WorldWideScience

Sample records for virtual slice setup

  1. The virtual slice setup.

    Science.gov (United States)

    Lytton, William W; Neymotin, Samuel A; Hines, Michael L

    2008-06-30

    In an effort to design a simulation environment that is more similar to that of neurophysiology, we introduce a virtual slice setup in the NEURON simulator. The virtual slice setup runs continuously and permits parameter changes, including changes to synaptic weights and time course and to intrinsic cell properties. The virtual slice setup permits shocks to be applied at chosen locations and activity to be sampled intra- or extracellularly from chosen locations. By default, a summed population display is shown during a run to indicate the level of activity and no states are saved. Simulations can run for hours of model time, therefore it is not practical to save all of the state variables. These, in any case, are primarily of interest at discrete times when experiments are being run: the simulation can be stopped momentarily at such times to save activity patterns. The virtual slice setup maintains an automated notebook showing shocks and parameter changes as well as user comments. We demonstrate how interaction with a continuously running simulation encourages experimental prototyping and can suggest additional dynamical features such as ligand wash-in and wash-out-alternatives to typical instantaneous parameter change. The virtual slice setup currently uses event-driven cells and runs at approximately 2 min/h on a laptop.

  2. Resource slicing in virtual wireless networks: a survey

    OpenAIRE

    Richart, Matias; Baliosian De Lazzari, Javier Ernesto; Serrat Fernández, Juan; Gorricho Moreno, Juan Luis

    2016-01-01

    New architectural and design approaches for radio access networks have appeared with the introduction of network virtualization in the wireless domain. One of these approaches splits the wireless network infrastructure into isolated virtual slices under their own management, requirements, and characteristics. Despite the advances in wireless virtualization, there are still many open issues regarding the resource allocation and isolation of wireless slices. Because of the dynamics and share...

  3. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    International Nuclear Information System (INIS)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M.; Welte, T.; Kropf, S.

    2000-01-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  4. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    Energy Technology Data Exchange (ETDEWEB)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M. [Department of Diagnostic Radiology, Otto-von-Guericke University, Magdeburg (Germany); Welte, T. [Department of Cardiology, Angiology, and Pneumology, Otto-von-Guericke University, Magdeburg (Germany); Kropf, S. [Department of Biometrics and Medical Informatics, Otto-von-Guericke University, Magdeburg (Germany)

    2000-06-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  5. Virtual instrument automation of ion channeling setup for 1.7 MV tandetron accelerator

    International Nuclear Information System (INIS)

    Suresh, K.; Sundaravel, B.; Panigrahi, B.K.; Nair, K.G.M.; Viswanathan, B.

    2004-01-01

    A virtual instrument based automated ion channeling experimental setup has been developed and implemented in a 1.7 MV tandetron accelerator. Automation of the PC based setup is done using a windows based virtual instrument software allowing the setup to be easily ported between different computer operating systems. The virtual instrument software has been chosen to achieve quick and easy development of versatile, multi-purpose user friendly graphical interface for carrying out channeling experiments. The software has been modular designed to provide independent control of the stepper motors for fixing the sample at any user defined orientation, running and on-line display of azimuthal and tilt angular scans, auto storage of the angular scan data. Using this automated setup, the crystallographic axis of the sample can be aligned with the incident ion beam rapidly minimizing the beam damages to the sample. A standard single crystalline GaAs(100) has been characterized with this set up using 2 MeV He ++ ion beam. The crystalline quality (χ min ) and channeling half angle (ψ 1sol2 ) are measured to be 3.7% and 0.48 deg., respectively, which are close to the theoretical values. Salient features, working principles and design details of the automated setup are discussed in this paper

  6. USB port compatible virtual instrument based automation for x-ray diffractometer setup

    International Nuclear Information System (INIS)

    Jayapandian, J.; Sheela, O.K.; Mallika, R.; Thiruarul, A.; Purniah, B.

    2004-01-01

    Windows based virtual instrument (VI) programs in graphic language simplify the design automation in R and D laboratories. With minimal hardware and maximum support of software, the automation becomes easier and user friendly. A novel design approach for the automation of SIEMENS make x-ray diffractometer setup is described in this paper. The automation is achieved with an indigenously developed virtual instrument program in labVIEW ver.6.0 and with a simple hardware design using 89C2051 micro-controller compatible with PC's USB port for the total automation of the experiment. (author)

  7. [Simulation and data analysis of stereological modeling based on virtual slices].

    Science.gov (United States)

    Wang, Hao; Shen, Hong; Bai, Xiao-yan

    2008-05-01

    To establish a computer-assisted stereological model for simulating the process of slice section and evaluate the relationship between section surface and estimated three-dimensional structure. The model was designed by mathematic method as a win32 software based on the MFC using Microsoft visual studio as IDE for simulating the infinite process of sections and analysis of the data derived from the model. The linearity of the fitting of the model was evaluated by comparison with the traditional formula. The win32 software based on this algorithm allowed random sectioning of the particles distributed randomly in an ideal virtual cube. The stereological parameters showed very high throughput (>94.5% and 92%) in homogeneity and independence tests. The data of density, shape and size of the section were tested to conform to normal distribution. The output of the model and that from the image analysis system showed statistical correlation and consistency. The algorithm we described can be used for evaluating the stereologic parameters of the structure of tissue slices.

  8. [Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].

    Science.gov (United States)

    Kirchner, J; Laufer, U; Jendreck, M; Kickuth, R; Schilling, E M; Liermann, D

    2000-01-01

    Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.

  9. Experimental demonstration of spectrum-sliced elastic optical path network (SLICE).

    Science.gov (United States)

    Kozicki, Bartłomiej; Takara, Hidehiko; Tsukishima, Yukio; Yoshimatsu, Toshihide; Yonenaga, Kazushige; Jinno, Masahiko

    2010-10-11

    We describe experimental demonstration of spectrum-sliced elastic optical path network (SLICE) architecture. We employ optical orthogonal frequency-division multiplexing (OFDM) modulation format and bandwidth-variable optical cross-connects (OXC) to generate, transmit and receive optical paths with bandwidths of up to 1 Tb/s. We experimentally demonstrate elastic optical path setup and spectrally-efficient transmission of multiple channels with bit rates ranging from 40 to 140 Gb/s between six nodes of a mesh network. We show dynamic bandwidth scalability for optical paths with bit rates of 40 to 440 Gb/s. Moreover, we demonstrate multihop transmission of a 1 Tb/s optical path over 400 km of standard single-mode fiber (SMF). Finally, we investigate the filtering properties and the required guard band width for spectrally-efficient allocation of optical paths in SLICE.

  10. SU-F-P-18: Development of the Technical Training System for Patient Set-Up Considering Rotational Correction in the Virtual Environment Using Three-Dimensional Computer Graphic Engine

    Energy Technology Data Exchange (ETDEWEB)

    Imura, K [Division of Quantum Radiation Science, Department of Health Science, Graduate School of Medical Science, Kyushu University, Fukuoka (Japan); Fujibuchi, T; Hirata, H [Department of Health Science, Graduate School of Medical Science, Kyushu University, Fukuoka (Japan); Kaneko, K [Innovation Center for Educational Resource, Kyushu University, Fukuoka (Japan); Hamada, E [Cancer Treatment Center, Tobata Kyoritsu Hospital, Kitakyushu (Japan)

    2016-06-15

    Purpose: Patient set-up skills in radiotherapy treatment room have a great influence on treatment effect for image guided radiotherapy. In this study, we have developed the training system for improving practical set-up skills considering rotational correction in the virtual environment away from the pressure of actual treatment room by using three-dimensional computer graphic (3DCG) engine. Methods: The treatment room for external beam radiotherapy was reproduced in the virtual environment by using 3DCG engine (Unity). The viewpoints to perform patient set-up in the virtual treatment room were arranged in both sides of the virtual operable treatment couch to assume actual performance by two clinical staffs. The position errors to mechanical isocenter considering alignment between skin marker and laser on the virtual patient model were displayed by utilizing numerical values expressed in SI units and the directions of arrow marks. The rotational errors calculated with a point on the virtual body axis as the center of each rotation axis for the virtual environment were corrected by adjusting rotational position of the body phantom wound the belt with gyroscope preparing on table in a real space. These rotational errors were evaluated by describing vector outer product operations and trigonometric functions in the script for patient set-up technique. Results: The viewpoints in the virtual environment allowed individual user to visually recognize the position discrepancy to mechanical isocenter until eliminating the positional errors of several millimeters. The rotational errors between the two points calculated with the center point could be efficiently corrected to display the minimum technique mathematically by utilizing the script. Conclusion: By utilizing the script to correct the rotational errors as well as accurate positional recognition for patient set-up technique, the training system developed for improving patient set-up skills enabled individual user to

  11. SU-F-P-18: Development of the Technical Training System for Patient Set-Up Considering Rotational Correction in the Virtual Environment Using Three-Dimensional Computer Graphic Engine

    International Nuclear Information System (INIS)

    Imura, K; Fujibuchi, T; Hirata, H; Kaneko, K; Hamada, E

    2016-01-01

    Purpose: Patient set-up skills in radiotherapy treatment room have a great influence on treatment effect for image guided radiotherapy. In this study, we have developed the training system for improving practical set-up skills considering rotational correction in the virtual environment away from the pressure of actual treatment room by using three-dimensional computer graphic (3DCG) engine. Methods: The treatment room for external beam radiotherapy was reproduced in the virtual environment by using 3DCG engine (Unity). The viewpoints to perform patient set-up in the virtual treatment room were arranged in both sides of the virtual operable treatment couch to assume actual performance by two clinical staffs. The position errors to mechanical isocenter considering alignment between skin marker and laser on the virtual patient model were displayed by utilizing numerical values expressed in SI units and the directions of arrow marks. The rotational errors calculated with a point on the virtual body axis as the center of each rotation axis for the virtual environment were corrected by adjusting rotational position of the body phantom wound the belt with gyroscope preparing on table in a real space. These rotational errors were evaluated by describing vector outer product operations and trigonometric functions in the script for patient set-up technique. Results: The viewpoints in the virtual environment allowed individual user to visually recognize the position discrepancy to mechanical isocenter until eliminating the positional errors of several millimeters. The rotational errors between the two points calculated with the center point could be efficiently corrected to display the minimum technique mathematically by utilizing the script. Conclusion: By utilizing the script to correct the rotational errors as well as accurate positional recognition for patient set-up technique, the training system developed for improving patient set-up skills enabled individual user to

  12. A prospective study to determine the need for physical simulation following virtual simulation

    International Nuclear Information System (INIS)

    Valicenti, R.K.; Waterman, F.M.; Corn, B.W.; Sweet, J.; Curran, W.J.

    1996-01-01

    Purpose: Virtual simulation is CT based planning utilizing computed digitally reconstructed radiographs (DRRs) in a manner similar to conventional fluoroscopic simulation. However, conventional or physical simulation is still widely used to assure precise implementation of the devised plan. To evaluate the need for performing physical simulation, we prospectively studied patients undergoing virtual simulation who either had or did not have a subsequent physical simulation. Materials and Methods: From July, 1995 to February, 1996, 48 patients underwent conformal 4-field radiation therapy for prostate cancer using a commercial grade spiral CT simulator. All patients were immobilized in a foam body cast and positioned by using a fiducial laser marking system. Following prostate and seminal vesicle definition on a slice-by-slice basis, virtual simulation was performed. The isocenter defined by this process was marked on both the patient and the immobilization device before leaving the CT simulator room. The isocenter position of the devised plan was evaluated by three verification methods: physical simulation, first day treatment port filming, and port filming immediately following physical simulation. Simulator radiographs and port films were compared against DRRs for x, y, and z deviations of the isocenter. These deviations were used as a measure of the implementation precision achieved by each verification method. Results: Thirty-seven patients underwent physical simulation and first day port filming. Eleven had first day treatment verification films only and never had a physical simulation. A total of 79 simulator radiographs and 126 first day treatment port films were reviewed. The tabulation of all deviations is as follows: There was significantly more setup error (≥ 5 mm) observed when the devised treatment was implemented in the treatment room as opposed to the physical simulator. The physical simulator did not lead to a significant reduction in setup error

  13. The diagnostic value of multi-slice spiral CT virtual bronchoscopy in tracheal and bronchial disease

    International Nuclear Information System (INIS)

    Han Ying; Ma Daqing

    2006-01-01

    Objective: To assess the diagnostic value of multi-slice spiral CT virtual bronchoscopy (CTVB) in tracheal and bronchial disease. Methods: Forty-two patients including central lung cancer (n=35), endobronchial tuberculosis (n=3), intrabronchial benign tumor (n=3), and intrabronchial foreign body (n=1) were examined by using multi-slice spiral CT examinations. All the final diagnosis were proved by pathology except 1 patient with endoluminal foreign body was proved by clinic. All patients were scanned on GE Lightspeed 99 scanner, using 10 mm collimation, pitch of 1.35, and reconstructed at 1 mm intervals and 1.25 mm thickness. The chest images of transverse CT and virtual bronchoscopy were viewed by two separate radiologists who were familiar with the tracheal and bronchial anatomy. Results: Among the 42 patients, the tumor of trachea and bronchial lumen appeared as masses in 22 of 35 patients with central lung cancer and bronchial stenosis was found in 13 of 35 patients with central lung cancer, and bronchial wall thickening was revealed on transverse CT in all 35 cases. 3 patients of endobronchial tuberculosis showed bronchial lumen narrowing on CTVB, the bronchial wall thickening was revealed on transverse CT, and the length of the wall thickening was long. 3 patients with intrabronchial benign tumor showed nodules in trachea and bronchial lumen on CTVB, and without wall thickening on transverse CT. CTVB could detect the occlusion of bronchial lumen in 1 patient with intrabronchial foreign body and CTVB was able to visualize the areas beyond stenosis, and the bronchial wall was without thickening on transverse CT. Conclusion: Multi- slice spiral CTVB could reflect the morphology of tracheal and bronchial disease. Combined with transverse CT, it could provide diagnostic reference value for bronchial disease. (authors)

  14. Perceived spatial positioning of self-footstep sounds in three surround sound speaker setups for immersive virtual reality

    DEFF Research Database (Denmark)

    Sikström, Erik; Nilsson, Niels Christian; Nordahl, Rolf

    2013-01-01

    Are there differences in how well loudspeaker setups are able to provide a believable illusion of footstep sounds originating from the user of an immersive virtual reality? To investigate this performance in spatial positioning via loudspeakers, a comparison of the three surround sound loudspeaker...

  15. Subsurface data visualization in Virtual Reality

    Science.gov (United States)

    Krijnen, Robbert; Smelik, Ruben; Appleton, Rick; van Maanen, Peter-Paul

    2017-04-01

    Due to their increasing complexity and size, visualization of geological data is becoming more and more important. It enables detailed examining and reviewing of large volumes of geological data and it is often used as a communication tool for reporting and education to demonstrate the importance of the geology to policy makers. In the Netherlands two types of nation-wide geological models are available: 1) Layer-based models in which the subsurface is represented by a series of tops and bases of geological or hydrogeological units, and 2) Voxel models in which the subsurface is subdivided in a regular grid of voxels that can contain different properties per voxel. The Geological Survey of the Netherlands (GSN) provides an interactive web portal that delivers maps and vertical cross-sections of such layer-based and voxel models. From this portal you can download a 3D subsurface viewer that can visualize the voxel model data of an area of 20 × 25 km with 100 × 100 × 5 meter voxel resolution on a desktop computer. Virtual Reality (VR) technology enables us to enhance the visualization of this volumetric data in a more natural way as compared to a standard desktop, keyboard mouse setup. The use of VR for data visualization is not new but recent developments has made expensive hardware and complex setups unnecessary. The availability of consumer of-the-shelf VR hardware enabled us to create an new intuitive and low visualization tool. A VR viewer has been implemented using the HTC Vive head set and allows visualization and analysis of the GSN voxel model data with geological or hydrogeological units. The user can navigate freely around the voxel data (20 × 25 km) which is presented in a virtual room at a scale of 2 × 2 or 3 × 3 meters. To enable analysis, e.g. hydraulic conductivity, the user can select filters to remove specific hydrogeological units. The user can also use slicing to cut-off specific sections of the voxel data to get a closer look. This slicing

  16. Geometry Processing of Conventionally Produced Mouse Brain Slice Images.

    Science.gov (United States)

    Agarwal, Nitin; Xu, Xiangmin; Gopi, M

    2018-04-21

    Brain mapping research in most neuroanatomical laboratories relies on conventional processing techniques, which often introduce histological artifacts such as tissue tears and tissue loss. In this paper we present techniques and algorithms for automatic registration and 3D reconstruction of conventionally produced mouse brain slices in a standardized atlas space. This is achieved first by constructing a virtual 3D mouse brain model from annotated slices of Allen Reference Atlas (ARA). Virtual re-slicing of the reconstructed model generates ARA-based slice images corresponding to the microscopic images of histological brain sections. These image pairs are aligned using a geometric approach through contour images. Histological artifacts in the microscopic images are detected and removed using Constrained Delaunay Triangulation before performing global alignment. Finally, non-linear registration is performed by solving Laplace's equation with Dirichlet boundary conditions. Our methods provide significant improvements over previously reported registration techniques for the tested slices in 3D space, especially on slices with significant histological artifacts. Further, as one of the application we count the number of neurons in various anatomical regions using a dataset of 51 microscopic slices from a single mouse brain. To the best of our knowledge the presented work is the first that automatically registers both clean as well as highly damaged high-resolutions histological slices of mouse brain to a 3D annotated reference atlas space. This work represents a significant contribution to this subfield of neuroscience as it provides tools to neuroanatomist for analyzing and processing histological data. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Evaluating Experiences in Different Virtual Reality Setups

    OpenAIRE

    Settgast , Volker; Pirker , Johanna; Lontschar , Stefan; Maggale , Stefan; Gütl , Christian

    2016-01-01

    Part 2: Use and Evaluation of Digital Entertainment; International audience; This paper describes the evaluation of three different scenarios in the fully immersive room-based virtual environment DAVE (Definitely Affordable Virtual Environment) and a head-mounted display, the Oculus Rift. The evaluation focuses on comparing the two immersive environments and three different scenarios (observation, emotion in a roller coaster, and interaction) in regards to typical virtual-reality characterist...

  18. Virtual bronchoscopy

    International Nuclear Information System (INIS)

    Rogalla, P.; Meiri, N.; Hamm, B.; Rueckert, J.C.; Schmidt, B.; Witt, C.

    2001-01-01

    Flexible bronchoscopy represents a clinically well-established invasive diagnostic tool. Virtual bronchoscopies, calculated from thin-slice CT sections, allow astonishing immitations of reality although principal differences exist between both technologies: the Fact that colour representation is artificial and concommitant interventions are impossible limits the clinical use of virtual bronchoscopy. However, its value increases when calculations can be attained within minutes due to technological advancements, and when virtually any chest CT is suitable for further postprocessing. Indications, findings and the clinical role of virtual bronchoscopy are discussed. (orig.) [de

  19. ''Augmented reality'' in conventional simulation by projection of 3-D structures into 2-D images. A comparison with virtual methods

    International Nuclear Information System (INIS)

    Deutschmann, H.; Nairz, O.; Zehentmayr, F.; Fastner, G.; Sedlmayer, F.; Steininger, P.; Kopp, P.; Merz, F.; Wurstbauer, K.; Kranzinger, M.; Kametriser, G.; Kopp, M.

    2008-01-01

    Background and purpose: in this study, a new method is introduced, which allows the overlay of three-dimensional structures, that have been delineated on transverse slices, onto the fluoroscopy from conventional simulators in real time. Patients and methods: setup deviations between volumetric imaging and simulation were visualized, measured and corrected for 701 patient isocenters. Results: comparing the accuracy to mere virtual simulation lacking additional X-ray imaging, a clear benefit of the new method could be shown. On average, virtual prostate simulations had to be corrected by 0.48 cm (standard deviation [SD] 0.38), and those of the breast by 0.67 cm (SD 0.66). Conclusion: the presented method provides an easy way to determine entity-specific safety margins related to patient setup errors upon registration of bony anatomy (prostate 0.9 cm for 90% of cases, breast 1.3 cm). The important role of planar X-ray imaging was clearly demonstrated. The innovation can also be applied to adaptive image-guided radiotherapy (IGRT) protocols. (orig.)

  20. Sixteen-slice multidetector computed tomographic virtual cystoscopy in the evaluation of a patient with suspected bladder tumor and history of bladder carcinoma operation.

    Science.gov (United States)

    Basak, Muzaffer; Ozkurt, Huseyin; Tanriverdi, Orhan; Cay, Esra; Aydin, Mustafa; Miroglu, Cengiz

    2009-01-01

    The purpose of this study was to evaluate the use of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with suspected bladder tumors and histories of bladder carcinoma operation. Thirty-six patients (29 men and 7 women) with a mean age of 66 years (range, 24-88 years) with suspected bladder tumors and histories of bladder carcinoma operation were included in this prospective study. Virtual cystoscopy was performed by 16-slice multidetector CT scanner. The bladder was filled with diluted contrast material solution through a Foley catheter. Then, all patients underwent conventional cystoscopy examination. Two reviewers found 18 lesions detected by virtual cystoscopy by consensus, whereas 19 lesions were depicted by conventional cystoscopy. At virtual and conventional cystoscopies, the conditions of 3 patients, 2 with chronic inflammations and 1 with foreign body reaction, were wrongly diagnosed as tumors. At conventional cystoscopy, one patient's result was wrongly interpreted as normal. In pathologic evaluation, all tumors were diagnosed as transitional cell carcinoma. Bladder tumor can be noninvasively diagnosed using virtual cystoscopy. Use of virtual cystoscopy should be considered inpatients who present with hematuria or have histories of bladder carcinoma operation and are for follow-up because of its lesser complication risk and its being a less invasive, easily applied procedure without need of anesthesia. In the future, owing to the development of the CT technology and image processing technique, virtual cystoscopy may have a part in the detection of bladder cancer.

  1. Meteorological Data Visualization in Multi-User Virtual Reality

    Science.gov (United States)

    Appleton, R.; van Maanen, P. P.; Fisher, W. I.; Krijnen, R.

    2017-12-01

    Due to their complexity and size, visualization of meteorological data is important. It enables the precise examining and reviewing of meteorological details and is used as a communication tool for reporting, education and to demonstrate the importance of the data to policy makers. Specifically for the UCAR community it is important to explore all of such possibilities.Virtual Reality (VR) technology enhances the visualization of volumetric and dynamical data in a more natural way as compared to a standard desktop, keyboard mouse setup. The use of VR for data visualization is not new but recent developments has made expensive hardware and complex setups unnecessary. The availability of consumer of the shelf VR hardware enabled us to create a very intuitive and low cost way to visualize meteorological data. A VR viewer has been implemented using multiple HTC Vive head sets and allows visualization and analysis of meteorological data in NetCDF format (e.g. of NCEP North America Model (NAM), see figure). Sources of atmospheric/meteorological data include radar and satellite as well as traditional weather stations. The data includes typical meteorological information such as temperature, humidity, air pressure, as well as those data described by the climate forecast (CF) model conventions (http://cfconventions.org). Other data such as lightning-strike data and ultra-high-resolution satellite data are also becoming available. The users can navigate freely around the data which is presented in a virtual room at a scale of up to 3.5 X 3.5 meters. The multiple users can manipulate the model simultaneously. Possible mutations include scaling/translating, filtering by value and using a slicing tool to cut-off specific sections of the data to get a closer look. The slicing can be done in any direction using the concept of a `virtual knife' in real-time. The users can also scoop out parts of the data and walk though successive states of the model. Future plans are (a.o.) to

  2. 'Augmented reality' in conventional simulation by projection of 3-D structures into 2-D images. A comparison with virtual methods

    Energy Technology Data Exchange (ETDEWEB)

    Deutschmann, H.; Nairz, O.; Zehentmayr, F.; Fastner, G.; Sedlmayer, F. [Univ. Clinic for Radiotherapy and Radio-Oncology, Salzburg (Austria); radART - Inst. for research and development on Advanced Radiation Technologies at the Paracelsus Medical Univ., Salzburg (Austria); Steininger, P. [radART - Inst. for research and development on Advanced Radiation Technologies at the Paracelsus Medical Univ., Salzburg (Austria); Dept. of Medical Computer Science and Technology, Univ. for Health Sciences, Hall i. T. (Austria); Kopp, P.; Merz, F.; Wurstbauer, K.; Kranzinger, M.; Kametriser, G.; Kopp, M. [Univ. Clinic for Radiotherapy and Radio-Oncology, Salzburg (Austria)

    2008-02-15

    Background and purpose: in this study, a new method is introduced, which allows the overlay of three-dimensional structures, that have been delineated on transverse slices, onto the fluoroscopy from conventional simulators in real time. Patients and methods: setup deviations between volumetric imaging and simulation were visualized, measured and corrected for 701 patient isocenters. Results: comparing the accuracy to mere virtual simulation lacking additional X-ray imaging, a clear benefit of the new method could be shown. On average, virtual prostate simulations had to be corrected by 0.48 cm (standard deviation [SD] 0.38), and those of the breast by 0.67 cm (SD 0.66). Conclusion: the presented method provides an easy way to determine entity-specific safety margins related to patient setup errors upon registration of bony anatomy (prostate 0.9 cm for 90% of cases, breast 1.3 cm). The important role of planar X-ray imaging was clearly demonstrated. The innovation can also be applied to adaptive image-guided radiotherapy (IGRT) protocols. (orig.)

  3. An overview of 5G network slicing architecture

    Science.gov (United States)

    Chen, Qiang; Wang, Xiaolei; Lv, Yingying

    2018-05-01

    With the development of mobile communication technology, the traditional single network model has been unable to meet the needs of users, and the demand for differentiated services is increasing. In order to solve this problem, the fifth generation of mobile communication technology came into being, and as one of the key technologies of 5G, network slice is the core technology of network virtualization and software defined network, enabling network slices to flexibly provide one or more network services according to users' needs[1]. Each slice can independently tailor the network functions according to the requirements of the business scene and the traffic model and manage the layout of the corresponding network resources, to improve the flexibility of network services and the utilization of resources, and enhance the robustness and reliability of the whole network [2].

  4. An architectural framework for virtual enterprise engineering

    DEFF Research Database (Denmark)

    Zwegers, Arian; Hannus, Matti; Tølle, Martin

    2001-01-01

    , especially concerning integration issues. This paper aims to lay down an architectural framework to support the set-up and operation of virtual enterprises. It supports virtual enterprise engineering. The framework might also be used to identify and position issues that play a role in the set......-up and operation of virtual enterprises. As such, it is useful to classify research projects on virtual enterprises as well.......Enterprises cooperate more extensively with other enterprises during the entire product life cycle. Temporary alliances between various enterprises emerge such as those in virtual enterprises. However, many enterprises experience difficulties in the formation and operation of virtual enterprises...

  5. 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images

    International Nuclear Information System (INIS)

    Rodt, T.; Ratiu, P.; Kacher, D.F.; Anderson, M.; Jolesz, F.A.; Kikinis, R.; Becker, H.; Bartling, S.

    2002-01-01

    The 3D imaging of the middle ear facilitates better understanding of the patient's anatomy. Cross-sectional slices, however, often allow a more accurate evaluation of anatomical structures, as some detail may be lost through post-processing. In order to demonstrate the advantages of combining both approaches, we performed computed tomography (CT) imaging in two normal and 15 different pathological cases, and the 3D models were correlated to the cross-sectional CT slices. Reconstructed CT datasets were acquired by multi-slice CT. Post-processing was performed using the in-house software ''3D Slicer'', applying thresholding and manual segmentation. 3D models of the individual anatomical structures were generated and displayed in different colours. The display of relevant anatomical and pathological structures was evaluated in the greyscale 2D slices, 3D images, and the 2D slices showing the segmented 2D anatomy in different colours for each structure. Correlating 2D slices to the 3D models and virtual endoscopy helps to combine the advantages of each method. As generating 3D models can be extremely time-consuming, this approach can be a clinically applicable way of gaining a 3D understanding of the patient's anatomy by using models as a reference. Furthermore, it can help radiologists and otolaryngologists evaluating the 2D slices by adding the correct 3D information that would otherwise have to be mentally integrated. The method can be applied to radiological diagnosis, surgical planning, and especially, to teaching. (orig.)

  6. Visuo-acoustic stimulation that helps you to relax: A virtual reality setup for patients in the intensive care unit.

    Science.gov (United States)

    Gerber, Stephan M; Jeitziner, Marie-Madlen; Wyss, Patric; Chesham, Alvin; Urwyler, Prabitha; Müri, René M; Jakob, Stephan M; Nef, Tobias

    2017-10-16

    After prolonged stay in an intensive care unit (ICU) patients often complain about cognitive impairments that affect health-related quality of life after discharge. The aim of this proof-of-concept study was to test the feasibility and effects of controlled visual and acoustic stimulation in a virtual reality (VR) setup in the ICU. The VR setup consisted of a head-mounted display in combination with an eye tracker and sensors to assess vital signs. The stimulation consisted of videos featuring natural scenes and was tested in 37 healthy participants in the ICU. The VR stimulation led to a reduction of heart rate (p = 0. 049) and blood pressure (p = 0.044). Fixation/saccade ratio (p < 0.001) was increased when a visual target was presented superimposed on the videos (reduced search activity), reflecting enhanced visual processing. Overall, the VR stimulation had a relaxing effect as shown in vital markers of physical stress and participants explored less when attending the target. Our study indicates that VR stimulation in ICU settings is feasible and beneficial for critically ill patients.

  7. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  8. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans

    International Nuclear Information System (INIS)

    Stapleton, S; Zavgorodni, S; Popescu, I A; Beckham, W A

    2005-01-01

    The fluence-convolution method for incorporating random set-up errors (RSE) into the Monte Carlo treatment planning dose calculations was previously proposed by Beckham et al, and it was validated for open field radiotherapy treatments. This study confirms the applicability of the fluence-convolution method for dynamic intensity modulated radiotherapy (IMRT) dose calculations and evaluates the impact of set-up uncertainties on a clinical IMRT dose distribution. BEAMnrc and DOSXYZnrc codes were used for Monte Carlo calculations. A sliding window IMRT delivery was simulated using a dynamic multi-leaf collimator (DMLC) transport model developed by Keall et al. The dose distributions were benchmarked for dynamic IMRT fields using extended dose range (EDR) film, accumulating the dose from 16 subsequent fractions shifted randomly. Agreement of calculated and measured relative dose values was well within statistical uncertainty. A clinical seven field sliding window IMRT head and neck treatment was then simulated and the effects of random set-up errors (standard deviation of 2 mm) were evaluated. The dose-volume histograms calculated in the PTV with and without corrections for RSE showed only small differences indicating a reduction of the volume of high dose region due to set-up errors. As well, it showed that adequate coverage of the PTV was maintained when RSE was incorporated. Slice-by-slice comparison of the dose distributions revealed differences of up to 5.6%. The incorporation of set-up errors altered the position of the hot spot in the plan. This work demonstrated validity of implementation of the fluence-convolution method to dynamic IMRT Monte Carlo dose calculations. It also showed that accounting for the set-up errors could be essential for correct identification of the value and position of the hot spot

  9. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans

    Science.gov (United States)

    Stapleton, S.; Zavgorodni, S.; Popescu, I. A.; Beckham, W. A.

    2005-02-01

    The fluence-convolution method for incorporating random set-up errors (RSE) into the Monte Carlo treatment planning dose calculations was previously proposed by Beckham et al, and it was validated for open field radiotherapy treatments. This study confirms the applicability of the fluence-convolution method for dynamic intensity modulated radiotherapy (IMRT) dose calculations and evaluates the impact of set-up uncertainties on a clinical IMRT dose distribution. BEAMnrc and DOSXYZnrc codes were used for Monte Carlo calculations. A sliding window IMRT delivery was simulated using a dynamic multi-leaf collimator (DMLC) transport model developed by Keall et al. The dose distributions were benchmarked for dynamic IMRT fields using extended dose range (EDR) film, accumulating the dose from 16 subsequent fractions shifted randomly. Agreement of calculated and measured relative dose values was well within statistical uncertainty. A clinical seven field sliding window IMRT head and neck treatment was then simulated and the effects of random set-up errors (standard deviation of 2 mm) were evaluated. The dose-volume histograms calculated in the PTV with and without corrections for RSE showed only small differences indicating a reduction of the volume of high dose region due to set-up errors. As well, it showed that adequate coverage of the PTV was maintained when RSE was incorporated. Slice-by-slice comparison of the dose distributions revealed differences of up to 5.6%. The incorporation of set-up errors altered the position of the hot spot in the plan. This work demonstrated validity of implementation of the fluence-convolution method to dynamic IMRT Monte Carlo dose calculations. It also showed that accounting for the set-up errors could be essential for correct identification of the value and position of the hot spot.

  10. Creating Virtual-hand and Virtual-face Illusions to Investigate Self-representation.

    Science.gov (United States)

    Ma, Ke; Lippelt, Dominique P; Hommel, Bernhard

    2017-03-01

    Studies investigating how people represent themselves and their own body often use variants of "ownership illusions", such as the traditional rubber-hand illusion or the more recently discovered enfacement illusion. However, these examples require rather artificial experimental setups, in which the artificial effector needs to be stroked in synchrony with the participants' real hand or face-a situation in which participants have no control over the stroking or the movements of their real or artificial effector. Here, we describe a technique to establish ownership illusions in a setup that is more realistic, more intuitive, and of presumably higher ecological validity. It allows creating the virtual-hand illusion by having participants control the movements of a virtual hand presented on a screen or in virtual space in front of them. If the virtual hand moves in synchrony with the participants' own real hand, they tend to perceive the virtual hand as part of their own body. The technique also creates the virtual-face illusion by having participants control the movements of a virtual face in front of them, again with the effect that they tend to perceive the face as their own if it moves in synchrony with their real face. Studying the circumstances that illusions of this sort can be created, increased, or reduced provides important information about how people create and maintain representations of themselves.

  11. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  12. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  13. Drying of carrot slices in a triple pass solar dryer

    Directory of Open Access Journals (Sweden)

    Seshachalam Kesavan

    2017-01-01

    Full Text Available An indirect triple pass forced convection solar dryer was developed and its performance was evaluated for drying of carrot slices. The drying experiments were carried out under the meteorological conditions of Coimbatore city in India during the year 2016. The experimental set-up consists of a blower, triple pass packed bed air collector (using sand with wire mesh absorber plate, and a drying chamber. The air mass flow rate was optimized to 0.062 kg/s. The initial moisture content of the carrot slices was reduced from 87.5% (on wet basis to the final moisture content of 10% (wet basis in 6 h duration. The thin layer drying characteristics were analyzed using twelve mathematical models available in open literature. The results showed that the pick-up efficiency of the dryer was varied in the range between 14 and 43% with an average air collector thermal efficiency of 44% during the experimentation. The drying characteristics of carrot slices was predicted with good degree of accuracy using Wang and Singh drying model.

  14. Towards Gesture-Based Multi-User Interactions in Collaborative Virtual Environments

    Science.gov (United States)

    Pretto, N.; Poiesi, F.

    2017-11-01

    We present a virtual reality (VR) setup that enables multiple users to participate in collaborative virtual environments and interact via gestures. A collaborative VR session is established through a network of users that is composed of a server and a set of clients. The server manages the communication amongst clients and is created by one of the users. Each user's VR setup consists of a Head Mounted Display (HMD) for immersive visualisation, a hand tracking system to interact with virtual objects and a single-hand joypad to move in the virtual environment. We use Google Cardboard as a HMD for the VR experience and a Leap Motion for hand tracking, thus making our solution low cost. We evaluate our VR setup though a forensics use case, where real-world objects pertaining to a simulated crime scene are included in a VR environment, acquired using a smartphone-based 3D reconstruction pipeline. Users can interact using virtual gesture-based tools such as pointers and rulers.

  15. Walkable self-overlapping virtual reality maze and map visualization demo

    DEFF Research Database (Denmark)

    Serubugo, Sule; Skantarova, Denisa; Evers, Nicolaj

    2017-01-01

    This paper describes our demonstration of a walkable self-overlapping maze and its corresponding map to facilitate asymmetric collaboration for room-scale virtual reality setups in public places.......This paper describes our demonstration of a walkable self-overlapping maze and its corresponding map to facilitate asymmetric collaboration for room-scale virtual reality setups in public places....

  16. Leading a Virtual Intercultural Team. Implications for Virtual Team Leaders

    OpenAIRE

    Chutnik, Monika; Grzesik, Katarzyna

    2009-01-01

    Increasing number of companies operate in the setup of teams whose members are geographically scattered and have different cultural origins. They work through access to the same digital network and communicate by means of modern technology. Sometimes they are located in different time zones and have never met each other face to face. This is the age of a virtual team leader. Virtual leadership in intercultural groups requires special skills from leaders. Many of these reflect leadership s...

  17. Comparison of classic simulation and virtual simulation in breast irradiation: prospective study on 14 patients

    International Nuclear Information System (INIS)

    Bauduceau, O.; Pons, P.; Romero, L.; Fayolle, M.; Campana, F.; Bollet, M.

    2005-01-01

    Purpose. - To compare conventional 2D simulation and virtual simulation on 14 patients with breast cancer. Patients and methods. - Patients were simulated for treatment using standard procedure. They subsequently underwent CT scan in the treatment position. The CTV was defined as breast tissue. The PTV was obtained by adding a 3D margin of 1 cm around CTV. Organs at risk (lungs and heart) were outlined. Ballistics and dose distribution obtained with the two planning methods were compared. Results. - With conventional simulation, 95% of CTV received 95% of the dose prescribed. Virtual simulation significantly improved dosimetric coverage of PTV without increasing irradiation volume of lung and heart. In 2D simulation, using three slices allowed optimisation by adjusting wedge angle. The five-slice plan was a much better predictor of the maximum dose regions when compared to the three-slice plan. Using entire CT data did not give any benefit. Conclusion. - Variations in CTV delineation and PTV definition limit interest of virtual simulation. In classic simulation, a 5 CT slice-plan can be used to optimise dose distribution. (author)

  18. Optimizing infrastructure for software testing using virtualization

    International Nuclear Information System (INIS)

    Khalid, O.; Shaikh, A.; Copy, B.

    2012-01-01

    Virtualization technology and cloud computing have brought a paradigm shift in the way we utilize, deploy and manage computer resources. They allow fast deployment of multiple operating system as containers on physical machines which can be either discarded after use or check-pointed for later re-deployment. At European Organization for Nuclear Research (CERN), we have been using virtualization technology to quickly setup virtual machines for our developers with pre-configured software to enable them to quickly test/deploy a new version of a software patch for a given application. This paper reports both on the techniques that have been used to setup a private cloud on a commodity hardware and also presents the optimization techniques we used to remove deployment specific performance bottlenecks. (authors)

  19. Virtual networks pluralistic approach for the next generation of Internet

    CERN Document Server

    Duarte, Otto Carlos M B

    2013-01-01

    The first chapter of this title concerns virtualization techniques that allow sharing computational resources basically, slicing a real computational environment into virtual computational environments that are isolated from one another.The Xen and OpenFlow virtualization platforms are then presented in Chapter 2 and a performance analysis of both is provided. This chapter also defines the primitives that the network virtualization infrastructure must provide for allowing the piloting plane to manage virtual network elements.Following this, interfaces for system management of the two platform

  20. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user...... experience studies. We give a description of the experimental setup and the execution of the designed usability and user experience test. To this end, we report interesting results and discuss the results with respect to user-centered design and development of a virtual dressing room....

  1. Measurement of slice sensitivity profile for a 64-slice spiral CT system

    International Nuclear Information System (INIS)

    Liu Chuanya; Qin Weichang; Wang Wei; Lu Chuanyou

    2006-01-01

    Objective: To measure and evaluate slice sensitivity profile (SSP) and the full width at half-maximum(FWHM) for a 64-slice spiral CT system. Methods: Using the same CT technique and body mode as those used for clinical CT, delta phantom was scanned with Somatom Sensation 64-slice spiral CT. SSPs and FWHM were measured both with reconstruction slice width of 0.6 mm at pitch=0.50, 0.75, 1.00, 1.25, 1.50 and with reconstruction slice width of 0.6, 1.0, 1.5 mm at pitch=1 respectively. Results: For normal slice width of 0. 6 mm, the measured FWHM, i.e. effective slice width, is 0.67, 0.67, 0.66, 0.69, 0.69 mm at different pitch. All the measured FWHM deviate less than 0.1 mm from the nominal slice width. The measured SSPs are symmetrical, bell-shaped curves without far-reaching tails, and show only slight variations as a function of the spiral pitch. When reconstruction slice width increase, relative SSP become wider. Conclusions: The variation of pitch hardly has effect all on SSP, effective slice width, and z-direction spatial resolution for Sensation 64-slice spiral CT system, which is helpful to optimize CT scanning protocol. (authors)

  2. Development of Data Acquisition Set-up for Steady-state Experiments

    Science.gov (United States)

    Srivastava, Amit K.; Gupta, Arnab D.; Sunil, S.; Khan, Ziauddin

    2017-04-01

    For short duration experiments, generally digitized data is transferred for processing and storage after the experiment whereas in case of steady-state experiment the data is acquired, processed, displayed and stored continuously in pipelined manner. This requires acquiring data through special techniques for storage and on-the-go viewing data to display the current data trends for various physical parameters. A small data acquisition set-up is developed for continuously acquiring signals from various physical parameters at different sampling rate for long duration experiment. This includes the hardware set-up for signal digitization, Field Programmable Gate Arrays (FPGA) based timing system for clock synchronization and event/trigger distribution, time slicing of data streams for storage of data chunks to enable viewing of data during acquisition and channel profile display through down sampling etc. In order to store a long data stream of indefinite/long time duration, the data stream is divided into data slices/chunks of user defined time duration. Data chunks avoid the problem of non-access of server data until the channel data file is closed at the end of the long duration experiment. A graphical user interface has been developed in Lab VIEW application development environment for configuring the data acquisition hardware and storing data chunks on local machine as well as at remote data server through Python for further data access. The data plotting and analysis utilities have been developed with Python software, which provides tools for further data processing. This paper describes the development and implementation of data acquisition for steady-state experiment.

  3. Thick Slice and Thin Slice Teaching Evaluations

    Science.gov (United States)

    Tom, Gail; Tong, Stephanie Tom; Hesse, Charles

    2010-01-01

    Student-based teaching evaluations are an integral component to institutions of higher education. Previous work on student-based teaching evaluations suggest that evaluations of instructors based upon "thin slice" 30-s video clips of them in the classroom correlate strongly with their end of the term "thick slice" student evaluations. This study's…

  4. Architectural slicing

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Hansen, Klaus Marius

    2013-01-01

    Architectural prototyping is a widely used practice, con- cerned with taking architectural decisions through experiments with light- weight implementations. However, many architectural decisions are only taken when systems are already (partially) implemented. This is prob- lematic in the context...... of architectural prototyping since experiments with full systems are complex and expensive and thus architectural learn- ing is hindered. In this paper, we propose a novel technique for harvest- ing architectural prototypes from existing systems, \\architectural slic- ing", based on dynamic program slicing. Given...... a system and a slicing criterion, architectural slicing produces an architectural prototype that contain the elements in the architecture that are dependent on the ele- ments in the slicing criterion. Furthermore, we present an initial design and implementation of an architectural slicer for Java....

  5. [The virtual reality simulation research of China Mechanical Virtual Human based on the Creator/Vega].

    Science.gov (United States)

    Wei, Gaofeng; Tang, Gang; Fu, Zengliang; Sun, Qiuming; Tian, Feng

    2010-10-01

    The China Mechanical Virtual Human (CMVH) is a human musculoskeletal biomechanical simulation platform based on China Visible Human slice images; it has great realistic application significance. In this paper is introduced the construction method of CMVH 3D models. Then a simulation system solution based on Creator/Vega is put forward for the complex and gigantic data characteristics of the 3D models. At last, combined with MFC technology, the CMVH simulation system is developed and a running simulation scene is given. This paper provides a new way for the virtual reality application of CMVH.

  6. Virtual colonoscopy in paediatric patients

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Lopez, Elba Martin; Capunay, Carlos; Vallejos, Javier; Carrascosa, Jorge

    2010-01-01

    Objective: To determine the usefulness of perspective-filet view for polypoid lesions in paediatric patients in comparison with conventional virtual colonoscopy (VC) analysis and optical colonoscopy. Methods: Sixty-one patients (mean age 5 years old) with a previous episode of rectal bleeding were studied using a 16 slices CT scanner. All patients underwent a colonic preparation. Two acquisitions were done in supine and prone positions with slices of 2 mm thickness; increment 1 mm, 30-50 mA; 90-120 kV. In a workstation an experienced radiologist reviewed images twice. The first read was done using the conventional virtual colonoscopy technique with the evaluation of two-dimensional (2D), three-dimensional (3D) and endoscopical images. Later, in a second session, perspective-filet view was used. It shows a 360 deg. unrolled visualization of the inner colon. The presence, size and location of the lesions were determined. A record of the reading time was made. Results: At per patient evaluation the conventional virtual colonoscopy analysis obtained a sensitivity of 86% and a specificity of 98%. The perspective-filet view obtained a sensitivity of 91% and a specificity of 99%. In the evaluation on a per lesion basis the conventional analysis had a sensitivity of 81% and a specificity of 88%. Perspective-filet view, had a sensitivity of 82% and specificity of 90%. The average total reading time using conventional colonoscopy technique was 18 ± 3 min, versus 4 ± 1 min using the perspective-filet view. Conclusion: Virtual colon dissection with perspective-filet view is more time-efficient than conventional virtual colonoscopy evaluation with correct correlation in results.

  7. A Virtual Commissioning Learning Platform

    DEFF Research Database (Denmark)

    Mortensen, Steffen; Madsen, Ole

    2018-01-01

    The introduction of reconfigurable manufacturing systems (RMS), Industry 4.0 and the associated technologies requires the establishment of new competencies. Towards that goal, Aalborg University (AAU) has developed an Industry 4.0 learning factory, the AAU Smart Production Lab. The AAU Smart...... Production Lab integrates a number of Industry 4.0 technologies for learning and research purposes. One of the many techniques is virtual commissioning. Virtual commissioning uses a virtual plant model and real controllers (PLCs) enabling a full emulation of the manufacturing system for verification. Virtual...... commissioning can lower the commissioning time up to 63%, allowing faster time to market. However, virtual commission is still missing industrial impact one of the reasons being lack of competencies and integration experiences. The paper presents the setup of the virtual commissioning learning platform...

  8. A Geant4 simulation package for the TASISpec experimental detector setup

    Energy Technology Data Exchange (ETDEWEB)

    Sarmiento, L.G., E-mail: lgsarmientop@unal.edu.co [Universidad Nacional de Colombia, Bogota D.C. 111321 (Colombia); Lund University, S-22100 Lund (Sweden); Andersson, L.-L. [University of Liverpool, Oliver Lodge Laboratory, Liverpool L69 7ZE (United Kingdom); Rudolph, D. [Lund University, S-22100 Lund (Sweden)

    2012-03-01

    The experimental detector setup TASISpec (TA SCA in Small Image mode Spectroscopy) comprises composite Ge- and highly segmented Si-detectors. The setup is constructed to provide multi-coincidence spectroscopic data between {gamma}-rays, X-rays, conversion electrons, fission fragments, and {alpha}-particles for heavy and superheavy elements (Z{>=}100). The full array has been virtually constructed using the Geant4 simulation toolkit. The simulations will not only be used to explore the possibilities of the detector setup itself. More important, however, they will also shed light on the nuclear structure of the heaviest elements. This can be done by comparing the simulated detector response of complex decay modes with the experimental data. Such an iterative or 'self-consistent' way to understand experimental observables will provide more reliability when disentangling the data and deducing experimental decay schemes.

  9. Outline and handling manual of experimental data time slice monitoring software 'SLICE'

    International Nuclear Information System (INIS)

    Shirai, Hiroshi; Hirayama, Toshio; Shimizu, Katsuhiro; Tani, Keiji; Azumi, Masafumi; Hirai, Ken-ichiro; Konno, Satoshi; Takase, Keizou.

    1993-02-01

    We have developed a software 'SLICE' which maps various kinds of plasma experimental data measured at the different geometrical position of JT-60U and JFT-2M onto the equilibrium magnetic configuration and treats them as a function of volume averaged minor radius ρ. Experimental data can be handled uniformly by using 'SLICE'. Plenty of commands of 'SLICE' make it easy to process the mapped data. The experimental data measured as line integrated values are also transformed by Abel inversion. The mapped data are fitted to a functional form and saved to the database 'MAPDB'. 'SLICE' can read the data from 'MAPDB' and re-display and transform them. Still more 'SLICE' creates run data of orbit following Monte-Carlo code 'OFMC' and tokamak predictive and interpretation code system 'TOPICS'. This report summarizes an outline and the usage of 'SLICE'. (author)

  10. The effects of slice thickness and reconstructive parameters on VR image quality in multi-slice CT

    International Nuclear Information System (INIS)

    Gao Zhenlong; Wang Qiang; Liu Caixia

    2005-01-01

    Objective: To explore the effects of slice thickness, reconstructive thickness and reconstructive interval on VR image quality in multi-slice CT, in order to select the best slice thickness and reconstructive parameters for the imaging. Methods: Multi-slice CT scan was applied on a rubber dinosaur model with different slice thickness. VR images were reconstructed with different reconstructive thickness and reconstructive interval. Five radiologists were invited to evaluate the quality of the images without knowing anything about the parameters. Results: The slice thickness, reconstructive thickness and reconstructive interval did have effects on VR image quality and the effective degree was different. The effective coefficients were V 1 =1413.033, V 2 =563.733, V 3 =390.533, respectively. The parameters interacted with the others (P<0.05). The smaller of those parameters, the better of the image quality. With a small slice thickness and a reconstructive slice equal to slice thickness, the image quality had no obvious difference when the reconstructive interval was 1/2, 1/3, 1/4 of the slice thickness. Conclusion: A relative small scan slice thickness, a reconstructive slice equal to slice thickness and a reconstructive interval 1/2 of the slice thickness should be selected for the best VR image quality. The image quality depends mostly on the slice thickness. (authors)

  11. Protection of Mission-Critical Applications from Untrusted Execution Environment: Resource Efficient Replication and Migration of Virtual Machines

    Science.gov (United States)

    2015-09-28

    in the same LAN ; this setup resembles the typical setup in a virtualized datacenter where protected and backup hosts are connected by an internal LAN ... Virtual Machines 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA9550-10-1-0393 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Kang G. Shin 5d. PROJECT...Distribution A - Approved for Public Release 13. SUPPLEMENTARY NOTES None 14. ABSTRACT Continuous replication and live migration of Virtual Machines (VMs

  12. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi [Hiroshima Univ. (Japan). Hospital] (and others)

    2002-12-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  13. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    International Nuclear Information System (INIS)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi

    2002-01-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  14. Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction.

    Science.gov (United States)

    den Harder, J Chiel; van Yperen, Gert H; Blume, Ulrike A; Bos, Clemens

    2015-01-01

    Multispectral imaging (MSI) significantly reduces metal artifacts. Yet, especially in techniques that use gradient selection, such as slice encoding for metal artifact correction (SEMAC), a residual ripple artifact may be prominent. Here, an analysis is presented of the ripple artifact and of slice overlap as an approach to reduce the artifact. The ripple artifact was analyzed theoretically to clarify its cause. Slice overlap, conceptually similar to spectral bin overlap in multi-acquisition with variable resonances image combination (MAVRIC), was achieved by reducing the selection gradient and, thus, increasing the slice profile width. Time domain simulations and phantom experiments were performed to validate the analyses and proposed solution. Discontinuities between slices are aggravated by signal displacement in the frequency encoding direction in areas with deviating B0. Specifically, it was demonstrated that ripple artifacts appear only where B0 varies both in-plane and through-plane. Simulations and phantom studies of metal implants confirmed the efficacy of slice overlap to reduce the artifact. The ripple artifact is an important limitation of gradient selection based MSI techniques, and can be understood using the presented simulations. At a scan-time penalty, slice overlap effectively addressed the artifact, thereby improving image quality near metal implants. © 2014 Wiley Periodicals, Inc.

  15. Integration issues in virtual enterprises supported by an architectural framework

    DEFF Research Database (Denmark)

    Zwegers, Arian; Hannus, Matti; Tølle, Martin

    2001-01-01

    enterprises, especially concerning integration issues. This paper lays down an architectural framework, called VERAM, which aims to support the set-up and operation of virtual enterprises. Five different levels of integration are identified. They should all be addressed during the formation of a virtual......Nowadays, enterprises cooperate more extensively with other enterprises during the entire product life cycle. Temporary alliances between various enterprises emerge such as those in Virtual Enterprises. However, many enterprises experience difficulties in the formation and operation of virtual...

  16. X-ray computed tomography for virtually unrolling damaged papyri

    Energy Technology Data Exchange (ETDEWEB)

    Allegra, Dario; Ciliberto, Paolo; Stanco, Filippo [Universita degli Studi di Catania, Dipartimento di Matematica ed Informatica, Catania (Italy); Ciliberto, Enrico [Universita degli Studi di Catania, Dipartimento di Scienze Chimiche, Catania (Italy); Petrillo, Giuseppe; Trombatore, Claudia [Universita degli Studi di Catania, Dipartimento di Scienze Mediche Chirurgiche e Tecnologie Avanzate, Catania (Italy)

    2016-03-15

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet. (orig.)

  17. X-ray computed tomography for virtually unrolling damaged papyri

    Science.gov (United States)

    Allegra, Dario; Ciliberto, Enrico; Ciliberto, Paolo; Petrillo, Giuseppe; Stanco, Filippo; Trombatore, Claudia

    2016-03-01

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet.

  18. X-ray computed tomography for virtually unrolling damaged papyri

    International Nuclear Information System (INIS)

    Allegra, Dario; Ciliberto, Paolo; Stanco, Filippo; Ciliberto, Enrico; Petrillo, Giuseppe; Trombatore, Claudia

    2016-01-01

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet. (orig.)

  19. Wearable Vibrotactile Haptic Device for Stiffness Discrimination during Virtual Interactions

    Directory of Open Access Journals (Sweden)

    Andualem Tadesse Maereg

    2017-09-01

    Full Text Available In this paper, we discuss the development of cost effective, wireless, and wearable vibrotactile haptic device for stiffness perception during an interaction with virtual objects. Our experimental setup consists of haptic device with five vibrotactile actuators, virtual reality environment tailored in Unity 3D integrating the Oculus Rift Head Mounted Display (HMD and the Leap Motion controller. The virtual environment is able to capture touch inputs from users. Interaction forces are then rendered at 500 Hz and fed back to the wearable setup stimulating fingertips with ERM vibrotactile actuators. Amplitude and frequency of vibrations are modulated proportionally to the interaction force to simulate the stiffness of a virtual object. A quantitative and qualitative study is done to compare the discrimination of stiffness on virtual linear spring in three sensory modalities: visual only feedback, tactile only feedback, and their combination. A common psychophysics method called the Two Alternative Forced Choice (2AFC approach is used for quantitative analysis using Just Noticeable Difference (JND and Weber Fractions (WF. According to the psychometric experiment result, average Weber fraction values of 0.39 for visual only feedback was improved to 0.25 by adding the tactile feedback.

  20. Portable Device Slices Thermoplastic Prepregs

    Science.gov (United States)

    Taylor, Beverly A.; Boston, Morton W.; Wilson, Maywood L.

    1993-01-01

    Prepreg slitter designed to slit various widths rapidly by use of slicing bar holding several blades, each capable of slicing strip of preset width in single pass. Produces material evenly sliced and does not contain jagged edges. Used for various applications in such batch processes involving composite materials as press molding and autoclaving, and in such continuous processes as pultrusion. Useful to all manufacturers of thermoplastic composites, and in slicing B-staged thermoset composites.

  1. Performance Comparison for Virtual Impedance Techniques Used in Droop Controlled Islanded Microgrids

    DEFF Research Database (Denmark)

    Micallef, Alexander; Apap, Maurice; Spiteri-Staines, Cyril

    2016-01-01

    ). Virtual impedance loops were proposed in literature to improve the current sharing between the inverters by normalizing the output impedance of the inverters. However, virtual impedance loops have constraints in this respect since the improvement in the current sharing occurs through redistribution...... for a single phase microgrid setup to achieve a fair performance comparison of the different virtual impedance techniques....

  2. Self-Characterstics and Sound in Immersive Virtual Reality

    DEFF Research Database (Denmark)

    Sikström, Erik; Götzen, Amalia De; Serafin, Stefania

    This experiment aimed to investigate whether a user controlling a full body avatar via real time motion tracking in an immersive virtual reality setup, would estimate the weight of the virtual avatar differently if the footstep sounds are manipulated using three different audio filter settings....... The visual appearance of the avatar was available in two sizes. The subjects performed six walks with each audio configuration active once over two ground types. After completing each walk, the participants were asked to estimate the weight of the virtual avatar and the suitability of the audio feedback...

  3. Fresh Slice Self-Seeding and Fresh Slice Harmonic Lasing at LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Amann, J.W. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2018-04-01

    We present results from the successful demonstration of fresh slice self-seeding at the Linac Coherent Light Source (LCLS).* The performance is compared with SASE and regular self-seeding at photon energy of 5.5 keV, resulting in a relative average brightness increase of a factor of 12 and a factor of 2 respectively. Following this proof-of-principle we discuss the forthcoming plans to use the same technique** for fresh slice harmonic lasing in an upcoming experiment. The demonstration of fresh slice harmonic lasing provides an attractive solution for future XFELs aiming to achieve high efficiency, high brightness X-ray pulses at high photon energies (>12 keV).***

  4. Flat slices in Minkowski space

    Science.gov (United States)

    Murchadha, Niall Ó.; Xie, Naqing

    2015-03-01

    Minkowski space, flat spacetime, with a distance measure in natural units of d{{s}2}=-d{{t}2}+d{{x}2}+d{{y}2}+d{{z}2}, or equivalently, with spacetime metric diag(-1, +1, +1, +1), is recognized as a fundamental arena for physics. The Poincaré group, the set of all rigid spacetime rotations and translations, is the symmetry group of Minkowski space. The action of this group preserves the form of the spacetime metric. Each t = constant slice of each preferred coordinate system is flat. We show that there are also nontrivial non-singular representations of Minkowski space with complete flat slices. If the embedding of the flat slices decays appropriately at infinity, the only flat slices are the standard ones. However, if we remove the decay condition, we find non-trivial flat slices with non-vanishing extrinsic curvature. We write out explicitly the coordinate transformation to a frame with such slices.

  5. Operational Range of Several Interface Algorithms for Different Power Hardware-In-The-Loop Setups

    Directory of Open Access Journals (Sweden)

    Ron Brandl

    2017-11-01

    Full Text Available The importance of Power Hardware-in-the-Loop (PHIL experiments is rising more and more over the last decade in the field of power system and components testing. Due to the bidirectional exchange between virtual and physical systems, a true-to-reality interface is essential; however, linking several dynamic systems, stability issues can challenge the experiments, the components under test, and the individuals performing the experiments. Over the time, several interface algorithms (IA have been developed and analyzed, each having different advantages and disadvantages in view of combining virtual simulations with physical power systems. Finally, IA are very specific to the kind of PHIL experiment. This paper investigates the operational range of several IA for specific PHIL setups by calculations, simulations, and measurements. Therefore, a selection of the mainly used respectively optimized IA is mathematically described. The operational range is verified in a PHIL system testing environment. Furthermore, in order to study the influence of different PHIL setups, according to software and hardware impedance, different tests using linear and switching amplifiers are performed.

  6. Effects of Temperature and Slice Thickness on Drying Kinetics of Pumpkin Slices

    OpenAIRE

    Kongdej LIMPAIBOON

    2011-01-01

    Dried pumpkin slice is an alternative crisp food product. In this study, the effects of temperature and slice thickness on the drying characteristics of pumpkin were studied in a lab-scale tray dryer, using hot air temperatures of 55, 60 and 65 °C and 2, 3 and 4 mm slice thickness at a constant air velocity of 1.5 m/s. The initial moisture content of the pumpkin samples was 900.5 % (wb). The drying process was carried out until the final moisture content of product was 100.5 % (wb). The resul...

  7. The Set-Up and Implementation of Fully Virtualized Lessons with an Automated Workflow Utilizing VMC/Moodle at the Medical University of Graz

    Directory of Open Access Journals (Sweden)

    Herwig Erich Rehatschek

    2011-12-01

    Full Text Available With start of winter semester 2010/11 the Medical University of Graz (MUG successfully introduced a new primary learning management system (LMS Moodle. Moodle currently serves more than 4,300 students from three studies and holds more than 7,500 unique learning objects. With begin of the summer semester 2010 we decided to start a pilot with Moodle and 430 students. For the pilot we migrated the learning content of one module and two optional subjects to Moodle. The evaluation results were extremely promising – more than 92% of the students wanted immediately Moodle – also Moodle did meet our high expectations in terms of performance and scalability. Within this paper we describe how we defined and set-up a scalable and highly available platform for hosting Moodle and extended it by the functionality for fully automated virtual lessons. We state our experiences and give valuable clues for universities and institutions who want to introduce Moodle in the near future.

  8. Benchmark test cases for evaluation of computer-based methods for detection of setup errors: realistic digitally reconstructed electronic portal images with known setup errors

    International Nuclear Information System (INIS)

    Fritsch, Daniel S.; Raghavan, Suraj; Boxwala, Aziz; Earnhart, Jon; Tracton, Gregg; Cullip, Timothy; Chaney, Edward L.

    1997-01-01

    Purpose: The purpose of this investigation was to develop methods and software for computing realistic digitally reconstructed electronic portal images with known setup errors for use as benchmark test cases for evaluation and intercomparison of computer-based methods for image matching and detecting setup errors in electronic portal images. Methods and Materials: An existing software tool for computing digitally reconstructed radiographs was modified to compute simulated megavoltage images. An interface was added to allow the user to specify which setup parameter(s) will contain computer-induced random and systematic errors in a reference beam created during virtual simulation. Other software features include options for adding random and structured noise, Gaussian blurring to simulate geometric unsharpness, histogram matching with a 'typical' electronic portal image, specifying individual preferences for the appearance of the 'gold standard' image, and specifying the number of images generated. The visible male computed tomography data set from the National Library of Medicine was used as the planning image. Results: Digitally reconstructed electronic portal images with known setup errors have been generated and used to evaluate our methods for automatic image matching and error detection. Any number of different sets of test cases can be generated to investigate setup errors involving selected setup parameters and anatomic volumes. This approach has proved to be invaluable for determination of error detection sensitivity under ideal (rigid body) conditions and for guiding further development of image matching and error detection methods. Example images have been successfully exported for similar use at other sites. Conclusions: Because absolute truth is known, digitally reconstructed electronic portal images with known setup errors are well suited for evaluation of computer-aided image matching and error detection methods. High-quality planning images, such as

  9. An evaluation of different setups for simulating lighting characteristics

    Science.gov (United States)

    Salters, Bart; Murdoch, Michael; Sekulovksi, Dragan; Chen, Shih-Han; Seuntiens, Pieter

    2012-03-01

    The advance of technology continuously enables new luminaire designs and concepts. Evaluating such designs has traditionally been done using actual prototypes, in a real environment. The iterations needed to build, verify, and improve luminaire designs incur substantial costs and slow down the design process. A more attractive way is to evaluate designs using simulations, as they can be made cheaper and quicker for a wider variety of prototypes. However, the value of such simulations is determined by how closely they predict the outcome of actual perception experiments. In this paper, we discuss an actual perception experiment including several lighting settings in a normal office environment. The same office environment also has been modeled using different software tools, and photo-realistic renderings have been created of these models. These renderings were subsequently processed using various tonemapping operators in preparation for display. The total imaging chain can be considered a simulation setup, and we have executed several perception experiments on different setups. Our real interest is in finding which imaging chain gives us the best result, or in other words, which of them yields the closest match between virtual and real experiment. To answer this question, first of all an answer has to be found to the question, "which simulation setup matches the real world best?" As there is no unique, widely accepted measure to describe the performance of a certain setup, we consider a number of options and discuss the reasoning behind them along with their advantages and disadvantages.

