to reduce metal artifacts during digital tomosynthesis for arthroplasty, we evaluated five algorithms with and without metal artifact reduction (MAR)-processing tested under different radiation doses (0.54, 0.47, and 0.33mSv): adaptive steepest descent projection onto convex sets (ASD-POCS), simultaneous algebraic reconstruction technique total variation (SART-TV), filtered back projection (FBP), maximum likelihood expectation maximization (MLEM), and SART. The algorithms were assessed by determining the artifact index (AI) and artifact spread function (ASF) on a prosthesis phantom. The AI data were statistically analyzed by two-way analysis of variance. Without MAR-processing, the greatest degree of effectiveness of the MLEM algorithm for reducing prosthetic phantom-related metal artifacts was achieved by quantification using the AI (MLEM vs. ASD-POCS, SART-TV, SART, and FBP; all PTV, and SART algorithms for reducing prosthetic phantom-related metal artifacts was achieved by quantification using the AI (MLEM, ASD-POCS, SART-TV, and SART vs. FBP; all PTV, and SART algorithm with MAR-processing. In ASF, the effect of metal artifact reduction was always greater at reduced radiation doses, regardless of which reconstruction algorithm with and without MAR-processing was used. In this phantom study, the MLEM algorithm without MAR-processing and ASD-POCS, SART-TV, and SART algorithm with MAR-processing gave improved metal artifact reduction. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Dosimetric study in chest computed tomography scans of adult and pediatric phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Namen A, W.; Prata M, A. [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Guedes, G., E-mail: wadia.namen@gmail.com [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    The computed tomography scan is a radiological technique that permits an evaluation of the patient internal structures. In the last ten years, this technique has had a high growth due to clinical cases of medical emergencies, cancer and pediatric trauma. Widespread of this technique has a significant increase in the patient dose. The risk associated with the radiological examination can be considered very low compared to the natural risk. However, any additional risk, no matter how small, is unacceptable if it does not benefit the patient. To be aware of the dose distribution is important when the objective is to vary the acquisition parameters aiming a dose reduction. The aim os this study is develop a pediatric chest phantom to evaluate the dose variation in CT scans. In this work, a cylindrical adult chest phantom made in polymethyl methacrylate was used and a second chest phantom was developed, based on dimensions of in eight year old patient in oblong shape. The two simulators have 5 openings, one is central and four are peripheral lagged by 90 degrees Celsius, which allow positioning a pencil chamber aiming and observation of the dose in 5 regions. In a GE CT scanner, Discovery model and 64 channels, the central slice of both simulators were irradiated successively to obtain dose measurements using a pencil chamber. The irradiation of the central slice was conducted using the service protocol. The registered dose values showed that the pediatric phantom had higher doses especially in the anterior, posterior and central regions. The results also enabled a comparison among the index dose values obtained from the measurements with the pencil chamber. (Author)

  10. Cross-sectional study of alteration of phantom limb pain with visceral stimulation in military personnel with amputation.

    Science.gov (United States)

    Rafferty, Michael; Bennett Britton, Thomas M; Drew, Benjamin T; Phillip, Rhodri D

    2015-01-01

    While phantom limb pain is a well-recognized phenomenon, clinical experience has suggested that the augmentation of phantom limb pain with visceral stimulation is an issue for many military personnel with amputation (visceral stimulation being the sensation of the bowel or bladder either filling or evacuating). However, the prevalence of this phenomenon is not known. The aim of this study was to investigate the prevalence of the alteration in phantom limb pain and the effect that visceral stimulation has on phantom limb pain intensity. A cross-sectional study of 75 military personnel who have lost one or both lower limbs completed a questionnaire to assess the prevalence of the alteration of phantom limb pain with visceral stimulation. Included in the questionnaire was a pain visual analog scale (VAS) graded from 0 to 10. Patients recorded the presence and intensity of phantom limb pain. They also recorded whether and how this pain altered with a need to micturate or micturition, and/or a need to defecate or defecation, again using a pain VAS. Time since amputation, level of amputation, and medications were also recorded. Patients reported a phantom limb pain prevalence of 85% with a mean VAS of 3.6. In all, 56% of patients reported a change in the severity of phantom limb pain with visceral stimuli. The mean increase in VAS for visceral stimulation was 2.5 +/- 1.6 for bladder stimulation and 2.9 +/- 2.0 for bowel stimulation. Of the patients questioned, 65% reported an improvement in symptoms over time. VAS scores were highest in the subgroup less than 6 mo postamputation. An increase in phantom limb pain with visceral stimulation is a common problem for military personnel with amputation.

  11. Dose reduction in multidetector CT of the urinary tract. Studies in a phantom model

    Energy Technology Data Exchange (ETDEWEB)

    Coppenrath, E.; Meindl, T.; Herzog, P.; Khalil, R.; Mueller-Lisse, U.; Krenn, L.; Reiser, M.; Mueller-Lisse, U.G. [Ludwig-Maximilians University of Munich, Clinical Radiology, Munich (Germany)

    2006-09-15

    A novel ureter phantom was developed for investigations of image quality and dose in CT urography. The ureter phantom consisted of a water box (14 cm x 32 cm x 42 cm) with five parallel plastic tubes (diameter 2.7 mm) filled with different concentrations of contrast media (1.88-30 mg iodine/ml). CT density of the tubes and noise of the surrounding water were determined using two multidetector scanners (Philips MX8000 with four rows, Siemens Sensation 16 with 16 rows) with varying tube current-time product (15-100 mAs per slice), voltage (90 kV, 100 kV, 120 kV), pitch (0.875-1.75), and slice thickness (1 mm, 2 mm, 3.2 mm). Contrast-to-noise ratio as a parameter of image quality was correlated with dose (CTDI) and was compared with image evaluation by two radiologists. The CT densities of different concentrations of contrast media and contrast-to-noise ratio were significantly higher when low voltages (90 kV versus 120 kV, 100 kV versus 120 kV) were applied. Smaller slice thickness (1 mm versus 2 mm) did not change CT density but decreased contrast-to-noise ratio due to increased noise. Contrast phantom studies showed favourable effects of low tube voltage on image quality in the low dose range. This may facilitate substantial dose reduction in CT urography. (orig.)

  12. Imaging of the thyroid and parathyroid using a cardiac cadmium zinc telluride camera: Phantom studies.

    Science.gov (United States)

    Miyazaki, Yosuke; Kato, Yasuhiro; Imoto, Akira; Fukuchi, Kazuki

    2017-11-10

    Purpose: Cadmium zinc telluride (CZT) detectors have recently been introduced to the field of clinical nuclear cardiology. However, the feasibility of using them for organs other than the heart remains unclear. The aim of this study was to evaluate the potential of a cardiac CZT camera to acquire thyroid and parathyroid images. We used custom-made phantoms and the currently available standard protocols for CZT, instead of a sodium-iodine scintillation (NaI) camera. Materials and Methods: Thyroid phantoms with or without parathyroid adenomas were made from agar using radiopharmaceuticals (99mTc or 123I) and imaged using CZT and NaI cameras. Using the CZT camera data, we prepared maximum intensity projection (MIP) images and planar equivalent (PE) images. Image counts were compared to those from the NaI camera, and the radioactivity of the phantoms was measured. For parathyroid imaging, three different protocols with the NaI camera were tested using MIP images. Results: For thyroid imaging, MIP could provide images as clear as those obtained from the NaI camera. The radioactivity and image counts correlated better for the PE images than the MIP images, especially for 123I images. We succeeded in obtaining clear parathyroid adenoma images from MIP images using all three protocols. Conclusion: A cardiac CZT camera can effectively perform qualitative and quantitative assessments of the thyroid and parathyroid organs. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko; Lampinen, Anniina [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); University of Helsinki, Department of Physics, Helsinki (Finland); Palmu, Kirsi [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); School of Science, Aalto University, Department of Biomedical Engineering and Computational Science, Helsinki (Finland); Reijonen, Vappu; Kortesniemi, Mika [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); Leikola, Junnu [University of Helsinki and Helsinki University Hospital, Department of Plastic Surgery, Helsinki (Finland); Kivisaari, Riku [University of Helsinki and Helsinki University Hospital, Department of Neurosurgery, Helsinki (Finland)

    2015-09-15

    Medical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis. To evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging. We scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues. Mean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level. Craniosynostosis CT with model-based iterative reconstruction could be performed with a 20-μSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality. (orig.)

  14. A quantitative evaluation of multiple biokinetic models using an assembled water phantom: A feasibility study.

    Directory of Open Access Journals (Sweden)

    Da-Ming Yeh

    Full Text Available This study examined the feasibility of quantitatively evaluating multiple biokinetic models and established the validity of the different compartment models using an assembled water phantom. Most commercialized phantoms are made to survey the imaging system since this is essential to increase the diagnostic accuracy for quality assurance. In contrast, few customized phantoms are specifically made to represent multi-compartment biokinetic models. This is because the complicated calculations as defined to solve the biokinetic models and the time-consuming verifications of the obtained solutions are impeded greatly the progress over the past decade. Nevertheless, in this work, five biokinetic models were separately defined by five groups of simultaneous differential equations to obtain the time-dependent radioactive concentration changes inside the water phantom. The water phantom was assembled by seven acrylic boxes in four different sizes, and the boxes were linked to varying combinations of hoses to signify the multiple biokinetic models from the biomedical perspective. The boxes that were connected by hoses were then regarded as a closed water loop with only one infusion and drain. 129.1±24.2 MBq of Tc-99m labeled methylene diphosphonate (MDP solution was thoroughly infused into the water boxes before gamma scanning; then the water was replaced with de-ionized water to simulate the biological removal rate among the boxes. The water was driven by an automatic infusion pump at 6.7 c.c./min, while the biological half-life of the four different-sized boxes (64, 144, 252, and 612 c.c. was 4.8, 10.7, 18.8, and 45.5 min, respectively. The five models of derived time-dependent concentrations for the boxes were estimated either by a self-developed program run in MATLAB or by scanning via a gamma camera facility. Either agreement or disagreement between the practical scanning and the theoretical prediction in five models was thoroughly discussed. The

  15. Preliminary study of the 270 Bloom Fricke xylenol gel phantom performance for 3D conformal radiotherapy using multiple radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Cavinato, Christianne C.; Campos, Leticia L., E-mail: ccavinato@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (DIRF/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Gerencia de Metrologia das Radiacoes; Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B. [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Dept. de Diagnostico por Imagens; Giordani, Adelmo J. [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Servico de Radioterapia

    2011-07-01

    The complex cancer treatment techniques require rigorous quality control (QC). The Fricke xylenol gel (FXG) dosimeter has been studied to be applied as a three-dimensional (3D) dosimeter since it is possible to produce 3D FXG phantoms of various shapes and sizes. In this preliminary study, the performance of the FXG spherical phantom developed at IPEN, prepared using 270 Bloom gelatin from porcine skin made in Brazil, was evaluated using magnetic resonance imaging technique, aiming to use this phantom to 3D conformal radiotherapy (3DCRT) with multiple radiation fields and clinical photon beams. The obtained results indicate that for all magnetic resonance images of the FXG phantom irradiated with 6 MV clinical photon beam can be observed clearly the target volume and, in the case of coronal image, can also be observed the radiation beam projection and the overlap of different radiation fields used. The Fricke xylenol gel phantom presented satisfactory results for 3DCRT and clinical photon beams in this preliminary study. These results encourage the additional tests using complex treatment techniques and indicate the viability of applying the phantom studied to routine quality control measurements and in 3DCRT and intensity modulated radiotherapy treatment planning. (author)

  16. Reducing motion artifacts in photoplethysmograms by using relative sensor motion: phantom study

    Science.gov (United States)

    Wijshoff, Ralph W. C. G. R.; Mischi, Massimo; Veen, Jeroen; van der Lee, Alexander M.; Aarts, Ronald M.

    2012-11-01

    Currently, photoplethysmograms (PPGs) are mostly used to determine a patient's blood oxygenation and pulse rate. However, PPG morphology conveys more information about the patient's cardiovascular status. Extracting this information requires measuring clean PPG waveforms that are free of artifacts. PPGs are highly susceptible to motion, which can distort the PPG-derived data. Part of the motion artifacts are considered to result from sensor-tissue motion and sensor deformation. It is hypothesized that these motion artifacts correlate with movement of the sensor with respect to the skin. This hypothesis has been proven true in a laboratory setup. In vitro PPGs have been measured in a skin perfusion phantom that is illuminated by a laser diode. Optical motion artifacts are generated in the PPG by translating the laser diode with respect to the PPG photodiode. The optical motion artifacts have been reduced significantly in vitro, by using a normalized least-mean-square algorithm with only a single coefficient that uses the laser's displacement as a reference for the motion artifacts. Laser displacement has been measured accurately via self-mixing interferometry by a compact laser diode with a ball lens integrated into the package, which can be easily integrated into a commercial sensor.

  17. The influence of patient size on dose conversion coefficients: a hybrid phantom study for adult cardiac catheterization

    Science.gov (United States)

    Johnson, Perry; Lee, Choonsik; Johnson, Kevin; Siragusa, Daniel; Bolch, Wesley E.

    2009-06-01

    In this study, the influence of patient size on organ and effective dose conversion coefficients (DCCs) was investigated for a representative interventional fluoroscopic procedure—cardiac catheterization. The study was performed using hybrid phantoms representing an underweight, average and overweight American adult male. Reference body sizes were determined using the NHANES III database and parameterized based on standing height and total body mass. Organ and effective dose conversion coefficients were calculated for anterior-posterior, posterior-anterior, left anterior oblique and right anterior oblique projections using the Monte Carlo code MCNPX 2.5.0 with the metric dose area product being used as the normalization factor. Results show body size to have a clear influence on DCCs which increased noticeably when body size decreased. It was also shown that if patient size is neglected when choosing a DCC, the organ and effective dose will be underestimated to an underweight patient and will be overestimated to an underweight patient, with errors as large as 113% for certain projections. Results were further compared with those published for a KTMAN-2 Korean patient-specific tomographic phantom. The published DCCs aligned best with the hybrid phantom which most closely matched in overall body size. These results highlighted the need for and the advantages of phantom-patient matching, and it is recommended that hybrid phantoms be used to create a more diverse library of patient-dependent anthropomorphic phantoms for medical dose reconstruction.

  18. Optimisation of pulsed and pseudo-continuous arterial spin labeling MRI techniques: A phantom study

    Science.gov (United States)

    Yusoff, Norain; Zukhi, Jihan; Rusli, Awatif; Zainon, Rafidah

    2017-05-01

    Arterial Spin Labeling (ASL) MRI is a non-invasive technique using a freely diffusible intrinsic tracer. The main objective of this study is to evaluate two different techniques of ASL MRI; pulsed ASL (PASL) and pseudo-continuous ASL (PCASL) in obtaining the best signal by manipulating the different imaging parameters. We used a fabricated Perspex flow phantom that is magnetically susceptible. The phantom has a straight tube that mimics carotid artery in adult patients and a U-shaped tube with 75% stenosis. We used a mixture of 60:40 distilled water and glycerol respectively as a substitute to blood. The fabricated phantom was scanned with 1.5T and 3T MRI Scanner using PCASL technique and PASL respectively. Two main imaging parameters were studied which were the field of view (FOV) and slice thickness (ST) to obtain the signal-to-noise ratio (SNR) of the region of interests. The 1.5 T PCASL technique gave SNR values of (13, 22, 30.1) for ST (5, 7, 9 mm) and FOV 240. When higher FOV = 320 was selected, the SNR values were (26.8, 15, 37) for different ST (5, 7, 9 mm). The 3.0 T PASL technique gave the SNR values of (9, 9.3, 11) for ST (5, 7, 9mm) and FOV 240mm. In the higher FOV = 320 mm, we obtained SNR values of (15.2, 17.5, 37.2) for ST (5, 7, 9 mm). As a conclusion, the images quality which can be measured by SNR value is affected by types of ASL and also different parameters.

  19. Comparison of longitudinal excursion of a nerve-phantom model using quantitative ultrasound imaging and motion analysis system methods: A convergent validity study.

    Science.gov (United States)

    Paquette, Philippe; El Khamlichi, Youssef; Lamontagne, Martin; Higgins, Johanne; Gagnon, Dany H

    2017-08-01

    Quantitative ultrasound imaging is gaining popularity in research and clinical settings to measure the neuromechanical properties of the peripheral nerves such as their capability to glide in response to body segment movement. Increasing evidence suggests that impaired median nerve longitudinal excursion is associated with carpal tunnel syndrome. To date, psychometric properties of longitudinal nerve excursion measurements using quantitative ultrasound imaging have not been extensively investigated. This study investigates the convergent validity of the longitudinal nerve excursion by comparing measures obtained using quantitative ultrasound imaging with those determined with a motion analysis system. A 38-cm long rigid nerve-phantom model was used to assess the longitudinal excursion in a laboratory environment. The nerve-phantom model, immersed in a 20-cm deep container filled with a gelatin-based solution, was moved 20 times using a linear forward and backward motion. Three light-emitting diodes were used to record nerve-phantom excursion with a motion analysis system, while a 5-cm linear transducer allowed simultaneous recording via ultrasound imaging. Both measurement techniques yielded excellent association ( r  = 0.99) and agreement (mean absolute difference between methods = 0.85 mm; mean relative difference between methods = 7.48 %). Small discrepancies were largely found when larger excursions (i.e. > 10 mm) were performed, revealing slight underestimation of the excursion by the ultrasound imaging analysis software. Quantitative ultrasound imaging is an accurate method to assess the longitudinal excursion of an in vitro nerve-phantom model and appears relevant for future research protocols investigating the neuromechanical properties of the peripheral nerves.

  20. Phantom Pain

    Science.gov (United States)

    ... 16, 2014. Phantom pain Symptoms & causes Diagnosis & treatment Advertisement Mayo Clinic does not endorse companies or products. ... a Job Site Map About This Site Twitter Facebook Google YouTube Pinterest Mayo Clinic is a not- ...

  1. New weighting factor of weighted CTDI equation for PMMA phantom diameter from 8 to 40 cm: A Monte Carlo study.

    Science.gov (United States)

    Haba, Tomonobu; Koyama, Shuji; Kinomura, Yutaka; Ida, Yoshihiro; Kobayashi, Masanao

    2017-12-01

    The weighted computed tomography dose index (CTDIw ) uses measured CTDI values at the center and periphery of a cylindrical phantom. The CTDIw value is calculated using conventional, Bakalyar's, and Choi's weighting factors. However, these weighting factors were produced from only 16- and 32-cm-diameter cylindrical phantoms. This study aims to devise new weighting factors to provide more accurate average dose in the central cross-sectional plane of cylindrical phantoms over a wide range of object diameters, by using Monte Carlo simulations. Simulations were performed by modeling a Toshiba Aquilion ONE CT scanner, in order to compute the cross-sectional dose profiles of polymethyl methacrylate (PMMA) cylindrical phantoms of each diameter (8-40 cm at 4-cm steps), for various tube voltages and longitudinal beam widths. Two phantom models were simulated, corresponding to the CTDI100 method and the method recommended by American Association of Physicists in Medicine (AAPM) task group 111. The dose-computation PMMA cylinders of 1 mm diameter were located between the phantom surfaces and the centers at intervals of 1 mm, from which cross-sectional dose profiles were calculated. By using linear least-squares fits to the obtained cross-sectional dose profiles data, we determined new weighting factors to estimate more accurate average doses in the PMMA cylindrical phantoms by using the CTDIw equation: CTDIw = Wcenter ・ CTDIcenter + Wperiphery ・ CTDIperiphery . In order to demonstrate the validity of the devised new weighting factors, the percentage difference between average dose and CTDIw value was evaluated for the weighting factors (conventional, Bakalyar's, Choi's, and devised new weighting factors) in each calculated cross-sectional dose profile. With the use of linear least-squares techniques, new weighting factors (Wcenter = 3/8 and Wperiphery = 5/8 where Wcenter and Wperiphery are weighting factors for CTDIcenter and CTDIperiphery ) were determined. The maximum

  2. Dosimetric study of thermoluminescent detectors in clinical photon beams using liquid water and PMMA phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Luciana C., E-mail: lmatsushima@ipen.br [Gerencia de Metrologia das Radiacoes (GMR) - Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, CEP: 05508-000, Sao Paulo, SP (Brazil); Veneziani, Glauco R. [Gerencia de Metrologia das Radiacoes (GMR) - Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, CEP: 05508-000, Sao Paulo, SP (Brazil); Sakuraba, Roberto K. [Gerencia de Metrologia das Radiacoes (GMR) - Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, CEP: 05508-000, Sao Paulo, SP (Brazil); Sociedade Beneficente Israelita Brasileira - Hospital Albert Einstein (HAE), Avenida Albert Einstein, 665, Morumbi, CEP: 05652-000, Sao Paulo, SP (Brazil); Cruz, Jose C. da [Sociedade Beneficente Israelita Brasileira - Hospital Albert Einstein (HAE), Avenida Albert Einstein, 665, Morumbi, CEP: 05652-000, Sao Paulo, SP (Brazil)

    2012-07-15

    The purpose of this study was the dosimetric evaluation of thermoluminescent detectors of calcium sulphate doped with dysprosium (CaSO{sub 4}:Dy) produced by IPEN compared to the TL response of lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti) dosimeters and microdosimeters produced by Harshaw Chemical Company to clinical photon beams dosimetry (6 and 15 MV) using liquid water and PMMA phantoms. - Highlights: Black-Right-Pointing-Pointer Dosimetric study of thermoluminescent detectors of CaSO{sub 4}:Dy, LiF:Mg,Ti and {mu}LiF:Mg,Ti. Black-Right-Pointing-Pointer Clinical (6 and 15 MV) photon beams dosimetry using liquid water and PMMA phantom. Black-Right-Pointing-Pointer Linear behavior to the dose range (0.1 to 5 Gy). Black-Right-Pointing-Pointer TL response reproducibility better than {+-}4.34%. Black-Right-Pointing-Pointer CaSO{sub 4}:Dy represent a cheaper alternative to the TLD-100.

  3. Operator radiation exposure during right or left transradial coronary angiography: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Sciahbasi, Alessandro, E-mail: alessandro.sciahbasi@fastwebnet.it [Interventional Cardiology, Sandro Pertini Hospital, Rome (Italy); Rigattieri, Stefano [Interventional Cardiology, Sandro Pertini Hospital, Rome (Italy); Sarandrea, Alessandro [HSE Management, Rome (Italy); Cera, Maria; Di Russo, Cristian; Fedele, Silvio [Interventional Cardiology, Sandro Pertini Hospital, Rome (Italy); Romano, Silvio [Cardiology, University of L’Aquila, Rome (Italy); Pugliese, Francesco Rocco [Emergency Department, Sandro Pertini Hospital, Rome (Italy); Penco, Maria [Cardiology, University of L’Aquila, Rome (Italy)

    2015-10-15

    Background: Previous studies showed a possible lower radiation dose absorbed by operators comparing LRA and RRA for percutaneous coronary procedures. The reasons of this lower radiation dose are not well known. The aim of this study was to evaluate the radiation dose absorbed by operators comparing left with right radial access (LRA and RRA respectively) during a simulated diagnostic coronary angiography using a phantom. Methods: A coronary angiography examination was simulated on a phantom by 5 operators using eight projections with 5 seconds fluoroscopy each. Each operator was equipped with 4 electronic dosimeters placed at thorax, at left wrist, at left head and at hip level. Radiation doses were expressed in picosievert and normalized by dose area product. Results: LRA compared to RRA was associated with a significant lower operator dose at wrist (36 pSv/cGYcm{sup 2} [IQR 18–59 pSv/cGYcm{sup 2}] and 48 pSv/cGYcm{sup 2} [IQR 22–148 pSv/cGYcm{sup 2}] respectively, p = 0.01) and thorax (3 pSv/cGYcm{sup 2} [IQR 2–5 pSv/cGYcm{sup 2}] and 10 pSv/cGYcm{sup 2} [6–23 pSv/cGYcm{sup 2}] respectively, p < 0.001) but with a significant higher radiation dose at hip level (102 pSv/cGYcm{sup 2} [IQR 44–199 pSv/cGYcm{sup 2}] and 67 pSv/cGYcm{sup 2} [IQR 39–132 pSv/cGYcm{sup 2}] respectively, p = 0.02). Conversely the radiation dose at left side of the head did not show significant differences between the two approaches. Conclusions: In this phantom study simulating a diagnostic coronarography the use of LRA compared to RRA was associated with a significant lower radiation dose at wrist and thorax but with an increased dose at hip level. Summary: To evaluate the radiation dose absorbed by operators comparing left with right radial access (LRA and RRA respectively) we simulated a diagnostic coronary angiography using a dedicated phantom. Operators were equipped with dedicated electronic dosimeters at wrist, hip, head and thorax level. LRA compared to RRA was

  4. Ocular MR imaging: evaluation of different coil setups in a phantom study.

    Science.gov (United States)

    Erb-Eigner, Katharina; Warmuth, Carsten; Taupitz, Matthias; Bertelmann, Eckart; Hamm, Bernd; Asbach, Patrick

    2013-01-01

    Small loop surface coils are generally recommended for ocular magnetic resonance (MR) imaging, but the optimal coil setup has not been systematically investigated. In this phantom study, we investigated which coil setup of those coils available for our MR imaging system provides the highest signal-to-noise ratio (SNR) in ocular MR imaging at 1.5 tesla. Using a phantom to simulate the eyeball and the orbital fat, we employed loop surface coils of 4- and 6-cm diameter and a multi-channel head coil to obtain images using a T1-weighted spin-echo sequence and then measured the SNR for each coil and coil combination. Use of the 6-cm loop coil alone yielded the highest mean SNR (27.5). Even in superficial regions (mesial and temporal), the SNR was higher using the 6-cm loop coil (33.6 and 45.5) than the 4-cm loop coil (28.0 and 33.8). Additional use of the head coil reduced the mean SNR to 10.4. This quantitative analysis suggests that use of a 6-cm loop surface coil offers the best results in ocular MR imaging. Combinations of loop coils or additional use of a head coil cannot be recommended because higher noise degrades image quality.

  5. Phantom and animal imaging studies using PLS synchrotron X-rays

    CERN Document Server

    Hee Joung Kim; Kyu Ho Lee; Hai Jo Jung; Eun Kyung Kim; Jung Ho Je; In Woo Kim; Yeukuang, Hwu; Wen Li Tsai; Je Kyung Seong; Seung Won Lee; Hyung Sik Yoo

    2001-01-01

    Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ultra-high resolution images for, resolution test patterns, mammograph...

  6. Iterative metal artifact reduction improves dose calculation accuracy. Phantom study with dental implants

    Energy Technology Data Exchange (ETDEWEB)

    Maerz, Manuel; Mittermair, Pia; Koelbl, Oliver; Dobler, Barbara [Regensburg University Medical Center, Department of Radiotherapy, Regensburg (Germany); Krauss, Andreas [Siemens Healthcare GmbH, Forchheim (Germany)

    2016-06-15

    Metallic dental implants cause severe streaking artifacts in computed tomography (CT) data, which affect the accuracy of dose calculations in radiation therapy. The aim of this study was to investigate the benefit of the metal artifact reduction algorithm iterative metal artifact reduction (iMAR) in terms of correct representation of Hounsfield units (HU) and dose calculation accuracy. Heterogeneous phantoms consisting of different types of tissue equivalent material surrounding metallic dental implants were designed. Artifact-containing CT data of the phantoms were corrected using iMAR. Corrected and uncorrected CT data were compared to synthetic CT data to evaluate accuracy of HU reproduction. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated in Oncentra v4.3 on corrected and uncorrected CT data and compared to Gafchromic trademark EBT3 films to assess accuracy of dose calculation. The use of iMAR increased the accuracy of HU reproduction. The average deviation of HU decreased from 1006 HU to 408 HU in areas including metal and from 283 HU to 33 HU in tissue areas excluding metal. Dose calculation accuracy could be significantly improved for all phantoms and plans: The mean passing rate for gamma evaluation with 3 % dose tolerance and 3 mm distance to agreement increased from 90.6 % to 96.2 % if artifacts were corrected by iMAR. The application of iMAR allows metal artifacts to be removed to a great extent which leads to a significant increase in dose calculation accuracy. (orig.) [German] Metallische Implantate verursachen streifenfoermige Artefakte in CT-Bildern, welche die Dosisberechnung beeinflussen. In dieser Studie soll der Nutzen des iterativen Metall-Artefakt-Reduktions-Algorithmus iMAR hinsichtlich der Wiedergabetreue von Hounsfield-Werten (HU) und der Genauigkeit von Dosisberechnungen untersucht werden. Es wurden heterogene Phantome aus verschiedenen Arten gewebeaequivalenten Materials mit

  7. Internal photon and electron dosimetry of the newborn patient—a hybrid computational phantom study

    Science.gov (United States)

    Wayson, Michael; Lee, Choonsik; Sgouros, George; Treves, S. Ted; Frey, Eric; Bolch, Wesley E.

    2012-03-01

    Estimates of radiation absorbed dose to organs of the nuclear medicine patient are a requirement for administered activity optimization and for stochastic risk assessment. Pediatric patients, and in particular the newborn child, represent that portion of the patient population where such optimization studies are most crucial owing to the enhanced tissue radiosensitivities and longer life expectancies of this patient subpopulation. In cases where whole-body CT imaging is not available, phantom-based calculations of radionuclide S values—absorbed dose to a target tissue per nuclear transformation in a source tissue—are required for dose and risk evaluation. In this study, a comprehensive model of electron and photon dosimetry of the reference newborn child is presented based on a high-resolution hybrid-voxel phantom from the University of Florida (UF) patient model series. Values of photon specific absorbed fraction (SAF) were assembled for both the reference male and female newborn using the radiation transport code MCNPX v2.6. Values of electron SAF were assembled in a unique and time-efficient manner whereby the collisional and radiative components of organ dose--for both self- and cross-dose terms—were computed separately. Dose to the newborn skeletal tissues were assessed via fluence-to-dose response functions reported for the first time in this study. Values of photon and electron SAFs were used to assemble a complete set of S values for some 16 radionuclides commonly associated with molecular imaging of the newborn. These values were then compared to those available in the OLINDA/EXM software. S value ratios for organ self-dose ranged from 0.46 to 1.42, while similar ratios for organ cross-dose varied from a low of 0.04 to a high of 3.49. These large discrepancies are due in large part to the simplistic organ modeling in the stylized newborn model used in the OLINDA/EXM software. A comprehensive model of internal dosimetry is presented in this study for

  8. Phantom behavioral assimilation effects: systematic biases in social comparison choice studies.

    Science.gov (United States)

    Marsh, Herbert W; Seaton, Marjorie; Kuyper, Hans; Dumas, Florence; Huguet, Pascal; Régner, Isabelle; Buunk, Abraham P; Monteil, Jean-Marc; Gibbons, Frederick X

    2010-04-01

    Consistent with social comparison theory (SCT), Blanton, Buunk, Gibbons, and Kuyper (1999) and Huguet, Dumas, Monteil, and Genestoux (2001) found that students tended to choose comparison targets who slightly outperformed them (i.e., upward comparison choices), and this had a beneficial effect on subsequent performance--a behavioral assimilation effect (BAE). We show (Studies 1 and 2) that this apparent BAE is due, in part, to uncontrolled measurement error in pretest achievement. However, using simulated data (Study 3), these phantom BAEs were eliminated with latent-variable models with multiple indicators. In Studies 4 and 5, latent-variable models were applied to the Blanton et al. and Huguet et al. data, resulting in substantially smaller but still significantly positive BAEs. More generally in personality research based on correlational data, failure to control measurement error in pretest/background variables will positively bias the apparent effects of personality variables of interest, but widely applicable approaches demonstrated here can correct for these biases.

  9. The impact of CBCT reconstruction and calibration for radiotherapy planning in the head and neck region - a phantom study.

    Science.gov (United States)

    Elstrøm, Ulrik V; Olsen, Sune R K; Muren, Ludvig P; Petersen, Jørgen B B; Grau, Cai

    2014-08-01

    The applicability of cone-beam computed tomography (CBCT) image sets for dose calculation purposes relies on high image quality and CT number accuracy. In this study we have investigated the use of stoichiometric calibration for transforming CT numbers into physical parameters, in combination with a new CBCT scatter correction algorithm, focusing on head and neck geometries. CBCT projections were acquired using an On-Board-Imager (OBI v1.4; Varian Medical Systems) using both low- and high-dose clinical image acquisition protocols. The CBCT projections were reconstructed twice, using both the standard method (OBI) as well as an experimental pre-clinical reconstruction algorithm (Full Fan Experimental - FFE). Stoichiometric calibration was performed using both a phantom from CIRS with nine tissue equivalent inserts (ranging from lung to dense bone) as well as with a custom made cylindrical PMMA head and neck phantom with variable 'head' diameter and with cavities designed to fit the inserts from a Gammex RMI phantom. To benchmark the CBCT performance, the same calibration procedures were performed using two conventional CT scanners. For assessment of influence on dose-volume parameters, the head part of the anthropomorphic Alderson phantom was scanned, reconstructed with both CT and CBCT using the stoichiometric calibration curves, and finally used to compare IMRT dose calculations. The stoichiometric CBCT calibrations with the CIRS phantom resulted in an excellent fit between calculated and measured CT numbers (R = 1.000 for all combinations tested), equivalent to the results for the conventional scanners. Using the PMMA phantom, the stoichiometric calibration curves again showed excellent agreement, although the OBI reconstruction showed marginally increasing deviation from the unity line as the phantom size decreased. For the dose-volume parameters, deviations well within 1% were seen between the different reconstruction methods and acquisition modes. This study

  10. Phantom thermodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Diaz, Pedro F. [Colina de los Chopos, Centro de Fisica ' Miguel A. Catalan' , Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid (Spain)]. E-mail: p.gonzalezdiaz@imaff.cfmac.csic.es; Sigueenza, Carmen L. [Colina de los Chopos, Centro de Fisica ' Miguel A. Catalan' , Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid (Spain)

    2004-10-04

    This paper deals with the thermodynamic properties of a phantom field in a flat Friedmann-Robertson-Walker universe. General expressions for the temperature and entropy of a general dark-energy field with equation of state p={omega}{rho} are derived from which we have deduced that, whereas the temperature of a cosmic phantom fluid ({omega}-1) is definite negative, its entropy is always positive. We interpret that result in terms of the intrinsic quantum nature of the phantom field and apply it to (i) attain a consistent explanation for some recent results concerning the evolution of black holes which,induced by accreting phantom energy, gradually loss their mass to finally vanish exactly at the big rip, and (ii) introduce the concept of cosmological information and its relation with life and the anthropic principle. Some quantum statistical-thermodynamic properties of the quantum field are also considered that include a generalized Wien law and the prediction of some novel phenomena such as the stimulated absorption of phantom energy and the anti-laser effect.

  11. Radiotracer dose reduction in integrated PET/MR: implications from national electrical manufacturers association phantom studies.

    Science.gov (United States)

    Oehmigen, Mark; Ziegler, Susanne; Jakoby, Bjoern W; Georgi, Jens-Christoph; Paulus, Daniel H; Quick, Harald H

    2014-08-01

    With the replacement of ionizing CT by MR imaging, integrated PET/MR in selected clinical applications may reduce the overall patient radiation dose when compared with PET/CT. Further potential for radiotracer dose reduction, while maintaining PET image quality (IQ) in integrated PET/MR, may be achieved by increasing the PET acquisition duration to match the longer time needed for MR data acquisition. To systematically verify this hypothesis under controlled conditions, this dose-reduction study was performed using a standardized phantom following the National Electrical Manufacturers Association (NEMA) IQ protocol. All measurements were performed on an integrated PET/MR whole-body hybrid system. The NEMA IQ phantom was filled with water and a total activity of 50.35 MBq of (18)F-FDG. The sphere-to-background activity ratio was 8:1. Multiple PET data blocks of 20-min acquisition time were acquired in list-mode format and were started periodically at multiples of the (18)F-FDG half-lives. Different sinograms (2, 4, 8, and 16 min in duration) were reconstructed. Attenuation correction of the filled NEMA phantom was performed using a CT-based attenuation map template. The attenuation-corrected PET images were then quantitatively evaluated following the NEMA IQ protocol, investigating contrast recovery, background variability, and signal-to-noise ratio. Image groups with half the activity and twice the acquisition time were evaluated. For better statistics, the experiment was repeated 3 times. Contrast recovery, background variability, and signal-to-noise ratio remained almost constant over 3 half-life periods when the decreasing radiotracer activity (100%, 50%, 25%, and 12.5%) was compensated by increasing acquisition time (2, 4, 8, and 16 min). The variation of contrast recovery over 3 half-life periods was small (-6% to +7%), with a mean variation of 2%, compared with the reference setting (100%, 2 min). The signal-to-noise ratio of the hot spheres showed only minor

  12. Accuracy of visual scoring and semi-quantification of ultrasound strain elastography--a phantom study.

    Directory of Open Access Journals (Sweden)

    Jonathan Frederik Carlsen

    Full Text Available PURPOSE: The aim of this study was to evaluate the performance of strain elastography in an elasticity phantom and to assess which factors influenced visual scoring, strain histograms and strain ratios. Furthermore this study aimed to evaluate the effect of observer experience on visual scorings. MATERIALS AND METHODS: Two operators examined 20 targets of various stiffness and size (16.7 to 2.5 mm in an elasticity phantom at a depth of 3.5 cm with a 5-18 MHz transducer. Two pre-settings were used yielding 80 scans. Eight evaluators, four experienced, four inexperienced, performed visual scorings. Cut-offs for semi-quantitative methods were established for prediction of target stiffness. Data was pooled in two categories allowing calculations of sensitivity and specificity. Statistical tests chi-square test and linear regression as relevant. RESULTS: Strain ratios and strain histograms were superior to visual scorings of both experienced and inexperienced observers (p = 0.025, strain histograms vs. experienced observers, p<0.001, strain histograms vs. inexperienced observers, p = 0.044 strain ratios vs. experienced observers and p = 0.002 strain ratios vs. inexperienced observers. No significant difference in predicting target stiffness between strain ratios and strain histograms (p = 0.83 nor between experienced and inexperienced observers (p = 0.054 was shown when using four categories. When pooling data in two groups (80 kPa/45 kPa vs. 14/8 kPa the difference between the observers became significant (p<0.001. Target size had a significant influence on strain ratios measurements (p = 0.017 and on visual scorings (p<0.001 but not on the strain histograms(p = 0.358. Observer experience had significant effect on visual scorings(p = 0.003. CONCLUSION: Strain ratios and strain histograms are superior to visual scoring in assessing target stiffness in a phantom. Target size had a significant impact on strain ratios and

  13. Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study

    Science.gov (United States)

    Figueira, C.; Becker, F.; Blunck, C.; DiMaria, S.; Baptista, M.; Esteves, B.; Paulo, G.; Santos, J.; Teles, P.; Vaz, P.

    2013-08-01

    This work aims to contribute to the study of the radiation dose distribution delivered to the hands of medical staff members during a general computed tomographic (CT) fluoroscopic guided procedure. In this study, both Monte Carlo simulations and measurements were performed. For free-in-air and computed tomography dose index (CTDI) body phantom measurements, a standard pencil ionization chamber (IC) 100 mm long was used. The CT scanner model was implemented using MCNPX (Monte Carlo N-Particle eXtended) and was successfully validated by comparing the simulated results with measurements. Subsequently, CT images of a hand, together with an anthropomorphic phantom, were voxelized and used with the MCNPX code for dose calculations. The hand dose distribution study was performed both by using thermo-luminescent detector measurements and Monte Carlo simulations. The validated simulation tool provides a new perspective for detailed investigations of CT-irradiation scenarios. Simulations show that there is a strong dose gradient, namely the even zones of the hand that are in precise vicinity to the x-ray beam only receive about 4% of the maximum dose delivered to adjacent areas which are directly exposed to the primary x-ray beam. Finally, the scatter contribution of the patient was also studied through MC simulations. The results show that for directly exposed parts of the hand surface, the dose is reduced by the body of the patient (due to the shielding), whereas the dose is increased by scattered radiation from the patient for parts of the skin that receive scattered radiation only.

  14. Performance evaluation of iterative reconstruction algorithms for achieving CT radiation dose reduction - a phantom study.

    Science.gov (United States)

    Dodge, Cristina T; Tamm, Eric P; Cody, Dianna D; Liu, Xinming; Jensen, Corey T; Wei, Wei; Kundra, Vikas; Rong, X John

    2016-03-08

    The purpose of this study was to characterize image quality and dose performance with GE CT iterative reconstruction techniques, adaptive statistical iterative recontruction (ASiR), and model-based iterative reconstruction (MBIR), over a range of typical to low-dose intervals using the Catphan 600 and the anthropomorphic Kyoto Kagaku abdomen phantoms. The scope of the project was to quantitatively describe the advantages and limitations of these approaches. The Catphan 600 phantom, supplemented with a fat-equivalent oval ring, was scanned using a GE Discovery HD750 scanner at 120 kVp, 0.8 s rotation time, and pitch factors of 0.516, 0.984, and 1.375. The mA was selected for each pitch factor to achieve CTDIvol values of 24, 18, 12, 6, 3, 2, and 1 mGy. Images were reconstructed at 2.5 mm thickness with filtered back-projection (FBP); 20%, 40%, and 70% ASiR; and MBIR. The potential for dose reduction and low-contrast detectability were evaluated from noise and contrast-to-noise ratio (CNR) measurements in the CTP 404 module of the Catphan. Hounsfield units (HUs) of several materials were evaluated from the cylinder inserts in the CTP 404 module, and the modulation transfer function (MTF) was calculated from the air insert. The results were con-firmed in the anthropomorphic Kyoto Kagaku abdomen phantom at 6, 3, 2, and 1mGy. MBIR reduced noise levels five-fold and increased CNR by a factor of five compared to FBP below 6mGy CTDIvol, resulting in a substantial improvement in image quality. Compared to ASiR and FBP, HU in images reconstructed with MBIR were consistently lower, and this discrepancy was reversed by higher pitch factors in some materials. MBIR improved the conspicuity of the high-contrast spatial resolution bar pattern, and MTF quantification confirmed the superior spatial resolution performance of MBIR versus FBP and ASiR at higher dose levels. While ASiR and FBP were relatively insensitive to changes in dose and pitch, the spatial resolution for MBIR

  15. Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

    Science.gov (United States)

    Su, Zhong; Zhang, Lisha; Ramakrishnan, V; Hagan, Michael; Anscher, Mitchell

    2011-05-01

    .5 mm. For hypothesis 2, analysis of variance indicated that there was no statistically significant difference between the dosimeter readings with and without the presence of transponders. Both orthogonal and parallel configurations had difference of polynomial-fit dose to measured dose values within 1.75%. The phantom study indicated that the Calypso System's localization accuracy was not affected clinically due to the presence of DVS wireless MOSFET dosimeters and the dosimeter-measured doses were not affected by the presence of transponders. Thus, the same patients could be implanted with both transponders and dosimeters to benefit from improved accuracy of radiotherapy treatments offered by conjunctional use of the two systems.

  16. A comparative study of strain and shear-wave elastography in an elasticity phantom

    DEFF Research Database (Denmark)

    Carlsen, Jonathan F.; Pedersen, Malene R; Ewertsen, Caroline

    2015-01-01

    OBJECTIVE. The purpose of this study was to assess the diagnostic accuracy of strain and shear-wave elastography for determining targets of varying stiffness in a phantom. The effect of target diameter on elastographic assessments and the effect of depth on shear-wave velocity were also...... investigated. MATERIALS AND METHODS. We examined 20 targets of varying diameters (2.5-16.7 mm) and stiffnesses (8, 14, 45, and 80 kPa) with a 4-9-MHz linear-array transducer. Targets were evaluated 10 times with three different methods-shear-wave elastography, strain ratio, and strain histogram analysis....... RESULTS. Strain ratio and strain histogram AUCs were higher than the shear-wave velocity AUC (p Strain ratios were superior (p = 0...

  17. Phantom breast and other syndromes after mastectomy: eight breast cancer patients describe their experiences over time: a 2-year follow-up study.

    Science.gov (United States)

    Björkman, Berit; Arnér, Staffan; Hydén, Lars-Christer

    2008-11-01

    Patients often experience hard-to-treat neuropathic pain and other sensations after surgery; consequently, they could develop chronic pain conditions. The phantom limb phenomenon is a well-documented postoperative pain condition. However, phantom phenomena after mastectomies are less documented. The reviews report several views on the prevalence of breast phantoms and coexisting distress. Researchers observed that new methodological approaches might facilitate further research of these issues. This prospective, qualitative study used semistructured interviews to acquire knowledge of if and how phantom breast phenomena appear within the range of other postmastectomy symptoms and sensations. The study revealed that a phantom breast could be difficult to describe and position spatially. The phantom breast phenomenon varied from classic phantom extremity phenomenon and did not seem to cause much distress. However, it proved to be a phenomenon so unknown and different that there is urgent need for more knowledge. This study highlights the importance of further investigation regarding how information and communication related to a phantom breast might be developed. The phantom breast is only one piece of a complicated puzzle. Because it was relatively unknown for the women in the study, it is important that analyses of this phenomenon, as a part of a postmastectomy syndrome, be conducted in a dialogue with the patients, by scientifically using qualitative methods.

  18. Dual-energy electronic cleansing for non-cathartic CT colonography: a phantom study

    Science.gov (United States)

    Cai, Wenli; Liu, Bob; Yoshida, Hiroyuki

    2010-03-01

    Partial volume effect and inhomogeneity are two major causes of artifacts in electronic cleansing (EC) for non-cathartic CT colonography (CTC). Our purpose was to develop a novel method of EC for non-cathartic dual-energy CTC (DECTC) using a subvoxel multi-spectral material classifier and a regional material decomposition method for differentiation of residual fecal materials from colonic soft-tissue structures. In this study, an anthropomorphic colon phantom, which was filled with a mixture of aqueous fiber (psyllium), ground foodstuff (cereal), and non-ionic iodinated agent (Omnipaque iohexol, GE Healthcare, Milwaukee, WI), was scanned by a dual-energy CT scanner (SOMATON, Siemens) with two photon energies: 80 kVp and 140 kVp. The DE-CTC images were subjected to a dual-energy EC (DE-EC) scheme, in which a multi-spectral material classifier was used to compute the fraction of each material within one voxel by an expectation-maximization (EM) algorithm. This was followed by a regional material segmentation method for identifying of homogeneous sub-regions (tiles) as fecal materials from other tissue types. The results were compared with the structural-analysis cleansing (SA-EC) method based upon the CTC images of native phantom without fillings. The mean cleansing ratio of the DE-EC scheme was 96.57+/-1.21% compared to 76.3+/-5.56% of the SA-EC scheme. The soft-tissue preservation ratio of the DE-EC scheme was 97.05%+/-0.64% compared to 99.25+/-0.77% of the SA-EC scheme.

  19. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Feng Shiting [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Law, Martin Wai-Ming [Department of Clinical Oncology, Queen Mary Hospital (Hong Kong); Huang Bingsheng [Department of Diagnostic Radiology, University of Hong Kong (Hong Kong); Ng, Sherry [Department of Clinical Oncology, Queen Mary Hospital (Hong Kong); Li Ziping; Meng Quanfei [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Khong, Pek-Lan, E-mail: plkhong@hkucc.hku.hk [Department of Diagnostic Radiology, University of Hong Kong (Hong Kong)

    2010-11-15

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  20. Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Hamersvelt, Robbert W. van; Schilham, Arnold M.R.; Harder, Annemarie M. den; Leiner, Tim; Jong, Pim A. de; Willemink, Martin J. [University Medical Centre Utrecht, Department of Radiology, P.O. Box 85500, Utrecht (Netherlands); Engelke, Klaus [University of Erlangen-Nuernberg, Institute of Medical Physics, Erlangen (Germany); Keizer, Bart de [University Medical Centre Utrecht, Department of Nuclear Medicine, Utrecht (Netherlands); Verhaar, Harald J. [University Medical Centre Utrecht, Department of Geriatric Medicine, Utrecht (Netherlands)

    2017-10-15

    To investigate the accuracy of bone mineral density (BMD) quantification using dual-layer spectral detector CT (SDCT) at various scan protocols. Two validated anthropomorphic phantoms containing inserts of 50-200 mg/cm{sup 3} calcium hydroxyapatite (HA) were scanned using a 64-slice SDCT scanner at various acquisition protocols (120 and 140 kVp, and 50, 100 and 200 mAs). Regions of interest (ROIs) were placed in each insert and mean attenuation profiles at monochromatic energy levels (90-200 keV) were constructed. These profiles were fitted to attenuation profiles of pure HA and water to calculate HA concentrations. For comparison, one phantom was scanned using dual energy X-ray absorptiometry (DXA). At both 120 and 140 kVp, excellent correlations (R = 0.97, P < 0.001) were found between true and measured HA concentrations. Mean error for all measurements at 120 kVp was -5.6 ± 5.7 mg/cm{sup 3} (-3.6 ± 3.2%) and at 140 kVp -2.4 ± 3.7 mg/cm{sup 3} (-0.8 ± 2.8%). Mean measurement errors were smaller than 6% for all acquisition protocols. Strong linear correlations (R{sup 2} ≥ 0.970, P < 0.001) with DXA were found. SDCT allows for accurate BMD quantification and potentially opens up the possibility for osteoporosis evaluation and opportunistic screening in patients undergoing SDCT for other clinical indications. However, patient studies are needed to extend and translate our findings. (orig.)

  1. Internal strain estimation for quantification of human heel pad elastic modulus: A phantom study

    DEFF Research Database (Denmark)

    Holst, Karen; Liebgott, Hervé; Wilhjelm, Jens E.

    2013-01-01

    heel phantoms were manufactured featuring a combination of three heel pad stiffnesses and three heel pad thicknesses to model the normal human variation. Each phantom was tested in an indentation system comprising a 7MHz linear array ultrasound transducer, working as the indentor, and a connected load....... Elastic moduli were found from the resulting stress–strain curves. The elastic moduli made it possible to distinguish eight of nine phantoms from each other according to the manufactured stiffness and showed very little dependence of the thickness. Mean elastic moduli for the three soft, the three medium...

  2. Study of the optical properties of solid tissue phantoms using single and double integrating sphere systems

    CSIR Research Space (South Africa)

    Monem, S

    2015-12-01

    Full Text Available Tissue simulators, the so-called tissue phantoms, have been used to mimic human tissue for spectroscopic applications. Phantoms’ design depends on patterning the optical properties, namely absorption and scattering coefficients which characterize...

  3. A Method for Manufacturing Oncological Phantoms for the Quantification of 18F-FDG PET and DW-MRI Studies

    Directory of Open Access Journals (Sweden)

    Francesca Gallivanone

    2017-01-01

    Full Text Available The aim of this work was to develop a method to manufacture oncological phantoms for quantitation purposes in 18F-FDG PET and DW-MRI studies. Radioactive and diffusion materials were prepared using a mixture of agarose and sucrose radioactive gels. T2 relaxation and diffusion properties of gels at different sucrose concentrations were evaluated. Realistic oncological lesions were created using 3D-printed plastic molds filled with the gel mixture. Once solidified, gels were extracted from molds and immersed in a low-radioactivity gel simulating normal background tissue. A breast cancer phantom was manufactured using the proposed method as an exploratory feasibility study, including several realistic oncological configurations in terms of both radioactivity and diffusion. The phantom was acquired in PET with 18F-FDG, immediately after solidification, and in DW-MRI the following day. Functional volumes characterizing the simulated BC lesions were segmented from PET and DW-MRI images. Measured radioactive uptake and ADC values were compared with gold standards. Phantom preparation was straightforward, and the time schedule was compatible with both PET and MRI measurements. Lesions appeared on 18F-FDG PET and DW-MRI images as expected, without visible artifacts. Lesion functional parameters revealed the phantom’s potential for validating quantification methods, in particular for new generation hybrid PET-MRI systems.

  4. Capsaicin 8% patch treatment for amputation stump and phantom limb pain: a clinical and functional MRI study.

    Science.gov (United States)

    Privitera, Rosario; Birch, Rolfe; Sinisi, Marco; Mihaylov, Iordan R; Leech, Robert; Anand, Praveen

    2017-01-01

    The aim of this study was to measure the efficacy of a single 60 min application of capsaicin 8% patch in reducing chronic amputation stump and phantom limb pain, associated hypersensitivity with quantitative sensory testing, and changes in brain cortical maps using functional MRI (fMRI) scans. A capsaicin 8% patch (Qutenza) treatment study was conducted on 14 patients with single limb amputation, who reported pain intensity on the Numerical Pain Rating Scale ≥4/10 for chronic stump or phantom limb pain. Pain assessments, quantitative sensory testing, and fMRI (for the lip pursing task) were performed at baseline and 4 weeks after application of capsaicin 8% patch to the amputation stump. The shift into the hand representation area of the cerebral cortex with the lip pursing task has been correlated with phantom limb pain intensity in previous studies, and was the fMRI clinical model for cortical plasticity used in this study. The mean reduction in spontaneous amputation stump pain, phantom limb pain, and evoked stump pain were -1.007 (p=0.028), -1.414 (p=0.018), and -2.029 (p=0.007), respectively. The areas of brush allodynia and pinprick hypersensitivity in the amputation stump showed marked decreases: -165 cm2, -80% (p=0.001) and -132 cm2, -72% (p=0.001), respectively. fMRI analyses provided objective evidence of the restoration of the brain map, that is, reversal of the shift into the hand representation of the cerebral cortex with the lip pursing task (pPhantom limb pain ("central" pain) and associated brain plasticity may be modulated by peripheral inputs, as they can be ameliorated by the peripherally restricted effect of the capsaicin 8% patch.

  5. Study of myocardial regional wall motion parameter's accuracy by software perfusion phantom.

    Science.gov (United States)

    Fidler, V; Fettich, J; Prepadnik, M

    1992-06-01

    Gated perfusion myocardial scintigraphy permits simultaneous evaluation of perfusion as well as regional contractile function of the left ventricle. Fourier analysis of regional myocardial spatial movement with respect to the myocardial geometric centre gives circular amplitude and phase profiles of ventricular contraction, in addition to regional maximum activity that represents an index of perfusion. To introduce such combined perfusion-contraction analysis the accuracy of the indices mentioned above should be evaluated for different doses of radioactivity typically administered to a patient. A mathematical software phantom, consisting of a half circularly profiled ring activity embedded in uniform background activity and noise generated by a Poisson-shaped random number generator, was constructed and used for this purpose. A 64 x 64 matrix and sequence of 16 frames per study was used. The maximum number of counts per pixel ranged from 10 to 100, simulating low count thallium and high count rate Tc-MIBI-gated studies. The relative standard error analysis (R.S.E.) with a 95.5% confidence level for a thallium type of 10 counts per pixel study exceeded 11%, while it reached acceptable values below 3% for studies with 60 and more counts per pixel. These results indicate that high count rate gated technetium-MIBI myocardial perfusion studies could also be used for reliable left ventricular regional wall motion evaluation.

  6. Comparison of image quality between mammography dedicated monitor and UHD 4K monitor, using standard mammographic phantom: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Young; Cha, Soon Joo; Hong, Sung Hwan; Kim, Su Young; Kim, Yong Hoon; Kim, You Sung; Kim, Jeong A [Dept. of Radiology, Inje Unveristy Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2017-03-15

    Using standard mammographic phantom images, we compared the image quality obtained between a mammography dedicated 5 megapixel monitor (5M) and a UHD 4K (4K) monitor with digital imaging and communications in medicine display, to investigate the possibility of clinical application of 4K monitors. Three different exposures (autoexposure, overexposure and underexposure) images of mammographic phantom were obtained, and six radiologists independently evaluated the images in 5M and 4K without image modulation, by scoring of fibers, groups of specks and masses within the phantom image. The mean score of each object on both monitors was independently analyzed, using t-test and interobserver reliability by intraclass correlation coefficient (ICC) of SPSS. The overall mean scores of fiber, group of specks, and mass in 5M were 4.25, 3.92, and 3.28 respectively, and scores obtained in 4K monitor were 3.81, 3.58, and 3.14, respectively. No statistical difference was seen in scores of fiber and mass between the two monitors at all exposure conditions, but the score of group of specks in 4K was statistically lower in the overall (p = 0.0492) and in underexposure conditions (p = 0.012). The ICC for interobserver reliability was excellent (0.874). Our study suggests that since the mammographic phantom images are appropriate with no significant difference in image quality observed between the two monitors, the 4K monitor could be used for clinical studies. Since this is a small preliminary study using phantom images, the result may differ in actual mammographic images, and subsequent investigation with clinical mammographic images is required.

  7. Comparison of 3DCRT,VMAT and IMRT techniques in metastatic vertebra radiotherapy: A phantom Study

    Science.gov (United States)

    Gedik, Sonay; Tunc, Sema; Kahraman, Arda; Kahraman Cetintas, Sibel; Kurt, Meral

    2017-09-01

    Vertebra metastases can be seen during the prognosis of cancer patients. Treatment ways of the metastasis are radiotherapy, chemotherapy and surgery. Three-dimensional conformal therapy (3D-CRT) is widely used in the treatment of vertebra metastases. Also, Intensity Modulated Radiotherapy (IMRT) and Volumetric Arc Therapy (VMAT) are used too. The aim of this study is to examine the advantages and disadvantages of the different radiotherapy techniques. In the aspect of this goal, it is studied with a randophantom in Uludag University Medicine Faculty, Radiation Oncology Department. By using a computerized tomography image of the phantom, one 3DCRT plan, two VMAT and three IMRT plans for servical vertebra and three different 3DCRT plans, two VMAT and two IMRT plans for lomber vertebra are calculated. To calculate 3DCRT plans, CMS XiO Treatment System is used and to calculate VMAT and IMRT plans Monaco Treatment Planning System is used in the department. The study concludes with the dosimetric comparison of the treatment plans in the spect of critical organ doses, homogeneity and conformity index. As a result of this study, all critical organ doses are suitable for QUANTEC Dose Limit Report and critical organ doses depend on the techniques which used in radiotherapy. According to homogeneity and conformity indices, VMAT and IMRT plans are better than one in 3DCRT plans in servical and lomber vertebra radiotherapy plans.

  8. A feasibility study of temperature rise measurement in a tissue phantom as an alternative way for characterization of the therapeutic high intensity focused ultrasonic field.

    Science.gov (United States)

    Chen, Di; Fan, Tingbo; Zhang, Dong; Wu, Junru

    2009-12-01

    The feasibility that temperature field measurements in vitro as an alternative way to characterize the high intensity focused ultrasound (HIFU) field used in therapeutic applications has been explored in a phantom study. Thermocouples (copper-constantan, diameter 0.125 mm) are embedded in a phantom filled with tissue mimicking material that simulates the thermal and acoustic properties of soft-tissue. The temperature rises as a function of ultrasound exposure time near the focus of a HIFU transducer (1.1 MHz, active radius a=32 mm, geometric focal length=62 mm) of various acoustic powers up to 30 W are measured and compared with predicted values using a simple nonlinear Gaussian model. The experimental results can be explained well by the model if no acoustic cavitation takes place. When the acoustic power become higher (>5 W) and the local temperature elevation >15 degrees C and the local temperature is >40 degrees C at the focal point, cavitation vapor bubbles appear. The presence of the cavitation bubbles may increase the temperature rise rate initially. The bubble aggregates may form along the beam axis under sonication and then eventually makes the temperature elevation reach a saturated value. When acoustic cavitation occurs, the bubble-assisted enhancement of the initial temperature rise (exposure time t<2s) can still be predicted by the theory.

  9. Phantom movements from physiologically inappropriate muscles: A case study with a high transhumeral amputee.

    Science.gov (United States)

    Gade, Julie; Hugosdottir, Rosa; Kamavuako, Ernest N

    2015-08-01

    Individuals with high-level amputation have a great need for functional prostheses because of their vast functional deficits. Conventional techniques are considered inappropriate for high-level amputees due to the lack of physiologically appropriate muscles. This study investigates how accurate phantom movements (PMs) can be classified from physiologically inappropriate muscles. The study involves a case study of a 42-year-old transhumeral amputee. Suitable PMs and best electrode configuration were identified using the sequential forward selection method and brute-force technique. Using linear discriminant analysis, the best PMs (elbow extension/flexion, wrist supination/pronation) and rest were classified with error ranging from 3% to 0.18% when using 3 to 8 EMG channels respectively. A completion rate of 93 % was obtained during a targeted achievement control test in a virtual reality environment. This case indicates that a proximal transhumeral amputee can generate muscle activation patterns related to distinct PMs; and these PMs can be decoded from physiologically inappropriate muscles.