  10. VIRTUAL PURCHASE INTENTION: INFLUENCE OF SECURITY AND TRUST

    OpenAIRE

    Asma javed*, Dr Wasif Ali Waseer, Dr Babak Mehmood

    2018-01-01

    The fast growth of online transaction and e-commerce inspired many companies to setup their business on web pages. It is fact that online purchasing is still poor as compared to other online activities. Research study will explore factors that affect consumer’s virtual purchase intention. Theory of Planned Behavior (TPB), Theory of Reasoned Action (TRA), and Theory Acceptance Model (TAM) are the groundwork theories that are used in research to investigate those factors that affect the virtual...

  11. Induksi Ginogenesis melalui Kultur Multi Ovule Slice dan Kultur Ovary Slice Dianthus chinensis

    Directory of Open Access Journals (Sweden)

    Suskandari Kartikaningrum

    2013-10-01

    Full Text Available Callus induction was studied in five genotypes of Dianthus chinensis using 2.4 D and NAA. Calluses can be obtainedfrom unfertilized ovule culture and ovary culture. The aim of the research was to study gynogenic potential and responseof Dianthus chinensis through ovule slice and ovary slice culture for obtaining haploid plants. Five genotypes of Dianthuschinensis and five media were used in ovule slice culture and two genotypes and three medium were used in ovary culture.Flower buds in the 7th stage were incubated for the purpose of dark pre-treatment at 4 oC for one day. Ovules and ovaries wereisolated and cultured in induction medium. Cultures were incubated for the purpose of dark pre-treatment at 4 oC for seven days, followed by 25 oC light incubation. The result showed that 2.4D was better than NAA in inducing callus. Percentage of regenerated calluses were produced in V11, V13 and V15 genotypes in M7 medium (MS + 2 mg L-1 2.4D + 1 mg L-1 BAP + 30 g L-1 sucrose and M10 medium (MS + 1 mg L-1 2.4D + 1 mg L-1 BAP + 20 g L-1 sucrose. All calluses originated from ovule and ovary cultures flowered prematurely. Double haploid (V11-34 were obtained from ovule slice culture based on PER (peroksidase and EST (esterase isoenzym marker.Keywords: ovule slice culture, ovary slice culture, callus, Dianthus sp., haploid

  12. Clinical application of 16-slice spiral CT in reconstruction imaging of coronary artery for diagnosing coronary disense

    International Nuclear Information System (INIS)

    Mao Xinbo; Zhu Xinjin; Zeng Huiliang; Chen Xueguang

    2005-01-01

    Objective: An evaluation of the reconstructed imaging of coronary arteries with 16-slice spiral CT in diagnosis of coronary disease. Methods: The reconstructed images of coronary arteries obtained on a 16-slice spiral CT scanner were reviewed in 60 cases, on which the following techniques were applied: retrospective ECG-gating, Segment method with 75% R-R interval, volume rendering technique (VRT), maximum intensity projection (MIP), mulfiplanar reconstruction (MPR), curved planar reconstruction (CPR) and CT virtual endoscopy (CTVE). Results: In all 60 cases, different stages of CHD were revealed in 21 cases; none abnormality was found in 33; and images were in poor quality in 2 cases, which was available for diagnosis. There were 4 stents planted in 4 cases: soft plaque suspected in lcase, patent in 2 and occlude in 1. Conclusion: The reconstructed imaging of coronary arteries with 16-slice spiral CT is superior modality in evaluation of severe coronary stenosis, plaques, and the pantency of the intra-luminal stents, which is an efficient and non-invasive imaging in diagnosis of early-stage CHD and screening in high risk population. (authors)

  13. Virtual reality systems for rodents.

    Science.gov (United States)

    Thurley, Kay; Ayaz, Aslı

    2017-02-01

    Over the last decade virtual reality (VR) setups for rodents have been developed and utilized to investigate the neural foundations of behavior. Such VR systems became very popular since they allow the use of state-of-the-art techniques to measure neural activity in behaving rodents that cannot be easily used with classical behavior setups. Here, we provide an overview of rodent VR technologies and review recent results from related research. We discuss commonalities and differences as well as merits and issues of different approaches. A special focus is given to experimental (behavioral) paradigms in use. Finally we comment on possible use cases that may further exploit the potential of VR in rodent research and hence inspire future studies.

  14. A Fully Immersive Set-Up for Remote Interaction and Neurorehabilitation Based on Virtual Body Ownership

    Science.gov (United States)

    Perez-Marcos, Daniel; Solazzi, Massimiliano; Steptoe, William; Oyekoya, Oyewole; Frisoli, Antonio; Weyrich, Tim; Steed, Anthony; Tecchia, Franco; Slater, Mel; Sanchez-Vives, Maria V.

    2012-01-01

    Although telerehabilitation systems represent one of the most technologically appealing clinical solutions for the immediate future, they still present limitations that prevent their standardization. Here we propose an integrated approach that includes three key and novel factors: (a) fully immersive virtual environments, including virtual body representation and ownership; (b) multimodal interaction with remote people and virtual objects including haptic interaction; and (c) a physical representation of the patient at the hospital through embodiment agents (e.g., as a physical robot). The importance of secure and rapid communication between the nodes is also stressed and an example implemented solution is described. Finally, we discuss the proposed approach with reference to the existing literature and systems. PMID:22787454

  15. Setup planning for machining

    CERN Document Server

    Hazarika, Manjuri

    2015-01-01

    Professionals as well as researchers can benefit from this comprehensive introduction into the topic of setup planning, which reflects the latest state of research and gives hands-on examples. Starting with a brief but thorough introduction, this book explains the significance of setup planning in process planning and includes a reflection on its external constraints. Step-by-step the different phases of setup planning are outlined and traditional as well as modern approaches, such as fuzzy logic based setup planning, on the solution of setup planning problems are presented. Three detailed examples of applications provide a clear and accessible insight into the up-to-date techniques and various approaches in setup planning.

  16. A method for patient set-up guidance in radiotherapy using augmented reality

    International Nuclear Information System (INIS)

    Talbot, J.; Meyer, J.; Watts, R.; Grasset, R.

    2009-01-01

    Full text: A system for patient set-up in external beam radiotherapy was developed using Augmented Reality (AR). Live images of the linac treatment couch and patient were obtained with video cameras and displayed on a nearby monitor. A 3D model of the patient's external contour was obtained from planning CT data, and AR tracking software was used to superimpose the model onto the video images in the correct position for treatment. Throughout set-up and treatment, the user can view the monitor and visually confirm that the patient is positioned correctly. To ensure that the virtual contour was displayed in the correct position, a process was devised to register the coordinates of the linac with the camera images. A cube with AR tracking markers attached to its faces was constructed for alignment with the isocentre using room lasers or cone-beam CT. The performance of the system was investigated in a clinical environment by using it to position an anthropomorphic phantom without the aid of additional set-up methods. The positioning errors were determined by means of CBCT and image registration. The translational set-up errors were found to be less than 2.4 mm and the rotational errors less than 0.3 0 . This proof-of-principle study has demonstrated the feasibility of using AR for patient position and pose guidance.

  17. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    International Nuclear Information System (INIS)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M.; Wagstaff, Anne W.; Smeltzer, Matthew P.; Krafft, Axel J.; Hankins, Jane S.

    2017-01-01

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  18. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Wagstaff, Anne W. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Rhodes College, Memphis, TN (United States); University of Alabama at Birmingham School of Medicine, Birmingham, AL (United States); Smeltzer, Matthew P. [St. Jude Children' s Research Hospital, Department of Biostatistics, Memphis, TN (United States); University of Memphis, Division of Epidemiology, Biostatistics, and Environmental Health, School of Public Health, Memphis, TN (United States); Krafft, Axel J. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); University Hospital Center Freiburg, Department of Radiology, Freiburg (Germany); Hankins, Jane S. [St. Jude Children' s Research Hospital, Department of Hematology, Memphis, TN (United States)

    2017-01-15

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  19. Comparison of 640-Slice Multidetector Computed Tomography Versus 32-Slice MDCT for Imaging of the Osteo-odonto-keratoprosthesis Lamina.

    Science.gov (United States)

    Norris, Joseph M; Kishikova, Lyudmila; Avadhanam, Venkata S; Koumellis, Panos; Francis, Ian S; Liu, Christopher S C

    2015-08-01

    To investigate the efficacy of 640-slice multidetector computed tomography (MDCT) for detecting osteo-odonto laminar resorption in the osteo-odonto-keratoprosthesis (OOKP) compared with the current standard 32-slice MDCT. Explanted OOKP laminae and bone-dentine fragments were scanned using 640-slice MDCT (Aquilion ONE; Toshiba) and 32-slice MDCT (LightSpeed Pro32; GE Healthcare). Pertinent comparisons including image quality, radiation dose, and scanning parameters were made. Benefits of 640-slice MDCT over 32-slice MDCT were shown. Key comparisons of 640-slice MDCT versus 32-slice MDCT included the following: percentage difference and correlation coefficient between radiological and anatomical measurements, 1.35% versus 3.67% and 0.9961 versus 0.9882, respectively; dose-length product, 63.50 versus 70.26; rotation time, 0.175 seconds versus 1.000 seconds; and detector coverage width, 16 cm versus 2 cm. Resorption of the osteo-odonto lamina after OOKP surgery can result in potentially sight-threatening complications, hence it warrants regular monitoring and timely intervention. MDCT remains the gold standard for radiological assessment of laminar resorption, which facilitates detection of subtle laminar changes earlier than the onset of clinical signs, thus indicating when preemptive measures can be taken. The 640-slice MDCT exhibits several advantages over traditional 32-slice MDCT. However, such benefits may not offset cost implications, except in rare cases, such as in young patients who might undergo years of radiation exposure.

  20. Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

    International Nuclear Information System (INIS)

    Brix, G.; Nagel, H.D.; Stamm, G.; Veit, R.; Lechel, U.; Griebel, J.; Galanski, M.

    2003-01-01

    Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case. (orig.)

  1. The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method.

    Science.gov (United States)

    Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian

    2016-05-01

    Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Target volume delineation and field setup. A practical guide for conformal and intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nancy Y. [Memorial Sloan-Kettering Cancer Center, New York, NY (United States). Radiation Oncology; Lu, Jiade J. (eds.) [National Univ. Health System, Singapore (Singapore). Dept. of Radiation Oncology; National Univ. of Singapore (Singapore). Dept. of Medicine

    2013-03-01

    Practical handbook on selection and delineation of tumor volumes and fields for conformal radiation therapy, including IMRT. Helpful format facilitating use on a step-by-step basis in daily practice. Designed to ensure accurate coverage of commonly encountered tumors along their routes of spread. This handbook is designed to enable radiation oncologists to appropriately and confidently delineate tumor volumes/fields for conformal radiation therapy, including intensity-modulated radiation therapy (IMRT), in patients with commonly encountered cancers. The orientation of this handbook is entirely practical, in that the focus is on the illustration of clinical target volume (CTV) delineation for each major malignancy. Each chapter provides guidelines and concise knowledge on CTV selection for a particular disease, explains how the anatomy of lymphatic drainage shapes the selection of the target volume, and presents detailed illustrations of volumes, slice by slice, on planning CT images. While the emphasis is on target volume delineation for three-dimensional conformal therapy and IMRT, information is also provided on conventional radiation therapy field setup and planning for certain malignancies for which IMRT is not currently suitable.

  3. Comparison of dosimetric methods for virtual wedge analysis

    International Nuclear Information System (INIS)

    Bailey, M.; Nelson, V.; Collins, O.; West, M.; Holloway, L.; Rajapaske, S.; Arts, J.; Varas, J.; Cho, G.; Hill, R.

    2004-01-01

    Full text: The Siemens Virtual Wedge (Concord, USA) creates wedged beam profile by moving a single collimator jaw across the specified field size whilst varying the dose rate and jaw speed for use in the delivery of radiotherapy treatments. The measurement of the dosimetric characteristics of the Siemens Virtual Wedge poses significant challenges to medical physicists. This study investigates several different methods for measuring and analysing the virtual wedge for data collection for treatment planning systems and ongoing quality assurance. The beam profiles of the Virtual Wedge (VW) were compared using several different dosimetric methods. Open field profiles were measured with Kodak X-Omat V (Rochester, NY, USA) radiographic film and compared with measurements made using the Sun Nuclear Profiler with a Motorized Drive Assembly (MDA) (Melbourne, FL, USA) and the Scanditronix Wellhofer CC13 ionisation chamber and 24 ion Chamber Array (CA24) (Schwarzenbruck, Germany). The resolution of each dosimetric method for open field profiles was determined. The Virtual Wedge profiles were measured with radiographic film the Profiler and the Scanditronix Wellhofer CA 24 ion Chamber Array at 5 different depths. The ease of setup, time taken, analysis and accuracy of measurement were all evaluated to determine the method that would be both appropriate and practical for routine quality assurance of the Virtual Wedge. The open field profiles agreed within ±2% or 2mm for all dosimetric methods. The accuracy of the Profiler and CA24 are limited to half of the step size selected for each of these detectors. For the VW measurements a step size of 2mm was selected for the Profiler and the CA24. The VW profiles for all dosimetric methods agreed within ±2% or 2mm for the main wedged section of the profile. The toe and heel ends of the wedges showed the significant discrepancies dependent upon the dosimetry method used, up to 7% for the toe end with the CA24. The dosimetry of the

  4. Probing the parton densities of virtual photons with the reaction γ*γ → jets at LEP

    International Nuclear Information System (INIS)

    Poetter, B.

    1999-01-01

    We present a next-to-leading order calculation of jet production in γ * γ collisions from e + e - scattering in a region where the virtuality Q 2 of the probing virtual photon is small compared to the transverse jet energy. The calculation is based on the phase-space slicing method. The initial state singularity of the virtual photon is factorized into the structure function of the virtual photon, using the MS-bar factorization scheme for virtual photons. Numerical results are presented for LEP2 conditions. The perturbative stability of the pure direct virtual photon approach is compared to that of including resolved virtual photons in different regions of Q 2 . We make predictions for cross sections which suggest that different parametrizations of virtual photon parton densities should be distinguishable by measurements of jet cross sections at LEP

  5. Dose variations caused by setup errors in intracranial stereotactic radiotherapy: A PRESAGE study

    International Nuclear Information System (INIS)

    Teng, Kieyin; Gagliardi, Frank; Alqathami, Mamdooh; Ackerly, Trevor; Geso, Moshi

    2014-01-01

    Stereotactic radiotherapy (SRT) requires tight margins around the tumor, thus producing a steep dose gradient between the tumor and the surrounding healthy tissue. Any setup errors might become clinically significant. To date, no study has been performed to evaluate the dosimetric variations caused by setup errors with a 3-dimensional dosimeter, the PRESAGE. This research aimed to evaluate the potential effect that setup errors have on the dose distribution of intracranial SRT. Computed tomography (CT) simulation of a CIRS radiosurgery head phantom was performed with 1.25-mm slice thickness. An ideal treatment plan was generated using Brainlab iPlan. A PRESAGE was made for every treatment with and without errors. A prescan using the optical CT scanner was carried out. Before treatment, the phantom was imaged using Brainlab ExacTrac. Actual radiotherapy treatments with and without errors were carried out with the Novalis treatment machine. Postscan was performed with an optical CT scanner to analyze the dose irradiation. The dose variation between treatments with and without errors was determined using a 3-dimensional gamma analysis. Errors are clinically insignificant when the passing ratio of the gamma analysis is 95% and above. Errors were clinically significant when the setup errors exceeded a 0.7-mm translation and a 0.5° rotation. The results showed that a 3-mm translation shift in the superior-inferior (SI), right-left (RL), and anterior-posterior (AP) directions and 2° couch rotation produced a passing ratio of 53.1%. Translational and rotational errors of 1.5 mm and 1°, respectively, generated a passing ratio of 62.2%. Translation shift of 0.7 mm in the directions of SI, RL, and AP and a 0.5° couch rotation produced a passing ratio of 96.2%. Preventing the occurrences of setup errors in intracranial SRT treatment is extremely important as errors greater than 0.7 mm and 0.5° alter the dose distribution. The geometrical displacements affect dose delivery

  6. Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases

    International Nuclear Information System (INIS)

    Herfarth, K.K.; Debus, J.; Lohr, F.; Bahner, M.L.; Fritz, P.; Hoess, A.; Schlegel, W. Ph.D.; Wannenmacher, M.F.

    2000-01-01

    Purpose: Patients with liver metastases might benefit from high-dose conformal radiation therapy. A high accuracy of repositioning and a reduction of target movement are necessary for such an approach. The set-up accuracy of patients with liver metastases treated with stereotactic single dose radiation was evaluated. Methods and Materials: Twenty-four patients with liver metastases were treated with single dose radiation therapy on 26 occasions using a self-developed stereotactic frame. Liver movement was reduced by abdominal pressure. The effectiveness was evaluated under fluoroscopy. CT scans were performed on the planning day and directly before treatment. Representative reference marks were chosen and the coordinates were calculated. In addition, the target displacement was quantitatively evaluated after treatment. Results: Diaphragmal movement was reduced to median 7 mm (range: 3-13 mm). The final set-up accuracy of the body was limited to all of median 1.8 mm in latero-lateral direction (range: 0.3-5.0 mm) and 2.0 mm in anterior-posterior direction (0.8-3.8 mm). Deviations of the body in cranio-caudal direction were always less than the thickness of one CT slice (<5 mm). However, a repositioning was necessary in 16 occasions. The final target shift was median 1.6 mm (0.2-7.0 mm) in latero-lateral and 2.3 mm in anterior-posterior direction (0.0-6.3 mm). The median shift in cranio-caudal direction was 4.4 mm (0.0-10.0 mm). Conclusions: In patients with liver metastases, a high set-up accuracy of the body and the target can be achieved. This allows a high-dose focal radiotherapy of these lesions. However, a control CT scan should be performed directly before therapy to confirm set-up accuracy and possibly prompt necessary corrections

  7. Utilization of Flexible Demand in a Virtual Power Plant Set-Up

    DEFF Research Database (Denmark)

    Thavlov, Anders; Bindner, Henrik W.

    2014-01-01

    High penetration levels from renewable energy sources in large-scale power systems demand a high degree of flexibility in the transmission and distribution system. This paper presents a method for utilization of flexible demand in the low-voltage distribution system using the thermal mass...... of a building to defer power consumption from electric space heating. The power consumption for heating is controlled by an operational virtual power plant, which is sending a set point for requested power consumption to the building management system. An optimization problem is formulated...

  8. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT

    International Nuclear Information System (INIS)

    Desbiolles, Lotus; Leschka, Sebastian; Scheffel, Hans; Husmann, Lars; Garzoli, Elisabeth; Marincek, Borut; Alkadhi, Hatem; Plass, Andre; Gaemperli, Oliver; Kaufmann, Philipp A.

    2007-01-01

    Temporal windows providing the best image quality of different segments and types of coronary artery bypass grafts (CABGs) with 64-slice computed tomography (CT) were evaluated in an experimental set-up. Sixty-four-slice CT with a rotation time of 330 ms was performed in 25 patients (four female; mean age 59.9 years). A total of 84 CABGs (62 individual and 22 sequential grafts) were evaluated, including 28 internal mammary artery (33.3%), one radial artery with sequential grafting (2.4%), and 54 saphenous vein grafts (64.3%). Ten data sets were reconstructed in 10% increments of the RR-interval. Each graft was separated into segments (proximal and distal anastomosis, and body), and CABG types were grouped according to target arteries. Two readers independently assessed image quality of each CABG segment in each temporal window. Diagnostic image quality was found with good inter-observer agreement (kappa=0.62) in 98.5% (202/205) of all graft segments. Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001) and for distal anastomosis to the right coronary compared with other target coronary arteries (P<0.05). Overall, best image quality was found at 60%. Image quality of proximal segments did not significantly vary with the temporal window, whereas for all other segments image quality was significantly better at 60% compared with other temporal windows (P<0.05). Sixty-four-slice CT provides best image quality of various segments and types of CABG at 60% of the RR-interval. (orig.)

  9. Leadership set-up

    DEFF Research Database (Denmark)

    Thude, Bettina Ravnborg; Stenager, Egon; von Plessen, Christian

    2018-01-01

    . Findings: The study found that the leadership set-up did not have any clear influence on interdisciplinary cooperation, as all wards had a high degree of interdisciplinary cooperation independent of which leadership set-up they had. Instead, the authors found a relation between leadership set-up and leader...... could influence legitimacy. Originality/value: The study shows that leadership set-up is not the predominant factor that creates interdisciplinary cooperation; but rather, leader legitimacy also should be considered. Additionally, the study shows that leader legitimacy can be difficult to establish...... and that it cannot be taken for granted. This is something chief executive officers should bear in mind when they plan and implement new leadership structures. Therefore, it would also be useful to look more closely at how to achieve legitimacy in cases where the leader is from a different profession to the staff....

  10. Tumor tissue slice cultures as a platform for analyzing tissue-penetration and biological activities of nanoparticles.

    Science.gov (United States)

    Merz, Lea; Höbel, Sabrina; Kallendrusch, Sonja; Ewe, Alexander; Bechmann, Ingo; Franke, Heike; Merz, Felicitas; Aigner, Achim

    2017-03-01

    The success of therapeutic nanoparticles depends, among others, on their ability to penetrate a tissue for actually reaching the target cells, and their efficient cellular uptake in the context of intact tissue and stroma. Various nanoparticle modifications have been implemented for altering physicochemical and biological properties. Their analysis, however, so far mainly relies on cell culture experiments which only poorly reflect the in vivo situation, or is based on in vivo experiments that are often complicated by whole-body pharmacokinetics and are rather tedious especially when analyzing larger nanoparticle sets. For the more precise analysis of nanoparticle properties at their desired site of action, efficient ex vivo systems closely mimicking in vivo tissue properties are needed. In this paper, we describe the setup of organotypic tumor tissue slice cultures for the analysis of tissue-penetrating properties and biological activities of nanoparticles. As a model system, we employ 350μm thick slice cultures from different tumor xenograft tissues, and analyze modified or non-modified polyethylenimine (PEI) complexes as well as their lipopolyplex derivatives for siRNA delivery. The described conditions for tissue slice preparation and culture ensure excellent tissue preservation for at least 14days, thus allowing for prolonged experimentation and analysis. When using fluorescently labeled siRNA for complex visualization, fluorescence microscopy of cryo-sectioned tissue slices reveals different degrees of nanoparticle tissue penetration, dependent on their surface charge. More importantly, the determination of siRNA-mediated knockdown efficacies of an endogenous target gene, the oncogenic survival factor Survivin, reveals the possibility to accurately assess biological nanoparticle activities in situ, i.e. in living cells in their original environment. Taken together, we establish tumor (xenograft) tissue slices for the accurate and facile ex vivo assessment of

  11. An edge over diagnostic setup

    Directory of Open Access Journals (Sweden)

    Sridhar Kannan

    2017-01-01

    Full Text Available Diagnostic setup proposed by H.D. Kingsley serves as a practical aid in treatment planning and diagnosis. These setups have some inherent shortcomings. A simple technique of duplication of the setups in dental stone can solve problems encountered before as well as provide many other advantages over the conventional procedure. The diagnostic setup is prepared by the conventional method [Figure 1]. An alginate impression is then taken of the setups and poured in dental stone to obtain the derived treatment model [Figure 2]. The same setup can now be further modified for alternate lines of treatment. Subsequently models could then be obtained as required [Figure 3].

  12. Virtual building environments (VBE) - Applying information modeling to buildings

    Energy Technology Data Exchange (ETDEWEB)

    Bazjanac, Vladimir

    2004-06-21

    A Virtual Building Environment (VBE) is a ''place'' where building industry project staffs can get help in creating Building Information Models (BIM) and in the use of virtual buildings. It consists of a group of industry software that is operated by industry experts who are also experts in the use of that software. The purpose of a VBE is to facilitate expert use of appropriate software applications in conjunction with each other to efficiently support multidisciplinary work. This paper defines BIM and virtual buildings, and describes VBE objectives, set-up and characteristics of operation. It informs about the VBE Initiative and the benefits from a couple of early VBE projects.

  13. SU-F-T-642: Sub Millimeter Accurate Setup of More Than Three Vertebrae in Spinal SBRT with 6D Couch

    International Nuclear Information System (INIS)

    Wang, X; Zhao, Z; Yang, J; Yang, J; McAleer, M; Brown, P; Li, J; Ghia, A

    2016-01-01

    Purpose: To assess the initial setup accuracy in treating more than 3 vertebral body levels in spinal SBRT using a 6D couch. Methods: We retrospectively analyzed last 20 spinal SBRT patients (4 cervical, 9 thoracic, 7 lumbar/sacrum) treated in our clinic. These patients in customized immobilization device were treated in 1 or 3 fractions. Initial setup used ExacTrac and Brainlab 6D couch to align target within 1 mm and 1 degree, following by a cone beam CT (CBCT) for verification. Our current standard practice allows treating a maximum of three continuous vertebrae. Here we assess the possibility to achieve sub millimeter setup accuracy for more than three vertebrae by examining the residual error in every slice of CBCT. The CBCT had a range of 17.5 cm, which covered 5 to 9 continuous vertebrae depending on the patient and target location. In the study, CBCT from the 1st fraction treatment was rigidly registered with the planning CT in Pinnacle. The residual setup error of a vertebra was determined by expanding the vertebra contour on the planning CT to be large enough to enclose the corresponding vertebra on CBCT. The margin of the expansion was considered as setup error. Results: Out of the 20 patients analyzed, initial setup accuracy can be achieved within 1 mm for a span of 5 or more vertebrae starting from T2 vertebra to inferior vertebra levels. 2 cervical and 2 upper thoracic patients showed the cervical spine was difficult to achieve sub millimeter accuracy for multi levels without a customized immobilization headrest. Conclusion: If the curvature of spinal columns can be reproduced in customized immobilization device during treatment as simulation, multiple continuous vertebrae can be setup within 1 mm with the use of a 6D couch.

  14. SU-F-T-642: Sub Millimeter Accurate Setup of More Than Three Vertebrae in Spinal SBRT with 6D Couch

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X; Zhao, Z; Yang, J; Yang, J; McAleer, M; Brown, P; Li, J; Ghia, A [MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the initial setup accuracy in treating more than 3 vertebral body levels in spinal SBRT using a 6D couch. Methods: We retrospectively analyzed last 20 spinal SBRT patients (4 cervical, 9 thoracic, 7 lumbar/sacrum) treated in our clinic. These patients in customized immobilization device were treated in 1 or 3 fractions. Initial setup used ExacTrac and Brainlab 6D couch to align target within 1 mm and 1 degree, following by a cone beam CT (CBCT) for verification. Our current standard practice allows treating a maximum of three continuous vertebrae. Here we assess the possibility to achieve sub millimeter setup accuracy for more than three vertebrae by examining the residual error in every slice of CBCT. The CBCT had a range of 17.5 cm, which covered 5 to 9 continuous vertebrae depending on the patient and target location. In the study, CBCT from the 1st fraction treatment was rigidly registered with the planning CT in Pinnacle. The residual setup error of a vertebra was determined by expanding the vertebra contour on the planning CT to be large enough to enclose the corresponding vertebra on CBCT. The margin of the expansion was considered as setup error. Results: Out of the 20 patients analyzed, initial setup accuracy can be achieved within 1 mm for a span of 5 or more vertebrae starting from T2 vertebra to inferior vertebra levels. 2 cervical and 2 upper thoracic patients showed the cervical spine was difficult to achieve sub millimeter accuracy for multi levels without a customized immobilization headrest. Conclusion: If the curvature of spinal columns can be reproduced in customized immobilization device during treatment as simulation, multiple continuous vertebrae can be setup within 1 mm with the use of a 6D couch.

  15. Radiation sterilization and identification of gizzard slices

    International Nuclear Information System (INIS)

    Zhu, S.; Fu, C.; Jiang, W.; Yao, D.; Zhao, K.; Zhang, Y.

    1998-01-01

    An orthogonal test of 4 factors of radiation dose, storage temperature, storage time, and sanitation of cutting places was carried out to optimize the conditions for disinfection of gizzard slices. In the optimized condition, both the sanitary quality and the shelf-life of gizzard slices were improved. To identify irradiated gizzard slices, the sensory change, and the levels of water-soluble nitrogen, amino acid, total volatile basic nitrogen, peroxide value, vitamin C consumption and KMnO 4 consumption were determinated. No significant change was observed except for the color which was light brown on the surface of irradiated slices

  16. Possible applications of the LEAP motion controller for more interactive simulated experiments in augmented or virtual reality

    Science.gov (United States)

    Wozniak, Peter; Vauderwange, Oliver; Mandal, Avikarsha; Javahiraly, Nicolas; Curticapean, Dan

    2016-09-01

    Practical exercises are a crucial part of many curricula. Even simple exercises can improve the understanding of the underlying subject. Most experimental setups require special hardware. To carry out e. g. a lens experiments the students need access to an optical bench, various lenses, light sources, apertures and a screen. In our previous publication we demonstrated the use of augmented reality visualization techniques in order to let the students prepare with a simulated experimental setup. Within the context of our intended blended learning concept we want to utilize augmented or virtual reality techniques for stationary laboratory exercises. Unlike applications running on mobile devices, stationary setups can be extended more easily with additional interfaces and thus allow for more complex interactions and simulations in virtual reality (VR) and augmented reality (AR). The most significant difference is the possibility to allow interactions beyond touching a screen. The LEAP Motion controller is a small inexpensive device that allows for the tracking of the user's hands and fingers in three dimensions. It is conceivable to allow the user to interact with the simulation's virtual elements by the user's very hand position, movement and gesture. In this paper we evaluate possible applications of the LEAP Motion controller for simulated experiments in augmented and virtual reality. We pay particular attention to the devices strengths and weaknesses and want to point out useful and less useful application scenarios.

  17. Slice hyperholomorphic Schur analysis

    CERN Document Server

    Alpay, Daniel; Sabadini, Irene

    2016-01-01

    This book defines and examines the counterpart of Schur functions and Schur analysis in the slice hyperholomorphic setting. It is organized into three parts: the first introduces readers to classical Schur analysis, while the second offers background material on quaternions, slice hyperholomorphic functions, and quaternionic functional analysis. The third part represents the core of the book and explores quaternionic Schur analysis and its various applications. The book includes previously unpublished results and provides the basis for new directions of research.

  18. Application of virtual reality techniques in preoperative surgical planning for intracranial anterior circulation aneurysms

    Directory of Open Access Journals (Sweden)

    Shou-sen WANG

    2012-05-01

    Full Text Available Objective  To investigate the value of virtual reality (VR technique in the surgical planning for anterior circulation aneurysms of Willis circle. Methods  A total of 50 patients with 57 aneurysms confirmed by CT angiography in the anterior circle of Willis were enrolled in this study. In preoperative Hunt-Hess scale, grade Ⅰ was designated in 7 patients, grade Ⅱ in 22, grade Ⅲ in 17, grade Ⅳ in 3, grade Ⅴ in 1 patient. Among the aneurysms, 16 were small (≤5mm in diameter, 28 medium (5-15mm, 10 large (15-25mm and 3 giant (≥25mm in size. The thin-slice head scanning data were achieved by 64-slice spiral CT machine. These data was then transferred into Dextroscope image workstation. The virtual imaging system generated clear and vivid virtual images. We compared the findings between simulation surgical operation and actual operation. Results  VR system make the operator felt "personally on the scene" and was able to communicate with the imaging. It could not only visually display the anatomical structures in three dimensions, but also could simulate some surgical procedures, which basically simulated the same outcome of actual operation. All the 50 patients were successfully treated by microsurgical clipping of main aneurysmal or contributory aneurysmal necks. Conclusions  The surgeons is able to be more confident, and the identification for the complex vascular abnormality is improved by planning operative procedure in virtual-reality environment. The virtual-reality system makes the actual operative procedure more concise, thus it is of positive value in surgery for intracranial aneurysm.

  19. Integrating interface slicing into software engineering processes

    Science.gov (United States)

    Beck, Jon

    1993-01-01

    Interface slicing is a tool which was developed to facilitate software engineering. As previously presented, it was described in terms of its techniques and mechanisms. The integration of interface slicing into specific software engineering activities is considered by discussing a number of potential applications of interface slicing. The applications discussed specifically address the problems, issues, or concerns raised in a previous project. Because a complete interface slicer is still under development, these applications must be phrased in future tenses. Nonetheless, the interface slicing techniques which were presented can be implemented using current compiler and static analysis technology. Whether implemented as a standalone tool or as a module in an integrated development or reverse engineering environment, they require analysis no more complex than that required for current system development environments. By contrast, conventional slicing is a methodology which, while showing much promise and intuitive appeal, has yet to be fully implemented in a production language environment despite 12 years of development.

  20. Virtual planning of dental implant placement using CT double scan-technique - own experience

    International Nuclear Information System (INIS)

    Wojciechowski, W.; Urbanik, A.; Kownacki, P.; Kownacki, S.

    2007-01-01

    The correctness of CT performed with the use of a double-scan technique is the basis for achieving proper quality of 3D reconstructions of the maxilla or mandible and subsequent virtual planning of dental implant placement. The aim of this study was the presentation of the methodology of computed tomography scanning and own experience with the use of the double-scan technique. The study group included 26 individuals who underwent MDCT with a double-scan technique using a MDCT scanner SOMATOM Sensation (Siemens, Germany). The parameters of the examination: slice-collimation 10 x 0.75 mm, slice-thickness 0.75 mm. The first CT scan in the procedure was the scan of the patient wearing a radiological prosthesis and occlusal index, which was followed by a separate scan of the radiological prosthesis. These two CT scans were copied and transferred to PC with Procera Software program (Nobel Biocare, Sweden) where dental implant placement was virtually planned. In all 26 patients, precise three-dimensional reconstructions of the anatomical structure were obtained. In 11 patients, on the basis of the virtual planning, the implant placement was performed, 5 patients were referred to preparatory procedures, that is, restoration of the alveolar process, otolaryngological treatment of the maxillary sinuses. The remaining 10 patients did not qualify to the procedure because of unfavorable anatomical ideation's. Correct computed tomography with double-scan technique enables virtual planning of dental implant placement, on the basis of which the real procedure of implantation can be performed. (author)

  1. A survey of program slicing for software engineering

    Science.gov (United States)

    Beck, Jon

    1993-01-01

    This research concerns program slicing which is used as a tool for program maintainence of software systems. Program slicing decreases the level of effort required to understand and maintain complex software systems. It was first designed as a debugging aid, but it has since been generalized into various tools and extended to include program comprehension, module cohesion estimation, requirements verification, dead code elimination, and maintainence of several software systems, including reverse engineering, parallelization, portability, and reuse component generation. This paper seeks to address and define terminology, theoretical concepts, program representation, different program graphs, developments in static slicing, dynamic slicing, and semantics and mathematical models. Applications for conventional slicing are presented, along with a prognosis of future work in this field.

  2. The relationship between image quality and CT dose index of multi-slice low-dose chest CT

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Shao Jiang; Shi Jingyun; You Zhengqian; Li Shijun; Xue Yongming

    2003-01-01

    Objective: To explore the rationality and possibility of multi-slice low-dose CT scan in the examination of the chest. Methods: (1) X-ray dose index measurement: 120 kV tube voltage, 0.75 s rotation, 8 mm and 3 mm slice thickness, and the tube current setting of 115.0, 40.0, 25.0, and 7.5 mAs were employed in every section. The X-ray radiation dose was measured and compared statistically. (2) phantom measurement of homogeneity and noise: The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm sections, and every slice was scanned using tube current of 115.0, 40.0, 25.0, and 7.5 mAs. Five same regions of interest were measured on every image. The homogeneity and noise level of CT were appraised. (3) The multi-slice low-dose CT in patients: 30 patients with mass and 30 with patch shadow in the lung were selected randomly. The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm slice thickness. 115.0, 40.0, 25.0, 15.0, and 7.5 mAs tube current were employed in each same slice. Otherwise, 15 cases with helical scan were examined using 190, 150, 40, 25, and 15 mAs tube current. The reconstruction images of MIP, MPR, CVR, HRCT, 3D, CT virtual endoscopy, and variety of interval reconstruction were compared. (4) Evaluation of image quality: CT images were evaluated by four doctors using single-blind method, and 3 degrees including normal image, image with few artifact, and image with excessive artifact, were employed and analyzed statistically. Results: (1) The CT dose index with 115.0 mAs tube current exceeded those of 40.0, 25.0, and 7.5 mAs by about 60%, 70%, and 85%, respectively. (2) The phantom measurement showed that the lower of CT dose the lower of homogeneity, the lower of CT dose the higher of noise level. (3) Result of image quality evaluation: The percentage of the normal image had no significant difference between 8 and 3 mm in 115, 40, and 25 mAs (P>0.05). Conclusion: Multi-slice low-dose chest CT technology may protect the patients and guarantee the

  3. Virtual colonoscopy - changes for screening examination?

    International Nuclear Information System (INIS)

    Rust, G.F.; Reiser, M.

    2002-01-01

    In principle, virtual colonoscopy is capable to be used as method for early detection of colorectal cancer (CRC), even if the accuracy of the method and radiation exposure are matters discussion in the radiological community. Virtual colonoscopy is able to detect any pathology which is relevant for early detection of CRC especially when using multislice CT, but also with single slice CT. The diagnosis of small lesions, less than 7 mm in diameter (polyps and flat lesions) is still problematic as it is in conventional colonoscopy. The exposure to x-rays in asymptomatic patients, without any increased risk of developing cancer is highly problematic and should be reduced to a minimum. Using special post processing filters on the volume dataset it can be shown that a tube current of 20 mAs is sufficient without any loss in accuracy. Measurements on the Alderson-phantom showed, that an effective dose exposure of 1.2 mSv is obtained using these reduced mAs values. It has to be differentiated between virtual colonoscopy for early detection of polyps and CRC in individual patients or as a screening examination of a large population. Virtual colonoscopy as a screening examination necessitates reduction of radiation dose, a high degree of automatisation in 3D reconstructions as well as the assessment of the entire mucosa. High risk patients, whom refuse fibreoptic colonoscopy should undergo virtual colonoscopy. Virtual colonoscopy has a good chance to become an accepted tool for general screening, if efficient dose reduction, complete visualization of the colon mucosa and automatisation of the post processing procedures can be achieved. (orig.) [de

  4. Synchronous collaboration of virtual and remote laboratories

    OpenAIRE

    Jara, Carlos A.; Candelas-Herías, Francisco A.; Torres, Fernando; Dormido Bencomo, Sebastián; Esquembre Martínez, Francisco

    2009-01-01

    Virtual and remote laboratories(VRLs) are e-learning resources which enhance the accessibility of experimental setups providing a distance teaching framework which meets the student's hands-on learning needs. In addition, online collaborative communication represents a practical and a constructivist method to transmit the knowledge and experience from the teacher to students, overcoming physical distance and isolation. Thus, the integration of learning environments in the form of VRLs inside ...

  5. RF slice profile effects in magnetic resonance fingerprinting.

    Science.gov (United States)

    Hong, Taehwa; Han, Dongyeob; Kim, Min-Oh; Kim, Dong-Hyun

    2017-09-01

    The radio frequency (RF) slice profile effects on T1 and T2 estimation in magnetic resonance fingerprinting (MRF) are investigated with respect to time-bandwidth product (TBW), flip angle (FA) level and field inhomogeneities. Signal evolutions are generated incorporating the non-ideal slice selective excitation process using Bloch simulation and matched to the original dictionary with and without the non-ideal slice profile taken into account. For validation, phantom and in vivo experiments are performed at 3T. Both simulations and experiments results show that T1 and T2 error from non-ideal slice profile increases with increasing FA level, off-resonance, and low TBW values. Therefore, RF slice profile effects should be compensated for accurate determination of the MR parameters. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. NMR surprizes with thin slices and strong gradients

    Energy Technology Data Exchange (ETDEWEB)

    Gaedke, Achim; Kresse, Benjamin [Institute of Condensed Matter Physics, Technische Universitaet Darmstadt (Germany); Nestle, Nikolaus

    2008-07-01

    In the context of our work on diffusion-relaxation-coupling in thin excited slices, we perform NMR experiments in static magnetic field gradients up to 200 T/m. For slice thicknesses in the range of 10{mu}m, the frequency bandwidth of the excited slices becomes sufficiently narrow that free induction decays (FIDs) become observable despite the presence of the strong static gradient. The observed FIDs were also simulated using standard methods from MRI physics. Possible effects of diffusion during the FID duration are still minor at this slice thickness in water but might become dominant for smaller slices or more diffusive media. Furthermore, the detailed excitation structure of the RF pulses was studied in profiling experiments over the edge of a plane liquid cell. Side lobe effects to the slices will be discussed along with approaches to control them. The spatial resolution achieved in the profiling experiments furthermore allows the identification of thermal expansion phenomena in the NMR magnet. Measures to reduce the temperature drift problems are presented.

  7. Experimental Research of Crosscorrelation-Based Virtual Dynamic Flowmeter

    International Nuclear Information System (INIS)

    Jiang, W L; Sun, H M; Niu, H F; Gao, M

    2006-01-01

    An innovated method for measuring dynamic flow is put forward, and a virtual dynamic flowmeter is established. Basing on the principle of pressure pulse containing the flow information, for the dynamic laminar flow, by means of collecting the pressure signals at two points at interval of L and processing them with crosscorrelation calculation, then the transit time is gained, consequently the average flow rate can be got. This calculation is prosecuted repeatedly according to a certain time step length, thus the average flow rates in each time slice can be acquired. If the step length is decreased to zero, the piecewise average flow rate is approximate to the instant dynamic flow. In order to calibrate the virtual dynamic flowmeter, the unloaded servo cylinder was used for the contrasting experiment. The accuracy and validity of this approach has been proved

  8. Thin slices of child personality: Perceptual, situational, and behavioral contributions.

    Science.gov (United States)

    Tackett, Jennifer L; Herzhoff, Kathrin; Kushner, Shauna C; Rule, Nicholas

    2016-01-01

    The present study examined whether thin-slice ratings of child personality serve as a resource-efficient and theoretically valid measurement of child personality traits. We extended theoretical work on the observability, perceptual accuracy, and situational consistency of childhood personality traits by examining intersource and interjudge agreement, cross-situational consistency, and convergent, divergent, and predictive validity of thin-slice ratings. Forty-five unacquainted independent coders rated 326 children's (ages 8-12) personality in 1 of 15 thin-slice behavioral scenarios (i.e., 3 raters per slice, for over 14,000 independent thin-slice ratings). Mothers, fathers, and children rated children's personality, psychopathology, and competence. We found robust evidence for correlations between thin-slice and mother/father ratings of child personality, within- and across-task consistency of thin-slice ratings, and convergent and divergent validity with psychopathology and competence. Surprisingly, thin-slice ratings were more consistent across situations in this child sample than previously found for adults. Taken together, these results suggest that thin slices are a valid and reliable measure to assess child personality, offering a useful method of measurement beyond questionnaires, helping to address novel questions of personality perception and consistency in childhood. (c) 2016 APA, all rights reserved).

  9. Slices

    KAUST Repository

    McCrae, James

    2011-01-01

    Minimalist object representations or shape-proxies that spark and inspire human perception of shape remain an incompletely understood, yet powerful aspect of visual communication. We explore the use of planar sections, i.e., the contours of intersection of planes with a 3D object, for creating shape abstractions, motivated by their popularity in art and engineering. We first perform a user study to show that humans do define consistent and similar planar section proxies for common objects. Interestingly, we observe a strong correlation between user-defined planes and geometric features of objects. Further we show that the problem of finding the minimum set of planes that capture a set of 3D geometric shape features is both NP-hard and not always the proxy a user would pick. Guided by the principles inferred from our user study, we present an algorithm that progressively selects planes to maximize feature coverage, which in turn influence the selection of subsequent planes. The algorithmic framework easily incorporates various shape features, while their relative importance values are computed and validated from the user study data. We use our algorithm to compute planar slices for various objects, validate their utility towards object abstraction using a second user study, and conclude showing the potential applications of the extracted planar slice shape proxies. © 2011 ACM.

  10. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  11. Correlation of NTD-silicon rod and slice resistivity

    International Nuclear Information System (INIS)

    Wolverton, W.M.

    1984-01-01

    Neutron transmutation doped silicon is an electronic material which presents an opportunity to explore a high level of resistivity characterization. This is due to its excellent uniformity of dopant concentration. Appropriate resistivity measurements on the ingot raw material can be used as a predictor of slice resistivity. Correlation of finished NTD rod (i.e. ingot) resistivity to as-cut slice resistivity (after the sawing process) is addressed in the scope of this paper. Empirical data show that the shift of slice-center resistivity compared to rod-end center resistivity is a function of a new kind of rod radial-resistivity gradient. This function has two domains, and most rods are in domain ''A''. Correlating equations show how to significantly improve the prediction of slice resistivity of rods in domain ''A''. The new rod resistivity specifications have resulted in manufacturing economies in the production of NTD silicon slices

  12. Improved mortar setup technique

    CSIR Research Space (South Africa)

    De Villiers, D

    2008-10-01

    Full Text Available bearing sensor. This concept focuses directly on one of the most cumbersome aspects of a mortar set-up, namely the use of aiming posts. The prismatic mirror and bearing dials is described as well as the required setup procedures. The measurement...

  13. Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography

    International Nuclear Information System (INIS)

    Hsieh Jiang

    2001-01-01

    Multislice computed tomography (MCT) is one of the recent technology advancements in CT. Compared to single slice CT, MCT significantly improves examination time, x-ray tube efficiency, and contrast material utilization. Although the scan mode of MCT is predominately helical, step-and-shoot (axial) scans continue to be an important part of routine clinical protocols. In this paper, we present a detailed investigation on the slice sensitivity profile (SSP) of MCT in the step-and-shoot mode. Our investigation shows that, unlike single slice CT, the SSP for MCT exhibits multiple peaks and valleys resulting from intercell gaps between detector rows. To fully understand the characteristics of the SSP, we developed an analytical model to predict the behavior of MCT. We propose a simple experimental technique that can quickly and accurately measure SSP. The impact of the SSP on image artifacts and low contrast detectability is also investigated

  14. Setup uncertainties in linear accelerator based stereotactic radiosurgery and a derivation of the corresponding setup margin for treatment planning.

    Science.gov (United States)

    Zhang, Mutian; Zhang, Qinghui; Gan, Hua; Li, Sicong; Zhou, Su-min

    2016-02-01

    In the present study, clinical stereotactic radiosurgery (SRS) setup uncertainties from image-guidance data are analyzed, and the corresponding setup margin is estimated for treatment planning purposes. Patients undergoing single-fraction SRS at our institution were localized using invasive head ring or non-invasive thermoplastic masks. Setup discrepancies were obtained from an in-room x-ray patient position monitoring system. Post treatment re-planning using the measured setup errors was performed in order to estimate the individual target margins sufficient to compensate for the actual setup errors. The formula of setup margin for a general SRS patient population was derived by proposing a correlation between the three-dimensional setup error and the required minimal margin. Setup errors of 104 brain lesions were analyzed, in which 81 lesions were treated using an invasive head ring, and 23 were treated using non-invasive masks. In the mask cases with image guidance, the translational setup uncertainties achieved the same level as those in the head ring cases. Re-planning results showed that the margins for individual patients could be smaller than the clinical three-dimensional setup errors. The derivation of setup margin adequate to address the patient setup errors was demonstrated by using the arbitrary planning goal of treating 95% of the lesions with sufficient doses. With image guidance, the patient setup accuracy of mask cases can be comparable to that of invasive head rings. The SRS setup margin can be derived for a patient population with the proposed margin formula to compensate for the institution-specific setup errors. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Mathematical Modeling of Thin Layer Microwave Drying of Taro Slices

    Science.gov (United States)

    Kumar, Vivek; Sharma, H. K.; Singh, K.

    2016-03-01

    The present study investigated the drying kinetics of taro slices precooked in different medium viz water (WC), steam (SC) and Lemon Solution (LC) and dried at different microwave power 360, 540 and 720 W. Drying curves of all precooked slices at all microwave powers showed falling rate period along with a very short accelerating period at the beginning of the drying. At all microwave powers, higher drying rate was observed for LC slices as compared to WC and SC slices. To select a suitable drying curve, seven thin-layer drying models were fitted to the experimental data. The data revealed that the Page model was most adequate in describing the microwave drying behavior of taro slices precooked in different medium. The highest effective moisture diffusivity value of 2.11 × 10-8 m2/s was obtained for LC samples while the lowest 0.83 × 10-8 m2/s was obtained for WC taro slices. The activation energy (E a ) of LC taro slices was lower than the E a of WC and SC taro slices.

  16. Setup Analysis: Combining SMED with Other Tools

    Directory of Open Access Journals (Sweden)

    Stadnicka Dorota

    2015-02-01

    Full Text Available The purpose of this paper is to propose the methodology for the setup analysis, which can be implemented mainly in small and medium enterprises which are not convinced to implement the setups development. The methodology was developed after the research which determined the problem. Companies still have difficulties with a long setup time. Many of them do nothing to decrease this time. A long setup is not a sufficient reason for companies to undertake any actions towards the setup time reduction. To encourage companies to implement SMED it is essential to make some analyses of changeovers in order to discover problems. The methodology proposed can really encourage the management to take a decision about the SMED implementation, and that was verified in a production company. The setup analysis methodology is made up of seven steps. Four of them concern a setups analysis in a chosen area of a company, such as a work stand which is a bottleneck with many setups. The goal is to convince the management to begin actions concerning the setups improvement. The last three steps are related to a certain setup and, there, the goal is to reduce a setup time and the risk of problems which can appear during the setup. In this paper, the tools such as SMED, Pareto analysis, statistical analysis, FMEA and other were used.

  17. Set-up for differential manometers testing

    International Nuclear Information System (INIS)

    Ratushnyj, M.I.; Galkin, Yu.V.; Nechaj, A.G.

    1985-01-01

    Set-up characteristic for controlling and testing metrological characteristics of TPP and NPP differential manometers with extreme pressure drop upto 250 kPa is briefly described. The set-up provides with automatic and manual assignment of values of gauge air pressure with errors of 0.1 and 0.25% correspondingly. The set-up is supplied with standard equipment to measure output signals. Set-up supply is carried out by a one-phase alternating current circuit with 220 V. Air supply is carried out by O.4-0.6 MPa. pressure of a pneumatic system. Application of the set-up increases operating efficiency 5 times while checking and turning differential manometers

  18. Immersive Virtual Reality for Visualization of Abdominal CT.

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A; Bodenheimer, Robert E

    2013-03-28

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two-dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  19. Immersive virtual reality for visualization of abdominal CT

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A.; Bodenheimer, Robert E.

    2013-03-01

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  20. RETROSPECTIVE DETECTION OF INTERLEAVED SLICE ACQUISITION PARAMETERS FROM FMRI DATA

    Science.gov (United States)

    Parker, David; Rotival, Georges; Laine, Andrew; Razlighi, Qolamreza R.

    2015-01-01

    To minimize slice excitation leakage to adjacent slices, interleaved slice acquisition is nowadays performed regularly in fMRI scanners. In interleaved slice acquisition, the number of slices skipped between two consecutive slice acquisitions is often referred to as the ‘interleave parameter’; the loss of this parameter can be catastrophic for the analysis of fMRI data. In this article we present a method to retrospectively detect the interleave parameter and the axis in which it is applied. Our method relies on the smoothness of the temporal-distance correlation function, which becomes disrupted along the axis on which interleaved slice acquisition is applied. We examined this method on simulated and real data in the presence of fMRI artifacts such as physiological noise, motion, etc. We also examined the reliability of this method in detecting different types of interleave parameters and demonstrated an accuracy of about 94% in more than 1000 real fMRI scans. PMID:26161244

  1. Water-activity of dehydrated guava slices sweeteners

    International Nuclear Information System (INIS)

    Ayub, M.; Zeb, A.; Ullah, J.

    2005-01-01

    A study was carried out to investigate the individual and combined effect of caloric sweeteners (sucrose, glucose and fructose) and non-caloric sweeteners (saccharine, cyclamate and aspartame) along with antioxidants (citric acid and ascorbic acid) and chemical preservatives (potassium metabisulphite and potassium sorbate) on the water-activity (a/sub w/) of dehydrated guava slices. Different dilutions of caloric sweeteners (20, 30, 40 and 50 degree brix (bx) and non-caloric sweeteners (equivalent to sucrose sweetness) were used. Guava slices were osmotically dehydrated in these solutions and then dehydrated initially at 0 and then at 60 degree C to final moisture-content of 20-25%. Guava slices prepared with sucrose: glucose 7:3 potassium metabisulphite, ascorbic acid and citric acid produced best quality products, which have minimum (a/sub w/) and best overall sensory characteristics. The analysis showed that treatments and their various concentrations had a significant effect (p=0.05) on (a/sub w/) of dehydrated guava slices. (author)

  2. Interactive Slice of the CMS detector

    CERN Multimedia

    Davis, Siona Ruth

    2016-01-01

    This slice shows a colorful cross-section of the CMS detector with all parts of the detector labelled. Viewers are invited to click on buttons associated with five types of particles to see what happens when each type interacts with the sections of the detector. The five types of particles users can select to send through the slice are muons, electrons, neutral hadrons, charged hadrons and photons. Supplementary information on each type of particles is given. Useful for inclusion into general talks on CMS etc. *Animated CMS "slice" for Powerpoint (Mac & PC) Original version - 2004 Updated version - July 2010 *Six slides required - first is a set of buttons; others are for each particle type (muon, electron, charged/neutral hadron, photon) Recommend putting slide 1 anywhere in your presentation and the rest at the end

  3. Development of a bread slicing machine from locally sourced ...

    African Journals Online (AJOL)

    This paper presents the development of a bread slicing machine which is a mechanical device that is used for slicing bread instead of the crude cumbersome and unhygienic method of manual slicing of bread. In an attempt to facilitate the final processing of bread which is a common daily food requirement of most Nigerians ...

  4. Building a virtual ligand screening pipeline using free software: a survey.

    Science.gov (United States)

    Glaab, Enrico

    2016-03-01

    Virtual screening, the search for bioactive compounds via computational methods, provides a wide range of opportunities to speed up drug development and reduce the associated risks and costs. While virtual screening is already a standard practice in pharmaceutical companies, its applications in preclinical academic research still remain under-exploited, in spite of an increasing availability of dedicated free databases and software tools. In this survey, an overview of recent developments in this field is presented, focusing on free software and data repositories for screening as alternatives to their commercial counterparts, and outlining how available resources can be interlinked into a comprehensive virtual screening pipeline using typical academic computing facilities. Finally, to facilitate the set-up of corresponding pipelines, a downloadable software system is provided, using platform virtualization to integrate pre-installed screening tools and scripts for reproducible application across different operating systems. © The Author 2015. Published by Oxford University Press.

  5. Two-photon calcium imaging in mice navigating a virtual reality environment.

    Science.gov (United States)

    Leinweber, Marcus; Zmarz, Pawel; Buchmann, Peter; Argast, Paul; Hübener, Mark; Bonhoeffer, Tobias; Keller, Georg B

    2014-02-20

    In recent years, two-photon imaging has become an invaluable tool in neuroscience, as it allows for chronic measurement of the activity of genetically identified cells during behavior(1-6). Here we describe methods to perform two-photon imaging in mouse cortex while the animal navigates a virtual reality environment. We focus on the aspects of the experimental procedures that are key to imaging in a behaving animal in a brightly lit virtual environment. The key problems that arise in this experimental setup that we here address are: minimizing brain motion related artifacts, minimizing light leak from the virtual reality projection system, and minimizing laser induced tissue damage. We also provide sample software to control the virtual reality environment and to do pupil tracking. With these procedures and resources it should be possible to convert a conventional two-photon microscope for use in behaving mice.

  6. Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    International Nuclear Information System (INIS)

    Rudat, Volker; Hammoud, Mohamed; Pillay, Yogin; Alaradi, Abdul Aziz; Mohamed, Adel; Altuwaijri, Saleh

    2011-01-01

    The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM). Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT) of the head and neck (n = 31), chest (n = 72), abdomen (n = 15), and pelvis (n = 30) were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV). In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. In patients where high set-up accuracy is desired, daily online verification is highly recommended

  7. Cardiac tissue slices: preparation, handling, and successful optical mapping.

    Science.gov (United States)

    Wang, Ken; Lee, Peter; Mirams, Gary R; Sarathchandra, Padmini; Borg, Thomas K; Gavaghan, David J; Kohl, Peter; Bollensdorff, Christian

    2015-05-01

    Cardiac tissue slices are becoming increasingly popular as a model system for cardiac electrophysiology and pharmacology research and development. Here, we describe in detail the preparation, handling, and optical mapping of transmembrane potential and intracellular free calcium concentration transients (CaT) in ventricular tissue slices from guinea pigs and rabbits. Slices cut in the epicardium-tangential plane contained well-aligned in-slice myocardial cell strands ("fibers") in subepicardial and midmyocardial sections. Cut with a high-precision slow-advancing microtome at a thickness of 350 to 400 μm, tissue slices preserved essential action potential (AP) properties of the precutting Langendorff-perfused heart. We identified the need for a postcutting recovery period of 36 min (guinea pig) and 63 min (rabbit) to reach 97.5% of final steady-state values for AP duration (APD) (identified by exponential fitting). There was no significant difference between the postcutting recovery dynamics in slices obtained using 2,3-butanedione 2-monoxime or blebistatin as electromechanical uncouplers during the cutting process. A rapid increase in APD, seen after cutting, was caused by exposure to ice-cold solution during the slicing procedure, not by tissue injury, differences in uncouplers, or pH-buffers (bicarbonate; HEPES). To characterize intrinsic patterns of CaT, AP, and conduction, a combination of multipoint and field stimulation should be used to avoid misinterpretation based on source-sink effects. In summary, we describe in detail the preparation, mapping, and data analysis approaches for reproducible cardiac tissue slice-based investigations into AP and CaT dynamics. Copyright © 2015 the American Physiological Society.

  8. Virtual reality in advanced medical immersive imaging: a workflow for introducing virtual reality as a supporting tool in medical imaging

    KAUST Repository

    Knodel, Markus M.

    2018-02-27

    Radiologic evaluation of images from computed tomography (CT) or magnetic resonance imaging for diagnostic purposes is based on the analysis of single slices, occasionally supplementing this information with 3D reconstructions as well as surface or volume rendered images. However, due to the complexity of anatomical or pathological structures in biomedical imaging, innovative visualization techniques are required to display morphological characteristics three dimensionally. Virtual reality is a modern tool of representing visual data, The observer has the impression of being “inside” a virtual surrounding, which is referred to as immersive imaging. Such techniques are currently being used in technical applications, e.g. in the automobile industry. Our aim is to introduce a workflow realized within one simple program which processes common image stacks from CT, produces 3D volume and surface reconstruction and rendering, and finally includes the data into a virtual reality device equipped with a motion head tracking cave automatic virtual environment system. Such techniques have the potential to augment the possibilities in non-invasive medical imaging, e.g. for surgical planning or educational purposes to add another dimension for advanced understanding of complex anatomical and pathological structures. To this end, the reconstructions are based on advanced mathematical techniques and the corresponding grids which we can export are intended to form the basis for simulations of mathematical models of the pathogenesis of different diseases.

  9. Virtual hydrology observatory: an immersive visualization of hydrology modeling

    Science.gov (United States)

    Su, Simon; Cruz-Neira, Carolina; Habib, Emad; Gerndt, Andreas

    2009-02-01

    The Virtual Hydrology Observatory will provide students with the ability to observe the integrated hydrology simulation with an instructional interface by using a desktop based or immersive virtual reality setup. It is the goal of the virtual hydrology observatory application to facilitate the introduction of field experience and observational skills into hydrology courses through innovative virtual techniques that mimic activities during actual field visits. The simulation part of the application is developed from the integrated atmospheric forecast model: Weather Research and Forecasting (WRF), and the hydrology model: Gridded Surface/Subsurface Hydrologic Analysis (GSSHA). Both the output from WRF and GSSHA models are then used to generate the final visualization components of the Virtual Hydrology Observatory. The various visualization data processing techniques provided by VTK are 2D Delaunay triangulation and data optimization. Once all the visualization components are generated, they are integrated into the simulation data using VRFlowVis and VR Juggler software toolkit. VR Juggler is used primarily to provide the Virtual Hydrology Observatory application with fully immersive and real time 3D interaction experience; while VRFlowVis provides the integration framework for the hydrologic simulation data, graphical objects and user interaction. A six-sided CAVETM like system is used to run the Virtual Hydrology Observatory to provide the students with a fully immersive experience.

  10. Influence of γ-irradiation on drying of slice potato

    International Nuclear Information System (INIS)

    Wang Jun; Chao Yan; Fu Junjie; Wang Jianping

    2001-01-01

    A new technology is introduced to dry food products by hot-air after pretreated by irradiation. The influence of different dosage of irradiation, temperature of hot air, thickness of the slice potato on the rate of dehydration temperature of irradiated potato were studied. A conclusion is reached that the 3 factors, irradiation dosage, hot-air temperature and thickness of slice potato, affect the rate of dehydration and temperature of slice potato. The higher the dosage is, the greater the rate of dehydration of potato becomes, and the higher the temperature of the slice potato gets. (authors)

  11. Influence of the slice thickness in CT to clinical effect

    International Nuclear Information System (INIS)

    Kimura, Kazue; Katakura, Toshihiko; Ito, Masami; Okuaki, Okihisa; Suzuki, Kenji

    1980-01-01

    CT is a kind of tomography. Therefore, what thickness of tissue is being observed in the picture - this is important in the clinical application of CT. The influence of slice thickness on the pictures, especially its clinical effect, was examined. The apparatus used is EMI CT 5005. For varying the slice thickness, it cannot be any larger than the thickness essential to the apparatus. Therefore, to make it thinner than the essential 14 mm, collimators were specially prepared, which were used on the sides of an X-ray tube and a detector. As basic observation, the revelation ability of form owing to the difference of slice thickness using acryl pipes, and the revelation ability of slice face owing to the difference of slice thickness, were examined. About clinical observation, the results for certain cases of cancer were compared with the CT images for the slice thickness of 14 mm essential to EMI CT 5005 and the slice thickness of 7 mm achieved by means of the collimators. (J.P.N.)

  12. The Impact of Avatar Personalization and Immersion on Virtual Body Ownership, Presence, and Emotional Response.

    Science.gov (United States)

    Waltemate, Thomas; Gall, Dominik; Roth, Daniel; Botsch, Mario; Latoschik, Marc Erich

    2018-04-01

    This article reports the impact of the degree of personalization and individualization of users' avatars as well as the impact of the degree of immersion on typical psychophysical factors in embodied Virtual Environments. We investigated if and how virtual body ownership (including agency), presence, and emotional response are influenced depending on the specific look of users' avatars, which varied between (1) a generic hand-modeled version, (2) a generic scanned version, and (3) an individualized scanned version. The latter two were created using a state-of-the-art photogrammetry method providing a fast 3D-scan and post-process workflow. Users encountered their avatars in a virtual mirror metaphor using two VR setups that provided a varying degree of immersion, (a) a large screen surround projection (L-shape part of a CAVE) and (b) a head-mounted display (HMD). We found several significant as well as a number of notable effects. First, personalized avatars significantly increase body ownership, presence, and dominance compared to their generic counterparts, even if the latter were generated by the same photogrammetry process and hence could be valued as equal in terms of the degree of realism and graphical quality. Second, the degree of immersion significantly increases the body ownership, agency, as well as the feeling of presence. These results substantiate the value of personalized avatars resembling users' real-world appearances as well as the value of the deployed scanning process to generate avatars for VR-setups where the effect strength might be substantial, e.g., in social Virtual Reality (VR) or in medical VR-based therapies relying on embodied interfaces. Additionally, our results also strengthen the value of fully immersive setups which, today, are accessible for a variety of applications due to the widely available consumer HMDs.

  13. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses

    NARCIS (Netherlands)

    Wellenberg, R. H. H.; Boomsma, M. F.; van Osch, J. A. C.; Vlassenbroek, A.; Milles, J.; Edens, M. A.; Streekstra, G. J.; Slump, C. H.; Maas, M.

    2017-01-01

    To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer

  14. Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    Directory of Open Access Journals (Sweden)

    Mohamed Adel

    2011-08-01

    Full Text Available Abstract Purpose The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM. Methods and materials Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT or three-dimensional conformal radiotherapy (3D-CRT of the head and neck (n = 31, chest (n = 72, abdomen (n = 15, and pelvis (n = 30 were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV. In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. Results The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. Conclusion In patients where high set-up accuracy is desired, daily online verification is highly recommended.

  15. Software platform virtualization in chemistry research and university teaching.

    Science.gov (United States)

    Kind, Tobias; Leamy, Tim; Leary, Julie A; Fiehn, Oliver

    2009-11-16

    Modern chemistry laboratories operate with a wide range of software applications under different operating systems, such as Windows, LINUX or Mac OS X. Instead of installing software on different computers it is possible to install those applications on a single computer using Virtual Machine software. Software platform virtualization allows a single guest operating system to execute multiple other operating systems on the same computer. We apply and discuss the use of virtual machines in chemistry research and teaching laboratories. Virtual machines are commonly used for cheminformatics software development and testing. Benchmarking multiple chemistry software packages we have confirmed that the computational speed penalty for using virtual machines is low and around 5% to 10%. Software virtualization in a teaching environment allows faster deployment and easy use of commercial and open source software in hands-on computer teaching labs. Software virtualization in chemistry, mass spectrometry and cheminformatics is needed for software testing and development of software for different operating systems. In order to obtain maximum performance the virtualization software should be multi-core enabled and allow the use of multiprocessor configurations in the virtual machine environment. Server consolidation, by running multiple tasks and operating systems on a single physical machine, can lead to lower maintenance and hardware costs especially in small research labs. The use of virtual machines can prevent software virus infections and security breaches when used as a sandbox system for internet access and software testing. Complex software setups can be created with virtual machines and are easily deployed later to multiple computers for hands-on teaching classes. We discuss the popularity of bioinformatics compared to cheminformatics as well as the missing cheminformatics education at universities worldwide.

  16. The topology of large-scale structure. VI - Slices of the universe

    Science.gov (United States)

    Park, Changbom; Gott, J. R., III; Melott, Adrian L.; Karachentsev, I. D.

    1992-03-01

    Results of an investigation of the topology of large-scale structure in two observed slices of the universe are presented. Both slices pass through the Coma cluster and their depths are 100 and 230/h Mpc. The present topology study shows that the largest void in the CfA slice is divided into two smaller voids by a statistically significant line of galaxies. The topology of toy models like the white noise and bubble models is shown to be inconsistent with that of the observed slices. A large N-body simulation was made of the biased cloud dark matter model and the slices are simulated by matching them in selection functions and boundary conditions. The genus curves for these simulated slices are spongelike and have a small shift in the direction of a meatball topology like those of observed slices.

  17. The topology of large-scale structure. VI - Slices of the universe

    Science.gov (United States)

    Park, Changbom; Gott, J. R., III; Melott, Adrian L.; Karachentsev, I. D.

    1992-01-01

    Results of an investigation of the topology of large-scale structure in two observed slices of the universe are presented. Both slices pass through the Coma cluster and their depths are 100 and 230/h Mpc. The present topology study shows that the largest void in the CfA slice is divided into two smaller voids by a statistically significant line of galaxies. The topology of toy models like the white noise and bubble models is shown to be inconsistent with that of the observed slices. A large N-body simulation was made of the biased cloud dark matter model and the slices are simulated by matching them in selection functions and boundary conditions. The genus curves for these simulated slices are spongelike and have a small shift in the direction of a meatball topology like those of observed slices.

  18. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  19. Representation of Patients' Hand Modulates Fear Reactions of Patients with Spider Phobia in Virtual Reality.

    Science.gov (United States)

    Peperkorn, Henrik M; Diemer, Julia E; Alpers, Georg W; Mühlberger, Andreas

    2016-01-01

    Embodiment (i.e., the involvement of a bodily representation) is thought to be relevant in emotional experiences. Virtual reality (VR) is a capable means of activating phobic fear in patients. The representation of the patient's body (e.g., the right hand) in VR enhances immersion and increases presence, but its effect on phobic fear is still unknown. We analyzed the influence of the presentation of the participant's hand in VR on presence and fear responses in 32 women with spider phobia and 32 matched controls. Participants sat in front of a table with an acrylic glass container within reaching distance. During the experiment this setup was concealed by a head-mounted display (HMD). The VR scenario presented via HMD showed the same setup, i.e., a table with an acrylic glass container. Participants were randomly assigned to one of two experimental groups. In one group, fear responses were triggered by fear-relevant visual input in VR (virtual spider in the virtual acrylic glass container), while information about a real but unseen neutral control animal (living snake in the acrylic glass container) was given. The second group received fear-relevant information of the real but unseen situation (living spider in the acrylic glass container), but visual input was kept neutral VR (virtual snake in the virtual acrylic glass container). Participants were instructed to touch the acrylic glass container with their right hand in 20 consecutive trials. Visibility of the hand was varied randomly in a within-subjects design. We found for all participants that visibility of the participant's hand increased presence independently of the fear trigger. However, in patients, the influence of the virtual hand on fear depended on the fear trigger. When fear was triggered perceptually, i.e., by a virtual spider, the virtual hand increased fear. When fear was triggered by information about a real spider, the virtual hand had no effect on fear. Our results shed light on the

  20. Liberating Virtual Machines from Physical Boundaries through Execution Knowledge

    Science.gov (United States)

    2015-12-01

    trivial infrastructures such as VM distribution networks, clients need to wait for an extended period of time before launching a VM. In cloud settings...hardware support. MobiDesk [28] efficiently supports virtual desktops in mobile environments by decou- pling the user’s workload from host systems and...experiment set-up. VMs are migrated between a pair of source and destination hosts, which are connected through a backend 10 Gbps network for

  1. ASD FieldSpec Calibration Setup and Techniques

    Science.gov (United States)

    Olive, Dan

    2001-01-01

    This paper describes the Analytical Spectral Devices (ASD) Fieldspec Calibration Setup and Techniques. The topics include: 1) ASD Fieldspec FR Spectroradiometer; 2) Components of Calibration; 3) Equipment list; 4) Spectral Setup; 5) Spectral Calibration; 6) Radiometric and Linearity Setup; 7) Radiometric setup; 8) Datadets Required; 9) Data files; and 10) Field of View Measurement. This paper is in viewgraph form.

  2. Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: Comparison with conventional tube-voltage images.

    Science.gov (United States)

    Sakabe, Daisuke; Funama, Yoshinori; Taguchi, Katsuyuki; Nakaura, Takeshi; Utsunomiya, Daisuke; Oda, Seitaro; Kidoh, Masafumi; Nagayama, Yasunori; Yamashita, Yasuyuki

    2018-05-01

    To investigate the image quality characteristics for virtual monoenergetic images compared with conventional tube-voltage image with dual-layer spectral CT (DLCT). Helical scans were performed using a first-generation DLCT scanner, two different sizes of acrylic cylindrical phantoms, and a Catphan phantom. Three different iodine concentrations were inserted into the phantom center. The single-tube voltage for obtaining virtual monoenergetic images was set to 120 or 140 kVp. Conventional 120- and 140-kVp images and virtual monoenergetic images (40-200-keV images) were reconstructed from slice thicknesses of 1.0 mm. The CT number and image noise were measured for each iodine concentration and water on the 120-kVp images and virtual monoenergetic images. The noise power spectrum (NPS) was also calculated. The iodine CT numbers for the iodinated enhancing materials were similar regardless of phantom size and acquisition method. Compared with the iodine CT numbers of the conventional 120-kVp images, those for the monoenergetic 40-, 50-, and 60-keV images increased by approximately 3.0-, 1.9-, and 1.3-fold, respectively. The image noise values for each virtual monoenergetic image were similar (for example, 24.6 HU at 40 keV and 23.3 HU at 200 keV obtained at 120 kVp and 30-cm phantom size). The NPS curves of the 70-keV and 120-kVp images for a 1.0-mm slice thickness over the entire frequency range were similar. Virtual monoenergetic images represent stable image noise over the entire energy spectrum and improved the contrast-to-noise ratio than conventional tube voltage using the dual-layer spectral detector CT. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Multi-Sensory-Motor Research: Investigating Auditory, Visual, and Motor Interaction in Virtual Reality Environments

    Directory of Open Access Journals (Sweden)

    Thorsten Kluss

    2011-10-01

    Full Text Available Perception in natural environments is inseparably linked to motor action. In fact, we consider action an essential component of perceptual representation. But these representations are inherently difficult to investigate: Traditional experimental setups are limited by the lack of flexibility in manipulating spatial features. To overcome these problems, virtual reality (VR experiments seem to be a feasible alternative, but these setups typically lack ecological realism due to the use of “unnatural” interface-devices (joystick. Thus, we propose an experimental apparatus which combines multisensory perception and action in an ecologically realistic way. The basis is a 10-foot hollow sphere (VirtuSphere placed on a platform that allows free rotation. A subject inside can walk in any direction for any distance immersed into virtual environment. Both the rotation of the sphere and movement of the subject's head are tracked to process the subject's view within the VR-environment presented on a head-mounted display. Moreover, auditory features are dynamically processed taking greatest care of exact alignment of sound-sources and visual objects using ambisonic-encoded audio processed by a HRTF-filterbank. We present empirical data that confirm ecological realism of this setup and discuss its suitability for multi-sensory-motor research.

  4. Virtual laboratory for radiation experiments

    International Nuclear Information System (INIS)

    Tiftikci, A.; Kocar, C.; Tombakoglu, M.

    2009-01-01

    Simulation of alpha, beta and gamma radiation detection and measurement experiments which are part of real nuclear physics laboratory courses was realized with Monte Carlo method and JAVA Programming Language. As being known, establishing this type of laboratories are very expensive. At the same time, highly radioactive sources used in some experiments carries risk for students and also for experimentalists. By taking into consideration of those problems, the aim of this study is to setup a virtual radiation laboratory with minimum cost and to speed up the training of radiation physics for students with no radiation risk. Software coded possesses the nature of radiation and radiation transport with the help of Monte Carlo method. In this software, experimental parameters can be changed manually by the user and experimental results can be followed synchronous in an MCA (Multi Channel Analyzer) or an SCA (Single Channel Analyzer). Results obtained in experiments can be analyzed by these MCA or SCA panels. Virtual radiation laboratory which is developed in this study with reliable results and unlimited experimentation capability seems as an useful educational material. Moreover, new type of experiments can be integrated to this software easily and as a result, virtual laboratory can be extended.

  5. Introduction to bit slices and microprogramming

    International Nuclear Information System (INIS)

    Van Dam, A.

    1981-01-01

    Bit-slice logic blocks are fourth-generation LSI components which are natural extensions of traditional mulitplexers, registers, decoders, counters, ALUs, etc. Their functionality is controlled by microprogramming, typically to implement CPUs and peripheral controllers where both speed and easy programmability are required for flexibility, ease of implementation and debugging, etc. Processors built from bit-slice logic give the designer an alternative for approaching the programmibility of traditional fixed-instruction-set microprocessors with a speed closer to that of hardwired random logic. (orig.)

  6. Gravitational collapse of charged dust shell and maximal slicing condition

    International Nuclear Information System (INIS)

    Maeda, Keiichi

    1980-01-01

    The maximal slicing condition is a good time coordinate condition qualitatively when pursuing the gravitational collapse by the numerical calculation. The analytic solution of the gravitational collapse under the maximal slicing condition is given in the case of a spherical charged dust shell and the behavior of time slices with this coordinate condition is investigated. It is concluded that under the maximal slicing condition we can pursue the gravitational collapse until the radius of the shell decreases to about 0.7 x (the radius of the event horizon). (author)

  7. Preservation of low slice emittance in bunch compressors

    Directory of Open Access Journals (Sweden)

    S. Bettoni

    2016-03-01

    Full Text Available Minimizing the dilution of the electron beam emittance is crucial for the performance of accelerators, in particular for free electron laser facilities, where the length of the machine and the efficiency of the lasing process depend on it. Measurements performed at the SwissFEL Injector Test Facility revealed an increase in slice emittance after compressing the bunch even for moderate compression factors. The phenomenon was experimentally studied by characterizing the dependence of the effect on beam and machine parameters relevant for the bunch compression. The reproduction of these measurements in simulation required the use of a 3D beam dynamics model along the bunch compressor that includes coherent synchrotron radiation. Our investigations identified transverse effects, such as coherent synchrotron radiation and transverse space charge as the sources of the observed emittance dilution, excluding other effects, such as chromatic effects on single slices or spurious dispersion. We also present studies, both experimental and simulation based, on the effect of the optics mismatch of the slices on the variation of the slice emittance along the bunch. After a corresponding reoptimization of the beam optics in the test facility we reached slice emittances below 200 nm for the central slices along the longitudinal dimension with a moderate increase up to 300 nm in the head and tail for a compression factor of 7.5 and a bunch charge of 200 pC, equivalent to a final current of 150 A, at about 230 MeV energy.

  8. Three-dimensional CT virtual endoscopy in the detection of simulated tumors in a novel phantom bladder and ureter model.

    Science.gov (United States)

    Russell, Shane T; Kawashima, Akira; Vrtiska, Terri J; LeRoy, Andrew J; Bruesewitz, Michael R; Hartman, Robert P; Slezak, Jeffrey M; McCollough, Cynthia H; Chow, George K; King, Bernard F

    2005-03-01

    Cystoscopy and ureteroscopy have limitations in the evaluation for urothelial tumors, and both are invasive. We studied the utility of three-dimensional (3D) CT virtual endoscopy in phantom models. A phantom pelvis was constructed of Plexiglas, porcine pelvic bones, and processed animal fat and scanned at various table speeds in a four detector-row CT machine for ability to detect "tumors" of Solidwater plastic polymer. Images were reconstructed at slice thicknesses of 2.5 to 5.0 mm and reconstructed in 3D for evaluation by two radiologists with no knowledge of the scanning parameters or tumor location. Similar studies were performed with a ureter model. With 5-mm slices, the sensitivity for bladder tumors ranged from 67% for 2-mm tumors to 100% for 4-mm tumors, with 12 false-positive findings. The overall sensitivity was 86% with 3.75-mm slices with one false positive, and with 2.5-mm slices, the sensitivity was 93%, again with one false positive. For the ureteral tumors, the overall sensitivities and numbers of false positives were 88.9% and eight with 5.0-mm collimation, 88.9% and four with 3.75-mm collimation, and 100% and three with 2.5-mm collimation. The effective radiation dose for all studies was equivalent to that of a standard abdomen/pelvis scan. Although virtual endoscopy traditionally has had difficulty detecting tumors <5 mm, the multidetector-row CT protocols used in this study could detect most lesions smaller than this. The scan also depicts the other tissues of the pelvis, which is valuable for staging. The 3D images were produced using data from the CT urogram parameters standard at our institution.

  9. Offloading peak processing to virtual farm by STAR experiment at RHIC

    International Nuclear Information System (INIS)

    Balewski, Jan; Walker, Matt; Lauret, Jerome; Arkhipkin, Dmitry; Olson, Doug; Sakrejda, Iwona; Porter, Jeff; Bresnahan, John; Keahey, Kate; Stevens, Justin

    2012-01-01

    The Virtual Machine framework was used to assemble the STAR-computing environment, validated once, deployed on over 100 8-core VMs at NERSC and Argonne National Lab, and used as a homogeneous Virtual Farm processing events acquired in real time by STAR detector located at Brookhaven National Lab. To provide time dependent calibration, a database snapshot scheme was devised. The two high capacity filesystems, localized at the opposite coasts of US and interconnected via Globus-Online protocol, were used in this setup, which resulted with a highly scalable Cloud-based extension of STAR computing resources. The system was in continuous operation for over 3 months.

  10. Tumor Slice Culture: A New Avatar in Personalized Oncology

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-16-1-0149 TITLE: Tumor Slice Culture: A New Avatar in Personalized Oncology PRINCIPAL INVESTIGATOR: Raymond Yeung...CONTRACT NUMBER Tumor Slice Culture: A New Avatar in Personalized Oncology 5b. GRANT NUMBER W81XWH-16-1-0149 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...10 Annual Report 2017: Tumor Slice Culture: A new avatar for personalized oncology 1. INTRODUCTION: The goal of this research is to advance our

  11. ATLAS grid compute cluster with virtualized service nodes

    International Nuclear Information System (INIS)

    Mejia, J; Stonjek, S; Kluth, S

    2010-01-01

    The ATLAS Computing Grid consists of several hundred compute clusters distributed around the world as part of the Worldwide LHC Computing Grid (WLCG). The Grid middleware and the ATLAS software which has to be installed on each site, often require a certain Linux distribution and sometimes even specific version thereof. On the other hand, mostly due to maintenance reasons, computer centres install the same operating system and version on all computers. This might lead to problems with the Grid middleware if the local version is different from the one for which it has been developed. At RZG we partly solved this conflict by using virtualization technology for the service nodes. We will present the setup used at RZG and show how it helped to solve the problems described above. In addition we will illustrate the additional advantages gained by the above setup.

  12. Culturing of PC12 Cells, Neuronal Cells, Astrocytes Cultures and Brain Slices in an Open Microfluidic System

    DEFF Research Database (Denmark)

    Al Atraktchi, Fatima Al-Zahraa; Bakmand, Tanya; Rømer Sørensen, Ane

    The brain is the center of the nervous system, where serious neurodegenerative diseases such as Parkinson’s, Alzheimer’s and Huntington’s are products of functional loss in the neural cells (1). Typical techniques used to investigate these diseases lack precise control of the cellular surroundings......, in addition to isolating the neural tissue from nutrient delivery and to creating unwanted gradients (2). This means that typical techniques used to investigate neurodegenerative diseases cannot mimic in vivo conditions, as closely as desired. We have developed a novel microfluidic system for culturing PC12...... cells, neuronal cells, astrocytes cultures and brain slices. The microfluidic system provides efficient nutrient delivery, waste removal, access to oxygen, fine control over the neurochemical environment and access to modern microscopy. Additionally, the setup consists of an in vitro culturing...

  13. A simple method for multiday imaging of slice cultures.

    Science.gov (United States)

    Seidl, Armin H; Rubel, Edwin W

    2010-01-01

    The organotypic slice culture (Stoppini et al. A simple method for organotypic cultures of nervous tissue. 1991;37:173-182) has become the method of choice to answer a variety of questions in neuroscience. For many experiments, however, it would be beneficial to image or manipulate a slice culture repeatedly, for example, over the course of many days. We prepared organotypic slice cultures of the auditory brainstem of P3 and P4 mice and kept them in vitro for up to 4 weeks. Single cells in the auditory brainstem were transfected with plasmids expressing fluorescent proteins by way of electroporation (Haas et al. Single-cell electroporation for gene transfer in vivo. 2001;29:583-591). The culture was then placed in a chamber perfused with oxygenated ACSF and the labeled cell imaged with an inverted wide-field microscope repeatedly for multiple days, recording several time-points per day, before returning the slice to the incubator. We describe a simple method to image a slice culture preparation during the course of multiple days and over many continuous hours, without noticeable damage to the tissue or photobleaching. Our method uses a simple, inexpensive custom-built insulator constructed around the microscope to maintain controlled temperature and uses a perfusion chamber as used for in vitro slice recordings. (c) 2009 Wiley-Liss, Inc.

  14. Endogenous 24S-hydroxycholesterol modulates NMDAR-mediated function in hippocampal slices.

    Science.gov (United States)

    Sun, Min-Yu; Izumi, Yukitoshi; Benz, Ann; Zorumski, Charles F; Mennerick, Steven

    2016-03-01

    N-methyl-D-aspartate receptors (NMDARs), a major subtype of glutamate receptors mediating excitatory transmission throughout the central nervous system (CNS), play critical roles in governing brain function and cognition. Because NMDAR dysfunction contributes to the etiology of neurological and psychiatric disorders including stroke and schizophrenia, NMDAR modulators are potential drug candidates. Our group recently demonstrated that the major brain cholesterol metabolite, 24S-hydroxycholesterol (24S-HC), positively modulates NMDARs when exogenously administered. Here, we studied whether endogenous 24S-HC regulates NMDAR activity in hippocampal slices. In CYP46A1(-/-) (knockout; KO) slices where endogenous 24S-HC is greatly reduced, NMDAR tone, measured as NMDAR-to-α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor (AMPAR) excitatory postsynaptic current (EPSC) ratio, was reduced. This difference translated into more NMDAR-driven spiking in wild-type (WT) slices compared with KO slices. Application of SGE-301, a 24S-HC analog, had comparable potentiating effects on NMDAR EPSCs in both WT and KO slices, suggesting that endogenous 24S-HC does not saturate its NMDAR modulatory site in ex vivo slices. KO slices did not differ from WT slices in either spontaneous neurotransmission or in neuronal intrinsic excitability, and exhibited LTP indistinguishable from WT slices. However, KO slices exhibited higher resistance to persistent NMDAR-dependent depression of synaptic transmission induced by oxygen-glucose deprivation (OGD), an effect restored by SGE-301. Together, our results suggest that loss of positive NMDAR tone does not elicit compensatory changes in excitability or transmission, but it protects transmission against NMDAR-mediated dysfunction. We expect that manipulating this endogenous NMDAR modulator may offer new treatment strategies for neuropsychiatric dysfunction. Copyright © 2016 the American Physiological Society.

  15. Server farms with setup costs

    NARCIS (Netherlands)

    Gandhi, A.; Harchol-Balter, M.; Adan, I.J.B.F.

    2010-01-01

    In this paper we consider server farms with a setup cost. This model is common in manufacturing systems and data centers, where there is a cost to turn servers on. Setup costs always take the form of a time delay, and sometimes there is additionally a power penalty, as in the case of data centers.

  16. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  17. A Planetarium Inside Your Office: Virtual Reality in the Dome Production Pipeline

    Science.gov (United States)

    Summers, Frank

    2018-01-01

    Producing astronomy visualization sequences for a planetarium without ready access to a dome is a distorted geometric challenge. Fortunately, one can now use virtual reality (VR) to simulate a dome environment without ever leaving one's office chair. The VR dome experience has proven to be a more than suitable pre-visualization method that requires only modest amounts of processing beyond the standard production pipeline. It also provides a crucial testbed for identifying, testing, and fixing the visual constraints and artifacts that arise in a spherical presentation environment. Topics adreesed here will include rendering, geometric projection, movie encoding, software playback, and hardware setup for a virtual dome using VR headsets.

  18. Generalized Fourier slice theorem for cone-beam image reconstruction.

    Science.gov (United States)

    Zhao, Shuang-Ren; Jiang, Dazong; Yang, Kevin; Yang, Kang

    2015-01-01

    The cone-beam reconstruction theory has been proposed by Kirillov in 1961, Tuy in 1983, Feldkamp in 1984, Smith in 1985, Pierre Grangeat in 1990. The Fourier slice theorem is proposed by Bracewell 1956, which leads to the Fourier image reconstruction method for parallel-beam geometry. The Fourier slice theorem is extended to fan-beam geometry by Zhao in 1993 and 1995. By combining the above mentioned cone-beam image reconstruction theory and the above mentioned Fourier slice theory of fan-beam geometry, the Fourier slice theorem in cone-beam geometry is proposed by Zhao 1995 in short conference publication. This article offers the details of the derivation and implementation of this Fourier slice theorem for cone-beam geometry. Especially the problem of the reconstruction from Fourier domain has been overcome, which is that the value of in the origin of Fourier space is 0/0. The 0/0 type of limit is proper handled. As examples, the implementation results for the single circle and two perpendicular circle source orbits are shown. In the cone-beam reconstruction if a interpolation process is considered, the number of the calculations for the generalized Fourier slice theorem algorithm is O(N^4), which is close to the filtered back-projection method, here N is the image size of 1-dimension. However the interpolation process can be avoid, in that case the number of the calculations is O(N5).

  19. Improved biochemical preservation of lung slices during cold storage.

    Science.gov (United States)

    Bull, D A; Connors, R C; Reid, B B; Albanil, A; Stringham, J C; Karwande, S V

    2000-05-15

    Development of lung preservation solutions typically requires whole-organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that lung slices could be used to assess preservation of biochemical function during cold storage. Whole rat lungs were precision cut into slices with a thickness of 500 microm and preserved at 4 degrees C in the following solutions: University of Wisconsin (UW), Euro-Collins (EC), low-potassium-dextran (LPD), Kyoto (K), normal saline (NS), or a novel lung preservation solution (NPS) developed using this model. Lung biochemical function was assessed by ATP content (etamol ATP/mg wet wt) and capacity for protein synthesis (cpm/mg protein) immediately following slicing (0 h) and at 6, 12, 18, and 24 h of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as means +/- SD. ATP content was significantly higher in the lung slices stored in NPS compared with all other solutions at each time point (P cold storage. Copyright 2000 Academic Press.

  20. Virtual simulation of radiotherapeutic treatment of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Haest, K; Vanregemorter, J [Algemeen Ziekenhuis Middelheim, Antwerp (Belgium). Dept. of Radiotherapy; Van Dam, J [Louvain Univ. (Belgium)

    1995-12-01

    Virtual simulation allows to simulate the radiotherapeutic treatment by computer, based on a CT scan of the patient in treatment position. The routinely obtained CT scans of prostate cancer patients in treatment position were used after conventional simulation for a parallel virtual simulation. In a first step the three-dimensional electron density data of the CT were used to outline the prostate and critical organs as three-dimensional volumes of interest. Based on the 3D information of the pre-defined target volume and a pre-set 3D margin, beams and beam blocks were automatically generated according to the beam set-up. A beam`s-eye view of the volumes of interest was calculated for each beam, superimposed on a digitally reconstructed radiograph using the actual divergence of the beam. At the same time the dose distribution was computed for the fields and blocks generated by the virtual simulator. The resulting Dose Volume Histograms for prostate, rectum and bladder were reviewed and compared with the Dose Volume Histograms obtained from the conventional simulation process. During both virtual and conventional simulation, time commitments required for all the members of the radiotherapy treatment team were recorded. It is concluded that routine use of virtual simulation is possible in a busy radiation oncology department; virtual simulation results in most cases in smaller field sizes than conventional simulation; Dose Volume Histograms show that virtual simulation of the prostate minimizes the dose delivered to the bladder; a shift in workload can be expected from technicians towards physicists and medical doctors with an overall decrease in time for both personnel and patient.

  1. Virtual simulation of radiotherapeutic treatment of the prostate

    International Nuclear Information System (INIS)

    Haest, K.; Vanregemorter, J.

    1995-01-01

    Virtual simulation allows to simulate the radiotherapeutic treatment by computer, based on a CT scan of the patient in treatment position. The routinely obtained CT scans of prostate cancer patients in treatment position were used after conventional simulation for a parallel virtual simulation. In a first step the three-dimensional electron density data of the CT were used to outline the prostate and critical organs as three-dimensional volumes of interest. Based on the 3D information of the pre-defined target volume and a pre-set 3D margin, beams and beam blocks were automatically generated according to the beam set-up. A beam's-eye view of the volumes of interest was calculated for each beam, superimposed on a digitally reconstructed radiograph using the actual divergence of the beam. At the same time the dose distribution was computed for the fields and blocks generated by the virtual simulator. The resulting Dose Volume Histograms for prostate, rectum and bladder were reviewed and compared with the Dose Volume Histograms obtained from the conventional simulation process. During both virtual and conventional simulation, time commitments required for all the members of the radiotherapy treatment team were recorded. It is concluded that routine use of virtual simulation is possible in a busy radiation oncology department; virtual simulation results in most cases in smaller field sizes than conventional simulation; Dose Volume Histograms show that virtual simulation of the prostate minimizes the dose delivered to the bladder; a shift in workload can be expected from technicians towards physicists and medical doctors with an overall decrease in time for both personnel and patient

  2. Continuous Slice Functional Calculus in Quaternionic Hilbert Spaces

    Science.gov (United States)

    Ghiloni, Riccardo; Moretti, Valter; Perotti, Alessandro

    2013-04-01

    The aim of this work is to define a continuous functional calculus in quaternionic Hilbert spaces, starting from basic issues regarding the notion of spherical spectrum of a normal operator. As properties of the spherical spectrum suggest, the class of continuous functions to consider in this setting is the one of slice quaternionic functions. Slice functions generalize the concept of slice regular function, which comprises power series with quaternionic coefficients on one side and that can be seen as an effective generalization to quaternions of holomorphic functions of one complex variable. The notion of slice function allows to introduce suitable classes of real, complex and quaternionic C*-algebras and to define, on each of these C*-algebras, a functional calculus for quaternionic normal operators. In particular, we establish several versions of the spectral map theorem. Some of the results are proved also for unbounded operators. However, the mentioned continuous functional calculi are defined only for bounded normal operators. Some comments on the physical significance of our work are included.

  3. Thermoluminescence results on slices from a Hiroshima tile UHFSFT03

    International Nuclear Information System (INIS)

    Stoneham, Doreen

    1987-01-01

    As was reported at the May 1984 Utah thermoluminescence (TL) workshop, high fired tiles and porcelain fragments can be sliced into 200 μm sections with constant surface area. When conventional pre-dose measurements were carried out on these slices the doses evaluated were in good agreement with results obtained by other workers using conventional quartz separation techniques. There are several advantages in using slices. First, less sample is needed as about 50 consecutive slices can be cut from a block measuring typically 1 cm 2 cross section and 2 cm in length. There are no problems with securing grains to the plate or loss of grains during measurement. Hypothetically there is less damage to the grains when they are cut slowly under cold water than when they are crushed. The disadvantage is that other minerals besides quartz are present in the slice and the signal is weaker than that obtained using quartz inclusions

  4. Modeling and Realization of a Bearingless Flux-Switching Slice Motor

    Directory of Open Access Journals (Sweden)

    Wolfgang Gruber

    2017-03-01

    Full Text Available This work introduces a novel bearingless slice motor design: the bearingless flux-switching slice motor. In contrast to state-of-the-art bearingless slice motors, the rotor in this new design does not include any permanent rotor magnets. This offers advantages for disposable devices, such as those used in the medical industry, and extends the range of bearingless slice motors toward high-temperature applications. In this study, our focus is on the analytical modeling of the suspension force torque generation of a single coil and the bearingless motor. We assessed motor performance in relation to motor topology by applying performance factors. A prototype motor was optimized, designed, and manufactured. We also presented the state-of-the-art nonlinear feedback control scheme used. The motor was operated, and both static and dynamic measurements were taken on a test bench, thus successfully demonstrating the functionality and applicability of the novel bearingless slice motor concept.

  5. Design and Development of a tomato Slicing Machine

    OpenAIRE

    Kamaldeen Oladimeji Salaudeen; Awagu E. F.

    2012-01-01

    Principle of slicing was reviewed and tomato slicing machine was developed based on appropriate technology. Locally available materials like wood, stainless steel and mild steel were used in the fabrication. The machine was made to cut tomatoes in 2cm thickness. The capacity of the machine is 540.09g per minute and its performance efficiency is 70%.

  6. Sugar uptake and starch biosynthesis by slices of developing maize endosperm

    International Nuclear Information System (INIS)

    Felker, F.C.; Liu, Kangchien; Shannon, J.C.

    1990-01-01

    14 C-Sugar uptake and incorporation into starch by slices of developing maize (Zea mays L.) endosperm were examined and compared with sugar uptake by maize endosperm-derived suspension cultures. Rates of sucrose, fructose, and D- and L-glucose uptake by slices were similar, whereas uptake rates for these sugars differed greatly in suspension cultures. Concentration dependence of sucrose, fructose, and D-glucose uptake was biphasic (consisting of linear plus saturable components) with suspension cultures but linear with slices. These and other differences suggest that endosperm slices are freely permeable to sugars. After diffusion into the slices, sugars were metabolized and incorporated into starch. Starch synthesis, but not sugar accumulation, was greatly reduced by 2.5 millimolar p-chloromercuribenzenesulfonic acid and 0.1 millimolar carbonyl cyanide m-chlorophenylhydrazone. Starch synthesis was dependent on kernel age and incubation temperature, but not on external pH (5 through 8). Competing sugars generally did not affect the distribution of 14 C among the soluble sugars extracted from endosperm slices incubated in 14 C-sugars. Competing hexoses reduced the incorporation of 14 C into starch, but competing sucrose did not, suggesting that sucrose is not a necessary intermediate in starch biosynthesis. The bidirectional permeability of endosperm slices to sugars makes the characterization of sugar transport into endosperm slices impossible, however the model system is useful for experiments dealing with starch biosynthesis which occurs in the metabolically active tissue

  7. High-temperature metallography setup

    International Nuclear Information System (INIS)

    Blumenfeld, M.; Shmarjahu, D.; Elfassy, S.

    1979-06-01

    A high-temperature metallography setup is presented. In this setup the observation of processes such as that of copper recrystallization was made possible, and the structure of metals such as uranium could be revealed. A brief historical review of part of the research works that have been done with the help of high temperature metallographical observation technique since the beginning of this century is included. Detailed description of metallographical specimen preparation technique and theoretical criteria based on the rate of evaporation of materials present on the polished surface of the specimens are given

  8. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography

    International Nuclear Information System (INIS)

    Burgstahler, Christof; Reimann, Anja; Brodoefel, Harald; Tsiflikas, Ilias; Thomas, Christoph; Heuschmid, Martin; Daferner, Ulrike; Drosch, Tanja; Schroeder, Stephen; Herberts, Tina

    2009-01-01

    Multi-slice computed tomography (MSCT) is a non-invasive modality to visualize coronary arteries with an overall good image quality. Improved spatial and temporal resolution of 64-slice and dual-source computed tomography (DSCT) scanners are supposed to have a positive impact on diagnostic accuracy and image quality. However, quantitative parameters to compare image quality of 16-slice, 64-slice MSCT and DSCT are missing. A total of 256 CT examinations were evaluated (Siemens, Sensation 16: n=90; Siemens Sensation 64: n=91; Siemens Definition: n=75). Mean Hounsfield units (HU) were measured in the cavum of the left ventricle (LV), the ascending aorta (Ao), the left ventricular myocardium (My) and the proximal part of the left main (LM), the left anterior descending artery (LAD), the right coronary artery (RCA) and the circumflex artery (CX). Moreover, the ratio of intraluminal attenuation (HU) to myocardial attenuation was assessed for all coronary arteries. Clinical data [body mass index (BMI), gender, heart rate] were accessible for all patients. Mean attenuation (CA) of the coronary arteries was significantly higher for DSCT in comparison to 64- and 16-slice MSCT within the RCA [347±13 vs. 254±14 (64-MSCT) vs. 233±11 (16-MSCT) HU], LM (362±11/275 ± 12/262±9), LAD (332±17/248±19/219±14) and LCX (310±12/210±13/221±10, all p<0.05), whereas there was no significant difference between DSCT and 64-MSCT for the LV, the Ao and My. Heart rate had a significant impact on CA ratio in 16-slice and 64-slice CT only (p<0.05). BMI had no impact on the CA ratio in DSCT only (p<0.001). Improved spatial and temporal resolution of dual-source CT is associated with better opacification of the coronary arteries and a better contrast with the myocardium, which is independent of heart rate. In comparison to MSCT, opacification of the coronary arteries at DSCT is not affected by BMI. The main advantage of DSCT lies with the heart rate independency, which might have a

  9. A Case-Based Study with Radiologists Performing Diagnosis Tasks in Virtual Reality.

    Science.gov (United States)

    Venson, José Eduardo; Albiero Berni, Jean Carlo; Edmilson da Silva Maia, Carlos; Marques da Silva, Ana Maria; Cordeiro d'Ornellas, Marcos; Maciel, Anderson

    2017-01-01

    In radiology diagnosis, medical images are most often visualized slice by slice. At the same time, the visualization based on 3D volumetric rendering of the data is considered useful and has increased its field of application. In this work, we present a case-based study with 16 medical specialists to assess the diagnostic effectiveness of a Virtual Reality interface in fracture identification over 3D volumetric reconstructions. We developed a VR volume viewer compatible with both the Oculus Rift and handheld-based head mounted displays (HMDs). We then performed user experiments to validate the approach in a diagnosis environment. In addition, we assessed the subjects' perception of the 3D reconstruction quality, ease of interaction and ergonomics, and also the users opinion on how VR applications can be useful in healthcare. Among other results, we have found a high level of effectiveness of the VR interface in identifying superficial fractures on head CTs.

  10. A virtual radiation therapy workflow training simulation

    International Nuclear Information System (INIS)

    Bridge, P.; Crowe, S.B.; Gibson, G.; Ellemor, N.J.; Hargrave, C.; Carmichael, M.

    2016-01-01

    Aim: Simulation forms an increasingly vital component of clinical skills development in a wide range of professional disciplines. Simulation of clinical techniques and equipment is designed to better prepare students for placement by providing an opportunity to learn technical skills in a “safe” academic environment. In radiotherapy training over the last decade or so this has predominantly comprised treatment planning software and small ancillary equipment such as mould room apparatus. Recent virtual reality developments have dramatically changed this approach. Innovative new simulation applications and file processing and interrogation software have helped to fill in the gaps to provide a streamlined virtual workflow solution. This paper outlines the innovations that have enabled this, along with an evaluation of the impact on students and educators. Method: Virtual reality software and workflow applications have been developed to enable the following steps of radiation therapy to be simulated in an academic environment: CT scanning using a 3D virtual CT scanner simulation; batch CT duplication; treatment planning; 3D plan evaluation using a virtual linear accelerator; quantitative plan assessment, patient setup with lasers; and image guided radiotherapy software. Results: Evaluation of the impact of the virtual reality workflow system highlighted substantial time saving for academic staff as well as positive feedback from students relating to preparation for clinical placements. Students valued practice in the “safe” environment and the opportunity to understand the clinical workflow ahead of clinical department experience. Conclusion: Simulation of most of the radiation therapy workflow and tasks is feasible using a raft of virtual reality simulation applications and supporting software. Benefits of this approach include time-saving, embedding of a case-study based approach, increased student confidence, and optimal use of the clinical environment

  11. Improved biochemical preservation of heart slices during cold storage.

    Science.gov (United States)

    Bull, D A; Reid, B B; Connors, R C; Albanil, A; Stringham, J C; Karwande, S V

    2000-01-01

    Development of myocardial preservation solutions requires the use of whole organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that myocardial slices could be used to assess preservation of biochemical function during cold storage. Whole rat hearts were precision cut into slices with a thickness of 200 microm and preserved at 4 degrees C in one of the following solutions: Columbia University (CU), University of Wisconsin (UW), D5 0.2% normal saline with 20 meq/l KCL (QNS), normal saline (NS), or a novel cardiac preservation solution (NPS) developed using this model. Myocardial biochemical function was assessed by ATP content (etamoles ATP/mg wet weight) and capacity for protein synthesis (counts per minute (cpm)/mg protein) immediately following slicing (0 hours), and at 6, 12, 18, and 24 hours of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as the mean +/- standard deviation. ATP content was higher in the heart slices stored in the NPS compared to all other solutions at 6, 12, 18 and 24 hours of cold storage (p cold storage (p cold storage.

  12. Accuracy in tangential breast treatment set-up

    International Nuclear Information System (INIS)

    Tienhoven, G. van; Lanson, J.H.; Crabeels, D.; Heukelom, S.; Mijnheer, B.J.

    1991-01-01

    To test accuracy and reproducibility of tangential breast treatment set-up used in The Netherlands Cancer Institute, a portal imaging study was performed in 12 patients treated for early stage breast cancer. With an on-line electronic portal imaging device (EPID) images were obtained of each patient in several fractions and compared with simulator films and with each other. In 5 patients multiple images (on the average 7) per fraction were obtained to evaluate set-up variations due to respiratory movement. The central lung distance (CLD) and other set-up parameters varied within 1 fraction about 1mm (1SD). The average variation of these parameters between various fractions was about 2 mm (1SD). The differences between simulator and treatment set-up over all patients and all fractions was on the average 2-3mm for the central beam edge to skin distance and CLD. It can be concluded that the tangential breast treatment set-up is very stable and reproducible and that respiration does not have a significant influence on treatment volume. EPID appears to be an adequate tool for studies of treatment set-up accuracy like this. (author). 35 refs.; 2 figs.; 3 tabs

  13. A setup for active fault diagnosis

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik

    2006-01-01

    A setup for active fault diagnosis (AFD) of parametric faults in dynamic systems is formulated in this paper. It is shown that it is possible to use the same setup for both open loop systems, closed loop systems based on a nominal feedback controller as well as for closed loop systems based...... on a reconfigured feedback controller. This will make the proposed AFD approach very useful in connection with fault tolerant control (FTC). The setup will make it possible to let the fault diagnosis part of the fault tolerant controller remain unchanged after a change in the feedback controller. The setup for AFD...... is based on the YJBK (after Youla, Jabr, Bongiorno and Kucera) parameterization of all stabilizing feedback controllers and the dual YJBK parameterization. It is shown that the AFD is based directly on the dual YJBK transfer function matrix. This matrix will be named the fault signature matrix when...

  14. High precision neutron interferometer setup S18b

    International Nuclear Information System (INIS)

    Hasegawa, Y.; Lemmel, H.

    2011-01-01

    The present setup at S18 is a multi purpose instrument. It is used for both interferometry and a Bonse-Hart camera for USANS (Ultra Small Angle Neutron Scattering) spectroscopy with wide range tunability of wavelength. Some recent measurements demand higher stability of the instrument, which made us to propose a new setup dedicated particularly for neutron interferometer experiments requiring high phase stability. To keep both options available, we suggest building the new setup in addition to the old one. By extending the space of the present setup by 1.5 m to the upstream, both setups can be accommodated side by side. (authors)

  15. Comparing virtual with physical wedge for the transmission factors

    International Nuclear Information System (INIS)

    Lin Kuei-Hua; Lin Jao-Perng; Chu Tieh-Chi; Liu Mu-Tai

    2000-01-01

    This paper investigates the discrepancies between virtual wedge and physical wedge at the standard wedge angles of 15, 30, 45, and 60 degrees. The dose distributions for virtual wedge and physics wedge were measured by using a commercial multichamber detector array. The transmission factors of each virtual wedge and physical wedge were measured for Siemens PRIMUS 3008 linear accelerator by single ion chamber. These factors were used to set-up the clinical treatment data tables for clinical dosimetry for virtual wedge utilization. The Wellhoefer IC15, 0.13cc chamber was installed on the chamber frame of Wellhoefer water phantom (48x48x40 cm 3 ). The surface of water was at 100 cm SSD. The output factor in water were measured on the central axis of each field at 5 cm depth for 6MV or 10 cm depth for 15MV X-ray on virtual wedge and physical wedge. Comparing virtual wedge with physical wedge for transmission factor as field size range from 4x4 to 25x25 cm 2 . We have measured the dose distributions using the chamber array for 25x25 cm 2 virtual wedge fields and physical wedge fields at wedge angles of 15deg to 60deg. The dose profiles at various depths were also measured using the chamber array. The transmission factors of each physical wedge were slowly increased as field sizes increase, and had different value for each wedge angle. The transmission factors of each virtual wedge were almost constant value as 1.0 for each wedge angle. The results show that the dose profiles including the penumbra dose measured by the chamber array for virtual wedge agree with those measured for the physical wedge. For transmission factors of virtual wedge were constant value as 1.0 for each angles, namely output without wedge is almost equal to output with wedge on the central axis. Virtual wedge has practical and dosimetric advantages over physical wedge. (author)

  16. Virtual Exercise Training Software System

    Science.gov (United States)

    Vu, L.; Kim, H.; Benson, E.; Amonette, W. E.; Barrera, J.; Perera, J.; Rajulu, S.; Hanson, A.

    2018-01-01

    The purpose of this study was to develop and evaluate a virtual exercise training software system (VETSS) capable of providing real-time instruction and exercise feedback during exploration missions. A resistive exercise instructional system was developed using a Microsoft Kinect depth-camera device, which provides markerless 3-D whole-body motion capture at a small form factor and minimal setup effort. It was hypothesized that subjects using the newly developed instructional software tool would perform the deadlift exercise with more optimal kinematics and consistent technique than those without the instructional software. Following a comprehensive evaluation in the laboratory, the system was deployed for testing and refinement in the NASA Extreme Environment Mission Operations (NEEMO) analog.

  17. Pyrethroid insecticides evoke neurotransmitter release from rabbit striatal slices

    International Nuclear Information System (INIS)

    Eells, J.T.; Dubocovich, M.L.

    1988-01-01

    The effects of the synthetic pyrethroid insecticide fenvalerate ([R,S]-alpha-cyano-3-phenoxybenzyl[R,S]-2-(4-chlorophenyl)-3- methylbutyrate) on neurotransmitter release in rabbit brain slices were investigated. Fenvalerate evoked a calcium-dependent release of [ 3 H]dopamine and [ 3 H]acetylcholine from rabbit striatal slices that was concentration-dependent and specific for the toxic stereoisomer of the insecticide. The release of [ 3 H]dopamine and [ 3 H]acetylcholine by fenvalerate was modulated by D2 dopamine receptor activation and antagonized completely by the sodium channel blocker, tetrodotoxin. These findings are consistent with an action of fenvalerate on the voltage-dependent sodium channels of the presynaptic membrane resulting in membrane depolarization, and the release of dopamine and acetylcholine by a calcium-dependent exocytotic process. In contrast to results obtained in striatal slices, fenvalerate did not elicit the release of [ 3 H]norepinephrine or [ 3 H]acetylcholine from rabbit hippocampal slices indicative of regional differences in sensitivity to type II pyrethroid actions

  18. A novel Brain Computer Interface for classification of social joint attention in autism and comparison of 3 experimental setups: A feasibility study.

    Science.gov (United States)

    Amaral, Carlos P; Simões, Marco A; Mouga, Susana; Andrade, João; Castelo-Branco, Miguel

    2017-10-01

    We present a novel virtual-reality P300-based Brain Computer Interface (BCI) paradigm using social cues to direct the focus of attention. We combined interactive immersive virtual-reality (VR) technology with the properties of P300 signals in a training tool which can be used in social attention disorders such as autism spectrum disorder (ASD). We tested the novel social attention training paradigm (P300-based BCI paradigm for rehabilitation of joint-attention skills) in 13 healthy participants, in 3 EEG systems. The more suitable setup was tested online with 4 ASD subjects. Statistical accuracy was assessed based on the detection of P300, using spatial filtering and a Naïve-Bayes classifier. We compared: 1 - g.Mobilab+ (active dry-electrodes, wireless transmission); 2 - g.Nautilus (active electrodes, wireless transmission); 3 - V-Amp with actiCAP Xpress dry-electrodes. Significant statistical classification was achieved in all systems. g.Nautilus proved to be the best performing system in terms of accuracy in the detection of P300, preparation time, speed and reported comfort. Proof of concept tests in ASD participants proved that this setup is feasible for training joint attention skills in ASD. This work provides a unique combination of 'easy-to-use' BCI systems with new technologies such as VR to train joint-attention skills in autism. Our P300 BCI paradigm is feasible for future Phase I/II clinical trials to train joint-attention skills, with successful classification within few trials, online in ASD participants. The g.Nautilus system is the best performing one to use with the developed BCI setup. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Digital setup for Doppler broadening spectroscopy

    International Nuclear Information System (INIS)

    Cizek, J; Vlcek, M; Prochazka, I

    2011-01-01

    New digital spectrometer for measurement of the Doppler shift of annihilation photons was developed and tested in this work. Digital spectrometer uses a fast 12-bit digitizer for direct sampling of signals from HPGe detectors. Analysis of sampled waveforms is performed off-line in software. Performance of the new digital setup was compared with its traditional analogue counterpart. Superior energy resolution was achieved in the digital setup. Moreover, the digital setup allows for a better control of the shape of detector signals. This enables to eliminate undesired signals damaged by pile-up effects or by ballistic deficit.

  20. Detection of patient setup errors with a portal image - DRR registration software application.

    Science.gov (United States)

    Sutherland, Kenneth; Ishikawa, Masayori; Bengua, Gerard; Ito, Yoichi M; Miyamoto, Yoshiko; Shirato, Hiroki

    2011-02-18

    The purpose of this study was to evaluate a custom portal image - digitally reconstructed radiograph (DRR) registration software application. The software works by transforming the portal image into the coordinate space of the DRR image using three control points placed on each image by the user, and displaying the fused image. In order to test statistically that the software actually improves setup error estimation, an intra- and interobserver phantom study was performed. Portal images of anthropomorphic thoracic and pelvis phantoms with virtually placed irradiation fields at known setup errors were prepared. A group of five doctors was first asked to estimate the setup errors by examining the portal and DRR image side-by-side, not using the software. A second group of four technicians then estimated the same set of images using the registration software. These two groups of human subjects were then compared with an auto-registration feature of the software, which is based on the mutual information between the portal and DRR images. For the thoracic case, the average distance between the actual setup error and the estimated error was 4.3 ± 3.0 mm for doctors using the side-by-side method, 2.1 ± 2.4 mm for technicians using the registration method, and 0.8 ± 0.4mm for the automatic algorithm. For the pelvis case, the average distance between the actual setup error and estimated error was 2.0 ± 0.5 mm for the doctors using the side-by-side method, 2.5 ± 0.4 mm for technicians using the registration method, and 2.0 ± 1.0 mm for the automatic algorithm. The ability of humans to estimate offset values improved statistically using our software for the chest phantom that we tested. Setup error estimation was further improved using our automatic error estimation algorithm. Estimations were not statistically different for the pelvis case. Consistency improved using the software for both the chest and pelvis phantoms. We also tested the automatic algorithm with a

  1. Virtual environment to evaluate multimodal feedback strategies for augmented navigation of the visually impaired.

    Science.gov (United States)

    Hara, Masayuki; Shokur, Solaiman; Yamamoto, Akio; Higuchi, Toshiro; Gassert, Roger; Bleuler, Hannes

    2010-01-01

    This paper proposes a novel experimental environment to evaluate multimodal feedback strategies for augmented navigation of the visually impaired. The environment consists of virtual obstacles and walls, an optical tracking system and a simple device with audio and vibrotactile feedback that interacts with the virtual environment, and presents many advantages in terms of safety, flexibility, control over experimental parameters and cost. The subject can freely move in an empty room, while the position of head and arm are tracked in real time. A virtual environment (walls, obstacles) is randomly generated, and audio and vibrotactile feedback are given according to the distance from the subjects arm to the virtual walls/objects. We investigate the applicability of our environment using a simple, commercially available feedback device. Experiments with unimpaired subjects show that it is possible to use the setup to "blindly" navigate in an unpredictable virtual environment. This validates the environment as a test platform to investigate navigation and exploration strategies of the visually impaired, and to evaluate novel technologies for augmented navigation.

  2. AR Feels "Softer" than VR: Haptic Perception of Stiffness in Augmented versus Virtual Reality.

    Science.gov (United States)

    Gaffary, Yoren; Le Gouis, Benoit; Marchal, Maud; Argelaguet, Ferran; Arnaldi, Bruno; Lecuyer, Anatole

    2017-11-01

    Does it feel the same when you touch an object in Augmented Reality (AR) or in Virtual Reality (VR)? In this paper we study and compare the haptic perception of stiffness of a virtual object in two situations: (1) a purely virtual environment versus (2) a real and augmented environment. We have designed an experimental setup based on a Microsoft HoloLens and a haptic force-feedback device, enabling to press a virtual piston, and compare its stiffness successively in either Augmented Reality (the virtual piston is surrounded by several real objects all located inside a cardboard box) or in Virtual Reality (the same virtual piston is displayed in a fully virtual scene composed of the same other objects). We have conducted a psychophysical experiment with 12 participants. Our results show a surprising bias in perception between the two conditions. The virtual piston is on average perceived stiffer in the VR condition compared to the AR condition. For instance, when the piston had the same stiffness in AR and VR, participants would select the VR piston as the stiffer one in 60% of cases. This suggests a psychological effect as if objects in AR would feel "softer" than in pure VR. Taken together, our results open new perspectives on perception in AR versus VR, and pave the way to future studies aiming at characterizing potential perceptual biases.

  3. Influence of random setup error on dose distribution

    International Nuclear Information System (INIS)

    Zhai Zhenyu

    2008-01-01

    Objective: To investigate the influence of random setup error on dose distribution in radiotherapy and determine the margin from ITV to PTV. Methods: A random sample approach was used to simulate the fields position in target coordinate system. Cumulative effect of random setup error was the sum of dose distributions of all individual treatment fractions. Study of 100 cumulative effects might get shift sizes of 90% dose point position. Margins from ITV to PTV caused by random setup error were chosen by 95% probability. Spearman's correlation was used to analyze the influence of each factor. Results: The average shift sizes of 90% dose point position was 0.62, 1.84, 3.13, 4.78, 6.34 and 8.03 mm if random setup error was 1,2,3,4,5 and 6 mm,respectively. Univariate analysis showed the size of margin was associated only by the size of random setup error. Conclusions: Margin of ITV to PTV is 1.2 times random setup error for head-and-neck cancer and 1.5 times for thoracic and abdominal cancer. Field size, energy and target depth, unlike random setup error, have no relation with the size of the margin. (authors)

  4. Inventory control with multiple setup costs

    NARCIS (Netherlands)

    Alp, O.; Huh, W.T.; Tan, T.

    2014-01-01

    We consider an infinite-horizon, periodic-review, single-item production/inventory system with random demand and backordering, where multiple setups are allowed in any period and a separate fixed cost is associated for each setup. Contrary to the majority of the literature on this topic, we do not

  5. Verification-Driven Slicing of UML/OCL Models

    DEFF Research Database (Denmark)

    Shaikh, Asadullah; Clarisó Viladrosa, Robert; Wiil, Uffe Kock

    2010-01-01

    computational complexity can limit their scalability. In this paper, we consider a specific static model (UML class diagrams annotated with unrestricted OCL constraints) and a specific property to verify (satisfiability, i.e., “is it possible to create objects without violating any constraint?”). Current...... approaches to this problem have an exponential worst-case runtime. We propose a technique to improve their scalability by partitioning the original model into submodels (slices) which can be verified independently and where irrelevant information has been abstracted. The definition of the slicing procedure...

  6. Mapping, Awareness, and Virtualization Network Administrator Training Tool (MAVNATT) Architecture and Framework

    Science.gov (United States)

    2015-06-01

    unit may setup and teardown the entire tactical infrastructure multiple times per day. This tactical network administrator training is a critical...language and runs on Linux and Unix based systems. All provisioning is based around the Nagios Core application, a powerful backend solution for network...start up a large number of virtual machines quickly. CORE supports the simulation of fixed and mobile networks. CORE is open-source, written in Python

  7. Virtual commissioning of automated micro-optical assembly

    Science.gov (United States)

    Schlette, Christian; Losch, Daniel; Haag, Sebastian; Zontar, Daniel; Roßmann, Jürgen; Brecher, Christian

    2015-02-01

    In this contribution, we present a novel approach to enable virtual commissioning for process developers in micro-optical assembly. Our approach aims at supporting micro-optics experts to effectively develop assisted or fully automated assembly solutions without detailed prior experience in programming while at the same time enabling them to easily implement their own libraries of expert schemes and algorithms for handling optical components. Virtual commissioning is enabled by a 3D simulation and visualization system in which the functionalities and properties of automated systems are modeled, simulated and controlled based on multi-agent systems. For process development, our approach supports event-, state- and time-based visual programming techniques for the agents and allows for their kinematic motion simulation in combination with looped-in simulation results for the optical components. First results have been achieved for simply switching the agents to command the real hardware setup after successful process implementation and validation in the virtual environment. We evaluated and adapted our system to meet the requirements set by industrial partners-- laser manufacturers as well as hardware suppliers of assembly platforms. The concept is applied to the automated assembly of optical components for optically pumped semiconductor lasers and positioning of optical components for beam-shaping

  8. Slice through an LHC bending magnet

    CERN Multimedia

    Slice through an LHC superconducting dipole (bending) magnet. The slice includes a cut through the magnet wiring (niobium titanium), the beampipe and the steel magnet yokes. Particle beams in the Large Hadron Collider (LHC) have the same energy as a high-speed train, squeezed ready for collision into a space narrower than a human hair. Huge forces are needed to control them. Dipole magnets (2 poles) are used to bend the paths of the protons around the 27 km ring. Quadrupole magnets (4 poles) focus the proton beams and squeeze them so that more particles collide when the beams’ paths cross. There are 1232 15m long dipole magnets in the LHC.

  9. Preparation of positional renal slices for study of cell-specific toxicity.

    Science.gov (United States)

    Ruegg, C E; Gandolfi, A J; Nagle, R B; Krumdieck, C L; Brendel, K

    1987-04-01

    To reduce structural complexity, rabbit kidneys were sliced perpendicular to their cortical-papillary axis to isolate four distinct cell groupings. This positional orientation allows identification of each renal cell type based on its location within the slice. A mechanical slicer was used to make several precision-cut slices rapidly from an oriented cylindrical core of renal tissue, with minimal tissue trauma. Slices were then submerged under a gently circulating oxygenated media in a fritted glass support system that maintains viability (intracellular K+/DNA ratio) and structural integrity (histology) for at least 30 h. A high dose of mercuric chloride (10(-3) M) was used to demonstrate the structural and biochemical changes of intoxicated slices. This method provides a controlled subchronic in vitro system for the study of the individual cell types involved in cell-specific renal toxicities and may also be a useful tool for addressing other pharmacological and physiological research questions.

  10. Creation of individual ideally shaped stents using multi-slice CT: in vitro results from the semi-automatic virtual stent (SAVS) designer

    International Nuclear Information System (INIS)

    Hyodoh, Hideki; Katagiri, Yoshimi; Hyodoh, Kazusa; Akiba, Hidenari; Hareyama, Masato; Sakai, Toyohiko

    2005-01-01

    To plan stent-grafting for thoracic aortic aneurysm with complicated morphology, we created a virtual stent-grafting program [Semi Automatic Virtual Stent (SAVS) designer] using three-dimensional CT data. The usefulness of the SAVS designer was evaluated by measurement of transformed anatomical and straight stents. Curved model images (source, multi-planer reconstruction and volume rendering) were created, and a hollow virtual stent was produced by the SAVS designer. A straight Nitinol stent was transformed to match the curved configuration of the virtual stent. The accuracy of the anatomical stent was evaluated by experimental strain phantom studies in comparison with the straight stent. Mean separation length was 0 mm in the anatomical stent [22 mm outer diameter (OD)] and 5 mm in the straight stent (22 mm OD). The straight stent strain voltage was four times that of the anatomical stent at the stent end. The anatomical stent is useful because it fits the curved structure of the aorta and reduces the strain force compared to the straight stent. The SAVS designer can help to design and produce the anatomical stent. (orig.)

  11. VERSE - Virtual Equivalent Real-time Simulation

    Science.gov (United States)

    Zheng, Yang; Martin, Bryan J.; Villaume, Nathaniel

    2005-01-01

    Distributed real-time simulations provide important timing validation and hardware in the- loop results for the spacecraft flight software development cycle. Occasionally, the need for higher fidelity modeling and more comprehensive debugging capabilities - combined with a limited amount of computational resources - calls for a non real-time simulation environment that mimics the real-time environment. By creating a non real-time environment that accommodates simulations and flight software designed for a multi-CPU real-time system, we can save development time, cut mission costs, and reduce the likelihood of errors. This paper presents such a solution: Virtual Equivalent Real-time Simulation Environment (VERSE). VERSE turns the real-time operating system RTAI (Real-time Application Interface) into an event driven simulator that runs in virtual real time. Designed to keep the original RTAI architecture as intact as possible, and therefore inheriting RTAI's many capabilities, VERSE was implemented with remarkably little change to the RTAI source code. This small footprint together with use of the same API allows users to easily run the same application in both real-time and virtual time environments. VERSE has been used to build a workstation testbed for NASA's Space Interferometry Mission (SIM PlanetQuest) instrument flight software. With its flexible simulation controls and inexpensive setup and replication costs, VERSE will become an invaluable tool in future mission development.

  12. Split scheduling with uniform setup times.

    NARCIS (Netherlands)

    F. Schalekamp; R.A. Sitters (René); S.L. van der Ster; L. Stougie (Leen); V. Verdugo; A. van Zuylen

    2015-01-01

    htmlabstractWe study a scheduling problem in which jobs may be split into parts, where the parts of a split job may be processed simultaneously on more than one machine. Each part of a job requires a setup time, however, on the machine where the job part is processed. During setup, a

  13. A novel lung slice system with compromised antioxidant defenses

    Energy Technology Data Exchange (ETDEWEB)

    Hardwick, S.J.; Adam, A.; Cohen, G.M. (Univ. of London (England)); Smith, L.L. (Imperial Chemical Industries PLC, Cheshire (England))

    1990-04-01

    In order to facilitate the study of oxidative stress in lung tissue, rat lung slices with impaired antioxidant defenses were prepared and used. Incubation of lung slices with the antineoplastic agent 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) (100 {mu}M) in an amino acid-rich medium for 45 min produced a near-maximal (approximately 85%), irreversible inhibition of glutathione reductase, accompanied by only a modest (approximately 15%) decrease in pulmonary nonprotein sulfhydryls (NPSH) and no alteration in intracellular ATP, NADP{sup +}, and NADPH levels. The amounts of NADP(H), ATP, and NPSH were stable over a 4-hr incubation period following the removal from BCNU. The viability of the system was further evaluated by measuring the rate of evolution of {sup 14}CO{sub 2} from D-({sup 14}C(U))-glucose. The rates of evolution were almost identical in the compromised system when compared with control slices over a 4-hr time period. By using slices with compromised oxidative defenses, preliminary results have been obtained with paraquat, nitrofurantoin, and 2,3-dimethoxy-1,4-naphthoquinone.

  14. A novel lung slice system with compromised antioxidant defenses

    International Nuclear Information System (INIS)

    Hardwick, S.J.; Adam, A.; Cohen, G.M.; Smith, L.L.

    1990-01-01

    In order to facilitate the study of oxidative stress in lung tissue, rat lung slices with impaired antioxidant defenses were prepared and used. Incubation of lung slices with the antineoplastic agent 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) (100 μM) in an amino acid-rich medium for 45 min produced a near-maximal (approximately 85%), irreversible inhibition of glutathione reductase, accompanied by only a modest (approximately 15%) decrease in pulmonary nonprotein sulfhydryls (NPSH) and no alteration in intracellular ATP, NADP + , and NADPH levels. The amounts of NADP(H), ATP, and NPSH were stable over a 4-hr incubation period following the removal from BCNU. The viability of the system was further evaluated by measuring the rate of evolution of 14 CO 2 from D-[ 14 C(U)]-glucose. The rates of evolution were almost identical in the compromised system when compared with control slices over a 4-hr time period. By using slices with compromised oxidative defenses, preliminary results have been obtained with paraquat, nitrofurantoin, and 2,3-dimethoxy-1,4-naphthoquinone

  15. Short Term Motor-Skill Acquisition Improves with Size of Self-Controlled Virtual Hands.

    Science.gov (United States)

    Ossmy, Ori; Mukamel, Roy

    2017-01-01

    Visual feedback in general, and from the body in particular, is known to influence the performance of motor skills in humans. However, it is unclear how the acquisition of motor skills depends on specific visual feedback parameters such as the size of performing effector. Here, 21 healthy subjects physically trained to perform sequences of finger movements with their right hand. Through the use of 3D Virtual Reality devices, visual feedback during training consisted of virtual hands presented on the screen, tracking subject's hand movements in real time. Importantly, the setup allowed us to manipulate the size of the displayed virtual hands across experimental conditions. We found that performance gains increase with the size of virtual hands. In contrast, when subjects trained by mere observation (i.e., in the absence of physical movement), manipulating the size of the virtual hand did not significantly affect subsequent performance gains. These results demonstrate that when it comes to short-term motor skill learning, the size of visual feedback matters. Furthermore, these results suggest that highest performance gains in individual subjects are achieved when the size of the virtual hand matches their real hand size. These results may have implications for optimizing motor training schemes.