  10. In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study.

    Science.gov (United States)

    Shao, Yiping; Sun, Xishan; Lou, Kai; Zhu, Xiaorong R; Mirkovic, Dragon; Poenisch, Falk; Grosshans, David

    2014-07-07

    We developed and investigated a positron emission tomography (PET) system for use with on-line (both in-beam and intra-fraction) image-guided adaptive proton therapy applications. The PET has dual rotating depth-of-interaction measurable detector panels by using solid-state photomultiplier (SSPM) arrays and LYSO scintillators. It has a 44 mm diameter trans-axial and 30 mm axial field-of-view (FOV). A 38 mm diameter polymethyl methacrylate phantom was placed inside the FOV. Both PET and phantom axes were aligned with a collimated 179.2 MeV beam. Each beam delivered ∼50 spills (0.5 s spill and 1.5 s inter-spill time, 3.8 Gy at Bragg peak). Data from each beam were acquired with detectors at a given angle. Nine datasets for nine beams with detectors at nine different angles over 180° were acquired for full-tomographic imaging. Each dataset included data both during and 5 min after irradiations. The positron activity-range was measured from the PET image reconstructed from all nine datasets and compared to the results from simulated images. A (22)Na disc-source was also imaged after each beam to monitor the PET system's performance. PET performed well except for slight shifts of energy photo-peak positions (beam, due mainly to the neutron exposure of SSPM that increased the dark-count noise. This minor effect was corrected offline with a shifting 350-650 keV energy window for each dataset. The results show a fast converging of activity-ranges measured by the prototype PET with high sensitivity and uniform resolution. Sub-mm activity-ranges were achieved with minimal 6 s acquisition time and three spill irradiations. These results indicate the feasibility of PET for intra-fraction beam-range verification. Further studies are needed to develop and apply a novel clinical PET system for on-line image-guided adaptive proton therapy.

  11. Nanoparticle-mediated radiofrequency capacitive hyperthermia: A phantom study with magnetic resonance thermometry.

    Science.gov (United States)

    Kim, Ki Soo; Lee, Soo Yeol

    2015-01-01

    In hyperthermia, focusing heat generation on tumour tissues and precisely monitoring the temperature around the tumour region is important. To focus heat generation in radiofrequency (RF) capacitive heating, magnetic nanoparticles suspended in sodium carboxymethyl cellulose (CMC) solution were used, based on the hypothesis that the nanoparticle suspension would elevate electrical conductivity and RF current density at the nanoparticle-populated region. A tissue-mimicking phantom with compartments with and without nanoparticles was made for RF capacitive heating experiments. An FDTD model of the phantom was developed to simulate temperature increases at the phantom. To monitor temperature inside the phantom, MR thermometry was performed intermittently during RF heating inside a 3Tesla MRI magnet bore. FDTD simulation on the phantom model was performed in two steps: electromagnetic simulation to compute specific absorption rate and thermal simulation to compute temperature changes. Experimental temperature maps were similar to simulated temperature maps, demonstrating that nanoparticle-populated regions drew more heat than background regions. Nanoparticle-mediated RF heating could mitigate concerns about normal tissue death during RF capacitive hyperthermia.

  12. Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study.

    Science.gov (United States)

    Bazalova-Carter, Magdalena; Ahmad, Moiz; Xing, Lei; Fahrig, Rebecca

    2015-10-01

    Thanks to the current advances in nanoscience, molecular biochemistry, and x-ray detector technology, x-ray fluorescence computed tomography (XFCT) has been considered for molecular imaging of probes containing high atomic number elements, such as gold nanoparticles. The commonly used XFCT imaging performed with K-shell x rays appears to have insufficient imaging sensitivity to detect the low gold concentrations observed in small animal studies. Low energy fluorescence L-shell x rays have exhibited higher signal-to-background ratio and appeared as a promising XFCT mode with greatly enhanced sensitivity. The aim of this work was to experimentally demonstrate the feasibility of L-shell XFCT imaging and to assess its achievable sensitivity. We built an experimental L-shell XFCT imaging system consisting of a miniature x-ray tube and two spectrometers, a silicon drift detector (SDD), and a CdTe detector placed at [Formula: see text] with respect to the excitation beam. We imaged a 28-mm-diameter water phantom with 4-mm-diameter Eppendorf tubes containing gold solutions with concentrations of 0.06 to 0.1% Au. While all Au vials were detectable in the SDD L-shell XFCT image, none of the vials were visible in the CdTe L-shell XFCT image. The detectability limit of the presented L-shell XFCT SDD imaging setup was 0.007% Au, a concentration observed in small animal studies.

  13. Preliminary study of slow and fast ultrasonic waves using MR images of trabecular bone phantom

    Energy Technology Data Exchange (ETDEWEB)

    Solis-Najera, S. E., E-mail: solisnajera@ciencias.unam.mx, E-mail: angel.perez@ciencias.unam.mx, E-mail: lucia.medina@ciencias.unam.mx; Neria-Pérez, J. A., E-mail: solisnajera@ciencias.unam.mx, E-mail: angel.perez@ciencias.unam.mx, E-mail: lucia.medina@ciencias.unam.mx; Medina, L., E-mail: solisnajera@ciencias.unam.mx, E-mail: angel.perez@ciencias.unam.mx, E-mail: lucia.medina@ciencias.unam.mx [Facultad de Ciencias, Universidad Nacional Autónoma de México, México, DF 04510 (Mexico); Garipov, R., E-mail: ruslan.garipov@mrsolutions.co.uk [MR Solutions Ltd, Surrey (United Kingdom); Rodríguez, A. O., E-mail: arog@xanum.uam.mx [Departamento Ingeniería Eléctrica, Universidad Autónoma Metropolitana Iztapalapa, México, DF 09340 (Mexico)

    2014-11-07

    Cancellous bone is a complex tissue that performs physiological and biomechanical functions in all vertebrates. It is made up of trabeculae that, from a simplified structural viewpoint, can be considered as plates and beams in a hyperstatic structure that change with time leading to osteoporosis. Several methods has been developed to study the trabecular bone microstructure among them is the Biot’s model which predicts the existence of two longitudinal waves in porous media; the slow and the fast waves, that can be related to porosity of the media. This paper is focused on the experimental detection of the two Biot’s waves of a trabecular bone phantom, consisting of a trabecular network of inorganic hydroxyapatite. Experimental measurements of both waves were performed using through transmission ultrasound. Results had shown clearly that the propagation of two waves propagation is transversal to the trabecular alignment. Otherwise the waves are overlapped and a single wave seems to be propagated. To validate these results, magnetic resonance images were acquired to assess the trabecular direction, and to assure that the pulses correspond to the slow and fast waves. This approach offers a methodology for non-invasive studies of trabecular bones.

  14. The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

    Science.gov (United States)

    Yang, Jaewon; Yamamoto, Tokihiro; Cho, Byungchul; Seo, Youngho; Keall, Paul J

    2012-02-01

    Irregular breathing causes motion blurring artifacts in 4D PET images. Audiovisual (AV) biofeedback has been demonstrated to improve breathing regularity. To investigate the hypothesis that, compared with free breathing, motion blurring artifacts are reduced with AV biofeedback, the authors performed the first experimental phantom-based quantification of the impact of AV biofeedback on 4D PET image quality. The authors acquired 4D PET dynamic phantom images with AV biofeedback and free breathing by moving a phantom programmed with AV biofeedback trained and free breathing respiratory traces of ten healthy subjects. The authors also acquired stationary phantom images for reference. The phantom was cylindrical with six hollow sphere targets (10, 13, 17, 22, 28, and 37 mm in diameter). The authors quantified motion blurring using the target diameter, Dice coefficient and recovery coefficient (RC) metrics to estimate the effect of motion. The average increase in target diameter for AV biofeedback was 0.6±1.6mm (4.7±13%), which was significantly (pimpact of target sizes was more dominant than that of motion. In addition, the authors observed large variations in the results with respect to target sizes, subject traces and respiratory bins due to partial volume effects and respiratory motion irregularity. The results indicate that AV biofeedback can significantly reduce motion blurring artifacts and may facilitate improved identification and localization of lung tumors in 4D PET images. The results justify proceeding with clinical studies to quantify the impact of AV biofeedback on 4D PET image quality and tumor detectability.

  15. Evaluation of exposure dose to patients undergoing catheter ablation procedures - a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Seguchi, S. [Nagoya University, Graduate School of Medicine, Nagoya (Japan); Nagoya Daini Red Cross Hospital, Division of Radiology, Department of Medical Technology, Nagoya (Japan); Aoyama, T.; Koyama, S.; Kawaura, C. [Nagoya University, Graduate School of Medicine, Nagoya (Japan); Fujii, K. [Nagoya University, Graduate School of Medicine, Nagoya (Japan); National Institute of Radiological Sciences, Section of Radiological Protection, Chiba (Japan)

    2008-11-15

    The aim of this study was to evaluate entrance skin dose (ESD), organ dose and effective dose to patients undergoing catheter ablation for cardiac arrhythmias, based on the dosimetry in an anthropomorphic phantom. ESD values associated with mean fluoroscopy time and digital cine frames were in a range of 0.12-0.30 Gy in right anterior oblique (RAO) and 0.05-0.40 Gy in left anterior oblique (LAO) projection, the values which were less than a threshold dose of 2 Gy for the onset of skin injury. Organs that received high doses in ablation procedures were lung, followed by bone surface, esophagus, liver and red bone marrow. Doses for lung were 24.8-122.7 mGy, and effective doses were 7.9-34.8 mSv for mean fluoroscopy time of 23.4-92.3 min and digital cine frames of 263-511. Conversion coefficients of dose-area product (DAP) to ESD were 8.7 mGy/(Gy.cm{sup 2}) in RAO and 7.4 mGy/(Gy.cm{sup 2}) in LAO projection. The coefficients of DAP to the effective dose were 0.37 mSv/(Gy.cm{sup 2}) in RAO, and 0.41 mSv/(Gy.cm{sup 2}) in LAO projection. These coefficients enabled us to estimate patient exposure in real time by using monitored values of DAP. (orig.)

  16. Dose profile study in head CT scans using a male anthropomorphic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Alvaro M.L.; Santana, Priscila do C.; Mourao, Arnaldo P., E-mail: amlgphys@gmail.com, E-mail: pridili@gmail.com, E-mail: apratabhz@gmail.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    Computed tomography (CT) test is an efficient and non-invasive method to obtain data about internal structures of the human body. CT scans contribute with the highest absorbed doses in population due X-ray beam attenuation and it has raised concern in radiosensitive tissues. Techniques for the optimization of CT scanning protocols in diagnostic services have been developing with the objective of decreasing the absorbed dose in the patient, aiming image quality within acceptable parameters for diagnosis by noise control. Routine head scans were performed using GE CT scan of 64 channels programmed with automatic exposure control and voltages of 80, 100 and 120 kV attaching the noise index in approximately 0.5%, using the tool of smart mA. An anthropomorphic adult male phantom was used and radiochromic film strips were placed to measure the absorbed dose deposited in areas such as the lens, thyroid and pituitary for study of dose deposited in these important areas containing high radiosensitive tissues. Different head scans were performed using optimized values of mA.s for the different voltages. The absorbed dose measured by the film strips were in the range of the 0.58 and 44.36 mGy. The analysis of noise in the images is within the acceptable levels for diagnosis, and the optimized protocol happens with the voltage of 100 kV. The use of other voltage values can allow obtain better protocols for head scans. (author)

  17. The response of MRI contrast parameters in in vitro tissues and tissue mimicking phantoms to fractionation by histotripsy

    Science.gov (United States)

    Allen, Steven P.; Vlaisavljevich, Eli; Shi, Jiaqi; Hernandez-Garcia, Luis; Cain, Charles A.; Xu, Zhen; Hall, Timothy L.

    2017-09-01

    Histotripsy is a non-invasive, focused ultrasound lesioning technique that can ablate precise volumes of soft tissue using a novel mechanical fractionation mechanism. Previous research suggests that magnetic resonance imaging (MRI) may be a sensitive image-based feedback mechanism for histotripsy. However, there are insufficient data to form some unified understanding of the response of the MR contrast mechanisms in tissues to histotripsy. In this paper, we investigate the response of the MR contrast parameters R1, R2, and the apparent diffusion coefficient (ADC) to various treatment levels of histotripsy in in vitro porcine liver, kidney, muscle, and blood clot as well in formulations of bovine red blood cells suspended in agar gel. We also make a histological analysis of histotripsy lesions in porcine liver. We find that R2 and the ADC are both sensitive to ablation in all materials tested here, and the degree of response varies with tissue type. Correspondingly, under histologic analysis, the porcine liver exhibited various levels of mechanical disruption and necrotic debris that are characteristic of histotripsy. While the area of intact red blood cells and nuclei found within these lesions both decreased with increasing amounts of treatment, the area of red blood cells decreased much more rapidly than the area of intact nuclei. Additionally, the decrease in area of intact red blood cells saturated at the same treatment levels at which the response of the R2 saturated while the area of intact nuclei appeared to vary linearly with the response of the ADC.

  18. Pre-evaluation study in SPECT images using a phantom; Avaliacao do pre processamento das projecoes em SPECT com phantom fisico

    Energy Technology Data Exchange (ETDEWEB)

    Rebelo, Marina de Sa; Furuie, Sergio Shiguemi [Sao Paulo Univ., SP (Brazil). Instituto do Coracao. Div. de Informatica; Abe, Rubens [Sao Paulo Univ., SP (Brazil). Instituto do Coracao. Servico de Radioisotopos; Moura, Lincoln [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    1996-12-31

    An alternative solution for the reconstruction of SPECT images using a Poisson Noise Model is presented. The proposed algorithm was applied on a real phantom and compared to the standard clinical procedures. Results have shown that the proposed method improves the quality of the SPECT images 3 refs.

  19. MR pulse sequences for selective relaxation time measurements: a phantom study

    DEFF Research Database (Denmark)

    Thomsen, C; Jensen, K E; Jensen, M

    1990-01-01

    The accuracy of relaxation time measurements of spectroscopic inversion recovery and CPMG multi-echo pulse sequences together with ISIS and stimulated echo-pulse methods have been tested on a reference phantom (test object no. 5, of the EEC Concerted Research Project). For the measurements...... a Siemens Magnetom wholebody magnetic resonance scanner operating at 1.5 Tesla was used. For comparison six imaging pulse sequences for relaxation time measurements were tested on the same phantom. The spectroscopic pulse sequences all had an accuracy better than 10% of the reference values....

  20. A phantom study on temporal and subband Minimum Variance adaptive beamforming

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Voxen, Iben Holfort; Greenaway, Alan H.

    2014-01-01

    This paper compares experimentally temporal and subband implementations of the Minimum Variance (MV) adaptive beamformer for medical ultrasound imaging. The performance of the two approaches is tested by comparing wire phantom measurements, obtained by the research ultrasound scanner SARUS. A 7 MHz...... BK8804 linear transducer was used to scan a wire phantom in which wires are separated by 10 mm. Performance is then evaluated by the lateral Full-Width-Half-Maximum (FWHM), the Peak Sidelobe Level (PSL), and the computational load. Beamformed single emission responses are also compared with those...

  1. Segmentation and quantification of materials with energy discriminating computed tomography: a phantom study.

    Science.gov (United States)

    Le, Huy Q; Molloi, Sabee

    2011-01-01

    To experimentally investigate whether a computed tomography (CT) system based on CdZnTe (CZT) detectors in conjunction with a least-squares parameter estimation technique can be used to decompose four different materials. The material decomposition process was divided into a segmentation task and a quantification task. A least-squares minimization algorithm was used to decompose materials with five measurements of the energy dependent linear attenuation coefficients. A small field-of-view energy discriminating CT system was built. The CT system consisted of an x-ray tube, a rotational stage, and an array of CZT detectors. The CZT array was composed of 64 pixels, each of which is 0.8 x 0.8 x 3 mm. Images were acquired at 80 kVp in fluoroscopic mode at 50 ms per frame. The detector resolved the x-ray spectrum into energy bins of 22-32, 33-39, 40-46, 47-56, and 57-80 keV. Four phantoms were constructed from polymethylmethacrylate (PMMA), polyethylene, polyoxymethylene, hydroxyapatite, and iodine. Three phantoms were composed of three materials with embedded hydroxyapatite (50, 150, 250, and 350 mg/ml) and iodine (4, 8, 12, and 16 mg/ml) contrast elements. One phantom was composed of four materials with embedded hydroxyapatite (150 and 350 mg/ml) and iodine (8 and 16 mg/ml). Calibrations consisted of PMMA phantoms with either hydroxyapatite (100, 200, 300, 400, and 500 mg/ml) or iodine (5, 15, 25, 35, and 45 mg/ml) embedded. Filtered backprojection and a ramp filter were used to reconstruct images from each energy bin. Material segmentation and quantification were performed and compared between different phantoms. All phantoms were decomposed accurately, but some voxels in the base material regions were incorrectly identified. Average quantification errors of hydroxyapatite/iodine were 9.26/7.13%, 7.73/5.58%, and 12.93/8.23% for the three-material PMMA, polyethylene, and polyoxymethylene phantoms, respectively. The average errors for the four-material phantom were 15

  2. Comparative study of shortwave heating patterns in phantoms with polyethylene and silk partitions.

    Science.gov (United States)

    Moon, C Y; Kantor, G; Athey, T W; Ho, H S

    1988-01-01

    Specific absorption rate (SAR) and effective depths of heating patterns induced by a shortwave, pancake diathermy applicator in fat-muscle phantom are measured. Midplane partitions of polyethylene and silk screen with and without contact chemicals are used. Thermographically obtained SAR data show nearly the same value for silk-screen partitions with and without contact chemicals and slightly lower values with polyethylene partitions, provided that the partition midplanes are tightly pressed against each other. Thermometry data indicate that for low-power exposures the major error in thermographic measurements obtained after termination of heating is due to thermal diffusion and not evaporative cooling in the opened midplane of the phantom.

  3. Capsaicin 8% patch treatment for amputation stump and phantom limb pain: a clinical and functional MRI study

    Directory of Open Access Journals (Sweden)

    Privitera R

    2017-07-01

    Full Text Available Rosario Privitera,1 Rolfe Birch,1 Marco Sinisi,2 Iordan R Mihaylov,3 Robert Leech,4 Praveen Anand1 1Peripheral Neuropathy Unit, Centre for Clinical Translation, Hammersmith Hospital, Imperial College London, London, UK; 2Peripheral Nerve Injury Unit, Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK; 3Department of Pain Medicine, Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK; 4Computational, Cognitive and Clinical Neuroimaging Laboratory, Division of Brain Sciences, Imperial College London, Hammersmith Hospital Campus, London, UK Purpose: The aim of this study was to measure the efficacy of a single 60 min application of capsaicin 8% patch in reducing chronic amputation stump and phantom limb pain, associated hypersensitivity with quantitative sensory testing, and changes in brain cortical maps using functional MRI (fMRI scans. Methods: A capsaicin 8% patch (Qutenza treatment study was conducted on 14 patients with single limb amputation, who reported pain intensity on the Numerical Pain Rating Scale ≥4/10 for chronic stump or phantom limb pain. Pain assessments, quantitative sensory testing, and fMRI (for the lip pursing task were performed at baseline and 4 weeks after application of capsaicin 8% patch to the amputation stump. The shift into the hand representation area of the cerebral cortex with the lip pursing task has been correlated with phantom limb pain intensity in previous studies, and was the fMRI clinical model for cortical plasticity used in this study. Results: The mean reduction in spontaneous amputation stump pain, phantom limb pain, and evoked stump pain were −1.007 (p=0.028, −1.414 (p=0.018, and −2.029 (p=0.007, respectively. The areas of brush allodynia and pinprick hypersensitivity in the amputation stump showed marked decreases: −165 cm2, −80% (p=0.001 and −132 cm2, −72% (p=0.001, respectively. fMRI analyses provided objective evidence of the restoration of the brain map, that is

  4. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    OpenAIRE

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T

    2011-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomograp...

  5. SU-E-T-507: Internal Dosimetry in Nuclear Medicine Using GATE and XCAT Phantom: A Simulation Study

    Energy Technology Data Exchange (ETDEWEB)

    Fallahpoor, M; Abbasi, M [Tehran University of Medical Sciences, Vali-Asr Hospital, Tehran, Tehran (Iran, Islamic Republic of); Sen, A [University of Houston, Houston, TX (United States); Parach, A [Shahid Sadoughi University of Medical Sciences, Yazd, Yazd (Iran, Islamic Republic of); Kalantari, F [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose Monte Carlo simulations are routinely used for internal dosimetry studies. These studies are conducted with humanoid phantoms such as the XCAT phantom. In this abstract we present the absorbed doses for various pairs of source and target organs using three common radiotracers in nuclear medicine. Methods The GATE software package is used for the Monte Carlo simulations. A typical female XCAT phantom is used as the input. Three radiotracers 153Sm, 131I and 99mTc are studied. The Specific Absorbed Fraction (SAF) for gamma rays (99mTc, 153Sm and 131I) and Specific Fraction (SF) for beta particles (153Sm and 131I) are calculated for all 100 pairs of source target organs including brain, liver, lung, pancreas, kidney, adrenal, spleen, rib bone, bladder and ovaries. Results The source organs themselves gain the highest absorbed dose as compared to other organs. The dose is found to be inversely proportional to distance from the source organ. In SAF results of 153Sm, when the source organ is lung, the rib bone, gain 0.0730 (Kg-1) that is more than lung itself. Conclusion The absorbed dose for various organs was studied in terms of SAF and SF. Such studies hold importance for future therapeutic procedures and optimization of induced radiotracer.

  6. A Movable Phantom Design for Quantitative Evaluation of Motion Correction Studies on High Resolution PET Scanners

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Svarer, C.; Sibomana, M.

    2010-01-01

    maximization algorithm with modeling of the point spread function (3DOSEM-PSF), and they were corrected for motions based on external tracking information using the Polaris Vicra real-time stereo motion-tracking system. The new automatic, movable phantom has a robust design and is a potential quality...

  7. Coronary calcium scores are systematically underestimated at a large chest size : A multivendor phantom study

    NARCIS (Netherlands)

    Willemink, Martin J.; Abramiuc, Bronislaw; den Harder, Annemarie M.; van der Werf, Niels R.; de Jong, Pim A.; Budde, Ricardo P. J.; Wildberger, Joachim E.; Vliegenthart, Rozemarijn; Willems, Tineke P.; Greuter, Marcel J. W.; Leiner, Tim

    2015-01-01

    Objective: To evaluate the effect of chest size on coronary calcium score (CCS) as assessed with new-generation CT systems from 4 major vendors. Methods: An anthropomorphic, small-sized (300 x 200 mm) chest phantom containing 100 small calcifications (diameters, 0.5-2.0 mm) was evaluated with and

  8. Coronary calcium scores are systematically underestimated at a large chest size : A multivendor phantom study

    NARCIS (Netherlands)

    Willemink, Martin J.; Abramiuc, Bronislaw; den Harder, Annemarie M.; van der Werf, Niels R.; de Jong, Pim A.; Budde, Ricardo P J; Wildberger, Joachim E.; Vliegenthart, Rozemarijn; Willems, Tineke P.; Greuter, Marcel J W; Leiner, Tim

    2015-01-01

    Objective: To evaluate the effect of chest size on coronary calcium score (CCS) as assessed with new-generation CT systems from 4 major vendors. Methods: An anthropomorphic, small-sized (300 × 200 mm) chest phantom containing 100 small calcifications (diameters, 0.5-2.0 mm) was evaluated with and

  9. Impact of low-dose CT scan in dual timepoint investigations: a phantom study

    DEFF Research Database (Denmark)

    Micheelsen, M A; Jensen, Mikael

    2011-01-01

    compromising attenuation correction, lesion detection and quantification. Using a standard NEMA phantom with the GE Discovery PET/CT scanner, taken in and out between scan sessions, we have tried to find the minimal CT dose necessary for the second scan while still reaching tissue activity quantification...

  10. A skull-based multiple dipole phantom for EEG and MEG studies

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, M.E.; Leahy, R.M. [University of Southern California, Los Angeles, CA (United States); Mosher, J.C. [Los Alamos National Lab., NM (United States)

    1996-07-01

    A versatile phantom for use in evaluating forward and inverse methods for MEG and EEG has been designed and is currently being constructed. The phantom consists of three major components: (i) a 32-element cur- rent dipole array, (ii) a PC-controlled dipole driver with 32 isolated channels allowing independent control of each dipole, (iii) spherical and human-skull mounts in which the dipole array is placed. Materials were selected throughout the phantom to produce minimal field distortions and artifacts to enable acquisition of high quality EEG and MEG data. The dipoles are made from a rigid narrow (0.84 mm) stainless steel coax cable. The dipole drivers can be configured as either current or voltage sources, are independently programmable and fully isolated, and are capable of producing arbitrary bipolar waveforms up to a 200 Hz bandwidth. The spherical mount is a single shell sphere filled with conductive gelatin. The human skull mount has three shells: ``brain`` (conducting gelatin), ``skull`` (the skull is impregnated with a low conductivity conducting gelatin), and ``scalp`` (a thin layer of rubber latex mixed with NaCl to achieve a conductivity matched to the brain). The conductivities will be adjusted to achieve approximately an 80:1:80 ratio. Data collected to date from the spherical phantom shows excellent agreement between measured surface potentials and that predicted from theory (27 of the 32 dipoles give better than 99.9% rms fit) and negligible leakage between dipoles. We are currently completing construction of the skull mount.

  11. Evaluation of biexponential relaxation processes by magnetic resonance imaging. A phantom study

    DEFF Research Database (Denmark)

    Kjaer, L; Thomsen, C; Larsson, H B

    1988-01-01

    .5 tesla (T). Measurements were performed on a phantom of bicompartmental perspex boxes with combinations of different CuSO4 concentrations. T1 determination was based on a 12-points partial saturation inversion recovery pulse sequence. T2 determination was provided by a multiple spin echo sequence with 32...

  12. Quantitative three-dimensional elasticity imaging from quasi-static deformation: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Michael S [Department of Radiology, University of Michigan Health System, Ann Arbor, MI 48109 (United States); Barbone, Paul E [Aerospace and Mechanical Engineering Department, Boston University, Boston, MA 02215 (United States); Oberai, Assad A [Department of Mechanical, Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 (United States)], E-mail: msrichar@umich.edu, E-mail: barbone@bu.edu, E-mail: oberaa@rpi.edu

    2009-02-07

    We present a methodology to image and quantify the shear elastic modulus of three-dimensional (3D) breast tissue volumes held in compression under conditions similar to those of a clinical mammography system. Tissue phantoms are made to mimic the ultrasonic and mechanical properties of breast tissue. Stiff lesions are created in these phantoms with size and modulus contrast values, relative to the background, that are within the range of values of clinical interest. A two-dimensional ultrasound system, scanned elevationally, is used to acquire 3D images of these phantoms as they are held in compression. From two 3D ultrasound images, acquired at different compressed states, a three-dimensional displacement vector field is measured. The measured displacement field is then used to solve an inverse problem, assuming the phantom material to be an incompressible, linear elastic solid, to recover the shear modulus distribution within the imaged volume. The reconstructed values are then compared to values measured independently by direct mechanical testing.

  13. Developing an acupuncture protocol for treating phantom limb pain: a Delphi consensus study.

    Science.gov (United States)

    Trevelyan, Esmé G; Turner, Warren A; Robinson, Nicola

    2015-02-01

    Little is known about how a Traditional Chinese Medicine (TCM) approach could be used to treat phantom limb pain (PLP). There is currently no standard acupuncture protocol in the literature to treat this syndrome. To achieve consensus among a group of acupuncture practitioners on the pathology and recommended treatment of PLP and devise an acupuncture protocol for the treatment of this condition. A classical Delphi approach was used using two parallel online Delphi studies. One study focused on participants with past experience of treating PLP (TPLP, n=7) and the other on practitioners with no past experience (NTPLP, n=16). Two hypothetical case studies were provided and participants were asked for responses on how they would treat these patients. Three rounds were included. Participants were also invited to rate and comment on the finalised protocol. Round 1 data were analysed using content analysis. In subsequent rounds an a priori criterion for defining consensus was set at ≤1.75 IQR. A group median of 5-6 was considered to mean 'agree'. 19 participants completed all Delphi rounds (12 NTPLP, 7 TPLP). 108 NTPLP and 76 TPLP statements were generated and circulated in round 2; 53% of the NTPLP statements and 62% of the TPLP statements met consensus in round 2 and 45% of the NTPLP statements and 44% of the TPLP statements met consensus in round 3. Participants all agreed with the final protocol developed. The protocol developed does not claim to be best practice but provides a preliminary consensus from practitioners practising acupuncture for the treatment of PLP. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Electrical impedance spectroscopy (EIS)-based evaluation of biological tissue phantoms to study multifrequency electrical impedance tomography (Mf-EIT) systems

    KAUST Repository

    Bera, Tushar Kanti

    2016-03-18

    Abstract: Electrical impedance tomography (EIT) phantoms are essential for the calibration, comparison and evaluation of the EIT systems. In EIT, the practical phantoms are typically developed based on inhomogeneities surrounded by a homogeneous background to simulate a suitable conductivity contrast. In multifrequency EIT (Mf-EIT) evaluation, the phantoms must be developed with the materials which have recognizable or distinguishable impedance variations over a wide range of frequencies. In this direction the impedance responses of the saline solution (background) and a number vegetable and fruit tissues (inhomogeneities) are studied with electrical impedance spectroscopy (EIS) and the frequency responses of bioelectrical impedance and conductivity are analyzed. A number of practical phantoms with different tissue inhomogeneities and different inhomogeneity configurations are developed and the multifrequency impedance imaging is studied with the Mf-EIT system to evaluate the phantoms. The conductivity of the vegetable inhomogeneities reconstructed from the EIT imaging is compared with the conductivity values obtained from the EIS studies. Experimental results obtained from multifrequency EIT reconstruction demonstrate that the electrical impedance of all the biological tissues inhomogenity decreases with frequency. The potato tissue phantom produces better impedance image in high frequency ranges compared to the cucumber phantom, because the cucumber impedance at high frequency becomes lesser than that of the potato at the same frequency range. Graphical Abstract: [Figure not available: see fulltext.] © 2016 The Visualization Society of Japan

  15. Developing high-frequency ultrasound tomography for testicular tumor imaging in rats: An in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chih-Chung, E-mail: cchuang@mail.ncku.edu.tw [Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (China); Chen, Wei-Tsen [Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City 24205, Taiwan (China)

    2014-01-15

    Purpose: This paper describes a feasibility study for developing a 35-MHz high-frequency ultrasound computed-tomography (HFUCT) system for imaging rat testicles. Methods: The performances of two kinds of HFUCT-attenuation and sound-speed UCT-based on transmission and pulse-echo modes were investigated in this study. Experiments were carried out using phantoms and actual rat testiclesin vitro. HFUCT images were reconstructed using a filtered backprojection algorithm. Results: The phantom experimental results indicated that all types of HFUCT can determine the dimensions of a plastic cylinder with a diameter of 500μm. Compared to sound-speed HFUCT, attenuation HFUCT exhibited a better performance in recognizing a tiny sclerosed region in a gelatin phantom. Therefore, the in vitro testicular experiments were performed using attenuation HFUCT based on transmission and pulse-echo modes. The experimentally measured attenuation coefficient and sound speed for healthy rat testicles were 2.92 ± 0.25 dB/mm and 1537 ± 25 m/s, respectively. Conclusions: A homogeneous texture was evident for healthy testicles using both modes. An artificial sclerosed tumor could also be clearly observed using two- and three-dimensional attenuation HFUCT in both modes. However, an object artifact was apparent in pulse-echo mode because of ultrasound beam refraction. All of the obtained experimental results indicate the potential of using HFUCT as a novel tool for monitoring the preclinical responses of testicular tumors in small animals.

  16. A comparative study of strain and shear-wave elastography in an elasticity phantom.

    Science.gov (United States)

    Carlsen, Jonathan F; Pedersen, Malene R; Ewertsen, Caroline; Săftoiu, Adrian; Lönn, Lars; Rafaelsen, Søren R; Nielsen, Michael B

    2015-03-01

    OBJECTIVE. The purpose of this study was to assess the diagnostic accuracy of strain and shear-wave elastography for determining targets of varying stiffness in a phantom. The effect of target diameter on elastographic assessments and the effect of depth on shear-wave velocity were also investigated. MATERIALS AND METHODS. We examined 20 targets of varying diameters (2.5-16.7 mm) and stiffnesses (8, 14, 45, and 80 kPa) with a 4-9-MHz linear-array transducer. Targets were evaluated 10 times with three different methods-shear-wave elastography, strain ratio, and strain histogram analysis-yielding 600 evaluations. AUCs were calculated for data divided between different stiffnesses. A 1.5-6-MHz curved-array transducer was used to assess the effect of depth (3.5 vs 6 cm) on shear-wave elastography in 80 scans. Mixed model analysis was performed to assess the effect of target diameter and depth. RESULTS. Strain ratio and strain histogram AUCs were higher than the shear-wave velocity AUC (p < 0.001) in data divided as 80 versus 45, 14, and 8 kPa. In data divided as 80 and 45 versus 14 and 8 kPa, the methods were equal (p = 0.959 and p = 1.000, respectively). Strain ratios were superior (p = 0.030), whereas strain histograms were not significantly better (p = 0.083) than shear-wave elastography in data divided as 80, 45, and 14 versus 8 kPa. Target diameter had an effect on all three methods (p = 0.001). Depth had an effect on shear-wave velocity (p = 0.001). CONCLUSION. The ability to discern different target stiffnesses varies between shear-wave and strain elastography. Target diameter affected all methods. Shear-wave elastography is affected by target depth.

  17. Image Quality in Oncologic Chest Computerized Tomography With Iterative Reconstruction: A Phantom Study.

    Science.gov (United States)

    Jensen, Kristin; Aaløkken, Trond Mogens; Tingberg, Anders; Fosse, Erik; Martinsen, Anne Catrine T

    2016-01-01

    The purpose of this study was to validate iterative reconstruction technique in oncologic chest computed tomography (CT). An anthropomorphic thorax phantom with 4 simulated tumors was scanned on a 64-slice CT scanner with 2 different iterative reconstruction techniques: one model based (MBIR) and one hybrid (ASiR). Dose levels of 14.9, 11.1, 6.7, and 0.6 mGy were used, and all images were reconstructed with filtered back projection (FBP) and both iterative reconstruction algorithms. Hounsfield units (HU) and absolute noise were measured in the tumors, lung, heart, diaphragm, and muscle. Contrast-to-noise ratios (CNRs) and signal-to-noise ratios (SNRs) were calculated. Model-based iterative reconstruction (MBIR) increased CNRs of the tumors (21.1-192.2) and SNRs in the lung (-49.0-165.6) and heart (3.1-8.5) at all dose levels compared with FBP (CNR, 1.1-23.0; SNR, -7.5-31.6 and 0.2-1.1) and with adaptive statistical iterative reconstruction (CNR, 1.2-33.2; SNR, -7.3-37.7 and 0.2-1.5). At the lowest dose level (0.6 mGy), MBIR reduced the cupping artifact (HU range: 17.0 HU compared with 31.4-32.2). An HU shift in the negative direction was seen with MBIR. Quantitative image quality parameters in oncologic chest CT are improved with MBIR compared with FBP and simpler iterative reconstruction algorithms. Artifacts at low doses are reduced. A shift in HU values was shown; thus, absolute HU values should be used with care.

  18. Treating Intractable Phantom Limb Pain with Ambulatory Continuous Peripheral Nerve Blocks: A Pilot Study

    Science.gov (United States)

    Ilfeld, Brian M.; Moeller-Bertram, Tobias; Hanling, Steven R.; Tokarz, Kyle; Mariano, Edward R.; Loland, Vanessa J.; Madison, Sarah J.; Ferguson, Eliza J.; Morgan, Anya C.; Wallace, Mark S.

    2013-01-01

    Background There is currently no reliable treatment for phantom limb pain (PLP). Chronic PLP and associated cortical abnormalities may be maintained from abnormal peripheral input, raising the possibility that a continuous peripheral nerve block (CPNB) of extended duration may permanently reorganize cortical pain mapping, thus providing lasting relief. Methods Three men with below-the-knee (2) or -elbow (1) amputations and intractable PLP received femoral/sciatic or infraclavicular perineural catheter(s), respectively. Subjects were randomized in a double-masked fashion to receive perineural ropivacaine (0.5%) or normal saline for over 6 days as outpatients using portable electronic infusion. Four months later, subjects returned for repeated perineural catheter insertion (“crossover”), and received an ambulatory infusion with the alternate solution. Subjects were followed for up to one year. Results By chance, all 3 subjects received saline during their initial infusion and reported little change in their PLP. One subject did not receive crossover treatment; but, the remaining 2 subjects reported complete resolution of their PLP during and immediately following treatment with ropivacaine. One subject experienced no PLP recurrence through the 52-week follow-up period; and, the other reported mild PLP occurring once each week of just a small fraction of his original pain (pre-treatment: continuous PLP rated 10/10; post-treatment: no PLP at baseline with average of 1 PLP episode each week rated 2/10) for 12 weeks (lost to follow-up thereafter). Conclusions A prolonged ambulatory CPNB may be a reliable treatment for intractable PLP. The results of this pilot study suggest that a large, randomized clinical trial is warranted. PMID:23489466

  19. Treating intractable phantom limb pain with ambulatory continuous peripheral nerve blocks: a pilot study.

    Science.gov (United States)

    Ilfeld, Brian M; Moeller-Bertram, Tobias; Hanling, Steven R; Tokarz, Kyle; Mariano, Edward R; Loland, Vanessa J; Madison, Sarah J; Ferguson, Eliza J; Morgan, Anya C; Wallace, Mark S

    2013-06-01

    There is currently no reliable treatment for phantom limb pain (PLP). Chronic PLP and associated cortical abnormalities may be maintained from abnormal peripheral input, raising the possibility that a continuous peripheral nerve block (CPNB) of extended duration may permanently reorganize cortical pain mapping, thus providing lasting relief. Three men with below-the-knee (2) or -elbow (1) amputations and intractable PLP received femoral/sciatic or infraclavicular perineural catheter(s), respectively. Subjects were randomized in a double-masked fashion to receive perineural ropivacaine (0.5%) or normal saline for over 6 days as outpatients using portable electronic infusion pumps. Four months later, subjects returned for repeated perineural catheter insertion and received an ambulatory infusion with the alternate solution ("crossover"). Subjects were followed for up to 1 year. By chance, all three subjects received saline during their initial infusion and reported little change in their PLP. One subject did not receive crossover treatment, but the remaining two subjects reported complete resolution of their PLP during and immediately following treatment with ropivacaine. One subject experienced no PLP recurrence through the 52-week follow-up period and the other reported mild PLP occurring once each week of just a small fraction of his original pain (pretreatment: continuous PLP rated 10/10; posttreatment: no PLP at baseline with average of one PLP episode each week rated 2/10) for 12 weeks (lost to follow-up thereafter). A prolonged ambulatory CPNB may be a reliable treatment for intractable PLP. The results of this pilot study suggest that a large, randomized clinical trial is warranted. Wiley Periodicals, Inc.

  20. Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Way, Ted W; Chan, H-P; Goodsitt, Mitchell M; Sahiner, Berkman; Hadjiiski, Lubomir M; Zhou Chuan; Chughtai, Aamer [Department of Radiology, University of Michigan, Ann Arbor, MI 48109 (United States)], E-mail: tway@umich.edu

    2008-03-07

    The purpose of this study is to investigate the effects of CT scanning and reconstruction parameters on automated segmentation and volumetric measurements of nodules in CT images. Phantom nodules of known sizes were used so that segmentation accuracy could be quantified in comparison to ground-truth volumes. Spherical nodules having 4.8, 9.5 and 16 mm diameters and 50 and 100 mg cc{sup -1} calcium contents were embedded in lung-tissue-simulating foam which was inserted in the thoracic cavity of a chest section phantom. CT scans of the phantom were acquired with a 16-slice scanner at various tube currents, pitches, fields-of-view and slice thicknesses. Scans were also taken using identical techniques either within the same day or five months apart for study of reproducibility. The phantom nodules were segmented with a three-dimensional active contour (3DAC) model that we previously developed for use on patient nodules. The percentage volume errors relative to the ground-truth volumes were estimated under the various imaging conditions. There was no statistically significant difference in volume error for repeated CT scans or scans taken with techniques where only pitch, field of view, or tube current (mA) were changed. However, the slice thickness significantly (p < 0.05) affected the volume error. Therefore, to evaluate nodule growth, consistent imaging conditions and high resolution should be used for acquisition of the serial CT scans, especially for smaller nodules. Understanding the effects of scanning and reconstruction parameters on volume measurements by 3DAC allows better interpretation of data and assessment of growth. Tracking nodule growth with computerized segmentation methods would reduce inter- and intraobserver variabilities.

  1. Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: a phantom study

    Science.gov (United States)

    Way, Ted W.; Chan, Heang-Ping; Goodsitt, Mitchell M.; Sahiner, Berkman; Hadjiiski, Lubomir M.; Zhou, Chuan; Chughtai, Aamer

    2008-03-01

    The purpose of this study is to investigate the effects of CT scanning and reconstruction parameters on automated segmentation and volumetric measurements of nodules in CT images. Phantom nodules of known sizes were used so that segmentation accuracy could be quantified in comparison to ground-truth volumes. Spherical nodules having 4.8, 9.5 and 16 mm diameters and 50 and 100 mg cc-1 calcium contents were embedded in lung-tissue-simulating foam which was inserted in the thoracic cavity of a chest section phantom. CT scans of the phantom were acquired with a 16-slice scanner at various tube currents, pitches, fields-of-view and slice thicknesses. Scans were also taken using identical techniques either within the same day or five months apart for study of reproducibility. The phantom nodules were segmented with a three-dimensional active contour (3DAC) model that we previously developed for use on patient nodules. The percentage volume errors relative to the ground-truth volumes were estimated under the various imaging conditions. There was no statistically significant difference in volume error for repeated CT scans or scans taken with techniques where only pitch, field of view, or tube current (mA) were changed. However, the slice thickness significantly (p < 0.05) affected the volume error. Therefore, to evaluate nodule growth, consistent imaging conditions and high resolution should be used for acquisition of the serial CT scans, especially for smaller nodules. Understanding the effects of scanning and reconstruction parameters on volume measurements by 3DAC allows better interpretation of data and assessment of growth. Tracking nodule growth with computerized segmentation methods would reduce inter- and intraobserver variabilities.

  2. Specification and estimation of sources of bias affecting neurological studies in PET/MR with an anatomical brain phantom

    Energy Technology Data Exchange (ETDEWEB)

    Teuho, J., E-mail: jarmo.teuho@tyks.fi [Turku PET Centre, Turku (Finland); Johansson, J. [Turku PET Centre, Turku (Finland); Linden, J. [Turku PET Centre, Turku (Finland); Department of Mathematics and Statistics, University of Turku, Turku (Finland); Saunavaara, V.; Tolvanen, T.; Teräs, M. [Turku PET Centre, Turku (Finland)

    2014-01-11

    Selection of reconstruction parameters has an effect on the image quantification in PET, with an additional contribution from a scanner-specific attenuation correction method. For achieving comparable results in inter- and intra-center comparisons, any existing quantitative differences should be identified and compensated for. In this study, a comparison between PET, PET/CT and PET/MR is performed by using an anatomical brain phantom, to identify and measure the amount of bias caused due to differences in reconstruction and attenuation correction methods especially in PET/MR. Differences were estimated by using visual, qualitative and quantitative analysis. The qualitative analysis consisted of a line profile analysis for measuring the reproduction of anatomical structures and the contribution of the amount of iterations to image contrast. The quantitative analysis consisted of measurement and comparison of 10 anatomical VOIs, where the HRRT was considered as the reference. All scanners reproduced the main anatomical structures of the phantom adequately, although the image contrast on the PET/MR was inferior when using a default clinical brain protocol. Image contrast was improved by increasing the amount of iterations from 2 to 5 while using 33 subsets. Furthermore, a PET/MR-specific bias was detected, which resulted in underestimation of the activity values in anatomical structures closest to the skull, due to the MR-derived attenuation map that ignores the bone. Thus, further improvements for the PET/MR reconstruction and attenuation correction could be achieved by optimization of RAMLA-specific reconstruction parameters and implementation of bone to the attenuation template. -- Highlights: • Comparison between PET, PET/CT and PET/MR was performed with a novel brain phantom. • The performance of reconstruction and attenuation correction in PET/MR was studied. • A recently developed brain phantom was found feasible for PET/MR imaging. • Contrast reduction

  3. Liquid tissue surrogates for X-ray and CT phantom studies.

    Science.gov (United States)

    FitzGerald, Paul F; Colborn, Robert E; Edic, Peter M; Lambert, Jack W; Bonitatibus, Peter J; Yeh, Benjamin M

    2017-10-07

    kVp were -104 HU (-113 HU) for adipose #3, -87 HU (-90 HU) for adipose #2, 59 HU (55 HU) for liver tissue, and 33 HU (31 HU) for pancreatic tissue; at 120 kVp, these were -83 HU (-83 HU) for adipose #3, -68 HU (-63 HU) for adipose #2, 55 HU (52 HU) for liver tissue, and 35 HU (33 HU) for pancreatic tissue. Our method for formulating tissue surrogates allowed straightforward production of solutions with CT attenuation that closely matched the target tissues' expected CT attenuation values and trends with kVp. The LTSs' inexpensive and widely available constituent chemicals, combined with their liquid state, should enable rapid production and versatile use among different phantom and experiment types. Further study is warranted, such as the inclusion of contrast agents. These liquid tissue surrogates may potentially accelerate development and testing of advanced CT imaging techniques and technologies. © 2017 American Association of Physicists in Medicine.

  4. Cherenkov excited phosphorescence-based pO2 estimation during multi-beam radiation therapy: phantom and simulation studies.

    Science.gov (United States)

    Holt, Robert W; Zhang, Rongxiao; Esipova, Tatiana V; Vinogradov, Sergei A; Glaser, Adam K; Gladstone, David J; Pogue, Brian W

    2014-09-21

    Megavoltage radiation beams used in External Beam Radiotherapy (EBRT) generate Cherenkov light emission in tissues and equivalent phantoms. This optical emission was utilized to excite an oxygen-sensitive phosphorescent probe, PtG4, which has been developed specifically for NIR lifetime-based sensing of the partial pressure of oxygen (pO2). Phosphorescence emission, at different time points with respect to the excitation pulse, was acquired by an intensifier-gated CCD camera synchronized with radiation pulses delivered by a medical linear accelerator. The pO2 distribution was tomographically recovered in a tissue-equivalent phantom during EBRT with multiple beams targeted from different angles at a tumor-like anomaly. The reconstructions were tested in two different phantoms that have fully oxygenated background, to compare a fully oxygenated and a fully deoxygenated inclusion. To simulate a realistic situation of EBRT, where the size and location of the tumor is well known, spatial information of a prescribed region was utilized in the recovery estimation. The phantom results show that region-averaged pO2 values were recovered successfully, differentiating aerated and deoxygenated inclusions. Finally, a simulation study was performed showing that pO2 in human brain tumors can be measured to within 15 mmHg for edge depths less than 10-20 mm using the Cherenkov Excited Phosphorescence Oxygen imaging (CEPhOx) method and PtG4 as a probe. This technique could allow non-invasive monitoring of pO2 in tumors during the normal process of EBRT, where beams are generally delivered from multiple angles or arcs during each treatment fraction.

  5. A head phantom study for intraocular dose evaluation of 64-slice multidetector CT examination in patients with suspected cranial trauma

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, Kosuke, E-mail: matsuk@mhs.mp.kanazawa-u.ac.jp [Department of Quantum Medical Technology, Faculty of Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942 (Japan); Koshida, Kichiro [Department of Quantum Medical Technology, Faculty of Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942 (Japan); Noto, Kimiya; Takata, Tadanori [Department of Radiological Technology, Kanazawa University Hospital, Kanazawa, Ishikawa (Japan); Suzuki, Masayuki [Department of Quantum Medical Technology, Faculty of Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942 (Japan); Shimono, Tetsunori [Department of Radiology, Hoshigaoka Koseinenkin Hospital, Hirakata, Osaka (Japan); Yamamoto, Tomoyuki [Department of Radiological Technology, Kanazawa University Hospital, Kanazawa, Ishikawa (Japan); Matsui, Osamu [Department of Radiology, Faculty of Medicine, Kanazawa University, Kanazawa, Ishikawa (Japan)

    2011-08-15

    Purpose: In cases of suspected cranial trauma, cranial CT examinations should be performed to rule out pathology. There are some methods available for reducing intraocular doses; however, it is difficult for the operators to conduct the necessary measurements because of restrictions in time and patient mobility, especially in high-energy trauma cases. Therefore, we performed a head phantom study for intraocular dose evaluation of 64-slice multidetector CT examination in patients with suspected cranial trauma. Materials and methods: Assuming that the orbitomeatal (OM) line and bed were vertical, a head phantom was tilted from 10 degrees caudally to 25 degrees cranially at 5-degree intervals. At each tilted position, the phantom was examined using a 64-section multidetector CT device using three acquisition protocols. Intraocular doses during each examination were measured using small dosimeters. Results: Assuming that the OM line and bed were vertical, intraocular doses varied between 52 and 140%, 17-138%, and 90-142% during helical, non-helical, and helical CT angiographic examinations, respectively. Intraocular doses increased when the phantom was tilted cranially. Conclusion: If possible, the best way to reduce the intraocular dose is by angling the gantry cranially, tilting the head of each patient caudally and adopting a non-helical acquisition method. During procedure, the acquisition angle should be angled cranially more than 0 degrees based on the OM line. The estimation of intraocular dose using the acquisition angle and displayed volumetric CT dose index might be useful to evaluate the deterministic effect risks and to inform patients about the associated risks.

  6. Does standoff material affect acoustic radiation force impulse elastography? A preclinical study of a modified elastography phantom.

    Science.gov (United States)

    Hollerieth, Katharina; Gaßmann, Bernhard; Wagenpfeil, Stefan; Kemmner, Stephan; Heemann, Uwe; Stock, Konrad Friedrich

    2017-07-28

    This study was conducted to determine the influence of standoff material on acoustic radiation force impulse (ARFI) measurements in an elasticity phantom by using two different probes. Using ARFI elastography, 10 observers measured the shear wave velocity (SWV, m/sec) in different lesions of an elasticity phantom with a convex 4C1 probe and a linear 9L4 probe. The experimental setup was expanded by the use of an interposed piece of porcine muscle as standoff material. The probe pressure on the phantom was registered. Faulty ARFI measurements occurred more often when quantifying the hardest lesion (74.0 kPa 4.97 m/sec) by the 9L4 probe with the porcine muscle as a standoff material interposed between the probe and the phantom. The success rate for ARFI measurements in these series was 52.4%, compared with 99.5% in the other series. The SWV values measured with the 9L4 probe were significantly higher (3.33±1.39 m/sec vs. 2.60±0.74 m/sec, Pmaterial were lower than those without the muscle (significant for 9L4, P=0.040). The deviation from the reference value and the variance increased significantly with the 9L4 probe if the muscle was in situ (B=0.27, P=0.004 and B=0.32, Pstudy, the pressure exerted by the operator had no effect on the SWV values. The presence of porcine muscle acting as a standoff material influenced the occurrence of failed measurements as well as the variance and the accuracy of the measured values. The linear high-frequency probe was particularly affected.

  7. Tmax Determined Using a Bayesian Estimation Deconvolution Algorithm Applied to Bolus Tracking Perfusion Imaging: A Digital Phantom Validation Study.

    Science.gov (United States)

    Uwano, Ikuko; Sasaki, Makoto; Kudo, Kohsuke; Boutelier, Timothé; Kameda, Hiroyuki; Mori, Futoshi; Yamashita, Fumio

    2017-01-10

    The Bayesian estimation algorithm improves the precision of bolus tracking perfusion imaging. However, this algorithm cannot directly calculate Tmax, the time scale widely used to identify ischemic penumbra, because Tmax is a non-physiological, artificial index that reflects the tracer arrival delay (TD) and other parameters. We calculated Tmax from the TD and mean transit time (MTT) obtained by the Bayesian algorithm and determined its accuracy in comparison with Tmax obtained by singular value decomposition (SVD) algorithms. The TD and MTT maps were generated by the Bayesian algorithm applied to digital phantoms with time-concentration curves that reflected a range of values for various perfusion metrics using a global arterial input function. Tmax was calculated from the TD and MTT using constants obtained by a linear least-squares fit to Tmax obtained from the two SVD algorithms that showed the best benchmarks in a previous study. Correlations between the Tmax values obtained by the Bayesian and SVD methods were examined. The Bayesian algorithm yielded accurate TD and MTT values relative to the true values of the digital phantom. Tmax calculated from the TD and MTT values with the least-squares fit constants showed excellent correlation (Pearson's correlation coefficient = 0.99) and agreement (intraclass correlation coefficient = 0.99) with Tmax obtained from SVD algorithms. Quantitative analyses of Tmax values calculated from Bayesian-estimation algorithm-derived TD and MTT from a digital phantom correlated and agreed well with Tmax values determined using SVD algorithms.

  8. Abdominal CT during pregnancy: a phantom study on the effect of patient centring on conceptus radiation dose and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Solomou, G.; Damilakis, J. [University of Crete, Faculty of Medicine, Department of Medical Physics, Heraklion, P.O. Box 2208, Crete (Greece); Papadakis, A.E. [University Hospital of Heraklion, Department of Medical Physics, Heraklion, P.O. Box 1352, Crete (Greece)

    2015-04-01

    To investigate the effect of patient centring on conceptus radiation dose and image quality in abdominal CT during pregnancy. Three anthropomorphic phantoms that represent a pregnant woman at the three trimesters of gestation were subjected to a routine abdominal CT. Examinations were performed with fixed mAs (mAs{sub f}) and with the automatic exposure control system (AEC) activated. The percent reduction between mAs{sub f} and modulated mAs (mAs{sub mod}) was calculated. Conceptus dose (D{sub c}) was measured using thermoluminescent dosimeters. To study the effect of misplacement of pregnant women on D{sub c}, each phantom was positioned at various locations relative to gantry isocentre. Image quality was evaluated on the basis of image noise, signal-to-noise ratio, and contrast-to-noise ratio. The maximum reduction between mAs{sub f} and mAs{sub mod} was 59.8 %, while the corresponding D{sub C} reduction was 59.3 %. D{sub C} was found to decrease by up to 25 % and 7.9 % for phantom locations below and above the isocentre, respectively. Image quality deteriorated when AEC was activated, and it was progressively improved from lower to higher than the isocentre locations. Centring errors do not result in an increase in D{sub c}. To maintain image quality, accurate centring is required. (orig.)

  9. Hollow agarose microneedle with silver coating for intradermal surface-enhanced Raman measurements: a skin-mimicking phantom study

    Science.gov (United States)

    Yuen, Clement; Liu, Quan

    2015-06-01

    Human intradermal components contain important clinical information beneficial to the field of immunology and disease diagnosis. Although microneedles have shown great potential to act as probes to break the human skin barrier for the minimally invasive measurement of intradermal components, metal microneedles that include stainless steel could cause the following problems: (1) sharp waste production, and (2) contamination due to reuse of microneedles especially in developing regions. In this study, we fabricate agarose microneedles coated with a layer of silver (Ag) and demonstrate their use as a probe for the realization of intradermal surface-enhanced Raman scattering measurements in a set of skin-mimicking phantoms. The Ag-coated agarose microneedle quantifies a range of glucose concentrations from 5 to 150 mM inside the skin phantoms with a root-mean-square error of 5.1 mM within 10 s. The needle is found enlarged by 53.9% after another 6 min inside the phantom. The shape-changing capability of this agarose microneedle ensures that the reuse of these microneedles is impossible, thus avoiding sharp waste production and preventing needle contamination, which shows the great potential for safe and effective needle-based measurements.

  10. Comparison of two co-registration methods for real-time ultrasonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C; Ellegaard, K; Boesen, Michael

    2010-01-01

    To test the accuracy of spatial registration of real-time ultrasonography (US) fused with MRI in a phantom.......To test the accuracy of spatial registration of real-time ultrasonography (US) fused with MRI in a phantom....

  11. Phantom limbs and neural plasticity.

    Science.gov (United States)

    Ramachandran, V S; Rogers-Ramachandran, D

    2000-03-01

    The study of phantom limbs has received tremendous impetus from recent studies linking changes in cortical topography with perceptual experience. Systematic psychophysical testing and functional imaging studies on patients with phantom limbs provide 2 unique opportunities. First, they allow us to demonstrate neural plasticity in the adult human brain. Second, by tracking perceptual changes (such as referred sensations) and changes in cortical topography in individual patients, we can begin to explore how the activity of sensory maps gives rise to conscious experience. Finally, phantom limbs also allow us to explore intersensory effects and the manner in which the brain constructs and updates a "body image" throughout life.

  12. Agency over a phantom limb and electromyographic activity on the stump depend on visuomotor synchrony: a case study.

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Kanayama, Noriaki; Kawamura, Mitsuru; Koyama, Shinichi

    2014-01-01

    Most patients, post-amputation, report the experience of a phantom limb. Some even sense voluntary movements when viewing a mirror image of the intact limb superimposed onto the phantom limb. While delayed visual feedback of an action is known to reduce a sense of agency, the effect of delayed visual feedback on phantom motor sensation (i.e., sense of controlling a phantom limb) has not been examined. Using a video-projection system, we examined the effect of delayed visual feedback on phantom motor sensation in an upper-limb amputee (male; left upper-limb amputation). He was instructed to view mirrored video images of his intact hand clasping and unclasping during a phantom limb movement. He then rated the intensity of the phantom motor sensation. Three types of hand movement images were presented as follows: synchronous, asynchronous with a 250-ms delay, and asynchronous with a 500-ms delay. Results showed that phantom motor sensation decreased when the image was delayed by 250 and 500 ms. However, when we instructed the patient to adjust the phase of phantom limb movement to that of the image with a 500-ms delay, phantom motor sensation increased. There was also a positive correlation between intensity of phantom motor sensation and electromyographic (EMG) activity on deltoids at the patient's stump. These results suggest that phantom motor sensation and EMG activity on the stump depend on visuomotor synchrony and top-down effects.

  13. Agency over a phantom limb and electromyographic activity on the stump depend on visuomotor synchrony: a case study

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Kanayama, Noriaki; Kawamura, Mitsuru; Koyama, Shinichi

    2014-01-01

    Most patients, post-amputation, report the experience of a phantom limb. Some even sense voluntary movements when viewing a mirror image of the intact limb superimposed onto the phantom limb. While delayed visual feedback of an action is known to reduce a sense of agency, the effect of delayed visual feedback on phantom motor sensation (i.e., sense of controlling a phantom limb) has not been examined. Using a video-projection system, we examined the effect of delayed visual feedback on phantom motor sensation in an upper-limb amputee (male; left upper-limb amputation). He was instructed to view mirrored video images of his intact hand clasping and unclasping during a phantom limb movement. He then rated the intensity of the phantom motor sensation. Three types of hand movement images were presented as follows: synchronous, asynchronous with a 250-ms delay, and asynchronous with a 500-ms delay. Results showed that phantom motor sensation decreased when the image was delayed by 250 and 500 ms. However, when we instructed the patient to adjust the phase of phantom limb movement to that of the image with a 500-ms delay, phantom motor sensation increased. There was also a positive correlation between intensity of phantom motor sensation and electromyographic (EMG) activity on deltoids at the patient’s stump. These results suggest that phantom motor sensation and EMG activity on the stump depend on visuomotor synchrony and top-down effects. PMID:25120449

  14. Agency over a phantom limb and electromyographic activity on the stump depend on visuomotor synchrony: a case study

    Directory of Open Access Journals (Sweden)

    Shu eImaizumi

    2014-07-01

    Full Text Available Most patients, post-amputation, report the experience of a phantom limb. Some even sense voluntary movements when viewing a mirror image of the intact limb superimposed onto the phantom limb. While delayed visual feedback of an action is known to reduce a sense of agency, the effect of delayed visual feedback on phantom motor sensation (i.e., sense of controlling a phantom limb has not been examined. Using a video-projection system, we examined the effect of delayed visual feedback on phantom motor sensation in an upper-limb amputee (male; left upper-limb amputation. He was instructed to view mirrored video images of his intact hand clasping and unclasping during a phantom limb movement. He then rated the intensity of the phantom motor sensation. Three types of hand movement images were presented as follows: synchronous, asynchronous with a 250-ms delay, and asynchronous with a 500-ms delay. Results showed that phantom motor sensation decreased when the image was delayed by 250 and 500 ms. However, when we instructed the patient to adjust the phase of phantom limb movement to that of the image with a 500-ms delay, phantom motor sensation increased. There was also a positive correlation between intensity of phantom motor sensation and electromyographic activity on deltoids at the patient’s stump. These results suggest that phantom motor sensation and electromyographic activity on the stump depend on visuomotor synchrony and top-down effects.