  16. Short Term Motor-Skill Acquisition Improves with Size of Self-Controlled Virtual Hands.

    Directory of Open Access Journals (Sweden)

    Ori Ossmy

    Full Text Available Visual feedback in general, and from the body in particular, is known to influence the performance of motor skills in humans. However, it is unclear how the acquisition of motor skills depends on specific visual feedback parameters such as the size of performing effector. Here, 21 healthy subjects physically trained to perform sequences of finger movements with their right hand. Through the use of 3D Virtual Reality devices, visual feedback during training consisted of virtual hands presented on the screen, tracking subject's hand movements in real time. Importantly, the setup allowed us to manipulate the size of the displayed virtual hands across experimental conditions. We found that performance gains increase with the size of virtual hands. In contrast, when subjects trained by mere observation (i.e., in the absence of physical movement, manipulating the size of the virtual hand did not significantly affect subsequent performance gains. These results demonstrate that when it comes to short-term motor skill learning, the size of visual feedback matters. Furthermore, these results suggest that highest performance gains in individual subjects are achieved when the size of the virtual hand matches their real hand size. These results may have implications for optimizing motor training schemes.

  17. Split Scheduling with Uniform Setup Times

    NARCIS (Netherlands)

    Schalekamp, F.; Sitters, R.A.; van der Ster, S.L.; Stougie, L.; Verdugo, V.; van Zuylen, A.

    2015-01-01

    We study a scheduling problem in which jobs may be split into parts, where the parts of a split job may be processed simultaneously on more than one machine. Each part of a job requires a setup time, however, on the machine where the job part is processed. During setup, a machine cannot process or

  18. Virtual embryology: a 3D library reconstructed from human embryo sections and animation of development process.

    Science.gov (United States)

    Komori, M; Miura, T; Shiota, K; Minato, K; Takahashi, T

    1995-01-01

    The volumetric shape of a human embryo and its development is hard to comprehend as they have been viewed as a 2D schemes in a textbook or microscopic sectional image. In this paper, a CAI and research support system for human embryology using multimedia presentation techniques is described. In this system, 3D data is acquired from a series of sliced specimens. Its 3D structure can be viewed interactively by rotating, extracting, and truncating its whole body or organ. Moreover, the development process of embryos can be animated using a morphing technique applied to the specimen in several stages. The system is intended to be used interactively, like a virtual reality system. Hence, the system is called Virtual Embryology.

  19. Equilibrium initial data for moving puncture simulations: the stationary 1 + log slicing

    International Nuclear Information System (INIS)

    Baumgarte, T W; Matera, K; Etienne, Z B; Liu, Y T; Shapiro, S L; Taniguchi, K; Murchadha, N O

    2009-01-01

    We discuss a 'stationary 1 + log' slicing condition for the construction of solutions to Einstein's constraint equations. For stationary spacetimes, these initial data give a stationary foliation when evolved with 'moving puncture' gauge conditions that are often used in black hole evolutions. The resulting slicing is time independent and agrees with the slicing generated by being dragged along a timelike Killing vector of the spacetime. When these initial data are evolved with moving puncture gauge conditions, numerical errors arising from coordinate evolution should be minimized. While these properties appear very promising, suggesting that this slicing condition should be an attractive alternative to, for example, maximal slicing, we demonstrate in this paper that solutions can be constructed only for a small class of problems. For binary black hole initial data, in particular, it is often assumed that there exists an approximate helical Killing vector that generates the binary's orbit. We show that 1 + log slices that are stationary with respect to such a helical Killing vector cannot be asymptotically flat, unless the spacetime possesses an additional axial Killing vector.

  20. Electron slicing for the generation of tunable femtosecond soft x-ray pulses from a free electron laser and slice diagnostics

    Directory of Open Access Journals (Sweden)

    S. Di Mitri

    2013-04-01

    Full Text Available We present the experimental results of femtosecond slicing an ultrarelativistic, high brightness electron beam with a collimator. In contrast to some qualitative considerations reported in Phys. Rev. Lett. 92, 074801 (2004PRLTAO0031-900710.1103/PhysRevLett.92.074801, we first demonstrate that the collimation process preserves the slice beam quality, in agreement with our theoretical expectations, and that the collimation is compatible with the operation of a linear accelerator in terms of beam transport, radiation dose, and collimator heating. Accordingly, the collimated beam can be used for the generation of stable femtosecond soft x-ray pulses of tunable duration, from either a self-amplified spontaneous emission or an externally seeded free electron laser. The proposed method also turns out to be a more compact and cheaper solution for electron slice diagnostics than the commonly used radio frequency deflecting cavities and has minimal impact on the machine design.

  1. Psychological and physiological human responses to simulated and real environments: A comparison between Photographs, 360° Panoramas, and Virtual Reality.

    Science.gov (United States)

    Higuera-Trujillo, Juan Luis; López-Tarruella Maldonado, Juan; Llinares Millán, Carmen

    2017-11-01

    Psychological research into human factors frequently uses simulations to study the relationship between human behaviour and the environment. Their validity depends on their similarity with the physical environments. This paper aims to validate three environmental-simulation display formats: photographs, 360° panoramas, and virtual reality. To do this we compared the psychological and physiological responses evoked by simulated environments set-ups to those from a physical environment setup; we also assessed the users' sense of presence. Analysis show that 360° panoramas offer the closest to reality results according to the participants' psychological responses, and virtual reality according to the physiological responses. Correlations between the feeling of presence and physiological and other psychological responses were also observed. These results may be of interest to researchers using environmental-simulation technologies currently available in order to replicate the experience of physical environments. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. (Non)perturbative gravity, nonlocality, and nice slices

    International Nuclear Information System (INIS)

    Giddings, Steven B.

    2006-01-01

    Perturbative dynamics of gravity is investigated for high-energy scattering and in black hole backgrounds. In the latter case, a straightforward perturbative analysis fails, in a close parallel to the failure of the former when the impact parameter reaches the Schwarzschild radius. This suggests a flaw in a semiclassical description of physics on spatial slices that intersect both outgoing Hawking radiation and matter that has carried information into a black hole; such slices are instrumental in a general argument for black hole information loss. This indicates a possible role for the proposal that nonperturbative gravitational physics is intrinsically nonlocal

  3. The clinical efficacy of 1 mm-slice CT of the middle ear

    International Nuclear Information System (INIS)

    Noda, Kazuhiro; Noiri, Teruhisa; Doi, Katsumi; Koizuka, Izumi; Tanaka, Hisashi; Mishiro, Yasuo; Okumura, Shin-ichi; Kubo, Takeshi

    2000-01-01

    The efficacy of the preoperative 1 mm-slice CT for evaluating the condition of the ossicular chain and the facial canal was assessed. CT findings were compared with the operative findings of middle ears in 120 cases of chronic otitis media or cholesteatoma that underwent tympanoplasty. The reliability of 1 mm-slice CT in detecting any defect of the ossicular chain was much superior to those of 2 mm-slice CT previously reported, and the difference between them is essential for preoperative information. On the other hand, thinner slice than 1 mm may be unnecessary, especially in routine use. (author)

  4. The clinical efficacy of 1 mm-slice CT of the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Noda, Kazuhiro; Noiri, Teruhisa [Kawanishi Municipal Hospital, Hyogo (Japan); Doi, Katsumi; Koizuka, Izumi; Tanaka, Hisashi; Mishiro, Yasuo; Okumura, Shin-ichi; Kubo, Takeshi

    2000-02-01

    The efficacy of the preoperative 1 mm-slice CT for evaluating the condition of the ossicular chain and the facial canal was assessed. CT findings were compared with the operative findings of middle ears in 120 cases of chronic otitis media or cholesteatoma that underwent tympanoplasty. The reliability of 1 mm-slice CT in detecting any defect of the ossicular chain was much superior to those of 2 mm-slice CT previously reported, and the difference between them is essential for preoperative information. On the other hand, thinner slice than 1 mm may be unnecessary, especially in routine use. (author)

  5. Slice through an LHC focusing magnet

    CERN Multimedia

    Slice through an LHC superconducting quadrupole (focusing) magnet. The slice includes a cut through the magnet wiring (niobium titanium), the beampipe and the steel magnet yokes. Particle beams in the Large Hadron Collider (LHC) have the same energy as a high-speed train, squeezed ready for collision into a space narrower than a human hair. Huge forces are needed to control them. Dipole magnets (2 poles) are used to bend the paths of the protons around the 27 km ring. Quadrupole magnets (4 poles) focus the proton beams and squeeze them so that more particles collide when the beams’ paths cross. Bringing beams into collision requires a precision comparable to making two knitting needles collide, launched from either side of the Atlantic Ocean.

  6. Feasibility study of 2D thick-slice MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Ishimori, Yoshiyuki; Takeuchi, Miho; Higashimura, Kyouji; Komuro, Hiroyuki

    2000-01-01

    Conditions required to perform contrast MR digital subtraction angiography using a two-dimensional thick-slice high-speed gradient echo were investigated. The conditions in the phantom experiment included: slice profile, flip angle, imaging matrix, fat suppression, duration of IR pulse and frequency selectivity, flip angle of IR pulse and inversion time. Based on the results of the experiment, 2D thick-slice MRDSA was performed in volunteers. Under TR/TE=5.3-9/1.3-1.8 ms conditions, the requirements were a slice thick enough to include the target region, a flip angle of 10 degrees, and a phase matrix of 96 or more. Fat suppression was required for adipose-tissue-rich regions, such as the abdomen. The optimal conditions for applying the IR preparation pulse of the IR prepped fast gradient recalled echo as spectrally selective inversion recovery appeared to be: duration of IR pulse =20 ms, flip angle =100 degrees, and inversion time =40 ms. The authors concluded that it was feasible to perform 2D thick-slice MRDSA with time resolution within 1 second. (K.H.)

  7. Free-breathing cardiac MR stress perfusion with real-time slice tracking.

    Science.gov (United States)

    Basha, Tamer A; Roujol, Sébastien; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Manning, Warren J; Nezafat, Reza

    2014-09-01

    To develop a free-breathing cardiac MR perfusion sequence with slice tracking for use after physical exercise. We propose to use a leading navigator, placed immediately before each 2D slice acquisition, for tracking the respiratory motion and updating the slice location in real-time. The proposed sequence was used to acquire CMR perfusion datasets in 12 healthy adult subjects and 8 patients. Images were compared with the conventional perfusion (i.e., without slice tracking) results from the same subjects. The location and geometry of the myocardium were quantitatively analyzed, and the perfusion signal curves were calculated from both sequences to show the efficacy of the proposed sequence. The proposed sequence was significantly better compared with the conventional perfusion sequence in terms of qualitative image scores. Changes in the myocardial location and geometry decreased by 50% in the slice tracking sequence. Furthermore, the proposed sequence had signal curves that are smoother and less noisy. The proposed sequence significantly reduces the effect of the respiratory motion on the image acquisition in both rest and stress perfusion scans. Copyright © 2013 Wiley Periodicals, Inc.

  8. A simple experimental setup for magneto-dielectric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Manimuthu, P.; Shanker, N. Praveen; Kumar, K. Saravana; Venkateswaran, C., E-mail: cvunom@hotmail.com

    2014-09-01

    The increasing demand for the multiferroic materials calls for the need of an experimental setup that will facilitate magneto-dielectric coupling measurements. A connector setup designed makes it possible to measure and analyze the dielectric properties of the material under the influence of a magnetic field. The salient feature of this setup is in its incorporation with the already existing experimental facilities.

  9. A simple experimental setup for magneto-dielectric measurements

    International Nuclear Information System (INIS)

    Manimuthu, P.; Shanker, N. Praveen; Kumar, K. Saravana; Venkateswaran, C.

    2014-01-01

    The increasing demand for the multiferroic materials calls for the need of an experimental setup that will facilitate magneto-dielectric coupling measurements. A connector setup designed makes it possible to measure and analyze the dielectric properties of the material under the influence of a magnetic field. The salient feature of this setup is in its incorporation with the already existing experimental facilities

  10. Implementation of virtual simulation with a wide-bore multislice helcalct scanner

    International Nuclear Information System (INIS)

    Greer, P.; Kenny, J.

    2004-01-01

    Full text: Multislice large-bore CT scanners specifically designed for radiotherapy have very recently become available. The issues relating to these type of scanners in radiotherapy and the implementation of virtual simulation are therefore of much current interest. A GE LightSpeed RT 4-slice helical CT scanner with a 80 cm bore size was installed in the radiation oncology department of the Newcastle Mater Hospital. This replaced our only simulator, a conventional unit. Specific issues relating to the imaging performance, and virtual simulation process with the large-bore multislice scanner were studied to ensure an accurate radiotherapy process. The detector array fully samples a 50 cm diameter scan circle. The reconstructed diameter can be increased to 65 cm with partial sampling of the extra volume. The GE Advantage Sim (ASim) virtual simulation software was commissioned, with transfer of CT images and DICOM RT plans to the Pinnacle radiotherapy planning system (RTPS) for dose calculation. Some specific issues investigated were: 1) The image quality performance for image reconstruction with the 65 cm area compared to 50 cm was measured with a line-pair phantom. 2) The accuracy of CT numbers with lateral position was assessed with a commercial electron density phantom. 3) Couch lateral movement and sag during acquisition were measured with the couch weighted with 86 kg. 4) The accuracy of the transfer of plans from ASim to Pinnacle was verified with known plan geometries. Image resolution throughout the entire CT image was found to be significantly lower when scan reconstruction was performed with 65 cm scan circle compared to 50 cm. The 0.3, 0.38 and 0.5 1p/mm bars were clearly distinguishable with the 50 cm reconstruction compared to only the 0.3 1p/mm bars in the 65 cm reconstruction. 2) CT numbers varied significantly outside the 50 cm reconstructed area. 3) Couch lateral movement during scanning was within 1 mm. Couch sag was 4 mm at the imaging plane

  11. Development of real-time motion capture system for 3D on-line games linked with virtual character

    Science.gov (United States)

    Kim, Jong Hyeong; Ryu, Young Kee; Cho, Hyung Suck

    2004-10-01

    Motion tracking method is being issued as essential part of the entertainment, medical, sports, education and industry with the development of 3-D virtual reality. Virtual human character in the digital animation and game application has been controlled by interfacing devices; mouse, joysticks, midi-slider, and so on. Those devices could not enable virtual human character to move smoothly and naturally. Furthermore, high-end human motion capture systems in commercial market are expensive and complicated. In this paper, we proposed a practical and fast motion capturing system consisting of optic sensors, and linked the data with 3-D game character with real time. The prototype experiment setup is successfully applied to a boxing game which requires very fast movement of human character.

  12. Study of Energy Consumption of Potato Slices During Drying Process

    Directory of Open Access Journals (Sweden)

    Hafezi Negar

    2015-06-01

    Full Text Available One of the new methods of food drying using infrared heating under vacuum is to increase the drying rate and maintain the quality of dried product. In this study, potato slices were dried using vacuum-infrared drying. Experiments were performed with the infrared lamp power levels 100, 150 and 200 W, absolute pressure levels 20, 80, 140 and 760 mmHg, and with three thicknesses of slices 1, 2 and 3 mm, in three repetitions. The results showed that the infrared lamp power, absolute pressure and slice thickness have important effects on the drying of potato. With increasing the radiation power, reducing the absolute pressure (acts of vacuum in the dryer chamber and also reducing the thickness of potato slices, drying time and the amount of energy consumed is reduced. In relation to thermal utilization efficiency, results indicated that with increasing the infrared radiation power and decreasing the absolute pressure, thermal efficiency increased.

  13. Excitatory and inhibitory pathways modulate kainate excitotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Casaccia-Bonnefil, P; Benedikz, Eirikur; Rai, R

    1993-01-01

    In organotypic hippocampal slice cultures, kainate (KA) specifically induces cell loss in the CA3 region while N-methyl-D-aspartate induces cell loss in the CA1 region. The sensitivity of slice cultures to KA toxicity appears only after 2 weeks in vitro which parallels the appearance of mossy...... fibers. KA toxicity is potentiated by co-application with the GABA-A antagonist, picrotoxin. These data suggest that the excitotoxicity of KA in slice cultures is modulated by both excitatory and inhibitory synapses....

  14. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  15. Left atrial passive emptying function is preserved in patients with permanent atrial fibrillation--a 320-slice multidetector computed tomography study

    DEFF Research Database (Denmark)

    Agner, Bue Fridolin Ross; Kühl, Jørgen Tobias; Kofoed, Klaus Fuglsang

    2014-01-01

    OBJECTIVE: Left atrial (LA) mechanical function is thought to be virtually inexistent in patients with permanent atrial fibrillation (AF). Due to recent advances in multidetector computed tomography (MDCT) technology, it is now possible to acquire images of the entire heart in a single heartbeat....... The objective of this study was to compare individual components of LA function assessed by MDCT in patients with permanent AF and patients in sinus rhythm (SR). METHODS: 320-slice MDCT was performed in 30 patients with permanent AF. Measurements of LA volumes during the cardiac cycle were compared to 30......; 71 vs. 30 ml/m(2), p permanent AF have significantly increased LA volumes throughout the cardiac...

  16. The visibility of mandibular canal on orthoradial and oblique CBCT slices at molar implant sites

    International Nuclear Information System (INIS)

    Alkhader, Mustafa; Jarab, Fadi; Shaweesh, Ashraf; Hudieb, Malik

    2016-01-01

    The aim of the present study was to compare visibility of the mandibular canal on cone beam computed tomography (CBCT)-based orthoradial and oblique slices at molar implant sites. CBCT images for 132 mandibular molar implant sites were selected for the study. After generating orthoradial and oblique slices, two observers evaluated the visibility of the mandibular canal using three-point scoring scale (1-3, good to excellent). Wilcoxon signed-rank test compared the visibility scores of the two slices. Both orthoradial and oblique slices obtained from CBCT had only very good to excellent mandibular canal visibility scores. At 114 mandibular molar implant sites, the visibility score was equal on both orthoradial and oblique slices. Although the visibility score was higher on orthoradial slices for 12 implant sites, the visibility score was higher for six implant sites on oblique slices and the difference was not significant. Therefore, the visibility of the mandibular canal was excellent and comparable on most of orthoradial and oblique slices obtained from CBCT images

  17. Magnetohydrodynamics of unsteady viscous fluid on boundary layer past a sliced sphere

    Science.gov (United States)

    Nursalim, Rahmat; Widodo, Basuki; Imron, Chairul

    2017-10-01

    Magnetohydrodynamics (MHD) is important study in engineering and industrial fields. By study on MHD, we can reach the fluid flow characteristics that can be used to minimize its negative effect to an object. In decades, MHD has been widely studied in various geometry forms and fluid types. The sliced sphere is a geometry form that has not been investigated. In this paper we study magnetohydrodynamics of unsteady viscous fluid on boundary layer past a sliced sphere. Assumed that the fluid is incompressible, there is no magnetic field, there is no electrical voltage, the sliced sphere is fix and there is no barrier around the object. In this paper we focus on velocity profile at stagnation point (x = 0°). Mathematical model is governed by continuity and momentum equation. It is converted to non-dimensional, stream function, and similarity equation. Solution of the mathematical model is obtained by using Keller-Box numerical method. By giving various of slicing angle and various of magnetic parameter we get the simulation results. The simulation results show that increasing the slicing angle causes the velocity profile be steeper. Also, increasing the value of magnetic parameter causes the velocity profile be steeper. On the large slicing angle there is no significant effect of magnetic parameter to velocity profile, and on the high the value of magnetic parameter there is no significant effect of slicing angle to velocity profile.

  18. Minimization of number of setups for mounting machines

    Energy Technology Data Exchange (ETDEWEB)

    Kolman, Pavel; Nchor, Dennis; Hampel, David [Department of Statistics and Operation Analysis, Faculty of Business and Economics, Mendel University in Brno, Zemědělská 1, 603 00 Brno (Czech Republic); Žák, Jaroslav [Institute of Technology and Business, Okružní 517/10, 370 01 České Budejovice (Czech Republic)

    2015-03-10

    The article deals with the problem of minimizing the number of setups for mounting SMT machines. SMT is a device used to assemble components on printed circuit boards (PCB) during the manufacturing of electronics. Each type of PCB has a different set of components, which are obligatory. Components are placed in the SMT tray. The problem consists in the fact that the total number of components used for all products is greater than the size of the tray. Therefore, every change of manufactured product requires a complete change of components in the tray (i.e., a setup change). Currently, the number of setups corresponds to the number of printed circuit board type. Any production change affects the change of setup and stops production on one shift. Many components occur in more products therefore the question arose as to how to deploy the products into groups so as to minimize the number of setups. This would result in a huge increase in efficiency of production.

  19. Setup uncertainties: consequences for multi-isocentre stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Ebert, M.A.; Harper, C.S.

    2000-01-01

    Full text: Beam data for use in dose calculations by planning systems is generally measured under static and controlled conditions. Yet, patient motion and setup uncertainties will effectively blur the resulting dose distributions leading to a discrepancy between planned and delivered dose distributions. This is particularly so for stereotactic radiotherapy where small well-defined fields are used. When multiple isocentres are used (possibly for larger irregular lesions), relative motion of isocentres due to setup variations may have deleterious effects on the intended radiation delivery. The influence of setup uncertainties was examined by performing a three-dimensional convolution of measured off-axis ratio (OAR) data with a Maxwellian distribution, with standard deviations representing several feasible levels of inaccuracy in patient setup. A sample of patient plans (predominantly multi-isocentre plans) were then considered using original (measured) OAR data, and then modified data in order to observe the resulting effect. The effect of systematic localisation error was also considered by examining resulting DVHs as isocentres were shifted by fixed amounts. In all cases considered, the maximum dose varied quite minimally with increase in setup error with the variation decreasing with increasing high-dose volume. The minimum dose however varied more significantly, and this has serious consequences for dose prescription as the minimum dose can be the controlling factor in treatment efficacy. For multi-isocentre plans, the degree of non-uniformity generated by setup error was not as significant as originally expected. This is in part due to the non-uniformity already present in such plans to begin with. Through incorporation of the effect of setup error into planning data, the influence of setup variations on dose distributions for multi-isocentre treatments has been determined. This influence should be considered when creating plans based on the level of spatial

  20. On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT

    International Nuclear Information System (INIS)

    Flohr, T.; Ohnesorge, B.; Stierstorfer, K.

    2005-01-01

    The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging [de

  1. [Standardization of production of process Notopterygii Rhizoma et Radix slices].

    Science.gov (United States)

    Sun, Zhen-Yang; Wang, Ying-Zi; Nie, Rui-Jie; Zhang, Jing-Zhen; Wang, Si-Yu

    2017-12-01

    Notopterol, isoimperatorin, volatile oil and extract (water and ethanol) were used as the research objects in this study to investigate the effects of different softening method, slice thickness and drying methods on the quality of Notopterygii Rhizoma et Radix slices, and the experimental data were analyzed by homogeneous distance evaluation method. The results showed that different softening, cutting and drying processes could affect the content of five components in Notopterygii Rhizoma et Radix incisum. The best processing technology of Notopterygii Rhizoma et Radix slices was as follows: non-medicinal parts were removed; mildewed and rot as well as moth-eaten parts were removed; washed by the flowing drinking water; stacked in the drug pool; moistening method was used for softening, where 1/8 volume of water was sprayed for every 1 kg of herbs every 2 h; upper part of herbs covered with clean and moist cotton, and cut into thick slices (2-4 mm) after 12 h moistening until appropriate softness, then received blast drying for 4 h at 50 ℃, and turned over for 2 times during the drying. The process is practical and provides the experimental basis for the standardization of the processing of Notopterygii Rhizoma et Radix, with great significance to improve the quality of Notopterygii Rhizoma et Radix slices. Copyright© by the Chinese Pharmaceutical Association.

  2. Slice image pretreatment for cone-beam computed tomography based on adaptive filter

    International Nuclear Information System (INIS)

    Huang Kuidong; Zhang Dinghua; Jin Yanfang

    2009-01-01

    According to the noise properties and the serial slice image characteristics in Cone-Beam Computed Tomography (CBCT) system, a slice image pretreatment for CBCT based on adaptive filter was proposed. The judging criterion for the noise is established firstly. All pixels are classified into two classes: adaptive center weighted modified trimmed mean (ACWMTM) filter is used for the pixels corrupted by Gauss noise and adaptive median (AM) filter is used for the pixels corrupted by impulse noise. In ACWMTM filtering algorithm, the estimated Gauss noise standard deviation in the current slice image with offset window is replaced by the estimated standard deviation in the adjacent slice image to the current with the corresponding window, so the filtering accuracy of the serial images is improved. The pretreatment experiment on CBCT slice images of wax model of hollow turbine blade shows that the method makes a good performance both on eliminating noises and on protecting details. (authors)

  3. Field Observation of Setup

    National Research Council Canada - National Science Library

    Yemm, Sean

    2004-01-01

    Setup is defined as the superelevation of mean water surface within the surfzone and is caused by the reduction in wave momentum shoreward of the breaking point and compensating positive pressure gradient...

  4. Drying characteristics of pumpkin ( Cucurbita moschata) slices in convective and freeze dryer

    Science.gov (United States)

    Caliskan, Gulsah; Dirim, Safiye Nur

    2017-06-01

    This study was intended to determine the drying and rehydration kinetics of convective and freeze dried pumpkin slices (0.5 × 3.5 × 0.5 cm). A pilot scale tray drier (at 80 ± 2 °C inlet temperature, 1 m s-1 air velocity) and freeze drier (13.33 kPa absolute pressure, condenser temperature of -48 ± 2 °C) were used for the drying experiments. Drying curves were fitted to six well-known thin layer drying models. Nonlinear regression analysis was used to evaluate the parameters of the selected models by using statistical software SPSS 16.0 (SPSS Inc., USA). For the convective and freeze drying processes of pumpkin slices, the highest R2 values, and the lowest RMSE as well as χ2 values were obtained from Page model. The effective moisture diffusivity (Deff) of the convective and freeze dried pumpkin slices were obtained from the Fick's diffusion model, and they were found to be 2.233 × 10-7 and 3.040 × 10-9 m2s-1, respectively. Specific moisture extraction rate, moisture extraction rate, and specific energy consumption values were almost twice in freeze drying process. Depending on the results, moisture contents and water activity values of pumpkin slices were in acceptable limits for safe storage of products. The rehydration behaviour of [at 18 ± 2 and 100 ± 2 °C for 1:25, 1:50, 1:75, 1:100, and 1:125 solid:liquid ratios (w:w)] dried pumpkin slices was determined by Peleg's model with the highest R2. The highest total soluble solid loss of pumpkin slices was observed for the rehydration experiment which performed at 1:25 solid: liquid ratio (w:w). Rehydration ratio of freeze dried slices was found 2-3 times higher than convective dried slices.

  5. A shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy

    Science.gov (United States)

    Mitra, Jhimli; Srikantha, Abhilash; Sidibé, Désiré; Martí, Robert; Oliver, Arnau; Lladó, Xavier; Ghose, Soumya; Vilanova, Joan C.; Comet, Josep; Meriaudeau, Fabrice

    2012-02-01

    This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to perform an analysis based on shape and information theory to reach close enough to the actual MR slice as validated by experts. The Bhattacharyya distance is used to find point correspondences between shape-context representations of the prostate contours. Thereafter, Chi-square distance is used to find out those MR slices where the prostates closely match with that of the TRUS slice. Normalized Mutual Information (NMI) values of the TRUS slice with each of the axial MR slices are computed after rigid alignment and consecutively a strategic elimination based on a set of rules between the Chi-square distances and the NMI leads to the required MR slice. We validated our method for TRUS axial slices of 15 patients, of which 11 results matched at least one experts validation and the remaining 4 are at most one slice away from the expert validations.

  6. A Remote and Virtual Synchrotron Beamline

    Science.gov (United States)

    Jackson, J. M.; Alp, E.; Sturhahn, W.

    2012-12-01

    National facilities offer one-of-a-kind opportunities to apply state-of-the-art experimental techniques to the pressing scientific problems of today. Yet, few students are able to experience research projects at national facilities due to limited accessibility caused in part by limited involvement in the local academic institution, constrained working areas at the experimental stations, and/or travel costs. We present a virtual and remote beam-line for Earth science studies using nuclear resonant and inelastic x-ray scattering methods at Sector 3 of the Advanced Photon Source at Argonne National Laboratory. Off-site students have the capability of controlling their measurements via secure internet connections and webcams. Students can access a 'view only mode' for ease of interaction and safety-control. More experienced users have exclusive control of the experiment and can remotely change variables within the experimental setup. Students may also access the virtual aspects these experiments by simulating certain conditions with our newly developed software. We evaluate such a tool by giving "before" and "after" assignments to students at different levels. These levels include high-school students from the Pasadena and greater Los Angeles area school districts, undergraduate students from Caltech's SURF/MURF program, and graduate students at Caltech. We specifically target underrepresented groups. Our results thus far show that the capabilities offered by our remote and virtual beamline show improved knowledge and understanding of applying experimental-based studies at the synchrotron to solve problems in the Earth sciences.

  7. A comparative risk assessment for Listeria monocytogenes in prepackaged versus retail-sliced deli meat.

    Science.gov (United States)

    Endrikat, Sarah; Gallagher, Daniel; Pouillot, Régis; Hicks Quesenberry, Heather; Labarre, David; Schroeder, Carl M; Kause, Janell

    2010-04-01

    Deli meat was ranked as the highest-risk ready-to-eat food vehicle of Listeria monocytogenes within the 2003 U.S. Food and Drug Administration and U.S. Department of Agriculture, Food Safety and Inspection Service risk assessment. The comparative risk of L. monocytogenes in retail-sliced versus prepackaged deli meats was evaluated with a modified version of this model. Other research has found that retail-sliced deli meats have both higher prevalence and levels of L. monocytogenes than have product sliced and packaged at the manufacturer level. The updated risk assessment model considered slicing location as well as the use of growth inhibitors. The per annum comparative risk ratio for the number of deaths from retail-sliced versus prepackaged deli meats was found to be 4.89, and the per-serving comparative risk ratio was 4.27. There was a significant interaction between the use of growth inhibitors and slicing location. Almost 70% of the estimated deaths occurred from retail-sliced product that did not possess a growth inhibitor. A sensitivity analysis, assessing the effect of the model's consumer storage time and shelf life assumptions, found that even if retail-sliced deli meats were stored for a quarter of the time prepackaged deli meats were stored, retail-sliced product is 1.7 times more likely to result in death from listeriosis. Sensitivity analysis also showed that the shelf life assumption had little effect on the comparative risk ratio.

  8. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  9. Fluidic system for long-term in vitro culturing and monitoring of organotypic brain slices

    DEFF Research Database (Denmark)

    Bakmand, Tanya; Troels-Smith, Ane R.; Dimaki, Maria

    2015-01-01

    Brain slice preparations cultured in vitro have long been used as a simplified model for studying brain development, electrophysiology, neurodegeneration and neuroprotection. In this paper an open fluidic system developed for improved long term culturing of organotypic brain slices is presented....... The positive effect of continuous flow of growth medium, and thus stability of the glucose concentration and waste removal, is simulated and compared to the effect of stagnant medium that is most often used in tissue culturing. Furthermore, placement of the tissue slices in the developed device was studied...... by numerical simulations in order to optimize the nutrient distribution. The device was tested by culturing transverse hippocampal slices from 7 days old NMRI mice for a duration of 14 days. The slices were inspected visually and the slices cultured in the fluidic system appeared to have preserved...

  10. Dosimetric variation due to CT inter-slice spacing in four-dimensional carbon beam lung therapy

    International Nuclear Information System (INIS)

    Kumagai, Motoki; Mori, Shinichiro; Kandatsu, Susumu; Baba, Masayuki; Sharp, Gregory C; Asakura, Hiroshi; Endo, Masahiro

    2009-01-01

    When CT data with thick slice thickness are used in treatment planning, geometrical uncertainty may induce dosimetric errors. We evaluated carbon ion dose variations due to different CT slice thicknesses using a four-dimensional (4D) carbon ion beam dose calculation, and compared results between ungated and gated respiratory strategies. Seven lung patients were scanned in 4D mode with a 0.5 mm slice thickness using a 256-multi-slice CT scanner. CT images were averaged with various numbers of images to simulate reconstructed images with various slice thicknesses (0.5-5.0 mm). Two scenarios were studied (respiratory-ungated and -gated strategies). Range compensators were designed for each of the CT volumes with coarse inter-slice spacing to cover the internal target volume (ITV), as defined from 4DCT. Carbon ion dose distribution was computed for each resulting ITV on the 0.5 mm slice 4DCT data. The accumulated dose distribution was then calculated using deformable registration for 4D dose assessment. The magnitude of over- and under-dosage was found to be larger with the use of range compensators designed with a coarser inter-slice spacing than those obtained with a 0.5 mm slice thickness. Although no under-dosage was observed within the clinical target volume (CTV) region, D95 remained at over 97% of the prescribed dose for the ungated strategy and 95% for the gated strategy for all slice thicknesses. An inter-slice spacing of less than 3 mm may be able to minimize dose variation between the ungated and gated strategies. Although volumes with increased inter-slice spacing may reduce geometrical accuracy at a certain respiratory phase, this does not significantly affect delivery of the accumulated dose to the target during the treatment course.

  11. Brain slice on a chip: opportunities and challenges of applying microfluidic technology to intact tissues.

    Science.gov (United States)

    Huang, Yu; Williams, Justin C; Johnson, Stephen M

    2012-06-21

    Isolated brain tissue, especially brain slices, are valuable experimental tools for studying neuronal function at the network, cellular, synaptic, and single channel levels. Neuroscientists have refined the methods for preserving brain slice viability and function and converged on principles that strongly resemble the approach taken by engineers in developing microfluidic devices. With respect to brain slices, microfluidic technology may 1) overcome the traditional limitations of conventional interface and submerged slice chambers and improve oxygen/nutrient penetration into slices, 2) provide better spatiotemporal control over solution flow/drug delivery to specific slice regions, and 3) permit successful integration with modern optical and electrophysiological techniques. In this review, we highlight the unique advantages of microfluidic devices for in vitro brain slice research, describe recent advances in the integration of microfluidic devices with optical and electrophysiological instrumentation, and discuss clinical applications of microfluidic technology as applied to brain slices and other non-neuronal tissues. We hope that this review will serve as an interdisciplinary guide for both neuroscientists studying brain tissue in vitro and engineers as they further develop microfluidic chamber technology for neuroscience research.

  12. BioImg.org: A Catalog of Virtual Machine Images for the Life Sciences.

    Science.gov (United States)

    Dahlö, Martin; Haziza, Frédéric; Kallio, Aleksi; Korpelainen, Eija; Bongcam-Rudloff, Erik; Spjuth, Ola

    2015-01-01

    Virtualization is becoming increasingly important in bioscience, enabling assembly and provisioning of complete computer setups, including operating system, data, software, and services packaged as virtual machine images (VMIs). We present an open catalog of VMIs for the life sciences, where scientists can share information about images and optionally upload them to a server equipped with a large file system and fast Internet connection. Other scientists can then search for and download images that can be run on the local computer or in a cloud computing environment, providing easy access to bioinformatics environments. We also describe applications where VMIs aid life science research, including distributing tools and data, supporting reproducible analysis, and facilitating education. BioImg.org is freely available at: https://bioimg.org.

  13. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  14. Extension of shelf-life of Chickoo slices using hurdle technology

    International Nuclear Information System (INIS)

    Shirodkar, S.; Behere, A.G.; Padwal-Desai, S.R.; Lele, S.S.; Pai, J.S.

    2001-01-01

    An attempt has been made to evolve a protocol to prepare shelf-stable high moisture chickoo slices using Hurdle Technology. The process is based on a slight reduction of water activity (0.98?0.94) by osmosis with a 70 deg Brix sucrose syrup, lowering of pH (5.75 to 4.46) by addition of citric acid, addition of KMS and then subjecting the resulting slices to different doses of gamma radiation ranging from 0.25-1 kGy. Radiation processed chickoo slices remained acceptable for 8 weeks at sub-room temperature (10 ± 2 degC) and for 3 weeks at ambient temperature (28 ± 2 degC) when evaluated by a taste-test panel. (author)

  15. Exploiting the ALICE HLT for PROOF by scheduling of Virtual Machines

    International Nuclear Information System (INIS)

    Meoni, Marco; Boettger, Stefan; Zelnicek, Pierre; Kebschull, Udo; Lindenstruth, Volker

    2011-01-01

    The HLT (High-Level Trigger) group of the ALICE experiment at the LHC has prepared a virtual Parallel ROOT Facility (PROOF) enabled cluster (HAF - HLT Analysis Facility) for fast physics analysis, detector calibration and reconstruction of data samples. The HLT-Cluster currently consists of 2860 CPU cores and 175TB of storage. Its purpose is the online filtering of the relevant part of data produced by the particle detector. However, data taking is not running continuously and exploiting unused cluster resources for other applications is highly desirable and improves the usage-cost ratio of the HLT cluster. As such, unused computing resources are dedicated to a PROOF-enabled virtual cluster available to the entire collaboration. This setup is especially aimed at the prototyping phase of analyses that need a high number of development iterations and a short response time, e.g. tuning of analysis cuts, calibration and alignment. HAF machines are enabled and disabled upon user request to start or complete analysis tasks. This is achieved by a virtual machine scheduling framework which dynamically assigns and migrates virtual machines running PROOF workers to unused physical resources. Using this approach we extend the HLT usage scheme to running both online and offline computing, thereby optimizing the resource usage.

  16. Thin-Slice Perception Develops Slowly

    Science.gov (United States)

    Balas, Benjamin; Kanwisher, Nancy; Saxe, Rebecca

    2012-01-01

    Body language and facial gesture provide sufficient visual information to support high-level social inferences from "thin slices" of behavior. Given short movies of nonverbal behavior, adults make reliable judgments in a large number of tasks. Here we find that the high precision of adults' nonverbal social perception depends on the slow…

  17. A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    Science.gov (United States)

    Ertan, Koray; Taraghinia, Soheil; Sadeghi, Alireza; Atalar, Ergin

    2018-07-01

    Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. Two different field design methods are formulated to solve for the required current values of the gradient array elements for the given slice locations. The method requirements are specified, optimization problems are formulated for the minimum current norm and an analytical solution is provided. A 9-channel z-gradient coil array driven by independent, custom-designed gradient amplifiers is used to validate the theory. Performance measures such as normalized slice thickness error, gradient strength per unit norm current, power dissipation, and maximum amplitude of the magnetic field are provided for various slice locations and numbers of slices. Two and 3 slices are excited by a single-band RF pulse in simulations and phantom experiments. The possibility of multi-slice excitation with a single-band RF pulse using a z-gradient array is validated in simulations and phantom experiments. Magn Reson Med 80:400-412, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. A rapid and simple method for cryopreservation of human liver slices

    NARCIS (Netherlands)

    de Kanter, R; Olinga, Peter; Hof, I.H; de Jager, M.H; Verwillegen, W.A; Slooff, M.JH; Meijer, D.K F; Groothuis, Geny; Koster, H

    1. Precision-cut liver slices represent a suitable and convenient in vitro preparation for studying metabolism and toxicity mechanisms of drugs and toxic chemicals. Particularly in the case of human liver slices, cryopreservation would enable more efficient utilization of this scarce and irregularly

  19. Contralateral breast dose reduction using a virtual wedge

    International Nuclear Information System (INIS)

    Yeo, In Hwan; Kim, Dae Yong; Kim, Tae Hyun; Shin, Kyung Hwan; Chie, Eui Kyu; Park, Won; Lim, Do Hoon; Huh, Seung Jae; Ahn, Yong Chan

    2005-01-01

    To evaluate the contralateral breast dose using a virtual wedge compared with that using a physical wedge and an open beam in a Siemens linear accelerator. The contralateral breast dose was measured using diodes placed on a humanoid phantom. Diodes were placed at 5.5 cm (position 1), 9.5 cm (position 2), and 14 cm (position 3) along the medial-lateral line from the medial edge of the treatment field. A 6-MV photon beam was used with tangential irradiation technique at 50 and 230 degrees of gantry angle. Asymmetrically collimated 17 x 10 cm field was used. For the first set of experiment, four treatment set-ups were used, which were an open medial beam with a 30-degree wedged lateral beam (physical and virtual wedges, respectively) and a 15-degree wedge medial beam with a 15-degree wedged lateral beam (physical and virtual wedges, respectively). The second set of experiment consists of setting with medial beam without wedge, a 15-degree wedge, and a 60-degree wedge (physical and virtual wedges, respectively). Identical monitor units were delivered. Each set of experiment was repeated for three times. In the first set of experiment, the contralateral breast dose was the highest at the position 1 and decreased in order of the position 2 and 3. The contralateral breast dose was reduced with open beam on the medial side (2.70± 1.46%) compared to medial beam with a wedge (both physical and virtual) (3.25 ± 1.59%). The differences were larger with a physical wedge (0.99 ± 0.18%) than a virtual wedge (0.10 ± 0.01%) at all positions. The use of a virtual wedge reduced the contralateral breast dose by 0.12% to 1.20% of the prescribed dose compared to a physical wedge with same technique. In the second experiment, the contralateral breast dose decreased in order of the open beam, the virtual wedge, and the physical wedge at the position 1, and it decreased in order of a physical wedge, an open beam, and a virtual wedge at the position 2 and 3. The virtual wedge equipped

  20. Organotypic hippocampal slice cultures for studies of brain damage, neuroprotection and neurorepair

    DEFF Research Database (Denmark)

    Noraberg, Jens; Poulsen, Frantz Rom; Blaabjerg, Morten

    2005-01-01

    Slices of developing brain tissue can be grown for several weeks as so-called organotypic slice cultures. Here we summarize and review studies using hippocampal slice cultures to investigate mechanisms and treatment strategies for the neurodegenerative disorders like stroke (cerebral ischemia......), Alzheimer's disease (AD) and epilepsia. Studies of non-excitotoxic neurotoxic compounds and the experimental use of slice cultures in studies of HIV neurotoxicity, traumatic brain injury (TBI) and neurogenesis are included. For cerebral ischemia, experimental models with oxygen-glucose deprivation (OGD......) and exposure to glutamate receptor agonists (excitotoxins) are reviewed. For epilepsia, focus is on induction of seizures with effects on neuronal loss, axonal sprouting and neurogenesis. For Alzheimer's disease, the review centers on the use of beta-amyloid (Abeta) in different models, while the section...

  1. SU-E-J-24: Can Fiducial Marker-Based Setup Using ExacTrac Be An Alternative to Soft Tissue-Based Setup Using Cone-Beam CT for Prostate IMRT?

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, S [Department of Radiation Oncology, Niigata University Medical and Dental Hospital (Japan); Utsunomiya, S; Abe, E; Aoyama, H [Department of Radiology, Niigata University Graduate School of Medical and Dental Sciences (Japan); Satou, H [Department of Radiation Oncology, Niigata Cancer Center Hospital (Japan); Sakai, H; Yamada, T [Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital (Japan)

    2015-06-15

    Purpose: To assess an accuracy of fiducial maker-based setup using ExacTrac (ExT-based setup) as compared with soft tissue-based setup using Cone-beam CT (CBCT-based setup) for patients with prostate cancer receiving intensity-modulated radiation therapy (IMRT) for the purpose of investigating whether ExT-based setup can be an alternative to CBCT-based setup. Methods: The setup accuracy was analyzed prospectively for 7 prostate cancer patients with implanted three fiducial markers received IMRT. All patients were treated after CBCT-based setup was performed and corresponding shifts were recorded. ExacTrac images were obtained before and after CBCT-based setup. The fiducial marker-based shifts were calculated based on those two images and recorded on the assumption that the setup correction was carried out by fiducial marker-based auto correction. Mean and standard deviation of absolute differences and the correlation between CBCT and ExT shifts were estimated. Results: A total of 178 image dataset were analyzed. On the differences between CBCT and ExT shifts, 133 (75%) of 178 image dataset resulted in smaller differences than 3 mm in all dimensions. Mean differences in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) dimensions were 1.8 ± 1.9 mm, 0.7 ± 1.9 mm, and 0.6 ± 0.8 mm, respectively. The percentages of shift agreements within ±3 mm were 76% for AP, 90% for SI, and 100% for LR. The Pearson coefficient of correlation for CBCT and ExT shifts were 0.80 for AP, 0.80 for SI, and 0.65 for LR. Conclusion: This work showed that the accuracy of ExT-based setup was correlated with that of CBCT-based setup, implying that ExT-based setup has a potential ability to be an alternative to CBCT-based setup. The further work is to specify the conditions that ExT-based setup can provide the accuracy comparable to CBCT-based setup.

  2. An 8-channel transceiver 7-channel receive RF coil setup for high SNR ultrahigh-field MRI of the shoulder at 7T.

    Science.gov (United States)

    Rietsch, Stefan H G; Pfaffenrot, Viktor; Bitz, Andreas K; Orzada, Stephan; Brunheim, Sascha; Lazik-Palm, Andrea; Theysohn, Jens M; Ladd, Mark E; Quick, Harald H; Kraff, Oliver

    2017-12-01

    In this work, we present an 8-channel transceiver (Tx/Rx) 7-channel receive (Rx) radiofrequency (RF) coil setup for 7 T ultrahigh-field MR imaging of the shoulder. A C-shaped 8-channel Tx/Rx coil was combined with an anatomically close-fitting 7-channel Rx-only coil. The safety and performance parameters of this coil setup were evaluated on the bench and in phantom experiments. The 7 T MR imaging performance of the shoulder RF coil setup was evaluated in in vivo measurements using a 3D DESS, a 2D PD-weighted TSE sequence, and safety supervision based on virtual observation points. Distinct SNR gain and acceleration capabilities provided by the additional 7-channel Rx-only coil were demonstrated in phantom and in vivo measurements. The power efficiency indicated good performance of each channel and a maximum B 1 + of 19 μT if the hardware RF power limits of the MR system were exploited. MR imaging of the shoulder was demonstrated with clinically excellent image quality and submillimeter spatial resolution. The presented 8-channel transceiver 7-channel receive RF coil setup was successfully applied for in vivo 7 T MRI of the shoulder providing a clear SNR gain vs the transceiver array without the additional receive array. Homogeneous images across the shoulder region were obtained using 8-channel subject-specific phase-only RF shimming. © 2017 American Association of Physicists in Medicine.

  3. Collider shot setup for Run 2 observations and suggestions

    International Nuclear Information System (INIS)

    Annala, J.; Joshel, B.

    1996-01-01

    This note is intended to provoke discussion on Collider Run II shot setup. We hope this is a start of activities that will converge on a functional description of what is needed for shot setups in Collider Run II. We will draw on observations of the present shot setup to raise questions and make suggestions for the next Collider run. It is assumed that the reader has some familiarity with the Collider operational issues. Shot setup is defined to be the time between the end of a store and the time the Main Control Room declares colliding beams. This is the time between Tevatron clock events SCE and SCB. This definition does not consider the time experiments use to turn on their detectors. This analysis was suggested by David Finley. The operational scenarios for Run II will require higher levels of reliability and speed for shot setup. See Appendix I and II. For example, we estimate that a loss of 3 pb -1 /week (with 8 hour stores) will occur if shot setups take 90 minutes instead of 30 minutes. In other words: If you do 12 shots for one week and accept an added delay of one minute in each shot, you will loose more than 60 nb -1 for that week alone (based on a normal shot setup of 30 minutes). These demands should lead us to be much more pedantic about all the factors that affect shot setups. Shot setup will be viewed as a distinct process that is composed of several inter- dependent 'components': procedures, hardware, controls, and sociology. These components don't directly align with the different Accelerator Division departments, but are topical groupings of the needed accelerator functions. Defining these components, and categorizing our suggestions within them, are part of the goal of this document. Of course, some suggestions span several of these components

  4. Adaptive SLICE method: an enhanced method to determine nonlinear dynamic respiratory system mechanics

    International Nuclear Information System (INIS)

    Zhao, Zhanqi; Möller, Knut; Guttmann, Josef

    2012-01-01

    The objective of this paper is to introduce and evaluate the adaptive SLICE method (ASM) for continuous determination of intratidal nonlinear dynamic compliance and resistance. The tidal volume is subdivided into a series of volume intervals called slices. For each slice, one compliance and one resistance are calculated by applying a least-squares-fit method. The volume window (width) covered by each slice is determined based on the confidence interval of the parameter estimation. The method was compared to the original SLICE method and evaluated using simulation and animal data. The ASM was also challenged with separate analysis of dynamic compliance during inspiration. If the signal-to-noise ratio (SNR) in the respiratory data decreased from +∞ to 10 dB, the relative errors of compliance increased from 0.1% to 22% for the ASM and from 0.2% to 227% for the SLICE method. Fewer differences were found in resistance. When the SNR was larger than 40 dB, the ASM delivered over 40 parameter estimates (42.2 ± 1.3). When analyzing the compliance during inspiration separately, the estimates calculated with the ASM were more stable. The adaptive determination of slice bounds results in consistent and reliable parameter values. Online analysis of nonlinear respiratory mechanics will profit from such an adaptive selection of interval size. (paper)

  5. Lysosome stabilization in slices of rat liver when incubated with vitamin A excess

    International Nuclear Information System (INIS)

    Morre, D.M.; Morre, D.J.; Bowen, S.; Reutter, W.

    1986-01-01

    An organ culture of slices of livers from adult rats was used to study effect of vitamin A (all-trans retinol) on lysosome stability. Lysosomes were purified by centrifugation in Percoll gradients. Preparations were monitored by electron microscopy and evaluated by morphometry and assays of marker enzymes. Enrichments relative to homogenates and crude pellets were estimated from latent (triton X-100) acid p-nitrophenylphosphatase specific activities. Lysosomes prepared from unincubated slices were enriched 50-fold in latent acid phosphatase relative to homogenates. In contrast, lysosomes prepared from slices incubated for 30 min in PBS alone were enriched only 20-fold. When 25 μg/ml retinol was included in the incubation medium, enrichments of 40-fold were obtained. The integrity of the slices was monitored by electron microscopy and their viability was confirmed by a sustained uptake and incorporation of [ 3 H]leucine into protein (up to 2 h in culture). The loss of lysosomes from homogenates of slices incubated in the absence of retinol was accompanied by a loss of acid phosphatase from the lysosomal pellet to the supernatant during purification. Addition of retinol to slices just prior to homogenization was without effect. The results demonstrate a stabilizing influence of vitamin A on lysosomes during incubation of licer slices. The findings contrast earlier reports of retinol-induced lysosome fragility in other in vitro systems

  6. Target recognition of ladar range images using slice image: comparison of four improved algorithms

    Science.gov (United States)

    Xia, Wenze; Han, Shaokun; Cao, Jingya; Wang, Liang; Zhai, Yu; Cheng, Yang

    2017-07-01

    Compared with traditional 3-D shape data, ladar range images possess properties of strong noise, shape degeneracy, and sparsity, which make feature extraction and representation difficult. The slice image is an effective feature descriptor to resolve this problem. We propose four improved algorithms on target recognition of ladar range images using slice image. In order to improve resolution invariance of the slice image, mean value detection instead of maximum value detection is applied in these four improved algorithms. In order to improve rotation invariance of the slice image, three new improved feature descriptors-which are feature slice image, slice-Zernike moments, and slice-Fourier moments-are applied to the last three improved algorithms, respectively. Backpropagation neural networks are used as feature classifiers in the last two improved algorithms. The performance of these four improved recognition systems is analyzed comprehensively in the aspects of the three invariances, recognition rate, and execution time. The final experiment results show that the improvements for these four algorithms reach the desired effect, the three invariances of feature descriptors are not directly related to the final recognition performance of recognition systems, and these four improved recognition systems have different performances under different conditions.

  7. Color changes and acrylamide formation in fried potato slices

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Moyano, Pedro; Kaack, Karl

    2005-01-01

    The objective of this work was to study the kinetics of browning during deep-fat frying of blanched and unblanched potato chips by using the dynamic method and to find a relationship between browning development and acrylamide formation. Prior to frying, potato slices were blanched in hot water...... at 85degreesC for 3.5 min. Unblanched slices were used as the control. Control and blanched potato slices (Panda variety, diameter: 37 mm, width: 2.2 mm) were fried at 120, 150 and 180degreesC until reaching moisture contents of similar to1.8% (total basis) and their acrylamide content and final color...... were measured. Color changes were recorded at different sampling times during frying at the three mentioned temperatures using the chromatic redness parameter a(*). Experimental data of surface temperature, moisture content and color change in potato chips during frying were fit to empirical...

  8. Thin slices and Sherlock Holmes

    African Journals Online (AJOL)

    based on very little information, and often in a matter of seconds. This is partly based on very narrow slices of our experience, and involves pattern recognition, as well as the memory banks of our senses. It is also partly a heuristic process whereby one rapidly discards ideas or notions, or promotes other hypotheses, as one.

  9. The use of transport and diffusion equations in the three-dimensional reconstruction of computerized tomographic images

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Sandrerley Ramos, E-mail: sandrerley@eee.ufg.br [Escola de Engenharia Eletrica e de Computacao - EEEC, Universidade Federal de Goias - UFG, Goiania, GO (Brazil); Flores, Edna Lucia; Pires, Dulcineia Goncalves F.; Carrijo, Gilberto Arantes; Veiga, Antonio Claudio Paschoarelli [Faculdade de Engenharia Eletrica - FEELT, Universidade Federal de Uberlandia - UFU, Uberlandia, MG (Brazil); Barcelos, Celia Aparecida Z. [Faculdade de Matematica, Universidade Federal de Uberlandia - UFU, Uberlandia, MG (Brazil)

    2012-09-15

    The visualization of a computerized tomographic (TC) exam in 3D increases the quality of the medical diagnosis and, consequently, the success probability in the treatment. To obtain a high quality image it is necessary to obtain slices which are close to one another. Motivated towards the goal of reaching an improved balance between quantity of slices and visualization quality, this research work presents a digital inpainting technique of 3D interpolation for CT slices used in the visualization of human body structures. The inpainting is carried out via non-linear partial differential equations (PDE). The PDE's have been used, in the image-processing context to fill in the damaged regions in a digital 2D image. Inspired by this idea, this article proposes an interpolation method for the filling in of the empty regions between the CT slices. To do it, considering the high similarity between two consecutive real slice, the first step of the proposed method is to create the virtual slices. The virtual slices contain all similarity between the intercalated slices and, when there are not similarities between real slices, the virtual slices will contain indefinite portions. In the second step of the proposed method, the created virtual slices will be used together with the real slices images, in the reconstruction of the structure in three dimensions, mapped onto the exam. The proposed method is capable of reconstructing the curvatures of the patient's internal structures without using slices that are close to one another. The experiments carried out show the proposed method's efficiency. (author)

  10. Time efficient whole-brain coverage with MR Fingerprinting using slice-interleaved echo-planar-imaging.

    Science.gov (United States)

    Rieger, Benedikt; Akçakaya, Mehmet; Pariente, José C; Llufriu, Sara; Martinez-Heras, Eloy; Weingärtner, Sebastian; Schad, Lothar R

    2018-04-27

    Magnetic resonance fingerprinting (MRF) is a promising method for fast simultaneous quantification of multiple tissue parameters. The objective of this study is to improve the coverage of MRF based on echo-planar imaging (MRF-EPI) by using a slice-interleaved acquisition scheme. For this, the MRF-EPI is modified to acquire several slices in a randomized interleaved manner, increasing the effective repetition time of the spoiled gradient echo readout acquisition in each slice. Per-slice matching of the signal-trace to a precomputed dictionary allows the generation of T 1 and T 2 * maps with integrated B 1 + correction. Subsequent compensation for the coil sensitivity profile and normalization to the cerebrospinal fluid additionally allows for quantitative proton density (PD) mapping. Numerical simulations are performed to optimize the number of interleaved slices. Quantification accuracy is validated in phantom scans and feasibility is demonstrated in-vivo. Numerical simulations suggest the acquisition of four slices as a trade-off between quantification precision and scan-time. Phantom results indicate good agreement with reference measurements (Difference T 1 : -2.4 ± 1.1%, T 2 *: -0.5 ± 2.5%, PD: -0.5 ± 7.2%). In-vivo whole-brain coverage of T 1 , T 2 * and PD with 32 slices was acquired within 3:36 minutes, resulting in parameter maps of high visual quality and comparable performance with single-slice MRF-EPI at 4-fold scan-time reduction.

  11. Rat brain sagittal organotypic slice cultures as an ex vivo dopamine cell loss system.

    Science.gov (United States)

    McCaughey-Chapman, Amy; Connor, Bronwen

    2017-02-01

    Organotypic brain slice cultures are a useful tool to study neurological function as they provide a more complex, 3-dimensional system than standard 2-dimensional in vitro cell cultures. Building on a previously developed mouse brain slice culture protocol, we have developed a rat sagittal brain slice culture system as an ex vivo model of dopamine cell loss. We show that rat brain organotypic slice cultures remain viable for up to 6 weeks in culture. Using Fluoro-Gold axonal tracing, we demonstrate that the slice 3-dimensional cytoarchitecture is maintained over a 4 week culturing period, with particular focus on the nigrostriatal pathway. Treatment of the cultures with 6-hydroxydopamine and desipramine induces a progressive loss of Fluoro-Gold-positive nigral cells with a sustained loss of tyrosine hydroxylase-positive nigral cells. This recapitulates the pattern of dopaminergic degeneration observed in the rat partial 6-hydroxydopamine lesion model and, most importantly, the progressive pathology of Parkinson's disease. Our slice culture platform provides an advance over other systems, as we demonstrate for the first time 3-dimensional cytoarchitecture maintenance of rat nigrostriatal sagittal slices for up to 6 weeks. Our ex vivo organotypic slice culture system provides a long term cellular platform to model Parkinson's disease, allowing for the elucidation of mechanisms involved in dopaminergic neuron degeneration and the capability to study cellular integration and plasticity ex vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Speaking in Character: Voice Communication in Virtual Worlds

    Science.gov (United States)

    Wadley, Greg; Gibbs, Martin R.

    This chapter summarizes 5 years of research on the implications of introducing voice communication systems to virtual worlds. Voice introduces both benefits and problems for players of fast-paced team games, from better coordination of groups and greater social presence of fellow players on the positive side, to negative features such as channel congestion, transmission of noise, and an unwillingness by some to use voice with strangers online. Similarly, in non-game worlds like Second Life, issues related to identity and impression management play important roles, as voice may build greater trust that is especially important for business users, yet it erodes the anonymity and ability to conceal social attributes like gender that are important for other users. A very different mixture of problems and opportunities exists when users conduct several simultaneous conversations in multiple text and voice channels. Technical difficulties still exist with current systems, including the challenge of debugging and harmonizing all the participants' voice setups. Different groups use virtual worlds for very different purposes, so a single modality may not suit all.

  13. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  14. The compact and inexpensive arrowhead setup for holographic interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Ladera, Celso L; Donoso, Guillermo, E-mail: clladera@usb.v [Departamento de Fisica, Universidad Simon BolIvar, Apdo. 89000, Caracas 1086 (Venezuela, Bolivarian Republic of)

    2011-07-15

    Hologram recording and holographic interferometry are intrinsically sensitive to phase changes, and therefore both are easily perturbed by minuscule optical path perturbations. It is therefore very convenient to bank on holographic setups with a reduced number of optical components. Here we present a compact off-axis holographic setup that requires neither a collimator nor a beam-splitter, and whose layout is reminiscent of an arrowhead. We show that this inexpensive setup is a good alternative for the study and applications of scientific holography by measuring small displacements and deformations of a body. The arrowhead setup will be found particularly useful for holography and holographic interferometry experiments and projects in teaching laboratories.

  15. Virtually teaching virtual leadership

    DEFF Research Database (Denmark)

    Henriksen, Thomas Duus; Nielsen, Rikke Kristine; Børgesen, Kenneth

    2017-01-01

    This paper seeks to investigate the challenges to virtual collaboration and leadership on basis of findings from a virtual course on collaboration and leadership. The course used for this experiment was designed as a practical approach, which allowed participants to experience curriculum phenomena....... This experimental course provided insights into the challenges involved in virtual processes, and those experiences where used for addressing the challenges that virtual leadership is confronted with. Emphasis was placed on the reduction of undesired virtual distance and its consequences through affinity building....... We found that student scepticism appeared when a breakdown resulted in increasing virtual distance, and raises questions on how leaders might translate or upgrade their understandings of leadership to handling such increased distance through affinity building....

  16. Evaluation of overall setup accuracy and adequate setup margins in pelvic image-guided radiotherapy: Comparison of the male and female patients

    International Nuclear Information System (INIS)

    Laaksomaa, Marko; Kapanen, Mika; Tulijoki, Tapio; Peltola, Seppo; Hyödynmaa, Simo; Kellokumpu-Lehtinen, Pirkko-Liisa

    2014-01-01

    We evaluated adequate setup margins for the radiotherapy (RT) of pelvic tumors based on overall position errors of bony landmarks. We also estimated the difference in setup accuracy between the male and female patients. Finally, we compared the patient rotation for 2 immobilization devices. The study cohort included consecutive 64 male and 64 female patients. Altogether, 1794 orthogonal setup images were analyzed. Observer-related deviation in image matching and the effect of patient rotation were explicitly determined. Overall systematic and random errors were calculated in 3 orthogonal directions. Anisotropic setup margins were evaluated based on residual errors after weekly image guidance. The van Herk formula was used to calculate the margins. Overall, 100 patients were immobilized with a house-made device. The patient rotation was compared against 28 patients immobilized with CIVCO's Kneefix and Feetfix. We found that the usually applied isotropic setup margin of 8 mm covered all the uncertainties related to patient setup for most RT treatments of the pelvis. However, margins of even 10.3 mm were needed for the female patients with very large pelvic target volumes centered either in the symphysis or in the sacrum containing both of these structures. This was because the effect of rotation (p ≤ 0.02) and the observer variation in image matching (p ≤ 0.04) were significantly larger for the female patients than for the male patients. Even with daily image guidance, the required margins remained larger for the women. Patient rotations were largest about the lateral axes. The difference between the required margins was only 1 mm for the 2 immobilization devices. The largest component of overall systematic position error came from patient rotation. This emphasizes the need for rotation correction. Overall, larger position errors and setup margins were observed for the female patients with pelvic cancer than for the male patients

  17. Scientific Visualization for Atmospheric Data Analysis in Collaborative Virtual Environments

    Science.gov (United States)

    Engelke, Wito; Flatken, Markus; Garcia, Arturo S.; Bar, Christian; Gerndt, Andreas

    2016-04-01

    1 INTRODUCTION The three year European research project CROSS DRIVE (Collaborative Rover Operations and Planetary Science Analysis System based on Distributed Remote and Interactive Virtual Environments) started in January 2014. The research and development within this project is motivated by three use case studies: landing site characterization, atmospheric science and rover target selection [1]. Currently the implementation for the second use case is in its final phase [2]. Here, the requirements were generated based on the domain experts input and lead to development and integration of appropriate methods for visualization and analysis of atmospheric data. The methods range from volume rendering, interactive slicing, iso-surface techniques to interactive probing. All visualization methods are integrated in DLR's Terrain Rendering application. With this, the high resolution surface data visualization can be enriched with additional methods appropriate for atmospheric data sets. This results in an integrated virtual environment where the scientist has the possibility to interactively explore his data sets directly within the correct context. The data sets include volumetric data of the martian atmosphere, precomputed two dimensional maps and vertical profiles. In most cases the surface data as well as the atmospheric data has global coverage and is of time dependent nature. Furthermore, all interaction is synchronized between different connected application instances, allowing for collaborative sessions between distant experts. 2 VISUALIZATION TECHNIQUES Also the application is currently used for visualization of data sets related to Mars the techniques can be used for other data sets as well. Currently the prototype is capable of handling 2 and 2.5D surface data as well as 4D atmospheric data. Specifically, the surface data is presented using an LoD approach which is based on the HEALPix tessellation of a sphere [3, 4, 5] and can handle data sets in the order of

  18. Measurements of the virtual bremsstrahlung yields in the p+p system

    Science.gov (United States)

    Messchendorp, J. G.; Bacelar, J. C. S.; Fülöp, J. A.; van Goethem, M. J.; Harakeh, M. N.; Hoefman, M.; Huisman, H.; Kalantar-Nayestanaki, N.; Löhner, H.; Ostendorf, R. W.; Schadmand, S.; Turrisi, R.; Volkerts, M.; Wilschut, H. W.; van der Woude, A.; Holzmann, R.; Simon, R.; Kugler, A.; Tcherkashenko, K.; Wagner, V.

    1998-03-01

    In this paper recent results obtained from the p+ p→ p+ p+ e++ e- experiment are presented. This experiment has been performed with a 190 MeV polarized proton beam obtained from the new cyclotron AGOR at KVI in Groningen. Differential cross sections have been obtained in exclusive measurements in which all four exit particles have been measured in a coincidence setup between SALAD and TAPS. The data are compared with LET calculations. A reasonable agreement is found for virtual-photon invariant masses up to 80 MeV/c 2.

  19. Measurements of the virtual bremsstrahlung yields in the p+p system

    International Nuclear Information System (INIS)

    Messchendorp, J.G.; Bacelar, J.C.S.; Fueloep, J.A.; Goethem, M.J. van; Harakeh, M.N.; Hoefman, M.; Huisman, H.; Kalantar-Nayestanaki, N.; Loehner, H.; Ostendorf, R.W.; Schadmand, S.; Turrisi, R.; Volkerts, M.; Wilschut, H.W.; Woude, A. van der; Holzmann, R.; Simon, R.; Kugler, A.; Tcherkashenko, K.; Wagner, V.

    1998-01-01

    In this paper recent results obtained from the p+p→p+p+e + +e - experiment are presented. This experiment has been performed with a 190 MeV polarized proton beam obtained from the new cyclotron AGOR at KVI in Groningen. Differential cross sections have been obtained in exclusive measurements in which all four exit particles have been measured in a coincidence setup between SALAD and TAPS. The data are compared with LET calculations. A reasonable agreement is found for virtual-photon invariant masses up to 80 MeV/c 2 . (orig.)

  20. Evaluation of two 3D virtual computer reconstructions for comparison of cleft lip and palate to normal fetal microanatomy.

    Science.gov (United States)

    Landes, Constantin A; Weichert, Frank; Geis, Philipp; Helga, Fritsch; Wagner, Mathias

    2006-03-01

    Cleft lip and palate reconstructive surgery requires thorough knowledge of normal and pathological labial, palatal, and velopharyngeal anatomy. This study compared two software algorithms and their 3D virtual anatomical reconstruction because exact 3D micromorphological reconstruction may improve learning, reveal spatial relationships, and provide data for mathematical modeling. Transverse and frontal serial sections of the midface of 18 fetal specimens (11th to 32nd gestational week) were used for two manual segmentation approaches. The first manual segmentation approach used bitmap images and either Windows-based or Mac-based SURFdriver commercial software that allowed manual contour matching, surface generation with average slice thickness, 3D triangulation, and real-time interactive virtual 3D reconstruction viewing. The second manual segmentation approach used tagged image format and platform-independent prototypical SeViSe software developed by one of the authors (F.W.). Distended or compressed structures were dynamically transformed. Registration was automatic but allowed manual correction, such as individual section thickness, surface generation, and interactive virtual 3D real-time viewing. SURFdriver permitted intuitive segmentation, easy manual offset correction, and the reconstruction showed complex spatial relationships in real time. However, frequent software crashes and erroneous landmarks appearing "out of the blue," requiring manual correction, were tedious. Individual section thickness, defined smoothing, and unlimited structure number could not be integrated. The reconstruction remained underdimensioned and not sufficiently accurate for this study's reconstruction problem. SeViSe permitted unlimited structure number, late addition of extra sections, and quantified smoothing and individual slice thickness; however, SeViSe required more elaborate work-up compared to SURFdriver, yet detailed and exact 3D reconstructions were created.

  1. An experimental set-up to test heatmoisture exchangers

    NARCIS (Netherlands)

    N. Ünal (N.); J.C. Pompe (Jan); W.P. Holland (Wim); I. Gultuna; P.E.M. Huygen; K. Jabaaij (K.); C. Ince (Can); B. Saygin (B.); H.A. Bruining (Hajo)

    1995-01-01

    textabstractObjectives: The purpose of this study was to build an experimental set-up to assess continuously the humidification, heating and resistance properties of heat-moisture exchangers (HMEs) under clinical conditions. Design: The experimental set-up consists of a patient model, measurement

  2. A new setup for the underground study of capture reactions

    CERN Document Server

    Casella, C; Lemut, A; Limata, B; Bemmerer, D; Bonetti, R; Broggini, C; Campajola, L; Cocconi, P; Corvisiero, P; Cruz, J; D'Onofrio, A; Formicola, A; Fülöp, Z; Gervino, G; Gialanella, L; Guglielmetti, A; Gustavino, C; Gyürky, G; Loiano, A; Imbriani, G; Jesus, A P; Junker, M; Musico, P; Ordine, A; Parodi, F; Parolin, M; Pinto, J V; Prati, P; Ribeiro, J P; Roca, V; Rogalla, D; Rolfs, C; Romano, M; Rossi-Alvarez, C; Rottura, A; Schuemann, F; Somorjai, E; Strieder, F; Terrasi, F; Trautvetter, H P; Vomiero, A; Zavatarelli, S

    2002-01-01

    For the study of astrophysically relevant capture reactions in the underground laboratory LUNA a new setup of high sensitivity has been implemented. The setup includes a windowless gas target, a 4 pi BGO summing crystal, and beam calorimeters. The setup has been recently used to measure the d(p,gamma) sup 3 He cross-section for the first time within its solar Gamow peak, i.e. down to 2.5 keV c.m. energy. The features of the optimized setup are described.

  3. Development of an electrically operated cassava slicing machine

    Directory of Open Access Journals (Sweden)

    I. S. Aji

    2013-08-01

    Full Text Available Labor input in manual cassava chips processing is very high and product quality is low. This paper presents the design and construction of an electrically operated cassava slicing machine that requires only one person to operate. Efficiency, portability, ease of operation, corrosion prevention of slicing component of the machine, force required to slice a cassava tuber, capacity of 10 kg/min and uniformity in the size of the cassava chips were considered in the design and fabrication of the machine. The performance of the machine was evaluated with cassava of average length and diameter of 253 mm and 60 mm respectively at an average speed of 154 rpm. The machine produced 5.3 kg of chips of 10 mm length and 60 mm diameter in 1 minute. The efficiency of the machine was 95.6% with respect to the quantity of the input cassava. The chips were found to be well chipped to the designed thickness, shape and of generally similar size. Galvanized steel sheets were used in the cutting section to avoid corrosion of components. The machine is portable and easy to operate which can be adopted for cassava processing in a medium size industry.

  4. Simple optical setup implementation for digital Fourier transform holography

    Energy Technology Data Exchange (ETDEWEB)

    De Oliveira, G N [Pos-graduacao em Engenharia Mecanica, TEM/PGMEC, Universidade Federal Fluminense, Rua Passo da Patria, 156, Niteroi, R.J., Cep.: 24.210-240 (Brazil); Rodrigues, D M C; Dos Santos, P A M, E-mail: pams@if.uff.br [Instituto de Fisica, Laboratorio de Optica Nao-linear e Aplicada, Universidade Federal Fluminense, Av. Gal. Nilton Tavares de Souza, s/n, Gragoata, Niteroi, R.J., Cep.:24.210-346 (Brazil)

    2011-01-01

    In the present work a simple implementation of Digital Fourier Transform Holography (DFTH) setup is discussed. This is obtained making a very simple modification in the classical setup arquiteture of the Fourier Transform holography. It is also demonstrated the easy and practical viability of the setup in an interferometric application for mechanical parameters determination. The work is also proposed as an interesting advanced introductory training for graduated students in digital holography.

  5. Novel culturing platform for brain slices and neuronal cells

    DEFF Research Database (Denmark)

    Svendsen, Winnie Edith; Al Atraktchi, Fatima Al-Zahraa; Bakmand, Tanya

    2015-01-01

    In this paper we demonstrate a novel culturing system for brain slices and neuronal cells, which can control the concentration of nutrients and the waste removal from the culture by adjusting the fluid flow within the device. The entire system can be placed in an incubator. The system has been...... tested successfully with brain slices and PC12 cells. The culture substrate can be modified using metal electrodes and/or nanostructures for conducting electrical measurements while culturing and for better mimicking the in vivo conditions....

  6. The use of a wax bite wafer and a double computed tomography scan procedure to obtain a three-dimensional augmented virtual skull model.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mommaerts, M.Y.; Abeloos, J.V.S.; Clercq, C. De; Lamoral, P.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2007-01-01

    A detailed visualization of the interocclusal relationship is essential in a three-dimensional virtual planning setup for orthognathic and facial orthomorphic surgery. The purpose of this study was to introduce and evaluate the use of a wax bite wafer in combination with a double computed tomography

  7. Analysis of patient setup accuracy using electronic portal imaging device

    International Nuclear Information System (INIS)

    Onogi, Yuzo; Aoki, Yukimasa; Nakagawa, Keiichi

    1996-01-01

    Radiation therapy is performed in many fractions, and accurate patient setup is very important. This is more significant nowadays because treatment planning and radiation therapy are more precisely performed. Electronic portal imaging devices and automatic image comparison algorithms let us analyze setup deviations quantitatively. With such in mind we developed a simple image comparison algorithm. Using 2459 electronic verification images (335 ports, 123 treatment sites) generated during the past three years at our institute, we evaluated the results of the algorithm, and analyzed setup deviations according to the area irradiated, use of a fixing device (shell), and arm position. Calculated setup deviation was verified visually and their fitness was classified into good, fair, bad, and incomplete. The result was 40%, 14%, 22%, 24% respectively. Using calculated deviations classified as good (994 images), we analyzed setup deviations. Overall setup deviations described in 1 SD along axes x, y, z, was 1.9 mm, 2.5 mm, 1.7 mm respectively. We classified these deviations into systematic and random components, and found that random error was predominant in our institute. The setup deviations along axis y (cranio-caudal direction) showed larger distribution when treatment was performed with the shell. Deviations along y (cranio-caudal) and z (anterior-posterior) had larger distribution when treatment occurred with the patient's arm elevated. There was a significant time-trend error, whose deviations become greater with time. Within all evaluated ports, 30% showed a time-trend error. Using an electronic portal imaging device and automatic image comparison algorithm, we are able to analyze setup deviations more precisely and improve setup method based on objective criteria. (author)

  8. Intersection Based Motion Correction of Multi-Slice MRI for 3D in utero Fetal Brain Image Formation

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A.; Rousseau, Francois; Glenn, Orit A.; Barkovich, Anthony J.; Studholme, Colin

    2012-01-01

    In recent years post-processing of fast multi-slice MR imaging to correct fetal motion has provided the first true 3D MR images of the developing human brain in utero. Early approaches have used reconstruction based algorithms, employing a two step iterative process, where slices from the acquired data are re-aligned to an approximate 3D reconstruction of the fetal brain, which is then refined further using the improved slice alignment. This two step slice-to-volume process, although powerful, is computationally expensive in needing a 3D reconstruction, and is limited in its ability to recover sub-voxel alignment. Here, we describe an alternative approach which we term slice intersection motion correction (SIMC), that seeks to directly co-align multiple slice stacks by considering the matching structure along all intersecting slice pairs in all orthogonally planned slices that are acquired in clinical imaging studies. A collective update scheme for all slices is then derived, to simultaneously drive slices into a consistent match along their lines of intersection. We then describe a 3D reconstruction algorithm that, using the final motion corrected slice locations, suppresses through-plane partial volume effects to provide a single high isotropic resolution 3D image. The method is tested on simulated data with known motions and is applied to retrospectively reconstruct 3D images from a range of clinically acquired imaging studies. The quantitative evaluation of the registration accuracy for the simulated data sets demonstrated a significant improvement over previous approaches. An initial application of the technique to studying clinical pathology is included, where the proposed method recovered up to 15 mm of translation and 30 degrees of rotation for individual slices, and produced full 3D reconstructions containing clinically useful additional information not visible in the original 2D slices. PMID:19744911

  9. A fourth gradient to overcome slice dependent phase effects of voxel-sized coils in planar arrays.

    Science.gov (United States)

    Bosshard, John C; Eigenbrodt, Edwin P; McDougall, Mary P; Wright, Steven M

    2010-01-01

    The signals from an array of densely spaced long and narrow receive coils for MRI are complicated when the voxel size is of comparable dimension to the coil size. The RF coil causes a phase gradient across each voxel, which is dependent on the distance from the coil, resulting in a slice dependent shift of k-space. A fourth gradient coil has been implemented and used with the system's gradient set to create a gradient field which varies with slice. The gradients are pulsed together to impart a slice dependent phase gradient to compensate for the slice dependent phase due to the RF coils. However the non-linearity in the fourth gradient which creates the desired slice dependency also results in a through-slice phase ramp, which disturbs normal slice refocusing and leads to additional signal cancelation and reduced field of view. This paper discusses the benefits and limitations of using a fourth gradient coil to compensate for the phase due to RF coils.

  10. Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Ganesh, Tharmar; Rath, Goura K.; Julka, Pramod K.; Sridhar, Pappiah S.; Joshi, Rakesh C.; Thulkar, Sanjay

    2009-01-01

    The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume 25 cc

  11. Virtual anthropology: useful radiological tools for age assessment in clinical forensic medicine and thanatology.

    Science.gov (United States)

    Dedouit, Fabrice; Saint-Martin, Pauline; Mokrane, Fatima-Zohra; Savall, Frédéric; Rousseau, Hervé; Crubézy, Eric; Rougé, Daniel; Telmon, Norbert

    2015-09-01

    Virtual anthropology consists of the introduction of modern slice imaging to biological and forensic anthropology. Thanks to this non-invasive scientific revolution, some classifications and staging systems, first based on dry bone analysis, can be applied to cadavers with no need for specific preparation, as well as to living persons. Estimation of bone and dental age is one of the possibilities offered by radiology. Biological age can be estimated in clinical forensic medicine as well as in living persons. Virtual anthropology may also help the forensic pathologist to estimate a deceased person's age at death, which together with sex, geographical origin and stature, is one of the important features determining a biological profile used in reconstructive identification. For this forensic purpose, the radiological tools used are multislice computed tomography and, more recently, X-ray free imaging techniques such as magnetic resonance imaging and ultrasound investigations. We present and discuss the value of these investigations for age estimation in anthropology.

  12. The COMPASS Setup for Physics with Hadron Beams

    CERN Document Server

    Abbon, Ph.; Akhunzyanov, R.; Alexandrov, Yu.; Alexeev, M.G.; Alexeev, G.D.; Amoroso, A.; Andrieux, V.; Anosov, V.; Austregesilo, A.; Badelek, B.; Balestra, F.; Barth, J.; Baum, G.; Beck, R.; Bedfer, Y.; Berlin, A.; Bernhard, J.; Bicker, K.; Bielert, E.R.; Bieling, J.; Birsa, R.; Bisplinghoff, J.; Bodlak, M.; Boer, M.; Bordalo, P.; Bradamante, F.; Braun, C.; Bressan, A.; Buchele, M.; Burtin, E.; Capozza, L.; Ciliberti, P.; Chiosso, M.; Chung, S.U.; Cicuttin, A.; Colantoni, M.; Cotte, D.; Crespo, M.L.; Curiel, Q.; Dafni, T.; Dalla Torre, S.; Dasgupta, S.S.; Dasgupta, S.; Denisov, O.Yu.; Desforge, D.; Dinkelbach, A.M.; Donskov, S.V.; Doshita, N.; Duic, V.; Dunnweber, W.; Durand, D.; Dziewiecki, M.; Efremov, A.; Elia, C.; Eversheim, P.D.; Eyrich, W.; Faessler, M.; Ferrero, A.; Finger, M.; M. Finger jr; Fischer, H.; Franco, C.; von Hohenesche, N. du Fresne; Friedrich, J.M.; Frolov, V.; Gatignon, L.; Gautheron, F.; Gavrichtchouk, O.P.; Gerassimov, S.; Geyer, R.; Giganon, A.; Gnesi, I.; Gobbo, B.; Goertz, S.; Gorzellik, M.; Grabmuller, S.; Grasso, A.; Gregori, M.; Grube, B.; Grussenmeyer, T.; Guskov, A.; Haas, F.; von Harrach, D.; Hahne, D.; Hashimoto, R.; Heinsius, F.H.; Herrmann, F.; Hinterberger, F.; Hoppner, Ch.; Horikawa, N.; d'Hose, N.; Huber, S.; Ishimoto, S.; Ivanov, A.; Ivanshin, Yu.; Iwata, T.; Jahn, R.; Jary, V.; Jasinski, P.; Jorg, P.; Joosten, R.; Kabuss, E.; Ketzer, B.; Khaustov, G.V.; Khokhlov, Yu. A.; Kisselev, Yu.; Klein, F.; Klimaszewski, K.; Koivuniemi, J.H.; Kolosov, V.N.; Kondo, K.; Konigsmann, K.; Konorov, I.; Konstantinov, V.F.; Kotzinian, A.M.; Kouznetsov, O.; Kramer, M.; Kroumchtein, Z.V.; Kuchinski, N.; Kuhn, R.; Kunne, F.; Kurek, K.; Kurjata, R.P.; Lednev, A.A.; Lehmann, A.; Levillain, M.; Levorato, S.; Lichtenstadt, J.; Maggiora, A.; Magnon, A.; Makke, N.; Mallot, G.K.; Marchand, C.; Marroncle, J.; Martin, A.; Marzec, J.; Matousek, J.; Matsuda, H.; Matsuda, T.; Menon, G.; Meshcheryakov, G.; Meyer, W.; Michigami, T.; Mikhailov, Yu. V.; Miyachi, Y.; Moinester, M.A.; Nagaytsev, A.; Nagel, T.; Nerling, F.; Neubert, S.; Neyret, D.; Nikolaenko, V.I.; Novy, J.; Nowak, W.D.; Nunes, Ana Sofia; Olshevsky, A.G.; Orlov, I.; Ostrick, M.; Panknin, R.; Panzieri, D.; Parsamyan, B.; Paul, S.; Pesaro, G.; Pesaro, V.; Peshekhonov, D.V.; Pires, C.; Platchkov, S.; Pochodzalla, J.; Polyakov, V.A.; Pretz, J.; Quaresma, M.; Quintans, C.; Ramos, S.; Regali, C.; Reicherz, G.; Reymond, J-M.; Rocco, E.; Rossiyskaya, N.S.; Rousse, J.Y.; Ryabchikov, D.I.; Rychter, A.; Samartsev, A.; Samoylenko, V.D.; Sandacz, A.; Sarkar, S.; Savin, I.A.; Sbrizzai, G.; Schiavon, P.; Schill, C.; Schluter, T.; Schmidt, K.; Schmieden, H.; Schonning, K.; Schopferer, S.; Schott, M.; Shevchenko, O.Yu.; Silva, L.; Sinha, L.; Sirtl, S.; Slunecka, M.; Sosio, S.; Sozzi, F.; Srnka, A.; Steiger, L.; Stolarski, M.; Sulc, M.; Sulej, R.; Suzuki, H.; Szabelski, A.; Szameitat, T.; Sznajder, P.; Takekawa, S.; Wolbeek, J. ter; Tessaro, S.; Tessarotto, F.; Thibaud, F.; Tskhay, V.; Uhl, S.; Uman, I.; Virius, M.; Wang, L.; Weisrock, T.; Weitzel, Q.; Wilfert, M.; Windmolders, R.; Wollny, H.; Zaremba, K.; Zavertyaev, M.; Zemlyanichkina, E.; Ziembicki, M.; Zink, A.

    2015-01-01

    The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successfully used with positive and negative hadron beams and with liquid hydrogen and solid nuclear targets. This article describes the new and upgraded detectors and auxiliary equipment, outlines the reconstruction procedures used, and summarises the general performance of the setup.

  13. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  14. Fan beam image reconstruction with generalized Fourier slice theorem.

    Science.gov (United States)

    Zhao, Shuangren; Yang, Kang; Yang, Kevin

    2014-01-01

    For parallel beam geometry the Fourier reconstruction works via the Fourier slice theorem (or central slice theorem, projection slice theorem). For fan beam situation, Fourier slice can be extended to a generalized Fourier slice theorem (GFST) for fan-beam image reconstruction. We have briefly introduced this method in a conference. This paper reintroduces the GFST method for fan beam geometry in details. The GFST method can be described as following: the Fourier plane is filled by adding up the contributions from all fanbeam projections individually; thereby the values in the Fourier plane are directly calculated for Cartesian coordinates such avoiding the interpolation from polar to Cartesian coordinates in the Fourier domain; inverse fast Fourier transform is applied to the image in Fourier plane and leads to a reconstructed image in spacial domain. The reconstructed image is compared between the result of the GFST method and the result from the filtered backprojection (FBP) method. The major differences of the GFST and the FBP methods are: (1) The interpolation process are at different data sets. The interpolation of the GFST method is at projection data. The interpolation of the FBP method is at filtered projection data. (2) The filtering process are done in different places. The filtering process of the GFST is at Fourier domain. The filtering process of the FBP method is the ramp filter which is done at projections. The resolution of ramp filter is variable with different location but the filter in the Fourier domain lead to resolution invariable with location. One advantage of the GFST method over the FBP method is in short scan situation, an exact solution can be obtained with the GFST method, but it can not be obtained with the FBP method. The calculation of both the GFST and the FBP methods are at O(N^3), where N is the number of pixel in one dimension.

  15. Virtual Reality Compared with Bench-Top Simulation in the Acquisition of Arthroscopic Skill: A Randomized Controlled Trial.

    Science.gov (United States)

    Banaszek, Daniel; You, Daniel; Chang, Justues; Pickell, Michael; Hesse, Daniel; Hopman, Wilma M; Borschneck, Daniel; Bardana, Davide

    2017-04-05

    Work-hour restrictions as set forth by the Accreditation Council for Graduate Medical Education (ACGME) and other governing bodies have forced training programs to seek out new learning tools to accelerate acquisition of both medical skills and knowledge. As a result, competency-based training has become an important part of residency training. The purpose of this study was to directly compare arthroscopic skill acquisition in both high-fidelity and low-fidelity simulator models and to assess skill transfer from either modality to a cadaveric specimen, simulating intraoperative conditions. Forty surgical novices (pre-clerkship-level medical students) voluntarily participated in this trial. Baseline demographic data, as well as data on arthroscopic knowledge and skill, were collected prior to training. Subjects were randomized to 5-week independent training sessions on a high-fidelity virtual reality arthroscopic simulator or on a bench-top arthroscopic setup, or to an untrained control group. Post-training, subjects were asked to perform a diagnostic arthroscopy on both simulators and in a simulated intraoperative environment on a cadaveric knee. A more difficult surprise task was also incorporated to evaluate skill transfer. Subjects were evaluated using the Global Rating Scale (GRS), the 14-point arthroscopic checklist, and a timer to determine procedural efficiency (time per task). Secondary outcomes focused on objective measures of virtual reality simulator motion analysis. Trainees on both simulators demonstrated a significant improvement (p virtual reality simulation group consistently outperformed the bench-top model group in the diagnostic arthroscopy crossover tests and in the simulated cadaveric setup. Furthermore, the virtual reality group demonstrated superior skill transfer in the surprise skill transfer task. Both high-fidelity and low-fidelity simulation trainings were effective in arthroscopic skill acquisition. High-fidelity virtual reality

  16. Relationship between moisture content and electrical impedance of carrot slices during drying

    Science.gov (United States)

    Kertész, Ákos; Hlaváčová, Zuzana; Vozáry, Eszter; Staroňová, Lenka

    2015-01-01

    Electrical properties of food materials can give information about the inner structure and physiological state of biological tissues. Generally, the process of drying of fruits and vegetables is followed by weight loss. The aim of this study was to measure the impedance spectra of carrot slices during drying and to correlate impedance parameters to moisture content in different drying periods. Cylindrical slices were cut out from the carrot root along the axis. The slices were dried in a Venticell 111 air oven at 50°C. The weight of the slices was measured with a Denver SI-603 electronic analytical and precision balance. The weighing of the samples was performed every 30 min at the beginning of drying and every 60 min after the process. The moisture content of the samples was calculated on wet basis. The magnitude and phase angle of electrical impedance of the slices were measured with HP 4284A and 4285A precision LCR meters in the frequency range from 30 Hz to 1 MHz and from 75 kHz to 30 MHz, respectively, at voltage 1 V. The impedance measurement was performed after weighting. The change in the magnitude of impedance during drying showed a good correlation with the change in the moisture content.

  17. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Real-time slicing algorithm for Stereolithography (STL) CAD model applied in additive manufacturing industry

    Science.gov (United States)

    Adnan, F. A.; Romlay, F. R. M.; Shafiq, M.

    2018-04-01

    Owing to the advent of the industrial revolution 4.0, the need for further evaluating processes applied in the additive manufacturing application particularly the computational process for slicing is non-trivial. This paper evaluates a real-time slicing algorithm for slicing an STL formatted computer-aided design (CAD). A line-plane intersection equation was applied to perform the slicing procedure at any given height. The application of this algorithm has found to provide a better computational time regardless the number of facet in the STL model. The performance of this algorithm is evaluated by comparing the results of the computational time for different geometry.

  19. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology.

    Science.gov (United States)

    Colman, Kerri L; Dobbe, Johannes G G; Stull, Kyra E; Ruijter, Jan M; Oostra, Roelof-Jan; van Rijn, Rick R; van der Merwe, Alie E; de Boer, Hans H; Streekstra, Geert J

    2017-07-01

    Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical computed tomography (CT) scans provides a potential solution. However, clinical CT scans are typically generated with varying settings. This study investigates the effects of image segmentation and varying imaging conditions on the precision of virtual modelled pelves. An adult human cadaver was scanned using varying imaging conditions, such as scanner type and standard patient scanning protocol, slice thickness and exposure level. The pelvis was segmented from the various CT images resulting in virtually modelled pelves. The precision of the virtual modelling was determined per polygon mesh point. The fraction of mesh points resulting in point-to-point distance variations of 2 mm or less (95% confidence interval (CI)) was reported. Colour mapping was used to visualise modelling variability. At almost all (>97%) locations across the pelvis, the point-to-point distance variation is less than 2 mm (CI = 95%). In >91% of the locations, the point-to-point distance variation was less than 1 mm (CI = 95%). This indicates that the geometric variability of the virtual pelvis as a result of segmentation and imaging conditions rarely exceeds the generally accepted linear error of 2 mm. Colour mapping shows that areas with large variability are predominantly joint surfaces. Therefore, results indicate that segmented bone elements from patient-derived CT scans are a sufficiently precise source for creating a virtual skeletal database.

  20. Antibrowning and antimicrobial properties of sodium acid sulfate in apple slices.

    Science.gov (United States)

    Fan, Xuetong; Sokorai, Kimberly J B; Liao, Ching-Hsing; Cooke, Peter; Zhang, Howard Q

    2009-01-01

    There are few available compounds that can both control browning and enhance microbial safety of fresh-cut fruits. In the present study, the antibrowning ability of sodium acid sulfate (SAS) on "Granny Smith" apple slices was first investigated in terms of optimum concentration and treatment time. In a separate experiment, the apple slices were treated with water or 3% of SAS, calcium ascorbate, citric acid, or acidified calcium sulfate for 5 min. Total plate count, color, firmness, and tissue damage were assessed during a 21-d storage at 4 degrees C. Results showed that the efficacy of SAS in inhibiting browning of apple slices increased with increasing concentration. A minimum 3% of SAS was needed to achieve 14 d of shelf life. Firmness was not significantly affected by SAS at 3% or lower concentrations. Antibrowning potential of SAS was similar for all treatment times ranging from 2 to 10 min. However, SAS caused some skin discoloration of apple slices. When cut surface of apple slices were stained with a fluorescein diacetate solution, tissue damage could be observed under a microscope even though visual damage was not evident. Among the antibrowning agents tested, SAS was the most effective in inhibiting browning and microbial growth for the first 14 d. Total plate count of samples treated with 3% SAS was significantly lower than those treated with calcium ascorbate, a commonly used antibrowning agent. Our results suggested that it is possible to use SAS to control browning while inhibiting the growth of microorganisms on the apple slices if the skin damage can be minimized. Practical Application: Fresh-cut apples have emerged as one of the popular products in restaurants, schools, and food service establishments as more consumers demand fresh, convenient, and nutritious foods. Processing of fresh-cut apples induces mechanical damage to the fruit and exposes apple tissue to air, resulting in the development of undesirable tissue browning. The fresh

  1. Concept and development of measurement method of time sensitivity profile (TSP) in X-ray CT. Comparison of non-helical, single-slice helical, and multi-slice helical scans

    International Nuclear Information System (INIS)

    Tsujioka, Katsumi; Ida, Yoshihiro; Ohtsubo, Hironori; Takahashi, Yasukata; Niwa, Masayoshi

    2000-01-01

    We focused on the time element contained in a single CT image, and devised the concept of a time-sensitivity profile (TSP) describing how the time element is translated into an image. We calculated the data collection time range when the helical pitch is changed in non helical scans, single slice helical scans, and multi slice helical scans. We then calculated the time sensitivity profile (TSP) from the weighting applied when the data collection time range is translated into an image. TSP was also measured for each scanning method using our self-made moving phantom. TSPs obtained from the calculation and the experiments were very close. TSP showed interesting characteristics with each scanning method, especially in the case of multi slice helical scanning, in which TSP became shorter as helical pitch increased. We referred to the TSP's FWHM as the effective scanning time. When we conducted multi slice helical scanning at helical pitch 3, the effective scanning time increased to about 24% longer than that of a non helical scan. When we conducted multi slice helical scanning at helical pitch 5 or 6, the effective scanning time was about half that of a non helical scan. The time sensitivity profile (TSP) is a totally new concept that we consider an important element in discussing the time resolution of a CT scanner. The results of this review will provide significant data in determining the scanning parameters when scanning a moving object. (author)

  2. Microbiological quality of sliced and block mozzarella cheese

    Directory of Open Access Journals (Sweden)

    Mariana Fontanetti Marinheiro

    2015-06-01

    Full Text Available The aim of this study was to verify the microbiological quality of mozzarella cheese sold in retail markets of Pelotas, Rio Grande do Sul, Brazil. Forty samples of mozzarella cheese were analyzed, comprising 20 samples of block cheese and 20 of sliced cheese. The cheese samples were analyzed for thermotolerant coliform counts and coagulase positive staphylococci counts, and presence of Salmonella spp and Listeria monocytogenes. The percentage of 12,5% and 5% of the sliced and block cheese samples analyzed, respectively, exceeded the microbiological standards accepted by Brazilian legislation. These results indicate the need for a better product monitoring and more concern with hygiene and sanitary practices during industrial process.

  3. Trafficking of astrocytic vesicles in hippocampal slices

    International Nuclear Information System (INIS)

    Potokar, Maja; Kreft, Marko; Lee, So-Young; Takano, Hajime; Haydon, Philip G.; Zorec, Robert

    2009-01-01

    The increasingly appreciated role of astrocytes in neurophysiology dictates a thorough understanding of the mechanisms underlying the communication between astrocytes and neurons. In particular, the uptake and release of signaling substances into/from astrocytes is considered as crucial. The release of different gliotransmitters involves regulated exocytosis, consisting of the fusion between the vesicle and the plasma membranes. After fusion with the plasma membrane vesicles may be retrieved into the cytoplasm and may continue to recycle. To study the mobility implicated in the retrieval of secretory vesicles, these structures have been previously efficiently and specifically labeled in cultured astrocytes, by exposing live cells to primary and secondary antibodies. Since the vesicle labeling and the vesicle mobility properties may be an artifact of cell culture conditions, we here asked whether the retrieving exocytotic vesicles can be labeled in brain tissue slices and whether their mobility differs to that observed in cell cultures. We labeled astrocytic vesicles and recorded their mobility with two-photon microscopy in hippocampal slices from transgenic mice with fluorescently tagged astrocytes (GFP mice) and in wild-type mice with astrocytes labeled by Fluo4 fluorescence indicator. Glutamatergic vesicles and peptidergic granules were labeled by the anti-vesicular glutamate transporter 1 (vGlut1) and anti-atrial natriuretic peptide (ANP) antibodies, respectively. We report that the vesicle mobility parameters (velocity, maximal displacement and track length) recorded in astrocytes from tissue slices are similar to those reported previously in cultured astrocytes.

  4. A multi-slice sliding cell technique for diffusion measurements in liquid metals

    Science.gov (United States)

    Zhong, Langxiang; Hu, Jinliang; Geng, Yongliang; Zhu, Chunao; Zhang, Bo

    2017-09-01

    The long capillary and shear-cell techniques are traditionally used for diffusion measurements in liquid metals. Inspired by the idea of the shear-cell method, we have built a multi-slice sliding cell device for inter-diffusion measurements in liquid metals. The device is designed based on a linear sliding movement rather than a rotational shearing as used in the traditional shear-cell method. Compared with the normal shear-cell method, the present device is a more compact setup thus easier to handle. Also, it is expected to be easier to monitor with X-rays or neutrons if used in in situ experiments. A series of benchmark time-dependent diffusion experiments in Al-Cu melts carried out with the present technique reveal that accurate diffusion constants can be achieved only after a sufficient time. For short annealing times, the initial shearing process causing convective flow dominates the measurement and leads to an increase of the measured diffusion coefficient by a factor three. The diffusion data obtained for Al-Cu liquids are consistent with the most accurate data measured by the in situ X-ray radiography method under well controlled conditions of no temperature gradient or other perturbation. High accuracy and easy handling as well as superior adaptability make the present technique suitable for diffusion studies in liquid metals.

  5. Capitalizing Resolving Power of Density Gradient Ultracentrifugation by Freezing and Precisely Slicing Centrifuged Solution: Enabling Identification of Complex Proteins from Mitochondria by Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Haiqing Yu

    2016-01-01

    Full Text Available Density gradient centrifugation is widely utilized for various high purity sample preparations, and density gradient ultracentrifugation (DGU is often used for more resolution-demanding purification of organelles and protein complexes. Accurately locating different isopycnic layers and precisely extracting solutions from these layers play a critical role in achieving high-resolution DGU separations. In this technique note, we develop a DGU procedure by freezing the solution rapidly (but gently after centrifugation to fix the resolved layers and by slicing the frozen solution to fractionate the sample. Because the thickness of each slice can be controlled to be as thin as 10 micrometers, we retain virtually all the resolution produced by DGU. To demonstrate the effectiveness of this method, we fractionate complex V from HeLa mitochondria using a conventional technique and this freezing-slicing (F-S method. The comparison indicates that our F-S method can reduce complex V layer thicknesses by ~40%. After fractionation, we analyze complex V proteins directly on a matrix assisted laser desorption/ionization, time-of-flight mass spectrometer. Twelve out of fifteen subunits of complex V are positively identified. Our method provides a practical protocol to identify proteins from complexes, which is useful to investigate biomolecular complexes and pathways in various conditions and cell types.

  6. Set-Up and Punchline as Figure and Ground

    DEFF Research Database (Denmark)

    Keisalo, Marianna Päivikki

    the two that cannot be resolved by appeal to either set-up or punchline, but traps thought between them in an ‘epistemological problem’ as comedian Louis CK put it. For comedians, set-ups and punchlines are basic tools, practical and concrete ways to create and organize material. They are also familiar...

  7. Pre-sliced fruit in school cafeterias: children's selection and intake.

    Science.gov (United States)

    Wansink, Brian; Just, David R; Hanks, Andrew S; Smith, Laura E

    2013-05-01

    It is often assumed that children avoid fruit in school cafeterias because of higher relative prices and preferences for other foods. Interviews with children reveal that eating whole fresh fruit can be difficult for those with small mouths or braces. Older girls find whole fruits messy and unattractive to eat. To determine the effect of offering pre-sliced fruit in schools on selection and intake. Three of six schools were assigned randomly to serve apples in slices. Three control schools served apples whole. Selection, consumption, and waste of apples were measured prior to and during treatment. Cafeterias in six public middle schools in Wayne County NY in 2011. Participants included all students who purchased lunch on days when data were collected. Treatment schools were provided with a standard commercial fruit slicer, and cafeteria staff members were instructed to use it when students requested apples. Trained researchers recorded how much of each apple was consumed and how much was wasted in both control and treatment schools. Daily apple sales, percentage of an apple serving consumed per student, and percentage of an apple serving wasted per student. Data were analyzed in 2012. Schools that used fruit slicers to pre-slice fruit increased average daily apple sales by 71% compared to control schools (papples and ate more than half increased by 73% (p=0.02) at schools that served pre-sliced fruit, and the percentage that wasted half or more decreased by 48% (p=0.03). Sliced fruit is more appealing to children than whole fruit because it is easier and tidier to eat. This study applies the principle of convenience from behavioral economics and provides an example of a scalable, low-cost environmental change that promotes healthy eating and decreases waste. Copyright © 2013. Published by Elsevier Inc. on behalf of American Journal of Preventive Medicine.

  8. Influence of image slice thickness on rectal dose–response relationships following radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Olsson, C; Thor, M; Apte, A; Deasy, J O; Liu, M; Moissenko, V; Petersen, S E; Høyer, M

    2014-01-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose–response relationships. We investigated this for rectal bleeding using dose–volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman–Kutcher–Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose–response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice

  9. Dried fruit breadfruit slices by Refractive Window™ technique

    Directory of Open Access Journals (Sweden)

    Diego F. Tirado

    2016-01-01

    Full Text Available A large amount of products are dried due several reasons as preservation, weight reduction and improvement of stability. However, on the market are not offered low-cost and high quality products simultaneously. Although there are effective methods of dehydrating foods such as freeze drying, which preserves the flavor, color and vitamins, they are poor accessibility technologies. Therefore, alternative processes are required to be efficient and economical. The aim of this research was compare drying kinetics of sliced of breadfruit (Artocarpus communis using the technique of Refractive Window® (VR with the tray drying. To carry out this study, sliced of 1 and 2 mm thick were used. Refractive window drying was performed with the water bath temperature to 92 °C; and tray drying at 62 °C and an air velocity of 0.52 m/s. During the Refractive window drying technique, the moisture content reached the lower than tray drying levels. Similarly it happened with samples of 1 mm, which, having a smaller diameter reached lower moisture levels than samples 2 mm. The higher diffusivities were obtained during drying sliced VR 1 and 2 mm with coefficients of 6.13 and 3.90*10-9 m2/s respectively.

  10. Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy

    International Nuclear Information System (INIS)

    Cho, Jeong Hee; Lee, Sang Kyu; Kim, Sei Joon; Na, Soo Kyung

    2007-01-01

    The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the

  11. Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jeong Hee; Lee, Sang Kyu [Dept. of Radiation Oncology, Yensei Univesity Health System, Seoul (Korea, Republic of); Kim, Sei Joon [Dept. of Radiation Oncology,Yongdong Severance Hospital , Seoul (Korea, Republic of); Na, Soo Kyung [Dept. of Radiological Science, Gimcheon College, Gimcheon (Korea, Republic of)

    2007-09-15

    The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were

  12. Virtual goods recommendations in virtual worlds.

    Science.gov (United States)

    Chen, Kuan-Yu; Liao, Hsiu-Yu; Chen, Jyun-Hung; Liu, Duen-Ren

    2015-01-01

    Virtual worlds (VWs) are computer-simulated environments which allow users to create their own virtual character as an avatar. With the rapidly growing user volume in VWs, platform providers launch virtual goods in haste and stampede users to increase sales revenue. However, the rapidity of development incurs virtual unrelated items which will be difficult to remarket. It not only wastes virtual global companies' intelligence resources, but also makes it difficult for users to find suitable virtual goods fit for their virtual home in daily virtual life. In the VWs, users decorate their houses, visit others' homes, create families, host parties, and so forth. Users establish their social life circles through these activities. This research proposes a novel virtual goods recommendation method based on these social interactions. The contact strength and contact influence result from interactions with social neighbors and influence users' buying intention. Our research highlights the importance of social interactions in virtual goods recommendation. The experiment's data were retrieved from an online VW platform, and the results show that the proposed method, considering social interactions and social life circle, has better performance than existing recommendation methods.

  13. Application of video imaging for improvement of patient set-up

    International Nuclear Information System (INIS)

    Ploeger, Lennert S.; Frenay, Michel; Betgen, Anja; Bois, Josien A. de; Gilhuijs, Kenneth G.A.; Herk, Marcel van

    2003-01-01

    Background and purpose: For radiotherapy of prostate cancer, the patient is usually positioned in the left-right (LR) direction by aligning a single marker on the skin with the projection of a room laser. The aim of this study is to investigate the feasibility of a room-mounted video camera in combination with previously acquired CT data to improve patient set-up along the LR axis. Material and methods: The camera was mounted in the treatment room at the caudal side of the patient. For 22 patients with prostate cancer 127 video and portal images were acquired. The set-up error determined by video imaging was found by matching video images with rendered CT images using various techniques. This set-up error was retrospectively compared with the set-up error derived from portal images. It was investigated whether the number of corrections based on portal imaging would decrease if the information obtained from the video images had been used prior to irradiation. Movement of the skin with respect to bone was quantified using an analysis of variance method. Results: The measurement of the set-up error was most accurate for a technique where outlines and groins on the left and right side of the patient were delineated and aligned individually to the corresponding features extracted from the rendered CT image. The standard deviations (SD) of the systematic and random components of the set-up errors derived from the portal images in the LR direction were 1.5 and 2.1 mm, respectively. When the set-up of the patients was retrospectively adjusted based on the video images, the SD of the systematic and random errors decreased to 1.1 and 1.3 mm, respectively. From retrospective analysis, a reduction of the number of set-up corrections (from nine to six corrections) is expected when the set-up would have been adjusted using the video images. The SD of the magnitude of motion of the skin of the patient with respect to the bony anatomy was estimated to be 1.1 mm. Conclusion: Video

  14. Blanching, salting and sun drying of different pumpkin fruit slices.

    Science.gov (United States)

    Workneh, T S; Zinash, A; Woldetsadik, K

    2014-11-01

    The study was aimed at assessing the quality of pumpkin (Cucuribita Spp.) slices that were subjected to pre-drying treatments and drying using two drying methods (uncontrolled sun and oven) fruit accessions. Pre-drying had significant (P ≤ 0.05) effect on the quality of dried pumpkin slices. 10 % salt solution dipped pumpkin fruit slices had good chemical quality. The two-way interaction between drying methods and pre-drying treatments had significant (P ≤ 0.05) effect on chemical qualities. Pumpkin subjected to salt solution dipping treatment and oven dried had higher chemical concentrations. Among the pumpkin fruit accessions, pumpkin accession 8007 had the superior TSS, total sugar and sugar to acid ratio after drying. Among the three pre-drying treatment, salt solution dipping treatment had significant (P ≤ 0.05) effect and the most efficient pre-drying treatment to retain the quality of dried pumpkin fruits without significant chemical quality deterioration. Salt dipping treatment combined with low temperature (60 °C) oven air circulation drying is recommended to maintain quality of dried pumpkin slices. However, since direct sun drying needs extended drying time due to fluctuation in temperature, it is recommended to develop or select best successful solar dryer for use in combination with pre-drying salt dipping or blanching treatments.

  15. Automatic Solitary Lung Nodule Detection in Computed Tomography Images Slices

    Science.gov (United States)

    Sentana, I. W. B.; Jawas, N.; Asri, S. A.

    2018-01-01

    Lung nodule is an early indicator of some lung diseases, including lung cancer. In Computed Tomography (CT) based image, nodule is known as a shape that appears brighter than lung surrounding. This research aim to develop an application that automatically detect lung nodule in CT images. There are some steps in algorithm such as image acquisition and conversion, image binarization, lung segmentation, blob detection, and classification. Data acquisition is a step to taking image slice by slice from the original *.dicom format and then each image slices is converted into *.tif image format. Binarization that tailoring Otsu algorithm, than separated the background and foreground part of each image slices. After removing the background part, the next step is to segment part of the lung only so the nodule can localized easier. Once again Otsu algorithm is use to detect nodule blob in localized lung area. The final step is tailoring Support Vector Machine (SVM) to classify the nodule. The application has succeed detecting near round nodule with a certain threshold of size. Those detecting result shows drawback in part of thresholding size and shape of nodule that need to enhance in the next part of the research. The algorithm also cannot detect nodule that attached to wall and Lung Chanel, since it depend the searching only on colour differences.

  16. Adaptive slices for acquisition of anisotropic BRDF

    Czech Academy of Sciences Publication Activity Database

    Vávra, Radomír; Filip, Jiří

    (2018) ISSN 2096-0433 R&D Projects: GA ČR GA17-18407S Institutional support: RVO:67985556 Keywords : anisotropic BRDF * slice * sampling Subject RIV: BD - Theory of Information http://library.utia.cas.cz/separaty/2018/RO/vavra-0486116.pdf

  17. Experimental Setups for Single Event Effect Studies

    OpenAIRE

    N. H. Medina; V. A. P. Aguiar; N. Added; F. Aguirre; E. L. A. Macchione; S. G. Alberton; M. A. G. Silveira; J. Benfica; F. Vargas; B. Porcher

    2016-01-01

    Experimental setups are being prepared to test and to qualify electronic devices regarding their tolerance to Single Event Effect (SEE). A multiple test setup and a new beam line developed especially for SEE studies at the São Paulo 8 UD Pelletron accelerator were prepared. This accelerator produces proton beams and heavy ion beams up to 107Ag. A Super conducting Linear accelerator, which is under construction, may fulfill all of the European Space Agency requirements to qualify electronic...

  18. Shape determinative slice localization for patient-specific masseter modeling using shape-based interpolation

    Energy Technology Data Exchange (ETDEWEB)

    Ng, H.P. [NUS Graduate School for Integrative Sciences and Engineering (Singapore); Biomedical Imaging Lab., Agency for Science Technology and Research (Singapore); Foong, K.W.C. [NUS Graduate School for Integrative Sciences and Engineering (Singapore); Dept. of Preventive Dentistry, National Univ. of Singapore (Singapore); Ong, S.H. [Dept. of Electrical and Computer Engineering, National Univ. of Singapore (Singapore); Div. of Bioengineering, National Univ. of Singapore (Singapore); Liu, J.; Nowinski, W.L. [Biomedical Imaging Lab., Agency for Science Technology and Research (Singapore); Goh, P.S. [Dept. of Diagnostic Radiology, National Univ. of Singapore (Singapore)

    2007-06-15

    The masseter plays a critical role in the mastication system. A hybrid method to shape-based interpolation is used to build the masseter model from magnetic resonance (MR) data sets. The main contribution here is the localizing of determinative slices in the data sets where clinicians are required to perform manual segmentations in order for an accurate model to be built. Shape-based criteria were used to locate the candidates for determinative slices and fuzzy-c-means (FCM) clustering technique was used to establish the determinative slices. Five masseter models were built in our work and the average overlap indices ({kappa}) achieved is 85.2%. This indicates that there is good agreement between the models and the manual contour tracings. In addition, the time taken, as compared to manually segmenting all the slices, is significantly lesser. (orig.)

  19. Shape determinative slice localization for patient-specific masseter modeling using shape-based interpolation

    International Nuclear Information System (INIS)

    Ng, H.P.; Foong, K.W.C.; Ong, S.H.; Liu, J.; Nowinski, W.L.; Goh, P.S.

    2007-01-01

    The masseter plays a critical role in the mastication system. A hybrid method to shape-based interpolation is used to build the masseter model from magnetic resonance (MR) data sets. The main contribution here is the localizing of determinative slices in the data sets where clinicians are required to perform manual segmentations in order for an accurate model to be built. Shape-based criteria were used to locate the candidates for determinative slices and fuzzy-c-means (FCM) clustering technique was used to establish the determinative slices. Five masseter models were built in our work and the average overlap indices (κ) achieved is 85.2%. This indicates that there is good agreement between the models and the manual contour tracings. In addition, the time taken, as compared to manually segmenting all the slices, is significantly lesser. (orig.)

  20. Organotypic slice cultures containing the preBötzinger complex generate respiratory-like rhythms

    DEFF Research Database (Denmark)

    Phillips, Wiktor S; Herly, Mikkel; Del Negro, Christopher A

    2016-01-01

    containing the preBötzinger complex (preBötC), the core inspiratory rhythm generator of the ventrolateral brainstem. We measured bilateral synchronous network oscillations, using calcium-sensitive fluorescent dyes, in both ventrolateral (presumably the preBötC) and dorsomedial regions of 7-43 days in vitro......Acute brainstem slice preparations in vitro have advanced understanding of the cellular and synaptic mechanisms of respiratory rhythm generation, but their inherent limitations preclude long-term manipulation and recording experiments. Here, we developed an organotypic slice culture preparation...... of the brainstem displayed up to 193% faster burst frequency (22.4 ± 8.3 bursts/min) and higher signal amplitude (340%) compared to acute slices. We conclude that preBötC-containing slice cultures retain inspiratory-like rhythmic function and therefore may facilitate lines of experimentation that involve extended...

  1. Evaluation of registration strategies for multi-modality images of rat brain slices

    International Nuclear Information System (INIS)

    Palm, Christoph; Vieten, Andrea; Salber, Dagmar; Pietrzyk, Uwe

    2009-01-01

    In neuroscience, small-animal studies frequently involve dealing with series of images from multiple modalities such as histology and autoradiography. The consistent and bias-free restacking of multi-modality image series is obligatory as a starting point for subsequent non-rigid registration procedures and for quantitative comparisons with positron emission tomography (PET) and other in vivo data. Up to now, consistency between 2D slices without cross validation using an inherent 3D modality is frequently presumed to be close to the true morphology due to the smooth appearance of the contours of anatomical structures. However, in multi-modality stacks consistency is difficult to assess. In this work, consistency is defined in terms of smoothness of neighboring slices within a single modality and between different modalities. Registration bias denotes the distortion of the registered stack in comparison to the true 3D morphology and shape. Based on these metrics, different restacking strategies of multi-modality rat brain slices are experimentally evaluated. Experiments based on MRI-simulated and real dual-tracer autoradiograms reveal a clear bias of the restacked volume despite quantitatively high consistency and qualitatively smooth brain structures. However, different registration strategies yield different inter-consistency metrics. If no genuine 3D modality is available, the use of the so-called SOP (slice-order preferred) or MOSOP (modality-and-slice-order preferred) strategy is recommended.

  2. Imaging by the SSFSE single slice method at different viscosities of bile

    International Nuclear Information System (INIS)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi

    2001-01-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T 2 . However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T 2 value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T 2 value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T 1 - and T 2 -weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T 2 values of the bile samples showing relatively high signal intensities on the T 1 -weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T 1 -weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  3. Virtual endoscopy of the small bowel: phantom study and preliminary clinical results

    International Nuclear Information System (INIS)

    Rogalla, P.; Werner-Rustner, M.; Meiri, N.; Hamm, B.; Huitema, A.; van Est, A.

    1998-01-01

    The purpose of this study was to determine the optimal scanning technique for lesion detection in a small bowel phantom and to evaluate the virtual endoscopy (VE) technique in patients. A small bowel phantom with a fold thickness of 7 mm and length of 115 cm was prepared with nine round lesions (3 x 1 mm, 2 x 2 mm, 2 x 3 mm, 2 x 4 mm). Spiral CT parameters were 7/7/4, 3/5/2, 3/5/1, 1.5/3/1 (slice thickness/table feed/reconstruction interval). VE was done using volume rendering technique with 1 cm distance between images and 120 viewing angle. Two masked readers were asked to determine the number and location of the lesions. Seven patients underwent an abdominal CT during one breathhold after placement of a duodenal tube and filling of the small bowel with methyl cellulose contrast solution. VE images were compared with the axial slices with respect to detectability of pathology. With the 7/7/4 protocol only the 4-mm lesions were visualised with fuzzy contours. The 3/5/2 protocol showed both 4-mm lesions, one 3-mm lesion and one false positive lesion. The 3/5/1 protocol showed both 4-mm and both 3-mm (one uncertain) lesions with improved sharpness, and no false positive lesions. One 2-mm and one 1-mm lesion were additionally seen with the 1.5/3/1 protocol. Path definition was difficult in sharp turns or kinks in the lumen. In all patients, no difference was found between VE and axial slices for bowel pathology; however, axial slices showed 'outside' information that was not included in VE. We conclude that the 3/5/2 protocol may be regarded as an optimal compromise between lesion detection, coverage during one breathhold, and number of reconstructed images in patients; round lesions of 4 mm in diameter can be detected with high certainty. (orig.)

  4. Cryopreservation of Precision-cut Tissue Slices for Application in Drug Metabolism Research

    NARCIS (Netherlands)

    Graaf, Inge Anne Maria de

    2002-01-01

    The research described in this thesis had two important aims. The first was to determine whether tissue slices could be used as an in vitro tool to predict the in vivo metabolism of new drugs. The second aim was to find a manner to store tissue slices for longer time periods by cryopreservation.

  5. Virtual marketing in virtual enterprises

    OpenAIRE

    Ale Ebrahim, Nader; Fattahi, Hamaid Ali; Golnam, Arash

    2008-01-01

    Virtualization caused tremendous evolution in the economics of marketing channels, patterns of physical distribution and the structure of distributors and developed a new concept that is known as virtual marketing (VM). VM combines the powerful technologies of interactive marketing and virtual reality. Virtual enterprise (VE) refers to an organization not having a clear physical locus. In other words, VE is an organization distributed geographically and whose work is coordinated through e...

  6. Virtual Presenters: Towards Interactive Virtual Presentations

    NARCIS (Netherlands)

    Nijholt, Antinus; Cappellini, V.; Hemsley, J.

    2005-01-01

    We discuss having virtual presenters in virtual environments that present information to visitors of these environments. Some current research is surveyed and we will look in particular to our research in the context of a virtual meeting room where a virtual presenter uses speech, gestures, pointing

  7. Velocity slice imaging for dissociative electron attachment

    Science.gov (United States)

    Nandi, Dhananjay; Prabhudesai, Vaibhav S.; Krishnakumar, E.; Chatterjee, A.

    2005-05-01

    A velocity slice imaging method is developed for measuring the angular distribution of fragment negative ions arising from dissociative electron attachment (DEA) to molecules. A low energy pulsed electron gun, a pulsed field ion extraction, and a two-dimensional position sensitive detector consisting of microchannel plates and a wedge-and-strip anode are used for this purpose. Detection and storage of each ion separately for its position and flight time allows analysis of the data offline for any given time slice, without resorting to pulsing the detector bias. The performance of the system is evaluated by measuring the angular distribution of O- from O2 and comparing it with existing data obtained using conventional technique. The capability of this technique in obtaining forward and backward angular distribution data is shown to have helped in resolving one of the existing problems in the electron scattering on O2.

  8. Evaluation of rotational set-up errors in patients with thoracic neoplasms

    International Nuclear Information System (INIS)

    Wang Yanyang; Fu Xiaolong; Xia Bing; Fan Min; Yang Huanjun; Ren Jun; Xu Zhiyong; Jiang Guoliang

    2010-01-01

    Objective: To assess the rotational set-up errors in patients with thoracic neoplasms. Methods: 224 kilovoltage cone-beam computed tomography (KVCBCT) scans from 20 thoracic tumor patients were evaluated retrospectively. All these patients were involved in the research of 'Evaluation of the residual set-up error for online kilovoltage cone-beam CT guided thoracic tumor radiation'. Rotational set-up errors, including pitch, roll and yaw, were calculated by 'aligning the KVCBCT with the planning CT, using the semi-automatic alignment method. Results: The average rotational set-up errors were -0.28 degree ±1.52 degree, 0.21 degree ± 0.91 degree and 0.27 degree ± 0.78 degree in the left-fight, superior-inferior and anterior-posterior axis, respectively. The maximal rotational errors of pitch, roll and yaw were 3.5 degree, 2.7 degree and 2.2 degree, respectively. After correction for translational set-up errors, no statistically significant changes in rotational error were observed. Conclusions: The rotational set-up errors in patients with thoracic neoplasms were all small in magnitude. Rotational errors may not change after the correction for translational set-up errors alone, which should be evaluated in a larger sample future. (authors)

  9. Virtual Worlds for Virtual Organizing

    Science.gov (United States)

    Rhoten, Diana; Lutters, Wayne

    The members and resources of a virtual organization are dispersed across time and space, yet they function as a coherent entity through the use of technologies, networks, and alliances. As virtual organizations proliferate and become increasingly important in society, many may exploit the technical architecture s of virtual worlds, which are the confluence of computer-mediated communication, telepresence, and virtual reality originally created for gaming. A brief socio-technical history describes their early origins and the waves of progress followed by stasis that brought us to the current period of renewed enthusiasm. Examination of contemporary examples demonstrates how three genres of virtual worlds have enabled new arenas for virtual organizing: developer-defined closed worlds, user-modifiable quasi-open worlds, and user-generated open worlds. Among expected future trends are an increase in collaboration born virtually rather than imported from existing organizations, a tension between high-fidelity recreations of the physical world and hyper-stylized imaginations of fantasy worlds, and the growth of specialized worlds optimized for particular sectors, companies, or cultures.

  10. Demonstration of the pulmonary interlobar fissures on multiplanar reformatted images with 64-slices spiral CT

    International Nuclear Information System (INIS)

    Wang Yafei; Chen Yerong; Shan Xiuhong; Tang Zhiyang; Ni Enzhen; Huang Hao; Wu Shuchun

    2009-01-01

    Objective: To determine the optimal orientation and slice thickness of reformatted images to visualize the interlobar fissures on multiplanar reformation (MPR) images and to recommend MPR imaging protocal for visualizing interlobar fissures in clinical practise. Methods: 64-slices CT scans of chest were obtained in 300 patients without pulmonary diseases. Axial, sagittal and coronal images were reformatted at 1, 2, 3, 7 mm slice thickness respectively from the raw volume data. Three experienced radiologists evaluated all of the MPR images in the lung window and compared the differences in visualization of the interlohar fissures among the three reformatted orientations and at the different slice thicknesses with Fisher test and Friedman test. Results: Fissures on sagittal MPR images using 1, 2, 3, and 7 mm reformatted slice thickness appeared as a fine line and the preference value analysis showed the MPR images with a 3 mm reformatted slice thickness is the best for visualizing the interlobar fissure. Compared to the sagittal orientation, the coronal was not as good and the axial was the worst among the three orientations. The coronal images with a 3 mm reformatted slice thickness were slightly inferior to sagittal images. The right horizontal fissures were observed as a fine line in all coronal image in 94.0% (282)of cases and in some of the images in 6.0% (18) of cases, the right oblique fissures were displayed as a fine line in coronal images in 2.3% (7) of cases and in some images in 85.0% (255) of cases, the left oblique fissures were displayed as a fine line in some coronal images in 35.7% (107) of cases and displayed as a coarse line in 64.3% (193) of cases. On axial MPR images using 3 mm reformation slice thickness, the right oblique fissures and the left oblique fissures were displayed as a fine line in some axial images in 79.3% (238) and 81.0% (243) of cases respectively, none of the images showed horizontal fissures as a fine line. There was

  11. Live cell imaging of cytosolic NADH/NAD+ ratio in hepatocytes and liver slices.

    Science.gov (United States)

    Masia, Ricard; McCarty, William J; Lahmann, Carolina; Luther, Jay; Chung, Raymond T; Yarmush, Martin L; Yellen, Gary

    2018-01-01

    Fatty liver disease (FLD), the most common chronic liver disease in the United States, may be caused by alcohol or the metabolic syndrome. Alcohol is oxidized in the cytosol of hepatocytes by alcohol dehydrogenase (ADH), which generates NADH and increases cytosolic NADH/NAD + ratio. The increased ratio may be important for development of FLD, but our ability to examine this question is hindered by methodological limitations. To address this, we used the genetically encoded fluorescent sensor Peredox to obtain dynamic, real-time measurements of cytosolic NADH/NAD + ratio in living hepatocytes. Peredox was expressed in dissociated rat hepatocytes and HepG2 cells by transfection, and in mouse liver slices by tail-vein injection of adeno-associated virus (AAV)-encoded sensor. Under control conditions, hepatocytes and liver slices exhibit a relatively low (oxidized) cytosolic NADH/NAD + ratio as reported by Peredox. The ratio responds rapidly and reversibly to substrates of lactate dehydrogenase (LDH) and sorbitol dehydrogenase (SDH). Ethanol causes a robust dose-dependent increase in cytosolic NADH/NAD + ratio, and this increase is mitigated by the presence of NAD + -generating substrates of LDH or SDH. In contrast to hepatocytes and slices, HepG2 cells exhibit a relatively high (reduced) ratio and show minimal responses to substrates of ADH and SDH. In slices, we show that comparable results are obtained with epifluorescence imaging and two-photon fluorescence lifetime imaging (2p-FLIM). Live cell imaging with Peredox is a promising new approach to investigate cytosolic NADH/NAD + ratio in hepatocytes. Imaging in liver slices is particularly attractive because it allows preservation of liver microanatomy and metabolic zonation of hepatocytes. NEW & NOTEWORTHY We describe and validate a new approach for measuring free cytosolic NADH/NAD + ratio in hepatocytes and liver slices: live cell imaging with the fluorescent biosensor Peredox. This approach yields dynamic, real

  12. Single Machine Multi-product Capacitated Lotsizing with Sequence-dependent Setups

    OpenAIRE

    Almada-Lobo , Bernardo; Klabjan , Diego; Carravilla , Maria Antónia; Oliveira , Jose Fernando

    2007-01-01

    Abstract In production planning in the glass container industry, machine dependent setup times and costs are incurred for switchovers from one product to another. The resulting multi-item capacitated lot sizing problem has sequence-dependent setup times and costs. We present two novel linear mixed integer programming formulations for this problem, incorporating all the necessary features of setup carryovers. The compact formulation has polynomially many constraints, while, on the o...

  13. The current status of the MASHA setup

    Science.gov (United States)

    Vedeneev, V. Yu.; Rodin, A. M.; Krupa, L.; Belozerov, A. V.; Chernysheva, E. V.; Dmitriev, S. N.; Gulyaev, A. V.; Gulyaeva, A. V.; Kamas, D.; Kliman, J.; Komarov, A. B.; Motycak, S.; Novoselov, A. S.; Salamatin, V. S.; Stepantsov, S. V.; Podshibyakin, A. V.; Yukhimchuk, S. A.; Granja, C.; Pospisil, S.

    2017-11-01

    The MASHA setup designed as the mass-separator with the resolving power of about 1700, which allows mass identification of superheavy nuclides is described. The setup uses solid ISOL (Isotope Separation On-Line) method. In the present article the upgrade of some parts of MASHA are described: target box (rotating target + hot catcher), ion source based on electron cyclotron resonance, data acquisition, beam diagnostics and control systems. The upgrade is undertaken in order to increase the total separation efficiency, reduce the separation time, of the installation and working stability and make possible continuous measurements at high beam currents. Ion source efficiency was measured in autonomous regime with using calibrated gas leaks of Kr and Xe injected directly to ion source. Some results of the first experiments for production of radon isotopes using the multi-nucleon transfer reaction 48Ca+242Pu are described in the present article. The using of TIMEPIX detector with MASHA setup for neutron-rich Rn isotopes identification is also described.

  14. The current status of the MASHA setup

    International Nuclear Information System (INIS)

    Vedeneev, V. Yu.; Rodin, A. M.; Krupa, L.; Belozerov, A. V.; Chernysheva, E. V.; Dmitriev, S. N.; Gulyaev, A. V.; Gulyaeva, A. V.; Kamas, D.; Kliman, J.; Komarov, A. B.; Motycak, S.; Novoselov, A. S.; Salamatin, V. S.; Stepantsov, S. V.; Podshibyakin, A. V.; Yukhimchuk, S. A.; Granja, C.; Pospisil, S.

    2017-01-01

    The MASHA setup designed as the mass-separator with the resolving power of about 1700, which allows mass identification of superheavy nuclides is described. The setup uses solid ISOL (Isotope Separation On-Line) method. In the present article the upgrade of some parts of MASHA are described: target box (rotating target + hot catcher), ion source based on electron cyclotron resonance, data acquisition, beam diagnostics and control systems. The upgrade is undertaken in order to increase the total separation efficiency, reduce the separation time, of the installation and working stability and make possible continuous measurements at high beam currents. Ion source efficiency was measured in autonomous regime with using calibrated gas leaks of Kr and Xe injected directly to ion source. Some results of the first experiments for production of radon isotopes using the multi-nucleon transfer reaction "4"8Ca+"2"4"2Pu are described in the present article. The using of TIMEPIX detector with MASHA setup for neutron-rich Rn isotopes identification is also described.