  15. Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

    Energy Technology Data Exchange (ETDEWEB)

    Gandhi, Diksha; Schmidt, Taly Gilat, E-mail: taly.gilat-schmidt@marquette.edu [Department of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin 53201 (United States); Crotty, Dominic J.; Stevens, Grant M. [GE Healthcare, Waukesha, Wisconsin 53188 (United States)

    2015-11-15

    Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head

  16. SU-F-J-174: A Series of Computational Human Phantoms in DICOM-RT Format for Normal Tissue Dose Reconstruction in Epidemiological Studies

    Energy Technology Data Exchange (ETDEWEB)

    Pyakuryal, A; Moroz, B [National Cancer Institute, National Institutes of Health, Rockville, MD (United States); Lee, C [University of Michigan, Ann Arbor, MI (United States); Pelletier, C; Jung, J [East Carolina University Greenville, NC (United States); Lee, C [National Cancer Institute, Rockville, MD (United States)

    2016-06-15

    Purpose: Epidemiological studies of second cancer risk in radiotherapy patients often require individualized dose estimates of normal tissues. Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D radiological images or not even available. Generic patient CT images are often used in commercial radiotherapy treatment planning system (TPS) to reconstruct normal tissue doses. The objective of the current work was to develop a series of reference size computational human phantoms in DICOM-RT format for direct use in dose reconstruction in TPS. Methods: Contours of 93 organs and tissues were extracted from a series of pediatric and adult hybrid computational human phantoms (newborn, 1-, 5-, 10-, 15-year-old, and adult males and females) using Rhinoceros software. A MATLAB script was created to convert the contours into the DICOM-RT structure format. The simulated CT images with the resolution of 1×1×3 mm3 were also generated from the binary phantom format and coupled with the DICOM-structure files. Accurate volumes of the organs were drawn in the format using precise delineation of the contours in converted format. Due to complex geometry of organs, higher resolution (1×1×1 mm3) was found to be more efficient in the conversion of newborn and 1-year-old phantoms. Results: Contour sets were efficiently converted into DICOM-RT structures in relatively short time (about 30 minutes for each phantom). A good agreement was observed in the volumes between the original phantoms and the converted contours for large organs (NRMSD<1.0%) and small organs (NRMSD<7.7%). Conclusion: A comprehensive series of computational human phantoms in DICOM-RT format was created to support epidemiological studies of second cancer risks in radiotherapy patients. We confirmed the DICOM-RT phantoms were successfully imported into the TPS programs of major vendors.

  17. Phantom studies of triple photon absorptiometry and bone mineral measurement at a hip prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Farrell, T.J.; Webber, C.E. (Chedoke McMaster Hospitals, Hamilton, ON (Canada). Dept. of Nuclear Medicine)

    1992-03-01

    The feasibility of using triple photon absorptiometry (TPA) for the measurement of bone mineral mass about a hip prosthesis was examined. A theoretical expression describing the variance of TPA measurements was verified using a triple photon source and phantom materials which simulate the soft tissue-bone mineral-metal prosthesis system. The expression for the variance was used to determine an optimized set of photon energies. It was shown that a precision of 3% could be obtained for reasonable measurement times using this optimized set of energies and that TPA should be a feasible approach for measurement of bone mineral about a hip prosthesis. (orig.).

  18. Acupuncture for the treatment of phantom limb pain in lower limb amputees: study protocol for a randomized controlled feasibility trial.

    Science.gov (United States)

    Trevelyan, Esmé G; Turner, Warren A; Robinson, Nicola

    2015-04-12

    Phantom limb pain is a prevalent condition that is difficult to manage, with a lack of robust evidence to support the use of many adjunctive treatments. Acupuncture can be effective in the management of many painful conditions but little is known about its effectiveness in treating phantom limb pain. The aim of this study is to explore the feasibility of conducting a randomized controlled trial comparing acupuncture and routine care in a group of lower limb amputees with phantom limb pain. An unstratified, pragmatic, randomized, two-armed, controlled trial of parallel design comparing acupuncture and usual care control will be conducted. A total of 20 participants will be randomly assigned to receive either usual care or usual care plus acupuncture. Acupuncture will include eight 1 hour treatments delivered pragmatically over 4 weeks by practitioners trained in traditional Chinese medicine. As outcome measures, the Numerical Pain Rating Scale, short-form McGill Pain Questionnaire 2, EQ-5D-5 L, Hospital Anxiety and Depression Scale, 10-Item Perceived Stress Scale, Insomnia Severity Index, and Patient Global Impression of Change will be completed at baseline, weekly for the duration of the study and at 1 month after completion of the study. After completion of the trial, participants will provide feedback though semi-structured interviews. Feasibility will be determined through the ability to recruit to the study, success of the randomization process, completion of acupuncture intervention, acceptability of random allocation and completion of outcome measures. Acceptability of the acupuncture intervention will be determined through semi-structured interviews with participants. The appropriateness of outcome measures for a future trial will be addressed through completion rates of questionnaires and participant feedback. Data generated on effect size will be used for future sample size calculations and will inform the development of an appropriate and feasible

  19. Quantitative assessment of soft tissue deformation using digital speckle pattern interferometry: studies on phantom breast models.

    Science.gov (United States)

    Karuppanan, Udayakumar; Unni, Sujatha Narayanan; Angarai, Ganesan R

    2017-01-01

    Assessment of mechanical properties of soft matter is a challenging task in a purely noninvasive and noncontact environment. As tissue mechanical properties play a vital role in determining tissue health status, such noninvasive methods offer great potential in framing large-scale medical screening strategies. The digital speckle pattern interferometry (DSPI)-based image capture and analysis system described here is capable of extracting the deformation information from a single acquired fringe pattern. Such a method of analysis would be required in the case of the highly dynamic nature of speckle patterns derived from soft tissues while applying mechanical compression. Soft phantoms mimicking breast tissue optical and mechanical properties were fabricated and tested in the DSPI out of plane configuration set up. Hilbert transform (HT)-based image analysis algorithm was developed to extract the phase and corresponding deformation of the sample from a single acquired fringe pattern. The experimental fringe contours were found to correlate with numerically simulated deformation patterns of the sample using Abaqus finite element analysis software. The extracted deformation from the experimental fringe pattern using the HT-based algorithm is compared with the deformation value obtained using numerical simulation under similar conditions of loading and the results are found to correlate with an average %error of 10. The proposed method is applied on breast phantoms fabricated with included subsurface anomaly mimicking cancerous tissue and the results are analyzed.

  20. Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study

    Science.gov (United States)

    Doo, K W; Yong, H S; Woo, O H; Lee, K Y; Oh, Y-W

    2014-01-01

    Objective: The purpose of this study was to assess accuracy of lung nodule volumetry in low-dose CT with application of iterative reconstruction (IR) according to nodule size, nodule density and CT tube currents, using artificial lung nodules within an anthropomorphic thoracic phantom. Methods: Eight artificial nodules (four diameters: 5, 8, 10 and 12 mm; two CT densities: −630 HU that represents ground-glass nodule and +100 HU that represents solid nodule) were randomly placed inside a thoracic phantom. Scans were performed with tube current–time product to 10, 20, 30 and 50 mAs. Images were reconstructed with IR and filtered back projection (FBP). We compared volume estimates to a reference standard and calculated the absolute percentage error (APE). Results: The APE of all nodules was significantly lower when IR was used than with FBP (7.5 ± 4.7% compared with 9.0 ±6.9%; p CT tube current. Conclusion: Lung nodule volumetry in low-dose CT by application of IR showed reliable accuracy in a phantom study. Lung nodule volumetry can be reliably applicable to all lung nodules including small, ground-glass nodules even in ultra-low-dose CT with application of IR. Advances in knowledge: IR significantly improved the accuracy of lung nodule volumetry compared with FBP particularly for ground-glass (−630 HU) nodules. Volumetry in low-dose CT can be utilized in patient with lung nodule work-up, and IR has benefit for small, ground-glass lung nodules in low-dose CT. PMID:25026866

  1. A multivendor phantom study comparing the image quality produced from three state-of-the-art SPECT-CT systems.

    Science.gov (United States)

    Hughes, Tyler; Celler, Anna

    2012-06-01

    Ongoing advancements in single photon emission computed tomography with on-board X-ray computed tomography (SPECT-CT) hardware and software raise important questions regarding the relative performances of various cameras and their respective image-processing software. This phantom-based study compares images produced from three state-of-the-art cameras using four image quality measurements. A thorax phantom modeling the spine, lungs, a healthy heart, and three tumors (cylindrical bottles) was scanned using the following SPECT-CT systems: Philips' Precedence (PP), GE's Infinia-Hawkeye (GH), and Siemens' Symbia-T6 (SS). For each scan, Tc-99m solutions were injected into the heart, three bottles, and thorax to yield activity concentration ratios of roughly 6:1 for both heart:thorax and tumor:thorax. The data were reconstructed using the most advanced software available on the cameras, namely, Evolution for Bone and Evolution for Cardiac (EVB and EVC, respectively), Astonish (AST), and Flash3D (FLA) for GH, PP, and SS, respectively. In addition, all sets of data were reconstructed using our in-house software. The mean values of activity error, uniformity, signal-to-noise ratio, and contrast error were used as figures of merit (FOM). No significant differences were observed for all FOM between all in-house reconstructions using PP, GH, and SS acquisition data. The mean activity error for the AST reconstruction (-24.0±1.6%) was significantly closer to the truth relative to EVB (-38.0±1.6%), EVC (-34.5±2.3%), and FLA (-33.8±1.6%). No significant differences were found between EVC and FLA for all FOM. In this phantom-based study, Philips' AST provided the most quantitatively accurate and highest contrast images, whereas Siemens' FLA and GE's EVC provided relatively higher signal-to-noise ratios and more uniform images.

  2. A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

    Directory of Open Access Journals (Sweden)

    Payam Samadi Miandoab

    2016-12-01

    Full Text Available Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion of dynamic organs, a phantom employs non-uniform rational B-splines (NURBS-based Cardiac-Torso method with spline-based model to generate 4D computed tomography (CT images. First, to generate all the possible roto-translation positions, the 4D CT images were imported to Medical Image Data Examiner (AMIDE. Then, for automatic, real time verification of geometrical setup, an artificial neural network (ANN was proposed to estimate patient displacement, using training sets. Moreover, three external motion markers were synchronized with a patient couch position as reference points. In addition, the technique was validated through simulated activities by using reference 4D CT data acquired from five patients. Results The results indicated that patient geometrical set-up is highly depended on the comprehensiveness of training set. By using ANN model, the average patient setup error in XCAT phantom was reduced from 17.26 mm to 0.50 mm. In addition, in the five real patients, these average errors were decreased from 18.26 mm to 1.48 mm various breathing phases ranging from inhalation to exhalation were taken into account for patient setup. Uncertainty error assessment and different setup errors were obtained from each respiration phase. Conclusion This study proposed a new method for alignment of patient setup error using ANN model. Additionally, our correlation model (ANN could estimate true patient position with less error.

  3. Revisiting optical clearing with dimethyl sulfoxide (DMSO): in vitro and in vivo studies

    Science.gov (United States)

    McClure, R. Anthony; Stoianovici, Charles; Karma, Sanjeev; Choi, Bernard

    2009-02-01

    Functional optical characterization of disease progression and response to therapy suffers from loss of spatial resolution and imaging depth due to scattering, impacting the ability of researchers to localize and quantify molecular processes. Here we report on the ability of dimethyl sulfoxide (DMSO) to reduce temporarily the optical scattering of skin. Data collected from in vitro phantom images and in vivo fluorescence images demonstrate the potential of this simple method to mitigate the blurring effects of scattering with topical application, which we expect will improve the accuracy and localization of in vivo molecular imaging studies.

  4. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  5. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study

    Science.gov (United States)

    Grosser, Oliver S.; Kupitz, Dennis; Ruf, Juri; Czuczwara, Damian; Steffen, Ingo G.; Furth, Christian; Thormann, Markus; Loewenthal, David; Ricke, Jens; Amthauer, Holger

    2015-01-01

    Background Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR) on the image quality of the low-dose CT images. Methodology/Principal Findings Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU) values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88) and the contrast-to-noise ratio (CNR) was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04). In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001). Conclusion/Significance In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality. PMID:26390216

  6. Influence of dose reduction and iterative reconstruction on CT calcium scores: a multi-manufacturer dynamic phantom study.

    Science.gov (United States)

    van der Werf, N R; Willemink, M J; Willems, T P; Greuter, M J W; Leiner, T

    2017-06-01

    To evaluate the influence of dose reduction in combination with iterative reconstruction (IR) on coronary calcium scores (CCS) in a dynamic phantom on state-of-the-art CT systems from different manufacturers. Calcified inserts in an anthropomorphic chest phantom were translated at 20 mm/s corresponding to heart rates between 60 and 75 bpm. The inserts were scanned five times with routinely used CCS protocols at reference dose and 40 and 80% dose reduction on four high-end CT systems. Filtered back projection (FBP) and increasing levels of IR were applied. Noise levels were determined. CCS, quantified as Agatston and mass scores, were compared to physical mass and scores at FBP reference dose. For the reference dose in combination with FBP, noise level variation between CT systems was less than 18%. Decreasing dose almost always resulted in increased CCS, while at increased levels of IR, CCS decreased again. The influence of IR on CCS was smaller than the influence of dose reduction. At reference dose, physical mass was underestimated 3-30%. All CT systems showed similar CCS at 40% dose reduction in combinations with specific reconstructions. For some CT systems CCS was not affected at 80% dose reduction, in combination with IR. This multivendor study showed that radiation dose reductions of 40% did not influence CCS in a dynamic phantom using state-of-the-art CT systems in combination with specific reconstruction settings. Dose reduction resulted in increased noise and consequently increased CCS, whereas increased IR resulted in decreased CCS.

  7. CT image quality in sinogram affirmed iterative reconstruction phantom study - is there a point of diminishing returns?

    Energy Technology Data Exchange (ETDEWEB)

    Infante, Juan C. [University of Miami, Department of Radiology, Miami, FL (United States); Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Liu, Yu [Medical College of Wisconsin, Department of Radiology, Milwaukee, WI (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States)

    2017-03-15

    In our pediatric practice, we have observed qualitatively limited improvement in the image quality of images generated with sinogram affirmed iterative reconstruction (SAFIRE) compared to series generated with filtered back projection (FBP), particularly in cases near or below a CT dose index volume (CTDI{sub vol}) of 1-mGy. To determine whether the image quality advantage of SAFIRE remains constant across clinically used CT dose levels in an American College of Radiology (ACR) CT accreditation phantom including the lower dose range used in pediatric imaging. An exemption from institutional review board approval was obtained for this phantom-based study. An ACR quality phantom was scanned in incremental kV steps and effective tube current intervals. Acquisitions were reconstructed with FBP and SAFIRE strengths of 1, 3 and 5. Image quality measures were calculated including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), low-contrast resolution and high-contrast resolution. Peak SNR was also calculated. Descriptive and nonparametric statistics were used to compare these image quality metrics while normalizing to CT dose index (CTDI). The percent improvement in SNR and peak SNR of SAFIRE reconstructions compared to FBP decreased from about 70% for image sets acquired above a 1.42 mGy CTDI to 25% at a 0.25 mGy CTDI. CNR improvement with SAFIRE did not vary with dose. No significant difference was seen in the low-contrast resolution or high-contrast resolution of SAFIRE images compared to FBP. SNR did not improve equally after applying SAFIRE across a spectrum clinically used CTDIs. Below a threshold CTDI, the incremental improvement of SAFIRE compared to FBP decreased. (orig.)

  8. Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiaowei; Servaes, Sabah; Darge, Kassa [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); University of Pennsylvania, The Perelman School of Medicine, Philadelphia, PA (United States); McCullough, William P. [University of Virginia Health System, Department of Radiology and Medical Imaging, Charlottesville, VA (United States); Mecca, Patricia [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2016-11-15

    Dual-energy CT technology is available on scanners from several vendors and offers significant advantages over classic single-energy CT technology in multiple clinical applications. Many studies have detailed dual-energy CT applications in adults and several have evaluated the relative radiation dose performance of dual-energy CT in adult imaging. However, little has been published on dual-energy CT imaging in the pediatric population, and the relative dose performance of dual-energy CT imaging in the pediatric population is not well described. When evaluating dual-energy CT technology for implementation into a routine clinical pediatric imaging practice, the radiation dose implications must be considered, and when comparing relative CT dose performance, image quality must also be evaluated. Therefore the purpose of this study is to develop dual-energy CT scan protocols based on our optimized single-energy scan protocols and compare the dose. We scanned the head, chest and abdomen regions of pediatric-size anthropomorphic phantoms with contrast inserts, using our optimized single-energy clinical imaging protocols on a Siemens Flash {sup registered} CT scanner. We then scanned the phantoms in dual-energy mode using matching image-quality reference settings. The effective CT dose index volume (CTDI{sub vol}) of the scans was used as a surrogate for relative dose in comparing the single- and dual-energy scans. Additionally, we evaluated image quality using visual assessment and contrast-to-noise ratio. Dual-energy CT scans of the head and abdomen were dose-neutral for all three phantoms. Dual-energy CT scans of the chest showed a relative dose increase over the single-energy scan for 1- and 5-year-old child-based age-equivalent phantoms, ranging 11-20%. Quantitative analysis of image quality showed no statistically significant difference in image quality between the single-energy and dual-energy scans. There was no clinically significant difference in image quality by

  9. Characterization of a new ultrasound device designed for measuring cortical porosity at the human tibia: A phantom study.

    Science.gov (United States)

    Gräsel, M; Glüer, C-C; Barkmann, R

    2017-04-01

    Quantitative ultrasound (QUS) measurements of trabecular bone are a useful tool for the assessment of osteoporotic fracture risk. However, cortical bone properties (e.g. porosity) have an impact on bone strength as well and thus current research is focused on QUS assessment of cortical bone properties. Simulation studies of ultrasound propagation through cortical bone indicate that anisotropy, calculated from the ratio of the velocities in axial and tangential directions, is correlated with porosity. However, this relationship is affected by error sources, specifically bone surface curvature and variability of probe positioning. With the aim of in vivo estimation of cortical porosity a new ultrasound device was developed, which sequentially measures velocities in 3 different directions (axial=0° and ±37.5°) using the axial transmission method. Measurements on planar porosity phantoms (0-25%) were performed to confirm the results of the afore mentioned simulation studies. Additionally, measurements on cylindrical phantoms without pores (min. radius=34mm for strongest curvature) were performed to estimate the influence of surface curvature on velocity measurements (the tibia bone surface is fairly flat but may show surface curvature in some patients). The velocities in the axial and ±37.5° directions were used to calculate an anisotropy index. The velocities measured on the porosity phantoms showed a decrease by -6.3±0.2m/s and -10.1±0.2m/s per percent increase in porosity in axial and ±37.5° directions, respectively. Surface curvature had an effect on the velocities measured in ±37.5° directions which could be minimized by a correction algorithm resulting in an error of 5m/s. The anisotropy index could be used to estimate porosity with an accuracy error of 1.5%. These results indicate that an estimation of porosity using velocity measurements in different directions might be feasible, even in bones with curved surface. These results obtained on phantom

  10. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J. [Institut Curie, Imaging Department, Paris (France); Pavia, Y.; Pierrat, N. [Institut Curie, Medical Physics Department, Paris (France)

    2014-01-15

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  11. Phantom pain in bilateral upper limb amputation.

    Science.gov (United States)

    Modirian, Ehsan; Shojaei, Hadi; Soroush, Mohammad Reza; Masoumi, Mahdi

    2009-01-01

    To alert health professionals on presence and extent of phantom pain and sensation following bilateral upper limb amputation. Of a total of 140 war-related bilateral upper limb amputees in Iran, 103 subjects were thoroughly examined in this cross-sectional study by a physical medicine specialist. The patients were questioned for the presence of phantom pain and sensations, and frequency and intensity of the feeling were recorded. At 17.1 +/- 6.1 years after injury, 82.0% of the 103 amputees suffered from phantom sensation, including varying degrees of phantom limb pain in 53.9% of stumps. Phantom phenomena had a higher frequency in the right extremities, but this was not statistically significant (p > 0.01). Of those amputees who had phantom pain or sensation, 51.2% reported that they 'always' had phantom limb sensation; and approximately one-fourth of the subjects (24.6%) 'always' had phantom pain. Among the stumps who reported phantom pain (N=112), the pain was excruciating (38.5%), distressing (34.9%) or discomforting (25.6%). A significant statistical relation between phantom limb sensation and level of amputation was observed (p phantom pain; medical and surgical modalities only bring temporary relief, and less than 1% of the respondents achieve permanent relief through different treatment methods.

  12. Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose

    Science.gov (United States)

    Ding, Aiping; Mille, Matthew M.; Liu, Tianyu; Caracappa, Peter F.; Xu, X. George

    2012-05-01

    Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newly developed phantoms representing overweight and obese patients. These phantoms were derived from the previously developed RPI-adult male and female computational phantoms. The result was a set of ten phantoms (five males, five females) with body mass indexes ranging from 23.5 (normal body weight) to 46.4 kg m-2 (morbidly obese). The phantoms were modeled using triangular mesh geometry and include specified amounts of the subcutaneous adipose tissue and visceral adipose tissue. The mesh-based phantoms were then voxelized and defined in the Monte Carlo N-Particle Extended code to calculate organ doses from CT imaging. Chest-abdomen-pelvis scanning protocols for a GE LightSpeed 16 scanner operating at 120 and 140 kVp were considered. It was found that for the same scanner operating parameters, radiation doses to organs deep in the abdomen (e.g., colon) can be up to 59% smaller for obese individuals compared to those of normal body weight. This effect was found to be less significant for shallow organs. On the other hand, increasing the tube potential from 120 to 140 kVp for the same obese individual resulted in increased organ doses by as much as 56% for organs within the scan field (e.g., stomach) and 62% for those out of the scan field (e.g., thyroid), respectively. As higher tube currents are often used for larger patients to maintain image quality, it was of interest to quantify the associated effective dose. It was found from this study that when the mAs was doubled for the obese level-I, obese level-II and morbidly-obese phantoms, the effective dose relative to that of the normal weight phantom increased by 57%, 42% and 23%, respectively. This set

  13. Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose.

    Science.gov (United States)

    Ding, Aiping; Mille, Matthew M; Liu, Tianyu; Caracappa, Peter F; Xu, X George

    2012-05-07

    Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newly developed phantoms representing overweight and obese patients. These phantoms were derived from the previously developed RPI-adult male and female computational phantoms. The result was a set of ten phantoms (five males, five females) with body mass indexes ranging from 23.5 (normal body weight) to 46.4 kg m(-2) (morbidly obese). The phantoms were modeled using triangular mesh geometry and include specified amounts of the subcutaneous adipose tissue and visceral adipose tissue. The mesh-based phantoms were then voxelized and defined in the Monte Carlo N-Particle Extended code to calculate organ doses from CT imaging. Chest-abdomen-pelvis scanning protocols for a GE LightSpeed 16 scanner operating at 120 and 140 kVp were considered. It was found that for the same scanner operating parameters, radiation doses to organs deep in the abdomen (e.g., colon) can be up to 59% smaller for obese individuals compared to those of normal body weight. This effect was found to be less significant for shallow organs. On the other hand, increasing the tube potential from 120 to 140 kVp for the same obese individual resulted in increased organ doses by as much as 56% for organs within the scan field (e.g., stomach) and 62% for those out of the scan field (e.g., thyroid), respectively. As higher tube currents are often used for larger patients to maintain image quality, it was of interest to quantify the associated effective dose. It was found from this study that when the mAs was doubled for the obese level-I, obese level-II and morbidly-obese phantoms, the effective dose relative to that of the normal weight phantom increased by 57%, 42% and 23%, respectively. This

  14. Towards assessing cortical bone porosity using low-frequency quantitative acoustics: A phantom-based study.

    Directory of Open Access Journals (Sweden)

    Florian Vogl

    Full Text Available Cortical porosity is a key characteristic governing the structural properties and mechanical behaviour of bone, and its quantification is therefore critical for understanding and monitoring the development of various bone pathologies such as osteoporosis. Axial transmission quantitative acoustics has shown to be a promising technique for assessing bone health in a fast, non-invasive, and radiation-free manner. One major hurdle in bringing this approach to clinical application is the entanglement of the effects of individual characteristics (e.g. geometry, porosity, anisotropy etc. on the measured wave propagation. In order to address this entanglement problem, we therefore propose a systematic bottom-up approach, in which only one bone property is varied, before addressing interaction effects. This work therefore investigated the sensitivity of low-frequency quantitative acoustics to changes in porosity as well as individual pore characteristics using specifically designed cortical bone phantoms.14 bone phantoms were designed with varying pore size, axial-, and radial pore number, resulting in porosities (bone volume fraction between 0% and 15%, similar to porosity values found in human cortical bone. All phantoms were manufactured using laser sintering, measured using axial-transmission acoustics and analysed using a full-wave approach. Experimental results were compared to theoretical predictions based on a modified Timoshenko theory.A clear dependence of phase velocity on frequency and porosity produced by increasing pore size or radial pore number was demonstrated, with the velocity decreasing by between 2-5 m/s per percent of additional porosity, which corresponds to -0.5% to -1.0% of wave speed. While the change in phase velocity due to axial pore number was consistent with the results due to pore size and radial pore number, the relative uncertainties for the estimates were too high to draw any conclusions for this parameter.This work has

  15. Towards assessing cortical bone porosity using low-frequency quantitative acoustics: A phantom-based study.

    Science.gov (United States)

    Vogl, Florian; Bernet, Benjamin; Bolognesi, Daniele; Taylor, William R

    2017-01-01

    Cortical porosity is a key characteristic governing the structural properties and mechanical behaviour of bone, and its quantification is therefore critical for understanding and monitoring the development of various bone pathologies such as osteoporosis. Axial transmission quantitative acoustics has shown to be a promising technique for assessing bone health in a fast, non-invasive, and radiation-free manner. One major hurdle in bringing this approach to clinical application is the entanglement of the effects of individual characteristics (e.g. geometry, porosity, anisotropy etc.) on the measured wave propagation. In order to address this entanglement problem, we therefore propose a systematic bottom-up approach, in which only one bone property is varied, before addressing interaction effects. This work therefore investigated the sensitivity of low-frequency quantitative acoustics to changes in porosity as well as individual pore characteristics using specifically designed cortical bone phantoms. 14 bone phantoms were designed with varying pore size, axial-, and radial pore number, resulting in porosities (bone volume fraction) between 0% and 15%, similar to porosity values found in human cortical bone. All phantoms were manufactured using laser sintering, measured using axial-transmission acoustics and analysed using a full-wave approach. Experimental results were compared to theoretical predictions based on a modified Timoshenko theory. A clear dependence of phase velocity on frequency and porosity produced by increasing pore size or radial pore number was demonstrated, with the velocity decreasing by between 2-5 m/s per percent of additional porosity, which corresponds to -0.5% to -1.0% of wave speed. While the change in phase velocity due to axial pore number was consistent with the results due to pore size and radial pore number, the relative uncertainties for the estimates were too high to draw any conclusions for this parameter. This work has shown the

  16. Evaluation of biexponential relaxation processes by magnetic resonance imaging. A phantom study

    DEFF Research Database (Denmark)

    Kjaer, L; Thomsen, C; Larsson, H B

    1988-01-01

    .5 tesla (T). Measurements were performed on a phantom of bicompartmental perspex boxes with combinations of different CuSO4 concentrations. T1 determination was based on a 12-points partial saturation inversion recovery pulse sequence. T2 determination was provided by a multiple spin echo sequence with 32...... echoes. Applying biexponential curve analysis, a significant deviation from a monoexponential behaviour was recognized at a ratio of corresponding relaxation rates of about 3 and 2, estimating T1 and T2 relaxation, respectively (p less than 0.01, F-test). Requiring an SD less than or equal to 10 per cent...... for each set of parameters, the biexponential model was accepted when this ratio exceeded a factor of 5 and 8, respectively. Referring to 'expected' T1 and T2 values, however, an accuracy within 20 per cent only was observed at ratios of at least 6 and 15. It is concluded that quantitative estimation...

  17. 3D Surface Realignment Tracking for Medical Imaging: A Phantom Study with PET Motion Correction

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Paulsen, Rasmus Reinhold; Jensen, Rasmus Ramsbøl

    2011-01-01

    is equipped with a near infrared diode and uses phase-shift interferometry to compute 3D representations of the forehead of the patient. These 3D point clouds are progressively aligned to a reference surface and thereby giving the head pose changes. The estimated pose changes are used to reposition a sequence...... of recon- structed PET frames. To align the structured light system with the PET coordinate system a novel registration algorithm based on the PET trans- mission scan and an initial surface has been developed. The performance of the complete setup has been evaluated using a custom made phantom based...... on a plastic mannequin head equipped with two positron emitting line sources. Two experiments were performed. The rst simulates rapid and short head movements, while the second simulates slow and contin- uous movements. In both cases, the system was able to produce PET scans with focus the PET reconstructions...

  18. Radiation exposure during chest X-ray examinations in a premature intensive care unit: phantom studies

    Energy Technology Data Exchange (ETDEWEB)

    Duetting, T.; Foerste, B.; Darge, K.; Troeger, J. [Heidelberg Univ. (Germany). Dept. of Paediatric Radiology; Knoch, T. [Heidelberg Univ. (Germany). Central Radiation Protection

    1999-03-01

    Background. There are few reports on the radiation dose received by infants, their family and radiographers exposed to scatter radiation in a premature baby intensive care unit. Objective. To evaluate the degree of radiation exposure from diagnostic X-ray examinations with mobile X-ray machines in a premature intensive care unit. Materials and methods. The radiation exposure of an adjacent newborn, the radiographer and other persons in the room was simulated using phantoms during X-ray examination of the chest using vertical and horizontal beams. Results. Most of the measured doses were below the registration limit of the measuring apparatus and had to be extrapolated by multiple exposures. Without exception, the maximal doses were significantly lower than the permitted limit for persons not professionally exposed to X-rays. Conclusions. Recommendations to avoid unnecessary radiation exposure are given. (orig.) With 2 figs., 3 tabs., 10 refs.

  19. Photoacoustic imaging with planoconcave optical microresonator sensors: feasibility studies based on phantom imaging

    Science.gov (United States)

    Guggenheim, James A.; Zhang, Edward Z.; Beard, Paul C.

    2017-03-01

    The planar Fabry-Pérot (FP) sensor provides high quality photoacoustic (PA) images but beam walk-off limits sensitivity and thus penetration depth to ≍1 cm. Planoconcave microresonator sensors eliminate beam walk-off enabling sensitivity to be increased by an order-of-magnitude whilst retaining the highly favourable frequency response and directional characteristics of the FP sensor. The first tomographic PA images obtained in a tissue-realistic phantom using the new sensors are described. These show that the microresonator sensors provide near identical image quality as the planar FP sensor but with significantly greater penetration depth (e.g. 2-3cm) due to their higher sensitivity. This offers the prospect of whole body small animal imaging and clinical imaging to depths previously unattainable using the FP planar sensor.

  20. A two-step optical flow method for strain estimation in elastography: Simulation and phantom study.

    Science.gov (United States)

    Pan, Xiaochang; Gao, Jing; Tao, Shengzhen; Liu, Ke; Bai, Jing; Luo, Jianwen

    2014-04-01

    Optical flow (OF) method has been used in ultrasound elastography to estimate the strain distribution in tissues. However the bias of strain estimation by OF has previously been shown to be close to 20%. The objective in this paper is to improve the performance of OF-based strain estimation, a two-step OF method with a local warping technique is proposed in this paper. The local warping technique effectively decreases the decorrelation of the signals, and hence improves the performance of strain estimation. Simulations on both homogeneous and heterogeneous models with different strains are performed. Experiments on a heterogeneous tissue-mimicking phantom are also carried out. Simulation results of the homogeneous model show that the two-step OF method reduces the bias of strain estimation from 23.77% to 1.65%, and reduces the standard deviation of strain estimation from 2.9×10(-3) to 0.47×10(-3). Simulation results of the heterogeneous model shows that the signals-to-noise ratio (SNRe) of strain estimation is improved by 2.1 and 5.3dB in the inclusion and background, respectively, and the contrast-to-noise ratio (CNRe) is improved by 6.8dB. Finally, results of phantom experiments show that, by using the proposed method, the SNRe is increased by 4.0dB and 8.9dB in the inclusion and background, respectively, while the CNRe is increased by 13.1dB. The proposed two-step OF method is thus demonstrated capable of improving the performance of strain estimation in OF-based elastography. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Registration accuracy enhancement of a surgical navigation system for anterior cruciate ligament reconstruction: A phantom and cadaveric study.

    Science.gov (United States)

    Kim, Youngjun; Lee, Byung Hoon; Mekuria, Kinde; Cho, Hyunchul; Park, Sehyung; Wang, Joon Ho; Lee, Deukhee

    2017-03-01

    Recently, surgical navigation systems have been widely used to improve the results of various orthopaedic surgeries. However, surgical navigation has not been successful in anterior cruciate ligament reconstruction, owing to its inaccuracy and inconvenience. This study investigated the registration of preoperative and intraoperative data, which are the key components in improving accuracy of the navigation system. An accurate registration method was proposed using new optical tracking markers and landmark retake. A surgical planning and navigation system for anterior cruciate ligament reconstruction was developed and implemented. The accuracy of the proposed system has been evaluated using phantoms and eight cadaveric knees. The present study investigated only the registration accuracy excluding the errors of optical tracking hardware and surgeon. The target registration errors of femoral tunnelling for anterior cruciate ligament reconstruction in phantoms were found to be 0.24±0.03mm and 0.19±0.10° for the tunnel entry position and tunnel direction, respectively. The target registration errors measured using cadavers were 0.9mm and 1.94°, respectively. The preclinical experimental results showed that the proposed methods enhanced the registration accuracy of the developed system. As the system becomes more accurate, surgeons could more precisely position and orient the femoral and tibial tunnels to their original anatomical locations. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Dosimetric study of a brachytherapy treatment of esophagus with Brazilian 192Ir sources using an anthropomorphic phantom

    Science.gov (United States)

    Neves, Lucio P.; Santos, William S.; Gorski, Ronan; Perini, Ana P.; Maia, Ana F.; Caldas, Linda V. E.; Orengo, Gilberto

    2014-11-01

    Several radioisotopes are produced at Instituto de Pesquisas Energéticas e Nucleares for the use in medical treatments, including the activation of 192Ir sources. These sources are suitable for brachytherapy treatments, due to their low or high activity, depending on the concentration of 192Ir, easiness to manufacture, small size, stable daughter products and the possibility of re-utilization. They may be used for the treatment of prostate, cervix, head and neck, skin, breast, gallbladder, uterus, vagina, lung, rectum, and eye cancer treatment. In this work, the use of some 192Ir sources was studied for the treatment of esophagus cancer, especially the dose determination of important structures, such as those on the mediastinum. This was carried out utilizing a FASH anthropomorphic phantom and the MCNP5 Monte Carlo code to transport the radiation through matter. It was possible to observe that the doses at lungs, breast, esophagus, thyroid and heart were the highest, which was expected due to their proximity to the source. Therefore, the data are useful to assess the representative dose specific to brachytherapy treatments on the esophagus for radiation protection purposes. The use of brachytherapy sources was studied for the treatment of esophagus cancer. FASH anthropomorphic phantom and MCNP5 Monte Carlo code were employed. The doses at lungs, breast, esophagus, thyroid and heart were the highest. The data is useful to assess the representative doses of treatments on the esophagus.

  3. 200 MeV Proton Radiography Studies with a Hand Phantom Using a Prototype Proton CT Scanner

    Science.gov (United States)

    Plautz, Tia; Bashkirov, V.; Feng, V.; Hurley, F.; Johnson, R.P.; Leary, C.; Macafee, S.; Plumb, A.; Rykalin, V.; Sadrozinski, H.F.-W.; Schubert, K.; Schulte, R.; Schultze, B.; Steinberg, D.; Witt, M.; Zatserklyaniy, A.

    2014-01-01

    Proton radiography has applications in patient alignment and verification procedures for proton beam radiation therapy. In this paper, we report an experiment which used 200 MeV protons to generate proton energy-loss and scattering radiographs of a hand phantom. The experiment used the first-generation proton CT scanner prototype, which was installed on the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center (LLUMC). It was found that while both radiographs displayed anatomical details of the hand phantom, the energy-loss radiograph had a noticeably higher resolution. Nonetheless, scattering radiography may yield more contrast between soft and bone tissue than energy-loss radiography, however, this requires further study. This study contributes to the optimization of the performance of the next-generation of clinical proton CT scanners. Furthermore, it demonstrates the potential of proton imaging (proton radiography and CT), which is now within reach of becoming available as a new, potentially low-dose medical imaging modality. PMID:24710156

  4. Treatment of phantom limb pain (PLP) based on augmented reality and gaming controlled by myoelectric pattern recognition: a case study of a chronic PLP patient.

    Science.gov (United States)

    Ortiz-Catalan, Max; Sander, Nichlas; Kristoffersen, Morten B; Håkansson, Bo; Brånemark, Rickard

    2014-01-01

    A variety of treatments have been historically used to alleviate phantom limb pain (PLP) with varying efficacy. Recently, virtual reality (VR) has been employed as a more sophisticated mirror therapy. Despite the advantages of VR over a conventional mirror, this approach has retained the use of the contralateral limb and is therefore restricted to unilateral amputees. Moreover, this strategy disregards the actual effort made by the patient to produce phantom motions. In this work, we investigate a treatment in which the virtual limb responds directly to myoelectric activity at the stump, while the illusion of a restored limb is enhanced through augmented reality (AR). Further, phantom motions are facilitated and encouraged through gaming. The proposed set of technologies was administered to a chronic PLP patient who has shown resistance to a variety of treatments (including mirror therapy) for 48 years. Individual and simultaneous phantom movements were predicted using myoelectric pattern recognition and were then used as input for VR and AR environments, as well as for a racing game. The sustained level of pain reported by the patient was gradually reduced to complete pain-free periods. The phantom posture initially reported as a strongly closed fist was gradually relaxed, interestingly resembling the neutral posture displayed by the virtual limb. The patient acquired the ability to freely move his phantom limb, and a telescopic effect was observed where the position of the phantom hand was restored to the anatomically correct distance. More importantly, the effect of the interventions was positively and noticeably perceived by the patient and his relatives. Despite the limitation of a single case study, the successful results of the proposed system in a patient for whom other medical and non-medical treatments have been ineffective justifies and motivates further investigation in a wider study.

  5. Treatment of phantom limb pain (PLP based on augmented reality and gaming controlled by myoelectric pattern recognition: a case study of a chronic PLP patient

    Directory of Open Access Journals (Sweden)

    Max eOrtiz-Catalan

    2014-02-01

    Full Text Available A variety of treatments have been historically used to alleviate phantom limb pain (PLP with varying efficacy. Recently, virtual reality (VR has been employed as a more sophisticated mirror therapy. Despite the advantages of VR over a conventional mirror, this approach has retained the use of the contralateral limb and is therefore restricted to unilateral amputees. Moreover, this strategy disregards the actual effort made by the patient to produce phantom motions. In this work, we investigate a treatment in which the virtual limb responds directly to myoelectric activity at the stump, while the illusion of a restored limb is enhanced through augmented reality (AR. Further, phantom motions are facilitated and encouraged through gaming.The proposed set of technologies was administered to a chronic PLP patient who has shown resistance to a variety of treatments (including mirror therapy for 48 years. Individual and simultaneous phantom movements were predicted using myoelectric pattern recognition and were then used as input for VR and AR environments, as well as for a racing game.The sustained level of pain reported by the patient was gradually reduced to complete pain-free periods. The phantom posture initially reported as a strongly closed fist was gradually relaxed, interestingly resembling the neutral posture displayed by the virtual limb. The patient acquired the ability to freely move his phantom limb and a telescopic effect was observed where the position of the phantom hand was restored to the anatomically correct distance. More importantly, the effect of the interventions was positively and noticeably perceived by the patient and his relatives.Despite the limitation of a single case study, the successful results of the proposed system in a patient for whom other medical and non-medical treatments have been ineffective justifies and motivates further investigation in a wider study.

  6. SU-F-T-136: Breath Hold Lung Phantom Study in Using CT Density Versus Relative Stopping Power Ratio for Proton Pencil Beam Scanning System

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J; Wu, H; Rosen, L [Willis-Knighton Medical Center, Shreveport, LA (United States)

    2016-06-15

    Purpose: To evaluate mass density effects of CT conversion table and its variation in current treatment planning system of spot scanning proton beam using an IROC proton lung phantom for this study. Methods: A proton lung phantom study was acquired to Imaging and Radiation Oncology Core Houston (IROC) Quality Assurance Center. Inside the lung phantom, GAF Chromic films and couples of thermal luminescent dosimeter (TLD) capsules embedded in specified PTV and adjacent structures to monitor delivered dosage and 3D dose distribution profiles. Various material such as cork (Lung), blue water (heart), Techron HPV (ribs) and organic material of balsa wood and cork as dosimetry inserts within phantom of solid water (soft tissue). Relative stopping power (RLSP) values were provided. Our treatment planning system (TPS) doesn’t require SP instead relative density was converted relative to water. However lung phantom was irradiated by planning with density override and the results were compared with IROC measurements. The second attempt was conducted without density override and compared with IROC’s. Results: The higher passing rate of imaging and measurement results of the lung phantom irradiation met the criteria by IROC without density override. The film at coronal plane was found to be shift due to inclined cylinder insertion. The converted CT density worked as expected to correlate relative stopping power. Conclusion: The proton lung phantom provided by IROC is a useful tool to qualify our commissioned proton pencil beam delivery with TPS within reliable confidence. The relative mass stopping power ratios of materials were converted from the relative physical density relative to water and the results were satisfied.

  7. Accuracy of Dose Delivery in Multiple Breath-Hold Segmented Volumetric Modulated Arc Therapy: A Static Phantom Study

    Directory of Open Access Journals (Sweden)

    Kimiya Noto

    2014-01-01

    Full Text Available Purpose. Accuracy of dose delivery in multiple breath-hold segmented volumetric modulated arc therapy (VMAT was evaluated in comparison to noninterrupted VMAT using a static phantom. Material and Methods. Five VMAT plans were evaluated. A Synergy linear accelerator (Elekta AB, Stockholm, Sweden was employed. A VMAT delivery sequence was divided into multiple segments according to each of the predefined breath-hold periods (10, 15, 20, 30, and 40 seconds. The segmented VMAT delivery was compared to noninterrupted VMAT delivery in terms of the isocenter dose and pass rates of a dose difference of 1% with a dose threshold of 10% of the maximum dose on a central coronal plane using a two-dimensional dosimeter, MatriXX Evolution (IBA Dosimetry, Schwarzenbruck, Germany. Results. Means of the isocenter dose differences were 0.5%, 0.2%, 0.2%, 0.0%, and 0.0% for the beam-on-times between interrupts of 10, 15, 20, 30, and 40 seconds, respectively. Means of the pass rates were 85%, 99.9%, 100%, 100%, and 100% in the same order as the above. Conclusion. Our static phantom study indicated that the multiple breath-hold segmented VMAT maintains stable and accurate dose delivery when the beam-on-time between interrupts is 15 seconds or greater.

  8. A new head-mounted display-based augmented reality system in neurosurgical oncology: a study on phantom.

    Science.gov (United States)

    Cutolo, Fabrizio; Meola, Antonio; Carbone, Marina; Sinceri, Sara; Cagnazzo, Federico; Denaro, Ennio; Esposito, Nicola; Ferrari, Mauro; Ferrari, Vincenzo

    2017-12-01

    Benefits of minimally invasive neurosurgery mandate the development of ergonomic paradigms for neuronavigation. Augmented Reality (AR) systems can overcome the shortcomings of commercial neuronavigators. The aim of this work is to apply a novel AR system, based on a head-mounted stereoscopic video see-through display, as an aid in complex neurological lesion targeting. Effectiveness was investigated on a newly designed patient-specific head mannequin featuring an anatomically realistic brain phantom with embedded synthetically created tumors and eloquent areas. A two-phase evaluation process was adopted in a simulated small tumor resection adjacent to Broca's area. Phase I involved nine subjects without neurosurgical training in performing spatial judgment tasks. In Phase II, three surgeons were involved in assessing the effectiveness of the AR-neuronavigator in performing brain tumor targeting on a patient-specific head phantom. Phase I revealed the ability of the AR scene to evoke depth perception under different visualization modalities. Phase II confirmed the potentialities of the AR-neuronavigator in aiding the determination of the optimal surgical access to the surgical target. The AR-neuronavigator is intuitive, easy-to-use, and provides three-dimensional augmented information in a perceptually-correct way. The system proved to be effective in guiding skin incision, craniotomy, and lesion targeting. The preliminary results encourage a structured study to prove clinical effectiveness. Moreover, our testing platform might be used to facilitate training in brain tumour resection procedures.

  9. Low contrast detectability and spatial resolution with model-based iterative reconstructions of MDCT images: a phantom and cadaveric study

    Energy Technology Data Exchange (ETDEWEB)

    Millon, Domitille; Coche, Emmanuel E. [Universite Catholique de Louvain, Department of Radiology and Medical Imaging, Cliniques Universitaires Saint Luc, Brussels (Belgium); Vlassenbroek, Alain [Philips Healthcare, Brussels (Belgium); Maanen, Aline G. van; Cambier, Samantha E. [Universite Catholique de Louvain, Statistics Unit, King Albert II Cancer Institute, Brussels (Belgium)

    2017-03-15

    To compare image quality [low contrast (LC) detectability, noise, contrast-to-noise (CNR) and spatial resolution (SR)] of MDCT images reconstructed with an iterative reconstruction (IR) algorithm and a filtered back projection (FBP) algorithm. The experimental study was performed on a 256-slice MDCT. LC detectability, noise, CNR and SR were measured on a Catphan phantom scanned with decreasing doses (48.8 down to 0.7 mGy) and parameters typical of a chest CT examination. Images were reconstructed with FBP and a model-based IR algorithm. Additionally, human chest cadavers were scanned and reconstructed using the same technical parameters. Images were analyzed to illustrate the phantom results. LC detectability and noise were statistically significantly different between the techniques, supporting model-based IR algorithm (p < 0.0001). At low doses, the noise in FBP images only enabled SR measurements of high contrast objects. The superior CNR of model-based IR algorithm enabled lower dose measurements, which showed that SR was dose and contrast dependent. Cadaver images reconstructed with model-based IR illustrated that visibility and delineation of anatomical structure edges could be deteriorated at low doses. Model-based IR improved LC detectability and enabled dose reduction. At low dose, SR became dose and contrast dependent. (orig.)

  10. Realistic analytical polyhedral MRI phantoms.

    Science.gov (United States)

    Ngo, Tri M; Fung, George S K; Han, Shuo; Chen, Min; Prince, Jerry L; Tsui, Benjamin M W; McVeigh, Elliot R; Herzka, Daniel A

    2016-08-01

    Analytical phantoms have closed form Fourier transform expressions and are used to simulate MRI acquisitions. Existing three-dimensional (3D) analytical phantoms are unable to accurately model shapes of biomedical interest. The goal of this study was to demonstrate that polyhedral analytical phantoms have closed form Fourier transform expressions and can accurately represent 3D biomedical shapes. The Fourier transform of a polyhedron was implemented and its accuracy in representing faceted and smooth surfaces was characterized. Realistic anthropomorphic polyhedral brain and torso phantoms were constructed and their use in simulated 3D and two-dimensional (2D) MRI acquisitions was described. Using polyhedra, the Fourier transform of faceted shapes can be computed to within machine precision. Smooth surfaces can be approximated with increasing accuracy by increasing the number of facets in the polyhedron; the additional accumulated numerical imprecision of the Fourier transform of polyhedra with many faces remained small. Simulations of 3D and 2D brain and 2D torso cine acquisitions produced realistic reconstructions free of high frequency edge aliasing compared with equivalent voxelized/rasterized phantoms. Analytical polyhedral phantoms are easy to construct and can accurately simulate shapes of biomedical interest. Magn Reson Med 76:663-678, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  11. Evaluation of strategies towards harmonization of FDG PET/CT studies in multicentre trials: comparison of scanner validation phantoms and data analysis procedures.

    Science.gov (United States)

    Makris, Nikolaos E; Huisman, Marc C; Kinahan, Paul E; Lammertsma, Adriaan A; Boellaard, Ronald

    2013-10-01

    PET quantification based on standardized uptake values (SUV) is hampered by several factors, in particular by variability in PET acquisition settings and data analysis methods. Quantitative PET/CT studies acquired during a multicentre trial require harmonization of imaging procedures to maximize study power. The aims of this study were to determine which phantoms are most suitable for detecting differences in image quality and quantification, and which methods for defining volumes of interest (VOI) are least sensitive to these differences. The most common accreditation phantoms used in oncology FDG PET/CT trials were scanned on the same scanner. These phantoms were those used by the Society of Nuclear Medicine Clinical Trials Network (SNM-CTN), the European Association of Nuclear Medicine/National Electrical Manufacturers Association (EANM/NEMA) and the American College of Radiology (ACR). In addition, tumour SUVs were derived from ten oncology whole-body examinations performed on the same PET/CT system. Both phantom and clinical data were reconstructed using different numbers of iterations, subsets and time-of-flight kernel widths. Subsequently, different VOI methods (VOI(A50%), VOI(max), VOI(3Dpeak), VOI(2Dpeak)) were applied to assess the impact of changes in image reconstruction settings on SUV and recovery coefficients (RC). All phantoms demonstrated sensitivity for detecting changes in SUV and RC measures in response to changes in image reconstruction settings and VOI analysis methods. The SNM-CTN and EANM/NEMA phantoms showed almost equal sensitivity in detecting RC differences with changes in image characteristics. Phantom and clinical data demonstrated that the VOI analysis methods VOI(A50%) and VOI(max) gave SUV and RC values with large variability in relation to image characteristics, whereas VOI(3Dpeak) and VOI(2Dpeak) were less sensitive to these differences. All three phantoms may be used to harmonize parameters for data acquisition, processing and

  12. Evaluation of strategies towards harmonization of FDG PET/CT studies in multicentre trials: comparison of scanner validation phantoms and data analysis procedures

    Energy Technology Data Exchange (ETDEWEB)

    Makris, Nikolaos E.; Huisman, Marc C.; Lammertsma, Adriaan A.; Boellaard, Ronald [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Kinahan, Paul E. [University of Washington, Imaging Research Laboratory, Department of Radiology, Seattle, WA (United States)

    2013-10-15

    PET quantification based on standardized uptake values (SUV) is hampered by several factors, in particular by variability in PET acquisition settings and data analysis methods. Quantitative PET/CT studies acquired during a multicentre trial require harmonization of imaging procedures to maximize study power. The aims of this study were to determine which phantoms are most suitable for detecting differences in image quality and quantification, and which methods for defining volumes of interest (VOI) are least sensitive to these differences. The most common accreditation phantoms used in oncology FDG PET/CT trials were scanned on the same scanner. These phantoms were those used by the Society of Nuclear Medicine Clinical Trials Network (SNM-CTN), the European Association of Nuclear Medicine/National Electrical Manufacturers Association (EANM/NEMA) and the American College of Radiology (ACR). In addition, tumour SUVs were derived from ten oncology whole-body examinations performed on the same PET/CT system. Both phantom and clinical data were reconstructed using different numbers of iterations, subsets and time-of-flight kernel widths. Subsequently, different VOI methods (VOI{sub A50%,} VOI{sub max}, VOI{sub 3Dpeak,} VOI{sub 2Dpeak}) were applied to assess the impact of changes in image reconstruction settings on SUV and recovery coefficients (RC). All phantoms demonstrated sensitivity for detecting changes in SUV and RC measures in response to changes in image reconstruction settings and VOI analysis methods. The SNM-CTN and EANM/NEMA phantoms showed almost equal sensitivity in detecting RC differences with changes in image characteristics. Phantom and clinical data demonstrated that the VOI analysis methods VOI{sub A50%} and VOI{sub max} gave SUV and RC values with large variability in relation to image characteristics, whereas VOI{sub 3Dpeak} and VOI{sub 2Dpeak} were less sensitive to these differences. All three phantoms may be used to harmonize parameters for

  13. Thick slices from tomosynthesis data sets: phantom study for the evaluation of different algorithms.

    Science.gov (United States)

    Diekmann, Felix; Meyer, Henning; Diekmann, Susanne; Puong, Sylvie; Muller, Serge; Bick, Ulrich; Rogalla, Patrik

    2009-10-01

    Tomosynthesis is a 3-dimensional mammography technique that generates thin slices separated one to the other by typically 1 mm from source data sets. The relatively high image noise in these thin slices raises the value of 1-cm thick slices computed from the set of reconstructed slices for image interpretation. In an initial evaluation, we investigated the potential of different algorithms for generating thick slices from tomosynthesis source data (maximum intensity projection-MIP; average algorithm-AV, and image generation by means of a new algorithm, so-called softMip). The three postprocessing techniques were evaluated using a homogeneous phantom with one textured slab with a total thickness of about 5 cm in which two 0.5-cm-thick slabs contained objects to simulate microcalcifications, spiculated masses, and round masses. The phantom was examined by tomosynthesis (GE Healthcare). Microcalcifications were simulated by inclusion of calcium particles of four different sizes. The slabs containing the inclusions were examined in two different configurations: adjacent to each other and close to the detector and with the two slabs separated by two 1-cm thick breast equivalent material slabs. The reconstructed tomosynthesis slices were postprocessed using MIP, AV, and softMip to generate 1-cm thick slices with a lower noise level. The three postprocessing algorithms were assessed by calculating the resulting contrast versus background for the simulated microcalcifications and contrast-to-noise ratios (CNR) for the other objects. The CNRs of the simulated round and spiculated masses were most favorable for the thick slices generated with the average algorithm, followed by softMip and MIP. Contrast of the simulated microcalcifications was best for MIP, followed by softMip and average projections. Our results suggest that the additional generation of thick slices may improve the visualization of objects in tomosynthesis. This improvement differs from the different

  14. Influence of dose reduction and iterative reconstruction on CT calcium scores : a multi-manufacturer dynamic phantom study

    NARCIS (Netherlands)

    van der Werf, N R; Willemink, M J; Willems, T P; Greuter, M J W; Leiner, T

    To evaluate the influence of dose reduction in combination with iterative reconstruction (IR) on coronary calcium scores (CCS) in a dynamic phantom on state-of-the-art CT systems from different manufacturers. Calcified inserts in an anthropomorphic chest phantom were translated at 20 mm/s

  15. Post-mortem computed tomography angiography utilizing barium sulfate to identify microvascular structures : a preliminary phantom model and case study

    NARCIS (Netherlands)

    Haakma, Wieke; Rohde, Marianne; Kuster, Lidy; Uhrenholt, Lars; Pedersen, Michael; Boel, Lene Warner Thorup

    2016-01-01

    We investigated the use of computer tomography angiography (CTA) to visualize microvascular structures in a vessel-mimicking phantom and post-mortem (PM) bodies. A contrast agent was used based on 22% barium sulfate, 20% polyethylene glycol and 58% distilled water. A vessel-mimicking phantom

  16. Psychophysical correlates of phantom limb experience.

    Science.gov (United States)

    Katz, J

    1992-01-01

    Phantom limb phenomena were correlated with psychophysiological measures of peripheral sympathetic nervous system activity measured at the amputation stump and contralateral limb. Amputees were assigned to one of three groups depending on whether they reported phantom limb pain, non-painful phantom limb sensations, or no phantom limb at all. Skin conductance and skin temperature were recorded continuously during two 30 minute sessions while subjects continuously monitored and rated the intensity of any phantom limb sensation or pain they experienced. The results from both sessions showed that mean skin temperature was significantly lower at the stump than the contralateral limb in the groups with phantom limb pain and non-painful phantom limb sensations, but not among subjects with no phantom limb at all. In addition, stump skin conductance responses correlated significantly with the intensity of non-painful phantom limb paresthesiae but not other qualities of sensation or pain. Between-limb measures of pressure sensitivity were not significantly different in any group. The results suggest that the presence of a phantom limb, whether painful or painless, is related to the sympathetic-efferent outflow of cutaneous vasoconstrictor fibres in the stump and stump neuromas. The hypothesis of a sympathetic-efferent somatic-afferent mechanism involving both sudomotor and vasoconstrictor fibres is proposed to explain the relationship between stump skin conductance responses and non-painful phantom limb paresthesiae. It is suggested that increases in the intensity of phantom limb paresthesiae follow bursts of sympathetic activity due to neurotransmitter release onto apposing sprouts of large diameter primary afferents located in stump neuromas, and decreases correspond to periods of relative sympathetic inactivity. The results of the study agree with recent suggestions that phantom limb pain is not a unitary syndrome, but a symptom class with each class subserved by

  17. Evaluation of the effect of machine settings on quantitative three-dimensional power Doppler angiography: an in-vitro flow phantom experiment.

    Science.gov (United States)

    Raine-Fenning, N J; Nordin, N M; Ramnarine, K V; Campbell, B K; Clewes, J S; Perkins, A; Johnson, I R

    2008-09-01

    Three-dimensional (3D) ultrasound is being used increasingly to acquire and subsequently quantify power Doppler data within the clinical setting. One proprietary software package calculates three 3D vascular indices: the vascularization index (VI), the flow index (FI), and the vascularization flow index (VFI). Our aim was to evaluate how different settings affect the Doppler signal in terms of its quantification by these three indices within a 3D dataset. A computer-driven 'flow phantom' was used to continuously pump a nylon particle-based blood mimic (Orgasol(trade mark)) around a closed system through a C-flex(trade mark) tube embedded in an agar-based tissue mimic. The test tanks were insonated with a modified 3D transvaginal 4-8-MHz ultrasound transducer (V530D) and power Doppler data were acquired over a series of different settings. Each experiment involved the manipulation of just one Doppler setting in order to study it in isolation. As expected, all of the power Doppler settings, when altered, were found to effect significant changes (P effect, producing no Doppler signals at the lowest settings and the highest recordable indices at the maximum settings. The pulse repetition frequency (PRF) was the next most influential setting but a Doppler signal was seen and measurable at all of the different settings. The other Doppler settings had a much less profound effect on the vascular indices, with subtle but significantly different measures across the full range of settings. The speed of data acquisition was also found to affect the vascular indices, all of which were reduced when the fast mode was used although the only significant effect was on the VFI. The VI, FI and VFI are all affected significantly by variations in power Doppler settings and by the speed of acquisition. The gain and signal power have the greatest effect on the power Doppler signal, followed closely by the PRF. The other settings and speed of acquisition also influence the signal, but to a

  18. The effects of iterative reconstruction in CT on low-contrast liver lesion volumetry: a phantom study

    Science.gov (United States)

    Li, Qin; Berman, Benjamin P.; Schumacher, Justin; Liang, Yongguang; Gavrielides, Marios A.; Yang, Hao; Zhao, Binsheng; Petrick, Nicholas

    2017-03-01

    Tumor volume measured from computed tomography images is considered a biomarker for disease progression or treatment response. The estimation of the tumor volume depends on the imaging system parameters selected, as well as lesion characteristics. In this study, we examined how different image reconstruction methods affect the measurement of lesions in an anthropomorphic liver phantom with a non-uniform background. Iterative statistics-based and model-based reconstructions, as well as filtered back-projection, were evaluated and compared in this study. Statistics-based and filtered back-projection yielded similar estimation performance, while model-based yielded higher precision but lower accuracy in the case of small lesions. Iterative reconstructions exhibited higher signal-to-noise ratio but slightly lower contrast of the lesion relative to the background. A better understanding of lesion volumetry performance as a function of acquisition parameters and lesion characteristics can lead to its incorporation as a routine sizing tool.

  19. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    Science.gov (United States)

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  20. Influence of difference in cross-sectional dose profile in a CTDI phantom on X-ray CT dose estimation: a Monte Carlo study.

    Science.gov (United States)

    Haba, Tomonobu; Koyama, Shuji; Ida, Yoshihiro

    2014-01-01

    The longitudinal dose profile in a computed tomography dose index (CTDI) phantom had been studied by many researchers. The cross-sectional dose profile in the CTDI phantom, however, has not been studied. It is also important to understand the cross-sectional dose profile in the CTDI phantom for dose estimation in X-ray CT. In this study, the cross-sectional dose profile in the CTDI phantom was calculated by use of a Monte Carlo (MC) simulation method. A helical or a 320-detector-row cone-beam X-ray CT scanner was simulated. The cross-sectional dose profile in the CTDI phantom from surface to surface through the center point was calculated by MC simulation. The shape of the calculation region was a cylinder of 1-mm-diameter. The length of the cylinder was 23, 100, or 300 mm to represent various CT ionization chamber lengths. Detailed analyses of the energy depositions demonstrated that the cross-sectional dose profile was different in measurement methods and phantom sizes. In this study, we also focused on the validation of the weighting factor used in weighted CTDI (CTDI w ). As it stands now, the weighting factor used in CTDI w is (1/3, 2/3) for the (central, peripheral) axes. Our results showed that an equal weighting factor, which is (1/2, 1/2) for the (central, peripheral) axes, is more suitable to estimate the average cross-sectional dose when X-ray CT dose estimation is performed.

  1. A phantom study on fetal dose reducing factors in pregnant patients with breast cancer during radiotherapy treatment

    Directory of Open Access Journals (Sweden)

    Akın Ogretici

    2017-01-01

    Full Text Available Purpose: This study aims to investigate the factors that reduce fetal dose in pregnant patients with breast cancer throughout their radiation treatment. Two main factors in a standard radiation oncology center are considered as the treatment planning systems (TPSs and simple shielding for intensity modulated radiation therapy technique. Materials and Methods: TPS factor was evaluated with two different planning algorithms: Anisotropic analytical algorithm and Acuros XB (external beam. To evaluate the shielding factor, a standard radiological purpose lead apron was chosen. For both studies, thermoluminescence dosimeters were used to measure the point dose, and an Alderson RANDO-phantom was used to simulate a female pregnant patient in this study. Thirteen measurement points were chosen in the 32nd slice of the phantom to cover all possible locations of a fetus up to 8th week of gestation. Results: The results show that both of the TPS algorithms are incapable of calculating the fetal doses, therefore, unable to reduce them at the planning stage. Shielding with a standard lead apron, however, showed a slight radiation protection (about 4.7% to the fetus decreasing the mean fetal dose from 84.8 mGy to 80.8 mGy, which cannot be disregarded in case of fetal irradiation. Conclusions: Using a lead apron for shielding the abdominal region of a pregnant patient during breast irradiation showed a minor advantage; however, its possible side effects (i.e., increased scattered radiation and skin dose should also be investigated further to solidify its benefits.

  2. Influence of contrast media viscosity and temperature on injection pressure in computed tomographic angiography: a phantom study.

    Science.gov (United States)

    Kok, Madeleine; Mihl, Casper; Mingels, Alma A; Kietselaer, Bas L; Mühlenbruch, Georg; Seehofnerova, Anna; Wildberger, Joachim E; Das, Marco

    2014-04-01

    Iodinated contrast media (CM) in computed tomographic angiography is characterized by its concentration and, consecutively, by its viscosity. Viscosity itself is directly influenced by temperature, which will furthermore affect injection pressure. Therefore, the purposes of this study were to systematically evaluate the viscosity of different CM at different temperatures and to assess their impact on injection pressure in a circulation phantom. Initially, viscosity of different contrast media concentrations (240, 300, 370, and 400 mgI/mL) was measured at different temperatures (20°C-40°C) with a commercially available viscosimeter. In the next step, a circulation phantom with physical conditions was used. Contrast media were prepared at different temperatures (20°C, 30°C, 37°C) and injected through a standard 18-gauge needle. All other relevant parameters were kept constant (iodine delivery rate, 1.9 g I/s; total amount of iodine, 15 g I). Peak flow rate (in milliliter per second) and injection pressure (psi) were monitored. Differences in significance were tested using the Kruskal-Wallis test (Statistical Package for the Social Sciences). Viscosities for iodinated CM of 240, 300, 370, and 400 mg I/mL at 20°C were 5.1, 9.1, 21.2, and 28.8 mPa.s, respectively, whereas, at 40°C, these were substantially lower (2.8, 4.4, 8.7, and 11.2 mPa.s). In the circulation phantom, mean (SD) peak pressures for CM of 240 mg I/mL at 20°C, 30°C, and 37°C were 107 (1.5), 95 (0.6), and 92 (2.1) psi; for CM of 300 mg I/mL, 119 (1.5), 104 (0.6), and 100 (3.6) psi; for CM of 370 mg I/mL, 150 (0.6), 133 (4.4), and 120 (3.5) psi; and for CM of 400 mg I/mL, 169 (1.0), 140 (2.1), and 135 (2.9) psi, respectively, with all P values less than 0.05. Low concentration, low viscosity, and high temperatures of CM are beneficial in terms of injection pressure. This should also be considered for individually tailored contrast protocols in daily routine scanning.

  3. SU-E-T-562: Motion Tracking Optimization for Conformal Arc Radiotherapy Plans: A QUASAR Phantom Based Study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z; Wang, I; Yao, R; Podgorsak, M [Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: This study is to use plan parameters optimization (Dose rate, collimator angle, couch angle, initial starting phase) to improve the performance of conformal arc radiotherapy plans with motion tracking by increasing the plan performance score (PPS). Methods: Two types of 3D conformal arc plans were created based on QUASAR respiratory motion phantom with spherical and cylindrical targets. Sinusoidal model was applied to the MLC leaves to generate motion tracking plans. A MATLAB program was developed to calculate PPS of each plan (ranges from 0–1) and optimize plan parameters. We first selected the dose rate for motion tracking plans and then used simulated annealing algorithm to search for the combination of the other parameters that resulted in the plan of the maximal PPS. The optimized motion tracking plan was delivered by Varian Truebeam Linac. In-room cameras and stopwatch were used for starting phase selection and synchronization between phantom motion and plan delivery. Gaf-EBT2 dosimetry films were used to measure the dose delivered to the target in QUASAR phantom. Dose profiles and Truebeam trajectory log files were used for plan delivery performance evaluation. Results: For spherical target, the maximal PPS (PPSsph) of the optimized plan was 0.79: (Dose rate: 500MU/min, Collimator: 90°, Couch: +10°, starting phase: 0.83π). For cylindrical target, the maximal PPScyl was 0.75 (Dose rate: 300MU/min, Collimator: 87°, starting phase: 0.97π) with couch at 0°. Differences of dose profiles between motion tracking plans (with the maximal and the minimal PPS) and 3D conformal plans were as follows: PPSsph=0.79: %ΔFWHM: 8.9%, %Dmax: 3.1%; PPSsph=0.52: %ΔFWHM: 10.4%, %Dmax: 6.1%. PPScyl=0.75: %ΔFWHM: 4.7%, %Dmax: 3.6%; PPScyl=0.42: %ΔFWHM: 12.5%, %Dmax: 9.6%. Conclusion: By achieving high plan performance score through parameters optimization, we can improve target dose conformity of motion tracking plan by decreasing total MLC leaf travel distance

  4. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chuan, E-mail: chuan.huang@stonybrookmedicine.edu [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Departments of Radiology, Psychiatry, Stony Brook Medicine, Stony Brook, New York 11794 (United States); Petibon, Yoann [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Ouyang, Jinsong; El Fakhri, Georges [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Reese, Timothy G. [Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 and Martinos Center for Biomedical Imaging, Charlestown, Massachusetts 02129 (United States); Ahlman, Mark A.; Bluemke, David A. [Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, Maryland 20892 (United States)

    2015-02-15

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  5. Comparison of radiation dose to operator between transradial and transfemoral coronary angiography with optimised radiation protection: a phantom study.

    Science.gov (United States)

    Liu, Huiliang; Jin, Zhigeng; Jing, Limin

    2014-03-01

    A growing concern in applying radial access in cardiac catheterisation is the increased operator radiation exposure. This study used an anthropomorphic phantom to simulate transradial and transfemoral coronary angiography with optimised radiation protection conditions. Operator radiation exposure was measured with thermoluminescent dosemeters at predefined locations. Compared with the femoral route, the radial route was associated with a dose decrease of 15 % at the operator's chest level with optimised radiation shielding. However, radiation exposure to the operator's hand remained significantly higher when applying radial access even with collective protective equipment used (by a factor of 2). Furthermore, the efficiency of operator radiation protection was found to be dependent on the tube incidence. Awareness should be raised about the significant increase of radiation exposure to operators' hands in transradial coronary angiography. Protection to reduce the dose level to the hands is necessary and should be further improved.

  6. High-Definition Computed Tomography for Coronary Artery Stent Imaging: a Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Wen Jie; Chen, Ke Min; Pang, Li Fang; Zhang, Huang; Pan, Zi Lai [Rui Jin Hospital, Medical School, Shanghai Jiao Tong University, Shangha (China); Guo, Ying; Li, Jian Ying [Beijing Economic and Technology Development Area, Beijing (China)

    2012-01-15

    To assess the performance of a high-definition CT (HDCT) for imaging small caliber coronary stents ({<=} 3 mm) by comparing different scan modes of a conventional 64-row standard-definition CT (SDCT). A cardiac phantom with twelve stents (2.5 mm and 3.0 mm in diameter) was scanned by HDCT and SDCT. The scan modes were retrospective electrocardiography (ECG)-gated helical and prospective ECG-triggered axial with tube voltages of 120 kVp and 100 kVp, respectively. The inner stent diameters (ISD) and the in-stent attenuation value (AVin-stent) and the in-vessel extra-stent attenuation value (AVin-vessel) were measured by two observers. The artificial lumen narrowing (ALN = [ISD - ISDmeasured]/ISD) and artificial attenuation increase between in-stent and in-vessel (AAI = AVin-stent - AVin-vessel) were calculated. All data was analyzed by intraclass correlation and ANOVA-test. The correlation coefficient of ISD, AVin-vessel and AVin-stent between the two observers was good. The ALNs of HDCT were statistically lower than that of SDCT (30 {+-} 5.7% versus 35 {+-} 5.4%, p < 0.05). HDCT had statistically lower AAI values than SDCT (15.7 {+-} 81.4 HU versus 71.4 {+-} 90.5 HU, p < 0.05). The prospective axial dataset demonstrated smaller ALN than the retrospective helical dataset on both HDCT and SDCT (p < 0.05). Additionally, there were no differences in ALN between the 120 kVp and 100 kVp tube voltages on HDCT (p = 0.05). High-definition CT helps improve measurement accuracy for imaging coronary stents compared to SDCT. HDCT with 100 kVp and the prospective ECG-triggered axial technique, with a lower radiation dose than 120 kVp application, may be advantageous in evaluating coronary stents with smaller calibers ({<=} 3 mm).

  7. Evaluation of a portable image overlay projector for the visualisation of surgical navigation data: phantom studies.

    Science.gov (United States)

    Gavaghan, K; Oliveira-Santos, T; Peterhans, M; Reyes, M; Kim, H; Anderegg, S; Weber, S

    2012-07-01

    Presenting visual feedback for image-guided surgery on a monitor requires the surgeon to perform time-consuming comparisons and diversion of sight and attention away from the patient. Deficiencies in previously developed augmented reality systems for image-guided surgery have, however, prevented the general acceptance of any one technique as a viable alternative to monitor displays. This work presents an evaluation of the feasibility and versatility of a novel augmented reality approach for the visualisation of surgical planning and navigation data. The approach, which utilises a portable image overlay device, was evaluated during integration into existing surgical navigation systems and during application within simulated navigated surgery scenarios. A range of anatomical models, surgical planning data and guidance information taken from liver surgery, cranio-maxillofacial surgery, orthopaedic surgery and biopsy were displayed on patient-specific phantoms, directly on to the patient's skin and on to cadaver tissue. The feasibility of employing the proposed augmented reality visualisation approach in each of the four tested clinical applications was qualitatively assessed for usability, visibility, workspace, line of sight and obtrusiveness. The visualisation approach was found to assist in spatial understanding and reduced the need for sight diversion throughout the simulated surgical procedures. The approach enabled structures to be identified and targeted quickly and intuitively. All validated augmented reality scenes were easily visible and were implemented with minimal overhead. The device showed sufficient workspace for each of the presented applications, and the approach was minimally intrusiveness to the surgical scene. The presented visualisation approach proved to be versatile and applicable to a range of image-guided surgery applications, overcoming many of the deficiencies of previously described AR approaches. The approach presents an initial step

  8. In vitro validation and comparison of different software packages or algorithms for coronary bifurcation analysis using calibrated phantoms: implications for clinical practice and research of bifurcation stenting.

    Science.gov (United States)

    Ishibashi, Yuki; Grundeken, Maik J; Nakatani, Shimpei; Iqbal, Javaid; Morel, Marie-Angele; Généreux, Philippe; Girasis, Chrysafios; Wentzel, Jolanda J; Garcia-Garcia, Hector M; Onuma, Yoshinobu; Serruys, Patrick W

    2015-03-01

    The accuracy and precision of quantitative coronary angiography (QCA) software dedicated for bifurcation lesions compared with conventional single-vessel analysis remains unknown. Furthermore, comparison of different bifurcation analysis algorithms has not been performed. Six plexiglas phantoms with 18 bifurcations were manufactured with a tolerance Analysis System (CAAS; Version 5.10, Pie Medical Imaging, Maastricht, The Netherlands) and QAngio XA (Version 7.3, Medis Medical Imaging System BV, Leiden, The Netherlands) software packages. Conventional single-vessel analysis underestimated the reference vessel diameter and percent diameter stenosis in the proximal main vessel while it overestimated these parameters in the distal main vessel and side branch. CAAS software showed better overall accuracy and precision than QAngio XA (with automatic Y- or T-shape bifurcation algorithm selection) for various phantom diameters including minimum lumen diameter (0.012 ± 0.103 mm vs. 0.041 ± 0.322 mm, P = 0.003), reference vessel diameter (-0.050 ± 0.043 mm vs. 0.116 ± 0.610 mm, P = 0.026), and % diameter stenosis (-0.94 ± 4.07 % vs. 1.74 ± 7.49 %, P = 0.041). QAngio XA demonstrated higher minimal lumen diameter, reference vessel diameter, and % diameter stenosis when compared to the actual phantom diameters; however, the accuracy of these parameters improved to a similar level as CAAS when the sole T-shape algorithm in the QAnxio XA was used. The use of the single-vessel QCA method is inaccurate in bifurcation lesions. Both CAAS and QAngio XA (when the T shape is systematically used) bifurcation software packages are suitable for quantitative assessment of bifurcations. © 2014 Wiley Periodicals, Inc.

  9. Magnetic resonance lung function – a breakthrough for lung imaging and functional assessment? A phantom study and clinical trial

    Directory of Open Access Journals (Sweden)

    Rauh Manfred

    2006-08-01

    Full Text Available Abstract Background Chronic lung diseases are a major issue in public health. A serial pulmonary assessment using imaging techniques free of ionizing radiation and which provides early information on local function impairment would therefore be a considerably important development. Magnetic resonance imaging (MRI is a powerful tool for the static and dynamic imaging of many organs. Its application in lung imaging however, has been limited due to the low water content of the lung and the artefacts evident at air-tissue interfaces. Many attempts have been made to visualize local ventilation using the inhalation of hyperpolarized gases or gadolinium aerosol responding to MRI. None of these methods are applicable for broad clinical use as they require specific equipment. Methods We have shown previously that low-field MRI can be used for static imaging of the lung. Here we show that mathematical processing of data derived from serial MRI scans during the respiratory cycle produces good quality images of local ventilation without any contrast agent. A phantom study and investigations in 85 patients were performed. Results The phantom study proved our theoretical considerations. In 99 patient investigations good correlation (r = 0.8; p ≤ 0.001 was seen for pulmonary function tests and MR ventilation measurements. Small ventilation defects were visualized. Conclusion With this method, ventilation defects can be diagnosed long before any imaging or pulmonary function test will indicate disease. This surprisingly simple approach could easily be incorporated in clinical routine and may be a breakthrough for lung imaging and functional assessment.

  10. Evidence-based recommendations for musculoskeletal kinematic 4D-CT studies using wide area-detector scanners: a phantom study with cadaveric correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto; Formery, Anne-Sophie; Blum, Alain [CHRU-Nancy Hopital Central, Service d' Imagerie Guilloz, Nancy (France); Hossu, Gabriela [Universite de Lorraine, IADI U947, Nancy (France); INSERM, CIC-IT 1433, Nancy (France); Winninger, Daniel [IDCmem, Nancy (France); Batch, Toufik [Hopital de Mercy, Service de Radiologie, Metz (France); Gervaise, Alban [Legouest Military Instruction Hospital, Medical Imaging Department, Metz (France)

    2017-02-15

    To establish evidence-based recommendations for musculoskeletal kinematic 4D-CT on wide area-detector CT. In order to assess factors influencing image quality in kinematic CT studies, a phantom consisting of a polymethylmethacrylate rotating disk with round wells of different sizes was imaged with various acquisition protocols. Cadaveric acquisitions were performed on the ankle joint during motion in two different axes and at different speeds to allow validation of phantom data. Images were acquired with a 320 detector-row CT scanner and were evaluated by two readers. Motion artefacts were significantly correlated with various parameters (movement axis, distance to centre, rotation speed and volume acquisition speed) (p < 0.0001). The relation between motion artefacts and distance to motion fulcrum was exponential (R{sup 2} 0.99). Half reconstruction led to a 23 % increase in image noise and a 40 % decrease in motion artefacts. Cadaveric acquisitions confirmed phantom data. Based on these findings, high tube rotation speed and half reconstruction are recommended for kinematic CT. The axis of motion significantly influences image artefacts and should be considered in patient training and evaluation of acquisition protocol suitability. This study provides evidence-based recommendations for musculoskeletal kinematic 4D-CT. (orig.)

  11. Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Maria; Honey, Ian [Trust, Medical Physics Department, Guy' s and St. Thomas' NHS Foundation, London (United Kingdom); Goh, Vicky [King' s College London, St Thomas' Hospital, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Beggs, Shaun [Bradford Teaching Hospitals NHS Foundation Trust, Radiation Physics Services, Bradford (United Kingdom); Bridges, Andrew; Wayte, Sarah [Radiology Physics University Hospitals Coventry and Warwickshire NHS Trust, Coventry (United Kingdom); Clewer, Philip [Medical Physics Department, University Hospital Southampton NHS Foundation Trust, Southampton (United Kingdom); Davis, Anne [Portsmouth Hospitals NHS Trust, Medical Physics Department, Portsmouth (United Kingdom); Foy, Trevelyan [Royal Cornwall Hospital NHS Trust, Medical Physics Department, Truro (United Kingdom); Fuller, Karen [Sheffield Teaching Hospitals NHS Foundation Trust, Medical Physics Department, Sheffield (United Kingdom); George, Jennifer [University Hospital of North Staffordshire NHS Trust, Medical Physics Department, Stoke-on-Trent (United Kingdom); Higginson, Antony [Portsmouth Hospitals NHS Trust, Department of Radiology, Portsmouth (United Kingdom); Iball, Gareth [Leeds Teaching Hospitals NHS Trust, Department of Medical Physics and Engineering, Leeds (United Kingdom); Mutch, Steve [Oxford University Hospitals NHS Trust, Radiation Physics and Protection Department, Oxford (United Kingdom); Neil, Shellagh; Sutton, David [NHS Tayside, Medical Physics Department, Dundee, Scotland (United Kingdom); Rivett, Cat [Plymouth Hospitals NHS Trust, Clinical and Radiation Physics, Plymouth (United Kingdom); Slater, Andrew [Oxford University Hospitals NHS Trust, Department of Radiology, Oxford (United Kingdom); Weir, Nick [Queen' s Medical Research Institute, Clinical Research Imaging Centre, Edinburgh, Scotland (United Kingdom); Collaboration: on behalf of the PROSPeCT Investigators

    2014-09-15

    To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer. A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated. Radiation doses (CTDI{sub vol}, DLP) were compared across all sites. There was a linear relationship between CT number and iodine density. Iodine enhancement varied by a factor of at most 1.10, and image noise by at most 1.5 across the study sites. At an iodine concentration of 1 mg ml{sup -1} and 100 kV, CNRs ranged from 3.6 to 4.8 in the 220-mm phantom and from 1.4 to 1.9 in the 300-mm phantom. Doses varied by a factor of at most 2.4, but remained within study dose constraints. Iterative reconstruction algorithms did not alter iodine enhancement but resulted in reduced image noise by a factor of at most 2.2, allowing a potential dose decrease of at most 80 % compared to filtered back projection (FBP). Quality control of CT performance across centres indicates that CNR values remain relatively consistent across all sites, giving acceptable image quality within the agreed dose constraints. (orig.)

  12. Evaluation of the setup margins for cone beam computed tomography-guided cranial radiosurgery: A phantom study.

    Science.gov (United States)

    Calvo Ortega, Juan Francisco; Wunderink, Wouter; Delgado, David; Moragues, Sandra; Pozo, Miquel; Casals, Joan

    2016-01-01

    The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square field and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient׳s direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1mm in LR direction, and 0.7mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1mm in our CBCT-guided SRS approach. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  13. Multi-centre evaluation of accuracy and reproducibility of planar and SPECT image quantification. An IAEA phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Brian E. [National Institute of Standards and Technology, Gaithersburg, MD (United States); Grosev, Darko [Univ. Hospital Centre Zagreb (Croatia); Buvat, Irene [Service Hospitalier Frederic Joliot, Paris (France); and others

    2017-08-01

    Accurate quantitation of activity provides the basis for internal dosimetry of targeted radionuclide therapies. This study investigated quantitative imaging capabilities at sites with a variety of experience and equipment and assessed levels of errors in activity quantitation in Single-Photon Emission Computed Tomography (SPECT) and planar imaging. Participants from 9 countries took part in a comparison in which planar, SPECT and SPECT with X ray computed tomography (SPECT-CT) imaging were used to quantify activities of four epoxy-filled cylinders containing {sup 133}Ba, which was chosen as a surrogate for {sup 131}I. The sources, with nominal volumes of 2, 4, 6 and 23 mL, were calibrated for {sup 133}Ba activity by the National Institute of Standards and Technology, but the activity was initially unknown to the participants. Imaging was performed in a cylindrical phantom filled with water. Two trials were carried out in which the participants first estimated the activities using their local standard protocols, and then repeated the measurements using a standardized acquisition and analysis protocol. Finally, processing of the imaging data from the second trial was repeated by a single centre using a fixed protocol. In the first trial, the activities were underestimated by about 15% with planar imaging. SPECT with Chang's first order attenuation correction (Chang-AC) and SPECT-CT overestimated the activity by about 10%. The second trial showed moderate improvements in accuracy and variability. Planar imaging was subject to methodological errors, e.g., in the use of a transmission scan for attenuation correction. The use of Chang-AC was subject to variability from the definition of phantom contours. The project demonstrated the need for training and standardized protocols to achieve good levels of quantitative accuracy and precision in a multicentre setting. Absolute quantification of simple objects with no background was possible with the strictest protocol to

  14. Specification and estimation of sources of bias affecting neurological studies in PET/MR with an anatomical brain phantom

    Science.gov (United States)

    Teuho, J.; Johansson, J.; Linden, J.; Saunavaara, V.; Tolvanen, T.; Teräs, M.

    2014-01-01

    Selection of reconstruction parameters has an effect on the image quantification in PET, with an additional contribution from a scanner-specific attenuation correction method. For achieving comparable results in inter- and intra-center comparisons, any existing quantitative differences should be identified and compensated for. In this study, a comparison between PET, PET/CT and PET/MR is performed by using an anatomical brain phantom, to identify and measure the amount of bias caused due to differences in reconstruction and attenuation correction methods especially in PET/MR. Differences were estimated by using visual, qualitative and quantitative analysis. The qualitative analysis consisted of a line profile analysis for measuring the reproduction of anatomical structures and the contribution of the amount of iterations to image contrast. The quantitative analysis consisted of measurement and comparison of 10 anatomical VOIs, where the HRRT was considered as the reference. All scanners reproduced the main anatomical structures of the phantom adequately, although the image contrast on the PET/MR was inferior when using a default clinical brain protocol. Image contrast was improved by increasing the amount of iterations from 2 to 5 while using 33 subsets. Furthermore, a PET/MR-specific bias was detected, which resulted in underestimation of the activity values in anatomical structures closest to the skull, due to the MR-derived attenuation map that ignores the bone. Thus, further improvements for the PET/MR reconstruction and attenuation correction could be achieved by optimization of RAMLA-specific reconstruction parameters and implementation of bone to the attenuation template.

  15. Phantom breast syndrome

    Directory of Open Access Journals (Sweden)

    Ramesh

    2009-01-01

    Full Text Available Phantom breast syndrome is a type of condition in which patients have a sensation of residual breast tissue and can include both non-painful sensations as well as phantom breast pain. The incidence varies in different studies, ranging from approximately 30% to as high as 80% of patients after mastectomy. It seriously affects quality of life through the combined impact of physical disability and emotional distress. The breast cancer incidence rate in India as well as Western countries has risen in recent years while survival rates have improved; this has effectively increased the number of women for whom post-treatment quality of life is important. In this context, chronic pain following treatment for breast cancer surgery is a significantly under-recognized and under-treated problem. Various types of chronic neuropathic pain may arise following breast cancer surgery due to surgical trauma. The cause of these syndromes is damage to various nerves during surgery. There are a number of assumed factors causing or perpetuating persistent neuropathic pain after breast cancer surgery. Most well-established risk factors for developing phantom breast pain and other related neuropathic pain syndromes are severe acute postoperative pain and greater postoperative use of analgesics. Based upon current evidence, the goals of prophylactic strategies could first target optimal peri-operative pain control and minimizing damage to nerves during surgery. There is some evidence that chronic pain and sensory abnormalities do decrease over time. The main group of oral medications studied includes anti-depressants, anticonvulsants, opioids, N-methyl-D-asparate receptor antagonists, mexilitine, topical lidocaine, cannabinoids, topical capsaicin and glysine antagonists. Neuromodulation techniques such as motor cortex stimulation, spinal cord stimulation, and intrathecal drug therapies have been used to treat various neuropathic pain syndromes.

  16. Influence of the Accuracy of Angiography-Based Reconstructions on Velocity and Wall Shear Stress Computations in Coronary Bifurcations: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Jelle T C Schrauwen

    Full Text Available Wall shear stress (WSS plays a key role in the onset and progression of atherosclerosis in human coronary arteries. Especially sites with low and oscillating WSS near bifurcations have a higher propensity to develop atherosclerosis. WSS computations in coronary bifurcations can be performed in angiography-based 3D reconstructions. It is essential to evaluate how reconstruction errors influence WSS computations in mildly-diseased coronary bifurcations. In mildly-diseased lesions WSS could potentially provide more insight in plaque progression.Four Plexiglas phantom models of coronary bifurcations were imaged with bi-plane angiography. The lumens were segmented by two clinically experienced readers. Based on the segmentations 3D models were generated. This resulted in three models per phantom: one gold-standard from the phantom model itself, and one from each reader. Steady-state and transient simulations were performed with computational fluid dynamics to compute the WSS. A similarity index and a noninferiority test were used to compare the WSS in the phantoms and their reconstructions. The margin for this test was based on the resolution constraints of angiography.The reconstruction errors were similar to previously reported data; in seven out of eight reconstructions less than 0.10 mm. WSS in the regions proximal and far distal of the stenosis showed a good agreement. However, the low WSS areas directly distal of the stenosis showed some disagreement between the phantoms and the readers. This was due to small deviations in the reconstruction of the stenosis that caused differences in the resulting jet, and consequently the size and location of the low WSS area.This study showed that WSS can accurately be computed within angiography-based 3D reconstructions of coronary arteries with early stage atherosclerosis. Qualitatively, there was a good agreement between the phantoms and the readers. Quantitatively, the low WSS regions directly distal to

  17. Generation of realistic virtual nodules based on three-dimensional spatial resolution in lung computed tomography: A pilot phantom study.

    Science.gov (United States)

    Narita, Akihiro; Ohkubo, Masaki; Murao, Kohei; Matsumoto, Toru; Wada, Shinichi

    2017-10-01

    The aim of this feasibility study using phantoms was to propose a novel method for obtaining computer-generated realistic virtual nodules in lung computed tomography (CT). In the proposed methodology, pulmonary nodule images obtained with a CT scanner are deconvolved with the point spread function (PSF) in the scan plane and slice sensitivity profile (SSP) measured for the scanner; the resultant images are referred to as nodule-like object functions. Next, by convolving the nodule-like object function with the PSF and SSP of another (target) scanner, the virtual nodule can be generated so that it has the characteristics of the spatial resolution of the target scanner. To validate the methodology, the authors applied physical nodules of 5-, 7- and 10-mm-diameter (uniform spheres) included in a commercial CT test phantom. The nodule-like object functions were calculated from the sphere images obtained with two scanners (Scanner A and Scanner B); these functions were referred to as nodule-like object functions A and B, respectively. From these, virtual nodules were generated based on the spatial resolution of another scanner (Scanner C). By investigating the agreement of the virtual nodules generated from the nodule-like object functions A and B, the equivalence of the nodule-like object functions obtained from different scanners could be assessed. In addition, these virtual nodules were compared with the real (true) sphere images obtained with Scanner C. As a practical validation, five types of laboratory-made physical nodules with various complicated shapes and heterogeneous densities, similar to real lesions, were used. The nodule-like object functions were calculated from the images of these laboratory-made nodules obtained with Scanner A. From them, virtual nodules were generated based on the spatial resolution of Scanner C and compared with the real images of laboratory-made nodules obtained with Scanner C. Good agreement of the virtual nodules generated from

  18. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Matsunobu, Y; Shiotsuki, K [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Morishita, J [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, JP (Japan)

    2015-06-15

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body.

  19. Comparison of axial, coronal, and primary 3D review in MDCT colonography for the detection of small polyps: a phantom study

    NARCIS (Netherlands)

    Mang, Thomas; Schaefer-Prokop, Cornelia; Schima, Wolfgang; Maier, Andrea; Schober, Ewald; Mueller-Mang, Christina; Weber, Michael; Prokop, Mathias

    2009-01-01

    The purpose of this phantom study is to compare the influence of the reading technique (axial images alone in comparison to 3D endoluminal, coronal, and combined 2D/3D review methods) on the sensitivity and inter-reader variability with MDCT colonography for the detection of small colonic polyps. An

  20. Capsaicin 8% patch treatment for amputation stump and phantom limb pain: a clinical and functional MRI study

    National Research Council Canada - National Science Library

    Privitera R; Birch R; Sinisi M; Mihaylov IR; Leech R; Anand P

    2017-01-01

    ...% patch in reducing chronic amputation stump and phantom limb pain, associated hypersensitivity with quantitative sensory testing, and changes in brain cortical maps using functional MRI (fMRI) scans. Methods: A capsaicin 8% patch (Qutenza...

  1. Real-time Classification of Non-Weight Bearing Lower-Limb Movements Using EMG to Facilitate Phantom Motor Execution: Engineering and Case Study Application on Phantom Limb Pain

    Science.gov (United States)

    Lendaro, Eva; Mastinu, Enzo; Håkansson, Bo; Ortiz-Catalan, Max

    2017-01-01

    Phantom motor execution (PME), facilitated by myoelectric pattern recognition (MPR) and virtual reality (VR), is positioned to be a viable option to treat phantom limb pain (PLP). A recent clinical trial using PME on upper-limb amputees with chronic intractable PLP yielded promising results. However, further work in the area of signal acquisition is needed if such technology is to be used on subjects with lower-limb amputation. We propose two alternative electrode configurations to conventional, bipolar, targeted recordings for acquiring surface electromyography. We evaluated their performance in a real-time MPR task for non-weight-bearing, lower-limb movements. We found that monopolar recordings using a circumferential electrode of conductive fabric, performed similarly to classical bipolar recordings, but were easier to use in a clinical setting. In addition, we present the first case study of a lower-limb amputee with chronic, intractable PLP treated with PME. The patient’s Pain Rating Index dropped by 22 points (from 32 to 10, 68%) after 23 PME sessions. These results represent a methodological advancement and a positive proof-of-concept of PME in lower limbs. Further work remains to be conducted for a high-evidence level clinical validation of PME as a treatment of PLP in lower-limb amputees. PMID:28955294

  2. Real-time Classification of Non-Weight Bearing Lower-Limb Movements Using EMG to Facilitate Phantom Motor Execution: Engineering and Case Study Application on Phantom Limb Pain.

    Science.gov (United States)

    Lendaro, Eva; Mastinu, Enzo; Håkansson, Bo; Ortiz-Catalan, Max

    2017-01-01

    Phantom motor execution (PME), facilitated by myoelectric pattern recognition (MPR) and virtual reality (VR), is positioned to be a viable option to treat phantom limb pain (PLP). A recent clinical trial using PME on upper-limb amputees with chronic intractable PLP yielded promising results. However, further work in the area of signal acquisition is needed if such technology is to be used on subjects with lower-limb amputation. We propose two alternative electrode configurations to conventional, bipolar, targeted recordings for acquiring surface electromyography. We evaluated their performance in a real-time MPR task for non-weight-bearing, lower-limb movements. We found that monopolar recordings using a circumferential electrode of conductive fabric, performed similarly to classical bipolar recordings, but were easier to use in a clinical setting. In addition, we present the first case study of a lower-limb amputee with chronic, intractable PLP treated with PME. The patient's Pain Rating Index dropped by 22 points (from 32 to 10, 68%) after 23 PME sessions. These results represent a methodological advancement and a positive proof-of-concept of PME in lower limbs. Further work remains to be conducted for a high-evidence level clinical validation of PME as a treatment of PLP in lower-limb amputees.

  3. Real-time Classification of Non-Weight Bearing Lower-Limb Movements Using EMG to Facilitate Phantom Motor Execution: Engineering and Case Study Application on Phantom Limb Pain

    Directory of Open Access Journals (Sweden)

    Eva Lendaro

    2017-09-01

    Full Text Available Phantom motor execution (PME, facilitated by myoelectric pattern recognition (MPR and virtual reality (VR, is positioned to be a viable option to treat phantom limb pain (PLP. A recent clinical trial using PME on upper-limb amputees with chronic intractable PLP yielded promising results. However, further work in the area of signal acquisition is needed if such technology is to be used on subjects with lower-limb amputation. We propose two alternative electrode configurations to conventional, bipolar, targeted recordings for acquiring surface electromyography. We evaluated their performance in a real-time MPR task for non-weight-bearing, lower-limb movements. We found that monopolar recordings using a circumferential electrode of conductive fabric, performed similarly to classical bipolar recordings, but were easier to use in a clinical setting. In addition, we present the first case study of a lower-limb amputee with chronic, intractable PLP treated with PME. The patient’s Pain Rating Index dropped by 22 points (from 32 to 10, 68% after 23 PME sessions. These results represent a methodological advancement and a positive proof-of-concept of PME in lower limbs. Further work remains to be conducted for a high-evidence level clinical validation of PME as a treatment of PLP in lower-limb amputees.

  4. Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v.

    Science.gov (United States)

    Lim, Kyungjae; Kwon, Heejin; Cho, Jinhan; Oh, Jongyoung; Yoon, Seongkuk; Kang, Myungjin; Ha, Dongho; Lee, Jinhwa; Kang, Eunju

    2015-01-01

    The purpose of this study was to assess the image quality of a novel advanced iterative reconstruction (IR) method called as "adaptive statistical IR V" (ASIR-V) by comparing the image noise, contrast-to-noise ratio (CNR), and spatial resolution from those of filtered back projection (FBP) and adaptive statistical IR (ASIR) on computed tomography (CT) phantom image. We performed CT scans at 5 different tube currents (50, 70, 100, 150, and 200 mA) using 3 types of CT phantoms. Scanned images were subsequently reconstructed in 7 different scan settings, such as FBP, and 3 levels of ASIR and ASIR-V (30%, 50%, and 70%). The image noise was measured in the first study using body phantom. The CNR was measured in the second study using contrast phantom and the spatial resolutions were measured in the third study using a high-resolution phantom. We compared the image noise, CNR, and spatial resolution among the 7 reconstructed image scan settings to determine whether noise reduction, high CNR, and high spatial resolution could be achieved at ASIR-V. At quantitative analysis of the first and second studies, it showed that the images reconstructed using ASIR-V had reduced image noise and improved CNR compared with those of FBP and ASIR (P reconstructed using ASIR-V had significantly improved spatial resolution than those of FBP and ASIR (P ASIR-V provides a significant reduction in image noise and a significant improvement in CNR as well as spatial resolution. Therefore, this technique has the potential to reduce the radiation dose further without compromising image quality.

  5. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies.

    Science.gov (United States)

    Winant, Celeste D; Aparici, Carina Mari; Zelnik, Yuval R; Reutter, Bryan W; Sitek, Arkadiusz; Bacharach, Stephen L; Gullberg, Grant T

    2012-01-21

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic (94)Tc-methoxyisobutylisonitrile ((94)Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K(1) for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K(1). For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from (94)Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of (99m)Tc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The

  6. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    Science.gov (United States)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum

  7. Synaesthesia in phantom limbs induced with mirrors.

    Science.gov (United States)

    Ramachandran, V S; Rogers-Ramachandran, D

    1996-04-22

    Although there is a vast clinical literature on phantom limbs, there have been no experimental studies on the effects of visual input on phantom sensations. We introduce an inexpensive new device--a 'virtual reality box'--to resurrect the phantom visually to study inter-sensory effects. A mirror is placed vertically on the table so that the mirror reflection of the patient's intact had is 'superimposed' on the felt position of the phantom. We used this procedure on ten patients and found the following results. 1. In six patients, when the normal hand was moved, so that the phantom was perceived to move in the mirror, it was also felt to move; i.e. kinesthetic sensations emerged in the phantom. In D.S. this effect occurred even though he had never experienced any movements in the phantom for ten years before we tested him. He found the return of sensations very enjoyable. 2. Repeated practice led to a permanent 'disappearance' of the phantom arm in patient D.S. and the hand became telescoped into the stump near the shoulder. 3. Using an optical trick, impossible postures--e.g. extreme hyperextension of the fingers--could be induced visually in the phantom. In one case this was felt as a transient 'painful tug' in the phantom. 4. Five patients experienced involuntary painful 'clenching spasms' in the phantom hand and in four of them the spasms were relieved when the mirror was used to facilitate 'opening' of the phantom hand; opening was not possible without the mirror. 5. In three patients, touching the normal hand evoked precisely localized touch sensations in the phantom. Interestingly, the referral was especially pronounced when the patients actually 'saw' their phantom being touched in the mirror. Indeed, in a fourth patient (R.L.) the referral occurred only if he saw his phantom being touched: a curious form of synaesthesia. These experiments lend themselves readily to imaging studies using PET and fMRI. Taken collectively, they suggest that there is a

  8. Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Jason M.; Rani, Sudheer D.; Li, Xia; Whisenant, Jennifer G.; Abramson, Richard G. [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 and Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37232 (United States); Arlinghaus, Lori R. [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 (United States); Lee, Tzu-Cheng [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); MacDonald, Lawrence R.; Partridge, Savannah C. [Department of Radiology, University of Washington, Seattle, Washington 98195 (United States); Kang, Hakmook [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 and Department of Biostatistics, Vanderbilt University, Nashville, Tennessee 37232 (United States); Linden, Hannah M. [Department of Medical Oncology, University of Washington, Seattle, Washington 98195 (United States); Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, Washington 98195 (United States); Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Physics, University of Washington, Seattle, Washington 98195 (United States); Department of Electrical Engineering, University of Washington, Seattle, Washington 98195 (United States); Yankeelov, Thomas E., E-mail: thomas.yankeelov@vanderbilt.edu [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Physics, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Cancer Biology, Vanderbilt University, Nashville, Tennessee 37232 (United States)

    2015-07-15

    Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were

  9. Creation of 3D digital anthropomorphic phantoms which model actual patient non-rigid body motion as determined from MRI and position tracking studies of volunteers

    Science.gov (United States)

    Connolly, C. M.; Konik, A.; Dasari, P. K. R.; Segars, P.; Zheng, S.; Johnson, K. L.; Dey, J.; King, M. A.

    2011-03-01

    Patient motion can cause artifacts, which can lead to difficulty in interpretation. The purpose of this study is to create 3D digital anthropomorphic phantoms which model the location of the structures of the chest and upper abdomen of human volunteers undergoing a series of clinically relevant motions. The 3D anatomy is modeled using the XCAT phantom and based on MRI studies. The NURBS surfaces of the XCAT are interactively adapted to fit the MRI studies. A detailed XCAT phantom is first developed from an EKG triggered Navigator acquisition composed of sagittal slices with a 3 x 3 x 3 mm voxel dimension. Rigid body motion states are then acquired at breath-hold as sagittal slices partially covering the thorax, centered on the heart, with 9 mm gaps between them. For non-rigid body motion requiring greater sampling, modified Navigator sequences covering the entire thorax with 3 mm gaps between slices are obtained. The structures of the initial XCAT are then adapted to fit these different motion states. Simultaneous to MRI imaging the positions of multiple reflective markers on stretchy bands about the volunteer's chest and abdomen are optically tracked in 3D via stereo imaging. These phantoms with combined position tracking will be used to investigate both imaging-data-driven and motion-tracking strategies to estimate and correct for patient motion. Our initial application will be to cardiacperfusion SPECT imaging where the XCAT phantoms will be used to create patient activity and attenuation distributions for each volunteer with corresponding motion tracking data from the markers on the body-surface. Monte Carlo methods will then be used to simulate SPECT acquisitions, which will be used to evaluate various motion estimation and correction strategies.

  10. The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study.

    Science.gov (United States)

    Tellmann, L; Quick, H H; Bockisch, A; Herzog, H; Beyer, T

    2011-05-01

    The use of magnetic resonance (MR) radiofrequency (RF) surface coils is a prerequisite for high-quality positron emission tomography (PET)/MR imaging. In lack of in-gantry transmission (TX) sources, the exact position of the RF coils is unknown in PET/MR, and may, therefore, lead to false attenuation correction (AC) of the emission (EM) data. The authors assess lesion and background quantification in AC-PET by mimicking different PET/MR imaging situations using a whole-body (WB) PET-only tomograph. Phantom experiments were performed on a PET tomograph with 68 Ge-rod TX sources. First, a 15-cm plastic cylinder was filled uniformly with [18F]-FDG to simulate a head study. Second, a NEMA NU-2001 image quality phantom (35 x 25 x 25 cm3) was filled uniformly with [18F]-FDG to simulate torso imaging. The phantom contained six lesions (10-38 mm diameter, lesion-to-background ratio 6:1) centred around a 5 cm diameter lung insert. EM and TX measurements were acquired with and without MR head (cylinder) and surface (NU-2001 phantom) RF coils in place. The following imaging situations were mimicked in both head and torso phantom studies: (1) PET scan without MR coils in EM and TX for reference, (2) PET scan with coils in both EM and TX, and (3) PET scan with coils in EM but without coils in TX. Two more set-ups were performed for the torso phantom: (4) PET scan with coils in EM only and phantom shifted slightly compared to (3), and (5) PET scan with coils in EM and TX following local displacement of the surface coils. PET EM data (1)-(4) were corrected for attenuation and scatter using cold TX data. Imaging situations (1)-(3) were repeated with the cylinder phantom and head coil in a combined PET/MR prototype system employing template-based AC. Head phantom: In case the MR head coils were not accounted for during AC (3), central and peripheral background activity concentration was underestimated by 13%-19% when compared to the reference setup (1). The effects of MR coil

  11. The neural basis of phantom limb pain.

    Science.gov (United States)

    Flor, Herta; Diers, Martin; Andoh, Jamila

    2013-07-01

    A recent study suggests that brain changes in amputees may be pain-induced, questioning maladaptive plasticity as a neural basis of phantom pain. These findings add valuable information on cortical reorganization after amputation. We suggest further lines of research to clarify the mechanisms that underlie phantom pain. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Accuracy analysis of line-based registration for image guided neurosurgery at different operating areas - a phantom study.

    Science.gov (United States)

    Ji, Dafeng; Dong, Yuan; Wang, Manning; Song, Zhijian

    2017-12-01

    Space registration is the primary function of neuronavigation systems. According to the stage of the operation, the registration could be classified as rigid and non-rigid methods. Scientists have proposed three types of rigid registration methods: point-based registration (PBR), line-based registration (LBR), and surface-based registration (SBR). PBR has been widely used in clinical applications. Recently, LBR was proposed as a new spacing registration method. However, the range and accuracy of LBR are still not defined for clinical applications. In this paper, LBR has been evaluated directly with target registration error (TRE) in different operating areas: sphenoid-frontal, parietal-temporal, and occipital areas. We used two head phantoms: elastic and rigid phantoms. After scanning with computerized tomography (CT), the difference between the TRE of the elastic and rigid phantom had been evaluated based on LBR method. Then, LBR had been employed at the rigid phantom using different line patterns: single (100 points), double (200 points), triple (300 points), and quartic lines (400 points). TRE were directly measured on the phantom. Then, t-tests were applied to evaluate the difference between the TRE of LBR of both the phantoms and line patterns. Results indicate that there is no statistical difference in TRE between the phantoms. TRE were reduced to less than 3 mm after the use of double lines which was significantly less than those after the use of single lines. Except for sphenoid tumor, the other operating areas showed statistical differences in TRE between double and triple lines. Except for temporal tumor, the differences between the TRE of triple and quartic lines are not significant.

  13. Reproducibility of trabecular bone score with different scan modes using dual-energy X-ray absorptiometry: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Bandirali, Michele; Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Di Leo, Giovanni [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Pastor Lopez, Maria Juana; Ulivieri, Fabio M. [Servizio di Medicina Nucleare, Ospedale Maggiore, Mineralometria Ossea Computerizzata e Ambulatorio Malattie Metabolismo Minerale e Osseo, Milano (Italy); Mai, Alessandro [Universita degli Studi di Milano, Tecniche di Radiologia Medica, per Immagini e Radioterapia, Milano (Italy); Sardanelli, Francesco [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy)

    2014-08-12

    The trabecular bone score (TBS) accounts for the bone microarchitecture and is calculated on dual-energy X-ray absorptiometry (DXA). We estimated the reproducibility of the TBS using different scan modes compared to the reproducibility bone mineral density (BMD). A spine phantom was used with a Hologic QDR-Discovery A densitometer. For each scan mode [fast array, array, high definition (HD)], 25 scans were automatically performed without phantom repositioning; a further 25 scans were performed with phantom repositioning. For each scan, the TBS was obtained. The coefficient of variation (CoV) was calculated as the ratio between standard deviation and mean; percent least significant change (LSC%) as 2.8 x CoV; reproducibility as the complement to 100 % of LSC%. Differences among scan modes were assessed using ANOVA. Without phantom repositioning, the mean TBS (mm{sup -1}) was: 1.352 (fast array), 1.321 (array), and 1.360 (HD); with phantom repositioning, it was 1.345, 1.332, and 1.362, respectively. Reproducibility of the TBS without phantom repositioning was 97.7 % (fast array), 98.3 % (array), and 98.2 % (HD); with phantom repositioning, it was 97.9 %, 98.7 %, and 98.4 %, respectively. LSC% was ≤2.26 %. Differences among scan modes were all statistically significant (p ≤ 0.019). Reproducibility of BMD was 99.1 % with all scan modes, while LSC% was from 0.86 % to 0.91 %. Reproducibility error of the TBS was 2-3-fold higher than that of BMD. Although statistically significant, differences in TBS among scan modes were within the highest LSC%. Thus, the three scan modes can be considered interchangeable. (orig.)

  14. Phantom study to evaluate contrast-medium-enhanced digital subtraction mammography with a full-field indirect-detection system.

    Science.gov (United States)

    Palma, B A; Rosado-Méndez, I; Villaseñor, Y; Brandan, M E

    2010-02-01

    This phantom study simulates contrast-medium-enhanced digital subtraction mammography (CEDM) and compares subtracted image quality and total mean glandular dose for two alternative spectral combinations available in a GE Senographe DS mammography unit. The first choice takes advantage of large iodine attenuation at low photon energies and uses traditionally available spectra (anode/filter combinations Mo/Mo at 25 kV and Rh/Rh at 40 kV, "Mo25-Rh40"). The second choice, selected from a previous analytical optimization, includes harder spectra obtained by adding external filtration to traditional beams (Rh/Rh at 34 kV and Rh/Rh+5 mm of Al at 45 kV, "Rh34-Rh45H"). Individual images of a custom-made phantom containing tubes of various diameters filled with water- or iodine-based contrast agent were acquired with both spectral combinations. The total breast entrance air kerma, considering subtraction of two images, was limited to 8.76 mGy (1 R). The results were compared to predictions obtained through an analytical formalism that assumes noise of stochastic origin. Individual images were evaluated and subtracted under five combinations of temporal and dual-energy modalities. Signal variance analysis in individual raw images showed important contributions of nonstochastic origin, associated with the software applied to raw images, the curved geometry, and strong attenuation of the phantom cylindrical iodine-filled tubes, causing experimental SNR to vary from 2.2 to 0.8 times the predictions from low to high values of SNR. Iodine contrast in the subtracted images was found to be mainly defined by the spectra, independent of exposure, and linearly dependent on the iodine mass thickness. The highest contrast was obtained with the combined dual-energy temporal subtraction with Rh34-Rh45H, its value was 7% larger than the highest value measured with Mo25-Rh40. As expected, temporal modalities (single and dual energy, any spectral choice) led to higher contrast

  15. Effect of Scanning and Reconstruction Parameters on Three Dimensional Volume and CT Value Measurement of Pulmonary Nodules: A Phantom Study

    Directory of Open Access Journals (Sweden)

    Datong SU

    2017-08-01

    Full Text Available Background and objective The computed tomography (CT follow-up of indeterminate pulmonary nodules aiming to evaluate the change of the volume and CT value is the common strategy in clinic. The CT dose needs to considered on serious CT scans in addition to the measurement accuracy. The purpose of this study is to quantify the precision of pulmonary nodule volumetric measurement and CT value measurement with various tube currents and reconstruction algorithms in a phantom study with dual-energy CT. Methods A chest phantom containing 9 artificial spherical solid nodules with known diameter (D=2.5 mm, 5 mm, 10 mm and density (-100 HU, 60 HU and 100 HU was scanned using a 64-row detector CT canner at 120 Kilovolt & various currents (10 mA, 20 mA, 50 mA, 80 mA,100 mA, 150 mA and 350 mA. Raw data were reconstructed with filtered back projection and three levels of adaptive statistical iterative reconstruction algorithm (FBP, ASIR; 30%, 50% and 80%. Automatic volumetric measurements were performed using commercially available software. The relative volume error (RVE and the absolute attenuation error (AAE between the software measures and the reference-standard were calculated. Analyses of the variance were performed to evaluate the effect of reconstruction methods, different scan parameters, nodule size and attenuation on the RPE. Results The software substantially overestimated the very small (D=2.5 mm nodule's volume [mean RVE: (100.8%±28%] and underestimated it attenuation [mean AAE: (-756±80 HU]. The mean RVEs of nodule with diameter as 5 mm and 10 mm were small [(-0.9%±1.1% vs (0.9%±1.4%], however, the mean AAEs [(-243±26 HU vs (-129±7 HU] were large. The ANOVA analysis for repeated measurements showed that different tube current and reconstruction algorithm had no significant effect on the volumetric measurements for nodules with diameter of 5 mm and 10 mm (F=5.60, P=0.10 vs F=11.13, P=0.08, but significant effects on the measurement of CT

  16. Dual-frequency ultrasound focal therapy for MRI-guided transurethral treatment of the prostate: Study in gel phantom

    Science.gov (United States)

    N'Djin, W. Apoutou; Mougenot, Charles; Kobelevskiy, Ilya; Ramsay, Elizabeth; Bronskill, Michael; Chopra, Rajiv

    2012-11-01

    Ultrasound thermal therapy of localized prostate cancer offers a minimally-invasive non-ionizing alternative [1-3] to surgery and radiotherapy. MRI-controlled transurethral ultrasound prostate therapy [4-6] has previously been investigated in a pilot human feasibility study [7], by treating a small sub-volume of prostate tissue. In this study, the feasibility of transurethral dual-frequency ultrasound focal therapy has been investigated in gel phantom. A database of pelvic anatomical models of human prostate cancer patients have been created using MR clinical images. The largest prostate boundary (47 cm3) was used to fabricate an anatomical gel phantom which included various MR characteristics to mimic prostate tissues, 4 localized tumors and surrounding prostate tissues. A 9-element transurethral ultrasound applicator working in dual-frequency mode (f = 4.6/14.5 MHz) was evaluated to heat: (i) the entire prostate volume (Full prostate treatment strategy), (ii) a prostate region restricted to tumors (Focal therapy). Acoustic power of each element and rotation rate of the device were adjusted in realtime based on MR-thermometry feedback control (nine thermal slices updated every 6.2s). Experiments have been performed using dual-frequency ultrasound exposures (surface Pmax: 20W.cm-2). (i) For full prostate heating, 7 elements of the device were used to cover the entire prostate length. The heating process was completed within 35 min. Ultrasound exposures at the fundamental frequency allowed full heating of the largest prostate radii (>18 mm), while exposures at the 3rd harmonic ensured homogeneous treatment of the smallest radii. Undertreated and overtreated regions represented respectively 2% and 17% of the prostate volume. (ii) For focal therapy, the target region was optimized to maintain safe regions in the prostate and to cover all tumor-mimics. Only 5 ultrasound elements were used to treat successfully all tumor-mimics within 26 min. Undertreated and

  17. Synthetic breast phantoms from patient based eigenbreasts.

    Science.gov (United States)

    Sturgeon, Gregory M; Park, Subok; Segars, William Paul; Lo, Joseph Y

    2017-12-01

    The limited number of 3D patient-based breast phantoms available could be augmented by synthetic breast phantoms in order to facilitate virtual clinical trials (VCTs) using model observers for breast imaging optimization and evaluation. These synthetic breast phantoms were developed using Principal Component Analysis (PCA) to reduce the number of dimensions needed to describe a training set of images. PCA decomposed a training set of M breast CT volumes (with millions of voxels each) into an M-1-dimensional space of eigenvectors, which we call eigenbreasts. Each of the training breast phantoms was compactly represented by the mean image plus a weighted sum of eigenbreasts. The distribution of weights observed from training was then sampled to create new synthesized breast phantoms. The resulting synthesized breast phantoms demonstrated a high degree of realism, as supported by an observer study. Two out of three experienced physicist observers were unable to distinguish between the synthesized breast phantoms and the patient-based phantoms. The fibroglandular density and noise power law exponent of the synthesized breast phantoms agreed well with the training data. Our method extends our series of digital breast phantoms based on breast CT data, providing the capability to generate new, statistically varying ensembles consisting of tens of thousands of virtual subjects. This work represents an important step toward conducting future virtual trials for task-based assessment of breast imaging, where it is vital to have a large ensemble of realistic phantoms for statistical power as well as clinical relevance. © 2017 American Association of Physicists in Medicine.

  18. Contrast-enhanced near-infrared laser mammography with a prototype breast scanner: feasibility study with tissue phantoms and preliminary results of imaging experimental tumors.

    Science.gov (United States)

    Boehm, T; Hochmuth, A; Malich, A; Reichenbach, J R; Fleck, M; Kaiser, W A

    2001-10-01

    Near-infrared (NIR) optical mammography without contrast has a low specificity. The application of optical contrast medium may improve the performance. The concentration-dependent detectability of a new NIR contrast medium was determined with a prototype optical breast scanner. In vivo imaging of experimental tumors was performed. The NIR contrast agent NIR96010 is a newly synthesized, hydrophilic contrast agent for NIR mammography. A concentration-dependent contrast resolution was determined for tissue phantoms consisting of whole milk powder and gelatin. A central part of the phantoms measuring 2 x 2 cm2 without contrast was replaced with phantom material containing 1 micromol/L to 25 nmol/L NIR96010. The composite phantoms were measured with a prototype NIR breast scanner with lasers of lambda1 = 785 nm and lambda2 = 850 nm wavelength. Intensity profiles and standard deviations of the transmission signal in areas with and without contrast were determined by linear fit procedures. Signal-to-noise ratios and spatial resolution as a function of contrast concentration were determined. Near-infrared imaging of five tumor-bearing SCID mice (MX1 breast adenocarcinoma, tumor diameter 5-10 mm) was performed before and after intravenous application of 2 micromol/kg NIR96010. Spectrometry showed an absorption maximum of the contrast agent at 755 nm. No spectral shifts occurred in protein-containing solution. Signal-to-noise ratio in the transmission intensity profiles ranged from 1.1 at 25 nmol/L contrast to 28 at 1 micromol/L. At concentrations <40 nmol/L, no differentiation from the background was possible. The transitional area between the contrast-free edge of the phantom and the central contrast-containing part appeared in the profiles as a steep increase with a width of 4.2 +/- 1.8 mm. The experimental tumors were detectable in nonenhanced images as well as contrast-enhanced images, with better delineation after contrast administration. In postcontrast absorption

  19. [Capsaicin 8 % cutaneous patches for phantom limb pain. Results from everyday practice (non-interventional study)].

    Science.gov (United States)

    Kern, K-U; Baust, H; Hofmann, W; Holzmüller, R; Maihöfner, C; Heskamp, M-L

    2014-08-01

    Post amputation pain presents a challenge for pain physicians and is often detrimental to the patient's quality of life. A prospective 12-week non-interventional study (NIS) was conducted in Germany to obtain data on the effectiveness and safety of capsaicin 8 % cutaneous patches from real life use in patients with peripheral neuropathic pain. For the first time in a subgroup of amputees data on post amputation pain were collected. This article presents the results for patients who suffered from phantom limb pain (PLP), stump pain (SP) and combined phantom limb/stump pain (PLP/SP). The analyses included 21 patients with post amputation pain (PLP: n = 10, SP: n = 4, PLP/SP: n = 7). The mean duration of pain (± standard deviation) was 12.8 ± 13.0 years for PLP, 23.1 ± 29.9 years for SP and 11.0 ± 15.8 years for PLP/SP. A single treatment with capsaicin 8 % cutaneous patches significantly reduced the average pain intensity over the observational period of 12 weeks. The mean numeric pain rating scale (NPRS) baseline score changed by - 2.4 for PLP with a standard error of the mean (SEM) of 0.4 (median: - 2.9, Q1: - 3.5, Q3: - 1.0), - 1.7 for SP (SEM: 0.8, median: - 1.1, Q1: - 2.9, Q3: - 0.5) and - 1.5 for PLP/SP (SEM: 0.6, median: - 2.0, Q1: - 2.3, Q3: 0) during weeks 1-12. The 30 % responder rates (i.e. ≥ 30 % reduction in pain, day 7/14 to week 12) were 70.0 % (PLP), 50.0 % (SP) and 28.6 % (PLP/SP). PLP and PLP/SP patients in particular, benefited from improvements in pain attacks, sleep duration and sleep quality and one patient (PLP/SP) reported an adverse drug reaction (increase of pain). Physicians rated the tolerability of the patch as very good or good in 90.5 % of patients. A poor tolerability was stated for none of the 21 amputees. Of the patients 80 % for PLP and 50 % for both SP and PLP/SP expressed the wish to receive retreatment with capsaicin 8 % patches. Capsaicin 8

  20. Estimating head and neck tissue dose from x-ray scatter to physicians performing x-ray guided cardiovascular procedures: a phantom study.

    Science.gov (United States)

    Fetterly, Kenneth A; Schueler, Beth A; Grams, Michael P; Sturchio, Glenn M

    2017-03-20

    Physicians performing x-ray guided interventional procedures have a keen interest in radiation safety. Radiation dose to tissues and organs of the head and neck are of particular interest because they are not routinely protected by wearable radiation safety devices. This study was conducted to facilitate estimation of radiation dose to tissues of the head and neck of interventional physicians based on the dose recorded by a personal dosimeter worn on the left collar. Scatter beam qualities maximum energy and HVL were measured for 40 scatter beams emitting from an anthropomorphic patient phantom. Variables of the scatter beams included scatter angle (35° and 90°), primary beam peak tube potential (60, 80, 100, and 120 kVp), and 5 Cu spectral filter thicknesses (0-0.9 mm). Four reference scatter beam qualities were selected to represent the range of scatter beams realized in a typical practice. A general radiographic x-ray tube was tuned to produce scatter-equivalent radiographic beams and used to simultaneously expose the head and neck of an anthropomorphic operator phantom and radiochromic film. The geometric relationship between the x-ray source of the scatter-equivalent beams and the operator phantom was set to mimic that between a patient and physician performing an invasive cardiovascular procedure. Dose to the exterior surface of the operator phantom was measured with both 3 × 3 cm2 pieces of film and personal dosimeters positioned at the location of the left collar. All films were scanned with a calibrated flatbed scanner, which converted the film's reflective density to dose. Films from the transverse planes of the operator phantom provided 2D maps of the dose distribution within the phantom. These dose maps were normalized by the dose at the left collar, providing 2D percent of left collar dose (LCD) maps. The percent LCD maps were overlain with bony anatomy CT images of the operator phantom and estimates of percent LCD to the left, right and whole

  1. Verifying 4D gated radiotherapy using time-integrated electronic portal imaging: a phantom and clinical study

    Directory of Open Access Journals (Sweden)

    Slotman Ben J

    2007-08-01

    Full Text Available Abstract Background Respiration-gated radiotherapy (RGRT can decrease treatment toxicity by allowing for smaller treatment volumes for mobile tumors. RGRT is commonly performed using external surrogates of tumor motion. We describe the use of time-integrated electronic portal imaging (TI-EPI to verify the position of internal structures during RGRT delivery Methods TI-EPI portals were generated by continuously collecting exit dose data (aSi500 EPID, Portal vision, Varian Medical Systems when a respiratory motion phantom was irradiated during expiration, inspiration and free breathing phases. RGRT was delivered using the Varian RPM system, and grey value profile plots over a fixed trajectory were used to study object positions. Time-related positional information was derived by subtracting grey values from TI-EPI portals sharing the pixel matrix. TI-EPI portals were also collected in 2 patients undergoing RPM-triggered RGRT for a lung and hepatic tumor (with fiducial markers, and corresponding planning 4-dimensional CT (4DCT scans were analyzed for motion amplitude. Results Integral grey values of phantom TI-EPI portals correlated well with mean object position in all respiratory phases. Cranio-caudal motion of internal structures ranged from 17.5–20.0 mm on planning 4DCT scans. TI-EPI of bronchial images reproduced with a mean value of 5.3 mm (1 SD 3.0 mm located cranial to planned position. Mean hepatic fiducial markers reproduced with 3.2 mm (SD 2.2 mm caudal to planned position. After bony alignment to exclude set-up errors, mean displacement in the two structures was 2.8 mm and 1.4 mm, respectively, and corresponding reproducibility in anatomy improved to 1.6 mm (1 SD. Conclusion TI-EPI appears to be a promising method for verifying delivery of RGRT. The RPM system was a good indirect surrogate of internal anatomy, but use of TI-EPI allowed for a direct link between anatomy and breathing patterns.