  15. The current status of the MASHA setup

    Energy Technology Data Exchange (ETDEWEB)

    Vedeneev, V. Yu., E-mail: vvedeneyev@gmail.com; Rodin, A. M.; Krupa, L.; Belozerov, A. V.; Chernysheva, E. V.; Dmitriev, S. N.; Gulyaev, A. V.; Gulyaeva, A. V.; Kamas, D. [Joint Institute for Nuclear Research, Flerov Laboratory of Nuclear Reactions (Russian Federation); Kliman, J. [Slovak Academy of Sciences, Institute of Physics (Slovakia); Komarov, A. B.; Motycak, S.; Novoselov, A. S.; Salamatin, V. S.; Stepantsov, S. V.; Podshibyakin, A. V.; Yukhimchuk, S. A. [Joint Institute for Nuclear Research, Flerov Laboratory of Nuclear Reactions (Russian Federation); Granja, C.; Pospisil, S. [Czech Technical University in Prague, Institute of Experimental and Applied Physics (Czech Republic)

    2017-11-15

    The MASHA setup designed as the mass-separator with the resolving power of about 1700, which allows mass identification of superheavy nuclides is described. The setup uses solid ISOL (Isotope Separation On-Line) method. In the present article the upgrade of some parts of MASHA are described: target box (rotating target + hot catcher), ion source based on electron cyclotron resonance, data acquisition, beam diagnostics and control systems. The upgrade is undertaken in order to increase the total separation efficiency, reduce the separation time, of the installation and working stability and make possible continuous measurements at high beam currents. Ion source efficiency was measured in autonomous regime with using calibrated gas leaks of Kr and Xe injected directly to ion source. Some results of the first experiments for production of radon isotopes using the multi-nucleon transfer reaction {sup 48}Ca+{sup 242}Pu are described in the present article. The using of TIMEPIX detector with MASHA setup for neutron-rich Rn isotopes identification is also described.

  16. Analysis of aliasing artifacts in 16-slice helical CT

    International Nuclear Information System (INIS)

    Chen Wei; Liu Jingkang; Ou Xiaoguang; Li Wenzheng; Liao Weihua; Yan Ang

    2006-01-01

    Objective: To recognize the features of aliasing artifacts on CT images, and to investigate the effects of imaging parameters on the magnitude of this artifacts. Methods: An adult dry skull was placed in a plastic water-filled container and scanned with a PHILIPS 16-slice helical CT. All the acquired transaxial images by using several different acquisition or reconstruction parameters were examined for comparative assessment of the aliasing artifacts. Results: The aliasing artifacts could be seen in most instances and characterized as the spokewise patterns emanating from the edges of high contrast structure as its radius varies sharply in the longitudinal direction. The images that scanned with pitch of 0.3, 0.6 and 0.9, respectively, showed aliasing artifacts, and its severities increased with pitches escalated (detector combination 16 x 1.5, reconstruction thickness 2 mm); There were more significant aliasing artifacts on the images reconstructed with 0.8 mm slice width compared with 1-mm slice width, and no aliasing artifacts were observed on the images reconstructed with 2-mm slice width (detector combination 16 x 0.75, pitch 0.6); No artifacts were perceived on the images scanned with detector combination 16 x 0.75, while presented evidently with the use of detector combination 16 x 1.5 (pitch 0.6, reconstruction thickness 2 mm); The degrees of aliasing artifacts were unaltered when reconstruction interval and tube current changed. Conclusions: Aliasing artifacts are caused by undersampling. When the operator choose the thinner sampling thickness, lower pitch and a much wider reconstruction thickness judiciously, aliasing artifacts could be effectively mitigated or suppressed. (authors)

  17. Influence of image slice thickness on rectal dose-response relationships following radiotherapy of prostate cancer

    Science.gov (United States)

    Olsson, C.; Thor, M.; Liu, M.; Moissenko, V.; Petersen, S. E.; Høyer, M.; Apte, A.; Deasy, J. O.

    2014-07-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose-response relationships. We investigated this for rectal bleeding using dose-volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman-Kutcher-Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose-response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice thickness

  18. Impact of whey protein coating incorporated with Bifidobacterium and Lactobacillus on sliced ham properties.

    Science.gov (United States)

    Odila Pereira, Joana; Soares, José; J P Monteiro, Maria; Gomes, Ana; Pintado, Manuela

    2018-05-01

    Edible coatings/films with functional ingredients may be a solution to consumers' demands for high-quality food products and an extended shelf-life. The aim of this work was to evaluate the antimicrobial efficiency of edible coatings incorporated with probiotics on sliced ham preservation. Coatings was developed based on whey protein isolates with incorporation of Bifidobacterium animalis Bb-12® or Lactobacillus casei-01. The physicochemical analyses showed that coating decreased water and weight loss on the ham. Furthermore, color analysis showed that coated sliced ham, exhibited no color change, comparatively to uncoated slices. The edible coatings incorporating the probiotic strains inhibited detectable growth of Staphylococcus spp., Pseudomonas spp., Enterobacteriaceae and yeasts/molds, at least, for 45days of storage at 4°C. The sensory evaluation demonstrated that there was a preference for the sliced coated ham. Probiotic bacteria viable cell numbers were maintained at ca. 10 8 CFU/g throughout storage time, enabling the slice of ham to act as a suitable carrier for the beneficial bacteria. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  20. Adaptation of Microplate-based Respirometry for Hippocampal Slices and Analysis of Respiratory Capacity

    Science.gov (United States)

    Schuh, Rosemary A.; Clerc, Pascaline; Hwang, Hyehyun; Mehrabian, Zara; Bittman, Kevin; Chen, Hegang; Polster, Brian M.

    2011-01-01

    Multiple neurodegenerative disorders are associated with altered mitochondrial bioenergetics. Although mitochondrial O2 consumption is frequently measured in isolated mitochondria, isolated synaptic nerve terminals (synaptosomes), or cultured cells, the absence of mature brain circuitry is a remaining limitation. Here we describe the development of a method that adapts the Seahorse Extracellular Flux Analyzer (XF24) for the microplate-based measurement of hippocampal slice O2 consumption. As a first evaluation of the technique, we compared whole slice bioenergetics to previous measurements made with synaptosomes or cultured neurons. We found that mitochondrial respiratory capacity and O2 consumption coupled to ATP synthesis could be estimated in cultured or acute hippocampal slices with preserved neural architecture. Mouse organotypic hippocampal slices oxidizing glucose displayed mitochondrial O2 consumption that was well-coupled, as determined by the sensitivity to the ATP synthase inhibitor oligomycin. However stimulation of respiration by uncoupler was modest (<120% of basal respiration) compared to previous measurements in cells or synaptosomes, although enhanced slightly (to ~150% of basal respiration) by the acute addition of the mitochondrial complex I-linked substrate pyruvate. These findings suggest a high basal utilization of respiratory capacity in slices and a limitation of glucose-derived substrate for maximal respiration. The improved throughput of microplate-based hippocampal respirometry over traditional O2 electrode-based methods is conducive to neuroprotective drug screening. When coupled with cell type-specific pharmacology or genetic manipulations, the ability to efficiently measure O2 consumption from whole slices should advance our understanding of mitochondrial roles in physiology and neuropathology. PMID:21520220

  1. Slicing Method for curved façade and window extraction from point clouds

    Science.gov (United States)

    Iman Zolanvari, S. M.; Laefer, Debra F.

    2016-09-01

    Laser scanning technology is a fast and reliable method to survey structures. However, the automatic conversion of such data into solid models for computation remains a major challenge, especially where non-rectilinear features are present. Since, openings and the overall dimensions of the buildings are the most critical elements in computational models for structural analysis, this article introduces the Slicing Method as a new, computationally-efficient method for extracting overall façade and window boundary points for reconstructing a façade into a geometry compatible for computational modelling. After finding a principal plane, the technique slices a façade into limited portions, with each slice representing a unique, imaginary section passing through a building. This is done along a façade's principal axes to segregate window and door openings from structural portions of the load-bearing masonry walls. The method detects each opening area's boundaries, as well as the overall boundary of the façade, in part, by using a one-dimensional projection to accelerate processing. Slices were optimised as 14.3 slices per vertical metre of building and 25 slices per horizontal metre of building, irrespective of building configuration or complexity. The proposed procedure was validated by its application to three highly decorative, historic brick buildings. Accuracy in excess of 93% was achieved with no manual intervention on highly complex buildings and nearly 100% on simple ones. Furthermore, computational times were less than 3 sec for data sets up to 2.6 million points, while similar existing approaches required more than 16 hr for such datasets.

  2. Reduction of acrylamide formation in potato slices during frying

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Kaack, K.; Granby, Kit

    2004-01-01

    and 40 min; 90degreesC for 2 and 9 min); (iii) immersed in citric acid solutions of different concentrations (10 and 20 g/l) for half an hour. Glucose and asparagine concentration was determined in potato slices before frying, whereas acrylamide content was determined in the resultant fried potato chips...... on average 76% and 68% of the glucose and asparagine content compared to the control. Potato slices blanched at 50degreesC for 70 min surprisingly had a very low acrylamide content (28 mum/kg) even when they were fried at 190degreesC. Potato immersion in citric acid solutions of 10 and 20 g/l reduced...

  3. HUMAN LIVER SLICES EXPRESS THE SAME LIDOCAINE BIOTRANSFORMATION RATE AS ISOLATED HUMAN HEPATOCYTES

    NARCIS (Netherlands)

    OLINGA, P; MEIJER, DKF; SLOOFF, MJH; GROOTHUIS, GMM; Merema, M.T.

    1993-01-01

    In order to investigate whether liver slices are a valuable tool for the assessment of drug metabolism in human liver, we compared the phase I metabolism of lidocaine in human liver slices and hepatocytes prepared from three human livers. Lidocaine is mainly metabolised to monoethylglycinexylidide

  4. New attacks on Wi-Fi Protected Setup

    OpenAIRE

    Hamed Mohtadi; Alireza Rahimi

    2015-01-01

    Wi-Fi Protected Setup (WPS) is a network security standard that is used to secure networks in home and office, introduced in 2006 by the Wi-Fi Alliance. It provides easier configuration setup and is used in almost all recent Wi-Fi devices. In this paper we propose two attacks on this standard. The first attack is an offline brute force attack that uses imbalance on registration protocol. This attack needs user action, but it is more efficient than previous attacks. The second attack uses weak...

  5. An experimental set-up to test heat-moisture exchangers

    NARCIS (Netherlands)

    Unal, N.; Pompe, J. C.; Holland, W. P.; Gültuna, I.; Huygen, P. E.; Jabaaij, K.; Ince, C.; Saygin, B.; Bruining, H. A.

    1995-01-01

    The purpose of this study was to build an experimental set-up to assess continuously the humidification, heating and resistance properties of heat-moisture exchangers (HMEs) under clinical conditions. The experimental set-up consists of a patient model, measurement systems and a ventilator. Surgical

  6. Does slice thickness affect diagnostic performance of 64-slice CT coronary angiography in stable and unstable angina patients with a positive calcium score?

    Energy Technology Data Exchange (ETDEWEB)

    Meijs, Matthijs F.L.; Vos, Alexander M. de; Cramer, Maarten J.; Doevendans, Pieter A.; Vries, Jan J.J. de; Rutten, Annemarieke; Budde, Ricardo P.J.; Prokop, Mathias (Dept. of Radiology, Univ. Medical Center Utrecht, Utrecht (Netherlands)), e-mail: m.meijs@umcutrecht.nl; Meijboom, W. Bob; Feyter, Pim J. de (Dept. of Cardiology, Erasmus Medical Center, Rotterdam (Netherlands))

    2010-05-15

    Background: Coronary calcification can lead to over-estimation of the degree of coronary stenosis. Purpose: To evaluate whether thinner reconstruction thickness improves the diagnostic performance of 64-slice CT coronary angiography (CTCA) in angina patients with a positive calcium score. Material and Methods: We selected 20 scans from a clinical study comparing CTCA to conventional coronary angiography (CCA) in stable and unstable angina patients based on a low number of motion artifacts and a positive calcium score. All images were acquired at 64 x 0.625 mm and each CTCA scan was reconstructed at slice thickness/increment 0.67 mm/0.33 mm, 0.9 mm/0.45 mm, and 1.4 mm/0.7 mm. Two reviewers blinded for CCA results independently evaluated the scans for the presence of significant coronary artery disease (CAD) in three randomly composed series, with =2 weeks in between series. The diagnostic performance of CTCA was compared for the different slice thicknesses using a pooled analysis of both reviewers. Significant CAD was defined as >50% diameter narrowing on quantitative CCA. Image noise (standard deviation of CT numbers) was measured in all scans. Inter-observer variability was assessed with kappa. Results: Significant CAD was present in 8% of 304 available segments. Median total Agatston calcium score was 181.8 (interquartile range 34.9-815.6). Sensitivity at 0.67 mm, 0.9 mm, and 1.4 mm slice thickness was 70% (95% confidence interval 57-83%), 74% (62-86%), and 70% (57-83%), respectively. Specificity was 85% (82-88%), 84% (81-87%), and 84% (81-87%), respectively. The positive predictive value was 30 (21-38%), 29 (21-37%), and 28 (20-36%), respectively. The negative predictive value was 97% (95-98%), 97% (96-99%), and 97% (96-99%), respectively. Kappa for inter-observer agreement was 0.56, 0.58, and 0.59. Noise decreased from 32.9 HU at 0.67 mm, to 23.2 HU at 1.4 mm (P<0.001). Conclusion: Diagnostic performance of CTCA in angina patients with a positive calcium score

  7. [Establishment of Schatzker classification digital models of tibial plateau fractures and its application on virtual surgery].

    Science.gov (United States)

    Liu, Yong-gang; Zuo, Li-xin; Pei, Guo-xian; Dai, Ke; Sang, Jing-wei

    2013-08-20

    To explore the establishment of Schatzker classification digital model of tibial plateau fractures and its application in virtual surgery. Proximal tibial of one healthy male volunteer was examined with 64-slice spiral computed tomography (CT). The data were processed by software Mimics 10.01 and a model of proximal tibia was reconstructed. According to the Schatzker classification criteria of tibial plateau fractures, each type of fracture model was simulated.Screen-captures of fracture model were saved from different directions.Each type of fracture model was exported as video mode.Fracture model was imported into FreeForm modeling system.With a force feedback device, a surgeon could conduct virtual fracture operation simulation.Utilizing the GHOST of FreeForm modeling system, the software of virtual cutting, fracture reduction and fixation was developed.With a force feedback device PHANTOM, a surgeon could manipulate virtual surgical instruments and fracture classification model and simulate surgical actions such as assembly of surgical instruments, drilling, implantation of screw, reduction of fracture, bone grafting and fracture fixation, etc. The digital fracture model was intuitive, three-dimensional and realistic and it had excellent visual effect.Fracture could be observed and charted from optional direction and angle.Fracture model could rotate 360 ° in the corresponding video mode. The virtual surgical environment had a strong sense of reality, immersion and telepresence as well as good interaction and force feedback function in the FreeForm modeling system. The user could make the corresponding decisions about surgical method and choice of internal fixation according to the specific type of tibial plateau fracture as well as repeated operational practice in virtual surgery system. The digital fracture model of Schatzker classification is intuitive, three-dimensional, realistic and dynamic. The virtual surgery systems of Schatzker classifications make

  8. A comparative analysis of dynamic grids vs. virtual grids using the A3pviGrid framework.

    Science.gov (United States)

    Shankaranarayanan, Avinas; Amaldas, Christine

    2010-11-01

    With the proliferation of Quad/Multi-core micro-processors in mainstream platforms such as desktops and workstations; a large number of unused CPU cycles can be utilized for running virtual machines (VMs) as dynamic nodes in distributed environments. Grid services and its service oriented business broker now termed cloud computing could deploy image based virtualization platforms enabling agent based resource management and dynamic fault management. In this paper we present an efficient way of utilizing heterogeneous virtual machines on idle desktops as an environment for consumption of high performance grid services. Spurious and exponential increases in the size of the datasets are constant concerns in medical and pharmaceutical industries due to the constant discovery and publication of large sequence databases. Traditional algorithms are not modeled at handing large data sizes under sudden and dynamic changes in the execution environment as previously discussed. This research was undertaken to compare our previous results with running the same test dataset with that of a virtual Grid platform using virtual machines (Virtualization). The implemented architecture, A3pviGrid utilizes game theoretic optimization and agent based team formation (Coalition) algorithms to improve upon scalability with respect to team formation. Due to the dynamic nature of distributed systems (as discussed in our previous work) all interactions were made local within a team transparently. This paper is a proof of concept of an experimental mini-Grid test-bed compared to running the platform on local virtual machines on a local test cluster. This was done to give every agent its own execution platform enabling anonymity and better control of the dynamic environmental parameters. We also analyze performance and scalability of Blast in a multiple virtual node setup and present our findings. This paper is an extension of our previous research on improving the BLAST application framework

  9. In vitro imaging of coronary artery stents: Are there differences between 16- and 64-slice CT scanners?

    International Nuclear Information System (INIS)

    Wolf, Florian; Feuchtner, Gudrun M.; Homolka, Peter; Langenberger, Herbert; Stadler, Alfred; Bader, Till R.; Weber, Michael; Lammer, Johannes; Loewe, Christian

    2008-01-01

    Purpose: To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents. Methods and materials: Twelve different coronary artery stents were placed in the drillings of a combined heart and chest phantom, which was scanned with a 16- and 64-slice CT scanner. Coronal reformations were evaluated for artificial lumen narrowing, intraluminal attenuation values, and false widening of the outer stent diameter as an indicator of artifacts outside the stent. Results: Mean artificial lumen narrowing was not significantly different between the 16- and 64-slice CT scanner (44% versus 39%; p = 0.408). The differences between the Hounsfield Units (HU) measurements inside and outside the stents were significantly lower (p = 0.001) with 64- compared to 16-slice CT. The standard deviation of the HU measurements inside the stents was significantly (p = 0.002) lower with 64- than with 16-slice CT. Artifacts outside the stents were not significantly different between the scanners (p = 0.866). Conclusion: Visualization of the in-stent lumen is improved with 64-slice CT when compared with 16-slice CT as quantified by significantly lesser intraluminal image noise and less artificial rise in intraluminal HU measurement, which is the most important parameter for the evaluation of stent patency in vivo

  10. Imaging by the SSFSE single slice method at different viscosities of bile

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi [Kawasaki Hospital, Kobe (Japan)

    2001-11-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T{sub 2}. However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T{sub 2} value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T{sub 2} value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T{sub 1}- and T{sub 2}-weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T{sub 2} values of the bile samples showing relatively high signal intensities on the T{sub 1}-weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T{sub 1}-weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  11. A study of the minimum number of slices required for quantification of pulmonary emphysema by computed tomography

    International Nuclear Information System (INIS)

    Hitsuda, Yutaka; Igishi, Tadashi; Kawasaki, Yuji

    2000-01-01

    We attempted to determine the minimum number of slices required for quantification of overall emphysema by computed tomography (CT). Forty-nine patients underwent CT scanning with a 15-mm slice interval, and 13 to 18 slices per patient were obtained. The percentage of low attenuation area (LAA%) per slice was measured with a method that we reported on previously, utilizing a CT program and NIH image. The average LAA% values for 1, 2, 3, and 6 slices evenly spaced through the lungs [LAA% (1), LAA% (2), LAA% (3), and LAA% (6)] were compared with those for all slices [LAA% (All)]. The correlation coefficients for LAA% (1), LAA% (2), LAA% (3), and LAA% (6) with LAA% (All) were 0.961, 0.981, 0.993, and 0.997, respectively. Mean differences ±SD were -3.20±4.21%, -2.32±3.00, -0.20±1.84, and -0.16±1.26, respectively. From these results, we concluded that overall emphysema can be quantified by using at least three slices: one each of the upper, middle, and lower lung. (author)

  12. Estimating intratidal nonlinearity of respiratory system mechanics: a model study using the enhanced gliding-SLICE method

    International Nuclear Information System (INIS)

    Schumann, Stefan; Burcza, Boris; Guttmann, Josef; Haberthür, Christoph; Lichtwarck-Aschoff, Michael

    2009-01-01

    In the clinical situation and in most research work, the analysis of respiratory system mechanics is limited to the estimation of single-value compliances during static or quasi-static conditions. In contrast, our SLICE method analyses intratidal nonlinearity under the dynamic conditions of mechanical ventilation by calculating compliance and resistance for six conjoined volume portions (slices) of the pressure–volume loop by multiple linear regression analysis. With the gliding-SLICE method we present a new approach to determine continuous intratidal nonlinear compliance. The performance of the gliding-SLICE method was tested both in computer simulations and in a physical model of the lung, both simulating different intratidal compliance profiles. Compared to the original SLICE method, the gliding-SLICE method resulted in smaller errors when calculating the compliance or pressure course (all p 2 O s L −1 to 0.8 ± 0.3 cmH 2 O s L −1 (mathematical model) and from 7.2 ± 3.9 cmH 2 O s L −1 to 0.4 ± 0.2 cmH 2 O s L −1 (physical model) (all p < 0.001). We conclude that the new gliding-SLICE method allows detailed assessment of intratidal nonlinear respiratory system mechanics without discontinuity error

  13. Organotypic brain slice cultures of adult transgenic P301S mice--a model for tauopathy studies.

    Directory of Open Access Journals (Sweden)

    Agneta Mewes

    Full Text Available BACKGROUND: Organotypic brain slice cultures represent an excellent compromise between single cell cultures and complete animal studies, in this way replacing and reducing the number of animal experiments. Organotypic brain slices are widely applied to model neuronal development and regeneration as well as neuronal pathology concerning stroke, epilepsy and Alzheimer's disease (AD. AD is characterized by two protein alterations, namely tau hyperphosphorylation and excessive amyloid β deposition, both causing microglia and astrocyte activation. Deposits of hyperphosphorylated tau, called neurofibrillary tangles (NFTs, surrounded by activated glia are modeled in transgenic mice, e.g. the tauopathy model P301S. METHODOLOGY/PRINCIPAL FINDINGS: In this study we explore the benefits and limitations of organotypic brain slice cultures made of mature adult transgenic mice as a potential model system for the multifactorial phenotype of AD. First, neonatal (P1 and adult organotypic brain slice cultures from 7- to 10-month-old transgenic P301S mice have been compared with regard to vitality, which was monitored with the lactate dehydrogenase (LDH- and the MTT (3-(4,5-Dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide assays over 15 days. Neonatal slices displayed a constant high vitality level, while the vitality of adult slice cultures decreased significantly upon cultivation. Various preparation and cultivation conditions were tested to augment the vitality of adult slices and improvements were achieved with a reduced slice thickness, a mild hypothermic cultivation temperature and a cultivation CO(2 concentration of 5%. Furthermore, we present a substantial immunohistochemical characterization analyzing the morphology of neurons, astrocytes and microglia in comparison to neonatal tissue. CONCLUSION/SIGNIFICANCE: Until now only adolescent animals with a maximum age of two months have been used to prepare organotypic brain slices. The current study

  14. Virtualisation Devices for Student Learning: Comparison between Desktop-Based (Oculus Rift) and Mobile-Based (Gear VR) Virtual Reality in Medical and Health Science Education

    Science.gov (United States)

    Moro, Christian; Stromberga, Zane; Stirling, Allan

    2017-01-01

    Consumer-grade virtual reality has recently become available for both desktop and mobile platforms and may redefine the way that students learn. However, the decision regarding which device to utilise within a curriculum is unclear. Desktop-based VR has considerably higher setup costs involved, whereas mobile-based VR cannot produce the quality of…

  15. Performance evaluation of a 64-slice CT system with z-flying focal spot.

    Science.gov (United States)

    Flohr, T; Stierstorfer, K; Raupach, R; Ulzheimer, S; Bruder, H

    2004-12-01

    The meanwhile established generation of 16-slice CT systems enables routine sub-millimeter imaging at short breath-hold times. Clinical progress in the development of multidetector row CT (MDCT) technology beyond 16 slices can more likely be expected from further improvement in spatial and temporal resolution rather than from a mere increase in the speed of volume coverage. We present an evaluation of a recently introduced 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany), which uses a periodic motion of the focal spot in longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. This technique acquires 64 overlapping 0.6 mm slices per rotation. The sampling scheme corresponds to that of a 64 x 0.3 mm detector, with the goal of improved longitudinal resolution and reduced spiral artifacts. After an introduction to the detector design, we discuss the basics of z-flying focal spot technology (z-Sharp). We present phantom and specimen scans for performance evaluation. The measured full width at half maximum (FWHM) of the thinnest spiral slice is 0.65 mm. All spiral slice widths are almost independent of the pitch, with deviations of less than 0.1 mm from the nominal value. Using a high-resolution bar pattern phantom (CATPHAN, Phantom Laboratories, Salem, NY), the longitudinal resolution can be demonstrated to be up to 15 lp/cm at the isocenter independent of the pitch, corresponding to a bar diameter of 0.33 mm. Longitudinal resolution is only slightly degraded for off-center locations. At a distance of 100 mm from the isocenter, 14 lp/cm can be resolved in the z-direction, corresponding to a bar diameter of 0.36 mm. Spiral "windmill" artifacts presenting as hyper- and hypodense structures around osseous edges are effectively reduced by the z-flying focal spot technique. Cardiac scanning benefits from the short gantry rotation time of 0.33 s, providing up to 83 ms temporal resolution with 2-segment ECG

  16. The spectral imaging facility: Setup characterization

    Energy Technology Data Exchange (ETDEWEB)

    De Angelis, Simone, E-mail: simone.deangelis@iaps.inaf.it; De Sanctis, Maria Cristina; Manzari, Paola Olga [Institute for Space Astrophysics and Planetology, INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome (Italy); Ammannito, Eleonora [Institute for Space Astrophysics and Planetology, INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome (Italy); Department of Earth, Planetary and Space Sciences, University of California, Los Angeles, Los Angeles, California 90095-1567 (United States); Di Iorio, Tatiana [ENEA, UTMEA-TER, Rome (Italy); Liberati, Fabrizio [Opto Service SrL, Campagnano di Roma (RM) (Italy); Tarchi, Fabio; Dami, Michele; Olivieri, Monica; Pompei, Carlo [Selex ES, Campi Bisenzio (Italy); Mugnuolo, Raffaele [Italian Space Agency, ASI, Spatial Geodesy Center, Matera (Italy)

    2015-09-15

    The SPectral IMager (SPIM) facility is a laboratory visible infrared spectrometer developed to support space borne observations of rocky bodies of the solar system. Currently, this laboratory setup is used to support the DAWN mission, which is in its journey towards the asteroid 1-Ceres, and to support the 2018 Exo-Mars mission in the spectral investigation of the Martian subsurface. The main part of this setup is an imaging spectrometer that is a spare of the DAWN visible infrared spectrometer. The spectrometer has been assembled and calibrated at Selex ES and then installed in the facility developed at the INAF-IAPS laboratory in Rome. The goal of SPIM is to collect data to build spectral libraries for the interpretation of the space borne and in situ hyperspectral measurements of planetary materials. Given its very high spatial resolution combined with the imaging capability, this instrument can also help in the detailed study of minerals and rocks. In this paper, the instrument setup is first described, and then a series of test measurements, aimed to the characterization of the main subsystems, are reported. In particular, laboratory tests have been performed concerning (i) the radiation sources, (ii) the reference targets, and (iii) linearity of detector response; the instrumental imaging artifacts have also been investigated.

  17. Thin-Slice Measurement of Wisdom

    Directory of Open Access Journals (Sweden)

    Chao S. Hu

    2017-08-01

    Full Text Available Objective Measurement of Wisdom within a short period of time is vital for both the public interest (e.g., understanding a presidential election and research (e.g., testing factors that facilitate wisdom development. A measurement of emotion associated with wisdom would be especially informative; therefore, a novel Thin-Slice measurement of wisdom was developed based on the Berlin Paradigm. For about 2 min, participants imagined the lens of a camera as the eyes of their friend/teacher whom they advised about a life dilemma. Verbal response and facial expression were both recorded by a camera: verbal responses were then rated on both the Berlin Wisdom criteria and newly developed Chinese wisdom criteria; facial expressions were analyzed by the software iMotion FACET module. Results showed acceptable inter-rater and inter-item reliability for this novel paradigm. Moreover, both wisdom ratings were not significantly correlated with Social desirability, and the Berlin wisdom rating was significantly negatively correlated with Neuroticism; feeling of surprise was significantly positively correlated with both wisdom criteria ratings. Our results provide the first evidence of this Thin-slice Wisdom Paradigm’s reliability, its immunity to social desirability, and its validity for assessing candidates’ wisdom within a short timeframe. Although still awaiting further development, this novel Paradigm contributes to an emerging Universal Wisdom Paradigm applicable across cultures.

  18. User Guide: How to Use and Operate Virtual Reality Equipment in the Systems Assessment and Usability Laboratory (SAUL) for Conducting Demonstrations

    Science.gov (United States)

    2017-08-01

    Assessment and Usability Laboratory (SAUL) for Conducting Demonstrations by Michael N Geuss and Joseph A Campanelli Human Research and...Master unable to communicate with necessary computers .... 15 Fig. 14 PPT Studio N setup for 4 users...to communicate with each other and display the same virtual environment to multiple users. Cluster Master must be run on the computer running the

  19. Automatic slice identification in 3D medical images with a ConvNet regressor

    NARCIS (Netherlands)

    de Vos, Bob D.; Viergever, Max A.; de Jong, Pim A.; Išgum, Ivana

    2016-01-01

    Identification of anatomical regions of interest is a prerequisite in many medical image analysis tasks. We propose a method that automatically identifies a slice of interest (SOI) in 3D images with a convolutional neural network (ConvNet) regressor. In 150 chest CT scans two reference slices were

  20. Impact of different setup approaches in image-guided radiotherapy as primary treatment for prostate cancer. A study of 2940 setup deviations in 980 MVCTs

    International Nuclear Information System (INIS)

    Schiller, Kilian; Specht, Hanno; Kampfer, Severin; Duma, Marciana Nona; Petrucci, Alessia; Geinitz, Hans; Schuster, Tibor

    2014-01-01

    The goal of this study was to assess the impact of different setup approaches in image-guided radiotherapy (IMRT) of the prostatic gland. In all, 28 patients with prostate cancer were enrolled in this study. After the placement of an endorectal balloon, the planning target volume (PTV) was treated to a dose of 70 Gy in 35 fractions. A simultaneously integrated boost (SIB) of 76 Gy (2.17 Gy per fraction and per day) was delivered to a smaller target volume. All patients underwent daily prostate-aligned IGRT by megavoltage CT (MVCT). Retrospectively, three different setup approaches were evaluated by comparison to the prostate alignment: setup by skin alignment, endorectal balloon alignment, and automatic registration by bones. A total of 2,940 setup deviations were analyzed in 980 fractions. Compared to prostate alignment, skin mark alignment was associated with substantial displacements, which were ≥ 8 mm in 13 %, 5 %, and 44 % of all fractions in the lateral, longitudinal, and vertical directions, respectively. Endorectal balloon alignment yielded displacements ≥ 8 mm in 3 %, 19 %, and 1 % of all setups; and ≥ 3 mm in 27 %, 58 %, and 18 % of all fractions, respectively. For bone matching, the values were 1 %, 1 %, and 2 % and 3 %, 11 %, and 34 %, respectively. For prostate radiotherapy, setup by skin marks alone is inappropriate for patient positioning due to the fact that, during almost half of the fractions, parts of the prostate would not be targeted successfully with an 8-mm safety margin. Bone matching performs better but not sufficiently for safety margins ≤ 3 mm. Endorectal balloon matching can be combined with bone alignment to increase accuracy in the vertical direction when prostate-based setup is not available. Daily prostate alignment remains the gold standard for high-precision radiotherapy with small safety margins. (orig.) [de

  1. Highly immersive virtual reality laparoscopy simulation: development and future aspects.

    Science.gov (United States)

    Huber, Tobias; Wunderling, Tom; Paschold, Markus; Lang, Hauke; Kneist, Werner; Hansen, Christian

    2018-02-01

    Virtual reality (VR) applications with head-mounted displays (HMDs) have had an impact on information and multimedia technologies. The current work aimed to describe the process of developing a highly immersive VR simulation for laparoscopic surgery. We combined a VR laparoscopy simulator (LapSim) and a VR-HMD to create a user-friendly VR simulation scenario. Continuous clinical feedback was an essential aspect of the development process. We created an artificial VR (AVR) scenario by integrating the simulator video output with VR game components of figures and equipment in an operating room. We also created a highly immersive VR surrounding (IVR) by integrating the simulator video output with a [Formula: see text] video of a standard laparoscopy scenario in the department's operating room. Clinical feedback led to optimization of the visualization, synchronization, and resolution of the virtual operating rooms (in both the IVR and the AVR). Preliminary testing results revealed that individuals experienced a high degree of exhilaration and presence, with rare events of motion sickness. The technical performance showed no significant difference compared to that achieved with the standard LapSim. Our results provided a proof of concept for the technical feasibility of an custom highly immersive VR-HMD setup. Future technical research is needed to improve the visualization, immersion, and capability of interacting within the virtual scenario.

  2. Fluidized bed drying characteristics and modeling of ginger ( zingiber officinale) slices

    Science.gov (United States)

    Parlak, Nezaket

    2015-08-01

    In this study fluidized bed drying characteristics of ginger have been investigated. The effects of the fluidizing air temperature, velocity, humidity and bed height on the drying performance of ginger slices have been found. The experimental moisture loss data of ginger slices has been fitted to the eight thin layer drying models. Two-term model drying model has shown a better fit to the experimental data with R2 of 0.998 as compared to others.

  3. Sensorial Virtualization: Coupling Gaming and Virtual Environment

    NARCIS (Netherlands)

    Garbaya, S.; Miraoui, C.; Wendrich, Robert E.; Lim, T.; Stanescu, I.A.; Hauge, J.B.

    2014-01-01

    Virtual reality and virtualization are currently used to design complex systems and demonstrate that they represent the functionalities of real systems. However, the design refinement of the virtual environment (VE) and distributed virtual environment (DVE) are still time consuming and costly, as it

  4. Lipopolysaccharide does not alter small airway reactivity in mouse lung slices.

    Science.gov (United States)

    Donovan, Chantal; Royce, Simon G; Vlahos, Ross; Bourke, Jane E

    2015-01-01

    The bacterial endotoxin, lipopolysaccharide (LPS) has been associated with occupational airway diseases with asthma-like symptoms and in acute exacerbations of COPD. The direct and indirect effects of LPS on small airway reactivity have not been fully elucidated. We tested the hypothesis that both in vitro and in vivo LPS treatment would increase contraction and impair relaxation of mouse small airways. Lung slices were prepared from naïve Balb/C mice and cultured in the absence or presence of LPS (10 μg/ml) for up to 48 h for measurement of TNFα levels in conditioned media. Alternatively, mice were challenged with PBS or LPS in vivo once a day for 4 days for preparation of lung slices or for harvest of lungs for Q-PCR analysis of gene expression of pro-inflammatory cytokines and receptors involved in airway contraction. Reactivity of small airways to contractile agonists, methacholine and serotonin, and bronchodilator agents, salbutamol, isoprenaline and rosiglitazone, were assessed using phase-contrast microscopy. In vitro LPS treatment of slices increased TNFα release 6-fold but did not alter contraction or relaxation to any agonists tested. In vivo LPS treatment increased lung gene expression of TNFα, IL-1β and ryanodine receptor isoform 2 more than 5-fold. However there were no changes in reactivity in lung slices from these mice, even when also incubated with LPS ex vivo. Despite evidence of LPS-induced inflammation, neither airway hyperresponsiveness or impaired dilator reactivity were evident. The increase in ryanodine receptor isoform 2, known to regulate calcium signaling in vascular smooth muscle, warrants investigation. Since LPS failed to elicit changes in small airway reactivity in mouse lung slices following in vitro or in vivo treatment, alternative approaches are required to define the potential contribution of this endotoxin to altered small airway reactivity in human lung diseases.

  5. Lipopolysaccharide does not alter small airway reactivity in mouse lung slices.

    Directory of Open Access Journals (Sweden)

    Chantal Donovan

    Full Text Available The bacterial endotoxin, lipopolysaccharide (LPS has been associated with occupational airway diseases with asthma-like symptoms and in acute exacerbations of COPD. The direct and indirect effects of LPS on small airway reactivity have not been fully elucidated. We tested the hypothesis that both in vitro and in vivo LPS treatment would increase contraction and impair relaxation of mouse small airways. Lung slices were prepared from naïve Balb/C mice and cultured in the absence or presence of LPS (10 μg/ml for up to 48 h for measurement of TNFα levels in conditioned media. Alternatively, mice were challenged with PBS or LPS in vivo once a day for 4 days for preparation of lung slices or for harvest of lungs for Q-PCR analysis of gene expression of pro-inflammatory cytokines and receptors involved in airway contraction. Reactivity of small airways to contractile agonists, methacholine and serotonin, and bronchodilator agents, salbutamol, isoprenaline and rosiglitazone, were assessed using phase-contrast microscopy. In vitro LPS treatment of slices increased TNFα release 6-fold but did not alter contraction or relaxation to any agonists tested. In vivo LPS treatment increased lung gene expression of TNFα, IL-1β and ryanodine receptor isoform 2 more than 5-fold. However there were no changes in reactivity in lung slices from these mice, even when also incubated with LPS ex vivo. Despite evidence of LPS-induced inflammation, neither airway hyperresponsiveness or impaired dilator reactivity were evident. The increase in ryanodine receptor isoform 2, known to regulate calcium signaling in vascular smooth muscle, warrants investigation. Since LPS failed to elicit changes in small airway reactivity in mouse lung slices following in vitro or in vivo treatment, alternative approaches are required to define the potential contribution of this endotoxin to altered small airway reactivity in human lung diseases.

  6. Measures of large-scale structure in the CfA redshift survey slices

    International Nuclear Information System (INIS)

    De Lapparent, V.; Geller, M.J.; Huchra, J.P.

    1991-01-01

    Variations of the counts-in-cells with cell size are used here to define two statistical measures of large-scale clustering in three 6 deg slices of the CfA redshift survey. A percolation criterion is used to estimate the filling factor which measures the fraction of the total volume in the survey occupied by the large-scale structures. For the full 18 deg slice of the CfA redshift survey, f is about 0.25 + or - 0.05. After removing groups with more than five members from two of the slices, variations of the counts in occupied cells with cell size have a power-law behavior with a slope beta about 2.2 on scales from 1-10/h Mpc. Application of both this statistic and the percolation analysis to simulations suggests that a network of two-dimensional structures is a better description of the geometry of the clustering in the CfA slices than a network of one-dimensional structures. Counts-in-cells are also used to estimate at 0.3 galaxy h-squared/Mpc the average galaxy surface density in sheets like the Great Wall. 46 refs

  7. The physiology of rodent beta-cells in pancreas slices.

    Science.gov (United States)

    Rupnik, M

    2009-01-01

    Beta-cells in pancreatic islets form complex syncytia. Sufficient cell-to-cell electrical coupling seems to ensure coordinated depolarization pattern and insulin release that can be further modulated by rich innervation. The complex structure and coordinated action develop after birth during fast proliferation of the endocrine tissue. These emergent properties can be lost due to various reasons later in life and can lead to glucose intolerance and diabetes mellitus. Pancreas slice is a novel method of choice to study the physiology of beta-cells still embedded in their normal cellulo-social context. I present major advantages, list drawbacks and provide an overview on recent advances in our understanding of the physiology of beta-cells using the pancreas slice approach.

  8. Mis-estimation and bias of hyperpolarized apparent diffusion coefficient measurements due to slice profile effects.

    Science.gov (United States)

    Gordon, Jeremy W; Milshteyn, Eugene; Marco-Rius, Irene; Ohliger, Michael; Vigneron, Daniel B; Larson, Peder E Z

    2017-09-01

    The purpose of this work was to explore the impact of slice profile effects on apparent diffusion coefficient (ADC) mapping of hyperpolarized (HP) substrates. Slice profile effects were simulated using a Gaussian radiofrequency (RF) pulse with a variety of flip angle schedules and b-value ordering schemes. A long T 1 water phantom was used to validate the simulation results, and ADC mapping of HP [ 13 C, 15 N 2 ]urea was performed on the murine liver to assess these effects in vivo. Slice profile effects result in excess signal after repeated RF pulses, causing bias in HP measurements. The largest error occurs for metabolites with small ADCs, resulting in up to 10-fold overestimation for metabolites that are in more-restricted environments. A mixed b-value scheme substantially reduces this bias, whereas scaling the slice-select gradient can mitigate it completely. In vivo, the liver ADC of hyperpolarized [ 13 C, 15 N 2 ]urea is nearly 70% lower (0.99 ± 0.22 vs 1.69 ± 0.21 × 10 -3 mm 2 /s) when slice-select gradient scaling is used. Slice profile effects can lead to bias in HP ADC measurements. A mixed b-value ordering scheme can reduce this bias compared to sequential b-value ordering. Slice-select gradient scaling can also correct for this deviation, minimizing bias and providing more-precise ADC measurements of HP substrates. Magn Reson Med 78:1087-1092, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Effect of simultaneous infrared dry-blanching and dehydration on quality characteristics of carrot slices

    Science.gov (United States)

    This study investigated the effects of various processing parameters on carrot slices exposed to infrared (IR) radiation heating for achieving simultaneous infrared dry-blanching and dehydration (SIRDBD). The investigated parameters were product surface temperature, slice thickness and processing ti...

  10. Mathematical modeling of hot air/electrohydrodynamic (EHD) drying kinetics of mushroom slices

    International Nuclear Information System (INIS)

    Taghian Dinani, Somayeh; Hamdami, Nasser; Shahedi, Mohammad; Havet, Michel

    2014-01-01

    Highlights: • Hot air/EHD drying behavior of thin layer mushroom slices was evaluated. • A new empirical model was proposed for drying kinetics modeling of mushroom slices. • The new model presents excellent predictions for hot air/EHD drying of mushroom. - Abstract: Researches about mathematical modeling of electrohydrodynamic (EHD) drying are rare. In this study, hot air combined with electrohydrodynamic (EHD) drying behavior of thin layer mushroom slices was evaluated in a laboratory scale dryer at voltages of 17, 19, and 21 kV and electrode gaps of 5, 6, and 7 cm. The drying curves were fitted to ten different mathematical models (Newton, Page, Modified Page, Henderson and Pabis, Logarithmic, Two-term exponential, Midilli and Kucuk, Wang and Singh, Weibull and Parabolic models) and a proposed new empirical model to select a suitable drying equation for drying mushroom slices in a hot air combined with EHD dryer. Coefficients of the models were determined by non-linear regression analysis and the models were compared based on their coefficient of determination (R 2 ), sum of square errors (SSE) and root mean square error (RMSE) between experimental and predicted moisture ratios. According to the results, the proposed model that contains only three parameters provided the best fit with the experimental data. It was closely followed by the Midilli and Kucuk model that contains four parameters. Therefore, the proposed model can present comfortable usage and excellent predictions for the moisture content changes of mushroom slices in the hot air combined with EHD drying system

  11. Brain Slice Staining and Preparation for Three-Dimensional Super-Resolution Microscopy

    Science.gov (United States)

    German, Christopher L.; Gudheti, Manasa V.; Fleckenstein, Annette E.; Jorgensen, Erik M.

    2018-01-01

    Localization microscopy techniques – such as photoactivation localization microscopy (PALM), fluorescent PALM (FPALM), ground state depletion (GSD), and stochastic optical reconstruction microscopy (STORM) – provide the highest precision for single molecule localization currently available. However, localization microscopy has been largely limited to cell cultures due to the difficulties that arise in imaging thicker tissue sections. Sample fixation and antibody staining, background fluorescence, fluorophore photoinstability, light scattering in thick sections, and sample movement create significant challenges for imaging intact tissue. We have developed a sample preparation and image acquisition protocol to address these challenges in rat brain slices. The sample preparation combined multiple fixation steps, saponin permeabilization, and tissue clarification. Together, these preserve intracellular structures, promote antibody penetration, reduce background fluorescence and light scattering, and allow acquisition of images deep in a 30 μm thick slice. Image acquisition challenges were resolved by overlaying samples with a permeable agarose pad and custom-built stainless steel imaging adapter, and sealing the imaging chamber. This approach kept slices flat, immobile, bathed in imaging buffer, and prevented buffer oxidation during imaging. Using this protocol, we consistently obtained single molecule localizations of synaptic vesicle and active zone proteins in three-dimensions within individual synaptic terminals of the striatum in rat brain slices. These techniques may be easily adapted to the preparation and imaging of other tissues, substantially broadening the application of super-resolution imaging. PMID:28924666

  12. Prolonged life of human acute hippocampal slices from temporal lobe epilepsy surgery

    DEFF Research Database (Denmark)

    Wickham, J; Brödjegård, N G; Vighagen, R

    2018-01-01

    Resected hippocampal tissue from patients with drug-resistant epilepsy presents a unique possibility to test novel treatment strategies directly in target tissue. The post-resection time for testing and analysis however is normally limited. Acute tissue slices allow for electrophysiological...... granule whole-cell recordings, can be consistently induced in these slices, underlying the usefulness of this methodology for testing and/or validating novel treatment strategies for epilepsy....

  13. Virtual Class Support at the Virtual Machine Level

    DEFF Research Database (Denmark)

    Nielsen, Anders Bach; Ernst, Erik

    2009-01-01

    This paper describes how virtual classes can be supported in a virtual machine.  Main-stream virtual machines such as the Java Virtual Machine and the .NET platform dominate the world today, and many languages are being executed on these virtual machines even though their embodied design choices...... conflict with the design choices of the virtual machine.  For instance, there is a non-trivial mismatch between the main-stream virtual machines mentioned above and dynamically typed languages.  One language concept that creates an even greater mismatch is virtual classes, in particular because fully...... general support for virtual classes requires generation of new classes at run-time by mixin composition.  Languages like CaesarJ and ObjectTeams can express virtual classes restricted to the subset that does not require run-time generation of classes, because of the restrictions imposed by the Java...

  14. State-of-the-art on Virtualization and Software Defined Networking for Efficient Resource Allocation on Multi-tenant 5G Networks

    Directory of Open Access Journals (Sweden)

    Tsirakis Christos

    2017-01-01

    Full Text Available Global data traffic explosion is expected to set stringent requirements for next generation networks in the next decades. Besides, very low latencies will have to be guaranteed for enabling new delay critical services. However, current Software Defined Networking (SDN solutions have limitations in terms of separating both data and control planes among tenants/operators, and the capability to adapt to new or changing requirements. Moreover, some virtualization schemes do not ensure isolation of resources and do not guarantee bandwidth across the entities. While some others fail to provide flexibility to the slices to customize the resource allocation across the users. Therefore, novel SDN and virtualization techniques should be implemented to realize the upcoming 5G network that will facilitate at least efficient resource allocation and multi-tenancy among the plethora of different requirements.

  15. A simple Lissajous curves experimental setup

    Science.gov (United States)

    Şahin Kızılcık, Hasan; Damlı, Volkan

    2018-05-01

    The aim of this study is to develop an experimental setup to produce Lissajous curves. The setup was made using a smartphone, a powered speaker (computer speaker), a balloon, a laser pointer and a piece of mirror. Lissajous curves are formed as follows: a piece of mirror is attached to a balloon. The balloon is vibrated with the sound signal provided by the speaker that is connected to a smartphone. The laser beam is reflected off the mirror and the reflection is shaped as a Lissajous curve. Because of the intersection of two frequencies (frequency of the sound signal and natural vibration frequency of the balloon), these curves are formed. They can be used to measure the ratio of frequencies.

  16. Time-space modal logic for verification of bit-slice circuits

    Science.gov (United States)

    Hiraishi, Hiromi

    1996-03-01

    The major goal of this paper is to propose a new modal logic aiming at formal verification of bit-slice circuits. The new logic is called as time-space modal logic and its major feature is that it can handle two transition relations: one for time transition and the other for space transition. As for a verification algorithm, a symbolic model checking algorithm of the new logic is shown. This could be applicable to verification of bit-slice microprocessor of infinite bit width and 1D systolic array of infinite length. A simple benchmark result shows the effectiveness of the proposed approach.

  17. A prospective, randomized study addressing the need for physical simulation following virtual simulation

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; Waterman, Frank M.; Corn, Benjamin W.; Curran, Walter J.

    1997-01-01

    Purpose: To accurately implement a treatment plan obtained by virtual or CT simulation, conventional or physical simulation is still widely used. To evaluate the need for physical simulation, we prospectively randomized patients to undergo physical simulation or no additional simulation after virtual simulation. Methods and Materials: From July 1995 to September 1996, 75 patients underwent conformal four-field radiation therapy planning for prostate cancer with a commercial grade CT simulator. The patients were randomized to undergo either port filming immediately following physical simulation or port filming alone. The precision of implementing the devised plan was evaluated by comparing simulator radiographs and/or port films against the digitally reconstructed radiographs (DRRs) for x, y, and z displacements of the isocenter. Changes in beam aperture were also prospectively evaluated. Results: Thirty-seven patients were randomized to undergo physical simulation and first day port filming, and 38 had first day treatment verification films only without a physical simulation. Seventy-eight simulator radiographs and 195 first day treatment port films were reviewed. There was no statistically significant reduction in treatment setup error (>5 mm) if patients underwent physical simulation following virtual simulation. No patient required a resimulation, and there was no significant difference in changes of beam aperture. Conclusions: Following virtual simulation, physical simulation may not be necessary to accurately implement the conformal four-field technique. Because port filming appears to be sufficient to assure precise and reliable execution of a devised treatment plan, physical simulation may be eliminated from the process of CT based planning when virtual simulation is available

  18. Excitotoxic effects of non-NMDA receptor agonists in organotypic corticostriatal slice cultures

    DEFF Research Database (Denmark)

    Kristensen, B W; Noraberg, J; Jakobsen, B

    1999-01-01

    of the cytosolic enzyme lactate dehydrogenase (LDH) into the culture medium and loss of glutamic acid decarboxylase (GAD) activity in the tissue. Histological sections were also stained by the fluorescent dye Fluoro-Jade (FJ), for degenerating neurons and by immunocytochemical staining for gamma-aminobutyric acid...... density of Fluoro-Jade staining, (3) loss of GAD-activity in tissue homogenates, and (4) loss of GABA-immunostained neurons. We conclude that both differences between compounds (AMPA vs. KA) and brain areas (striatum vs. cortex) can be demonstrated in corticostriatal slice cultures, which in conjunction...... in corticostriatal slice cultures. The purpose was to examine the feasibility of these cultures for excitotoxic studies, and to demonstrate possible differential excitotoxic effects of KA and AMPA on striatal and cortical neurons. Slices of dorsolateral striatum with overlying neocortex were obtained from neonatal...

  19. Setup Time Reduction On Solder Paste Printing Machine – A Case Study

    Directory of Open Access Journals (Sweden)

    Rajesh Dhake

    2013-06-01

    Full Text Available Lean manufacturing envisages the reduction of the seven deadly wastes referred to as MUDA. Setup time forms a major component of the equipment downtime. It leads to lower machine utilization and restricts the output and product variety. This necessitates the requirement for quick setups. Single Minute Exchange of Die philosophy (a lean manufacturing tool here after referred as “SMED” is one of the important tool which aims at quick setups driving smaller lot sizes, lower production costs, improve productivity in terms of increased output, increased utilization of machine and labor hours, make additional capacity available (often at bottleneck resources, reduce scrap and rework, and increase flexibility[3]. This paper focuses on the application of Single Minute Exchange of Die[1] and Quick Changeover Philosophy[2] for reducing setup time on Solder Past Printing Machine (bottleneck machine in a electronic speedo-cluster manufacturing company. The four step SMED philosophy was adopted to effect reduction in setup time. The initial step was gathering information about the present setup times and its proportion to the total productive time. A detailed video based time study of setup activities was done to classify them into external and internal setup activities in terms of their need (i.e. preparation, replacement or adjustment, time taken and the way these could be reduced, simplified or eliminated. The improvements effected were of three categories viz., mechanical, procedural and organizational. The paper concludes by comparing the present and proposed (implemented methods of setup procedures.

  20. Biocompatibility of silicon-based arrays of electrodes coupled to organotypic hippocampal brain slice cultures

    DEFF Research Database (Denmark)

    Kristensen, Bjarne Winther; Noraberg, J; Thiébaud, P

    2001-01-01

    by Nissl staining, Timm sulphide silver-staining, microtubule-associated protein 2 (MAP2) and glial fibrillary acidic protein (GFAP) immunostaining, the slice cultures grown on chips did not differ from conventionally grown slice cultures. Neither were there any signs of astrogliosis or neurodegeneration...

  1. Advanced single-slice rebinning for tilted spiral cone-beam CT

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Fuchs, Theo; Schaller, Stefan; Kalender, Willi A.

    2001-01-01

    Future medical CT scanners and today's micro CT scanners demand cone-beam reconstruction algorithms that are capable of reconstructing data acquired from a tilted spiral trajectory where the vector of rotation is not necessarily parallel to the vector of table increment. For the medical CT scanner this case of nonparallel object motion is met for nonzero gantry tilt: the table moves into a direction that is not perpendicular to the plane of rotation. Since this is not a special application of medical CT but rather a daily routine in head exams, there is a strong need for corresponding reconstruction algorithms. In contrast to medical CT, where the special case of nonperpendicular motion is used on purpose, micro CT scanners cannot avoid aberrations of the rotational axis and the table increment vector due to alignment problems. Especially for those micro CT scanners that have the lifting stage mounted on the rotation table (in contrast to setups where the lifting stage holds the rotation table), this kind of misalignment is equivalent to a gantry tilt. We therefore generalize the advanced single-slice rebinning algorithm (ASSR), which is considered a very promising approach for medical cone-beam reconstruction due to its high image quality and its high reconstruction speed [Med. Phys. 27, 754-772 (2000)], to the case of tilted gantries. We evaluate this extended ASSR approach (which we will denote as ASSR + , for convenience) in comparison to the original ASSR algorithm using simulated phantom data for reconstruction. For the case of nonparallel object motion ASSR + shows significant improvements over ASSR, however, its computational complexity is slightly increased due to the broken symmetry of the spiral trajectory

  2. A brain slice bath for physiology and compound microscopy, with dual-sided perifusion.

    Science.gov (United States)

    Heyward, P M

    2010-12-01

    Contemporary in vitro brain slice studies can employ compound microscopes to identify individual neurons or their processes for physiological recording or imaging. This requires that the bath used to maintain the tissue fits within the working distances of a water-dipping objective and microscope condenser. A common means of achieving this is to maintain thin tissue slices on the glass floor of a recording bath, exposing only one surface of the tissue to oxygenated bathing medium. Emerging evidence suggests that physiology can be compromised by this approach. Flowing medium past both sides of submerged brain slices is optimal, but recording baths utilizing this principle are not readily available for use on compound microscopes. This paper describes a tissue bath designed specifically for microscopy and physiological recording, in which temperature-controlled medium flows past both sides of the slices. A particular feature of this design is the use of concentric mesh rings to support and transport the live tissue without mechanical disturbance. The design is also easily adapted for use with thin acute slices, cultured slices, and acutely dispersed or cultured cells maintained either on cover slips or placed directly on the floor of the bath. The low profile of the bath provides a low angle of approach for electrodes, and allows use of standard condensers, nosepieces and water-dipping objective lenses. If visualization of individual neurons is not required, the bath can be mounted on a simple stand and used with a dissecting microscope. Heating is integral to the bath, and any temperature controller capable of driving a resistive load can be used. The bath is robust, readily constructed and requires minimal maintenance. Full construction and operation details are given. © 2010 The Author Journal of Microscopy © 2010 The Royal Microscopical Society.

  3. Intersection-based registration of slice stacks to form 3D images of the human fetal brain

    DEFF Research Database (Denmark)

    Kim, Kio; Hansen, Mads Fogtmann; Habas, Piotr

    2008-01-01

    Clinical fetal MR imaging of the brain commonly makes use of fast 2D acquisitions of multiple sets of approximately orthogonal 2D slices. We and others have previously proposed an iterative slice-to-volume registration process to recover a geometrically consistent 3D image. However......, these approaches depend on a 3D volume reconstruction step during the slice alignment. This is both computationally expensive and makes the convergence of the registration process poorly defined. In this paper our key contribution is a new approach which considers the collective alignment of all slices directly...... of the approach applied to simulated data and clinically acquired fetal images....

  4. Microsoft Virtualization Master Microsoft Server, Desktop, Application, and Presentation Virtualization

    CERN Document Server

    Olzak, Thomas; Boomer, Jason; Keefer, Robert M

    2010-01-01

    Microsoft Virtualization helps you understand and implement the latest virtualization strategies available with Microsoft products. This book focuses on: Server Virtualization, Desktop Virtualization, Application Virtualization, and Presentation Virtualization. Whether you are managing Hyper-V, implementing desktop virtualization, or even migrating virtual machines, this book is packed with coverage on all aspects of these processes. Written by a talented team of Microsoft MVPs, Microsoft Virtualization is the leading resource for a full installation, migration, or integration of virtual syste

  5. Evaluation of solitary pulmonary metastasis of extrathoracic tumor with thin-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shiotani, Seiji; Yamada, Kouzo; Oshita, Fumihiro; Nomura, Ikuo; Noda, Kazumasa; Yamagata, Tatushi; Tajiri, Michihiko; Ishibashi, Makoto; Kameda, Youichi [Kanagawa Cancer Center, Yokohama (Japan)

    1995-10-01

    Thin-slice computed tomography (CT) images were compared with pathological findings in 9 specimens of solitary pulmonary nodules, which had been pathologically diagnosed as pulmonary metastasis of extrathoracic tumor. The thin-slice CT images were 2 mm-thick images reconstructed using a TCT-900S, HELIX (Toshiba, Tokyo) and examined at two different window and level settings. In every case, the surgical specimens were sliced transversely to correlate with the CT images. According to the image findings, the internal structure was of the solid-density type in every case, and the margin showed spiculation in 22%, notching in 67% and pleural indentation in 89%. Regarding the relationship between the pulmonary vessels and tumors, plural vascular involvement was revealed in every case. Thus, it was difficult to distinguish solitary pulmonary metastasis of extrathoracic tumor from primary lung cancer based on the thin-slice CT images. For some solitary pulmonary metastasis of extrathoracic tumor, a comprehensive diagnostic approach taking both the anamnesis and pathological findings into consideration was required. (author).

  6. Couch height–based patient setup for abdominal radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ohira, Shingo [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita (Japan); Ueda, Yoshihiro [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita (Japan); Nishiyama, Kinji [Department of Radiation Oncology, Yao Municipal Hospital, Yao (Japan); Miyazaki, Masayoshi; Isono, Masaru; Tsujii, Katsutomo [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Takashina, Masaaki; Koizumi, Masahiko [Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita (Japan); Kawanabe, Kiyoto [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Teshima, Teruki, E-mail: teshima-te@mc.pref.osaka.jp [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan)

    2016-04-01

    There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on the computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.

  7. A Novel Approach for Transmission of 56 Gbit/s NRZ Signal in Access Network Using Spectrum Slicing Technique

    DEFF Research Database (Denmark)

    Spolitis, S.; Vegas Olmos, Juan José; Bobrovs, V.

    2013-01-01

    We present the spectrum slicing and stitching concept for high-capacity low optics complexity optical access networks. Spectrum slicing and stitching of a 56 Gbit/s NRZ electrical signal is experimentally demonstrated for the first time.......We present the spectrum slicing and stitching concept for high-capacity low optics complexity optical access networks. Spectrum slicing and stitching of a 56 Gbit/s NRZ electrical signal is experimentally demonstrated for the first time....

  8. Abscisic Acid accumulation in spinach leaf slices in the presence of penetrating and nonpenetrating solutes.

    Science.gov (United States)

    Creelman, R A; Zeevaart, J A

    1985-01-01

    Abscisic acid (ABA) accumulated in detached, wilted leaves of spinach (Spinacia oleracea L. cv Savoy Hybrid 612) and reached a maximum level within 3 to 4 hours. The increase in ABA over that found in detached turgid leaves was approximately 10-fold. The effects of water stress could be mimicked by the use of thin slices of spinach leaves incubated in the presence of 0.6 molar mannitol, a compound which causes plasmolysis (loss of turgor). About equal amounts of ABA were found both in the leaf slices and in detached leaves, whereas 2 to 4 times more ABA accumulated in the medium than in the slices. When spinach leaf slices were incubated with ethylene glycol, a compound which rapidly penetrates the cell membrane causing a decrease in the osmotic potential of the tissue and only transient loss of turgor, no ABA accumulated. Ethylene glycol was not inhibitory with respect to ABA accumulation. Spinach leaf slices incubated in both ethylene glycol and mannitol had ABA levels similar to those found when slices were incubated with mannitol alone. Increases similar to those found with mannitol also occurred when Aquacide III, a highly purified form of polyethylene glycol, was used. Aquacide III causes cytorrhysis, a situation similar to that found in wilted leaves. Thus, it appears that loss of turgor is essential for ABA accumulation.When spinach leaf slices were incubated with solutes which are supposed to disturb membrane integrity (KHSO(3), 2-propanol, or KCl) no increase in ABA was observed. These data indicate that, with respect to the accumulation of ABA, mannitol caused a physical stress (loss of turgor) rather than a chemical stress (membrane damage).

  9. Software framework developed for the slice test of the ATLAS endcap muon trigger system

    CERN Document Server

    Komatsu, S; Ishida, Y; Tanaka, K; Hasuko, K; Kano, H; Matsumoto, Y; Yakamura, Y; Sakamoto, H; Ikeno, M; Nakayoshi, K; Sasaki, O; Yasu, Y; Hasegawa, Y; Totsuka, M; Tsuji, S; Maeno, T; Ichimiya, R; Kurashige, H

    2002-01-01

    A sliced system test of the ATLAS end cap muon level 1 trigger system has been done in 2001 and 2002 separately. We have developed an own software framework for property and run controls for the slice test in 2001. The system is described in C++ throughout. The multi-PC control system is accomplished using the CORBA system. We have then restructured the software system on top of the ATLAS online software framework, and used this one for the slice test in 2002. In this report we discuss two systems in detail with emphasizing the module property configuration and run control. (8 refs).

  10. Virtual Library: An essential component of virtual education

    Directory of Open Access Journals (Sweden)

    M zarghani

    2015-06-01

    Full Text Available Abstract Introduction: Library is one of the essential elements of universities which provide some important educational needs of students. Virtual education can not be exempted and virtual libraries are important support for virtual training programs. The purpose of this study is to evaluate the viewpoint of administrators and students in virtual education centers about the virtual library, its role and resources. Methods: This study was a descriptive survey. The research instrument was a researcher made questionnaire that its validity and reliability was confirmed. The study population consisted of 19 virtual training centers in Tehran city. Out of 19 centers, simple randomized sampling was done in five Centers. The sample size was 360 students. Data collection was conducted online and descriptive statistics using SPSS 18 and Excel software were used. Results: The results showed that viewpoints of administrators and students about the mission and services of virtual libraries in some cases were similar and in some cases were different. One of the administrators’ reasons for setting up a virtual learning system was lifelong learning, and lack of knowledge about virtual libraries was the reason for inadequate use of virtual libraries. The best format of virtual library from the administrators’ and students’ viewpoint, was portal document format (PDF. Conclusion: One of the most important function of a virtual library, is lifelong learning and empowering users to provide information and educational needs. The main reason for not setting up a virtual library is t lack of knowledge about it.

  11. The power of Virtual Globes for valorising cultural heritage and enabling sustainable tourism: NASA World Wind applications

    Science.gov (United States)

    Brovelli, M.; Hogan, P.; Minghini, M.; Zamboni, G.

    2013-10-01

    Inspired by the visionary idea of Digital Earth, as well as from the tremendous improvements in geo-technologies, use of virtual globes has been changing the way people approach to geographic information on the Web. Unlike the traditional 2D-visualization typical of Geographic Information Systems (GIS), virtual globes offer multi-dimensional, fully-realistic content visualization which allows for a much richer user experience. This research investigates the potential for using virtual globes to foster tourism and enhance cultural heritage. The paper first outlines the state of the art for existing virtual globes, pointing out some possible categorizations according to license type, platform-dependence, application type, default layers, functionalities and freedom of customization. Based on this analysis, the NASA World Wind virtual globe is the preferred tool for promoting tourism and cultural heritage. This is because its open source nature allows unlimited customization (in terms of both data and functionalities), and its Java core supports platform-independence. Relevant tourism-oriented World Wind-based applications, dealing with both the Web promotion of historical cartography and the setup of a participatory Web platform exploiting crowd-sourced data, are described. Finally, the paper presents a project focusing on the promotion of the Via Regina area (crossing the border between Italy and Switzerland) through an ad hoc World Wind customization. World Wind can thus be considered an ideal virtual globe for tourism applications, as it can be shaped to increase awareness of cultural history and, in turn, enhance touristic experience.

  12. Evaluation of methylmercury biotransformation using rat liver slices

    Energy Technology Data Exchange (ETDEWEB)

    Yasutake, A. [Biochemistry Section, National Inst. for Minamata Disease, Minamata, Kumamoto (Japan); Hirayama, K. [Kumamoto University College of Medical Science, Kuhonji (Japan)

    2001-09-01

    To examine the demethylation reaction of methylmercury (MeHg) in rat liver, slices prepared from MeHg-treated rats were incubated in L-15 medium under 95% O{sub 2}/5% CO{sub 2} atmosphere. During the incubation, the amount of inorganic Hg in the slices markedly increased in a time-dependent manner, although the concentration of total Hg remained unchanged. Since the C-Hg bond in MeHg was demonstrated to be cleaved by the action of some reactive oxygen species, the effects on MeHg demethylation of several reagents that could modify reactive oxygen production were examined in the present system. Methylviologen was found to be an effective enhancer of the demethylation reaction with only a minor effect on lipid peroxidation. On the other hand, ferrous ion added to the medium showed no effect on demethylation in the presence or absence of methylviologen, although lipid peroxide levels were increased significantly by ferrous ion. Similarly, deferoxamine mesylate, which effectively suppressed the increase in lipid peroxide levels, also had no effect on demethylation. Furthermore, hydroxy radical scavengers, such as mannitol and dimethylsulfoxide, had no effect on inorganic Hg production. Rotenone, an inhibitor of complex I in the mitochondrial electron transport system, increased levels of both inorganic Hg and lipid peroxide. However, other inhibitors, such as antimycin A, myxothiazole and NaCN, significantly suppressed the demethylation reaction. Cell fractionation of the MeHg-treated rat liver revealed that the ratio of inorganic Hg to total Hg was highest in the mitochondrial fraction. Furthermore, superoxide anion could degrade MeHg in an organic solvent but not in water. These results suggested that the demethylation of MeHg by the liver slice would proceed with the aid of superoxide anion produced in the electron transfer system at the hydrophobic mitochondrial inner membrane. Furthermore, the involvement of hydroxy radicals, which have been demonstrated to be

  13. Mixed time slicing in path integral simulations

    International Nuclear Information System (INIS)

    Steele, Ryan P.; Zwickl, Jill; Shushkov, Philip; Tully, John C.

    2011-01-01

    A simple and efficient scheme is presented for using different time slices for different degrees of freedom in path integral calculations. This method bridges the gap between full quantization and the standard mixed quantum-classical (MQC) scheme and, therefore, still provides quantum mechanical effects in the less-quantized variables. Underlying the algorithm is the notion that time slices (beads) may be 'collapsed' in a manner that preserves quantization in the less quantum mechanical degrees of freedom. The method is shown to be analogous to multiple-time step integration techniques in classical molecular dynamics. The algorithm and its associated error are demonstrated on model systems containing coupled high- and low-frequency modes; results indicate that convergence of quantum mechanical observables can be achieved with disparate bead numbers in the different modes. Cost estimates indicate that this procedure, much like the MQC method, is most efficient for only a relatively few quantum mechanical degrees of freedom, such as proton transfer. In this regime, however, the cost of a fully quantum mechanical simulation is determined by the quantization of the least quantum mechanical degrees of freedom.

  14. Virtual Reality and the Virtual Library.

    Science.gov (United States)

    Oppenheim, Charles

    1993-01-01

    Explains virtual reality, including proper and improper uses of the term, and suggests ways that libraries might be affected by it. Highlights include elements of virtual reality systems; possible virtual reality applications, including architecture, the chemical industry, transport planning, armed forces, and entertainment; and the virtual…

  15. From virtual environment to virtual community

    NARCIS (Netherlands)

    Nijholt, Antinus; Terano, Takao; Nishida, Toyoaki; Namatame, Akira; Tsumoto, Syusaku; Ohsawa, Yukido; Washio, Takashi

    2001-01-01

    We discuss a virtual reality theater environment and its transition to a virtual community by adding domain agents and by allowing multiple users to visit this environment. The environment has been built using VRML (Virtual Reality Modeling Language). We discuss how our ideas about this environment

  16. Experimental setup for deeply virtual Compton scattering (DVCS) experiment in hall A at Jefferson Laboratory

    International Nuclear Information System (INIS)

    Camsonne, A.

    2005-11-01

    The Hall A Deeply Virtual Compton Scattering (DVCS) experiment used the 5.757 GeV polarized electron beam available at Jefferson Laboratory and ran from september until december 2004. Using the standard Hall A left high resolution spectrometer three kinematical points were taken at a fixed x b (jorken) = 0.32 value for three Q 2 values: 1.5 GeV 2 , 1.91 GeV 2 , 2.32 GeV 2 . An electromagnetic Lead Fluoride calorimeter and a proton detector scintillator array designed to work at a luminosity of 10 37 cm -2 s -1 were added to ensure the exclusivity of the DVCS reaction. In addition to the new detectors new custom electronics was used: a calorimeter trigger module which determines if an electron photon coincidence has occurred and a sampling system allowing to deal with pile-up events during the offline analysis. Finally the data from the kinematic at Q 2 = 2.32 GeV 2 and s = 5.6 GeV 2 allowed to get a preliminary result for the exclusive π 0 electroproduction on the proton. (author)

  17. Virtual grasping: closed-loop force control using electrotactile feedback.

    Science.gov (United States)

    Jorgovanovic, Nikola; Dosen, Strahinja; Djozic, Damir J; Krajoski, Goran; Farina, Dario

    2014-01-01

    Closing the control loop by providing somatosensory feedback to the user of a prosthesis is a well-known, long standing challenge in the field of prosthetics. Various approaches have been investigated for feedback restoration, ranging from direct neural stimulation to noninvasive sensory substitution methods. Although there are many studies presenting closed-loop systems, only a few of them objectively evaluated the closed-loop performance, mostly using vibrotactile stimulation. Importantly, the conclusions about the utility of the feedback were partly contradictory. The goal of the current study was to systematically investigate the capability of human subjects to control grasping force in closed loop using electrotactile feedback. We have developed a realistic experimental setup for virtual grasping, which operated in real time, included a set of real life objects, as well as a graphical and dynamical model of the prosthesis. We have used the setup to test 10 healthy, able bodied subjects to investigate the role of training, feedback and feedforward control, robustness of the closed loop, and the ability of the human subjects to generalize the control to previously "unseen" objects. Overall, the outcomes of this study are very optimistic with regard to the benefits of feedback and reveal various, practically relevant, aspects of closed-loop control.

  18. Virtual Grasping: Closed-Loop Force Control Using Electrotactile Feedback

    Directory of Open Access Journals (Sweden)

    Nikola Jorgovanovic

    2014-01-01

    Full Text Available Closing the control loop by providing somatosensory feedback to the user of a prosthesis is a well-known, long standing challenge in the field of prosthetics. Various approaches have been investigated for feedback restoration, ranging from direct neural stimulation to noninvasive sensory substitution methods. Although there are many studies presenting closed-loop systems, only a few of them objectively evaluated the closed-loop performance, mostly using vibrotactile stimulation. Importantly, the conclusions about the utility of the feedback were partly contradictory. The goal of the current study was to systematically investigate the capability of human subjects to control grasping force in closed loop using electrotactile feedback. We have developed a realistic experimental setup for virtual grasping, which operated in real time, included a set of real life objects, as well as a graphical and dynamical model of the prosthesis. We have used the setup to test 10 healthy, able bodied subjects to investigate the role of training, feedback and feedforward control, robustness of the closed loop, and the ability of the human subjects to generalize the control to previously “unseen” objects. Overall, the outcomes of this study are very optimistic with regard to the benefits of feedback and reveal various, practically relevant, aspects of closed-loop control.

  19. Progress on the Femto-Slicing Project at the Synchrotron SOLEIL

    International Nuclear Information System (INIS)

    Prigent, P; Hollander, Ph; Labat, M; Couprie, M E; Marlats, J L; Laulhé, C; Luning, J; Moreno, T; Morin, P; Nadji, A; Polack, F; Ravy, S; Silly, M; Sirotti, F

    2013-01-01

    The aim of the Femto-Slicing project at SOLEIL is to generate 100 fs X-rays pulses on two beamlines, CRISTAL and TEMPO, for pump-probe experiments in the hard and soft X-rays regions. Two fs lasers are currently in operation on TEMPO and CRISTAL for pump-probe experiments on the ps time scale enabling time resolved photoemission and photodiffraction studies. The Femto-Slicing project is based on the fs laser of the CRISTAL beamline, which can be adjusted to deliver 3 mJ pulses of 30 fs duration at 2.5 kHz. The laser beam will be separated in three branches: one delivering about 2 mJ to the modulator Wiggler and the other ones delivering the remaining energy to the TEMPO and CRISTAL experiments. This layout will yield natural synchronization between IR laser pump and X-ray probe pulses, only affected by jitter associated with beam transport. In this paper, we present the current status of the Femto-Slicing project at SOLEIL, with particular emphasis on the expected performance, and the design and construction of the laser beam transport and the diagnostics implementation.

  20. Fourier-based approach to interpolation in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2001-01-01

    It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal direction and because the exploitation of the redundancy of fanbeam data acquired over 360 degree sign to generate additional longitudinal samples does not automatically eliminate the aliasing. In this paper we demonstrate that for pitches near 1 or lower, the redundant fanbeam data, when used properly, can provide sufficient information to satisfy a generalized sampling theorem and thus to eliminate aliasing. We develop and evaluate a Fourier-based algorithm, called 180FT, that accomplishes this. As background we present a second Fourier-based approach, called 360FT, that makes use only of the directly measured data. Both Fourier-based approaches exploit the fast Fourier transform and the Fourier shift theorem to generate from the helical projection data a set of fanbeam sinograms corresponding to equispaced transverse slices. Slice-by-slice reconstruction is then performed by use of two-dimensional fanbeam algorithms. The proposed approaches are compared to their counterparts based on the use of linear interpolation - the 360LI and 180LI approaches. The aliasing suppression property of the 180FT approach is a clear advantage of the approach and represents a step toward the desirable goal of achieving uniform longitudinal resolution properties in reconstructed helical CT volumes

  1. Measurement and analysis of the thoracic patient setup deviations in routine radiotherapy

    International Nuclear Information System (INIS)

    Jia Mingxuan; Zou Huawei; Wu Rong; Sun Jian; Dong Xiaoqi

    2003-01-01

    Objective: To determine the magnitude of the setup deviations of the thoracic patients in routine radiotherapy. Methods: Altogether 408 films for 21 thoracic patients were recorded using the electronic portal imaging device (EPID), and comparison with reference CT simulator digitally-reconstructed radiograph (DRR) for anterior-posterior fields was performed. The deviation of setup for 21 patients in the left-right (RL), superior-inferior (SI) directions and rotation about the anterior-posterior (AP) axis were measured and analyzed. Results: Without immobilization device, the mean translational and rotational setup deviations were (0.7±3.1) mm and (1.5±4.1) mm in the RL and SI directions, respectively, and (0.3±2.4) degree about AP axis. With immobilization device, the mean translational and rotational setup deviations were (0.5±2.4) mm and (0.8±2.7) mm in the RL and SI directions respectively, and (0.2±1.6) degree about AP axis. Conclusion: The setup deviations in thoracic patients irradiation may be reduced with the use of the immobilization device. The setup deviation in the SI direction is greater than that in the RL direction. The setup deviations are mainly random errors

  2. Optical microwave filter based on spectral slicing by use of arrayed waveguide gratings.

    Science.gov (United States)

    Pastor, Daniel; Ortega, Beatriz; Capmany, José; Sales, Salvador; Martinez, Alfonso; Muñoz, Pascual

    2003-10-01

    We have experimentally demonstrated a new optical signal processor based on the use of arrayed waveguide gratings. The structure exploits the concept of spectral slicing combined with the use of an optical dispersive medium. The approach presents increased flexibility from previous slicing-based structures in terms of tunability, reconfiguration, and apodization of the samples or coefficients of the transversal optical filter.

  3. An assessment of the number of CT slices necessary to plan breast radiotherapy

    International Nuclear Information System (INIS)

    Vincent, D.; Beckham, W.; Delaney, G.

    1999-01-01

    The aim of this study was to evaluate the number of CT slices required to produce satisfactory dose distribution for tangential field irradiation of the chest wall and breast and to assess correlation of this with the volume of breast tissue treated. We conclude that a single-slice plan is unsatisfactory in providing sufficient information about the dose variation across the treatment volume and that ideally a 3D plan with DVHs should be produced. If the required data is unavailable then a minimum of three slices should be used as an approximation. We also propose a software tool for treatment planning systems, which calculates the percentage of the total PTV having dose outside the ICRU 50 radiation dose distribution homogeneity guideline range

  4. Set-up for steam generator tube bundle washing after explosion expanding the tubes

    International Nuclear Information System (INIS)

    Osipov, S.I.; Kal'nin, A.Ya.; Mazanenko, M.F.

    1985-01-01

    Set-up for steam generator tube bundle washing after the explosion expanding of tubes is described. Washing is accomplished by distillate. Steam is added to distillate for heating, and compersed air for preventing hydraulic shock. The set-up is equiped by control equipment. Set-up performances are presented. Time for one steam generator washing constitutes 8-12 h. High economic efficiency is realized due to the set-up introduction

  5. Water level effects on breaking wave setup for Pacific Island fringing reefs

    Science.gov (United States)

    Becker, J. M.; Merrifield, M. A.; Ford, M.

    2014-02-01

    The effects of water level variations on breaking wave setup over fringing reefs are assessed using field measurements obtained at three study sites in the Republic of the Marshall Islands and the Mariana Islands in the western tropical Pacific Ocean. At each site, reef flat setup varies over the tidal range with weaker setup at high tide and stronger setup at low tide for a given incident wave height. The observed water level dependence is interpreted in the context of radiation stress gradients specified by an idealized point break model generalized for nonnormally incident waves. The tidally varying setup is due in part to depth-limited wave heights on the reef flat, as anticipated from previous reef studies, but also to tidally dependent breaking on the reef face. The tidal dependence of the breaking is interpreted in the context of the point break model in terms of a tidally varying wave height to water depth ratio at breaking. Implications for predictions of wave-driven setup at reef-fringed island shorelines are discussed.

  6. 640-slice DVCT multi-dimensionally and dynamically presents changes in bladder volume and urine flow rate

    Science.gov (United States)

    Su, Yunshan; Fang, Kewei; Mao, Chongwen; Xiang, Shutian; Wang, Jin; Li, Yingwen

    2018-01-01

    The present study aimed to explore the application of 640-slice dynamic volume computed tomography (DVCT) to excretory cystography and urethrography. A total of 70 healthy subjects were included in the study. Excretory cystography and urethrography using 640-slice DVCT was conducted to continuously record the motions of the bladder and the proximal female and male urethra. The patients' voiding process was divided into early, early to middle, middle, middle to late, and late voiding phases. The subjects were analyzed using DVCT and conventional CT. The cross-sectional areas of various sections of the male and female urethra were evaluated, and the average urine flow rate was calculated. The 640-slice DVCT technique was used to dynamically observe the urine flow rate and changes in bladder volume at all voiding phases. The urine volume detected by 640-slice DVCT exhibited no significant difference compared with the actual volume, and no significant difference compared with that determined using conventional CT. Furthermore, no significant difference in the volume of the bladder at each phase of the voiding process was detected between 640-slice DVCT and conventional CT. The results indicate that 640-slice DVCT can accurately evaluate the status of the male posterior urethra and female urethra. In conclusion, 640-slice DVCT is able to multi-dimensionally and dynamically present changes in bladder volume and urine flow rate, and could obtain similar results to conventional CT in detecting urine volume, as well as the status of the male posterior urethra and female urethra. PMID:29467853

  7. VITEX 2016 : Evaluation of learning objectives and exercise set-up

    NARCIS (Netherlands)

    Rijk, R. van; Stubbé-Alberts, H.E.

    2016-01-01

    To strengthen awareness of the need for cooperation, between public and private partners, and between countries, a new exercise set-up was developed. The VITEX exercise set-up is a table top exercise that aims to bring relevant networks together, and supports cooperation and collaboration between

  8. Congenital coronary artery anomalies: diagnosis with 64 slice multidetector row computed tomography coronary angiography: A single Centre Study

    International Nuclear Information System (INIS)

    Srnivasan, K.G.; Gaikward, A.; Kannan, B.R.J.; Ritesh, K.; Ushanandini, K.P.

    2008-01-01

    Full text: Retrospective review of the congenital coronary artery (CA) anomalies detected by a 64-slice multidetector row computed tomographic (MDCT) angiography. The type of the anomaly, imaging characteristics, clinical relevance and the superiority of the MDCT over conventional coronary angiography are discussed. Multidetector row computed tomographic coronary angiography was carried out by the usual technique with 70 cc of non-ionic contrast agent and retrospective electrocardiogram gating. The volume data obtained were reconstructed in axial plane, along with volume-rendered three-dimensional reconstruction and virtual angioscopy in selected patients. The images were analysed by a radiologist, experienced in cardiac CT, and an experienced cardiologist. A retrospective review of the records was carried out, and subjects with congenital coronary anomalies were included in the study. Between 15 November 2005 and 27 February 2007, 1495 MDCT coronary angiograms were carried out. Eleven of them were found to have coronary anomalies. Five had absent left main CA. Two had interarterial course of the left main CA artery passing in between the right ventricular outflow tract and the root of aorta. In one patient, there was aberrant origin of right CA from the left aortic sinus with subsequent interarterial course and another one had aberrant origin of circumflex artery from the right aortic sinus. One patient each of congenitally absent circumflex artery and atresia of the right CA were found. Sixty-four slice MDCT coronary angiography provided accurate depiction of anomalous vessel origin and course along with the complex anatomical relation with the adjacent structures. CTcan be considered as a first-line imaging method for delineating coronary arterial anomalies.

  9. Why IV Setup for Stream Ciphers is Difficult

    DEFF Research Database (Denmark)

    Zenner, Erik

    2007-01-01

    In recent years, the initialization vector (IV) setup has proven to be the most vulnerable point when designing secure stream ciphers. In this paper, we take a look at possible reasons why this is the case, identifying numerous open research problems in cryptography.......In recent years, the initialization vector (IV) setup has proven to be the most vulnerable point when designing secure stream ciphers. In this paper, we take a look at possible reasons why this is the case, identifying numerous open research problems in cryptography....

  10. On SIP Session setup delay for VoIP services over correlated fading channels

    DEFF Research Database (Denmark)

    Fathi, Hanane; Chakraborty, Shyam S.; Prasad, Ramjee

    2006-01-01

    In this paper, the session setup delay of the session initiation protocol (SIP) is studied. The transmissions on both the forward and reverse channel are assumed to experience Markovian errors. The session setup delay is evaluated for different transport protocols, and with the use of the radio...... link protocol (RLP). An adaptive retransmission timer is used to optimize SIP performances. Using numerical results, we find that SIP over user datagram protocol (UDP) instead of transport control protocol (TCP) can make the session setup up to 30% shorter. Also, RLP drastically reduces the session...... setup delay down to 4 to 5 s, even in environments with high frame error rates (10%) and significant correlation in the fading process (fDT=0.02). SIP is compared with its competitor H.323. SIP session setup delay with compressed messages outperforms H.323 session setup delay....

  11. The MAGIC-5 CAD for nodule detection in low dose and thin slice lung CTs

    International Nuclear Information System (INIS)

    Cerello, Piergiorgio

    2010-01-01

    Lung cancer is the leading cause of cancer-related mortality in developed countries. Only 10-15% of all men and women diagnosed with lung cancer live 5 years after the diagnosis. However, the 5-year survival rate for patients diagnosed in the early asymptomatic stage of the disease can reach 70%. Early-stage lung cancers can be diagnosed by detecting non-calcified small pulmonary nodules with computed tomography (CT). Computer-aided detection (CAD) could support radiologists in the analysis of the large amount of noisy images generated in screening programs, where low-dose and thin-slice settings are used. The MAGIC-5 project, funded by the Istituto Nazionale di Fisica Nucleare (INFN, Italy) and Ministero dell'Universita e della Ricerca (MUR, Italy), developed a multi-method approach based on three CAD algorithms to be used in parallel with a merging of their results: the Channeler Ant Model (CAM), based on Virtual Ant Colonies, the Dot-Enhancement/Pleura Surface Normals/VBNA (DE-PSN-VBNA), and the Region Growing Volume Plateau (RGVP). Preliminary results show quite good performances, to be improved with the refining of the single algorithm and the added value of the results merging.

  12. Tomographic apparatus and method for reconstructing planar slices from non-absorbed radiation

    International Nuclear Information System (INIS)

    1976-01-01

    In a tomographic apparatus and method for reconstructing two-dimensional planar slices from linear projections of non-absorbed radiation useful in the fields of medical radiology, microscopy, and non-destructive testing, a beam of radiation in the shape of a fan is passed through an object lying in the same quasi-plane as the object slice and non-absorbtion thereof is recorded on oppositely-situated detectors aligned with the source of radiation. There is relative rotation between the source-detector configuration and the object within the quasi-plane. Periodic values of the detected radiation are taken, convolved with certain functions, and back-projected to produce a two-dimensional output picture on a visual display illustrating a facsimile of the object slice. A series of two-dimensional pictures obtained simultaneously or serially can be combined to produce a three dimensional portrayal of the entire object

  13. X-band EPR setup with THz light excitation of Novosibirsk Free Electron Laser: Goals, means, useful extras

    Science.gov (United States)

    Veber, Sergey L.; Tumanov, Sergey V.; Fursova, Elena Yu.; Shevchenko, Oleg A.; Getmanov, Yaroslav V.; Scheglov, Mikhail A.; Kubarev, Vitaly V.; Shevchenko, Daria A.; Gorbachev, Iaroslav I.; Salikova, Tatiana V.; Kulipanov, Gennady N.; Ovcharenko, Victor I.; Fedin, Matvey V.

    2018-03-01

    Electron Paramagnetic Resonance (EPR) station at the Novosibirsk Free Electron Laser (NovoFEL) user facility is described. It is based on X-band (∼9 GHz) EPR spectrometer and operates in both Continuous Wave (CW) and Time-Resolved (TR) modes, each allowing detection of either direct or indirect influence of high-power NovoFEL light (THz and mid-IR) on the spin system under study. The optics components including two parabolic mirrors, shutters, optical chopper and multimodal waveguide allow the light of NovoFEL to be directly fed into the EPR resonator. Characteristics of the NovoFEL radiation, the transmission and polarization-retaining properties of the waveguide used in EPR experiments are presented. The types of proposed experiments accessible using this setup are sketched. In most practical cases the high-power radiation applied to the sample induces its rapid temperature increase (T-jump), which is best visible in TR mode. Although such influence is a by-product of THz radiation, this thermal effect is controllable and can deliberately be used to induce and measure transient signals of arbitrary samples. The advantage of tunable THz radiation is the absence of photo-induced processes in the sample and its high penetration ability, allowing fast heating of a large portion of virtually any sample and inducing intense transients. Such T-jump TR EPR spectroscopy with THz pulses has been previewed for the two test samples, being a useful supplement for the main goals of the created setup.

  14. Analysis and classification of commercial ham slice images using directional fractal dimension features.

    Science.gov (United States)

    Mendoza, Fernando; Valous, Nektarios A; Allen, Paul; Kenny, Tony A; Ward, Paddy; Sun, Da-Wen

    2009-02-01

    This paper presents a novel and non-destructive approach to the appearance characterization and classification of commercial pork, turkey and chicken ham slices. Ham slice images were modelled using directional fractal (DF(0°;45°;90°;135°)) dimensions and a minimum distance classifier was adopted to perform the classification task. Also, the role of different colour spaces and the resolution level of the images on DF analysis were investigated. This approach was applied to 480 wafer thin ham slices from four types of hams (120 slices per type): i.e., pork (cooked and smoked), turkey (smoked) and chicken (roasted). DF features were extracted from digitalized intensity images in greyscale, and R, G, B, L(∗), a(∗), b(∗), H, S, and V colour components for three image resolution levels (100%, 50%, and 25%). Simulation results show that in spite of the complexity and high variability in colour and texture appearance, the modelling of ham slice images with DF dimensions allows the capture of differentiating textural features between the four commercial ham types. Independent DF features entail better discrimination than that using the average of four directions. However, DF dimensions reveal a high sensitivity to colour channel, orientation and image resolution for the fractal analysis. The classification accuracy using six DF dimension features (a(90°)(∗),a(135°)(∗),H(0°),H(45°),S(0°),H(90°)) was 93.9% for training data and 82.2% for testing data.

  15. Using a high-speed movie camera to evaluate slice dropping in clinical image interpretation with stack mode viewers.

    Science.gov (United States)

    Yakami, Masahiro; Yamamoto, Akira; Yanagisawa, Morio; Sekiguchi, Hiroyuki; Kubo, Takeshi; Togashi, Kaori

    2013-06-01

    The purpose of this study is to verify objectively the rate of slice omission during paging on picture archiving and communication system (PACS) viewers by recording the images shown on the computer displays of these viewers with a high-speed movie camera. This study was approved by the institutional review board. A sequential number from 1 to 250 was superimposed on each slice of a series of clinical Digital Imaging and Communication in Medicine (DICOM) data. The slices were displayed using several DICOM viewers, including in-house developed freeware and clinical PACS viewers. The freeware viewer and one of the clinical PACS viewers included functions to prevent slice dropping. The series was displayed in stack mode and paged in both automatic and manual paging modes. The display was recorded with a high-speed movie camera and played back at a slow speed to check whether slices were dropped. The paging speeds were also measured. With a paging speed faster than half the refresh rate of the display, some viewers dropped up to 52.4 % of the slices, while other well-designed viewers did not, if used with the correct settings. Slice dropping during paging was objectively confirmed using a high-speed movie camera. To prevent slice dropping, the viewer must be specially designed for the purpose and must be used with the correct settings, or the paging speed must be slower than half of the display refresh rate.

  16. Microfilament Contraction Promotes Rounding of Tunic Slices: An Integumentary Defense System in the Colonial Ascidian Aplidium yamazii.

    Science.gov (United States)

    Hirose, E; Ishii, T

    1995-08-01

    In Aplidium yamazii, when a slice of a live colony (approximately 0.5 mm thick) was incubated in seawater for 12 h, the slice became a round tunic fragment. This tunic rounding was inhibited by freezing of the slices, incubation with Ca2+-Mg2+ -free seawater, or addition of cytochalasin B. Staining of microfilaments in the slices with phalloidin-FITC showed the existence of a cellular network in the tunic. Contraction of this cellular network probably promotes rounding of the tunic slice. In electron microscopic observations, a new tunic cuticle regenerated at the surface of the round tunic fragments; the tunic cuticle did not regenerate in newly sliced specimens nor in specimens in which rounding was experimentally inhibited. Based on these results, an integumentary defense system is proposed in this species as follows. (1) When the colony is wounded externally, contraction of the cellular network promotes tunic contraction around the wound. (2) The wound is almost closed by tunic contraction. (3) Tunic contraction increases the density of the filamentous components of the tunic at the wound, and it may accelerate the regeneration of tunic cuticle there.

  17. Comparison between powder and slices diffraction methods in teeth samples

    Energy Technology Data Exchange (ETDEWEB)

    Colaco, Marcos V.; Barroso, Regina C. [Universidade do Estado do Rio de Janeiro (IF/UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada; Porto, Isabel M. [Universidade Estadual de Campinas (FOP/UNICAMP), Piracicaba, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia; Gerlach, Raquel F. [Universidade de Sao Paulo (FORP/USP), Rieirao Preto, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia, Estomatologia e Fisiologia; Costa, Fanny N. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10{sup -1}0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  18. Comparison between powder and slices diffraction methods in teeth samples

    International Nuclear Information System (INIS)

    Colaco, Marcos V.; Barroso, Regina C.; Porto, Isabel M.; Gerlach, Raquel F.; Costa, Fanny N.

    2011-01-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10 -1 0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  19. A Novel Slicing Method for Thin Supercapacitors.

    Science.gov (United States)

    Sun, Hao; Fu, Xuemei; Xie, Songlin; Jiang, Yishu; Guan, Guozhen; Wang, Bingjie; Li, Houpu; Peng, Huisheng

    2016-08-01

    Thin and flexible supercapacitors with low cost and individual variation are fabricated by a new and efficient slicing method. Tunable output voltage and energy can be realized with a high specific capacitance of 248.8 F g(-1) or 150.8 F cm(-3) , which is well maintained before and after bending. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Detecting Psychopathy from Thin Slices of Behavior

    Science.gov (United States)

    Fowler, Katherine A.; Lilienfeld, Scott O.; Patrick, Christopher J.

    2009-01-01

    This study is the first to demonstrate that features of psychopathy can be reliably and validly detected by lay raters from "thin slices" (i.e., small samples) of behavior. Brief excerpts (5 s, 10 s, and 20 s) from interviews with 96 maximum-security inmates were presented in video or audio form or in both modalities combined. Forty raters used…

  1. A new tribological experimental setup to study confined and sheared monolayers.

    Science.gov (United States)

    Fu, L; Favier, D; Charitat, T; Gauthier, C; Rubin, A

    2016-03-01

    We have developed an original experimental setup, coupling tribology, and velocimetry experiments together with a direct visualization of the contact. The significant interest of the setup is to measure simultaneously the apparent friction coefficient and the velocity of confined layers down to molecular scale. The major challenge of this experimental coupling is to catch information on a nanometer-thick sheared zone confined between a rigid spherical indenter of millimetric radius sliding on a flat surface at constant speed. In order to demonstrate the accuracy of this setup to investigate nanometer-scale sliding layers, we studied a model lipid monolayer deposited on glass slides. It shows that our experimental setup will, therefore, help to highlight the hydrodynamic of such sheared confined layers in lubrication, biolubrication, or friction on solid polymer.

  2. Slice of a LEP bending magnet

    CERN Multimedia

    This is a slice of a LEP dipole bending magnet, made as a concrete and iron sandwich. The bending field needed in LEP is small (about 1000 Gauss), equivalent to two of the magnets people stick on fridge doors. Because it is very difficult to keep a low field steady, a high field was used in iron plates embedded in concrete. A CERN breakthrough in magnet design, LEP dipoles can be tuned easily and are cheaper than conventional magnets.

  3. Neuropeptide processing in regional brain slices: Effect of conformation and sequence

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z.W.; Bijl, W.A.; van Nispen, J.W.; Brendel, K.; Davis, T.P. (Univ. of Arizona, Tucson (USA))

    1990-05-01

    The central enzymatic stability of des-enkephalin-gamma-endorphin and its synthetic analogs (cycloN alpha 6, C delta 11)beta-endorphin-(6-17) and (Pro7, Lys(Ac)9)-beta-endorphin(6-17) was studied in vitro using a newly developed, regionally dissected rat brain slice, time course incubation procedure. Tissue slice viability was estimated as the ability of the brain slice to take up or release gamma-(3H)aminobutyric acid after high K+ stimulation. Results demonstrated stability of uptake/release up to 5 hr of incubation, suggesting tissue viability over this period. The estimated half-life of peptides based on the results obtained in our incubation protocol suggest that the peptides studied are metabolized at different rates in the individual brain regions tested. A good correlation exists between the high enzyme activity of neutral endopeptidase and the rapid degradation of des-enkephalin-gamma-endorphin and (cycloN alpha 6, C delata 11)beta-endorphin-(6-17) in caudate putamen. Proline substitution combined with lysine acetylation appears to improve resistance to enzymatic metabolism in caudate putamen and hypothalamus. However, cyclization of des-enkephalin-gamma-endorphin forming an amide bond between the alpha-NH2 of the N-terminal threonine and the gamma-COOH of glutamic acid did not improve peptide stability in any brain region tested. The present study has shown that the brain slice technique is a valid and unique approach to study neuropeptide metabolism in small, discrete regions of rat brain where peptides, peptidases and receptors are colocalized and that specific structural modifications can improve peptide stability.

  4. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  5. Isoproterenol effects evaluated in heart slices of human and rat in comparison to rat heart in vivo

    International Nuclear Information System (INIS)

    Herrmann, Julia E.; Heale, Jason; Bieraugel, Mike; Ramos, Meg; Fisher, Robyn L.; Vickers, Alison E.M.

    2014-01-01

    Human response to isoproterenol induced cardiac injury was evaluated by gene and protein pathway changes in human heart slices, and compared to rat heart slices and rat heart in vivo. Isoproterenol (10 and 100 μM) altered human and rat heart slice markers of oxidative stress (ATP and GSH) at 24 h. In this in vivo rat study (0.5 mg/kg), serum troponin concentrations increased with lesion severity, minimal to mild necrosis at 24 and 48 h. In the rat and the human heart, isoproterenol altered pathways for apoptosis/necrosis, stress/energy, inflammation, and remodeling/fibrosis. The rat and human heart slices were in an apoptotic phase, while the in vivo rat heart exhibited necrosis histologically and further progression of tissue remodeling. In human heart slices genes for several heat shock 70 kD members were altered, indicative of stress to mitigate apoptosis. The stress response included alterations in energy utilization, fatty acid processing, and the up-regulation of inducible nitric oxide synthase, a marker of increased oxidative stress in both species. Inflammation markers linked with remodeling included IL-1α, Il-1β, IL-6 and TNFα in both species. Tissue remodeling changes in both species included increases in the TIMP proteins, inhibitors of matrix degradation, the gene/protein of IL-4 linked with cardiac fibrosis, and the gene Ccl7 a chemokine that induces collagen synthesis, and Reg3b a growth factor for cardiac repair. This study demonstrates that the initial human heart slice response to isoproterenol cardiac injury results in apoptosis, stress/energy status, inflammation and tissue remodeling at concentrations similar to that in rat heart slices. - Highlights: • Human response to isoproterenol induced cardiac injury evaluated in heart slices. • Isoproterenol altered apoptosis, energy, inflammation and remodeling pathways. • Human model verified by comparison to rat heart slices and rat heart in vivo. • Human and rat respond to isoproterenol

  6. Infrared-Guided Patient Setup for Lung Cancer Patients

    International Nuclear Information System (INIS)

    Lyatskaya, Yulia; James, Steven; Killoran, Joseph H.; Soto, Ricardo; Mamon, Harvey J.; Chin, Lee; Allen, Aaron M.

    2008-01-01

    Purpose: To evaluate the utility of an infrared-guided patient setup (iGPS) system to reduce the uncertainties in the setup of lung cancer patients. Methods and Materials: A total of 15 patients were setup for lung irradiation using skin tattoos and lateral leveling marks. Daily electronic portal device images and iGPS marker locations were acquired and retrospectively reviewed. The iGPS-based shifts were compared with the daily electronic portal device image shifts using both the central axis iGPS marker and all five iGPS markers. For shift calculation using the five markers, rotational misalignment was included. The level of agreement between the iGPS and portal imaging to evaluate the setup was evaluated as the frequency of the shift difference in the range of 0-5 mm, 5-10 mm, and >10 mm. Results: Data were obtained for 450 treatment sessions for 15 patients. The difference in the isocenter shifts between the weekly vs. daily images was 0-5 mm in 42%, 5-10 mm in 30%, and >10 mm in 10% of the images. The shifts seen using the iGPS data were 0-5 mm in 81%, 5-10 mm in 14%, and >10 mm in 5%. Using only the central axis iGPS marker, the difference between the iGPS and portal images was 10 mm in 7% in the left-right direction and 73%, 18%, and 9% in the superoinferior direction, respectively. When all five iGPS markers were used, the disagreements between the iGPS and portal image shifts >10 mm were reduced from 7% to 2% in the left-right direction and 9% to 3% in the superoinferior direction. Larger reductions were also seen (e.g., a reduction from 50% to 0% in 1 patient). Conclusion: The daily iGPS-based shifts correlated well with the daily electronic portal device-based shifts. When patient movement has nonlinear rotational components, a combination of surface markers and portal images might be particularly beneficial to improve the setup for lung cancer patients

  7. Virtual synchrotron experiments for deep Earth studies

    Science.gov (United States)

    Jackson, J. M.; Alp, E. E.; Zhao, J.; Alatas, A.; Sturhahn, W.

    2011-12-01

    National facilities offer one-of-a-kind opportunities to apply state-of-the-art experimental techniques to the pressing scientific problems of today. Yet, few students are able to experience research projects at national facilities due to limited accessibility caused in part by limited involvement in the local academic institution, constrained working areas at the experimental stations, and/or travel costs. We present a virtual and remote beam-line for deep Earth mineral physics studies using nuclear resonant and inelastic x-ray scattering methods at Sector 3 of the Advanced Photon Source at Argonne National Laboratory. Off-site students have the capability of controlling their measurements via secure internet connections and webcams. Students can access a 'view only mode' for ease of interaction and safety-control. More experienced users have exclusive control of the experiment and can remotely change variables within the experimental setup.

  8. Options in virtual 3D, optical-impression-based planning of dental implants.

    Science.gov (United States)

    Reich, Sven; Kern, Thomas; Ritter, Lutz

    2014-01-01

    If a 3D radiograph, which in today's dentistry often consists of a CBCT dataset, is available for computerized implant planning, the 3D planning should also consider functional prosthetic aspects. In a conventional workflow, the CBCT is done with a specially produced radiopaque prosthetic setup that makes the desired prosthetic situation visible during virtual implant planning. If an exclusively digital workflow is chosen, intraoral digital impressions are taken. On these digital models, the desired prosthetic suprastructures are designed. The entire datasets are virtually superimposed by a "registration" process on the corresponding structures (teeth) in the CBCTs. Thus, both the osseous and prosthetic structures are visible in one single 3D application and make it possible to consider surgical and prosthetic aspects. After having determined the implant positions on the computer screen, a drilling template is designed digitally. According to this design (CAD), a template is printed or milled in CAM process. This template is the first physically extant product in the entire workflow. The article discusses the options and limitations of this workflow.

  9. Abscisic Acid Accumulation in Spinach Leaf Slices in the Presence of Penetrating and Nonpenetrating Solutes 1

    Science.gov (United States)

    Creelman, Robert A.; Zeevaart, Jan A. D.

    1985-01-01

    Abscisic acid (ABA) accumulated in detached, wilted leaves of spinach (Spinacia oleracea L. cv Savoy Hybrid 612) and reached a maximum level within 3 to 4 hours. The increase in ABA over that found in detached turgid leaves was approximately 10-fold. The effects of water stress could be mimicked by the use of thin slices of spinach leaves incubated in the presence of 0.6 molar mannitol, a compound which causes plasmolysis (loss of turgor). About equal amounts of ABA were found both in the leaf slices and in detached leaves, whereas 2 to 4 times more ABA accumulated in the medium than in the slices. When spinach leaf slices were incubated with ethylene glycol, a compound which rapidly penetrates the cell membrane causing a decrease in the osmotic potential of the tissue and only transient loss of turgor, no ABA accumulated. Ethylene glycol was not inhibitory with respect to ABA accumulation. Spinach leaf slices incubated in both ethylene glycol and mannitol had ABA levels similar to those found when slices were incubated with mannitol alone. Increases similar to those found with mannitol also occurred when Aquacide III, a highly purified form of polyethylene glycol, was used. Aquacide III causes cytorrhysis, a situation similar to that found in wilted leaves. Thus, it appears that loss of turgor is essential for ABA accumulation. When spinach leaf slices were incubated with solutes which are supposed to disturb membrane integrity (KHSO3, 2-propanol, or KCl) no increase in ABA was observed. These data indicate that, with respect to the accumulation of ABA, mannitol caused a physical stress (loss of turgor) rather than a chemical stress (membrane damage). PMID:16664022

  10. Evaluation of the possibility to use thick slabs of reconstructed outer breast tomosynthesis slice images

    Science.gov (United States)

    Petersson, Hannie; Dustler, Magnus; Tingberg, Anders; Timberg, Pontus

    2016-03-01

    The large image volumes in breast tomosynthesis (BT) have led to large amounts of data and a heavy workload for breast radiologists. The number of slice images can be decreased by combining adjacent image planes (slabbing) but the decrease in depth resolution can considerably affect the detection of lesions. The aim of this work was to assess if thicker slabbing of the outer slice images (where lesions seldom are present) could be a viable alternative in order to reduce the number of slice images in BT image volumes. The suggested slabbing (an image volume with thick outer slabs and thin slices between) were evaluated in two steps. Firstly, a survey of the depth of 65 cancer lesions within the breast was performed to estimate how many lesions would be affected by outer slabs of different thicknesses. Secondly, a selection of 24 lesions was reconstructed with 2, 6 and 10 mm slab thickness to evaluate how the appearance of lesions located in the thicker slabs would be affected. The results show that few malignant breast lesions are located at a depth less than 10 mm from the surface (especially for breast thicknesses of 50 mm and above). Reconstruction of BT volumes with 6 mm slab thickness yields an image quality that is sufficient for lesion detection for a majority of the investigated cases. Together, this indicates that thicker slabbing of the outer slice images is a promising option in order to reduce the number of slice images in BT image volumes.

  11. Slicing Cuts on Food Materials Using Robotic-Controlled Razor Blade

    Directory of Open Access Journals (Sweden)

    Debao Zhou

    2011-01-01

    Full Text Available Cutting operations using blades can arise in a number of industries, for example, food processing industry, in which cheese, fruit and vegetable, even meat, are involved. Certain questions will rise during these works, such as “why pressing-and-slicing cuts use less force than pressing-only cuts” and “how is the influence of the blade cutting-edge on force”. To answer these questions, this research developed a mathematical expression of the cutting stress tensor. Based on the analysis of the stress tensor on the contact surface, the influence of the blade edge-shape and slicing angle on the resultant cutting force were formulated and discussed. These formulations were further verified using experimental results by robotic cutting of potatoes. Through studying the change of the cutting force, the optimal slicing angle can be obtained in terms of maximum feeding distance and minimum cutting force. Based on the blade sharpness properties and the specific materials, the required cutting force can be predicted. These formulation and experimental results explained the basic theory of blade cutting fracture and further provided the support to optimize the cutting mechanism design and to develop the force control algorithms for the automation of blade cutting operations.

  12. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  13. Time-slicing subsystem of the biology small-angle x-ray scattering station at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Stubblefield, F.W.

    1985-11-01

    The time-slicing subsystem of the Biology Small-Angle X-ray Scattering divides the time period during which the data for small-angle x-ray diffraction patterns from biological samples is collected into time slices (or frames). The subsystem, being part of a multiprocessor experiment control and data acquisition system, has its own dedicated processor; it also has special-purpose front-end electronics sufficient to generate the gating and other control signals required to produce a sequence of as many as 256 time slices, measured with a basic time unit of 1 μsec. The electronics also synchronizes with execution of the time slice sequence the application of stimuli to the biological sample, the measurement of voltages generated by the sample, and the application of auxiliary device trigger pulses and routes detector data and auxiliary scaler data into appropriate time-slice-indexed buffers in a large external data memory array. The structure of the entire experiment control and data acquisition system is briefly reviewed. Details of the structure and operation of the time slice subsystem are presented. 7 refs., 5 figs

  14. Virtual Team Governance: Addressing the Governance Mechanisms and Virtual Team Performance

    Science.gov (United States)

    Zhan, Yihong; Bai, Yu; Liu, Ziheng

    As technology has improved and collaborative software has been developed, virtual teams with geographically dispersed members spread across diverse physical locations have become increasingly prominent. Virtual team is supported by advancing communication technologies, which makes virtual teams able to largely transcend time and space. Virtual teams have changed the corporate landscape, which are more complex and dynamic than traditional teams since the members of virtual teams are spread on diverse geographical locations and their roles in the virtual team are different. Therefore, how to realize good governance of virtual team and arrive at good virtual team performance is becoming critical and challenging. Good virtual team governance is essential for a high-performance virtual team. This paper explores the performance and the governance mechanism of virtual team. It establishes a model to explain the relationship between the performance and the governance mechanisms in virtual teams. This paper is focusing on managing virtual teams. It aims to find the strategies to help business organizations to improve the performance of their virtual teams and arrive at the objectives of good virtual team management.

  15. Effects of metal ions on agonist-stimulated accumulation of inositol phosphates in hippocampal and cortical slices

    International Nuclear Information System (INIS)

    Bonner, M.J.; Tilson, H.A.

    1990-01-01

    [ 3 H]-inositol was incorporated into rat hippocampal or cortical slices. Zinc chloride and three different forms of inorganic lead compounds, lead chloride, lead nitrate, and lead acetate were used to stimulate PI metabolism at concentrations between 10 -15 and 10 -9 M. At these concentrations, these metal ions did not produce any significant stimulation of IP release. In birth hippocampal and cortical slices, carbachol produced equal levels of IP release. Norepinephrine (NE) produced a 10-15% higher stimulation than carbachol. When the metal ions were added to hippocampal slices together with the agonists, there was a general suppression of carbachol- or NE-induced IP release. This general suppression was not observed in cortical slices. These data suggest that the trace metals used inhibit agonist-induced second messenger release in the hippocampus

  16. Microbial growth and sensory quality of dried potato slices irradiated by electrons

    International Nuclear Information System (INIS)

    Kim, Hyun-Jin; Song, Hyeon-Jeong; Song, Kyung-Bin

    2011-01-01

    Electron beam irradiation was applied to secure the microbial safety of dried purple sweet potato. After purple sweet potato slices had been dehydrated with 20% (w/w) maltodextrin solution, the samples were irradiated at doses 2, 4, 6, 8, and 10 kGy and then stored at 20 o C for 60 days. Microbiological data indicated that the populations of total aerobic bacteria and of yeast and molds significantly decreased with increase in irradiation dosage. Specifically, microbial load was reduced by about three log cycles at 6 kGy compared to those of the control. Based on the color measurement of the potato slices, electron beam irradiation treatment did not affect the color quality. Sensory evaluation results also showed that electron beam irradiation did not affect overall sensory scores during storage. These results suggest that electron beam irradiation could be useful for improving microbial safety without impairing the quality of the potato slices during storage.

  17. Influence of Daily Set-Up Errors on Dose Distribution During Pelvis Radiotherapy

    International Nuclear Information System (INIS)

    Kasabasic, M.; Ivkovic, A.; Faj, D.; Rajevac, V.; Sobat, H.; Jurkovic, S.

    2011-01-01

    An external beam radiotherapy (EBRT) using megavoltage beam of linear accelerator is usually the treatment of choice for the cancer patients. The goal of EBRT is to deliver the prescribed dose to the target volume, with as low as possible dose to the surrounding healthy tissue. A large number of procedures and different professions involved in radiotherapy process, uncertainty of equipment and daily patient set-up errors can cause a difference between the planned and delivered dose. We investigated a part of this difference caused by daily patient set-up errors. Daily set-up errors for 35 patients were measured. These set-up errors were simulated on 5 patients, using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The differences in dose distributions between the planned and shifted ''geometry'' were investigated. Additionally, an influence of the error on treatment plan selection was checked by analyzing the change in dose volume histograms, planning target volume conformity index (CI P TV) and homogeneity index (HI). Simulations showed that patient daily set-up errors can cause significant differences between the planned and actual dose distributions. Moreover, for some patients those errors could influence the choice of treatment plan since CI P TV fell under 97 %. Surprisingly, HI was not as sensitive as CI P TV on set-up errors. The results showed the need for minimizing daily set-up errors by quality assurance programme. (author)

  18. Exposure (mAs) optimisation of a multi-detector CT protocol for hepatic lesion detection: are thinner slices better?

    International Nuclear Information System (INIS)

    Dobeli, Karen L.; Lewis, Sarah J.; Meikle, Steven R.; Brennan, Patrick C.; Thiele, David L.

    2014-01-01

    The purpose of this work was to determine the exposure-optimised slice thickness for hepatic lesion detection with CT. A phantom containing spheres (diameter 9.5, 4.8 and 2.4mm) with CT density 10 HU below the background (50 HU) was scanned at 125, 100, 75 and 50 mAs. Data were reconstructed at 5-, 3- and 1-mm slice thicknesses. Noise, contrast-to-noise ratio (CNR), area under the curve (AUC) as calculated using receiver operating characteristic analysis and sensitivity representing lesion detection were calculated and compared. Compared with the 125 mAs/5mm slice thickness setting, significant reductions in AUC were found for 75 mAs (P<0.01) and 50 mAs (P<0.05) at 1- and 3-mm thicknesses, respectively; sensitivity for the 9.5-mm sphere was significantly reduced for 75 (P<0.05) and 50 mAs (P<0.01) at 1-mm thickness; sensitivity for the 4.8-mm sphere was significantly lower for 100, 75 and 50 mAs at all three slice thicknesses (P<0.05). The 2.4-mm sphere was rarely detected. At each slice thickness, noise at 100, 75 and 50 mAs exposures was approximately 10, 30 and 50% higher, respectively, than that at 125 mAs exposure. CNRs decreased in an irregular manner with reductions in exposure and slice thickness. This study demonstrated no advantage to using slices below 5mm thickness, and consequently thinner slices are not necessarily better.

  19. Application of 2 mm thin-slice scanning with bone algorithm on conventional CT in diagnosis of the pulmonary diseases

    International Nuclear Information System (INIS)

    Zhang Xianheng; Li Xiuhua; Wang Fenghua

    2004-01-01

    Objective: To evaluate the value of 2 mm thin-slice conventional CT scan with bone algorithm in diagnosis and differential diagnosis in the pulmonary diseases. Methods: In total 135 cases of the pulmonary diseases were routinely scanned by conventional scan, 10 mm per slice, with standard algorithm, then the 2 mm thin-slice scan with bone algorithm was performed at the interested region of the lungs. Result: According to the comparative study of the CT signs between 10 mm slice scan with standard algorithm and 2 mm thin-slice scan with bone algorithm, the latter was better on displaying the pulmonary axial interstium, intralobular septum, subpleura lines, honeycombing, 2-5 mm nodulars and anomalies of bronchial wall. Conclusion: According to the study of 135 cases, 2 mm thin-slice scan with bone algorithm is superior to 10 mm slice scan with standard algorithm in demonstrating the pulmonary lesions. It has a similar value with high-resolution spiral CT in the diagnosis of the pulmonary solitary or diffuse nodules, pulmonary diffuse interstitial lesions and the lesions of the airway. It is practical and advisable in the community hospital

  20. Developing a Virtual Museum for the Ancient Wine Trade in Eastern Mediterranean

    Science.gov (United States)

    Kazanis, S.; Kontogianni, G.; Chliverou, R.; Georgopoulos, A.

    2017-08-01

    Digital technologies for representing cultural heritage assets of any size are already maturing. Technological progress has greatly enhanced the art of virtual representation and, as a consequence, it is all the more appealing to the general public and especially to younger generations. The game industry has played a significant role towards this end and has led to the development of edutainment applications. The digital workflow implemented for developing such an application is presented in this paper. A virtual museum has been designed and developed, with the intention to convey the history of trade in the Eastern Mediterranean area, focusing on the Aegean Sea and five productive cities-ports, during a period of more than 500 years. Image based modeling methodology was preferred to ensure accuracy and reliability. The setup in the museum environment, the difficulties encountered and the solutions adopted are discussed, while processing of the images and the production and finishing of the 3D models are described in detail. The virtual museum and edutainment application, MEDWINET, has been designed and developed with the intention to convey the essential information of the wine production and trade routes in the Eastern Mediterranean basin. The user is able to examine the 3D models of the amphorae, while learning about their production and use for trade during the centuries. The application has been evaluated and the results are also discussed.

  1. A slicing-based approach for locating type errors

    NARCIS (Netherlands)

    T.B. Dinesh; F. Tip (Frank)

    1998-01-01

    htmlabstractThe effectiveness of a type checking tool strongly depends on the accuracy of the positional information that is associated with type errors. We present an approach where the location associated with an error message e is defined as a slice P_e of the program P being type checked. We

  2. A slicing-based approach for locating type errors

    NARCIS (Netherlands)

    T.B. Dinesh; F. Tip (Frank)

    1998-01-01

    textabstractThe effectiveness of a type checking tool strongly depends on the accuracy of the positional information that is associated with type errors. We present an approach where the location associated with an error message e is defined as a slice P_e of the program P being type checked. We

  3. Colour behaviour on mango ( Mangifera indica ) slices self ...

    African Journals Online (AJOL)

    The effect of the syrup composition on behaviour colour of self stabilized mango slices in glass jars by hurdle technology during 180 days of storage was studied through 26-2 fractional factorial design. L* (lightness), a* (redness and greenness), and b* (yellowness and blueness) values were measured with a colorimeter ...

  4. Rapid Auditory System Adaptation Using a Virtual Auditory Environment

    Directory of Open Access Journals (Sweden)

    Gaëtan Parseihian

    2011-10-01

    Full Text Available Various studies have highlighted plasticity of the auditory system from visual stimuli, limiting the trained field of perception. The aim of the present study is to investigate auditory system adaptation using an audio-kinesthetic platform. Participants were placed in a Virtual Auditory Environment allowing the association of the physical position of a virtual sound source with an alternate set of acoustic spectral cues or Head-Related Transfer Function (HRTF through the use of a tracked ball manipulated by the subject. This set-up has the advantage to be not being limited to the visual field while also offering a natural perception-action coupling through the constant awareness of one's hand position. Adaptation process to non-individualized HRTF was realized through a spatial search game application. A total of 25 subjects participated, consisting of subjects presented with modified cues using non-individualized HRTF and a control group using individual measured HRTFs to account for any learning effect due to the game itself. The training game lasted 12 minutes and was repeated over 3 consecutive days. Adaptation effects were measured with repeated localization tests. Results showed a significant performance improvement for vertical localization and a significant reduction in the front/back confusion rate after 3 sessions.

  5. Recreating Riser Slugging Flow Based on an Economic Lab-sized Setup

    DEFF Research Database (Denmark)

    Hansen, Lasse; Pedersen, Simon; Yang, Zhenyu

    2013-01-01

    As a kind of periodic phenomenon, the slugging flow in the offshore oil & gas production addresses a lot of attentions, due to its limitation of production rate, periodic overload processing facilities, and even direct cause of emergent shutdown. This work studies the emulation of the riser...... slugging flow in the offshore oil & gas production, by constructing an economical lab-sized setup in the university campus. Firstly, the construction and used components for the lab setup are illustrated; then, the constructed setup is validated by checking the consistency with some existing typical riser...

  6. Regulation of dopamine synthesis and release in striatal and prefrontal cortical brain slices

    International Nuclear Information System (INIS)

    Wolf, M.E.

    1986-01-01

    Brain slices were used to investigate the role of nerve terminal autoreceptors in modulating dopamine (DA) synthesis and release in striatum and prefrontal cortex. Accumulation of dihydroxyphenylalanine (DOPA) was used as an index of tyrosine hydroxylation in vitro. Nomifensine, a DA uptake blocker, inhibited DOPA synthesis in striatal but not prefrontal slices. This effect was reversed by the DA antagonist sulpiride, suggesting it involved activation of DA receptors by elevated synaptic levels of DA. The autoreceptor-selective agonist EMD-23-448 also inhibited striatal but not prefrontal DOPA synthesis. DOPA synthesis was stimulated in both brain regions by elevated K + , however only striatal synthesis could be further enhanced by sulpiride. DA release was measured by following the efflux of radioactivity from brain slices prelabeled with [ 3 H]-DA. EMD-23-448 and apomorphine inhibited, while sulpiride enhanced, the K + -evoked overflow of radioactivity from both striatal and prefrontal cortical slices. These findings suggest that striatal DA nerve terminals possess autoreceptors which modulate tyrosine hydroxylation as well as autoreceptors which modulate release. Alternatively, one site may be coupled to both functions through distinct transduction mechanisms. In contrast, autoreceptors on prefrontal cortical terminals appear to regulate DA release but not DA synthesis

  7. The energy demand of fast neuronal network oscillations: insights from brain slice preparations

    Directory of Open Access Journals (Sweden)

    Oliver eKann

    2012-01-01

    Full Text Available Fast neuronal network oscillations in the gamma range (30-100 Hz in the cerebral cortex have been implicated in higher cognitive functions such as sensual perception, working memory, and, perhaps, consciousness. However, little is known about the energy demand of gamma oscillations. This is mainly caused by technical limitations that are associated with simultaneous recordings of neuronal activity and energy metabolism in small neuronal networks and at the level of mitochondria in vivo. Thus recent studies have focused on brain slice preparations to address the energy demand of gamma oscillations in vitro. Here, reports will be summarized and discussed that combined electrophysiological recordings, oxygen sensor microelectrodes and live-cell fluorescence imaging in acutely prepared slices and organotypic slice cultures of the hippocampus from both, mouse and rat. These reports consistently show that gamma oscillations can be reliably induced in hippocampal slice preparations by different pharmacological tools. They suggest that gamma oscillations are associated with high energy demand, requiring both rapid adaptation of oxidative energy metabolism and sufficient supply with oxygen and nutrients. These findings might help to explain the exceptional vulnerability of higher cognitive functions during pathological processes of the brain, such as circulatory disturbances, genetic mitochondrial diseases, and neurodegeneration.

  8. The ATLAS Level-1 Trigger Timing Setup

    CERN Document Server

    Spiwoks, R; Ellis, Nick; Farthouat, P; Gällnö, P; Haller, J; Krasznahorkay, A; Maeno, T; Pauly, T; Pessoa-Lima, H; Resurreccion-Arcas, I; Schuler, G; De Seixas, J M; Torga-Teixeira, R; Wengler, T

    2005-01-01

    The ATLAS detector at CERN's LHC will be exposed to proton-proton collisions at a bunch-crossing rate of 40 MHz. In order to reduce the data rate, a three-level trigger system selects potentially interesting physics. The first trigger level is implemented in electronics and firmware. It aims at reducing the output rate to less than 100 kHz. The Central Trigger Processor combines information from the calorimeter and muon trigger processors and makes the final Level-1-Accept decision. It is a central element in the timing setup of the experiment. Three aspects are considered in this article: the timing setup with respect to the Level-1 trigger, with respect to the expriment, and with respect to the world.

  9. The Slice Algorithm For Irreducible Decomposition of Monomial Ideals

    DEFF Research Database (Denmark)

    Roune, Bjarke Hammersholt

    2009-01-01

    Irreducible decomposition of monomial ideals has an increasing number of applications from biology to pure math. This paper presents the Slice Algorithm for computing irreducible decompositions, Alexander duals and socles of monomial ideals. The paper includes experiments showing good performance...

  10. Innovative application of virtual display technique in virtual museum

    Science.gov (United States)

    Zhang, Jiankang

    2017-09-01

    Virtual museum refers to display and simulate the functions of real museum on the Internet in the form of 3 Dimensions virtual reality by applying interactive programs. Based on Virtual Reality Modeling Language, virtual museum building and its effective interaction with the offline museum lie in making full use of 3 Dimensions panorama technique, virtual reality technique and augmented reality technique, and innovatively taking advantages of dynamic environment modeling technique, real-time 3 Dimensions graphics generating technique, system integration technique and other key virtual reality techniques to make sure the overall design of virtual museum.3 Dimensions panorama technique, also known as panoramic photography or virtual reality, is a technique based on static images of the reality. Virtual reality technique is a kind of computer simulation system which can create and experience the interactive 3 Dimensions dynamic visual world. Augmented reality, also known as mixed reality, is a technique which simulates and mixes the information (visual, sound, taste, touch, etc.) that is difficult for human to experience in reality. These technologies make virtual museum come true. It will not only bring better experience and convenience to the public, but also be conducive to improve the influence and cultural functions of the real museum.

  11. Comparison of MRI fast SPGR single slice scan and continuous dynamic scan in patients with obstructive sleep apnea-hypopnea syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xinyu [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: myginny2@sina.com; Yang Xue [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: yangxueqyfy@126.com; Hua Hui [Department of Otorhinolaryngology-Head and Neck Surgery, Medical School Hospital of Qingdao University, Qingdao (China)], E-mail: huahuisky@163.com; Chen Jingjing [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: chenjingjingsky@126.com

    2009-07-15

    Objective: To evaluate the application value of MRI fast SPGR single slice scan in patients with obstructive sleep apnea-hypopnea syndrome when comparing the images between fast SPGR single slice scan and continuous dynamic scan. Methods: Eighteen patients with obstructive sleep apnea-hypopnea syndrome were examined by fast SPGR single slice scan and continuous dynamic scan in turn. Fast SPGR single slice scans were conducted when the phases of apnea, inspiration and expiration appeared on the respiratory wave of the subjects. Fast SPGR continuous dynamic scans were conducted when the patients were awake and apneic. The scan planes were median sagittal plane and axial planes (the slice of middle part of palate, the slice of inferior part of palate, the slice of middle part of lingual root and the slice of 0.5 cm beneath the free margin of epiglottis). The obstructed sites and the cross-sectional areas of upper airway were compared between the two scan methods. Results: Seven cases showed complete obstruction at the narrowest sites of upper airway when apnea appeared; eleven cases showed marked decrease in cross-sectional areas at the narrowest sites compared with the areas when the patients were awake; two cases manifested multiple narrowness. The obstructed sites showed by the two scan methods were same. The difference of the cross-sectional areas of upper airway between the two scan methods was insignificant (P > 0.05). Conclusion: Fast SPGR single slice scan can accurately reflect the obstructed sites of upper airway when the breath breaks off and is the complementary method of continuous dynamic scan. Sometimes, single slice scan can replace continuous dynamic scan.

  12. Realistic Visualization of Virtual Views and Virtual Cinema

    DEFF Research Database (Denmark)

    Livatino, Salvatore

    2005-01-01

    Realistic Virtual View Visualization is a new field of research which has received increasing attention in recent years. It is strictly related to the increased popularity of virtual reality and the spread of its applications, among which virtual photography and cinematography. The use of computer...... generated characters, "virtual actors", in the motion picture production increases every day. While the most known computer graphics techniques have largely been adopted successfully in nowadays fictions, it still remains very challenging to implement virtual actors which would resemble, visually, human...... beings. Interestingly, film directors have been looking at the recent progress achieved by the research community in the field of realistic visualization of virtual views, and they have successfully implemented state of the art research approaches in their productions. An innovative concept...

  13. Three-dimensional electrode array for brain slice culture

    DEFF Research Database (Denmark)

    Vazquez Rodriguez, Patricia

    Multielektroder arrays (MEA) er rækker af elektroder mest i mikrometer størrelse, som er blevet brugt i stor omfang til at stimulere og måle elektrisk aktivitet fra neuronale netværker. Brug af disse for at analysere hjerne slices (hjerneskiver) kan give indsigt i interaktioner mellem neuroner, e...

  14. Virtual Trondheim: A Virtual Environment for Tourism and Education

    OpenAIRE

    Jose, Dawn Alphonse

    2015-01-01

    The purpose of this study is to investigate whether educational activities in tourism can be supported by virtual reality technologies, using virtual world frameworks. Settings of virtual world of SecondLife and a recent Virtual Reality technology known as Oculus Rift were used in the thesis work with the city of Trondheim as the main context. Theoretical studies on Virtual Reality systems were conducted and data for the research were obtained through empirical studies condu...

  15. Physical, Digital, and Hybrid Setups Supporting Card-Based Collaborative Design Ideation

    DEFF Research Database (Denmark)

    Lundqvist, Caroline Emilie; Klinkhammer, Daniel; Dalsgaard, Peter

    2018-01-01

    to supporting collaborative ideation? To answer this question, we present a study and analysis of three different implementations of a well-established collaborative ideation technique called Inspiration Card Workshop, with physical, digital, and hybrid setups. Each setup is evaluated in a controlled experiment...