  2. Quantifying the optical properties and chromophore concentrations of turbid media using polarization sensitive hyperspectral imaging: optical phantom studies

    Science.gov (United States)

    Vasefi, Fartash; Saager, Rolf; Durkin, Anthony J.; MacKinnon, Nicholas; Gussakovsky, Eugene; Chave, Robert; Farkas, Daniel L.

    2013-02-01

    We present a polarization-sensitive hyperspectral imaging system (SkinSpect) that employs a spectrally-programmable light source in the visible and NIR domains. Multiple tissue-mimicking phantoms were fabricated to mimic the optical properties of normal skin as well as pigmented light and dark moles. The phantoms consist of titanium dioxide and a mixture of coffee, red food dye, and naphthol green as the scattering and the three absorptive agents in a polydimethylsiloxane (PDMS) base. Phantoms were produced with both smooth and rough textured surfaces and tested using Spatial Frequency Domain Imaging (SFDI) and Spatially Modulated Quantitative Spectroscopy (SMoQS) for homogeneity as well as determining absorption and scattering variance, respectively. The reflectance spectral images were also recorded using the SkinSpect research prototype; the spectral signatures of the phantoms were calculated using a two-flux single-layer Kubelka-Munk model and non-negative least square fitting routine was applied to extract the relative concentrations of the individual phantom components.

  3. Monte Carlo simulation studies on scintillation detectors and image reconstruction of brain-phantom tumors in TOFPET

    Directory of Open Access Journals (Sweden)

    Mondal Nagendra

    2009-01-01

    Full Text Available This study presents Monte Carlo Simulation (MCS results of detection efficiencies, spatial resolutions and resolving powers of a time-of-flight (TOF PET detector systems. Cerium activated Lutetium Oxyorthosilicate (Lu 2 SiO 5 : Ce in short LSO, Barium Fluoride (BaF 2 and BriLanCe 380 (Cerium doped Lanthanum tri-Bromide, in short LaBr 3 scintillation crystals are studied in view of their good time and energy resolutions and shorter decay times. The results of MCS based on GEANT show that spatial resolution, detection efficiency and resolving power of LSO are better than those of BaF 2 and LaBr 3 , although it possesses inferior time and energy resolutions. Instead of the conventional position reconstruction method, newly established image reconstruction (talked about in the previous work method is applied to produce high-tech images. Validation is a momentous step to ensure that this imaging method fulfills all purposes of motivation discussed by reconstructing images of two tumors in a brain phantom.

  4. A hydrophobic gel phantom for study of thermochemical ablation: initial results using a weak acid and weak base.

    Science.gov (United States)

    Misselt, Andrew J; Edelman, Theresa L; Choi, Jeung H; Bischof, John C; Cressman, Erik N K

    2009-10-01

    To develop a model for study of exothermic chemical reactions potentially useful for tissue ablation. Seven gelatins ranging from 0.5% to 30% wt/vol with and without 15% or 30% caps and several commercial gels were evaluated. Baseline temperature measurements were taken. Acetic acid and ammonium hydroxide were sequentially injected over periods of 10-15 seconds in 1-mL aliquots, forming a discrete aqueous reaction chamber. Congo red pH indicator was included to assess the reaction. A thermocouple allowed data collection at completion of injection and every 15 seconds for 5 minutes. Injections were performed in triplicate, and average temperatures for each time point were reported. Gelatins fractured or refluxed even at the lowest concentrations tested. Most commercial gels proved too viscous and likewise led to reflux along the needle tract. A mineral oil-based gel was selected because of its ability to form a chamber without reflux or fracture and its clear colorless character, hydrophobic nature, chemical stability, viscosity, specific gravity, and cost. Temperatures during the first 60 seconds of the neutralization reaction showed an immediate increase that correlated well with concentration. The oil gel phantom is a safe, useful, readily available, inexpensive model to study mixing behaviors and maximum heating potentials for reactions that may prove useful in thermochemical tissue ablation for oncologic interventions. Measurable temperature changes occurred even at the lowest concentrations, and higher concentrations produced a greater release of heat energy.

  5. Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study

    Science.gov (United States)

    Tan, Sovira; Yao, Jianhua; Yao, Lawrence; Ward, Michael M.

    2012-07-01

    Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (qualitative human judgment) may compromise sensitivity. With newly available treatments, more precise measures of syndesmophytes are needed to determine whether treatment can slow rates of syndesmophyte growth. We previously presented a computer algorithm measuring syndesmophyte volumes and heights in the 3D space of CT scans. In this study, we present improvements to the original algorithm and evaluate the gain in precision as applied to an anthropomorphic vertebral phantom and patients. Each patient was scanned twice in one day, thus providing two syndesmophyte volume and height measures. The difference between those two measures (ideally zero) determines our algorithm's precision. The technical improvements to the algorithm decreased the mean volume difference (standard deviation) between scans from 3.01% (2.83%) to 1.31% (0.95%) and the mean height difference between scans from 3.16% (2.99%) to 1.56% (1.13%). The high precision of the improved algorithm holds promise for application to longitudinal clinical studies.

  6. SU-D-209-06: Study On the Dose Conversion Coefficients in Pediatric Radiography with the Development of Children Voxel Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Q [Institute of Radiation Medicine Fudan University, Shanghai (China); Shanghai General Hospital, Shanghai, Shanghai (China); Zhuo, W; Liu, H [Institute of Radiation Medicine Fudan University, Shanghai (China); Liu, Y; Chen, T [Shanghai General Hospital, Shanghai, Shanghai (China)

    2016-06-15

    Purpose: Conversion coefficients of organ dose normalized to entrance skin dose (ESD) are widely used to evaluate the organ doses directly using ESD without time-consuming dose measurement, this work aims to investigate the dose conversion coefficients in pediatric chest and abdomen radiography with the development of 5 years and 10 years old children voxel phantoms. Methods: After segmentation of organs and tissues from CT slice images of ATOM tissue-equivalent phantoms, a 5-year-old and a 10-year-old children computational voxel phantoms were developed for Monte Carlo simulation. The organ doses and the entrance skin dose for pediatric chest postero-anterior projection and abdominal antero-posterior projection were simulated at the same time, and then the organ dose conversion coefficients were calculated.To verify the simulated results, dose measurement was carried out with ATOM tissue-equivalent phantoms for 5 year chest radiography. Results: Simulated results and experimental results matched very well with each other, the result differences of all the organs covered in radiation field were below 16% for 5-year-old child in chest projection. I showed that the conversion coefficients of organs covered in the radiation field were much larger than organs out of the field for all the study cases, for example, the conversion coefficients of stomach, liver intestines, and pancreas are larger for abdomen radiography while conversion coefficients of lungs are larger for chest radiography. Conclusion: The voxel children phantoms were helpful to evaluate the radiation doses more accurately and efficiently. Radiation field was the essential factor that affects the organ dose, use reasonably small field should be encouraged for radiation protection. This work was supported by the National Natural Science Foundation of China(11475047)

  7. 21. Phantom pain.

    NARCIS (Netherlands)

    Wolff, A.P.; Vanduynhoven, E.; Kleef, M. van; Huygen, F.; Pope, J.E.; Mekhail, N.

    2011-01-01

    Phantom pain is pain caused by elimination or interruption of sensory nerve impulses by destroying or injuring the sensory nerve fibers after amputation or deafferentation. The reported incidence of phantom limb pain after trauma, injury or peripheral vascular diseases is 60% to 80%. Over half the

  8. In vitro metabolism and permeation studies in rat jejunum

    DEFF Research Database (Denmark)

    Gammelgaard, B; Jensen, K; Steffansen, B

    1999-01-01

    The purpose of these studies was to compare the in vitro absorption of two inorganic chromium(III) compounds: chromium chloride and chromium nitrate, with organic chromium(III)-picolinate; and to investigate if any in vitro metabolism of chromium(VI) takes place. The in vitro metabolism studies...

  9. Phantom pain : A sensitivity analysis

    NARCIS (Netherlands)

    Borsje, Susanne; Bosmans, JC; Van der Schans, CP; Geertzen, JHB; Dijkstra, PU

    2004-01-01

    Purpose : To analyse how decisions to dichotomise the frequency and impediment of phantom pain into absent and present influence the outcome of studies by performing a sensitivity analysis on an existing database. Method : Five hundred and thirty-six subjects were recruited from the database of an

  10. Realistic computerized human phantoms

    Science.gov (United States)

    Zankl, M.; Veit, R.; Petoussi, N.; Mannweiler, E.; Wittmann, A.; Drexler, G.

    1994-10-01

    To estimate the risk resulting from exposures to ionizing radiation, the organ and tissue doses should be assessed. A convenient method is the calculation of these doses using representations of the human body, called models or phantoms, together with computer codes simulating the transport of radiation in the body. Most commonly used are mathematical phantoms whose external and internal volumes are defined by simple geometric bodies. More recently, phantoms constructed from computed tomographic data of real persons were introduced as an improvement. These phantoms present advantages concerning the location and shape of the organs, in particular the hard bone and bone marrow, whose distribution can be assessed with high resolution. So far, three of these phantoms were constructed at the GSF, a fourth is under process. The construction technique is described, and some calculational results of organ doses due to external photon irradiation are presented.

  11. Shear-wave sonoelastography for assessing masseter muscle hardness in comparison with strain sonoelastography: study with phantoms and healthy volunteers.

    Science.gov (United States)

    Ariji, Yoshiko; Nakayama, Miwa; Nishiyama, Wataru; Nozawa, Michihito; Ariji, Eiichiro

    2016-01-01

    Objectives Shear-wave sonoelastography is expected to facilitate low operator dependency, high reproducibility and quantitative evaluation, whereas there are few reports on available normative values of in vivo tissue in head and neck fields. The purpose of this study was to examine the reliabilities on measuring hardness using shear-wave sonoelastography and to clarify normal values of masseter muscle hardness in healthy volunteers. Methods Phantoms with known hardness ranging from 20 to 140 kPa were scanned with shear-wave sonoelastography, and inter- and intraoperator reliabilities were examined compared with strain sonoelastography. The relationships between the actual and measured hardness were analyzed. The masseter muscle hardness in 30 healthy volunteers was measured using shear-wave sonoelastography. The inter- and intraoperator intraclass correlation coefficients were almost perfect. Strong correlations were seen between the actual and measured hardness. The mean hardness of the masseter muscles in healthy volunteers was 42.82 ± 5.56 kPa at rest and 53.36 ± 8.46 kPa during jaw clenching. The hardness measured with shear-wave sonoelastography showed high-level reliability. Shear-wave sonoelastography may be suitable for evaluation of the masseter muscles.

  12. Fractal network dimension and viscoelastic powerlaw behavior: II. An experimental study of structure-mimicking phantoms by magnetic resonance elastography

    Science.gov (United States)

    Guo, Jing; Posnansky, Oleg; Hirsch, Sebastian; Scheel, Michael; Taupitz, Matthias; Braun, Juergen; Sack, Ingolf

    2012-06-01

    The dynamics of the complex shear modulus, G*, of soft biological tissue is governed by the rigidity and topology of multiscale mechanical networks. Multifrequency elastography can measure the frequency dependence of G* in soft biological tissue, providing information about the structure of tissue networks at multiple scales. In this study, the viscoelastic properties of structure-mimicking phantoms containing tangled paper stripes embedded in agarose gel are investigated by multifrequency magnetic resonance elastography within the dynamic range of 40-120 Hz. The effective media viscoelastic properties are analyzed in terms of the storage modulus (the real part of G*), the loss modulus (the imaginary part of G*) and the viscoelastic powerlaw given by the two-parameter springpot model. Furthermore, diffusion tensor imaging is used for investigating the effect of network structures on water mobility. The following observations were made: the random paper networks with fractal dimensions between 2.481 and 2.755 had no or minor effects on the storage modulus, whereas the loss modulus was significantly increased about 2.2 kPa per fractal dimension unit (R = 0.962, P soft-tissue viscoelastic parameters. In the dynamic range of in vivo elastography, the fractal network dimension primarily correlates to the loss behavior of soft tissue as can be seen from the loss modulus or the powerlaw exponent of the springpot model. These findings represent the experimental underpinning of structure-sensitive elastography for an improved characterization of various soft-tissue diseases.

  13. Can conclusions drawn from phantom-based image noise assessments be generalized to in vivo studies for the nonlinear model-based iterative reconstruction method?

    Science.gov (United States)

    Gomez-Cardona, Daniel; Li, Ke; Hsieh, Jiang; Lubner, Meghan G; Pickhardt, Perry J; Chen, Guang-Hong

    2016-02-01

    Phantom-based objective image quality assessment methods are widely used in the medical physics community. For a filtered backprojection (FBP) reconstruction-based linear or quasilinear imaging system, the use of this methodology is well justified. Many key image quality metrics acquired with phantom studies can be directly applied to in vivo human subject studies. Recently, a variety of image quality metrics have been investigated for model-based iterative image reconstruction (MBIR) methods and several novel characteristics have been discovered in phantom studies. However, the following question remains unanswered: can certain results obtained from phantom studies be generalized to in vivo animal studies and human subject studies? The purpose of this paper is to address this question. One of the most striking results obtained from phantom studies is a novel power-law relationship between noise variance of MBIR (σ(2)) and tube current-rotation time product (mAs): σ(2) ∝ (mAs)(-0.4) [K. Li et al., "Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance," Med. Phys. 41, 041906 (15pp.) (2014)]. To examine whether the same power-law works for in vivo cases, experimental data from two types of in vivo studies were analyzed in this paper. All scans were performed with a 64-slice diagnostic CT scanner (Discovery CT750 HD, GE Healthcare) and reconstructed with both FBP and a MBIR method (Veo, GE Healthcare). An Institutional Animal Care and Use Committee-approved in vivo animal study was performed with an adult swine at six mAs levels (10-290). Additionally, human subject data (a total of 110 subjects) acquired from an IRB-approved clinical trial were analyzed. In this clinical trial, a reduced-mAs scan was performed immediately following the standard mAs scan; the specific mAs used for the two scans varied across human subjects and were determined based on patient size and clinical indications. The

  14. A computational model unifies apparently contradictory findings concerning phantom pain

    Science.gov (United States)

    Boström, Kim J.; de Lussanet, Marc H. E.; Weiss, Thomas; Puta, Christian; Wagner, Heiko

    2014-06-01

    Amputation often leads to painful phantom sensations, whose pathogenesis is still unclear. Supported by experimental findings, an explanatory model has been proposed that identifies maladaptive reorganization of the primary somatosensory cortex (S1) as a cause of phantom pain. However, it was recently found that BOLD activity during voluntary movements of the phantom positively correlates with phantom pain rating, giving rise to a model of persistent representation. In the present study, we develop a physiologically realistic, computational model to resolve the conflicting findings. Simulations yielded that both the amount of reorganization and the level of cortical activity during phantom movements were enhanced in a scenario with strong phantom pain as compared to a scenario with weak phantom pain. These results suggest that phantom pain, maladaptive reorganization, and persistent representation may all be caused by the same underlying mechanism, which is driven by an abnormally enhanced spontaneous activity of deafferented nociceptive channels.

  15. Application of Voxel Phantoms to Study the Influence of Heterogeneous Distribution of Actinides in Lungs on In Vivo Counting Calibration Factors Using Animal Experimentations

    Energy Technology Data Exchange (ETDEWEB)

    Lamart, S.; Pierrat, N.; De Carlan, L.; Franck, D. [IRSN/DRPH/SDI/LEDI, BP 17, F-92 262 Fontenay-aux-Roses (France); Dudoignon, N. [IRSN/DRPH/SRBE/LRPAT, BP 17, F-92 262 Fontenay-aux-Roses (France); Rateau, S.; Van der Meeren, A.; Rouit, E. [CEA/DSV/DRR/SRCA/LRT BP no 12, F-91680 Bruyeres-le-Chatel (France); Bottlaender, M. [CEA/SHFJ, 4, place du General Leclerc F-91400 Orsay (France)

    2006-07-01

    Calibration of lung counting system dedicated to retention assessment of actinides in the lungs remains critical due to large uncertainties in calibration factors. Among them, the detector positioning, the chest wall thickness and composition (muscle/fat) assessment, and the distribution of the contamination are the main parameters influencing the detector response. In order to reduce these uncertainties, a numerical approach based on the application of voxel phantoms (numerical phantoms based on tomographic images, CT or MRI) associated to a Monte-Carlo code (namely M.C.N.P.) was developed. It led to the development of a dedicated tool, called O.E.D.I.P.E., that allows to easily handle realistic voxel phantoms for the simulation of in vivo measurement (or dose calculation, application that will not be presented in this paper). The goal of this paper is to present our study of the influence of the lung distribution on calibration factors using both animal experimentations and our numerical method. Indeed, physical anthropomorphic phantoms used for calibration always consider a uniform distribution of the source in the lungs, which is not true in many contamination conditions. The purpose of the study is to compare the response of the measurement detectors using a real distribution of actinide particles in the lungs, obtained from animal experimentations, with the homogeneous one considered as the reference. This comparison was performed using O.E.D.I.P.E. that can almost simulate any source distribution. A non human primate was contaminated heterogeneously by intra-tracheal administration of actinide oxide. After euthanasia, gamma spectrometry measurements were performed on the pulmonary lobes to obtain the distribution of the contamination in the lungs. This realistic distribution was used to simulate an heterogeneous contamination in the numerical phantom of the non human primate, which was compared with a simulation of an homogeneous contamination presenting the

  16. In vitro biological effectiveness of JRR-4 epithermal neutron beam. Experiment under free air beam and in water phantom. Cooperative research

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tetsuya; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Tsukuba, Ibaraki (Japan); Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Hori, Naohiko; Torii, Yoshiya; Horiguchi, Yoji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-05-01

    The surviving curve and the biological effectiveness factor of dose components generated in boron neutron capture therapy (BNCT) were separately determined in neutron beams at Japan Research Reactor No.4. Surviving fraction of V79 Chinese hamster cell with or without {sup 10}B was obtained using an epithermal neutron beam (ENB), a mixed thermal-epithermal neutron beam (TNB-1), and a thermal neutron beam (TNB-2), which were used or planned to use for BNCT clinical trial. The cell killing effect of these neutron beams with or without the presence of {sup 10}B depended highly on the neutron beam used, according to the epithermal and fast neutron content in the beam. The biological effectiveness factor values of the boron capture reaction for ENB, TNB-1 and TNB-2 were 3.99{+-}0.24, 3.04{+-}0.19 and 1.43{+-}0.08, respectively. The biological effectiveness factor values of the high-LET dose components based on the hydrogen recoils and the nitrogen capture reaction were 2.50{+-}0.32, 2.34{+-}0.30 and 2.17{+-}0.28 for ENB, TNB-1 and TNB-2, respectively. The biological effectiveness factor values of the neutron and photon components were 1.22{+-}0.16, 1.23{+-}0.16 and 1.21{+-}0.16, respectively. The depth function of biological effectiveness factor in water phantom and the difference in biological effectiveness factor among boron compounds were also determined. The experimental determination of biological effectiveness factor outlined in this paper is applicable to the dose calculation for each dose component of the neutron beams and contribute to an accurate biological effectiveness factor as comparison with a neutron beam at a different facility employed in ongoing and planned BNCT clinical trials. (author)

  17. A phantom study for the comparison of different brands of computed tomography scanners and software packages for endovascular aneurysm repair sizing and planning.

    Science.gov (United States)

    Velu, Juliëtte F; Groot Jebbink, Erik; de Vries, Jean-Paul Pm; van der Palen, Job Am; Slump, Cornelis H; Geelkerken, Robert H

    2017-01-01

    Objectives Correct sizing of endoprostheses used for the treatment of abdominal aortic aneurysms is important to prevent endoleaks and migration. Sizing requires several steps and each step introduces a possible sizing error. The goal of this study was to investigate the magnitude of these errors compared to the golden standard: a vessel phantom. This study focuses on the errors in sizing with three different brands of computed tomography angiography scanners in combination with three reconstruction software packages. Methods Three phantoms with a different diameter, altitude and azimuth were scanned with three computed tomography scanners: Toshiba Aquilion 64-slice, Philips Brilliance iCT 256-slice and Siemens Somatom Sensation 64-slice. The phantom diameters were determined in the stretched view after central lumen line reconstruction by three observers using Simbionix PROcedure Rehearsal Studio, 3mensio and TeraRecon planning software. The observers, all novices in sizing endoprostheses using planning software, measured 108 slices each. Two senior vascular surgeons set the tolerated error margin of sizing on ±1.0 mm. Results In total, 11.3% of the measurements (73/648) were outside the set margins of ±1.0 mm from the phantom diameter, with significant differences between the scanner types (14.8%, 12.1%, 6.9% for the Siemens scanner, Philips scanner and Toshiba scanner, respectively, p-value = 0.032), but not between the software packages (8.3%, 11.1%, 14.4%, p-value = 0.141) or the observers (10.6%, 9.7%, 13.4%, p-value = 0.448). Conclusions It can be concluded that the errors in sizing were independent of the used software packages, but the phantoms scanned with Siemens scanner were significantly more measured incorrectly than the phantoms scanned with the Toshiba scanner. Consequently, awareness on the type of computed tomography scanner and computed tomography scanner setting is necessary, especially in complex abdominal aortic aneurysms

  18. SU-D-BRA-07: A Phantom Study to Assess the Variability in Radiomics Features Extracted From Cone-Beam CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Fave, X; Fried, D [UT MD Anderson Cancer Center, Houston, TX (United States); UT Health Science Center Graduate School of Biomedical Sciences, Houston, TX (United States); Zhang, L; Yang, J; Balter, P; Followill, D; Gomez, D; Jones, A; Stingo, F; Court, L [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: Several studies have demonstrated the prognostic potential for texture features extracted from CT images of non-small cell lung cancer (NSCLC) patients. The purpose of this study was to determine if these features could be extracted with high reproducibility from cone-beam CT (CBCT) images in order for features to be easily tracked throughout a patient’s treatment. Methods: Two materials in a radiomics phantom, designed to approximate NSCLC tumor texture, were used to assess the reproducibility of 26 features. This phantom was imaged on 9 CBCT scanners, including Elekta and Varian machines. Thoracic and head imaging protocols were acquired on each machine. CBCT images from 27 NSCLC patients imaged using the thoracic protocol on Varian machines were obtained for comparison. The variance for each texture measured from these patients was compared to the variance in phantom values for different manufacturer/protocol subsets. Levene’s test was used to identify features which had a significantly smaller variance in the phantom scans versus the patient data. Results: Approximately half of the features (13/26 for material1 and 15/26 for material2) had a significantly smaller variance (p<0.05) between Varian thoracic scans of the phantom compared to patient scans. Many of these same features remained significant for the head scans on Varian (12/26 and 8/26). However, when thoracic scans from Elekta and Varian were combined, only a few features were still significant (4/26 and 5/26). Three features (skewness, coarsely filtered mean and standard deviation) were significant in almost all manufacturer/protocol subsets. Conclusion: Texture features extracted from CBCT images of a radiomics phantom are reproducible and show significantly less variation than the same features measured from patient images when images from the same manufacturer or with similar parameters are used. Reproducibility between CBCT scanners may be high enough to allow the extraction of

  19. Optimization of in vitro and ex vitro regeneration and micromorphological studies in Basella alba L.

    Science.gov (United States)

    Shekhawat, Mahipal S; Manokari, M

    2016-10-01

    The optimum concentrations of the plant hormones for in vitro regeneration and subsequent effect of auxins on rooting (in vitro and ex vitro) of shoots of Basella alba L. have been investigated in present study. Nodal shoot segments were used as explants to initiate the cultures. The bud breaking from explants was observed within 1 week of incubation on agar gelled Murashige and Skoog's (MS) medium. Multiple axillary shoots (7.30 ± 0.56 shoots per explant) were induced on MS medium supplemented with 2.0 mg/L 6-benzylaminopurine (BAP). The shoots were multiplied (maximum 17.10 ± 0.44 shoots per explant) on the same medium fortified with 0.5 mg/L each of BAP and Kin (Kinetin) +0.1 mg/L IAA. These shoots were excised and rooted in vitro (10.73 ± 0.92 roots per shoot) on half-strength MS medium augmented with 2.0 mg/L indole-3 butyric acid (IBA). Hundred percentage success rates have been achieved by ex vitro rooting of the in vitro regenerated shoots with IBA at 300 mg/L. The in vitro and ex vitro rooted shoots were acclimatized in greenhouse and subsequently transferred to the natural field conditions where 100 % survival rate was reported. The ex vitro rooting method was found more advantageous than in vitro rooting in terms of time, energy and survival percentage of B. alba. A comparative foliar micromorphological study of B. alba was conducted to understand the micromorphological changes in plants while shifting from in vitro to the in vivo conditions in terms of variations in stomatal index, venation pattern and vein density, and the arrangement of crystals. The study could help in understanding the response of in vitro raised plants towards in vivo environment.

  20. Research article – Optimisation of paediatrics computed radiographyfor full spine curvature measurements using a phantom: a pilot study

    NARCIS (Netherlands)

    Daniel de Linde; Loris Franco; Catarina Serrenho; Peter Hogg; Ifrah Akhtar; José Antonio Garcia; Seraphine de Haan; Martine Thorskog; Cláudia Reis; Junior Ndlovu

    2015-01-01

    Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters:

  1. The impact of audio-visual biofeedback on 4D PET images: Results of a phantom study

    OpenAIRE

    Yang, Jaewon; Yamamoto, Tokihiro; Cho, Byungchul; Seo, Youngho; Keall, Paul J.

    2012-01-01

    Purpose: Irregular breathing causes motion blurring artifacts in 4D PET images. Audiovisual (AV) biofeedback has been demonstrated to improve breathing regularity. To investigate the hypothesis that, compared with free breathing, motion blurring artifacts are reduced with AV biofeedback, the authors performed the first experimental phantom-based quantification of the impact of AV biofeedback on 4D PET image quality.

  2. Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Boris [Goethe University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt (Germany); Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Eichler, Katrin; Siebenhandl, Petra; Gruber-Rouh, Tatjana; Vogl, Thomas Josef; Zangos, Stephan [Goethe University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt (Germany); Czerny, Christoph [Goethe University Hospital, Department of Trauma Surgery, Frankfurt (Germany)

    2013-01-15

    To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle guidance software. A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluoroscopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (n = 20 each). Target distance, needle deviation and time for the procedures were analysed. All phantom interventions (n = 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min). When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories. (orig.)

  3. Conversion of ICRP male reference phantom to polygon-surface phantom.

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-07

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom for highly penetrating radiations such as

  4. Conversion of ICRP male reference phantom to polygon-surface phantom

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom

  5. Revealing the invisible: the paradox of picturing a phantom limb.

    Science.gov (United States)

    Schott, G D

    2014-03-01

    Illustrations of phantom limbs are intriguing as they depict an invisible perception. But such illustrations are also important: they provide a form of objectivity to phenomena, which particularly in the past, have often stretched credulity. Acknowledging the paradox of using images to reveal an absent though sensate body part, depictions of phantom limbs are discussed from the neurological perspective, starting with medieval pictures that showed the miraculous restoration of limbs, and which possibly represented pictorial metaphors for a phantom limb. Centuries later, phantom limbs-whether resulting from amputation or deafferentation-became illustrated, and some reasons for their illustration are considered. Although often depicted by others, the most precise and perhaps revealing illustrations of these phantoms have been those made when patients guide the artist, or draw the phantom themselves. In the case of phantom pains, the painful component too is sometimes illustrated, again, as with the miraculous, in metaphorical terms. More recently, depictions of phantoms have also been revealing in studies of some underlying mechanisms of phantom phenomena, notably in demonstrating novel patterns of referred sensations after amputation and attributable to cortical plasticity. Mention is made of photographs of phantom hands visualized using a mirror box, such visualization recalling full circle the miraculous restoration of limbs pictured in the past. The nature of the outline of the phantom is included in a discussion of demarcation of an invisible body part, before concluding that images of phantom limbs provide an invaluable background to understanding and studying these remarkable sensory phenomena.

  6. SU-F-J-159: Influence of the Elevated Posterior Position by Using the Customized Vacuum-Bag On the Abdominal MR Image Quality: A Quantitative Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Wong, O; Yuan, J; Law, M; Ding, A; Yu, S; Cheung, K [Hong Kong Sanatorium & Hospital, Hong Kong, N/A (Hong Kong)

    2016-06-15

    Purpose: Signal-to-noise ratio(SNR) of MR abdominal imaging in diagnostic radiology is maximized by minimizing the coil-to-patient distance. However, for radiotherapy applications, customized vacuum-bag is needed for abdominal immobilization at the cost of the increasing distance to the posterior spine coil. This sub-optimized coil setting for RT applications may compromise image quality, such as SNR and homogeneity, thus potentially affect tissue delineation. In this study, we quantitatively evaluate the effect of the vertical position change on SNR and image quality change using an ACR MR phantom. Methods: An ACR MR phantom was placed on the flat couch top. Images were acquired using an 18-channel body array coil and spine coil on a dedicated 1.5T MR-simulator. The scan was repeated three times with the ACR phantom elevated up to 7.5cm from the couch top, with a step size of 2.5cm. All images were acquired using standard ACR test sequence protocol of 2D spin-echo T1-weighted(TR/TE=500/200ms) and T2-weighted(TR/TE1/TE2=2000/20/80) sequences. For all scans, pre-scan normalization was turned on, and the distance between the phantom and the anterior 18-channel body array coil was kept constant. SNR was calculated using the slice with a large water-only region of the phantom. Percent intensity uniformity(PIU) and low contrast object detectability(LCD) were assessed by following ACR test guidelines. Results: The decrease in image SNR(from 335.8 to 169.3) and LCD(T1: from 31 to 19 spokes, T2: 26 to 16 spokes) were observed with increasing vertical distance. After elevating the phantom by 2.5cm(approximately the thickness of standard vacuum-bag), SNR change(from 335.8 to 275.5) and LCD(T1: 31 to 26 spokes, T2: 26 to 21 spokes) change were noted. However, similar PIU was obtained for all choices of vertical distance (T1: 94.5%–95.0%, T2: 94.4%–96.8%). Conclusion: After elevating the scan object, reduction in SNR level and contrast detectability but no change in image

  7. Clinical performance diagnosing alleged exposure to falanga--a phantom study

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Matteoli, Sara; Wilhjelm, Jens E

    2009-01-01

    in approximately two thirds of the cases. The skin-to-bone distance affected the accuracy. CONCLUSION: The use of clinical examination in documenting alleged exposure to torture warrants a high diagnostic accuracy of the applied tests. The study implies that palpatory testing of the human heel pad may not meet...... this demand. It is therefore recommended that a device able to perform an accurate measurement of the viscous-elastic properties of the heel pad be developed....

  8. Proposal for study on IR light and glucose phantom interaction for human glucose quantification applications

    Science.gov (United States)

    Romo-Cárdenas, Gerardo S.; Sanchez-Lopez, Juan D.; Nieto-Hipolito, Juan I.; Cosio-León, María.; Luque-Morales, Priscy; Vazquez-Briseno, Mabel

    2016-09-01

    It has been established the importance of a constant glucose monitoring in order to keep a regular control for diabetes patients. Several medical studies accept the necessity of exploring alternatives for the traditional digital glucometer, given the pain and discomfort related to this technique, which can lead to a compromised control of the disease. Several efforts based on the application of IR spectroscopy had been done with favorable, yet not conclusive results. Therefore it's necessary to apply a comprehensive and interdisciplinary study based on the biochemical and optical properties of the glucose in the human body, in order to understand the interaction between this substance, its surroundings and IR light. These study propose a comprehensive approach of the glucose and IR light interaction, considering and combining important biochemical, physiological and optical properties, as well as some machine learning techniques for the data analysis. The results of this work would help to define the right parameters aiming to obtain an optical glucose quantification system and protocol.

  9. Detection of urinary stones at reduced radiation exposure: a phantom study comparing computed radiography and a low-dose digital radiography linear slit scanning system

    Science.gov (United States)

    Szucs-Farkas, Zsolt; Chakraborty, D. P.; Thoeny, Harriet C.; Loupatatzis, Christos; Vock, Peter; Harald, Bonel

    2010-01-01

    Objective In this experimental study we assessed the diagnostic performance of linear slit scanning radiography (LSSR) compared to conventional computed radiography (CR) in the detection of urinary calculi in an anthropomorphic phantom imitating patients weighing approximately 58 to 88 kg. Conclusion Compared to computed radiography, LSSR is superior in the detection of urinary stones and may be used for pretreatment localization and follow-up at a lower patient exposure. PMID:19457787

  10. Accuracy of iodine removal using dual-energy CT with or without a tin filter - An experimental phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Tatsuya; Takeuchi, Mitsuru; Hara, Masaki; Shibamoto, Yuta [Dept. of Radiology, Nagoya City Univ. Graduate School of Medical Sciences, Nagoya (Japan)], e-mail: tatsuyakawai@gmail.com; Ohashi, Kazuya [Div. of Central Radiology, Nagoya City Univ. Hospital, Nagoya (Japan); Suzuki, Hirochika; Yamada, Kiyotaka; Sugimura, Yuya [Div. of Radiology, Tsushima City Hospital, Tsushima City (Japan)

    2013-10-15

    Background: The effects of a tin filter on virtual non-enhanced (VNE) images created by dual-energy CT have not been well evaluated. Purpose: To compare the accuracy of VNE images between those with and without a tin filter. Material and Methods: Two different types of columnar phantoms made of agarose gel were evaluated. Phantom A contained various concentrations of iodine (4.5 - 1590 HU at 120 kVp). Phantom B consisted of a central component (0, 10, 25, and 40 mgI/cm{sup 3}) and a surrounding component (0, 50, 100, and 200 mgI/cm{sup 3}) with variable iodine concentration. They were scanned by dual-source CT in conventional single-energy mode and dual-energy mode with and without a tin filter. CT values on each gel at the corresponding points were measured and the accuracy of iodine removal was evaluated. Results: On VNE images, the CT number of the gel of Phantom A fell within the range between - 15 and +15 HU under 626 and 881 HU at single-energy 120 kVp with and without a tin filter, respectively. With attenuation over these thresholds, iodine concentration of gels was underestimated with the tin filter but overestimated without it. For Phantom B, the mean CT numbers on VNE images in the central gel component surrounded by the gel with iodine concentrations of 0, 50, 100, and 200 mgI/cm{sup 3} were in the range of -19 - +6 HU and 21 - 100 HU with and without the tin filter, respectively. Conclusion: Both with and without a tin filter, iodine removal was accurate under a threshold of iodine concentration. Although a surrounding structure with higher attenuation decreased the accuracy, a tin filter improved the margin of error.

  11. Proton radiography and fluoroscopy of lung tumors: A Monte Carlo study using patient-specific 4DCT phantoms

    Science.gov (United States)

    Han, Bin; Xu, X. George; Chen, George T. Y.

    2011-01-01

    Purpose: Monte Carlo methods are used to simulate and optimize a time-resolved proton range telescope (TRRT) in localization of intrafractional and interfractional motions of lung tumor and in quantification of proton range variations. Methods: The Monte Carlo N-Particle eXtended (MCNPX) code with a particle tracking feature was employed to evaluate the TRRT performance, especially in visualizing and quantifying proton range variations during respiration. Protons of 230 MeV were tracked one by one as they pass through position detectors, patient 4DCT phantom, and finally scintillator detectors that measured residual ranges. The energy response of the scintillator telescope was investigated. Mass density and elemental composition of tissues were defined for 4DCT data. Results: Proton water equivalent length (WEL) was deduced by a reconstruction algorithm that incorporates linear proton track and lateral spatial discrimination to improve the image quality. 4DCT data for three patients were used to visualize and measure tumor motion and WEL variations. The tumor trajectories extracted from the WEL map were found to be within ∼1 mm agreement with direct 4DCT measurement. Quantitative WEL variation studies showed that the proton radiograph is a good representation of WEL changes from entrance to distal of the target. Conclusions:MCNPX simulation results showed that TRRT can accurately track the motion of the tumor and detect the WEL variations. Image quality was optimized by choosing proton energy, testing parameters of image reconstruction algorithm, and comparing to ground truth 4DCT. The future study will demonstrate the feasibility of using the time resolved proton radiography as an imaging tool for proton treatments of lung tumors. PMID:21626923

  12. Study of Relative Quantitation of Tc-99m Annexin Localization in Pulmonary Nodules Using an Anthropomorphic Phantom

    Science.gov (United States)

    King, M.; Boening, Guido; Baker, S.; Steinmetz, N.

    2004-10-01

    In current clinical oncology practice, it often takes weeks or months of cancer therapy until a response to treatment can be identified by evaluation of tumor size in images. It is hypothesized that changes in relative localization of the apoptosis imaging agent Tc-99m Annexin before and after the administration of chemotherapy may be useful as an early indicator of the success of therapy. The objective of this study was to determine the minimum relative change in tumor localization that could be confidently determined as an increased localization. A modified version of the Data Spectrum Anthropomorphic Torso phantom, in which four spheres could be positioned in the lung region, was filled with organ concentrations of Tc-99m representative of those observed in clinical imaging of Tc-99m Annexin. Five acquisitions of an initial sphere to lung concentration, and at concentrations of 1.1, 1.2, 1.3, and 1.4 times the initial concentration, were acquired at clinically realistic count levels. The acquisitions were reconstructed by filtered backprojection, ordered subset expectation maximization (OSEM) without attenuation compensation (AC), and OSEM with AC. Permutation methodology was used to create multiple region-of-interest count ratios from the five noise realizations at each concentration and between the elevated and initial concentrations. The resulting distributions were approximated by Gaussians, which were then used to estimate the likelihood of Type 1 and Type 2 Errors. It was determined that for the cases investigated, greater than a 20% to 30% or more increase was needed to confidently determine that an increase in localization had occurred depending on sphere size and reconstruction strategy.

  13. Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels

    Science.gov (United States)

    Olsson, M-L; Siemund, R; Stålhammar, F; Björkman-Burtscher, I M; Söderberg, M

    2013-01-01

    Objective: To evaluate the image quality produced by six different iterative reconstruction (IR) algorithms in four CT systems in the setting of brain CT, using different radiation dose levels and iterative image optimisation levels. Methods: An image quality phantom, supplied with a bone mimicking annulus, was examined using four CT systems from different vendors and four radiation dose levels. Acquisitions were reconstructed using conventional filtered back-projection (FBP), three levels of statistical IR and, when available, a model-based IR algorithm. The evaluated image quality parameters were CT numbers, uniformity, noise, noise-power spectra, low-contrast resolution and spatial resolution. Results: Compared with FBP, noise reduction was achieved by all six IR algorithms at all radiation dose levels, with further improvement seen at higher IR levels. Noise-power spectra revealed changes in noise distribution relative to the FBP for most statistical IR algorithms, especially the two model-based IR algorithms. Compared with FBP, variable degrees of improvements were seen in both objective and subjective low-contrast resolutions for all IR algorithms. Spatial resolution was improved with both model-based IR algorithms and one of the statistical IR algorithms. Conclusion: The four statistical IR algorithms evaluated in the study all improved the general image quality compared with FBP, with improvement seen for most or all evaluated quality criteria. Further improvement was achieved with one of the model-based IR algorithms. Advances in knowledge: The six evaluated IR algorithms all improve the image quality in brain CT but show different strengths and weaknesses. PMID:24049128

  14. Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Hamersvelt, Robbert W. van; Willemink, Martin J.; Jong, Pim A. de; Schilham, Arnold M.R.; Leiner, Tim [University Medical Center Utrecht, Department of Radiology, P.O. Box 85500, Utrecht (Netherlands); Milles, Julien [CT Clinical Science, Philips HealthCare, Best (Netherlands); Vlassenbroek, Alain [CT Clinical Science, Philips HealthCare, Brussels (Belgium)

    2017-09-15

    The aim of this study was to evaluate the feasibility and accuracy of dual-layer spectral detector CT (SDCT) for the quantification of clinically encountered gadolinium concentrations. The cardiac chamber of an anthropomorphic thoracic phantom was equipped with 14 tubular inserts containing different gadolinium concentrations, ranging from 0 to 26.3 mg/mL (0.0, 0.1, 0.2, 0.4, 0.5, 1.0, 2.0, 3.0, 4.0, 5.1, 10.6, 15.7, 20.7 and 26.3 mg/mL). Images were acquired using a novel 64-detector row SDCT system at 120 and 140 kVp. Acquisitions were repeated five times to assess reproducibility. Regions of interest (ROIs) were drawn on three slices per insert. A spectral plot was extracted for every ROI and mean attenuation profiles were fitted to known attenuation profiles of water and pure gadolinium using in-house-developed software to calculate gadolinium concentrations. At both 120 and 140 kVp, excellent correlations between scan repetitions and true and measured gadolinium concentrations were found (R > 0.99, P < 0.001; ICCs > 0.99, CI 0.99-1.00). Relative mean measurement errors stayed below 10% down to 2.0 mg/mL true gadolinium concentration at 120 kVp and below 5% down to 1.0 mg/mL true gadolinium concentration at 140 kVp. SDCT allows for accurate quantification of gadolinium at both 120 and 140 kVp. Lowest measurement errors were found for 140 kVp acquisitions. (orig.)

  15. MO-FG-BRA-04: A Novel Time Weighted Density Correction for Stereotactic Lung Radiotherapy: A Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Mohatt, D; Malhotra, H [Roswell Park Cancer Institute, Buffalo, NY (United States)

    2016-06-15

    Purpose: Conventional treatment plans for lung radiotherapy are created using either the free breathing (FB) scheme which represents the tumor at an arbitrary breathing phase of the patient’s respiratory cycle, or the average computed tomography (ACT) intensity projection over 10-binned phases. Neither method is entirely accurate because of the absence of time dependence of tumor movement. In the present “Hybrid” method, the HU of tumor in 3D space is determined by relative weighting of the HU of the tumor and lung in proportion to the time they spend at that location during the entire breathing cycle. Methods: A Quasar respiratory motion phantom was employed to simulate lung tumor movement. Utilizing 4DCT image scans, volumetric modulated arc therapy (VMAT) plans were generated for three treatment planning scenarios which included conventional FB and ACT schemes, along with a third alternative Hybrid approach. Our internal target volume (ITV) hybrid structure was created using Boolean operation in Eclipse (ver. 11) treatment planning system, where independent sub-regions created by the gross tumor volume (GTV) overlap from the 10 motion phases were each assigned a time weighted CT value. The dose-volume-histograms (DVH) for each scheme were compared and analyzed. Results: Using our hybrid technique, we have demonstrated a reduction of 1.9% – 3.4% in total monitor units with respect to conventional treatment planning strategies, along with a 6 fold improvement in high dose spillage over the FB plan. The higher density ACT and Hybrid schemes also produced a slight enhancement in target conformity and reduction in low dose spillage. Conclusion: All treatment plans created in this study exceeded RTOG protocol criteria. Our results determine the free breathing approach yields an inaccurate account of the target treatment density. A significant decrease in unnecessary lung irradiation can be achieved by implementing Hybrid HU method with ACT method second best.

  16. 3D dosimetry estimation for selective internal radiation therapy (SIRT) using SPECT/CT images: a phantom study

    Science.gov (United States)

    Debebe, Senait A.; Franquiz, Juan; McGoron, Anthony J.

    2015-03-01

    Selective Internal Radiation Therapy (SIRT) is a common way to treat liver cancer that cannot be treated surgically. SIRT involves administration of Yttrium - 90 (90Y) microspheres via the hepatic artery after a diagnostic procedure using 99mTechnetium (Tc)-macroaggregated albumin (MAA) to detect extrahepatic shunting to the lung or the gastrointestinal tract. Accurate quantification of radionuclide administered to patients and radiation dose absorbed by different organs is of importance in SIRT. Accurate dosimetry for SIRT allows optimization of dose delivery to the target tumor and may allow for the ability to assess the efficacy of the treatment. In this study, we proposed a method that can efficiently estimate radiation absorbed dose from 90Y bremsstrahlung SPECT/CT images of liver and the surrounding organs. Bremsstrahlung radiation from 90Y was simulated using the Compton window of 99mTc (78keV at 57%). 99mTc images acquired at the photopeak energy window were used as a standard to examine the accuracy of dosimetry prediction by the simulated bremsstrahlung images. A Liqui-Phil abdominal phantom with liver, stomach and two tumor inserts was imaged using a Philips SPECT/CT scanner. The Dose Point Kernel convolution method was used to find the radiation absorbed dose at a voxel level for a three dimensional dose distribution. This method will allow for a complete estimate of the distribution of radiation absorbed dose by tumors, liver, stomach and other surrounding organs at the voxel level. The method provides a quantitative predictive method for SIRT treatment outcome and administered dose response for patients who undergo the treatment.

  17. Comparing the image quality of a mobile flat-panel computed tomography and a multidetector computed tomography: a phantom study.

    Science.gov (United States)

    Neubauer, Jakob; Voigt, Johannes M; Lang, Hannah; Scheuer, Carsten; Goerke, Sebastian M; Langer, Mathias; Fiebich, Martin; Kotter, Elmar

    2014-07-01

    The aim of this study was to compare the image quality of a compact mobile flat-panel computed tomography (FPCT) capable of extremity imaging and a multidetector computed tomography (MDCT) in examinations with the same radiation dose. Imaging with the FPCT was performed with default settings. Monte Carlo simulations were used to calculate equivalent dose settings for the 320-row MDCT. Simulations were based on and validated by dose measurements. Homogeneity, geometric distortion, artifacts, accuracy of Hounsfield values, contrast, and spatial resolution were evaluated in different imaging phantoms. Whitney-Mann U Test and Spearman ρ were used for statistical analysis. Homogeneity reached 2.5% for the FPCT and 0.5% for the MDCT. Hounsfield values were more accurate and contrast to noise ratios were higher for the MDCT than the FPCT (P ≤ 0.001). The MDCT depicted more rod inserts than the FPCT did. No significant geometric distortion was detected in either modality. The FPCT was more prone to artifacts around Krischner wires with a diameter of 2 mm (P = 0.05-0.001), whereas the MDCT showed a higher amount of artifacts around wires with a diameter of 0.8 mm (P ≤ 0.001). Spatial resolution was 1 lp/mm (xy), 1.7 lp/mm (z) for the FPCT and 1 lp/mm (xy), less than 1 lp/mm (z) for the MDCT. We compared a mobile FPCT and a 320-row MDCT by using the same radiation dose for scans. We found the spatial resolution to be higher in the FPCT. Hounsfield units were more accurate and homogeneity and contrast resolution were better in MDCT. The MDCT was also less prone to artifacts from thick Kirschner wires but showed comparably more artifacts around thin wires.

  18. Motor control over the phantom limb in above-elbow amputees and its relationship with phantom limb pain.

    Science.gov (United States)

    Gagné, M; Reilly, K T; Hétu, S; Mercier, C

    2009-08-04

    Recent evidence shows that the primary motor cortex continues to send motor commands when amputees execute phantom movements. These commands are retargeted toward the remaining stump muscles as a result of motor system reorganization. As amputation-induced reorganization in the primary motor cortex has been associated with phantom limb pain we hypothesized that the motor control of the phantom limb would differ between amputees with and without phantom limb pain. Eight above-elbow amputees with or without pain were included in the study. They were asked to produce cyclic movements with their phantom limb (hand, wrist, and elbow movements) while simultaneously reproducing the same movement with the intact limb. The time needed to complete a movement cycle and its amplitude were derived from the kinematics of the intact limb. Electromyographic (EMG) activity from different stump muscles and from the homologous muscles on the intact side was recorded. Different EMG patterns were recorded in the stump muscles depending on the movement produced, showing that different phantom movements are associated with distinct motor commands. Phantom limb pain was associated with some aspects of phantom limb motor control. The time needed to complete a full cycle of a phantom movement was systematically shorter in subjects without phantom limb pain. Also, the amount of EMG modulation recorded in a stump muscle during a phantom hand movement was positively correlated with the intensity of phantom limb pain. Since phantom hand movement-related EMG patterns in above-elbow stump muscles can be considered as a marker of motor system reorganization, this result indirectly supports the hypothesis that amputation-induced plasticity is associated with phantom limb pain severity. The discordance between the (amputated) hand motor command and the feedback from above-elbow muscles might partially explain why subjects exhibiting large EMG modulation during phantom hand movement have more phantom

  19. SU-F-T-114: A Novel Anatomically Predictive Extension Model of Computational Human Phantoms for Dose Reconstruction in Retrospective Epidemiological Studies of Second Cancer Risks in Radiotherapy Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kuzmin, G; Lee, C [National Cancer Institute, Rockville, MD (United States); Lee, C [University of Michigan, Ann Arbor, MI (United States); Pelletier, C; Jung, J [East Carolina University Greenville, NC (United States)

    2016-06-15

    Purpose: Recent advances in cancer treatments have greatly increased the likelihood of post-treatment patient survival. Secondary malignancies, however, have become a growing concern. Epidemiological studies determining secondary effects in radiotherapy patients require assessment of organ-specific dose both inside and outside the treatment field. An essential input for Monte Carlo modeling of particle transport is radiological images showing full patient anatomy. However, in retrospective studies it is typical to only have partial anatomy from CT scans used during treatment planning. In this study, we developed a multi-step method to extend such limited patient anatomy to full body anatomy for estimating dose to normal tissues located outside the CT scan coverage. Methods: The first step identified a phantom from a library of body size-dependent computational human phantoms by matching the height and weight of patients. Second, a Python algorithm matched the patient CT coverage location in relation to the whole body phantom. Third, an algorithm cut the whole body phantom and scaled them to match the size of the patient. Then, merged the two anatomies into one whole body. We entitled this new approach, Anatomically Predictive Extension (APE). Results: The APE method was examined by comparing the original chest-abdomen-pelvis CT images of the five patients with the APE phantoms developed from only the chest part of the CAP images and whole body phantoms. We achieved average percent differences of tissue volumes of 25.7%, 34.2%, 16.5%, 26.8%, and 31.6% with an average of 27% across all patients. Conclusion: Our APE method extends the limited CT patient anatomy to whole body anatomy by using image processing and computational human phantoms. Our ongoing work includes evaluating the accuracy of these APE phantoms by comparing normal tissue doses in the APE phantoms and doses calculated for the original full CAP images under generic radiotherapy simulations. This

  20. Effect of reconstruction methods and x-ray tube current–time product on nodule detection in an anthropomorphic thorax phantom: A crossed-modality JAFROC observer study

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, J. D., E-mail: j.d.thompson@salford.ac.uk [Directorate of Radiography, University of Salford, Frederick Road Campus, Salford, Greater Manchester M6 6PU, United Kingdom and Department of Radiology, Furness General Hospital, University Hospitals of Morecambe Bay NHS Foundation Trust, Dalton Lane, Barrow-in-Furness LA14 4LF (United Kingdom); Chakraborty, D. P. [Department of Radiology, University of Pittsburgh, FARP Building, Room 212, 3362 Fifth Avenue, Pittsburgh, Pennsylvania 15213 (United States); Szczepura, K.; Tootell, A. K. [Directorate of Radiography, University of Salford, Frederick Road Campus, Salford, Greater Manchester M6 6PU (United Kingdom); Vamvakas, I. [Department of Radiology, Christie Hospitals NHS Foundation Trust, 550 Wilmslow Road, Manchester M20 4BX (United Kingdom); Manning, D. J. [Faculty of Health and Medicine, Lancaster Medical School, Furness College, Lancaster University, Lancaster LA1 4YG (United Kingdom); Hogg, P. [Directorate of Radiography, University of Salford, Frederick Road Campus, Salford, Greater Manchester M6 6PU, United Kingdom and Department of Radiography, Karolinksa Institute, Solnavägen 1, Solna 171 77 (Sweden)

    2016-03-15

    Purpose: To evaluate nodule detection in an anthropomorphic chest phantom in computed tomography (CT) images reconstructed with adaptive iterative dose reduction 3D (AIDR{sup 3D}) and filtered back projection (FBP) over a range of tube current–time product (mAs). Methods: Two phantoms were used in this study: (i) an anthropomorphic chest phantom was loaded with spherical simulated nodules of 5, 8, 10, and 12 mm in diameter and +100, −630, and −800 Hounsfield units electron density; this would generate CT images for the observer study; (ii) a whole-body dosimetry verification phantom was used to ultimately estimate effective dose and risk according to the model of the BEIR VII committee. Both phantoms were scanned over a mAs range (10, 20, 30, and 40), while all other acquisition parameters remained constant. Images were reconstructed with both AIDR{sup 3D} and FBP. For the observer study, 34 normal cases (no nodules) and 34 abnormal cases (containing 1–3 nodules, mean 1.35 ± 0.54) were chosen. Eleven observers evaluated images from all mAs and reconstruction methods under the free-response paradigm. A crossed-modality jackknife alternative free-response operating characteristic (JAFROC) analysis method was developed for data analysis, averaging data over the two factors influencing nodule detection in this study: mAs and image reconstruction (AIDR{sup 3D} or FBP). A Bonferroni correction was applied and the threshold for declaring significance was set at 0.025 to maintain the overall probability of Type I error at α = 0.05. Contrast-to-noise (CNR) was also measured for all nodules and evaluated by a linear least squares analysis. Results: For random-reader fixed-case crossed-modality JAFROC analysis, there was no significant difference in nodule detection between AIDR{sup 3D} and FBP when data were averaged over mAs [F(1, 10) = 0.08, p = 0.789]. However, when data were averaged over reconstruction methods, a significant difference was seen between

  1. In vitro collagen fibril assembly: thermodynamic studies.

    Science.gov (United States)

    Na, G C; Phillips, L J; Freire, E I

    1989-09-05

    The in vitro fibril assembly of calf skin collagen was examined as a function of ionic strength and temperature. In a 0.03 M NaPi, pH 7.0, buffer, fibril assembly required a minimum critical concentration of collagen. At nearly physiological ionic strengths and temperatures, the critical concentration was less than 1 microgram/mL and required a very sensitive method for measurement. Raising the ionic strength of the buffer resulted first in higher and then lower critical concentrations. Raising the temperature led to lower critical concentrations. A van't Hoff plot of the fibril growth constant calculated from the critical concentration gave positive enthalpy changes and positive heat capacity changes which indicate that the fibril growth is driven by both hydrophobic and ionic inter-collagen interactions. Sedimentation equilibrium studies showed the collagen to be monomeric at subcritical concentrations. Differential scanning microcalorimetric studies showed only one very sharp heat absorption peak for the fibril assembly which coincided with the appearance of solution turbidity. Within experimental error, the enthalpy changes of the fibril assembly measured with the microcalorimeter were of the same magnitude as the van't Hoff enthalpy changes. These results are discussed in light of a cooperative nucleation-growth mechanism of collagen fibril assembly proposed earlier.

  2. Perceptions of phantom limb pain in lower limb amputees and its effect on quality of life: a qualitative study.

    Science.gov (United States)

    Trevelyan, Esmé G; Turner, Warren A; Robinson, Nicola

    2016-05-01

    Phantom limb pain (PLP) is a prevalent complication post-amputation. Currently, qualitative literature exploring the experience of PLP in amputees is sparse, and little is known about whether the educational needs of amputees are being met. To explore lower limb amputees' descriptive lived experiences of PLP, to understand how PLP affects quality of life and to determine whether amputees feel they are provided with adequate information about PLP. A qualitative descriptive approach, situated under the constructivist paradigm was taken, consisting of cross-sectional semi-structured interviews. A purposive sample of 15 lower limb amputees, 1-3 months post-surgery with past or current experience of PLP were interviewed once about their experience of PLP. Interviews were audio-recorded, transcribed verbatim and analysed using Framework Analysis. Interviews were conducted while participants were inpatients at an amputee rehabilitation unit in London. Six key themes were identified during analysis, of which three were related to PLP and are reported on in this article (real and physical phantoms, living with a phantom and being informed). PLP had numerous painful qualities. The phantom felt real, with kinetic and kinaesthetic properties. PLP had multiple meanings to amputees, was considered a reminder of circumstances and could affect quality of life. Information provided about PLP was inadequate. PLP can be a severe and annoying experience acting as a reminder of amputees' circumstances. Information provided about PLP is inadequate, with some amputees still perceiving PLP as mental and imaginary. Education about PLP and awareness and accessibility to non-pharmacological interventions needs to be improved.

  3. Study of effective atomic numbers and electron densities, kerma of alcohols, phantom and human organs, and tissues substitutes

    Directory of Open Access Journals (Sweden)

    Singh Vishwanath P.

    2013-01-01

    Full Text Available Effective atomic numbers (ZPIeff and electron densities of eighteen alcohols such as wood alcohol, CH3OH; grain alcohol, C2H5OH; rubbing alcohol, C3H7OH; butanol, C4H9OH; amyl alcohol, C5H11OH; cetyl alcohol, C16H33OH; ethylene glycol, C2H4(OH2; glycerin, C3H5(OH3; PVA, C2H4O; erythritol, C4H6(OH4; xylitol, C5H7(OH5; sorbitol, C6H8(OH6; volemitol, C7H9(OH7; allyl alcohol, C3H5OH; geraniol, C10H17OH; propargyl alcohol, C3H3OH; inositol, C6H6(OH6, and menthol, C10H19OH have been calculated in the photon energy region of 1 keV-100 GeV. The estimated values have been compared with experimental values wherever possible. The comparison of ZPIeff of the alcohols with water phantom and PMMA phantom indicate that the ethylene glycol, glycerin, and PVA are substitute for PMMA phantom and PVA is substitute of water phantom. ZPIeff of alcohols have also been compared with human organs and tissues. Ethylene glycol, glycerin and PVA, allyl alcohol, and wood alcohols are found tissue substitutes for most of human organs. Kerma which is the product of the energy fluence and mass energy-absorption coefficient, have been calculated in the energy region from 1 keV to 20 MeV for the alcohols. The results show the kerma is more or less independent of energy above 100 keV.

  4. Evaluation of six-point modified dixon and magnetic resonance spectroscopy for fat quantification: a fat-water-iron phantom study.

    Science.gov (United States)

    Fukuzawa, Kei; Hayashi, Tatsuya; Takahashi, Junji; Yoshihara, Chiharu; Tano, Masakatsu; Kotoku, Jun'ichi; Saitoh, Satoshi

    2017-09-01

    This study aimed to evaluate (1) the agreement between the true fat fraction (FF) and proton density FF (PDFF) measured using a six-echo modified Dixon (6mDixon) and magnetic resonance spectroscopy (MRS) and (2) the influence of fat on T2* values. The study was performed using phantoms of varying fat and iron content. Point-resolved spectroscopy (PRESS) and stimulated echo acquisition mode (STEAM) with single-echo (S) and multiecho (M) (PRESS-S, PRESS-M, STEAM-S, and STEAM-M) were used for MRS. In phantoms without iron, the agreement between the true FF and measured PDFF was tested using Bland-Altman analysis. The influence of iron on PDFF was evaluated in phantoms with iron. The relationship between the true FF and T2* value was assessed in phantoms without iron, wherein the mean differences (limits of agreement) for each method were as follows: 6mDixon 2.9% (-2.4 to 8.1%); STEAM-S 3.2% (-9.5 to 16.0%); STEAM-M -0.7% (-6.9 to 5.5%); PRESS-S 8.9% (-14.5 to 32.4%); and PRESS-M -5.8% (-18.3 to 6.7%). In the 20% fat phantoms with iron, as iron increased, PDFFs with STEAM-S, PRESS-S, and PRESS-M were considerably overestimated, while, PDFF with STEAM-M was stable at 0.04-0.2 mM iron concentrations (17.2 and 21.4%, respectively), and PDFF with 6mDixon was reliable at even 0.4 mM iron concentration (24.8%). The T2* value showed a negative correlation with the true FF (r = -0.942, P = 0.005). STEAM-M and 6mDixon were reliable methods of fat quantification in the absence of iron, and the T2* value was shortened by fat.

  5. Bonding brackets to porcelain: in vitro study

    Directory of Open Access Journals (Sweden)

    Sant'Anna Eduardo Franzotti

    2002-01-01

    Full Text Available The aim of this research was to verify, in vitro, the effect of various porcelain surface treatments on the shear strength of orthodontic brackets bonded to porcelain and the mode of fracture after debonding. Eighty-eight samples of metallic supported feldspathic porcelain were randomly divided into four groups according to their surface preparation as follows: the porcelain was maintained intact (GI, roughened with a diamond bur (GII, etched with 10% hydrofluoric acid (GIII, or sandblasted with aluminum oxide (GIV. The specimens were treated with silane (Scothprime and brackets were bonded with Concise. Each sample was subjected to a shear load at a crosshead speed of 1 mm/min and a recording was made at the point of failure. Bond strengths, adequate to withstand the application of orthodontic forces, were achieved in all groups. The Kruskal-Wallis statistical test showed no significant differences in bond strength between the groups (p>0.05. However, many more porcelain fractures occurred on deglazed porcelain. This study indicates that with the appropriate material selection, the silane/composite procedure alone may be adequate for bonding.

  6. Fabrication of Two Flow Phantoms for Doppler Ultrasound Imaging.

    Science.gov (United States)

    Zhou, Xiaowei; Kenwright, David A; Wang, Shiying; Hossack, John A; Hoskins, Peter R

    2017-01-01

    Flow phantoms are widely used in studies associated with Doppler ultrasound measurements, acting as an effective experimental validation system in cardiovascular-related research and in new algorithm/instrumentation development. The development of materials that match the acoustic and mechanical properties of the vascular system is of great interest while designing flow phantoms. Although recipes that meet the flow phantom standard defined by the International Electrotechnical Commission 61685 are already available in the literature, the standard procedure for material preparations and phantom fabrications has not been well established. In this paper, two types of flow phantoms, with and without blood vessel mimic, are described in detail in terms of the material preparation and phantom fabrication. The phantom materials chosen for the two phantoms are from published phantom studies, and their physical properties have been investigated previously. Both the flow phantoms have been scanned by ultrasound scanners and images from different modes are presented. These phantoms may be used in the validation and characterization of Doppler ultrasound measurements in blood vessels with a diameter above 1 mm.

  7. Toxicology Analysis of Tissue-Mimicking Phantom Made From Gelatin

    Science.gov (United States)

    Dolbashid, A. S.; Hamzah, N.; Zaman, W. S. W. K.; Mokhtar, M. S.

    2017-06-01

    Skin phantom mimics the biological skin tissues as it have the ability to respond to changes in its environment. The development of tissue-mimicking phantom could contributes towards the reduce usage of animal in cosmetics and pharmacokinetics. In this study, the skin phantoms made from gelatin were tested with four different commonly available cosmetic products to determine the toxicity of each substance. The four substances used were; mercury-based whitening face cream, carcinogenic liquid make-up foundation, paraben-based acne cleanser, and organic lip balm. Toxicity test were performed on all of the phantoms. For toxicity testing, topographical and electrophysiological changes of the phantoms were evaluated. The ability of each respective phantom to react with mild toxic substances and its electrical resistance were analysed in to determine the toxicity of all the phantom models. Four-electrode method along with custom made electrical impedance analyser was used to differentiate electrical resistance between intoxicated phantom and non-intoxicated phantom in this study. Electrical resistance values obtained from the phantom models were significantly higher than the control group. The result obtained suggests the phantom as a promising candidate to be used as alternative for toxicology testing in the future.

  8. Pipe Phantoms With Applications in Molecular Imaging and System Characterization.

    Science.gov (United States)

    Wang, Shiying; Herbst, Elizabeth B; Pye, Stephen D; Moran, Carmel M; Hossack, John A

    2017-01-01

    Pipe (vessel) phantoms mimicking human tissue and blood flow are widely used for cardiovascular related research in medical ultrasound. Pipe phantom studies require the development of materials and liquids that match the acoustic properties of soft tissue, blood vessel wall, and blood. Over recent years, pipe phantoms have been developed to mimic the molecular properties of the simulated blood vessels. In this paper, the design, construction, and functionalization of pipe phantoms are introduced and validated for applications in molecular imaging and ultrasound imaging system characterization. There are three major types of pipe phantoms introduced: 1) a gelatin-based pipe phantom; 2) a polydimethylsiloxane-based pipe phantom; and 3) the "Edinburgh pipe phantom." These phantoms may be used in the validation and assessment of the dynamics of microbubble-based contrast agents and, in the case of a small diameter tube phantom, for assessing imaging system spatial resolution/contrast performance. The materials and procedures required to address each of the phantoms are described.

  9. A new tool for touch-free patient registration for robot-assisted intracranial surgery: application accuracy from a phantom study and a retrospective surgical series.

    Science.gov (United States)

    Cardinale, Francesco; Rizzi, Michele; d'Orio, Piergiorgio; Casaceli, Giuseppe; Arnulfo, Gabriele; Narizzano, Massimo; Scorza, Davide; De Momi, Elena; Nichelatti, Michele; Redaelli, Daniela; Sberna, Maurizio; Moscato, Alessio; Castana, Laura

    2017-05-01

    OBJECTIVE The purpose of this study was to compare the accuracy of Neurolocate frameless registration system and frame-based registration for robotic stereoelectroencephalography (SEEG). METHODS The authors performed a 40-trajectory phantom laboratory study and a 127-trajectory retrospective analysis of a surgical series. The laboratory study was aimed at testing the noninferiority of the Neurolocate system. The analysis of the surgical series compared Neurolocate-based SEEG implantations with a frame-based historical control group. RESULTS The mean localization errors (LE) ± standard deviations (SD) for Neurolocate-based and frame-based trajectories were 0.67 ± 0.29 mm and 0.76 ± 0.34 mm, respectively, in the phantom study (p = 0.35). The median entry point LE was 0.59 mm (interquartile range [IQR] 0.25-0.88 mm) for Neurolocate-registration-based trajectories and 0.78 mm (IQR 0.49-1.08 mm) for frame-registration-based trajectories (p = 0.00002) in the clinical study. The median target point LE was 1.49 mm (IQR 1.06-2.4 mm) for Neurolocate-registration-based trajectories and 1.77 mm (IQR 1.25-2.5 mm) for frame-registration-based trajectories in the clinical study. All the surgical procedures were successful and uneventful. CONCLUSIONS The results of the phantom study demonstrate the noninferiority of Neurolocate frameless registration. The results of the retrospective surgical series analysis suggest that Neurolocate-based procedures can be more accurate than the frame-based ones. The safety profile of Neurolocate-based registration should be similar to that of frame-based registration. The Neurolocate system is comfortable, noninvasive, easy to use, and potentially faster than other registration devices.

  10. A novel breast software phantom for biomechanical modeling of elastography.

    Science.gov (United States)

    Bhatti, Syeda Naema; Sridhar-Keralapura, Mallika

    2012-04-01

    In developing breast imaging technologies, testing is done with phantoms. Physical phantoms are normally used but their size, shape, composition, and detail cannot be modified readily. These difficulties can be avoided by creating a software breast phantom. Researchers have created software breast phantoms using geometric and/or mathematical methods for applications like image fusion. The authors report a 3D software breast phantom that was built using a mechanical design tool, to investigate the biomechanics of elastography using finite element modeling (FEM). The authors propose this phantom as an intermediate assessment tool for elastography simulation; for use after testing with commonly used phantoms and before clinical testing. The authors design the phantom to be flexible in both, the breast geometry and biomechanical parameters, to make it a useful tool for elastography simulation. The authors develop the 3D software phantom using a mechanical design tool based on illustrations of normal breast anatomy. The software phantom does not use geometric primitives or imaging data. The authors discuss how to create this phantom and how to modify it. The authors demonstrate a typical elastography experiment of applying a static stress to the top surface of the breast just above a simulated tumor and calculate normal strains in 3D and in 2D with plane strain approximations with linear solvers. In particular, they investigate contrast transfer efficiency (CTE) by designing a parametric study based on location, shape, and stiffness of simulated tumors. The authors also compare their findings to a commonly used elastography phantom. The 3D breast software phantom is flexible in shape, size, and location of tumors, glandular to fatty content, and the ductal structure. Residual modulus, maps, and profiles, served as a guide to optimize meshing of this geometrically nonlinear phantom for biomechanical modeling of elastography. At best, low residues (around 1-5 KPa) were

  11. In-vitro Release Study of Carvedilol Phosphate Matrix Tablets ...

    African Journals Online (AJOL)

    The tablets were compressed using a compression force and compression time of 5 tons and 20 s, respectively. Prior to compression, the die and punch surfaces were sufficiently lubricated with magnesium stearate. In vitro release studies. In vitro drug release studies of the matrix tablets were carried out using a six-station.

  12. In vitro study of interaction between quinine and Garcinia kola

    African Journals Online (AJOL)

    Purpose: To investigate the interaction between quinine and Garcinia kola using an in vitro adsorption study. Methods: In vitro interaction between quinine and G. kola was conducted at 37 ± 0.1 °C. Adsorption of quinine (2.5 - 40 µg/ml) to 2.5 % w/v G. kola suspension was studied. Thereafter, quinine desorption process ...

  13. Can neural blocks prevent phantom limb pain?

    Science.gov (United States)

    Borghi, Battista; D'Addabbo, Marco; Borghi, Raffaele

    2014-07-01

    Phantom limb syndrome (PLS) is a syndrome including stump pain, phantom limb pain and not-painful phantom sensations, which involves a large part of amputee patients and often has devastating effects on their quality of life. The efficacy of standard therapies is very poor. Nerve blocks have been investigated for the treatment and prevention of PLS. Epidural and peripheral blocks limited to the first three postamputation days can only reduce acute pain but cannot prevent the later development of PLS. Recent studies have shown that ambulatory prolonged peripheral nerve block (up to 30 days postamputation) may represent a new possible option to treat phantom pain and prevent the development of PLS and chronic pain.

  14. Phantom perception: voluntary and involuntary nonretinal vision.

    Science.gov (United States)

    Pearson, Joel; Westbrook, Fred

    2015-05-01

    Hallucinations, mental imagery, synesthesia, perceptual filling-in, and many illusions are conscious visual experiences without a corresponding retinal stimulus: what we call 'phantom perception'. Such percepts show that our experience of the world is not solely determined by direct sensory input. Some phantom percepts are voluntary, whereas others are involuntarily, occurring automatically. Here, by way of review, we compare and contrast these two types of phantom perception and their neural representations. We propose a dichotomous framework for phantom vision, analogous to the subtypes of attention: endogenous and exogenous. This framework unifies findings from different fields and species, providing a guide to study the constructive nature of conscious sensory perception. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET-MR: Phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chuan; Brady, Thomas J.; El Fakhri, Georges; Ouyang, Jinsong, E-mail: ouyang.jinsong@mgh.harvard.edu [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Ackerman, Jerome L. [Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts 02129 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Petibon, Yoann [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States)

    2014-04-15

    Purpose: Artifacts caused by head motion present a major challenge in brain positron emission tomography (PET) imaging. The authors investigated the feasibility of using wired active MR microcoils to track head motion and incorporate the measured rigid motion fields into iterative PET reconstruction. Methods: Several wired active MR microcoils and a dedicated MR coil-tracking sequence were developed. The microcoils were attached to the outer surface of an anthropomorphic{sup 18}F-filled Hoffman phantom to mimic a brain PET scan. Complex rotation/translation motion of the phantom was induced by a balloon, which was connected to a ventilator. PET list-mode and MR tracking data were acquired simultaneously on a PET-MR scanner. The acquired dynamic PET data were reconstructed iteratively with and without motion correction. Additionally, static phantom data were acquired and used as the gold standard. Results: Motion artifacts in PET images were effectively removed by wired active MR microcoil based motion correction. Motion correction yielded an activity concentration bias ranging from −0.6% to 3.4% as compared to a bias ranging from −25.0% to 16.6% if no motion correction was applied. The contrast recovery values were improved by 37%–156% with motion correction as compared to no motion correction. The image correlation (mean ± standard deviation) between the motion corrected (uncorrected) images of 20 independent noise realizations and static reference was R{sup 2} = 0.978 ± 0.007 (0.588 ± 0.010, respectively). Conclusions: Wired active MR microcoil based motion correction significantly improves brain PET quantitative accuracy and image contrast.

  16. [Value of densitometry in the computer tomographic differentiation of paracranial space-occupying lesions. Experimental phantom studies and clinical evaluation].

    Science.gov (United States)

    Schmitt, W G; Voigt, K

    1983-03-01

    Hardening of the beam is a major disturbing effect in densitometry close to the calotte. This phenomenon is demonstrated in a phantom, and its theoretical base is discussed. If possible sources of error are considered and reduced by means of appropriate measuring conditions, measurement of density will furnish useful additional data in CT examination. The value of CT densitometry is demonstrated via follow-up observations; after an operation of a glioma of the optic nerve, a child developed hygromas complicated by superinfection which subsequently became horny or calcified.

  17. 3-D Imaging using Row–Column-Addressed 2-D Arrays with a Diverging Lens: Phantom Study

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Beers, Christopher

    2017-01-01

    A double-curved diverging lens over a flat row– column-addressed (RCA) 2-D array can extend its inherent rectilinear 3-D imaging field-of-view (FOV) to a curvilinear volume region, which is necessary for applications such as abdominal and cardiac imaging. A concave lens with radius of 12.7 mm...... was manufactured using RTV664 silicone. The diverging properties of the lens were evaluated based on measurements on several phantoms. The measured 6 dB FOV in contact with a material similar to human soft tissue was less than 15% different from the theoretical predictions, i.e., a curvilinear FOV of 32...

  18. MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lai, C; Zhong, Y; Wang, T; Shaw, C [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor.

  19. [X-ray bone densitometry. Study of in vitro and in vivo reproducibility].

    Science.gov (United States)

    Luisetto, G; Zangari, M; Ridolfi, P; Tizian, L; Ziliotto, D

    1991-01-01

    We studied the reproducibility in vitro and in vivo of a new bone densitometer (HOLOGIC QDR-1000, software version 4.03) which uses an x-ray source at two different levels of energy. Short and long term coefficient of variation (c.v.) in vitro is less than 0.5%. In vivo c.v. is less than 1% in normal body weight subjects and less than 3% in obese subjects. The ingestion of 500 mg of calcium element did not modify bone mineral density (BMD), while 1000 mg determined an increase of BMD equal to 2.6% and 1.5% in the two subjects examined. The increase of water thickness on a three femoral heads phantom caused a progressive reduction of bone mineral content (BMC) and BMD until 12.1% less than basal value and an increase of c.v. from 0.1% to 1%. The addition of oil to water at different percentages determined a slight increase of both BMC and BMD, till 3.5% with 66% of oil in water, if compared with the values obtained with water alone. The reduction of soft tissue around the bone determined a progressive decrease of BMD reaching 3.4% less than basal value when the reduction was 30%.

  20. The menacing phantom: what pulls the trigger?

    Science.gov (United States)

    Giummarra, Melita J; Georgiou-Karistianis, Nellie; Nicholls, Michael E R; Gibson, Stephen J; Chou, Michael; Bradshaw, John L

    2011-08-01

    Phantom phenomena are frequent following amputation, but how this often painful experience is modified or triggered by spontaneous events or sensations often puzzles amputees and clinicians alike. We explored triggers of phantom phenomena in a heterogeneous sample of 264 upper and lower limb adult amputees with phantom sensations. Participants completed a structured questionnaire to determine the prevalence and nature of the triggers of phantom phenomena. The four categories of triggers identified include: (a) a quarter of participants experiencing psychological, emotional or autonomic triggers; (b) half experiencing behavioral triggers, "forgetting" the limb's absence and attempting to use the phantom; (c) one-fifth experiencing weather-induced triggers; and (d) one-third experiencing sensations referred from parts of the body. Upper limb amputees; and were more likely to experience weather-induced phantom phenomena than lower limb amputees; and upper and lower limb amputees were equally likely to experience referred sensations from the genitals, contradicting the homuncular remapping hypothesis. Traumatic amputees were more likely to report emotional triggers. Further, while those with emotional triggers exhibited poorer acceptance of the limitations of amputation, they were more likely to employ adaptive coping mechanisms. Finally, habitual "forgetting" behaviors were most common soon after amputation, whereas other more adaptive schemata (e.g., self-defense) were equally likely to be performed at any time following amputation. Various likely inter-related mechanisms are discussed in relation to phantom triggers. Ultimately, optimizing stump and neuroma management, as well as restoring function of central networks for pain, limb movement, and amputation-related memories, should help manage spontaneously triggered phantom phenomena. Copyright © 2011 European Federation of International Association for the Study of Pain Chapters. All rights reserved.

  1. Percutaneous Image-Guided Cryoablation for the Treatment of Phantom Limb Pain in Amputees: A Pilot Study.

    Science.gov (United States)

    Prologo, J David; Gilliland, Charles A; Miller, Michael; Harkey, Paul; Knight, Jackie; Kies, Darren; Hawkins, C Matthew; Corn, David; Monson, David K; Edalat, Faramarz; Dariushnia, Sean; Brewster, Luke

    2017-01-01

    To prospectively evaluate percutaneous image-guided nerve cryoablation for treatment of refractory phantom limb pain (PLP) in a pilot cohort for purposes of deriving parameters to design a larger, randomized, parallel-armed, controlled trial. From January 2015 to January 2016, 21 patients with refractory PLP underwent image-guided percutaneous cryoneurolysis procedures. Visual analog scale scores were documented at baseline and 7, 45, and 180 days after the procedure. Responses to a modified Roland Morris Disability Questionnaire were documented at baseline and 7 and 45 days after the procedure. Technical success rate of the procedures was 100%. There were 6 (29%) minor procedure-related complications. Disability scores decreased from a baseline mean of 11.3 to 3.3 at 45-day follow-up (95% confidence interval 5.8, 10.3; P < .0001). Pain intensity scores decreased from a baseline mean of 6.2 to 2.0 at long-term follow-up (95% confidence interval 2.8, 5.6; P < .0001). Image-guided percutaneous nerve cryoablation is feasible and safe and may represent a new efficacious therapeutic option for patients with phantom pains related to limb loss. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  2. Highly accelerated acquisition and homogeneous image reconstruction with rotating RF coil array at 7T-A phantom based study.

    Science.gov (United States)

    Li, Mingyan; Zuo, Zhentao; Jin, Jin; Xue, Rong; Trakic, Adnan; Weber, Ewald; Liu, Feng; Crozier, Stuart

    2014-03-01

    Parallel imaging (PI) is widely used for imaging acceleration by means of coil spatial sensitivities associated with phased array coils (PACs). By employing a time-division multiplexing technique, a single-channel rotating radiofrequency coil (RRFC) provides an alternative method to reduce scan time. Strategically combining these two concepts could provide enhanced acceleration and efficiency. In this work, the imaging acceleration ability and homogeneous image reconstruction strategy of 4-element rotating radiofrequency coil array (RRFCA) was numerically investigated and experimental validated at 7T with a homogeneous phantom. Each coil of RRFCA was capable of acquiring a large number of sensitivity profiles, leading to a better acceleration performance illustrated by the improved geometry-maps that have lower maximum values and more uniform distributions compared to 4- and 8-element stationary arrays. A reconstruction algorithm, rotating SENSitivity Encoding (rotating SENSE), was proposed to provide image reconstruction. Additionally, by optimally choosing the angular sampling positions and transmit profiles under the rotating scheme, phantom images could be faithfully reconstructed. The results indicate that, the proposed technique is able to provide homogeneous reconstructions with overall higher and more uniform signal-to-noise ratio (SNR) distributions at high reduction factors. It is hoped that, by employing the high imaging acceleration and homogeneous imaging reconstruction ability of RRFCA, the proposed method will facilitate human imaging for ultra high field MRI. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. A nonlinear elasticity phantom containing spherical inclusions

    Science.gov (United States)

    Pavan, Theo Z.; Madsen, Ernest L.; Frank, Gary R.; Jiang, Jingfeng; Carneiro, Antonio A. O.; Hall, Timothy J.

    2012-08-01

    The strain image contrast of some in vivo breast lesions changes with increasing applied load. This change is attributed to differences in the nonlinear elastic properties of the constituent tissues suggesting some potential to help classify breast diseases by their nonlinear elastic properties. A phantom with inclusions and long-term stability is desired to serve as a test bed for nonlinear elasticity imaging method development, testing, etc. This study reports a phantom designed to investigate nonlinear elastic properties with ultrasound elastographic techniques. The phantom contains four spherical inclusions and was manufactured from a mixture of gelatin, agar and oil. The phantom background and each of the inclusions have distinct Young's modulus and nonlinear mechanical behavior. This phantom was subjected to large deformations (up to 20%) while scanning with ultrasound, and changes in strain image contrast and contrast-to-noise ratio between inclusion and background, as a function of applied deformation, were investigated. The changes in contrast over a large deformation range predicted by the finite element analysis (FEA) were consistent with those experimentally observed. Therefore, the paper reports a procedure for making phantoms with predictable nonlinear behavior, based on independent measurements of the constituent materials, and shows that the resulting strain images (e.g., strain contrast) agree with that predicted with nonlinear FEA.

  4. Appropriateness of internal digital phantoms for monitoring the stability of the UBIS 5000 quantitative ultrasound device in clinical trials.

    Science.gov (United States)

    Hans, D; Alekxandrova, I; Njeh, C; Le-Floch, C; Conicella, G; Laugier, P; Slosman, D O

    2005-04-01

    In bone status assessment, proper quality assurance/quality control is crucial since changes due to disease or therapeutic treatment are very small, in the order of 2-5%. Unlike for dual X-ray absorptiometry, quality control procedures have not been extensively developed and validated for quantitative ultrasound technology, limiting its use in longitudinal monitoring. While the challenge of developing an ideal anthropometric phantom is still open, some manufacturers use the concept of the internal digital phantom mimicking human characteristics to check the stability of their device. The objective of the study was to develop a sensitive model of quality control suitable for the correction of QUS patient data. In order to achieve this goal, we simulated a longitudinal device lifetime with both correct and malfunctioning behaviors. Then, we verified the efficiency of digital phantoms in detecting those changes and subsequently established the in vitro/in vivo relationship. This is the first time that an attempt to validate an internal digital phantom has made, and that this type of validation approach is used. The digital phantom (DP) was designed to mimic normal bone (BUAP2) and osteoporotic bone (BUAP1) properties. The DP was studied using the UBIS 5000 ultrasound device (DMS, France). Diverse malfunctions of the UBIS-5000 were simulated. Several series of measurements were performed on both BUAP1 and 2 and on 12 volunteers at each grade of malfunction. The effect of each simulated malfunction on in vivo and in vitro results was presented graphically by plotting the average BUA values against the percentage change from baseline. The change from baseline in BUA was modeled using linear regression, and the in vivo/in vitro ratio was obtained from the model. All experimentations influenced the measure of BUAP1 and 2 as well as the measure of our 12 volunteers. However, the degree of significance varied as a function of the severity of the malfunction, and the results

  5. Jamitons: Phantom Traffic Jams

    Science.gov (United States)

    Kowszun, Jorj

    2013-01-01

    Traffic on motorways can slow down for no apparent reason. Sudden changes in speed by one or two drivers can create a chain reaction that causes a traffic jam for the vehicles that are following. This kind of phantom traffic jam is called a "jamiton" and the article discusses some of the ways in which traffic engineers produce…

  6. The Phantom Menace

    DEFF Research Database (Denmark)

    Vium, Christian

    2013-01-01

    as a phantom menace, which asserts itself through a form of omnipresent fear, nurtured by an inherent opaqueness. As this fundamental fear progressively permeates the nomadic landscape, it engenders a recasting of mobile strategies among the nomadic pastoralist groups who inhabit the interstitial desert spaces....

  7. A computer simulated phantom study of tomotherapy dose optimization based on probability density functions (PDF) and potential errors caused by low reproducibility of PDF.

    Science.gov (United States)

    Sheng, Ke; Cai, Jing; Brookeman, James; Molloy, Janelle; Christopher, John; Read, Paul

    2006-09-01

    Lung tumor motion trajectories measured by four-dimensional CT or dynamic MRI can be converted to a probability density function (PDF), which describes the probability of the tumor at a certain position, for PDF based treatment planning. Using this method in simulated sequential tomotherapy, we study the dose reduction of normal tissues and more important, the effect of PDF reproducibility on the accuracy of dosimetry. For these purposes, realistic PDFs were obtained from two dynamic MRI scans of a healthy volunteer within a 2 week interval. The first PDF was accumulated from a 300 s scan and the second PDF was calculated from variable scan times from 5 s (one breathing cycle) to 300 s. Optimized beam fluences based on the second PDF were delivered to the hypothetical gross target volume (GTV) of a lung phantom that moved following the first PDF The reproducibility between two PDFs varied from low (78%) to high (94.8%) when the second scan time increased from 5 s to 300 s. When a highly reproducible PDF was used in optimization, the dose coverage of GTV was maintained; phantom lung receiving 10%-20% prescription dose was reduced by 40%-50% and the mean phantom lung dose was reduced by 9.6%. However, optimization based on PDF with low reproducibility resulted in a 50% underdosed GTV. The dosimetric error increased nearly exponentially as the PDF error increased. Therefore, although the dose of the tumor surrounding tissue can be theoretically reduced by PDF based treatment planning, the reliability and applicability of this method highly depend on if a reproducible PDF exists and is measurable. By correlating the dosimetric error and PDF error together, a useful guideline for PDF data acquisition and patient qualification for PDF based planning can be derived.

  8. Model based iterative reconstruction IMR gives possibility to evaluate thinner slice thicknesses than conventional iterative reconstruction iDose4: a phantom study

    Science.gov (United States)

    Aurumskjöld, Marie-Louise; Ydström, Kristina; Tingberg, Anders; Söderberg, Marcus

    2015-03-01

    Computed tomography (CT) is one of the most important modalities in a radiological department, which produces images with high diagnostic confidence, but in some cases contributes to a high radiation dose to the patient. The radiation dose can be reduced by the use of advanced image reconstruction algorithms. This study was done on a Philips Brilliance iCT with iterative reconstruction iDose4 and model-based iterative reconstruction IMR. The purpose was to investigate the effect on the image quality with thin slice images reconstructed with IMR, compared to standard slice thickness reconstructed with iDose4. Objective measurements of noise and contrast-to-noise ratio were performed using an image quality phantom, an anthropomorphic phantom and clinical cases. Subjective evaluations of low-contrast resolution were performed by observers using an image quality phantom. IMR gives strong noise reduction and enhanced low-contrast and thereby enable selection of thinner slice thickness. Objective evaluation of image noise shows that thin slices reconstructed with IMR provides lower noise than thicker slice images reconstructed with iDose4. With IMR the slice thickness is of less importance for the noise. With thinner slices the partial volume artefacts becomes less pronounced. In conclusion, we have shown that IMR enables reduction of the slice thickness and at the same time maintain or even reduce the noise level compared to iDose4 reconstruction with standard slice thickness. This will subsequently result in an improvement of image quality for images reconstructed with IMR.

  9. A realistic pelvic phantom for electrical impedance measurement.

    Science.gov (United States)

    Dunne, Eoghan; McGinley, Brian; O'Halloran, Martin; Porter, Emily

    2017-12-22

    To design and fabricate an anatomically and conductively accurate phantom for electrical impedance studies of non-invasive bladder volume monitoring. Approach: A modular pelvic phantom was designed and fabricated, consisting of a mechanically and conductively stable boundary wall, a background medium, and bladder phantoms. The wall and bladders are made of conductive polyurethane. The background material is an ultrasound gel-based mixture, with conductivity matched to a weighted average of the pelvic cavity organs, bone, muscle and fat. The phantom boundary is developed using a computer tomography model of a male human pelvis. The bladder phantoms were designed to correlate with human bladder dimensions. Electrical impedance measurements of the phantom were recorded, and images produced using six different bladder phantoms and a realistic finite element model. Main results: Five different bladder volumes were successfully imaged using an empty bladder as a reference. The average conductivity index from the reconstructed images showed a strong positive correlation with the bladder phantom volumes. Significance: A conductively and anatomically accurate pelvic phantom was developed for non-invasive bladder volume monitoring using electrical impedance measurements. Several bladders were designed to correlate with actual human bladder volumes, allowing for accurate volume estimation. The conductivity of the phantom is accurate over 50-250 kHz. This phantom can allow: changeable electrode location, contact and size; multi-layer electrodes configurations; increased complexity by addition of other organ or bone phantoms; and electrode movement and deformation. Overall, the pelvic phantom enables greater scope for experimentation and system refinement as a precursor to in-man clinical studies. © 2017 Institute of Physics and Engineering in Medicine.

  10. Development of an Arm Phantom for Testing Non-Invasive Blood Pressure Monitors

    Science.gov (United States)

    Anderson-Jackson, LaTecia D.

    Approximately one in every three adults age 20 older are diagnosed with high blood pressure or hypertension. It is estimated that hypertension affects 78 million people in the United States, is equally prevalent in both men and woman (Crabtree, Stuart-Shor, & McAllister, 2013). In the United States, around 78% of people suffering from hypertension are aware of their condition, with only 68% using hypertensive medications to control their blood pressure (Writing Group et al., 2010). Clinically, blood pressure measurements may lack accuracy, which can be attributed to various factors, including device limitations, cuff mis-sizing and misplacement, white-coat effect, masked hypertension, and lifestyle factors. The development of an arm phantom to simulate physiologic properties of a human arm and arterial BP waveforms may allow us to better assess the accuracy of non-invasive blood pressure (NIBP) monitors. The objective of this study are to: (1) Develop an arm phantom to replicate physiological properties of the human arm, and (2) Incorporate the arm phantom into a mock circulatory flow loop to simulate different physiological blood pressure readings on the bench. A tissue mimicking material, styrene-ethylene-butylene-styrene (SEBS), a co-block polymer was used to develop the arm phantom for in-vitro testing. To determine the optimal mechanical properties for the arm phantom, individual arm components were isolated and tested. A protocol was developed to evaluate various components for optimal arm phantom development. Mechanical testing was conducted on 10%, 15%, and 20% SEBS gel samples for modulus of elasticity measurements in order to simulate physiological properties of the human arm. As a result of the SEBS polymer being a new material for this application, this investigation will contribute to resolving the limitations that occurred during experimentation. In this study, we demonstrated that although SEBS polymer may be an ideal material to use for simulating

  11. Phantom pain after eye amputation

    DEFF Research Database (Denmark)

    Rasmussen, Marie L R; Prause, Jan U; Toft, Peter B

    2011-01-01

    Purpose: To characterize the quality of phantom pain, its intensity and frequency following eye amputation. Possible triggers and relievers of phantom pain are investigated. Methods: The hospital database was searched using surgery codes for patients who received ocular evisceration, enucleation,...... appears to be similar to the phantom pain suffered by limb amputees. Patients should be informed about this potential complication before surgery....

  12. Brachial plexus block in phantom limb pain: a case report.

    Science.gov (United States)

    Preissler, Sandra; Dietrich, Caroline; Meissner, Winfried; Huonker, Ralph; Hofmann, Gunther O; Miltner, Wolfgang H R; Weiss, Thomas

    2011-11-01

    The purpose of this case report is twofold: first, to present evidence of long-lasting relief in a patient suffering from phantom limb pain after pharmacologically blocking his plexus brachialis and, second, to replicate results from a previous study focusing on cortical reorganization and phantom limb pain. Before regional anesthesia, the patient suffered from a phantom hand that cramped and was immovable. We performed a diagnostic axillary blockade of the brachial plexus to differentiate peripheral from more central contributions to phantom limb pain. During blockade of the brachial plexus, the patient reported a reduction of phantom limb pain for the first time following years of suffering and a complete loss of cramping together with muscle relaxation of the phantom hand. Additionally, we found cortical reorganization in the primary somatosensory cortex (re-reorganization). Strikingly, the relaxed phantom limb together with the reduction of phantom limb pain remained preserved even 6 months after blockade of the brachial plexus. A single temporary blockade of the brachial plexus may relieve phantom limb pain and unpleasant phantom feelings (cramping) for an extended period. Wiley Periodicals, Inc.

  13. Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems.

    Science.gov (United States)

    Boellaard, Ronald; Rausch, Ivo; Beyer, Thomas; Delso, Gaspar; Yaqub, Maqsood; Quick, Harald H; Sattler, Bernhard

    2015-10-01

    Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to -8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.

  14. Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Ronald, E-mail: r.boellaard@vumc.nl [Department of Radiology and Nuclear Medicine, VU Medical Center, Amsterdam 1081 HV (Netherlands); European Association of Nuclear Medicine Research Ltd., Vienna 1060 (Austria); European Association of Nuclear Medicine Physics Committee, Vienna 1060 (Austria); Rausch, Ivo; Beyer, Thomas [Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090 (Austria); Delso, Gaspar [GE Healthcare and University Hospital of Zurich, Zurich 8091 (Switzerland); Yaqub, Maqsood [Department of Radiology and Nuclear Medicine, VU Medical Center, Amsterdam 1081 HV (Netherlands); Quick, Harald H. [Institute of Medical Physics, University of Erlangen-Nuremberg, Erlangen 91052 (Germany); Erwin L. Hahn Institute for MRI, University of Duisburg–Essen, Essen 45141 (Germany); High Field and Hybrid MR-Imaging, University Hospital Essen, Essen 45147 (Germany); Sattler, Bernhard [Department of Nuclear Medicine, University Hospital of Leipzig, Leipzig 04103 (Germany); European Association of Nuclear Medicine Physics Committee, Vienna 1060 (Austria)

    2015-10-15

    Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for

  15. Three-dimensional proton magnetic resonance spectroscopic imaging with and without an endorectal coil: a prostate phantom study.

    Science.gov (United States)

    Ma, Chao; Chen, Luguang; Scheenen, Tom W J; Lu, Jianping; Wang, Jian

    2015-11-01

    Proton magnetic resonance spectroscopic imaging (MRSI) of the prostate has been used with only a combination of external surface coils. The quality of spectral fitting of the (choline + creatine)/citrate ([Cho + Cr]/Cit) ratio at different field strengths and different coils is important for quantitative/semi-quantitative diagnosis of prostate cancer. To evaluate the quality of spectral fitting of the (Cho + Cr)/Cit ratio of a prostate phantom using MRSI at different field strengths and various coils. Experiments were using 1.5-T and 3.0-T MR systems. Measurements were taken on a homemade prostate phantom with different coils: spinal array; abdominal array; and endorectal. The signal-to-noise ratio (SNR) of choline, creatine, and citrate peaks as well as the (Cho + Cr)/Cit ratio in each voxel were compared among groups using multi-way analysis of variance. Magnetic field strength, coils, and plane position had a significant effect on the SNR or (Cho + Cr)/Cit ratio, and there were interactions among groups (all P = 0.000). The 1.5-T (0.228 ± 0.044) exhibited a higher (Cho + Cr)/Cit ratio than the 3.0-T (0.125 ± 0.041) magnetic field strength (F = 3238, P = 0.000). The (Cho + Cr)/Cit ratio of both surface coils (0.183 ± 0.065) and all coils (0.181 ± 0.057) was significantly lower than that of the endorectal coil (0.195 ± 0.077) (both P  0.05). No significant differences were found among the (Cho + Cr)/Cit ratios of all voxels in the middle planes by the post-hoc analyses (all P > 0.05). Three-dimensional proton MRSI of prostate metabolites in a phantom using surface coils is feasible and reliable, but (Cho + Cr)/Cit ratios acquired at different magnetic fields and coils were different. This difference should be taken into account when calculating this ratio in a field strength-independent way. © The Foundation Acta Radiologica 2014.

  16. High frame rate and high line density ultrasound imaging for local pulse wave velocity estimation using motion matching: A feasibility study on vessel phantoms.

    Science.gov (United States)

    Li, Fubing; He, Qiong; Huang, Chengwu; Liu, Ke; Shao, Jinhua; Luo, Jianwen

    2016-04-01

    Pulse wave imaging (PWI) is an ultrasound-based method to visualize the propagation of pulse wave and to quantitatively estimate regional pulse wave velocity (PWV) of the arteries within the imaging field of view (FOV). To guarantee the reliability of PWV measurement, high frame rate imaging is required, which can be achieved by reducing the line density of ultrasound imaging or transmitting plane wave at the expense of spatial resolution and/or signal-to-noise ratio (SNR). In this study, a composite, full-view imaging method using motion matching was proposed with both high temporal and spatial resolution. Ultrasound radiofrequency (RF) data of 4 sub-sectors, each with 34 beams, including a common beam, were acquired successively to achieve a frame rate of ∼507 Hz at an imaging depth of 35 mm. The acceleration profiles of the vessel wall estimated from the common beam were used to reconstruct the full-view (38-mm width, 128-beam) image sequence. The feasibility of mapping local PWV variation along the artery using PWI technique was preliminarily validated on both homogeneous and inhomogeneous polyvinyl alcohol (PVA) cryogel vessel phantoms. Regional PWVs for the three homogeneous phantoms measured by the proposed method were in accordance with the sparse imaging method (38-mm width, 32-beam) and plane wave imaging method. Local PWV was estimated using the above-mentioned three methods on 3 inhomogeneous phantoms, and good agreement was obtained in both the softer (1.91±0.24 m/s, 1.97±0.27 m/s and 1.78±0.28 m/s) and the stiffer region (4.17±0.46 m/s, 3.99±0.53 m/s and 4.27±0.49 m/s) of the phantoms. In addition to the improved spatial resolution, higher precision of local PWV estimation in low SNR circumstances was also obtained by the proposed method as compared with the sparse imaging method. The proposed method might be helpful in disease detections through mapping the local PWV of the vascular wall. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Use of a digital phantom developed by QIBA for harmonizing SUVs obtained from the state-of-the-art SPECT/CT systems: a multicenter study.

    Science.gov (United States)

    Nakahara, Tadaki; Daisaki, Hiromitsu; Yamamoto, Yasushi; Iimori, Takashi; Miyagawa, Kazuyuki; Okamoto, Tomoya; Owaki, Yoshiki; Yada, Nobuhiro; Sawada, Koichi; Tokorodani, Ryotaro; Jinzaki, Masahiro

    2017-12-01

    Although quantitative analysis using standardized uptake value (SUV) becomes realistic in clinical single-photon emission computed tomography/computed tomography (SPECT/CT) imaging, reconstruction parameter settings can deliver different quantitative results among different SPECT/CT systems. This study aims to propose a use of the digital reference object (DRO), which is a National Electrical Manufacturers Association (NEMA) phantom-like object developed by the Quantitative Imaging Biomarker Alliance (QIBA) fluorodeoxyglucose-positron emission tomography technical committee, for the purpose of harmonizing SUVs in Tc-99m SPECT/CT imaging. The NEMA body phantom with determined Tc-99m concentration was scanned with the four state-of-the-art SPECT/CT systems. SPECT data were reconstructed using different numbers of the product of subset and iteration numbers (SI) and the width of 3D Gaussian filter (3DGF). The mean (SUV mean ), maximal (SUV max ), and peak (SUV peak ) SUVs for six hot spheres (10, 13, 17, 22, 28, and 37 mm) were measured after converting SPECT count into SUV using Becquerel calibration factor. DRO smoothed by 3DGF with a FWHM of 17 mm (DRO 17 mm ) was generated, and the corresponding SUVs were measured. The reconstruction condition to yield the lowest root mean square error (RMSE) of SUV means for all the spheres between DRO 17 mm and actual phantom images was determined as the harmonized condition for each SPECT/CT scanner. Then, inter-scanner variability in all quantitative metrics was measured before (i.e., according to the manufacturers' recommendation or the policies of their own departments) and after harmonization. RMSE was lowest in the following reconstruction conditions: SI of 100 and 3DGF of 13 mm for Brightview XCT, SI of 160 and 3DGF of 3 pixels for Discovery NM/CT, SI of 60 and 3DGF of 2 pixels for Infinia, and SI of 140 and 3DGF of 15 mm for Symbia. In pre-harmonized conditions, coefficient of variations (COVs) among the SPECT

  18. Effect of inherent misalignment and head motion in neurological PET/MR with the Philips Ingenuity TF – phantom and patient study

    Energy Technology Data Exchange (ETDEWEB)

    Teuho, Jarmo; Johansson, Jarkko; Saunavaara, Virva; Kemppainen, Nina; Teräs, Mika [Turku PET Centre, Turku University Hospital, Turku (Finland)

    2014-07-29

    The aim of the study was to evaluate the effect of misalignment and head motion on image quantification in PET/MR with a novel brain phantom and a healthy control group. The phantom was imaged at two time points in PET/MR, concurrently with PET and PET/CT. Phantom images were evaluated visually and the relative difference in hemispheric accumulation was calculated. Difference in cortical accumulation in a healthy control group was evaluated from non-attenuation corrected (NAC) and MR attenuation corrected (MRAC) images. Regional ROI mean values from F{sup 18}-FDG ratio images and regional hemispheric asymmetries were calculated. Controls were divided to high and low asymmetry groups. A student’s t-test (p<0.005) for group difference and NAC versus MRAC data was performed. Finally, mean PET-MR registration parameters were measured. Only the first phantom scan exhibited asymmetry in lateral frontal cortex (17%) and temporal cortex (19%). Correcting the misalignment of 2.63mm reduced the asymmetry to less than 5%, to a level seen in PET and PET/CT. A significant asymmetry was found in the temporal and parietal cortex between groups in MRAC data with no significant asymmetry in NAC data. Asymmetries in affected MRAC data in temporal and parietal cortex were 9.4% and 11.7%. NAC data from both groups had asymmetry less than 5% in all regions. Both groups had significant y- and z-translation, while only the asymmetry group had significant z-rotation and x-translation. The shift in x-, y-, or z-direction in both groups was less than 4 mm, with no significant differences. Thus, PET-MRAC misalignment may cause under- and overestimation of attenuation in the lines of response on opposite sides of the cortical regions, resulting to asymmetric difference between the hemispheres. Our findings stress the need for novel QC procedures for PET-MR alignment and suggest confirming the quality of PET-MRAC alignment from PET-NAC images.

  19. Structured movement representations of a phantom limb associated with phantom limb pain.

    Science.gov (United States)

    Osumi, Michihiro; Sumitani, Masahiko; Wake, Naoki; Sano, Yuko; Ichinose, Akimichi; Kumagaya, Shin-Ichiro; Kuniyoshi, Yasuo; Morioka, Shu

    2015-09-25

    The relation between phantom limb pain (PLP) and the movement representation of a phantom limb remains controversial in several areas of neurorehabilitation, although there are a few studies in which the representation of phantom limb movement was precisely evaluated. We evaluated the structured movement representation of a phantom limb objectively using a bimanual circle-line coordination task. We then investigated the relation between PLP and the structured movement representation. Nine patients with a brachial plexus avulsion injury were enrolled who perceived a phantom limb and had neuropathic pain. While blindfolded, the participants repeatedly drew vertical lines using the intact hand and intended to draw circles using the phantom limb simultaneously. "Drawing of circles" by the phantom limb resulted in an oval transfiguration of the vertical lines ("bimanual coupling" effect). We used an arbitrary ovalization index (OI) to quantify the oval transfiguration. When the OI neared 100%, the trajectory changed toward becoming more circular. A significant negative correlation was observed between the intensity of PLP and the OI (r=-0.66, pphantom limb are necessary for alleviating PLP. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Development of thyroid anthropomorphic phantoms for use in nuclear medicine

    Science.gov (United States)

    Cerqueira, R. A. D.; Maia, A. F.

    2014-02-01

    The objective of this study was to develop thyroid anthropomorphic phantoms to be used in control tests of medical images in scintillation cameras. The main difference among the phantoms was the neck shape: in the first, called OSCT, it was geometrically shaped, while in the second, called OSAP, it was anthropomorphically shaped. In both phantoms, thyroid gland prototypes, which were made of acrylic and anthropomorphically shaped, were constructed to allow the simulation of a healthy thyroid and of thyroids with hyperthyroidism and hypothyroidism. Images of these thyroid anthropomorphic phantoms were obtained using iodine 131 with an activity of 8.695 MBq. The iodine 131 was chosen because it is widely used in studies of thyroid scintigraphy. The images obtained proved the effectiveness of the phantoms to simulate normal or abnormal thyroids function. These phantoms can be used in medical imaging quality control programs and, also in the training of professionals involved in the analysis of images in nuclear medicine centers.

  1. SU-E-T-410: Evaluation of Treatment Modalities for Stereotactic Lung Radiation Therapy: A Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Mohatt, D; Malhotra, H [Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: To evaluate and verify the accuracy of alternative treatment modalities for stereotactic lung therapy with end-to-end testing. We compared three dimensional conformal therapy (3DCRT), dynamic conformal arc therapy (DCAT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment using 6 MV, 6 MV flattening filter free (FFF) and 10 MV FFF photons. Methods: A QUASAR respiratory motion phantom was utilized with custom ion chamber and gafchromatic EBT2 film inserts. The phantom contained a low density lung medium with a cylindrical polystyrene tumor (35 cc). Pseudo representative structures for various organs at risk (OAR) were created. All treatment plans were created using Eclipse ver. 11 using the same image and structure sets, and delivered via Varian TrueBeam STx linear accelerator equipped with high definition MLC. Evaluation of plan quality followed ROTG 0813 criterion for conformity index (CI100%), high dose spillage, D2cm, and R50%. Results: All treatment plans met the OAR dose constraints per protocol and could be delivered without any beam hold offs or other interlocks and hence were deemed clinically safe. For equivalent beam energies, target conformity was improved for all modalities when switching to FFF mode. Treatment efficiency increased for VMAT FFF by a factor of 3–4 over IMRT, and up to factor of 7 when compared to 3DCRT. Pass rates were > 97% for all treatment using gamma criteria of 3%, 3mm. Absolute dose at iso-center was verified with ion chamber, and found to be within 2% of the treatment planning system. Conclusion: The higher dose rate associated with FFF not only reduces delivery times, but in most cases enhances plan quality. The one modality with succeeding best results for all RTOG criterions was VMAT 6 MV FFF. This end-to-end testing provides necessary confidence in the entire dose delivery chain for lung SBRT patients.

  2. Comparison of conventional ultrasonography and ultrasonography-computed tomography fusion imaging for target identification using digital/real hybrid phantoms: a preliminary study.

    Science.gov (United States)

    Soyama, Takeshi; Sakuhara, Yusuke; Kudo, Kohsuke; Abo, Daisuke; Wang, Jeff; Ito, Yoichi M; Hasegawa, Yu; Shirato, Hiroki

    2016-07-01

    This preliminary study compared ultrasonography-computed tomography (US-CT) fusion imaging and conventional ultrasonography (US) for accuracy and time required for target identification using a combination of real phantoms and sets of digitally modified computed tomography (CT) images (digital/real hybrid phantoms). In this randomized prospective study, 27 spheres visible on B-mode US were placed at depths of 3.5, 8.5, and 13.5 cm (nine spheres each). All 27 spheres were digitally erased from the CT images, and a radiopaque sphere was digitally placed at each of the 27 locations to create 27 different sets of CT images. Twenty clinicians were instructed to identify the sphere target using US alone and fusion imaging. The accuracy of target identification of the two methods was compared using McNemar's test. The mean time required for target identification and error distances were compared using paired t tests. At all three depths, target identification was more accurate and the mean time required for target identification was significantly less with US-CT fusion imaging than with US alone, and the mean error distances were also shorter with US-CT fusion imaging. US-CT fusion imaging was superior to US alone in terms of accurate and rapid identification of target lesions.

  3. Quantitative investigation of the edge enhancement in in-line phase contrast projections and tomosynthesis provided by distributing microbubbles on the interface between two tissues: a phantom study

    Science.gov (United States)

    Wu, Di; Donovan Wong, Molly; Li, Yuhua; Fajardo, Laurie; Zheng, Bin; Wu, Xizeng; Liu, Hong

    2017-12-01

    The objective of this study was to quantitatively investigate the ability to distribute microbubbles along the interface between two tissues, in an effort to improve the edge and/or boundary features in phase contrast imaging. The experiments were conducted by employing a custom designed tissue simulating phantom, which also simulated a clinical condition where the ligand-targeted microbubbles are self-aggregated on the endothelium of blood vessels surrounding malignant cells. Four different concentrations of microbubble suspensions were injected into the phantom: 0%, 0.1%, 0.2%, and 0.4%. A time delay of 5 min was implemented before image acquisition to allow the microbubbles to become distributed at the interface between the acrylic and the cavity simulating a blood vessel segment. For comparison purposes, images were acquired using three system configurations for both projection and tomosynthesis imaging with a fixed radiation dose delivery: conventional low-energy contact mode, low-energy in-line phase contrast and high-energy in-line phase contrast. The resultant images illustrate the edge feature enhancements in the in-line phase contrast imaging mode when the microbubble concentration is extremely low. The quantitative edge-enhancement-to-noise ratio calculations not only agree with the direct image observations, but also indicate that the edge feature enhancement can be improved by increasing the microbubble concentration. In addition, high-energy in-line phase contrast imaging provided better performance in detecting low-concentration microbubble distributions.

  4. Evaluation of dosimetry and image of very low-dose computed tomography attenuation correction for pediatric positron emission tomography/computed tomography: phantom study

    Science.gov (United States)

    Bahn, Y. K.; Park, H. H.; Lee, C. H.; Kim, H. S.; Lyu, K. Y.; Dong, K. R.; Chung, W. K.; Cho, J. H.

    2014-04-01

    In this study, phantom was used to evaluate attenuation correction computed tomography (CT) dose and image in case of pediatric positron emission tomography (PET)/CT scan. Three PET/CT scanners were used along with acryl phantom in the size for infant and ion-chamber dosimeter. The CT image acquisition conditions were changed from 10 to 20, 40, 80, 100 and 160 mA and from 80 to 100, 120 and 140 kVp, which aimed at evaluating penetrate dose and computed tomography dose indexvolume (CTDIvol) value. And NEMA PET Phantom™ was used to obtain PET image under the same CT conditions in order to evaluate each attenuation-corrected PET image based on standard uptake value (SUV) value and signal-to-noise ratio (SNR). In general, the penetrate dose was reduced by around 92% under the minimum CT conditions (80 kVp and 10 mA) with the decrease in CTDIvol value by around 88%, compared with the pediatric abdomen CT conditions (100 kVp and 100 mA). The PET image with its attenuation corrected according to each CT condition showed no change in SUV value and no influence on the SNR. In conclusion, if the minimum dose CT that is properly applied to body of pediatric patient is corrected for attenuation to ensure that the effective dose is reduced by around 90% or more compared with that for adult patient, this will be useful to reduce radiation exposure level.

  5. Navigation of a robot-integrated fluorescence laparoscope in preoperative SPECT/CT and intraoperative freehand SPECT imaging data: a phantom study

    Science.gov (United States)

    van Oosterom, Matthias Nathanaël; Engelen, Myrthe Adriana; van den Berg, Nynke Sjoerdtje; KleinJan, Gijs Hendrik; van der Poel, Henk Gerrit; Wendler, Thomas; van de Velde, Cornelis Jan Hadde; Navab, Nassir; van Leeuwen, Fijs Willem Bernhard

    2016-08-01

    Robot-assisted laparoscopic surgery is becoming an established technique for prostatectomy and is increasingly being explored for other types of cancer. Linking intraoperative imaging techniques, such as fluorescence guidance, with the three-dimensional insights provided by preoperative imaging remains a challenge. Navigation technologies may provide a solution, especially when directly linked to both the robotic setup and the fluorescence laparoscope. We evaluated the feasibility of such a setup. Preoperative single-photon emission computed tomography/X-ray computed tomography (SPECT/CT) or intraoperative freehand SPECT (fhSPECT) scans were used to navigate an optically tracked robot-integrated fluorescence laparoscope via an augmented reality overlay in the laparoscopic video feed. The navigation accuracy was evaluated in soft tissue phantoms, followed by studies in a human-like torso phantom. Navigation accuracies found for SPECT/CT-based navigation were 2.25 mm (coronal) and 2.08 mm (sagittal). For fhSPECT-based navigation, these were 1.92 mm (coronal) and 2.83 mm (sagittal). All errors remained below the surgery procedures.

  6. Tissue-like phantoms

    Science.gov (United States)

    Frangioni, John V.; De Grand, Alec M.

    2007-10-30

    The invention is based, in part, on the discovery that by combining certain components one can generate a tissue-like phantom that mimics any desired tissue, is simple and inexpensive to prepare, and is stable over many weeks or months. In addition, new multi-modal imaging objects (e.g., beads) can be inserted into the phantoms to mimic tissue pathologies, such as cancer, or merely to serve as calibration standards. These objects can be imaged using one, two, or more (e.g., four) different imaging modalities (e.g., x-ray computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), and near-infrared (NIR) fluorescence) simultaneously.

  7. Low-dose single acquisition rest {sup 99m}Tc/stress {sup 201}Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Thomas [RWTH Aachen University, Institute of Imaging and Computer Vision, Aachen (Germany); Backus, Barbra E.; Romijn, R.Leo [St. Antonius Hospital, Department of Nuclear Medicine, Nieuwegein (Netherlands); Wieczorek, Herfried [Philips Research, Eindhoven (Netherlands); Verzijlbergen, J.F. [St. Antonius Hospital, Department of Nuclear Medicine, Nieuwegein (Netherlands); Erasmus Medical Center, Department of Nuclear Medicine, Rotterdam (Netherlands)

    2014-03-15

    We developed and tested a single acquisition rest {sup 99m}Tc-sestamibi/stress {sup 201}Tl dual isotope protocol (SDI) with the intention of improving the clinical workflow and patient comfort of myocardial perfusion single photon emission computed tomography (SPECT). The technical feasibility of SDI was evaluated by a series of anthropomorphic phantom studies on a standard SPECT camera. The attenuation map was created by a moving transmission line source. Iterative reconstruction including attenuation correction, resolution recovery and Monte Carlo simulation of scatter was used for simultaneous reconstruction of dual tracer distribution. For clinical evaluation, patient studies were compared to stress {sup 99m}Tc and rest {sup 99m}Tc reference images acquired in a 2-day protocol. Clinical follow-up examinations like coronary angiography (CAG) and fractional flow reserve (FFR) were included in the assessment if available. Phantom studies demonstrated the technical feasibility of SDI. Artificial lesions inserted in the phantom mimicking ischaemia could be clearly identified. In 51/53 patients, the image quality was adequate for clinical evaluation. For the remaining two obese patients with body mass index > 32 the injected {sup 201}Tl dose of 74 MBq was insufficient for clinical assessment. In answer to this the {sup 201}Tl dose was adapted for obese patients in the rest of the study. In 31 patients, SDI and {sup 99m}Tc reference images resulted in equivalent clinical assessment. Significant differences were found in 20 patients. In 18 of these 20 patients additional examinations were available. In 15 patients the diagnosis based on the SDI images was confirmed by the results of CAG or FFR. In these patients the SDI images were more accurate than the {sup 99m}Tc reference study. In three patients minor ischaemic lesions were detected by SDI but were not confirmed by CAG. In one of these cases this was probably caused by pronounced apical thinning. For two patients

  8. Phantom Eye Syndrome: A Review of the Literature

    Directory of Open Access Journals (Sweden)

    Agda M. Andreotti

    2014-01-01

    Full Text Available The purpose of this literature review was to describe the main features of phantom eye syndrome in relation to their possible causes, symptoms, treatments, and influence of eye amputation on quality of life of anophthalmic patients. For this, a bibliographical research was performed in Pubmed database using the following terms: “eye amputation,” “eye trauma,” “phantom eye syndrome,” “phantom pain,” and “quality of life,” associated or not. Thirteen studies were selected, besides some relevant references contained in the selected manuscripts and other studies hallowed in the literature. Thus, 56 articles were included in this review. The phantom eye syndrome is defined as any sensation reported by the patient with anophthalmia, originated anophthalmic cavity. In phantom eye syndrome, at least one of these three symptoms has to be present: phantom vision, phantom pain, and phantom sensations. This syndrome has a direct influence on the quality of life of the patients, and psychological support is recommended before and after the amputation of the eyeball as well as aid in the treatment of the syndrome. Therefore, it is suggested that, for more effective treatment of phantom eye syndrome, drug therapy should be associated with psychological approach.

  9. Deep Inspiration Breath Hold [(18)F]FDG PET-CT on 4-rings scanners in evaluating lung lesions: evidences from a phantom and a clinical study.

    Science.gov (United States)

    Caobelli, Federico; Puta, Erinda; Kaiser, Stefano Ren; Massetti, Valentina; Andreoli, Michela; Mostarda, Angelica; Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo

    2014-01-01

    To investigate the clinical feasibility of a Deep Inspiration Breath Hold (DIBH) (18)F-FDG PET-CT acquisition in apnea and compare the results obtained between these acts of acquisition in apnea and in Free Breathing in the evaluation of lung lesions. A pre-clinical phantom study was performed to evaluate the shortest simulated DIBH time according to the minimum detectable lesion that can be detected by our ultrasound scanner. This study was conducted by changing acquisition time and sphere-to-background activity ratio values and by using radioactivity densities similar to those generally found in clinical examinations. In the clinical study, 25 patients with pulmonary lesions underwent a standard whole body (18)F-FDG PET-CT scan in free breathing followed by a 20s single thorax acquisition PET/CT in DIBH acquisition. The phantom study indicated that a 20-s acquisition time provides an accurate evaluation of smallest sphere shaped lesions. In the clinical study, PET-CT scans obtained in DIBH studies showed a significant reduction of misalignment between the PET and CT scan images and an increase of SUVmax compared to free breathing acquisitions. A correlation between the %BH-index and lesion displacement between PET and CT images in FB acquisition was demonstrated, significantly higher for lesions with a displacement>8mm. The single 20s acquisition of DIBH PET-CT is a feasible technique for lung lesion detection in the clinical setting. It only requires a minor increase in examination time without special patient training. 20s DIBH scan provided a more precise measurement of SUVmax, especially for lesions in the lower lung lobes which usually show greater displacement between PET and CT scan images in FB acquisition. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  10. Evaluation of a BGO-Based PET System for Single-Cell Tracking Performance by Simulation and Phantom Studies

    Directory of Open Access Journals (Sweden)

    Yu Ouyang PhD

    2016-05-01

    Full Text Available A recent method based on positron emission was reported for tracking moving point sources using the Inveon PET system. However, the effect of scanner background noise was not further explored. Here, we evaluate tracking with the Genisys4, a bismuth germanate-based PET system, which has no significant intrinsic background and may be better suited to tracking lower and/or faster activity sources. Position-dependent sensitivity of the Genisys4 was simulated in Geant4 Application for Tomographic Emission (GATE using a static 18F point source. Trajectories of helically moving point sources with varying activity and rotation speed were reconstructed from list-mode data as described previously. Simulations showed that the Inveon’s ability to track sources within 2 mm of localization error is limited to objects with a velocity-to-activity ratio < 0.13 mm/decay, compared to < 0.29 mm/decay for the Genisys4. Tracking with the Genisys4 was then validated using a physical phantom of helically moving [18F] fluorodeoxyglucose-in-oil droplets (< 0.24 mm diameter, 139-296 Bq, yielding < 1 mm localization error under the tested conditions, with good agreement between simulated sensitivity and measured activity (Pearson correlation R = .64, P << .05 in a representative example. We have investigated the tracking performance with the Genisys4, and results suggest the feasibility of tracking low activity, point source-like objects with this system.

  11. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Qu, Mingliang; Duan, Xinhui; Takahashi, Naoki; Kawashima, Akira; Leng, Shuai; McCollough, Cynthia H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2012-12-15

    To develop a dual-energy CT (DECT) method for differentiating uric acid (UA) from non-UA stones in the presence of iodinated contrast medium. Thirty UA and 45 non-UA stones were selected after infra-red spectroscopic analysis and independently placed in a 1.5-ml vial, which was filled first with saline and then with increasing concentrations of iodine. For each condition, tubes were put in a 35-cm water phantom and examined using a dual-source CT system at 100 and 140 kV. Virtual unenhanced images created from CT data sets of the stones in iodine-containing solutions provided position and volume information. This map was used to calculate a CT number ratio to differentiate stone type. A region-growing method was developed to improve the ability to differentiate between UA and non-UA stones with iodinated contrast medium. The sensitivity for detecting UA stones was 100 % for unenhanced images but fell to 18 % with 20 mgI/ml iodine solution and 0 % for higher concentrations. With region growing, the sensitivity for detecting UA stones was increased to 100 %, 82 %, 57 %, 50 % and 21 % for iodine solutions of 20, 40, 60, 80 and 100 mgI/ml. The region-growing method improves differentiation of UA from non-UA stones on contrast-enhanced DECT urograms. (orig.)

  12. Detecting breast microcalcifications using super-resolution and wave-equation ultrasound imaging: a numerical phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Simonetti, Francesco [IMPERIAL COLLEGE LONDON; Huthwaite, Peter [IMPERIAL COLLEGE LONDON; Rosenberg, Robert [UNM; Williamson, Michael [UNM

    2010-01-01

    Ultrasound image resolution and quality need to be significantly improved for breast microcalcification detection. Super-resolution imaging with the factorization method has recently been developed as a promising tool to break through the resolution limit of conventional imaging. In addition, wave-equation reflection imaging has become an effective method to reduce image speckles by properly handling ultrasound scattering/diffraction from breast heterogeneities during image reconstruction. We explore the capabilities of a novel super-resolution ultrasound imaging method and a wave-equation reflection imaging scheme for detecting breast microcalcifications. Super-resolution imaging uses the singular value decomposition and a factorization scheme to achieve an image resolution that is not possible for conventional ultrasound imaging. Wave-equation reflection imaging employs a solution to the acoustic-wave equation in heterogeneous media to backpropagate ultrasound scattering/diffraction waves to scatters and form images of heterogeneities. We construct numerical breast phantoms using in vivo breast images, and use a finite-difference wave-equation scheme to generate ultrasound data scattered from inclusions that mimic microcalcifications. We demonstrate that microcalcifications can be detected at full spatial resolution using the super-resolution ultrasound imaging and wave-equation reflection imaging methods.

  13. In vitro toxicology studies of extracellular vesicles.

    Science.gov (United States)

    Maji, Sayantan; Yan, Irene K; Parasramka, Mansi; Mohankumar, Swathi; Matsuda, Akiko; Patel, Tushar

    2017-03-01

    Extracellular vesicles (EVs) are membrane-bound vesicles released from cells into the extracellular environment. There is emerging interest in the use of EVs as potential therapeutic interventions. We sought to evaluate the safety of EVs that may be therapeutically used by performing in vitro toxicological assessments. EVs were obtained from mesenchymal stem cells (MSC-EV) or from bovine milk (BM-EV) by differential ultracentrifugation, and quantitated using nanoparticle tracking analysis. Genotoxic effects, hematological effects, immunological effects and endotoxin production were evaluated at two dose levels. Neither MSC-EVs nor BM-EVs elicited detectable genotoxic effects using either the alkaline comet assay or micronucleus assay. Hemolysis was observed with BM-EVs but not with MSC-EVs. MSC-EVs did not have any significant effect on either spontaneous or collagen-induced platelet aggregation. In contrast, BM-EVs were noted to increase collagen-induced platelet aggregation, even though no spontaneous increase in platelet aggregation was noted. Both types of EVs induced leukocyte proliferation, which was greater with BM-EV. Neither MSC-EVs nor BM-EVs induced HL-60 phagocytosis, although BM-EVs decreased zymosan-induced phagocytosis. Furthermore, neither MSC-EVs nor BM-EVs induced nitric oxide production. Unlike MSC-EVs, BM-EVs tested positive for endotoxin and induced complement activation. There are significant differences in toxicological profiles between MSC-EVs and BM-EVs that may reflect variations in techniques for EV isolation, EV content or cross-species differences. The safety of MSC-EV supports their use for disease therapeutics, whereas detailed safety and toxicological assessment will be necessary before the use of BM-EVs. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Integration of a real-time tumor monitoring system into gated proton spot-scanning beam therapy: an initial phantom study using patient tumor trajectory data.

    Science.gov (United States)

    Matsuura, Taeko; Miyamoto, Naoki; Shimizu, Shinichi; Fujii, Yusuke; Umezawa, Masumi; Takao, Seishin; Nihongi, Hideaki; Toramatsu, Chie; Sutherland, Kenneth; Suzuki, Ryusuke; Ishikawa, Masayori; Kinoshita, Rumiko; Maeda, Kenichiro; Umegaki, Kikuo; Shirato, Hiroki

    2013-07-01

    In spot-scanning proton therapy, the interplay effect between tumor motion and beam delivery leads to deterioration of the dose distribution. To mitigate the impact of tumor motion, gating in combination with repainting is one of the most promising methods that have been proposed. This study focused on a synchrotron-based spot-scanning proton therapy system integrated with real-time tumor monitoring. The authors investigated the effectiveness of gating in terms of both the delivered dose distribution and irradiation time by conducting simulations with patients' motion data. The clinically acceptable range of adjustable irradiation control parameters was explored. Also, the relation between the dose error and the characteristics of tumor motion was investigated. A simulation study was performed using a water phantom. A gated proton beam was irradiated to a clinical target volume (CTV) of 5 × 5 × 5 cm(3), in synchronization with lung cancer patients' tumor trajectory data. With varying parameters of gate width, spot spacing, and delivered dose per spot at one time, both dose uniformity and irradiation time were calculated for 397 tumor trajectory data from 78 patients. In addition, the authors placed an energy absorber upstream of the phantom and varied the thickness to examine the effect of changing the size of the Bragg peak and the number of required energy layers. The parameters with which 95% of the tumor trajectory data fulfill our defined criteria were accepted. Next, correlation coefficients were calculated between the maximum dose error and the tumor motion characteristics that were extracted from the tumor trajectory data. With the assumed CTV, the largest percentage of the data fulfilled the criteria when the gate width was ± 2 mm. Larger spot spacing was preferred because it increased the number of paintings. With a prescribed dose of 2 Gy, it was difficult to fulfill the criteria for the target with a very small effective depth (the sum of an assumed

  15. Determining the Minimal Required Radioactivity of 18F-FDG for Reliable Semiquantification in PET/CT Imaging: A Phantom Study.

    Science.gov (United States)

    Chen, Ming-Kai; Menard, David H; Cheng, David W

    2016-03-01

    In pursuit of as-low-as-reasonably-achievable (ALARA) doses, this study investigated the minimal required radioactivity and corresponding imaging time for reliable semiquantification in PET/CT imaging. Using a phantom containing spheres of various diameters (3.4, 2.1, 1.5, 1.2, and 1.0 cm) filled with a fixed (18)F-FDG concentration of 165 kBq/mL and a background concentration of 23.3 kBq/mL, we performed PET/CT at multiple time points over 20 h of radioactive decay. The images were acquired for 10 min at a single bed position for each of 10 half-lives of decay using 3-dimensional list mode and were reconstructed into 1-, 2-, 3-, 4-, 5-, and 10-min acquisitions per bed position using an ordered-subsets expectation maximum algorithm with 24 subsets and 2 iterations and a gaussian 2-mm filter. SUVmax and SUVavg were measured for each sphere. The minimal required activity (±10%) for precise SUVmax semiquantification in the spheres was 1.8 kBq/mL for an acquisition of 10 min, 3.7 kBq/mL for 3-5 min, 7.9 kBq/mL for 2 min, and 17.4 kBq/mL for 1 min. The minimal required activity concentration-acquisition time product per bed position was 10-15 kBq/mL⋅min for reproducible SUV measurements within the spheres without overestimation. Using the total radioactivity and counting rate from the entire phantom, we found that the minimal required total activity-time product was 17 MBq⋅min and the minimal required counting rate-time product was 100 kcps⋅min. Our phantom study determined a threshold for minimal radioactivity and acquisition time for precise semiquantification in (18)F-FDG PET imaging that can serve as a guide in pursuit of achieving ALARA doses. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. The usefulness of mobile insulator sheets for the optimisation of deep heating area for regional hyperthermia using a capacitively coupled heating method: phantom, simulation and clinical prospective studies.

    Science.gov (United States)

    Tomura, Kyosuke; Ohguri, Takayuki; Mulder, Hendrik Thijmen; Murakami, Motohiro; Nakahara, Sota; Yahara, Katsuya; Korogi, Yukunori

    2017-11-20

    To evaluate the feasibility and efficacy of deep regional hyperthermia with the use of mobile insulator sheets in a capacitively coupled heating device. The heat was applied using an 8-MHz radiofrequency-capacitive device. The insulator sheet was inserted between the regular bolus and cooled overlay bolus in each of upper and lower side of the electrode. Several settings using the insulator sheets were investigated in an experimental study using an agar phantom to evaluate the temperature distributions. The specific absorption rate (SAR) distributions in several organs were also computed for the three-dimensional patient model. In a clinical prospective study, a total of five heating sessions were scheduled for the pelvic tumours, to assess the thermal parameters. The conventional setting was used during the first, third and fifth treatment sessions, and insulator sheets were used during the second and fourth treatment sessions. In the phantom study, the higher heating area improved towards the centre when the mobile insulator sheets were used. The subcutaneous fat/target ratios for the averaged SARs in the setting with the mobile insulator (median, 2.5) were significantly improved compared with those in the conventional setting (median, 3.4). In the clinical study, the thermal dose parameters of CEM43°CT90 in the sessions with the mobile insulator sheets (median, 1.9 min) were significantly better than those in the sessions using a conventional setting (median, 1.0 min). Our novel heating method using mobile insulator sheets was thus found to improve the thermal dose parameters. Further investigations are expected.

  17. Survey of phantom limb pain, phantom sensation and stump pain in Cambodian and New Zealand amputees.

    Science.gov (United States)

    Byrne, Kelly Patrick Anthony

    2011-05-01

    The primary objective of this study is to compare the prevalence of phantom limb pain in New Zealand and Cambodian amputees and to assess the demographics of a sample of amputees from these two countries. All participants were interviewed using a 12-question survey that covered demographic data and reason for amputation and assessed the presence of phantom limb sensation, phantom limb pain, and stump pain. Amputees attending an artificial limb center in Cambodia were approached and interviewed in person. New Zealand amputees attending the Waikato artificial limb center were randomly selected and interviewed by phone. There was no statistically significant difference in phantom limb sensation, phantom limb pain, or stump pain between the two groups. There was a much higher unemployment rate in the Cambodian amputees. There were no other statistically significant differences between the groups Despite very different environments, there was no difference in the phantom limb pain between the groups. One possible explanation is that the severity of neurological injury associated with amputation overrides all the other risk factors that influence the development of other chronic pain syndromes. Wiley Periodicals, Inc.

  18. The Phantom of Liberty

    DEFF Research Database (Denmark)

    One of the few things we have in common in contemporary society is the future of our children. But it seems that even the “we” of childhood, of learning and free play, has turned into a common ground for instrumentalization and competition. Today, the pedagogical paradox—Kant’s meditation on the ......? These are some of the questions addressed by The Phantom of Liberty, which sets out to reestablish a social and aesthetic dialogue between visual art and psychology, philosophy, pedagogy, and critical journalism....

  19. A Dirichlet process mixture model for automatic {sup 18}F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giri, Maria Grazia, E-mail: mariagrazia.giri@ospedaleuniverona.it; Cavedon, Carlo [Medical Physics Unit, University Hospital of Verona, P.le Stefani 1, Verona 37126 (Italy); Mazzarotto, Renzo [Radiation Oncology Unit, University Hospital of Verona, P.le Stefani 1, Verona 37126 (Italy); Ferdeghini, Marco [Nuclear Medicine Unit, University Hospital of Verona, P.le Stefani 1, Verona 37126 (Italy)

    2016-05-15

    Purpose: The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robustness. Methods: The DPM model belongs to the class of the Bayesian nonparametric models and uses the Dirichlet process prior for flexible nonparametric mixture modeling, without any preliminary choice of the number of mixture components. The DPM algorithm implemented in the statistical software package R was used in this work. The contouring accuracy was evaluated on several image data sets: on an IEC phantom (spherical inserts with diameter in the range 10–37 mm) acquired by a Philips Gemini Big Bore PET-CT scanner, using 9 different target-to-background ratios (TBRs) from 2.5 to 70; on a digital phantom simulating spherical/uniform lesions and tumors, irregular in shape and activity; and on 20 clinical cases (10 lung and 10 esophageal cancer patients). The influence of the DPM parameters on contour generation was studied in two steps. In the first one, only the IEC spheres having diameters of 22 and 37 mm and a sphere of the digital phantom (41.6 mm diameter) were studied by varying the main parameters until the diameter of the spheres was obtained within 0.2% of the true value. In the second step, the results obtained for this training set were applied to the entire data set to determine DPM based volumes of all available lesions. These volumes were compared to those obtained by applying already known algorithms (Gaussian mixture model and gradient-based) and to true values, when available. Results: Only one parameter was found able to significantly influence segmentation accuracy (ANOVA test). This parameter was linearly connected to the uptake variance of the tested region of interest (ROI). In the first step of the study, a

  20. A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.

    Science.gov (United States)

    Giri, Maria Grazia; Cavedon, Carlo; Mazzarotto, Renzo; Ferdeghini, Marco

    2016-05-01

    The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robustness. The DPM model belongs to the class of the Bayesian nonparametric models and uses the Dirichlet process prior for flexible nonparametric mixture modeling, without any preliminary choice of the number of mixture components. The DPM algorithm implemented in the statistical software package R was used in this work. The contouring accuracy was evaluated on several image data sets: on an IEC phantom (spherical inserts with diameter in the range 10-37 mm) acquired by a Philips Gemini Big Bore PET-CT scanner, using 9 different target-to-background ratios (TBRs) from 2.5 to 70; on a digital phantom simulating spherical/uniform lesions and tumors, irregular in shape and activity; and on 20 clinical cases (10 lung and 10 esophageal cancer patients). The influence of the DPM parameters on contour generation was studied in two steps. In the first one, only the IEC spheres having diameters of 22 and 37 mm and a sphere of the digital phantom (41.6 mm diameter) were studied by varying the main parameters until the diameter of the spheres was obtained within 0.2% of the true value. In the second step, the results obtained for this training set were applied to the entire data set to determine DPM based volumes of all available lesions. These volumes were compared to those obtained by applying already known algorithms (Gaussian mixture model and gradient-based) and to true values, when available. Only one parameter was found able to significantly influence segmentation accuracy (ANOVA test). This parameter was linearly connected to the uptake variance of the tested region of interest (ROI). In the first step of the study, a calibration curve was determined to

  1. Cosmological perturbations in transient phantom inflation scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Richarte, Martin G. [Universidade Federal do Parana, Departamento de Fisica, Caixa Postal 19044, Curitiba (Brazil); Universidad de Buenos Aires, Ciudad Universitaria 1428, Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Buenos Aires (Argentina); Kremer, Gilberto M. [Universidade Federal do Parana, Departamento de Fisica, Caixa Postal 19044, Curitiba (Brazil)

    2017-01-15

    We present a model of inflation where the inflaton is accommodated as a phantom field which exhibits an initial transient pole behavior and then decays into a quintessence field which is responsible for a radiation era. We must stress that the present unified model only deals with a single field and that the transition between the two eras is achieved in a smooth way, so the model does not suffer from the eternal inflation issue. We explore the conditions for the crossing of the phantom divide line within the inflationary era along with the structural stability of several critical points. We study the behavior of the phantom field within the slow-climb approximation along with the necessary conditions to have sufficient inflation. We also examine the model at the level of classical perturbations within the Newtonian gauge and determine the behavior of the gravitational potential, contrast density and perturbed field near the inflation stage and the subsequent radiation era. (orig.)

  2. Photoacoustic investigation of a neonatal skull phantom

    Science.gov (United States)

    Volinski, Bridget; Hariri, Ali; Fatima, Afreen; Xu, Qiuyun; Nasiriavanaki, Mohammadreza

    2017-03-01

    There is a need for continued research into the diagnosis, prevention and cure of neonatal brain disease and disorders. These disorders lead to fatalities and developmental disorders in infants. Non-invasive imaging techniques are being researched for this purpose. However, the availability of neonatal skull samples for this work is very low. A phantom can be used to simulate the neonatal skull and brain to improve imaging techniques. This study selects a phantom of polyurethane and titanium dioxide and proves its value as a replacement for neonatal skull in research. The methods used for this proof are validation of choice against the literature, transmissivity and acoustic experimentation compared to existing literature, and finally photoacoustic evaluation of the final choice to show its usefulness as a neonatal skull phantom.

  3. Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Akinori; Yanagawa, Masahiro; Honda, Osamu; Gyobu, Tomoko; Ueda, Ken; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan)

    2016-12-15

    To assess image quality of filtered back-projection (FBP) and model-based iterative reconstruction (MBIR) with a conventional setting and a new lung-specific setting on submillisievert CT. A lung phantom with artificial nodules was scanned with 10 mA at 120 kVp and 80 kVp (0.14 mSv and 0.05 mSv, respectively); images were reconstructed using FBP and MBIR with conventional setting (MBIR{sub Stnd}) and lung-specific settings (MBIR{sub RP20/Tx} and MBIR{sub RP20}). Three observers subjectively scored overall image quality and image findings on a 5-point scale (1 = worst, 5 = best) compared with reference standard images (50 mA-FBP at 120, 100, 80 kVp). Image noise was measured objectively. MBIR{sub RP20/Tx} performed significantly better than MBIR{sub Stnd} for overall image quality in 80-kVp images (p < 0.01), blurring of the border between lung and chest wall in 120p-kVp images (p < 0.05) and the ventral area of 80-kVp images (p < 0.001), and clarity of small vessels in the ventral area of 80-kVp images (p = 0.037). At 120 kVp, 10 mA-MBIR{sub RP20} and 10 mA-MBIR{sub RP20/Tx} showed similar performance to 50 mA-FBP. MBIR{sub Stnd} was better for noise reduction. Except for blurring in 120 kVp-MBIR{sub Stnd}, MBIRs performed better than FBP. Although a conventional setting was advantageous in noise reduction, a lung-specific setting can provide more appropriate image quality, even on submillisievert CT. (orig.)

  4. Impact of radiation dose and iterative reconstruction on pulmonary nodule measurements at chest CT: a phantom study

    Science.gov (United States)

    Kim, Hyungjin; Min Park, Chang; Chae, Hee-Dong; Lee, Sang Min; Goo, Jin Mo

    2015-01-01

    PURPOSE We aimed to identify the impact of radiation dose and iterative reconstruction (IR) on measurement of pulmonary nodules by chest computed tomography (CT). METHODS CT scans were performed on a chest phantom containing various nodules (diameters of 3, 5, 8, 10, and 12 mm; +100, −630 and −800 HU for each diameter) at 80, 100, 120 kVp and 10, 20, 50, 100 mAs (a total of 12 radiation dose settings). Each CT was reconstructed using filtered back projection, iDose4, and iterative model reconstruction (IMR). Thereafter, two radiologists measured the diameter and attenuation of the nodules. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. Influence of radiation dose and reconstruction algorithm on measurement error and objective image quality metrics was analyzed using generalized estimating equations. RESULTS The 80 kVp, 10 mAs CT scan was not feasible for the measurement of 3 mm sized simulated ground-glass nodule (GGN); otherwise, diameter measurement error was not significantly influenced by radiation dose (P > 0.05). IR did not have a significant impact on diameter measurement error for simulated solid nodules (P > 0.05). However, for simulated GGNs, IMR was associated with significantly decreased relative diameter measurement error (P reconstruction algorithm (P > 0.05). Objective image quality was significantly better with IMR (P < 0.05). CONCLUSION Nodule measurements were not affected by radiation dose except for 3 mm simulated GGN on 80 kVp, 10 mAs dose setting. However, for GGNs, IMR may help reduce diameter measurement error while improving image quality. PMID:26359871

  5. In Vitro Study of Release of Metronidazole Tablets Prepared from ...

    African Journals Online (AJOL)

    The aim of this study is to evaluate the ability of okra gum to release it\\'s medicament in bioadhesive polymer-based drug delivery system. Bioadhesive studies using the tensiometer were done to evaluate its bioadhesivenes. Conventional tablets were made with okra gum as binder and in-vitro release studies carried out ...

  6. Biomechanical rationale for a single implant-retained mandibular overdenture: an in vitro study.

    Science.gov (United States)

    Maeda, Yoshinobu; Horisaka, Mitsuhiro; Yagi, Kaztomo

    2008-03-01

    This study aimed to examine the biomechanical rationale of a single implant-retained overdenture (SIO) system using an in vitro model. Laboratory implant analogs (3.75 x 13 mm) were embedded into the midline and canine regions on both sides of the mandibular phantom model with artificial mucosa. Magnetic attachments (flat, FM; dome, DM) and a ball attachment (Ball) were mounted to the abutment where lateral forces were measured with four miniature strain gauges attached to the surface. A 50 N static load was applied at five different sites of the occlusal surface of the simulated denture base using each counterpart of the attachments. Strain data were compared between SIO and two implant-retained configurations (TIO) with three attachments. Three-dimensional (3D) denture base displacements were also measured. Statistical analysis was performed by multiple comparisons using a post hoc test (P<0.05). Statistically significantly smaller lateral forces to abutments were obtained in SIO than in TIO with the Ball with the molar load, while there were no statistical differences between SIO and TIO with FM. There were no statistical differences in 3D denture base movements between SIO and TIO in the midline and molar regions, while there were larger movements in SIO than in TIO with FM. Within the limitations of our in vitro study, we suggested that single-implant overdentures with dome-type magnet or ball attachments had biomechanical effects similar to two-implant overdentures in terms of lateral forces to the abutment and denture base movements under molar functional loads.

  7. Multi-Modality Phantom Development

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Peng, Qiyu; Moses, William W.

    2009-03-20

    Multi-modality imaging has an increasing role in the diagnosis and treatment of a large number of diseases, particularly if both functional and anatomical information are acquired and accurately co-registered. Hence, there is a resulting need for multi modality phantoms in order to validate image co-registration and calibrate the imaging systems. We present our PET-ultrasound phantom development, including PET and ultrasound images of a simple prostate phantom. We use agar and gelatin mixed with a radioactive solution. We also present our development of custom multi-modality phantoms that are compatible with PET, transrectal ultrasound (TRUS), MRI and CT imaging. We describe both our selection of tissue mimicking materials and phantom construction procedures. These custom PET-TRUS-CT-MRI prostate phantoms use agargelatin radioactive mixtures with additional contrast agents and preservatives. We show multi-modality images of these custom prostate phantoms, as well as discuss phantom construction alternatives. Although we are currently focused on prostate imaging, this phantom development is applicable to many multi-modality imaging applications.

  8. Do you believe in phantoms?

    CERN Multimedia

    Rosaria Marraffino

    2015-01-01

    “Phantoms” are tools that simulate a therapy’s response by mimicking the conditions of the human body. They are required in hadron therapy in order to optimise and verify the therapy before performing it on the patient. The better the phantom, the more accurate the treatment plan and the more effective the therapy. In the framework of the EU-funded project ENTERVISION*, a team of CERN researchers has designed an innovative piece of equipment able to evaluate radiobiology-related parameters in a very accurate way.   The ENTERVISION phantom being tested at HIT. A key challenge in hadron therapy – i.e. the medical use of hadrons to treat cancer – is to evaluate the biological effect of the delivered radiation. This can be achieved by using accurate dosimetry techniques to study the biological response in terms of the dose deposited and other physical parameters of the beam, such as the Linear Energy Transfer (LET). The job of the “phan...

  9. The phantom limb in dreams.

    Science.gov (United States)

    Brugger, Peter

    2008-12-01

    Mulder and colleagues [Mulder, T., Hochstenbach, J., Dijkstra, P. U., Geertzen, J. H. B. (2008). Born to adapt, but not in your dreams. Consciousness and Cognition, 17, 1266-1271.] report that a majority of amputees continue to experience a normally-limbed body during their night dreams. They interprete this observation as a failure of the body schema to adapt to the new body shape. The present note does not question this interpretation, but points to the already existing literature on the phenomenology of the phantom limb in dreams. A summary of published investigations is complemented by a note on phantom phenomena in the dreams of paraplegic patients and persons born without a limb. Integration of the available data allows the recommendation for prospective studies to consider dream content in more detail. For instance, "adaptation" to the loss of a limb can also manifest itself by seeing oneself surrounded by amputees. Such projective types of anosognosia ("transitivism") in nocturnal dreams should also be experimentally induced in normally-limbed individuals, and some relevant techniques are mentioned.

  10. Physical phantom of craniospinal hydrodynamics.

    Science.gov (United States)

    Bouzerar, R; Czosnyka, M; Czosnyka, Z; Balédent, Olivier

    2012-01-01

    Inside the craniospinal system, blood, and cerebrospinal fluid (CSF) interactions occurring through volume exchanges are still not well understood. We built a physical model of this global hydrodynamic system. The main objective was to study, in controlled conditions, CSF-blood interactions to better understand the phenomenon underlying pathogenesis of hydrocephalus. A structure representing the cranium is connected to the spinal channel. The cranium is divided into compartments mimicking anatomical regions such as ventricles or aqueduct cerebri. Resistive and compliant characteristics of blood and CSF compartments can be assessed or measured using pressure and flow sensors incorporated in the model. An arterial blood flow input is generated by a programmable pump. Flows and pressures inside the system are simultaneously recorded. Preliminary results show that the model can mimic venous and CSF flows in response to arterial pressure input. Pulse waveforms and volume flows were measured and confirmed that they partially replicated the data previously obtained with phase-contrast magnetic resonance imaging. The phantom shows that CSF oscillations directly result from arteriovenous flow, and intracranial pressure measurements show that the model obeys an exponential relationship between pressure and intracranial volume expansion. The phantom will be useful to investigate the hydrodynamic hypotheses underlying development of hydrocephalus.

  11. Successful peripheral neuromodulation for phantom limb pain.

    Science.gov (United States)

    Cornish, Philip; Wall, Cindy

    2015-04-01

    For decades, the heterogeneity of the amputee population and the complex interaction of biopsychosocial factors have confounded researchers' attempts to develop an effective treatment for phantom limb pain. Therefore, it remains difficult to treat, and affected patients often experience decreased quality of life, increased psychological distress, and poorer health outcomes. In the case study, we report a novel strategy for the peripheral placement of neuromodulation leads for the treatment of phantom limb pain in a patient who subsequently described complete and consistent pain relief independent of significant variations in psychosocial stress. Wiley Periodicals, Inc.

  12. Static phantom wormholes of finite size

    Science.gov (United States)

    Cataldo, Mauricio; Orellana, Fabian

    2017-09-01

    In this paper we derive new static phantom traversable wormholes by assuming a shape function with a quadratic dependence on the radial coordinate r . We mainly focus our study on wormholes sustained by exotic matter with positive energy density (as seen by any static observer) and a variable equation of state pr/ρ wormhole spacetimes extending to infinity, we show that a quadratic shape function allows us to construct static spacetimes of finite size, composed of a phantom wormhole connected to an anisotropic spherically symmetric distribution of dark energy. The wormhole part of the full spacetime does not fulfill the dominant energy condition, while the dark energy part does.

  13. Surgical accuracy under virtual reality-enhanced ultrasound guidance: an in vitro epicardial dynamic study.

    Science.gov (United States)

    Linte, Cristian A; Wiles, Andrew D; Moore, John; Wedlake, Chris; Peters, Terry M

    2008-01-01

    In the context of our ongoing objective to reduce morbidity associated with cardiac interventions, minimizing invasiveness has inevitably led to more limited visual access to the target tissues. To ameliorate these challenges, we provide the surgeons with a complex visualization environment that integrates interventional ultrasound imaging augmented with pre-operative anatomical models and virtual surgical instruments within a virtual reality environment. In this paper we present an in vitro study on a cardiac phantom aimed at assessing the feasibility and targeting accuracy of our surgical system in comparison to traditional ultrasound imaging for intra-operative surgical guidance. The 'therapy delivery' was modeled in the context of a blinded procedure, mimicking a closed-chest intervention. Four users navigated a tracked pointer to a target, under guidance provide by either US imaging or virtual reality-enhanced ultrasound. A 2.8 mm RMS targeting error was achieved using our novel surgical system, which is adequate from both a clinical and engineering perspective, under the inherent procedure requirements and limitations of the system.

  14. Anisotropic Bianchi-I universe with phantom field and cosmological ...

    Indian Academy of Sciences (India)

    We study an anisotropic Bianchi-I universe in the presence of a phantom field and a cosmological constant. Cosmological solutions are obtained when the kinetic energy of the phantom field is of the order of anisotropy and dominates over the potential energy of the field. The anisotropy of the universe decreases and the ...

  15. Effects of different tube potentials and iodine concentrations on image enhancement, contrast-to-noise ratio and noise in micro-CT images: a phantom study.

    Science.gov (United States)

    Abdul Razak, Hairil Rashmizal; Shaffiq Said Rahmat, Said Mohd; Md Saad, Wan Mazlina

    2013-10-01

    The study aimed to investigate the effects of different tube potentials and concentrations of iodinated contrast media (CM) on the image enhancement, contrast-to-noise ratio (CNR) and noise in micro-computed tomography (µCT) images. A phantom containing of five polyethylene tube was filled with 2 mL of deionized water and iodinated CM (Omnipaque 300 mgI/mL) at four different concentrations: 5, 10, 15, and 20 mol/L, respectively. The phantom was scanned with a µCT machine (SkyScan 1176) using various tube potentials: 40, 50, 60, 70, 80, and 90 kVp, a fixed tube current; 100 µA, and filtration of 0.2 mm aluminum (Al). The percentage difference of image enhancement, CNR and noise of all images, acquired at different kVps and concentrations, were calculated. The image enhancement, CNR and noise curves with respect to tube potential and concentration were plotted and analysed. The highest image enhancement was found at the lowest tube potential of 40 kVp. At this kVp setting, the percentage difference of image enhancement [Hounsfield Unit (HU) of 20 mol/L iodine concentration over HU of deionized water] was 43%. By increasing the tube potential, it resulted with the reduction of HU, where only 17.5% different were noticed for 90 kVp. Across all iodine concentrations (5-20 M), CNR peaked at 80 kVp and then these values showed a slight decreasing pattern, which might be due insufficient tube current compensation. The percentage difference of image noise obtained at 40 and 90 kVp was 72.4%. Lower tube potential setting results in higher image enhancement (HU) in conjunction with increasing concentration of iodinated CM. Overall, the tube potential increment will substantially improve CNR and reduce image noise.

  16. Effect of reduced radiation exposure and iterative reconstruction on detection of low-contrast low-attenuation lesions in an anthropomorphic liver phantom: an 18-reader study.

    Science.gov (United States)

    Goenka, Ajit H; Herts, Brian R; Obuchowski, Nancy A; Primak, Andrew N; Dong, Frank; Karim, Wadih; Baker, Mark E

    2014-07-01

    To measure the effect of reduced radiation exposure on low-contrast low-attenuation liver lesion detection in an anthropomorphic abdominal phantom by using filtered back projection (FBP) and sinogram-affirmed iterative reconstruction. Eighteen radiologists blinded to phantom and study design interpreted randomized image data sets that contained 36 spherical simulated liver lesions of three sizes and three attenuation differences (5-mm diameter: 12, 18, and 24 HU less than the 90-HU background attenuation of the simulated liver insert; 10- and 15-mm diameter: 6, 12, and 18 HU less than the 90-HU background attenuation) scanned with four discrete exposure settings and reconstructed by using FBP and sinogram-affirmed iterative reconstruction. Response assessment included region-level lesion presence or absence on a five-point diagnostic confidence scale. Statistical evaluation included multireader multicase receiver operating characteristic curve analysis, with nonparametric methods and noninferiority analysis at a margin of -0.10. Pooled accuracy at 75% exposure for both FBP and sinogram-affirmed iterative reconstruction was noninferior to 100% exposure (P = .002 and P iterative reconstruction was superior to FBP at 100% exposure (P = .011), and sinogram-affirmed iterative reconstruction at 25% and 50% exposure reduction was noninferior to FBP at 100% exposure (P ≤ .013). Reader confidence was greater with sinogram-affirmed iterative reconstruction than with FBP for 10- and 15-mm lesions (2.94 vs 2.76 and 3.62 vs 3.52, respectively). In this low-contrast low-attenuation liver lesion model, a 25% exposure reduction maintained noninferior diagnostic accuracy. However, detection was inferior with each subsequent exposure reduction, regardless of reconstruction method. Sinogram-affirmed iterative reconstruction and FBP performed equally well at modest exposure reduction (25%-50%). Readers had higher confidence levels with sinogram-affirmed iterative reconstruction for

  17. Application of dual-energy CT to suppression of metal artefact caused by pedicle screw fixation in radiotherapy: a feasibility study using original phantom

    Science.gov (United States)

    Wang, Tianyuan; Ishihara, Takeaki; Kono, Atsushi; Yoshida, Naoki; Akasaka, Hiroaki; Mukumoto, Naritoshi; Yada, Ryuichi; Ejima, Yasuo; Yoshida, Kenji; Miyawaki, Daisuke; Kakutani, Kenichiro; Nishida, Kotaro; Negi, Noriyuki; Minami, Toshiaki; Aoyama, Yuuichi; Takahashi, Satoru; Sasaki, Ryohei

    2017-08-01

    The objective of the present study was the determination of the potential dosimetric benefits of using metal-artefact-suppressed dual-energy computed tomography (DECT) images for cases involving pedicle screw implants in spinal sites. A heterogeneous spinal phantom was designed for the investigation of the dosimetric effect of the pedicle-screw-related artefacts. The dosimetric comparisons were first performed using a conventional two-directional opposed (AP-PA) plan, and then a volumetric modulated arc therapy (VMAT) plan, which are both used for the treatment of spinal metastases in our institution. The results of Acuros® XB dose-to-medium (Dm) and dose-to-water (Dw) calculations using different imaging options were compared with experimental measurements including the chamber and film dosimetries in the spinal phantom. A dual-energy composition image with a weight factor of  -0.2 and a dual-energy monochromatic image (DEMI) with an energy level of 180 keV were found to have superior abilities for artefact suppression. The Dm calculations revealed greater dosimetric effects of the pedicle screw-related artefacts compared to the Dw calculations. The results of conventional single-energy computed tomography showed that, although the pedicle screws were made from low-Z titanium alloy, the metal artefacts still have dosimetric effects, namely, an average (maximum) Dm error of 4.4% (5.6%) inside the spinal cord for a complex VMAT treatment plan. Our findings indicate that metal-artefact suppression using the proposed DECT (DEMI) approach is promising for improving the dosimetric accuracy near the implants and inside the spinal cord (average (maximum) Dm error of 1.1% (2.0%)).

  18. High signal intensity on T1-weighted MR image related to vacuum cleft in the intervertebral disk; clinical and phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Tae Gyun; Kim, Yong Sun; Chang, Yongmin; Lee, Sang Kwon; Kim, Young Hwan; Ryeom, Hyun Kyu; Lee, Jong Min; Lee, Chang Hyon; Kim, Tae Hun [Kyungpook National Univ. College of Medicine , Taegu (Korea, Republic of); Suh, Kyung Jin [Suh and Joo MRI Center, Taegu (Korea, Republic of)

    2000-12-01

    To determine the possible mechanism by which an area of high signal intensity appears on T1-weighted MR images adjacent to a vacuum cleft in intervertebral disks. We analyzed a total of 14 disks in nine patients in whom a vacuum cleft with T1-signal hyperintensity was observed. Lesions were present from T11-12 to L5-S1 using a 1.5-T whole-body imager, sagittal spine-echo T1-weighted and gradient-echo images (flip angle, 20 .deg. and 60 .deg.) were obtained. In order to identify the vacuum cleft, using plain radiographs in all patients and CT scans in two were also obtained. A 3% agar-gel block containing empty slits to form a magnetic susceptibility difference, a phantom was designed. The air spaces were 1.6mm in thickness, 25mm in width, and 20 to 25mm in depth with 1.6-mm spacing. In all patients, vacuum clefts were confirmed by plain radiographs and CT scans. At the level containing air, T1-weighted images (both spin-echo and gradient-echo) showed a signal void resulting from the intervertebral disk vacuum cleft. A hyperintense band adjacent to the vacuum cleft was, however, observed. A gradient-echo image with a 60 .deg. flip angle showed a brighter signal intensity than one with a 20 .deg. angle. Our phantom study gave the same results. The magnetic susceptibility artifact may be responsible for the T1-signal hyperintensity observed adjacent to the vacuum cleft in intervertebral disks. In addition, in order to generate signal hyperintensity, the desiccating disk material must contain a certain amount of water molecules.

  19. Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study.

    Science.gov (United States)

    Kim, Min Tae; Park, Jung-Hoon; Shin, Ji Hoon; Kim, Namkug; Kim, Sunghyun Daniel; Tsauo, Jiaywei; Kim, Kun Young; Kim, Guk Bae; Song, Ho-Young

    2017-02-01

    To determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom. A comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom. Compared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively). Use of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

  20. Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Tae; Park, Jung-Hoon; Shin, Ji Hoon, E-mail: jhshin@amc.seoul.kr; Kim, Namkug, E-mail: namkugkim@gmail.com [University of Ulsan College of Medicine, Departments of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of); Kim, Sunghyun Daniel [Seoul National University College of Medicine (Korea, Republic of); Tsauo, Jiaywei; Kim, Kun Young [University of Ulsan College of Medicine, Departments of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of); Kim, Guk Bae [University of Ulsan College of Medicine, Biomedical Engineering Research Center, Asan Medical Center (Korea, Republic of); Song, Ho-Young [University of Ulsan College of Medicine, Departments of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2017-02-15

    PurposeTo determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom.Materials and MethodsA comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom.ResultsCompared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively).ConclusionsUse of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

  1. Fast kVp-switching dual energy contrast-enhanced thorax and cardiac CT: A phantom study on the accuracy of iodine concentration and effective atomic number measurement.

    Science.gov (United States)

    Papadakis, Antonios E; Damilakis, John

    2017-09-01

    To assess the effect of vessel diameter and exposure parameters on the estimation accuracy of concentration and effective atomic number (Z eff ) of iodine (I) in contrast-enhanced thorax and cardiac dual-energy CT using a modern fast kVp-switching CT scanner. A standard semi-anthropomorphic cardiac CT phantom devised to simulate the human chest at three different body habitus i.e., medium-sized, large-sized, and obese, was scanned using a fast kVp-switching Revolution-GSI GE CT scanner. Five cylindrical, 10 mm diameter, vials were filled with solutions prepared by diluting I contrast at five concentrations (2.5, 5, 10, 15, and 20 mg I/ml). To simulate small vessels, pipette tips with a diameter ranging from 5 mm to 0.5 mm were employed. The vials and pipette tips were accommodated within the semi-anthropomorphic phantom. CT acquisitions were performed in the fast kVp-switching dual-energy mode at six different CTDI w values. Acquisitions were also performed at 80, 100, 120, and 140 kVp. Images were acquired at 64 × 0.625 mm beam collimation and reconstructed at 2.5 mm using all available reconstruction filter kernels. Virtual monochromatic spectral (VMS) images, iodine concentration (I Meas ), and Z eff maps were reconstructed. Hounsfield unit as a function of energy (HU keV ) in VMS and single-kVp (HU kVp ), I Meas and Z eff were measured at each CTDI w . The effect of vessel diameter on I Meas and Z eff was investigated. Measured HU keV and Z eff were compared to theoretically estimated values and I Meas were compared to nominal (I Nom ) values. In 10 mm diameter vessels, HU keV values were accurate to 18% for the medium-sized, 22% for the large-sized and 39% for the obese phantoms. I Meas was underestimated by up to 10% for the medium-sized, 26% for the large-sized and 33% for the obese phantom. I Meas error decreased with increasing CTDI w from ±0.799 mg/ml at 8.61 mGy to ±0.082 mg/ml at 32.01 mGy. The percentage difference between measured and theoretically

  2. Generation of voxelized breast phantoms from surgical mastectomy specimens.

    Science.gov (United States)

    O'Connor, J Michael; Das, Mini; Dider, Clay S; Mahd, Mufeed; Glick, Stephen J

    2013-04-01

    In the research and development of dedicated tomographic breast imaging systems, digital breast object models, also known as digital phantoms, are useful tools. While various digital breast phantoms do exist, the purpose of this study was to develop a realistic high-resolution model suitable for simulating three-dimensional (3D) breast imaging modalities. The primary goal was to design a model capable of producing simulations with realistic breast tissue structure. The methodology for generating an ensemble of digital breast phantoms was based on imaging surgical mastectomy specimens using a benchtop, cone-beam computed tomography system. This approach allowed low-noise, high-resolution projection views of the mastectomy specimens at each angular position. Reconstructions of these projection sets were processed using correction techniques and diffusion filtering prior to segmentation into breast tissue types in order to generate phantoms. Eight compressed digital phantoms and 20 uncompressed phantoms from which an additional 96 pseudocompressed digital phantoms with voxel dimensions of 0.2 mm(3) were generated. Two distinct tissue classification models were used in forming breast phantoms. The binary model classified each tissue voxel as either adipose or fibroglandular. A multivalue scaled model classified each tissue voxel as percentage of adipose tissue (range 1%-99%). Power spectral analysis was performed to compare simulated reconstructions using the breast phantoms to the original breast specimen reconstruction, and fits were observed to be similar. The digital breast phantoms developed herein provide a high-resolution anthropomorphic model of the 3D uncompressed and compressed breast that are suitable for use in evaluating and optimizing tomographic breast imaging modalities. The authors believe that other research groups might find the phantoms useful, and therefore they offer to make them available for wider use.

  3. In vitro permeation studies of diclofenac diethylamine from newly ...

    African Journals Online (AJOL)

    The study was designed to investigate the feasibility of developing a transdermal drug dosage form of diclofenac diethylamine (DDA). The in vitro release and diffusion characteristics of DDA from two dermatological oleogel bases were studied using full thickness skin from the abdominal hairless surface of rabbit, as the ...

  4. A Randomized Controlled Study to Evaluate The Efficacy of Farabloc for Chronic Phantom Limb Pain Among Veteran Amputees

    Science.gov (United States)

    Hsiao, An-Fu; York, Robyn; Hsiao, Ian; Hansen, Ed; Hays, Ron D.; Ives, John; Coulter, Ian D.

    2013-01-01

    OBJECTIVE Assess the efficacy of Farabloc for treating chronic phantom limb pain (PLP). DESIGN Randomized, double-blind, placebo controlled trial. SETTING VA Long Beach Healthcare System Outpatient Amputee Clinic. PARTICIPANTS We randomized 57 subjects into two groups: true Farabloc (n=30) and sham Farabloc (n=27). Inclusion criteria included age ≥ 18 years, upper or lower extremity amputation with healed stump, and ≥ 3 episodes of PLP during previous 6 weeks. INTERVENTIONS Subjects received two true or sham Farabloc limb covers to be worn over the prosthesis and stumps 24 hours/day for 12 weeks. MAIN OUTCOME MEASURES Primary outcome measure was the numerical pain rating scale of PLP level (0-10). Secondary outcomes included overall pain level (0-10), PLP frequency/week, and the Veterans RAND 12-Item Health Survey (VR-12). We collected data at baseline, 6-week, and 12-week follow-up visits. RESULTS Demographic and clinical characteristics were not significantly different between groups. The true Farabloc group reported non-significant reductions in PLP from 5.9 (SD = 1.9) at baseline to 3.9 (SD = 1.7) at the 12-week follow-up. The sham Farabloc group also had non-significant reducations in PLP from 6.5 (SD = 1.8) to 4.2 (SD = 2.3). PLP did not differ significantly between the two groups at 6 weeks (mean difference, +0.8 [95% confidence intervals (CI), −1.4 to 3]) or at 12 weeks (mean difference, +0.2 [ 95% CI −1.9 to 2.3]). Similarly, overall pain level, PLP episodes/week, and VR-12 physical and mental health component scores did not differ between two groups at 6 weeks and 12 weeks. CONCLUSIONS True Farabloc did not significantly decrease PLP levels or frequency of PLP episodes/week, overall bodily pain levels, or VR-12 physical and mental health component scores compared with sham Farabloc in our Veteran amputee sample. PMID:22464089

  5. Heterogeneous Breast Phantom Development for Microwave Imaging Using Regression Models

    Directory of Open Access Journals (Sweden)

    Camerin Hahn

    2012-01-01

    Full Text Available As new algorithms for microwave imaging emerge, it is important to have standard accurate benchmarking tests. Currently, most researchers use homogeneous phantoms for testing new algorithms. These simple structures lack the heterogeneity of the dielectric properties of human tissue and are inadequate for testing these algorithms for medical imaging. To adequately test breast microwave imaging algorithms, the phantom has to resemble different breast tissues physically and in terms of dielectric properties. We propose a systematic approach in designing phantoms that not only have dielectric properties close to breast tissues but also can be easily shaped to realistic physical models. The approach is based on regression model to match phantom's dielectric properties with the breast tissue dielectric properties found in Lazebnik et al. (2007. However, the methodology proposed here can be used to create phantoms for any tissue type as long as ex vivo, in vitro, or in vivo tissue dielectric properties are measured and available. Therefore, using this method, accurate benchmarking phantoms for testing emerging microwave imaging algorithms can be developed.

  6. Heterogeneous Breast Phantom Development for Microwave Imaging Using Regression Models

    Science.gov (United States)

    Hahn, Camerin; Noghanian, Sima

    2012-01-01

    As new algorithms for microwave imaging emerge, it is important to have standard accurate benchmarking tests. Currently, most researchers use homogeneous phantoms for testing new algorithms. These simple structures lack the heterogeneity of the dielectric properties of human tissue and are inadequate for testing these algorithms for medical imaging. To adequately test breast microwave imaging algorithms, the phantom has to resemble different breast tissues physically and in terms of dielectric properties. We propose a systematic approach in designing phantoms that not only have dielectric properties close to breast tissues but also can be easily shaped to realistic physical models. The approach is based on regression model to match phantom's dielectric properties with the breast tissue dielectric properties found in Lazebnik et al. (2007). However, the methodology proposed here can be used to create phantoms for any tissue type as long as ex vivo, in vitro, or in vivo tissue dielectric properties are measured and available. Therefore, using this method, accurate benchmarking phantoms for testing emerging microwave imaging algorithms can be developed. PMID:22550473

  7. Multimodal phantom of liver tissue.

    Directory of Open Access Journals (Sweden)

    Magdalena K Chmarra

    Full Text Available Medical imaging plays an important role in patients' care and is continuously being used in managing health and disease. To obtain the maximum benefit from this rapidly developing technology, further research is needed. Ideally, this research should be done in a patient-safe and environment-friendly manner; for example, on phantoms. The goal of this work was to develop a protocol and manufacture a multimodal liver phantom that is suitable for ultrasound, computed tomography, and magnetic resonance imaging modalities. The proposed phantom consists of three types of mimicked soft tissues: liver parenchyma, tumors, and portal veins, that are made of six ingredients: candle gel, sephadex®, agarose, glycerol, distilled water, and silicone string. The entire procedure is advantageous, since preparation of the phantom is simple, rather cost-effective, and reasonably quick - it takes around 2 days. Besides, most of the phantom's parts can be reused to manufacture a new phantom. Comparison of ultrasound images of real patient's liver and the developed phantom shows that the phantom's liver tissue and its structures are well simulated.

  8. Supernumerary phantom limb after stroke

    Science.gov (United States)

    Bakheit, A; Roundhill, S

    2005-01-01

    The perception of a phantom limb is commonly reported after amputations. However, only a few cases have been described after a stroke. This article presents a patient who reported a supernumerary phantom limb (pseudopolymelia) after spontaneous intracerebral haemorrhage and discusses the possible underlying mechanisms for this rare phenomenon. PMID:15749787

  9. Effect of Attenuation Correction on Regional Quantification Between PET/MR and PET/CT: A Multicenter Study Using a 3-Dimensional Brain Phantom

    National Research Council Canada - National Science Library

    Teuho, Jarmo; Johansson, Jarkko; Linden, Jani; Hansen, Adam Espe; Holm, Søren; Keller, Sune H; Delso, Gaspar; Veit-Haibach, Patrick; Magota, Keiichi; Saunavaara, Virva; Tolvanen, Tuula; Teräs, Mika; Iida, Hidehiro

    2016-01-01

    .... We performed an evaluation among 4 institutions, 3 PET/MR systems, and 4 PET/CT systems using an anthropomorphic brain phantom, hypothesizing that the spatial bias would be minimized with CT-based...

  10. Phantom breast sensations are frequent after mastectomy

    DEFF Research Database (Denmark)

    Hansen, Dorthe Marie Helbo; Kehlet, Henrik; Gärtner, Rune

    2011-01-01

    Phantom breast sensation (PBS) following mastectomy has been recognized for many years. PBS is a feeling that the removed breast is still there. The reported prevalence and risk factors have not been established in large well-defined patient series. The purpose of this study was to examine...... the prevalence of PBS following mastectomy and associated risk factors....

  11. Phantom breast sensations are frequent after mastectomy

    DEFF Research Database (Denmark)

    Hansen, Dorthe Marie Helbo; Kehlet, Henrik; Gærtner, Rune

    2011-01-01

    Phantom breast sensation (PBS) following mastectomy has been recognized for many years. PBS is a feeling that the removed breast is still there. The reported prevalence and risk factors have not been established in large well-defined patient series. The purpose of this study was to examine...

  12. Validation of phantom-based harmonization for patient harmonization.

    Science.gov (United States)

    Panetta, Joseph V; Daube-Witherspoon, Margaret E; Karp, Joel S

    2017-07-01

    To improve the precision of multicenter clinical trials, several efforts are underway to determine scanner-specific parameters for harmonization using standardized phantom measurements. The goal of this study was to test the correspondence between quantification in phantom and patient images and validate the use of phantoms for harmonization of patient images. The National Electrical Manufacturers' Association image quality phantom with hot spheres was scanned on two time-of-flight PET scanners. Whole-body [18 F]-fluorodeoxyglucose (FDG)-PET scans were acquired of subjects on the same systems. List-mode events from spheres (diam.: 10-28 mm) measured in air on each scanner were embedded into the phantom and subject list-mode data from each scanner to create lesions with known uptake with respect to the local background in the phantom and each subject's liver and lung regions, as a proxy to characterize true lesion quantification. Images were analyzed using the contrast recovery coefficient (CRC) typically used in phantom studies and serving as a surrogate for the standardized uptake value used clinically. Postreconstruction filtering (resolution recovery and Gaussian smoothing) was applied to determine if the effect on the phantom images translates equivalently to subject images. Three postfiltering strategies were selected to harmonize the CRCmean or CRCmax values between the two scanners based on the phantom measurements and then applied to the subject images. Both the average CRCmean and CRCmax values for lesions embedded in the lung and liver in four subjects (BMI range 25-38) agreed to within 5% with the CRC values for lesions embedded in the phantom for all lesion sizes. In addition, the relative changes in CRCmean and CRCmax resulting from the application of the postfilters on the subject and phantom images were consistent within measurement uncertainty. Further, the root mean squared percent difference (RMSpd ) between CRC values on the two scanners

  13. Building and assessing anatomically relevant phantoms for neonatal transcranial ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Memoli, G; Sadhoo, N; Gelat, P; Shaw, A [Acoustics and Ionising Radiation Division, National Physical Laboratory, Teddington (United Kingdom); Gatto, M; Harris, R A, E-mail: gianluca.memoli@npl.co.uk [Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Loughborough (United Kingdom)

    2011-02-01

    This study describes the design and construction of a clinically relevant phantom to survey the temperature increase caused by ultrasound equipment, as currently used in neonatal head-scanning in the UK. The phantom is an ellipsoid of bone-mimic material, filled with brain-mimic; a circular hole in the external surface mimicks the fontanel, through which most clinically relevant scans are made. Finite-element simulations were used to identify possible hot spots and decide the most effective thermocouple positions within the phantom to investigate temperature rise during a typical scan. Novel materials were purposively designed to simulate key acoustic and thermal properties. Three Dimensional Printing (3DP) was employed for the fabrication of the skull phantom, and a specific strategy was successfully pursued to embed a thermocouple within the 3DP skull phantom during the manufacturing process. An in-process Non-Destructive Analysis (NDA) was used to assess the correct position of the deposited thermocouple inside the fabricated skull phantom. The temperature increase in the phantom for a typical trans-fontanellar scan is also presented here. The current phantom will be used in a hospital survey in the UK and, in its final design, will allow for a more reliable evaluation of ultrasound heating than is currently possible.

  14. Evaluation of DQA for tomography using 3D volumetric phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Uk [Dept. of Radiation Oncology, Catholic University of Incheon St. Mary' s Hospital, Incheon (Korea, Republic of); Kim, Jeong Koo [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of)

    2016-12-15

    The study investigates the necessity of 3 dimensional dose distribution evaluation instead of point dose and 2 dimensional dose distribution evaluation. Treatment plans were generated on the RANDO phantom to measure the precise dose distribution of the treatment site 0.5, 1, 1.5, 2, 2.5, 3 cm with the prescribed dose; 1,200 cGy, 5 fractions. Gamma analysis (3%/3 mm, 2%/2 mm) of dose distribution was evaluated with gafchromic EBT2 film and ArcCHECK phantom. The average error of absolute dose was measured at 0.76±0.59% and 1.37±0.76% in cheese phantom and ArcCHECK phantom respectively. The average passing ratio for 3%/3 mm were 97.72±0.02% and 99.26±0.01% in gafchromic EBT2 film and ArcCHECK phantom respectively. The average passing ratio for 2%/2 mm were 94.21±0.02% and 93.02±0.01% in gafchromic EBT2 film and ArcCHECK phantom respectively. There was a more accurate dose distribution of 3D volume phantom than cheese phantom in patients DQA using tomotherapy. Therefor it should be evaluated simultaneously 3 dimensional dose evaluation on target and peripheral area in rotational radiotherapy such as tomotherapy.

  15. Use of model-based iterative reconstruction (MBIR) in reduced-dose CT for routine follow-up of patients with malignant lymphoma: dose savings, image quality and phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Herin, Edouard; Chiaradia, Melanie; Cavet, Madeleine; Deux, Jean-Francois; Rahmouni, Alain [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); Gardavaud, Francois; Beaussart, Pauline [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Richard, Philippe [GE Healthcare France, Buc (France); Haioun, Corinne [Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); AP-HP, Hopitaux Universitaires Henri Mondor, Hemopathies Lymphoides, Creteil (France); Itti, Emmanuel [Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); AP-HP, Hopitaux Universitaires Henri Mondor, Medecine Nucleaire, Creteil (France); Luciani, Alain [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); INSERM Unite U 955, Creteil (France); AP-HP, Groupe Henri Mondor Albert Chenevier, Imagerie Medicale, CHU Henri Mondor, Creteil Cedex (France)

    2015-08-15

    To evaluate both in vivo and in phantom studies, dose reduction, and image quality of body CT reconstructed with model-based iterative reconstruction (MBIR), performed during patient follow-ups for lymphoma. This study included 40 patients (mean age 49 years) with lymphoma. All underwent reduced-dose CT during follow-up, reconstructed using MBIR or 50 % advanced statistical iterative reconstruction (ASIR). All had previously undergone a standard dose CT with filtered back projection (FBP) reconstruction. The volume CT dose index (CTDIvol), the density measures in liver, spleen, fat, air, and muscle, and the image quality (noise and signal to noise ratio, SNR) (ANOVA) observed using standard or reduced-dose CT were compared both in patients and a phantom study (Catphan 600) (Kruskal Wallis). The CTDIvol was decreased on reduced-dose body CT (4.06 mGy vs. 15.64 mGy p < 0.0001). SNR was higher in reduced-dose CT reconstructed with MBIR than in 50 % ASIR or than standard dose CT with FBP (patients, p ≤ 0.01; phantoms, p = 0.003). Low contrast detectability and spatial resolution in phantoms were not altered on MBIR-reconstructed CT (p ≥ 0.11). Reduced-dose CT with MBIR reconstruction can decrease radiation dose delivered to patients with lymphoma, while keeping an image quality similar to that obtained on standard-dose CT. (orig.)

  16. Characterization and in vitro studies on anticancer activity of ...

    African Journals Online (AJOL)

    Characterization of exopolymer shows the presence of brominated compound responsible for cytotoxicity on lung cancer cell line (A549) on XTT assay. An in vitro study of bacterial exopolymer shows the presence of cytotoxic effects on cell lines. Further, active compound in exopolymer responsible for cytotoxicity has to be ...

  17. Characterization and in vitro studies on anticancer activity of ...

    African Journals Online (AJOL)

    SAM

    2014-05-21

    May 21, 2014 ... S13. Characterization of exopolymer shows the presence of brominated compound responsible for cytotoxicity on lung cancer cell line (A549) on XTT assay. An in vitro study of bacterial exopolymer shows the presence of cytotoxic effects on cell lines. Further, active compound in exopolymer responsible for ...

  18. In vitro placental model optimization for nanoparticle transport studies

    DEFF Research Database (Denmark)

    Cartwright, Laura; Poulsen, Marie Sønnegaard; Nielsen, Hanne Mørck

    2012-01-01

    on polycarbonate membranes (3.0 μm pore size) was four times higher for the 50 nm particles compared with the 100 nm particles. CONCLUSION: The BeWo cell line has been optimized and shown to be a valid in vitro model for studying the transplacental transport of nanoparticles. Fluorescent polystyrene nanoparticle...

  19. In vitro metabolism and pharmacokinetic studies on methylone

    DEFF Research Database (Denmark)

    Pedersen, Anders Just; Petersen, Trine Hedebrink; Linnet, Kristian

    2013-01-01

    Abuse of the stimulant designer drug methylone (methylenedioxymethcathinone) has been documented in most parts of the world. As with many of the new designer drugs that continuously appear in the illicit drug market, little is known about the pharmacokinetics of methylone. Using in vitro studies...

  20. In Vitro Drug Release Studies of Metronidazole Topical ...

    African Journals Online (AJOL)

    Three different topical formulations namely gel, cream and ointment, each containing 1% w/w metronidazole, were prepared and in vitro permeation studies carried out. The permeation of metronidazole from each of the topical formulation was determined using dialyzing cellulose membrane in a dissolution tester. Glycerin ...

  1. Use of Calcitonin in Recalcitrant Phantom Limb Pain Complicated by Heterotopic Ossification

    Directory of Open Access Journals (Sweden)

    Ricardo Viana

    2015-01-01

    Full Text Available A common complication following amputation is phantom sensation, which may include experiencing pain in the phantom limb. This study details the management of phantom limb pain in a 72-year-old man, in whom comorbid heterotopic ossification was present. In addition, the authors provide a review of the literature regarding phantom limb pain management, and summarize the current understanding of heterotopic ossification and its possible link to peripheral nerve injury.

  2. Emdogain in carcinogenesis: a systematic review of in vitro studies.

    Science.gov (United States)

    Laaksonen, Matti; Sorsa, Timo; Salo, Tuula

    2010-03-01

    Emdogain is a commercial product of unknown composition and is clinically used to induce periodontal regeneration. This study aims to review current knowledge of the in vitro effects of Emdogain on oral tissues and, in particular, factors related to carcinoma. A systematic approach was used to review studies from the Embase and Pubmed databases; a total of 76 studies were included. These comprised in vitro studies of the cytokines in, or regulated by, Emdogain and assays designed to study the effects of EMD on human cells in oral tissues or malignant cells. Several studies have shown that EMD regulates the proliferation, migration, adhesion, gene expression, and cytokine production of (pre-)osteoblasts, periodontal fibroblasts, and gingival fibroblasts. However, the effects of EMD on malignant oral cells are not well understood. EMD seems to have broad regulatory effects on malignant cells and on several carcinoma-related factors. Evidence suggests that patients with premalignant or malignant mucosal lesions should not be treated with EMD.

  3. A study on in vitro propagation of Castanopsis argentea

    Directory of Open Access Journals (Sweden)

    MUHAMMAD IMAM SURYA

    2017-03-01

    Full Text Available Abstract. Surya MI, Kurnita NI, Setyaningsih L, Ismaini L, Muttaqin Z. 2016. A study on in vitro propagation of Castanopsis argentea. Pros Sem Nas Masy Biodiv Indon 2: 10-15. Saninten (Castanopsis argentea is a keystone species that has highly potential as a food material. Mostly, the fruits of C. argentea are eaten by animals. It made us difficults to get the natural regeneration. In vitro propagation is an effort to produce considerable amounts of C. argentea. However, the information about in vitro propagation of C. argentea is still very limited. This study was aimed to determine the initiation methods to propagate C. argentea by in vitro propagation. Two methods of sterilization were used to sterilize the explant of seed and buds. Moreover, the explant was planted on modified MS and WPM. The results show that percentage of survival, number of buds and time of germination were found on seed explants sterilized by first method. The number of callus were found on bud explants sterilized by second method. Furthermore, planting media were not affected to the germination of seed explants, but affected to growth of bud explants.

  4. A simple phantom study of the effects of dose reduction (by kVp increment) below current dose levels on CR chest image quality

    Energy Technology Data Exchange (ETDEWEB)

    Egbe, N.O., E-mail: nneoyiegbe@yahoo.co [Department of Biomedical Physics and Bioengineering, University of Aberdeen, Forresterhill (United Kingdom); Heaton, B.; Sharp, P.F. [Department of Biomedical Physics and Bioengineering, University of Aberdeen, Forresterhill (United Kingdom)

    2010-11-15

    Purpose: To assess the applicability of a simple commercial chest phantom incorporating a quasi anthropomorphic insert, in image quality and dose optimisation studies in computed radiography (CR). Methods: Lung and mediastinal lesions simulated with gelatine were positioned on the chest phantom and exposures made at the current chest radiography dose, set as D{sub ref} in the study. Further exposures were made at doses below D{sub ref} to study the effect of reducing patient dose below current dose levels, on the clarity and detectability of lung lesions in computed radiography. Lesion detectability and clarity was assessed by four observers using a commercial image viewing software without image manipulation, and a local image viewing software that allowed image contrast enhancement. The possibility of extending dose reduction below current dose levels (D{sub ref}) was assessed for both unmanipulated and manipulated images, from comparison of doses that produced statistically significant differences in image quality from D{sub ref}. Results: Results show that as the dose was decreased below D{sub ref}, both the clarity and detectability of lesions in the lung images worsened when there was no facility to manipulate the image. The onset of a significant difference in image clarity in the lung area occurred at 0.06 mGy while significant detectability changes were observed at 0.04 mGy. Similar changes in image quality were observed with the use of image manipulation. However, dose reduction produced statistically significant differences (p < 0.05) in both image clarity and detectability at 0.10 mGy. Image clarity and detectability in the mediastinal area showed no statistical difference at all doses (p > 0.05) with and without image manipulation. Conclusion: The clarity and detectability of lesion images as a function of patient doses in computed radiography may be dependent on whether or not contrast enhancement techniques are employed. There is also evidence to

  5. Computerized scheme for evaluating mammographic phantom images.

    Science.gov (United States)

    Asahara, Masaki; Kodera, Yoshie

    2012-03-01

    The authors developed a computer algorithm to automatically evaluate images of the American College of Radiology (ACR) mammography accreditation phantom. The developed algorithm consist of the edge detection of wax insert, nonuniformity correction of background, and correction for magnification and also calculate the cross-correlation coefficient by image matching technique. The algorithm additionally evaluates target shape for fibers, target contrast for speck groups, and target circularity for masses. To obtain an ideal template image without noise and spatial resolution loss, the wax insert containing the embedded test pattern was extracted from the phantom and radiographed. Two template images and ten test phantom images were prepared for this study. The results of evaluation using the algorithm outputs were compared with the averaged results of observer studies by six skilled observers. In comparing the results from the algorithm outputs with the results of observers, the authors found that the computer outputs were well correlated with the evaluations by observers, and they indicate the quality of the phantom image. The correlation coefficients between results of observer studies and two outputs of computer algorithm, i.e., the cross-correlation coefficient by template matching and indices of target shape for fibers, were 0.89 (95% confidence interval, 0.82-0.93; hereinafter the same) and 0.85 (0.76-0.91). The correlation coefficients between observer's results and two outputs: the cross-correlation coefficient and indices of target contrast for speck groups, were 0.83 (0.79-0.86) and 0.85 (0.81-0.88) and between observer's results and two outputs: the cross-correlation coefficient and indices of target circularity for masses, were 0.90 (0.84-0.94) and 0.87 (0.77-0.92). Image evaluation using the ACR phantom is indispensable in quality control of a mammography system. The proposed algorithm is useful for quality control and image evaluation of mammography

  6. The impact of image reconstruction settings on 18F-FDG PET radiomic features. Multi-scanner phantom and patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Shiri, Isaac; Abdollahi, Hamid [Iran University of Medical Sciences, Department of Medical Physics, School of Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Johns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, MD (United States); Ghaffarian, Pardis [Shahid Beheshti University of Medical Sciences, Chronic Respiratory Diseases Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Tehran (Iran, Islamic Republic of); Shahid Beheshti University of Medical Sciences, PET/CT and Cyclotron Center, Masih Daneshvari Hospital, Tehran (Iran, Islamic Republic of); Geramifar, Parham [Tehran University of Medical Sciences, Research Center for Nuclear Medicine, Shariati Hospital, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad [Iran University of Medical Sciences, Department of Medical Physics, School of Medicine, Tehran (Iran, Islamic Republic of); Iran University of Medical Sciences, Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Tehran (Iran, Islamic Republic of)

    2017-11-15

    The purpose of this study was to investigate the robustness of different PET/CT image radiomic features over a wide range of different reconstruction settings. Phantom and patient studies were conducted, including two PET/CT scanners. Different reconstruction algorithms and parameters including number of sub-iterations, number of subsets, full width at half maximum (FWHM) of Gaussian filter, scan time per bed position and matrix size were studied. Lesions were delineated and one hundred radiomic features were extracted. All radiomics features were categorized based on coefficient of variation (COV). Forty seven percent features showed COV ≤ 5% and 10% of which showed COV > 20%. All geometry based, 44% and 41% of intensity based and texture based features were found as robust respectively. In regard to matrix size, 56% and 6% of all features were found non-robust (COV > 20%) and robust (COV ≤ 5%) respectively. Variability and robustness of PET/CT image radiomics in advanced reconstruction settings is feature-dependent, and different settings have different effects on different features. Radiomic features with low COV can be considered as good candidates for reproducible tumour quantification in multi-center studies. (orig.)

  7. Integration of a real-time tumor monitoring system into gated proton spot-scanning beam therapy: An initial phantom study using patient tumor trajectory data

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Taeko; Miyamoto, Naoki; Takao, Seishin; Nihongi, Hideaki; Toramatsu, Chie; Sutherland, Kenneth; Suzuki, Ryusuke; Ishikawa, Masayori; Maeda, Kenichiro [Department of Medical Physics, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido, 060-8638 (Japan); Shimizu, Shinichi; Kinoshita, Rumiko; Umegaki, Kikuo; Shirato, Hiroki [Department of Radiation Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido, 060-8648 (Japan); Fujii, Yusuke; Umezawa, Masumi [Hitachi, Ltd., Hitachi Research Laboratory, 7-2-1 Omika-cho, Hitachi-shi, Ibaraki 319-1221 (Japan)

    2013-07-15

    Purpose: In spot-scanning proton therapy, the interplay effect between tumor motion and beam delivery leads to deterioration of the dose distribution. To mitigate the impact of tumor motion, gating in combination with repainting is one of the most promising methods that have been proposed. This study focused on a synchrotron-based spot-scanning proton therapy system integrated with real-time tumor monitoring. The authors investigated the effectiveness of gating in terms of both the delivered dose distribution and irradiation time by conducting simulations with patients' motion data. The clinically acceptable range of adjustable irradiation control parameters was explored. Also, the relation between the dose error and the characteristics of tumor motion was investigated.Methods: A simulation study was performed using a water phantom. A gated proton beam was irradiated to a clinical target volume (CTV) of 5 Multiplication-Sign 5 Multiplication-Sign 5 cm{sup 3}, in synchronization with lung cancer patients' tumor trajectory data. With varying parameters of gate width, spot spacing, and delivered dose per spot at one time, both dose uniformity and irradiation time were calculated for 397 tumor trajectory data from 78 patients. In addition, the authors placed an energy absorber upstream of the phantom and varied the thickness to examine the effect of changing the size of the Bragg peak and the number of required energy layers. The parameters with which 95% of the tumor trajectory data fulfill our defined criteria were accepted. Next, correlation coefficients were calculated between the maximum dose error and the tumor motion characteristics that were extracted from the tumor trajectory data.Results: With the assumed CTV, the largest percentage of the data fulfilled the criteria when the gate width was {+-}2 mm. Larger spot spacing was preferred because it increased the number of paintings. With a prescribed dose of 2 Gy, it was difficult to fulfill the

  8. IQ SPECT allows a significant reduction in administered dose and acquisition time for myocardial perfusion imaging: evidence from a phantom study.

    Science.gov (United States)

    Caobelli, Federico; Kaiser, Stefano Ren; Thackeray, James T; Bengel, Frank M; Chieregato, Matteo; Soffientini, Alberto; Pizzocaro, Claudio; Savelli, Giordano; Galelli, Marco; Guerra, Ugo Paolo

    2014-12-01

    We recently demonstrated in a clinical trial the ability of a new protocol, IQ SPECT, to acquire myocardial perfusion imaging (MPI) studies in a quarter of the time (12 s/view) of the standard protocol, with preserved diagnostic accuracy. We now aim to establish the lower limit of radioactivity that can be administered to patients and the minimum acquisition time in SPECT MPI using an IQ SPECT protocol, while preserving diagnostic accuracy. An anthropomorphic cardiac phantom was used to acquire clinical rest scans with a simulated in vivo distribution of (99m)Tc-tetrofosmin at full dose (740 MBq) and at doses equal to 50%, 25%, and 18%. For each dose, 2 sets of images were acquired, with and without a transmural defect (TD). Variable acquisition times were also used for each dose. We analyzed raw data and reconstructed images, including no correction and correction for attenuation (AC), for scatter (SC), or for both (ACSC). Images were evaluated qualitatively and quantitatively in order to assess left ventricle (LV) wall thickness (full width at half maximum of the medial sections), TD, and cavity contrast in the LV wall. Data were compared across different acquisition times within the same dose and across doses with the same acquisition time. Images were visually scored as very-good quality except those acquired with 4 s/view or less at 100% dose and 6 s/view or less with 50%, 25%, or 18% dose, due to false-positive defects. LV wall thickness was not significantly different among all acquisitions. Cavity contrast remained unchanged within the same dose for all images and tended to be higher in AC and ACSC images. TD contrast remained unchanged within the same dose for all images. In SC and no-correction images, contrast was constant for all doses. AC images had significantly higher TD contrast values, and ACSC images showed a drop in TD contrast for a 50% dose. IQ SPECT effectively preserved both image quality and quantitative measurements with reduced acquisition

  9. Optimizing radiation dose levels in prospectively electrocardiogram-triggered coronary computed tomography angiography using iterative reconstruction techniques: a phantom and patient study.

    Directory of Open Access Journals (Sweden)

    Yang Hou

    Full Text Available AIM: To investigate the potential of reducing the radiation dose in prospectively electrocardiogram-triggered coronary computed tomography angiography (CCTA while maintaining diagnostic image quality using an iterative reconstruction technique (IRT. METHODS AND MATERIALS: Prospectively-gated CCTA were first performed on a phantom using 256-slice multi-detector CT scanner at 120 kVp, with the tube output gradually reduced from 210 mAs (Group A to 125, 105, 84, and 63 mAs (Group B-E. All scans were reconstructed using filtered back projection (FBP algorithm and five IRT levels (L2-6, image quality (IQ assessment was performed. Based on the IQ assessment, Group D(120 kVp, 84 mAs reconstructed with L5 was found to provide IQ comparable to that of Group A with FBP. In the patient study, 21 patients underwent CCTA using 120 kV, 210 mAs with FBP reconstruction (Group 1 followed by 36 patients scanned with 120 kV, 84 mAs with IRT L5 (Group 2. Subjective and objective IQ and effective radiation dose were compared between two groups. RESULTS: In the phantom scans, there were no significant differences in image noise, contrast-to-noise ratio (CNR and modulation transfer function (MTF curves between Group A and the 84 mAs, 63 mAs groups (Groups D and E. Group D (120 kV, 84 mAs and L5 provided an optimum balance, producing equivalent image quality to Group A, at the lowest possible radiation dose. In the patient study, there were no significant difference in image noise, signal-to-noise ratio (SNR and CNR between Group 1 and Group 2 (p=0.71, 0.31, 0.5, respectively. The effective radiation dose in Group 2 was 1.21 ± 0.14 mSv compared to 3.20 ± 0.58 mSv (Group 1, reflecting dose savings of 62.5% (p<0.05. CONCLUSION: iterative reconstruction technique used in prospectively ECG-triggered 256-slice coronary CTA can provide radiation dose reductions of up to 62.5% with acceptable image quality.

  10. NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging.

    Science.gov (United States)

    Ziegler, Susanne; Jakoby, Bjoern W; Braun, Harald; Paulus, Daniel H; Quick, Harald H

    2015-12-01

    In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2-2007 is challenging because of incomplete MR-based attenuation correction (AC) for phantom imaging. In this study, a strategy for CT-based AC of the NEMA image quality (IQ) phantom is assessed. The method is systematically evaluated in NEMA IQ phantom measurements on an integrated PET/MR system. NEMA IQ measurements were performed on the integrated 3.0 Tesla PET/MR hybrid system (Biograph mMR, Siemens Healthcare). AC of the NEMA IQ phantom was realized by an MR-based and by a CT-based method. The suggested CT-based AC uses a template μ-map of the NEMA IQ phantom and a phantom holder for exact repositioning of the phantom on the systems patient table. The PET image quality parameters contrast recovery, background variability, and signal-to-noise ratio (SNR) were determined and compared for both phantom AC methods. Reconstruction parameters of an iterative 3D OP-OSEM reconstruction were optimized for highest lesion SNR in NEMA IQ phantom imaging. Using a CT-based NEMA IQ phantom μ-map on the PET/MR system is straightforward and allowed performing accurate NEMA IQ measurements on the hybrid system. MR-based AC was determined to be insufficient for PET quantification in the tested NEMA IQ phantom because only photon attenuation caused by the MR-visible phantom filling but not the phantom housing is considered. Using the suggested CT-based AC, the highest SNR in this phantom experiment for small lesions (PET/MR hybrid system. The superiority of CT-based AC for this phantom is demonstrated by comparison to measurements using MR-based AC. Furthermore, optimized PET image reconstruction parameters are provided for the highest lesion SNR in NEMA IQ phantom measurements.

  11. The importance of a correct positioning of the heart using IQ-SPECT system with multifocal collimators in myocardial perfusion imaging: a phantom study.

    Science.gov (United States)

    Caobelli, Federico; Ren Kaiser, Stefano; Thackeray, James Thomas; Bengel, Frank Michael; Chieregato, Matteo; Soffientini, Alberto; Pizzocaro, Claudio; Savelli, Giordano; Guerra, Ugo Paolo; Galelli, Marco; Zoccarato, Orazio

    2015-02-01

    We have recently validated a quarter-time protocol in Myocardial Perfusion Imaging named IQ-SPECT, whose basic principle is to implement a multifocal collimator; However, in clinical practice, it may sometimes be difficult to center the heart in the region of highest magnification of the multifocal collimators (the so-called sweet spot). We therefore aimed to evaluate whether a heart mispositioning may affect results in MPI. We simulated a rest study with an anthropomorphic phantom with an in vivo distribution of 400 MBq [(99m)Tc]tetrofosmin, with and without a transmural defect (TD). For each set of images, we performed 5 acquisitions, one with a correct centering and with other 4 degrees of mispositioning. Raw data and reconstructed images were evaluated qualitatively and quantitatively, including no corrections, correction for attenuation, for scatter or for both. We assessed polar plot uniformity, LV wall thickness, and TD and cavity contrast. Images obtained either with a correct heart centering or with mild misposition showed no differences, both qualitatively and quantitatively. Those obtained with major mispositioning differed in uniformity and TD contrast depending on correction parameters. This is the first study investigating how a heart mispositioning can affect diagnostic accuracy with IQ-SPECT system. Mild-to-moderate mispositioning (≤2.5 cm) is unlikely to significantly affect results.

  12. Dispersion characteristics of the flexural wave assessed using low frequency (50-150kHz) point-contact transducers: A feasibility study on bone-mimicking phantoms.

    Science.gov (United States)

    Kassou, Koussila; Remram, Youcef; Laugier, Pascal; Minonzio, Jean-Gabriel

    2017-11-01

    Guided waves-based techniques are currently under development for quantitative cortical bone assessment. However, the signal interpretation is challenging due to multiple mode overlapping. To overcome this limitation, dry point-contact transducers have been used at low frequencies for a selective excitation of the zeroth order anti-symmetric Lamb A0 mode, a mode whose dispersion characteristics can be used to infer the thickness of the waveguide. In this paper, our purpose was to extend the technique by combining a dry point-contact transducers approach to the SVD-enhanced 2-D Fourier transform in order to measure the dispersion characteristics of the flexural mode. The robustness of our approach is assessed on bone-mimicking phantoms covered or not with soft tissue-mimicking layer. Experiments were also performed on a bovine bone. Dispersion characteristics of measured modes were extracted using a SVD-based signal processing technique. The thickness was obtained by fitting a free plate model to experimental data. The results show that, in all studied cases, the estimated thickness values are in good agreement with the actual thickness values. From the results, we speculate that in vivo cortical thickness assessment by measuring the flexural wave using point-contact transducers is feasible. However, this assumption has to be confirmed by further in vivo studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Study of Tissue Phantoms, Tissues, and Contrast Agent with the Biophotoacoustic Radar and Comparison to Ultrasound Imaging for Deep Subsurface Imaging

    Science.gov (United States)

    Alwi, R.; Telenkov, S.; Mandelis, A.; Gu, F.

    2012-11-01

    In this study, the imaging capability of our wide-spectrum frequency-domain photoacoustic (FD-PA) imaging alias "photoacoustic radar" methodology for imaging of soft tissues is explored. A practical application of the mathematical correlation processing method with relatively long (1 ms) frequency-modulated optical excitation is demonstrated for reconstruction of the spatial location of the PA sources. Image comparison with ultrasound (US) modality was investigated to see the complementarity between the two techniques. The obtained results with a phased array probe on tissue phantoms and their comparison to US images demonstrated that the FD-PA technique has strong potential for deep subsurface imaging with excellent contrast and high signal-to-noise ratio. FD-PA images of blood vessels in a human wrist and an in vivo subcutaneous tumor in a rat model are presented. As in other imaging modalities, the employment of contrast agents is desirable to improve the capability of medical diagnostics. Therefore, this study also evaluated and characterized the use of Food and Drug Administration (FDA)-approved superparamagnetic iron oxide nanoparticles (SPION) as PA contrast agents.

  14. A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-D diode array

    Science.gov (United States)

    Curley, Casey Michael

    Monte Carlo (MC) and Pencil Beam (PB) calculations are compared to their measured planar dose distributions using a 2-D diode array for lung Stereotactic Body Radiation Therapy (SBRT). The planar dose distributions were studied for two different phantom types: an in-house heterogeneous phantom and a homogeneous phantom. The motivation is to mimic the human anatomy during a lung SBRT treatment and incorporate heterogeneities into the pre-treatment Quality Assurance process, where measured and calculated planar dose distributions are compared before the radiation treatment. Individual and combined field dosimetry has been performed for both fixed gantry angle (anterior to posterior) and planned gantry angle delivery. A gamma analysis has been performed for all beam arrangements. The measurements were obtained using the 2-D diode array MapCHECK 2(TM). MC and PB calculations were performed using the BrainLAB iPlan RTRTM Dose software. The results suggest that with the heterogeneous phantom as a quality assurance device, the MC calculations result in closer agreements to the measured values, when using the planned gantry angle delivery method for composite beams. For the homogeneous phantom, the results suggest that the preferred delivery method is at the fixed anterior to posterior gantry angle. Furthermore, the MC and PB calculations do not show significant differences for dose difference and distance to agreement criteria 3%/3mm. However, PB calculations are in better agreement with the measured values for more stringent gamma criteria when considering individual beam whereas MC agreements are closer for composite beam measurements.

  15. Individual differences in response to phantom limb movement therapy.

    Science.gov (United States)

    McAvinue, Laura P; Robertson, Ian H

    2011-01-01

    Phantom limb pain (PLP) is a distressing condition experienced by many amputees. The purpose of this study was to investigate whether motor imagery could be used to treat PLP. Four single case studies were conducted. The participants kept a pain diary in which they recorded the intensity of their PLP during a baseline period, general motor imagery training, phantom limb movement therapy and a follow-up period. Qualitative and quantitative (i.e. interrupted time series) analyses were employed to determine whether phantom limb movement therapy had a significant effect on PLP intensity. Phantom limb movement therapy significantly reduced intensity of PLP in one participant. One participant gained occasional relief by doing phantom limb movement therapy exercises but did not experience an overall reduction in PLP intensity. The third participant did not experience any relief and the fourth participant reported experiencing the re-emergence of an old pain. The results display individual differences in response to phantom limb movement therapy. Individual differences are discussed in the context of motor imagery ability and the phantom limb phenomenon as a multi-dimensional disorder.

  16. Evaluation of a Robotic Assistance-System For Percutaneous Computed Tomography-Guided (CT-Guided) Facet Joint Injection: A Phantom Study.

    Science.gov (United States)

    Beyer, Lukas Philipp; Michalik, Katharina; Niessen, Christoph; Platz Batista da Silva, Natascha; Wiesinger, Isabell; Stroszczynski, Christian; Wiggermann, Philipp

    2016-09-20

    BACKGROUND The aim of this study was to compare robotic assisted and freehand facet joint puncture on a phantom model in regards to time requirements and puncture accuracy. MATERIAL AND METHODS Forty facet joints were punctured, 20 using a robotic guidance system and 20 using a freehand procedure. Side and height of the facet joints were randomized and identical for both groups. Procedural accuracy, defined as axial and sagittal deviation, as well as the number of corrections were assessed. Procedure times for each step were documented and time requirements for pre-positioning, reconstruction, planning, and total intervention were calculated. RESULTS Total procedure time for robotic guidance was 259±111 seconds versus 119±77 seconds for freehand procedure (p=1.0). Procedural accuracy for robotic guidance was significantly higher with 0 corrections versus 1.3 corrections for freehand procedure (p=0.02). Needle deviation in the robotics arm was 0.35±1.1 mm in the axial and 2.15±1.2 mm in the sagittal reconstruction. CONCLUSIONS Robotic assisted puncture of the facet joint allowed accurate positioning of the needle with a lower number of needle readjustments. Higher procedural accuracy was marginally offset by a slightly longer intervention time.

  17. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Di Leo, Giovanni; Zanardo, Moreno; Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Spadavecchia, Chiara [Universita degli Studi di Milano, Dipartimento di Fisica, Milano (Italy); Veronese, Ivan [Universita degli Studi di Milano, Dipartimento di Fisica, Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Cantone, Marie Claire [Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Milano (Italy); Sardanelli, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Universita degli Studi di Milano, Department of Biomedical Science for Health, San Donato Milanese (Italy)

    2017-07-15

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. (orig.)

  18. Advances and Challenges in Studying Hepatitis B Virus In Vitro

    Directory of Open Access Journals (Sweden)

    Dvora Witt-Kehati

    2016-01-01

    Full Text Available Hepatitis B virus (HBV is a small DNA virus that infects the liver. Current anti-HBV drugs efficiently suppress viral replication but do not eradicate the virus due to the persistence of its episomal DNA. Efforts to develop reliable in vitro systems to model HBV infection, an imperative tool for studying HBV biology and its interactions with the host, have been hampered by major limitations at the level of the virus, the host and infection readouts. This review summarizes major milestones in the development of in vitro systems to study HBV. Recent advances in our understanding of HBV biology, such as the discovery of the bile-acid pump sodium-taurocholate cotransporting polypeptide (NTCP as a receptor for HBV, enabled the establishment of NTCP expressing hepatoma cell lines permissive for HBV infection. Furthermore, advanced tissue engineering techniques facilitate now the establishment of HBV infection systems based on primary human hepatocytes that maintain their phenotype and permissiveness for infection over time. The ability to differentiate inducible pluripotent stem cells into hepatocyte-like cells opens the door for studying HBV in a more isogenic background, as well. Thus, the recent advances in in vitro models for HBV infection holds promise for a better understanding of virus-host interactions and for future development of more definitive anti-viral drugs.

  19. Development of skeleton model for use in polygonal-mesh-type ICRP reference phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thang Tat; Yeom, Yeon Soo; Han, Min Cheol; Wang, Zhao Jun; Kim, Han Sung; Kim, Chan Hyeong [Dept.of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of)

    2015-04-15

    In order to overcome the limitations, we are currently developing the polygonal-mesh versions of the ICRP reference phantoms by converting the ICRP reference voxel phantoms to polygonal-mesh format. As a part of the ICRP reference phantom conversion project, the present study completed the conversion of skeleton, which is a very complex framework of the body, while addressing some critical problems of the skeleton of the ICRP reference voxel phantoms. The converted skeleton models were also evaluated by comparing dose values of RBM and endosteum with those of the ICRP reference voxel phantoms. As a part of the ICRP reference phantom conversion project, the present study successfully completed skeleton conversion of the ICRP reference adult male and female phantoms to polygonal-mesh format. A comprehensive study of dosimetric effects by the skeleton conversion will be performed in the future.

  20. Phantom limb pain: a case of maladaptive CNS plasticity?

    Science.gov (United States)

    Flor, Herta; Nikolajsen, Lone; Staehelin Jensen, Troels

    2006-11-01

    Phantom pain refers to pain in a body part that has been amputated or deafferented. It has often been viewed as a type of mental disorder or has been assumed to stem from pathological alterations in the region of the amputation stump. In the past decade, evidence has accumulated that phantom pain might be a phenomenon of the CNS that is related to plastic changes at several levels of the neuraxis and especially the cortex. Here, we discuss the evidence for putative pathophysiological mechanisms with an emphasis on central, and in particular cortical, changes. We cite both animal and human studies and derive suggestions for innovative interventions aimed at alleviating phantom pain.

  1. Studies of In Vitro Embryo Culture of Guppy (Poecilia reticulata).

    Science.gov (United States)

    Liu, LiLi; Lee, Ki-Young

    2014-09-01

    Different with other fishes, the guppies (Poecilia reticulata) is ovoviviparity, which retain their fertilized eggs within the follicle throughout gestation. The synchronously growing diplotene oocytes store nutrients in droplets and yolk, before their maturation and fertilization. The lecithotrophic strategy of development entails the provisioning of embryos with resources from the maternal yolk deposit rather than from a placenta, it allows the extracorporeal culture of guppy embryo. Studies on their early development of live bearers like the guppy including lineage tracing and genetic manipulations, have been limited. Therefore, to optimize conditions of embryo in vitro culture, explanted embryos from pregnant females were incubated in embryo medium (L-15 medium, supplemented with 5, 10, 15, 20% fetal bovine serum, respectively). We investigated whether the contents of FBS in vitro culture medium impact the development of embryos, and whether they would hatch in vitro. Our study found that in 5% of FBS of the medium, although embryos developed significantly slower in vitro than in the ovary, it was impossible to exactly quantify the developmental delay in culture, due to the obvious spread in developmental stage within each batch of eggs, and embryos can only be maintained until the early-eyed. And although in culture with 20% FBS the embryos can sustain rapid development of early stage, but cannot be cultured for the entire period of their embryonic development and ultimately died. In the medium with 10% and 15% FBS, the embryos seems well developed, even some can continue to grow after follicle ruptures until it can be fed. We also observed that embryonic in these two culture conditions were significantly different in development speed, in 15% it is faster than 10%. But 10% FBS appears to be more optimizing condition than 15% one on development process of embryos and survival rate to larvae stage.

  2. Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study.

    Science.gov (United States)

    Jeong, Ii-Do; Kim, Woong-Chul; Park, Jinyoung; Kim, Chong-Myeong; Kim, Ji-Hwan

    2017-08-01

    This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (α=.05). The RMS value of lithium disilicate crown was 29.2 (4.1) µm and 17.6 (5.5) µm on the outer and inner surfaces, respectively, whereas these values were 18.6 (2.0) µm and 20.6 (5.1) µm for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

  3. A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lequerica, Juan L [Cardiac Research Laboratory, Instituto de Biomedicina, Spanish Council for Scientific Research (CSIC), Valencia (Spain); Berjano, Enrique J [Institute for Research and Innovation on Bioengineering, Valencia Polytechnic University, Valencia (Spain); Herrero, Maria [Cardiac Research Laboratory, Instituto de Biomedicina, Spanish Council for Scientific Research (CSIC), Valencia (Spain); Melecio, Lemuel [Cardiac Research Laboratory, Instituto de Biomedicina, Spanish Council for Scientific Research (CSIC), Valencia (Spain); Hornero, Fernando [Department of Cardiac Surgery, Consorcio Hospital General Universitario, Valencia (Spain)

    2008-02-21

    A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a significant effect on the temperature measured at 2 mm from the esophageal lumen (it has a less effect on the temperature measured on the balloon surface) and (3) the pre-cooling period has a significant effect on the temperature measured on the balloon surface (the effect on the temperature measured 2 mm away is small). The results were in good agreement with those obtained in a previous clinical study. The study suggests that the cooling balloon gives thermal protection to the esophagus when a minimum pre-cooling period of 2 min is programmed at a coolant temperature of 5 deg. C or less. (note)

  4. In vitro antioxidant studies in leaves of Annona species.

    Science.gov (United States)

    Baskar, R; Rajeswari, V; Kumar, T Sathish

    2007-05-01

    Antioxidant potential of leaves of three different species of Annona was studied by using different in vitro models eg., 1,1-diphenyl-2-picryl hydrazyl (DPPH), 2,2-azinobis-(3-ethylbenzothizoline-6-sulphonate) (ABTS), nitric oxide, superoxide, hydroxy radical and lipid peroxidation. The ethanolic extract of A. muricata at 500 microg/ml showed maximum scavenging activity (90.05%) of ABTS radical cation followed by the scavenging of hydroxyl radical (85.88%) and nitric oxide (72.60%) at the same concentration. However, the extract showed only moderate lipid peroxidation inhibition activity. In contrast, the extract of A. reticulata showed better activity in quenching DPPH (89.37%) and superoxide radical (80.88%) respectively. A.squamosa extract exhibited least inhibition in all in vitro antioxidant models excepting hydroxyl radical (79.79%). These findings suggest that the extracts of A. muricata possess potent in vitro antioxidant activity as compared to leaves of A. squamosa and A. reticulata suggesting its role as an effective free radical scavenger, augmenting its therapeutic

  5. Computer-assisted solid lung nodule 3D volumetry on CT : influence of scan mode and iterative reconstruction: a CT phantom study

    NARCIS (Netherlands)

    Coenen, Adriaan; Honda, Osamu; van der Jagt, Eric J.; Tomiyama, Noriyuki

    2013-01-01

    To evaluate the effect of high-resolution scan mode and iterative reconstruction on lung nodule 3D volumetry. Solid nodules with various sizes (5, 8, 10 and 12 mm) were placed inside a chest phantom. CT images were obtained with various tube currents, scan modes (conventional mode, high-resolution

  6. Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study

    NARCIS (Netherlands)

    Boomsma, Martijn F.; Warringa, Niek; Edens, Mireille A.; Mueller, Dirk; Ettema, Harmen B.; Verheyen, Cees C. P. M.; Maas, Mario

    2016-01-01

    Purpose: Quantification of the effect of O-MAR on decreasing metal artefacts caused by large head metal on metal total hip arthroplasty (MoM THA) in a dedicated phantom setup of the hip. Background: Pathological reactions of the hip capsule on Computed tomography (CT) can be difficult to diagnose

  7. Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM

    Directory of Open Access Journals (Sweden)

    Långström Bengt

    2005-08-01

    Full Text Available Abstract Background Positron Emission Tomography (PET, Computed Tomography (CT, PET/CT and Single Photon Emission Tomography (SPECT are non-invasive imaging tools used for creating two dimensional (2D cross section images of three dimensional (3D objects. PET and SPECT have the potential of providing functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules, whereas CT visualizes X-ray density in tissues in the body. PET/CT provides fused images representing both functional and anatomical information with better precision in localization than PET alone. Images generated by these types of techniques are generally noisy, thereby impairing the imaging potential and affecting the precision in quantitative values derived from the images. It is crucial to explore and understand the properties of noise in these imaging techniques. Here we used autocorrelation function (ACF specifically to describe noise correlation and its non-isotropic behaviour in experimentally generated images of PET, CT, PET/CT and SPECT. Methods Experiments were performed using phantoms with different shapes. In PET and PET/CT studies, data were acquired in 2D acquisition mode and reconstructed by both analytical filter back projection (FBP and iterative, ordered subsets expectation maximisation (OSEM methods. In the PET/CT studies, different magnitudes of X-ray dose in the transmission were employed by using different mA settings for the X-ray tube. In the CT studies, data were acquired using different slice thickness with and without applied dose reduction function and the images were reconstructed by FBP. SPECT studies were performed in 2D, reconstructed using FBP and OSEM, using post 3D filtering. ACF images were generated from the primary images, and profiles across the ACF images were used to describe the noise correlation in different directions. The variance of noise across the images was visualised as images and with profiles

  8. SU-D-201-05: Phantom Study to Determine Optimal PET Reconstruction Parameters for PET/MR Imaging of Y-90 Microspheres Following Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Maughan, N [Washington University in Saint Louis, Saint Louis, MO (United States); Conti, M [Siemens Healthcare Molecular Imaging, Knoxville, TN (United States); Parikh, P [Washington Univ. School of Medicine, Saint Louis, MO (United States); Faul, D [Siemens Healthcare, New York, NY (United States); Laforest, R [Washington University School of Medicine, Saint Louis, MO (United States)

    2015-06-15

    Purpose: Imaging Y-90 microspheres with PET/MRI following hepatic radioembolization has the potential for predicting treatment outcome and, in turn, improving patient care. The positron decay branching ratio, however, is very small (32 ppm), yielding images with poor statistics even when therapy doses are used. Our purpose is to find PET reconstruction parameters that maximize the PET recovery coefficients and minimize noise. Methods: An initial 7.5 GBq of Y-90 chloride solution was used to fill an ACR phantom for measurements with a PET/MRI scanner (Siemens Biograph mMR). Four hot cylinders and a warm background activity volume of the phantom were filled with a 10:1 ratio. Phantom attenuation maps were derived from scaled CT images of the phantom and included the MR phased array coil. The phantom was imaged at six time points between 7.5–1.0 GBq total activity over a period of eight days. PET images were reconstructed via OP-OSEM with 21 subsets and varying iteration number (1–5), post-reconstruction filter size (5–10 mm), and either absolute or relative scatter correction. Recovery coefficients, SNR, and noise were measured as well as total activity in the phantom. Results: For the 120 different reconstructions, recovery coefficients ranged from 0.1–0.6 and improved with increasing iteration number and reduced post-reconstruction filter size. SNR, however, improved substantially with lower iteration numbers and larger post-reconstruction filters. From the phantom data, we found that performing 2 iterations, 21 subsets, and applying a 5 mm Gaussian post-reconstruction filter provided optimal recovery coefficients at a moderate noise level for a wide range of activity levels. Conclusion: The choice of reconstruction parameters for Y-90 PET images greatly influences both the accuracy of measurements and image quality. We have found reconstruction parameters that provide optimal recovery coefficients with minimized noise. Future work will include the effects

  9. The UF family of reference hybrid phantoms for computational radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choonsik [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institute of Health, Bethesda, MD 20852 (United States); Lodwick, Daniel; Hurtado, Jorge; Pafundi, Deanna [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Williams, Jonathan L [Department of Radiology, University of Florida, Gainesville, FL 32611 (United States); Bolch, Wesley E [Departments of Nuclear and Radiological and Biomedical Engineering, University of Florida, Gainesville, FL 32611 (United States)], E-mail: wbolch@ufl.edu

    2010-01-21

    Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms-those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR(TM). NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros(TM). The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference

  10. SU-G-BRA-15: Dosimetric Evaluation of Dynamic Tumor Tracking Radiation Therapy Using Digital Phantom: A Study On Margin and Desired Accuracy of Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T; Osanai, M; Homma, N [Department of Radiological Imaging and Informatics, Tohoku University Graduate School of Medicine (Japan); Kadoya, N; Nakajima, Y; Jingu, K [Department of Radiation Oncology, Tohoku University Graduate School of Medicine (Japan); Ichiji, K [Department of Therapeutic Radiology, Tohoku University Graduate School of Medicine (Japan); Takeda, K [Department of Therapeutic Radiology, Tohoku University Graduate School of Medicine (Japan); Takai, Y [Department of Radiology and Radiation Oncology, Hirosaki University Graduate School of Medicine (Japan)

    2016-06-15

    Purpose: Dynamic tumor tracking radiation therapy can potentially reduce internal margin without prolongation of irradiation time. However, dynamic tumor tracking technique requires an extra margin (tracking margin, TM) for the uncertainty of tumor localization, prediction, and beam repositioning. The purpose of this study was to evaluate a dosimetric impact caused by TM. Methods: We used 4D XCAT to create 9 digital phantom datasets of different tumor size and motion range: tumor diameter TD=(1, 3, 5) cm and motion range MR=(1, 2, 3) cm. For each dataset, respiratory gating (30%–70% phase) and tumor tracking treatment plans were created using 8-field 3D-CRT by 4D dose calculation implemented in RayStation. The dose constraint was based on RTOG0618. For the tracking plan, TMs of (0, 2.5, 5) mm were considered by surrounding a normal setup margin: SM=5 mm. We calculated V20 of normal lung to evaluate the dosimetric impact for each case, and estimated an equivalent TM that affects the same impact on V20 obtained by the gated plan. Results: The equivalent TMs for (TD=1 cm, MR=2 cm), (TD=1 cm, MR=3 cm), (TD=5 cm, MR=2 cm), and (TD=5 cm, MR=3 cm) were estimated as 1.47 mm, 3.95 mm, 1.04 mm, and 2.13 mm, respectively. The larger the tumor size, the equivalent TM became smaller. On the other hand, the larger the motion range, the equivalent TM was found to be increased. Conclusion: Our results showed the equivalent TM changes depending on tumor size and motion range. The tracking plan with TM less than the equivalent TM achieves a dosimetric impact better than the gated plan in less treatment time. This study was partially supported by JSPS Kakenhi and Varian Medical Systems.

  11. WE-AB-BRA-08: Results of a Multi-Institutional Study for the Evaluation of Deformable Image Registration Algorithms for Structure Delineation Via Computational Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Loi, G; Fusella, M [University Hospital “Maggiore della Carita”, Novara (Italy); Fiandra, C [University of Torino, Turin (Italy); Lanzi, E [G. Mazzini Hospital, Teramo (Italy); Rosica, A [Regina Elena National Cancer Institute, Rome (Italy); Strigari, L [Centro Oncologico Fiorentino, Florence (Italy); Orlandini, L [A.O. Ordine Mauriziano di Torino, Turin (Italy); Gino, E [Istituto Oncologico Veneto IOV, Padova (Italy); Roggio, A [Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS, Meldola (Italy); Marcocci, F [ARNAS Civico - Di Cristina - Benfratelli, Palermo (Italy); Iacovello, G; Miceli, R [Tor Vergata University General Hospital, Rome (Italy)

    2015-06-15

    Purpose: To investigate the accuracy of various algorithms for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on patient images using different commercial systems. This work is part of an Italian multi-institutional study to test on common datasets the accuracy, reproducibility and safety of DIR applications in Adaptive Radiotherapy. Methods: Eleven institutions with three available commercial solutions provided data to assess the agreement of DIR-propagated ROIs with automatically drown ROIs considered as ground-truth for the comparison. The DIR algorithms were tested on real patient data from three different anatomical districts: head and neck, thorax and pelvis. For every dataset two specific Deformation Vector Fields (DVFs) provided by ImSimQA software were applied to the reference data set. Three different commercial software were used in this study: RayStation, Velocity and Mirada. The DIR-mapped ROIs were then compared with the reference ROIs using the Jaccard Conformity Index (JCI). Results: More than 600 DIR-mapped ROIs were analyzed. Putting together all JCI data of all institutions for the first DVF, the mean JCI was 0.87 ± 0.7 (1 SD) while for the second DVF JCI was 0.8 ± 0.13 (1 SD). Several considerations on different structures are available from collected data: the standard deviation among different institutions on specific structure raise as the larger is the applied DVF. The higher value is 10% for bladder. Conclusion: Although the complexity of deformation of human body is very difficult to model, this work illustrates some clinical scenarios with well-known DVFs provided by specific software. CI parameter gives the inter-user variability and may put in evidence the need of improving the working protocol in order to reduce the inter-institution JCI variability.

  12. A study of Rhizophora spp wood phantom for dosimetric purposes using high-energy photon and electron beams.

    Science.gov (United States)

    Banjade, D P; Tajuddin, A A; Shukri, A

    2001-09-01

    Previous scattering and depth-dose investigations involving use of the Malaysian hardwood Rhizophora spp have shown this medium to produce good agreement with measurements made in water. Present study extends the comparison, now including measurements of percentage depth-dose made for photons at 6MV and 5 and 12MeV electron beams. For the 6 MV photon and 5 MeV electron beams, discrepancies between percentage depth-dose for Rhizophora spp and water, at all depths, are found to be within 2.6 and 2.4% respectively. At 12 MeV electron energies, measured percentage depth-doses in Rhizophora spp beyond 3.5cm depth are found to be in significant discord with those for water. The absorbed dose in water measured in Rhizophora spp at d(max) for all three beams produces discrepancies of no more than 1.1% when compared with measurements made in water.

  13. A study of Rhizophora spp wood phantom for dosimetric purposes using high-energy photon and electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Banjade, D.P. E-mail: dpbl4007@stud.usm.my; Tajuddin, A.A.; Shukri, A

    2001-09-01

    Previous scattering and depth-dose investigations involving use of the Malaysian hardwood Rhizophora spp have shown this medium to produce good agreement with measurements made in water. Present study extends the comparison, now including measurements of percentage depth-dose made for photons at 6 MV and 5 and 12 MeV electron beams. For the 6 MV photon and 5 MeV electron beams, discrepancies between percentage depth-dose for Rhizophora spp and water, at all depths, are found to be within 2.6 and 2.4% respectively. At 12 MeV electron energies, measured percentage depth-doses in Rhizophora spp beyond 3.5 cm depth are found to be in significant discord with those for water. The absorbed dose in water measured in Rhizophora spp at d{sub max} for all three beams produces discrepancies of no more than 1.1% when compared with measurements made in water.

  14. Acrylonitrile Butadiene Styrene (ABS) plastic based low cost tissue equivalent phantom for verification dosimetry in IMRT.

    Science.gov (United States)

    Kumar, Rajesh; Sharma, S D; Deshpande, Sudesh; Ghadi, Yogesh; Shaiju, V S; Amols, H I; Mayya, Y S

    2009-12-17

    A novel IMRT phantom was designed and fabricated using Acrylonitrile Butadiene Styrene (ABS) plastic. Physical properties of ABS plastic related to radiation interaction and dosimetry were compared with commonly available phantom materials for dose measurements in radiotherapy. The ABS IMRT phantom has provisions to hold various types of detectors such as ion chambers, radiographic/radiochromic films, TLDs, MOSFETs, and gel dosimeters. The measurements related to pre-treatment dose verification in IMRT of carcinoma prostate were carried out using ABS and Scanditronics-Wellhoffer RW3 IMRT phantoms for five different cases. Point dose data were acquired using ionization chamber and TLD discs while Gafchromic EBT and radiographic EDR2 films were used for generating 2-D dose distributions. Treatment planning system (TPS) calculated and measured doses in ABS plastic and RW3 IMRT phantom were in agreement within +/-2%. The dose values at a point in a given patient acquired using ABS and RW3 phantoms were found comparable within 1%. Fluence maps and dose distributions of these patients generated by TPS and measured in ABS IMRT phantom were also found comparable both numerically and spatially. This study indicates that ABS plastic IMRT phantom is a tissue equivalent phantom and dosimetrically it is similar to solid/plastic water IMRT phantoms. Though this material is demonstrated for IMRT dose verification but it can be used as a tissue equivalent phantom material for other dosimetry purposes in radiotherapy.

  15. Efficacy of robust optimization plan with partial-arc VMAT for photon volumetric-modulated arc therapy: A phantom study.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Nagata, Yasushi

    2017-09-01

    This study investigated position dependence in planning target volume (PTV)-based and robust optimization plans using full-arc and partial-arc volumetric modulated arc therapy (VMAT). The gantry angles at the periphery, intermediate, and center CTV positions were 181°-180° (full-arc VMAT) and 181°-360° (partial-arc VMAT). A PTV-based optimization plan was defined by 5 mm margin expansion of the CTV to a PTV volume, on which the dose constraints were applied. The robust optimization plan consisted of a directly optimized dose to the CTV under a maximum-uncertainties setup of 5 mm. The prescription dose was normalized to the CTV D99% (the minimum relative dose that covers 99% of the volume of the CTV) as an original plan. The isocenter was rigidly shifted at 1 mm intervals in the anterior-posterior (A-P), superior-inferior (S-I), and right-left (R-L) directions from the original position to the maximum-uncertainties setup of 5 mm in the original plan, yielding recalculated dose distributions. It was found that for the intermediate and center positions, the uncertainties in the D99% doses to the CTV for all directions did not significantly differ when comparing the PTV-based and robust optimization plans (P > 0.05). For the periphery position, uncertainties in the D99% doses to the CTV in the R-L direction for the robust optimization plan were found to be lower than those in the PTV-based optimization plan (P optimization plan's efficacy using partial-arc VMAT depends on the periphery CTV position. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  16. Image quality dependency on system configuration and tube voltage in chest tomosynthesis—a visual grading study using an anthropomorphic chest phantom.

    Science.gov (United States)

    Söderman, Christina; Asplund, Sara; Allansdotter Johnsson, Åse; Vikgren, Jenny; Rossi Norrlund, Rauni; Molnar, David; Svalkvist, Angelica; Gunnar Månsson, Lars; Båth, Magnus

    2015-03-01

    To investigate the potential benefit of increasing the dose per projection image in chest tomosynthesis, performed at the current standard dose level, by reducing the angular range covered or the projection image density and to evaluate the influence of the tube voltage on the image quality. An anthropomorphic chest phantom was imaged using nine different projection image configurations and ten different tube voltages with the GE VolumeRAD tomosynthesis system. The resulting image sets were representative of being acquired at the same total effective dose. This was achieved partly by applying a simulated dose reduction to the projection images due to restrictions concerning the tube load settings on the VolumeRAD system. Four observers were included in a visual grading study where the reconstructed tomosynthesis section images were rated according to a set of image quality criteria. Image quality was evaluated relative to the default configuration and default tube voltage on the VolumeRAD system. Overall, the image quality decreased with decreasing projection image density. Regarding angular range covered by the projection images, the image quality increased with decreasing angular range for two of the criteria, whereas for a criterion related to the depth resolution in the section images the reduced angular ranges resulted in inferior image quality as compared to the default configuration. The image quality showed little dependence on the tube voltage. At the standard dose level of the VolumeRAD system, the potential benefits from increasing the dose per projection do not fully compensate for the negative effects resulting from a reduction in the number of projection images. Consequently, the default configuration consisting of 60 projection images acquired over 30° is a good alternative. The tube voltage used in tomosynthesis does not have a large impact on the image quality.

  17. Effect of Attenuation Correction on Regional Quantification Between PET/MR and PET/CT: A Multicenter Study Using a 3-Dimensional Brain Phantom.

    Science.gov (United States)

    Teuho, Jarmo; Johansson, Jarkko; Linden, Jani; Hansen, Adam Espe; Holm, Søren; Keller, Sune H; Delso, Gaspar; Veit-Haibach, Patrick; Magota, Keiichi; Saunavaara, Virva; Tolvanen, Tuula; Teräs, Mika; Iida, Hidehiro

    2016-05-01

    A spatial bias in brain PET/MR exists compared with PET/CT, because of MR-based attenuation correction. We performed an evaluation among 4 institutions, 3 PET/MR systems, and 4 PET/CT systems using an anthropomorphic brain phantom, hypothesizing that the spatial bias would be minimized with CT-based attenuation correction (CTAC). The evaluation protocol was similar to the quantification of changes in neurologic PET studies. Regional analysis was conducted on 8 anatomic volumes of interest (VOIs) in gray matter on count-normalized, resolution-matched, coregistered data. On PET/MR systems, CTAC was applied as the reference method for attenuation correction. With CTAC, visual and quantitative differences between PET/MR and PET/CT systems were minimized. Intersystem variation between institutions was +3.42% to -3.29% in all VOIs for PET/CT and +2.15% to -4.50% in all VOIs for PET/MR. PET/MR systems differed by +2.34% to -2.21%, +2.04% to -2.08%, and -1.77% to -5.37% when compared with a PET/CT system at each institution, and these differences were not significant (P ≥ 0.05). Visual and quantitative differences between PET/MR and PET/CT systems can be minimized by an accurate and standardized method of attenuation correction. If a method similar to CTAC can be implemented for brain PET/MRI, there is no reason why PET/MR should not perform as well as PET/CT. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  18. Enhancement effects of hepatic dynamic MR imaging at 3.0 T and 1.5 T using gadoxetic acid in a phantom study: comparison with gadopentetate dimeglumine.

    Science.gov (United States)

    Morita, Kosuke; Namimoto, Tomohiro; Awai, Kazuo; Komi, Masanori; Hashida, Masahiro; Tsuji, Takashi; Hirai, Toshinori; Yamashita, Yasuyuki

    2011-07-01

    To identify the optimum sequence at gadoxetic acid enhanced hepatic dynamic magnetic resonance imaging in the arterial phase, we studied phantoms that contained gadoxetic acid or gadopentetate dimeglumine diluted in human blood. We obtained magnetic resonance images at 3.0 T and 1.5 T with one vendor (Siemens) using 3D-gradient echo (GRE)-, 2D-fast low angle shot (FLASH)-, and turbo spin echo sequences. Contrast ratio was highest for 3D-GRE; at both 3.0 T and 1.5 T it was superior when the contrast agent was gadoxetic acid. With both gadoxetic acid and gadopentetate dimeglumine, contrast ratio peaked at around 5- and 2 mmol/L on 3D-GRE- and 2D-FLASH images, respectively. Compared with gadopentetate dimeglumine, at 3.0 T, the peak contrast ratio of gadoxetic acid was 14.1% better on 3D-GRE images and 14.0% better on 2D-FLASH images; at 1.5 T it was 16.4% better on 3D-GRE- and 5.7% better on 2D-FLASH images. With respect to the magnetic field strength, at 3.0 T the peak contrast ratio of gadoxetic acid was 6.0% better than at 1.5 T on 3D-GRE images and 49.5% better on 2D-FLASH images; it was 8.5% better on 3D-GRE- and 44.6% better on 2D-FLASH images than when the contrast agent was gadopentetate dimeglumine. Thus, gadoxetic acid yielded better enhancement on 3D-GRE images acquired at 3.0 T than at 1.5 T and enhancement was better than that obtained with gadopentetate dimeglumine at the same concentration. Copyright © 2011 Wiley-Liss, Inc.

  19. Power Doppler signal calibration between ultrasound machines by use of a capillary-flow phantom for pannus vascularity in rheumatoid finger joints: a basic study.

    Science.gov (United States)

    Sakano, Ryosuke; Kamishima, Tamotsu; Nishida, Mutsumi; Horie, Tatsunori

    2015-01-01

    Ultrasound allows the detection and grading of inflammation in rheumatology. Despite these advantages of ultrasound in the management of rheumatoid patients, it is well known that there are significant machine-to-machine disagreements regarding signal quantification. In this study, we tried to calibrate the power Doppler (PD) signal of two models of ultrasound machines by using a capillary-flow phantom. After flow velocity analysis in the perfusion cartridge at various injection rates (0.1-0.5 ml/s), we measured the signal count in the perfusion cartridge at various injection rates and pulse repetition frequencies (PRFs) by using PD, perfusing an ultrasound micro-bubble contrast agent diluted with normal saline simulating human blood. By use of the data from two models of ultrasound machines, Aplio 500 (Toshiba) and Avius (Hitachi Aloka), the quantitative PD (QPD) index [the summation of the colored pixels in a 1 cm × 1 cm rectangular region of interest (ROI)] was calculated via Image J (internet free software). We found a positive correlation between the injection rate and the flow velocity. In Aplio 500 and Avius, we found negative correlations between the PRF and the QPD index when the flow velocity was constant, and a positive correlation between flow velocity and the QPD index at constant PRF. The equation for the relationship of the PRF between Aplio 500 and Avius was: y = 0.023x + 0.36 [y = PRF of Avius (kHz), x = PRF of Aplio 500 (kHz)]. Our results suggested that the signal calibration of various models of ultrasound machines is possible by adjustment of the PRF setting.

  20. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study.

    Science.gov (United States)

    Di Leo, Giovanni; Spadavecchia, Chiara; Zanardo, Moreno; Secchi, Francesco; Veronese, Ivan; Cantone, Marie Claire; Sardanelli, Francesco

    2017-07-01

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. • CT-AEC system is not impaired in patients with endoaortic prostheses/heart valves. • Negligible differences may be observed only at 120 kVp. • Disabling the AEC system in these patients is not recommended.

  1. Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study.

    Science.gov (United States)

    Bala, Chandra; Shi, Jeffrey; Meades, Kerrie

    2015-06-01

    To transect intraocular lenses (IOLs) using a femtosecond laser in cadaveric human eyes. To determine the optimal in vitro settings, to detect and characterize gasses or particles generated during this process. A femtosecond laser was used to transect hydrophobic and hydrophilic acrylic lenses. The settings required to enable easy separation of the lens fragment were determined. The gasses and particles generated were analysed using gas chromatography mass spectrometer (GC-MS) and total organic carbon analyzer (TOC), respectively. In vitro the IOL fragments easily separated at the lowest commercially available energy setting of 1 μJ, 8-μm spot, and 2-μm line separation. No particles were detected in the 0.5- to 900-μm range. No significant gasses or other organic breakdown by products were detected at this setting. At much higher energy levels 12 μJ (4 × 6 μm spot and line separation) significant pyrolytic products were detected, which could be harmful to the eye. In cadaveric explanted IOL capsule complex the laser pulses could be applied through the capsule to the IOL and successfully fragment the IOL. IOL transection is feasible with femtosecond lasers. Further in vivo animal studies are required to confirm safety. In clinical practice there are a number of large intraocular lenses that can be difficult to explant. This in-vitro study examines the possibility of transecting the lasers quickly using femtosecond lasers. If in-vivo studies are successful, then this innovation could help ophthalmic surgeons in IOL explantation.

  2. Initial implementation of the conversion from the energy-subtracted CT number to electron density in tissue inhomogeneity corrections: an anthropomorphic phantom study of radiotherapy treatment planning.

    Science.gov (United States)

    Tsukihara, Masayoshi; Noto, Yoshiyuki; Sasamoto, Ryuta; Hayakawa, Takahide; Saito, Masatoshi

    2015-03-01

    To achieve accurate tissue inhomogeneity corrections in radiotherapy treatment planning, the authors had previously proposed a novel conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU-ρ(e) conversion), which provides a single linear relationship between ΔHU and ρ(e) over a wide range of ρ(e). The purpose of this study is to present an initial implementation of the ΔHU-ρ(e) conversion method for a treatment planning system (TPS). In this paper, two example radiotherapy plans are used to evaluate the reliability of dose calculations in the ΔHU-ρ(e) conversion method. CT images were acquired using a clinical dual-source CT (DSCT) scanner operated in the dual-energy mode with two tube potential pairs and an additional tin (Sn) filter for the high-kV tube (80-140 kV/Sn and 100-140 kV/Sn). Single-energy CT using the same DSCT scanner was also performed at 120 kV to compare the ΔHU-ρ(e) conversion method with a conventional conversion from a CT number to ρ(e) (Hounsfield units, HU-ρ(e) conversion). Lookup tables for ρ(e) calibration were obtained from the CT image acquisitions for tissue substitutes in an electron density phantom (EDP). To investigate the beam-hardening effect on dosimetric uncertainties, two EDPs with different sizes (a body EDP and a head EDP) were used for the ρ(e) calibration. Each acquired lookup table was applied to two radiotherapy plans designed using the XiO TPS with the superposition algorithm for an anthropomorphic phantom. The first radiotherapy plan was for an oral cavity tumor and the second was for a lung tumor. In both treatment plans, the performance of the ΔHU-ρ(e) conversion was superior to that of the conventional HU-ρ(e) conversion in terms of the reliability of dose calculations. Especially, for the oral tumor plan, which dealt with dentition and bony structures, treatment planning with the HU-ρ(e) conversion exhibited apparent discrepancies between the dose

  3. Evaluation of two-dimensional bolus effect of immobilization/support devices on skin doses: A radiochromic EBT film dosimetry study in phantom

    Energy Technology Data Exchange (ETDEWEB)

    Chiu-Tsao, Sou-Tung; Chan, Maria F. [Quality MediPhys LLC, 17 Jade Lane, Denville, New Jersey 07834 (United States); Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 136 Mountain View Boulevard, Basking Ridge, New Jersey 07920 (United States)

    2010-07-15

    Purpose: In this study, the authors have quantified the two-dimensional (2D) perspective of skin dose increase using EBT film dosimetry in phantom in the presence of patient immobilization devices during conventional and IMRT treatments. Methods: For 6 MV conventional photon field, the authors evaluated and quantified the 2D bolus effect on skin doses for six different common patient immobilization/support devices, including carbon fiber grid with Mylar sheet, Orfit carbon fiber base plate, balsa wood board, Styrofoam, perforated AquaPlast sheet, and alpha-cradle. For 6 and 15 MV IMRT fields, a stack of two film layers positioned above a solid phantom was exposed at the air interface or in the presence of a patient alpha-cradle. All the films were scanned and the pixel values were converted to doses based on an established calibration curve. The authors determined the 2D skin dose distributions, isodose curves, and cross-sectional profiles at the surface layers with or without the immobilization/support device. The authors also generated and compared the dose area histograms (DAHs) and dose area products from the 2D skin dose distributions. Results: In contrast with 20% relative dose [(RD) dose relative to d{sub max} on central axis] at 0.0153 cm in the film layer for 6 MV 10x10 cm{sup 2} open field, the average RDs at the same depth in the film layer were 71%, 69%, 55%, and 57% for Orfit, balsa wood, Styrofoam, and alpha-cradle, respectively. At the same depth, the RDs were 54% under a strut and 26% between neighboring struts of a carbon fiber grid with Mylar sheet, and between 34% and 56% for stretched perforated AquaPlast sheet. In the presence of the alpha-cradle for the 6 MV (15 MV) IMRT fields, the hot spot doses at the effective measurement depths of 0.0153 and 0.0459 cm were 140% and 150% (83% and 89%), respectively, of the isocenter dose. The enhancement factor was defined as the ratio of a given DAH parameter (minimum dose received in a given area) with

  4. Evaluation of two-dimensional bolus effect of immobilization/support devices on skin doses: a radiochromic EBT film dosimetry study in phantom.

    Science.gov (United States)

    Chiu-Tsao, Sou-Tung; Chan, Maria F

    2010-07-01

    In this study, the authors have quantified the two-dimensional (2D) perspective of skin dose increase using EBT film dosimetry in phantom in the presence of patient immobilization devices during conventional and IMRT treatments. For 6 MV conventional photon field, the authors evaluated and quantified the 2D bolus effect on skin doses for six different common patient immobilization/support devices, including carbon fiber grid with Mylar sheet, Orfit carbon fiber base plate, balsa wood board, Styrofoam, perforated AquaPlast sheet, and alpha-cradle. For 6 and 15 MV IMRT fields, a stack of two film layers positioned above a solid phantom was exposed at the air interface or in the presence of a patient alpha-cradle. All the films were scanned and the pixel values were converted to doses based on an established calibration curve. The authors determined the 2D skin dose distributions, isodose curves, and cross-sectional profiles at the surface layers with or without the immobilization/support device. The authors also generated and compared the dose area histograms (DAHs) and dose area products from the 2D skin dose distributions. In contrast with 20% relative dose [(RD) dose relative to dmax on central axis] at 0.0153 cm in the film layer for 6 MV 10 x 10 cm2 open field, the average RDs at the same depth in the film layer were 71%, 69%, 55%, and 57% for Orfit, balsa wood, Styrofoam, and alpha-cradle, respectively. At the same depth, the RDs were 54% under a strut and 26% between neighboring struts of a carbon fiber grid with Mylar sheet, and between 34% and 56% for stretched perforated AquaPlast sheet. In the presence of the alpha-cradle for the 6 MV (15 MV) IMRT fields, the hot spot doses at the effective measurement depths of 0.0153 and 0.0459 cm were 140% and 150%, (83% and 89%), respectively, of the isocenter dose. The enhancement factor was defined as the ratio of a given DAH parameter (minimum dose received in a given area) with and without the support device. For 6

  5. Quality of routine diagnostic abdominal images generated from a novel detector-based spectral CT scanner: a technical report on a phantom and clinical study.

    Science.gov (United States)

    Hojjati, Mojgan; Van Hedent, Steven; Rassouli, Negin; Tatsuoka, Curtis; Jordan, David; Dhanantwari, Amar; Rajiah, Prabhakar

    2017-11-01

    To evaluate the image quality of routine diagnostic images generated from a novel detector-based spectral detector CT (SDCT) and compare it with CT images obtained from a conventional scanner with an energy-integrating detector (Brilliance iCT), Routine diagnostic (conventional/polyenergetic) images are non-material-specific images that resemble single-energy images obtained at the same radiation, METHODS: ACR guideline-based phantom evaluations were performed on both SDCT and iCT for CT adult body protocol. Retrospective analysis was performed on 50 abdominal CT scans from each scanner. Identical ROIs were placed at multiple locations in the abdomen and attenuation, noise, SNR, and CNR were measured. Subjective image quality analysis on a 5-point Likert scale was performed by 2 readers for enhancement, noise, and image quality. On phantom studies, SDCT images met the ACR requirements for CT number and deviation, CNR and effective radiation dose. In patients, the qualitative scores were significantly higher for the SDCT than the iCT, including enhancement (4.79 ± 0.38 vs. 4.60 ± 0.51, p = 0.005), noise (4.63 ± 0.42 vs. 4.29 ± 0.50, p = 0.000), and quality (4.85 ± 0.32, vs. 4.57 ± 0.50, p = 0.000). The SNR was higher in SDCT than iCT for liver (7.4 ± 4.2 vs. 7.2 ± 5.3, p = 0.662), spleen (8.6 ± 4.1 vs. 7.4 ± 3.5, p = 0.152), kidney (11.1 ± 6.3 vs. 8.7 ± 5.0, p = 0.033), pancreas (6.90 ± 3.45 vs 6.11 ± 2.64, p = 0.303), aorta (14.2 ± 6.2 vs. 11.0 ± 4.9, p = 0.007), but was slightly lower in lumbar-vertebra (7.7 ± 4.2 vs. 7.8 ± 4.5, p = 0.937). The CNR of the SDCT was also higher than iCT for all abdominal organs. Image quality of routine diagnostic images from the SDCT is comparable to images of a conventional CT scanner with energy-integrating detectors, making it suitable for diagnostic purposes.

  6. Towards clinical implementation of ultrafast combined kV-MV CBCT for IGRT of lung cancer. Evaluation of registration accuracy based on phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Arns, Anna; Blessing, Manuel; Fleckenstein, Jens; Stsepankou, Dzmitry; Boda-Heggemann, Judit; Simeonova-Chergou, Anna; Hesser, Juergen; Lohr, Frank; Wenz, Frederik; Wertz, Hansjoerg [University Medical Center Mannheim, University of Heidelberg, Department of Radiation Oncology, Mannheim (German