  16. Radiotherapy for breast cancer: respiratory and set-up uncertainties

    International Nuclear Information System (INIS)

    Saliou, M.G.; Giraud, P.; Simon, L.; Fournier-Bidoz, N.; Fourquet, A.; Dendale, R.; Rosenwald, J.C.; Cosset, J.M.

    2005-01-01

    Adjuvant Radiotherapy has been shown to significantly reduce locoregional recurrence but this advantage is associated with increased cardiovascular and pulmonary morbidities. All uncertainties inherent to conformal radiation therapy must be identified in order to increase the precision of treatment; misestimation of these uncertainties increases the potential risk of geometrical misses with, as a consequence, under-dosage of the tumor and/or overdosage of healthy tissues. Geometric uncertainties due to respiratory movements or set-up errors are well known. Two strategies have been proposed to limit their effect: quantification of these uncertainties, which are then taken into account in the final calculation of safety margins and/or reduction of respiratory and set-up uncertainties by an efficient immobilization or gating systems. Measured on portal films with two tangential fields. CLD (central lung distance), defined as the distance between the deep field edge and the interior chest wall at the central axis, seems to be the best predictor of set-up uncertainties. Using CLD, estimated mean set-up errors from the literature are 3.8 and 3.2 mm for the systematic and random errors respectively. These depend partly on the type of immobilization device and could be reduced by the use of portal imaging systems. Furthermore, breast is mobile during respiration with motion amplitude as high as 0.8 to 10 mm in the anteroposterior direction. Respiratory gating techniques, currently on evaluation, have the potential to reduce effect of these movements. Each radiotherapy department should perform its own assessments and determine the geometric uncertainties with respect of the equipment used and its particular treatment practices. This paper is a review of the main geometric uncertainties in breast treatment, due to respiration and set-up, and solutions proposed to limit their impact. (author)

  17. Virtual Trackballs Revisited

    DEFF Research Database (Denmark)

    Henriksen, Knud; Sporring, Jon; Hornbæk, Kasper

    2004-01-01

    reviews and provides a mathematical foundation for virtual trackballs. The first, but still popular, virtual trackball was described by Chen et al. [CHECK END OF SENTENCE]. We show that the virtual trackball by Chen et al. does not rotate the object along the intended great circular arc on the virtual...... trackball and we give a correction. Another popular virtual trackball is Shoemake's quaternion implementation [CHECK END OF SENTENCE], which we show to be a special case of the virtual trackball by Chen et al.. Shoemake extends the scope of the virtual trackball to the full screen. Unfortunately, Shoemake......'s virtual trackball is inhomogeneous and discontinuous with consequences for usability. Finally, we review Bell's virtual trackball [CHECK END OF SENTENCE] and discuss studies of the usability of virtual trackballs....

  18. Methods to induce primary and secondary traumatic damage in organotypic hippocampal slice cultures.

    Science.gov (United States)

    Adamchik, Y; Frantseva, M V; Weisspapir, M; Carlen, P L; Perez Velazquez, J L

    2000-04-01

    Organotypic brain slice cultures have been used in a variety of studies on neurodegenerative processes [K.M. Abdel-Hamid, M. Tymianski, Mechanisms and effects of intracellular calcium buffering on neuronal survival in organotypic hippocampal cultures exposed to anoxia/aglycemia or to excitotoxins, J. Neurosci. 17, 1997, pp. 3538-3553; D.W. Newell, A. Barth, V. Papermaster, A.T. Malouf, Glutamate and non-glutamate receptor mediated toxicity caused by oxygen and glucose deprivation in organotypic hippocampal cultures, J. Neurosci. 15, 1995, pp. 7702-7711; J.L. Perez Velazquez, M.V. Frantseva, P.L. Carlen, In vitro ischemia promotes glutamate mediated free radical generation and intracellular calcium accumulation in pyramidal neurons of cultured hippocampal slices, J. Neurosci. 23, 1997, pp. 9085-9094; L. Stoppini, L.A. Buchs, D. Muller, A simple method for organotypic cultures of nervous tissue, J. Neurosci. Methods 37, 1991, pp. 173-182; R.C. Tasker, J.T. Coyle, J.J. Vornov, The regional vulnerability to hypoglycemia induced neurotoxicity in organotypic hippocampal culture: protection by early tetrodotoxin or delayed MK 801, J. Neurosci. 12, 1992, pp. 4298-4308.]. We describe two methods to induce traumatic cell damage in hippocampal organotypic cultures. Primary trauma injury was achieved by rolling a stainless steel cylinder (0.9 g) on the organotypic slices. Secondary injury was followed after dropping a weight (0.137 g) on a localised area of the organotypic slice, from a height of 2 mm. The time course and extent of cell death were determined by measuring the fluorescence of the viability indicator propidium iodide (PI) at several time points after the injury. The initial localised impact damage spread 24 and 67 h after injury, cell death being 25% and 54%, respectively, when slices were kept at 37 degrees C. To validate these methods as models to assess neuroprotective strategies, similar insults were applied to slices at relatively low temperatures (30

  19. Personal Virtual Libraries

    Science.gov (United States)

    Pappas, Marjorie L.

    2004-01-01

    Virtual libraries are becoming more and more common. Most states have a virtual library. A growing number of public libraries have a virtual presence on the Web. Virtual libraries are a growing addition to school library media collections. The next logical step would be personal virtual libraries. A personal virtual library (PVL) is a collection…

  20. Slaw extracted proton beam formation and monitoring for the ''QUARTZ'' setup

    International Nuclear Information System (INIS)

    Bushnin, Yu.B.; Gres', V.N.; Davydenko, Yu.P.

    1982-01-01

    The version of optical mode of the beam channel providing with simultaneous operating the experimental setups FODS and ''QUARTZ'' at consecutive usage of the slow extracted proton beam is reported. The ''QUARTZ'' setup beam diagnostics system comprises two subsystems: for measuring beam profile beam timing structure and beam intensity and operates in the beam extraction duration from 20 ns to few seconds at beam intensity from 10 10 to 5x10 12 protons/pulse. The ''QUARTZ'' setup represents a focusing crystal-diffraction spectrometer with 5-meter focal distance and Ge(Li) special construction detector. High efficiency target is applied in the setup. The ''QUARTZ'' setup is designed for studying exotic atoms produced by negative charged heavy particles (π, K, μ, P tilde) and atomic nuclei. Precise energy measurement of X ray transitions in such atoms is performed. For measuring beam geometric parameters 32-channel secondary emission chambers are used. As detector of beam intensity and timing structure of slow extracted beam the secondary emission chamber is employed. The principle circuit of current integrator is given. As data transmission line a 50-pair telephone cable is used. Information conversion into digital form and its subsequent processing is performed in the CAMAC system and the SM-3 computer. The proton beam full intensity measuring system provides with accuracy not worse than +-4.5% in the 10 10 -10 12 proton/sec range. The implemented optical mode of the beam channel and proton beam monitoring system permitted to begin fulfillment of the experimental program on the ''QUARTZ'' setup

  1. A novel method for oxygen glucose deprivation model in organotypic spinal cord slices.

    Science.gov (United States)

    Liu, Jing-Jie; Ding, Xiao-Yan; Xiang, Li; Zhao, Feng; Huang, Sheng-Li

    2017-10-01

    This study aimed to establish a model to closely mimic spinal cord hypoxic-ischemic injury with high production and high reproducibility. Fourteen-day cultured organotypic spinal cord slices were divided into 4 groups: control (Ctrl), oxygen glucose deprived for 30min (OGD 30min), OGD 60min, and OGD 120min. The Ctrl slices were incubated with 1ml propidium iodide (PI) solution (5μg/ml) for 30min. The OGD groups were incubated with 1ml glucose-free DMEM/F12 medium and 5μl PI solution (1mg/ml) for 30min, 60min and 120min, respectively. Positive control slice was fixed by 4% paraformaldehyde for 20min. The culture medium in each group was then collected and the Lactate Dehydrogenase (LDH) level in the medium was tested using Multi-Analyte ELISArray kits. Structure and refraction of the spinal cord slices were observed by light microscope. Fluorescence intensity of PI was examined by fluorescence microscopy and was tested by IPP Software. Morphology of astrocytes was observed by immunofluorescence histochemistry. Caspase 3 and caspase 3 active in different groups were tested by Western blot. In the OGD groups, the refraction of spinal cord slices decreased and the structure was unclear. The changes of refraction and structure in the OGD 120min group were similar to that in the positive control slice. Astrocyte morphology changed significantly. With the increase of OGD time, processes became thick and twisted, and nuclear condensations became more apparent. Obvious changes in morphology were observed in the OGD 60min group, and normal morphology disappeared in the OGD 120min group. Fluorescence intensity of PI increased along with the extension of OGD time. The difference was significant between 30min and 60min, but not significant between 60min and 120min. The intensity at OGD 120min was close to that in the positive control. Compare with the Ctrl group, the OGD groups had significantly higher LDH levels and caspase 3 active/caspase 3 ratios. The values increased

  2. A Unified Approach to Diffusion Direction Sensitive Slice Registration and 3-D DTI Reconstruction From Moving Fetal Brain Anatomy

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann; Seshamani, Sharmishtaa; Kroenke, Christopher

    2014-01-01

    to the underlying anatomy. Previous image registration techniques have been described to estimate the between slice fetal head motion, allowing the reconstruction of 3D a diffusion estimate on a regular grid using interpolation. We propose Approach to Unified Diffusion Sensitive Slice Alignment and Reconstruction...... (AUDiSSAR) that explicitly formulates a process for diffusion direction sensitive DW-slice-to-DTI-volume alignment. This also incorporates image resolution modeling to iteratively deconvolve the effects of the imaging point spread function using the multiple views provided by thick slices acquired...

  3. Measurement setup at light source operational: Milestone M4.3

    CERN Document Server

    Perez, Francis

    2016-01-01

    The design of the experimental setup for the measurements of the FCC-hh beam screen prototype to be installed at the ANKA lightsource has been completed and the alignment strategy and procedure has been validated by the CERN and KIT teams. In this report, a complete description of the setup and the program of measurements under different operation conditions is presented.

  4. Recent developments in multi-wire fixed abrasive slicing technique (FAST). [for low cost silicon wafer production from ingots

    Science.gov (United States)

    Schmid, F.; Khattak, C. P.; Smith, M. B.; Lynch, L. D.

    1982-01-01

    Slicing is an important processing step for all technologies based on the use of ingots. A comparison of the economics of three slicing techniques shows that the fixed abrasive slicing technique (FAST) is superior to the internal diameter (ID) and the multiblade slurry (MBS) techniques. Factors affecting contact length are discussed, taking into account kerf width, rocking angle, ingot size, and surface speed. Aspects of blade development are also considered. A high concentration of diamonds on wire has been obtained in wire packs usd for FAST slicing. The material removal rate was found to be directly proportional to the pressure at the diamond tips.

  5. Wireless virtualization

    CERN Document Server

    Wen, Heming; Le-Ngoc, Tho

    2013-01-01

    This SpringerBriefs is an overview of the emerging field of wireless access and mobile network virtualization. It provides a clear and relevant picture of the current virtualization trends in wireless technologies by summarizing and comparing different architectures, techniques and technologies applicable to a future virtualized wireless network infrastructure. The readers are exposed to a short walkthrough of the future Internet initiative and network virtualization technologies in order to understand the potential role of wireless virtualization in the broader context of next-generation ubiq

  6. Pragmatic setup for bioparticle responses by dielectrophoresis for resource limited environment application

    Science.gov (United States)

    Ali, Mohd Anuar Md; Yeop Majlis, Burhanuddin; Kayani, Aminuddin Ahmad

    2017-12-01

    Various dielectrophoretic responses of bioparticles, including cell-chain, spinning, rotation and clustering, are of high interest in the field due to their benefit into application for biomedical and clinical implementation potential. Numerous attempts using sophisticated equipment setup have been studied to perform those dielectrophoretic responses, however, for development into resource limited environment application, such as portable, sustainable and environmental friendly diagnostic tools, establishment of pragmatic setup using standard, non-sophisticated and low-cost equipment is of important task. Here we show the advantages in the judicious design optimization of tip microelectrode, also with selection of suspending medium and optimization of electric signal configuration in establishing setup that can promote the aforementioned dielectrophoretic responses within standard equipments, i.e. pragmatic setup.

  7. Experiment Setup for Focused Learning of Advanced Servo Control of DC-motors

    Directory of Open Access Journals (Sweden)

    Dag A. H. Samuelsen

    2012-02-01

    Full Text Available Remote laboratories are normally developed for giving students and others remote access to physical laboratory facilities. In contradiction to this, the main objective of the setup presented in this paper is to create a controlled environment where unwanted side activities like hardware setup, driver problems, troubleshooting faulty components, and struggles with special software for configuring DSP systems, are removed as much as possible, in order for the students to have their full focus on the tasks that is considered relevant for the module: modeling of non-linear systems, synthetisation of controllers, and stability and performance analysis. A secondary objective is to significantly reduce the setup and maintenance cost associated with complex laboratory setups involving DSPs and expensive hardware.

  8. X-radiography of slices of the Allende Meteorite

    Science.gov (United States)

    Smith, M. J.; Anderson, J. B.; Heymann, D.

    1984-01-01

    A 2.2 kg fragment of the Allende Meteorite was derinded and sliced by bandsawing. Several X-radiographs were made of all slices. The following features are resolved: grains of blocky troilite (bright spots), troilite rimmed chondrules (bright halos), chondrules with central vugs (dim halos), white aggregates (dark patches), and dark inclusions (medium dark patches). The number of FeS grains larger than about 0.5 mm is one per 6 + or - 1 gram of this fragment. Their concentration appears to be uniform at the 1 kg weight level, but is not uniform at the 100 g level. The number of FeS rimmed chondrules is one per 10 g. Their concentration is also nonuniform at the 100 g weight level. The number of white aggregates is roughly one per 20 g. These disc shaped objects show a distinct preferred orientation of the axis orthogonal to the plane of the disc. Chondrules with central vugs are numerous. Linear and curved arrays of chondrules, up to a few cm long, were observed. An interpretation of the observed features is given.

  9. Evaluating the influence of setup uncertainties on treatment planning for focal liver tumors

    International Nuclear Information System (INIS)

    Balter, J.M.; Brock, K.K.; Lam, K.L.; Dawson, L.A.; McShan, D.L.; Ten Haken, R.K.

    2001-01-01

    Purpose: A mechanism has been developed to evaluate the influence of systematic and random setup variations on dose during treatment planning. The information available for studying these factors shifts from population-based models towards patient-specific data as treatment progresses and setup measurements for an individual patient become available. This study evaluates the influence of population as well as patient-specific setup distributions on treatment plans for focal liver tumors. Materials and Methods: 8 patients with focal liver tumors were treated on a protocol that involved online setup measurement and adjustment, as well as ventilatory immobilization. Summary statistics from these treatments yielded individual and population distributions of position at initial setup for each fraction as well as after setup adjustment. A convolution model for evaluation of the influence of random setup variation on calculated dose distributions has been previously described and investigated for application to focal liver radiotherapy by our department. Individual patient doses based on initial setup positions were calculated by applying the measured systematic offset to the initial treatment plan, and then convolving the calculated dose distribution with an anisotropic probability distribution function representing the individual patient's random variations. A separate calculation with no offset and convolution using population averaged random variations was performed. Individual beam apertures were then adjusted to provide plans that ensured proper dose to the clinical target volume (CTV) following convolution with population distributions prior to and following setup adjustment. Results: Input distributions comprised 262 position measurements. Individual patient setup distributions for the course of treatment had systematic offsets ranging from (σ) 1.1 to 4.1 mm (LR), -2.0 to 1.4 mm (AP), and 5.6 to 1.7 mm (IS). Individual random setup variations ranged from 2.5 to 5

  10. Virtual Reality Glasses and "Eye-Hands Blind Technique" for Microsurgical Training in Neurosurgery.

    Science.gov (United States)

    Choque-Velasquez, Joham; Colasanti, Roberto; Collan, Juhani; Kinnunen, Riina; Rezai Jahromi, Behnam; Hernesniemi, Juha

    2018-04-01

    Microsurgical skills and eye-hand coordination need continuous training to be developed and refined. However, well-equipped microsurgical laboratories are not so widespread as their setup is expensive. Herein, we present a novel microsurgical training system that requires a high-resolution personal computer screen, smartphones, and virtual reality glasses. A smartphone placed on a holder at a height of about 15-20 cm from the surgical target field is used as the webcam of the computer. A specific software is used to duplicate the video camera image. The video may be transferred from the computer to another smartphone, which may be connected to virtual reality glasses. Using the previously described training model, we progressively performed more and more complex microsurgical exercises. It did not take long to set up our system, thus saving time for the training sessions. Our proposed training model may represent an affordable and efficient system to improve eye-hand coordination and dexterity in using not only the operating microscope but also endoscopes and exoscopes. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. An optimised set-up for total reflection particle induced X-ray emission

    International Nuclear Information System (INIS)

    Kan, J.A. van; Vis, R.D.

    1997-01-01

    MeV proton beams at small angles of incidence (0-35 mrad) are used to analyse trace elements on flat surfaces such as Si wafers or quartz substrates. In these experiments, the particle induced X-ray emission (PIXE) signal is used in a new optimized set-up. This set-up is constructed in such a way that the X-ray detector can reach very large solid angles, larger than 1 sr. Use of these large detector solid angles, combined with the reduction of bremsstrahlung background, affords limits of detection (LOD) of the order of 10 10 at cm -2 using total reflection particle induced X-ray emission (TPIXE). The LODs from earlier TPIXE measurements in a non-optimized set-up are used to estimate LODs in the new TPIXE set-up. Si wafers with low surface concentrations of V, Ni, Cu and Ag are used as standards to calibrate the LODs found with this set-up. The metal concentrations are determined by total reflection X-ray fluorescence (TXRF). The TPIXE measurements are compared with TXRF measurements on the same wafers. (Author)

  12. Virtual colonoscopy

    Science.gov (United States)

    Colonoscopy - virtual; CT colonography; Computed tomographic colonography; Colography - virtual ... Differences between virtual and conventional colonoscopy include: VC can view the colon from many different angles. This is not as easy ...

  13. Eye-in-Hand Manipulation for Remote Handling: Experimental Setup

    Science.gov (United States)

    Niu, Longchuan; Suominen, Olli; Aref, Mohammad M.; Mattila, Jouni; Ruiz, Emilio; Esque, Salvador

    2018-03-01

    A prototype for eye-in-hand manipulation in the context of remote handling in the International Thermonuclear Experimental Reactor (ITER)1 is presented in this paper. The setup consists of an industrial robot manipulator with a modified open control architecture and equipped with a pair of stereoscopic cameras, a force/torque sensor, and pneumatic tools. It is controlled through a haptic device in a mock-up environment. The industrial robot controller has been replaced by a single industrial PC running Xenomai that has a real-time connection to both the robot controller and another Linux PC running as the controller for the haptic device. The new remote handling control environment enables further development of advanced control schemes for autonomous and semi-autonomous manipulation tasks. This setup benefits from a stereovision system for accurate tracking of the target objects with irregular shapes. The overall environmental setup successfully demonstrates the required robustness and precision that remote handling tasks need.

  14. Validity test of design calculations of a PGNAA setup

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Garwan, M.A.

    2004-01-01

    A rectangular moderator has been designed for the prompt gamma ray neutron activation analysis (PGNAA) setup at King Fahd University of Petroleum and Minerals (KFUPM) to analyze Portland cement samples. The design of the moderator assembly was obtained using Monte Carlo calculations. The design calculations of the new rectangular moderator of the KFUPM PGNAA setup have been verified experimentally through prompt gamma ray yield measurement as a function of the front moderator thickness. In this study the yield of the 3.54 and 4.94 MeV prompt gamma rays from silicon in a soil sample was measured as a function of thickness of the front moderator of the rectangular moderator. The experimental results were compared with the results of the Monte Carlo simulations. A good agreement has been achieved between the experimental results and the results of the calculations. The experimental results have provided useful information about the PGNAA setup performance, neutron moderation, and gamma ray attenuation in the PGNAA sample

  15. Virtual Exploratories

    DEFF Research Database (Denmark)

    Jensen, Sisse Siggaard

    2006-01-01

    -systems, the paper introduces the designing strategy referred to as virtual exploratories. Some of the advanced virtual worlds may inspire the design of such provoking and challenging virtual exploratories, and especially the Massively Multi-User Online Role-Playing Games (MMORPGS). However, if we have to learn from...... the design and activity of the advanced virtual worlds and role-playing games, then the empirical research on the actors’ activity, while they are acting, is an important precondition to it. A step towards the conception of such a designing strategy for virtual exploratories is currently pursued....... [1] The research project: Actors and Avatars Communicating in Virtual Worlds – an Empirical Analysis of Actors’ Sense-making Strategies When Based on a Communication Theoretical Approach’ (2006-2007) is supported...

  16. Analysis of Prostate Patient Setup and Tracking Data: Potential Intervention Strategies

    International Nuclear Information System (INIS)

    Su Zhong; Zhang Lisha; Murphy, Martin; Williamson, Jeffrey

    2011-01-01

    Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data: the deviation threshold and period. The related planning target volume margins, time costs, and prostate position 'fluctuation' were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for ≥91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the

  17. Long-term brain slice culturing in a microfluidic platform

    DEFF Research Database (Denmark)

    Vedarethinam, Indumathi; Avaliani, N.; Tønnesen, J.

    2011-01-01

    In this work, we present the development of a transparent poly(methyl methacrylate) (PMMA) based microfluidic culture system for handling long-term brain slice cultures independent of an incubator. The different stages of system development have been validated by culturing GFP producing brain sli...

  18. A sandwich-like differential B-dot based on EACVD polycrystalline diamond slice

    Science.gov (United States)

    Xu, P.; Yu, Y.; Xu, L.; Zhou, H. Y.; Qiu, C. J.

    2018-06-01

    In this article, we present a method of mass production of a standardized high-performance differential B-dot magnetic probe together with the magnetic field measurement in a pulsed current device with the current up to hundreds of kilo-Amperes. A polycrystalline diamond slice produced in an Electron Assisted Chemical Vapor Deposition device is used as the base and insulating material to imprint two symmetric differential loops for the magnetic field measurement. The SP3 carbon bond in the cubic lattice structure of diamond is confirmed by Raman spectra. The thickness of this slice is 20 μm. A gold loop is imprinted onto each surface of the slice by using the photolithography technique. The inner diameter, width, and thickness of each loop are 0.8 mm, 50 μm, and 1 μm, respectively. It provides a way of measuring the pulsed magnetic field with a high spatial and temporal resolution, especially in limited space. This differential magnetic probe has demonstrated a very good common-mode rejection rate through the pulsed magnetic field measurement.

  19. Application of gamma irradiation for the microbiological safety of sliced cheddar cheese

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Song, Beom Seok; Kim, Jae Hun; Choi, Jong Ill; Lee, Ju Woon; Byun, Myung Woo [Radiation Research Center for Innovative Technology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Jo, Cheo Run [Dept. of Animal Science and Biotechnology, Chungnam National University, Daejeon (Korea, Republic of)

    2007-05-15

    This study was conducted to establish the microbiological safety of sliced cheddar cheese with gamma irradiation. Total aerobic bacteria was 2.50 Log CFUg-1 in non-irradiated sample. No viable cells were observed in the gamma-irradiated at 1 kGy and over. D10 value for Listeria monocytogenes and Staphylococcus aureus inoculated in sliced cheddar cheese were 0.64 and 0.54 kGy, respectively. TBARS (2-thiobarbituric acid reactive substances) values were increased as irradiation dose was increased, but there was no significant difference between nonirradiated and irradiated samples at 1 kGy. Sensory evaluation showed there was no significant difference between samples irradiated at 1 kGy and non-irradiated in respect of color, odor, overall acceptability. Theses results indicated that gamma irradiation at 1 kGy was considered to be an effective treatment to ensure the microbiological safety of sliced cheddar cheese with minimal change of sensory, even though further studies should be investigated to reduce the deterioration of sensory quality induced by gamma irradiation.

  20. A slice through a prototype LHC bending magnet

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This slice through a prototype LHC magnet clearly shows the superconducting cable in several blocks around the central hole – the beam pipe in which the LHC’s accelerated beams will travel. Magnet design is crucial to the LHC’s success and this sample is among the first to be built to the final cable configuration.

  1. Setup verification in stereotactic radiotherapy using digitally reconstructed radiograph (DRR)

    International Nuclear Information System (INIS)

    Cho, Byung Chul; Oh, Do Hoon; Bae, Hoon Sik

    1999-01-01

    To develop a method for verifying a treatment setup in stereotactic radiotherapy by matching portal images to DRRs. Four pairs of orthogonal portal images of one patient immobilized by a thermoplastic mast frame for fractionated stereotactic radiotherapy were compared with DRRs. Portal images are obtained in AP (anterior/posterior) and lateral directions with a target localizer box containing fiducial markers attached to a stereotactic frame. DRRs superimposed over a planned isocenter and fiducial markers are printed out on transparent films. And then, they were overlaid over orthogonal portal images by matching anatomical structures. From three different kind of objects (isocenter, fiducial markers, anatomical structure) on DRRs and portal images, the displacement error between anatomical structure and isocenters (overall setup error), and the displacement error between fiducial markers and isocenters (localization error)were measured. Localization errors were 1.5±0.3 mm (lateral), and immobilization errors were 1.9±0.5 mm (AP), 1.9±0.4 mm (lateral). In addition, overall setup errors were 1.6±0.9 mm (AP), 1.3±0.4 mm(lateral). From these orthogonal displacement errors, maximum 3D displacement errors(√(ΔAP) 2 +(ΔLat) 2 ) were found to be 1.7±0.4 mm for localization, 2.6±0.6 mm for immobilization, and 2.3±0.7 mm for overall treatment setup. By comparing orthogonal portal images with DRRs, we find out that it is possible to verify treatment setup directly in stereotactic radiotherapy

  2. X-band EPR setup with THz light excitation of Novosibirsk Free Electron Laser: Goals, means, useful extras.

    Science.gov (United States)

    Veber, Sergey L; Tumanov, Sergey V; Fursova, Elena Yu; Shevchenko, Oleg A; Getmanov, Yaroslav V; Scheglov, Mikhail A; Kubarev, Vitaly V; Shevchenko, Daria A; Gorbachev, Iaroslav I; Salikova, Tatiana V; Kulipanov, Gennady N; Ovcharenko, Victor I; Fedin, Matvey V

    2018-03-01

    Electron Paramagnetic Resonance (EPR) station at the Novosibirsk Free Electron Laser (NovoFEL) user facility is described. It is based on X-band (∼9 GHz) EPR spectrometer and operates in both Continuous Wave (CW) and Time-Resolved (TR) modes, each allowing detection of either direct or indirect influence of high-power NovoFEL light (THz and mid-IR) on the spin system under study. The optics components including two parabolic mirrors, shutters, optical chopper and multimodal waveguide allow the light of NovoFEL to be directly fed into the EPR resonator. Characteristics of the NovoFEL radiation, the transmission and polarization-retaining properties of the waveguide used in EPR experiments are presented. The types of proposed experiments accessible using this setup are sketched. In most practical cases the high-power radiation applied to the sample induces its rapid temperature increase (T-jump), which is best visible in TR mode. Although such influence is a by-product of THz radiation, this thermal effect is controllable and can deliberately be used to induce and measure transient signals of arbitrary samples. The advantage of tunable THz radiation is the absence of photo-induced processes in the sample and its high penetration ability, allowing fast heating of a large portion of virtually any sample and inducing intense transients. Such T-jump TR EPR spectroscopy with THz pulses has been previewed for the two test samples, being a useful supplement for the main goals of the created setup. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Modulation of methylmercury uptake by methionine: Prevention of mitochondrial dysfunction in rat liver slices by a mimicry mechanism

    International Nuclear Information System (INIS)

    Roos, Daniel Henrique; Puntel, Robson Luiz; Farina, Marcelo; Aschner, Michael; Bohrer, Denise; Rocha, Joao Batista T.; Vargas Barbosa, Nilda B. de

    2011-01-01

    Methylmercury (MeHg) is an ubiquitous environmental pollutant which is transported into the mammalian cells when present as the methylmercury-cysteine conjugate (MeHg-Cys). With special emphasis on hepatic cells, due to their particular propensity to accumulate an appreciable amount of Hg after exposure to MeHg, this study was performed to evaluate the effects of methionine (Met) on Hg uptake, reactive species (RS) formation, oxygen consumption and mitochondrial function/cellular viability in both liver slices and mitochondria isolated from these slices, after exposure to MeHg or the MeHg-Cys complex. The liver slices were pre-treated with Met (250 μM) 15 min before being exposed to MeHg (25 μM) or MeHg-Cys (25 μM each) for 30 min at 37 o C. The treatment with MeHg caused a significant increase in the Hg concentration in both liver slices and mitochondria isolated from liver slices. Moreover, the Hg uptake was higher in the group exposed to the MeHg-Cys complex. In the DCF (dichlorofluorescein) assay, the exposure to MeHg and MeHg-Cys produced a significant increase in DFC reactive species (DFC-RS) formation only in the mitochondria isolated from liver slices. As observed with Hg uptake, DFC-RS levels were significantly higher in the mitochondria treated with the MeHg-Cys complex compared to MeHg alone. MeHg exposure also caused a marked decrease in the oxygen consumption of liver slices when compared to the control group, and this effect was more pronounced in the liver slices treated with the MeHg-Cys complex. Similarly, the loss of mitochondrial activity/cell viability was greater in liver slices exposed to the MeHg-Cys complex when compared to slices treated only with MeHg. In all studied parameters, Met pre-treatment was effective in preventing the MeHg- and/or MeHg-Cys-induced toxicity in both liver slices and mitochondria. Part of the protection afforded by Met against MeHg may be related to a direct interaction with MeHg or to the competition of Met with

  4. Single-slice epicardial fat area measurement. Do we need to measure the total epicardial fat volume?

    International Nuclear Information System (INIS)

    Oyama, Noriko; Goto, Daisuke; Ito, Yoichi M.

    2011-01-01

    The aim of this study was to assess a method for measuring epicardial fat volume (EFV) by means of a single-slice area measurement. We investigated the relation between a single-slice fat area measurement and total EFV. A series of 72 consecutive patients (ages 65±11 years; 36 men) who had undergone cardiac computed tomography (CT) on a 64-slice multidetector scanner with prospective electrocardiographic triggering were retrospectively reviewed. Pixels in the pericardium with a density range from -230 to -30 Hounsfield units were considered fat, giving the per-slice epicardial fat area (EFA). The EFV was estimated by the summation of EFAs multiplied by the slice thickness. We investigated the relation between total EFV and each EFA. EFAs measured at several anatomical landmarks - right pulmonary artery, origins of the left main coronary artery, right coronary artery, coronary sinus - all correlated with the EFV (r=0.77-0.92). The EFA at the LMCA level was highly reproducible and showed an excellent correlation with the EFV (r=0.92). The EFA is significantly correlated with the EFV. The EFA is a simple, quick method for representing the time-consuming EFV, which has been used as a predictive indicator of cardiovascular diseases. (author)

  5. Constructing a Computer Model of the Human Eye Based on Tissue Slice Images

    OpenAIRE

    Dai, Peishan; Wang, Boliang; Bao, Chunbo; Ju, Ying

    2010-01-01

    Computer simulation of the biomechanical and biological heat transfer in ophthalmology greatly relies on having a reliable computer model of the human eye. This paper proposes a novel method on the construction of a geometric model of the human eye based on tissue slice images. Slice images were obtained from an in vitro Chinese human eye through an embryo specimen processing methods. A level set algorithm was used to extract contour points of eye tissues while a principle component analysi...

  6. Sensitivity-based virtual fields for the non-linear virtual fields method

    Science.gov (United States)

    Marek, Aleksander; Davis, Frances M.; Pierron, Fabrice

    2017-09-01

    The virtual fields method is an approach to inversely identify material parameters using full-field deformation data. In this manuscript, a new set of automatically-defined virtual fields for non-linear constitutive models has been proposed. These new sensitivity-based virtual fields reduce the influence of noise on the parameter identification. The sensitivity-based virtual fields were applied to a numerical example involving small strain plasticity; however, the general formulation derived for these virtual fields is applicable to any non-linear constitutive model. To quantify the improvement offered by these new virtual fields, they were compared with stiffness-based and manually defined virtual fields. The proposed sensitivity-based virtual fields were consistently able to identify plastic model parameters and outperform the stiffness-based and manually defined virtual fields when the data was corrupted by noise.

  7. GDNF and neublastin protect against NMDA-induced excitotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Bonde, C; Kristensen, B W; Blaabjerg, M

    2000-01-01

    -producing HiB5 cells, were added to slice cultures I h before exposure to 10 microM NMDA for 48h. Neuronal cell death was monitored, before and during the NMDA exposure, by densitometric measurements of propidium iodide (PI) uptake and loss of Nissl staining. Both the addition of rhGDNF and NBN......The potential neuroprotective effects of glial cell line-derived neurotrophic factor (GDNF) and neublastin (NBN) against NMDA-induced excitotoxicity were examined in hippocampal brain slice cultures. Recombinant human GDNF (25-100 ng/ ml) or NBN, in medium conditioned by growth of transfected, NBN...

  8. On virtual displacement and virtual work in Lagrangian dynamics

    International Nuclear Information System (INIS)

    Ray, Subhankar; Shamanna, J

    2006-01-01

    The confusion and ambiguity encountered by students in understanding virtual displacement and virtual work is discussed in this paper. A definition of virtual displacement is presented that allows one to express them explicitly for holonomic (velocity independent), non-holonomic (velocity dependent), scleronomous (time independent) and rheonomous (time dependent) constraints. It is observed that for holonomic, scleronomous constraints, the virtual displacements are the displacements allowed by the constraints. However, this is not so for a general class of constraints. For simple physical systems, it is shown that the work done by the constraint forces on virtual displacements is zero. This motivates Lagrange's extension of d'Alembert's principle to a system of particles in constrained motion. However, a similar zero work principle does not hold for the allowed displacements. It is also demonstrated that d'Alembert's principle of zero virtual work is necessary for the solvability of a constrained mechanical problem. We identify this special class of constraints, physically realized and solvable, as the ideal constraints. The concept of virtual displacement and the principle of zero virtual work by constraint forces are central to both Lagrange's method of undetermined multipliers and Lagrange's equations in generalized coordinates

  9. Virtual Reality

    Science.gov (United States)

    1993-04-01

    until exhausted. SECURITY CLASSIFICATION OF THIS PAGE All other editions are obsolete. UNCLASSIFIED " VIRTUAL REALITY JAMES F. DAILEY, LIEUTENANT COLONEL...US" This paper reviews the exciting field of virtual reality . The author describes the basic concepts of virtual reality and finds that its numerous...potential benefits to society could revolutionize everyday life. The various components that make up a virtual reality system are described in detail

  10. Framework for Virtual Cognitive Experiment in Virtual Geographic Environments

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    2018-01-01

    Full Text Available Virtual Geographic Environment Cognition is the attempt to understand the human cognition of surface features, geographic processes, and human behaviour, as well as their relationships in the real world. From the perspective of human cognition behaviour analysis and simulation, previous work in Virtual Geographic Environments (VGEs has focused mostly on representing and simulating the real world to create an ‘interpretive’ virtual world and improve an individual’s active cognition. In terms of reactive cognition, building a user ‘evaluative’ environment in a complex virtual experiment is a necessary yet challenging task. This paper discusses the outlook of VGEs and proposes a framework for virtual cognitive experiments. The framework not only employs immersive virtual environment technology to create a realistic virtual world but also involves a responsive mechanism to record the user’s cognitive activities during the experiment. Based on the framework, this paper presents two potential implementation methods: first, training a deep learning model with several hundred thousand street view images scored by online volunteers, with further analysis of which visual factors produce a sense of safety for the individual, and second, creating an immersive virtual environment and Electroencephalogram (EEG-based experimental paradigm to both record and analyse the brain activity of a user and explore what type of virtual environment is more suitable and comfortable. Finally, we present some preliminary findings based on the first method.

  11. Measurements of operator performance - an experimental setup

    International Nuclear Information System (INIS)

    Netland, K.

    1980-01-01

    The human has to be considered as an important element in a process control system, even if the degree of automation is extremely high. Other elements, e.g. computer, displays, etc., can to a large extent be described and quantified. The human (operator), is difficult to describe in a precise way, and it is just as difficult to predict his thinking and acting in a control room environment. Many factors influence his performance, such as: experience, motivation, level of knowledge, training, control environment, job organization, etc. These factors have to a certain degree to be described before guidelines for design of the man-process interfaces and the control room layout can be developed. For decades, the psychological science has obtained knowledge of the human mind and behaviour. This knowledge should have the potential of a positive input on our effort to describe the factors influencing the operator performance. Even if the human is complex, a better understanding of his thinking and acting, and a more precise description of the factors influencing his performance can be obtained. At OECD Halden Reactor Project an experimental set-up for such studies has been developed and implemented in the computer laboratory. The present set-up includes elements as a computer- and display-based control room, a simulator representing a nuclear power plant, training programme for the subjects, and methods for the experiments. Set-up modules allow reconfiguration of experiments. (orig./HP)

  12. A Modernized UDM-600 Dynamometer-Based Setup for the Cutting Force Measurement

    Directory of Open Access Journals (Sweden)

    Ya. I. Shuliak

    2016-01-01

    Full Text Available The article considers development of a modernized UDM-600 dynamometer-based setup for measuring the cutting force components. Modernization of existing equipment to improve the method of recording the cutting force components in the automated mode is of relevance. The measuring setup allows recording the cutting force components in turning and milling, as well as the axial force and the torque in the drilling and milling operations.The article presents a block diagram and a schematic diagram of the setup to measure the cutting force components, and describes a basic principle of measuring units within the modernized setup. The developed setup uses a half-bridge strain gauge measuring circuit to record the cutting forces. To enhance the measuring circuit output voltage is used a 16-channel amplifier of LA-UN16 model with a discretely adjustable gain. To record and process electrical signals is used a data acquisition device of NI USB-6009 model, which enables transmitting the received data to a PC via USB-interface. The data acquisition device has a built-in stabilized DC power supply that is used to power the strain gauge bridges. A developed schematic diagram of the measuring setup allows us to realize this measuring device and implement its modernization.Final processing of recorded data is provided through the software developed in visual programming environment LabVIEW 9.0. The program allows us to show the real-time measuring values of the cutting force components graphically and to record the taken data to a text file.The measuring setup modernization enabled increasing measurement accuracy and reducing time for processing and analysis of experimental data obtained when measuring the cutting force components. The MT2 Department of BMSTU uses it in education and research activities and in experimental efforts and laboratory classes.

  13. Production Planning of a Failure-Prone Manufacturing System under Different Setup Scenarios

    Directory of Open Access Journals (Sweden)

    Guy-Richard Kibouka

    2016-01-01

    Full Text Available This paper presents a control problem for the optimization of the production and setup activities of an industrial system operating in an uncertain environment. This system is subject to random disturbances (breakdowns and repairs. These disturbances can engender stock shortages. The considered industrial system represents a well-known production context in industry and consists of a machine producing two types of products. In order to switch production from one product type to another, a time factor and a reconfiguration cost for the machine are associated with the setup activities. The parts production rates and the setup strategies are the decision variables which influence the inventory and the capacity of the system. The objective of the study is to find the production and setup policies which minimize the setup and inventory costs, as well as those associated with shortages. A modeling approach based on stochastic optimal control theory and a numerical algorithm used to solve the obtained optimality conditions are presented. The contribution of the paper, for industrial systems not studied in the literature, is illustrated through a numerical example and a comparative study.

  14. Scintillation forward spectrometer of the SPHERE setup

    International Nuclear Information System (INIS)

    Anisimov, Yu.S.; Afanas'ev, S.V.; Bondarev, V.K.

    1991-01-01

    The construction of the forward spectrometer for the 4π SPHERE setup to study multiple production of particles in nucleus-nucleus interactions is described. The measured parameters of the spectrometer detectors are presented. 7 refs.; 14 figs.; 1 tab

  15. Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

    Energy Technology Data Exchange (ETDEWEB)

    Khalvati, Farzad, E-mail: farzad.khalvati@uwaterloo.ca; Tizhoosh, Hamid R. [Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada); Salmanpour, Aryan; Rahnamayan, Shahryar [Department of Engineering and Applied Science, University of Ontario Institute of Technology, Oshawa, Ontario L1H 7K4 (Canada); Rodrigues, George [Department of Radiation Oncology, London Regional Cancer Program, London, Ontario N6C 2R6, Canada and Department of Epidemiology/Biostatistics, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2013-12-15

    Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

  16. Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

    International Nuclear Information System (INIS)

    Khalvati, Farzad; Tizhoosh, Hamid R.; Salmanpour, Aryan; Rahnamayan, Shahryar; Rodrigues, George

    2013-01-01

    Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability

  17. Effects of chemotherapeutics on organotypic corticostriatal slice cultures identified by a panel of fluorescent and immunohistochemical markers

    DEFF Research Database (Denmark)

    Nørregaard, Annette; Jensen, Stine Skov; Kolenda, Jesper

    2012-01-01

    no toxicity was observed. Corresponding immunostaining showed loss of MAP2 and increased expression of GFAP and p25α for cultures exposed to 1,000 nM VCR. Cultures exposed to high concentrations of ACNU and IM disintegrated, leaving no tissue for histology. In conclusion, corticostriatal slice cultures...... specific neuronal and glial degeneration induced by chemotherapeutics in organotypic rat corticostriatal slice cultures. The slice cultures were exposed to the alkylating agents temozolomide (TMZ) and nimustine (ACNU), the tyrosine kinase inhibitor imatinib mesylate (IM) and the microtubule...

  18. The Sliced Pineapple Grid Feature for Predicting Grasping Affordances

    DEFF Research Database (Denmark)

    Thomsen, Mikkel Tang; Kraft, Dirk; Krüger, Norbert

    2017-01-01

    The problem of grasping unknown objects utilising vision is addressed in this work by introducing a novel feature, the Sliced Pineapple Grid Feature (SPGF). The SPGF encode semi-local surfaces and allows for distinguishing structures such as “walls”,“edges” and “rims”. These structures are shown...

  19. A new instrumental set-up for polarized neutron scattering experiments

    International Nuclear Information System (INIS)

    Schmidt, Wolfgang; Ohl, Michael

    2005-01-01

    Neutron scattering with polarization analysis is a powerful tool to determine magnetic structures and excitations. A common setup is to mount the sample at the center of a Helmholtz-type coil which can provide a magnetic field of any direction at the sample position and also a guide field along the neutron flight paths around the sample. Recent experiments showed quite a high demand for measurements at low momentum transfers. For the corresponding low scattering angles air scattering gives rise to a very large background. For this reason we have extended the standard setup to a combination of a large vacuum tank surrounded by electrical coils. The vacuum tank eliminates the air scattering and we can use the polarization analysis down to the lowest accessible momentum transfers. The coils themselves also show some new features: In contrary to the classic (symmetric) coil distribution we use an asymmetric setup which gives the advantage of a larger scattering window. Due to a more sophisticated current distribution this modified coil arrangement needs not to be rotated for different scattering conditions. The whole set-up will soon be available at IN12, a cold neutrons three-axis spectrometer operated by FZ Juelich in collaboration with CEA Grenoble as a CRG-B instrument at the Institut Laue Langevin in Grenoble

  20. Characterization of a neutron imaging setup at the INES facility

    Energy Technology Data Exchange (ETDEWEB)

    Durisi, E.A., E-mail: elisabettaalessandra.durisi@unito.it [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Visca, L. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Albertin, F.; Brancaccio, R. [Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Corsi, J. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Dughera, G. [Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Ferrarese, W. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Giovagnoli, A.; Grassi, N. [Fondazione Centro per la Conservazione ed il Restauro dei Beni Culturali “La Venaria Reale”, Piazza della Repubblica, 10078 Venaria Reale, Torino (Italy); Grazzi, F. [Consiglio Nazionale delle Ricerche, Istituto dei Sistemi Complessi, Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze (Italy); Lo Giudice, A.; Mila, G. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); and others

    2013-10-21

    The Italian Neutron Experimental Station (INES) located at the ISIS pulsed neutron source (Didcot, United Kingdom) provides a thermal neutron beam mainly used for diffraction analysis. A neutron transmission imaging system was also developed for beam monitoring and for aligning the sample under investigation. Although the time-of-flight neutron diffraction is a consolidated technique, the neutron imaging setup is not yet completely characterized and optimized. In this paper the performance for neutron radiography and tomography at INES of two scintillator screens read out by two different commercial CCD cameras is compared in terms of linearity, signal-to-noise ratio, effective dynamic range and spatial resolution. In addition, the results of neutron radiographies and a tomography of metal alloy test structures are presented to better characterize the INES imaging capabilities of metal artifacts in the cultural heritage field. -- Highlights: A full characterization of the present INES imaging set-up was carried out. Two CCD cameras and two scintillators (ZnS/{sup 6}LiF) of different thicknesses were tested. Linearity, effective dynamic range and spatial resolution were determined. Radiographies of steep wedges were performed using the highest dynamic range setup. Tomography of a bronze cube was performed using the best spatial resolution setup.

  1. Characterization of a neutron imaging setup at the INES facility

    International Nuclear Information System (INIS)

    Durisi, E.A.; Visca, L.; Albertin, F.; Brancaccio, R.; Corsi, J.; Dughera, G.; Ferrarese, W.; Giovagnoli, A.; Grassi, N.; Grazzi, F.; Lo Giudice, A.; Mila, G.

    2013-01-01

    The Italian Neutron Experimental Station (INES) located at the ISIS pulsed neutron source (Didcot, United Kingdom) provides a thermal neutron beam mainly used for diffraction analysis. A neutron transmission imaging system was also developed for beam monitoring and for aligning the sample under investigation. Although the time-of-flight neutron diffraction is a consolidated technique, the neutron imaging setup is not yet completely characterized and optimized. In this paper the performance for neutron radiography and tomography at INES of two scintillator screens read out by two different commercial CCD cameras is compared in terms of linearity, signal-to-noise ratio, effective dynamic range and spatial resolution. In addition, the results of neutron radiographies and a tomography of metal alloy test structures are presented to better characterize the INES imaging capabilities of metal artifacts in the cultural heritage field. -- Highlights: A full characterization of the present INES imaging set-up was carried out. Two CCD cameras and two scintillators (ZnS/ 6 LiF) of different thicknesses were tested. Linearity, effective dynamic range and spatial resolution were determined. Radiographies of steep wedges were performed using the highest dynamic range setup. Tomography of a bronze cube was performed using the best spatial resolution setup

  2. Virtualization Security Combining Mandatory Access Control and Virtual Machine Introspection

    OpenAIRE

    Win, Thu Yein; Tianfield, Huaglory; Mair, Quentin

    2014-01-01

    Virtualization has become a target for attacks in cloud computing environments. Existing approaches to protecting the virtualization environment against the attacks are limited in protection scope and are with high overheads. This paper proposes a novel virtualization security solution which aims to provide comprehensive protection of the virtualization environment.

  3. Effect of dentin bonding agent diffusing through dentin slices on the reactive oxygen species production and apoptosis of pulpal cells

    Directory of Open Access Journals (Sweden)

    Bor-Shiunn Lee

    2015-04-01

    Conclusion: The three DBAs after diffusion through 0.2- or 0.5-mm dentin slice still exhibit cytotoxicity to dental pulp cells. However, the 0.5-mm dentin slice is found to be a better barrier than the 0.2-mm dentin slice to protect dental pulp cells from DBA-induced cytotoxicity.

  4. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    CERN Document Server

    Al-Jarallah, M I; Fazal-Ur-Rehman; Abu-Jarad, F A

    2002-01-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has bee...

  5. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I.; Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman; Abu-jarad, F

    2002-10-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has been found between the experimental results and the calculations.

  6. Lower limb immobilization device induced small setup errors in the radiotherapy.

    Science.gov (United States)

    Lu, Yuting; Ni, Xinye; Yu, Jingping; Ni, Xinchu; Sun, Zhiqiang; Wang, Jianlin; Sun, Suping; Wang, Jian

    2018-04-01

    The aim of this study was to design a lower limb immobilization device and investigate its clinical application in the radiotherapy of the lower limbs.Around 38 patients who underwent lower limb radiotherapy using the designed immobilization device were included in this study. The setup errors were calculated by comparison of the portal images and the simulator films or digital reconstructed radiographs (DRRs).From all 38 patients accomplished the radiotherapy using this device, 178 anteroposterior portal images and 178 lateral portal images were used for the analysis of the positional accuracy. Significant differences were observed in the setup error of the head-foot direction compared with the left-right direction (t = 3.404, P = .002) and the anterior-posterior directions (t = 3.188, P = .003). No statistical differences were identified in the setup error in the left-right direction and anterior-posterior direction (t = 0.497, P = .622).The use of the in-house designed lower limb immobilization device allowed for relatively small setup errors. Furthermore, it showed satisfactory accuracy and repeatability.

  7. Unbiased stereological estimation of d-dimensional volume in Rn from an isotropic random slice through a fixed point

    DEFF Research Database (Denmark)

    Jensen, Eva B. Vedel; Kiêu, K

    1994-01-01

    Unbiased stereological estimators of d-dimensional volume in R(n) are derived, based on information from an isotropic random r-slice through a specified point. The content of the slice can be subsampled by means of a spatial grid. The estimators depend only on spatial distances. As a fundamental ...... lemma, an explicit formula for the probability that an isotropic random r-slice in R(n) through 0 hits a fixed point in R(n) is given....

  8. The effect of slicing type on drying kinetics and quality of dried carrot

    Directory of Open Access Journals (Sweden)

    M Naghipour zadeh mahani

    2016-04-01

    Full Text Available Introduction: Carrot is one of the most common vegetables used for human nutrition because of its high vitamin and fiber contents. Drying improves the product shelf life without addition of any chemical preservative and reduces both the size of package and the transport cost. Drying also aidsto reduce postharvest losses of fruits and vegetables especially, which can be as high as 70%. Dried carrots are used in dehydrated soups and in the form of powder in pastries and sauces. The main aim of drying agricultural products is decrease the moisture content to a level which allows safe storage over an extended period. Many fruits and vegetables can be sliced before drying.because of different tissue of a fruit or vegetable, cutting them in different direction and shape created different tissue slices. Due to drying is the exiting process of the moisture from internal tissue so different tissue slices caused different drying kinetics. Therefore, the study on effect of cutting parameters on drying is necessary. Materials and Methods: Carrots (Daucus carota L. were purchased from the local market (Kerman, Iran and stored in a refrigerator at 5°C. The initial moisture contents of the Carrot samples were determined by the oven drying method. The sample was dried in an oven at 105±2°C about 24 hours. The carrots cut by 3 models blade at 3 directions. The samples were dried in an oven at 70°C. Moisture content of the carrot slices were determined by weighting of samples during drying. Volume changes because of sample shrinkage were measured by a water displacement method. Rehydration experiment was performed by immersing a weighted amount of dried samples into hot water 50 °C for 30 min. In this study the effect of some cutting parameters was considered on carrot drying and the quality of final drying product. The tests were performed as a completely random design. The effects of carrot thickness at two levels (3 and 6 mm, blade in 3 models (flat blade

  9. Liver slices in in vitro pharmacotoxicology with special reference to the use of human liver tissue

    NARCIS (Netherlands)

    Olinga, Peter; Meijer, D.K F; Slooff, M.JH; Groothuis, Geny

    In the early years of research in in vitro pharmacotoxicology liver slices have been used. After a decline in the application of slices in favour of the use of isolated hepatocytes and the isolated perfused liver preparation, the development of the Krumdieck slicer in the 1980s led to a 'comeback'

  10. Long-term potentiation protects rat hippocampal slices from the effects of acute hypoxia.

    Science.gov (United States)

    Youssef, F F; Addae, J I; McRae, A; Stone, T W

    2001-07-13

    We have previously shown that long-term potentiation (LTP) decreases the sensitivity of glutamate receptors in the rat hippocampal CA1 region to exogenously applied glutamate agonists. Since the pathophysiology of hypoxia/ischemia involves increased concentration of endogenous glutamate, we tested the hypothesis that LTP could reduce the effects of hypoxia in the hippocampal slice. The effects of LTP on hypoxia were measured by the changes in population spike potentials (PS) or field excitatory post-synaptic potentials (fepsps). Hypoxia was induced by perfusing the slice with (i) artificial CSF which had been pre-gassed with 95%N2/5% CO2; (ii) artificial CSF which had not been pre-gassed with 95% O2/5% CO2; or (iii) an oxygen-glucose deprived (OGD) medium which was similar to (ii) and in which the glucose had been replaced with sucrose. Exposure of a slice to a hypoxic medium for 1.5-3.0 min led to a decrease in the PS or fepsps; the potentials recovered to control levels within 3-5 min. Repeat exposure, 45 min later, of the same slice to the same hypoxic medium for the same duration as the first exposure caused a reduction in the potentials again; there were no significant differences between the degree of reduction caused by the first or second exposure for all three types of hypoxic media (P>0.05; paired t-test). In some of the slices, two episodes of LTP were induced 25 and 35 min after the first hypoxic exposure; this caused inhibition of reduction in potentials caused by the second hypoxic insult which was given at 45 min after the first; the differences in reduction in potentials were highly significant for all the hypoxic media used (Peffects of LTP were not prevented by cyclothiazide or inhibitors of NO synthetase compounds that have been shown to be effective in blocking the effects of LTP on the actions of exogenously applied AMPA and NMDA, respectively. The neuroprotective effects of LTP were similar to those of propentofylline, a known neuroprotective

  11. The use of adaptive radiation therapy to reduce setup error: a prospective clinical study

    International Nuclear Information System (INIS)

    Yan Di; Wong, John; Vicini, Frank; Robertson, John; Horwitz, Eric; Brabbins, Donald; Cook, Carla; Gustafson, Gary; Stromberg, Jannifer; Martinez, Alvaro

    1996-01-01

    Purpose: Adaptive Radiation Therapy (ART) is a closed-loop feedback process where each patients treatment is adaptively optimized according to the individual variation information measured during the course of treatment. The process aims to maximize the benefits of treatment for the individual patient. A prospective study is currently being conducted to test the feasibility and effectiveness of ART for clinical use. The present study is limited to compensating the effects of systematic setup error. Methods and Materials: The study includes 20 patients treated on a linear accelerator equipped with a computer controlled multileaf collimator (MLC) and a electronic portal imaging device (EPID). Alpha cradles are used to immobilize those patients treated for disease in the thoracic and abdominal regions, and thermal plastic masks for the head and neck. Portal images are acquired daily. Setup error of each treatment field is quantified off-line every day. As determined from an earlier retrospective study of different clinical sites, the measured setup variation from the first 4 to 9 days, are used to estimate systematic setup error and the standard deviation of random setup error for each field. Setup adjustment is made if estimated systematic setup error of the treatment field was larger than or equal to 2 mm. Instead of the conventional approach of repositioning the patient, setup correction is implemented by reshaping MLC to compensate for the estimated systematic error. The entire process from analysis of portal images to the implementation of the modified MLC field is performed via computer network. Systematic and random setup errors of the treatment after adjustment are compared with those prior to adjustment. Finally, the frequency distributions of block overlap cumulated throughout the treatment course are evaluated. Results: Sixty-seven percent of all treatment fields were reshaped to compensate for the estimated systematic errors. At the time of this writing

  12. Shoulder kinematics and spatial pattern of trapezius electromyographic activity in real and virtual environments.

    Directory of Open Access Journals (Sweden)

    Afshin Samani

    Full Text Available The design of an industrial workstation tends to include ergonomic assessment steps based on a digital mock-up and a virtual reality setup. Lack of interaction and system fidelity is often reported as a main issue in such virtual reality applications. This limitation is a crucial issue as thorough ergonomic analysis is required for an investigation of the biomechanics. In the current study, we investigated the biomechanical responses of the shoulder joint in a simulated assembly task for comparison with the biomechanical responses in virtual environments. Sixteen male healthy novice subjects performed the task on three different platforms: real (RE, virtual (VE, and virtual environment with force feedback (VEF with low and high precision demands. The subjects repeated the task 12 times (i.e., 12 cycles. High density electromyography from the upper trapezius and rotation angles of the shoulder joint were recorded and split into the cycles. The angular trajectories and velocity profiles of the shoulder joint angles over a cycle were computed in 3D. The inter-subject similarity in terms of normalized mutual information on kinematics and electromyography was investigated. Compared with RE the task in VE and VEF was characterized by lower kinematic maxima. The inter-subject similarity in RE compared with intra-subject similarity across the platforms was lower in terms of movement trajectories and greater in terms of trapezius muscle activation. The precision demand resulted in lower inter- and intra-subject similarity across platforms. The proposed approach identifies biomechanical differences in the shoulder joint in both VE and VEF compared with the RE platform, but these differences are less marked in VE mostly due to technical limitations of co-localizing the force feedback system in the VEF platform.

  13. Quick setup of test unit for accelerator control system

    International Nuclear Information System (INIS)

    Fu, W.; D'Ottavio, T.; Gassner, D.; Nemesure, S.; Morris, J.

    2011-01-01

    Testing a single hardware unit of an accelerator control system often requires the setup of a program with graphical user interface. Developing a dedicated application for a specific hardware unit test could be time consuming and the application may become obsolete after the unit tests. This paper documents a methodology for quick design and setup of an interface focused on performing unit tests of accelerator equipment with minimum programming work. The method has three components. The first is a generic accelerator device object (ADO) manager which can be used to setup, store, and log testing controls parameters for any unit testing system. The second involves the design of a TAPE (Tool for Automated Procedure Execution) sequence file that specifies and implements all te testing and control logic. The sting third is the design of a PET (parameter editing tool) page that provides the unit tester with all the necessary control parameters required for testing. This approach has been used for testing the horizontal plane of the Stochastic Cooling Motion Control System at RHIC.

  14. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  15. The slice balance approach (SBA): a characteristic-based, multiple balance SN approach on unstructured polyhedral meshes

    International Nuclear Information System (INIS)

    Grove, R.E.

    2005-01-01

    The Slice Balance Approach (SBA) is an approach for solving geometrically-complex, neutral-particle transport problems within a multi-group discrete ordinates (S N ) framework. The salient feature is an angle-dependent spatial decomposition. We approximate general surfaces with arbitrary polygonal faces and mesh the geometry with arbitrarily-shaped polyhedral cells. A cell-local spatial decomposition divides cells into angle-dependent slices for each S N direction. This subdivision follows from a characteristic-based view of the transport problem. Most balance-based characteristic methods use it implicitly; we use it explicitly and exploit its properties. Our mathematical approach is a multiple balance approach using exact spatial moments balance equations on cells and slices along with auxiliary relations on slices. We call this the slice balance approach; it is a characteristic-based multiple balance approach. The SBA is intentionally general and can extend differencing schemes to arbitrary 2-D and 3-D meshes. This work contributes to development of general-geometry deterministic transport capability to complement Monte Carlo capability for large, geometrically-complex transport problems. The purpose of this paper is to describe the SBA. We describe the spatial decomposition and mathematical framework and highlight a few interesting properties. We sketch the derivation of two solution schemes, a step characteristic scheme and a diamond-difference-like scheme, to illustrate the approach and we present interesting results for a 2-D problem. (author)

  16. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Pugliese, Francesca; Krestin, Gabriel P.; Mollet, Nico R.A.; DeFeyter, Pim J.; Runza, Giuseppe; Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo; Malagutti, Patrizia; Cademartiri, Filippo

    2006-01-01

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as ≥ 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  17. Comparison of sliced lungs with whole lung sets for a torso phantom measured with Ge detectors using Monte Carlo simulations (MCNP).

    Science.gov (United States)

    Kramer, Gary H; Guerriere, Steven

    2003-02-01

    Lung counters are generally used to measure low energy photons (<100 keV). They are usually calibrated with lung sets that are manufactured from a lung tissue substitute material that contains homogeneously distributed activity; however, it is difficult to verify either the activity in the phantom or the homogeneity of the activity distribution without destructive testing. Lung sets can have activities that are as much as 25% different from the expected value. An alternative method to using whole lungs to calibrate a lung counter is to use a sliced lung with planar inserts. Experimental work has already indicated that this alternative method of calibration can be a satisfactory substitute. This work has extended the experimental study by the use of Monte Carlo simulation to validate that sliced and whole lungs are equivalent. It also has determined the optimum slice thicknesses that separate the planar sources in the sliced lung. Slice thicknesses have been investigated in the range of 0.5 cm to 9.0 cm and at photon energies from 17 keV to 1,000 keV. Results have shown that there is little difference between sliced and whole lungs at low energies providing that the slice thickness is 2.0 cm or less. As the photon energy rises the slice thickness can increase substantially with no degradation on equivalence.

  18. Tele-surgery: a new virtual tool for medical education.

    Science.gov (United States)

    Russomano, Thais; Cardoso, Ricardo B; Fernandes, Jefferson; Cardoso, Paulizan G; Alves, Jarcedy M; Pianta, Christina D; Souza, Hamilton P; Lopes, Maria Helena I

    2009-01-01

    The rapid evolution of telecommunication technology has enabled advances to be made in low cost video-conferencing through the improvement of high speed computer communication networks and the enhancement of Internet security protocols. As a result of this progress, eHealth education programs are becoming a reality in universities, providing the opportunity for students to have greater interaction at live surgery classes by means of virtual participation. Undergraduate students can be introduced to new concepts of medical care, remote second opinion and to telecommunication systems, whilst virtually experiencing surgical procedures and lectures. The better access this provides to the operating theater environment, the patient and the surgeon can improve the learning process for students. An analogical system was used for this experimental pilot project due to the benefits of it being low cost with a comparatively easy setup. The tele-surgery lectures were also transmitted to other universities by means of a Pentium 4 computer using open source software and connected to a portable image acquisition device located in the São Lucas University Hospital. Telemedicine technology has proven to be an important instrument for the improvement of medical education and health care. This study allowed health professionals, professors and students to have greater interaction during surgical procedures, thus enabling a greater opportunity for knowledge exchange.

  19. High-resolution continuous-flow analysis setup for water isotopic measurement from ice cores using laser spectroscopy

    Science.gov (United States)

    Emanuelsson, B. D.; Baisden, W. T.; Bertler, N. A. N.; Keller, E. D.; Gkinis, V.

    2015-07-01

    Here we present an experimental setup for water stable isotope (δ18O and δD) continuous-flow measurements and provide metrics defining the performance of the setup during a major ice core measurement campaign (Roosevelt Island Climate Evolution; RICE). We also use the metrics to compare alternate systems. Our setup is the first continuous-flow laser spectroscopy system that is using off-axis integrated cavity output spectroscopy (OA-ICOS; analyzer manufactured by Los Gatos Research, LGR) in combination with an evaporation unit to continuously analyze water samples from an ice core. A Water Vapor Isotope Standard Source (WVISS) calibration unit, manufactured by LGR, was modified to (1) enable measurements on several water standards, (2) increase the temporal resolution by reducing the response time and (3) reduce the influence from memory effects. While this setup was designed for the continuous-flow analysis (CFA) of ice cores, it can also continuously analyze other liquid or vapor sources. The custom setups provide a shorter response time (~ 54 and 18 s for 2013 and 2014 setup, respectively) compared to the original WVISS unit (~ 62 s), which is an improvement in measurement resolution. Another improvement compared to the original WVISS is that the custom setups have a reduced memory effect. Stability tests comparing the custom and WVISS setups were performed and Allan deviations (σAllan) were calculated to determine precision at different averaging times. For the custom 2013 setup the precision after integration times of 103 s is 0.060 and 0.070 ‰ for δ18O and δD, respectively. The corresponding σAllan values for the custom 2014 setup are 0.030, 0.060 and 0.043 ‰ for δ18O, δD and δ17O, respectively. For the WVISS setup the precision is 0.035, 0.070 and 0.042 ‰ after 103 s for δ18O, δD and δ17O, respectively. Both the custom setups and WVISS setup are influenced by instrumental drift with δ18O being more drift sensitive than δD. The

  20. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

    International Nuclear Information System (INIS)

    Salluzzi, M; Frayne, R; Smith, M R

    2006-01-01

    Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies