WorldWideScience

Sample records for videorecordings 16mm film

  1. Catalogue of Videorecordings and Films, Kindergarten to Grade 6, 1993.

    Science.gov (United States)

    Manitoba Dept. of Education, Winnipeg. Instructional Resources Branch.

    This catalogue lists and indexes 2,233 videorecordings, 16mm film, and videodisc titles held by the Library, Manitoba Education and Training for borrowing; some are also available for dubbing. The catalog indexes materials intended for children in kindergarten through grade 6, and is divided into three parts: an annotated title and series index, a…

  2. Film Editing Handbook; Technique of 16mm Film Cutting.

    Science.gov (United States)

    Churchill, Hugh B.

    Designed to help the film student with the complexities of 16mm film cutting, this handbook catalogs the mechanical procedures of both picture and sound cutting and supplies step-by-step explanations of these procedures. Because the handbook was organized so that it could be used while working at the cutting bench, common cutting problems and…

  3. Films--Too Good for Words. A Directory of Nonnarrated 16mm Films.

    Science.gov (United States)

    Parlato, Salvatore J., Jr.

    A nonnarrated film is one that communicates pictorially on the strength of its visual unity, continuity, and coherence without relying on narration or dialogue. This directory lists 1,000 such 16mm films, mostly curriculum-oriented educational films, in three main parts. The first part describes films under subject headings such as the arts, other…

  4. Feasibility of converting hi-speed processor for processing Kodak film types 7381/7271 (16mm) and 5381/5271 (35mm) using Kodak ECP chemistry

    Science.gov (United States)

    Weinstein, M. S.

    1974-01-01

    Testing conducted to determine the feasibility of converting the 16/35/70 hi-speed processor to process Kodak film types 7381/7271 (16mm) and 5381/5271 (35mm) color negative films using Kodak ECP chemistry is described.

  5. Magnetometer Data recovered from 35mm film

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The L57 CDMP recovery project takes magnetometer data on 35mm film stored at the archive's climate controlled warehouse and digitizes them.

  6. Ethical issues in videorecording patients lacking capacity to consent

    Directory of Open Access Journals (Sweden)

    Carlo Petrini

    2011-01-01

    Full Text Available Videorecording of patients requires the utmost respect for the privacy and confidentiality of the patients. Consent should be requested from patients for all videorecording. When a mental disability or mental or physical illness prevents patients from giving their permission, agreement to recording from a legal representative or from a close relative or carer are necessary. Three documents on this subject issued in the United Kingdom, the United State of America and Italy are briefly summarized and discussed. The problem of consent for videorecording is addressed particularly in reference to persons incapable of making decisions on their own, such as persons in vegetative state. The general ethical framework is outlined and a few practical proposals are given.

  7. Live lecture versus video-recorded lecture: are students voting with their feet?

    Science.gov (United States)

    Cardall, Scott; Krupat, Edward; Ulrich, Michael

    2008-12-01

    In light of educators' concerns that lecture attendance in medical school has declined, the authors sought to assess students' perceptions, evaluations, and motivations concerning live lectures compared with accelerated, video-recorded lectures viewed online. The authors performed a cross-sectional survey study of all first- and second-year students at Harvard Medical School. Respondents answered questions regarding their lecture attendance; use of class and personal time; use of accelerated, video-recorded lectures; and reasons for viewing video-recorded and live lectures. Other questions asked students to compare how well live and video-recorded lectures satisfied learning goals. Of the 353 students who received questionnaires, 204 (58%) returned responses. Collectively, students indicated watching 57.2% of lectures live, 29.4% recorded, and 3.8% using both methods. All students have watched recorded lectures, and most (88.5%) have used video-accelerating technologies. When using accelerated, video-recorded lecture as opposed to attending lecture, students felt they were more likely to increase their speed of knowledge acquisition (79.3% of students), look up additional information (67.7%), stay focused (64.8%), and learn more (63.7%). Live attendance remains the predominant method for viewing lectures. However, students find accelerated, video-recorded lectures equally or more valuable. Although educators may be uncomfortable with the fundamental change in the learning process represented by video-recorded lecture use, students' responses indicate that their decisions to attend lectures or view recorded lectures are motivated primarily by a desire to satisfy their professional goals. A challenge remains for educators to incorporate technologies students find useful while creating an interactive learning culture.

  8. TEACHER-PRODUCED INSTRUCTIONAL FILMS IN CHEMISTRY, 8MM AND SUPER 8.

    Science.gov (United States)

    O'CONNOR, ROD; SLABAUGH, WENDELL

    TECHNIQUES FOR PRODUCING 8MM INSTRUCTIONAL FILMS IN CHEMISTRY ARE PRESENTED. IN PART I A PHILOSOPHY OF TEACHER-PRODUCED FILMS IS DEVELOPED, EMPHASIZING THE VALUE OF THE LOCAL SETTING, AND CUSTOM-MADE CONTENTS. APPLICATIONS SUGGESTED ARE (1) TECHNIQUE INSTRUCTION, (2) FILMED EXPERIMENTS, (3) INSTRUMENT FAMILIARIZATION, (4) LECTURE AIDS, AND (5)…

  9. Diagnostic capability of 100-mm roll film digitizer system

    International Nuclear Information System (INIS)

    Kono, M.; Yamasaki, K.; Ikeda, M.

    1988-01-01

    The authors recently developed a roll film digitizer system. The sampling pitch is 100 μm. a scientific image study (Barger phantom, Hawlet chart, and modulation transfer function), receiver operating characteristic (ROC) study, and clinical evaluation were performed. For the ROC study, a chest phantom with simulated nodule and hairline was used. Differences in accuracy between readings of cathode ray tube (CRT) images and roll film images were not statistically significant for hairline and coin lesions, P<.05). As a clinical evaluation, eight radiologists evaluated predetermined radiologic findings on a five-point rating scale compared with original roll film images. Scores for CRT images were equal to those for the original roll film images. In conclusion, CRT images (1,000 x 1,000) were found to be sufficient for diagnostic accuracy of chest images compared with roll film images (100 x 100 mm)

  10. Comparison of image quality and radiation exposure from digital and 105-mm film images in pediatric fluoroscopy

    International Nuclear Information System (INIS)

    Drake, D.G.; Day, D.L.; Alford, B.A.; Geise, R.; Thompson, W.M.

    1987-01-01

    This study was designed to compare image quality of digitally acquired films compared with conventional 105-mm films in pediatric gastrointestinal and genitourinary fluoroscopic studies. Films were acquired digitally in 1,024 x 1,024 matrix, 512 x 512 matrix, and 105-mm film. Based on the observers' median scoring, the 1,024 x 1,024 reduced to 512 x 512 matrix provided similar overall image quality to the 105-mm films. The digital images produced a patient radiation exposure of 25% to 30% that of the 105-mm images on their equipment. The authors conclude that digital images provide similar image quality to 105-mm images with a significant reduction in patient radiation exposure

  11. Discovery in Film, Book Two.

    Science.gov (United States)

    Gordon, Malcolm W.

    Approximately 80 16 millimeter (16mm) short films are reviewed in this introduction and guide which attempts to be comprehensive in touching the major areas and styles of 16mm films now being produced. An attempt is made to describe as carefully as possible the style and content of each film and suggest ways in which the films might be used. Films…

  12. 16 CFR 501.1 - Camera film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Camera film. 501.1 Section 501.1 Commercial... 500 § 501.1 Camera film. Camera film packaged and labeled for retail sale is exempt from the net... should be expressed, provided: (a) The net quantity of contents on packages of movie film and bulk still...

  13. Multicolor photoluminescence in ITQ-16 zeolite film

    KAUST Repository

    Chen, Yanli

    2016-09-07

    Exploring the native defects of zeolites is highly important for understanding the properties of zeolites, such as catalysis and optics. Here, ITQ-16 films were prepared via the secondary growth method in the presence of Ge atoms. Various intrinsic defects of ITQ-16 films were fully studied through photoluminescence and FTIR characterizations. It was found that both the as-synthesized and calcined ITQ-16 films displayed multicolor photoluminescence including ultraviolet, blue, green and red emissions by exciting upon appropriate wavelengths. The results indicate that Si―OH and non-bridging oxygen hole centers(NBOHCs) are responsible for the origin of green and red emissions at 540―800 nm, while according to a variety of emission bands of calcined ITQ-16 film, blue emission bands at around 446 and 462 nm are attributed to peroxy free radicals(≡SiO2), ultraviolet emissions ranging from 250 nm to 450 nm are suggested originating from a singlet-to-triplet transition of two-fold-coordinated Si and Ge, respectively. © 2016, Jilin University, The Editorial Department of Chemical Research in Chinese Universities and Springer-Verlag GmbH.

  14. FAA Film Catalog.

    Science.gov (United States)

    Federal Aviation Administration (DOT), Washington, DC.

    Some 75 films from the U.S. Department of Transportation's Federal Aviation Administration are listed in this catalog. Topics dealt with include aerodynamics, airports, aviation history and careers, flying clubs, navigation and weather. Most of the films are 16mm sound and color productions. Filmstrips requiring a 35mm projector and phonograph or…

  15. A new methodology for the preparation of 1 mm film for TEM analysis of austenitic steels irradiated with neutrons

    International Nuclear Information System (INIS)

    Bublikova, P.; Rosnecky, V.; Srba, V.; Michalicka, J.

    2014-01-01

    The methodology describes the process of manufacturing 1 mm steel sheets by the method of handling the tensile samples, cutting the samples after the tensile test in the tapered part of the neck by manipulators in a shielded environment of bittersweet chamber, grinding of active samples in glove boxes, cutting out sheets with 1 mm diameter with a special punch and the final electrolytic polishing of 1 mm films for TEM analysis of radiation defects in the transparent area of the film. (authors)

  16. A Piezoelectric Micromotor with a Stator of φ=1.6 mm and l=4 mm Using Bulk PZT

    Science.gov (United States)

    Cagatay, Serra; Koc, Burhanettin; Moses, Paul; Uchino, Kenji

    2004-04-01

    The smallest discrete piezoelectric ultrasonic motor using bulk ceramics was developed. We are proposing basically a two-part motor: stator and rotor. The stator of the present motor consists of a hollow metal brass tube with outer diameter of 1.6 mm, inner diameter of 0.8 mm and length of only 4 mm with 2 PZT plates bonded onto it. Owing to the asymmetrical stator surface, two degenerated orthogonal bending modes were slightly split, resulting in a wobbling motion. Thus, the motor can be driven by a single driving source. The rotor is a spring, which is basically different from previous designs, pressed at both ends to the stator by a pair of ferrules. Consequently, the length of the whole motor assembly was reduced significantly; a final motor length of only 5 mm was obtained. The working frequency under zero load was approximately 227-233 kHz. Although the size is small, relatively high power was obtained under an optimized load condition: torque of 0.06 mNm, maximum power of 3.2 mW with a speed of 118 rad/s, and maximum efficiency of 11% under 48 Vrms at 221 kHz.

  17. Self-Reflection of Video-Recorded High-Fidelity Simulations and Development of Clinical Judgment.

    Science.gov (United States)

    Bussard, Michelle E

    2016-09-01

    Nurse educators are increasingly using high-fidelity simulators to improve prelicensure nursing students' ability to develop clinical judgment. Traditionally, oral debriefing sessions have immediately followed the simulation scenarios as a method for students to connect theory to practice and therefore develop clinical judgment. Recently, video recording of the simulation scenarios is being incorporated. This qualitative, interpretive description study was conducted to identify whether self-reflection on video-recorded high-fidelity simulation (HFS) scenarios helped prelicensure nursing students to develop clinical judgment. Tanner's clinical judgment model was the framework for this study. Four themes emerged from this study: Confidence, Communication, Decision Making, and Change in Clinical Practice. This study indicated that self-reflection of video-recorded HFS scenarios is beneficial for prelicensure nursing students to develop clinical judgment. [J Nurs Educ. 2016;55(9):522-527.]. Copyright 2016, SLACK Incorporated.

  18. Influence of oil on flow condensation heat transfer of R410A inside 4.18 mm and 1.6 mm inner diameter horizontal smooth tubes

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiangchao; Ding, Guoliang; Hu, Haitao; Zhu, Yu.; Peng, Hao [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Gao, Yifeng [International Copper Association Shanghai Office, Shanghai 200020 (China); Deng, Bin [Institute of Heat Transfer Technology, Golden Dragon Precise Copper Tube Group Inc., Shanghai 200135 (China)

    2010-01-15

    The influence of oil on condensation heat transfer of R410A inside 4.18 mm and 1.6 mm inner diameter horizontal smooth tubes is investigated experimentally. The experimental condensing temperature is 40 C, and nominal oil concentration range is from 0% to 5%. The test results indicate that the presence of oil deteriorates the heat transfer, and the deterioration effect becomes obvious with the increase of oil concentration. At oil concentration of 5%, the heat transfer coefficient decreases by maximum 24.9% and 28.5% for 4.18 mm and 1.6 mm tubes, respectively. A new correlation for heat transfer coefficients of R410A-oil mixture flow condensation inside smooth tubes is proposed, which agrees with all the experimental data within a deviation of -30% {proportional_to} +20%. (author)

  19. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with 125I seeds (model I25.S16)

    International Nuclear Information System (INIS)

    Acar, Hilal; Chiu-Tsao, Sou-Tung; Özbay, İsmail; Kemikler, Gönül; Tuncer, Samuray

    2013-01-01

    Purpose: (1) To measure absolute dose distributions in eye phantom for COMS eye plaques with 125 I seeds (model I25.S16) using radiochromic EBT film dosimetry. (2) To determine the dose correction function for calculations involving the TG-43 formalism to account for the presence of the COMS eye plaque using Monte Carlo (MC) method specific to this seed model. (3) To test the heterogeneous dose calculation accuracy of the new version of Plaque Simulator (v5.3.9) against the EBT film data for this seed model. Methods: Using EBT film, absolute doses were measured for 125 I seeds (model I25.S16) in COMS eye plaques (1) along the plaque's central axis for (a) uniformly loaded plaques (14–20 mm in diameter) and (b) a 20 mm plaque with single seed, and (2) in off-axis direction at depths of 5 and 12 mm for all four plaque sizes. The EBT film calibration was performed at 125 I photon energy. MC calculations using MCNP5 code for a single seed at the center of a 20 mm plaque in homogeneous water and polystyrene medium were performed. The heterogeneity dose correction function was determined from the MC calculations. These function values at various depths were entered into PS software (v5.3.9) to calculate the heterogeneous dose distributions for the uniformly loaded plaques (of all four sizes). The dose distributions with homogeneous water assumptions were also calculated using PS for comparison. The EBT film measured absolute dose rate values (film) were compared with those calculated using PS with homogeneous assumption (PS Homo) and heterogeneity correction (PS Hetero). The values of dose ratio (film/PS Homo) and (film/PS Hetero) were obtained. Results: The central axis depth dose rate values for a single seed in 20 mm plaque measured using EBT film and calculated with MCNP5 code (both in ploystyrene phantom) were compared, and agreement within 9% was found. The dose ratio (film/PS Homo) values were substantially lower than unity (mostly between 0.8 and 0.9) for all

  20. Off-the-Air Educational Videorecording and Fair Use: Achieving a Delicate Balance.

    Science.gov (United States)

    Ramey, Ancil G.

    1984-01-01

    At each stage in the history of copyright law, technological innovation has been a central problem to policy makers. Because videorecording in an instructional context is for noncommerical, educational purposes, issues involving the doctrine of fair use and the public's interest in the free dissemination of information are raised. (MLW)

  1. Differential effects of film on preschool children's behaviour dependent on editing pace.

    Science.gov (United States)

    Kostyrka-Allchorne, Katarzyna; Cooper, Nicholas R; Gossmann, Anna Maria; Barber, Katy J; Simpson, Andrew

    2017-05-01

    Evidence on how the pace of television and film editing affects children's behaviour and attention is inconclusive. We examined whether a fast-paced film affected how preschool-aged children interacted with toys. The study comprised 70 children (36 girls) aged two to four-and-a-half years who attended preschools in Essex, United Kingdom. The children were paired up and tested with either a fast- or a slow-paced film of a narrator reading a children's story. The fast-paced version had 102 camera cuts and 16 still images, and the slow-paced version had 22 camera cuts and four still images. Each dyad took part in two video-recorded free-play sessions, before and after they watched one of the specially edited four-minute films. The number of toys the children played with before and after the film sessions was recorded. Before they watched the films, the children's behaviour did not differ between the groups. However, after watching the film, the children in the fast-paced group shifted their attention between toys more frequently than the children who watched the slow-paced film. Even a brief exposure to differently paced films had an immediate effect on how the children interacted with their toys. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. Abnormal eating behavior in video-recorded meals in anorexia nervosa.

    Science.gov (United States)

    Gianini, Loren; Liu, Ying; Wang, Yuanjia; Attia, Evelyn; Walsh, B Timothy; Steinglass, Joanna

    2015-12-01

    Eating behavior during meals in anorexia nervosa (AN) has long been noted to be abnormal, but little research has been done carefully characterizing these behaviors. These eating behaviors have been considered pathological, but are not well understood. The current study sought to quantify ingestive and non-ingestive behaviors during a laboratory lunch meal, compare them to the behaviors of healthy controls (HC), and examine their relationships with caloric intake and anxiety during the meal. A standardized lunch meal was video-recorded for 26 individuals with AN and 10 HC. Duration, frequency, and latency of 16 mealtime behaviors were coded using computer software. Caloric intake, dietary energy density (DEDS), and anxiety were also measured. Nine mealtime behaviors were identified that distinguished AN from HC: staring at food, tearing food, nibbling/picking, dissecting food, napkin use, inappropriate utensil use, hand fidgeting, eating latency, and nibbling/picking latency. Among AN, a subset of these behaviors was related to caloric intake and anxiety. These data demonstrate that the mealtime behaviors of patients with AN and HC differ significantly, and some of these behaviors may be associated with food intake and anxiety. These mealtime behaviors may be important treatment targets to improve eating behavior in individuals with AN. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Multicolor photoluminescence in ITQ-16 zeolite film

    KAUST Repository

    Chen, Yanli; Dong, Xinglong; Zhang, Zhenyu; Feng, Lai

    2016-01-01

    Exploring the native defects of zeolites is highly important for understanding the properties of zeolites, such as catalysis and optics. Here, ITQ-16 films were prepared via the secondary growth method in the presence of Ge atoms. Various intrinsic

  4. Epitaxial Fe16N2 thin film on nonmagnetic seed layer

    Science.gov (United States)

    Hang, Xudong; Zhang, Xiaowei; Ma, Bin; Lauter, Valeria; Wang, Jian-Ping

    2018-05-01

    Metastable α″ -Fe16N2 has attracted much interest as a candidate for rare-earth-free hard magnetic materials. We demonstrate that Fe16N2 thin films were grown epitaxially on Cr seed layers with MgO (001) substrates by facing-target sputtering. Good crystallinity with the epitaxial relation MgO (001 )[110 ] ∥ Cr (001 )[100 ] ∥ Fe16N2 (001 )[100 ] was obtained. The chemical order parameter, which quantifies the degree of N ordering in the Fe16N2 (the N-disordered phase is α' -Fe8N martensite), reaches 0.75 for Cr-seeded samples. Cr has a perfect lattice constant match with Fe16N2, and no noticeable strain can be assigned to Fe16N2. The intrinsic saturation magnetization of this non-strained Fe16N2 thin film at room temperature is determined to be 2.31 T by polarized neutron reflectometry and confirmed with vibrating sample magnetometry. Our work provides a platform to directly study the magnetic properties of high purity Fe16N2 films with a high order parameter.

  5. A List of U.S. Government Medical and Dental 8mm Films for Sale by the National Audiovisual Center.

    Science.gov (United States)

    National Archives and Records Service (GSA), Washington, DC. National Audiovisual Center.

    Over 200 8mm films for the use of doctors, dentists, and others in related fields are listed. Dental films are categorized into the following topics: anatomy -- head and neck; complete dentures; diagnosis; endodontics; fixed partial dentures; occlusion; operative dentistry; oral hygiene; patient education; periodontics; radiology; removable…

  6. 16 CFR 1611.35 - Testing certain classes of fabric and film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Testing certain classes of fabric and film... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.35 Testing certain classes of fabric and film. (a) Fabric not customarily washed or dry cleaned. (1) Except as...

  7. 16 CFR 1611.33 - Test procedures for textile fabrics and film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test procedures for textile fabrics and film... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.33 Test procedures for textile fabrics and film. (a)(1) All textile fabrics (except those with a nitro-cellulose...

  8. 16 CFR 1610.33 - Test procedures for textile fabrics and film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test procedures for textile fabrics and film... for textile fabrics and film. (a)(1) All textile fabrics (except those with a nitro-cellulose fiber... under the procedures outlined in part 1611, Standard for the Flammability of Vinyl Plastic Film, and if...

  9. The medical film 1897-1997: Part I. The first half-century.

    Science.gov (United States)

    Essex-Lopresti, M

    1998-03-01

    Medicine has frequently been in the forefront of applying new illustrative media to its needs, and cinematographic film is a good example. Within a year of the introduction of moving pictures, cine-film was used for medical research and to a lesser extent for teaching. The profession took advantage of the spread of cinemas by making health education films, and during the first half century of cinematography surgeons were keen to have their operations filmed. Medical educators were slow to include film in their teaching programmes and several organizations were formed to encourage their use. After the Second World War, medical films for undergraduate and postgraduate education became accepted until, as the medical film reached its centenary, cine-film declined in favour of video-recordings.

  10. Consumer Education Resources Catalog. 16mm Films, Multi Media Kits, Video Cassettes, Simulations & Games, Printed Material.

    Science.gov (United States)

    Jones, Sandra; Bannister, Rosella

    This catalog lists teaching-learning resources available for preview at the Michigan Consumer Education Center. A subject index to multi-media identifies titles of films, video casettes, multi-media kits, and games under seven specific subjects. These are (1) Factors Affecting Consumer Behavior, (2) Money Management and Credit, (3) Buying and…

  11. Selected Films for Young Adults, 1984.

    Science.gov (United States)

    Top of the News, 1984

    1984-01-01

    This 22-item filmography of 16mm films recommended for use in programs planned for young adults was compiled by the Selected Films for Young Adults Committee, Young Adult Services Division, American Library Association. Producers, directors, distributors, length, price, and brief annotations are provided. Addresses for 12 distributors are…

  12. The distinguishing motor features of cataplexy: a study from video-recorded attacks.

    Science.gov (United States)

    Pizza, Fabio; Antelmi, Elena; Vandi, Stefano; Meletti, Stefano; Erro, Roberto; Baumann, Christian R; Bhatia, Kailash P; Dauvilliers, Yves; Edwards, Mark J; Iranzo, Alex; Overeem, Sebastiaan; Tinazzi, Michele; Liguori, Rocco; Plazzi, Giuseppe

    2018-05-01

    To describe the motor pattern of cataplexy and to determine its phenomenological differences from pseudocataplexy in the differential diagnosis of episodic falls. We selected 30 video-recorded cataplexy and 21 pseudocataplexy attacks in 17 and 10 patients evaluated for suspected narcolepsy and with final diagnosis of narcolepsy type 1 and conversion disorder, respectively, together with self-reported attacks features, and asked expert neurologists to blindly evaluate the motor features of the attacks. Video documented and self-reported attack features of cataplexy and pseudocataplexy were contrasted. Video-recorded cataplexy can be positively differentiated from pseudocataplexy by the occurrence of facial hypotonia (ptosis, mouth opening, tongue protrusion) intermingled by jerks and grimaces abruptly interrupting laughter behavior (i.e. smile, facial expression) and postural control (head drops, trunk fall) under clear emotional trigger. Facial involvement is present in both partial and generalized cataplexy. Conversely, generalized pseudocataplexy is associated with persistence of deep tendon reflexes during the attack. Self-reported features confirmed the important role of positive emotions (laughter, telling a joke) in triggering the attacks, as well as the more frequent occurrence of partial body involvement in cataplexy compared with pseudocataplexy. Cataplexy is characterized by abrupt facial involvement during laughter behavior. Video recording of suspected cataplexy attacks allows the identification of positive clinical signs useful for diagnosis and, possibly in the future, for severity assessment.

  13. Hafnium Films and Magnetic Shielding for TIME, A mm-Wavelength Spectrometer Array

    Science.gov (United States)

    Hunacek, J.; Bock, J.; Bradford, C. M.; Butler, V.; Chang, T.-C.; Cheng, Y.-T.; Cooray, A.; Crites, A.; Frez, C.; Hailey-Dunsheath, S.; Hoscheit, B.; Kim, D. W.; Li, C.-T.; Marrone, D.; Moncelsi, L.; Shirokoff, E.; Steinbach, B.; Sun, G.; Trumper, I.; Turner, A.; Uzgil, B.; Weber, A.; Zemcov, M.

    2018-04-01

    TIME is a mm-wavelength grating spectrometer array that will map fluctuations of the 157.7-μm emission line of singly ionized carbon ([CII]) during the epoch of reionization (redshift z ˜ 5-9). Sixty transition-edge sensor (TES) bolometers populate the output arc of each of the 32 spectrometers, for a total of 1920 detectors. Each bolometer consists of gold absorber on a ˜ 3 × 3 mm silicon nitride micro-mesh suspended near the corners by 1 × 1 × 500 μm silicon nitride legs targeting a photon-noise-dominated NEP ˜ 1 × 10^{-17} W/√{Hz} . Hafnium films are explored as a lower-T_c alternative to Ti (500 mK) for TIME TESs, allowing thicker support legs for improved yield. Hf T_c is shown to vary between 250 and 450 mK when varying the resident Ar pressure during deposition. Magnetic shielding designs and simulations are presented for the TIME first-stage SQUIDs. Total axial field suppression is predicted to be 5 × 10^7.

  14. Symmetric tape round REBCO wire with J e (4.2 K, 15 T) beyond 450 A mm-2 at 15 mm bend radius: a viable candidate for future compact accelerator magnet applications

    Science.gov (United States)

    Kar, Soumen; Luo, Wenbo; Ben Yahia, Anis; Li, Xiaofen; Majkic, Goran; Selvamanickam, Venkat

    2018-04-01

    Round REBCO (RE = rare earth) wires of 1.6-1.85 mm diameter have been fabricated using ultrathin REBCO tapes where the superconductor film is positioned near the geometric center. Such symmetric tape round (STAR) wires exhibit excellent tolerance to bend strain with a critical current retention of more than 97% when bent to a radius of 15 mm. A 1.6 mm diameter REBCO STAR wire made with six 2.5 mm wide symmetric tapes reached an engineering current density (J e) of 454 A mm-2 at 4.2 K in a background field of 15 T at a bend radius of 15 mm. Such superior performance at a small bend radius can enable fabrication of future accelerator magnets, operating at magnetic fields above 20 T.

  15. Nimbus-2 High-Resolution Infrared Radiometer (HRIR) Imagery of Cloud Cover at Night on 70 mm Film V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The HRIRN2IM data product contains scanned negatives of photofacsimile 70mm film strips from the Nimbus-2 High-Resolution Infrared Radiometer. The images contain...

  16. Tracking chamber made of 15-mm mylar drift tubes

    Science.gov (United States)

    Kozhin, A.; Borisov, A.; Bozhko, N.; Fakhrutdinov, R.; Plotnikov, I.

    2017-05-01

    We are presenting a drift chamber composed from three layers of mylar drift tubes with outer diameter 15 mm. The pipe is made of strip of mylar film 125 micrometers thick covered with aluminium from the both sides. A strip of mylar is wrapped around the mandrel. Pipe is created by ultrasonic welding. A single drift tube is self-supported structure withstanding 350 g wire tension without supports and internal overpressure. About 400 such tubes were assembled. Design, quality control procedures of the drift tubes are described. Seven chambers were glued from these tubes of 560 mm length. Each chamber consists of 3 layers, 16 tubes per layer. Several chambers were tested with cosmic rays. Results of the tests, counting rate plateau and coordinate resolution are presented.

  17. Tracking chamber made of 15-mm mylar drift tubes

    International Nuclear Information System (INIS)

    Kozhin, A.; Borisov, A.; Bozhko, N.; Fakhrutdinov, R.; Plotnikov, I.

    2017-01-01

    We are presenting a drift chamber composed from three layers of mylar drift tubes with outer diameter 15 mm. The pipe is made of strip of mylar film 125 micrometers thick covered with aluminium from the both sides. A strip of mylar is wrapped around the mandrel. Pipe is created by ultrasonic welding. A single drift tube is self-supported structure withstanding 350 g wire tension without supports and internal overpressure. About 400 such tubes were assembled. Design, quality control procedures of the drift tubes are described. Seven chambers were glued from these tubes of 560 mm length. Each chamber consists of 3 layers, 16 tubes per layer. Several chambers were tested with cosmic rays. Results of the tests, counting rate plateau and coordinate resolution are presented.

  18. Doing It Yourself: A Handbook on Independent Film Distribution.

    Science.gov (United States)

    Reichert, Julia

    Written by filmmakers with five years experience as part of a cooperative for the distribution of feminist films, this handbook is designed primarily to instruct filmmakers on how to distribute their films and to assess whether self-distribution is advisable. Mainly non-theatrical use of 16mm films is discussed, with emphasis on educational…

  19. Evaluating Student Self-Assessment through Video-Recorded Patient Simulations.

    Science.gov (United States)

    Sanderson, Tammy R; Kearney, Rachel C; Kissell, Denise; Salisbury, Jessica

    2016-08-01

    The purpose of this pilot study was to determine if the use of a video-recorded clinical session affects the accuracy of dental hygiene student self-assessment and dental hygiene instructor feedback. A repeated measures experiment was conducted. The use of the ODU 11/12 explorer was taught to students and participating faculty through video and demonstration. Students then demonstrated activation of the explorer on a student partner using the same technique. While faculty completed the student assessment in real time, the sessions were video recorded. After completing the activation of the explorer, students and faculty completed an assessment of the student's performance using a rubric. A week later, both students and faculty viewed the video of the clinical skill performance and reassessed the student's performance using the same rubric. The student videos were randomly assigned a number, so faculty reassessed the performance without access to the student's identity or the score that was initially given. Twenty-eight students and 4 pre-clinical faculty completed the study. Students' average score was 4.68±1.16 on the first assessment and slightly higher 4.89±1.45 when reviewed by video. Faculty average scores were 5.07±2.13 at the first assessment and 4.79±2.54 on the second assessment with the video. No significant differences were found between the differences in overall scores, there was a significant difference in the scores of the grading criteria compared to the expert assessment scores (p=0.0001). This pilot study shows that calibration and assessment without bias in education is a challenge. Analyzing and incorporating new techniques can result in more exact assessment of student performance and self-assessment. Copyright © 2016 The American Dental Hygienists’ Association.

  20. Fabrication and Characterization of PZT Thick Films for Sensing and Actuation

    Directory of Open Access Journals (Sweden)

    Kuo-Ching Kuo

    2007-04-01

    Full Text Available Lead Zirconate Titanate oxide (PZT thick films with thicknesses of up to 10 μmwere developed using a modified sol-gel technique. Usually, the film thickness is less than1 μm by conventional sol-gel processing, while the electrical charge accumulation whichreveals the direct effect of piezoelectricity is proportional to the film thickness and thereforerestricted. Two approaches were adopted to conventional sol-gel processing – precursorconcentration modulation and rapid thermal annealing. A 10 μm thick film was successfullyfabricated by coating 16 times via this technique. The thickness of each coating layer wasabout 0.6 μm and the morphology of the film was dense with a crack-free area as large as 16mm2. In addition, the structure, surface morphology and physical properties werecharacterized by X-ray diffraction (XRD, scanning electron microscopy (SEM and atomicforce microscopy (AFM and electrical performance. The dielectric constant and hysteresisloops were measured as electric characteristics. This study investigates the actuation andsensing performance of the vibrating structures with the piezoelectric thick film. Theactuation tests demonstrated that a 4 mm x 4 mm x 6.5 μm PZT film drove a 40 mm x 7 mmx 0.5 mm silicon beam as an actuator. Additionally, it generated an electrical signal of 60mVpp as a sensor, while vibration was input by a shaker. The frequencies of the first twomodes of the beam were compared with the theoretical values obtained by Euler-Bernoullibeam theory. The linearity of the actuation and sensing tests were also examined.

  1. Gastrointestinal digital fluoroscopy: Comparison of digital pulsed progressive readout images with 100-mm spot films

    International Nuclear Information System (INIS)

    Steiner, E.; Ferrucci, J.T.; Mueller, P.R.; Hahn, P.F.

    1987-01-01

    New developments in pulsed progressive readout (PPR) techniques allow short, extremely intense pulses of radiation to be used to produce a latent image which is then progressively read off the video camera and placed in 1,024 x 1,024-pixel digital storage. The resulting image is produced by a 10-20-msec pulse, reducing motion artifact to below that achievable with conventional spot film techniques, with a potential for 50%-95% dose reduction. This technique of reducing motion artifact is ideal for digital applications in gastrointestinal radiology. The authors compared 10-mm spot films and PPR digital radiographs of 86 anatomic regions in 43 patients undergoing routine barium enema and cholangiographic examinations. Parameters evaluated included display of normal and pathologic features, image contrast, and resolution. The benefits of the PPR technique include postprocessing to evaluate low contrast region and the potential for significant dose reduction

  2. Video-recorded simulated patient interactions: can they help develop clinical and communication skills in today's learning environment?

    Science.gov (United States)

    Seif, Gretchen A; Brown, Debora

    2013-01-01

    It is difficult to provide real-world learning experiences for students to master clinical and communication skills. The purpose of this paper is to describe a novel instructional method using self- and peer-assessment, reflection, and technology to help students develop effective interpersonal and clinical skills. The teaching method is described by the constructivist learning theory and incorporates the use of educational technology. The learning activities were incorporated into the pre-clinical didactic curriculum. The students participated in two video-recording assignments and performed self-assessments on each and had a peer-assessment on the second video-recording. The learning activity was evaluated through the self- and peer-assessments and an instructor-designed survey. This evaluation identified several themes related to the assignment, student performance, clinical behaviors and establishing rapport. Overall the students perceived that the learning activities assisted in the development of clinical and communication skills prior to direct patient care. The use of video recordings of a simulated history and examination is a unique learning activity for preclinical PT students in the development of clinical and communication skills.

  3. Spanish-Language Film Catalog 1969-1970 (Catalogo de Peliculas en Espanol 1969-1970).

    Science.gov (United States)

    Agency for International Development (Dept. of State), Washington, DC.

    This annotated catalogue of 16 mm educational films in Spanish covers a broad spectrum of topics. The extensive coverage accorded business management, child development, dental hygiene, education, family planning, health, industrial safety, labor, metalwork, sanitation, self-help, and teaching suggests the general type of film listed. Films are…

  4. Observing the Testing Effect using Coursera Video-recorded Lectures: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Paul Zhihao eYONG

    2016-01-01

    Full Text Available We investigated the testing effect in Coursera video-based learning. One hundred and twenty-three participants either (a studied an instructional video-recorded lecture four times, (b studied the lecture three times and took one recall test, or (c studied the lecture once and took three tests. They then took a final recall test, either immediately or a week later, through which their learning was assessed. Whereas repeated studying produced better recall performance than did repeated testing when the final test was administered immediately, testing produced better performance when the final test was delayed until a week after. The testing effect was observed using Coursera lectures. Future directions are documented.

  5. Professor Camillo Negro's Neuropathological Films.

    Science.gov (United States)

    Chiò, Adriano; Gianetto, Claudia; Dagna, Stella

    2016-01-01

    Camillo Negro, Professor in Neurology at the University of Torino, was a pioneer of scientific film. From 1906 to 1908, with the help of his assistant Giuseppe Roasenda and in collaboration with Roberto Omegna, one of the most experienced cinematographers in Italy, he filmed some of his patients for scientific and educational purposes. During the war years, he continued his scientific film project at the Military Hospital in Torino, filming shell-shocked soldiers. In autumn 2011, the Museo Nazionale del Cinema, in partnership with the Faculty of Neurosciences of the University of Torino, presented a new critical edition of the neuropathological films directed by Negro. The Museum's collection also includes 16 mm footage probably filmed in 1930 by Doctor Fedele Negro, Camillo's son. One of these films is devoted to celebrating the effects of the so-called "Bulgarian cure" on Parkinson's disease.

  6. Chernobyl: Chronicle of difficult weeks [videorecording

    Energy Technology Data Exchange (ETDEWEB)

    Volodymyr, S

    1987-07-01

    1. Chernobyl : chronicle of difficult weeks. Shevchenko's film crew was the first in the disaster zone following the meltdown of the core of the Chernobyl nuclear power plant in 1986. They shot continuously for more than three months. Portions of the film are exposed with white blotches - a radiation leakage. The film demonstrates how authorities and volunteers dealt with the accident, shows the efforts to get the fire under control, to take care of patients with radiation injuries, and to evacuate about 100,000 inhabitants of the area. 2. The BAM zone : permanent residents. The Baikal-Amur Mainline (BAM) railroad in Siberia is called the longest monument to the stagnation of the Brezhnev years. The film shows the lives and fates of the people in contrast to the marches and songs praising the project.

  7. The research on noise equivalent quanta and detective quantum efficiency of screen-film system

    International Nuclear Information System (INIS)

    Xie Jingdong; Wang Changyuan; Yuan Yude; Zhang Menglong; Wang Jian; Zheng Hao; Sun Yong

    2002-01-01

    Objective: To examine the noise equivalent quanta (NEQ) and detective quantum efficiency (DQE) of screen-film system. Methods: Green 400 screen-Kodak film and CaWO 4 screen-Fuji film were used in the study. The characteristic curves were obtained by distance method. The square wave technique was employed to determine the modulation transfer function (MTF). The Wiener spectrum (WS) was determined by Fourier analysis on uniformly exposed films. The NEQ and DQE were calculated from the characteristic curve slope, MTF, and WS measurements. Results: (1) The NEQ value of Green 400 screen-Kodak film system was 1.48 x 10 6 mm -2 when the spatial frequency was 0.6 cycles/mm, and it was 0.65 times larger than that of CaWO 4 screen-Fuji film system; The NEQ value of Green 400 screen-Kodak film system was 0.329 x 10 4 mm -2 when the spatial frequency was 4.0 cycles/mm, and it was 1.55 times larger than that of CaWO 4 screen-Fuji film system. (2) The DQE value of Green 400 screen-Kodak film system was 0.224 when the spatial frequency was 0.6 cycles/mm, and it was 1.6 times larger than that of CaWO 4 screen-Fuji film system; The DQE value of Green 400 screen-Kodak film system was 0.052 when the spatial frequency was 4.0 cycles/mm, and it was 3.7 times larger than that of CaWO 4 screen-Fuji film system. Conclusion: The Green 400 Screen-Kodak film system has superior NEQ when the spatial frequency was more than 3.0 cycles/mm and has superior DQE among the total spatial frequency in comparison with CaWO 4 screen-Fuji film system

  8. Silicon-Film(TM) Solar Cells by a Flexible Manufacturing System: Final Report, 16 April 1998 -- 31 March 2001

    Energy Technology Data Exchange (ETDEWEB)

    Rand, J.

    2002-02-01

    This report describes the overall goal to engineer and develop flexible manufacturing methods and equipment to process Silicon-Film solar cells and modules. Three major thrusts of this three-year effort were to: develop a new larger-area (208 mm x 208 mm) Silicon-Film solar cell, the APx-8; construct and operate a new high-throughput wafer-making system; and develop a 15-MW single-thread manufacturing process. Specific technical accomplishments from this period are: Increase solar cell area by 80%, increase the generation capacity of a Silicon-Film wafer-making system by 350%, use a new in-line HF etch system in solar cell production, design and develop an in-line NaOH etch system, eliminate cassettes in solar cell processing, and design a new family of module products.

  9. Mammographic microcalcifications: Detection with xerography, screen-film, and digitized film display

    International Nuclear Information System (INIS)

    Smathers, R.L.; Bush, E.; Drace, J.; Stevens, M.; Sommer, F.G.; Brown, B.W.; Karras, B.

    1986-01-01

    Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray tube (CRT) monitors. Six radiologists independently counted the microcalcifications on the xeromammograms, the screen-film mammograms, and the digitized film mammograms. The xeromammograms were examined with a magnifying glass; the screen-film images were examined with a magnifying glass and by hot light; and the digitized-film images were examined by electronic magnification and image processing. The bone speck size that corresponded to a mean 50% detectability level for each technique was as follows: xeromammography, 0.550 mm; digitized film, 0.573 mm; and screen-film, 0.661 mm. We postulate that electronic magnification and image processing with edge enhancement can improve the capability of screen-film mammography to enhance the detection of microcalcifications

  10. SU-E-T-443: Geometric Uncertainties in Eye Plaque Dosimetry for a Fully Loaded 16 Mm COMS Plaque

    International Nuclear Information System (INIS)

    Morrison, H; Menon, G; Jans, H; Larocque, M; Sloboda, R

    2015-01-01

    Purpose: To determine the effect of geometric uncertainties in the seed positions in a COMS eye plaque on the central axis (CAX) dose. Methods: A Silastic insert was placed into a photopolymer 3D printed 16 mm COMS plaque, which was then positioned onto a custom-designed PMMA eye phantom. High resolution 3D images were acquired of the setup using a Siemens Inveon microPET/CT scanner. Images were acquired with the plaque unloaded and loaded with IsoAid I-125 seed shells (lack of silver core to minimize metal artifacts). Seed positions and Silastic thickness beneath each slot were measured. The measured seed coordinates were used to alter the seed positions within a standard 16 mm COMS plaque in Plaque Simulator v5.7.3 software. Doses along the plaque CAX were compared for the original and modified plaque coordinates using 3.5 mCi seeds with treatment times set to deliver 70 Gy to tumour apexes of 3.5, 5, and 10 mm height. Results: The majority of seeds showed length-wise displacement, and all seeds showed displacement radially outward from the eye center. The average radial displacement was 0.15 mm larger than the expected 1.4 mm offset, approximately half of which was due to increased Silastic thickness beneath each slot. The CAX doses for the modified seed positions were consistently lower for all tumour heights due to geometric displacement of the seeds; dose differences were found to increase to a maximum of 2.6% at a depth of ∼10 mm, after which they decreased due to the inverse square dose fall-off minimizing this effect. Conclusion: This work presents initial results of a broader dosimetric uncertainty evaluation for fully loaded COMS eye plaques and demonstrates the effects of seed positioning uncertainties. The small shifts in seed depths had noticeable effects on the CAX doses indicating the importance of careful Silastic loading. Funding provided by Alberta Cancer Foundation Grant #26655, Vanier Canada Graduate Scholarship, and Alberta Innovates Health

  11. Study of optical properties of vacuum evaporated carbon nanotube containing Se80Te16Cu4 thin films

    Science.gov (United States)

    Upadhyay, A. N.; Tiwari, R. S.; Singh, Kedar

    2016-08-01

    Thin films of Se80Te16Cu4 glassy alloy and 3 wt.% of carbon nanotubes (CNTs) containing Se80Te16Cu4 glassy composite were deposited on clean glass substrate by thermal evaporation technique. The scanning electron microscope and energy dispersive x-ray analysis were performed to investigate the surface morphology and elemental composition of as synthesised samples. The reflectance and transmittance spectra of as-deposited thin films were recorded (200-1100 nm) by using UV/VIS/NIR spectrophotometer. The optical band gap and optical constants such as absorption coefficient (α), refractive index (n) and extinction coefficient (k) of Se80Te16Cu4 and 3 wt.% CNTs-Se80Te16Cu4 glassy composite thin films were calculated. It is observed that optical properties alter due to CNTs incorporation in Se80Te16Cu4 glassy alloy. Effect on optical properties due to CNTs incorporation can be explained in terms of concentration of unsaturated bonds/defects in the localised states.

  12. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography.

    Science.gov (United States)

    Stuberg, W A; Colerick, V L; Blanke, D J; Bruce, W

    1988-08-01

    The purpose of this study was to compare a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography in a gait analysis laboratory. Ten children with a diagnosis of cerebral palsy (means age = 8.8 +/- 2.7 years) and 9 healthy children (means age = 8.9 +/- 2.4 years) participated in the study. Stride length, walking velocity, and goniometric measurements of the hip, knee, and ankle were recorded using the two gait analysis methods. A multivariate analysis of variance was used to determine significant differences between the data collected using the two methods. Pearson product-moment correlation coefficients were determined to examine the relationship between the measurements recorded by the two methods. The consistency of performance of the subjects during walking was examined by intraclass correlation coefficients. No significant differences were found between the methods for the variables studied. Pearson product-moment correlation coefficients ranged from .79 to .95, and intraclass coefficients ranged from .89 to .97. The clinical gait analysis method was found to be a valid tool in comparison with 16-mm cinematography for the variables that were studied.

  13. Plasticizer effect on the properties of biodegradable blend film from rice starch-chitosan

    Directory of Open Access Journals (Sweden)

    Thawien Bourtoom

    2008-04-01

    Full Text Available The properties of biodegradable blend film from rice starch-chitosan with different plasticizers were determined. Three plasticizers comprising sorbitol (SOR, glycerol (GLY and polyethylene glycol (PEG were studied over a range of concentration from 20 to 60%. Increasing concentration of these plasticizers resulted in decreased tensile strength (TS concomitant with an increase in elongation at break (E, water vapor permeability (WVP and film solubility (FS. SOR plasticized films were the most brittle, with the highest tensile strength (TS, 26.06 MPa. However, its effect on WVP was low (5.45 g.mm/m2.day.kPa. In contrast, GLY and PEG plasticized films had a flexible structure contradictory to a low TS (14.31MPa and 16.14MPa, respectively providing a high WVP (14.52 g.mm/m2.day.kPa and 14.69 g.mm/m2.day.kPa, respectively. SOR plasticized films, demonstrated little higher FS compared to PEG and GLY plasticized films but not significant different (p<0.05. The color of biodegradable blend film from rice starch-chitosan was more affected by the concentration of the plasticizer used than by its type. Nine moisture sorption models were applied to experimental data. Moisture content of the film increased at elevated water activity. The time to reach equilibrium moisture content (EMC was about 20-24 days at lower humidity and 13-16 days at higher humidities. The EMC of glycerol and sorbitol rice starchchitosan biodegradable blend films showed a logarithmic increase at above 0.59 aw and reached the highest moisture content of 51.46% and 42.97 % at 0.95 aw, whereas PEG rice starch-chitosan biodegradable blend films did not show much increase in moisture content.

  14. DETERMINATION OF LIQUID FILM THICKNESS FOLLOWING DRAINING OF CONTACTORS, VESSELS, AND PIPES IN THE MCU PROCESS

    International Nuclear Information System (INIS)

    Poirier, M; Fernando Fondeur, F; Samuel Fink, S

    2006-01-01

    The Department of Energy (DOE) identified the caustic side solvent extraction (CSSX) process as the preferred technology to remove cesium from radioactive waste solutions at the Savannah River Site (SRS). As a result, Washington Savannah River Company (WSRC) began designing and building a Modular CSSX Unit (MCU) in the SRS tank farm to process liquid waste for an interim period until the Salt Waste Processing Facility (SWPF) begins operations. Both the solvent and the strip effluent streams could contain high concentrations of cesium which must be removed from the contactors, process tanks, and piping prior to performing contactor maintenance. When these vessels are drained, thin films or drops will remain on the equipment walls. Following draining, the vessels will be flushed with water and drained to remove the flush water. The draining reduces the cesium concentration in the vessels by reducing the volume of cesium-containing material. The flushing, and subsequent draining, reduces the cesium in the vessels by diluting the cesium that remains in the film or drops on the vessel walls. MCU personnel requested that Savannah River National Laboratory (SRNL) researchers conduct a literature search to identify models to calculate the thickness of the liquid films remaining in the contactors, process tanks, and piping following draining of salt solution, solvent, and strip solution. The conclusions from this work are: (1) The predicted film thickness of the strip effluent is 0.010 mm on vertical walls, 0.57 mm on horizontal walls and 0.081 mm in horizontal pipes. (2) The predicted film thickness of the salt solution is 0.015 mm on vertical walls, 0.74 mm on horizontal walls, and 0.106 mm in horizontal pipes. (3) The predicted film thickness of the solvent is 0.022 mm on vertical walls, 0.91 mm on horizontal walls, and 0.13 mm in horizontal pipes. (4) The calculated film volume following draining is: (a) Salt solution receipt tank--1.6 gallons; (b) Salt solution feed

  15. Radiation dose in hysterosalpingography: modern 100mm fluorography vs. full-scale radiography

    International Nuclear Information System (INIS)

    Seppaenen, S.; Lehtinen, E.; Holli, H.

    1978-01-01

    Radiation doses of modern 100 mm fluorography and full-scale radiography were compared experimentally and applied to hysterosalpingography. It was determined that 100 mm fluorography reduced the doses by 28 to 29 percent per exposure and 37 to 47 percent per examination compared with full-scale radiography performed with fast tungstate screens in identical conditions (70 to 80 kV, 400 mA). The dose during one minute of videofluoroscopy was equivalent to the doses produced by one exposure in full-scale filming and three to four exposures in 100 mm filming. Although electronic magnification in 100 mm fluorography increases the doses by two or threefold, these are still less than the doses in full-scale radiography

  16. Meteor Film Recording with Digital Film Cameras with large CMOS Sensors

    Science.gov (United States)

    Slansky, P. C.

    2016-12-01

    In this article the author combines his professional know-how about cameras for film and television production with his amateur astronomy activities. Professional digital film cameras with high sensitivity are still quite rare in astronomy. One reason for this may be their costs of up to 20 000 and more (camera body only). In the interim, however,consumer photo cameras with film mode and very high sensitivity have come to the market for about 2 000 EUR. In addition, ultra-high sensitive professional film cameras, that are very interesting for meteor observation, have been introduced to the market. The particular benefits of digital film cameras with large CMOS sensors, including photo cameras with film recording function, for meteor recording are presented by three examples: a 2014 Camelopardalid, shot with a Canon EOS C 300, an exploding 2014 Aurigid, shot with a Sony alpha7S, and the 2016 Perseids, shot with a Canon ME20F-SH. All three cameras use large CMOS sensors; "large" meaning Super-35 mm, the classic 35 mm film format (24x13.5 mm, similar to APS-C size), or full format (36x24 mm), the classic 135 photo camera format. Comparisons are made to the widely used cameras with small CCD sensors, such as Mintron or Watec; "small" meaning 12" (6.4x4.8 mm) or less. Additionally, special photographic image processing of meteor film recordings is discussed.

  17. Chernobyl as viewed from the 90's [videorecording

    International Nuclear Information System (INIS)

    1991-01-01

    It is admitted in this film that after the Chernobyl accident there was a lot of unnecessary secrecy which created a great deal of confusion among the public. The film shows the investigations within the reactor and the efforts undertaken to put the remnants of the reactor into a safe state, including the construction of the sarcophagus which was built around it. The film also presents the radiological environmental monitoring, as well as the health aspects of Chernobyl

  18. Chernobyl as viewed from the 90's [videorecording

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-07-01

    It is admitted in this film that after the Chernobyl accident there was a lot of unnecessary secrecy which created a great deal of confusion among the public. The film shows the investigations within the reactor and the efforts undertaken to put the remnants of the reactor into a safe state, including the construction of the sarcophagus which was built around it. The film also presents the radiological environmental monitoring, as well as the health aspects of Chernobyl.

  19. Thin films for emerging applications v.16

    CERN Document Server

    Francombe, Maurice H

    1992-01-01

    Following in the long-standing tradition of excellence established by this serial, this volume provides a focused look at contemporary applications. High Tc superconducting thin films are discussed in terms of ion beam and sputtering deposition, vacuum evaporation, laser ablation, MOCVD, and other deposition processes in addition to their ultimate applications. Detailed treatment is also given to permanent magnet thin films, lateral diffusion and electromigration in metallic thin films, and fracture and cracking phenomena in thin films adhering to high-elongation substrates.

  20. Simulation of Thermal Processes in Metamaterial MM-to-IR Converter for MM-wave Imager

    International Nuclear Information System (INIS)

    Zagubisalo, Peter S; Paulish, Andrey G; Kuznetsov, Sergey A

    2014-01-01

    The main characteristics of MM-wave image detector were simulated by means of accurate numerical modelling of thermophysical processes in a metamaterial MM-to-IR converter. The converter represents a multilayer structure consisting of an ultra thin resonant metamaterial absorber and a perfect emissive layer. The absorber consists of a dielectric self-supporting film that is metallized from both sides. A micro-pattern is fabricated from one side. Resonant absorption of the MM waves induces the converter heating that yields enhancement of IR emission from the emissive layer. IR emission is detected by IR camera. In this contribution an accurate numerical model for simulation of the thermal processes in the converter structure was created by using COMSOL Multiphysics software. The simulation results are in a good agreement with experimental results that validates the model. The simulation shows that the real time operation is provided for the converter thickness less than 3 micrometers and time response can be improved by decreasing of the converter thickness. The energy conversion efficiency of MM waves into IR radiation is over 80%. The converter temperature increase is a linear function of a MM-wave radiation power within three orders of the dynamic range. The blooming effect and ways of its reducing are also discussed. The model allows us to choose the ways of converter structure optimization and improvement of image detector parameters

  1. Individualized music played for agitated patients with dementia: analysis of video-recorded sessions.

    Science.gov (United States)

    Ragneskog, H; Asplund, K; Kihlgren, M; Norberg, A

    2001-06-01

    Many nursing home patients with dementia suffer from symptoms of agitation (e.g. anxiety, shouting, irritability). This study investigated whether individualized music could be used as a nursing intervention to reduce such symptoms in four patients with severe dementia. The patients were video-recorded during four sessions in four periods, including a control period without music, two periods where individualized music was played, and one period where classical music was played. The recordings were analysed by systematic observations and the Facial Action Coding System. Two patients became calmer during some of the individualized music sessions; one patient remained sitting in her armchair longer, and the other patient stopped shouting. For the two patients who were most affected by dementia, the noticeable effect of music was minimal. If the nursing staff succeed in discovering the music preferences of an individual, individualized music may be an effective nursing intervention to mitigate anxiety and agitation for some patients.

  2. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm).

    Science.gov (United States)

    Kato, Yasuyuki; Hattori, Koji; Motoki, Manabu; Takahashi, Yosuke; Kotani, Shinsuke; Nishimura, Shinsuke; Shibata, Toshihiko

    2013-07-01

    Controversy exists regarding the optimal operative method or type of prosthesis for patients with a small aortic root. The aim of this retrospective study was to investigate the early and mid-term outcomes of standard aortic valve replacement (AVR) using 16 mm or 18 mm ATS Advanced Performance (AP) or 17 mm St. Jude Medical (SJM) Regent valves for a small aortic root. Between April 2003 and August 2009, 78 patients (age range: 50-86 years; 86% aged > or = 65 years) underwent AVR with 16 mm or 18 mm ATS AP valves (16AP group: n = 21, 18AP group: n = 32), or a 17 mm SJM Regent valve (17Regent group: n = 25). Fifty-six patients (72%) had a body surface area (BSA) of regression was similar among the groups (-30%, -25% and -28% in the 16AP, 17Regent and 18AP groups, respectively; p = 0.844). The early and mid-term results of AVR with 16 mm or 18 mm ATS AP valves, or with a 17 mm SJM Regent valve, were satisfactory. Therefore, standard AVR using these small mechanical prostheses, which avoids the need to enlarge the annulus or to conduct stentless bioprosthesis implantation, might represent an acceptable method, especially in elderly patients with a small aortic root.

  3. Preparation and characterization of electrodeposited SnS:In thin films: Effect of In dopant

    Science.gov (United States)

    Kafashan, Hosein; Balak, Zohre

    2017-09-01

    SnS:In thin films were grown on fluorine doped tin oxide (FTO) substrate by cathodic electrodeposition technique. The solution was containing 2 mM SnCl2 and 16 mM Na2S2O3 and different amounts of 1 mM InCl3 as In-dopant. The pH, bath temperature, deposition time, and deposition potential (E) were fixed at 2.1, 60 °C, 30 min, and - 1 V, respectively. The XRD results showed that the synthesized films were polycrystalline orthorhombic SnS. The XPS results demonstrated that the films were composed of Sn, S and In. According to the FESEM images, an increase in In-dopant concentration leads to a change in morphology from grain-like to sheet-like having a nanoscale thickness of 20-80 nm and fiber-like. The PL spectra of undoped SnS exhibited four emission peaks including a UV peak, two blue emission peaks, and an IR emission peak. According to the UV-Vis spectra, the direct band gap of SnS:In thin films was estimated to be 1.40-1.66 eV.

  4. Loss and benefit of DR system in mass screening for upper GI-tracts. Comparison with an II-TV based DR system and 100-mm roll-film system

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Fujita, Hiroshi.

    1995-01-01

    A 2048 x 2048 matrix II-TV based digital radiography (DR) system, a fully digital imaging system with diagnosis on the CRT monitor, had been introduced to Cancer Institute Hospital for the GI-tracts examinations since January 1990. Furthermore, we had applied it to the mass screening of upper GI-tract since November 1992. In the present study, a retrospective study on clinical evaluation and features of the DR system for the mass screening were investigated and compared with the screening data taken by conventional 100-mm roll-film technique in the previous year. The loss ratios and appearance of the mucosal patterns in upper gastric images were studied as well. Also determined was the reading time of those images in the mass screening situation. It was found that the loss ratio on the subject image information in 100-mm roll-film images was smaller than that in DR images. However, the DR images processed by windowing technique provided the perfect information without partially over or under density area. It was shown that the clinical image quality greatly depended on the radiographic technique by radiologists or technologists rather than on the imaging modality itself employed; even in II/TV-DR system, the radiographic technique is important. Because of some issues, including the size of CRT monitor, eyestrain for CRT monitor, and windowing operation regard to reading system, the reading time of CRT images was 1.44-2.05 times longer than that of 100-mm roll-film images. (author)

  5. Perbaikan Sifat Laju Transmisi Uap Air dan Antibakteri Edible Film dengan Menggunakan Minyak Sawit dan Jeruk Kunci

    Directory of Open Access Journals (Sweden)

    Budi Santoso

    2018-01-01

    Full Text Available The objective of the research was to improve water vapor transmission rate and antibacterial properties of edible film by using red palm oil and Citrus mitis. The research design was factorial completely randomized design with three replications. There were three studies: the addition of Uncaria gambir Roxb extract, palm oil concentration, and pH value at the concentration 0, 1.5, and 3 (% w/v; 0, 1.5, and 3 (% v/v; and 3, 4, 5, and 6 respectively. The results showed that interaction of Uncaria gambir Roxb extract, palm oil and pH had significant effected on solubility of edible film. Interaction of Uncaria gambir Roxb and palm oil had significant effected on thickness, percentage of elongation and solubility of edible film. Interaction of Uncaria gambir Roxb and pH had significant effected on solubility of edible film. Characteristic of edible film was produced thickness 0.15 to 0.28 mm, percentage of elongation 23.33 to 87.78%, solubility 33.9 to 49.16%, water vapor transmission rate 3.43 to 8.52 g.m-2.d-1, and inhibition zone for Staphylococcus aureus 0.2 to 8.2 mm. ABSTRAK Tujuan penelitian adalah untuk memperbaiki laju transmisi uap air dan sifat antibakteri edible film dengan menggunakan minyak sawit dan jeruk kunci. Rancangan penelitian yang digunakan adalah rancangan acak lengkap faktorial dengan tiga kali ulangan. Perlakuan terdiri atas konsentrasi ekstrak gambir; 0, 1,5, dan 3 (% b/v, konsentrasi minyak sawit; 0, 1,5, dan 3 (% v/v, dan pH (3, 4, 5, dan 6. Hasil penelitian menunjukkan bahwa interaksi ekstrak gambir, minyak sawit, dan derajat keasaman (pH berpengaruh nyata terhadap kelarutan edible film. Interaksi ekstrak gambir dengan minyak sawit berpengaruh nyata terhadap ketebalan, persen pemanjangan, dan kelarutan edible film. Interaksi minyak sawit dengan derajat keasaman (pH berpengaruh nyata terhadap kelarutan edible film. Interaksi ekstrak gambir dengan derajat keasaman (pH berpengaruh nyata terhadap kelarutan edible film

  6. Separation of valence states in thin films with mixed V{sub 2}O{sub 5} and V{sub 7}O{sub 16} phases

    Energy Technology Data Exchange (ETDEWEB)

    Huotari, J., E-mail: jonihuot@ee.oulu.fi [Faculty of Information Technology and Electrical Engineering, University of Oulu, P.O. Box 4500, FI-90014 Oulu (Finland); Cao, W. [Research Centre for Molecular Materials, University of Oulu, P.O. Box 3000, FI-90014 Oulu (Finland); Niu, Y. [MAX-lab, Lund University, SE-221 00 Lund (Sweden); Lappalainen, J.; Puustinen, J. [Faculty of Information Technology and Electrical Engineering, University of Oulu, P.O. Box 4500, FI-90014 Oulu (Finland); Pankratov, V. [Research Centre for Molecular Materials, University of Oulu, P.O. Box 3000, FI-90014 Oulu (Finland); Lloyd Spetz, A. [Faculty of Information Technology and Electrical Engineering, University of Oulu, P.O. Box 4500, FI-90014 Oulu (Finland); Department of Physics, Chemistry and Biology, Linköping University, SE-581 83 Linköping (Sweden); Huttula, M. [Research Centre for Molecular Materials, University of Oulu, P.O. Box 3000, FI-90014 Oulu (Finland)

    2016-08-15

    Highlights: • Films have different XPS and NEXAFS spectra depending on the crystal structure. • Difference in oxygen vacancy concentration between the different films is identified. • Connection between high gas sensitivity and surface state of the films is revealed. - Abstract: Among the other applications, vanadium oxide thin films are considered to be excellent candidates for gas sensing. To understand the origins of the sensing capability, we carried out X-ray photoelectron and X-ray absorption spectroscopy measurements to determinate the surface valence states of thin films with mixed V{sub 7}O{sub 16} and V{sub 2}O{sub 5} compounds. Thin films were fabricated by pulsed laser deposition, and the crystal structure and symmetry of the deposited films was studied using grazing incidence X-ray diffraction and Raman spectroscopy. These results together with X-ray photoelectron and absorption spectra showed that the thin-film crystal structures varied between orthorhombic V{sub 2}O{sub 5} phase and another phase of triclinic V{sub 7}O{sub 16}. X-ray photoelectron spectroscopy was used to quantitatively confirm the high amount of V{sup 4+} ions on surfaces of the films, especially of films with V{sub 7}O{sub 16} phase present. This result was confirmed in the quantitative analysis of the V2p near-edge X-ray absorption spectra. Through the observed electronic structures, it was found that in addition to unique crystal structure and morphology, the enhanced gas sensitivity of these layers is attributed to the increase in the amount of surface oxygen vacancies.

  7. Mechanics of Thin Films

    Science.gov (United States)

    1992-02-06

    and the second geometry was that of squat cylinders (diameter 6.4 mm, height 6.4 mm). These two geometries were tested in thermal shock tests, and a...milder [13]. More recently, Lau, Rahman and stressa nce ntrati, tha n films of lmalla rat ve spc Delale calculated the free edge singularity for stress...thickness of 3 mm); the second geometry was that As an example of the shielding effect of thin films, we of squat cylinders (diameter 6.4 mm, height 6.4

  8. Piezoelectric ultrasonic micromotor with 1.5 mm diameter.

    Science.gov (United States)

    Dong, Shuxiang; Lim, Siak P; Lee, Kwork H; Zhang, Jingdong; Lim, Leong C; Uchino, Kenji

    2003-04-01

    A piezoelectric ultrasonic micromotor has been developed using a lead zirconate titanate (PZT) ceramic/metal composite tube stator that was 1.5 mm in diameter and 7 mm in length. The micromotor was operated in its first bending vibration mode (approximately 70 kHz), producing speeds from hundreds to over 2000 rpm in both rotational directions. The maximum torque-output was 45 microN-m, which is far superior to previous PZT thin film-based micromotors. This micromotor showed good reliability and stability for more than 300 hours of continued operation.

  9. Effects of heat input on mechanical properties of metal inert gas welded 1.6 mm thick galvanized steel sheet

    International Nuclear Information System (INIS)

    Rafiqul, M I; Ishak, M; Rahman, M M

    2012-01-01

    It is usually a lot easier and less expensive to galvanize steel before it is welded into useful products. Galvanizing afterwards is almost impossible. In this research work, Galvanized Steel was welded by using the ER 308L stainless steel filler material. This work was done to find out an alternative way of welding and investigate the effects of heat input on the mechanical properties of butt welded joints of Galvanized Steel. A 13.7 kW maximum capacity MIG welding machine was used to join 1.6 mm thick sheet of galvanized steel with V groove and no gap between mm. Heat inputs was gradually increased from 21.06 to 25.07 joules/mm in this study. The result shows almost macro defects free welding and with increasing heat input the ultimate tensile strength and welding efficiency decrease. The Vickers hardness also decreases at HAZ with increasing heat input and for each individual specimen; hardness was lowest in heat affected zone (HAZ), intermediate in base metal and maximum in welded zone. The fracture for all specimens was in the heat affected zone while testing in the universal testing machine.

  10. Effects of heat input on mechanical properties of metal inert gas welded 1.6 mm thick galvanized steel sheet

    Science.gov (United States)

    Rafiqul, M. I.; Ishak, M.; Rahman, M. M.

    2012-09-01

    It is usually a lot easier and less expensive to galvanize steel before it is welded into useful products. Galvanizing afterwards is almost impossible. In this research work, Galvanized Steel was welded by using the ER 308L stainless steel filler material. This work was done to find out an alternative way of welding and investigate the effects of heat input on the mechanical properties of butt welded joints of Galvanized Steel. A 13.7 kW maximum capacity MIG welding machine was used to join 1.6 mm thick sheet of galvanized steel with V groove and no gap between mm. Heat inputs was gradually increased from 21.06 to 25.07 joules/mm in this study. The result shows almost macro defects free welding and with increasing heat input the ultimate tensile strength and welding efficiency decrease. The Vickers hardness also decreases at HAZ with increasing heat input and for each individual specimen; hardness was lowest in heat affected zone (HAZ), intermediate in base metal and maximum in welded zone. The fracture for all specimens was in the heat affected zone while testing in the universal testing machine.

  11. Preparation and characterization of PVA/nanocellulose/Ag nanocomposite films for antimicrobial food packaging.

    Science.gov (United States)

    Sarwar, Muhammad Salman; Niazi, Muhammad Bilal Khan; Jahan, Zaib; Ahmad, Tahir; Hussain, Arshad

    2018-03-15

    Antimicrobial packaging is an area of emerging interest and is rapidly expanding with application of nanotechnology. The present work investigates the effect of nanocellulose (NC) and Ag NPs on the physical, mechanical and thermal properties of PVA nanocomposite films. The tensile strength of PVA was improved from 5.52 ± 0.27 MPa to 12.32 ± 0.61 MPa when filled with 8 wt% of NC. Nanocomposite films exhibited strong antibacterial activity against both Staphylococcus aureus (MRSA) and Escherichia coli (DH5-alpha). The maximum inhibition zone at 0.5 g Ag NPs with 12 wt% NC against DH5-alpha was 14 ± 0.70 mm. While, the maximum inhibition zone at 0.3 g Ag NPs for 16 wt% NC was 13.6 ± 0.68 mm against MRSA. Moreover, nanocomposites films have no cytotoxicity effect on HepG2 and cell viability was more than 90%. Based on mechanical properties and antibacterial potential of the developed nanocomposite films, it can be envisaged to use these films for packaging applications. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Radiation grafting on natural films

    Science.gov (United States)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37-40 N mm-1) and puncture deformation (PD=6.5-9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282-296 N mm-1 and PD of 5.0-5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films.

  13. 16 CFR 1615.1 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... part 1610) and the Standard for the Flammability of Vinyl Plastic Film (16 CFR part 1611); and (4... Clothing Textiles (16 CFR part 1610) and the Standard for the Flammability of Vinyl Plastic Film (16 CFR..., Virginia 22209. This document is also available for inspection at the National Archives and Records...

  14. Performance of ultra-small silicon photomultiplier array with active area of 0.12 mm×0.12 mm

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Wang; Zongde, Chen; Chenhui, Li; Ran, He; Shenyuan, Wang; Baicheng, Li; Ruiheng, Wang; Kun, Liang, E-mail: lk@bnu.edu.cn; Ru, Yang; Dejun, Han

    2015-07-01

    We report the performance of an ultra-small silicon photomultiplier (SiPM) line array with 7 elements of 0.12×0.12 mm{sup 2} in active area, 0.2 mm in pitch and 120 micro cells in one element. The device features an epitaxial bulk quenching resistor concept, demonstrated high geometrical fill factor of 41% and photon detection efficiency (PDE) of 25.4% in the wavelength region between 430 nm and 480 nm while retaining high micro cell density around 10 000 mm{sup −2} and ~3 ns FWHM of dark pulses width; it also demonstrated dark count rate of less than 28.7 kHz, optical crosstalk of the order of 2% to 4%, and excellent photon number discrimination. A 0.15 mm×1.6 mm×1.6 mm lutetium yttrium oxyorthosilicate (LYSO) crystal, corresponding to the width, length and height respectively, was successfully coupled to the 1×7 SiPM array for possible ultra-highly resolved positron emission tomography (PET) applications. This novel type of device has advantages particularly for small active area since the performances, such as PDE and response speed is one of the best among SiPMs with similarly high density of micro cells. It may pave a way for this type of SiPM as a promising pixel position sensitive device in imaging sensor applications. - Highlights: • The ultra-small SiPM line array with active area of 0.12 mm×0.12 mm was presented. • The ultra-small SiPM employs the bulk silicon structure as quenching resistor. • A considerable dynamic range and PDE over 25.4% @ 430 nm to 480 nm were characterized.

  15. Growth of highly oriented La{sub 0.84}Sr{sub 0.16}MnO{sub 3} perovskite films

    Energy Technology Data Exchange (ETDEWEB)

    Chung, B.W.; Brosha, E.L.; Garzon, F.H.; Raistrick, I.D.; Houlton, R.J.; Hawley, M.E. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    1995-10-01

    We have grown thin films of La{sub 0.84}Sr{sub 0.16}MnO{sub 3} on SrTiO{sub 3} (100), MgO (100), CeO{sub 2} (100)/Al{sub 2}O{sub 3}, and (100) oriented yttria-stabilized zirconia (YSZ) substrates by using a 90{degree} off-axis RF magnetron sputtering deposition. X-ray diffraction analysis and ion beam channeling experiments reveal that the deposited films grow epitaxially on SrTiO{sub 3}, biaxially textured on MgO, and highly textured on YSZ. Scanning tunneling microscopy reveals that the thin films possess extremely smooth surfaces. {copyright} 1995 Materials Research Society

  16. Layer-by-layer films containing peptides of the Cry1Ab16 toxin from Bacillus thuringiensis for potential biotechnological applications

    International Nuclear Information System (INIS)

    Plácido, Alexandra; Oliveira Farias, Emanuel Airton de; Marani, Mariela M.; Vasconcelos, Andreanne G.; Mafud, Ana C.; Mascarenhas, Yvonne P.; Eiras, Carla

    2016-01-01

    Cry1Ab16 is a toxin of crystalline insecticidal proteins that has been widely used in genetically modified organisms (GMOs) to gain resistance to pests. For the first time, in this study, peptides derived from the immunogenic Cry1Ab16 toxin (from Bacillus thuringiensis) were immobilized as layer-by-layer (LbL) films. Given the concern about food and environmental safety, a peptide with immunogenic potential, PcL342–354C, was selected for characterization of the electrochemical, optical, and morphological properties. The results obtained by cyclic voltammetry (CV) showed that the peptide have an irreversible oxidation process in electrolyte of 0.1 mol·L"−"1 potassium phosphate buffer (PBS) at pH 7.2. It was also observed that the electrochemical response of the peptide is governed mainly by charge transfer. In an attempt to maximize the electrochemical signal of peptide, it was intercalated with natural (agar, alginate and chitosan) or synthetic polymers (polyethylenimine (PEI) and poly(sodium 4-styrenesulfonate (PSS)). The presence of synthetic polymers on the film increased the electrochemical signal of PcL342–354C up to 100 times. Images by Atomic Force Microscopy (AFM) showed that the immobilized PcL342–354C formed self-assembled nanofibers with diameters ranging from 100 to 200 nm on the polymeric film. By UV–Visible spectroscopy (UV–Vis) it was observed that the ITO/PEI/PSS/PcL342–354C film grows linearly up to the fifth layer, thereafter tending to saturation. X-ray diffraction confirmed the presence on the films of crystalline ITO and amorphous polypeptide phases. In general, the ITO/PEI/PSS/PcL342–354C film characterization proved that this system is an excellent candidate for applications in electrochemical sensors and other biotechnological applications for GMOs and environmental indicators. - Highlights: • Peptides of the Cry1Ab16 toxin for potential biotechnological applications • Optimized LbL film deposition for synergic

  17. Layer-by-layer films containing peptides of the Cry1Ab16 toxin from Bacillus thuringiensis for potential biotechnological applications

    Energy Technology Data Exchange (ETDEWEB)

    Plácido, Alexandra [REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, 431, 4200-072 Porto (Portugal); Oliveira Farias, Emanuel Airton de [Núcleo de Pesquisa em Biodiversidade e Biotecnologia, BIOTEC, Campus Ministro Reis Velloso, CMRV, Universidade Federal do Piauí, UFPI, 64202020 Parnaíba, Piaui (Brazil); Marani, Mariela M. [IPEEC-CENPAT-CONICET, Centro Nacional Patagónico, Consejo Nacional de Investigaciones Científicas y Técnicas, 9120 Puerto Madryn, Chubut (Argentina); Vasconcelos, Andreanne G. [Núcleo de Pesquisa em Biodiversidade e Biotecnologia, BIOTEC, Campus Ministro Reis Velloso, CMRV, Universidade Federal do Piauí, UFPI, 64202020 Parnaíba, Piaui (Brazil); Mafud, Ana C.; Mascarenhas, Yvonne P. [Instituto de Física de São Carlos, Universidade de São Paulo, USP, 13566-590 São Carlos, SP (Brazil); Eiras, Carla [Núcleo de Pesquisa em Biodiversidade e Biotecnologia, BIOTEC, Campus Ministro Reis Velloso, CMRV, Universidade Federal do Piauí, UFPI, 64202020 Parnaíba, Piaui (Brazil); Laboratório de Materiais Avançados, LIMAV, Engenharia de Materiais, Centro de Tecnologia, CT, Universidade Federal do Piauí, UFPI, 64049550 Teresina, Piaui (Brazil); and others

    2016-04-01

    Cry1Ab16 is a toxin of crystalline insecticidal proteins that has been widely used in genetically modified organisms (GMOs) to gain resistance to pests. For the first time, in this study, peptides derived from the immunogenic Cry1Ab16 toxin (from Bacillus thuringiensis) were immobilized as layer-by-layer (LbL) films. Given the concern about food and environmental safety, a peptide with immunogenic potential, PcL342–354C, was selected for characterization of the electrochemical, optical, and morphological properties. The results obtained by cyclic voltammetry (CV) showed that the peptide have an irreversible oxidation process in electrolyte of 0.1 mol·L{sup −1} potassium phosphate buffer (PBS) at pH 7.2. It was also observed that the electrochemical response of the peptide is governed mainly by charge transfer. In an attempt to maximize the electrochemical signal of peptide, it was intercalated with natural (agar, alginate and chitosan) or synthetic polymers (polyethylenimine (PEI) and poly(sodium 4-styrenesulfonate (PSS)). The presence of synthetic polymers on the film increased the electrochemical signal of PcL342–354C up to 100 times. Images by Atomic Force Microscopy (AFM) showed that the immobilized PcL342–354C formed self-assembled nanofibers with diameters ranging from 100 to 200 nm on the polymeric film. By UV–Visible spectroscopy (UV–Vis) it was observed that the ITO/PEI/PSS/PcL342–354C film grows linearly up to the fifth layer, thereafter tending to saturation. X-ray diffraction confirmed the presence on the films of crystalline ITO and amorphous polypeptide phases. In general, the ITO/PEI/PSS/PcL342–354C film characterization proved that this system is an excellent candidate for applications in electrochemical sensors and other biotechnological applications for GMOs and environmental indicators. - Highlights: • Peptides of the Cry1Ab16 toxin for potential biotechnological applications • Optimized LbL film deposition for synergic

  18. Chernobyl - A chronicle of difficult weeks [videorecording

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-07-01

    The film demonstrates how authorities and volunteers dealt with the accident at the nuclear power plant at Chernobyl in the Ukraine. The efforts to get the fire under control, to take care of patients with radiation injuries, and to evacuate about 100,000 inhabitants of the area, are shown.

  19. Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors

    International Nuclear Information System (INIS)

    Tsai, J.-S.; Rivard, Mark J.; Engler, Mark J.; Mignano, John E.; Wazer, David E.; Shucart, William A.

    2003-01-01

    Though the 4 mm Gamma Knife helmet is used routinely, there is disagreement in the Gamma Knife users community on the value of the 4 mm helmet relative output factor. A range of relative output factors is used, and this variation may impair observations of dose response and optimization of prescribed dose. To study this variation, measurements were performed using the following radiation detectors: silicon diode, diamond detector, radiographic film, radiochromic film, and TLD cubes. To facilitate positioning of the silicon diode and diamond detector, a three-dimensional translation micrometer was used to iteratively determine the position of maximum detector response. Positioning of the films and TLDs was accomplished by manufacturing custom holders for each technique. Results from all five measurement techniques indicate that the 4 mm helmet relative output factor is 0.868±0.014. Within the experimental uncertainties, this value is in good agreement with results obtained by other investigators using diverse techniques

  20. Radiation grafting on natural films

    International Nuclear Information System (INIS)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37–40 N mm −1 ) and puncture deformation (PD=6.5–9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282–296 N mm −1 and PD of 5.0–5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films. - Highlights: • Irradiation of zein

  1. A reusable OSL-film for 2D radiotherapy dosimetry

    Science.gov (United States)

    Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt

    2017-11-01

    Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film’s reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after ‘beam on’ or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities  ⩽2.6%, a linear dose response (0-32 Gy), a linear signal decay (0.5% min-1) over the 20 min measured, and limited angular dependence  ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film’s measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([-1.6%, 2.1%] versus [-2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after

  2. Droplet ejection and sliding on a flapping film

    Directory of Open Access Journals (Sweden)

    Xi Chen

    2017-03-01

    Full Text Available Water recovery and subsequent reuse are required for human consumption as well as industrial, and agriculture applications. Moist air streams, such as cooling tower plumes and fog, represent opportunities for water harvesting. In this work, we investigate a flapping mechanism to increase droplet shedding on thin, hydrophobic films for two vibrational cases (e.g., ± 9 mm and 11 Hz; ± 2 mm and 100 Hz. Two main mechanisms removed water droplets from the flapping film: vibrational-induced coalescence/sliding and droplet ejection from the surface. Vibrations mobilized droplets on the flapping film, increasing the probability of coalescence with neighboring droplets leading to faster droplet growth. Droplet departure sizes of 1–2 mm were observed for flapping films, compared to 3–4 mm on stationary films, which solely relied on gravity for droplet removal. Additionally, flapping films exhibited lower percentage area coverage by water after a few seconds. The second removal mechanism, droplet ejection was analyzed with respect to surface wave formation and inertia. Smaller droplets (e.g., 1-mm diameter were ejected at a higher frequency which is associated with a higher acceleration. Kinetic energy of the water was the largest contributor to energy required to flap the film, and low energy inputs (i.e., 3.3 W/m2 were possible. Additionally, self-flapping films could enable novel water collection and condensation with minimal energy input.

  3. Film dosimetry analyses on the effect of gold shielding for Iodine-125 eye plaque therapy for choroidal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Wu, A. (Department of Radiation Oncology, University of Pittsburgh, School of Medicine, Joint Radiation Oncology Center and Pittsburgh Cancer Institute, Pittsburgh, PA (USA)); Krasin, F. (Department of Radiation Oncology, Tufts University School of Medicine, New England Medical Center, Boston, MA (USA))

    1990-09-01

    One of the methods currently being used to treat choroidal melanoma employs an episcleral plaque containing I-125 radioactive seeds. However, comprehensive dosimetry studies on the plaque are scarce and controversial. For this work, we use film to study the dosimetry outside the lip of the gold shield of the eye plaque. This lip around the gold shield was made to protect the critical structures behind and adjacent to the lesion. Since the changes of energy spectrum of I-125 in tissue are negligible, film dosimetry seems to be a logical choice because of high spatial resolution required around the lip of the gold plaque. For this study, we first established an H and D curve with dose expressed in a unit of specific dose rate constant. This avoids absolute dose measurements. All film density measurements are made with a 1-mm aperture scan, normalized to the density at the prescription point for tumor of 3--5-mm apical height, i.e., 5 mm from the interior surface of sclera, and converted to percentage isodose curves. With a gold shield, it is found that when the plaque is placed against the optical nerve, the optical disk and macula, located at 2 mm outside the lip, on the exterior surface of sclera, may receive 85% of the prescription dose for a 12-mm plaque and 58% for a 16-mm plaque. For tumors of 8-mm apical height, the optical nerve would receive more than the prescription dose.

  4. Portal film charts for a 6 MV linear accelerator

    International Nuclear Information System (INIS)

    Faermann, S.; Regev, E.; Leser, Y.

    1990-01-01

    Localization errors frequently arise in the portal film technique due to over-or underdevelop films, for high energy radiotherapy machines. To guarantee the accuracy and reproducibility of the localization film technique portal film charts were introduced into the routine planning for the Mevatron 6MV linear accelerator of the Beilinson Radiotherapy Dept. Maintaining reproducible film processor conditions, two films were used: medical X-ray film Curix RPI Agfa and localization film X-OMAT TL Kodak, combined with front and rear copper screens of 0.5 mm thickness each. The sensitometric curves for each film-screen combination were obtained (optical density as function of cassette dose). The least square fitted O.D. curve was used to obtain the cassette dose which produces an O.D. of 1.6. A theoretical equation for the calculation of the dose at the cassette positions, beyond a water phantom, as function of field size, SSD, patient thickness and patient to cassette separation, was experimentally checked with a 0.6 cc Farmer ionization chamber coupled to a 2570 Farmer dosimeter. As a result portal film charts (expressed in MU) were constructed as a function of FS, air-gap and patient-thickness, and the best partition dose for the double-exposure technique was also established. The patients dose in the double exposure technique was compared to that delivered in diagnostic radiology procedures. (author)

  5. POTENSI EDIBLE FILM ANTIMIKROBA SEBAGAI PENGAWET DAGING

    Directory of Open Access Journals (Sweden)

    Maskiyah (Maskiyah

    2015-06-01

    Full Text Available Fresh meat are highly perishable due to their enriched nutrient composition which is easily contaminated by almost any microorganisms. The application of antimicrobial edible films is one of the effective method to extend the shelf life of fresh meat. This study aimed to get antimicrobial edible films formula that have the potential to preserve fresh meat. The study consisted of several steps: 1 research for making a fresh garlic extract, 2 extraction of gelatin from chicken feet, 3 formulation and manufacturing of antimicrobial edible films and 4 the application of edible films on fresh meat. Gelatin-based antimicrobial edible films was the best one that can be applied on fresh meat. Characteristics of the antimirobial edible film: color L 97.28; elongation: 20 mm; tensile strength <0.1 kgf; thickness 0.06 mm; WVTR 15.49 g/(mm.jam; Aw 0.526; moisture content: 22.73%, and has antimicrobial characteristic because of it’s inhibition ability to the growth of S. aureus and E. coli. (Key words: Antimicrobial, Edible film, Meat

  6. Effect of displacement on resistance and capacitance of polyaniline film

    International Nuclear Information System (INIS)

    Karimov, Khasan Sanginovich; Saeed, Muhammad Tariq; Khalid, Fazal Ahmad; Moiz, Syed Abdul

    2011-01-01

    This paper investigates the properties of displacement sensors based on polyaniline (PANI) films. About 1 wt% of PANI micropowder is mixed and stirred in a solution of 90 wt% water and 10 wt% alcohol at room temperature. The films of PANI are deposited from solution by drop-casting on Ag electrodes, which are preliminary deposited on glass substrates. The thicknesses of the PANI films are in the range of 20 μm–80 μm. A displacement sensor with polyaniline film as an active material is designed and fabricated. The investigations showed that, on average, the AC resistance of the sensor decreases by 2 times and the capacitance accordingly increases by 1.6 times as the displacement changes in the range of 0 mm–0.5 mm. The polyaniline is the only active material of the displacement sensor. The resistance and capacitance of the PANI changes under the pressure of spring and elastic rubber, and this pressure is created by the downward movement of the micrometer. (general)

  7. A radiation-sensitive monomer of 2,4-hexadiyn-1,6-bis(p-toluene sulphonyl urethane) in PVA as a radiochromic film dosimeter

    Science.gov (United States)

    Soliman, Yasser S.; Abdel-Fattah, A. A.; Hamed, A. A.; Bayomi, A. M. M.

    2018-03-01

    A conjugated monomer 2,4-hexadiyn-1,6-bis(p-toluene sulphonyl urethane) (HDTU) was synthesized. Thereafter, it was incorporated into polyvinyl alcohol (PVA), and coated on self-adhesive sheet, thus to prepare film dosimeters. The monomer and films were analyzed using X-ray diffraction (XRD), FTIR spectroscopy and specular reflectance colorimetry. This monomer polymerizes in the films by radiation and turns progressively blue in proportion to absorbed dose, indicating the formation of π-conjugated colored poly-HDTU. Color development was investigated at 480 nm and 610 nm for dose monitoring ranging from 10 Gy to 15 kGy. HDTU in PVA film is highly ordered and crystalline and, upon irradiation, it forms a semi-crystalline polymer with nearly the same interplanar distances as the monomer, indicating the occurrence of topochemical polymerization. During irradiation, polymerization of the monomer is nearly independent of humidity in the range of 0-53% and temperature in the range of 25-45 °C. The uncertainty of this system is 5.16% at 95% confidence level.

  8. High performance hard magnetic NdFeB thick films for integration into micro-electro-mechanical systems

    International Nuclear Information System (INIS)

    Dempsey, N. M.; Walther, A.; May, F.; Givord, D.; Khlopkov, K.; Gutfleisch, O.

    2007-01-01

    5 μm thick NdFeB films have been sputtered onto 100 mm Si substrates using high rate sputtering (18 μm/h). Films were deposited at ≤500 deg. C and then annealed at 750 deg. C for 10 min. While films deposited at temperatures up to 450 deg. C have equiaxed grains, the size of which decreases with increasing deposition temperature, the films deposited at 500 deg. C have columnar grains. The out-of-plane remanent magnetization increases with deposition temperature, reaching a maximum value of 1.4 T, while the coercivity remains constant at about 1.6 T. The maximum energy product achieved (400 kJ/m 3 ) is comparable to that of high-quality NdFeB sintered magnets

  9. Clinical comparison between 100 mm photofluorography and digital (1024/sup 2/) fluoroscopic image acquisition

    International Nuclear Information System (INIS)

    Hynes, D.M.; Edmonds, E.W.; Rowlands, J.A.; Porter, A.J.; Toth, B.D.

    1986-01-01

    The authors describe current work in progress in which a clinical image can be recorded on both 100-mm film and a 1,024/sup 2/ image store with the same exposure. The 100-mm film is exposed in the usual manner. However, the same radiation exposure is utilized by the optics of the beam splitter to transfer the output image of the intensifier into a 1,024/sup 2/ image store and thence to hard copy by multiformat camera or laser printer. Comparative phantom and clinical images will be presented, along with observations on dose rates needed for diagnostic digital imaging. Use of this system may allow fluoroscopic dose rates to be reduced

  10. Fatigue characteristics of polycrystalline silicon thin-film membrane and its dependence on humidity

    International Nuclear Information System (INIS)

    Tanemura, Tomoki; Yamashita, Shuichi; Wado, Hiroyuki; Takeuchi, Yukihiro; Tsuchiya, Toshiyuki; Tabata, Osamu

    2013-01-01

    This paper describes fatigue characteristics of a polycrystalline silicon thin-film membrane under different humidity evaluated by out-of-plane resonant vibration. The membrane, without the surface of sidewalls by patterning of photolithography and etching process, was applied to evaluate fatigue characteristics precisely against the changes in the surrounding humidity owing to narrower deviation in the fatigue lifetime. The membrane has 16 mm square-shaped multilayered films consisting of a 250 or 500 nm thick polysilicon film on silicon dioxide and silicon nitride underlying layers. A circular weight of 12 mm in diameter was placed at the center of the membrane to control the resonant frequency. Stress on the polysilicon film was generated by deforming the membrane oscillating the weight in the out-of-plane direction. The polysilicon film was fractured by fatigue damage accumulation under cyclic stress. The lifetime of the polysilicon membrane extended with lower relative humidity, especially at 5%RH. The results of the fatigue tests were well formulated with Weibull's statistics and Paris’ law. The dependence of fatigue characteristics on humidity has been quantitatively revealed for the first time. The crack growth rate indicated by the fatigue index decreased with the reduction in humidity, whereas the deviation of strength represented by the Weibull modulus was nearly constant against humidity. (paper)

  11. Goldmann tonometry tear film error and partial correction with a shaped applanation surface.

    Science.gov (United States)

    McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M

    2018-01-01

    The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.

  12. High Ms Fe16N2 thin film with Ag under layer on GaAs substrate

    Energy Technology Data Exchange (ETDEWEB)

    Allard Jr, Lawrence Frederick [ORNL

    2016-01-01

    (001) textured Fe16N2 thin film with Ag under layer is successfully grown on GaAs substrate using a facing target sputtering (FTS) system. After post annealing, chemically ordered Fe16N2 phase is formed and detected by X-ray diffraction (XRD). High saturation magnetization (Ms) is measured by a vibrating sample magnetometer (VSM). In comparison with Fe16N2 with Ag under layer on MgO substrate and Fe16N2 with Fe under layer on GaAs substrate, the current layer structure shows a higher Ms value, with a magnetically softer feature in contrast to the above cases. In addition, X-ray photoelectron spectroscopy (XPS) is performed to characterize the binding energy of N atoms. To verify the role of strain that the FeN layer experiences in the above three structures, Grazing Incidence X-ray Diffraction (GIXRD) is conducted to reveal a large in-plane lattice constant due to the in-plane biaxial tensile strain. INTRODUCTION

  13. Spin-on Bi4Sr3Ca3Cu4O16μ/sub x/ superconducting thin films from citrate precursors

    International Nuclear Information System (INIS)

    Furcone, S.L.; Chiang, Y.

    1988-01-01

    Thin films in the Bi-Sr-Ca-Cu-O system have been synthesized from homogeneous liquid citrate precursors by a spin-coating and pyrolysis method. Films prepared on SrTiO 3 substrates of [100] orientation show strongly textured orientations with the c axis of the predominant Bi 4 Sr 3 Ca 3 Cu 4 O 16 μ/sub x/ phase normal to the film plane. In a single coating and firing, crack-free films of 0.2--0.5 μm thickness are obtained. For films fired to peak temperatures of 850--875 0 C, linearly decreasing resistance with temperature is observed, with rho (300 K)∼460 μΩ cm and rho (300 K)rho (100 K)∼2.4. Clear onsets of superconductivity are observed at 90--100 K, with occasional films showing smaller resistant drops at 110--120 K. For all films, T/sub c/ (R = 0) occurs in the range 70--75 K. High critical current densities at 4.2 K of 5--8 x 10 5 Acm 2 are measured by direct transport

  14. The Harvard Project Physics Film Program

    Science.gov (United States)

    Bork, Alfred M.

    1970-01-01

    States the philosophy behind the Harvard Project Physics (HPP) film program. Describes the three long HPP films. Lists the 48 color film loops covering six broad topics, primarily motion and energy. The 8-mm silent loops are synchronized with the text materials. Explains some of the pedagogical possibilities of these film loops. (RR)

  15. Structural properties 3,16-bis triisopropylsilylethynyl (pentacene) (TIPS-pentacene) thin films onto organic dielectric layer using slide coating method

    Energy Technology Data Exchange (ETDEWEB)

    Rusnan, Fara Naila; Mohamad, Khairul Anuar; Seria, Dzul Fahmi Mohd Husin; Saad, Ismail; Ghosh, Bablu K.; Alias, Afishah [Nano Engineering & Materials (NEMs) Research Group, Faculty of Engineering Universiti Malaysia Sabah, Kota Kinabalu 88400 Sabah (Malaysia)

    2015-08-28

    3,16-bis triisopropylsilylethynyl (Pentacene) (TIPS-Pentacene) compactable interface property is important in order to have a good arrangement of molecular structure. Comparison for TIPS-Pentacene deposited between two different surface layers conducted. 0.1wt% TIPS-Pentacene diluted in chloroform were deposited onto poly(methylmeaclyrate) (PMMA) layered transparent substrates using slide coating method. X-ray diffraction (XRD) used to determine crystallinity of thin films. Series of (00l) diffraction peaks obtained with sharp first peaks (001) for TIPS-Pentacene deposited onto PMMA layer at 5.35° and separation of 16.3 Å. Morphology and surface roughness were carried out using scanning electron microscope (SEM) and surface profilemeter LS500, respectively.TIPS-Pentacene deposited onto PMMA layer formed needled-like-shape grains with 10.26 nm surface roughness. These properties were related as thin film formed and its surface roughness plays important role towards good mobility devices.

  16. Influence of Bipolar Pulse Poling Technique for Piezoelectric Vibration Energy Harvesters using Pb(Zr,Ti)O3 Films on 200 mm SOI Wafers

    International Nuclear Information System (INIS)

    Moriwaki, N; Fujimoto, K; Suzuki, K; Kobayashi, T; Itoh, T; Maeda, R; Suzuki, Y; Makimoto, N

    2013-01-01

    Piezoelectric vibration energy harvester arrays using Pb(Zr,Ti)O 3 thin films on 200 mm SOI wafers were fabricated. In-plane distribution of influence of bipolar pulse poling technique on direct current (DC) power output from the harvesters was investigated. The results indicate that combination poling treatment of DC and bipolar pulse poling increases a piezoelectric property and reduces a dielectric constant. It means that this poling technique improves the figure of merit of sensors and harvesters. Maximum DC power from a harvester treated by DC poling after bipolar pulse poling is about five times larger than a one treated by DC poling only

  17. Buccal mucosa carcinoma: surgical margin less than 3 mm, not 5 mm, predicts locoregional recurrence

    Directory of Open Access Journals (Sweden)

    Chiou Wen-Yen

    2010-09-01

    Full Text Available Abstract Background Most treatment failure of buccal mucosal cancer post surgery is locoregional recurrence. We tried to figure out how close the surgical margin being unsafe and needed further adjuvant treatment. Methods Between August 2000 and June 2008, a total of 110 patients with buccal mucosa carcinoma (25 with stage I, 31 with stage II, 11 with stage III, and 43 with Stage IV classified according to the American Joint Committee on Cancer 6th edition were treated with surgery alone (n = 32, surgery plus postoperative radiotherapy (n = 38 or surgery plus adjuvant concurrent chemoradiotherapy (n = 40. Main outcome measures: The primary endpoint was locoregional disease control. Results The median follow-up time at analysis was 25 months (range, 4-104 months. The 3-year locoregional control rates were significantly different when a 3-mm surgical margin (≤3 versus >3 mm, 71% versus 95%, p = 0.04 but not a 5-mm margin (75% versus 92%, p = 0.22 was used as the cut-off level. We also found a quantitative correlation between surgical margin and locoregional failure (hazard ratio, 2.16; 95% confidence interval, 1.14 - 4.11; p = 0.019. Multivariate analysis identified pN classification and surgical margin as independent factors affecting disease-free survival and locoregional control. Conclusions Narrow surgical margin ≤3 mm, but not 5 mm, is associated with high risk for locoregional recurrence of buccal mucosa carcinoma. More aggressive treatment after surgery is suggested.

  18. Buccal mucosa carcinoma: surgical margin less than 3 mm, not 5 mm, predicts locoregional recurrence

    International Nuclear Information System (INIS)

    Chiou, Wen-Yen; Hung, Shih-Kai; Lin, Hon-Yi; Hsu, Feng-Chun; Lee, Moon-Sing; Ho, Hsu-Chueh; Su, Yu-Chieh; Lee, Ching-Chih; Hsieh, Chen-Hsi; Wang, Yao-Ching

    2010-01-01

    Most treatment failure of buccal mucosal cancer post surgery is locoregional recurrence. We tried to figure out how close the surgical margin being unsafe and needed further adjuvant treatment. Between August 2000 and June 2008, a total of 110 patients with buccal mucosa carcinoma (25 with stage I, 31 with stage II, 11 with stage III, and 43 with Stage IV classified according to the American Joint Committee on Cancer 6 th edition) were treated with surgery alone (n = 32), surgery plus postoperative radiotherapy (n = 38) or surgery plus adjuvant concurrent chemoradiotherapy (n = 40). Main outcome measures: The primary endpoint was locoregional disease control. The median follow-up time at analysis was 25 months (range, 4-104 months). The 3-year locoregional control rates were significantly different when a 3-mm surgical margin (≤3 versus >3 mm, 71% versus 95%, p = 0.04) but not a 5-mm margin (75% versus 92%, p = 0.22) was used as the cut-off level. We also found a quantitative correlation between surgical margin and locoregional failure (hazard ratio, 2.16; 95% confidence interval, 1.14 - 4.11; p = 0.019). Multivariate analysis identified pN classification and surgical margin as independent factors affecting disease-free survival and locoregional control. Narrow surgical margin ≤3 mm, but not 5 mm, is associated with high risk for locoregional recurrence of buccal mucosa carcinoma. More aggressive treatment after surgery is suggested

  19. Evaluation of gafchromic EBT film for intensity modulated radiation therapy dose distribution verification

    International Nuclear Information System (INIS)

    Sankar, A.; Gopalkrishna Kurup, P.G.; Murali, V.; Ayyangar, Komanduri M.; Mothilal Nehru, R.; Velmurugan, J.

    2006-01-01

    This work was undertaken with the intention of investigating the possibility of clinical use of commercially available self-developing radiochromic film - Gafchromic EBT film - for IMRT dose verification. The dose response curves were generated for the films using VXR-16 film scanner. The results obtained with EBT films were compared with the results of Kodak EDR2 films. It was found that the EBT film has a linear response between the dose ranges of 0 and 600 cGy. The dose-related characteristics of the EBT film, like post-irradiation color growth with time, film uniformity and effect of scanning orientation, were studied. There is up to 8.6% increase in the color density between 2 and 40 h after irradiation. There was a considerable variation, up to 8.5%, in the film uniformity over its sensitive region. The quantitative difference between calculated and measured dose distributions was analyzed using Gamma index with the tolerance of 3% dose difference and 3 mm distance agreement. EDR2 films showed good and consistent results with the calculated dose distribution, whereas the results obtained using EBT were inconsistent. The variation in the film uniformity limits the use of EBT film for conventional large field IMRT verification. For IMRT of smaller field size (4.5 x 4.5 cm), the results obtained with EBT were comparable with results of EDR2 films. (author)

  20. Sensitivity of screen-film systems

    International Nuclear Information System (INIS)

    Sandborg, M.; Nilsson, Goergen; Holje, G.

    1992-01-01

    This report, which has been funded by SSI, presents sensitivity data on the 'second generation' of modern intensifying screens, commercially available at the onset of the investigation. The sensitivity of the screen-film systems was evaluated with 80 kV tube potential and a total filtration of 3.0 mm Al. 20 mm aluminum was used for simulating human tissue, since it gives the same HVL x , as does 25 cm water. Kerma in air, needed to produce a net film density of 1.00 was determined and its inverse, expressed in mGy -1 , was taken as an indicator of the sensitivity; here called the sensitivity class of a screen-film system

  1. Influence of film dimensions on film droplet formation.

    Science.gov (United States)

    Holmgren, Helene; Ljungström, Evert

    2012-02-01

    Aerosol particles may be generated from rupturing liquid films through a droplet formation mechanism. The present work was undertaken with the aim to throw some light on the influence of film dimensions on droplet formation with possible consequences for exhaled breath aerosol formation. The film droplet formation process was mimicked by using a purpose-built device, where fluid films were spanned across holes of known diameters. As the films burst, droplets were formed and the number and size distributions of the resulting droplets were determined. No general relation could be found between hole diameter and the number of droplets generated per unit surface area of fluid film. Averaged over all film sizes, a higher surface tension yielded higher concentrations of droplets. Surface tension did not influence the resulting droplet diameter, but it was found that smaller films generated smaller droplets. This study shows that small fluid films generate droplets as efficiently as large films, and that droplets may well be generated from films with diameters below 1 mm. This has implications for the formation of film droplets from reopening of closed airways because human terminal bronchioles are of similar dimensions. Thus, the results provide support for the earlier proposed mechanism where reopening of closed airways is one origin of exhaled particles.

  2. A Comparison of Radiographic Film Densitometry Using a New Computerized Tool with a Digital Densitometer

    Directory of Open Access Journals (Sweden)

    Hoorieh Bashizadeh Fakhar

    2016-11-01

    Full Text Available Objectives: The purpose of this study was to develop and test a new tool for radiographic densitometry by combining periapical films and aluminum step wedge.Materials and Methods: We reviewed 50 Kodak E-speed intraoral films. An aluminum step wedge consisting of 16 steps was constructed. Each step was 1mmx3mx10mm. The step wedge was exposed to varying exposure times, ranging from 0.05 second to 0.5 second, increasing in 0.05 second increments. Films were digitalized after processing and the MATLAB software algorithm was ran subsequently. Density of the films was measured again using a digital densitometer. In order to compare the two imaging techniques, three steps were selected. Output data from the MATLAB algorithm were compared with data obtained from the digital densitometer.Results: The new method could detect significant differences between subsequent exposure times in step 7, while the densitometer did that in steps 7 and 12. The new method’s sensitivity in determining density changes was 5.26%, 84.1% and 93.02% in steps 2, 7, and 12 respectively.Conclusions: Our new method has an acceptable sensitivity for determining density changes of at least 7 mmEq/Al.Keywords: Densitometry; Image Processing, Computer-Assisted; Aluminum; Phantoms, Imaging

  3. Goldmann tonometry tear film error and partial correction with a shaped applanation surface

    Directory of Open Access Journals (Sweden)

    McCafferty SJ

    2018-01-01

    Full Text Available Sean J McCafferty,1–4 Eniko T Enikov,5 Jim Schwiegerling,2,3 Sean M Ashley1,3 1Intuor Technologies, 2Department of Ophthalmology, University of Arizona College of Medicine, 3University of Arizona College of Optical Science, 4Arizona Eye Consultants, 5Department of Mechanical and Aerospace, University of Arizona College of Engineering, Tucson, AZ, USA Purpose: The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT prism and in a correcting applanation tonometry surface (CATS prism.Methods: The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms.Results: The CATS prism tear film adhesion error (2.74±0.21 mmHg was significantly less than the GAT prism (4.57±0.18 mmHg, p<0.001. Tear film adhesion error was independent of applanation mire thickness (R2=0.09, p=0.04. Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p<0.001. Cadaver eye validation indicated the CATS prism’s tear film adhesion error (1.40±0.51 mmHg was significantly less than that of the GAT prism (3.30±0.38 mmHg; p=0.002.Conclusion: Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error by ~41%. Fluorescein solution increases the tear film adhesion compared to

  4. Ti-O/TiN films synthesized by plasma immersion ion implantation and deposition on 316L: Study of deformation behavior and mechanical properties

    International Nuclear Information System (INIS)

    Wan, G.J.; Huang, N.; Yang, P.; Leng, Y.X.; Sun, H.; Chen, J.Y.; Wang, J.

    2005-01-01

    Ti-O/TiN gradient films have been synthesized on 316L stainless steel using plasma immersion ion implantation and deposition (PIII and D). The coated samples were subjected to tensile testing and observed in situ by scanning electron microscopy. No delamination, peeling or cracking was found on the film after plastic deformation of 0.16 mm residual displacement. Nanoindentation and nanoscratch tests revealed that the prepared films possess high nanohardness and good adhesion strength to the metal substrate. The mechanical properties of the synthesized Ti-O/TiN films are thought to be attributed to the good nanostructure, high density, smooth surface, slow transition from Ti-O to TiN and broad film/matrix interface achieved by the PIII-D process

  5. Rapid fabrication of transparent conductive films with controllable sheet resistance on glass substrates by laser annealing of diamond-like carbon films

    International Nuclear Information System (INIS)

    Lee, Keunhee; Ki, Hyungson

    2016-01-01

    We report a laser-based method for directly fabricating large-area, transparent conductive films with customizable electrical resistance on glass. In this method, a diamond-like carbon (DLC) film is deposited first on a glass substrate by pulsed laser deposition, which is then annealed in a helium shielding environment by a 2 kW continuous-wave fiber laser with a wavelength of 1070 nm, which is transparent to glass but is absorbed by DLC to transform the amorphous carbons to graphene. When a 510 nm thick film was annealed at a scanning speed of 1 m/s by a 200 μm top-hat laser beam, the sp 3 fraction was decreased from 43.1% to 8.1% after the annealing process, and the transformed film showed a transparency of ∼80% (at 550 nm) and a sheet resistance of ∼2050 Ω/sq. We also showed that sheet resistance and transparency can be controlled by changing processing parameters. To show the scalability of the method, a 15 mm wide line beam was used to produce a 15 mm × 15 mm film. This method is simple, fully scalable, transfer-free and catalyst-free, and we believe that the fabricated films can have many applications with further research, such as transparent heating films, electromagnetic shielding films, and transparent electrodes.

  6. Mueller matrix spectroscopic ellipsometry study of chiral nanocrystalline cellulose films

    Science.gov (United States)

    Mendoza-Galván, Arturo; Muñoz-Pineda, Eloy; Ribeiro, Sidney J. L.; Santos, Moliria V.; Järrendahl, Kenneth; Arwin, Hans

    2018-02-01

    Chiral nanocrystalline cellulose (NCC) free-standing films were prepared through slow evaporation of aqueous suspensions of cellulose nanocrystals in a nematic chiral liquid crystal phase. Mueller matrix (MM) spectroscopic ellipsometry is used to study the polarization and depolarization properties of the chiral films. In the reflection mode, the MM is similar to the matrices reported for the cuticle of some beetles reflecting near circular left-handed polarized light in the visible range. The polarization properties of light transmitted at normal incidence for different polarization states of incident light are discussed. By using a differential decomposition of the MM, the structural circular birefringence and dichroism of a NCC chiral film are evaluated.

  7. The Preparation of Graphene Reinforced Poly(vinyl alcohol Antibacterial Nanocomposite Thin Film

    Directory of Open Access Journals (Sweden)

    Yuan-Cheng Cao

    2015-01-01

    Full Text Available Methylated melamine grafted polyvinyl benzylchloride (mm-g-PvBCl was prepared which was used as additive in poly(vinyl alcohol (PVA and graphene nanosheets (GNs were used to reinforce the mechanical strength. Using casting method, antimicrobial nanocomposite films were prepared with the polymeric biocide loading lever of 1 wt%, 5 wt%, and 10 wt%. Thermogravimetric analysis (TGA characterization revealed the 2.0 wt% of graphene content in resultant nanocomposites films. XRD showed that the resultant GNs 2 theta was changed from 16.6 degree to 23.3 degree. Using Japanese Industry Standard test methods, the antimicrobial efficiency for the loading lever of 1 wt%, 5 wt%, and 10 wt% was 92.0%, 95.8%, and 97.1%, respectively, against gram negative bacteria E. coli and 92.3%, 99.6%, and 99.7%, respectively, against the gram positive S. aureus. These results indicate the prepared nanocomposite films are the promising materials for the food and drink package applications.

  8. Physical-mechanical and electrical properties of aluminium anodic films

    Energy Technology Data Exchange (ETDEWEB)

    Dima, L. [Research and Design Inst. for Electr. Eng., Bucharest (Romania); Anicai, L. [Research and Design Inst. for Electr. Eng., Bucharest (Romania)

    1995-11-01

    Mechanical, thermal and electrical properties of aluminium anodic films obtained by continuously anodization of Al wires of 4.5 mm diameter and Al sheets of 40 x 0.2 mm (Al min.99.5% purity), using an electrolyte based on oxalic acid, citric acid, boric acid, isopropilic alcohol, were investigated. The thickness of Al anodic oxide layers was 5 {+-} 1{mu}, 10 {+-} 1{mu}, for Al sheet, respectively 5 {+-} 1{mu}, 10 {+-} 1{mu}, 15 {+-} 1{mu}, for Al wire. To establish the influence of anodic film formation on mechanical parameters, measurements of breaking strength and relative elongation at break for anodized and non-anodized Al conductors, were made. In order to electrically characterize the anodic films, the breakdown voltage for different curvature radii of the conductor, between 50 - 12.5 mm, were measured. The influence of the layer thickness, as well as of the cracking during its bending, was established, too. To test the thermal resistance of the insulating anodic films, the Al conductors were subjected to 1 - 5 cyclic thermal shocks at 500 C. After the experimentals were done, it was found that Al anodic films of 5 {+-} 1{mu} may assure a breakdown voltage of minimum 200 V, for coils having a curvature radius greater than 12.5 mm and operating temperatures up to 500 C. From mechanical point of view, anodic oxide film determines a relatively reinforcing of Al conductor, but it doesn`t influence its functional properties. (orig.)

  9. Large-area SnO2: F thin films by offline APCVD

    International Nuclear Information System (INIS)

    Wang, Yan; Wu, Yucheng; Qin, Yongqiang; Zhang, Zhihai; Shi, Chengwu; Zhang, Qingfeng; Li, Changhao; Xia, Xiaohong; Sun, Stanley; Chen, Leon

    2011-01-01

    Highlights: → Large-area (1245 mm x 635 mm) FTO thin films were successfully deposited by offline APCVD process. → The as-prepared FTO thin films with sheet resistance 8-11 Ω/□ and direct transmittance more than 83% exhibited better than that of the online ones. → The maximum quantum efficiency of the solar cells based on offline FTO substrate was 0.750 at wavelength 540 nm. → The power of the solar modules using the offline FTO as glass substrates was 51.639 W, higher than that of the modules based on the online ones. -- Abstract: In this paper, we reported the successful preparation of fluorine-doped tin oxide (FTO) thin films on large-area glass substrates (1245 mm x 635 mm x 3 mm) by self-designed offline atmospheric pressure chemical vapor deposition (APCVD) process. The FTO thin films were achieved through a combinatorial chemistry approach using tin tetrachloride, water and oxygen as precursors and Freon (F-152, C2H4F2) as dopant. The deposited films were characterized for crystallinity, morphology (roughness) and sheet resistance to aid optimization of materials suitable for solar cells. We got the FTO thin films with sheet resistance 8-11 Ω/□ and direct transmittance more than 83%. X-ray diffraction (XRD) characterization suggested that the as-prepared FTO films were composed of multicrystal, with the average crystal size 200-300 nm and good crystallinity. Further more, the field emission scanning electron microscope (FESEM) images showed that the films were produced with good surface morphology (haze). Selected samples were used for manufacturing tandem amorphous silicon (a-Si:H) thin film solar cells and modules by plasma enhanced chemical vapor deposition (PECVD). Compared with commercially available FTO thin films coated by online chemical vapor deposition, our FTO coatings show excellent performance resulting in a high quantum efficiency yield for a-Si:H solar cells and ideal open voltage and short circuit current for a-Si:H solar

  10. Angiographic examinations with the medium size technique (70 mm films)

    International Nuclear Information System (INIS)

    Heuck, F.; Reichardt, W.

    1981-01-01

    The applicability of medium-size technique was tested in angiographic examinations of thoracic and abdominal organs. By means of full-size image intensifiers it is possible to carry out organ angiography, and by means of a pace control mechanism for the patient transport, the angiography of the extremities can be realized. Examples are given illustrate the informational value in cases where the arial and venous vascular systems of organs and extremities are concerned. The particular advantages for functional analyses of organ circulatory systems in cases of angiography are described. Two factors of importance are pointed out: the reduction of the exposure to irradiation for the patient on the one hand, and the increasing film prices on the other hand. The authors demand to overcome the psychological problems arising in the medical working groups where the medium-size technique shall be introduced into routine diagnostics. (orig./APR) [de

  11. Karakteristik Edible Film dari Pati Kentang (Solanum Tuberosum L. dengan Penambahan Gliserol

    Directory of Open Access Journals (Sweden)

    Sjamsiah Sjamsiah

    2017-12-01

    Full Text Available Edible film is a thin layer that serve as the packaging or upholstery as well as food that can be eaten with a product. It is packaged and can be degraded by nature. Potato starch can be used as raw material in manufacturing edible film, in which the addition of glycerol is needed as a plasticizer that function to improve the elasticity of the edible film. The goal of the research is to know the influence of glycerol concentration variation against the characteristics of edible film of starch potatoes (Solanum tuberosum L. the parameters examined in this study i.e the physical test that includes a test of strong thickness, tensile test and present enlargement, test the solubility and organoleptic. To help figure out the data obtained in the real effect or not, is done using the SPSS Analysis Variant 1 direction or one-way ANOVA. Characteristics of edible film from potato starch with addition of glycerol with a concentration of 20%, 30% and 40% (v/v to the value of the thickness of consecutive 0,058 mm, 0,062 mm and 0,071mm. The value of the tensile strengh i.e 0,75 N/mm2, 0,69 N/mm2 and 0,35 N/mm2. The value obtained by elongation percent 4,96%, 9,04% and 9,51% where as the value of solubility is obtained that is 19%, 21,4% and 34,6%. Application of edible films from potato starch as the packaging on candy jelly can be acceptedas alternative packaging material for food.

  12. High-contrast resolution of film-screen systems in oral and maxillofacial radiology

    International Nuclear Information System (INIS)

    Kaeppler, G.; Reinert, S.

    2007-01-01

    Purpose: The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same X-ray units as those used for patient radiographs. Materials and methods: The MTF was determined using a lead grid and according to DIN 6867 - 2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. Results: With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). (orig.)

  13. Resting RSA Is Associated with Natural and Self-Regulated Responses to Negative Emotional Stimuli

    Science.gov (United States)

    Demaree, Heath A.; Robinson, Jennifer L.; Everhart, D. Erik; Schmeichel, Brandon J.

    2004-01-01

    Resting respiratory sinus arrhythmia (RSA) was assessed among 111 adult participants. These individuals were then asked to watch a positive or negative affective film in either a natural manner or while exaggerating their facial response. Facial reactions to the film were video-recorded and subsequently rated in terms of facial affect.…

  14. Roll-to-roll slot-die coating of 400 mm wide, flexible, transparent Ag nanowire films for flexible touch screen panels.

    Science.gov (United States)

    Kim, Dong-Ju; Shin, Hae-In; Ko, Eun-Hye; Kim, Ki-Hyun; Kim, Tae-Woong; Kim, Han-Ki

    2016-09-28

    We report fabrication of large area Ag nanowire (NW) film coated using a continuous roll-to-roll (RTR) slot die coater as a viable alternative to conventional ITO electrodes for cost-effective and large-area flexible touch screen panels (TSPs). By controlling the flow rate of shear-thinning Ag NW ink in the slot die, we fabricated Ag NW percolating network films with different sheet resistances (30-70 Ohm/square), optical transmittance values (89-90%), and haze (0.5-1%) percentages. Outer/inner bending, twisting, and rolling tests as well as dynamic fatigue tests demonstrated that the mechanical flexibility of the slot-die coated Ag NW films was superior to that of conventional ITO films. Using diamond-shape patterned Ag NW layer electrodes (50 Ohm/square, 90% optical transmittance), we fabricated 12-inch flexible film-film type and rigid glass-film-film type TSPs. Successful operation of flexible TSPs with Ag NW electrodes indicates that slot-die-coated large-area Ag NW films are promising low cost, high performance, and flexible transparent electrodes for cost-effective large-area flexible TSPs and can be substituted for ITO films, which have high sheet resistance and are brittle.

  15. Roll-to-roll slot-die coating of 400 mm wide, flexible, transparent Ag nanowire films for flexible touch screen panels

    Science.gov (United States)

    Kim, Dong-Ju; Shin, Hae-In; Ko, Eun-Hye; Kim, Ki-Hyun; Kim, Tae-Woong; Kim, Han-Ki

    2016-09-01

    We report fabrication of large area Ag nanowire (NW) film coated using a continuous roll-to-roll (RTR) slot die coater as a viable alternative to conventional ITO electrodes for cost-effective and large-area flexible touch screen panels (TSPs). By controlling the flow rate of shear-thinning Ag NW ink in the slot die, we fabricated Ag NW percolating network films with different sheet resistances (30-70 Ohm/square), optical transmittance values (89-90%), and haze (0.5-1%) percentages. Outer/inner bending, twisting, and rolling tests as well as dynamic fatigue tests demonstrated that the mechanical flexibility of the slot-die coated Ag NW films was superior to that of conventional ITO films. Using diamond-shape patterned Ag NW layer electrodes (50 Ohm/square, 90% optical transmittance), we fabricated 12-inch flexible film-film type and rigid glass-film-film type TSPs. Successful operation of flexible TSPs with Ag NW electrodes indicates that slot-die-coated large-area Ag NW films are promising low cost, high performance, and flexible transparent electrodes for cost-effective large-area flexible TSPs and can be substituted for ITO films, which have high sheet resistance and are brittle.

  16. Low-frequency Wiener spectra for homogenity analysis of image-forming films at imaging with film-foils systems in radiography

    International Nuclear Information System (INIS)

    Wolf, M.; Angerstein, W.

    1986-01-01

    A special photometer for the measurement of image Wiener spectra below spatial frequencies of 1 mm -1 is described. These low-frequency Wiener spectra allow a quantitative assessment of inhomogeneities of screens and films (such as clouds and coarse structures) introduced in the production process. Noise with frequencies below the usually measured frequency range of 1 to 7 mm -1 is decisive for the detection of the diagnostically important details greater than 1 mm. It appears, that the noise amplitudes and their differences between screens of the same type can be relatively high. This in accordance with the visual noise impression indicates, that low frequency noise is an important image quality factor for screen-film systems. (author)

  17. Ferroelectric Thin Films III, Symposium Held in San Francisco, California on April 13 - 16, 1993. Materials Research Society Symposium Proceedings, Volume 310

    Science.gov (United States)

    1993-04-16

    Publication Data Ferroelectric thin films III : symposium held April 13-16, 1993, San Francisco,California, U.S.A. / editors, Bruce A. Turtle , Edwlrd R...All solutions were placed in a modified Collison Nebulizer which generated the droplets in an oxygen carrier gas. The droplets were transported into

  18. FOREIGN LANGUAGE FILMS IN LOUISIANA DEPOSITORIES.

    Science.gov (United States)

    BABINEAUX, AUDREY

    THIS MANUAL IS AN ANNOTATED LIST OF 16-MILLIMETER EDUCATIONAL FOREIGN LANGUAGE FILMS (BOTH LINGUISTIC AND CULTURAL) WHICH WERE PURCHASED WITH STATE AND FEDERAL FUNDS AND PLACED IN LOUISIANA'S NINE FILM LIBRARIES. FILMS ARE ARRANGED ALPHABETICALLY BY LANGUAGES. FILMS IN THE TARGET LANGUAGE ARE LISTED SEPARATELY FROM FILMS WITH ENGLISH NARRATION. A…

  19. Sample Set (SE): SE16 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available SE16 Effect of agricultural films for spinach leaf metabolites 2 Investigation of S...pinacia oleracea leaf metabolites. 3 growth conditions (covered with normal or UV cut agricultural film or no agricultura

  20. Plasticizing Effects of Polyamines in Protein-Based Films

    Directory of Open Access Journals (Sweden)

    Mohammed Sabbah

    2017-05-01

    Full Text Available Zeta potential and nanoparticle size were determined on film forming solutions of native and heat-denatured proteins of bitter vetch as a function of pH and of different concentrations of the polyamines spermidine and spermine, both in the absence and presence of the plasticizer glycerol. Our results showed that both polyamines decreased the negative zeta potential of all samples under pH 8.0 as a consequence of their ionic interaction with proteins. At the same time, they enhanced the dimension of nanoparticles under pH 8.0 as a result of macromolecular aggregations. By using native protein solutions, handleable films were obtained only from samples containing either a minimum of 33 mM glycerol or 4 mM spermidine, or both compounds together at lower glycerol concentrations. However, 2 mM spermidine was sufficient to obtain handleable film by using heat-treated samples without glycerol. Conversely, brittle materials were obtained by spermine alone, thus indicating that only spermidine was able to act as an ionic plasticizer. Lastly, both polyamines, mainly spermine, were found able to act as “glycerol-like” plasticizers at concentrations higher than 5 mM under experimental conditions at which their amino groups are undissociated. Our findings open new perspectives in obtaining protein-based films by using aliphatic polycations as components.

  1. Wear resistant PTFE thin film enabled by a polydopamine adhesive layer

    International Nuclear Information System (INIS)

    Beckford, Samuel; Zou, Min

    2014-01-01

    The influence of a polydopamine (PDA) adhesive layer on the friction and wear resistance of polytetrafluoroethylene (PTFE) thin films coated on stainless steel was investigated. The friction and wear tests were carried out using a ball on flat configuration under a normal load of 50 g, sliding speed of 2.5 mm/s, and stroke length of 15 mm. It is found that the PDA/PTFE film is able to withstand approximately 500 times more rubbing cycles than the PTFE film alone. X-ray photoelectron spectroscopy (XPS) results show that a tenacious layer of PTFE remains adhered to the PDA layer, which enables the durability of the PDA/PTFE film. Because of the relatively low thickness of the film, PDA/PTFE shows great potential for use in applications where durable, thin films are desirable

  2. Flushing-free film test of "1"9"2Ir accuracy of position and step distance for afterloading systems

    International Nuclear Information System (INIS)

    Lu Feng; Chen Rui; Shang Yunying; Chen Yue; Min Nan; Chen Yingmin; Deng Daping

    2014-01-01

    Objective: To study the method of measuring the position accuracy and the step distance accuracy of afterloading system with "1"9"2Ir source by using flushing-free film. Methods: The position accuracy and the step distance accuracy of a China-made afterloading system with "1"9"2Ir source was measured by using GAFCHROMIC"® EBT"3 flushing-free film. The film was scanned to proper image format, required by dose analysis software, by EPSON PREFACTION V700 PHOTO scanner. Then images are analyzed by using film dose analysis software in SNC Patient 5.2. Results: With focus on the center of active section of source, the position accuracy of this afterloading system with "1"9"2Ir source was -0.75 mm. Using film analysis could make the step point to tell apart if the step distance was 5 mm away by the method of film analysis, but couldnot make it to tell apart if the step distance was 2.5 mm away. The 2.5 mm step distance accuracy could be judged if the distance between the 1"s"t point and the 3"r"d point was 5 mm, then the 2.5 mm step distance could be deemed to no deviation. The 5 mm step distance of this afterloading system had no deviation in continuous 9 step points measured by flushing-free film. The indirect measuring results of the 2.5 mm step distance had no deviation as well. The position accuracy of this afterloading system measured with the flushing-free film accorded with the national standards. Conclusions: The method of measuring the position accuracy and the step distance accuracy of the afterloading system with "1"9"2Ir source by using flushing-free film is technically feasible. (authors)

  3. Investigation of size effect on film type haptic actuator made with cellulose acetate

    International Nuclear Information System (INIS)

    Kim, Sang-Youn; Kim, Jaehwan; Kim, Ki-Baek

    2014-01-01

    The most important factor in haptic interaction with hand-held devices is to develop a thin film type actuator which can be easily inserted into the devices and create vibrotactile signals with wide frequency bandwidth. This paper reports a film type vibrotactile actuator which is tiny enough to be embedded into small hand-held devices. The vibration mechanism and experiment results for the suggested vibrotactile actuator are explained. The aim of the actuator is to convey a vibrotactile force greater than a human’s vibrotactile threshold with broad frequency bandwidth to users. To achieve the requirement, we fabricate a film type vibrotactile actuator with cellulose acetate. When an AC voltage is applied to the actuator, the cellulose acetate film gets charged and then generates vibration. The suggested vibrotactile actuator is fabricated in two sizes: 50 mm × 25 mm and 25 mm × 25 mm. For each size of actuator, three kinds of actuator are fabricated with different pillar materials to support the cellulose acetate films. An experiment for measuring vibrational amplitude is conducted over a wide frequency range of actuation voltage. It is known that the proposed film type actuator is feasible for haptic application in the small hand-held devices. (paper)

  4. Computed tomography of active pulmonary tuberculosis with nonvisualized cavitary lesion on plain chest film

    International Nuclear Information System (INIS)

    Ahn, Woo Hyun; Cho, Seoung Hwan; Lee, Jun Bae; Kim, Byung Soo

    1989-01-01

    The detection of cavity in pulmonary tuberculosis has important roles in its diagnosis, therapy planning and follow-up of healing process, and also means at least moderate advanced tuberculosis. The plain chest film has some limitation of detection of cavity in pulmonary tuberculosis owing to several factors. CT is superior to plain chest film and conventional tomography, in detection of cavitary lesion. Authors retrospectively analyzed CT findings of 20 cases of minimal pulmonary tuberculosis, of which the plain chest films showed no cavitary lesion from Sept. 1986 to July 1988 in Pusan National University Hospital. All cases were proven by culture or AFB test of sputum and clinical evidence. The results were as follows: 1. Sex distribution showed 10 cases (50%) in male, 10 case (50%) in female and the highest incidence in the second decade (40%). 2. All 20 cases showed no cavity on the plain chest films, but all cases showed variable sized cavities on CT. 3. The size of cavities ranged from 4 mm to 30 mm, averaged as 9.9 mm, the thickness of cavitary wall from 3 mm to 8 mm, averaged as 5.8 mm. 4. It is concluded that cavitary lesions which are not visualized on the plain chest films can be demonstrated by CT scan in minimal pulmonary tuberculosis

  5. New depositing method of Langmuir-Blodgett film of fatty acid soap as a radioactive source

    Energy Technology Data Exchange (ETDEWEB)

    Iwahashi, Makio; Watanabe, Norifumi; Seimiya, Tsutomu; Naito, Fujio

    1985-02-01

    A stable radioactive source in vacuo was obtained by a new depositing method of Langmuir-Blodgett (L/B) film. In spite of the slight consumption of the substrate solution (only 2-2.5 ml) for preparing a 15 mm x 25 mm sized L/B film containing four molecular layers of /sup 109/Cd-eicosanoate, the deposition of the film was complete. (author).

  6. Measurement of high energy x-ray beam penumbra with Gafchromic trade mark sign EBT radiochromic film

    International Nuclear Information System (INIS)

    Cheung Tsang; Butson, Martin J.; Yu, Peter K. N.

    2006-01-01

    High energy x-ray beam penumbra are measured using Gafchromic trade mark sign EBT film. Gafchromic trade mark sign EBT, due to its limited energy dependence and high spatial resolution provide a high level of accuracy for dose assessment in penumbral regions. The spatial resolution of film detector systems is normally limited by the scanning resolution of the densitometer. Penumbral widths (80%/20%) measured at D max were found to be 2.8, 3.0, 3.2, and 3.4 mm (±0.2 mm) using 5, 10, 20, and 30 cm square field sizes, respectively, for a 6 MV linear accelerator produced x-ray beam. This is compared to 3.2 mm±0.2 mm (Kodak EDR2) and 3.6 mm±0.2 mm (Kodak X-Omat V) at 10 cmx10 cm measured using radiographic film. Using a zero volume extrapolation technique for ionization chamber measurements, the 10 cmx10 cm field penumbra at D max was measured to be 3.1 mm, a close match to Gafchromic trade mark sign EBT results. Penumbral measurements can also be made at other depths, including the surface, as the film does not suffer significantly from dosimetric variations caused by changing x-ray energy spectra. Gafchromic trade mark sign EBT film provides an adequate measure of penumbral dose for high energy x-ray beams

  7. The Herschel Multi-Tiered Extragalactic Survey: SPIRE-mm Photometric Redshifts

    Science.gov (United States)

    Roseboom, I. G.; Ivison, R. J.; Greve, T. R.; Amblard, A.; Arumugam, V.; Auld, R.; Aussel, H.; Bethermin, M.; Blain, A.; Bock, J.; hide

    2011-01-01

    We investigate the potential of submm-mm and submm-mm-radio photometric red-shifts using a sample of mm-selected sources as seen at 250, 350 and 500 micrometers by the SPIRE instrument on Herschel. From a sample of 63 previously identified mm-sources with reliable radio identifications in the GOODS-N and Lockman Hole North fields 46 (73 per cent) are found to have detections in at least one SPIRE band. We explore the observed submm/mm colour evolution with redshift, finding that the colours of mm-sources are adequately described by a modified blackbody with constant optical depth Tau = (nu/nu(0))beta where beta = +1.8 and nu(0) = c/100 micrometers. We find a tight correlation between dust temperature and IR luminosity. Using a single model of the dust temperature and IR luminosity relation we derive photometric redshift estimates for the 46 SPIRE detected mm-sources. Testing against the 22 sources with known spectroscopic, or good quality optical/near-IR photometric, redshifts we find submm/mm photometric redshifts offer a redshift accuracy of |delta z|/(1+z) = 0.16 (less than |delta z| greater than = 0.51). Including constraints from the radio-far IR correlation the accuracy is improved to |delta z|/(1 + z) = 0.15 (less than |delta z| greater than = 0.45). We estimate the redshift distribution of mm-selected sources finding a significant excess at z greater than 3 when compared to 850 micrometer selected samples.

  8. Track chambers based on precision drift tubes housed inside 30 mm mylar pipe

    International Nuclear Information System (INIS)

    Borisov, A; Bozhko, N; Fakhrutdinov, R; Kozhin, A; Leontiev, B; Levin, A

    2014-01-01

    We describe drift chambers consisting of 3 layers of 30 mm (OD) drift tubes made of double sided aluminized mylar film with thickness 0.125 mm. A single drift tube is self-supported structure withstanding 350 g tension of 50 microns sense wire located in the tube center with 10 microns precision with respect to end-plug outer surface. Such tubes allow to create drift chambers with small amount of material, construction of such chambers doesn't require hard frames. Twenty six chambers with working area from 0.8 × 1.0 to 2.5 × 2.0 m 2 including 4440 tubes have been manufactured for experiments at 70-GeV proton accelerator at IHEP(Protvino)

  9. Track chambers based on precision drift tubes housed inside 30 mm mylar pipe

    Science.gov (United States)

    Borisov, A.; Bozhko, N.; Fakhrutdinov, R.; Kozhin, A.; Leontiev, B.; Levin, A.

    2014-06-01

    We describe drift chambers consisting of 3 layers of 30 mm (OD) drift tubes made of double sided aluminized mylar film with thickness 0.125 mm. A single drift tube is self-supported structure withstanding 350 g tension of 50 microns sense wire located in the tube center with 10 microns precision with respect to end-plug outer surface. Such tubes allow to create drift chambers with small amount of material, construction of such chambers doesn't require hard frames. Twenty six chambers with working area from 0.8 × 1.0 to 2.5 × 2.0 m2 including 4440 tubes have been manufactured for experiments at 70-GeV proton accelerator at IHEP(Protvino).

  10. SU-E-T-71: A Radiochromic Film Based Quantitative Assessment of Thermoplastic Mask Bolus Effect in Head and Neck IMRT/VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Kalavagunta, C; Lin, M; Snider, J; Xu, H; Schrum, A; Vadnais, P; Marter, K; Suntharalingam, M; Prado, K [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between mask and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization.

  11. SU-E-T-71: A Radiochromic Film Based Quantitative Assessment of Thermoplastic Mask Bolus Effect in Head and Neck IMRT/VMAT

    International Nuclear Information System (INIS)

    Kalavagunta, C; Lin, M; Snider, J; Xu, H; Schrum, A; Vadnais, P; Marter, K; Suntharalingam, M; Prado, K

    2015-01-01

    Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between mask and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization

  12. Quality Imaging - Comparison of CR Mammography with Screen-Film Mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin Nieto, J.; Iran Diaz Gongora, J. A.; Arreola, M.; Casian Castellanos, G.; Perdigon Castaneda, G. M.; Franco Enriquez, J. G.

    2006-01-01

    The aim of this work is a quality imaging comparison of CR mammography images printed to film by a laser printer with screen-film mammography. A Giotto and Elscintec dedicated mammography units with fully automatic exposure and a nominal large focal spot size of 0.3 mm were used for the image acquisition of phantoms in screen-film mammography. Four CR mammography units from two different manufacturers and three dedicated x-ray mammography units with fully automatic exposure and a nominal large focal spot size of 0.3 mm were used for the image acquisition of phantoms in CR mammography. The tests quality image included an assessment of system resolution, scoring phantom images, Artifacts, mean optical density and density difference (contrast). In this study, screen-film mammography with a quality control program offers a significantly greater level of quality image relative to CR mammography images printed on film

  13. Film Boiling on Downward Quenching Hemisphere of Varying Sizes

    Energy Technology Data Exchange (ETDEWEB)

    Chan S. Kim; Kune Y. Suh; Joy L. Rempe; Fan-Bill Cheung; Sang B. Kim

    2004-04-01

    Film boiling heat transfer coefficients for a downward-facing hemispherical surface are measured from the quenching tests in DELTA (Downward-boiling Experimental Laminar Transition Apparatus). Two test sections are made of copper to maintain low Biot numbers. The outer diameters of the hemispheres are 120 mm and 294 mm, respectively. The thickness of all the test sections is 30 mm. The effect of diameter on film boiling heat transfer is quantified utilizing results obtained from the test sections. The measured data are compared with the numerical predictions from laminar film boiling analysis. The measured heat transfer coefficients are found to be greater than those predicted by the conventional laminar flow theory on account of the interfacial wavy motion incurred by the Helmholtz instability. Incorporation of the wavy motion model considerably improves the agreement between the experimental and numerical results in terms of heat transfer coefficient. In addition, the interfacial wavy motion and the quenching process are visualized through a digital camera.

  14. Spin injection from epitaxial Heusler alloy thin films into InGaAs/GaAs quantum wells

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad

    2006-01-01

    -stoichiometric crystals and crystals with site swapping defects. Significant decrease in the spin polarization has been predicted for disorder defects involving especially Co on Mn or Ga sites. From an estimate based on the calculated defect formation energies it is found that Mn on Co-sites are likely to exist...... no anisotropy is seen for near stoichiometry thin films on an ordinary GaAs surface. Typically thin films grown on GaAs show lower saturation magnetization than expected from bulk properties. The electrical characterizations have revealed resistivities around ρ = 350μΩcm at 300 K. Generally, the near...... to typically 0.02-0.1 Ωmm2 for Fe and Co contacts but two orders of magnitude higher for the Co2MnGa contacts. Point contact Andreev reflection measurements on an off-stoichiometric thin film (Co2.4Mn1.6Ga) show a spin polarization of P ≈ 50 %. Furthermore spin injection into a InGaAs/GaAs quantum well have...

  15. Characteristic and quality control test in sector collimator gamma knife perfexion at Siloam hospital

    Science.gov (United States)

    Wesly Manik, Jhon; Hidayanto, Eko; Sutanto, Heri

    2017-01-01

    In this study conducted to evaluate the collimator 4 mm, 8 mm, 16 mm to determine the level of precision Gamma Knife Perfexion there three years and eight months has not carried out measurements after the first year and verify the alignment of sector 1-8. Measurement with three axes (x-axis, y-axis, z-axis) using the film Gafcromic EBT-3, which will be signaled to a central point in the film to be measured and given a dose of 5 Gy for 10 minutes and then scanned and analyzed using ImageJ softwere 1.50 and dose rate in film comparison with measurent dose rate using electrometer. Alignment of Patient-Positioning System (PPS) with Radiation Focal Point (RFP) determination of quality control testing each collimator 4 mm in the standard test with 0.4 mm passive voice AAPM 54. The results of the standard are still in conformity item 0.21 mm for 4 mm and corelasi dose rate film and measurent using electrometer collimator 4 mm = 0.965, 8 mm = 0.964, 16 mm = 0.959.

  16. Characteristic and quality control test in sector collimator gamma knife perfexion at Siloam hospital

    International Nuclear Information System (INIS)

    Manik, Jhon Wesly; Hidayanto, Eko; Sutanto, Heri

    2017-01-01

    In this study conducted to evaluate the collimator 4 mm, 8 mm, 16 mm to determine the level of precision Gamma Knife Perfexion there three years and eight months has not carried out measurements after the first year and verify the alignment of sector 1-8. Measurement with three axes (x-axis, y-axis, z-axis) using the film Gafcromic EBT-3, which will be signaled to a central point in the film to be measured and given a dose of 5 Gy for 10 minutes and then scanned and analyzed using ImageJ softwere 1.50 and dose rate in film comparison with measurent dose rate using electrometer. Alignment of Patient-Positioning System (PPS) with Radiation Focal Point (RFP) determination of quality control testing each collimator 4 mm in the standard test with < 0.1 and > 0.4 mm passive voice AAPM 54. The results of the standard are still in conformity item 0.21 mm for 4 mm and corelasi dose rate film and measurent using electrometer collimator 4 mm = 0.965, 8 mm = 0.964, 16 mm = 0.959. (paper)

  17. Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification.

    Science.gov (United States)

    Sankar, A; Ayyangar, Komanduri M; Nehru, R Mothilal; Kurup, P G Gopalakrishna; Murali, V; Enke, Charles A; Velmurugan, J

    2006-01-01

    The quantitative dose validation of intensity-modulated radiation therapy (IMRT) plans require 2-dimensional (2D) high-resolution dosimetry systems with uniform response over its sensitive region. The present work deals with clinical use of commercially available self-developing Radio Chromic Film, Gafchromic EBT film, for IMRT dose verification. Dose response curves were generated for the films using a VXR-16 film scanner. The results obtained with EBT films were compared with the results of Kodak extended dose range 2 (EDR2) films. The EBT film had a linear response between the dose range of 0 to 600 cGy. The dose-related characteristics of the EBT film, such as post irradiation color growth with time, film uniformity, and effect of scanning orientation, were studied. There was up to 8.6% increase in the color density between 2 to 40 hours after irradiation. There was a considerable variation, up to 8.5%, in the film uniformity over its sensitive region. The quantitative differences between calculated and measured dose distributions were analyzed using DTA and Gamma index with the tolerance of 3% dose difference and 3-mm distance agreement. The EDR2 films showed consistent results with the calculated dose distributions, whereas the results obtained using EBT were inconsistent. The variation in the film uniformity limits the use of EBT film for conventional large-field IMRT verification. For IMRT of smaller field sizes (4.5 x 4.5 cm), the results obtained with EBT were comparable with results of EDR2 films.

  18. Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification

    International Nuclear Information System (INIS)

    Sankar, A.; Ayyangar, Komanduri M.; Nehru, R. Mothilal; Gopalakrishna Kurup, P.G.; Murali, V.; Enke, Charles A.; Velmurugan, J.

    2006-01-01

    The quantitative dose validation of intensity-modulated radiation therapy (IMRT) plans require 2-dimensional (2D) high-resolution dosimetry systems with uniform response over its sensitive region. The present work deals with clinical use of commercially available self-developing Radio Chromic Film, Gafchromic EBT film, for IMRT dose verification. Dose response curves were generated for the films using a VXR-16 film scanner. The results obtained with EBT films were compared with the results of Kodak extended dose range 2 (EDR2) films. The EBT film had a linear response between the dose range of 0 to 600 cGy. The dose-related characteristics of the EBT film, such as post irradiation color growth with time, film uniformity, and effect of scanning orientation, were studied. There was up to 8.6% increase in the color density between 2 to 40 hours after irradiation. There was a considerable variation, up to 8.5%, in the film uniformity over its sensitive region. The quantitative differences between calculated and measured dose distributions were analyzed using DTA and Gamma index with the tolerance of 3% dose difference and 3-mm distance agreement. The EDR2 films showed consistent results with the calculated dose distributions, whereas the results obtained using EBT were inconsistent. The variation in the film uniformity limits the use of EBT film for conventional large-field IMRT verification. For IMRT of smaller field sizes (4.5 x 4.5 cm), the results obtained with EBT were comparable with results of EDR2 films

  19. Development of an active biodegradable film containing tocopherol and avocado peel extract

    Directory of Open Access Journals (Sweden)

    J.C.F. Fidelis

    2015-12-01

    Full Text Available Thermoplastic starch (TPS films and poly(butylene adipate co-terephthalate (PBAT (60/40 m/m containing TOCO-70 (tocopherol/soybean oil 70/30 m/m and avocado peel extract (ExA were produced using blown film extrusion. The formulations of the 5 films (FC/F1/F2/F3 and F4 were established through mixture design with constraints maintaining constant PBAT and TPS proportion, and varying the antioxidant concentrations. Adding antioxidants reduced the water vapour permeability (Kw of the films, with formulation F2 presenting higher decrease in relationto FC, 77.8%. The presence of ExA improved the mechanical properties of the films. The production of the films was determined to be viable after they presented good processability in a pilotextruder, as well as mechanical properties appropriate to production and utilization in industry.The presence of ExA and TOCO 70 provided the films with antioxidant activity; their application as active packaging requires further studies.

  20. The Herschel Multi-Tiered Extragalactic Survey: SPIRE-mm Photometric Redshifts

    Science.gov (United States)

    Roseboom, I. G.; Ivison, R. J.; Greve, T. R.; Amblard, A.; Arumugam, V.; Auld, R.; Aussel, H.; Bethermin, M.; Blain, A.; Block, J.; hide

    2012-01-01

    We investigate the potential of submm-mm and submm-mm-radio photometric redshifts using a sample of mm-selected sources as seen at 250, 350 and 500 micron by the SPIRE instrument on Herschel. From a sample of 63 previously identified mm sources with reliable radio identifications in the Great Observatories Origins Deep Survey North and Lockman Hole North fields, 46 (73 per cent) are found to have detections in at least one SPIRE band. We explore the observed submm/mm color evolution with redshift, finding that the colors of mm sources are adequately described by a modified blackbody with constant optical depth Tau = (Nu/nu(sub 0))(exp Beta), where Beta = +1.8 and nu(sub 0) = c/100 micron. We find a tight correlation between dust temperature and IR luminosity. Using a single model of the dust temperature and IR luminosity relation, we derive photometric redshift estimates for the 46 SPIRE-detected mm sources. Testing against the 22 sources with known spectroscopic or good quality optical/near-IR photometric redshifts, we find submm/mm photometric redshifts offer a redshift accuracy of (absolute value of Delta sub (z))/(1 + z) = 0.16 (absolute value of Delta sub (z)) = 0.51). Including constraints from the radio-far-IR correlation, the accuracy is improved to (absolute value of Delta sub (z))/(1 + z) = 0.14 (((absolute value of Delta sub (z))) = 0.45). We estimate the redshift distribution of mm-selected sources finding a significant excess at Z > 3 when compared to approx 8S0 micron selected samples.

  1. Comparative study of the displacement of the selected clips in the cavity measured by orthogonal kilovoltage X-ray film in conditions of free breath and active breathing control for patients treated by external-beam partial breast irradiation

    International Nuclear Information System (INIS)

    Li Jianbin; Han Lei; Zhang Yingjie; Xu Min; Fan Tingyong; Shao Qing; Gong Guanzhong

    2010-01-01

    Objective: To compare the displacements of the clips in the cavity measured with orthogonal kilovoltage (KV) X-my plain film in conditions of moderate deep inspiration breathing hold (mDIBH) and free breath (FB), and compare the margins from clinical target volume (CTV) to planning target volume (PTV) based on the displacements. Methods: Before radiotherapy, 2 and 5 sets of orthogonal KV plain film were respectively collected in mDIBH and FB group, then the automatic registration of the reconstructed KV plain film and DRR derived from the planning CT images was finished. In conditions of mDIBH and FB, the displacements of the selected clip at the same location in the different directions and of the different selected clips in the same direction were compared. The margins in three dimensional directions were calculated and compared in conditions of mDIBH and FB. Results: In FB hold group, the difference of displacement in left-right (LR), cranial-caudal (CC) and anterior-posterior (AP) directions were statistically significant between the clips at the cranial and caudal border of the cavity (9.7 mm and 10.6 nun (Z = -2.12, P =0.037) ,7.3 mm and 8.3 mm (Z = -2.31 ,P=0.041) ,15.5 mm and 16.1 nun (Z = -2.32,P = 0.041)), but not statistically significant for the clips at the bottom and lateral P=0.814),15.7 mm and 16.5 mm (Z=-0.26, P=0.856)). The corresponding differences in the different directions were statistically significant (5.0 mm and 7.8 mm(Z = -2.31, P =0.036), 5.0 mm and 9. 3 nun (Z= -2.21, P=0.021), 7.8 mm and 9.3 mm (Z= -2.11, P=0.041)). In FB group, the differences of the displacements of the four selected clips were statistically significant in CC and AP directions (7.3 mm and 8.4 mm (Z= -2.45, P=0.021), 15.5 mm and 16.5 mm (Z= -2.41, P= 0.043)), but not in LF direction (10.6 nun and 10.6 mm (Z= -0.24, P=0.815)). In mDIBH group, the displacements in LF direction were statistically significant (4.4 mm and 5.4 mm (Z = -2.31, P = O. 031)), but not in CC and

  2. [High-contrast resolution of film-screen systems in oral and maxillofacial radiology].

    Science.gov (United States)

    Kaeppler, G; Reinert, S

    2007-11-01

    The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same x-ray units as those used for patient radiographs. The MTF was determined using a lead grid and according to DIN 6867-2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). The relevance of this study is underlined by the diagnostic reference doses defined in the German X-ray Ordinance (RöV) which are also intended for dentistry. Film-screen systems (speed 250, speed class 200) previously used in dental panoramic and cephalometric radiography can be replaced by newly developed film-screen systems (speed class 400). In dental radiography dose reductions are possible with film-screen systems (speed class 400) without impairing diagnostic accuracy. The introduction of newly developed film-screen systems (speed class 400) requires lower milliampere-seconds and therefore an adjustment of the x-ray units to lower milliampere settings.

  3. Investigation on synthesis of Bi-based thin films on flat sputter-deposited Ag film by melting process

    International Nuclear Information System (INIS)

    Su Yanjing; Satoh, Yoshimasa; Arisawa, Shunichi; Awane, Toru; Fukuyo, Akihiro; Takano, Yoshihiko; Ishii, Akira; Hatano, Takeshi; Togano, Kazumasa

    2003-01-01

    We report on the fabrication of ribbon-like thin films on flat sputter-deposited Ag films whose surface smoothness remained within the order of tens of nm. It was found that the addition of Pb to the starting material improves the wettability of molten phase and facilitates the growth of Bi-2212 ribbon-like thin films on a flat Ag substrate, and that the increase of Ca and Cu in starting material suppresses the intergrowth of the Bi-2201 phase in ribbon-like thin films. By using (Bi,Pb)-2246 powders, with nominal composition of Bi 1.6 Pb 0.4 Sr 1.6 Ca 3.2 Cu 4.8 O y , as the starting material, the superconducting Bi-2212 ribbon-like thin films with an onset T c at 74 K on a very flat Ag substrate were successfully synthesized. Additionally, the growth mechanism of ribbon-like thin films on flat Ag substrate was investigated by in situ high temperature microscope observation

  4. Modification of mechanical and thermal property of chitosan–starch blend films

    International Nuclear Information System (INIS)

    Tuhin, Mohammad O.; Rahman, Nazia; Haque, M.E.; Khan, Ruhul A.; Dafader, N.C.; Islam, Rafiqul; Nurnabi, Mohammad; Tonny, Wafa

    2012-01-01

    Chitosan–starch blend films (thickness 0.2 mm) of different composition were prepared by casting and their mechanical properties were studied. To improve the properties of chitosan–starch films, glycerol and mustard oil of different composition were used. Chitosan–starch films, incorporated with glycerol and mustard oil, were further modified with monomer 2-hydroxyethyl methacrylate (HEMA) using gamma radiation. The modified films showed improvement in both tensile strength and elongation at break than the pure chitosan–starch films. Water uptake of the films reduced significantly than the pure chitosan–starch film. Thermo gravimetric analysis (TGA) and dynamic mechanical analysis (DMA) showed that the modified films experience less thermal degradation than the pure films. Scanning electron microscopy (SEM) and FTIR were used to investigate the morphology and molecular interaction of the blend film, respectively. - Highlights: ► Chitosan–starch blend films (thickness 0.2 mm) were prepared by casting. ► To improve the properties of chitosan–starch films, glycerol and mustard oil of different composition were used. ► Chitosan–starch films, incorporated with glycerol and mustard oil, were further modified with monomer 2-hydroxyethyl methacrylate (HEMA) using gamma radiation. ► Properties of the modified films such as tensile strength, elongation at break, water uptake, TGA, DMA, SEM, FTIR were studied. ► Results indicate that modification of chitosan–starch film with mustard oil improved the properties of the blend films which could be further modified by HEMA using gamma radiation.

  5. Development of immobilization devices for patients with pelvic malignancies and a feasibility evaluation during radiotherapy

    International Nuclear Information System (INIS)

    Park, Jong Min; Park, Yang Kyun; Cho, Woong; Park, Charn Il; Ha, Sung Whan

    2007-01-01

    Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were 1.5 ± 0.9 mm, 3.0 ± 3.6 mm, and 1.6 ± 0.9 mm, respectively without devices. The errors were reduced to 1.3 ± 1.9 mm, 1.8 ± 1.5 mm and 1.1 ± 1.1 mm, respectively with the devices. The errors between DRR and portal films were 1.6 ± 1.2 mm, 4.0 ± 4.1 mm, and 4.2 ± 5.5 mm, respectively without the devices and were reduced to 1.0 ± 1.8 mm, 1.2 ± 0.9 mm, and 1.2 ± 0.8 mm, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors

  6. Measurement of liquid film in microchannels using a laser focus displacement meter

    Science.gov (United States)

    Hazuku, Tatsuya; Fukamachi, Norihiro; Takamasa, Tomoji; Hibiki, Takashi; Ishii, Mamoru

    2005-06-01

    This paper presents a new method for measuring the interfacial displacement of a liquid film in microchannels using a laser focus displacement meter (LFD). The purpose of the study is to clarify the effectiveness of the new method for obtaining detailed information concerning interfacial displacement, especially in the case of a thin liquid film, in microchannels and minichannels. To prevent the tube wall signal from disturbing that of the gas liquid interface, a fluorocarbon tube with a water box was used; the refraction index of this device is the same as that for water. With this method, accurate instantaneous measurements of the interfacial displacement of the liquid film were achieved. The error caused by refraction of the laser beam passing through the acrylic water box and fluorocarbon tube was estimated analytically and experimentally. The formulated analytical equation can estimate the real interface displacement by using the measured displacement in a fluorocarbon tube of 25 μm to 2.0 mm I.D. A preliminary test using fluorocarbon tubes of 1 mm and 2 mm I.D. showed that the corrected interface displacement calculated by the equation agreed with the real displacement to within a 1% margin of error. It was also confirmed that the LFD in the system could measure a liquid film of 0.25 μm at the thinnest. We made simultaneous measurements of the interface in fluorocarbon tubes of 0.5 mm and 1 mm I.D. using the LFD and a high-speed video camera with a microscope. These showed that the LFD could measure the interface of a liquid film with high spatial and temporal resolution during annular, slug, and piston flow regimes. The data also clarified the existence of a thin liquid film of less than 1 μm in thickness in the slug and annular flow regimes.

  7. Measurement of liquid film in microchannels using a laser focus displacement meter

    Energy Technology Data Exchange (ETDEWEB)

    Hazuku, Tatsuya; Fukamachi, Norihiro; Takamasa, Tomoji [Tokyo University of Marine Science and Technology, Faculty of Marine Technology, Etchujima, Koto, Tokyo (Japan); Hibiki, Takashi [Kyoto University, Research Reactor Institute, Kumatori, Sennan, Osaka (Japan); Ishii, Mamoru [Purdue University, School of Nuclear Engineering, West Lafayette, IN (United States)

    2005-06-01

    This paper presents a new method for measuring the interfacial displacement of a liquid film in microchannels using a laser focus displacement meter (LFD). The purpose of the study is to clarify the effectiveness of the new method for obtaining detailed information concerning interfacial displacement, especially in the case of a thin liquid film, in microchannels and minichannels. To prevent the tube wall signal from disturbing that of the gas-liquid interface, a fluorocarbon tube with a water box was used; the refraction index of this device is the same as that for water. With this method, accurate instantaneous measurements of the interfacial displacement of the liquid film were achieved. The error caused by refraction of the laser beam passing through the acrylic water box and fluorocarbon tube was estimated analytically and experimentally. The formulated analytical equation can estimate the real interface displacement by using the measured displacement in a fluorocarbon tube of 25 {mu}m to 2.0 mm I.D. A preliminary test using fluorocarbon tubes of 1 mm and 2 mm I.D. showed that the corrected interface displacement calculated by the equation agreed with the real displacement to within a 1% margin of error. It was also confirmed that the LFD in the system could measure a liquid film of 0.25 {mu}m at the thinnest. We made simultaneous measurements of the interface in fluorocarbon tubes of 0.5 mm and 1 mm I.D. using the LFD and a high-speed video camera with a microscope. These showed that the LFD could measure the interface of a liquid film with high spatial and temporal resolution during annular, slug, and piston flow regimes. The data also clarified the existence of a thin liquid film of less than 1 {mu}m in thickness in the slug and annular flow regimes. (orig.)

  8. Preparation and characterization of milk protein films and their application for packaging of Cheddar cheese.

    Science.gov (United States)

    Wagh, Y R; Pushpadass, Heartwin A; Emerald, F Magdaline Eljeeva; Nath, B Surendra

    2014-12-01

    Casein and whey protein concentrate (WPC) films, plasticized with glycerol and sorbitol independently, were prepared by casting. The film thickness, water vapour and oxygen permeation and tensile and moisture sorption properties of the films were determined. The tensile strength (TS), tensile strain (TE) and elastic modulus (EM) of the films ranged from 0.71 to 4.58 MPa, 19.22 to 66.63 % and 2.05 to 6.93 MPa, respectively. The film properties were influenced by the type of biopolymer (casein and whey protein concentrate), plasticizer and its concentration. Increasing the plasticizer concentration, increased the film thickness, TE and water vapour permeability (WVP), but decreased the TS and EM. As the concentration of plasticizer increased to the highest level, the film thickness increased from 0.168 to 0.305 mm for glycerol-plasticized films and from 0.251 to 0.326 mm for sorbitol-plasticized films. The film thickness increased because the amount of plasticizer in the film network increased and the amount of biopolymer remained same. Casein films showed superior tensile properties as compared to WPC films. The WVP of both casein and WPC films lied between 3.87 and 13.97 g.mm./(m(2).h.kPa). The moisture sorption isotherms of both films were typical of high-protein material, and were adequately described by the GAB model. The oxygen permeability of casein films was relatively lower than that of WPC films, regardless of the plasticizer used. The sensory data revealed that the organoleptic quality of Cheddar cheese was unaffected by milk-protein film packaging.

  9. Structural, dielectric and ferroelectric characterization of PZT thin films

    Directory of Open Access Journals (Sweden)

    Araújo E.B.

    1999-01-01

    Full Text Available In this work ferroelectric thin films of PZT were prepared by the oxide precursor method, deposited on Pt/Si substrate. Films of 0.5 mm average thickness were obtained. Electrical and ferroelectric characterization were carried out in these films. The measured value of the dielectric constant for films was 455. Ferroelectricity was confirmed by Capacitance-Voltage (C-V characteristics and P-E hysteresis loops. Remanent polarization for films presented value around 5.0 µC/cm2 and a coercive field of 88.8 kV/cm.

  10. Analysis of vaginal microbicide film hydration kinetics by quantitative imaging refractometry.

    Science.gov (United States)

    Rinehart, Matthew; Grab, Sheila; Rohan, Lisa; Katz, David; Wax, Adam

    2014-01-01

    We have developed a quantitative imaging refractometry technique, based on holographic phase microscopy, as a tool for investigating microscopic structural changes in water-soluble polymeric materials. Here we apply the approach to analyze the structural degradation of vaginal topical microbicide films due to water uptake. We implemented transmission imaging of 1-mm diameter film samples loaded into a flow chamber with a 1.5×2 mm field of view. After water was flooded into the chamber, interference images were captured and analyzed to obtain high resolution maps of the local refractive index and subsequently the volume fraction and mass density of film material at each spatial location. Here, we compare the hydration dynamics of a panel of films with varying thicknesses and polymer compositions, demonstrating that quantitative imaging refractometry can be an effective tool for evaluating and characterizing the performance of candidate microbicide film designs for anti-HIV drug delivery.

  11. Image-receptor performance: a comparison of Trophy RVG UI sensor and Kodak Ektaspeed Plus film.

    Science.gov (United States)

    Ludlow, J; Mol, A

    2001-01-01

    Objective. This study compares the physical characteristics of the RVG UI sensor (RVG) with Ektaspeed Plus film. Dose-response curves were generated for film and for each of 6 available RVG modes. An aluminum step-wedge was used to evaluate exposure latitude. Spatial resolution was assessed by using a line-pair test tool. Latitude and resolution were assessed by observers for both modalities. The RVG was further characterized by its modulation transfer function. Exposure latitude was equal for film and RVG in the periodontal mode. Other gray scale modes demonstrated much lower latitude. The average maximum resolution was 15.3 line-pairs per millimeter (lp/mm) for RVG in high-resolution mode, 10.5 lp/mm for RVG in low-resolution mode, and 20 lp/mm for film (P <.0001). Modulation transfer function measurements supported the subjective assessments. In periodontal mode, the RVG UI sensor demonstrates exposure latitude similar to that of Ektaspeed Plus film. Film images exhibit significantly higher spatial resolution than the RVG images acquired in high-resolution mode.

  12. Development of NaI(Tl) scintillating films for imaging soft x-rays

    International Nuclear Information System (INIS)

    Shepherd, J.A.

    1993-01-01

    Thin film NaI(Tl) scintillators, of areas of up to 130 cm 2 , have been fabricated and characterized for use on soft x-ray imaging photomultiplier tubes. Relevant parameters of photon-counting imaging detectors are defined and used to predict the performance of several materials, including CsI(Na), CsI(Tl), CaF 2 (Eu), Lu 2 (SiO 4 )O:Ce, and NaI(Tl), as thin film scintillators on fiber optic substrates. Also, x-ray imaging methodologies are compared. The NaI(Tl) films were vapor-deposited onto quartz and fiber optic substrates using a powder flash deposition technique. When compared to single crystal NaI(Tl), the films were found to have equally high light yield but lower energy resolution. Light yield optimization was studied in detail including the effects of substrate temperature, activator concentration in the evaporant, and boat temperature. Spatial resolution as well as parallax errors are discussed and measured for film thicknesses up to 61 μm. A technique is described that can substantially increase the light collection of high index films on fiber optic disks. The light collection was improved by 20% by coating the disk with potassium silicate before the NaI(Tl) deposition. Large area films, up to 130 cm 2 , had a spatial uniformity of response within ±1.5% for count rate and ±3.5% for light yield, and their spatial resolution exceeded 16.6 lp mm -1 when deposited onto fiber optic substrates. The 8-keV x-ray detection efficiency of the microchannel plate imaging photomultiplier tube coupled to a NaI(Tl) film scintillator is predicted to be 88%. Other uses for the films are also described

  13. Commissioning a hobby cutting device for radiochromic film preparation.

    Science.gov (United States)

    Zolfaghari, Somayeh; Francis, Kirby E; Kairn, Tanya; Crowe, Scott B

    2017-06-01

    In addition to a high spatial resolution and well characterised dose response, one of the major advantages of radiochromic film as a dosimeter is that sheets of film can be cut into pieces suitable for use as calibration films, and for in vivo and phantom measurements. The cutting of film is typically done using scissors or a guillotine, and this process can be time-consuming, limited in precision, requires extensive handling and does not allow holes to be cut from the film without cutting from an existing edge. This study investigated the use of a Brother ScanNCut hobby cutting system for EBT3 film preparation. The optimal operating parameters (blade size, pressure, speed) that resulted in precise cuts with minimal delamination at cut edges were identified using test cutting patterns. These parameters were then used to cut a large film insert for a stereotactic head phantom for comparison against an insert cut with scissors. While the hobby cutting system caused a wider region of delamination at the film edge (1.8 mm) compared to scissors (1 mm), the hobby cutting system was found to be able to produce reproducible cuts more efficiently and more accurately than scissors. The use of the hobby cutting system is recommended for complex phantom inserts (containing sharp corners or holes for alignment rods) or in situations where large numbers of film pieces need to be prepared.

  14. Film thickness in gas-liquid two-phase flow, (4)

    International Nuclear Information System (INIS)

    Fukano, Toru; Sekoguchi, Kotohiko; Kawakami, Yasushi; Shimizu, Hideo.

    1979-01-01

    This paper reports in detail on the thinning process of water film by means of the drainage that appears directly under an obstacle inserted against the flow into the gas-liquid two-phase flow in a tube. The equipment is the same as that used for the first study, in which the orifice type obstacle of 5 mm long having the area ratio of 0.235 was used. This obstacle is the one for which the most significant drainage was observed in the previous study. The change of liquid film in course of time was measured by the constant current method as described before. First, the premising conditions and duration of the drainage are considered. In the thinning by drainage, water film became about 0.1 mm at the early stage of 0.1 sec from its start, then the whole water film became the flow governed by viscosity (called viscous water film). After this state, the film became thinner very slowly. The viscous film is thicker as it is apart farther from the obstacle. If the flow conditions show significant drainage, the duration of drainage directly under the obstacle is nearly equal to the passing time of gas slug. When the thinning of water film is accelerated by drainage, it might cause the possible disappearance of water film when gas slug passes, even if the thermal load is comparatively low. (Wakatsuki, Y.)

  15. Improved Dielectric Films For Capacitors

    Science.gov (United States)

    Yen, Shiao-Ping S.; Lewis, Carol R.; Cygan, Peter J.; Jow, T. Richard

    1994-01-01

    Dielectric films made from blends of some commercially available high-dielectric-constant cyanoresins with each other and with cellulose triacetate (CTA) have both high dielectric constants and high breakdown strengths. Dielectric constants as high as 16.2. Films used to produce high-energy-density capacitors.

  16. Gafchromic EBT3 film dosimetry in electron beams — energy dependence and improved film read‐out

    Science.gov (United States)

    Ojala, Jarkko; Kaijaluoto, Sampsa; Jokelainen, Ilkka; Kosunen, Antti

    2016-01-01

    For megavoltage photon radiation, the fundamental dosimetry characteristics of Gafchromic EBT3 film were determined in  60Co gamma ray beam with addition of experimental and Monte Carlo (MC)‐simulated energy dependence of the film for 6 MV photon beam and 6 MeV, 9 MeV, 12 MeV, and 16 MeV electron beams in water phantom. For the film read‐out, two phase correction of scanner sensitivity was applied: a matrix correction for scanning area and dose‐dependent correction by iterative procedure. With these corrections, the uniformity of response can be improved to be within ±50 pixel values (PVs). To improve the read‐out accuracy, a procedure with flipped film orientations was established. With the method, scanner uniformity can be improved further and dust particles, scratches and/or dirt on scanner glass can be detected and eliminated. Responses from red and green channels were averaged for read‐out, which decreased the effect of noise present in values from separate channels. Since the signal level with the blue channel is considerably lower than with other channels, the signal variation due to different perturbation effects increases the noise level so that the blue channel is not recommended to be used for dose determination. However, the blue channel can be used for the detection of emulsion thickness variations for film quality evaluations with unexposed films. With electron beams ranging from 6 MeV to 16 MeV and at reference measurement conditions in water, the energy dependence of the EBT3 film is uniform within 0.5%, with uncertainties close to 1.6% (k=2). Including 6 MV photon beam and the electron beams mentioned, the energy dependence is within 1.1%. No notable differences were found between the experimental and MC‐simulated responses, indicating negligible change in intrinsic energy dependence of the EBT3 film for 6 MV photon beam and 6 MeV–16 MeV electron beams. Based on the dosimetric characteristics of the EBT3 film, the read

  17. Kinematics and Mechanics analysis of trap-jaw ant Odontomachus monticola

    Science.gov (United States)

    Hao, Wenteng; Yao, Guang; Zhang, Xiangyu; Zhang, Deyuan

    2018-03-01

    Trap-jaw ants of the genus Odontomachus exhibit spectacularly rapid predatory and fugitive strikes. In order to reveal the extraordinary impact resistance of the apical teeth material, we analyzed the kinematics and mechanics of the closing mandibles. Odontomachus monticola is an Odontomachus species and extensive in China. We video-recorded jaw-strikes to measure the closing velocity and acceleration. The experimental results showed that O. monticola’s mandibles closed at a highest velocity of 35.42 m/s and a highest acceleration of 750,000 m/s2 within an average duration of 0.16 ms. In addition, in order to measure the strike force, we developed an extraordinary measuring method with poly (vinylidene fluoride) (PVDF) piezoelectric film. First, the dynamic calibration of the PVDF piezoelectric film was conducted, then the calibrated piezoelectric film was struck by O. monticola. Finally, the mandible strike force was calculated according to the calibration result and the output signal. The measurements results demonstrated that the strike force ranges from 102.2 N to 235.2 N, which is impressive contrast with O. monticola’s body weight.

  18. Comparison Study of Percutaneous Osseointegrated Bone Conduction Device Complications When Using the 9 mm Abutment Versus 6 mm Abutment at Initial Implantation.

    Science.gov (United States)

    Wise, Sean R; LaRouere, Jacqueline S; Bojrab, Dennis I; LaRouere, Michael J

    2018-04-01

    To assess differences in the incidence, type, and management of complications encountered with implantation of percutaneous osseointegrated bone conduction devices when using a 9 mm abutment versus 6 mm abutment at initial implantation. Retrospective cohort study. One hundred thirty consecutive patients between January 2010 and December 2011 underwent single-stage percutaneous osseointegrated bone conduction device implantation using a 9 or 6 mm abutment. Clinical outcomes assessed for the two groups included the incidence, type, and management of postoperative complications. Abutment size, age, sex, indication for surgery, implant device type, duration of follow-up, and patient comorbidities were evaluated as potential factors affecting outcomes. Average duration of follow-up was 16 months (range 6-29 mo). Postoperative complications occurred in 38 (29.2%) patients. Twenty-four (18.4%) patients experienced minor complications requiring simple, local care; eight (6.1%) patients required in-office procedural intervention; and six (4.6%) patients required revision surgery in the operating room. Implant extrusion occurred in three (2.3%) patients. Eleven (8.5%) patients required placement of a longer abutment. Patients receiving the 6 mm abutment at initial surgery were significantly more likely to encounter a complication requiring in-office procedural intervention or revision surgery (p = 0.001). Minor complications after implantation of percutaneous osseointegrated bone conduction devices are common. The vast majority of these complications are due to localized skin reactions, most of which are readily addressed through local care. Patients receiving the 9 mm abutment during initial implantation are significantly less likely to require in-office procedural intervention or revision surgery postoperatively as compared with those receiving the shorter, 6 mm abutment.

  19. Analysis of vaginal microbicide film hydration kinetics by quantitative imaging refractometry.

    Directory of Open Access Journals (Sweden)

    Matthew Rinehart

    Full Text Available We have developed a quantitative imaging refractometry technique, based on holographic phase microscopy, as a tool for investigating microscopic structural changes in water-soluble polymeric materials. Here we apply the approach to analyze the structural degradation of vaginal topical microbicide films due to water uptake. We implemented transmission imaging of 1-mm diameter film samples loaded into a flow chamber with a 1.5×2 mm field of view. After water was flooded into the chamber, interference images were captured and analyzed to obtain high resolution maps of the local refractive index and subsequently the volume fraction and mass density of film material at each spatial location. Here, we compare the hydration dynamics of a panel of films with varying thicknesses and polymer compositions, demonstrating that quantitative imaging refractometry can be an effective tool for evaluating and characterizing the performance of candidate microbicide film designs for anti-HIV drug delivery.

  20. X-ray radiation damage of organic semiconductor thin films during grazing incidence diffraction experiments

    Energy Technology Data Exchange (ETDEWEB)

    Neuhold, A., E-mail: alfred.neuhold@tugraz.at [Institute of Solid State Physics, Graz University of Technology, Graz (Austria); Novak, J.; Flesch, H.-G.; Moser, A.; Djuric, T. [Institute of Solid State Physics, Graz University of Technology, Graz (Austria); Grodd, L.; Grigorian, S.; Pietsch, U. [Institute of Physics, University Siegen (Germany); Resel, R. [Institute of Solid State Physics, Graz University of Technology, Graz (Austria)

    2012-08-01

    Since modern synchrotrons with highly intense X-ray beams are in use to investigate organic materials, the stability of soft matter materials during beam exposure is a crucial issue. Grazing incidence X-ray diffraction and specular X-ray reflectivity measurements were performed on thin films of organic semiconducting materials, like poly(3-hexylthiophene) (P3HT), sexithiophene and pentacene. These films were irradiated with an average flux density between 10{sup 15} and 10{sup 16} photons/(s mm{sup 2}) and evidenced a different stability in synchrotron X-ray radiation. The semi-crystalline P3HT showed a clear intensity decrease of the 1 0 0 Bragg peak and 0 2 0 Bragg peak compared to the rather stable diffraction features of the molecular crystals sexithiophene and pentacene. The difference in synchrotron X-ray radiation stability is explained by the interaction of the X-ray beam with the individual chemical components in the molecules as well as by the different crystallinities of the materials. Furthermore, the semi-crystalline P3HT film exhibited an increase of film thickness after irradiation and the surface roughness slightly decreased. To summarize, this study shows a strong influence of synchrotron X-ray radiation to specific organic thin films like e.g. P3HT, while others like pentacene and sexithiophene are observed as quite stable.

  1. Efficacy of UV-C irradiation for inactivation of food-borne pathogens on sliced cheese packaged with different types and thicknesses of plastic films.

    Science.gov (United States)

    Ha, Jae-Won; Back, Kyeong-Hwan; Kim, Yoon-Hee; Kang, Dong-Hyun

    2016-08-01

    In this study, the efficacy of using UV-C light to inactivate sliced cheese inoculated with Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes and, packaged with 0.07 mm films of polyethylene terephthalate (PET), polyvinylchloride (PVC), polypropylene (PP), and polyethylene (PE) was investigated. The results show that compared with PET and PVC, PP and PE films showed significantly reduced levels of the three pathogens compared to inoculated but non-treated controls. Therefore, PP and PE films of different thicknesses (0.07 mm, 0.10 mm, and 0.13 mm) were then evaluated for pathogen reduction of inoculated sliced cheese samples. Compared with 0.10 and 0.13 mm, 0.07 mm thick PP and PE films did not show statistically significant reductions compared to non-packaged treated samples. Moreover, there were no statistically significant differences between the efficacy of PP and PE films. These results suggest that adjusted PP or PE film packaging in conjunction with UV-C radiation can be applied to control foodborne pathogens in the dairy industry. Copyright © 2016. Published by Elsevier Ltd.

  2. Low emotional response to traumatic footage is associated with an absence of analogue flashbacks: an individual participant data meta-analysis of 16 trauma film paradigm experiments.

    Science.gov (United States)

    Clark, Ian A; Mackay, Clare E; Holmes, Emily A

    2015-01-01

    Most people will experience or witness a traumatic event. A common occurrence after trauma is the experience of involuntary emotional memories of the traumatic event, herewith "flashbacks". Some individuals, however, report no flashbacks. Prospective work investigating psychological factors associated with an absence of flashbacks is lacking. We performed an individual participant data meta-analysis on 16 experiments (n = 458) using the trauma film paradigm to investigate the association of emotional response to traumatic film footage and commonly collected baseline characteristics (trait anxiety, current depression, trauma history) with an absence of analogue flashbacks. An absence of analogue flashbacks was associated with low emotional response to the traumatic film footage and, to a lesser extent, low trait anxiety and low current depression levels. Trauma history and recognition memory for the film were not significantly associated with an absence of analogue flashbacks. Understanding why some individuals report an absence of flashbacks may aid preventative treatments against flashback development.

  3. Inkjet-printing of indium tin oxide (ITO) films for transparent conducting electrodes

    International Nuclear Information System (INIS)

    Hwang, Myun-sung; Jeong, Bong-yong; Moon, Jooho; Chun, Sang-Ki; Kim, Jihoon

    2011-01-01

    Highlights: → Inkjet printing of ITO films. → Ag-grid was inkjet-printed in between two ITO layers in order to improve the electrical property. → Ag-grid inserted ITO films with 2 mm Ag-grid pitch showed the sheet resistance less than 3.4 Ω/sq and the transmittance higher than 82%. - Abstract: Indium-tin-oxide (ITO) films have been prepared by inkjet-printing using ITO nanoparticle inks. The electrical and optical properties of the ITO films were investigated in order to understand the effects of annealing temperatures under microwave. The decrease in the sheet resistance and resistivity of the inkjet-printed ITO films was observed as the annealing temperature increases. The film annealed at 400 deg. C showed the sheet resistance of 517 Ω/sq with the film thickness of ∼580 nm. The optical transmittance of the films remained constant regardless of their annealing temperatures. In order to further reduce the sheet resistance of the films, Ag-grid was printed in between two layers of inkjet-printed ITO. With 3 mm Ag-grid line-to-line pitch, the Ag-grid inserted ITO film has the sheet resistance of 3.4 Ω/sq and the transmittance of 84% after annealing at 200 deg. C under microwave.

  4. Evaluation and performance of arccheck and film using gamma criteria in pre-treatment quality assurance of stereotactic ablative radiotherapy

    Directory of Open Access Journals (Sweden)

    Prabhakar Ramachandran

    2017-01-01

    Full Text Available Aim: The aim of this study is to assess the use of ArcCHECK (AC as an alternative method to replace film dosimetry for pre-treatment quality assurance (QA of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy (IMRT, and volumetric-modulated arc therapy (VMAT stereotactic ablative radiotherapy (SABR treatment plans. Materials and Methods: Twenty-five patients with a varied diagnosis of lung, spine, sacrum, sternum, ribs, scapula, and femur undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients using ionization chamber and film dosimetry. Measurements were also carried out on an AC phantom. The planned and measured doses from the AC device and EBT3 films were compared using four different gamma criteria: 2%/2 mm, 3%/2 mm, 3%/1 mm, and 3%/3 mm. Results: The mean gamma passing rates at 3%/3 mm for all non-spine SABR cases were 98.79 ± 0.96 and 99.27 ± 1.03 with AC and films, respectively. The mean passing rates at 3%/2 mm for AC and films were 98.76 ± 0.42 and 99.43 ± 0.27 respectively for spine VMAT SABR, and 87.15 ± 2.45 and 99.79 ± 0.14 respectively for spine IMRT SABR. In the case of spine tumors, the gamma criterion was tightened due to the proximity of spinal cord to the planning target volume. Our results show that AC provides good results for all VMAT SABR plans. Conclusion: The AC results at 3%/3 mm were in good agreement with film dosimetry for most cases. We observed a significant reduction in QA time on using AC for SABR QA. This study showed that AC results are comparable to film dosimetry for all studied sites except for spine IMRT SABR.

  5. Evaluation and mitigation of potential errors in radiochromic film dosimetry due to film curvature at scanning.

    Science.gov (United States)

    Palmer, Antony L; Bradley, David A; Nisbet, Andrew

    2015-03-08

    This work considers a previously overlooked uncertainty present in film dosimetry which results from moderate curvature of films during the scanning process. Small film samples are particularly susceptible to film curling which may be undetected or deemed insignificant. In this study, we consider test cases with controlled induced curvature of film and with film raised horizontally above the scanner plate. We also evaluate the difference in scans of a film irradiated with a typical brachytherapy dose distribution with the film naturally curved and with the film held flat on the scanner. Typical naturally occurring curvature of film at scanning, giving rise to a maximum height 1 to 2 mm above the scan plane, may introduce dose errors of 1% to 4%, and considerably reduce gamma evaluation passing rates when comparing film-measured doses with treatment planning system-calculated dose distributions, a common application of film dosimetry in radiotherapy. The use of a triple-channel dosimetry algorithm appeared to mitigate the error due to film curvature compared to conventional single-channel film dosimetry. The change in pixel value and calibrated reported dose with film curling or height above the scanner plate may be due to variations in illumination characteristics, optical disturbances, or a Callier-type effect. There is a clear requirement for physically flat films at scanning to avoid the introduction of a substantial error source in film dosimetry. Particularly for small film samples, a compression glass plate above the film is recommended to ensure flat-film scanning. This effect has been overlooked to date in the literature.

  6. Experimental analysis of silicon oxycarbide thin films and waveguides

    Science.gov (United States)

    Memon, Faisal Ahmed; Morichetti, Francesco; Somaschini, Claudio; Iseni, Giosue; Melloni, Andrea

    2017-05-01

    Silicon oxycarbide (SiOC) thin films are produced with reactive rf magnetron sputtering of a silicon carbide (SiC) target on Si (100) and SiO2/Si substrates under varying deposition conditions. The optical properties of the deposited SiOC thin films are characterized with spectroscopic ellispometry at multiple angles of incidence over a wavelength range 300- 1600 nm. The derived optical constants of the SiOC films are modeled with Tauc-Lorentz model. The refractive index n of the SiOC films range from 1.45 to 1.85 @ 1550 nm and the extinction coefficient k is estimated to be less than 10-4 in the near-infrared region above 1000 nm. The topography of SiOC films is studied with SEM and AFM giving rms roughness of 0.9 nm. Channel waveguides with a SiOC core with a refractive index of 1.7 have been fabricated to demonstrate the potential of sputtered SiOC for integrated photonics applications. Propagation loss as low as 0.39 +/- 0.05 dB/mm for TE and 0.41 +/- 0.05 dB/mm for TM polarizations at telecommunication wavelength 1550 nm is demonstrated.

  7. Optical and Chemical Properties of Mixed-valent Rhenium Oxide Films Synthesized by Reactive DC Magnetron Sputtering

    Science.gov (United States)

    2015-04-03

    films were deposited within a stainless steel high vacuum chamber evacuated to a pressure of 5.3 105 Pa (4 107 Torr). A 3 mm thick, 50 mm diameter...G.E. Jellison, Thin Solid Films 234 (1993) 416 –422. [34] J.I. Pankove, Absorption, in: Optical Processes in Semiconductors, Dover Publications, New

  8. 2D fringe probing of liquid film dynamics of a plug bubble in a micropipe

    International Nuclear Information System (INIS)

    Ji, H F; Qiu, H H

    2009-01-01

    An extended film thickness measurement method that can obtain the liquid film thickness profile of the whole plug bubble in a capillary tube simultaneously is presented. The approach is based on a 2D spatial fringe scattering technique, where the spatial frequency of scattered fringes is a function of liquid film thickness along the micropipe. Laser sheets are used instead of the laser beams, and the width of the laser sheets can be selected to cover the whole measurement field. Capillary tubes, with inner diameters of 1.0 mm and 0.3 mm, and lengths of 125 mm and 65 mm, are used. A gas plug bubble, 2.5–20 mm long, is introduced and moves through the testing part of the tube, which is filled with water as the working fluid. The interference fringes produced by two incident laser sheets are scattered from the interface between gas and water, and captured by a high-speed camera at a speed of up to 2000 frames s −1 . The experimental results show that the improved method can obtain the liquid film thickness profile at the different times and can be used to analyze the status of the plug bubble movement in a micropipe

  9. Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification

    Science.gov (United States)

    Palmer, Antony L.; Dimitriadis, Alexis; Nisbet, Andrew; Clark, Catharine H.

    2015-11-01

    There is renewed interest in film dosimetry for the verification of dose delivery of complex treatments, particularly small fields, compared to treatment planning system calculations. A new radiochromic film, Gafchromic EBT-XD, is available for high-dose treatment verification and we present the first published evaluation of its use. We evaluate the new film for MV photon dosimetry, including calibration curves, performance with single- and triple-channel dosimetry, and comparison to existing EBT3 film. In the verification of a typical 25 Gy stereotactic radiotherapy (SRS) treatment, compared to TPS planned dose distribution, excellent agreement was seen with EBT-XD using triple-channel dosimetry, in isodose overlay, maximum 1.0 mm difference over 200-2400 cGy, and gamma evaluation, mean passing rate 97% at 3% locally-normalised, 1.5 mm criteria. In comparison to EBT3, EBT-XD gave improved evaluation results for the SRS-plan, had improved calibration curve gradients at high doses, and had reduced lateral scanner effect. The dimensions of the two films are identical. The optical density of EBT-XD is lower than EBT3 for the same dose. The effective atomic number for both may be considered water-equivalent in MV radiotherapy. We have validated the use of EBT-XD for high-dose, small-field radiotherapy, for routine QC and a forthcoming multi-centre SRS dosimetry intercomparison.

  10. Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification

    International Nuclear Information System (INIS)

    Palmer, Antony L; Dimitriadis, Alexis; Nisbet, Andrew; Clark, Catharine H

    2015-01-01

    There is renewed interest in film dosimetry for the verification of dose delivery of complex treatments, particularly small fields, compared to treatment planning system calculations. A new radiochromic film, Gafchromic EBT-XD, is available for high-dose treatment verification and we present the first published evaluation of its use. We evaluate the new film for MV photon dosimetry, including calibration curves, performance with single- and triple-channel dosimetry, and comparison to existing EBT3 film. In the verification of a typical 25 Gy stereotactic radiotherapy (SRS) treatment, compared to TPS planned dose distribution, excellent agreement was seen with EBT-XD using triple-channel dosimetry, in isodose overlay, maximum 1.0 mm difference over 200–2400 cGy, and gamma evaluation, mean passing rate 97% at 3% locally-normalised, 1.5 mm criteria. In comparison to EBT3, EBT-XD gave improved evaluation results for the SRS-plan, had improved calibration curve gradients at high doses, and had reduced lateral scanner effect. The dimensions of the two films are identical. The optical density of EBT-XD is lower than EBT3 for the same dose. The effective atomic number for both may be considered water-equivalent in MV radiotherapy. We have validated the use of EBT-XD for high-dose, small-field radiotherapy, for routine QC and a forthcoming multi-centre SRS dosimetry intercomparison. (paper)

  11. Evaluation of different 16-row CT colonography protocols using a porcine model; Evaluation unterschiedlicher 16-Zeilen-CT-Colonographie-Protokolle am Schweinedarmmodell

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Schaefer, J.; Dammann, F.; Heuschmid, M.; Claussen, C.D. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik; Vonthein, R. [Universitaet Tuebingen (Germany). Institut fuer Biometrie

    2004-10-01

    Purpose: To develop and to test an easily produced biological colon model with simulated polypoid lesions. Application of this phantom for the selection of an optimized scan protocol of 16-row CT colonography (CTC) for clinical use. Methods and Material: Six polypoid lesions (1-6 mm) were simulated with sutures on the inner face of a porcine colon segment (20 cm). After distending the colon segment with air, the phantom was placed in a water quench and CT scans were performed on a MDCT-scanner (Somatom Sensation 16, Siemens, Forchheim). At constant values for collimation (16 x 0.75 mm) and voltage (120 kV), 54 different combinations of mAs values (50, 75 and 100 mAs), pitch factors (1, 1.25 and 1.5) and slice thicknesses (0.75, 1.0, 1.5, 2.0, 3.0 and 5.0 mm) were tested systematically. The phantom was scanned in the longitudinal and transverse axis to simulate the different orientation of the colon in the abdomen. Axial slice images and virtual endoscopic views of all data sets were presented separately to 2 radiologists who independently determined number and size of detectable polyps. Dose exposure was measured with an Alderson phantom. Results: The colon model offered a realistic imitation of a polyp-covered, human colon. The experimental set-up allowed a systematic evaluation of polyp detection related to lesion size, orientation of the colon and CTC parameters, with other influencing factors mostly excluded. Polyps were significantly better detected in the longitudinal than in the transverse orientation of the colon. For the detection of lesions of at least 3 mm, a low dose (50 mAs) 16-row CTC should be combined with a pitch of 1.5 and a maximum slice thickness of 3 mm. For the depiction of polyps smaller than 3 mm, slice thickness and pitch should amount to 1 mm and 1.0, respectively. Effective dose of this low dose protocol is 4.08 mSv. (orig.)

  12. High dielectric constant PrYxOy sensing films electrolyte-insulator-semiconductor pH-sensor for the detection of urea

    International Nuclear Information System (INIS)

    Wu, Min-Hsien; Lee, Cheng-Da; Pan, Tung-Ming

    2009-01-01

    In this paper, we describe the structural and sensing properties of high-k PrY x O y sensing films deposited on Si substrates through reactive co-sputtering. Secondary ion mass spectrometry and atomic force microscopy were employed to analyze the compositional and morphological features of these films after annealing at various temperatures. The electrolyte-insulator-semiconductor (EIS) device incorporating a PrY x O y sensing membrane that had been annealed at 800 o C exhibited good sensing characteristics, including a high sensitivity (59.07 mV pH -1 in solutions from pH 2 to 12), a low hysteresis voltage (2.4 mV in the pH loop 7 → 4 → 7 → 10 → 7), and a small drift rate (0.62 mV h -1 in the buffer solution at pH 7). The PrY x O y EIS device also showed a high selective response towards H + . This improvement can be attributed to the small number of crystal defects and the large surface roughness. In addition, the enzymatic EIS-based urea biosensor incorporating a high-k PrY x O y sensing film annealed at 800 o C allowed the potentiometric analysis of urea, at concentrations ranging from 1 to 16 mM, with a sensitivity of 9.59 mV mM -1 .

  13. Influence of indium doping on the properties of zinc tin oxide films and its application to transparent thin film transistors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Mu Hee; Ma, Tae Young, E-mail: tyma@gnu.ac.kr

    2014-01-01

    In this study, the effects of indium (In) doping on the properties of zinc tin oxide (ZTO) films are reported. ZTO films were prepared by RF magnetron sputtering followed by In layer deposition, for use as the diffusion source. In order to protect the In layer from peeling, a second ZTO film was deposited on the In film. The annealing at 400 °C for 30 min was carried out to diffuse In atoms into the ZTO films. The structural, optical, and elemental properties of the annealed ZTO/In/ZTO films were investigated by X-ray diffraction, UV/vis spectrophotometry, and X-ray photoluminescence spectroscopy, respectively. The ZTO transparent thin film transistors employing the ZTO/In/ZTO films as the source/drain were prepared, and the effects of the In doped source/drain on the threshold voltage and mobility were characterized and analyzed. - Highlights: • We successfully doped zinc tin oxide (ZTO) films using In as a diffusion source. • Indium (In) was diffused in both directions with the diffusion coefficient of ∼ 4.3 × 10{sup −16} cm{sup 2}/s. • The mobility of ZTO thin film transistor was increased 1.6-times by adopting the In-diffused source/drain.

  14. Potential of nisin-incorporated sodium caseinate films to control Listeria in artificially contaminated cheese.

    Science.gov (United States)

    Cao-Hoang, Lan; Chaine, Aline; Grégoire, Lydie; Waché, Yves

    2010-10-01

    A sodium caseinate film containing nisin (1000 IU/cm(2)) was produced and used to control Listeria innocua in an artificially contaminated cheese. Mini red Babybel cheese was chosen as a model semi-soft cheese. L. innocua was both surface- and in-depth inoculated to investigate the effectiveness of the antimicrobial film as a function of the distance from the surface in contact with the film. The presence of the active film resulted in a 1.1 log CFU/g reduction in L. innocua counts in surface-inoculated cheese samples after one week of storage at 4 degrees C as compared to control samples. With regard to in-depth inoculated cheese samples, antimicrobial efficiency was found to be dependent on the distance from the surface in contact with the active films to the cheese matrix. The inactivation rates obtained were 1.1, 0.9 and 0.25 log CFU/g for distances from the contact surface of 1 mm, 2 mm and 3 mm, respectively. Our study demonstrates the potential application of sodium caseinate films containing nisin as a promising method to overcome problems associated with post-process contamination, thereby extending the shelf life and possibly enhancing the microbial safety of cheeses. 2010 Elsevier Ltd. All rights reserved.

  15. Positioning X-Ray Film Inside A Flow Splitter

    Science.gov (United States)

    Darter, Charles; Pierce, Darryl

    1990-01-01

    Simple and inexpensive tool ensures secure placement for radiographic inspection. Holder places film positively and securely for x-ray inspection inside sections of tube with splitter welds. V-shaped piece of film fits on arms of holder. With arms squeezed together, holder inserted in opening of neck. Arms of holder cut from 0.020-in. (0.51-mm) thick stock of unspecified material.

  16. Coordinated mm/sub-mm observations of Sagittarius A* in May 2007

    Energy Technology Data Exchange (ETDEWEB)

    Kunneriath, D; Eckart, A; Bertram, T; Konig, S [University of Cologne, Zuelpicher Str. 77, D-50937 Cologne (Germany); Vogel, S [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Sjouwerman, L [National Radio Astronomy Observatory, PO Box 0, Socorro, NM 87801 (United States); Wiesemeyer, H [IRAM, Avenida Divina Pastora, 7, Nuecleo Central, E-18012 Granada (Spain); Schoedel, R [Instituto de AstrofIsica de AndalucIa, Camino Bajo de Huetor 50, 18008 Granada (Spain); Baganoff, F K [Center for Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139-4307 (United States); Morris, M; Mauerhan, J; Meyer, L [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095-1547 (United States); Dovciak, M; Karas, V [Astronomical Institute, Academy of Sciences, BocnI II, CZ-14131 Prague (Czech Republic); Dowries, D [Institut de Radio Astronomie Millimetrique, Domaine Universitaire, 38406 St. Martin d' Heres (France); Krichbaum, T; Lu, R-S [Max-Planck-Institut fuer Radioastronomie, Auf dem Huegel 69, 53121 Bonn (Germany); Krips, M [Harvard-Smithsonian Center for Astrophysics, SMA project, 60 Garden Street, MS 78 Cambridge, MA 02138 (United States); Markoff, S [Astronomical Institute ' Anton Pannekoek' , University of Amsterdam, Kruislaan 403, 1098SJ Amsterdam (Netherlands); Duschl, W J, E-mail: eckart@phl.uni-koeln.de (and others)

    2008-10-15

    At the center of the Milky Way, with a distance of {approx}8 kpc, the compact source Sagittarius A* (SgrA*) can be associated with a super massive black hole of {approx}4x 10{sup 6}M{sub o-dot}. SgrA* shows strong variability from the radio to the X-ray wavelength domains. Here we report on simultaneous NIR/sub-millimeter/X-ray observations from May 2007 that involved the NACO adaptive optics (AO) instrument at the European Southern Observatory's Very Large Telescope, the Australian Telescope Compact Array (ATCA), the US mm-array CARMA, the IRAM 30m mm-telescope, and other telescopes. We concentrate on the time series of mm/sub-mm data from CARMA, ATCA, and the MAMBO bolometer at the IRAM 30m telescope.

  17. Comparison of calcification of pineal, habenular commissure and choroid plexus on plain films and computed tomography

    International Nuclear Information System (INIS)

    Macpherson, P.; Matheson, M.S.

    1979-01-01

    Skull radiographs and CT scans of 1,000 consecutive patients were examined for evidence of calcification in the pineal gland, habenular commissure and choroid plexuses. Plain film results were in agreement with previous surveys suggesting that the CT scan results may be accepted as general findings. Pineal calcification was seen on films in 61% and on CT scans in 83% of those over 30. On both films and CT scans calcification was 10% higher in males. Only 1% had a pineal 12 mm or larger on films. In at least 5% it was impossible to separate the habenula from the pineal by CT: including these, 5% had pineals larger than the accepted upper limit of normal. Measurements from males were 0.4 mm larger than for females on films and 0.2 mm larger on CT scans. Habenular commissure calcification was seen on films in 13% and on CT in 15% of those over 30, being 10% higher in males. Bilateral choroid plexus calcification was seen on frontal films in 15% and on CT in 77% of those over 30. On skull films the frequency of calcification was 2%-3% higher for adult males than females and on CT 7% higher. Calcification was seen on the lateral but not the frontal film in 128 patients. One choroid plexus only was seen on 14/ frontal films and on 49 CT scans. (orig.) 891 AJ/orig. 892 MKO [de

  18. Stress relaxation in SSC 50mm dipole coils

    International Nuclear Information System (INIS)

    Rogers, D.; Markley, F.

    1992-04-01

    We are measuring the stress relaxation of SSC 50mm outer coils with the goal of predicting how much of the coil prestress will be lost while the coils are warehoused between manufacture and cooldown. We manufacture 3 inch (76.2mm) long segments of coil with the same materials and techniques that have been used for prototype coils. We are running four simultaneous tests in an attempt to separate the contributions of the different coil materials. Test one is a completely insulated coil section where the insulation is the all polyamide system being tested at Brookhaven; test two is a wire stack insulated only with the normal Kapton overwrap; test three is a stack of bare cable; and test four is a completely insulated normal coil section. All, except for the bare cable, include the ground insulation. The insulated coil sections are carefully dried before loading and testing in order to eliminate stress changes due to varying moisture content. The temperature dependence of the stress relaxation is being studied separately. Three companion papers presented at this conference will be: (1) ''Temperature dependence of the viscoelastic properties of SSC coil insulation'' (2) ''Measurement of the elastic modulus of Kapton perpendicular to the plane of the film at room and cryogenic temperatures'' (3) ''Theoretical methods for creep and stress relaxation studies of SSC coil.''

  19. Electrical behaviour of heterobimetallic [MM'(EtCS2)4] (MM'=NiPd, NiPt, PdPt) and MM'X-chain polymers [PtM(EtCS2)4I] (M=Ni, Pd).

    Science.gov (United States)

    Givaja, Gonzalo; Castillo, Oscar; Mateo, Eva; Gallego, Almudena; Gómez-García, Carlos J; Calzolari, Arrigo; di Felice, Rosa; Zamora, Félix

    2012-11-26

    Herein, we report the isolation of new heterobimetallic complexes [Ni(0.6)Pd(1.4)(EtCS(2))(4)] (1), [NiPt(EtCS(2))(4)] (2) and [Pd(0.4)Pt(1.6)(EtCS(2))(4)] (3), which were constructed by using transmetallation procedures. Subsequent oxidation with iodine furnished the MM'X monodimensional chains [Ni(0.6)Pt(1.4)(EtCS(2))(4)I] (4) and [Ni(0.1)Pd(0.3)Pt(1.6)(EtCS(2))(4)I] (5). The physical properties of these systems were investigated and the chain structures 4 and 5 were found to be reminiscent of the parent [Pt(2)(EtCS(2))(4)I] species. However, they were more sensitively dependent on the localised nature of the charge on the Ni ion, which caused spontaneous breaking of the conduction bands. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Effect of thin water film on tire/road friction

    OpenAIRE

    BEAUTRU, Yannick; KANE, Malal; CEREZO, Véronique; DO, Minh Tan

    2011-01-01

    Water film on pavement surfaces entails a decrease of friction between the tire and the road. Nevertheless, only effects of water films above 1mm depth were investigated until now, considering hydroplaning risk. From these investigations, formulae were derived to predict the so-called hydroplaning speed at which happen hazardous situations for the driver because there is no more contact between the tire and the road. However, a significant number of accidents occurs on very thin water film su...

  1. Effect of thin water film on tire/road friction

    OpenAIRE

    BEAUTRU, Yannick

    2011-01-01

    Water film on pavement surfaces entails a decrease of friction between the tire and the road. Nevertheless,only effects of water films above 1mm depth were investigated until now, considering hydroplaning risk. From these investigations, formulae were derived to predict the so-called hydroplaning speed at which happen hazardous situations for the driver because there is no more contact between the tire and the road. However, a significant number of accidents occurs on very thin water film suc...

  2. The role of target-to-substrate distance on the DC magnetron sputtered zirconia thin films' bioactivity

    Energy Technology Data Exchange (ETDEWEB)

    Thaveedeetrakul, Arisara [Department of Chemical Engineering, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Witit-anun, Nirun [Department of Physics, Burapha University, Chon Buri (Thailand); Thailand Center of Excellence in Physics, CHE, Ministry of Education, Bangkok (Thailand); Boonamnuayvitaya, Virote, E-mail: virote.boo@kmutt.ac.th [Department of Chemical Engineering, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand)

    2012-01-15

    Zirconium dioxide thin films were deposited on 316L-stainless steel type substrates using DC unbalanced magnetron sputtering. The process parameter of this work was the target-to-substrate distance (d{sub t-s}), which was varied from 60 to 120 mm. The crystal structure and surface topography of zirconium dioxide thin films were characterized by X-ray diffraction (XRD) and atomic force microscopy (AFM). The results demonstrate that all of the ZrO{sub 2} thin films are composed monoclinic phase. The film sputtered at short d{sub t-s} (60 mm) shows a rather heterogeneous, uneven surface. The grain size, roughness, and thickness of thin films were decreased by increasing d{sub t-s}. The bioactivity was assessed by investigating the formation of hydroxyapatite (Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2}) on the thin film surface soaked in simulated body fluids (SBF) for 7 days. XRD and scanning electron microscopy (SEM) were used to verify the formation of apatite layers on the samples. Bone-like apatites were formed on the surface of the ZrO{sub 2} thin film in SBF immersion experiments. A nanocrystalline hydroxyapatite (HA) with a particle size of 2-4 {mu}m was deposited. Higher crystallinity of HA on the surface was observed when the distance d{sub t-s} increased to more than 80 mm. Therefore, it seems that a d{sub t-s} greater than 80 mm is an important sputtering condition for inducing HA on the zirconia film.

  3. Design of the multilayer insulation system for the Superconducting Super Collider 50mm dipole cryostat

    International Nuclear Information System (INIS)

    Boroski, W.N.; Nicol, T.H.; Schoo, C.J.

    1991-03-01

    The development of the multilayer insulation (MLI) system for the Superconducting Super Collider (SSC) 50 mm collider dipole cryostat is an ongoing extension of work conducted during the 40 mm cryostat program. While the basic design of the MLI system for the 50 mm cryostat resembles that of the 40 mm cryostat, results from measurements of MLI thermal performance below 80K have prompted a re-design of the MLI system for the 20K thermal radiation shield. Presented is the design of the MLI system for the 50 mm collider dipole cryostat, with discussion focusing on system performance, blanket geometry, cost-effective fabrication techniques, and built-in quality control measures that assure consistent thermal performance throughout the SSC accelerator. 16 refs., 8 figs., 2 tabs

  4. Strawberries packaged with Polyvinyl Chloride (PVC film/ Morangos embalados com filme de Ppolicloreto de Vinila (PVC

    Directory of Open Access Journals (Sweden)

    Sergio Ruffo Roberto

    2006-06-01

    Full Text Available Strawberries cv. Dover with approximately 75% of their surface with red color was packaged in disposable polyethylene terephthalate (PET container and sealed with PVC film of 15mm thick. Strawberries without film serves as control. The fruits were stored at 12°C for ten days and there were determined during storage time the titratable acidity, solid soluble and vitamin C contents, color, respiration rate, texture and weight loss. After 6 days the strawberries packaged without film had decayed while the fruits packaged with PVC film were in conditions of consumption and commercialization. After 10 days all fruits were inappropriate to consumption. Packages with PVC film extended the shelf life of strawberries preserving the color characteristic of the product and vitamin C content, reducing the respiration rate and weight loss, characterizing this packaging as being adequate to this kind of product.Foram utilizados morangos cv. Dover com aproximadamente 75% de sua superfície com coloração vermelha e embalados em potes de polietileno tereftalato (PET. No tratamento CONTROLE os morangos foram acondicionados sem filme e no tratamento FILME, as embalagens foram seladas com filme de PVC de 15mm de espessura. As frutas foram armazenadas a 12°C por dez dias e foram determinadas ao longo do tempo acidez titulável, sólidos solúveis, vitamina C, cor, taxa de respiração, textura e perda de massa. Após 6 dias de armazenagem os morangos CONTROLE estavam impróprios para consumo pois apresentavam deterioração visível por bolores enquanto que os embalados com PVC estavam em condições de consumo e comercialização. Após 10 dias todos os morangos estavam impróprios para consumo. A embalagem utilizando filme de PVC aumentou a vida de prateleira de morangos em relação aos sem embalagem pois preservou melhor a coloração característica do produto e teor de vitamina C e reduziu as taxas de respiração e de perda de massa, caracterizando a

  5. Antibacterial hydroxypropyl methyl cellulose edible films containing nanoemulsions of Thymus daenensis essential oil for food packaging.

    Science.gov (United States)

    Moghimi, Roya; Aliahmadi, Atousa; Rafati, Hasan

    2017-11-01

    Edible films containing essential oils (EO) as natural antibacterial agents are promising systems for food preservation. In this work, nanoemulsions of Thymus daenensis EO (wild; F1 and cultivated; F2) were loaded in hydroxyl propyl methyl cellulose (HPMC) films and the effect of different parameters (polymer, plasticizer, and EO concentration) on the film properties were analyzed and optimized. Prepared HPMC films were characterized in terms of EO loading, morphology, mechanical properties, and the antibacterial activity. The results of SEM showed uniform incorporation of nanoemulsions into the edible film. Investigation of the mechanical properties of two edible films revealed a plasticizing effect of T. daenensis EO on the films. Also, edible films had noticeable antimicrobial activity against selected microorganisms, i.e. 47.0±2.5mm and 22.6±0.5mm zone of inhibition against S. aureus for films containing F1 and F2, respectively. Incorporation of nanoemulsions into the HPMC films can be used for active food preservation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Sinterização de filmes espessos de Ba(Ti0,85Zr0,15O3 por varredura laser Laser scanning sintering of Ba(Ti0.85Zr0.15O3 thick films

    Directory of Open Access Journals (Sweden)

    E. Antonelli

    2009-03-01

    Full Text Available São apresentados os resultados de sinterização de filmes espessos de BaTi0,85Zr0,15O3 (BTZ15, depositados pela técnica de eletroforese, utilizando como fonte de calor um laser de CO2. A montagem experimental foi otimizada de modo a permitir a sinterização de filmes com dimensões de até 70 mm de comprimento por 10mm de largura e espessuras variáveis. Os processos térmicos envolvidos durante a varredura contínua a laser atuaram de modo similar à sinterização em duas etapas. Os tempos de patamares em cada etapa foram dependentes da velocidade e do número de varreduras. A temperatura máxima que se pode atingir no filme espesso, durante cada varredura e para uma potência nominal do laser fixa, foi correlacionada com a densidade relativa. Após sinterizados, os filmes apresentaram homogeneidade microestrutural e uma porosidade aparente de ~7%.The results for sintering of BaTi0.85Zr0.15O3 (BTZ15 thick films, deposited by electrophoresis, using as heat source a CO2 laser are presented. The characteristics of the experimental apparatus were optimized in such a way as to allow the sintering of thick films whose dimensions were up to 70 mm in length, 10 mm in width and variable thicknesses. The related thermal process during the continuous laser scanning acted in a similar way as a two-step sintering. The step times in each stage were dependent on the speed and scan number. The maximum temperature that can be achieved in the thick film, during each scanning, and for a fixed rated laser power, was correlated with the relative density. After sintering the films presented a microstructural homogeneity and an apparent porosity of ~7%.

  7. Suppressing miRNA-15a/-16 expression by interleukin-6 enhances drug-resistance in myeloma cells

    Directory of Open Access Journals (Sweden)

    Chang Hong

    2011-09-01

    Full Text Available Abstract The bone marrow microenvironment facilitates the survival, differentiation, and proliferation of myeloma (MM cells. This study identified that microRNA-15a and -16 expressions tightly correlated with proliferation and drug sensitivity of MM cells. miRNA-15a/-16 expression in MM cells was significantly increased after treatment with cytotoxic agents. The interaction of bone marrow stromal cells (BMSC with MM cells resulted in decreased miRNA-15a/-16 expression and promoted the survival of the MM cells. Interleukin-6 (IL-6 produced by BMSCs suppressed the expression of miRNA-15a and 16 in a time- and dose- dependent pattern, with the suppression on miRNA-15a being more significant than on miRNA-16. miRNA-15a-transfected MM cells were found to be arrested in G1/S checkpoint, and the transfected MM cells had decreased growth and survival. In conclusion, our data suggest that via suppressing miRNA-15a and -16 expressions, IL-6 secreted by BMSCs promotes drug-resistance in myeloma cells.

  8. Mechanical Integrity of Flexible In-Zn-Sn-O Film for Flexible Transparent Electrode

    Science.gov (United States)

    Kim, Young Sung; Oh, Se-In; Choa, Sung-Hoon

    2013-05-01

    The mechanical integrity of transparent In-Zn-Sn-O (IZTO) films is investigated using outer/inner bending, stretching, and twisting tests. Amorphous IZTO films are grown using a pulsed DC magnetron sputtering system with an IZTO target on a polyimide substrate at room temperature. Changes in the optical and electrical properties of IZTO films depend on the oxygen partial pressure applied during the film deposition process. In the case of 3% oxygen partial pressure, the IZTO films exhibit s resistivity of 8.3×10-4 Ω cm and an optical transmittance of 86%. The outer bending test shows that the critical bending radius decreases from 10 to 7.5 mm when the oxygen partial pressure is increased from 1 to 3%. The inner bending test reveals that the critical bending radius of all IZTO films is 3.5 mm regardless of oxygen partial pressure. The IZTO films also show excellent mechanical reliability in the bending fatigue tests of more than 10,000 cycles. In the uniaxial stretching tests, the electrical resistance of the IZTO film does not change until a strain of 2.4% is reached. The twisting tests demonstrate that the electrical resistance of IZTO films remains unchanged up to 25°. These results suggest that IZTO films have excellent mechanical durability and flexibility in comparison with already reported crystallized indium tin oxide (ITO) films.

  9. Effect of gamma radiation on the mechanical and barrier properties of HEMA grafted chitosan-based films

    International Nuclear Information System (INIS)

    Khan, Avik; Huq, Tanzina; Khan, Ruhul A.; Dussault, Dominic; Salmieri, Stephane; Lacroix, Monique

    2012-01-01

    Chitosan films were prepared by dissolving 1% (w/v) chitosan powder in 2% (w/v) aqueous acetic acid solution. Chitosan films were prepared by solution casting. The values of puncture strength (PS), viscoelasticity coefficient and water vapor permeability (WVP) of the films were found to be 565 N/mm, 35%, and 3.30 g mm/m 2 day kPa, respectively. Chitosan solution was exposed to gamma irradiation (0.1–5 kGy) and it was revealed that PS values were reduced significantly (p≤0.05) after 1 kGy dose and it was not possible to form films after 5 kGy. Monomer, 2-hydroxyethyl methacrylate (HEMA) solution (0.1–1%, w/v) was incorporated into the chitosan solution and the formulation was exposed to gamma irradiation (0.3 kGy). A 0.1% (w/v) HEMA concentration at 0.3 kGy dose was found optimal-based on PS values for chitosan grafting. Then radiation dose (0.1–5 kGy) was optimized for HEMA grafting. The highest PS values (672 N/mm) were found at 0.7 kGy. The WVP of the grafted films improved significantly (p≤0.05) with the rise of radiation dose. - highlights: ► HEMA and Silane monomer were incorporated into the MC-based formulation and films. ► Films were exposed to gamma radiation. ► HEMA containing films showed the highest PS values. ► Surface morphology of the grafted films suggested better appearance.

  10. SSC 40 mm cable results and 50 mm design discussions

    International Nuclear Information System (INIS)

    Christopherson, D.; Capone, D.; Hannaford, R.; Remsbottom, R.; Delashmit, R.; Jayakumar, R.J.; Snitchler, G.; Scanlan, R.; Royet, J.

    1991-01-01

    This paper presents a summary of the cable produced for the 1990 40 mm Dipole Program. The cable design parameters for the 50 mm Dipole Program are discussed, as well as portions of the SSC specification draft. Considerations leading to the final cable configuration and the results of preliminary trials are included. The first iteration of a strand mapping program to automate cable strand maps is introduced

  11. Application of tot’hema eosin sensitized gelatin film for adaptive microlenses

    Directory of Open Access Journals (Sweden)

    Murić Branka D.

    2017-01-01

    Full Text Available In this paper we showed that tot’hema eosin sensitized gelatin (TESG film can be used for adaptive microlenses fabriacation. The mechanical properties of a pure gelatin film were improved by adding tot’hema solution. We found that the elasticity of TESG film depend on the tot’hema concentration. By stretching the film, the microlenses were deformed uniaxially, and microlenses focal length can be tuned. The achieved microlenses focal lengths range from 0.05 to 0.2 mm.

  12. Properties of sericin films crosslinking with dimethylolurea

    International Nuclear Information System (INIS)

    Turbiani, Franciele R.B.; Stroher, Gylles Ricardo; Tomadon Junior, Jose; Seixas, Fernanda L.; Stroher, Gylles Ricardo; Gimenes, Marcelino L.

    2011-01-01

    Sericin is a natural silk protein which is removed from silk in a process called degumming. Thus, finding a use for the extracted sericin as a bio polymer film will create added value product which will benefit both the economy and society. The films were manufactured with silk sericin, using different dimethylolurea (DMU) concentrations as cross-linking agent and glycerol as plasticizer. Sericin films produced by crosslinking method were light yellow, homogeneous, transparent and visually attractive. The average film thickness was 0.10 ± 0.02 mm. The bio films show low water solubility (up to 30% of total dry mass), good tension strength and high elongation ability. The water vapor permeability is moderate, typical of highly hydrophilic films. Structural transformations in silk sericin films were analyzed using Fourier transform infrared-attenuated total reflection (FTIR-ATR) spectroscopy and X-ray diffraction. This resulted in aggregated β-sheet structure (peak at 1616 cm-1 in the amide I absorption) by FTIR studies and increasing the DMU concentration in film decreased the peak intensity at 2θ = 20 degree. Sericin-based film properties are dependent on components used to form film, which can used to tailor the desired film flexibility and minimize permeability of films. (author)

  13. Properties of sericin films crosslinking with dimethylolurea

    Energy Technology Data Exchange (ETDEWEB)

    Turbiani, Franciele R.B.; Stroher, Gylles Ricardo [Federal Technology University - UTFPR, Campus Apucarana, PR (Brazil); Tomadon, Junior, Jose; Seixas, Fernanda L; Stroher, Gylles Ricardo; Gimenes, Marcelino L., E-mail: francieler@utfpr.edu.br [State University of Maringa. UEM, Campus Maringa, PR (Brazil)

    2011-07-01

    Sericin is a natural silk protein which is removed from silk in a process called degumming. Thus, finding a use for the extracted sericin as a bio polymer film will create added value product which will benefit both the economy and society. The films were manufactured with silk sericin, using different dimethylolurea (DMU) concentrations as cross-linking agent and glycerol as plasticizer. Sericin films produced by crosslinking method were light yellow, homogeneous, transparent and visually attractive. The average film thickness was 0.10 {+-} 0.02 mm. The bio films show low water solubility (up to 30% of total dry mass), good tension strength and high elongation ability. The water vapor permeability is moderate, typical of highly hydrophilic films. Structural transformations in silk sericin films were analyzed using Fourier transform infrared-attenuated total reflection (FTIR-ATR) spectroscopy and X-ray diffraction. This resulted in aggregated {beta}-sheet structure (peak at 1616 cm-1 in the amide I absorption) by FTIR studies and increasing the DMU concentration in film decreased the peak intensity at 2{theta} = 20 degree. Sericin-based film properties are dependent on components used to form film, which can used to tailor the desired film flexibility and minimize permeability of films. (author)

  14. The integration of InGaP LEDs with CMOS on 200 mm silicon wafers

    Science.gov (United States)

    Wang, Bing; Lee, Kwang Hong; Wang, Cong; Wang, Yue; Made, Riko I.; Sasangka, Wardhana Aji; Nguyen, Viet Cuong; Lee, Kenneth Eng Kian; Tan, Chuan Seng; Yoon, Soon Fatt; Fitzgerald, Eugene A.; Michel, Jurgen

    2017-02-01

    The integration of photonics and electronics on a converged silicon CMOS platform is a long pursuit goal for both academe and industry. We have been developing technologies that can integrate III-V compound semiconductors and CMOS circuits on 200 mm silicon wafers. As an example we present our work on the integration of InGaP light-emitting diodes (LEDs) with CMOS. The InGaP LEDs were epitaxially grown on high-quality GaAs and Ge buffers on 200 mm (100) silicon wafers in a MOCVD reactor. Strain engineering was applied to control the wafer bow that is induced by the mismatch of coefficients of thermal expansion between III-V films and silicon substrate. Wafer bonding was used to transfer the foundry-made silicon CMOS wafers to the InGaP LED wafers. Process trenches were opened on the CMOS layer to expose the underneath III-V device layers for LED processing. We show the issues encountered in the 200 mm processing and the methods we have been developing to overcome the problems.

  15. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.

    Science.gov (United States)

    McCaw, Travis J; Micka, John A; DeWerd, Larry A

    2014-05-01

    Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. A film stack dosimeter was developed using Gafchromic(®) EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the beam axis is parallel to the film

  16. Modification of mechanical and thermal property of chitosan-starch blend films

    Science.gov (United States)

    Tuhin, Mohammad O.; Rahman, Nazia; Haque, M. E.; Khan, Ruhul A.; Dafader, N. C.; Islam, Rafiqul; Nurnabi, Mohammad; Tonny, Wafa

    2012-10-01

    Chitosan-starch blend films (thickness 0.2 mm) of different composition were prepared by casting and their mechanical properties were studied. To improve the properties of chitosan-starch films, glycerol and mustard oil of different composition were used. Chitosan-starch films, incorporated with glycerol and mustard oil, were further modified with monomer 2-hydroxyethyl methacrylate (HEMA) using gamma radiation. The modified films showed improvement in both tensile strength and elongation at break than the pure chitosan-starch films. Water uptake of the films reduced significantly than the pure chitosan-starch film. Thermo gravimetric analysis (TGA) and dynamic mechanical analysis (DMA) showed that the modified films experience less thermal degradation than the pure films. Scanning electron microscopy (SEM) and FTIR were used to investigate the morphology and molecular interaction of the blend film, respectively.

  17. Heat transfer under transition and film boiling of liquids at dimpled spheres and cylinders

    Science.gov (United States)

    Zhukov, V. M.; Kuzma-Kichta, Yu. A.; Lavrikov, A. V.; Belov, K. I.; Len’kov, V. A.

    2018-03-01

    The article presents the results of studies of heat transfer and film and transition boiling mechanism of nitrogen, Refrigerant R-113, and water at spheres and vertical cylinders, which surfaces are covered with spherical dimples.. The data were obtained under the conditions of pool boiling and natural circulation in vertical 1.0 and 2.5 mm wide annular channels. Hemispherical dimples of 3 mm diameter (h/d = 0.17) were made on sample surfaces. The dimples occupied 45% of the sphere surface and 37% of the cylinder surface. In some tests, the dimpled surface was additionally covered with low-conductive coating (10 µm film). Minimal cooling time for the sphere with dimples and low-conductive coating took place under natural circulation in 2.5 mm annular gap and it was almost 2.5 times lower than that for a smooth sphere under pool boiling. It is shown that at pool boiling the presence of dimples and low-conductive coating leads to heat transfer enhancement at transition and film boiling regimes, while at natural circulation such an enhancement occurs at film boiling with high temperature differences. The tests at natural circulation in vertical annular channels of different width showed that in this case an intensity of boiling heat transfer is higher than that at pool boiling. High-speed filming of film boiling process on the surfaces with dimples was conducted.

  18. Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging

    International Nuclear Information System (INIS)

    Ford, E.C.; Mageras, G.S.; Yorke, E.; Rosenzweig, K.E.; Wagman, R.; Ling, C.C.

    2002-01-01

    Purpose: To evaluate the effectiveness of a commercial system in reducing respiration-induced treatment uncertainty by gating the radiation delivery. Methods and Materials: The gating system considered here measures respiration from the position of a reflective marker on the patient's chest. Respiration-triggered planning CT scans were obtained for 8 patients (4 lung, 4 liver) at the intended phase of respiration (6 at end expiration and 2 at end inspiration). In addition, fluoroscopic movies were recorded simultaneously with the respiratory waveform. During the treatment sessions, gated localization films were used to measure the position of the diaphragm relative to the vertebral bodies, which was compared to the reference digitally reconstructed radiograph derived from the respiration-triggered planning CT. Variability was quantified by the standard deviation about the mean position. We also assessed the interfraction variability of soft tissue structures during gated treatment in 2 patients using an amorphous silicon electronic portal imaging device. Results: The gated localization films revealed an interfraction patient-averaged diaphragm variability of 2.8±1.0 mm (error bars indicate standard deviation in the patient population). The fluoroscopic data yielded a patient-averaged intrafraction diaphragm variability of 2.6±1.7 mm. With no gating, this intrafraction excursion became 6.9±2.1 mm. In gated localization films, the patient-averaged mean displacement of the diaphragm from the planning position was 0.0±3.9 mm. However, in 4 of the 8 patients, the mean (over localization films) displacement was >4 mm, indicating a systematic displacement in treatment position from the planned one. The position of soft tissue features observed in portal images during gated treatments over several fractions showed a mean variability between 2.6 and 5.7 mm. The intrafraction variability, however, was between 0.6 and 1.4 mm, indicating that most of the variability was

  19. Verification of Gamma Knife extend system based fractionated treatment planning using EBT2 film

    Energy Technology Data Exchange (ETDEWEB)

    Natanasabapathi, Gopishankar; Bisht, Raj Kishor [Gamma Knife Unit, Department of Neurosurgery, Neurosciences Centre, All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110029 (India)

    2013-12-15

    Purpose: This paper presents EBT2 film verification of fractionated treatment planning with the Gamma Knife (GK) extend system, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery.Methods: A human head shaped phantom simulated the verification process for fractionated Gamma Knife treatment. Phantom preparation for Extend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, and acquiring a stereotactic computed tomography (CT) scan. A CT scan (Siemens, Emotion 6) of the phantom was obtained with following parameters: Tube voltage—110 kV, tube current—280 mA, pixel size—0.5 × 0.5 and 1 mm slice thickness. A treatment plan with two 8 mm collimator shots and three sectors blocking in each shot was made. Dose prescription of 4 Gy at 100% was delivered for the first fraction out of the two fractions planned. Gafchromic EBT2 film (ISP Wayne, NJ) was used as 2D verification dosimeter in this process. Films were cut and placed inside the film insert of the phantom for treatment dose delivery. Meanwhile a set of films from the same batch were exposed from 0 to 12 Gy doses for calibration purposes. An EPSON (Expression 10000 XL) scanner was used for scanning the exposed films in transparency mode. Scanned films were analyzed with inhouse written MATLAB codes.Results: Gamma index analysis of film measurement in comparison with TPS calculated dose resulted in high pass rates >90% for tolerance criteria of 1%/1 mm. The isodose overlay and linear dose profiles of film measured and computed dose distribution on sagittal and coronal plane were in close agreement.Conclusions: Through this study, the authors propose treatment verification QA method for Extend frame based fractionated Gamma Knife radiosurgery using EBT2 film.

  20. Verification of Gamma Knife extend system based fractionated treatment planning using EBT2 film

    International Nuclear Information System (INIS)

    Natanasabapathi, Gopishankar; Bisht, Raj Kishor

    2013-01-01

    Purpose: This paper presents EBT2 film verification of fractionated treatment planning with the Gamma Knife (GK) extend system, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery.Methods: A human head shaped phantom simulated the verification process for fractionated Gamma Knife treatment. Phantom preparation for Extend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, and acquiring a stereotactic computed tomography (CT) scan. A CT scan (Siemens, Emotion 6) of the phantom was obtained with following parameters: Tube voltage—110 kV, tube current—280 mA, pixel size—0.5 × 0.5 and 1 mm slice thickness. A treatment plan with two 8 mm collimator shots and three sectors blocking in each shot was made. Dose prescription of 4 Gy at 100% was delivered for the first fraction out of the two fractions planned. Gafchromic EBT2 film (ISP Wayne, NJ) was used as 2D verification dosimeter in this process. Films were cut and placed inside the film insert of the phantom for treatment dose delivery. Meanwhile a set of films from the same batch were exposed from 0 to 12 Gy doses for calibration purposes. An EPSON (Expression 10000 XL) scanner was used for scanning the exposed films in transparency mode. Scanned films were analyzed with inhouse written MATLAB codes.Results: Gamma index analysis of film measurement in comparison with TPS calculated dose resulted in high pass rates >90% for tolerance criteria of 1%/1 mm. The isodose overlay and linear dose profiles of film measured and computed dose distribution on sagittal and coronal plane were in close agreement.Conclusions: Through this study, the authors propose treatment verification QA method for Extend frame based fractionated Gamma Knife radiosurgery using EBT2 film

  1. GAFChromic film dosimetry with a flatbed color scanner for Leksell Gamma Knife therapy

    International Nuclear Information System (INIS)

    Yamauchi, M.; Tominaga, T.; Nakamura, O.; Ueda, R.; Hoshi, M.

    2004-01-01

    GAFChromic films MD-55-2 have recently been established widely in industrial, scientific, and medical applications as radiation dosimeters. We applied these films to the dosimetry for Leksell Gamma Knife therapy. We used a flatbed image scanner to take digital images of irradiated MD-55-2, and the data were converted to Red, Green and Blue pixel values. The absorbed dose, as derived from the response curve of the Red pixel value, was consistent with the Leksell Gamma Plan dose planning system, for exposures using collimator sizes, 4 mm, 8 mm, and 14 mm. However, the maximum dose in the exposure of the 18 mm collimator was measured to be about 5% smaller than Gamma Plan due to the density effect of the compound material in the head phantom

  2. Effects of Long-Term Static Bending Deformation on a Barrier Thin Film for Flexible Organic Optoelectronic Devices

    Directory of Open Access Journals (Sweden)

    Hung-I Lu

    2018-03-01

    Full Text Available The objective of this study is to investigate the effect of long-term static bending on the encapsulation properties of a commercial barrier thin film for flexible optoelectronic devices. Encapsulation properties of the barrier film are evaluated under long-term static bending at various radii of curvature. Experimental results reveal that no significantly detrimental effect on the water vapor transmission rate (WVTR at 40 °C and 90% RH is found for compressive bending up to 1000 h and for tensile bending up to 100 h with a radius of curvature of 5 mm or larger. However, WVTR of the barrier thin film is significantly increased and cracks are found in the barrier film when subjected to tensile bending of a radius of 10 mm or 5 mm for 1000 h. The expected WVTR of the given barrier thin film is numerically computed using a three-dimensional (3D finite element model. Numerical results indicate that, with the presence of cracks in the barrier thin film, the WVTR increases for an apparent increase in moisture entrances. The WVTR calculated by the 3D cracking model concurs with the experimental results.

  3. Alignment verification in stereotactic radiosurgery with use of graphic arts film

    International Nuclear Information System (INIS)

    Sweet, J.; Lamba, M.

    1990-01-01

    This paper evaluates the use of graphic arts film for field alignment verification of linear accelerator-based stereotactic radiosurgery. The characteristic curve was generated for Fuji RO-100 graphic arts film in a standard leaded radiation therapy cassette at 6 MV. The linear portion of the curve and the film contrast are presented and their clinical advantages discussed. The high contrast of this graphic arts film improves visualization of the 5-mm ball bearing (simulated target) in small, circular treatment fields. Comparison with standard port film demonstrates the large linear range of the graphic arts film, which proved useful in visualization of the simulated target within the small, circular treatment field

  4. Residual stress and bending strength of ZnO films deposited on polyimide sheet by RF sputtering system

    Energy Technology Data Exchange (ETDEWEB)

    Kusaka, Kazuya, E-mail: kusaka@tokushima-u.ac.jp [Institute of Technology and Science, Tokushima University, 2-1, Minamijosanjima, Tokushima, Tokushima 7708506 (Japan); Maruoka, Yutaka, E-mail: ymaruoka1116@gmail.com [Graduate School of Advanced Technology and Science, Tokushima University, 2-1, Minamijosanjima, Tokushima, Tokushima 7708506 (Japan); Matsue, Tatsuya, E-mail: tmatsue@mat.niihama-nct.ac.jp [Department of Environmental Materials Engineering National Institute of Technology, NIIHAMA College, 7-1, Yakumo-cho, Niihama, Ehime 7928580 (Japan)

    2016-05-15

    Zinc oxide (ZnO) films were deposited on a soft polyimide sheet substrate by radio frequency sputtering with a ZnO powder target, and the films' crystal orientations and residual stress were investigated using x-ray diffraction as a function of substrate temperature. C-axis oriented ZnO films were achieved using this ZnO powder target method. The ZnO films exhibited high compressive residual stresses between −0.7 and −1.4 GPa. Finally, the authors examined the strength of the obtained film by applying tensile bending loads. No cracks were observed on the surfaces of the ZnO films after a bending test using cylinders with diameters >25 mm. After a bending test using a cylinder with a diameter of 19 mm, large cracks were formed on the films. Therefore, the authors concluded that the tensile bending strength of the obtained films was greater than ∼420 MPa.

  5. A comparative study of shadow shield whole body monitor incorporated with 203 mm dia. x 102 mm thick and 102 mm dia. x 76 mm thick NaI(TI) detectors

    International Nuclear Information System (INIS)

    Sankhla, Rajesh; Singh, I.S.; Rao, D.D.

    2016-01-01

    The whole body counting using Shadow Shield Whole Body Monitor (SSWBM) proved to be a popular method for assessment of internal contamination due to high energy gamma (E>200 keV) emitting radio nuclides that got inadvertently incorporated in the occupational workers. Currently ∼ 5 SSWBMs are operational at various DAE nuclear facilities throughout the country. The shielding of SSWBMs are said to be designed for 102 mm x 76 mm NaI(Tl) detector and over a period of time, the same concept is being followed. At present, the number of subjects monitored per annum has increased significantly compared to earlier years due to the increase in nuclear facilities at different sites and also increase in number of contract personnel. Aim of this study is to develop/upgrade the existing SSWBMs to increase their capabilities in terms of throughput without compromising on sensitivity. This work includes response studies of individual detectors of sizes 102 mm x 76 mm and 203 mm x 102 mm housed in SSWBM in terms of background, efficiency and Minimum Detection Activity (MDA) for different gamma emitting radio nuclides using Bhabha Atomic Research Centre reference Bottle Mannequin ABsorption (BOMAB) phantom

  6. Third generation biosensing matrix based on Fe-implanted ZnO thin film

    Science.gov (United States)

    Saha, Shibu; Gupta, Vinay; Sreenivas, K.; Tan, H. H.; Jagadish, C.

    2010-09-01

    Third generation biosensor based on Fe-implanted ZnO (Fe-ZnO) thin film has been demonstrated. Implantation of Fe in rf-sputtered ZnO thin film introduces redox center along with shallow donor level and thereby enhance its electron transfer property. Glucose oxidase (GOx), chosen as model enzyme, has been immobilized on the surface of the matrix. Cyclic voltammetry and photometric assay show that the prepared bioelectrode, GOx/Fe-ZnO/ITO/Glass is sensitive to the glucose concentration with enhanced response of 0.326 μA mM-1 cm-2 and low Km of 2.76 mM. The results show promising application of Fe-implanted ZnO thin film as an attractive matrix for third generation biosensing.

  7. Third generation biosensing matrix based on Fe-implanted ZnO thin film

    International Nuclear Information System (INIS)

    Saha, Shibu; Gupta, Vinay; Sreenivas, K.; Tan, H. H.; Jagadish, C.

    2010-01-01

    Third generation biosensor based on Fe-implanted ZnO (Fe-ZnO) thin film has been demonstrated. Implantation of Fe in rf-sputtered ZnO thin film introduces redox center along with shallow donor level and thereby enhance its electron transfer property. Glucose oxidase (GOx), chosen as model enzyme, has been immobilized on the surface of the matrix. Cyclic voltammetry and photometric assay show that the prepared bioelectrode, GOx/Fe-ZnO/ITO/Glass is sensitive to the glucose concentration with enhanced response of 0.326 μA mM -1 cm -2 and low Km of 2.76 mM. The results show promising application of Fe-implanted ZnO thin film as an attractive matrix for third generation biosensing.

  8. Nb3Ge superconductive films grown with nitrogen

    International Nuclear Information System (INIS)

    Sigsbee, R.A.

    1978-01-01

    A superconductive film of Nb 3 Ge is produced by providing within a vacuum chamber a heated substrate and sources of niobium and germanium, reducing the pressure within the chamber to a residual pressure no greater than about 10 -5 mm Hg, introducing nitrogen into the resulting evacuated chamber in controlled amounts and vaporizing the niobium and germanium to deposit a film of Nb 3 Ge on the heated substrate

  9. Langmuir-Blodgett film based on MEH-PPV for cholesterol biosensor

    International Nuclear Information System (INIS)

    Matharu, Zimple; Arya, Sunil K.; Singh, S.P.; Gupta, Vinay; Malhotra, B.D.

    2009-01-01

    Cholesterol oxidase (ChOx) has been immobilized onto conducting poly[2-methoxy,5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV)/stearic acid (SA) Langmuir-Blodgett film transferred onto octadecanethiol (ODT) modified gold plate. The ChOx/MEH-PPV/SA LB film bioelectrode exhibits has been characterized by FT-IR, contact angle, and atomic force microscopy. The response of the ChOx/MEH-PPV/SA LB film bioelectrode carried out using differential pulse voltammetry (DPV) studies reveal linearity from 1.29 to 12.91 mM of cholesterol concentration and response time as 30 s. This ChOx/MEH-PPV/SA bioelectrode exhibits values of correlation coefficient as 0.9939, standard deviation as 0.0029 μA and limit of detection as 1.66 mM. UV-visible spectrophotometer studies reveal that 5.2 x 10 -3 U of ChOx are actively working per cm 2 area of ChOx/MEH-PPV/SA LB film bioelectrode and this bioelectrode is thermally stable upto 55 deg. C with reusability of about 60 times

  10. Langmuir-Blodgett film based on MEH-PPV for cholesterol biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Matharu, Zimple [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Arya, Sunil K.; Singh, S.P. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Gupta, Vinay [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Malhotra, B.D. [Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012 (India)], E-mail: bansi.malhotra@gmail.com

    2009-02-23

    Cholesterol oxidase (ChOx) has been immobilized onto conducting poly[2-methoxy,5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV)/stearic acid (SA) Langmuir-Blodgett film transferred onto octadecanethiol (ODT) modified gold plate. The ChOx/MEH-PPV/SA LB film bioelectrode exhibits has been characterized by FT-IR, contact angle, and atomic force microscopy. The response of the ChOx/MEH-PPV/SA LB film bioelectrode carried out using differential pulse voltammetry (DPV) studies reveal linearity from 1.29 to 12.91 mM of cholesterol concentration and response time as 30 s. This ChOx/MEH-PPV/SA bioelectrode exhibits values of correlation coefficient as 0.9939, standard deviation as 0.0029 {mu}A and limit of detection as 1.66 mM. UV-visible spectrophotometer studies reveal that 5.2 x 10{sup -3} U of ChOx are actively working per cm{sup 2} area of ChOx/MEH-PPV/SA LB film bioelectrode and this bioelectrode is thermally stable upto 55 deg. C with reusability of about 60 times.

  11. Cell Adhesion and Proliferation on Sulfonated and Non-Modified Chitosan Films.

    Science.gov (United States)

    Martínez-Campos, Enrique; Civantos, Ana; Redondo, Juan Alfonso; Guzmán, Rodrigo; Pérez-Perrino, Mónica; Gallardo, Alberto; Ramos, Viviana; Aranaz, Inmaculada

    2017-05-01

    Three types of chitosan-based films have been prepared and evaluated: a non-modified chitosan film bearing cationizable aliphatic amines and two films made of N-sulfopropyl chitosan derivatives bearing both aliphatic amines and negative sulfonate groups at different ratios. Cell adhesion and proliferation on chitosan films of C2C12 pre-myoblastic cells and B16 cells as tumoral model have been tested. A differential cell behavior has been observed on chitosan films due to their different surface modification. B16 cells have shown lower vinculin expression when cultured on sulfonated chitosan films. This study shows how the interaction among cells and material surface can be modulated by physicochemical characteristics of the biomaterial surface, altering tumoral cell adhesion and proliferation processes.

  12. SSC 40 mm cable results and 50 mm design discussions

    International Nuclear Information System (INIS)

    Christopherson, D.; Capone, D.; Hannaford, R.; Remsbottom, R.; Jayakumar, R.; Snitchler, G.; Scanlan, R.; Royet, J.

    1990-09-01

    A summary of the cable produced for the 1990 40 mm Dipole Program is presented. The cable design parameters for the 50 mm Dipole Program are discussed, as well as portions of the SSC specification draft. Considerations leading to the final cable configuration and the results of preliminary trials are included. The first iteration of a strand mapping program to automate cable strand maps is introduced. 7 refs., 2 figs., 1 tab

  13. Documentation of scintigraphic examinations using miniature format colour films and an instant slide system

    International Nuclear Information System (INIS)

    Deininger, H.K.; Schmidt, C.

    1985-01-01

    A new 35 mm format instant film (Polachrome CS 135) was investigated for suitability in comparison to established conventional colour miniature films. Differences were found, depending on whether the photographic colour material was used for slides or paper prints. Optimum colour results were obtained in monitor photography. The material also proved useful for the recording of paper prints of colour scans, since these were mainly intended for the purpose of transferring the diagnostic findings as a complement to the written report. Priority was therefore given to the immediate availability of the copy, which may be of importance in monitor photography as well. In this respect the new polaroid instant miniature film is clearly superior to those 35 mm colour films that have been used in nuclear medicine up to now. (orig.) [de

  14. Macro stress mapping on thin film buckling

    Energy Technology Data Exchange (ETDEWEB)

    Goudeau, P.; Villain, P.; Renault, P.-O.; Tamura, N.; Celestre, R.S.; Padmore, H.A.

    2002-11-06

    Thin films deposited by Physical Vapour Deposition techniques on substrates generally exhibit large residual stresses which may be responsible of thin film buckling in the case of compressive stresses. Since the 80's, a lot of theoretical work has been done to develop mechanical models but only a few experimental work has been done on this subject to support these theoretical approaches and nothing concerning local stress measurement mainly because of the small dimension of the buckling (few 10th mm). This paper deals with the application of micro beam X-ray diffraction available on synchrotron radiation sources for stress mapping analysis of gold thin film buckling.

  15. Preparation and characterization of sponge film made from feathers

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yuan; Wu, Xiaoqian [College of Environmental Science and Engineering, Donghua University, Shanghai 201620 (China); Cao, Zhangjun [College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620 (China); Zhao, Xiaoxiang; Zhou, Meihua [College of Environmental Science and Engineering, Donghua University, Shanghai 201620 (China); Gao, Pin, E-mail: gaopin@mail.dhu.edu.cn [College of Environmental Science and Engineering, Donghua University, Shanghai 201620 (China)

    2013-12-01

    Feather wastes generated from poultry farms will pose a problem for disposal, but they are sustainable resources of keratin. Reduction is one of the commonly used methods to obtain soluble keratin from feather. However, the residues generated during feather reduction reaction were rarely investigated. In this study, the residues were transformed into a porous and flexible sponge film by freeze-drying without pretreatment or addition of cross-linking agents. Glycerol was used to alter the physical and chemical characteristics of the sponge film. The film was characterized with a fiber strong stretch instrument, a Fourier transform infrared spectrophotometer, scanning electron microscopy, an elemental analyzer, a differential scanning calorimeter and an automatic air permeability apparatus. Tensile strength and melting point of the sponge film with the optimum glycerol content were 6.2 MPa and 170 °C respectively. Due to air permeability of 368 mm/s, the film can potentially be used in medicine, biology, textile, environmental technology, and so on. It is ecologically friendly and will produce additional benefits from the renewable materials. The film was utilized as adsorbents to remove Cr(VI) from aqueous solutions and as a filtering material for air pollution. Its maximum Cr(VI) uptake capacity was about 148.8 mg/g and the removal rate of PM{sub 10} was 98.3%. - Graphical abstract: The reduction residues were made into a smooth, elastic, porous and flexible sponge film through freeze drying, no pretreatment and no cross-linking agent added. - Highlights: • The residue from feather waste reduction was turned into a sponge film. • A glycerol content of 5% produced a sponge with the optimum characteristics. • The sponge was uniform, stable up to 160 °C, and had an air permeability of 368 mm/s. • Feather-derived sponge film has potential applications in medicine and technology.

  16. Preparation and characterization of sponge film made from feathers

    International Nuclear Information System (INIS)

    Zhuang, Yuan; Wu, Xiaoqian; Cao, Zhangjun; Zhao, Xiaoxiang; Zhou, Meihua; Gao, Pin

    2013-01-01

    Feather wastes generated from poultry farms will pose a problem for disposal, but they are sustainable resources of keratin. Reduction is one of the commonly used methods to obtain soluble keratin from feather. However, the residues generated during feather reduction reaction were rarely investigated. In this study, the residues were transformed into a porous and flexible sponge film by freeze-drying without pretreatment or addition of cross-linking agents. Glycerol was used to alter the physical and chemical characteristics of the sponge film. The film was characterized with a fiber strong stretch instrument, a Fourier transform infrared spectrophotometer, scanning electron microscopy, an elemental analyzer, a differential scanning calorimeter and an automatic air permeability apparatus. Tensile strength and melting point of the sponge film with the optimum glycerol content were 6.2 MPa and 170 °C respectively. Due to air permeability of 368 mm/s, the film can potentially be used in medicine, biology, textile, environmental technology, and so on. It is ecologically friendly and will produce additional benefits from the renewable materials. The film was utilized as adsorbents to remove Cr(VI) from aqueous solutions and as a filtering material for air pollution. Its maximum Cr(VI) uptake capacity was about 148.8 mg/g and the removal rate of PM 10 was 98.3%. - Graphical abstract: The reduction residues were made into a smooth, elastic, porous and flexible sponge film through freeze drying, no pretreatment and no cross-linking agent added. - Highlights: • The residue from feather waste reduction was turned into a sponge film. • A glycerol content of 5% produced a sponge with the optimum characteristics. • The sponge was uniform, stable up to 160 °C, and had an air permeability of 368 mm/s. • Feather-derived sponge film has potential applications in medicine and technology

  17. Thin-film photovoltaic technology

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, R.N. [National Renewable Energy Laboratory, Golden, CO (United States)

    2010-07-01

    The high material and processing costs associated with single-crystal and polycrystalline silicon wafers that are commonly used in photovoltaic cells render these modules expensive. This presentation described thin-film solar cell technology as a promising alternative to silicon solar cell technology. Cadmium telluride (CdTe) thin films along with copper, indium, gallium, and selenium (CIGS) thin films have become the leaders in this field. Their large optical absorption coefficient can be attributed to a direct energy gap that allows the use of thin layers (1-2 {mu}m) of active material. The efficiency of thin-film solar cell devices based on CIGS is 20 per cent, compared to 16.7 per cent for thin-film solar cell devices based on CdTe. IBM recently reported an efficiency of 9.7 per cent for a new type of inorganic thin-film solar cell based on a Cu{sub 2}ZnSn(S, Se){sub 4} compound. The efficiency of an organic thin-film solar cell is 7.9 per cent. This presentation included a graph of PV device efficiencies and discussed technological advances in non-vacuum deposited, CIGS-based thin-film solar cells. 1 fig.

  18. Let's Make a Movie: Investigating Pre-Service Teachers' Reflections on Using Video Recorded Role Playing Cases in Turkey

    Science.gov (United States)

    Koc, Mustafa

    2011-01-01

    This study examined the potential consequences of using student-filmed video cases in the study of classroom management in teacher education. Pre-service teachers in groups were engaged in video-recorded role playing to simulate classroom memoirs. Each group shared their video cases and interpretations in a class presentation. Qualitative data…

  19. Ultraviolet photoelectron spectroscopy reveals energy-band dispersion for π-stacked 7,8,15,16-tetraazaterrylene thin films in a donor–acceptor bulk heterojunction

    Science.gov (United States)

    Aghdassi, Nabi; Wang, Qi; Ji, Ru-Ru; Wang, Bin; Fan, Jian; Duhm, Steffen

    2018-05-01

    7,8,15,16-tetraazaterrylene (TAT) thin films grown on highly oriented pyrolytic graphite (HOPG) substrates were studied extensively with regard to their intrinsic and interfacial electronic properties by means of ultraviolet photoelectron spectroscopy (UPS). Merely weak substrate–adsorbate interaction occurs at the TAT/HOPG interface, with interface energetics being only little affected by the nominal film thickness. Photon energy-dependent UPS performed perpendicular to the molecular planes of TAT multilayer films at room temperature clearly reveals band-like intermolecular dispersion of the TAT highest occupied molecular orbital (HOMO) energy. Based on a comparison with a tight-binding model, a relatively narrow bandwidth of 54 meV is derived, which points to the presence of an intermediate regime between hopping and band-like hole transport. Upon additional deposition of 2,2‧:5‧,2″:5″,2″‧-quaterthiophene (4T), a 4T:TAT donor–acceptor bulk heterojunction with a considerable HOMO-level offset at the donor–acceptor interface is formed. The 4T:TAT bulk heterojunction likewise exhibits intermolecular dispersion of the TAT HOMO energy, yet with a significant decreased bandwidth.

  20. Tc depression and superconductor-insulator transition in molybdenum nitride thin films

    Science.gov (United States)

    Ichikawa, F.; Makise, K.; Tsuneoka, T.; Maeda, S.; Shinozaki, B.

    2018-03-01

    We have studied that the Tc depression and the superconductor-insulator transition (SIT) in molybdenum nitride (MoN) thin films. Thin films were fabricated by reactive DC magnetron sputtering method onto (100) MgO substrates in the mixture of Ar and N2 gases. Several dozen MoN thin films were prepared in the range of 3 nm < thickness d < 60 nm. The resistance was measured by a DC four-probe technique. It is found that Tc decreases from 6.6 K for thick films with increase of the normal state sheet resistance {R}{{sq}}{{N}} and experimental data were fitted to the Finkel’stein formula using the bulk superconducting transition temperature Tc 0 = 6.45 K and the elastic scattering time of electron τ = 1.6 × 10‑16 s. From this analysis the critical sheet resistance Rc is found about 2 kΩ, which is smaller than the quantum sheet resistance R Q. This value of Rc is almost the same as those for 2D NbN films. The value of τ for MoN films is also the similar value for NbN films 1.0 × 10‑16 s, while Tc 0 is different from that for NbN films 14.85 K. It is indicated that the mechanism of SIT for MoN films is similar to that of NbN films, while the mean free path ℓ for MoN films is larger than that for NbN films.

  1. Analysis of aliasing artifacts in 16-slice helical CT

    International Nuclear Information System (INIS)

    Chen Wei; Liu Jingkang; Ou Xiaoguang; Li Wenzheng; Liao Weihua; Yan Ang

    2006-01-01

    Objective: To recognize the features of aliasing artifacts on CT images, and to investigate the effects of imaging parameters on the magnitude of this artifacts. Methods: An adult dry skull was placed in a plastic water-filled container and scanned with a PHILIPS 16-slice helical CT. All the acquired transaxial images by using several different acquisition or reconstruction parameters were examined for comparative assessment of the aliasing artifacts. Results: The aliasing artifacts could be seen in most instances and characterized as the spokewise patterns emanating from the edges of high contrast structure as its radius varies sharply in the longitudinal direction. The images that scanned with pitch of 0.3, 0.6 and 0.9, respectively, showed aliasing artifacts, and its severities increased with pitches escalated (detector combination 16 x 1.5, reconstruction thickness 2 mm); There were more significant aliasing artifacts on the images reconstructed with 0.8 mm slice width compared with 1-mm slice width, and no aliasing artifacts were observed on the images reconstructed with 2-mm slice width (detector combination 16 x 0.75, pitch 0.6); No artifacts were perceived on the images scanned with detector combination 16 x 0.75, while presented evidently with the use of detector combination 16 x 1.5 (pitch 0.6, reconstruction thickness 2 mm); The degrees of aliasing artifacts were unaltered when reconstruction interval and tube current changed. Conclusions: Aliasing artifacts are caused by undersampling. When the operator choose the thinner sampling thickness, lower pitch and a much wider reconstruction thickness judiciously, aliasing artifacts could be effectively mitigated or suppressed. (authors)

  2. Antibacterial activity of novel peptide derived from Cry1Ab16 toxin and development of LbL films for foodborne pathogens control

    International Nuclear Information System (INIS)

    Plácido, Alexandra; Bragança, Idalina; Marani, Mariela; Rodrigues de Araujo, Alyne; Vasconcelos, Andreanne Gomes; Batziou, Krystallenia; Domingues, Valentina F.

    2017-01-01

    Escherichia coli is one of the most common etiological agents of diarrhea in developing countries. The appearance of resistant E. coli prevents treatment of these infections. Biotechnological products incorporating antimicrobial peptides are currently being considered in applications to prevent intestinal infections by these bacteria. The aim of this study was to evaluate the antibacterial activity of the peptide PcL342-354C, which is derived from the toxin Cry1Ab16 from Bacillus thuringiensis, against E. coli strains. We also report the preparation, characterization and evaluation of the antibacterial activity of LbL films containing PcL342-354C. The results showed that the PcL342-354C peptide inhibited the growth of different strains of E. coli with minimal inhibitory concentration ranging from 15.62–31.25 μg/mL and minimal bactericidal concentration was 250 μg/mL, indicating a potential antibacterial activity. The morphology of an ITO/Cashew gum/PcL342-354C film was analysed using atomic force microscopy which showed an increase of roughness due to the increase in the number of layers. The LbL films showed significant antibacterial activity against E. coli NCTC 9001 in both conditions tested (10 and 20 bilayers). Our results indicate that the peptide exhibits an antibacterial potential that can be tapped to develop biomaterials with antibacterial activity for use against foodborne pathogens. - Highlights: • The PcL342–354C peptide inhibited the growth of E. coli. • The peptide can be simply incorporated into edible films combined with cashew gum. • LbL films incorporating the peptide have antibacterial activity against E. coli. • The PcL342–354C exhibits an antibacterial potential that can be tapped to develop biomaterials.

  3. Antibacterial activity of novel peptide derived from Cry1Ab16 toxin and development of LbL films for foodborne pathogens control

    Energy Technology Data Exchange (ETDEWEB)

    Plácido, Alexandra, E-mail: alexandra.placido@gmail.com [REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, ISEP, Instituto Politécnico do Porto, Porto (Portugal); Bragança, Idalina, E-mail: linab_20@hotmail.com [REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, ISEP, Instituto Politécnico do Porto, Porto (Portugal); Marani, Mariela, E-mail: mmarani@cenpat-conicet.gob.ar [IPEEC-CONICET, Consejo Nacional de Investigaciones Científicas y Técnicas, Puerto Madryn, Chubut (Argentina); Rodrigues de Araujo, Alyne, E-mail: alyne_biomed@hotmail.com [Núcleo de Pesquisa em Biodiversidade e Biotecnologia, BIOTEC, Campus Ministro Reis Velloso, CMRV, Universidade Federal do Piauí, UFPI, Parnaíba, PI (Brazil); Vasconcelos, Andreanne Gomes, E-mail: andreannegv@gmail.com [Núcleo de Pesquisa em Biodiversidade e Biotecnologia, BIOTEC, Campus Ministro Reis Velloso, CMRV, Universidade Federal do Piauí, UFPI, Parnaíba, PI (Brazil); Batziou, Krystallenia, E-mail: batkrysta@gmail.com [REQUIMTE/UCIBIO, Departamento de Química e Bioquímica, Faculdade de Ciências da Universidade do Porto, Porto (Portugal); Domingues, Valentina F., E-mail: vfd@isep.ipp.pt [REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, ISEP, Instituto Politécnico do Porto, Porto (Portugal); and others

    2017-06-01

    Escherichia coli is one of the most common etiological agents of diarrhea in developing countries. The appearance of resistant E. coli prevents treatment of these infections. Biotechnological products incorporating antimicrobial peptides are currently being considered in applications to prevent intestinal infections by these bacteria. The aim of this study was to evaluate the antibacterial activity of the peptide PcL342-354C, which is derived from the toxin Cry1Ab16 from Bacillus thuringiensis, against E. coli strains. We also report the preparation, characterization and evaluation of the antibacterial activity of LbL films containing PcL342-354C. The results showed that the PcL342-354C peptide inhibited the growth of different strains of E. coli with minimal inhibitory concentration ranging from 15.62–31.25 μg/mL and minimal bactericidal concentration was 250 μg/mL, indicating a potential antibacterial activity. The morphology of an ITO/Cashew gum/PcL342-354C film was analysed using atomic force microscopy which showed an increase of roughness due to the increase in the number of layers. The LbL films showed significant antibacterial activity against E. coli NCTC 9001 in both conditions tested (10 and 20 bilayers). Our results indicate that the peptide exhibits an antibacterial potential that can be tapped to develop biomaterials with antibacterial activity for use against foodborne pathogens. - Highlights: • The PcL342–354C peptide inhibited the growth of E. coli. • The peptide can be simply incorporated into edible films combined with cashew gum. • LbL films incorporating the peptide have antibacterial activity against E. coli. • The PcL342–354C exhibits an antibacterial potential that can be tapped to develop biomaterials.

  4. PEMBUATAN DAN KARAKTERISASI ANTIMICROBIAL FILM DARI PATI SINGKONG DAN EKSTRAK KEDELAI SEBAGAI BAHAN PENGEMAS MAKANAN

    Directory of Open Access Journals (Sweden)

    Shobirotu Salamah

    2015-02-01

    Full Text Available Salah satu upaya yang dilakukan untuk mengatasi pencemaran lingkungan oleh bahan pengemas plastik adalah dengan pengembangan biodegradable plastic ramah lingkungan. Oleh karena itu dibutuhkan produk kemasan makanan yang dapat diuraikan. Salah satunya adalah memberi antimikroba pada edible film. Antimicrobial film tersebut diuji karakterisasinya secara fisik dan mekanik menggunakan alat FS/SPAG 01/2650 dan diuji efektifitas antimikrobanya. Didapat kadar air tertinggi pada edible film kontrol yaitu 15,83 %. Densitas dengan penambahan ekstrak kayu manis 1,5% memiliki nilai yang lebih tertinggi yaitu 1,1 gr/ml. Nilai Modulus young atau tingkat elastisitas film tertinggi yaitu pada edible film penambahan ekstrak bawang putih 1% sebesar 2,872 Mpa. Nilai Tensile strength atau nilai kuat tarik suatu film tertinggi yaitu 3,808 N/mm diperoleh pada penambahan ekstrak kayu manis 1,5% dan Nilai Extention at Maximum atau nilai pemanjangan film tertinggi yaitu 6,880 mm pada penambahan ekstrak kayu manis 1,5%. Sedangkan pengujian daya hambat terhadap Escherichia coli dilakukan menggunakan metode sumuran. Diameter zona bening terbesar yaitu pada penambahan ekstrak bawang putih 1,5%.

  5. SU-G-201-12: Investigation of Beta-Emitter 90Sr-90Y Dose Distribution Using Gafchromic EBT3 Film for Application On Conformal Skin Brachytherapy Device

    International Nuclear Information System (INIS)

    Ferreira, C; Johnson, D; Ahmad, S; Rasmussen, K; Jung, J

    2016-01-01

    Purpose: To investigate 90 Sr- 90 Y as a high dose rate (HDR) source for application in a conformal skin brachytherapy (CSBT) device. The CSBT device has been previously developed to provide patient specific treatment for small inoperable lesions and irregular surfaces. Methods: A popular beta emitter, 90 Sr- 90 Y was tested for feasibility in a CSBT device. A 1 cm diameter plaque was used to deliver dose to a solid water phantom containing EBT3 Gafchromic films arranged at the surface and perpendicular to it. Additionally, a 1 cm diameter 6 MeV electron beam was used to irradiate EBT3 film at 100 cm SSD with a 0.5 cm bolus. Films were digitized with an Epson Expression 10000 XL scanner and calibrated with a 6 MeV electron specific dose curve. Normalized percent depth doses (PDD) and dose profiles for both techniques were analyzed using ImageJ. Results: Dose distributions achieved with the 90 Sr- 90 Y sources were compared with those of external electron beam radiation therapy (EBRT). Penumbra (20%- 80%) for EBRT and 90Sr-90Y were 4.3 mm and 1.6 mm, respectively. PDD values of 50% (normalized to 2 mm) were 10.1 mm and 2.8 mm for electron and 90 Sr- 90 Y, respectively. Flatness (80% of the central beam profile) was 14.1% at a 5 mm depth for EBRT and 4.0% at surface for the 90 Sr- 90 Y. Conclusion: As expected, the PDDs of 90 Sr- 90 Y in water are shallower than that of external electron beams for the same field size. 90 Sr- 90 Y can be used in CSBT to provide patient specific treatment where shallower depth doses than that provided by electron external beams may be required: e.g. eyelids, nose, lips, ears, etc. The customizability of EBRT could be replicated by using multiple adjacent 90 Sr- 90 Y plaque placements.

  6. SU-G-201-12: Investigation of Beta-Emitter 90Sr-90Y Dose Distribution Using Gafchromic EBT3 Film for Application On Conformal Skin Brachytherapy Device

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, C; Johnson, D; Ahmad, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Rasmussen, K [University of Texas HSC SA, San Antonio, TX (United States); Jung, J [East Carolina University Greenville, NC (United States)

    2016-06-15

    Purpose: To investigate {sup 90}Sr-{sup 90}Y as a high dose rate (HDR) source for application in a conformal skin brachytherapy (CSBT) device. The CSBT device has been previously developed to provide patient specific treatment for small inoperable lesions and irregular surfaces. Methods: A popular beta emitter, {sup 90}Sr-{sup 90}Y was tested for feasibility in a CSBT device. A 1 cm diameter plaque was used to deliver dose to a solid water phantom containing EBT3 Gafchromic films arranged at the surface and perpendicular to it. Additionally, a 1 cm diameter 6 MeV electron beam was used to irradiate EBT3 film at 100 cm SSD with a 0.5 cm bolus. Films were digitized with an Epson Expression 10000 XL scanner and calibrated with a 6 MeV electron specific dose curve. Normalized percent depth doses (PDD) and dose profiles for both techniques were analyzed using ImageJ. Results: Dose distributions achieved with the {sup 90}Sr-{sup 90}Y sources were compared with those of external electron beam radiation therapy (EBRT). Penumbra (20%- 80%) for EBRT and 90Sr-90Y were 4.3 mm and 1.6 mm, respectively. PDD values of 50% (normalized to 2 mm) were 10.1 mm and 2.8 mm for electron and {sup 90}Sr-{sup 90}Y, respectively. Flatness (80% of the central beam profile) was 14.1% at a 5 mm depth for EBRT and 4.0% at surface for the {sup 90}Sr-{sup 90}Y. Conclusion: As expected, the PDDs of {sup 90}Sr-{sup 90}Y in water are shallower than that of external electron beams for the same field size. {sup 90}Sr-{sup 90}Y can be used in CSBT to provide patient specific treatment where shallower depth doses than that provided by electron external beams may be required: e.g. eyelids, nose, lips, ears, etc. The customizability of EBRT could be replicated by using multiple adjacent {sup 90}Sr-{sup 90}Y plaque placements.

  7. Características físicas de filmes biodegradáveis produzidos a partir de amidos modificados de mandioca Physical characteristics of cassava modified starch films

    Directory of Open Access Journals (Sweden)

    Celina Maria Henrique

    2008-03-01

    Full Text Available Amidos de mandioca podem ser matérias-primas para a obtenção de filmes biodegradáveis, sendo que para a formação destes é necessária a elaboração de suspensões filmogênicas. Alguns processos de modificação do amido podem torná-lo miscível em água fria, e outros processos de modificação podem alterar as propriedades dos filmes, tornando-os mais fortes e flexíveis. O objetivo deste trabalho foi verificar as características físicas de filmes biodegradáveis elaborados com amidos modificados de mandioca pelo processo de casting (desidratação de uma solução filmogênica sobre placas de Petri. Os amidos modificados utilizados foram: cross linked; carboximetilamido (CMA de baixa viscosidade e alta viscosidade e esterificado. A viscosidade é fator importante para a elaboração da suspensão filmogênica e foi avaliada utilizando-se o equipamento Rapid Visco Analyser (RVA. Os filmes elaborados foram comparados a um filme de PVC comercial com espessura de 0,0208 a 0,0217 mm. Os amidos foram caracterizados por avaliação da composição físico-química, granulometria, microscopia eletrônica e viscosidade (Rapid Visco Analyser. A análise por microscopia eletrônica dos filmes ressaltou as diferenças entre os diferentes amidos utilizados. O RVA mostrou que, com exceção do cross linked, todos os amidos modificados apresentaram certa solubilidade a frio, o que facilita o preparo das soluções filmogênicas, entretanto, todos os amidos modificados apresentaram redução acentuada da tendência à retrogradação, propriedade geralmente associada à formação de filmes. As espessuras dos filmes de amido variaram de 0,0551 a 0,1279 mm, cujas espessuras mínimas foram a dos filmes de amido cross linked. Os filmes mostraram-se transparentes, manuseáveis e bem homogêneos. Não houve interferência da espessura na permeabilidade ao vapor d'água, e os filmes com 5% de matéria-seca, independente do tipo de amido modificado

  8. Investigation of liquid film behavior at the onset of flooding during adiabatic counter-current air-water two-phase flow in an inclined pipe

    International Nuclear Information System (INIS)

    Deendarlianto; Ousaka, Akiharu; Kariyasaki, Akira; Fukano, Tohru

    2005-01-01

    The liquid film characteristics at the onset of flooding in an inclined pipe (16 mm i.d. and 2.2 m in length) have been investigated experimentally. A constant electric current method and visual observation were utilized to elucidate the flow mechanisms at the onset of flooding. Two mechanisms are clarified to control the flooding in lower flooding and upper flooding, respectively. The lower flooding occurred at lower liquid flow rate and high pipe inclination angle. In this mechanism, the liquid film does not block the pipe cross-section. On the other hand, the upper flooding occurred at higher liquid flow rate and low pipe inclination angle. In this case, blocking of the pipe cross-section by large wave and entrainment plays an important role. The experimental data indicated that there was no reversal motion of liquid film at the onset of flooding during the operation of both lower flooding and upper flooding. The effects of pipe inclination angle on the onset of flooding are also discussed

  9. Sporadic Creutzfeldt-Jakob Disease MM1+2C and MM1 are Identical in Transmission Properties.

    Science.gov (United States)

    Kobayashi, Atsushi; Matsuura, Yuichi; Iwaki, Toru; Iwasaki, Yasushi; Yoshida, Mari; Takahashi, Hitoshi; Murayama, Shigeo; Takao, Masaki; Kato, Shinsuke; Yamada, Masahito; Mohri, Shirou; Kitamoto, Tetsuyuki

    2016-01-01

    The genotype (methionine, M or valine, V) at polymorphic codon 129 of the PRNP gene and the type (1 or 2) of abnormal prion protein in the brain are the major determinants of the clinicopathological features of sporadic Creutzfeldt-Jakob disease (CJD), thus providing molecular basis for classification of sporadic CJD, that is, MM1, MM2, MV1, MV2, VV1 or VV2. In addition to these "pure" cases, "mixed" cases presenting mixed neuropathological and biochemical features have also been recognized. The most frequently observed mixed form is the co-occurrence of MM1 and MM2, namely MM1+2. However, it has remained elusive whether MM1+2 could be a causative origin of dura mater graft-associated CJD (dCJD), one of the largest subgroups of iatrogenic CJD. To test this possibility, we performed transmission experiments of MM1+2 prions and a systematic neuropathological examination of dCJD patients in the present study. The transmission properties of the MM1+2 prions were identical to those of MM1 prions because MM2 prions lacked transmissibility. In addition, the neuropathological characteristics of MM2 were totally absent in dCJD patients examined. These results suggest that MM1+2 can be a causative origin of dCJD and causes neuropathological phenotype similar to that of MM1. © 2015 International Society of Neuropathology.

  10. CT-based postimplant dosimetry of prostate brachytherapy. Comparison of 1-mm and 5-mm section CT

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Kanematsu, Masayuki; Matsuo, Masayuki; Hoshi, Hiroaki; Nakano, Masahiro; Maeda, Sanaho; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V 100 (percent of the prostate volume receiving at least the full prescribed dose), and prostate D 90 (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. The mean ±1 standard deviation (SD) postimplant pVol was 20.17±6.66 cc by 1-mm section CT and 22.24±8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P 100 was 80.44%±7.06% by 1-mm section CT and 77.33%±10.22% by 5-mm section CT. The mean postimplant prostate D 90 was 83.28%±10.81% by 1-mm section CT and 78.60%±15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility. (author)

  11. Nitinol: Tubing versus sputtered film - microcleanliness and corrosion behavior.

    Science.gov (United States)

    Wohlschlögel, Markus; Lima de Miranda, Rodrigo; Schüßler, Andreas; Quandt, Eckhard

    2016-08-01

    Corrosion behavior and microcleanliness of medical-device grade Nitinol tubing (Nix Ti1- x , x = 0.51; outer diameter 7 mm, wall thickness 0.5 mm), drawn from various ingot qualities, are compared to the characteristics of sputtered Nitinol film material (Nix Ti1- x , x = 0.51; thickness 50 µm). Electropolished tubing half-shell samples are tested versus as-received sputtered film samples. Inclusion size distributions are assessed using quantitative metallography and corrosion behavior is investigated by potentiodynamic polarization testing in phosphate-buffered saline at body temperature. For the sputtered film samples, the surface chemistry is additionally analyzed employing Auger Electron Spectroscopy (AES) composition-depth profiling. Results show that the fraction of breakdowns in the potentiodynamic polarization test correlates with number and size of the inclusions in the material. For the sputtered Nitinol film material no inclusions were detectable by light microscopy on the one hand and no breakdowns were found in the potentiodynamic polarization test on the other hand. As for electropolished Nitinol, the sputtered Nitinol film material reveals Nickel depletion and an Oxygen-to-Titanium intensity ratio of ∼2:1 in the surface oxide layer, as measured by AES. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1176-1181, 2016. © 2015 Wiley Periodicals, Inc.

  12. SU-E-T-286: Dose Verification of Spot-Scanning Proton Beam Using GafChromic EBT3 Film

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C; Tang, S; Mah, D [ProCure Proton Therapy Center, Somerset, NJ (United States); Chan, M [Memorial Sloan-Kettering Cancer Center, Basking Ridge, NJ (United States)

    2015-06-15

    Purpose: Dose verification of spot-scanning proton pencil beam is performed via planar dose measurements at several depths using an ionization-chamber array, requiring repeat irradiations of each field for each depth. Here we investigate film dosimetry which has two advantages: higher resolution and efficiency from one-shot irradiation for multiple depths. Methods: Film calibration was performed using an EBT3 film at 20-cm depth of Plastic Water (CIRS, Norfolk, VA) exposed by a 10-level step wedge on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged from 25–250 cGy(RBE) for proton energies of 170–200 MeV. A uniform 1000 cm{sup 3} dose cube and a clinical prostate combined with seminal-vesicle and pelvic-nodes plan were used for this study. All treatment plans were generated in the RayStation (RaySearch Lab, Sweden). The planar doses at different depths for both cases were measured with film using triple-channel dosimetry and the MatriXX PT (IBA Dosimetry, Germany). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film and MatriXX, versus treatment planning system (TPS) calculations were analyzed and compared using the FilmQA Pro (Ashland Inc., Bridgewater, NJ). Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate >95% for 2%/2mm and are comparable with the MatriXX measurements (0.7%, 1.8%, 3.8% mean differences corresponding to 3%/3mm, 3%/2mm, 2%/2mm, respectively). Overall passing rates for EBT3 films appear higher than those with MatriXX detectors. Conclusion: The energy dependence of the film response could be minimized by calibration using proton beam with mixed energies. The greater efficiency of the dose verification using GafChromic EBT3 results in a potential cost trade-off between room capacity and film cost. EBT3 film may offer distinct advantages in highly intensity-modulated fields due to its higher resolution

  13. Minerals deposited as thin films

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Leyt, D.V. de; Custo, Graciela

    1987-01-01

    Free matrix effects are due to thin film deposits. Thus, it was decided to investigate this technique as a possibility to use pure oxide of the desired element, extrapolating its concentration from analytical curves made with avoiding, at the same time, mathematical corrections. The proposed method was employed to determine iron and titanium concentrations in geological samples. The range studied was 0.1-5%m/m for titanium and 5-20%m/m for iron. For both elements the reproducibility was about 7% and differences between this method and other chemical determinations were 15% for titanium and 7% for iron. (Author) [es

  14. Microstructure and opto-electric properties of Cu/ITO thin films

    International Nuclear Information System (INIS)

    Wang Xian; Li Junlei; Shi Shiwei; Song Xueping; Cui Jingbiao; Sun Zhaoqi

    2012-01-01

    Highlights: ► We prepared Cu/ITO films with different Cu layer thickness. ► We analyzed the relation between opto-electric properties and roughness of the films. ► The Cu-16.1 nm/ITO film shows excellent optical and electric properties. ► Cu/ITO films have great application prospects in new-type transflective displays. - Abstract: Cu/ITO thin films were deposited on glass and silicon substrates by DC and RF magnetron sputtering at room temperature. X-ray diffraction results showed that the films were amorphous. Both of SEM images and 3D Profilometer images indicated that the surface morphology of the ITO films had been affected by the Cu layer. The optical and electric properties of the Cu/ITO films changed significantly with the variation of Cu layer thickness. Cu-5.4 nm/ITO film exhibited the highest optical transmittance of 62.9% at 550 nm and the lowest sheet resistance of 96 Ω/□, whereas Cu-16.1 nm/ITO film showed the highest average reflectance of 24.0% and the lowest resistance of 27.4 Ω/□. Based on our analysis, it was evaluated that Cu layer had an important effect on the electrical and optical properties of ITO thin films.

  15. Technical Note: Initial characterization of the new EBT-XD Gafchromic film

    Energy Technology Data Exchange (ETDEWEB)

    Grams, Michael P., E-mail: grams.michael@mayo.edu; Gustafson, Jon M.; Long, Kenneth M.; Fong de los Santos, Luis E. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-10-15

    Purpose: To assess the dosimetric accuracy and energy dependence of the new EBT-eXtended Dose (XD) Gafchromic film and to compare the lateral response artifact (LRA) between EBT-XD and EBT3 film. Methods: EBT3 and EBT-XD calibration curves were created by exposing films to known doses from 0 to 3000 cGy using a 6 MV beam. To assess the accuracy and dynamic range of EBT-XD, a 60° enhanced dynamic wedge (EDW) was used to deliver a dose range of approximately 200–2900 cGy. Comparison to treatment planning system (TPS) calculation was made using a gamma analysis with 2%/2 mm passing criteria. To assess and compare the LRA between EBT3 and EBT-XD, 21 × 21 cm{sup 2} open fields delivered doses of 1000, 2000, and 3000 cGy to both types of film. Films were placed at the center of the scanner, and ratios of measured to TPS predicted doses were calculated at 50 and 80 mm lateral from the scanner center in order to quantitatively assess the LRA. To evaluate the energy dependence of EBT-XD film, seven known doses ranging from 400 to 3000 cGy were delivered using both 6 and 18 MV beams and the resulting optical densities (ODs) compared. Results: The gamma passing rate was 99.1% for the 6 MV EDW delivery. EBT-XD film exhibited minimal LRA (<1%) up to 3000 cGy. In contrast, EBT3 demonstrated an under-response of 11.3% and 22.7% at lateral positions of 50 and 80 mm, respectively, for the 3000 cGy exposure. Differences between ODs of the EBT-XD films exposed to known doses from 6 to 18 MV beams were <0.8% suggesting minimal energy dependence throughout this energy range. Conclusions: The LRA of EBT-XD is greatly reduced when compared to EBT3. This in combination with its accuracy from 0 to 3000 cGy and minimal energy dependence from 6 to 18 MV makes EBT-XD film well suited for dosimetric measurements in high dose SRS/SBRT applications.

  16. Technical Note: Initial characterization of the new EBT-XD Gafchromic film

    International Nuclear Information System (INIS)

    Grams, Michael P.; Gustafson, Jon M.; Long, Kenneth M.; Fong de los Santos, Luis E.

    2015-01-01

    Purpose: To assess the dosimetric accuracy and energy dependence of the new EBT-eXtended Dose (XD) Gafchromic film and to compare the lateral response artifact (LRA) between EBT-XD and EBT3 film. Methods: EBT3 and EBT-XD calibration curves were created by exposing films to known doses from 0 to 3000 cGy using a 6 MV beam. To assess the accuracy and dynamic range of EBT-XD, a 60° enhanced dynamic wedge (EDW) was used to deliver a dose range of approximately 200–2900 cGy. Comparison to treatment planning system (TPS) calculation was made using a gamma analysis with 2%/2 mm passing criteria. To assess and compare the LRA between EBT3 and EBT-XD, 21 × 21 cm 2 open fields delivered doses of 1000, 2000, and 3000 cGy to both types of film. Films were placed at the center of the scanner, and ratios of measured to TPS predicted doses were calculated at 50 and 80 mm lateral from the scanner center in order to quantitatively assess the LRA. To evaluate the energy dependence of EBT-XD film, seven known doses ranging from 400 to 3000 cGy were delivered using both 6 and 18 MV beams and the resulting optical densities (ODs) compared. Results: The gamma passing rate was 99.1% for the 6 MV EDW delivery. EBT-XD film exhibited minimal LRA (<1%) up to 3000 cGy. In contrast, EBT3 demonstrated an under-response of 11.3% and 22.7% at lateral positions of 50 and 80 mm, respectively, for the 3000 cGy exposure. Differences between ODs of the EBT-XD films exposed to known doses from 6 to 18 MV beams were <0.8% suggesting minimal energy dependence throughout this energy range. Conclusions: The LRA of EBT-XD is greatly reduced when compared to EBT3. This in combination with its accuracy from 0 to 3000 cGy and minimal energy dependence from 6 to 18 MV makes EBT-XD film well suited for dosimetric measurements in high dose SRS/SBRT applications

  17. ALMA Discovery of Solar Umbral Brightness Enhancement at λ = 3 mm

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, Kazumasa [Institute for Space-Earth Environmental Research, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8601 (Japan); Loukitcheva, Maria [Center for Solar-Terrestrial Research, New Jersey Institute of Technology, 323 Martin Luther King Boulevard, Newark, NJ 07102 (United States); Shimojo, Masumi [Chile Observatory, National Astronomical Observatory of Japan, Mitaka, Tokyo 181-8588 (Japan); Solanki, Sami K. [Max Planck Institute for Solar System Research, Justus-von-Liebig-Weg 3, D-37073 Göttingen (Germany); White, Stephen M., E-mail: k.iwai@isee.nagoya-u.ac.jp [Space Vehicles Directorate, Air Force Research Laboratory, Albuquerque, NM (United States)

    2017-06-01

    We report the discovery of a brightness enhancement in the center of a large sunspot umbra at a wavelength of 3 mm using the Atacama Large Millimeter/sub-millimeter Array (ALMA). Sunspots are among the most prominent features on the solar surface, but many of their aspects are surprisingly poorly understood. We analyzed a λ = 3 mm (100 GHz) mosaic image obtained by ALMA that includes a large sunspot within the active region AR12470, on 2015 December 16. The 3 mm map has a 300″ × 300″ field of view and 4.″9 × 2.″2 spatial resolution, which is the highest spatial resolution map of an entire sunspot in this frequency range. We find a gradient of 3 mm brightness from a high value in the outer penumbra to a low value in the inner penumbra/outer umbra. Within the inner umbra, there is a marked increase in 3 mm brightness temperature, which we call an umbral brightness enhancement. This enhanced emission corresponds to a temperature excess of 800 K relative to the surrounding inner penumbral region and coincides with excess brightness in the 1330 and 1400 Å slit-jaw images of the Interface Region Imaging Spectrograph ( IRIS ), adjacent to a partial lightbridge. This λ = 3 mm brightness enhancement may be an intrinsic feature of the sunspot umbra at chromospheric heights, such as a manifestation of umbral flashes, or it could be related to a coronal plume, since the brightness enhancement was coincident with the footpoint of a coronal loop observed at 171 Å.

  18. Calculation of viscoelastic properties of edible films: application of three models

    Directory of Open Access Journals (Sweden)

    CHANDRA Prabir K.

    2000-01-01

    Full Text Available The viscoelastic properties of edible films can provide information at the structural level of the biopolymers used. The objective of this work was to test three simple models of linear viscoelastic theory (Maxwell, Generalized Maxwell with two units in parallel, and Burgers using the results of stress relaxation tests in edible films of myofibrillar proteins of Nile Tilapia. The films were elaborated according to a casting technique and pre-conditioned at 58% relative humidity and 22ºC for 4 days. The testing sample (15mm x 118mm was submitted to tests of stress relaxation in an equipment of physical measurements, TA.XT2i. The deformation, imposed to the sample, was 1%, guaranteeing the permanency in the domain of the linear viscoelasticity. The models were fitted to experimental data (stress x time by nonlinear regression. The Generalized Maxwell model with two units in parallel and the Burgers model represented the relaxation curves of stress satisfactorily. The viscoelastic properties varied in a way that they were less dependent on the thickness of the films.

  19. GOX-functionalized nanodiamond films for electrochemical biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Villalba, Pedro [Department of Chemical and Biomedical Engineering, University of South Florida (United States); Departamento de Medicina, Universidad del Norte, Barranquilla (Colombia); Ram, Manoj K., E-mail: mkram@usf.edu [Department of Mechanical Engineering, University of South Florida, 4202 E Fowler Avenue, Tampa, FL, 33620-5350 (United States); Nanotechnology Research and Education Center, University of South Florida (United States); Gomez, Humberto [Department of Mechanical Engineering, University of South Florida, 4202 E Fowler Avenue, Tampa, FL, 33620-5350 (United States); Departamento de Medicina, Universidad del Norte, Barranquilla (Colombia); Kumar, Amrita [Department of Physiology, Emory University. Atlanta GA (United States); Bhethanabotla, Venkat [Department of Chemical and Biomedical Engineering, University of South Florida (United States); Kumar, Ashok [Department of Mechanical Engineering, University of South Florida, 4202 E Fowler Avenue, Tampa, FL, 33620-5350 (United States); Nanotechnology Research and Education Center, University of South Florida (United States)

    2011-07-20

    The importance of nanodiamond in biological and technological applications has been recognized recently, and applied in drug delivery, biochip, sensors and biosensors. Under this investigation, nanodiamond (ND) and nitrogen doped nanodiamond (NND) were deposited on n-type silicon films, and later functionalized with enzyme Glucose oxidase (GOX). The GOX functionalized doped and undoped ND films were characterized using combination of several techniques; i.e. FTIR spectroscopy, Raman spectroscopy, atomic force microscopy (AFM) and electrochemical techniques. ND/GOX and NND/GOX thin films on n-type silicon have been found to provide sensitive glucose sensor. GOX has been chosen as a model enzyme system to functionalize with ND at molecular level to understand the glucose biosensor. - Research highlights: {yields} Nanodiamond (ND) films were used as an enzyme electrode for glucose quantification. {yields} Electrochemical behavior of doped and intrinsic films was analyzed. {yields} Electrode demonstrates sensitivity to glucose concentration in dynamic condition. {yields} Linear behavior was observed upto 8mM before saturation condition.

  20. GOX-functionalized nanodiamond films for electrochemical biosensor

    International Nuclear Information System (INIS)

    Villalba, Pedro; Ram, Manoj K.; Gomez, Humberto; Kumar, Amrita; Bhethanabotla, Venkat; Kumar, Ashok

    2011-01-01

    The importance of nanodiamond in biological and technological applications has been recognized recently, and applied in drug delivery, biochip, sensors and biosensors. Under this investigation, nanodiamond (ND) and nitrogen doped nanodiamond (NND) were deposited on n-type silicon films, and later functionalized with enzyme Glucose oxidase (GOX). The GOX functionalized doped and undoped ND films were characterized using combination of several techniques; i.e. FTIR spectroscopy, Raman spectroscopy, atomic force microscopy (AFM) and electrochemical techniques. ND/GOX and NND/GOX thin films on n-type silicon have been found to provide sensitive glucose sensor. GOX has been chosen as a model enzyme system to functionalize with ND at molecular level to understand the glucose biosensor. - Research highlights: → Nanodiamond (ND) films were used as an enzyme electrode for glucose quantification. → Electrochemical behavior of doped and intrinsic films was analyzed. → Electrode demonstrates sensitivity to glucose concentration in dynamic condition. → Linear behavior was observed upto 8mM before saturation condition.

  1. Patient specific quality assurance of IMRT: quantitative approach using film dosimetry and optimization

    International Nuclear Information System (INIS)

    Shin, Kyung Hwan; Park, Sung Yong; Park, Dong Hyun

    2005-01-01

    Film dosimetry an a part of patient specific intensity modulated radiation therapy quality assurance (IMRT QA) was performed to develop a new optimization method of film isocenter offset and to then suggest new quantitative criteria for film dosimetry. Film dosimetry was performed on 14 IMRT patients with head and neck cancers. An optimization method for obtaining the local minimum was developed to adjust for the error in the film isocenter offset, which is the largest part of the systemic errors. The adjust value of the film isocenter offset under optimization was 1 mm in 12 patients, while only two patients showed 2 mm translation. The means of absolute average dose difference before and after optimization were 2.36 and 1.56%, respectively, and the mean radios over a 5% tolerance were 9.67 and 2.88%. After optimization, the differences in the dose decreased dramatically. A low dose range cutoff (L-Cutoff) had been suggested for clinical application. New quantitative criteria of a ratio of over a 5%, but less than 10% tolerance, and for an absolute average dose difference less than 3% have been suggested for the verification of film dosimetry. The new optimization method was effective in adjusting for the film dosimetry error, and the newly quantitative criteria suggested in this research are believed to be sufficiently accurate and clinically useful

  2. Application of heat treatment and dispersive strengthening concept in interlayer deposition to enhance diamond film adherence

    Energy Technology Data Exchange (ETDEWEB)

    Lin Chiiruey [Tatung Inst. of Technol., Taipei (Taiwan, Province of China). Dept. of Mech. Eng.; Kuo Chengtzu; Chang Rueyming [Institute of Materials Science and Engineering, National Chiao Tung University, 1001 Ta-Hsueh Road, Hsinchu 30050 (Taiwan, Province of China)

    1997-10-31

    Two different deposition processes were carried out to enhance adherence of diamond films on WC+3-5%Co substrate with Ti-Si as the interlayer. One process can be called two-step diamond deposition process. Another process can be called interlayer heat treatment process. Diamond films were deposited by a microwave plasma chemical vapor deposition system. Ti and Si interlayer are deposited by DC sputter and an E-gun, respectively. Film morphologies, interface structure and film quality were examined by SEM, XRD, Auger electron spectroscopy and Raman spectroscopy. The residual stresses and adhesion strengths of the films were determined by Raman spectroscopy and indentation adhesion testing, respectively. Comparing the regular one-step diamond deposition process with the present two different new processes, the average dP/dX values, which are a measure of the adherence of the film, are 354 kgf/mm, 494 kgf/mm and 787 kgf/mm, respectively. In other words, the interlayer heat treatment process gives the best film adherence on average. For the two-step diamond deposition process, the interlayer thickness and the percent diamond surface coverage of the first diamond deposition step are the main parameters, and there exists an optimum Ti thickness and percent diamond coverage for the best film adherence. The main contribution to better film adherence is not a large difference in residual stress, but is due to the following reasons. The interlayer heat treatment can transform amorphous Si to polycrystalline Si, and may form strong TiC and SiC bonding. The polycrystalline Si and the diamond particles from the first diamond deposition step can be an effective seeds to enhance diamond nucleation. (orig.) 11 refs.

  3. A 240-channel thick film multi-chip module for readout of silicon drift detectors

    International Nuclear Information System (INIS)

    Lynn, D.; Bellwied, R.; Beuttenmueller, R.; Caines, H.; Chen, W.; DiMassimo, D.; Dyke, H.; Elliott, D.; Grau, M.; Hoffmann, G.W.; Humanic, T.; Jensen, P.; Kleinfelder, S.A.; Kotov, I.; Kraner, H.W.; Kuczewski, P.; Leonhardt, B.; Li, Z.; Liaw, C.J.; LoCurto, G.; Middelkamp, P.; Minor, R.; Mazeh, N.; Nehmeh, S.; O'Conner, P.; Ott, G.; Pandey, S.U.; Pruneau, C.; Pinelli, D.; Radeka, V.; Rescia, S.; Rykov, V.; Schambach, J.; Sedlmeir, J.; Sheen, J.; Soja, B.; Stephani, D.; Sugarbaker, E.; Takahashi, J.; Wilson, K.

    2000-01-01

    We have developed a thick film multi-chip module for readout of silicon drift (or low capacitance ∼200 fF) detectors. Main elements of the module include a custom 16-channel NPN-BJT preamplifier-shaper (PASA) and a custom 16-channel CMOS Switched Capacitor Array (SCA). The primary design criteria of the module were the minimizations of the power (12 mW/channel), noise (ENC=490 e - rms), size (20.5 mmx63 mm), and radiation length (1.4%). We will discuss various aspects of the PASA design, with emphasis on the preamplifier feedback network. The SCA is a modification of an integrated circuit that has been previously described [1]; its design features specific to its application in the SVT (Silicon Vertex Tracker in the STAR experiment at RHIC) will be discussed. The 240-channel multi-chip module is a circuit with five metal layers fabricated in thick film technology on a beryllia substrate and contains 35 custom and commercial integrated circuits. It has been recently integrated with silicon drift detectors in both a prototype system assembly for the SVT and a silicon drift array for the E896 experiment at the Alternating Gradient Synchrotron at the Brookhaven National Laboratory. We will discuss features of the module's design and fabrication, report the test results, and emphasize its performance both on the bench and under experimental conditions

  4. Structural insight into RNA catalysis revealed by molecular dynamics simulations and QM/MM calculation

    Czech Academy of Sciences Publication Activity Database

    Banáš, P.; Walter, N.G.; Šponer, Jiří; Otyepka, Michal

    2009-01-01

    Roč. 26, č. 6 (2009), s. 816 ISSN 0739-1102. [The 17th Conversation . 16.06.2009-20.06.2009, Albany] Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : QM/MM * RNA Subject RIV: BO - Biophysics

  5. Iron nitride films formed in a r. f. glow discharge

    Energy Technology Data Exchange (ETDEWEB)

    Li, J.L.; O' Keefe, T.J.; James, W.J. (Depts. of Chemistry and Metallurgical Engineering and Graduate Center for Materials Research, Univ. of Missouri-Rolla (United States))

    1992-12-30

    Fe[sub 2]N and Fe[sub 3]N films were deposited on an r.f. glow discharge by introducing Fe(CO)[sub 5] and NH[sub 3] into the reactor. The iron nitride films thus formed exhibited sheet conductivities in the range of 10[sup 2]-10[sup 3] ohm[sup -1] cm[sup -1]. They exhibited microhardness ranging from 578 to 659 kg mm[sup -2] on glass slides. The effects of the deposition temperature and the nature of the substrate material on the structure and composition of the films were investigated. An Fe[sub 4]N layer was formed on iron substrates at 400degC in the plasma nitriding process using NH[sub 3] as the gas source. The Fe[sub 4]N layer exhibited a microhardness of 230 kg mm[sup -2]. The effect of the temperature on the formation of the nitrided layer is discussed. (orig.).

  6. DICOM to print, 35-mm slides, web, and video projector: tutorial using Adobe Photoshop.

    Science.gov (United States)

    Gurney, Jud W

    2002-10-01

    Preparing images for publication has dealt with film and the photographic process. With picture archiving and communications systems, many departments will no longer produce film. This will change how images are produced for publication. DICOM, the file format for radiographic images, has to be converted and then prepared for traditional publication, 35-mm slides, the newest techniques of video projection, and the World Wide Web. Tagged image file format is the common format for traditional print publication, whereas joint photographic expert group is the current file format for the World Wide Web. Each medium has specific requirements that can be met with a common image-editing program such as Adobe Photoshop (Adobe Systems, San Jose, CA). High-resolution images are required for print, a process that requires interpolation. However, the Internet requires images with a small file size for rapid transmission. The resolution of each output differs and the image resolution must be optimized to match the output of the publishing medium.

  7. X-ray analytics for 450-mm wafer; Roentgenanalytik fuer 450-mm-Wafer

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2014-09-15

    The introduction of the 450-mm technology in the wafer fabrication and the further reduction of critical dimensions requires improved X-ray analysis methods. Therefor the PTB has concipated a metrology chamber for the characterization of 450-mm wafers, the crucial element of which is a multi-axis patent-pending manipulator.

  8. SU-F-T-579: Extrapolation Techniques for Small Field Dosimetry Using Gafchromic EBT3 Film

    Energy Technology Data Exchange (ETDEWEB)

    Morales, J [Chris OBrien Lifehouse, Camperdown, NSW (Australia)

    2016-06-15

    Purpose: The purpose of this project is to test an experimental approach using an extrapolation technique for Gafchromic EBT3 film for small field x-ray dosimetry. Methods: Small fields from a Novalis Tx linear accelerator with HD Multileaf Collimators with 6 MV was used. The field sizes ranged from 5 × 5 to 50 × 50 mm2 MLC fields and a range of circular cones of 4 to 30 mm2 diameters. All measurements were performed in water at an SSD of 100 cm and at a depth of 10 cm. The relative output factors (ROFs) were determined from an extrapolation technique developed to eliminate the effects of partial volume averaging in film scan by scanning films with high resolution (1200 DPI). The size of the regions of interest (ROI) was varied to produce a plot of ROFs versus ROI which was then extrapolated to zero ROI to determine the relative output factor. The results were compared with other solid state detectors with proper correction, namely, IBA SFD diode, PTW 60008 and PTW 60012 diode. Results: For the 4 mm cone, the extrapolated ROF had a value of 0.658 ± 0.014 as compared to 0.642 and 0.636 for 0.5 mm and 1 mm2 ROI analysis, respectively. This showed a change in output factor of 2.4% and 3.3% at this comparative ROI sizes. In comparison, the 25 mm cone had a difference in measured output factor of 0.3% and 0.5% between 0.5 and 1.0 mm, respectively compared to zero volume. For the fields defined by MLCs a difference of up to 2% for 5×5 mm2 was observed. Conclusion: A measureable difference can be seen in ROF based on the ROI when radiochromic film is used. Using extrapolation technique from high resolution scanning a good agreement can be achieved.

  9. Growth directions of C8-BTBT thin films during drop-casting

    Science.gov (United States)

    Iizuka, Naoki; Zanka, Tomohiko; Onishi, Yosuke; Fujieda, Ichiro

    2016-02-01

    Because charge transport in a single crystal is anisotropic, control of its orientation is important for enhancing electrical characteristics and reducing variations among devices. For growing an organic thin film, a solution process such as inkjet printing offers advantages in throughput. We have proposed to apply an external temperature gradient during drop-casting and to control the direction of solvent evaporation. In experiment, a temperature gradient was generated in a bare Si substrate by placing it on a Si plate bridging two heat stages. When a solution containing 2,7-dioctyl [1]benzothieno[3,2-b]benzothiophene (C8-BTBT) was dropped on the substrate, evaporation started at the hotter side of the droplet and proceeded toward the colder side. The front line of the liquid was not pinned and the solution extended toward the colder region. As a result, a thin film was formed in a 7mm-long region. The peripheral region of the film was significantly thicker due to the coffee ring effect. The surface of the rest of the film was mostly smooth and terrace structures with 2.6nm steps were observed. The step roughly corresponds to the length of the C8-BTBT molecule. The film thickness varied from 20nm to 50nm over the distance of 3mm. Another film was grown on a glass substrate under a similar condition. Observation of the film with a polarizing microscope revealed that fan-shaped domains were formed in the film and that their optical axes were mostly along the directions of the solvent evaporation.

  10. Discussion of ALTERNATIVE systems for industrial radiography using X-ray films

    International Nuclear Information System (INIS)

    Vaessen B.; Perdieus, P.; Proegler, H.

    1995-01-01

    Industrial radiography using X-ray films is an established method of NDE. In the last few years, ''novel developments'' have been put on the market as ''alternatives'' to conventional radiography, as e.g. fluorescent screen/film systems, cost-saving films, wide-latitude films, and storage phosphor films. AGFA as a market leader in the sector of X-ray films for industrial radiography has been testing these alternatives, taking into account image quality, sensitivity, handling in terms of portability, reliability, and the essential functions for NDE: (1) Detection of X-radiation; (2) conversion to optical image; (3) evaluation and validation; (4) documentation and archivation. The advantages and drawbacks, the information transfer capabilities, and the performance from the applications point of view are discussed primarily for fluorescent screen/film systems and storage phophor systems. (orig./MM) [de

  11. Development of liquid film thickness measurement technique by high-density multipoint electrodes method

    International Nuclear Information System (INIS)

    Arai, Takahiro; Furuya, Masahiro; Kanai, Taizo

    2010-01-01

    High-density multipoint electrode method was developed to measure a liquid film thickness transient on a curved surface. The devised method allows us to measure spatial distribution of liquid film with its conductance between electrodes. The sensor was designed and fabricated as a multilayer print circuit board, where electrode pairs were distributed in reticular pattern with narrow interval. In order to measure a lot of electrode pairs at a high sampling rate, signal-processing method used by the wire mesh sensor measurement system was applied. An electrochemical impedance spectrometry concludes that the sampling rate of 1000 slices/s is feasible without signal distortion by electric double layer. The method was validated with two experimental campaigns: (1) a droplet impingement on a flat film and (2) a jet impingement on a rod-shape sensor surface. In the former experiment, a water droplet having 4 mm in diameter impinged onto the 1 mm thick film layer. A visual observation study with high-speed video camera shows after the liquid impingement, the water layer thinning process was clearly demonstrated with the sensor. For the latter experiment, the flexible circuit board was bended to form a cylindrical shape to measure water film on a simulated fuel rod in bundle geometry. A water jet having 3 mm in diameter impinged onto the rod-shape sensor surface. The process of wetting area enlargement on the rod surface was demonstrated in the same manner that the video-frames showed. (author)

  12. Comparative Study Between Coaptive Film Versus Suture For Wound Closure After Long Bone Fracture Fixation

    Directory of Open Access Journals (Sweden)

    IM Anuar Ramdhan

    2013-03-01

    Full Text Available INTRODUCTION: Coaptive film (i.e., Steri-StripsTM is an adhesive tape used to replace sutures in wound closure. The use of coaptive film for wound closure after long bone fracture fixation has not been well documented in the literature. METHODS: The aim of this prospective, randomized controlled trial comparing coaptive film with sutures for wound closure after long bone fracture fixation was skin closure time, incidence of wound complications and scar width at 12 week follow-up. Forty-five patients underwent femur fracture fixation (22 patients’ wound closed with sutures, 23 with coaptive film. RESULTS: The mean time for skin closure using coaptive film was 171.13 seconds compared to 437.27 seconds using suture. The mean wound lengths in the coaptive film group and suture group were 187.65 mm and 196.73 mm, respectively. One patient in each group had wound complications. CONCLUSION: Coaptive film is a time-saving procedure for skin closure following long bone fracture fixation. There is no difference in the incidence of wound complications and scar width between these two methods of skin closure.

  13. Droplet deposition measurement with high-speed camera and novel high-speed liquid film sensor with high spatial resolution

    International Nuclear Information System (INIS)

    Damsohn, M.; Prasser, H.-M.

    2011-01-01

    Highlights: → Development of a sensor for time- and space-resolved droplet deposition in annular flow. → Experimental measurement of droplet deposition in horizontal annular flow to compare readings of the sensor with images of a high-speed camera when droplets are depositing unto the liquid film. → Self-adaptive signal filter based on autoregression to separate droplet impacts in the sensor signal from waves of liquid films. - Abstract: A sensor based on the electrical conductance method is presented for the measurement of dynamic liquid films in two-phase flow. The so called liquid film sensor consists of a matrix with 64 x 16 measuring points, a spatial resolution of 3.12 mm and a time resolution of 10 kHz. Experiments in a horizontal co-current air-water film flow were conducted to test the capability of the sensor to detect droplet deposition from the gas core onto the liquid film. The experimental setup is equipped with the liquid film sensor and a high speed camera (HSC) recording the droplet deposition with a sampling rate of 10 kHz simultaneously. In some experiments the recognition of droplet deposition on the sensor is enhanced by marking the droplets with higher electrical conductivity. The comparison between the HSC and the sensor shows, that the sensor captures the droplet deposition above a certain droplet diameter. The impacts of droplet deposition can be filtered from the wavy structures respectively conductivity changes of the liquid film using a filter algorithm based on autoregression. The results will be used to locally measure droplet deposition e.g. in the proximity of spacers in a subchannel geometry.

  14. Transjugular Intrahepatic Portosystemic Shunts in Patients with Cirrhosis with Refractory Ascites: Comparison of Clinical Outcomes by Using 8- and 10-mm PTFE-covered Stents.

    Science.gov (United States)

    Miraglia, Roberto; Maruzzelli, Luigi; Tuzzolino, Fabio; Petridis, Ioannis; D'Amico, Mario; Luca, Angelo

    2017-07-01

    Purpose To compare the efficacy and complications of transjugular intrahepatic portosystemic shunt (TIPS) creation performed by using a 10-mm or an 8-mm-diameter polytetrafluoroethylene (PTFE)-covered stent in a consecutive series of patients with cirrhosis with refractory ascites (RA). Materials and Methods The institutional review board approved this retrospective study and informed consent was waived. One hundred seventy-one patients with RA (mean age, 58.7 years ± 10.3; 95% confidence interval [CI]: 57.2 years, 60.3 years) had undergone TIPS placement by using 10-mm (60 patients) or 8-mm (111 patients) covered stent between January 2004 and December 2012. Median follow-up time was 16.8 months (range, 3.4-84.8 months). Hemodynamic changes, incidence of hepatic encephalopathy, and long-term (>3 months) need for paracentesis after TIPS placement were evaluated and calculated by using the Kaplan-Meier method and were compared by using the log-rank test. Results Pre-TIPS demographics and clinical characteristics of the two groups were comparable. The portosystemic gradient before TIPS was 17.0 mm Hg ± 4.2 (95% CI: 15.9 mm Hg, 18.1 mm Hg) in the 10-mm group versus 16.1 mm Hg ± 3.7 (95% CI: 15.4 mm Hg, 16.8 mm Hg) in the 8-mm group (P = .164). After TIPS, the portosystemic gradient was 6.5 mm Hg ± 3.4 (95% CI: 5.7 mm Hg, 7.4 mm Hg) in the 10-mm group versus 7.5 mm Hg ± 2.6 (95% CI: 6.9 mm Hg, 7.9 mm Hg) in the 8-mm group (P = .039). The long-term need for paracentesis was greater in the 8-mm group (64 of 111 patients [58%] vs 18 of 60 patients [31%], P = .003). Overall, hepatic encephalopathy was similar in both groups (45 of 111 patients [41%] vs 26 of 60 patients [44%], P = .728). Conclusion A10-mm PTFE-covered stent leads to better control of RA secondary to portal hypertension in patients with cirrhosis, compared with an 8-mm stent, without increasing the incidence of hepatic encephalopathy. © RSNA, 2017.

  15. Stability of tetraphenyl butadiene thin films in liquid xenon

    International Nuclear Information System (INIS)

    Sanguino, P.; Balau, F.; Botelho do Rego, A.M.; Pereira, A.; Chepel, V.

    2016-01-01

    Tetraphenyl butadiene (TPB) is widely used in particle detectors as a wavelength shifter. In this work we studied the stability of TPB thin films when immersed in liquid xenon (LXe). The thin films were deposited on glass and quartz substrates by thermal evaporation. Morphological and chemical surface properties were monitored before and after immersion into LXe by scanning electron microscopy and X-ray photoelectron spectroscopy. No appreciable changes have been detected with these two methods. Grain size and surface chemical composition were found to be identical before and after submersion into LXe. However, the film thickness, measured via optical transmission in the ultraviolet–visible wavelength regions, decreased by 1.6 μg/cm 2 (24%) after immersion in LXe during 20 h. These results suggest the necessity of using a protective thin film over the Tetraphenyl butadiene when used as a wavelength shifter in LXe particle detectors. - Highlights: • Stability of tetraphenyl butadiene (TPB) thin films immersed in liquid xenon (LXe). • Thermally evaporated TPB thin films were immersed in LXe for 20 h. • Film morphology and chemical surface properties remained unchanged. • Surface density of the films decreased by 1.6 μg/cm 2 (24%) after immersion in LXe. • For using in LXe particle detectors, TPB films should be protected with a coating.

  16. Thickness determination of large-area films of yttria-stabilized zirconia produced by pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Pryds, N. [Materials Research Department, Riso National Laboratory, DK-4000 Roskilde (Denmark)]. E-mail: nini.pryds@risoe.dk; Toftmann, B. [Department of Optics and Plasma Research, Riso National Laboratory, DK-4000 Roskilde (Denmark); Bilde-Sorensen, J.B. [Materials Research Department, Riso National Laboratory, DK-4000 Roskilde (Denmark); Schou, J. [Department of Optics and Plasma Research, Riso National Laboratory, DK-4000 Roskilde (Denmark); Linderoth, S. [Materials Research Department, Riso National Laboratory, DK-4000 Roskilde (Denmark)

    2006-04-30

    Films of yttria-stabilized zirconia (YSZ) on a polished silicon substrate of diameter up to 125 mm have been produced in a large-area pulsed laser deposition (PLD) setup under typical PLD conditions. The film thickness over the full film area has been determined by energy-dispersive X-ray spectrometry in a scanning electron microscope (SEM) with use of a method similar to one described by Bishop and Poole. The attenuation of the electron-induced X-rays from the Si wafer by the film was monitored at a number of points along a diameter and the thickness was determined by Monte Carlo simulations of the attenuation for various values of film thickness with the program CASINO. These results have been compared with direct measurements in the SEM of the film thickness on a cross-section on one of the wafers. The results of these measurements demonstrate the ability of this technique to accurately determine the thickness of a large film, i.e. up to diameters of 125 mm, in a relatively short time, without destroying the substrate, without the need of a standard sample and without the need of a flat substrate. We have also demonstrated that by controlling the deposition parameters large-area YSZ films with uniform thickness can be produced.

  17. Thickness determination of large-area films of yttria-stabilized zirconia produced by pulsed laser deposition

    International Nuclear Information System (INIS)

    Pryds, N.; Toftmann, B.; Bilde-Sorensen, J.B.; Schou, J.; Linderoth, S.

    2006-01-01

    Films of yttria-stabilized zirconia (YSZ) on a polished silicon substrate of diameter up to 125 mm have been produced in a large-area pulsed laser deposition (PLD) setup under typical PLD conditions. The film thickness over the full film area has been determined by energy-dispersive X-ray spectrometry in a scanning electron microscope (SEM) with use of a method similar to one described by Bishop and Poole. The attenuation of the electron-induced X-rays from the Si wafer by the film was monitored at a number of points along a diameter and the thickness was determined by Monte Carlo simulations of the attenuation for various values of film thickness with the program CASINO. These results have been compared with direct measurements in the SEM of the film thickness on a cross-section on one of the wafers. The results of these measurements demonstrate the ability of this technique to accurately determine the thickness of a large film, i.e. up to diameters of 125 mm, in a relatively short time, without destroying the substrate, without the need of a standard sample and without the need of a flat substrate. We have also demonstrated that by controlling the deposition parameters large-area YSZ films with uniform thickness can be produced

  18. Structural study of Ge/GaAs thin films

    International Nuclear Information System (INIS)

    Lazarov, V K; Lari, L; Lytvyn, P M; Kholevchuk, V V; Mitin, V F

    2012-01-01

    Ge/GaAs heterostructure research is largely motivated by the application of this material in solar cells, metal-oxide-semiconductor field-effect transistors, mm-wave mixer diodes, temperature sensors and photodetectors. Therefore, understanding of how the properties of Ge/GaAs heterostructure depend on its preparation (growth) is of importance for various high-efficiency devices. In this work, by using thermal Ge evaporation on GaAs(100), we studied structural properties of these films as a function of the deposition rate. Film grains size and morphology show strong dependence of the deposition rate. Low deposition rates results in films with large crystal grains and rough surface. At high deposition rates films become flatter and their crystal grains size decreases, while at very high deposition rates films become amorphous. Cross-sectional TEM of the films show that the Ge films are granular single crystal epitaxially grown on GaAs. The Ge/GaAs interface is atomically abrupt and free from misfit dislocations. Stacking faults along the [111] directions that originate at the interface were also observed. Finally by using the Kelvin probe microscopy we show that work function changes are related to the grain structure of the film.

  19. THE RADIO-2 mm SPECTRAL INDEX OF THE CRAB NEBULA MEASURED WITH GISMO

    International Nuclear Information System (INIS)

    Arendt, R. G.; George, J. V.; Staguhn, J. G.; Benford, D. J.; Fixsen, D. J.; Maher, S. F.; Moseley, S. H.; Sharp, E.; Wollack, E. J.; Devlin, M. J.; Dicker, S. R.; Korngut, P. M.; Irwin, K. D.; Jhabvala, C. A.; Miller, T. M.; Kovacs, A.; Mason, B. S.; Navarro, S.; Sievers, A.; Sievers, J. L.

    2011-01-01

    We present results of 2 mm observations of the Crab Nebula, obtained using the Goddard-IRAM Superconducting 2 Millimeter Observer (GISMO) bolometer camera on the IRAM 30 m telescope. Additional 3.3 mm observations with the MUSTANG bolometer array on the Green Bank Telescope are also presented. The integrated 2 mm flux density of the Crab Nebula provides no evidence for the emergence of a second synchrotron component that has been proposed. It is consistent with the radio power-law spectrum, extrapolated up to a break frequency of log (ν b [GHz]) = 2.84 ± 0.29 or ν b = 695 +651 -336 GHz. The Crab Nebula is well resolved by the ∼16.''7 beam (FWHM) of GISMO. Comparison to radio data at comparable spatial resolution enables us to confirm significant spatial variation of the spectral index between 21 cm and 2 mm. The main effect is a spectral flattening in the inner region of the Crab Nebula, correlated with the toroidal structure at the center of the nebula that is prominent in the near-IR through X-ray regime.

  20. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  1. Flexibility of the Indium Tin Oxide Transparent Conductive Film Deposited Onto the Plastic Substrate

    Directory of Open Access Journals (Sweden)

    Shao-Kai Lu

    2014-03-01

    Full Text Available In this study, we utilize the RF magnetron sputtering system to deposit the indium tin oxide (ITO conductive transparent film with low resistivity and high light transmittance to the polyethylene tetephthalate (PET plastic substrate and measure the film’s bending property and reliability at different tensile/compressive strain bending curvatures as well as the flexibility after cycling bending. The results show that the critical curvatures corresponded to the significant increase in the resistance of the 150 nm-thick ITO film deposited onto the PET substrate under tensile and compressive stress areO 14.1 mm and 5.4 mm, respectively. By observing the film’s surface crack and morphology, we can further discover that the critical curvature of the crack generated when the film is bent is quite consistent with the critical curvature at which the conductivity property degrades, and the film can withstand a higher compressive strain bending. In addition, the resistance and adhesion behavior of the film almost is unchanged after cycling bent for 1000 times with the curvature below the critical curvature.

  2. Fracture toughness improvements of dental ceramic through use of yttria-stabilized zirconia (YSZ) thin-film coatings.

    Science.gov (United States)

    Chan, Ryan N; Stoner, Brian R; Thompson, Jeffrey Y; Scattergood, Ronald O; Piascik, Jeffrey R

    2013-08-01

    The aim of this study was to evaluate strengthening mechanisms of yttria-stabilized zirconia (YSZ) thin film coatings as a viable method for improving fracture toughness of all-ceramic dental restorations. Bars (2mm×2mm×15mm, n=12) were cut from porcelain (ProCAD, Ivoclar-Vivadent) blocks and wet-polished through 1200-grit using SiC abrasive. A Vickers indenter was used to induce flaws with controlled size and geometry. Depositions were performed via radio frequency magnetron sputtering (5mT, 25°C, 30:1 Ar/O2 gas ratio) with varying powers of substrate bias. Film and flaw properties were characterized by optical microscopy, scanning electron microscopy (SEM), and X-ray diffraction (XRD). Flexural strength was determined by three-point bending. Fracture toughness values were calculated from flaw size and fracture strength. Data show improvements in fracture strength of up to 57% over unmodified specimens. XRD analysis shows that films deposited with higher substrate bias displayed a high %monoclinic volume fraction (19%) compared to non-biased deposited films (87%), and resulted in increased film stresses and modified YSZ microstructures. SEM analysis shows critical flaw sizes of 67±1μm leading to fracture toughness improvements of 55% over unmodified specimens. Data support surface modification of dental ceramics with YSZ thin film coatings to improve fracture toughness. Increase in construct strength was attributed to increase in compressive film stresses and modified YSZ thin film microstructures. It is believed that this surface modification may lead to significant improvements and overall reliability of all-ceramic dental restorations. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. File list: His.PSC.50.H4K16ac.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.PSC.50.H4K16ac.AllCell mm9 Histone H4K16ac Pluripotent stem cell SRX212325,SRX2...98193,SRX212326,SRX298194 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.PSC.50.H4K16ac.AllCell.bed ...

  4. File list: His.PSC.20.H4K16ac.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.PSC.20.H4K16ac.AllCell mm9 Histone H4K16ac Pluripotent stem cell SRX298193,SRX2...12325,SRX212326,SRX298194 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.PSC.20.H4K16ac.AllCell.bed ...

  5. Horizontally-connected ZnO-graphene hybrid films for multifunctional devices

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Yi Rang [Thin Film Materials Research Center, Korea Research Institute of Chemical Technology, Yuseong Post Office Box 107, Daejeon 305-600 (Korea, Republic of); School of Semiconductor and Chemical Engineering, Semiconductor Physics Research Center (SPRC), Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Song, Wooseok; Lee, Young Bum; Kim, Seong Ku; Han, Jin Kyu; Myung, Sung; Lee, Sun Sook; An, Ki-Seok [Thin Film Materials Research Center, Korea Research Institute of Chemical Technology, Yuseong Post Office Box 107, Daejeon 305-600 (Korea, Republic of); Choi, Chel-Jong [School of Semiconductor and Chemical Engineering, Semiconductor Physics Research Center (SPRC), Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Lim, Jongsun, E-mail: jslim@krict.re.kr [Thin Film Materials Research Center, Korea Research Institute of Chemical Technology, Yuseong Post Office Box 107, Daejeon 305-600 (Korea, Republic of)

    2016-08-30

    Highlights: • We designed horizontally-connected ZnO and graphene hybrid nanofilms with improved flexibility for multifunctional nanodevices including high performance TFTs. • The photocurrent on-off ratio, response time, and recovery time of the hybrid photodetectors were estimated to be 10{sup 2}, 34 s, and 27 s, respectively. The photocurrent from the hybrid photodetector decreased only by two-fold, whereas a significant decrease in photocurrent by two orders of magnitude was observed from the ZnO thin film based photodetectors after 10{sup 5} cycles of 5-mm radius bending. • The hybrid thin film transistors exhibited unipolar n-channel transistor behavior with electron mobility of 68.7 cm{sup 2}/V s and on-off ratio of 10{sup 7}. - Abstract: Here we designed horizontally-connected ZnO thin films and graphene in order to combine advantages of ZnO thin films, which are high on/off ratio and photo responsivity, and the superior mobility and sensitivity of graphene for applications in thin film transistors (TFTs) and flexible photodetectors. To synthesize the ZnO/graphene hybrid films, a 70-nm-thick ZnO thin film with a uniformly flat surface deposited by the atomic layer deposition process was horizontally connected with highly crystalline monolayer graphene grown by thermal chemical vapor deposition. The photocurrent on-off ratio, response time, and recovery time of the hybrid photodetectors were estimated to be 10{sup 2}, 34 s, and 27 s, respectively. The photocurrent from the hybrid photodetector decreased only by two-fold, whereas a significant decrease in photocurrent by two orders of magnitude was observed from the ZnO thin film based photodetectors after 10{sup 5} cycles of 5-mm radius bending. The hybrid TFT exhibited unipolar n-channel transistor behavior with electron mobility of 68.7 cm{sup 2}/V s and on-off ratio of 10{sup 7}.

  6. Development of liquid-lithium film jet-flow for the target of (7)Li(p,n)(7)Be reactions for BNCT.

    Science.gov (United States)

    Kobayashi, Tooru; Miura, Kuniaki; Hayashizaki, Noriyosu; Aritomi, Masanori

    2014-06-01

    A feasibility study on liquid lithium target in the form of a flowing film was performed to evaluate its potential use as a neutron generation target of (7)Li(p,n)(7)Be reaction in BNCT. The target is a windowless-type flowing film on a concave wall. Its configuration was adapted for a proton beam which is 30mm in diameter and with energy and current of up to 3MeV and 20mA, respectively. The flowing film of liquid lithium was 0.6mm in thickness, 50mm in width and 50mm in length. The shapes of the nozzle and concave back wall, which create a stable flowing film jet, were decided based on water experiments. A lithium hydrodynamic experiment was performed to observe the stability of liquid lithium flow behavior. The flowing film of liquid lithium was found to be feasible at temperatures below the liquid lithium boiling saturation of 342°C at the surface pressure of 1×10(-3)Pa. Using a proto-type liquid lithium-circulating loop for BNCT, the stability of the film flow was confirmed for velocities up to 30m/s at 220°C and 250°C in vacuum at a pressure lower than 10(-3) Pa. It is expected that for practical use, a flowing liquid lithium target of a windowless type can solve the problem of radiation damage and target cooling. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Fabrication and application of flexible graphene silk composite film electrodes decorated with spiky Pt nanospheres

    Science.gov (United States)

    Liang, Bo; Fang, Lu; Hu, Yichuan; Yang, Guang; Zhu, Qin; Ye, Xuesong

    2014-03-01

    A free-standing graphene silk composite (G/S) film was fabricated via vacuum filtration of a mixed suspension of graphene oxide and silk fibres, followed by chemical reduction. Spiky structured Pt nanospheres were grown on the film substrate by cyclic voltammetry electrodeposition. The electrical and mechanical performance of a single graphene coated silk fibre was investigated. The conductivity of a single graphene coated silk fibre is 57.9 S m-1. During 1000 bending measurements, the conductivity was stable and showed negligible variation. The G/S film has a sheet resistivity of 90 Ω □-1 with a porous and hierarchical structure. The spiky Pt nanosphere decorated G/S film was directly used as a H2O2 electrode with a sensitivity of 0.56 mA mM-1 cm-2, a linear range of 0-2.5 mM and an ultralow detection limit of 0.2 μM (S/N = 3). A glucose biosensor electrode was further fabricated by enzyme immobilization. The results show a sensitivity of 150.8 μA mM-1 cm-2 and a low detection limit of 1 μM (S/N = 3) for glucose detection. The strategy of coating graphene sheets on a silk fibre surface provides a new approach for developing electrically conductive biomaterials, tissue engineering scaffolds, bendable electrodes, and wearable biomedical devices.A free-standing graphene silk composite (G/S) film was fabricated via vacuum filtration of a mixed suspension of graphene oxide and silk fibres, followed by chemical reduction. Spiky structured Pt nanospheres were grown on the film substrate by cyclic voltammetry electrodeposition. The electrical and mechanical performance of a single graphene coated silk fibre was investigated. The conductivity of a single graphene coated silk fibre is 57.9 S m-1. During 1000 bending measurements, the conductivity was stable and showed negligible variation. The G/S film has a sheet resistivity of 90 Ω □-1 with a porous and hierarchical structure. The spiky Pt nanosphere decorated G/S film was directly used as a H2O2 electrode with a

  8. Technical Note: Initial characterization of the new EBT-XD Gafchromic film.

    Science.gov (United States)

    Grams, Michael P; Gustafson, Jon M; Long, Kenneth M; de los Santos, Luis E Fong

    2015-10-01

    To assess the dosimetric accuracy and energy dependence of the new EBT-eXtended Dose (XD) Gafchromic film and to compare the lateral response artifact (LRA) between EBT-XD and EBT3 film. EBT3 and EBT-XD calibration curves were created by exposing films to known doses from 0 to 3000 cGy using a 6 MV beam. To assess the accuracy and dynamic range of EBT-XD, a 60° enhanced dynamic wedge (EDW) was used to deliver a dose range of approximately 200-2900 cGy. Comparison to treatment planning system (TPS) calculation was made using a gamma analysis with 2%/2 mm passing criteria. To assess and compare the LRA between EBT3 and EBT-XD, 21 × 21 cm(2) open fields delivered doses of 1000, 2000, and 3000 cGy to both types of film. Films were placed at the center of the scanner, and ratios of measured to TPS predicted doses were calculated at 50 and 80 mm lateral from the scanner center in order to quantitatively assess the LRA. To evaluate the energy dependence of EBT-XD film, seven known doses ranging from 400 to 3000 cGy were delivered using both 6 and 18 MV beams and the resulting optical densities (ODs) compared. The gamma passing rate was 99.1% for the 6 MV EDW delivery. EBT-XD film exhibited minimal LRA (XD films exposed to known doses from 6 to 18 MV beams were XD is greatly reduced when compared to EBT3. This in combination with its accuracy from 0 to 3000 cGy and minimal energy dependence from 6 to 18 MV makes EBT-XD film well suited for dosimetric measurements in high dose SRS/SBRT applications.

  9. Synthesis of thick diamond films by direct current hot-cathode plasma chemical vapour deposition

    CERN Document Server

    Jin Zeng Sun; Bai Yi Zhen; Lu Xian Yi

    2002-01-01

    The method of direct current hot-cathode plasma chemical vapour deposition has been established. A long-time stable glow discharge at large discharge current and high gas pressure has been achieved by using a hot cathode in the temperature range from 1100 degree C to 1500 degree C and non-symmetrical configuration of the poles, in which the diameter of the cathode is larger than that of anode. High-quality thick diamond films, with a diameter of 40-50 mm and thickness of 0.5-4.2 mm, have been synthesized by this method. Transparent thick diamond films were grown over a range of growth rates between 5-10 mu m/h. Most of the thick diamond films have thermal conductivities of 10-12 W/K centre dot cm. The thick diamond films with high thermal conductivity can be used as a heat sink of semiconducting laser diode array and as a heat spreading and isolation substrate of multichip modules. The performance can be obviously improved

  10. NdFeB thick films prepared by tape casting

    International Nuclear Information System (INIS)

    Pawlowski, B.; Schwarzer, S.; Rahmig, A.; Toepfer, J.

    2003-01-01

    NdFeB films of thickness between 100 and 800 μm were prepared by tape casting of a slurry containing 84-95 wt% of commercial NdFeB powder (MQP-B, -Q and -S). After curing the flexible green tapes at 120 deg. C non-porous magnetic films are obtained. The remanence of the films is in the range of 350-450 mT and the coercivity is between 300 and 800 kA/m depending on the type of MQP powder used. The magnetic properties of the films are discussed in relation to film composition and type of magnetic material. For MEMS applications the thick films are magnetized with a multi-pole stripe pattern with 1 mm pole pitch. The induction at the surface of the films was measured with a Hall probe and compared to theoretical calculations. The results indicate that the films are completely magnetized regardless of the film thickness. Tape-casted NdFeB thick films are promising candidates for applications in micro-systems or actuators. Miniaturization of the magnet components is one of the key issues in the development of electromagnetic micro-systems, thus creating a need for replacement of small sintered magnets by magnetic thick film components. Other applications include encoders

  11. Composite outcomes in 2.25-mm drug eluting stents: a systematic review

    International Nuclear Information System (INIS)

    Lee, Justin Z.; Singh, Nirmal; Ortega, Gilbert; Low, See Wei; Kanakadandi, Uday; Fortuin, F. David; Lassar, Tom; Lee, Kwan S.

    2015-01-01

    Background: Coronary atherosclerosis often involves small-caliber coronaries, yet the safety and efficacy of 2.25-mm DES have been poorly defined, with a general lack of separation of 2.25 with 2.5-mm performance. No randomized head-to-head 2.25 mm DES studies have been reported. There are several single-arm prospective studies, and we aim to systematically review all published specific 2.25-mm data to estimate composite DES-specific performance and highlight current knowledge gaps. Methods: We performed a systematic literature search of PubMed, EMBASE, Web of Science and Cochrane database for clinical trials of 2.25-mm DES. Angiographic and composite clinical outcomes were compared with descriptive statistics. Results: 2.25 mm-Paclitaxel (PES), sirolimus (SES), everolimus (EES) and platinum chromium EES DES-specific outcomes have been reported. Death at 12 months for SES, PES, EES and platinum chromium EES was 1.3%, 3.0%, 1.5%, and 4.4%. Rates of target vessel revascularization at 12 months for SES, PES, EES and platinum chromium EES were 5.7%, 13.3%, 8.8%, and 3.3%. Angiographic outcomes at 9 months to one year were as follows: mean late lumen loss (LLL) for SES, PES, and EES was 0.15 ± 0.11-mm, 0.28 ± 0.11-mm, and 0.16 ± 0.41-mm and mean diameter restenosis for SES, PES, and EES were 29.5 ± 6.2%, 34.7 ± 4.2%, and 20.9 ± 22.5%. Reported stent thrombosis rates for 2.25-mm DES were low ranging from 0% to 2.2% in up to 24-months of follow-up. Conclusions: This systematic review summarizes and tabulates all available specific data on 2.25-mm DES. Based on our descriptive analysis, 2.25-mm DESs have a favorable safety and efficacy profile for the treatment of very small coronary lesions. - Highlights: • Safety and efficacy of 2.25-mm DES have been poorly defined. • We performed a systematic review on all published 2.25 mm data to estimate composite DES-specific performance and highlight current knowledge gaps. • We pooled data from 9 clinical studies and 1

  12. Composite outcomes in 2.25-mm drug eluting stents: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Justin Z. [Department of Medicine, University of Arizona, 1501 N Campbell Avenue, Tucson, AZ, 85724 (United States); Singh, Nirmal [Department of Cardiovascular Diseases, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States); Ortega, Gilbert [College of Medicine, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States); Low, See Wei; Kanakadandi, Uday [Department of Cardiovascular Diseases, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States); Fortuin, F. David [Department of Cardiovascular Diseases, Mayo Clinic Arizona, 5777 East Mayo Boulevard, Phoenix, AZ, 85054 (United States); Lassar, Tom [Department of Cardiovascular Diseases, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States); Lee, Kwan S., E-mail: klee@shc.arizona.edu [Department of Cardiovascular Diseases, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States)

    2015-06-15

    Background: Coronary atherosclerosis often involves small-caliber coronaries, yet the safety and efficacy of 2.25-mm DES have been poorly defined, with a general lack of separation of 2.25 with 2.5-mm performance. No randomized head-to-head 2.25 mm DES studies have been reported. There are several single-arm prospective studies, and we aim to systematically review all published specific 2.25-mm data to estimate composite DES-specific performance and highlight current knowledge gaps. Methods: We performed a systematic literature search of PubMed, EMBASE, Web of Science and Cochrane database for clinical trials of 2.25-mm DES. Angiographic and composite clinical outcomes were compared with descriptive statistics. Results: 2.25 mm-Paclitaxel (PES), sirolimus (SES), everolimus (EES) and platinum chromium EES DES-specific outcomes have been reported. Death at 12 months for SES, PES, EES and platinum chromium EES was 1.3%, 3.0%, 1.5%, and 4.4%. Rates of target vessel revascularization at 12 months for SES, PES, EES and platinum chromium EES were 5.7%, 13.3%, 8.8%, and 3.3%. Angiographic outcomes at 9 months to one year were as follows: mean late lumen loss (LLL) for SES, PES, and EES was 0.15 ± 0.11-mm, 0.28 ± 0.11-mm, and 0.16 ± 0.41-mm and mean diameter restenosis for SES, PES, and EES were 29.5 ± 6.2%, 34.7 ± 4.2%, and 20.9 ± 22.5%. Reported stent thrombosis rates for 2.25-mm DES were low ranging from 0% to 2.2% in up to 24-months of follow-up. Conclusions: This systematic review summarizes and tabulates all available specific data on 2.25-mm DES. Based on our descriptive analysis, 2.25-mm DESs have a favorable safety and efficacy profile for the treatment of very small coronary lesions. - Highlights: • Safety and efficacy of 2.25-mm DES have been poorly defined. • We performed a systematic review on all published 2.25 mm data to estimate composite DES-specific performance and highlight current knowledge gaps. • We pooled data from 9 clinical studies and 1

  13. Metal-chelating active packaging film enhances lysozyme inhibition of Listeria monocytogenes.

    Science.gov (United States)

    Roman, Maxine J; Decker, Eric A; Goddard, Julie M

    2014-07-01

    Several studies have demonstrated that metal chelators enhance the antimicrobial activity of lysozyme. This study examined the effect of metal-chelating active packaging film on the antimicrobial activity of lysozyme against Listeria monocytogenes. Polypropylene films were surface modified by photoinitiated graft polymerization of acrylic acid (PP-g-PAA) from the food contact surface of the films to impart chelating activity based on electrostatic interactions. PP-g-PAA exhibited a carboxylic acid density of 113 ± 5.4 nmol cm(-2) and an iron chelating activity of 53.7 ± 9.8 nmol cm(-2). The antimicrobial interaction of lysozyme and PP-g-PAA depended on growth media composition. PP-g-PAA hindered lysozyme activity at low ionic strength (2.48-log increase at 64.4 mM total ionic strength) and enhanced lysozyme activity at moderate ionic strength (5.22-log reduction at 120 mM total ionic strength). These data support the hypothesis that at neutral pH, synergy between carboxylate metal-chelating films (pKa(bulk) 6.45) and lysozyme (pI 11.35) is optimal in solutions of moderate to high ionic strength to minimize undesirable charge interactions, such as lysozyme absorption onto film. These findings suggest that active packaging, which chelates metal ions based on ligand-specific interactions, in contrast to electrostatic interactions, may improve antimicrobial synergy. This work demonstrates the potential application of metal-chelating active packaging films to enhance the antimicrobial activity of membrane-disrupting antimicrobials, such as lysozyme.

  14. On the use of Gafchromic EBT3 films for validating a commercial electron Monte Carlo dose calculation algorithm.

    Science.gov (United States)

    Chan, EuJin; Lydon, Jenny; Kron, Tomas

    2015-03-07

    This study aims to investigate the effects of oblique incidence, small field size and inhomogeneous media on the electron dose distribution, and to compare calculated (Elekta/CMS XiO) and measured results. All comparisons were done in terms of absolute dose. A new measuring method was developed for high resolution, absolute dose measurement of non-standard beams using Gafchromic® EBT3 film. A portable U-shaped holder was designed and constructed to hold EBT3 films vertically in a reproducible setup submerged in a water phantom. The experimental film method was verified with ionisation chamber measurements and agreed to within 2% or 1 mm. Agreement between XiO electron Monte Carlo (eMC) and EBT3 was within 2% or 2 mm for most standard fields and 3% or 3 mm for the non-standard fields. Larger differences were seen in the build-up region where XiO eMC overestimates dose by up to 10% for obliquely incident fields and underestimates the dose for small circular fields by up to 5% when compared to measurement. Calculations with inhomogeneous media mimicking ribs, lung and skull tissue placed at the side of the film in water agreed with measurement to within 3% or 3 mm. Gafchromic film in water proved to be a convenient high spatial resolution method to verify dose distributions from electrons in non-standard conditions including irradiation in inhomogeneous media.

  15. Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.

    Science.gov (United States)

    Childress, Nathan L; Salehpour, Mohammad; Dong, Lei; Bloch, Charles; White, R Allen; Rosen, Isaac I

    2005-02-01

    difference and 2 mm criteria to ion chamber measurements for both sliding window and step-and-shoot fluence map verifications. Calibrated film results agreed with ion chamber measurements to within 5 % /2 mm criteria for transverse-plane full-plan verifications, but were consistently low. When properly calibrated, EDR2 film can be an adequate two-dimensional dosimeter for IMRT verifications, although it may underestimate doses in regions with long exposure times.

  16. Dye film dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Humphreys, J.C.; McLaughlin, W.L.

    1981-01-01

    Commercially available plastic films containing dyes or dye precursors are convenient dosimeters and imaging media for electron beams or photons used for industrial radiation processing. As ''grainless'' imaging systems having thicknesses down to a few micrometers, they provide high spatial resolution for determining detailed absorbed dose distributions through microdensitometric analysis. The radiation absorption properties of these systems are adjusted by changing film composition so that the dosimeter materials can be made to simulate the material of interest undergoing irradiation. Other advantages include long-term stability, dose-rate independence, and ease of use and calibration. Radiochromic dye films with thicknesses varying from 0.005 to 1 mm are presently used to monitor electron-beam or gamma-ray doses from 10 to 10 5 Gy (10 3 to 10 7 rad), typical of those encountered in medical applications, radiation curing of polymeric composites, wire and cable insulation, shrinkable plastic tubing and film, as well as sterilization of medical supplies and treatment of municipal and industrial wastes. An NBS calibration service to industry involves the traceability of standard 60 Co gamma ray absorbed dose measurements by means of these films employed as transfer standards

  17. Fabricação de filmes bionanocompósitos à base de pectina e polpa de cacau com potencial uso como embalagem para alimentos

    Directory of Open Access Journals (Sweden)

    Pamela Thais S. Melo

    Full Text Available The aim of this work was to produce biodegradable films based on the pectin and cocoa puree reinforced with chitosan nanoparticles. Nanoparticles were obtained by the ionotropic gelation. Films were produced according to the "casting" method, through a colloidal solution composed of water, cocoa puree, chitosan nanoparticles solution and different concentrations of pectin (2% and 3% w/w. Films were analyzed by thickness measurements, water vapor permeability, mechanical properties and scanning electron microscopy. Nanoparticles were characterized by zeta potential and showed spherical shape with a diameter of about 110 nm and zeta potential value of approximately +30 mV. Pectin 2% and 3% cocoa films exhibited tensile strength (mPa of 15.1 ± 0.7 and 22.9 ± 1.6, respectively. After nanostructures addition, values increased to 25.2 ± 0.7 and 29.8 ± 1.3. Increasing concentration polymer and chitosan nanoparticles to improve tensile strength values. Films contained 3% of pectin exhibited more significant decrease in water vapor permeability values when chitosan nanoparticles were added, from 2.470 ± 0.101 to 1.904 ± 0.125 g mm / kPa h m2. Results of the analyzes demonstrated that nanocomposites produced with pectin of different concentration showed satisfactory properties for application as packaging for food.

  18. Composition and performance of thin film CdSe electrodeposited from selenosulfite solution

    International Nuclear Information System (INIS)

    Szabo, J.P.; Simms, D.; Cocivera, M.

    1985-01-01

    Cathodic electrodeposition of thin film CdSe from aqueous selenosulfite solution has been studied as function of solution composition and electrode potential. The Cd/Se ratio has been analyzed using polarography and Rutherford backscattering spectroscopy. Polarography gives a compostion averaged over the whole film (2cm 2 ) while RBS gives local surface composition (1 mm 2 ). The average Cd/Se ratio is 1.1, but some variation was found to occur across the surface of film (0.82 to 1.2)

  19. Measuring a film flowing down a tube inner wall using a laser focus displacement meter and an image-processing method

    International Nuclear Information System (INIS)

    Takamasa, Tomoji; Kobayashi, Kenji

    1999-01-01

    To elucidate details of the fascinating nonlinear phenomena of waves on a film, spatial temporal knowledge of the interfacial waves is essential. This paper presents an experimental study on waves on a film flowing down a vertical tube inner wall measured with a laser focus displacement meter (LFD) and an image-processing method. As a result, the film thickness was measured within a 1% margin of error by LFD, and the wave velocity was measured within a 10% margin of error by the image-processing. The experimental results are summarized as follows: At entry length L = 900 mm, the wave becomes a two-wave system. In the entry region, L = 216 mm, and 400 mm, the wave amplitude decreases as the flow rate increases, in the same manner as that in a film flowing down a plate wall. The velocity measured by the image processing agreed well with that calculated using Nusselt's theoretical equation and the Ito-Sasaki empirical equation for Reynolds numbers < 250. (author)

  20. Edible Film from the Pectin of Papaya Skin (The Study of Cassava Starch and Glycerol Addition)

    Science.gov (United States)

    Rosida; Sudaryati; Yahya, A. M.

    2018-01-01

    The production of edible cooking made from the pectin of papaya skin with cassava starch and glycerol adition had been studied. The usage of pectin of papaya skin was one way to use papaya skin waste in order to raise its economic value. The aim of this study was to study the effect of cassava starch and glycerol concentration on the product qualities and to determine the the best treatment in making a good quality adible film and acceptable by the consumer. This research used completely randomized design in factorial patern with two factors. The first factor was cassava starch concentration (25%, 35% and 45%) and the second factor was glycerol concentration (20 %, 15% and 10). The data were analyzed by Analysis of Variance (Anova) and Duncan’s Multiple Range Test to detect the difference between the treatment. The best treatment was 25% cassava starch addition and 10% glycerol concentration which produced edible film which had moisture content of 21.16%, thickness of 0.023 mm, tensile strength of 1.900 N, elasticity of 14.223%, and vapor transmission rate of 116.963 g/m2/24 hours. So the production of edible film from papaya skin pectin was potential to be developed.

  1. A Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients.

    Science.gov (United States)

    Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A

    2016-01-01

    Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.

  2. Angular multiplexing holograms of four images recorded on photopolymer films with recording-film-thickness-dependent holographic characteristics

    Science.gov (United States)

    Osabe, Keiichi; Kawai, Kotaro

    2017-03-01

    In this study, angular multiplexing hologram recording photopolymer films were studied experimentally. The films contained acrylamide as a monomer, eosin Y as a sensitizer, and triethanolamine as a promoter in a polyvinyl alcohol matrix. In order to determine the appropriate thickness of the photopolymer films for angular multiplexing, photopolymer films with thicknesses of 29-503 μm were exposed to two intersecting beams of a YVO laser at a wavelength of 532 nm to form a holographic grating with a spatial frequency of 653 line/mm. The diffraction efficiencies as a function of the incident angle of reconstruction were measured. A narrow angular bandwidth and high diffraction efficiency are required for angular multiplexing; hence, we define the Q value, which is the diffraction efficiency divided by half the bandwidth. The Q value of the films depended on the thickness of the films, and was calculated based on the measured diffraction efficiencies. The Q value of a 297-μm-thick film was the highest of the all films. Therefore, the angular multiplexing experiments were conducted using 300-μm-thick films. In the angular multiplexing experiments, the object beam transmitted by a square aperture was focused by a Fourier transform lens and interfered with a reference beam. The maximum order of angular multiplexing was four. The signal intensity that corresponds to the squared-aperture transmission and the noise intensity that corresponds to transmission without the square aperture were measured. The signal intensities decreased as the order of angular multiplexing increased, and the noise intensities were not dependent on the order of angular multiplexing.

  3. Blockbuster genres in Danish independent film

    DEFF Research Database (Denmark)

    Hansen, Kim Toft

    2013-01-01

    is a certain reluctance towards supporting specific international blockbuster genres such as horror, the gangster drama and action film. Throughout the past decade, Danish independent cinema – motivated by for instance the alternative film school Super16 and self-governing film-milieus around Denmark – has...... genres and styles in the search for what is missing in Danish cinema. This works for some directors, principally, by directly reacting against the institutional and economic dominance and protectionism of primarily The Danish Film Institute. Indirectly, the some of the filmmakers seem to react against...... ‘what is allowed’ in Danish film culture. Thus, they actually define themselves as being non-mainstream by focussing on international mainstream genres. By way of examples from the Danish indie scene and interviews with noteworthy indie filmmakers, this article draws attention to a still fairly...

  4. Influencing Factors and Simplified Model of Film Hole Irrigation

    Directory of Open Access Journals (Sweden)

    Yi-Bo Li

    2017-07-01

    Full Text Available Film hole irrigation is an advanced low-cost and high-efficiency irrigation method, which can improve water conservation and water use efficiency. Given its various advantages and potential applications, we conducted a laboratory study to investigate the effects of soil texture, bulk density, initial soil moisture, irrigation depth, opening ratio (ρ, film hole diameter (D, and spacing on cumulative infiltration using SWMS-2D. We then proposed a simplified model based on the Kostiakov model for infiltration estimation. Error analyses indicated SWMS-2D to be suitable for infiltration simulation of film hole irrigation. Additional SWMS-2D-based investigations indicated that, for a certain soil, initial soil moisture and irrigation depth had the weakest effects on cumulative infiltration, whereas ρ and D had the strongest effects on cumulative infiltration. A simplified model with ρ and D was further established, and its use was then expanded to different soils. Verification based on seven soil types indicated that the established simplified double-factor model effectively estimates cumulative infiltration for film hole irrigation, with a small mean average error of 0.141–2.299 mm, a root mean square error of 0.177–2.722 mm, a percent bias of −2.131–1.479%, and a large Nash–Sutcliffe coefficient that is close to 1.0.

  5. On bistable states retention in ferroelectric Langmuir-Blodgett films

    Science.gov (United States)

    Geivandov, A. R.; Palto, S. P.; Yudin, S. G.; Fridkin, V. M.; Blinov, L. M.; Ducharme, S.

    2003-08-01

    A new insight into the nature of ferroelectricity is emerging from the study of ultra-thin ferroelectric films prepared of poly(vinylidene fluoride with trifluoroethylene) copolymer using Langmuir-Blodgett (LB) technique. Unique properties of these films indicate the existence of two-dimensional ferroelectricity. The retention of two polarized states in ferroelectric polymer LB films is studied using nonlinear dielectric spectroscopy. The technique is based on phase sensitive measurements of nonlinear dielectric spectroscopy. The amplitude of the current response at the 2nd harmonic of the applied voltage is proportional to the magnitude of the remnant polarization, while its phase gives the sign. We have found that 10 - 20 mm thick LB films can show fast switching time and long retention of the two polarized states. Nevertheless, LB films show a pronounced asymmetry in switching to the opposite states. Possible mechanisms of such behavior are discussed.

  6. Microporous polyurethane-acrylamide film cured by electron beam irradiation

    International Nuclear Information System (INIS)

    Ando, Masayuki; Goto, Takakazu; Tsuchiya, Mitsuru; Uryu, Toshiyuki

    1988-01-01

    The morphology and aggregation structure of electron beam (EB)-cured microporous polyurethane-acrylamide film was investigated. The urethane-acrylamide prepolymer was synthesized by the reaction of poly(butylene adipate)diol, diphenylmethane diisocyanate, and N-(hydroxymethyl)acrylamide. It was found from scanning electron microscopy that the urethane-acrylamide film, which was prepared by using a methyl ethyl ketone and dimethylformamide (3:1 v/v) mixture as casting solvent, had a microporous structure with pore size of several micrometers, and that the morphology was fixed by EB irradiation. The pore volume of the EB-cured microporous film was determined to be about 460 mm 3 g -1 by mercury porosimetry. The micropores were not destroyed even after immersing in solvent, possibly because the cured film had high crystallinity and dense crosslinking. Moreover, it was found by X-ray photelectron spectroscopy that terminal portions of urethane-acrylamide were localized at the film surface. (author)

  7. Fabrication of a thin-film capacitive force sensor array for tactile feedback in robotic surgery.

    Science.gov (United States)

    Paydar, Omeed H; Wottawa, Christopher R; Fan, Richard E; Dutson, Erik P; Grundfest, Warren S; Culjat, Martin O; Candler, Rob N

    2012-01-01

    Although surgical robotic systems provide several advantages over conventional minimally invasive techniques, they are limited by a lack of tactile feedback. Recent research efforts have successfully integrated tactile feedback components onto surgical robotic systems, and have shown significant improvement to surgical control during in vitro experiments. The primary barrier to the adoption of tactile feedback in clinical use is the unavailability of suitable force sensing technologies. This paper describes the design and fabrication of a thin-film capacitive force sensor array that is intended for integration with tactile feedback systems. This capacitive force sensing technology could provide precise, high-sensitivity, real-time responses to both static and dynamic loads. Capacitive force sensors were designed to operate with optimal sensitivity and dynamic range in the range of forces typical in minimally invasive surgery (0-40 N). Initial results validate the fabrication of these capacitive force-sensing arrays. We report 16.3 pF and 146 pF for 1-mm(2) and 9-mm(2) capacitive areas, respectively, whose values are within 3% of theoretical predictions.

  8. 16 CFR 1507.12 - Multiple-tube fireworks devices.

    Science.gov (United States)

    2010-01-01

    ... Section 1507.12 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT... the inclined plane (not including the portion of the plane below the mechanical stop) shall be at... equivalent instrument. The mechanical stop on the inclined plane shall be 1/16 inches (1.6 mm) in height and...

  9. Approaching the event horizon: 1.3mmλ VLBI of SgrA*

    International Nuclear Information System (INIS)

    Doeleman, Sheperd

    2008-01-01

    Advances in VLBI instrumentation now allow wideband recording that significantly increases the sensitivity of short wavelength VLBI observations. Observations of the super-massive black hole candidate at the center of the Milky Way, SgrA*, with short wavelength VLBI reduces the scattering effects of the intervening interstellar medium, allowing observations with angular resolution comparable to the apparent size of the event horizon of the putative black hole. Observations in April 2007 at a wavelength of 1.3mm on a three station VLBI array have now confirmed structure in SgrA* on scales of just a few Schwarzschild radii. When modeled as a circular Gaussian, the fitted diameter of SgrA* is 37 μas (+16,-10; 3σ), which is smaller than the expected apparent size of the event horizon of the Galactic Center black hole. These observations demonstrate that mm/sub-mm VLBI is poised to open a new window onto the study of black hole physics via high angular resolution observations of the Galactic Center.

  10. Droplet-Wall/Film Impact in IC Engine Applications

    Science.gov (United States)

    2017-08-14

    Report: Droplet-Wall/ Film Impact in IC Engine Applications (ARO Topic 1.4.1 under ARO’s Dr. Ralph A. Anthenien) The views, opinions and/or findings...Participants: RPPR Final Report as of 12-Oct-2017 Agreement Number: W911NF-16-1-0449 Organization: Princeton University Title: Droplet-Wall/ Film Impact...droplets impacting a wet surface under various film thickness, which plays a critical role in controlling the efficiency of applications such as those

  11. Suberin fatty acids isolated from outer birch bark improve moisture barrier properties of cellulose ether films intended for tablet coatings.

    Science.gov (United States)

    Heinämäki, Jyrki; Halenius, Anna; Paavo, Maaja; Alakurtti, Sami; Pitkänen, Pauliina; Pirttimaa, Minni; Paaver, Urve; Kirsimäe, Kalle; Kogermann, Karin; Yliruusi, Jouko

    2015-07-15

    We showed that the addition of suberin fatty acids (SFAs) even at small concentrations significantly improves the water vapor barrier properties of hydroxypropyl methylcellulose (HPMC) films. SFAs were isolated from the outer birch bark using extractive hydrolysis. The effects of SFAs on the film formation of aqueous HPMC were investigated with free films plasticized with polyethylene glycol (PEG 400). Special attention was paid on the physical solid-state, moisture barrier and mechanical stress-strain properties of films intended for tablet film coatings. Topography and surface morphology, glass transition temperature (Tg), tensile strength, Young's modulus, and water vapor permeation (WVP) of films were studied. The addition of SFAs lowered the Tg of films suggesting partial enhancement in film plasticization. The WVP of films decreased with increasing SFAs concentration up to 15% (calculated as a % w/w from a polymer weight). The WVP value for a non-suberized reference film and suberized film plasticized with PEG 400 was 2.13×10(-6) and 0.69[×10(-6) g/(mm(2)×h)×mm/Pa], respectively. The addition of SFAs impaired the mechanical stress-strain properties of HPMC films by reducing the deformation capacity of film. In conclusion, the film properties and performance of aqueous HPMC can be modified by including SFAs in the films. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Plasma CVD reactor with two-microwave oscillators for diamond film synthesis

    International Nuclear Information System (INIS)

    Nagatsu, M.; Miyake, M.; Maeda, J.

    2006-01-01

    In this study, we present the experimental results of a new type of microwave plasma CVD system, where two of 1.5 kW microwave sources were used for enlarging the plasma discharge and the diamond film growth. One of the microwave oscillators was used to produce the microwave plasma as in the conventional microwave plasma CVD device, while the second one was used to enlarge the plasma by introducing microwave from the launcher mounted at the substrate stage. We demonstrated the enlargement of plasma discharge area from 60 mm to 100 mm in diameter by using the two-microwave oscillators system. Characteristics of diamond films deposited using H 2 /CH 4 plasmas were also investigated using a scanning electron microscope (SEM) and Raman spectroscopy

  13. The critical mission of glycine as a surfactant in the improvement of structural, morphological and optoelectronic features of CdO films

    Science.gov (United States)

    Aydin, Raşit

    2018-05-01

    The main aim of this study is to examine the effect of glycine as a surfactant agent on the physical properties of CdO films. For this purpose nanostructured CdO films with and without different glycine aggregations (0.5, 1.0 and 2.0 M %) were synthesized on glass bases by SILAR technique. The morphological, structural and optical characteristics of these films have been investigated using MM, SEM, XRD and UV-visible spectroscopy respectively. The MM results showed homogeneous and smooth all films. The SEM graphs showed that by using different glycine concentrations as surfactant, the particle thickness decreased from 366.25 nm to 241.10 nm. XRD results showed that the all CdO films with glycine display a (111) and (200) preferential orientations similar to that of the CdO film without glycine. The direct band gap energy of these films is found to increase from 2.05 to 2.35 eV with increasing the glycine concentration in the bath solution.

  14. Development of Flexible, Free-Standing, Thin Films for Additive Manufacturing and Localized Energy Generation

    Science.gov (United States)

    2015-08-10

    does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. Texas Technical University Box 41035 349...upon reaction. All films were cast at a thickness of 1 mm with constant volume percent solids to ensure consistent rheological properties. The films...2005); 10.1063/1.2058175 Local dynamic mechanical properties in model free-standing polymer thin films J. Chem. Phys. 122, 144712 (2005); 10.1063

  15. Influence of cement film thickness on the retention of implant-retained crowns.

    Science.gov (United States)

    Mehl, Christian; Harder, Sönke; Steiner, Martin; Vollrath, Oliver; Kern, Matthias

    2013-12-01

    The main goal of this study was to establish a new, high precision procedure to evaluate the influence of cement film thickness on the retention of cemented implant-retained crowns. Ninety-six tapered titanium abutments (6° taper, 4.3 mm diameter, Camlog) were shortened to 4 mm. Computer-aided design was used to design the crowns, and selective laser sintering, using a cobalt-chromium alloy, was used to produce the crowns. This method used a focused high-energy laser beam to fuse a localized region of metal powder to build up the crowns gradually. Before cementing, preset cement film thicknesses of 15, 50, 80, or 110 μm were established. Glass ionomer, polycarboxylate, or resin cements were used for cementation. After 3 days storage in demineralized water, the retention of the crowns was measured in tension using a universal testing machine. The cement film thicknesses could be achieved with a high level of precision. Interactions between the factors cement and cement film thickness could be found (p ≤ 0.001). For all cements, crown retention decreased significantly between a cement film thickness of 15 and 50 μm (p ≤ 0.001). At 15 μm cement film thickness, the resin cement was the most retentive cement, followed by the polycarboxylate and then the glass ionomer cement (p ≤ 0.05). The results suggest that cement film thickness has an influence on the retentive strength of cemented implant-retained crowns. © 2013 by the American College of Prosthodontists.

  16. SU-E-T-104: Development of 3 Dimensional Dosimetry System for Gamma Knife

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K; Kwak, J; Cho, B; Lee, D; Ahn, S [Asan Medical Center, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The aim of this study was to develop a new 3 dimensional dosimetry system to verify the dosimetric accuracy of Leksell Gamma Knife-Perfexion™ (LGK) (Elekta, Norcross, GA). Methods: We designed and manufactured a lightweight dosimetry instrument to be equipped with the head frame to LGK. It consists of a head phantom, a scintillator, a CCD camera and a step motor. The 10×10 cm2 sheet of Gd2O3;Tb phosphor or Gafchromic EBT3 film was located at the center of the 16 cm diameter hemispherical PMMA, the head phantom. The additional backscatter compensating material of 1 cm thick PMMA plate was placed downstream of the phosphor sheet. The backscatter plate was transparent for scintillation lights to reach the CCD camera with 1200×1200 pixels by 5.2 um pitch. With This equipment, 300 images with 0.2 mm of slice gap were acquired under three collimator setups (4mm, 8mm and 16mm), respectively. The 2D projected doses from 3D distributions were compared with the exposured film dose. Results: As all doses normalized by the maximum dose value in 16 mm setup, the relative differences between the equipment dose and film dose were 0.2% for 4mm collimator and 0.5% for 8mm. The acquisition of 300 images by the equipment took less than 3 minutes. Conclusion: The new equipment was verified to be a good substitute to radiochromic film, with which required more time and resources. Especially, the new methods was considered to provide much convenient and faster solution in the 3D dose acquisition for LGK.

  17. Studying gas-sheared liquid film in horizontal rectangular duct with laser-induced fluorescence technique

    Science.gov (United States)

    Cherdantsev, Andrey; Hann, David; Azzopardi, Barry

    2013-11-01

    High-speed LIF-technique is applied to study gas-sheared liquid film in horizontal rectangular duct with 161 mm width. Instantaneous distributions of film thickness resolved in both longitudinal and transverse coordinates were obtained with a frequency of 10 kHz and spatial resolution from 0.125 mm to 0.04 mm. Processes of generation of fast and slow ripples by disturbance waves are the same as described in literature for downwards annular pipe flow. Disturbance waves are often localized by transverse coordinate and may have curved or slanted fronts. Fast ripples, covering disturbance waves, are typically horseshoe-shaped and placed in staggered order. Their characteristic transverse size is of order 1 cm and it decreases with gas velocity. Entrainment of liquid from film surface can also be visualized. Mechanisms of ripple disruption, known as ``bag break-up'' and ``ligament break-up,'' were observed. Both mechanisms may occur on the same disturbance waves. Various scenarios of droplet deposition on the liquid film are observed, including the impact, slow sinking and bouncing, characterized by different outcome of secondary droplets or entrapped bubbles. Number and size of bubbles increase greatly inside the disturbance waves. Both quantities increase with gas and liquid flow rates. EPSRC Programme Grant MEMPHIS (EP/K003976/1), and Roll-Royce UTC (Nottingham, for access to flow facility).

  18. The absorption of thermal radiation by water films

    International Nuclear Information System (INIS)

    Pearson, K.G.; Elliott, D.

    1977-04-01

    Except at the shortest wavelengths (i.e. <2μm) liquid water is relatively opaque to thermal radiation. It is also a poor reflector, reflecting back only about 2% of normal incident radiation. It is shown that when radiation falls on a plane water surface from a parallel heated surface about 93.5% of the incident radiation enters the surface, the remaining 6.5% being reflected back to the source. It is also shown that, for source temperatures up to the maximum of interest in reactor safety studies, a large fraction of the thermal radiation which enters the water is absorbed on passing through a distance approaching 0.5 mm. Since liquid water films of such thickness can be expected to exist on the pressure tubes of an SGHWR following a loss of coolant accident it follows that, irrespective of the condition of the pressure tube wall, the absorptivity of the pressure tubes will in effect be about 0.9. Data are presented for experiments performed to determine the absorptivity of water films on a polished surface whose dry absorptivity was measured to be 0.18. The presence of the water film, of estimated thickness 0.3 mm, increased the absorptivity of the surface to a value close to unity. (author)

  19. Predicting Emotional Responses to Horror Films from Cue-Specific Affect.

    Science.gov (United States)

    Neuendorf, Kimberly A.; Sparks, Glenn G.

    1988-01-01

    Assesses individuals' fear and enjoyment reactions to horror films, applying theories of cognition and affect that predict emotional responses to a stimulus on the basis of prior affect toward specific cues included in that stimulus. (MM)

  20. Nanoporous cerium oxide thin film for glucose biosensor.

    Science.gov (United States)

    Saha, Shibu; Arya, Sunil K; Singh, S P; Sreenivas, K; Malhotra, B D; Gupta, Vinay

    2009-03-15

    Nanoporous cerium oxide (CeO(2)) thin film deposited onto platinum (Pt) coated glass plate using pulsed laser deposition (PLD) has been utilized for immobilization of glucose oxidase (GOx). Atomic force microscopy studies reveal the formation of nanoporous surface morphology of CeO(2) thin film. Response studies carried out using differential pulsed voltammetry (DPV) and optical measurements show that the GOx/CeO(2)/Pt bio-electrode shows linearity in the range of 25-300 mg/dl of glucose concentration. The low value of Michaelis-Menten constant (1.01 mM) indicates enhanced enzyme affinity of GOx to glucose. The observed results show promising application of the nanoporous CeO(2) thin film for glucose sensing application without any surface functionalization or mediator.

  1. Magnetic properties changes of MnAs thin films irradiated with highly charged ions

    OpenAIRE

    Trassinelli , Martino; Gafton , V.; Eddrief , Mahmoud; Etgens , Victor H.; Hidki , S.; Lacaze , Emmanuelle; Lamour , Emily; Luo , X.; Marangolo , Massimiliano; Merot , Jacques; Prigent , Christophe; Reuschl , Regina; Rozet , Jean-Pierre; Steydli , S.; Vernhet , Dominique

    2013-01-01

    International audience; We present the first investigation on the effect of highly charged ion bombardment on a manganese arsenide thin film. The MnAs films, 150~nm thick, are irradiated with 90 keV Ne$^{9+}$ ions with a dose varying from $1.6\\times10^{12}$ to $1.6\\times10^{15}$~ions/cm$^2$. The structural and magnetic properties of the film after irradiation are investigated using different techniques, namely, X-ray diffraction, magneto-optic Kerr effect and magnetic force microscope. Prelim...

  2. Microcoaxial cataract surgery outcomes: comparison of 1.8 mm system and 2.2 mm system.

    Science.gov (United States)

    Lee, Kyung-Min; Kwon, Hyung-Goo; Joo, Choun-Ki

    2009-05-01

    To compare clinical outcomes of a 1.8 mm and a 2.2 mm microcoaxial cataract surgery system. Department of Ophthalmology and Visual Science, Kangnam St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea. In a prospective study, eyes were randomly selected to have phacoemulsification using a Stellaris system or an Intrepid Infiniti system. The initial incision size was 1.8 mm and 2.2 mm, respectively. Measured intraoperative parameters included phacoemulsification time, mean cumulative dissipated ultrasound energy (CDE), change in incision size at each step of surgery, and total volume of balanced salt solution (BSS) used. The best corrected visual acuity (BCVA), corneal astigmatism, corneal thickness, and endothelial cell count were evaluated preoperatively and postoperatively. The study evaluated 86 eyes of 78 patients (43 eyes in each group). There were no significant differences in postoperative BCVA, surgically induced astigmatism, or amount of BSS used between the 2 systems (P >.05). However, for high-density cataracts, the 1.8 mm group had a greater change between the initial incision size and the incision size after phacoemulsification (P = .019, nuclear opalescence [NO] NO3; P = .001, NO4), a longer phacoemulsification time (P = .013, NO3), greater mean CDE (P = .005, NO3; P = .001, NO4), and greater corneal endothelial cell loss (P = .003, NO4). Both systems were safe and effective in microcoaxial phacoemulsification. The 1.8 mm system performed better with cortical-type cataract and the 2.2 mm system, with high-density nuclear-type cataract.

  3. Laser Based Color Film Recorder System With GaAs Microlaser

    Science.gov (United States)

    Difrancesco, David J.

    1989-07-01

    In 1984 Pixar's research and development group built and applied to the motion-picture arts at Lucasfilm's ILM facility a three color laser based film scanner/recorder system. The digital film printer is capable of reading and writing 35mm film formats on a variety of film stocks. The system has been used in award-winning special-effects work, and has been operated in a normal production environment since that time. The primary objective was to develop a full color high resolution system, free from scan artifacts, enabling traditionally photographed motion-picture film to be inter-cut with digital raster image photography. Its use is applied to the art of blue-screen traveling-matte cinematography for motion pic-ture special effects. The system was designed using the Pixar Image Computer and conventional gas laser technology as the illumination source. This paper will discuss recent experimental work in the application of GaAs microlaser technology to a digital film printing system of the future.

  4. 2D Organic-Inorganic Hybrid Thin Films for Flexible UV-Visible Photodetectors

    KAUST Repository

    Velusamy, Dhinesh Babu

    2017-02-13

    Flexible 2D inorganic MoS and organic g-CN hybrid thin film photodetectors with tunable composition and photodetection properties are developed using simple solution processing. The hybrid films fabricated on paper substrate show broadband photodetection suitable for both UV and visible light with good responsivity, detectivity, and reliable and rapid photoswitching characteristics comparable to monolayer devices. This excellent performance is retained even after the films are severely deformed at a bending radius of ≈2 mm for hundreds of cycles. The detailed charge transfer and separation processes at the interface between the 2D materials in the hybrid films are confirmed by femtosecond transient absorption spectroscopy with broadband capability.

  5. Film boiling heat transfer in liquid helium

    International Nuclear Information System (INIS)

    Inai, Nobuhiko

    1979-01-01

    The experimental data on the film boiling heat transfer in liquid helium are required for investigating the stability of superconducting wires. On the other hand, liquid helium has the extremely different physical properties as compared with the liquids at normal temperature such as water. In this study, the experiments on pool boiling were carried out, using the horizontal top surface of a 20 mm diameter copper cylinder in liquid helium. For observing individual bubbles, the experiments on film boiling from a horizontal platinum wire were performed separately in liquid nitrogen and liquid helium, and photographs of floating-away bubbles were taken. The author pointed out the considerable upward shift of the boiling curve near the least heat flux point in film boiling from the one given by the Berenson's equation which has been said to agree comparatively well with the data on the film boiling of the liquids at normal temperature, and the reason was investigated. Consequently, a model for film boiling heat transfer was presented. Also one equation expressing the film boiling at low heat flux for low temperature liquids was proposed. It represents well the tendency to shift from Berenson's equation of the experimental data on film boiling at the least heat flux point for liquid helium, liquid nitrogen and water having extremely different physical properties. Some discussions are added at the end of the paper. (Wakatsuki, Y.)

  6. Preparation of flexible and heat-resisting conductive transparent film by the pyrosol process

    International Nuclear Information System (INIS)

    Usami, Hisanao; Nakasa, Akihiko; Adachi, Mami; Suzuki, Eiji; Fujimatsu, Hitoshi; Ohashi, Tatsuya; Yamada, Shigeo; Tsugita, Kouhei; Taniguchi, Yoshio

    2006-01-01

    A pyrosol process was successfully applied for the preparation of a flexible, conductive, and transparent inorganic film, a tin-doped indium oxide (ITO) film lined with a thin mica layer. This flexible heat-resistant ITO-mica film exhibited high conductivity and transparency, comparable to ITO deposited on glass substrate. The minimum radius of bending for the film, without any recognizable change in the conductivity and appearance, was 8 mm. The ITO deposited on mica showed a large (222) diffraction peak with a smaller (400) peak, in contrast to ITO deposited with (400) orientation on an ordinary glass substrate. Using the ITO-mica film, a prototype model of a flexible organic light emitting diode was fabricated

  7. Function and application of ultra thin films

    Energy Technology Data Exchange (ETDEWEB)

    Sasabe, Hiroyuki

    1988-02-01

    A film 10-100mm thick which is strong dynamically to some extent and has possibility to manifest fuctions of high degree different from the nature extrapolated from the normal thin film is called an ultra thin film. As an example of its concrete application, there is an electro-luminescence element which is made by laminating 5 layers of LB films of poly-L-phenylalanine on a n-GaP and has vapor-deposited gold electrodes. When voltage of 5V is imposed to it, light emission of 565nm can be observed and the emission efficiency of 2% is obtained. Besides, it has an excellent stability through the lapse of time. There is also a junction element and the ion concentration injected into macromolecule films of this element has a Gaussian distribution from the surface towards the direction of depth. Accordingly, the most active domain in terms of semiconductor as the result of doping is the location in the neighborhood of the peak. Furthermore, a photo memory is also proposed. It is applied to the artificial hemoglobine which is made of LB films, suggesting the feasibility of creating the artificial protein capable of functioning in the conditions in which the natural protein is unable to function. (5 figs, 1 tab, 7 refs)

  8. A Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Iman M. Eissa

    2016-01-01

    Full Text Available Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P=0.002, with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.

  9. Simultaneous measurement of dynamic force and spatial thin film thickness between deformable and solid surfaces by integrated thin liquid film force apparatus.

    Science.gov (United States)

    Zhang, Xurui; Tchoukov, Plamen; Manica, Rogerio; Wang, Louxiang; Liu, Qingxia; Xu, Zhenghe

    2016-11-09

    Interactions involving deformable surfaces reveal a number of distinguishing physicochemical characteristics that do not exist in interactions between rigid solid surfaces. A unique fully custom-designed instrument, referred to as integrated thin liquid film force apparatus (ITLFFA), was developed to study the interactions between one deformable and one solid surface in liquid. Incorporating a bimorph force sensor with interferometry, this device allows for the simultaneous measurement of the time-dependent interaction force and the corresponding spatiotemporal film thickness of the intervening liquid film. The ITLFFA possesses the specific feature of conducting measurement under a wide range of hydrodynamic conditions, with a displacement velocity of deformable surfaces ranging from 2 μm s -1 to 50 mm s -1 . Equipped with a high speed camera, the results of a bubble interacting with hydrophilic and partially hydrophobic surfaces in aqueous solutions indicated that ITLFFA can provide information on interaction forces and thin liquid film drainage dynamics not only in a stable film but also in films of the quick rupture process. The weak interaction force was extracted from a measured film profile. Because of its well-characterized experimental conditions, ITLFFA permits the accurate and quantitative comparison/validation between measured and calculated interaction forces and temporal film profiles.

  10. Initial Growth Process of Magnetron Sputtering 321 Stainless Steel Films Observed by Afm

    Science.gov (United States)

    Jin, Yongzhong; Wu, Wei; Liu, Dongliang; Chen, Jian; Sun, Yali

    To investigate the initial morphological evolution of 321 stainless steel (SS) films, we examined the effect of sputtering time on the morphology of 321 SS film. In this study, a group of samples were prepared at nine different sputtering times within 20 s using radio-frequency (r.f.) magnetron sputtering and characterized by atomic force microscopy (AFM). Only globular-like grains were formed on mica substrates within 6 s, whose average grain size is ~ 21-44 nm. Meanwhile, few grains with larger size are subject to settle at the defect sites of mica substrates. At 8 s, we found large columnar crystallites with the average grain size of 61 nm. From 10 to 14 s, islands grew continuously and coalesced in order to form an interconnected structure containing irregular channels or grooves, with a depth of ~ 3.5-5 nm. Up to 16 s, a nearly continuous film was formed and some new globular-like grains were again present on the film. Study of the AFM image at 20 s suggests that the watercolor masking method designed by us is an effective method, by which we can prepare thin films with steps for the measurement of the thickness of continuous thin films. It is also found that the coverage rate of films increases with the increase in sputtering time (from 2 to 16 s). On the other hand, the increase in root mean square (RMS) roughness is much more significant from 6 to 10 s, and there is a maximum value, 2.81 nm at 10 s due to more islands during deposition. However, RMS roughness decreases with the decrease in length and width of channels or grooves from 10 to 16 s. Especially, a lower RMS roughness of 0.73 nm occurs at 16 s, because of the continuous film produced with a large coverage rate of 98.43%.

  11. Antimicrobial Activity of Nisin and Natamycin Incorporated Sodium Caseinate Extrusion-Blown Films: A Comparative Study with Heat-Pressed/Solution Cast Films.

    Science.gov (United States)

    Colak, Basak Yilin; Peynichou, Pierre; Galland, Sophie; Oulahal, Nadia; Prochazka, Frédéric; Degraeve, Pascal

    2016-05-01

    Antimicrobial edible films based on sodium caseinate, glycerol, and 2 food preservatives (nisin or natamycin) were prepared by classical thermomechanical processes. Food preservatives were compounded (at 65 °C for 2.5 min) with sodium caseinate in a twin-screw extruder. Anti-Listeria activity assays revealed a partial inactivation of nisin following compounding. Thermoplastic pellets containing food preservatives were then used to manufacture films either by blown-film extrusion process or by heat-press. After 24 h of incubation on agar plates, the diameters of K. rhizophila growth inhibition zones around nisin-incorporated films prepared by solution casting (control), extrusion blowing or heat pressing at 80 °C for 7 min of nisin-containing pellets were 15.5 ± 0.9, 9.8 ± 0.2, and 8.6 ± 1.0 mm, respectively. Since heat-pressing for 7 min at 80 °C of nisin-incorporated pellets did not further inactivate nisin, this indicates that nisin inactivation during extrusion-blowing was limited. Moreover, the lower diameter of the K. rhizophila growth inhibition zone around films prepared with nisin-containing pellets compared to that observed around films directly prepared by solution casting confirms that nisin inactivation mainly occurred during the compounding step. Natamycin-containing thermoplastic films inhibited Aspergillus niger growth; however, by contrast with nisin-containing films, heat-pressed films had higher inhibition zone diameters than blown films, therefore suggesting a partial inactivation of natamycin during extrusion-blowing. © 2016 Institute of Food Technologists®

  12. Phase, current, absorbance, and photoluminescence of double and triple metal ion-doped synthetic and salmon DNA thin films

    Science.gov (United States)

    Chopade, Prathamesh; Reddy Dugasani, Sreekantha; Reddy Kesama, Mallikarjuna; Yoo, Sanghyun; Gnapareddy, Bramaramba; Lee, Yun Woo; Jeon, Sohee; Jeong, Jun-Ho; Park, Sung Ha

    2017-10-01

    We fabricated synthetic double-crossover (DX) DNA lattices and natural salmon DNA (SDNA) thin films, doped with 3 combinations of double divalent metal ions (M2+)-doped groups (Co2+-Ni2+, Cu2+-Co2+, and Cu2+-Ni2+) and single combination of a triple M2+-doped group (Cu2+-Ni2+-Co2+) at various concentrations of M2+ ([M2+]). We evaluated the optimum concentration of M2+ ([M2+]O) (the phase of M2+-doped DX DNA lattices changed from crystalline (up to ([M2+]O) to amorphous (above [M2+]O)) and measured the current, absorbance, and photoluminescent characteristics of multiple M2+-doped SDNA thin films. Phase transitions (visualized in phase diagrams theoretically as well as experimentally) from crystalline to amorphous for double (Co2+-Ni2+, Cu2+-Co2+, and Cu2+-Ni2+) and triple (Cu2+-Ni2+-Co2+) dopings occurred between 0.8 mM and 1.0 mM of Ni2+ at a fixed 0.5 mM of Co2+, between 0.6 mM and 0.8 mM of Co2+ at a fixed 3.0 mM of Cu2+, between 0.6 mM and 0.8 mM of Ni2+ at a fixed 3.0 mM of Cu2+, and between 0.6 mM and 0.8 mM of Co2+ at fixed 2.0 mM of Cu2+ and 0.8 mM of Ni2+, respectively. The overall behavior of the current and photoluminescence showed increments as increasing [M2+] up to [M2+]O, then decrements with further increasing [M2+]. On the other hand, absorbance at 260 nm showed the opposite behavior. Multiple M2+-doped DNA thin films can be used in specific devices and sensors with enhanced optoelectric characteristics and tunable multi-functionalities.

  13. Oral transmucosal delivery of domperidone from immediate release films produced via hot-melt extrusion technology.

    Science.gov (United States)

    Palem, Chinna Reddy; Kumar Battu, Sunil; Maddineni, Sindhuri; Gannu, Ramesh; Repka, Michael A; Yamsani, Madhusudan Rao

    2013-02-01

    The objective of the study was to prepare and characterize the domperidone (DOM) hot-melt extruded (HME) buccal films by both in vitro and in vivo techniques. The HME film formulations contained PEO N10 and/or its combination with HPMC E5 LV or Eudragit RL100 as polymeric carriers, and PEG3350 as a plasticizer. The blends were co-processed at a screw speed of 50 rpm with the barrel temperatures ranging from 120-160°C utilizing a bench top co-rotating twin-screw hot-melt extruder using a transverse-slit die. The HME films were evaluated for drug content, drug excipient interaction, in vitro drug release, mechanical properties, in vivo residence time, in vitro bioadhesion, swelling and erosion, ex vivo permeation from HME films and the selected optimal formulation was subjected for bioavailability studies in healthy human volunteers. The extruded films demonstrated no drug excipient interaction and excellent content uniformity. The selected HME film formulation (DOM2) exhibited a tensile strength (0.72 Kg/mm(2)), elongation at break (28.4% mm(2)), in vivo residence time (120 min), peak detachment force (1.55 N), work of adhesion (1.49 mJ), swelling index (210.2%), erosion (10.5%) and in vitro drug release of 84.8% in 2 h. Bioavailability from the optimized HME buccal films was 1.5 times higher than the oral dosage form and the results showed statistically significant (p buccal-adhesive films with improved bioavailability characteristics.

  14. Superhydrophilic SnO{sub 2} nanosheet-assembled film

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, Yoshitake, E-mail: masuda-y@aist.go.jp; Kato, Kazumi

    2013-10-01

    SnO{sub 2} films were fabricated on fluorine-doped tin oxide (FTO) substrates in aqueous solutions. The films of about 800 nm in thickness grew in the solutions containing SnF{sub 2} of 25 mM at 90 °C for 24 h. They consisted of nanosheets of about 5–10 nm in thickness and about 100–1600 nm in plane size. The films had gradient structure of nanosheets. Smaller nanosheets formed dense structures in a bottom area, while larger nanosheets formed porous structures in a surface area of the films. The SnO{sub 2} films showed higher transparency than bare FTO substrates in a visible light region of 470 to 850 nm. Decrease of reflectance increased transparency. The SnO{sub 2} films had superhydrophilic surfaces of static contact angle below 1°. Nanosheet-assembled structures contributed high hydrophilicity. The surfaces were further modified with light irradiation. High speed camera observation showed that spread speed of water was improved with the irradiation. Removal of surface adsorbed organic molecules and increase in the number of hydroxyl groups brought superhydrophilicity and high spread speed. - Highlights: ► SnO{sub 2} nanosheet films were prepared from aqueous solutions. ► The antireflective films showed superhydrophilicity. ► Crystal growth mechanism of the gradient structures is discussed.

  15. (MAA:EA) copolymer films

    Indian Academy of Sciences (India)

    2017-08-16

    Aug 16, 2017 ... behaviour. The interaction between oppositely charged poly- ... methods to improve the ionic conductivity, optical proper- ties, mechanical and ... liquid, filler and mixed salt systems [10,11]. Based on the ... multiple ways of preparing Cu2+ based polymer thin films. The Cu2+ ion ..... A broad and very strong.

  16. Liquid Film Diffusion on Reaction Rate in Submerged Biofilters

    DEFF Research Database (Denmark)

    Christiansen, Pia; Hollesen, Line; Harremoës, Poul

    1995-01-01

    Experiments were carried out in order to investigate the influence of liquid film diffusion on reaction rate in a submerged biofilter with denitrification and in order to compare with a theoretical study of the mass transfer coefficient. The experiments were carried out with varied flow, identified...... by the empty bed velocity of inflow and recirculation, respectively 1.3, 2.8, 5.6 and 10.9 m/h. The filter material consisted of 3 mm biostyren spheres. The results indicate that the influence of liquid film diffusion on reaction rate can be ignored....

  17. High performance batch production of LREBa2Cu3Oy using novel thin film Nd-123 seed

    International Nuclear Information System (INIS)

    Muralidhar, M.; Suzuki, K.; Fukumoto, Y.; Ishihara, A.; Tomita, M.

    2011-01-01

    A batch production for fabrication of LREBa 2 Cu 3 O y (LRE: Sm, Gd, NEG) 'LRE-123' pellets are developed in air and Ar-1% O 2 using a novel thin film Nd-123 seeds grown on MgO crystals. The SEM and XRD results conformed that the quality and orientation of the seed crystals are excellent. On the other hand, new seeds can withstand temperatures >1100 deg. C, as a result, the cold seeding process was applied even to grow Sm-123 material in Air. The trapped field observed in the best 45 mm single-grain puck of Gd-123 was in the range of 1.35 T and 0.35 T at 77.3 K and 87.3 K, respectively. The average trapped field at 77.3 K in the 24 mm diameter NEG-123 samples batch lies between 0.9 and 1 T. The maximum trapped field of 1.2 T was recorded at the sample surface. Further, the maximum trapped field of 0.23 T at 77 K was recorded in a sample with 16 mm diameter of Sm-123 with 3 mol% BaO 2 addition. As a result we made more then 130 single grain pucks within a couple of months. Taking advantage of the single grain batch processed material, we constructed self-made chilled levitation disk, which was used on the open day of railway technical research Institute. More then 150 children stood on the levitation disk and revel the experience of levitation. The present results prove that a high-performance good-quality class of LREBa 2 Cu 3 O y material can be made by using a novel thin film Nd-123 seeds.

  18. Treatment verification system in radiotherapy using a digital portal imaging device. Comparison with screen/film systems

    International Nuclear Information System (INIS)

    Nakata, Manabu; Komai, Yoshinori; Okada, Takashi; Fukumoto, Satoshi; Chadani, Kazuma; Nohara, Hiroki; Kazusa, Chudou.

    1994-01-01

    A digital portal imaging (DPI) system for megavoltage photon beams was installed recently in our department. The purpose of this study is to evaluate the image quality of this system. We have analyzed the following properties of the system; relationship between measured dose-rate and pixel values of the DPI, spatial resolution, detectability of low-contrast objects and setup errors. The results were compared with those of conventional screen-film systems. As a result, the relationship between the measured dose-rate and the pixel value of the DPI was found to be linear in the dose-rate range between 100 and 400 cGy/min. Spatial resolution was 1.25 and 0.5 mm for the DPI and the screen-film systems, respectively. The slope of the contrast-detail curves differed between the DPI and the screen-film systems, the contrast thresholds were 0.6 and 0.3% for the DPI and the screen-film systems, respectively. The detectability of a setup error of 1 mm and 2 mm for the DPI was lower than that by the screen-film systems, although the difference was not very significant. In conclusion, the image quality of the DPI at present time is slightly inferior to the conventional screen-film systems. However, notable advantages of the DPI system are that any positional changes in patients during irradiation can be detected very quickly, and that quantitative analysis of the setup variation can be obtained. The image quality of the DPI will be improved as the technology regarding advances. Therefore, this verification system using the DPI device, is expected to be used for clinical radiation therapy in the future. (author)

  19. Effect of Essential Oil of Attarasa Leaves (Litsea Cubeba Lour. Pers) on Physico-Mechanical and Microstructural Properties Of Breadfruit Starch-Alginate Edible Film

    International Nuclear Information System (INIS)

    Zuhra, C.F.; Kaban, J.; Marpongahtun; Erman Munir

    2013-01-01

    Research on preparation of edible film from breadfruit starch and alginate incorporated with essential oil of attarasa leaves (Litsea cubeba Lour Pers.) has been done. The film was evaluated of their thickness, tensile strength, elongation at break, water vapor transmission rate (WVTR) and microstructural properties by Scanning Electron Microscopy (SEM). Incorporation of the oil increased thickness of film from 0.033 mm to 0.036 mm, tensile strength from 32.8 to 37.0 MPa, elongation at break from 48.92 % to 50.43 % but water vapor transmission rate (WVTR) decreased from 142.9 g/ m 2 .hour to 120.3 g/ m 2 .hour. However SEM analysis showed that the surface microstructural of the film was more rough and solid compare with film without incorporation of essential oil. (author)

  20. Observations on dual-ended readout of 100 mm long LYSO crystals

    Energy Technology Data Exchange (ETDEWEB)

    Ur-Rehman, Fazal, E-mail: Fazal@physics.umanitoba.ca [Department of Physics and Astronomy, University of Manitoba, Winnipeg (Canada); McIntosh, Bryan [Department of Physics and Astronomy, University of Manitoba, Winnipeg (Canada); Goertzen, Andrew L. [Department of Physics and Astronomy, University of Manitoba, Winnipeg (Canada); Department of Radiology, University of Manitoba, Winnipeg (Canada)

    2011-10-01

    We are investigating using dual-ended readout of axially oriented long thin scintillator crystals in detectors for a compact geometry, small ring diameter animal PET system. The axial position of interaction is determined from the light sharing between two photodetectors at opposite ends of the crystal. We examine the light output, energy resolution and axial spatial resolution of 1.5-5x2x100 mm{sup 3} polished LYSO crystals by irradiating with an electronically collimated beam of 511 keV photons oriented perpendicular to the long axis and read out at either end by position sensitive photomultiplier tubes (PSPMTs). Three reflector materials, namely Teflon, 3 M enhanced specular reflector (ESR) and black paint are examined for the 2x2x100 mm{sup 3} crystal size. The light output increases and energy resolution improves with the crystal cross-section. Generally, the spatial resolution worsens with increase in crystal cross-section. For the 2x2x100 mm{sup 3} crystal size, the mean energy resolutions of the photopeak over the nine irradiation positions were 14.4{+-}0.4%, 16.0{+-}1.2% and 28.3{+-}2.1% with mean spatial resolutions of 7.0{+-}1.0, 9.4{+-}3.3 and 26.0{+-}5.0 mm using ESR, Teflon and black paint, respectively. ESR reflector gave the best light output, energy and axial spatial resolutions. These characterization results of PSPMT-based dual-ended long LYSO crystals will be useful in the design of detector modules for a highly compact geometry preclinical PET system using this detector technology.

  1. Development and surface characterization of a glucose biosensor based on a nanocolumnar ZnO film

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, A., E-mail: adriana.rodrigues@partner.kit.edu [Instituto de Física − UFRGS, P.O. Box 15051, 91501-970 Porto Alegre, RS (Brazil); Castegnaro, M.V. [Instituto de Física − UFRGS, P.O. Box 15051, 91501-970 Porto Alegre, RS (Brazil); Arguello, J.; Alves, M.C.M. [Instituto de Química − UFRGS, P.O. Box 15003, 91501-970 Porto Alegre, RS (Brazil); Morais, J., E-mail: jonder@if.ufrgs.br [Instituto de Física − UFRGS, P.O. Box 15051, 91501-970 Porto Alegre, RS (Brazil)

    2017-04-30

    Highlights: • Glucose biosensor based on self-assembled nanocolumnar ZnO deposited on stainless steel. • XPS applied to investigate the GOx immobilization on the ZnO nanocolumns surface. • Observable chemical shifts on O1s and Zn2p corroborates enzime immobilization. - Abstract: Highly oriented nanostructured ZnO films were grown on the surface of stainless steel plates (ZnO/SS) by chemical bath deposition (CBD). The films consisted of vertically aligned ZnO nanocolumns, ∼1 μm long and ∼80 nm wide, as observed by SEM (scanning electron microscopy) and FIB (focused ion beam). XRD (X-ray diffraction) confirmed the c-axis preferred orientation of the ZnO columns, which were functionalized with the glucose oxidase (GOx) enzyme into a biosensor of glucose. The electrochemical response studied by CV (cyclic voltammetry) proved that the biosensor was capable of detecting glucose from 1.5 up to 16 mM concentration range. XPS (X-ray photoelectron spectroscopy) analysis, excited with synchrotron radiation, probed the atom specific chemical environment at the electrode’s surface and shed some light on the nature of the ZnO-GOx interaction.

  2. Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

    International Nuclear Information System (INIS)

    Molon, Rafael Scaf; Morais Camillo, Juliana Aparecida Najarro Dearo; Ferreira, Mauricio Goncalves; Loffredo, Leonor Castro Monteiro; Scaf, Gulnara; Sakakura, Celso Eduardo

    2012-01-01

    This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC 95% :6.04-6.54) and 6.79 mm (IC 95% :6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64 mm(IC 95% :6.40-6.89) and 6.79 mm(IC 95% :6.45-7.11), respectively. The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

  3. Characterization of corn starch-based edible film incorporated with nutmeg oil nanoemulsion

    Science.gov (United States)

    Aisyah, Y.; Irwanda, L. P.; Haryani, S.; Safriani, N.

    2018-05-01

    This study aimed to formulate corn starch-based edible films by varying concentrations of nutmeg oil nanoemulsion and glycerol. Furthermore, the resulted edible film was characterized by its mechanical properties and antibacterial activity. The edible films were made using corn starch, nutmeg oil nanoemulsion, and glycerol. Concentrations of nutmeg oil nanoemulsion were 1%, 2%, and 3%, and glycerol were 10%, 20%, and 30%. Results indicated that the increase of nutmeg oil nanoemulsion concentration could increase the film thickness. However, the nutmeg oil had no effect on the film tensile strength and elongation. Glycerol had no effect on the film tensile strength. The best treatment of the corn starch-based film was obtained by adding 1% of nutmeg oil and 30% of glycerol, yielding a tensile strength of 18.73 Kgf/mm2, elongation of 69.44% and thickness of 0.0840. The addition of 1% nutmeg oil nanoemulsion has been able to inhibit the growth of two types of the bacteria tested (Staphylococcus aureus and Escherichia coli).

  4. Thin RuO2 conducting films grown by MOCVD for microelectronic applications

    International Nuclear Information System (INIS)

    Froehlich, K.; Cambel, V.; Machajdik, D.; Pignard, S.; Baumann, P. K.; Lindner, J.; Schumacher, M.

    2002-01-01

    We have prepared thin RuO 2 films by MOCVD using thermal evaporation of Ru(thd) 2 (cod) solid precursor. The films were prepared at deposition temperatures between 250 and 500 grad C on silicon and sapphire substrates. Different structure was observed for the RuO 2 films on these substrates; the films on Si substrate were polycrystalline, while X-ray diffraction analysis revealed epitaxial growth of RuO 2 on sapphire substrates. Polycrystalline RuO 2 films prepared at temperatures below 300 grad C on Si substrate exhibit smooth surface and excellent step coverage. Highly conformal growth of the RuO 2 films at low temperature and low pressure results in nearly 100% step coverage for sub-mm features with 1:1 aspect ratio. Resistivity of the polycrystalline RuO 2 at room temperature ranged between 100 and 200 μ x Ω x cm. These films are suitable for CMOS and RAM applications. (Authors)

  5. Measurement of interfacial displacement of a liquid film in microchannels using laser focus displacement meter

    International Nuclear Information System (INIS)

    Hazuku, Tatsuya; Fukamachi, Norihiro; Takamasa, Tomoji; Hibiki, Takashi

    2004-01-01

    This paper presents a new method for measuring the interfacial displacement of a liquid film in microchannels using a laser focus displacement meter (LFD). The purpose of the study is to clarify the effectiveness of the new method for obtaining detailed information concerning interfacial displacement, especially in the case of a thin liquid film, in micro- and mini-channels. To prevent the tube wall signal from disturbing that of the gas-liquid interface, a fluorocarbon tube with water box was used; the refraction index of this device is same as that for water. With this method, accurate instantaneous measurements of interfacial displacement of the liquid film were achieved. The error caused by refraction of the laser beam passing through the acrylic water box and fluorocarbon tube was estimated analytically and experimentally. The formulated analytical equation can estimate the real interface displacement using measured displacement in a fluorocarbon tube of 25 μm to 2.0 mm I.D. A preliminary test using fluorocarbon tubes of 1 and 2 mm I.D. showed that the corrected interface displacement calculated by the equation agreed with real displacement within a 1% margin of error. It was also confirmed that the LFD in the system could measure a liquid film of 0.25 μm at the thinnest. We made simultaneous measurements of the interface in fluorocarbon tubes of 0.5 and 1 mm I.D. using the LFD and a high-speed video camera with a microscope. These showed that the LFD could measure the interface of a liquid film with high spatial and temporal resolution during annular, slug, and piston flow regimes. The data also clarified the existence of a thin liquid film less than 1 μm in thickness in slug and annular flow regions. (author)

  6. Modification of Hack Saw Blade Support 'REMOR 400' from the Length of 650 mm to 450 mm

    International Nuclear Information System (INIS)

    Sagino, Abdul-Hafid

    2005-01-01

    REMOR 400 type is the hack saw machine for cutting large work piece. The capacity of cutting is 310 mm diameter. The length of the blade is 650 mm (26 inches). For cutting small work piece (≤ 150 mm), the use of this blade is not efficient because the blade is relatively expensive. To solve this problem, the modification of the blade support is performed so that REMOR 400 machine can use the blade of 450 mm which is cheaper and easier to find in the market. (author)

  7. Measurement on liquid film in microchannels using laser focus displacements meter

    International Nuclear Information System (INIS)

    Fukamachi, Norihiro; Tamura, Naohisa; Hazuku, Tatsuya; Takamasa, Tomoji

    2003-01-01

    To elucidate details of the fascinating nonlinear phenomena of gas-liquid interface in micro- and mini-channels, high spatial temporal knowledge of the interface in gas-liquid two-phase flows is essential. This paper presents a new method for measuring interface of liquid film in microchannels using a laser focus displacement meter(LFD). The purpose of the study was to clarify the effectiveness the new method for obtaining detailed information of interface displacement, especially in the case of thin liquid film, in micro- and mini-channels. In the test, water and nitrogen gas were used as working fluids. To eliminate the signal of tube wall disturbing that of gas-liquid interface, a fluorocarbon tube with water box was used; whose refraction index was the same as one of water. With this method, accurate measurements of the interface of liquid film, in real time, with sensitivity of 0.1 μm and 1 kHz, were achieved. The error caused by the refraction of the laser beam passing through the acrylic water box and fluorocarbon tube was estimated theoretically and experimentally. The formulated theoretical equation can derive the real interface displacement using measured displacement in a fluorocarbon tube of 25 μm -2.0 mm I.D. A preliminary test using fluorocarbon tubes of 1 and 2 mm in I.D. showed that the corrected interface displacement calculated by the equation agreed with real displacement within a 1% margin of error. Simultaneous measurement on the interface in a fluorocarbon tube of 0.5 and 1 mm in I.D. using the LFD and a high-speed camera movie with a microscope was carried out. It showed that the LFD could measure the interface of liquid film in high spatially and temporally in annular, slug and piston flow regions and clarified the existence of thin liquid film thinner than 1 μm in thickness in slug and annular regions. (author)

  8. The evaluation of Young's modulus and residual stress of Cu films by NiFe/Cu bilayer film microbridge tests

    International Nuclear Information System (INIS)

    Zhou Zhimin; Zhou Yong; Cao Ying; Ding Wen; Mao Haiping

    2008-01-01

    This paper proposes a method to estimate the thickness limit for single-layer microbridge tests and also the thickness limit of one film on another film with known thickness for bilayer microbridge tests. To evaluate the mechanical properties of the Cu film, which could not be measured by single-layer microbridge tests, the NiFe single-layer film and NiFe/Cu bilayer film on silicon substrate are fabricated onto the microbridge by the MEMS technique. A load–deflection experiment is conducted upon the ceramic shaft adhered to the microbridge center by means of the XP nanoindenter system. From single-layer microbridge theory, Young's modulus and the residual stress of the NiFe film are deduced to be 192.74 ± 8.10 GPa and 287.75 ± 16.18 MPa, respectively. The data are introduced into bilayer microbridge theory and Young's modulus and the residual stress of the copper film are calculated to be 118.71 ± 6.54 GPa and 41.34 ± 4.42 MPa, respectively. The experimental results correspond well with those of nanoindentation

  9. Verification and optimization of HDR surface mould brachytherapy plans using GAFCHROMIC EBT2 film: the ideal geometric case

    International Nuclear Information System (INIS)

    Sobolewski, Matthew; Haque, Mamoon

    2011-01-01

    Full text: Surface mould brachytherapy is used to treat superficial cancers due to conformal dose distributions and rapid dose fall-off with depth. In this work, we determine the effect of varying catheter number and prescription distance on dose distributions for surface mould plans using radiochromic film. Eight surface mould plans were generated using PLATO BPS (Version 14.3.2). Measurements were taken with Gafchromic EBT2 film over depths of 5-30 mm with an Ir-192 HDR source. Films were scanned using an Epson Expression 10000 XL flatbed scanner and analysed using RIT 113 software. The EBT2 films showed good agreement with an average difference of 2.8% compared to the planning system. The dose gradient in the interval ranging ±5 mm from the prescription point showed an 80% increase from the plan with maximum catheters (II) to the minimum (3). The size and extent of local dose maxima increased when fewer catheters were used. Increasing prescription distance decreased the dose gradient with a 20% reduction in dose occurring 4 mm superficially to the prescription point when prescription distance increased from 5 to 20 mm. Gafchromic EBT2 was used successfully to evaluate surface mould brachytherapy plans and is a useful tool for dose verification checks. High dose regions ne,u' to the catheter plane can be reduced by using a larger number of catheters and the prescription distance should be adjusted as a function of treatment depth varied by mould thickness.

  10. Development and characterization of bilayer films of FucoPol and chitosan.

    Science.gov (United States)

    Ferreira, Ana R V; Torres, Cristiana A V; Freitas, Filomena; Sevrin, Chantal; Grandfils, Christian; Reis, Maria A M; Alves, Vítor D; Coelhoso, Isabel M

    2016-08-20

    Bilayer films of FucoPol and chitosan were prepared and characterized in terms of optical, morphologic, hygroscopic, mechanical and barrier properties, to evaluate their potential application in food packaging. Bilayer films have shown dense and homogeneous layers, and presented enhanced properties when comparing to monolayer FucoPol films. Though, a high swelling degree in contact with liquid water (263.3%) and a high water vapour permeability (0.75×10(-11)mol/msPa), typical of polysaccharide films, was still observed. However, they presented a low permeability to O2 and CO2 (0.47×10(-16)molm/m(2)sPa and 5.8×10(-16)molm/m(2)sPa, respectively). Tensile tests revealed a flexible and resistant film with an elongation at break of 38% and an elastic modulus of 137MPa. The studied properties, in particular the excellent barrier to gases, impart these bilayer films potential to be used in packaging of low moisture content products, as well as in multilayered hydrophobic/hydrophilic/hydrophobic barriers for food products with a broader range of water content. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Application results of a prototype ultrasonic liquid film sensor to a 7 MPa steam-water two-phase flow experiment

    International Nuclear Information System (INIS)

    Aoyama, Goro; Fujimoto, Kiyoshi; Katono, Kenichi; Nagayoshi, Takuji; Baba, Atsushi; Yasuda, Kenichi

    2016-01-01

    A prototype ultrasonic liquid film sensor was applied to a high-temperature steam-water two-phase flow experiment. The liquid film sensor was vertically installed in a loop which was connected to HUSTLE, a multi-purpose steam source test facility. The hydraulic diameter of the measurement section was 9.4 mm. The output waveforms of the sensor were acquired with a digital oscilloscope. The fluid temperature and system pressure were kept at 288°C and 7.2 MPa, respectively, during the experiment. The pulse-echo method was used to calculate the liquid film thickness. The cross-correlation calculation was utilized to determine the time difference between the pulse reflected at the sensor surface and the pulse reflected at the liquid film surface. The time-averaged liquid film thicknesses were less than 0.055 mm in the annular flow condition. The increase of the time-averaged thickness was small with the change of the gas momentum flux. The film thicknesses measured with the sensor were compared with the past experimental results; the former were smaller than one-fourth of the thickness estimated as the mean film thickness. The comparison results suggested that the continuous liquid sublayer thickness was measured with the liquid film sensor. (author)

  12. "Tess of the D'Urbervilles": What the Film Left out.

    Science.gov (United States)

    Veidemanis, Gladys V.

    1988-01-01

    Compares Roman Polanski's film adaptation of "Tess of the D'Urbervilles" with the original novel by Thomas Hardy. Suggests that a comparative analysis of the two works enhances students' awareness of Hardy's artistry and sharpens their ability to respond critically to literature. (MM)

  13. UV laser deposition of metal films by photogenerated free radicals

    Science.gov (United States)

    Montgomery, R. K.; Mantei, T. D.

    1986-01-01

    A novel photochemical method for liquid-phase deposition of metal films is described. In the liquid phase deposition scheme, a metal containing compound and a metal-metal bonded carbonyl complex are dissolved together in a polar solvent and the mixture is irradiated using a UV laser. The optical arrangement consists of a HeCd laser which provides 7 mW of power at a wavelength of 325 nm in the TEM(OO) mode. The beam is attenuated and may be expanded to a diameter of 5-20 mm. Experiments with photochemical deposition of silver films onto glass and quartz substrates are described in detail. Mass spectrometric analysis of deposited silver films indicated a deposition rate of about 1 A/s at incident power levels of 0.01 W/sq cm. UV laser-induced copper and palladium films have also been obtained. A black and white photograph showing the silver Van Der Pauw pattern of a solution-deposited film is provided.

  14. Study of the electrodeposition of rhenium thin films by electrochemical quartz microbalance and X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Schrebler, R.; Cury, P.; Suarez, C.; Munoz, E.; Vera, F.; Cordova, R.; Gomez, H.; Ramos-Barrado, J.R.; Leinen, D.; Dalchiele, E.A.

    2005-01-01

    Rhenium thin films were prepared by electrodeposition from an aqueous solution containing 0.1 M Na 2 SO 4 +H 2 SO 4 , pH 2 in presence of y mM HReO 4 . As substrates polycrystalline gold (y=0.75 mM HReO 4 ) and monocrystalline n-Si(100) (y=40 mM HReO 4 ) were used. The electrochemical growth of rhenium was studied by cyclic voltammetry and electrochemical quartz microbalance on gold electrodes. The results found in the potential region before the hydrogen evolution reaction (her) showed that ReO 3 , ReO 2 and Re 2 O 3 with different hydration grades can be formed. In the potential region where the her is occurring, either on gold or n-Si(100) the electrodeposition of metallic rhenium takes place. On both substrates, rhenium films were formed by electrolysis at constant potential and X-ray photoelectron spectroscopy technique was used to characterise these deposits. It was concluded that the electrodeposited films were of metallic rhenium and only the uppermost atomic layer contained rhenium oxide species

  15. A broadband beam-steered fiber mm-wave link with high energy-spectral-spatial efficiency for 5G coverage

    NARCIS (Netherlands)

    Cao, Z.; Zhao, X.; Jiao, Y.; Deng, X.; Tessema, N.; Raz, O.; Koonen, A.M.J.

    2017-01-01

    Utilizing an integrated optical-tunable-delay-line, reversely-modulated single sideband modulation, and Nyquist subcarrier modulation, we demonstrate an 8 Gbps mm-wave beam steered link with a spatial-spectral efficiency of 16 bits/s/Hz.

  16. Structural-optical study of high-dielectric-constant oxide films

    Energy Technology Data Exchange (ETDEWEB)

    Losurdo, M. [Institute of Inorganic Methodologies and Plasmas, IMIP-CNR, Department of Chemistry and INSTM Universita di bari, Via Orabona 4, 70126 Bari (Italy)]. E-mail: maria.losurdo@ba.imip.cnr.it; Giangregorio, M.M. [Institute of Inorganic Methodologies and Plasmas, IMIP-CNR, Department of Chemistry and INSTM Universita di bari, Via Orabona 4, 70126 Bari (Italy); Luchena, M. [Institute of Inorganic Methodologies and Plasmas, IMIP-CNR, Department of Chemistry and INSTM Universita di bari, Via Orabona 4, 70126 Bari (Italy); Capezzuto, P. [Institute of Inorganic Methodologies and Plasmas, IMIP-CNR, Department of Chemistry and INSTM Universita di bari, Via Orabona 4, 70126 Bari (Italy); Bruno, G. [Institute of Inorganic Methodologies and Plasmas, IMIP-CNR, Department of Chemistry and INSTM Universita di bari, Via Orabona 4, 70126 Bari (Italy); Toro, R.G. [Dipartimento di Scienze Chimiche, Universita di Catania, and INSTM-UdR Catania, Viale A. Doria 6, I-95125 Catania (Italy); Malandrino, G. [Dipartimento di Scienze Chimiche, Universita di Catania, and INSTM-UdR Catania, Viale A. Doria 6, I-95125 Catania (Italy); Fragala, I.L. [Dipartimento di Scienze Chimiche, Universita di Catania, and INSTM-UdR Catania, Viale A. Doria 6, I-95125 Catania (Italy); Nigro, R. Lo [Istituto di Microelettronica e Microsistemi, IMM-CNR, Stradale Primosole 50, I-95121 Catania (Italy)

    2006-10-31

    High-k polycrystalline Pr{sub 2}O{sub 3} and amorphous LaAlO{sub 3} oxide thin films deposited on Si(0 0 1) are studied. The microstructure is investigated using X-ray diffraction and scanning electron microscopy. Optical properties are determined in the 0.75-6.5 eV photon energy range using spectroscopic ellipsometry. The polycrystalline Pr{sub 2}O{sub 3} films have an optical gap of 3.86 eV and a dielectric constant of 16-26, which increases with film thickness. Similarly, very thin amorphous LaAlO{sub 3} films have the optical gap of 5.8 eV, and a dielectric constant below 14 which also increases with film thickness. The lower dielectric constant compared to crystalline material is an intrinsic characteristic of amorphous films.

  17. Eddy Current Testing for Detecting Small Defects in Thin Films

    Science.gov (United States)

    Obeid, Simon; Tranjan, Farid M.; Dogaru, Teodor

    2007-03-01

    Presented here is a technique of using Eddy Current based Giant Magneto-Resistance sensor (GMR) to detect surface and sub-layered minute defects in thin films. For surface crack detection, a measurement was performed on a copper metallization of 5-10 microns thick. It was done by scanning the GMR sensor on the surface of the wafer that had two scratches of 0.2 mm, and 2.5 mm in length respectively. In another experiment, metal coatings were deposited over the layers containing five defects with known lengths such that the defects were invisible from the surface. The limit of detection (resolution), in terms of defect size, of the GMR high-resolution Eddy Current probe was studied using this sample. Applications of Eddy Current testing include detecting defects in thin film metallic layers, and quality control of metallization layers on silicon wafers for integrated circuits manufacturing.

  18. Experimental measurements of spatial dose distributions in radiosurgery treatments

    International Nuclear Information System (INIS)

    Avila-Rodriguez, M. A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Perez-Pastenes, M. A.

    2001-01-01

    The measurement of stereotactic radiosurgery dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. This paper describes the use of a commercial radiochromic dye film (GafChromic MD-55-2) to measure radiosurgery dose distributions with 6 MV X-rays in a head phantom. The response of the MD-55-2 was evaluated by digitizing and analyzing the films with conventional computer systems. Radiosurgery dose distributions were measured using the radiochromic film in a spherical acrylic phantom of 16 cm diameter undergoing a typical SRS treatment as a patient, and were compared with dose distributions provided by the treatment planning system. The comparison lead to mean radial differences of ±0.6 mm, ±0.9 mm, ±1.3 mm, ±1.9 mm, and ±2.8 mm, for the 80, 60, 50, 40, and 30% isodose curves, respectively. It is concluded that the radiochromic film is a convenient and useful tool for radiosurgery treatment planning validation

  19. Application of CBD-Zinc Sulfide Film as an Antireflection Coating on Very Large Area Multicrystalline Silicon Solar Cell

    Directory of Open Access Journals (Sweden)

    U. Gangopadhyay

    2007-01-01

    Full Text Available The low-cost chemical bath deposition (CBD technique is used to prepare CBD-ZnS films as antireflective (AR coating for multicrystalline silicon solar cells. The uniformity of CBD-ZnS film on large area of textured multicrystalline silicon surface is the major challenge of CBD technique. In the present work, attempts have been made for the first time to improve the rate of deposition and uniformity of deposited film by controlling film stoichiometry and refractive index and also to minimize reflection loss by proper optimization of molar percentage of different chemical constituents and deposition conditions. Reasonable values of film deposition rate (12.13 Å′/min., good film uniformity (standard deviation <1, and refractive index (2.35 along with a low percentage of average reflection (6-7% on a textured mc-Si surface are achieved with proper optimization of ZnS bath. 12.24% efficiency on large area (125 mm × 125 mm multicrystalline silicon solar cells with CBD-ZnS antireflection coating has been successfully fabricated. The viability of low-cost CBD-ZnS antireflection coating on large area multicrystalline silicon solar cell in the industrial production level is emphasized.

  20. Paraconductivity and excess Hall effect of YBa2Cu3Ox thin films

    International Nuclear Information System (INIS)

    Gueffaf, A.

    2001-10-01

    Superconducting YBa 2 Cu 3 O x thin films were produced by in situ off-axis RF magnetron sputter deposition using a stoichiometric single target (T1). The effects of individual deposition parameters on the film properties are discussed. The transition temperatures for films deposited on MgO (100) are slightly lower than that for the SrTiO 3 and LaAlO 3 (100)-oriented substrates. The lower transition temperatures in the MgO substrates are most likely the result of the larger lattice mismatch with YBa 2 Cu 3 O x . All films grown on (100) substrates are c-axis oriented. The orientation of the sputtered YBCO films appears to depend only on the substrate orientation and not on the substrate material choice. Typical results for the c-axis lattice parameter c for various YBCO thin films sputtered onto SrTiO 3 , LaAIO 3 and MgO all (100)-oriented substrates with a range of T c values are presented. Three different targets were used in the course of this work: the first one (T1) was a 60 mm diameter, 3 mm thickness high density commercial YBCO disc; the second one (T2) was a 35 mm diameter, 4 mm thickness high density YBCO disc; and the third one (T3) was a 60 mm diameter, 3 mm thickness YBCO powder pressed then sintered on a copper plate substrate. The latter two were manufactured in house and are reported here for the first time. The best results were obtained using T1. The best films had T c (onset)= 89-93 K close to that of bulk YBCO and a transition width ΔT c =2-5 K. But some other films exhibited lower critical temperatures T c (onset)= 62-70 K and broader transitions ΔT c = 10.4-13.6 K. These reductions in T c and the broadening of the transition are due to oxygen deficiency. This is shown by the c-axis lattice parameter calculations. All films grown using T2 and T3 exhibited lower critical temperatures and broader transitions for the same reason. A novel heater element was manufactured and a previous heater design was modified for adaptation of the new element

  1. Radiographic film dosimetry of proton beams for depth‐dose constancy check and beam profile measurement

    Science.gov (United States)

    Teran, Anthony; Ghebremedhin, Abiel; Johnson, Matt; Patyal, Baldev

    2015-01-01

    Radiographic film dosimetry suffers from its energy dependence in proton dosimetry. This study sought to develop a method of measuring proton beams by the film and to evaluate film response to proton beams for the constancy check of depth dose (DD). It also evaluated the film for profile measurements. To achieve this goal, from DDs measured by film and ion chamber (IC), calibration factors (ratios of dose measured by IC to film responses) as a function of depth in a phantom were obtained. These factors imply variable slopes (with proton energy and depth) of linear characteristic curves that relate film response to dose. We derived a calibration method that enables utilization of the factors for acquisition of dose from film density measured at later dates by adapting to a potentially altered processor condition. To test this model, the characteristic curve was obtained by using EDR2 film and in‐phantom film dosimetry in parallel with a 149.65 MeV proton beam, using the method. An additional validation of the model was performed by concurrent film and IC measurement perpendicular to the beam at various depths. Beam profile measurements by the film were also evaluated at the center of beam modulation. In order to interpret and ascertain the film dosimetry, Monte Carlos simulation of the beam was performed, calculating the proton fluence spectrum along depths and off‐axis distances. By multiplying respective stopping powers to the spectrum, doses to film and water were calculated. The ratio of film dose to water dose was evaluated. Results are as follows. The characteristic curve proved the assumed linearity. The measured DD approached that of IC, but near the end of the spread‐out Bragg peak (SOBP), a spurious peak was observed due to the mismatch of distal edge between the calibration and measurement films. The width of SOBP and the proximal edge were both reproducible within a maximum of 5 mm; the distal edge was reproducible within 1 mm. At 5 cm depth, the

  2. High intensification screen-film systems in thorax radiography: a clinical comparison

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Sokiranski, R.; Claussen, C.D.

    1995-01-01

    Objective: The quality of chest images was evaluated for a conventional screen-film system, a new asymmetric screen-film system, and a new uv screen-film system. Materials and Methods: 138 Chest radiographs (69 p.a., 69 lateral) obtained with three different high intensification screen-film combinations were compared. Film density and film contrast were measured. Three readers graded the image quality according to 16 criteria. Results: The asymmetric film-screen combination Insight HC showed the lowest film contrast, the best exposure range, and a elevated film density in the mediastinal area. The asymmetric screen-film system was ranked by all three observers as being substantially better in image quality. Conclusion: Compared to conventional screen-film systems, the new screen-film systems can improve the image quality of chest radiographs. Therefore, the new high intensification screen-film combinations can be used as a low cost alternative to the Amber technique and digital radiography. (orig.) [de

  3. A new method of readout in radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Kellermann, Peer Oliver; Gornik, Erich; Ertl, Adolf

    1998-01-01

    Radiochromic film as a dosimetry medium offers several advantages in high-resolution radiography. A new technique of readout was developed to measure the optical density distributions of the film in purely directed light. This technique implements radiochromic film dosimetry near the film's absorption maximum by using a single-mode top-surface emitting laser diode (675.2 nm). The effective sensitivity of the film, compared with a helium-neon laser densitometer (632.8 nm), is increased approximately threefold. Good accuracy, high spatial resolution and simple assembly of the readout system is achieved. Beam profiles of the four final collimator helmets of a Leksell Gamma Knife (Elekta Inc., Sweden) were experimentally determined. Measured profiles and full-widths at half maximum are consistent with the computer generated data of the dose planning system (Kula 4.4, Elekta Inc., Sweden). The output factor of the 4 mm collimator (the smallest collimator with the steepest dose gradient), essential for the application of well defined doses, was checked. The measurements established an output factor of 826±9 that lies 9±1% lower than the adjusted one. (author)

  4. Dynamic measurement of liquid film thickness in stratified flow by using ultrasonic echo technique

    International Nuclear Information System (INIS)

    Serizawa, A.; Nagane, K.; Kamei, T.; Kawara, Z.; Ebisu, T.; Torikoshi, K.

    2004-01-01

    We developed a technique to measure time-dependent local film thickness in stratified air-water flow over a horizontal plate by using a time of flight of ultrasonic transmission. The ultrasonic echoes reflected at the liquid/air interfaces are detected by a conventional ultrasonic instrumentation, and the signals are analyzed by a personal computer after being digitalized by an A/D converter to give the time of flight for the ultrasonic waves to run over a distance of twice of the film thickness. A 3.8 mm diameter probe type ultrasonic transducer was used in the present work which transmits and receives 10 MHz frequency ultrasonic waves. The estimated spatial resolution with this arrangement is 0.075 mm in film thickness for water. The time resolution, which depends on both the A/D converter and the memory capacity was up to several tens Hz. We also discussed the sensitivity of the method to the inclination angle of the interfaces. (author)

  5. Low temperature aluminum nitride thin films for sensory applications

    Energy Technology Data Exchange (ETDEWEB)

    Yarar, E.; Zamponi, C.; Piorra, A.; Quandt, E., E-mail: eq@tf.uni-kiel.de [Institute for Materials Science, Chair for Inorganic Functional Materials, Kiel University, D-24143 Kiel (Germany); Hrkac, V.; Kienle, L. [Institute for Materials Science, Chair for Synthesis and Real Structure, Kiel University, D-24143 Kiel (Germany)

    2016-07-15

    A low-temperature sputter deposition process for the synthesis of aluminum nitride (AlN) thin films that is attractive for applications with a limited temperature budget is presented. Influence of the reactive gas concentration, plasma treatment of the nucleation surface and film thickness on the microstructural, piezoelectric and dielectric properties of AlN is investigated. An improved crystal quality with respect to the increased film thickness was observed; where full width at half maximum (FWHM) of the AlN films decreased from 2.88 ± 0.16° down to 1.25 ± 0.07° and the effective longitudinal piezoelectric coefficient (d{sub 33,f}) increased from 2.30 ± 0.32 pm/V up to 5.57 ± 0.34 pm/V for film thicknesses in the range of 30 nm to 2 μm. Dielectric loss angle (tan δ) decreased from 0.626% ± 0.005% to 0.025% ± 0.011% for the same thickness range. The average relative permittivity (ε{sub r}) was calculated as 10.4 ± 0.05. An almost constant transversal piezoelectric coefficient (|e{sub 31,f}|) of 1.39 ± 0.01 C/m{sup 2} was measured for samples in the range of 0.5 μm to 2 μm. Transmission electron microscopy (TEM) investigations performed on thin (100 nm) and thick (1.6 μm) films revealed an (002) oriented AlN nucleation and growth starting directly from the AlN-Pt interface independent of the film thickness and exhibit comparable quality with the state-of-the-art AlN thin films sputtered at much higher substrate temperatures.

  6. Receptor saturation in roentgen films

    Energy Technology Data Exchange (ETDEWEB)

    Strid, K G; Reichmann, S [Sahlgrenska Sjukhuset, Goeteborg (Sweden)

    1980-01-01

    Roentgen-film recording of small object details of low attenuation differences (e.g. pulmonary vessels) is regularly seen to be impaired when the film is exposed to yield high values of optical density (D). This high-density failure is due to receptor saturation, which implies that at high exposure values most silver halide grains of the film are made developable, leaving few grains available to receive additional informative photons. The receptor saturation is analysed by means of a mathematical model of a non-screen film yielding Dsub(max) = 2.0. Optimum recording, defined by maximum signal-to-noise ratio in the image, is found at D approximately 0.64, corresponding to, on an average, 1.6 photons absorbed per grain. On the other hand, maximum contrast occurs at D approximately 1.4, where, on the average, 3.6 photons are absorbed per grain. The detective quantum efficiency of the film, i.e. the fraction of the photons actually contributing to the information content of the image, drops from 41 per cent at maximum signal-to-noise ratio to a mere 10 per cent at maximum contrast.

  7. Attractiveness of MM-X Traps Baited with Human or Synthetic Odor to Mosquitoes (Diptera: Culicidae) in The Gambia

    Science.gov (United States)

    QIU, YU TONG; SMALLEGANGE, RENATE C.; TER BRAAK, CAJO J. F.; SPITZEN, JEROEN; VAN LOON, JOOP J. A.; JAWARA, MUSA; MILLIGAN, PAUL; GALIMARD, AGNES M.; VAN BEEK, TERIS A.; KNOLS, BART G. J.; TAKKEN, WILLEM

    2013-01-01

    Chemical cues play an important role in the host-seeking behavior of blood-feeding mosquitoes (Diptera: Culicidae). A field study was carried out in The Gambia to investigate the effects of human odor or synthetic odor blends on the attraction of mosquitoes. MM-X traps baited with 16 odor blends to which carbon dioxide (CO2) was added were tested in four sets of experiments. In a second series of experiments, MM-X traps with 14 odor blends without CO2 were tested. A blend of ammonia and l-lactic acid with or without CO2 was used as control odor in series 1 and 2, respectively. Centers for Disease Control and Prevention (CDC) traps were placed in a traditional house and an experimental house to monitor mosquito densities during the experiments. The MM-X traps caught a total number of 196,756 mosquitoes, with the most abundant species belonging to the genera Mansonia (70.6%), Anopheles (17.5%), and Culex (11.5%). The most abundant mosquito species caught by the CDC traps (56,290 in total) belonged to the genera Mansonia (59.4%), Anopheles (16.0% An. gambiae s.l. Giles, and 11.3% An. ziemanni Grünberg), and Culex (11.6%). MM-X traps baited with synthetic blends were in many cases more attractive than MM-X traps baited with human odors. Addition of CO2 to synthetic odors substantially increased the catch of all mosquito species in the MM-X traps. A blend of ammonia + L-lactic acid + CO2 + 3-methylbutanoic acid was the most attractive odor for most mosquito species. The candidate odor blend shows the potential to enhance trap collections so that traps will provide better surveillance and possible control. PMID:18047195

  8. ITO thin films deposited by advanced pulsed laser deposition

    International Nuclear Information System (INIS)

    Viespe, Cristian; Nicolae, Ionut; Sima, Cornelia; Grigoriu, Constantin; Medianu, Rares

    2007-01-01

    Indium tin oxide thin films were deposited by computer assisted advanced PLD method in order to obtain transparent, conductive and homogeneous films on a large area. The films were deposited on glass substrates. We studied the influence of the temperature (room temperature (RT)-180 deg. C), pressure (1-6 x 10 -2 Torr), laser fluence (1-4 J/cm 2 ) and wavelength (266-355 nm) on the film properties. The deposition rate, roughness, film structure, optical transmission, electrical conductivity measurements were done. We deposited uniform ITO thin films (thickness 100-600 nm, roughness 5-10 nm) between RT and 180 deg. C on a large area (5 x 5 cm 2 ). The films have electrical resistivity of 8 x 10 -4 Ω cm at RT, 5 x 10 -4 Ω cm at 180 deg. C and an optical transmission in the visible range, around 89%

  9. Usefulness of CT-guided automatic needle biopsy of solitary pulmonary nodule smaller than 15 mm

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lim, Yeong Su

    2004-01-01

    To evaluate the usefulness of the CT-guided percutaneous lung biopsy for the solitary pulmonary nodules smaller than 15 mm in diameter. Between April 2002 and May 2003, we evaluated twenty-five patients (11 men, 14 women, mean ages: 52.5 years) who had solitary pulmonary nodules, which we could not discriminate as being benign or malignant on the CT findings. All the subjects had CT-guided percutaenous cutting needle biopsy (PCNB) performed on them at our institution. A definitive diagnosis of benignity or malignancy was established to retrospectively analyze the patient's records. We evaluated the accuracy, sensitivity, specificity and complications of PCNB for the definitive diagnosis of benignity or malignancy. The sensitivity and specificity of PCNB were determined using the Chi-square test, and the correlations with pneumothorax and emphysema after biopsy were analyzed using Spearman's rank correlation coefficient. In two nodules of the twenty-five nodules, no definitive diagnosis could be established. Of the remaining twenty-three nodules, 7 (30.4%) were malignant and 16 (69.6%) were benign. Twenty (87%) of the twenty-three definitively diagnosed nodules were correctly diagnosed with PCNB. Of the twenty nodules, 6 (30%) were malignant and 14 (70%) were benign. The sensitivity and specificity of the malignant nodules were 85.7% (6/7) and 100% (16/16), respectively. The sensitivity and specificity of the benign nodules were 87.5% (14/16) and 85.7% (6/7), respectively. Post-biopsy complication occurred in nine patients (36%): Hemoptysis (n=4, 16%) and pneumothorax (n=5, 20%). However, there was not a statistical significance between pneumothorax and emphysema after biopsy (r=0.3, p=0.15). When CT-guided percutaneous lung biopsy of the solitary pulmonary nodules smaller than 15 mm in diameter was performed without an on-site cytopathologist, we know that PCNB can yield high diagnostic accuracy and very few complications

  10. Fabrication of Flexible Arrayed Lactate Biosensor Based on Immobilizing LDH-NAD+ on NiO Film Modified by GO and MBs

    Science.gov (United States)

    Yan, Siao-Jie; Liao, Yi-Hung; Lai, Chih-Hsien; Wu, You-Xiang; Wu, Cian-Yi; Chen, Hsiang-Yi; Huang, Hong-Yu; Wu, Tong-Yu

    2017-01-01

    We proposed the flexible arrayed lactate biosensor based on immobilizing l-lactate dehydrogenase (LDH) and nicotinamide adenine dinucleotide (NAD+) on nickel oxide (NiO) film, and which the average sensitivity could be enhanced by using graphene oxide (GO) and magnetic beads (MBs). By using GO and MBs, it exhibits excellent sensitivity (45.397 mV/mM) with a linearity of 0.992 in a range of 0.2 mM to 3 mM. According to the results of electrochemical impedance spectroscopy (EIS), the electron transfer resistance of LDH-NAD+-MBs/GPTS/GO/NiO film was smaller than those of LDH-NAD+/GPTS/GO/NiO film and LDH-NAD+/GPTS/NiO film, and it presented the outstanding electron transfer ability. After that, the limit of detection, anti-interference effect and bending test were also investigated. PMID:28704960

  11. Fabrication of Flexible Arrayed Lactate Biosensor Based on Immobilizing LDH-NAD+ on NiO Film Modified by GO and MBs

    Directory of Open Access Journals (Sweden)

    Jung-Chuan Chou

    2017-07-01

    Full Text Available We proposed the flexible arrayed lactate biosensor based on immobilizing l-lactate dehydrogenase (LDH and nicotinamide adenine dinucleotide ( NAD + on nickel oxide (NiO film, and which the average sensitivity could be enhanced by using graphene oxide (GO and magnetic beads (MBs. By using GO and MBs, it exhibits excellent sensitivity (45.397 mV/mM with a linearity of 0.992 in a range of 0.2 mM to 3 mM. According to the results of electrochemical impedance spectroscopy (EIS, the electron transfer resistance of LDH- NAD + -MBs/GPTS/GO/NiO film was smaller than those of LDH-NAD+/GPTS/GO/NiO film and LDH- NAD + /GPTS/NiO film, and it presented the outstanding electron transfer ability. After that, the limit of detection, anti-interference effect and bending test were also investigated.

  12. Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

    International Nuclear Information System (INIS)

    Tipper, G.; U-King-Im, J.M.; Price, S.J.; Trivedi, R.A.; Cross, J.J.; Higgins, N.J.; Farmer, R.; Wat, J.; Kirollos, R.; Kirkpatrick, P.J.; Antoun, N.M.; Gillard, J.H.

    2005-01-01

    AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe

  13. Films of Agarose Enable Rapid Formation of Giant Liposomes in Solutions of Physiologic Ionic Strength

    OpenAIRE

    Horger, Kim S.; Estes, Daniel J.; Capone, Ricardo; Mayer, Michael

    2009-01-01

    This paper describes a method to form giant liposomes in solutions of physiologic ionic strength, such as phosphate buffered saline (PBS) or 150 mM KCl. Formation of these cell-sized liposomes proceeded from hybrid films of partially dried agarose and lipids. Hydrating the films of agarose and lipids in aqueous salt solutions resulted in swelling and partial dissolution of the hybrid films and in concomitant rapid formation of giant liposomes in high yield. This method did not require the pre...

  14. Surface films and corrosion of copper

    International Nuclear Information System (INIS)

    Hilden, J.; Laitinen, T.; Maekelae, K.; Saario, T.; Bojinov, M.

    1999-03-01

    In Sweden and Finland the spent nuclear fuel is planned to be encapsulated in cast iron canisters that have an outer shield made of copper. The copper shield is responsible for the corrosion protection of the canister construction. General corrosion of the copper is not expected to be the limiting factor in the waste repository environment when estimating the life-time of the canister construction. However, different forms of localised corrosion, i.e. pitting, stress corrosion cracking, or environmentally assisted creep fracture may cause premature failure of the copper shield. Of the probable constituents in the groundwater, nitrites, chlorides, sulphides and carbonates have been suggested to promote localised corrosion of copper. The main assumption made in planning this research program is that the surface films forming on copper in the repository environment largely determine the susceptibility of copper to the different forms of localised corrosion. The availability of reactants, which also may become corrosion rate limiting, is investigated in several other research programs. This research program consists of a set of successive projects targeted at characterising the properties of surface films on copper in repository environment containing different detrimental anions. A further aim was to assess the significance of the anion-induced changes in the stability of the oxide films with regard to localised corrosion of copper. This report summarises the results from a series of investigations on properties of surface films forming on copper in water of pH = 8.9 at temperature of 80 deg C and pressure of 2 MPa. The main results gained so far in this research program are as follows: The surface films forming on copper in the thermodynamic stability region of monovalent copper at 80 deg C consist of a bulk part (about 1 mm thick) which is a good ionic and electronic conductor, and an outer, interfacial layer (0.001 - 0.005 mm thick) which shows p-type semiconductor

  15. High Resolution Spectroscopy of 16N#Lambda# by Electroproduction

    International Nuclear Information System (INIS)

    Cusanno, Francesco; Urciuoli, Guido; Acha Quimper, Armando; Ambrozewicz, Pawel; Aniol, Konrad; Baturin, Pavlo; Bertin, Pierre; Benaoum, Hachemi; Blomqvist, Ingvar; Boeglin, Werner; Breuer, Herbert; Brindza, Paul; Bydzovsky, Petr; Camsonne, Alexandre; Chang, C.; Chang, C.C.; Chen, Jian-Ping; Choi, Seonho; Chudakov, Eugene; Cisbani, Evaristo; Colilli, Stefano; Coman, Luminita; Craver, Brandon; de Cataldo, Giacinto; De Jager, Cornelis; De Leo, Raffaele; Deur, Alexandre; Ferdi, Catherine; Feuerbach, Robert; Folts, Edward; Frullani, Salvatore; Garibaldi, Franco; Gayou, Olivier; Giuliani, Fausto; Gomez, Javier; Gricia, Massimo; Hansen, Jens-Ole; Hayes, David; Higinbotham, Douglas; Holmstrom, Timothy; Hyde, Charles; Ibrahim, Hassan; Iodice, Mauro; Jiang, Xiaodong; Kaufman, Lisa; Kino, Kouichi; Kross, Brian; Lagamba, Luigi; LeRose, John; Lindgren, Richard; Lucentini, Maurizio; Margaziotis, Demetrius; Markowitz, Pete; Marrone, Stefano; Meziani, Zein-Eddine; McCormick, Kathy; Michaels, Robert; Millener, D.; Miyoshi, Toshinobu; Moffit, Bryan; Monaghan, Peter; Moteabbed, Maryam; Munoz Camacho, Carlos; Nanda, Sirish; Nappi, E.; Nelyubin, Vladimir; Norum, Blaine; Okasyasu, Y.; Paschke, Kent; Perdrisat, Charles; Piasetzky, Eliazer; Punjabi, Vina; Qiang, Yi; Raue, Brian; Reimer, Paul; Reinhold, Joerg; Reitz, Bodo; Roche, Rikki; Rodriguez, Victor; Saha, Arunava; Santavenere, Fabio; Sarty, Adam; Segal, John; Shahinyan, Albert; Singh, Jaideep; Sirca, Simon; Snyder, Ryan; Solvignon, Patricia; Sotona, M.; Sotona, Miloslav; Subedi, Ramesh; Sulkosky, Vince; Sulkosky, Vincent; Suzuki, Tomokazu; Ueno, Hiroaki; Ulmer, Paul; Veneroni, P.P.; Voutier, Eric; Wojtsekhowski, Bogdan; Zeng, X.; Zorn, Carl

    2009-01-01

    An experimental study of the 16O(e, e'K+)16N # Lambda# reaction has been performed at Jefferson Lab. A thin film of falling water was used as a target. This permitted a simultaneous measurement of the p(e, e'K+)Λ,Σ 0 exclusive reactions and a precise calibration of the energy scale. A ground-state binding energy of 13.76 ± 0.16 MeV was obtained for 16N # Lambda# with better precision than previous measurements on the mirror hypernucleus 16O # Lambda#. Precise energies have been determined for peaks arising from a Lambda in s and p orbits coupled to the p1/2 and p3/2 hole states of the 15N core nucleus.

  16. Technical and clinical evaluation of an improved-contrast screen-film combination for radiation therapy portal localization imaging

    International Nuclear Information System (INIS)

    Haus, Arthur G.; Dickerson, Robert E.; Huff, Kenneth E.; Monte, Suzanne; Schlager, Barbara A.; Atanas, Meri; Matloubieh, Ahmad

    1996-01-01

    Purpose/Objective: A problem with conventional radiation therapy portal images is low image contrast, due in part to the low attenuation of the exposing radiation by the anatomical parts being imaged and the contrast capabilities of the film or screen-film combination. The purpose of this study was to design, develop and clinically evaluate a new screen-film combination for portal localization imaging which provides significantly higher contrast and therefore improved image quality. Materials and Methods: Comparison phantom and clinical images were made at two radiation oncology facilities with the new prototype screen-film combination and a commercial screen-film combination currently used for portal localization imaging. All images were made with linear accelerators at 6MV. Sensitometric data was also obtained. The prototype combination features a 1.0mm copper front screen plus front and back gadolinium oxysulfide fluorescent intensifying screens and a very-slow-speed film having inherently high contrast. The film emulsion layers are coated on a 7 mil Estar base which allows processing in a conventional rapid process film processor. For this combination, the film is exposed primarily by light from the intensifying screens. The current, commercially available screen-film combination was a Kodak X-Omatic L Radiation Therapy Cassette with a 1.0mm copper front screen and a 0.25mm lead back screen and Kodak X-Omat RP film in ready pack envelope. With this combination, the film emulsion is exposed by electrons generated in the metal screens. All films were processed in a Kodak M35A X-Omat processor. Radiation oncologists reviewed the phantom and clinical images. Results: Sensitometric data indicate that the film contrast (average gradient) of the new prototype combination is approximately 4 times higher than the conventional commercially available combination. Phantom and clinical comparisons at St. Mary Cancer Center, Langhorne PA. and the Daisy Marquis Jones

  17. Transverse piezoelectric coefficient measurement of flexible lead zirconate titanate thin films

    Energy Technology Data Exchange (ETDEWEB)

    Dufay, T.; Guiffard, B.; Seveno, R. [LUNAM Université, Université de Nantes, IETR (Institut d' Électronique et de Télécommunications de Rennes), UMR CNRS 6164, 2 rue de la Houssinière, BP 92208, 44322 Nantes Cedex 3 (France); Thomas, J.-C. [LUNAM Université, Université de Nantes-École Centrale Nantes, GeM (Institut de Recherche en Génie Civil et Ingénierie Mécanique), UMR CNRS 6183, 2 rue de la Houssinière, BP 92208, 44322 Nantes Cedex 3 (France)

    2015-05-28

    Highly flexible lead zirconate titanate, Pb(Zr,Ti)O{sub 3} (PZT), thin films have been realized by modified sol-gel process. The transverse piezoelectric coefficient d{sub 31} was determined from the tip displacement of bending-mode actuators made of PZT cantilever deposited onto bare or RuO{sub 2} coated aluminium substrate (16 μm thick). The influence of the thickness of ruthenium dioxide RuO{sub 2} and PZT layers was investigated for Pb(Zr{sub 0.57}Ti{sub 0.43})O{sub 3}. The modification of Zr/Ti ratio from 40/60 to 60/40 was done for 3 μm thick PZT thin films onto aluminium (Al) and Al/RuO{sub 2} substrates. A laser vibrometer was used to measure the beam displacement under controlled electric field. The experimental results were fitted in order to find the piezoelectric coefficient. Very large tip deflections of about 1 mm under low voltage (∼8 V) were measured for every cantilevers at the resonance frequency (∼180 Hz). For a given Zr/Ti ratio of 58/42, it was found that the addition of a 40 nm thick RuO{sub 2} interfacial layer between the aluminium substrate and the PZT layer induces a remarkable increase of the d{sub 31} coefficient by a factor of 2.7, thus corresponding to a maximal d{sub 31} value of 33 pC/N. These results make the recently developed PZT/Al thin films very attractive for both low frequency bending mode actuating applications and vibrating energy harvesting.

  18. 19 CFR 114.22 - Coverage of carnets.

    Science.gov (United States)

    2010-04-01

    ... Convention to Facilitate the Importation of Commercial Samples and Advertising Material, which includes: (i) Commercial samples, or (ii) Motion picture advertising films not exceeding 16 mm., consisting essentially of... carnet covering motion picture advertising films a statement showing how each of the following...

  19. Thermal neutron imaging through XRQA2 GAFCHROMIC films coupled with a cadmium radiator

    Energy Technology Data Exchange (ETDEWEB)

    Sacco, D. [INFN – LNF, Via E. Fermi n.40, Frascati, 00044 Roma (Italy); INAIL – DIT, Via di Fontana Candida n.1, 00040 Monteporzio Catone (Italy); Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN – LNF, Via E. Fermi n.40, Frascati, 00044 Roma (Italy); Bortot, D. [Politecnico di Milano, Dipartimento di Energia, Via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria16, 20133 Milano (Italy); Palomba, M. [ENEA Casaccia, Via Anguillarese, 301, S. Maria di Galeria, 00123 Roma (Italy); Pola, A. [Politecnico di Milano, Dipartimento di Energia, Via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria16, 20133 Milano (Italy); Introini, M.V.; Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, Via La Masa 34, 20156 Milano (Italy); Gentile, A. [INFN – LNF, Via E. Fermi n.40, Frascati, 00044 Roma (Italy); Strigari, L. [Laboratory of Medical Physics, Regina Elena National Cancer Institute, Via E. Chianesi 53, 00144 Roma (Italy); Pressello, C. [Department of Medical Physics, Azienda Ospedaliera San Camillo Forlanini, Circonvallazione Gianicolense 87, 00152 Roma (Italy); Soriani, A. [Laboratory of Medical Physics, Regina Elena National Cancer Institute, Via E. Chianesi 53, 00144 Roma (Italy); Gómez-Ros, J.M. [INFN – LNF, Via E. Fermi n.40, Frascati, 00044 Roma (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain)

    2015-10-21

    A simple and inexpensive method to perform passive thermal neutron imaging on large areas was developed on the basis of XRQA2 GAFCHROMIC films, commonly employed for quality assurance in radiology. To enhance their thermal neutron response, the sensitive face of film was coupled with a 1 mm thick cadmium radiator, forming a sandwich. By exchanging the order of Cd filter and sensitive film with respect to the incident neutron beam direction, two different configurations (beam-Cd-film and beam-film-Cd) were identified. These configurations were tested at thermal neutrons fluence values in the range 10{sup 9}–10{sup 10} cm{sup −2}, using the ex-core radial thermal neutron column of the ENEA Casaccia – TRIGA reactor. The results are presented in this work.

  20. Quantum-well-driven magnetism in thin films

    DEFF Research Database (Denmark)

    Mirbt, S.; Johansson, B.; Skriver, Hans Lomholt

    1996-01-01

    We have performed local spin-density calculations for an fee (100) Ag substrate covered by 1 to 16 monolayers (ML) of Pd. We find that thin films of Pd are magnetic with a moment of the order of 0.3 mu(B) except for films of 1-2 ML and 5-7 ML where magnetism is completely suppressed. We present...... a physically transparent explanation of this behavior in terms of the Stoner picture and magnetic quantum-well states....

  1. Observations on dual-ended readout of 100 mm long LYSO crystals

    International Nuclear Information System (INIS)

    Ur-Rehman, Fazal; McIntosh, Bryan; Goertzen, Andrew L.

    2011-01-01

    We are investigating using dual-ended readout of axially oriented long thin scintillator crystals in detectors for a compact geometry, small ring diameter animal PET system. The axial position of interaction is determined from the light sharing between two photodetectors at opposite ends of the crystal. We examine the light output, energy resolution and axial spatial resolution of 1.5-5x2x100 mm 3 polished LYSO crystals by irradiating with an electronically collimated beam of 511 keV photons oriented perpendicular to the long axis and read out at either end by position sensitive photomultiplier tubes (PSPMTs). Three reflector materials, namely Teflon, 3 M enhanced specular reflector (ESR) and black paint are examined for the 2x2x100 mm 3 crystal size. The light output increases and energy resolution improves with the crystal cross-section. Generally, the spatial resolution worsens with increase in crystal cross-section. For the 2x2x100 mm 3 crystal size, the mean energy resolutions of the photopeak over the nine irradiation positions were 14.4±0.4%, 16.0±1.2% and 28.3±2.1% with mean spatial resolutions of 7.0±1.0, 9.4±3.3 and 26.0±5.0 mm using ESR, Teflon and black paint, respectively. ESR reflector gave the best light output, energy and axial spatial resolutions. These characterization results of PSPMT-based dual-ended long LYSO crystals will be useful in the design of detector modules for a highly compact geometry preclinical PET system using this detector technology.

  2. Giant secondary grain growth in Cu films on sapphire

    Directory of Open Access Journals (Sweden)

    David L. Miller

    2013-08-01

    Full Text Available Single crystal metal films on insulating substrates are attractive for microelectronics and other applications, but they are difficult to achieve on macroscopic length scales. The conventional approach to obtaining such films is epitaxial growth at high temperature using slow deposition in ultrahigh vacuum conditions. Here we describe a different approach that is both simpler to implement and produces superior results: sputter deposition at modest temperatures followed by annealing to induce secondary grain growth. We show that polycrystalline as-deposited Cu on α-Al2O3(0001 can be transformed into Cu(111 with centimeter-sized grains. Employing optical microscopy, x-ray diffraction, and electron backscatter diffraction to characterize the films before and after annealing, we find a particular as-deposited grain structure that promotes the growth of giant grains upon annealing. To demonstrate one potential application of such films, we grow graphene by chemical vapor deposition on wafers of annealed Cu and obtain epitaxial graphene grains of 0.2 mm diameter.

  3. Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Molon, Rafael Scaf; Morais Camillo, Juliana Aparecida Najarro Dearo; Ferreira, Mauricio Goncalves; Loffredo, Leonor Castro Monteiro; Scaf, Gulnara [Araraquara Dental School, Universidade Estadual Paulista, Sao Paulo (Brazil); Sakakura, Celso Eduardo [Barretos Dental School, Barretos Educational Fundation, Sao Paulo (Brazil)

    2012-09-15

    This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC{sub 95%}:6.04-6.54) and 6.79 mm (IC{sub 95%}:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64 mm(IC{sub 95%}:6.40-6.89) and 6.79 mm(IC{sub 95%}:6.45-7.11), respectively. The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

  4. Preparation of Track Etch Membrane Filters Using Polystyrene Film

    International Nuclear Information System (INIS)

    Kaewsaenee, Jerawut; Ratanatongchai, Wichian; Supaphol, Pitt; Visal-athaphand, Pinpan

    2007-08-01

    Full text: Polystyrene nuclear track etch membrane filters was prepared by exposed 13 .m thin film polystyrene with fission fragment. Nuclear latent track was enlarged to through hole on the film by etching with 80 o C 40% H 2 SO 4 with K 2 Cr 2 O 7 solution for 6-10 hour. The hole size was depend on concentration of etching solution and etching time with 1.3-3.4 .m hole diameter. The flow rate test of water was 0.79-1.56 mm cm-2 min-1 at 109.8-113.7 kPa pressure

  5. Superlubricity and wearless sliding in diamondlike carbon films

    International Nuclear Information System (INIS)

    Erdemir, A.

    2001-01-01

    Diamondlike carbon (DLC) films have attracted great interest in recent years mainly because of their unusual optical, electrical, mechanical, and tribological properties. Such properties are currently being exploited for a wide range of engineering applications including magnetic hard disks, gears, sliding and roller bearings, scratch resistant glasses, biomedical implants, etc. Systematic studies on carbon-based materials in our laboratory have led to the development of a new class of amorphous DLC films that provide extremely low friction and wear coefficients of 0.001 to 0.005 and 10(sup -11) to 10(sup -10) mm(sup 3) /N.m, respectively, when tested in inert-gas or high-vacuum environments. These films were produced in highly hydrogenated gas discharge plasmas by a plasma enhanced chemical vapor deposition process at room temperature. The carbon source gases used in the deposition of these films included methane, acetylene, and ethylene. Tribological studies in our laboratory have established a very close correlation between the composition of the plasmas and the friction and wear coefficients of the resultant DLC films. Specifically, the friction and wear coefficients of DLC films grown in plasmas with higher hydrogen-to-carbon ratios were much lower than films derived from source gases with lower hydrogen-to-carbon ratios. Fundamental tribological and surface analytical studies have led us to conclude that hydrogen (within the film, as well as on the sliding surfaces) is extremely important for the superlubricity and wearless sliding behavior of these films. Based on these studies, a mechanistic model is proposed to explain the superlow friction and wear properties of the new DLC films

  6. A novel hierarchical ZnO disordered/ordered bilayer nanostructured film for dye sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Yamin, E-mail: yaminfengccnuphy@outlook.com; Wu, Fei; Jiang, Jian; Zhu, Jianhui; Fodjouong, Ghislain Joel; Meng, Gaoxiang; Xing, Yanmin; Wang, Wenwu; Huang, Xintang, E-mail: xthuang@phy.ccnu.edu.cn

    2013-12-25

    Graphical abstract: A novel hierarchical disordered/ordered bilayer ZnO nanostructured film in the length of 18 μm have been successfully synthesized on the FTO substrate; the hierarchical ZnO nanostructured film electrodes applied in DSSCs exhibit photoelectric conversion efficiency as high as 5.16%. Highlights: •A novel hierarchical ZnO structure film was fabricated on a FTO substrate. •Hierarchical ZnO film is applied as the electrodes for dye sensitized solar cells. •The film possess high specific surface area and fast electron transport effect. •The light-scattering effect of the hierarchical film is pronounced. •The energy conversion efficiency of hierarchical ZnO electrode reaches to 5.16%. -- Abstract: A novel hierarchical ZnO nanostructured film is synthesized via a chemical bath deposition (CBD) method followed by a treatment of thermal decomposition onto a fluorine-doped tin oxide (FTO) substrate. This hierarchical film is composed of disordered ZnO nanorods (NRs) (top layer) and ordered ZnO nanowires (NWs) (bottom layer). The products possess the following features such as high specific surface area, fast electron transport, and pronounced light-scattering effect, which are quite suitable for dye sensitized solar cells (DSSCs) applications. A light-to-electricity conversion efficiency of 5.16% is achieved when the hierarchical ZnO nanostructured film is used as the photoanode under 100 mW cm{sup −2} illumination. This efficiency is found to be much higher than that of the DSSCs with pure ordered ZnO NWs (1.45%) and disordered ZnO NRs (3.31%) photoanodes.

  7. A novel hierarchical ZnO disordered/ordered bilayer nanostructured film for dye sensitized solar cells

    International Nuclear Information System (INIS)

    Feng, Yamin; Wu, Fei; Jiang, Jian; Zhu, Jianhui; Fodjouong, Ghislain Joel; Meng, Gaoxiang; Xing, Yanmin; Wang, Wenwu; Huang, Xintang

    2013-01-01

    Graphical abstract: A novel hierarchical disordered/ordered bilayer ZnO nanostructured film in the length of 18 μm have been successfully synthesized on the FTO substrate; the hierarchical ZnO nanostructured film electrodes applied in DSSCs exhibit photoelectric conversion efficiency as high as 5.16%. Highlights: •A novel hierarchical ZnO structure film was fabricated on a FTO substrate. •Hierarchical ZnO film is applied as the electrodes for dye sensitized solar cells. •The film possess high specific surface area and fast electron transport effect. •The light-scattering effect of the hierarchical film is pronounced. •The energy conversion efficiency of hierarchical ZnO electrode reaches to 5.16%. -- Abstract: A novel hierarchical ZnO nanostructured film is synthesized via a chemical bath deposition (CBD) method followed by a treatment of thermal decomposition onto a fluorine-doped tin oxide (FTO) substrate. This hierarchical film is composed of disordered ZnO nanorods (NRs) (top layer) and ordered ZnO nanowires (NWs) (bottom layer). The products possess the following features such as high specific surface area, fast electron transport, and pronounced light-scattering effect, which are quite suitable for dye sensitized solar cells (DSSCs) applications. A light-to-electricity conversion efficiency of 5.16% is achieved when the hierarchical ZnO nanostructured film is used as the photoanode under 100 mW cm −2 illumination. This efficiency is found to be much higher than that of the DSSCs with pure ordered ZnO NWs (1.45%) and disordered ZnO NRs (3.31%) photoanodes

  8. Semi-transparent gold film as simultaneous surface heater and resistance thermometer for nucleate boiling studies

    International Nuclear Information System (INIS)

    Oker, E.; Merte, H. Jr.

    1981-01-01

    A large (22 x 25 mm) semi-transparent thin film of gold, approximately 400 A in thickness, is deposited on a glass substrate for simultaneous use as a heat source and resistance thermometer. Construction techniques and calibration procedures are described, and a sample application to a transient boiling process is included with simultaneous high speed photographs taken through the thin film from beneath

  9. PZT Thin Film Piezoelectric Traveling Wave Motor

    Science.gov (United States)

    Shen, Dexin; Zhang, Baoan; Yang, Genqing; Jiao, Jiwei; Lu, Jianguo; Wang, Weiyuan

    1995-01-01

    With the development of micro-electro-mechanical systems (MEMS), its various applications are attracting more and more attention. Among MEMS, micro motors, electrostatic and electromagnetic, are the typical and important ones. As an alternative approach, the piezoelectric traveling wave micro motor, based on thin film material and integrated circuit technologies, circumvents many of the drawbacks of the above mentioned two types of motors and displays distinct advantages. In this paper we report on a lead-zirconate-titanate (PZT) piezoelectric thin film traveling wave motor. The PZT film with a thickness of 150 micrometers and a diameter of 8 mm was first deposited onto a metal substrate as the stator material. Then, eight sections were patterned to form the stator electrodes. The rotor had an 8 kHz frequency power supply. The rotation speed of the motor is 100 rpm. The relationship of the friction between the stator and the rotor and the structure of the rotor on rotation were also studied.

  10. Preparation of YBa2Cu3O7-δ epitaxial thin films by pulsed ion-beam evaporation

    International Nuclear Information System (INIS)

    Sorasit, S.; Yoshida, G.; Suzuki, T.; Suematsu, H.; Jiang, W.; Yatsui, K.

    2001-01-01

    Thin films of YBa 2 Cu 3 O 7-δ (Y-123) grown epitaxially have been successfully deposited by ion-beam evaporation (IBE). The c-axis oriented YBa 2 Cu 3 O 7-δ thin films were successfully deposited on MgO and SrTiO 3 substrates. The Y-123 thin films which were prepared on the SrTiO 3 substrates were confirmed to be epitaxially grown, by X-ray diffraction analysis. The instantaneous deposition rate of the Y-123 thin films was estimated as high as 4 mm/s. (author)

  11. Magnetic hysteresis of cerium doped bismuth ferrite thin films

    International Nuclear Information System (INIS)

    Gupta, Surbhi; Tomar, Monika; Gupta, Vinay

    2015-01-01

    The influence of Cerium doping on the structural and magnetic properties of BiFeO 3 thin films have been investigated. Rietveld refinement of X-ray diffraction data and successive de-convolution of Raman scattering spectra of Bi 1−x Ce x FeO 3 (BCFO) thin films with x=0–0.20 reflect the single phase rhombohedral (R3c) formation for x<0.08, whereas concentration-driven gradual structural phase transition from rhombohedral (R3c) to partial tetragonal (P4mm) phase follows for x≥0.08. All low wavenumber Raman modes (<300 cm −1 ) showed a noticeable shift towards higher wavenumber with increase in doping concentration, except Raman E-1 mode (71 cm −1 ), shows a minor shift. Sudden evolution of Raman mode at 668 cm −1 , manifested as A 1 -tetragonal mode, accompanied by the shift to higher wavenumber with increase in doping concentration (x) affirm partial structural phase transition. Anomalous wasp waist shaped (M–H) hysteresis curves with improved saturation magnetization (M s ) for BCFO thin films is attributed to antiferromagnetic interaction/hybridization between Ce 4f and Fe 3d electronic states. The contribution of both hard and soft phase to the total coercivity is calculated. Polycrystalline Bi 0.88 Ce 0.12 FeO 3 thin film found to exhibit better magnetic properties with M s =15.9 emu/g without any impure phase. - Highlights: • Synthesis of single phase Bi 1−x Ce x FeO 3 thin films with (x=0–0.2) on cost effective corning glass and silicon substrates using CSD technique. • Structural modification studies using Rietveld refinement of XRD and de-convolution of Raman spectra revealed partial phase transition from rhombohedral (R3c) to tetragonal (P4mm) phase. • Possible reasons for origin of pinched magnetic behavior of BCFO thin films are identified. • Contribution of both hard and soft magnetic phase in coercivity of BCFO thin films is calculated and practical applications of such materials exhibiting pinching behavior are conferred

  12. Magnetic hysteresis of cerium doped bismuth ferrite thin films

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Surbhi [Department of Physics and Astrophysics, University of Delhi (India); Tomar, Monika [Physics Department, Miranda House, University of Delhi (India); Gupta, Vinay, E-mail: drguptavinay@gmail.com [Department of Physics and Astrophysics, University of Delhi (India)

    2015-03-15

    The influence of Cerium doping on the structural and magnetic properties of BiFeO{sub 3} thin films have been investigated. Rietveld refinement of X-ray diffraction data and successive de-convolution of Raman scattering spectra of Bi{sub 1−x}Ce{sub x}FeO{sub 3} (BCFO) thin films with x=0–0.20 reflect the single phase rhombohedral (R3c) formation for x<0.08, whereas concentration-driven gradual structural phase transition from rhombohedral (R3c) to partial tetragonal (P4mm) phase follows for x≥0.08. All low wavenumber Raman modes (<300 cm{sup −1}) showed a noticeable shift towards higher wavenumber with increase in doping concentration, except Raman E-1 mode (71 cm{sup −1}), shows a minor shift. Sudden evolution of Raman mode at 668 cm{sup −1}, manifested as A{sub 1}-tetragonal mode, accompanied by the shift to higher wavenumber with increase in doping concentration (x) affirm partial structural phase transition. Anomalous wasp waist shaped (M–H) hysteresis curves with improved saturation magnetization (M{sub s}) for BCFO thin films is attributed to antiferromagnetic interaction/hybridization between Ce 4f and Fe 3d electronic states. The contribution of both hard and soft phase to the total coercivity is calculated. Polycrystalline Bi{sub 0.88}Ce{sub 0.12}FeO{sub 3} thin film found to exhibit better magnetic properties with M{sub s}=15.9 emu/g without any impure phase. - Highlights: • Synthesis of single phase Bi{sub 1−x}Ce{sub x}FeO{sub 3} thin films with (x=0–0.2) on cost effective corning glass and silicon substrates using CSD technique. • Structural modification studies using Rietveld refinement of XRD and de-convolution of Raman spectra revealed partial phase transition from rhombohedral (R3c) to tetragonal (P4mm) phase. • Possible reasons for origin of pinched magnetic behavior of BCFO thin films are identified. • Contribution of both hard and soft magnetic phase in coercivity of BCFO thin films is calculated and practical

  13. Effect of Gallic acid on mechanical and water barrier properties of zein-oleic acid composite films.

    Science.gov (United States)

    Masamba, Kingsley; Li, Yue; Hategekimana, Joseph; Liu, Fei; Ma, Jianguo; Zhong, Fang

    2016-05-01

    In this study, the effect of gallic acid on mechanical and water barrier properties of zein-oleic acid 0-4 % composite films was investigated. Molecular weight distribution analysis was carried out to confirm gallic acid induced cross linking through change in molecular weight in fraction containing zein proteins. Results revealed that gallic acid treatment increased tensile strength from 17.9 MPa to 26.0 MPa, decreased water vapour permeability from 0.60 (g mm m(-2) h(-1) kPa(-1)) to 0.41 (g mm m(-2) h(-1) kPa(-1)), increased solubility from 6.3 % to 10.2 % and marginally increased elongation at break from 3.7 % to 4.2 % in zein films only. However, gallic acid treatment in zein-oleic composite films did not significantly influence mechanical and water barrier properties and in most instances irrespective of oleic acid concentration, the properties were negatively affected. Results from scanning electron microscopy showed that both gallic acid treated and untreated zein films and composite films containing 3 % oleic acid had a compact and homogeneous structure while those containing 4 % oleic acid had inhomogeneous structure. The findings have demonstrated that gallic acid treatment can significantly improve mechanical and water barrier properties especially in zein films only as opposed to when used in composite films using zein and oleic acid.

  14. Manufacturing Te/PEDOT Films for Thermoelectric Applications.

    Science.gov (United States)

    Culebras, Mario; Igual-Muñoz, Ana María; Rodríguez-Fernández, Carlos; Gómez-Gómez, María Isabel; Gómez, Clara; Cantarero, Andrés

    2017-06-21

    In this work, flexible Te films have been synthesized by electrochemical deposition using PEDOT [poly(3,4-ethylenedioxythiophene)] nanofilms as working electrodes. The Te electrodeposition time was varied to find the best thermoelectric properties of the Te/PEDOT double layers. To show the high quality of the Te films grown on PEDOT, the samples were analyzed by Raman spectroscopy, showing the three Raman active modes of Te: E 1 , A 1 , and E 2 . The X-ray diffraction spectra also confirmed the presence of crystalline Te on top of the PEDOT films. The morphology of the Te/PEDOT films was studied using scanning electron microscopy, showing a homogeneous distribution of Te along the film. Also an atomic force microscope was used to analyze the quality of the Te surface. Finally, the electrical conductivity and the Seebeck coefficient of the Te/PEDOT films were measured as a function of the Te deposition time. The films showed an excellent thermoelectric behavior, giving a maximum power factor of about 320 ± 16 μW m -1 K -2 after 2.5 h of Te electrochemical deposition, a value larger than that reported for thin films of Te. Qualitative arguments to explain this behavior are given in the discussion.

  15. Cholesterol biosensor based on rf sputtered zinc oxide nanoporous thin film

    International Nuclear Information System (INIS)

    Singh, S. P.; Arya, Sunil K.; Pandey, Pratibha; Malhotra, B. D.; Saha, Shibu; Sreenivas, K.; Gupta, Vinay

    2007-01-01

    Cholesterol oxidase (ChOx) has been immobilized onto zinc oxide (ZnO) nanoporous thin films grown on gold surface. A preferred c-axis oriented ZnO thin film with porous surface morphology has been fabricated by rf sputtering under high pressure. Optical studies and cyclic voltammetric measurements show that the ChOx/ZnO/Au bioelectrode is sensitive to the detection of cholesterol in 25-400 mg/dl range. A relatively low value of enzyme's kinetic parameter (Michaelis-Menten constant) ∼2.1 mM indicates enhanced enzyme affinity of ChOx to cholesterol. The observed results show promising application of nanoporous ZnO thin film for biosensing application without any functionalization

  16. HIGH-FREQUENCY MICROINDUCTOR ON THE BASE OF FLEXIBLE POLYIMIDE FILM

    Directory of Open Access Journals (Sweden)

    A. V. Petrov

    2011-01-01

    Full Text Available A method of creation of 3D flexible high-frequency microinductor on the base of polyimide film with etched swift heavy ion tracks, filled with a conducting material is proposed. This methos is more simple as compared with existing technologies. The service model of the microinductor having dimensions 0,04 mm3 is fabricated. This model has following main operational characteristics: winding density of 7 winding/mm at the winding thickness 10 μm; inductivity 0.3 mH with the Q-factor of 8 at 200 MHz. A possibility of the decrease of dimensions of the device down to 10-6 mm3 is shown. 

  17. An experimental extrapolation technique using the Gafchromic EBT3 film for relative output factor measurements in small x-ray fields

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Johnny E., E-mail: johnny.morales@lh.org.au [Department of Radiation Oncology, Chris O’Brien Lifehouse, 119-143 Missenden Road, Camperdown, NSW 2050, Australia and School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Level 4 O Block, Garden’s Point, QLD 4001 (Australia); Butson, Martin; Hill, Robin [Department of Radiation Oncology, Chris O’Brien Lifehouse, 119-143 Missenden Road, Camperdown, NSW 2050, Australia and Institute of Medical Physics, University of Sydney, NSW 2006 (Australia); Crowe, Scott B. [School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Level 4 O Block, Garden’s Point, QLD 4001, Australia and Cancer Care Services, Royal Brisbane and Women’s Hospital, Butterfield Street, Herston, QLD 4029 (Australia); Trapp, J. V. [School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Level 4 O Block, Garden’s Point, QLD 4001 (Australia)

    2016-08-15

    Purpose: An experimental extrapolation technique is presented, which can be used to determine the relative output factors for very small x-ray fields using the Gafchromic EBT3 film. Methods: Relative output factors were measured for the Brainlab SRS cones ranging in diameters from 4 to 30 mm{sup 2} on a Novalis Trilogy linear accelerator with 6 MV SRS x-rays. The relative output factor was determined from an experimental reducing circular region of interest (ROI) extrapolation technique developed to remove the effects of volume averaging. This was achieved by scanning the EBT3 film measurements with a high scanning resolution of 1200 dpi. From the high resolution scans, the size of the circular regions of interest was varied to produce a plot of relative output factors versus area of analysis. The plot was then extrapolated to zero to determine the relative output factor corresponding to zero volume. Results: Results have shown that for a 4 mm field size, the extrapolated relative output factor was measured as a value of 0.651 ± 0.018 as compared to 0.639 ± 0.019 and 0.633 ± 0.021 for 0.5 and 1.0 mm diameter of analysis values, respectively. This showed a change in the relative output factors of 1.8% and 2.8% at these comparative regions of interest sizes. In comparison, the 25 mm cone had negligible differences in the measured output factor between zero extrapolation, 0.5 and 1.0 mm diameter ROIs, respectively. Conclusions: This work shows that for very small fields such as 4.0 mm cone sizes, a measureable difference can be seen in the relative output factor based on the circular ROI and the size of the area of analysis using radiochromic film dosimetry. The authors recommend to scan the Gafchromic EBT3 film at a resolution of 1200 dpi for cone sizes less than 7.5 mm and to utilize an extrapolation technique for the output factor measurements of very small field dosimetry.

  18. Broadband Mm-Wave OFDM Communications in Doubly Selective Channel: Performance Evaluation Using Measured Mm-Wave Channel

    DEFF Research Database (Denmark)

    Chen, Xiaoming; Fan, Wei; Pedersen, Gert F.

    2018-01-01

    In this work, we evaluate the performance of the broadband millimeter-wave (mm-wave) OFDM system in the presence of phase noise (PN) of phase-locked loop based oscillator and delay spread of measured mm-wave channel. It is shown, using Akaike's information criterion, that the channel tap...... coefficients of the broadband mm-wave channel do not follow Gaussian distribution due to the broad bandwidth. It is also shown that, given a cyclic prefix (CP) length for a certain delay spread, an effective PN mitigation scheme enables a PN corrupted OFDM system to function with small subcarrier spacing and...

  19. Formation and microstructure of nickel oxide films

    Energy Technology Data Exchange (ETDEWEB)

    Marcius, Marijan [Ruder Boskovic Institute, P.O. Box 180, HR-10002 Zagreb (Croatia); Ristic, Mira, E-mail: ristic@irb.hr [Ruder Boskovic Institute, P.O. Box 180, HR-10002 Zagreb (Croatia); Ivanda, Mile; Music, Svetozar [Ruder Boskovic Institute, P.O. Box 180, HR-10002 Zagreb (Croatia)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Difference in NiO films formed on Ni plate or glass substrate were found. Black-Right-Pointing-Pointer NiO particle sizes on Ni plate changed from nano to micron dimensions. Black-Right-Pointing-Pointer NiO particle sizes on glass substrate changed from {approx}16 to {approx}27 nm. Black-Right-Pointing-Pointer Raman and UV/Vis/NIR spectra are related to the microstructure of NiO films. - Abstract: The formation and microstructure of NiO films on different substrates were monitored using XRD, Raman, UV/Vis/NIR and FE-SEM/EDS techniques. The formation of NiO films on Ni plates in air atmosphere between 400 and 800 Degree-Sign C was confirmed by XRD and Raman spectroscopy. The origin of Raman bands and corresponding Raman shifts in the samples are discussed. An increase in the size of NiO particles in the films from nano to micro dimensions was demonstrated. A change in the atomic ratio Ni:O with an increase in heating temperature was observed. Polished Ni plates coated with a thin Ni-acetate layer upon heating at high temperatures gave similar NiO microstructures on the surface like in the case of non-treated Ni plates. Glass substrates coated with thin Ni-acetate films upon heating between 400 and 800 Degree-Sign C yielded pseudospherical NiO nanoparticles. The dominant Raman band as an indicator of NiO formation on a glass substrate was shown. The formation of NiO nanoparticles on glass substrates with maximum size distribution from 16 to 27 nm in a broad temperature range from 400 to 800 Degree-Sign C can be explained by the absence of a constant source of metallic nickel which was present in the case of Ni plates.

  20. Quality assurance for multileaf collimator with radiographic film exposed by slit beam

    International Nuclear Information System (INIS)

    Ma Jinli; Jiang Guoliang; Fu Xiaolong; Liao Yuan; Wu Kailiang; Zhou Lijun

    2004-01-01

    Objective: To evaluate the role of Kodak X-OMAT-V film exposed by slit beam in the check of various leaf positions of multileaf collimator(MLC), and to check the status of Varian 26 leaf pairs MLC in the Department of Radiation Oncology in Shanghai Cancer Hospital affiliated to Fudan University. Methods: At first, some position errors of different sizes were produced for different leaves so as to determine the minimal leaf position error that could be seen on film. Then, exposure conditions including the exposure dose and source to film distance were changed to find the optimal one. Finally, a Kodak X-OMAT-V film was exposed with a leaf sequence file which was designated randomly by a physicist with leaf position errors of different sizes. After the film was developed, two doctors and two physicists were invited to observe, on blind basis, in order to determine the sensitivity and specificity of the film in the check of leaf positions. Ultimately, leaf positions of the Varian 26 leaf pairs MLC were checked, in which way, the leaf motor status and the carriage stability were checked indirectly. Results: Leaf position errors no less than 0.2 mm could be found using Kodak X-OMAT-V film under the following conditions: source to film distance 100 cm, exposure dose 25 MU, which had been considered as the optimal exposure conditions. The sensitivity and specificity of this method were 73.4% and 96.4%. Any MLC leaf position errors more than 0.2 mm could not be detected. Thus, it was deemed that all leaf motors of the Varian 26 leaf pairs MLC were well in gear and the carriages were stable. Conclusions: MLC leaf position errors can be detected by Kodak X-OMAT-V film exposed by slit beam with high accuracy, but the ability to find leaf position errors with the naked eye may vary from person to person. It is proposed that the Kodak X-OMAT-V film exposed by slit beam be used to check the MLC leaf positions, i. e. the leaf motor status and carriage stability, at regular

  1. Myocardial bridging as evaluated by 16 row MDCT

    International Nuclear Information System (INIS)

    Canyigit, Murat; Hazirolan, Tuncay; Karcaaltincaba, Musturay; Dagoglu, Merve Gulbiz; Akata, Deniz; Aytemir, Kudret; Oto, Ali; Balkanci, Ferhun; Akpinar, Erhan; Besim, Aytekin

    2009-01-01

    Purpose: The purpose of this study is to find out the prevalence, appearance and clinical symptoms of myocardial bridging (MB) by MDCT coronary angiography (CTA). Materials and methods: A total of 280 (50 females) consecutive patients followed with coronary artery disease or postoperative stent and bypass control, underwent CTA performed by 16-MDCT scanner between January 2006 and April 2006. Short axis multiplanar reformatted images were evaluated. MBs were classified as complete and incomplete bridges with respect to continuity of the myocardium over the tunneled segment of left anterior descending artery (LAD) in interventricular groove and the cut-off value is 1.3 mm. Patients diagnosed with MB on CTA who had prior catheter angiography studies were re-evaluated for the presence of MB. Results: One hundred and twenty MBs [98 (81.6%) on LAD, 2 (1.6%) on diagonal branch, 11 (9.1%) on obtuse marginal, 4 (3.3%) on right coronary artery, 5 (4.1%) on ramus intermedius artery] were detected in 108 (38.5%) patients. Eighty-five (70.8%) of bridged segments in 79 (28.2%) patients were complete and the rest [35 (29.2%) in 34 (12.1%) patients] were incomplete. In 12 patients two MBs (either on different arteries or on the same artery) were detected. The length of bridged segments in patients with complete and incomplete MBs varied between 4-50.9 mm (mean 18 mm) and 4-37.3 mm (mean 13.6 mm), respectively, and the depth of myocardium over the artery ranged between 1-6.4 mm (mean 2.3 mm) and 1-1.2 mm (mean 1 mm), respectively. Thirty (27.7%) out of 108 patients, in whom MB was detected on CTA, were found to have correlative catheter angiography studies, retrospectively and MB was detected only in 4 (13.3%) out of 30 patients. Conclusion: MDCT coronary angiography is a non-invasive, efficient method in the diagnosis of MB avoiding the procedural risks that catheter angiography carries. MDCT coronary angiography allows direct visualization of the bridge itself and may thus give

  2. The Quality of Edible Film Made from Nile Tilapia (Oreochromis niloticus) Skin Gelatin with Addition of Different Type Seaweed Hydrocolloid

    Science.gov (United States)

    Deanti, H.; Hulu, J. M.; Setyaji, A.; Eliyanti, R. N.; Aliya, K.; Dewi, E. N.

    2018-02-01

    The functional properties of fish skin’s gelatin lower than mammals, hence the gelatin proteins needed a polysaccharides hydrocolloids to form a continuous and more cohesive network of edible film. Polysaccharides hydrocolloid (carrageenan, agar and alginate) containing phenol compounds was oxidized to be converted into quinone and it was expected to act as a cross linking agent. The purpose of this study was to determine the characteristics (thickness, tensile strength, elongation, solubility and water vapour transmition rate) of edible film made from nile tilapia skin gelatin by adding different type polyssacharide hydrocolloid. Edible film was made by mixture of gelatin 5 g and addition of carrageenan (C1), agar (C2), alginate (C3) concentration ; 0,5% (v/w), all the materials were poured into 100 ml destilled water that containing 10% glycerol (w/w). The solution was then heated on a hot plate stirer at 40°C for 30 min and dehydrated in a oven at 50°C. All data were analysed using ANAVA. Based on the result it can be seen that the addition of oxidized polisacarides hydrocolloid have a significant effect on tensile strength (TS), water vapor transmision rate, solubility and elongation at break properties, but did not in thickness. Edible film gelatin with the addition of alginate has better characteristics viewed by tensile strength (23.05 Kgf/cm2), water vapor transmission rate (0.61 gram/m2/hour) and thickness (0.16 mm) than carrageenan and agar.

  3. In vitro comparison between the image obtained using PSP plates and Kodak E-speed films.

    Science.gov (United States)

    Petel, R; Yaroslavsky, L; Kaffe, I

    2014-07-01

    The aim of this study was to compare the intra-oral radiographic images obtained by a PSP digital radiography system ("Orex", Israel) with that obtained using Kodak Ultra speed films in terms of image quality, radiation dosage and diagnostic value. The physical measurement of image quality was conducted with an aluminum step-wedge. Radiation dosage was measured with a dosimeter. Fog and base levels were measured by developing unexposed films and scanning unexposed PSP plates. The in vitro model included preparation and radiographic evaluation of approximal artificial lesions in premolars and molars in depths ranging from 0.25 mm to 1.00 mm. Radiographs were evaluated for the existence of a lesion and its size by 8 experienced clinicians. Relative contrast was similar in both methods. The resolving power of the digital system was lower than that of the E-speed film. As for the subjective evaluation of artificial lesions, there was no significant difference between the two methods excluding those tooth images without lesions, where the analog method was found to be more accurate. The PSP system ("Orex") provides good image quality and diagnostic information with reduced exposure when compared with E-speed film.

  4. Derivation of space groups in mm2, 222 and mmm crystal classes

    International Nuclear Information System (INIS)

    Nigam, G.D.

    1987-08-01

    An algebraic approach is developed to derive space groups using 4x4 Seitz matrices for the crystal classes mm2, 222 and mmm in the orthorhombic system. The advantage of the present method is that it is relatively simple and can be adapted to introduce space groups to beginners. One of the advantages of the present method is that it admits a geometrical visualization of the symmetry elements of space group. The method can easily be extended to other crystal classes in a straightforward way. 16 refs, 1 fig., 2 tabs

  5. Preparation and evaluation of periodontal films based on polyelectrolyte complex formation.

    Science.gov (United States)

    Kassem, Abeer Ahmed; Ismail, Fatma Ahmed; Naggar, Viviane Fahim; Aboulmagd, Elsayed

    2015-05-01

    Local intra-pocket drug delivery devices can provide an effective concentration of the antimicrobial agent at the site of action with avoidance of undesirable side effects. This study explored the application of chitosan-alginate and chitosan-pectin polyelectrolyte complex (PEC) films as drug release regulators for tetracycline HCl (Tc) to treat periodontal pockets. Periodontal films with 1:1 Tc:PEC ratio were prepared using 1:1 chitosan (Ch) to sodium alginate (A) or 1:3 Ch to pectin (P). The scanning electron microscope showed acceptable film appearance and differential scanning calorimetry analysis confirmed complex formation. The in vitro release studies for both films showed a burst drug release, followed by prolonged release for 70 h. A prolonged antibacterial activity of both films against Staphylococcus aureus ATCC 6538 was observed over a period of 21 days. Aging studies indicated that the five months storage period in freezer did not significantly influence the drug release profile or the antibacterial activity of both films. Clinical evaluation showed a significant reduction in pocket depth (p < 0.0001) to their normal values (≤3 mm). PEC films could be exploited as a prolonged drug release devices for treatment of periodontal pockets.

  6. Numerical analysis for conductance probes, for the measurement of liquid film thickness in two-phase flow

    International Nuclear Information System (INIS)

    No, Hee Cheon; Mayinger, F.

    1995-01-01

    A three-dimensional numerical tool is developed to calculate the potential distribution, electric field, and conductance for any types of conductance probes immersed in the wavy liquid film with various shapes of its free surface. The tool is validated against various analytical solutions. It is applied to find out the characteristics of the wire-wire probe, the flush-wire probe and the flush-flush probe in terms of resolution, linearity, and sensitivity. The wire-wire probe shows high resolution and excellent linearity for various film thickness, but comparably low sensitivity for low film thickness fixed. The flush-wire probe shows good linearity and high sensitivity for varying film thickness, but resolution degrading with an increase in film thickness. In order to check the applicability of the three types of probes in the real situation, the Korteweg-de Vries(KdV) two-dimensional solitary wave is simulated. The wire-wire probe is strongly affected by the installation direction of the two wires; when the wires are installed perpendicularly to the flow direction, the wire-wire probe shows large distortion of the solitary wave. In order to measure the transverse profile of waves, the wire-wire probes and the flush-wire probes are required to be separately installed 2mm and 2mm, respectively

  7. Electrochemical fabrication of a cauliflower-like nanostructured Pd film from pure Pd and its applications in electrocatalysis and electroanalysis

    International Nuclear Information System (INIS)

    Xu, Shili; Zhang, Hefang; Huang, Fuli; Wang, Pengshu; Xia, Yue; Li, Zelin; Huang, Wei

    2013-01-01

    Highlights: • A cauliflower-like nanostructured Pd film was fabricated by just applying one double-potential step method. • The film fabrication involves the formation of K 2 PdCl 4 salt from pure Pd and its electroreduction to Pd atoms. • The film electrode exhibits high electrocatalytic activities toward the oxidation of ethanol and ascorbic acid. • Good analytical performances in the higher-concentration regions are obtained on the film electrode. -- Abstract: A cauliflower-like nanostructured Pd film (CNPF) has been fabricated by just applying one double-potential step on a pure Pd substrate in a KCl solution. The CNPF formation mainly involves the formation of K 2 PdCl 4 salt from pure Pd and its electroreduction to Pd atoms. The as-prepared CNPF electrode exhibits high electrocatalytic activities toward the oxidation of ethanol and ascorbic acid (AA). The CNPF electrode is also employed to detect AA by means of constant potential amperometry (CPA) and cyclic voltammetry (CV), and good analytical performances in the higher-concentration regions are obtained. In CPA studies performed at −0.4 V, the oxidation current is linearly dependent on AA concentration in the range of 0.1–7.5 mM with a detection limit of 80 μM (based on S/N = 3), a short response time of about 3 s and a high sensitivity of 589.80 μA mM −1 cm −2 . Meanwhile, the peak current responses in CVs are linear over the broad range of 0.1–35 mM with a sensitivity of 178.56 μA mM −1 cm −2 . Besides, the CNPF electrode can also be used to detect AA in medicine vitamin C tablet with satisfactory results

  8. Composite polyaniline/calixarene Langmuir - Blodgett films for gas sensing

    Science.gov (United States)

    Lavrik, N. V.; DeRossi, D.; Kazantseva, Z. I.; Nabok, A. V.; Nesterenko, B. A.; Piletsky, S. A.; Kalchenko, V. I.; Shivaniuk, A. N.; Markovskiy, L. N.

    1996-12-01

    Mixtures of the polyaniline (emeraldine base) and phosphorylated calix[4]resorcinolarene derivative (CA) are proposed to prepare LB films for conductometric gas sensors. They are quite stable at the air - water interface and give LB films of high quality. The average thickness of the mixed monolayers is found to be 1.6 nm. The as-deposited films are insulating. Doping with HCl increases the conductivity up to between 0957-4484/7/4/002/img12 and 0957-4484/7/4/002/img13 which depends on the component ratio. The films containing more than 20 wt% of CA are doped reversibly in part. Thus, the films which are highly sensitive to either 0957-4484/7/4/002/img14 or HCl films are prepared by choosing the component ratio. Detection of 0957-4484/7/4/002/img14 and HCl in the ppm range is demonstrated.

  9. SU-E-T-476: Quality Assurance for Gamma Knife Perfexion Using the Exradin W1 Plastic Scintillation Detector

    Energy Technology Data Exchange (ETDEWEB)

    Pino, R [Houston Methodist Hospital (United States); Therriault-Proulx, F; Yang, J; Beddar, S [University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-01

    Purpose: To perform dose profile and output factor measurements for the Exradin W1 plastic scintillation detector (PSD) for the Gamma Knife Perfexion (GKP) collimators in a Lucy phantom and to compare these values to an Exradin A16 ion chamber, EBT3 radiochromic film and treatment planning system (TPS) data. Methods: We used the Exradin W1 PSD which has a small volume, near-water equivalent sensitive element. It has also been shown to be energy independent. This new detector is manufactured and distributed by Standard Imaging, Inc. Measurements were performed for all three collimators (4 mm, 8 mm and 16 mm) for the GKP. The Lucy phantom with the PSD inserted was moved in small steps to acquire profiles in all three directions. EBT3 film was inserted in the Lucy phantom and exposed to a single shot for each collimator. Relative output factors were measured using the three detectors while profiles acquired with the PSD were compared to the ones measured with EBT3 radiochromic film. Results: Measured output factors relative to the largest collimator are as followsCollimator PS EBT3 A1616mm 1.000 1.000 1.0008mm 0.892 0.881 0.8834mm 0.795 0.793 0.727 The nominal (vendor) OFs for GKP are 1.000, 0.900, and 0.814, for collimators 16 mm, 8 mm and 4 mm, respectively. There is excellent agreement between all profiles measured with the PSD and EBT3 as well as with the TPS data provided by the vendor. Conclusion: Output factors measured with the W1 were consistent with the ones measured with EBT3 and A16 ion chamber. Measured profiles are in excellent agreement. The W1 detector seems well suited for beam QA for Gamma Knife due to its dosimetric characteristics. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field Radiotherapy”.

  10. Properties of polyvinyl alcohol/xylan composite films with citric acid.

    Science.gov (United States)

    Wang, Shuaiyang; Ren, Junli; Li, Weiying; Sun, Runcang; Liu, Shijie

    2014-03-15

    Composite films of xylan and polyvinyl alcohol were produced with citric acid as a new plasticizer or a cross-linking agent. The effects of citric acid content and polyvinyl alcohol/xylan weight ratio on the mechanical properties, thermal stability, solubility, degree of swelling and water vapor permeability of the composite films were investigated. The intermolecular interactions and morphology of composite films were characterized by FTIR spectroscopy and SEM. The results indicated that polyvinyl alcohol/xylan composite films had good compatibility. With an increase in citric acid content from 10% to 50%, the tensile strength reduced from 35.1 to 11.6 MPa. However, the elongation at break increased sharply from 15.1% to 249.5%. The values of water vapor permeability ranged from 2.35 to 2.95 × 10(-7)g/(mm(2)h). Interactions between xylan and polyvinyl alcohol in the presence of citric acid become stronger, which were caused by hydrogen bond and ester bond formation among the components during film forming. Copyright © 2013. Published by Elsevier Ltd.

  11. Produtos em filme – Inovação na tecnologia de cosméticos = Film products - Innovation in cosmetics technology

    Directory of Open Access Journals (Sweden)

    Andreia Maria Sanfelice

    2010-01-01

    Full Text Available A indústria cosmética tem investido fortemente na pesquisa e no desenvolvimento de novos produtos, para melhor atender as exigências do consumidor. Como inovação neste segmento têm despontado os cosméticos em filme. A partir de uma fórmula inicial, contendo como formador de película um polissacarídeo constituído de maltotriose e como agente gelificante sodium polyacrylate, foram obtidos géis viscosos que foram espalhados em placas de vidro, de maneira a se obter filmes de 1 mm de espessura. Após secagem à temperatura ambiente, os mesmos foram recortados (1 cm2 e acondicionados. Várias alterações foram realizadas a fim de se obter um filme flexível, com rigidez adequada, ausência de rachaduras e de bolhas, fácil dissolução em água e sensorial agradável. As formulações foram submetidas a diferentes temperaturas para avaliação preliminar da estabilidade. Foram desenvolvidos dois produtos, um contendo extratos hidroglicólicos de Aloe Vera e de Rosa Branca, auxiliares no tratamento da acne, e outro contendo extratos hidroglicólicos de Camomila e de Pera, auxiliares no combate a olheiras. Pequenos, leves e finos, os cosméticos em filme representam inovação que pode ocupar o lugar de produtos tradicionais, por proporcionarem maior praticidade e facilidade de uso e de transporte, mantendo a eficácia e a segurança necessárias a um cosmético.The cosmetics industry has invested heavily in the research and development of new products, to satisfy consumer demands. As a result of the innovation in this sector, cosmetics have emerged in film format. Starting from an initial formula containing a polysaccharide consisting of maltotriose units as a film former and sodium polyacrylate as gelling agent, viscous gels were obtained and dispersed in glass plate, in order to obtain 1 mm thick films. After drying to room temperature, they were cut out (1 cm2 and conditioned. Various alterations were carried out in order to obtain a

  12. Polyether ether ketone encased monolith frits made of polyether ether ketone tubing with a 0.25 mm opening resulting in an improved separation performance in liquid chromatography.

    Science.gov (United States)

    Park, Sin Young; Cheong, Won Jo

    2016-05-01

    Tiny polyether ether ketone encased monolith frits have been prepared by modified catalytic sulfonation of the inner surface of polyether ether tubing (1.6 mm od, 0.25 mm id) followed by modified formation of organic monolith and cutting of the tubing into slices. The frit was placed below the central hole of the column outlet union and supported by a combination of a silica capillary (0.365 mm od, 0.05 mm id) and a polyether ether ketone sleeve (1.6 mm od, 0.38 mm id) tightened with a nut and a ferrule when the column was packed to prevent sinking of the frit element into the union hole (0.25 mm opening) otherwise. The column packed this way with the frits investigated in this study has shown better separation performance owing to the reduced frit volume in comparison to the column packed with a commercial stainless-steel screen frit. This study establishes the strategy of disposable microcolumns in which cheap disposable frits are used whenever the column is re-packed to yield columns of even better chromatographic performance than the columns with commercial frits. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Radiographic film: surface dose extrapolation techniques

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW; Currie, M.

    2004-01-01

    Full text: Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate 2 dimensional map of surface dose if required. Results have shown that surface % dose can be estimated within ±3% of parallel plate ionisation chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10cm, 20cmand 30cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. Corresponding parallel plate ionisation chamber measurement are 16%, 27% and 37% respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  14. Burn-out, Circumferential Film Flow Distribution and Pressure Drop for an Eccentric Annulus with Heated Rod

    DEFF Research Database (Denmark)

    Andersen, P. S.; Jensen, A.; Mannov, G.

    1974-01-01

    Measurements of (1) burn-out, (2) circumferential film flow distribution, and (3) pressure drop in a 17 × 27.2 × 3500 mm concentric and eccentric annulus geometry are presented. The eccentric displacement was varied between 0 and 3 mm. The working fluid was water. Burn-out curves at 70 bar...... flow variation on burn-out is discussed....

  15. Anisotropic strain relaxation in (Ba0.6Sr0.4)TiO3 epitaxial thin films

    Science.gov (United States)

    Simon, W. K.; Akdogan, E. K.; Safari, A.

    2005-05-01

    We have studied the evolution of anisotropic epitaxial strains in ⟨110⟩-oriented (Ba0.60Sr0.40)TiO3 paraelectric (m3m) thin films grown on orthorhombic (mm2) ⟨100⟩-oriented NdGaO3 by high-resolution x-ray diffractometry. All the six independent components of the three-dimensional strain tensor were measured in films with 25-1200-nm thickness, from which the principal stresses and strains were obtained. Pole figure analysis indicated that the epitaxial relations are [001]m3m‖[001]mm2 and [1¯10]m3m‖[010]mm2 in the plane of the film, and [110]m3m‖[100]mm2 along the growth direction. The dislocation system responsible for strain relief along [001] has been determined to be ∣b ∣(001)=3/4∣b∣. Strain relief along the [1¯10] direction, on the other hand, has been determined to be due to a coupled mechanism given by ∣b∣(1¯10)=∣b∣ and ∣b∣(1¯10)=√3 /4∣b∣. Critical thicknesses, as determined from nonlinear regression using the Matthews-Blakeslee equation, for misfit dislocation formation along [001] and [1¯10] direction were found to be 5 and 7 nm, respectively. The residual strain energy density was calculated as ˜2.9×106J/m3 at 25 nm, which was found to relax an order of magnitude by 200 nm. At 200 nm, the linear dislocation density along [001] and [1¯10] are ˜6.5×105 and ˜6×105cm-1, respectively. For films thicker than 600 nm, additional strain relief occurred through surface undulations, indicating that this secondary strain-relief mechanism is a volume effect that sets in upon cooling from the growth temperature.

  16. Smoothing of ZnO films by gas cluster ion beam

    International Nuclear Information System (INIS)

    Chen, H.; Liu, S.W.; Wang, X.M.; Iliev, M.N.; Chen, C.L.; Yu, X.K.; Liu, J.R.; Ma, K.; Chu, W.K.

    2005-01-01

    Planarization of wide-band-gap semiconductor ZnO surface is crucial for thin-film device performance. In this study, the rough initial surfaces of ZnO films deposited by r.f. magnetron sputtering on Si substrates were smoothed by gas cluster ion beams. AFM measurements show that the average surface roughness (R a ) of the ZnO films could be reduced considerably from 16.1 nm to 0.9 nm. Raman spectroscopy was used to monitor the structure of both the as-grown and the smoothed ZnO films. Rutherford back-scattering in combination with channeling effect was used to study the damage production induced by the cluster bombardment

  17. Antimicrobial nanostructured starch based films for packaging.

    Science.gov (United States)

    Abreu, Ana S; Oliveira, M; de Sá, Arsénio; Rodrigues, Rui M; Cerqueira, Miguel A; Vicente, António A; Machado, A V

    2015-09-20

    Montmorillonite modified with a quaternary ammonium salt C30B/starch nanocomposite (C30B/ST-NC), silver nanoparticles/starch nanocomposite (Ag-NPs/ST-NC) and both silver nanoparticles/C30B/starch nanocomposites (Ag-NPs/C30B/ST-NC) films were produced. The nanoclay (C30B) was dispersed in a starch solution using an ultrasonic probe. Different concentrations of Ag-NPs (0.3, 0.5, 0.8 and 1.0mM) were synthesized directly in starch and in clay/starch solutions via chemical reduction method. Dispersion of C30B silicate layers and Ag-NPs in ST films characterized by X-ray and scanning electron microscopy showed that the presence of Ag-NPs enhanced clay dispersion. Color and opacity measurements, barrier properties (water vapor and oxygen permeabilities), dynamic mechanical analysis and contact angle were evaluated and related with the incorporation of C30B and Ag-NPs. Films presented antimicrobial activity against Staphylococcus aureus, Escherichia coli and Candida albicans without significant differences between Ag-NPs concentrations. The migration of components from the nanostructured starch films, assessed by food contact tests, was minor and under the legal limits. These results indicated that the starch films incorporated with C30B and Ag-NPs have potential to be used as packaging nanostructured material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Development and characterization of edible films based on mucilage of Opuntia ficus-indica (L.).

    Science.gov (United States)

    Espino-Díaz, Miguel; de Jesús Ornelas-Paz, J; Martínez-Téllez, Miguel A; Santillán, Carlos; Barbosa-Cánovas, Gustavo V; Zamudio-Flores, Paul B; Olivas, Guadalupe I

    2010-08-01

    Mucilage of Opuntia ficus-indica (OFI) was extracted and characterized by its composition and molecular weight distribution. Mucilage film-forming dispersions were prepared under different pHs (3, 4, 5.6, 7, and 8) and calcium concentration (0% and 30% of CaCl(2), with respect to mucilage's weight), and their particle size determined. Mucilage films with and without calcium (MFCa and MF, respectively) were prepared. The effect of calcium and pH on mucilage films was evaluated determining thickness, color, water vapor permeability (WVP), tensile strength (TS), and percentage of elongation (%E). The average molecular weight of the different fractions of mucilage was: 3.4 x 10(6) (0.73%), 1 x 10(5) (1.46%), 1.1 x 10(3) (45.79%), and 2.4 x 10(2) Da (52.03%). Aqueous mucilage dispersions with no calcium presented particles with an average size d(0.5) of 15.4 microm, greater than the dispersions with calcium, 13.2 microm. MFCa films showed more thickness (0.13 mm) than the MF films (0.10 mm). The addition of calcium increased the WVP of the films from 109.94 to 130.45 gmm/m(2)dkPa. Calcium and pH affected the mechanical properties of the films; the largest TS was observed on MF films, whereas the highest %E was observed on MFCa films. The highest differences among MF and MFCa films were observed at pHs 5.6 and 7 for TS and at pHs 4 and 8 for %E. No effect of pH and calcium was observed on luminosity and hue angle. Chroma values were higher for MF when compared with MFCa, and increased as pH of the films increased. Practical Application: In this study mucilage from nopal was extracted and characterized by its ability to form edible films under different pHs, and with or without the addition of calcium. Opuntia ficus-indica mucilage had the ability to form edible films. In general, it can be considered that mucilage films without modification of pH and without the addition of calcium have the best water vapor barrier properties and tensile strength. Mucilage from nopal

  19. Chemical composition, water vapor permeability, and mechanical properties of yuba film influenced by soymilk depth and concentration.

    Science.gov (United States)

    Zhang, Siran; Lee, Jaesang; Kim, Yookyung

    2018-03-01

    Yuba is a soy protein-lipid film formed during heating of soymilk. This study described yuba as an edible film by analyzing its chemical composition, water vapor permeability (WVP), and mechanical properties. Three yuba films were prepared by using different concentrations and depths of soymilk: HS (86 g kg -1 and 2.3 cm), LS (70 g kg -1 and 2.3 cm), and LD (70 g kg -1 and 3.0 cm). As yuba was successively skimmed, the protein, lipid, and SH content decreased, but carbohydrate and SS content increased. Though both the initial concentration and the depth of soymilk affect the properties of the films, the depth of soymilk influences WVP and tensile strength (TS) more. The WVP of the HS and LS changed the least (13-17 g mm kPa -1 m -2 day 1 ), while that of the LD changed the most (13-35 g mm kPa -1 m -2 day -1 ). There were no differences (P > 0.05) in the TS between the HS and LS. LD had the greatest decrease of TS and the lowest TS among the groups. The earlier the yuba films were collected, the greater the elongation of the films was: 129% (HS), 113% (LS), and 155% (LD). The initial concentration and the depth of soymilk changed the chemical composition and structure of the yuba films. The LS yuba produced more uniform edible films with good mechanical properties. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  20. QM/MM hybrid calculation of biological macromolecules using a new interface program connecting QM and MM engines

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, Yohsuke; Tateno, Masaru [Graduate School of Pure and Applied Sciences, University of Tsukuba, Tennodai 1-1-1, Tsukuba Science City, Ibaraki 305-8571 (Japan); Ohta, Takehiro [Center for Computational Sciences, University of Tsukuba, Tennodai 1-1-1, Tsukuba Science City, Ibaraki 305-8577 (Japan)], E-mail: tateno@ccs.tsukuba.ac.jp

    2009-02-11

    An interface program connecting a quantum mechanics (QM) calculation engine, GAMESS, and a molecular mechanics (MM) calculation engine, AMBER, has been developed for QM/MM hybrid calculations. A protein-DNA complex is used as a test system to investigate the following two types of QM/MM schemes. In a 'subtractive' scheme, electrostatic interactions between QM/MM regions are truncated in QM calculations; in an 'additive' scheme, long-range electrostatic interactions within a cut-off distance from QM regions are introduced into one-electron integration terms of a QM Hamiltonian. In these calculations, 338 atoms are assigned as QM atoms using Hartree-Fock (HF)/density functional theory (DFT) hybrid all-electron calculations. By comparing the results of the additive and subtractive schemes, it is found that electronic structures are perturbed significantly by the introduction of MM partial charges surrounding QM regions, suggesting that biological processes occurring in functional sites are modulated by the surrounding structures. This also indicates that the effects of long-range electrostatic interactions involved in the QM Hamiltonian are crucial for accurate descriptions of electronic structures of biological macromolecules.

  1. Influence of Striking Edge Radius (2 mm versus 8 mm) on Instrumented Charpy Data and Absorbed Energies

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.

    2008-08-15

    The most commonly used test standards for performing Charpy impact tests (ISO 148 and ASTM E 23) envisage the use of strikers having different radii of the striking edge, i.e. 2 mm (ISO) and 8 mm (ASTM). The effect of striker geometry on Charpy results was extensively studied in the past in terms of absorbed energy measured by the machine encoder, but few investigations are available on the influence of striker configuration on the results of instrumented Charpy tests (characteristic forces, displacements and integrated energy). In this paper, these effects are investigated based on the analysis of published results from three interlaboratory studies and some unpublished Charpy data obtained at SCK-CEN. The instrumented variables which are the most sensitive to the radius of the striking edge are the maximum force and its corresponding displacement, with 8mm-strikers providing systematically higher values. Absorbed energies, obtained both from the instrumented trace and from the pendulum encoder, are almost insensitive to the type of striker up to 200 J. For higher energy levels, the values obtained from 8mm strikers become progressively larger. Data scatter is generally higher for 2mm-strikers.

  2. Precise measurement of the transverse piezoelectric coefficient for thin films on anisotropic substrate

    International Nuclear Information System (INIS)

    Chun, Doo-Man; Sato, Masashi; Kanno, Isaku

    2013-01-01

    In this study, we propose a reliable measurement method for the effective transverse piezoelectric coefficient for thin films especially on anisotropic substrate. This coefficient for piezoelectric Pb(Zr, Ti)O 3 (PZT) thin films was calculated by measuring the electric field-induced tip displacement of unimorph cantilevers composed of PZT thin films and Si substrates. We evaluated the reliability of the proposed measurement method by comparing it with numerical analysis and confirmed that the relative error of the piezoelectric coefficient (e 31,f ) was less than 1%. We prepared 16 different unimorph cantilevers composed of identical PZT films on different Si beam geometries that had various substrate thicknesses and cantilever widths. Although the effective transverse piezoelectric coefficient e 31,f of PZT thin films ranged from −6.5 to −14 C/m 2 as a function of the applied voltage, the difference among the 16 samples with an applied voltage of 25 V was within 10%. These results demonstrate that the proposed measurement method has sufficient reliability and can be used to evaluate the effective transverse piezoelectric coefficient e 31,f of thin films.

  3. The mm-wave compact component of AGN

    Science.gov (United States)

    Behar, Ehud; Vogel, Stuart; Baldi, Ranieri D.; Smith, Krista L.; Mushotzky, Richard F.

    2018-05-01

    mm-wave emission from Active Galactic Nuclei (AGN) may hold the key to understanding the physical origin of their radio cores. The correlation between radio/mm and X-ray luminosity may suggest a similar physical origin of the two sources. Since synchrotron self absorption decreases with frequency, mm-waves probe smaller length scales than cm-waves. We report on 100 GHz (3 mm) observations with CARMA of 26 AGNs selected from the hard X-ray Swift/BAT survey. 20/26 targets were detected at 100 GHz down to the 1 mJy (3σ) sensitivity, which corresponds to optically thick synchrotron source sizes of 10-4 - 10-3 pc. Most sources show a 100 GHz flux excess with respect to the spectral slope extrapolated from low frequencies. This mm spectral component likely originates from smaller scales than the few-GHz emission. The measured mm sources lie roughly around the Lmm (100 GHz) ˜10-4LX (2-10 keV) relation, similar to a few previously published X-ray selected sources, and hinting perhaps at a common coronal origin.

  4. Broadband Mm-Wave OFDM Communications in Doubly Selective Channel: Performance Evaluation Using Measured Mm-Wave Channel

    DEFF Research Database (Denmark)

    Chen, Xiaoming; Fan, Wei; Pedersen, Gert F.

    2018-01-01

    coefficients of the broadband mm-wave channel do not follow Gaussian distribution due to the broad bandwidth. It is also shown that, given a cyclic prefix (CP) length for a certain delay spread, an effective PN mitigation scheme enables a PN corrupted OFDM system to function with small subcarrier spacing and......In this work, we evaluate the performance of the broadband millimeter-wave (mm-wave) OFDM system in the presence of phase noise (PN) of phase-locked loop based oscillator and delay spread of measured mm-wave channel. It is shown, using Akaike's information criterion, that the channel tap......, therefore, small CP overhead, with only slight degradation of the error rate performance....

  5. Direct imaging of dopant distribution in polycrystalline ZnO films

    Czech Academy of Sciences Publication Activity Database

    Lorenzo, F.; Aebersold, A.B.; Morales-Masis, M.; Ledinský, Martin; Escrig, S.; Vetushka, Aliaksi; Alexander, D.T.L.; Hessler-Wyser, A.; Fejfar, Antonín; Hébert, C.; Nicolay, S.; Ballif, C.

    2017-01-01

    Roč. 9, č. 8 (2017), s. 7241-7248 ISSN 1944-8244 R&D Projects: GA ČR GC16-10429J Institutional support: RVO:68378271 Keywords : dopant distribution * film polarity * grain boundaries * NanoSIMS * polycrystalline film * zinc oxide Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 7.504, year: 2016

  6. Interferometer for measuring the dynamic surface topography of a human tear film

    Science.gov (United States)

    Primeau, Brian C.; Greivenkamp, John E.

    2012-03-01

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. Following a blink, the tear film quickly smoothes and starts to become irregular after 10 seconds. This irregularity can affect comfort and vision quality. An in vivo method of characterizing dynamic tear films has been designed based upon a near-infrared phase-shifting interferometer. This interferometer continuously measures light reflected from the tear film, allowing sub-micron analysis of the dynamic surface topography. Movies showing the tear film behavior can be generated along with quantitative metrics describing changes in the tear film surface. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or corneal topography and provides better sensitivity and resolution than shearing interferometry methods. The interferometer design is capable of identifying features in the tear film much less than a micron in height with a spatial resolution of about ten microns over a 6 mm diameter. This paper presents the design of the tear film interferometer along with the considerations that must be taken when designing an interferometer for on-eye diagnostics. Discussions include eye movement, design of null optics for a range of ocular geometries, and laser emission limits for on-eye interferometry.

  7. Diagnosis of bronchiectasis with multislice spiral CT: accuracy of 3-mm-thick structured sections

    Energy Technology Data Exchange (ETDEWEB)

    Remy-Jardin, Martine; Amara, Assia; Campistron, Philippe; Mastora, Ioana; Remy, Jacques [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France); Delannoy, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France)

    2003-05-01

    The aim of this study was to evaluate the accuracy of 3-mm-thick reconstructed sections in the diagnosis of bronchiectasis with multislice CT (MSCT). Forty consecutive patients suspected of bronchiectasis (23 females, 17 males; mean age 51 years) underwent MSCT of the entire thorax with a 4 x 1-mm collimation (120 kV, 0.5 s/rotation, 80 mAs/slice) and a pitch of 1.75. From each data set (mean z-axis coverage: 257 mm; mean duration: 21 s), two series of images were systematically generated: 1-mm (group 1) and 3-mm (group 2)-thick reconstructed scans. Both series of images were obtained at 10-mm intervals and reconstructed with a high-spatial-frequency algorithm. Two observers independently analyzed the presence of bronchiectasis and associated abnormalities in group-1 and group-2 lung images. No significant difference between group 1 and group 2 was found in: (a) the detection of bronchiectasis, identified in 24 patients (60%) in group 1 and in 23 patients (57.5%) in group 2 (p=0.08); (b) the evaluation of the extent of bronchiectasis, identifying focal bronchiectasis in 10 patients (25%) in group 1 and 7 patients (17.5%) in group 2 (p=0.39) and multifocal bronchiectasis in 16 patients (40%) in both groups; (c) the characterisation of bronchiectasis (cylindral bronchiectasis: group 1, n=24, 60%; group 2, n=21, 53%, p=0.08); varicose bronchiectasis: group 1, n=5, 12.5%; group 2, n=6, 15%, p=0.56; and cystic bronchiectasis: group 1, n=2, 5%; group 2, n=2, 5%. Apart from the identification of abnormal bronchial wall thickening (group 2, n=35, 87.5%, vs group 1, n=31, 77.5%, p<0.05), recognition of associated bronchopulmonary anomalies did not differ between the two groups. This study demonstrates a comparable accuracy of the 3- and 1-mm-thick reconstructed scans in the detection and characterization of bronchiectasis. These results suggest the potential usefulness of 3-mm-thick scans generated from 4 x 2.5-mm acquisitions in the screening of bronchiectasis, which would

  8. Lipase immobilized on nanostructured cerium oxide thin film coated on transparent conducting oxide electrode for butyrin sensing

    International Nuclear Information System (INIS)

    Panky, Sreedevi; Thandavan, Kavitha; Sivalingam, Durgajanani; Sethuraman, Swaminathan; Krishnan, Uma Maheswari; Jeyaprakash, Beri Gopalakrishnan; Rayappan, John Bosco Balaguru

    2013-01-01

    Nanostructured cerium oxide (CeO 2 ) thin films were deposited on transparent conducting oxide (TCO) substrate using spray pyrolysis technique with cerium nitrate salt, Ce(NO 3 ) 3 ·6H 2 O as precursor. Fluorine doped cadmium oxide (CdO:F) thin film prepared using spray pyrolysis technique acts as the TCO film and hence the bare electrode. The structural, morphological and elemental characterizations of the films were carried out using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray analysis (EDX) respectively. The diffraction peak positions in XRD confirmed the formation of highly crystalline ceria with cubic structure and FE-SEM images showed uniform adherent films with granular morphology. The band gaps of CeO 2 and TCO were found to be 3.2 eV and 2.6 eV respectively. Lipase enzyme was physisorbed on the surface of CeO 2 /TCO film to form the lipase/nano-CeO 2 /TCO bioelectrode. Sensing studies were carried out using cyclic voltammetry and amperometry, with lipase/nano-CeO 2 /TCO as working electrode and tributyrin as substrate. The mediator-free biosensor with nanointerface exhibited excellent linearity (0.33–1.98 mM) with a lowest detection limit of 2 μM with sharp response time of 5 s and a shelf life of about 6 weeks. -- Graphical abstract: Nanostructured cerium oxide thin films were deposited on transparent conducting oxide (TCO) substrate using spray pyrolysis technique. Fluorine doped cadmium oxide (CdO:F) thin film acts as the TCO film and hence the working electrode. Lipase enzyme was physisorbed on the surface of CeO 2 /TCO film and hence the lipase/nano-CeO 2 /TCO bioelectrode has been fabricated. Sensing studies were carried out using cyclic voltammetry and amperometry with tributyrin as substrate. The mediator-free biosensor with nanointerface exhibited excellent linearity (0.33–1.98 mM) with a lowest detection limit of 2 μM with sharp response time of 5 s and a shelf life of about 6

  9. Self-assembled films containing crude extract of avocado as a source of tyrosinase for monophenol detection

    International Nuclear Information System (INIS)

    Vieira, Nirton C.S.; Ferreira, Reginaldo A.; Cruz Rodrigues, Valquiria da; Guimarães, Francisco E.G.; Queiroz, Alvaro A.A. de

    2013-01-01

    This paper reports on the use of the crude extract of avocado (CEA) fruit (Persea americana) as a source of tyrosinase enzyme. CEA was immobilized via layer by layer (LbL) technique onto indium tin oxide (ITO) substrates and applied in the detection of monophenol using a potentiometric biosensor. Poly(propylene imine) dendrimer of generation 3 (PPI-G3) was used as a counter ion in the layer by layer process due to its highly porous structure and functional groups suitable for enzyme linkage. After the immobilization of the crude CEA as multilayered films, standard samples of monophenol were detected in the 0.25–4.00 mM linear range with approximately 28 mV mM −1 of sensitivity. This sensitivity is 14 times higher than the values found in the literature for a similar system. The results show that it is possible to obtain efficient and low-cost biosensors for monophenol detection using potentiometric transducers and alternative sources of enzymes without purification. - Highlights: • ITO films were functionalized with multilayers of PPI dendrimer and crude extract of avocado. • The films were applied as potentiometric biosensor for the detection of monophenol. • The proposed system presented an excellent sensitivity to monophenol (27 mV mM −1 )

  10. Decomposition of oxidezed lead and aluminium thin films on molybdenum substrates

    International Nuclear Information System (INIS)

    Makarovskij, N.A.

    1981-01-01

    The decomposition of oxidized solid phase lead and aluminium thin films on molybdenum substrates in the process of diffusion annealing in the 5x10 -5 mm Hg vacuum at temperatures from 280 to 320 deg C and from 500 to 560 deg C, respectively, is investigated. The conclusion is made that failure of oxidized lead and aluminium thin film coatings is carried out by the mechanism of volumetric self-diffusion. Experimentally established values of activation energies of the process of lead (Qsub(Mo)sup(Pb)=29 kcal/mol) and aluminium (Qsub(Mo)sup(Al)=35 kcal/mol) film failure are close to corresponding activation energies of lead and aluminium volumetric self-diffusion, which agrees with the conclusions made [ru

  11. Application of MM wave therapy in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Avakian, R.S. [Inst. of Radio Physics & Electronics, Ashtarack (Argentina); Gasparyan, L.V. [Republican Medical Centre Armenia, Yerevan (Argentina)

    1995-12-31

    The authors studied the effects of MM wave electromagnetic radiation influence on patients, affected by X-ray radiation during the reparation works after Chernobyl nuclear power plant exposure. They compared results of treatment of two groups of patients: (1) control group patients received only basis therapy; (2) testing group, 10 patients received basis therapy and MM wave influence. The authors used the wide band noise generator `Artsakh - 2` for local irradiation on the acupuncture points. Their data proved that low intensity MM waves have immunocorrective, antioxidant effects, and MM wave therapy is a perspective method for treatment of patients with radiological pathology.

  12. The addition of nanochitosan suspension as filler in carrageenan-tapioca biocomposite film

    Science.gov (United States)

    Rochima, Emma; Fiyanih, Elisah; Afrianto, Eddy; Subhan, Ujang; Praseptiangga, Danar; Panatarani, Camellia; Joni, I. Made

    2018-02-01

    This research aimed to investigate the effect of nanochitosan (CSNPs) suspension by beads milling method as filler in carrageenan-tapioca biocomposite film. In addition, the antibacterial activity of CSNPs as filler with two food pathogenic bacteria, Staphylococcus aureus and Escherichia coli and then influence of nano fillers for appearance of films were observed. The incorporation of CSNPs suspension with 0.5, 1, 1.5 and 2 (%v/v) in carrageenan-tapioca film exhibited antibacterial activity againts both bacteria. CSNPs had slightly higher antimicrobial activity against E. coli aureus compared to S. aureus at all concentrations due to different mechanisms. Therefore, the best antimicrobial activity was obtained from 1 wt%. Furthermore the best antimicrobial activity was characterized by means of the thickness and transparency. The result showed that the thickness of film was 0.059 mm and the transparency was 87.88. It was concluded that the incorporation of CSNPs suspension 1 wt% in carrageenan-tapioca composite film is suitable for developing active packaging.

  13. Aluminum-doped zinc oxide thin films grown on various substrates using facing target sputtering system

    Science.gov (United States)

    Kim, Hwa-Min; Lee, Chang Hyun; Shon, Sun Young; Kim, Bong Hwan

    2017-11-01

    Aluminum-doped zinc oxide (AZO) films were fabricated on various substrates, such as glass, polyethylene naphthalate (PEN), and polyethylene terephthalate (PET), at room temperature using a facing target sputtering (FTS) system with hetero ZnO and Al2O3 targets, and their electrical and optical properties were investigated. The AZO film on glass exhibited compressive stress while the films on the plastic substrates showed tensile stress. These stresses negatively affected the crystalline quality of the AZO films, and it is suggested that the poor crystalline quality of the films may be related to the neutral Al-based defect complexes formed in the films; these complexes act as neutral impurity scattering centers. AZO films with good optoelectronic properties could be formed on the glass and plastic substrates by the FTS technique using the hetero targets. The AZO films deposited on the glass, PEN, and PET substrates showed very low resistivities, of 5.0 × 10-4 Ω cm, 7.0 × 10-4 Ω cm, and 7.4 × 10-4 Ω cm, respectively. Further, the figure merit of the AZO film formed on the PEN substrate in the visible range (400-700 nm) was significantly higher than that of the AZO film on PET and similar to that of the AZO film on glass. Finally, the average transmittances of the films in the visible range (400-700 nm) were 83.16% (on glass), 76.3% (on PEN), and 78.16% (on PET).

  14. Tools to synthesize the learning of thin films

    International Nuclear Information System (INIS)

    Rojas, Roberto; Fuster, Gonzalo; Sluesarenko, Viktor

    2011-01-01

    After a review of textbooks written for undergraduate courses in physics, we have found that discussions on thin films are mostly incomplete. They consider the reflected and not the transmitted light for two instead of the four types of thin films. In this work, we complement the discussion in elementary textbooks, by analysing the phase differences required to match the conditions for constructive and destructive interference, in the reflected and transmitted light in four types of thin films. We consider thin films with varied sequences in the refractive index, which we identify as barriers, wells and stairs (up and down). Also, we use the conservation of energy in order to understand the complementary colour fringes observed in the reflected and transmitted light through thin films. We analyse systematically the phase changes by introducing a phase table and we synthesize the results in a circular diagram matching 16 physical situations of interference and their corresponding conditions on the film thickness. The phase table and the circular diagram are a pair of tools easily assimilated by students, and useful to organize, analyse and activate the knowledge about thin films.

  15. Dynamic film thickness between bubbles and wall in a narrow channel

    Science.gov (United States)

    Ito, Daisuke; Damsohn, Manuel; Prasser, Horst-Michael; Aritomi, Masanori

    2011-09-01

    The present paper describes a novel technique to characterize the behavior of the liquid film between gas bubbles and the wall in a narrow channel. The method is based on the electrical conductance. Two liquid film sensors are installed on both opposite walls in a narrow rectangular channel. The liquid film thickness underneath the gas bubbles is recorded by the first sensor, while the void fraction information is obtained by measuring the conductance between the pair of opposite sensors. Both measurements are taken on a large two-dimensional domain and with a high speed. This makes it possible to obtain the two-dimensional distribution of the dynamic liquid film between the bubbles and the wall. In this study, this method was applied to an air-water flow ranging from bubbly to churn regimes in the narrow channel with a gap width of 1.5 mm.

  16. Harmonic generation effect in high-Tc films

    International Nuclear Information System (INIS)

    Khare, Neeraj; Shrivastava, S.K.; Padmanabhan, V.P.N.; Khare, Sangeeta; Gupta, A.K.

    1997-01-01

    Harmonic generation in thick BPSCCO and thin YBCO films are reported. The application of an ac field (H ac > H c1 ) of frequency f causes the generation of odd harmonics of frequency (2n+1)f. The application of dc field in addition to the ac field causes the appearance of even harmonics also in the BPSCCO film. However, the appearance of even harmonics is not observed in YBCO film with high J c ∼ 1.6x10 6 A/cm 2 and appearance of second harmonic with small magnitude is observed in YBCO film with low J c ∼ 2x10 3 A/cm 2 . The variation of amplitudes of these harmonics are studied as a function of magnitude of ac and dc field and the results are explained in the framework of critical state model. A high-T c film magnetometer based on the measurement of the amplitude of second harmonic has been developed whose field sensitivity is ∼ 1.5x10 -8 T. (author)

  17. Effects of sodium hypochlorite on Agave tequilana Weber bagasse fibers used to elaborate cyto and biocompatible hydrogel films.

    Science.gov (United States)

    Tovar-Carrillo, Karla Lizette; Nakasone, Kazuki; Sugita, Satoshi; Tagaya, Motohiro; Kobayashi, Takaomi

    2014-09-01

    Waste bagasse of Agave tequilana-Weber fibers treated with sodium hydroxide was used to elaborate hydrogel films. The bagasse was offered in an alternative use for the preparation of hydrogel films by phase inversion method without crosslinking and further purification of cellulose. The effect on the properties of the obtained films was studied when the chemical treatment of the agave fibers was changed. It was found that the resultant hydrogels showed increment in tensile from 40 N/mm(2) to 56 N/mm(2) with the increase of sodium hypochlorite concentration from 1 to 10 vol.%, respectively. With regard to biocompatibility properties of the hydrogel films, platelet adhesion, clotting time and protein adsorption were investigated. Analysis of the morphology of adherent NIH3T3 fibroblast indicated that the projected cell area, aspect ratio and long axis gradually increased with the increment of sodium hypochlorite content in the agave treatment. It was presented that the chemical treatment affects cell adhesion and morphology and lignin content remains in the brown fibers. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Utilização de filmes plásticos e comestíveis na conservação pós-colheita de melão amarelo Utilization of PVC film and edible films to extend the postharvest conservation of yellow melons

    Directory of Open Access Journals (Sweden)

    Patrício F Batista

    2007-12-01

    Full Text Available Este trabalho teve como objetivo prolongar a vida pós-colheita de melões do tipo amarelo cv. AF-682, por meio da atmosfera modificada obtida com filme plástico de PVC e filmes comestíveis à base de cera de carnaúba (50% e fécula de mandioca (1, 2 e 3%. Para o revestimento dos frutos com embalagem plástica utilizou-se filme de PVC com 10 mm de espessura, aderente e esticável, colocado em camada única, na superfície de cada fruto. Após serem revestidos pelos filmes os frutos foram armazenados em temperatura ambiente de 29± 2ºC e 64±1% UR por 20 dias, sendo em intervalos de cinco dias submetidos às avaliações: massa individual, firmeza da polpa, teor de sólidos solúveis totais, acidez titulável e pH. Utilizou-se delineamento inteiramente casualizado com seis repetições em esquema fatorial 6x4, sendo 6 tratamentos de conservação e 4 períodos de armazenamento. Nenhum dos tratamentos avaliados é recomendável para aumentar a conservação pós-colheita de melão amarelo. Os frutos revestidos com fécula de mandioca a 3% e filme de PVC apresentaram processo iniciais característicos de fermentação e podridão a partir de 15 dias de armazenamento em temperatura ambiente.This work aimed to extend the postharvest life of yellow melons cv. AF-682 through modified atmosphere techniques obtained with PVC film and edible films such as carnauba wax (50% and cassava starch (1, 2 and 3%. Fruits were wrapped with one layer of adherent and stretchable PVC film with 10 mm width. After covering, fruits were stored at 29± 2ºC and 64±1% UR for 20 days. At a 5-day interval, fruits were evaluated for individual weight, pulp firmness, total soluble solids content, titratable acidity and pH. The trial was carried out in a complete randomized design, with six replications in a factorial scheme 6x4, with six treatments and four storage periods. The use of PVC film and edible films are not recommended to extend postharvest conservation of

  19. Effect of Ag film thickness on the optical and the electrical properties in CuAlO2/Ag/CuAlO2 multilayer films grown on glass substrates

    International Nuclear Information System (INIS)

    Oh, Dohyun; No, Young Soo; Kim, Su Youn; Cho, Woon Jo; Kwack, Kae Dal; Kim, Tae Whan

    2011-01-01

    Research highlights: The CuAlO 2 /Ag/CuAlO 2 multilayer films were grown on glass substrates using radio-frequency magnetron sputtering at room temperature. Effects of Ag film thickness on the optical and the electrical properties in CuAlO 2 /Ag/CuAlO 2 multilayer films grown on glass substrates were investigated. X-ray diffraction patterns showed that the phase of the CuAlO 2 layer was amorphous. Atomic force microscopy images showed that Ag films with a thickness of a few nanometers had island structures. The morphology Ag films with a thickness of 8 nm was uniform. The morphology of the Ag films inserted in the CuAlO 2 films significantly affected the optical transmittance and the resistivity of the CuAlO 2 films deposited on glass substrates. The maximum transmittance of the CuAlO 2 /Ag/CuAlO 2 multilayer films with a thickness of 8 nm was 89.16%. The resistivity of the CuAlO 2 /Ag/CuAlO 2 multilayer films with an Ag film thickness of 18 nm was as small as about 2.8 x 10 -5 Ω cm. The resistivity of the CuAlO 2 /Ag/CuAlO 2 multilayer films was decreased as a result of the thermal annealing treatment. These results indicate that CuAlO 2 /Ag/CuAlO 2 multilayer films grown on glass substrates hold promise for potential applications as TCO films in solar cells. - Abstract: Effects of Ag film thickness on the optical and the electrical properties in CuAlO 2 /Ag/CuAlO 2 multilayer films grown on glass substrates were investigated. Atomic force microscopy images showed that Ag films with a thickness of a few nanometers had island structures. X-ray diffraction patterns showed that the phase of the CuAlO 2 layer was amorphous. The resistivity of the 40 nm-CuAlO 2 /18 nm-Ag/40 nm-CuAlO 2 multilayer films was 2.8 x 10 -5 Ω cm, and the transmittance of the multilayer films with an Ag film thickness of 8 nm was approximately 89.16%. These results indicate that CuAlO 2 /Ag/CuAlO 2 multilayer films grown on glass substrates hold promise for potential applications as

  20. Visualization study of film drops produced by bubble bursting

    International Nuclear Information System (INIS)

    Ma Chao; Bo Hanliang

    2012-01-01

    The phenomenon that bubble bursting results in drops production is common in the steam generator of the nuclear power plant, and the fine drops generated by this way is one of the most important source of the drop entrainment in the vapor stream. The visualization experiment about the film drops produced by the bursting bubbles at a free water surface was studied using a high-speed video camera. The results show that the bubble cap breaks up in a single point, within the limits of bubble size in the experiment at present. The whole process can be distinguished into four successive stages: A primary inertial drainage, the bubble cap puncture at the foot or on the top, the film rolls-up and the liquid ring appearing with the hole expanding, and fine film drops emission under the effect of destabilization of a Rayleigh-Taylor type. The expression about the bubble radius and the film drops number is obtain by fitting the experiment data at the bubble radius range from 3-25 mm. The result trend agrees well with the previous work. (authors)

  1. Effect of Target Composition and Sputtering Deposition Parameters on the Functional Properties of Nitrogenized Ag-Permalloy Flexible Thin Films Deposited on Polymer Substrates

    Directory of Open Access Journals (Sweden)

    Waheed Khan

    2018-03-01

    Full Text Available We report the first results of functional properties of nitrogenized silver-permalloy thin films deposited on polyethylene terephthalic ester {PETE (C10H8O4n} flexible substrates by magnetron sputtering. These new soft magnetic thin films have magnetization that is comparable to pure Ni81Fe19 permalloy films. Two target compositions (Ni76Fe19Ag5 and Ni72Fe18Ag10 were used to study the effect of compositional variation and sputtering parameters, including nitrogen flow rate on the phase evolution and surface properties. Aggregate flow rate and total pressure of Ar+N2 mixture was 60 sccm and 0.55 Pa, respectively. The distance between target and the substrate was kept at 100 mm, while using sputtering power from 100–130 W. Average film deposition rate was confirmed at around 2.05 nm/min for argon atmosphere and was reduced to 1.8 nm/min in reactive nitrogen atmosphere. X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, vibrating sample magnetometer, and contact angle measurements were used to characterize the functional properties. Nano sized character of films was confirmed by XRD and SEM. It is found that the grain size was reduced by the formation of nitride phase, which in turns enhanced the magnetization and lowers the coercivity. Magnetic field coupling efficiency limit was determined from 1.6–2 GHz frequency limit. The results of comparable magnetic performance, lowest magnetic loss, and highest surface free energy, confirming that 15 sccm nitrogen flow rate at 115 W is optimal for producing Ag-doped permalloy flexible thin films having excellent magnetic field coupling efficiency.

  2. Study on optimization of YBCO thin film stack for compact NMR magnets

    International Nuclear Information System (INIS)

    Kim, S.B.; Kimoto, T.; Hahn, S.; Iwasa, Y.; Voccio, J.; Tomita, M.

    2013-01-01

    Highlights: ► Stacking methods for compact NMR magnet using YBCO thin films were tested. ► The stacking angles are 0°, 22.5° and 90° against the rolling direction. ► The best spatial field homogeneity was obtained in rotation angle of 22.5°. ► The maximum trapped magnetic fields of 0.4 T was obtained at 77.4 K. ► The maximum trapped magnetic fields of 0.95 T was obtained at 21 K. -- Abstract: A compact high temperature superconducting (HTS) magnet, which consists of a stack of 500 HTS thin film annuli, was constructed and tested. Each thin film annulus, manufactured by the AMSC using the Rolling Assisted Bi-axially Textured Substrate (RABiTS) method, has a square cross-section of 40 mm × 40 mm with a thickness of 80 m. It has a 25-mm center hole created by machining. This paper reports a study on the anisotropic J c issue due to the rolling procedure of the Ni substrate direction and its impact on field homogeneity. Also, three different stacking methods with rotation angles of 22.5°, 90°, and 0° against the rolling direction have been tested to study their impacts on strength, spatial homogeneity, and temporal stability of trapped fields. Finally, the 500-annulus magnet was tested at 21 K under a cryogen-free environment using a GM cryocooler. The spatial field homogeneity and temporal stability were measured at 21 K and compared with those obtained in a bath of liquid nitrogen at 77 K

  3. Improving Performance of CIGS Solar Cells by Annealing ITO Thin Films Electrodes

    Directory of Open Access Journals (Sweden)

    Chuan Lung Chuang

    2015-01-01

    Full Text Available Indium tin oxide (ITO thin films were grown on glass substrates by direct current (DC reactive magnetron sputtering at room temperature. Annealing at the optimal temperature can considerably improve the composition, structure, optical properties, and electrical properties of the ITO film. An ITO sample with a favorable crystalline structure was obtained by annealing in fixed oxygen/argon ratio of 0.03 at 400°C for 30 min. The carrier concentration, mobility, resistivity, band gap, transmission in the visible-light region, and transmission in the near-IR regions of the ITO sample were -1.6E+20 cm−3, 2.7E+01 cm2/Vs, 1.4E-03 Ohm-cm, 3.2 eV, 89.1%, and 94.7%, respectively. Thus, annealing improved the average transmissions (400–1200 nm of the ITO film by 16.36%. Moreover, annealing a copper-indium-gallium-diselenide (CIGS solar cell at 400°C for 30 min in air improved its efficiency by 18.75%. The characteristics of annealing ITO films importantly affect the structural, morphological, electrical, and optical properties of ITO films that are used in solar cells.

  4. Zinc oxide-potassium ferricyanide composite thin film matrix for biosensing applications

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Shibu [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Arya, Sunil K. [Department of Science and Technology Centre on Biomolecular Electronics, National Physical Laboratory, New Delhi 110012 (India); Singh, S.P. [Department of Engineering Science and Materials, University of Puerto Rico, Mayaguez, PR 00680 (United States); Sreenivas, K. [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Malhotra, B.D. [Department of Science and Technology Centre on Biomolecular Electronics, National Physical Laboratory, New Delhi 110012 (India); Gupta, Vinay, E-mail: vgupta@physics.du.ac.in [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India)

    2009-10-27

    Thin film of zinc oxide-potassium ferricyanide (ZnO-KFCN) composite has been deposited on indium tin oxide (ITO) coated corning glass using pulsed laser deposition (PLD). The composite thin film electrode has been exploited for amperometric biosensing in a mediator-free electrolyte. The composite matrix has the advantages of high iso-electric point of ZnO along with enhanced electron communication due to the presence of a redox species in the matrix itself. Glucose oxidase (GOx) has been chosen as the model enzyme for studying the application of the developed matrix to biosensing. The sensing response of the bio-electrode, GOx/ZnO-KFCN/ITO/glass, towards glucose was studied using cylic voltammetry (CV) and photometric assay. The bio-electrode exhibits good linearity from 2.78 mM to 11.11 mM glucose concentration. The low value of Michaelis-Menten constant (1.69 mM) indicates an enhanced affinity of the immobilized enzyme towards its substrate. A quassireversible system is obtained with the composite matrix. The results confirm promising application of the ZnO-KFCN composite matrix for amperometric biosensing applications in a mediator-less electrolyte that could lead to the realization of an integrated lab-on-chip device.

  5. Zinc oxide-potassium ferricyanide composite thin film matrix for biosensing applications

    International Nuclear Information System (INIS)

    Saha, Shibu; Arya, Sunil K.; Singh, S.P.; Sreenivas, K.; Malhotra, B.D.; Gupta, Vinay

    2009-01-01

    Thin film of zinc oxide-potassium ferricyanide (ZnO-KFCN) composite has been deposited on indium tin oxide (ITO) coated corning glass using pulsed laser deposition (PLD). The composite thin film electrode has been exploited for amperometric biosensing in a mediator-free electrolyte. The composite matrix has the advantages of high iso-electric point of ZnO along with enhanced electron communication due to the presence of a redox species in the matrix itself. Glucose oxidase (GOx) has been chosen as the model enzyme for studying the application of the developed matrix to biosensing. The sensing response of the bio-electrode, GOx/ZnO-KFCN/ITO/glass, towards glucose was studied using cylic voltammetry (CV) and photometric assay. The bio-electrode exhibits good linearity from 2.78 mM to 11.11 mM glucose concentration. The low value of Michaelis-Menten constant (1.69 mM) indicates an enhanced affinity of the immobilized enzyme towards its substrate. A quassireversible system is obtained with the composite matrix. The results confirm promising application of the ZnO-KFCN composite matrix for amperometric biosensing applications in a mediator-less electrolyte that could lead to the realization of an integrated lab-on-chip device.

  6. Preparation of sup 125 I-creatine phosphokinase-MM

    Energy Technology Data Exchange (ETDEWEB)

    Jingxian, Su; Jingmin, Ma [Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

    1988-09-01

    {sup 125}I-creatine phosphokinase-MM ({sup 125}I-CPK-MM) was prepared by {sup 125}I-labelled Bolton-Hunter reagent (HPNS). Iodinating conditions of HPNS and its conjugation to protein were studied. {sup 125}I-CPK-MM with immune activity was obtained and used to establish the {sup 125}I-CPK-MM radioimmunoassay method by the General Hospital of PLA. {sup 125}I-CPK-MM in PBS-G solution containing 0.015 mol/l ethyl mercaptan at 4-10 deg C can be used for one month.

  7. Mechanical properties of bioplastics cassava starch film with Zinc Oxide nanofiller as reinforcement

    Science.gov (United States)

    Harunsyah; Yunus, M.; Fauzan, Reza

    2017-06-01

    This study focuses on investigating the influence of zinc oxide nanofiller on the mechanical properties of bioplastic cassava starch films. Bioplastic cassava starch film-based zinc oxide reinforced composite biopolymeric films were prepared by casting technique. The content of zinc oxide in the bioplastic films was varied from 0.2%, 0.4%, 0.6%, 0.8% and 1.0% (w/w) by weight of starch. Surface morphologies of the composites bioplastic films were examined by scanning electron microscope (SEM).The result showed that the Tensile strength (TS) was improved significantly with the additional of zinc oxide but the elongation at break (EB %) of the composites was decreased. The maximum tensile strength obtained was 22.30 kgf / mm on the additional of zinc oxide by 0.6% and plastilizer by 25%. Based on data of FTIR, the produced film plastic did not change the group function and it can be concluded that theinteraction in film plastic produced was only a physical interaction. Biodegradable plastic film based on cassava starch-zinc oxide and plasticizer glycerol showed that interesting mechanical properties being transparent, clear, homogeneous, flexible, and easily handled.

  8. The effect of bubble acceleration on the liquid film thickness in micro tubes

    Energy Technology Data Exchange (ETDEWEB)

    Han, Youngbae, E-mail: bhan@feslab.t.u-tokyo.ac.j [Department of Mechanical Engineering, University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-8656 (Japan); Shikazono, Naoki, E-mail: shika@feslab.t.u-tokyo.ac.j [Department of Mechanical Engineering, University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2010-08-15

    Liquid film thickness is an important parameter for predicting boiling heat transfer in micro tubes. In the previous study (), liquid film thickness under the steady condition was investigated and an empirical correlation for the initial liquid film thickness based on capillary number, Reynolds number and Weber number was proposed. However, under flow boiling conditions, bubble velocity is not constant but accelerated due to evaporation. It is necessary to consider this bubble acceleration effect on the liquid film thickness, since it affects viscous, surface tension and inertia forces in the momentum equation. In addition, viscous boundary layer develops, and it may also affect the liquid film thickness. In the present study, the effect of bubble acceleration is investigated. Laser focus displacement meter is used to measure the liquid film thickness. Ethanol, water and FC-40 are used as working fluids. Circular tubes with three different inner diameters, D = 0.5, 0.7 and 1.0 mm, are used. The increase of liquid film thickness with capillary number is restricted by the bubble acceleration. Finally, an empirical correlation is proposed for the liquid film thickness of accelerated flows in terms of capillary number and Bond number based on the bubble acceleration.

  9. The effect of bubble acceleration on the liquid film thickness in micro tubes

    International Nuclear Information System (INIS)

    Han, Youngbae; Shikazono, Naoki

    2010-01-01

    Liquid film thickness is an important parameter for predicting boiling heat transfer in micro tubes. In the previous study (), liquid film thickness under the steady condition was investigated and an empirical correlation for the initial liquid film thickness based on capillary number, Reynolds number and Weber number was proposed. However, under flow boiling conditions, bubble velocity is not constant but accelerated due to evaporation. It is necessary to consider this bubble acceleration effect on the liquid film thickness, since it affects viscous, surface tension and inertia forces in the momentum equation. In addition, viscous boundary layer develops, and it may also affect the liquid film thickness. In the present study, the effect of bubble acceleration is investigated. Laser focus displacement meter is used to measure the liquid film thickness. Ethanol, water and FC-40 are used as working fluids. Circular tubes with three different inner diameters, D = 0.5, 0.7 and 1.0 mm, are used. The increase of liquid film thickness with capillary number is restricted by the bubble acceleration. Finally, an empirical correlation is proposed for the liquid film thickness of accelerated flows in terms of capillary number and Bond number based on the bubble acceleration.

  10. Solvent Hold Tank Sample Results for MCU-16-991-992-993: July 2016 Monthly sample and MCU-16-1033-1034-1035: July 2016 Superwashed Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-11-25

    SRNL received one set of SHT samples (MCU-16-991, MCU-16-992 and MCU-16-993), pulled on 07/13/2016 and another set of SHT samples (MCU-16-1033, MCU-16-1034, and MCU-16-1035) that were pulled on 07/24/2016 after the solvent was superwashed with 300 mM sodium hydroxide for analysis. Samples MCU-16-991, MCU-16-992, and MCU-16-993 were combined into one sample (MCU-16-991-992-993) and samples MCU-16-1033, MCU-16-1034, and MCU-16-1035 were combined into one sample (MCU-16-1033-1034-1035). Of the two composite samples MCU-16-1033-1034-1035 represents the current chemical state of the solvent at MCU. All analytical conclusions are based on the chemical analysis of MCU-16-1033-1034-1035. There were no chemical differences between MCU-16- 991-992-993 and superwashed MCU-16-1033-1034-1035.

  11. Quantifying oxygen in paper-based cell cultures with luminescent thin film sensors.

    Science.gov (United States)

    Boyce, Matthew W; Kenney, Rachael M; Truong, Andrew S; Lockett, Matthew R

    2016-04-01

    Paper-based scaffolds are an attractive material for generating 3D tissue-like cultures because paper is readily available and does not require specialized equipment to pattern, cut, or use. By controlling the exchange of fresh culture medium with the paper-based scaffolds, we can engineer diffusion-dominated environments similar to those found in spheroids or solid tumors. Oxygen tension directly regulates cellular phenotype and invasiveness through hypoxia-inducible transcription factors and also has chemotactic properties. To date, gradients of oxygen generated in the paper-based cultures have relied on cellular response-based readouts. In this work, we prepared a luminescent thin film capable of quantifying oxygen tensions in apposed cell-containing paper-based scaffolds. The oxygen sensors, which are polystyrene films containing a Pd(II) tetrakis(pentafluorophenyl)porphyrin dye, are photostable, stable in culture conditions, and not cytotoxic. They have a linear response for oxygen tensions ranging from 0 to 160 mmHg O2, and a Stern-Volmer constant (K sv) of 0.239 ± 0.003 mmHg O2 (-1). We used these oxygen-sensing films to measure the spatial and temporal changes in oxygen tension for paper-based cultures containing a breast cancer line that was engineered to constitutively express a fluorescent protein. By acquiring images of the oxygen-sensing film and the fluorescently labeled cells, we were able to approximate the oxygen consumption rates of the cells in our cultures.

  12. Synthesis of diamondlike carbon films with superlow friction and wear properties

    Energy Technology Data Exchange (ETDEWEB)

    Erdemir, A. [Energy Technology Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Eryilmaz, O. L. [Energy Technology Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Fenske, G. [Energy Technology Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2000-07-01

    In this study, we introduce a new diamondlike carbon (DLC) film providing a friction coefficient of 0.001 and wear rates of 10{sup -9}-10{sup -10} mm{sup 3}/N m in inert-gas environments (e.g., dry nitrogen and argon). The film was grown on steel and sapphire substrates in a plasma enhanced chemical vapor deposition system that uses a hydrogen-rich plasma. Employing a combination of surface and structure analytical techniques, we explored the structural chemistry of the resultant DLC films and correlated these findings with the friction and wear mechanisms of the films. The results of tribological tests under a 10 N load (creating initial peak Hertz pressures of 1 and 2.2 GPa on steel and sapphire test pairs, respectively) and at 0.2 to 0.5 m/s sliding velocities indicated that a close correlation exists between the friction and wear coefficients of DLC films and the source gas chemistry. Specifically, films grown in source gases with higher hydrogen-to-carbon ratios had the lowest friction coefficients and the highest wear resistance. The lowest friction coefficient (0.001) was achieved with a film on sapphire substrates produced in a gas discharge plasma consisting of 25% methane and 75% hydrogen. (c) 2000 American Vacuum Society.

  13. Nanometric hybrid films of xanthan and magnetite

    International Nuclear Information System (INIS)

    Pereira, Edla M.A.; Silva, Anielle M.; Petri, Denise F.S.

    2011-01-01

    Magnetite nanoparticles (NMM) were synthesized by co-characterized by means of X-ray diffraction, infrared spectroscopy and potentiometric titration. Xanthan thin films and NMM were deposited alternately onto Si wafers. The attachment of first xanthan layer onto Si wafer was obtained in the presence of Ca 2+ 1 mM and at pH 10. Under these conditions calcium ions interact electrostatically with both silanol groups and xanthan carboxylate groups, yielding stable xanthan (1.5 ± 0.5) nm thick films. The deposition of NMM was forced by applying a magnetic field set under the sample. The following bilayers were formed by 'layer-by-layer' electrostatic process and magnetic field action. The bilayers formation was monitored by the variation in the ellipsometric angles values, Δ e ψ, and atomic force microscopy. (author)

  14. Verifying the nuclear-test ban. CTBTO: For a safer and more secure world [videorecording

    International Nuclear Information System (INIS)

    1999-01-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) was opened for signature in September 1996. In March 1997, the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization started work in Vienna, Austria. This film depicts the Commission's activities in establishing the Treaty's verification regime to monitor adherence to the global ban on nuclear explosions. It presents the challenging work at some of the global monitoring facilities, and at the International Data Centre in Vienna, where the data generated by the facilities are received, processed and analysed

  15. Calibration of flavour tagging with B+ -> J/psi(mm)K+ and B0 ->J/psi(mm)K* control channels at LHCb

    CERN Document Server

    Calvi, M; Leroy, O; Musy, M; Poss, S; Vecchi, S

    2009-01-01

    B+ -> J/psi(mm)K+ and B0 ->J/psi(mm)K* are suitable control channels for the calibration of flavour tagging for CP measurements in Bs ->J/psi(mm) phi and B0 ->J/psi(mm)KS channels; in the first case if opposite side tagging only is considered. In this note we describe the calibration of the probability of mistag performed with B+ ->J/psi(mm)K+ events and the measurement of the mistag performed with B0 ->J/psi(mm)K* events in a fit to flavour oscillation as a function of proper time. Models are developed to extract this information from selected events taking into account different background components. An expected statistical sensitivity on the average opposite side mistag rate sigma(wOS)/ wOS = 0.3 % is obtained for B0 ->J/psi(mm)K* events, in 2 fb-1 of data.

  16. Design and development of an in-line sputtering system and process development of thin film multilayer neutron supermirrors

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, A.; Sampathkumar, R.; Kumar, Ajaya; Bhattacharyya, D.; Sahoo, N. K. [Atomic and Molecular Physics Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Lagoo, K. D.; Veerapur, R. D.; Padmanabhan, M.; Puri, R. K. [Division of Remote Handling and Robotics, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Bhattacharya, Debarati; Singh, Surendra; Basu, S. [Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2014-12-15

    Neutron supermirrors and supermirror polarizers are thin film multilayer based devices which are used for reflecting and polarizing neutrons in various neutron based experiments. In the present communication, the in-house development of a 9 m long in-line dc sputtering system has been described which is suitable for deposition of neutron supermirrors on large size (1500 mm × 150 mm) substrates and in large numbers. The optimisation process of deposition of Co and Ti thin film, Co/Ti periodic multilayers, and a-periodic supermirrors have also been described. The system has been used to deposit thin film multilayer supermirror polarizers which show high reflectivity up to a reasonably large critical wavevector transfer of ∼0.06 Å{sup −1} (corresponding to m = 2.5, i.e., 2.5 times critical wavevector transfer of natural Ni). The computer code for designing these supermirrors has also been developed in-house.

  17. A comparable study of clinical and optical outcomes after 1.8, 2.0 mm microcoaxial and 3.0 mm coaxial cataract surgery.

    Science.gov (United States)

    Yu, Yi-Bo; Zhu, Ya-Nan; Wang, Wei; Zhang, Yi-Dong; Yu, Yin-Hui; Yao, Ke

    2016-01-01

    To evaluate the clinical and optical outcomes after clear corneal incision cataract surgery (CICS) with three different incision sizes (1.8, 2.0 and 3.0 mm). Eyes of 150 patients with age-related cataract scheduled for coaxial cataract surgery were randomized to three groups: 1.8, 2.0, or 3.0 mm CICS. Intraoperative data and postoperative outcomes including surgically induced astigmatism (SIA), the corneal incision thickness, wavefront aberrations and modulation transfer function (MTF) of cornea were obtained. There were no significant differences among the three groups in demographic characteristics and intraoperative outcome. The 1.8 and 2.0 mm microincisions showed more satisfactory clinical outcomes than the 3.0 mm incision. The 1.8 mm incision showed significantly less SIA than the 2.0 mm incision until postoperative 1mo (P0.05). Converting from 3.0 mm CICS to 1.8 or 2.0 mm CICS result in better clinical and optical outcomes. However, when incision is 1.8 mm, the benefits from further reduction in size compared with 2.0 mm are limited. The necessity to reduce the incision size is to be deliberated.

  18. Spectral and Energy Efficiencies in mmWave Cellular Networks for Optimal Utilization

    Directory of Open Access Journals (Sweden)

    Abdulbaset M. Hamed

    2018-01-01

    Full Text Available Millimeter wave (mmWave spectrum has been proposed for use in commercial cellular networks to relieve the already severely congested microwave spectrum. Thus, the design of an efficient mmWave cellular network has gained considerable importance and has to take into account regulations imposed by government agencies with regard to global warming and sustainable development. In this paper, a dense mmWave hexagonal cellular network with each cell consisting of a number of smaller cells with their own Base Stations (BSs is presented as a solution to meet the increasing demand for a variety of high data rate services and growing number of users of cellular networks. Since spectrum and power are critical resources in the design of such a network, a framework is presented that addresses efficient utilization of these resources in mmWave cellular networks in the 28 and 73 GHz bands. These bands are already an integral part of well-known standards such as IEEE 802.15.3c, IEEE 802.11ad, and IEEE 802.16.1. In the analysis, a well-known accurate mmWave channel model for Line of Sight (LOS and Non-Line of Sight (NLOS links is used. The cellular network is analyzed in terms of spectral efficiency, bit/s, energy efficiency, bit/J, area spectral efficiency, bit/s/m2, area energy efficiency, bit/J/m2, and network latency, s/bit. These efficiency metrics are illustrated, using Monte Carlo simulation, as a function of Signal-to-Noise Ratio (SNR, channel model parameters, user distance from BS, and BS transmission power. The efficiency metrics for optimum deployment of cellular networks in 28 and 73 GHz bands are identified. Results show that 73 GHz band achieves better spectrum efficiency and the 28 GHz band is superior in terms of energy efficiency. It is observed that while the latter band is expedient for indoor networks, the former band is appropriate for outdoor networks.

  19. Preparation and characterization of sponge film made from feathers.

    Science.gov (United States)

    Zhuang, Yuan; Wu, Xiaoqian; Cao, Zhangjun; Zhao, Xiaoxiang; Zhou, Meihua; Gao, Pin

    2013-12-01

    Feather wastes generated from poultry farms will pose a problem for disposal, but they are sustainable resources of keratin. Reduction is one of the commonly used methods to obtain soluble keratin from feather. However, the residues generated during feather reduction reaction were rarely investigated. In this study, the residues were transformed into a porous and flexible sponge film by freeze-drying without pretreatment or addition of cross-linking agents. Glycerol was used to alter the physical and chemical characteristics of the sponge film. The film was characterized with a fiber strong stretch instrument, a Fourier transform infrared spectrophotometer, scanning electron microscopy, an elemental analyzer, a differential scanning calorimeter and an automatic air permeability apparatus. Tensile strength and melting point of the sponge film with the optimum glycerol content were 6.2 MPa and 170°C respectively. Due to air permeability of 368 mm/s, the film can potentially be used in medicine, biology, textile, environmental technology, and so on. It is ecologically friendly and will produce additional benefits from the renewable materials. The film was utilized as adsorbents to remove Cr(VI) from aqueous solutions and as a filtering material for air pollution. Its maximum Cr(VI) uptake capacity was about 148.8 mg/g and the removal rate of PM10 was 98.3%. © 2013.

  20. Attractiveness of MM-X traps baited with human or synthetic odor to mosquitoes (Diptera: Culicidae) in The Gambia

    NARCIS (Netherlands)

    Qiu, Y.T.; Smallegange, R.C.; Braak, ter C.J.F.; Spitzen, J.; Loon, van J.J.A.; Jawara, M.; Milligan, P.; Galimard, A.M.S.; Beek, van T.A.; Knols, B.G.J.; Takken, W.

    2007-01-01

    Chemical cues play an important role in the host-seeking behavior of blood-feeding mosquitoes (Diptera: Culicidae). A field study was carried out in The Gambia to investigate the effects of human odor or synthetic odor blends on the attraction of mosquitoes. MM-X traps baited with 16 odor blends to

  1. Electromagnetic shielding effectiveness of a thin silver layer deposited onto PET film via atmospheric pressure plasma reduction

    Science.gov (United States)

    Oh, Hyo-Jun; Dao, Van-Duong; Choi, Ho-Suk

    2018-03-01

    This study presents the first use of a plasma reduction reaction under atmospheric pressure to fabricate a thin silver layer on polyethylene terephthalate (PET) film without the use of toxic chemicals, high voltages, or an expensive vacuum apparatus. The developed film is applied to electromagnetic interference (EMI) shielding. After repeatedly depositing a silver layer through a plasma reduction reaction on PET, we can successfully fabricate a uniformly deposited thin silver layer. It was found that both the particle size and film thickness of thin silver layers fabricated at different AgNO3 concentrations increase with an increase in the concentration of AgNO3. However, the roughness of the thin silver layer decreases when increasing the concentration of AgNO3 from 100 to 500 mM, and the roughness increases with a further increase in the concentration of AgNO3. The EMI shielding effectiveness (SE) of the film is measured in the frequency range of 0.045 to 1 GHz. As a result of optimizing the electrical conductivity by measuring sheet resistance of the thin silver layer, the film fabricated from 500 mM AgNO3 exhibits the highest EMI SE among all fabricated films. The maximum values of the EMI SE are 60.490 dB at 0.1 GHz and 54.721 dB at 1.0 GHz with minimum sheet resistance of 0.244 Ω/□. Given that the proposed strategy is simple and effective, it is promising for fabricating various low-cost metal films with high EMI SE.

  2. Tungsten oxide thin films grown by thermal evaporation with high resistance to leaching

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Diogo S. [Universidade Federal de Pelotas (UFPel), RS (Brazil). Centro de Ciencias Quimicas, Farmaceuticas e de Alimentos; Pazinato, Julia C.O.; Freitas, Mauricio A. de; Radtke, Claudio; Garcia, Irene T.S., E-mail: irene@iq.ufrgs.br [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Instituto de Quimica; Dorneles, Lucio S. [Universidade Federal de Santa Maria (UFSM), RS (Brazil). Centro de Ciencias Naturais e Exatas

    2014-05-15

    Tungsten oxides show different stoichiometries, crystal lattices and morphologies. These characteristics are important mainly when they are used as photocatalysts. In this work tungsten oxide thin films were obtained by thermal evaporation on (100) silicon substrates covered with gold and heated at 350 and 600 °C, with different deposition times. The stoichiometry of the films, morphology, crystal structure and resistance to leaching were characterized through X-ray photoelectron spectroscopy, micro-Raman spectroscopy, scanning and transmission electron microscopy, X-ray diffractometry, Rutherford backscattering spectrometry and O{sup 16} (α,α')O{sup 16} resonant nuclear reaction. Films obtained at higher temperatures show well-defined spherical nanometric structure; they are composed of WO{sub 3.1} and the presence of hydrated tungsten oxide was also observed. The major crystal structure observed is the hexagonal. Thin films obtained through thermal evaporation present resistance to leaching in aqueous media and excellent performance as photocatalysts, evaluated through the degradation of the methyl orange dye. (author)

  3. Thin films and nanomaterials

    International Nuclear Information System (INIS)

    Jayakumar, S.; Kannan, M.D.; Prasanna, S.

    2012-01-01

    The objective of this book is to disseminate the most recent research in Thin Films, Nanomaterials, Corrosion and Metallurgy presented at the International Conference on Advanced Materials (ICAM 2011) held in PSG College of Technology, Coimbatore, India during 12-16 December 2011. The book is a compilation of 113 chapters written by active researchers providing information and critical insights into the recent advancements that have taken place. Important new applications are possible today in the fields of microelectronics, opto-electronics, metallurgy and energy by the application of thin films on solid surfaces. Recent progress in high vacuum technology and new materials has a remarkable effect in thin film quality and cost. This has led to the development of new single or multi-layered thin film devices with diverse applications in a multitude of production areas, such as optics, thermal barrier coatings and wear protections, enhancing service life of tools and to protect materials against thermal and atmospheric influence. On the other hand, thin film process techniques and research are strongly related to the basic research activities in nano technology, an increasingly important field with countless opportunities for applications due to the emergence of new properties at the nanoscale level. Materials and structures that are designed and fabricated at the nano scale level, offer the potential to produce new devices and processes that may enhance efficiencies and reduce costs in many areas, as photovoltaic systems, hydrogen storage, fuel cells and solar thermal systems. In the book, the contributed papers are classified under two sections i) thin films and ii) nanomaterials. The thin film section includes single or multi layer conducting, insulating or semiconducting films synthesized by a wide variety of physical or chemical techniques and characterized or analyzed for different applications. The nanomaterials section deals with novel or exciting materials

  4. XPS and TEM study of W-DLC/DLC double-layered film

    International Nuclear Information System (INIS)

    Takeno, Takanori; Komiyama, Takao; Miki, Hiroyuki; Takagi, Toshiyuki; Aoyama, Takashi

    2009-01-01

    A double-layered film of tungsten-containing diamond-like carbon (W-DLC) and DLC, (W-DLC)/DLC, was investigated. A film of 1.6 μm in thickness was deposited onto silicon substrate. The investigate double-layered coating was deposited by using the combination of PECVD and co-sputtering of tungsten metal target. Structure, interface and chemical bonding state of the investigated film were analyzed by Transmission electron microscope (TEM) and X-ray photoelectron spectroscopy (XPS). From the results of the analyses, the structure of double-layered film is that amorphous phase of carbon is continued from DLC to W-DLC and tungsten metal clusters are dispersed in W-DLC layer.

  5. InGaAs-OI Substrate Fabrication on a 300 mm Wafer

    Directory of Open Access Journals (Sweden)

    Sebastien Sollier

    2016-09-01

    Full Text Available In this work, we demonstrate for the first time a 300-mm indium–gallium–arsenic (InGaAs wafer on insulator (InGaAs-OI substrates by splitting in an InP sacrificial layer. A 30-nm-thick InGaAs layer was successfully transferred using low temperature direct wafer bonding (DWB and Smart CutTM technology. Three key process steps of the integration were therefore specifically developed and optimized. The first one was the epitaxial growing process, designed to reduce the surface roughness of the InGaAs film. Second, direct wafer bonding conditions were investigated and optimized to achieve non-defective bonding up to 600 °C. Finally, we adapted the splitting condition to detach the InGaAs layer according to epitaxial stack specifications. The paper presents the overall process flow that achieved InGaAs-OI, the required optimization, and the associated characterizations, namely atomic force microscopy (AFM, scanning acoustic microscopy (SAM, and HR-XRD, to insure the crystalline quality of the post transferred layer.

  6. Electrical characterization of MIS devices using PECVD SiN{sub x}:H films for application of silicon solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jin-Su; Cho, Jun-Sik; Park, Joo-Hyung; Ahn, Seung-Kyu; Shin, Kee-Shik; Yoon, Kyung-Hoon [Korea Institute of Energy Research, Daejeon (Korea, Republic of); Yi, Jun-Sin [Sungkyunkwan University, Suwon (Korea, Republic of)

    2012-07-15

    The surface passivation of crystalline silicon solar cells using plasma enhanced chemical vapor deposition (PECVD), hydrogenated, silicon-nitride (SiN{sub x}:H) thin films has become significant due to a low-temperature, low-cost and very effective defect passivation process. Also, a good quality antireflection coating can be formed. In this work, SiN{sub x}:H thin films were deposited by varying the gas ratio R (=NH{sub 3}/SiH{sub 4}+NH{sub 3}) and were annealed by rapid thermal processing (RTP). Metal-insulator- semiconductor (MIS) devices were fabricated using SiN{sub x}:H thin films as insulator layers and they were analyzed in the temperature range of 100 - 400 K by using capacitance-voltage (C-V) and current-voltage (I-V) measurements. The annealed SiN{sub x}:H thin films were evaluated by using the electrical properties at different temperature to determine the effect of surface passivation. We achieved an energy conversion efficiency of 18.1% under one-sun standard testing conditions for large-area (156 mm x 156 mm) crystalline-silicon solar cells.

  7. SU-E-T-121: Dosimetric Characterization of Gafchromic Film EBT3 Using Vidar DosimetryPro Advantage RED and EPSON Expression 10000XL Scanners

    International Nuclear Information System (INIS)

    Medina, L; Adrada, A; Filipuzzi, M; Garrigo, E; Venencia, C

    2014-01-01

    Purpose: The purpose of this paper is to characterize EBT3 using two types of scanner, analyzing the factors of influence of each dosimetry system. Methods: The film used in this study was GAFCHROMIC EBT3, the films were exposed at a dose range between 0Gy a 9Gy in a solid water phantom, SSD=100cm, 5cm depth and perpendicularly to the 6MV photon beam generated by a Novalis TX linear accelerator equipped with an HDMLC. A Farmer type ion chamber TN30013 (PTW) was used to determine the dose delivered to the film. The films were digitized with a scanner EPSON expression 10000XL and the VIDAR DosimetryPro Adventage RED. Software RIT113v6.1 was used for construction of the calibration curve and analysis. The film characteristics investigated were: response at different dose levels, sensitivity to orientation and side and resolution through the results of the spatial response function by analyzing a step pattern. Additionally, 20 IMRT treatment fields were measured with both scanner and compared with calculated dose using gamma index analysis (3%-3mm). Results: The OD obtained for dose level 2Gy in the orientation portrait of the film on the scanner EPSON is (0,222±0,19) and for Vidar RED (0,252±0,10) and landscape is for EPSON (0,211±0,25) and for Vidar RED (0,250±0,11) . The orientation dependence with respect to film side is about 0,09% for EPSON and about 0.03% for VIDAR. The spatial response function increase in response to the Gaussian function FWHM EPSON scanner (0.18mm) compared with VIDAR scanner function (less than 0.06mm) was observed. We analyzed 20 total plan dose distributions the number of pixels with gamma>1 (3%-3mm) was 0.7%±1.2 [0.1%; 2.82%] for EBT3-VIDAR y 2%±2.9 [0.2%; 3.5%] for EBT3-EPSON. Conclusion: VIDAR scanner shows better sensitivity. EBT3 film shows a different response between portrait and landscape orientation. Step pattern is better reproduce by VIDAR scanner

  8. SU-E-T-121: Dosimetric Characterization of Gafchromic Film EBT3 Using Vidar DosimetryPro Advantage RED and EPSON Expression 10000XL Scanners

    Energy Technology Data Exchange (ETDEWEB)

    Medina, L; Adrada, A; Filipuzzi, M; Garrigo, E; Venencia, C [Instituto Privado de Radioterapia - Fundacion Marie Curie, Cordoba (Argentina)

    2014-06-01

    Purpose: The purpose of this paper is to characterize EBT3 using two types of scanner, analyzing the factors of influence of each dosimetry system. Methods: The film used in this study was GAFCHROMIC EBT3, the films were exposed at a dose range between 0Gy a 9Gy in a solid water phantom, SSD=100cm, 5cm depth and perpendicularly to the 6MV photon beam generated by a Novalis TX linear accelerator equipped with an HDMLC. A Farmer type ion chamber TN30013 (PTW) was used to determine the dose delivered to the film. The films were digitized with a scanner EPSON expression 10000XL and the VIDAR DosimetryPro Adventage RED. Software RIT113v6.1 was used for construction of the calibration curve and analysis. The film characteristics investigated were: response at different dose levels, sensitivity to orientation and side and resolution through the results of the spatial response function by analyzing a step pattern. Additionally, 20 IMRT treatment fields were measured with both scanner and compared with calculated dose using gamma index analysis (3%-3mm). Results: The OD obtained for dose level 2Gy in the orientation portrait of the film on the scanner EPSON is (0,222±0,19) and for Vidar RED (0,252±0,10) and landscape is for EPSON (0,211±0,25) and for Vidar RED (0,250±0,11) . The orientation dependence with respect to film side is about 0,09% for EPSON and about 0.03% for VIDAR. The spatial response function increase in response to the Gaussian function FWHM EPSON scanner (0.18mm) compared with VIDAR scanner function (less than 0.06mm) was observed. We analyzed 20 total plan dose distributions the number of pixels with gamma>1 (3%-3mm) was 0.7%±1.2 [0.1%; 2.82%] for EBT3-VIDAR y 2%±2.9 [0.2%; 3.5%] for EBT3-EPSON. Conclusion: VIDAR scanner shows better sensitivity. EBT3 film shows a different response between portrait and landscape orientation. Step pattern is better reproduce by VIDAR scanner.

  9. High-Resolution Digitization of the Film Archive of SPRI/NSF/TUD Radar Sounding of the Antarctic Ice Sheet

    Science.gov (United States)

    Schroeder, D. M.; Dowdeswell, J. A.; Mackie, E. J.; Vega, K. I.; Emmons, J. R.; Winstein, K.; Bingham, R. G.; Benham, T. J.

    2017-12-01

    The airborne radio echo sounding data collected during the SPRI/NSF/TUD surveys of the Antarctic Ice Sheet in the late nineteen sixties and early seventies were recorded on a combination of 35mm and super-8 mm black-and-white optical film. These data represent the oldest extant continent-scale geophysical observations of ice thickness, internal layering and conditions beneath the Antarctic Ice Sheet. As such, when compared with modern radar sounding observations, they offer a unique opportunity to investigate temporal changes in ice sheet conditions across half a century. However, the storage of these data on film, paper-prints, and scans of those prints have made such comparison at the full radiometric and geometric resolution of the data difficult. To address this challenge, we utilized a state-of-the-art high-resolution Hollywood film scanning system to digitize the entire SPRI/NSF/TUD optical film archive. This has resulted in over two million digital images with information at the full spatial and brightness-level resolution of the original film. We present the process and results of this scanning as well as the current progress in formatting, registering, and positioning these data for release and use by the wider radio glaciological community. We also discuss the glaciological insights enabled by this effort.

  10. SU-E-P-16: A Feasibility Study of Using Eclipse AAA for SRS Treatement

    International Nuclear Information System (INIS)

    Lim, S; LoSasso, T

    2015-01-01

    Purpose: To commission Varian Eclipse AAA for SRS treatment and compare the accuracy with Brainlab iPlan system for clinical cases measured with radiochromic film. Methods: A 6MV AAA clinical model for a Varian TrueBeam STx is used as baseline. The focal spot and field size of the baseline model(BASE) are (1.75,0.75) and 40×40cm 2 respectively. Maximum field sizes, output factors(S t ), FWHM focal spot and secondary source sizes are systematically adjusted to obtain an optimized model(OPT) by comparing the calculated PDD’s, profiles, and output factors with measurements taken with a stereotactic diode(SD) and, cc01 and cc04 ion chambers in Blue Phantom. In-phantom dose distributions of clinical SRS fields are calculated using the OPT and the clinical Brainlab iPlan pencil-beam. Within the 90% isodose-line(ROI), the average dose difference between the calculations and radiochromic film measurements are assessed. Results: The maximum field, focal spot and secondary source sizes for the OPT are 15×15cm 2 , (0,0), and 32.3mm respectively. The OPT St input at 1.0 and 2.0cm fields are increased by 4.5% and 1.5% from BASE. The calculated output of the BASE and OPT underestimate by 16.1%–3.2% respectively at 0.5×0.5cm 2 field and 3.1%−0.02% respectively at 1.0×1.0cm 2 field. The depth doses at 10cm are within 3.5% and 0.4% of measurements for 0.5×0.5 and 1.0×1.0cm 2 . The ROI dose of OPT and iPlan are within 1.6% and 0.6% of film measurements for 3.0cm clinical fields. For 1.0cm fields, the ROI dose of OPT underestimate 0.0–2.0% and iPlan overestimates 1.7–2.9% relative to measurements. Conclusion: The small field dose calculation of Eclipse AAA algorithm can be significantly improved by carefully adjusting the input parameters. The larger deviation of the OPT for 0.5×0.5cm 2 field from measurements can be attributed to the lowest 1.0cm field size input limit of AAA. The OPT compares reasonably well with the iPlan pencil-beam and measurements

  11. SU-E-P-16: A Feasibility Study of Using Eclipse AAA for SRS Treatement

    Energy Technology Data Exchange (ETDEWEB)

    Lim, S; LoSasso, T [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2015-06-15

    Purpose: To commission Varian Eclipse AAA for SRS treatment and compare the accuracy with Brainlab iPlan system for clinical cases measured with radiochromic film. Methods: A 6MV AAA clinical model for a Varian TrueBeam STx is used as baseline. The focal spot and field size of the baseline model(BASE) are (1.75,0.75) and 40×40cm{sup 2} respectively. Maximum field sizes, output factors(S{sub t}), FWHM focal spot and secondary source sizes are systematically adjusted to obtain an optimized model(OPT) by comparing the calculated PDD’s, profiles, and output factors with measurements taken with a stereotactic diode(SD) and, cc01 and cc04 ion chambers in Blue Phantom. In-phantom dose distributions of clinical SRS fields are calculated using the OPT and the clinical Brainlab iPlan pencil-beam. Within the 90% isodose-line(ROI), the average dose difference between the calculations and radiochromic film measurements are assessed. Results: The maximum field, focal spot and secondary source sizes for the OPT are 15×15cm{sup 2}, (0,0), and 32.3mm respectively. The OPT St input at 1.0 and 2.0cm fields are increased by 4.5% and 1.5% from BASE. The calculated output of the BASE and OPT underestimate by 16.1%–3.2% respectively at 0.5×0.5cm{sup 2} field and 3.1%−0.02% respectively at 1.0×1.0cm{sup 2} field. The depth doses at 10cm are within 3.5% and 0.4% of measurements for 0.5×0.5 and 1.0×1.0cm{sup 2}. The ROI dose of OPT and iPlan are within 1.6% and 0.6% of film measurements for 3.0cm clinical fields. For 1.0cm fields, the ROI dose of OPT underestimate 0.0–2.0% and iPlan overestimates 1.7–2.9% relative to measurements. Conclusion: The small field dose calculation of Eclipse AAA algorithm can be significantly improved by carefully adjusting the input parameters. The larger deviation of the OPT for 0.5×0.5cm{sup 2} field from measurements can be attributed to the lowest 1.0cm field size input limit of AAA. The OPT compares reasonably well with the iPlan pencil

  12. Chitosan-caffeic acid-genipin films presenting enhanced antioxidant activity and stability in acidic media.

    Science.gov (United States)

    Nunes, Cláudia; Maricato, Élia; Cunha, Ângela; Nunes, Alexandra; da Silva, José A Lopes; Coimbra, Manuel A

    2013-01-02

    The use of chitosan films has been limited due to their high degradability in aqueous acidic media. In order to produce chitosan films with high antioxidant activity and insoluble in acid solutions caffeic acid was grafted to chitosan by a radical mechanism using ammonium cerium (IV) nitrate (60 mM). Genipin was used as cross-linker. This methodology originated films with 80% higher antioxidant activity than the pristine film. Also, these films only lost 11% of their mass upon seven days immersion into an aqueous solution at pH 3.5 under stirring. The films surface wettability (contact angle 105°), mechanical properties (68 MPa of tensile strength and 4% of elongation at break), and thermal stability for temperatures lower than 300 °C were not significantly influenced by the covalent linkage of caffeic acid and genipin to chitosan. Due to their characteristics, mainly higher antioxidant activity and lower solubility, these are promising materials to be used as active films. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Hydrogen in hydrogenated amorphous silicon thick film and its relation to the photoresponse of the film in contact with molybdenum

    International Nuclear Information System (INIS)

    Sridhar, N.; Chung, D.D.L.

    1992-01-01

    This paper reports that hydrogenated amorphous silicon films of thickness 0.5-7 μm on molybdenum substrates were deposited from silane by dc glow discharge and studied by mass spectrometric observation of the evolution of hydrogen upon heating and correlating this information with the photoresponse. The films were found to contain two types of hydrogen, namely weak bonded hydrogen, which evolved at 365 degrees C and was the minority, and strongly bonded hydrogen, which evolved at 460-670 degrees C and was the majority. The proportion of strongly bonded hydrogen increased with increasing film thickness and with increasing substrate temperature during deposition. The total amount of hydrogen increased when the substrate temperature was decreased from 350 to 275 degrees C. The strongly bonded hydrogen resided throughout the thickness of the film, whereas the weakly bonded hydrogen resided near the film surface. The evolution of the strongly bonded hydrogen was diffusion controlled, with an activation energy of 1.6 eV. The strongly bonded hydrogen enhanced the photoresponse, whereas the weakly bonded hydrogen degraded the photoresponse

  14. Magnetic field measurements of full length 50 mm aperture SSC dipole magnets at Fermilab

    International Nuclear Information System (INIS)

    Strait, J.; Bossert, R.; Carson, J.; Delchamps, S.W.; Gourlay, S.; Hanft, R.; Koska, W.; Kuchnir, M.; Lamm, M.J.; Mazur, P.O.; Mokhtarani, A.; Orris, D.; Ozelis, J.; Wake, M.; Devred, A.; DiMarco, J.; Kuzminski, J.; Puglisi, M.; Tompkins, J.C.; Yu, Y.; Zhao, Y.; Zheng, H.; Ogitsu, T.

    1992-09-01

    Thirteen 16 m long, 50 mm aperture SSC dipole magnets, designed jointly by Fermilab, Brookhaven National Laboratory, Lawrence Berkeley Laboratory and the SSC Laboratory, have been built at Fermilab. The first nine magnets have been fully tested to date. The allowed harmonics are systematically shifted from zero by amounts larger than the specification. The unallowed harmonics, with the exception of the skew sextupole, are consistent with zero. The magnet-to-magnet RMS variation of all harmonics is much smaller than the specification

  15. Mechanical, physico-chemical, and antimicrobial properties of gelatin-based film incorporated with catechin-lysozyme

    Directory of Open Access Journals (Sweden)

    Rawdkuen Saroat

    2012-11-01

    Full Text Available Abstract Background Microbial activity is a primary cause of deterioration in many foods and is often responsible for reduced quality and safety. Food-borne illnesses associated with E. coli O157:H7, S. aureus, S. enteritidis and L. monocytogenes are a major public health concern throughout the world. A number of methods have been employed to control or prevent the growth of these microorganisms in food. Antimicrobial packaging is one of the most promising active packaging systems for effectively retarding the growth of food spoilage and pathogenic microorganisms. The aim of this study was to determine the mechanical, physico-chemical properties and inhibitory effects of the fish gelatin films against selected food spoilage microorganisms when incorporated with catechin-lysozyme. Results The effect of the catechin-lysozyme combination addition (CLC: 0, 0.125, 0.25, and 0.5%, w/v on fish gelatin film properties was monitored. At the level of 0.5% addition, the CLC showed the greatest elongation at break (EAB at 143.17% with 0.039 mm thickness, and the lowest water vapor permeability (WVP at 6.5 x 10−8 g·mm·h-1·cm-2·Pa-1, whereas the control showed high tensile strength (TS and the highest WVP. Regarding color attributes, the gelatin film without CLC addition gave the highest lightness (L* 91.95 but lowest in redness (a*-1.29 and yellowness (b* 2.25 values. The light transmission of the film did not significantly decrease and nor did film transparency (p>0.05 with increased CLC. Incorporating CLC could not affect the film microstructure. The solubility of the gelatin based film incorporated with CLC was not affected, especially at a high level of addition (p>0.05. Inhibitory activity of the fish gelatin film against E.coli, S.aureus, L. innocua and S. cerevisiae was concentration dependent. Conclusions These findings suggested that CLC incorporation can improve mechanical, physico-chemical, and antimicrobial properties of the resulting films

  16. Nanocellulose-Zeolite Composite Films for Odor Elimination.

    Science.gov (United States)

    Keshavarzi, Neda; Mashayekhy Rad, Farshid; Mace, Amber; Ansari, Farhan; Akhtar, Farid; Nilsson, Ulrika; Berglund, Lars; Bergström, Lennart

    2015-07-08

    Free standing and strong odor-removing composite films of cellulose nanofibrils (CNF) with a high content of nanoporous zeolite adsorbents have been colloidally processed. Thermogravimetric desorption analysis (TGA) and infrared spectroscopy combined with computational simulations showed that commercially available silicalite-1 and ZSM-5 have a high affinity and uptake of volatile odors like ethanethiol and propanethiol, also in the presence of water. The simulations showed that propanethiol has a higher affinity, up to 16%, to the two zeolites compared with ethanethiol. Highly flexible and strong free-standing zeolite-CNF films with an adsorbent loading of 89 w/w% have been produced by Ca-induced gelation and vacuum filtration. The CNF-network controls the strength of the composite films and 100 μm thick zeolite-CNF films with a CNF content of less than 10 vol % displayed a tensile strength approaching 10 MPa. Headspace solid phase microextraction (SPME) coupled to gas chromatography-mass spectroscopy (GC/MS) analysis showed that the CNF-zeolite films can eliminate the volatile thiol-based odors to concentrations below the detection ability of the human olfactory system. Odor removing zeolite-cellulose nanofibril films could enable improved transport and storage of fruits and vegetables rich in odors, for example, onion and the tasty but foul-smelling South-East Asian Durian fruit.

  17. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  18. Micro-machined high-frequency (80 MHz) PZT thick film linear arrays.

    Science.gov (United States)

    Zhou, Qifa; Wu, Dawei; Liu, Changgeng; Zhu, Benpeng; Djuth, Frank; Shung, K

    2010-10-01

    This paper presents the development of a micromachined high-frequency linear array using PZT piezoelectric thick films. The linear array has 32 elements with an element width of 24 μm and an element length of 4 mm. Array elements were fabricated by deep reactive ion etching of PZT thick films, which were prepared from spin-coating of PZT sol-gel composite. Detailed fabrication processes, especially PZT thick film etching conditions and a novel transferring-and-etching method, are presented and discussed. Array designs were evaluated by simulation. Experimental measurements show that the array had a center frequency of 80 MHz and a fractional bandwidth (-6 dB) of 60%. An insertion loss of -41 dB and adjacent element crosstalk of -21 dB were found at the center frequency.

  19. PLD of X7R for thin film capacitors

    International Nuclear Information System (INIS)

    Hino, Takanori; Matsumoto, Noriyuki; Nishida, Minoru; Araki, Takao

    2008-01-01

    Thin film capacitors with a thickness of 200 nm were prepared on SrTiO 3 (1 0 0), (1 1 0) and (1 1 1) single crystal substrates at a temperature of 973 K by pulsed laser deposition (PLD) using a KrF excimer laser in an O 2 -O 3 atmosphere with a gas pressure of 1 Pa using an X7R sintered target. As a result, perovskite BaTiO 3 solid solution films were obtained. In the X7R thin films on (1 0 0) and (1 1 0) SrTiO 3 , only diffraction peaks with strong intensities from BaTiO 3 (1 0 0) and (1 1 0), respectively, were observed. X7R films on SrTiO 3 (1 1 1) were grown epitaxially oriented to the crystal plane direction of the substrate by inserting an initial homoepitaxial SrTiO 3 layer with a thickness of 4 nm. The X7R/SrTiO 3 film capacitors yielded a large volumetric efficiency of 50 μF/mm 3 and a temperature coefficient of capacitance (TCC) of -1.3% to 1.3% which satisfies the EIA standard specifications for X7R

  20. Simultaneous measurements of thermal conductivity and electrical conductivity of micro-machined Silicon films

    International Nuclear Information System (INIS)

    Hagino, H; Kawahara, Y; Goto, A; Miyazaki, K

    2012-01-01

    The in-plane effective thermal conductivity of free-standing Si thin films with periodic micropores was measured at -100 to 0 °C. The Si thin films with micropores were prepared from silicon-on-insulator (SOI) wafers by standard microfabrication processes. The dimensions of the free-standing Si thin films were 200μm×150μm×2 μm, with staggered 4 μm pores having an average pitch of 4 mm. The Si thin film serves both as a heater and thermometer. The average temperature rise of the thin film is a function of its in-plane thermal conductivity. The effective thermal conductivity was calculated using a simple one-dimensional heat conduction model. The measured thermal conductivity was much lower than that expected based on classical model evaluations. A significant phonon size effect was observed even in the microsized structures, and the mean free path for phonons is very long even at the room temperature.

  1. Application of fluoridated hydroxyapatite thin film coatings using KrF pulsed laser deposition.

    Science.gov (United States)

    Hashimoto, Yoshiya; Ueda, Mamoru; Kohiga, Yu; Imura, Kazuki; Hontsu, Shigeki

    2018-06-08

    Fluoridated hydroxyapatite (FHA) was investigated for application as an implant coating for titanium bone substitute materials in dental implants. A KrF pulsed excimer deposition technique was used for film preparation on a titanium plate. The compacts were ablated by laser irradiation at an energy density of 1 J/cm 2 on an area 1×1 mm 2 with the substrate at room temparature. Energydispersive spectrometric analysis of the FHA film revealed peaks of fluorine in addition to calcium and phosphorus. X-ray diffraction revealed the presence of crystalline FHA on the FHA film after a 10 h post annealing treatment at 450°C. The FHA film coating exhibited significant dissolution resistance to sodium phosphate buffer for up to 21 days, and favorable cell attachment of human mesenchymal stem cells compared with HA film. The results of this study suggest that FHA coatings are suitable for real-world implantation applications.

  2. Spatially Multiplexed Micro-Spectrophotometry in Bright Field Mode for Thin Film Characterization

    Directory of Open Access Journals (Sweden)

    Valerio Pini

    2016-06-01

    Full Text Available Thickness characterization of thin films is of primary importance in a variety of nanotechnology applications, either in the semiconductor industry, quality control in nanofabrication processes or engineering of nanoelectromechanical systems (NEMS because small thickness variability can strongly compromise the device performance. Here, we present an alternative optical method in bright field mode called Spatially Multiplexed Micro-Spectrophotometry that allows rapid and non-destructive characterization of thin films over areas of mm2 and with 1 μm of lateral resolution. We demonstrate an accuracy of 0.1% in the thickness characterization through measurements performed on four microcantilevers that expand an area of 1.8 mm2 in one minute of analysis time. The measured thickness variation in the range of few tens of nm translates into a mechanical variability that produces an error of up to 2% in the response of the studied devices when they are used to measure surface stress variations.

  3. Uses of polymer-alanine film/ESR dosimeters in dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Xie Liqing; Zhang Yinfeng; Dai Jinxian; Lu Ting; Chen Ruyi; Yang Hua

    1993-01-01

    Alanine ESR dosimetry is a reliable method, used in a various fields of ionizing radiation. The polymer-alanine film/ESR dosimeters of 0.3 -0.4 mm thickness were prepared and their dosimetric properties were studied for 60 Co γ photons and 3 - 5 MeV electrons in the dose range from 20 Gy to 100 kGy. The results show that under normal conditions the alanine calibration curves are linear in the dose range from 100 Gy to 10kGy. The dose profiles at the electron radiation field were measured with the film alanine dosimeters. The polymer-alanine film dosimeters were used for ion implantation of 400 keV ion implantor. Their dose response and energy dependence were investigated initially. (Author)

  4. Improved adaptability of polyaryl-ether-ether-ketone with texture pattern and graphite-like carbon film for bio-tribological applications

    Science.gov (United States)

    Ren, Siming; Huang, Jinxia; Cui, Mingjun; Pu, Jibin; Wang, Liping

    2017-04-01

    With the development of surface treatment technology, an increasing number of bearings, seals, dynamic friction drive or even biomedical devices involve a textured surface to improve lubrication and anti-wear. The present investigation has been conducted in order to evaluate the friction and wear behaviours of textured polyaryl-ether-ether-ketone (PEEK) coated with a graphite-like carbon (GLC) film sliding against stainless steel pin in biological medium. Compared with pure PEEK, the PEEK coated with GLC film shows excellent tribological performance with a low friction of 0.08 and long lifetime (wear volumes are about 3.78 × 10-4 mm3 for un-textured one and 2.60 × 10-4 mm3 for textured GLC film after 36,000 s of sliding) under physiological saline solution. In particular, the GLC film with appropriate dimple area density is effective to improve friction reduction and wear resistance properties of PEEK substrate under biological solution, which is attributed to the entrapment of wear debris in the dimples to inhibit the graphitization and the fluid dynamic pressure effect derived from the texture surface to increase the thickness in elastohydrodynamic lubrication (EHL) film during sliding motions. Moreover, the friction coefficient of GLC film under physiological saline solution decreases with the increase in the applied load. With the increasing applied load, the texture surface is responsible for accounting the improved wear resistance and a much lower graphitization of the GLC film during whole test.

  5. Fractionated stereotactic radiotherapy: A method to evaluate geometric and dosimetric uncertainties using radiochromic films

    International Nuclear Information System (INIS)

    Coscia, Gianluca; Vaccara, Elena; Corvisiero, Roberta; Cavazzani, Paolo; Ruggieri, Filippo Grillo; Taccini, Gianni

    2009-01-01

    In the authors' hospital, stereotactic radiotherapy treatments are performed with a Varian Clinac 600C equipped with a BrainLAB m3 micro-multileaf-collimator generally using the dynamic conformal arc technique. Patient immobilization during the treatment is achieved with a fixation mask supplied by BrainLAB, made with two reinforced thermoplastic sheets fitting the patient's head. With this work the authors propose a method to evaluate treatment geometric accuracy and, consequently, to determine the amount of the margin to keep in the CTV-PTV expansion during the treatment planning. The reproducibility of the isocenter position was tested by simulating a complete treatment on the anthropomorphic phantom Alderson Rando, inserting in between two phantom slices a high sensitivity Gafchromic EBT film, properly prepared and calibrated, and repeating several treatment sessions, each time removing the fixing mask and replacing the film inside the phantom. The comparison between the dose distributions measured on films and computed by TPS, after a precise image registration procedure performed by a commercial piece of software (FILMQA, 3cognition LLC (Division of ISP), Wayne, NJ), allowed the authors to measure the repositioning errors, obtaining about 0.5 mm in case of central spherical PTV and about 1.5 mm in case of peripheral irregular PTV. Moreover, an evaluation of the errors in the registration procedure was performed, giving negligible values with respect to the quantities to be measured. The above intrinsic two-dimensional estimate of treatment accuracy has to be increased for the error in the third dimension, but the 2 mm margin the authors generally use for the CTV-PTV expansion seems adequate anyway. Using the same EBT films, a dosimetric verification of the treatment planning system was done. Measured dose values are larger or smaller than the nominal ones depending on geometric irradiation conditions, but, in the authors' experimental conditions, always

  6. Mango core inner shell membrane template-directed synthesis of porous ZnO films and their application for enzymatic glucose biosensor

    Science.gov (United States)

    Zhou, Yu; Wang, Lei; Ye, Zhizhen; Zhao, Minggang; Cai, Hui; Huang, Jingyun

    2013-11-01

    Micro/nano-porous ZnO films were synthesized through a simple biotemplate-directed method using mango core inner shell membranes as templates. The achieved ZnO films with wrinkles on the surface are combined of large holes and small pores in the bulk. High specific surface area, numerous microspaces, and small channels for fluid circulation provided by this unique structure along with the good biocompatibility and electron communication features of ZnO material make the product an ideal platform for the immobilization of enzymes The fabricated glucose biosensor based on the porous ZnO films exhibits good selective detection ability of analyte with good stability, high sensitivity of 50.58 μA cm-2 mM-1 and a wide linear range of 0.2-5.6 mM along with a low detection limit of 10 μM.

  7. Epitaxial growth of ReS2(001) thin film via deposited-Re sulfurization

    Science.gov (United States)

    Urakami, Noriyuki; Okuda, Tetsuya; Hashimoto, Yoshio

    2018-02-01

    In this paper, we present the formation of large-size rhenium disulfide (ReS2) films via the sulfurization of Re films deposited on sapphire substrates. The effects of sulfurization temperature and pressure on the crystal quality were investigated. A [001]-oriented single crystal of ReS2 films with 6 × 10 mm2 area was realized. By sulfurizing Re films at 1100 °C, ReS2 films with well-defined sharp interfaces to c-plane sapphire substrates could be formed. Below and above the sulfurization temperature of 1100 °C, incomplete sulfurization and film degradation were observed. The twofold symmetry of the monocrystalline in-plane structure composed of Re-Re bonds along with Re-S bonds pointed to a distorted 1T structure, indicating that this structure is the most stable atomic arrangement for ReS2. For a S/Re compositional ratio equal to or slightly lower than 2.0, characteristic Raman vibrational modes with the narrowest line widths were observed. The typical absorption peak of ReS2 can be detected at 1.5 eV.

  8. Strong composite films with layered structures prepared by casting silk fibroin-graphene oxide hydrogels

    Science.gov (United States)

    Huang, Liang; Li, Chun; Yuan, Wenjing; Shi, Gaoquan

    2013-04-01

    Composite films of graphene oxide (GO) sheets and silk fibroin (SF) with layered structures have been prepared by facile solution casting of SF-GO hydrogels. The as-prepared composite film containing 15% (by weight, wt%) of SF shows a high tensile strength of 221 +/- 16 MPa and a failure strain of 1.8 +/- 0.4%, which partially surpass those of natural nacre. Particularly, this composite film also has a high modulus of 17.2 +/- 1.9 GPa. The high mechanical properties of this composite film can be attributed to its high content of GO (85 wt%), compact layered structure and the strong hydrogen bonding interaction between SF chains and GO sheets.Composite films of graphene oxide (GO) sheets and silk fibroin (SF) with layered structures have been prepared by facile solution casting of SF-GO hydrogels. The as-prepared composite film containing 15% (by weight, wt%) of SF shows a high tensile strength of 221 +/- 16 MPa and a failure strain of 1.8 +/- 0.4%, which partially surpass those of natural nacre. Particularly, this composite film also has a high modulus of 17.2 +/- 1.9 GPa. The high mechanical properties of this composite film can be attributed to its high content of GO (85 wt%), compact layered structure and the strong hydrogen bonding interaction between SF chains and GO sheets. Electronic supplementary information (ESI) available: XPS spectrum of the SF-GO hybrid film, SEM images of lyophilized GO dispersion and the failure surface of GO film. See DOI: 10.1039/c3nr00196b

  9. Diversion and injection of buprenorphine-naloxone film two years post-introduction in Australia.

    Science.gov (United States)

    Larance, Briony; Mattick, Richard; Ali, Robert; Lintzeris, Nicholas; Jenkinson, Rebecca; White, Nancy; Kihas, Ivana; Cassidy, Rosemary; Degenhardt, Louisa

    2016-01-01

    We report 2 years of post-marketing surveillance of the diversion and injection of buprenorphine-naloxone (BNX) film following its introduction in 2011. Interviews were conducted with people who inject drugs regularly (PWID) (2004-2013), opioid substitution therapy clients (2013, n = 492) and key experts (n = 44). Key outcomes were unsanctioned removal of supervised doses, diversion, injection and street price. Prevalence of past 6-month injection among PWID was adjusted for background availability of opioid substitution therapy medications using sales data. Among out-of-treatment PWID, the levels of regular (weekly+) BNX film injection were comparable to methadone and BNX tablets, and lower than mono-buprenorphine, adjusting for background availability. Fewer BNX film clients [3%; 95% (CI) 1-5] regularly injected their medication than mono-buprenorphine clients (25%; 95% CI 11-39), but at levels equivalent to those among methadone (3%; 95% CI 1-6) and BNX tablet clients (2%; 95% CI 0-6). Key experts perceived BNX film needed less supervised dosing time as it dissolved rapidly and was harder to remove from the mouth than sublingual tablets; however, removal of supervised doses was higher among BNX film clients (15%; 95% CI: 10-20) than methadone clients (3%; 95% CI 1-6), and not significantly different from BNX tablet (11%; 95% CI 2-21) and mono-buprenorphine clients (31%; 95% CI 16-46). Two years post-introduction, levels of BNX film diversion and injection remained comparable with those for methadone and BNX tablets, and lower than mono-buprenorphine. We found no evidence that BNX film has lower non-adherence and diversion than the tablet formulation. [Larance B, Mattick R, Ali R, Lintzeris N, Jenkinson R, White N, Kihas I, Cassidy R, Degenhardt L. Diversion and injection of buprenorphine-naloxone film two years post-introduction in Australia. Drug Alcohol Rev 2015]. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  10. The deposition of thin metal films at the high-intensity pulsed-ion-beam influence on the metals

    International Nuclear Information System (INIS)

    Remnev, G.E.; Zakoutaev, A.N.; Grushin, I.I.; Matvenko, V.M.; Potemkin, A.V.; Ryzhkov, V.A.; Chernikov, E.V.

    1996-01-01

    A high-intensity pulsed ion beam with parameters: ion energy 350-500 keV, ion current density at a target > 200 A/cm 2 , pulse duration 60 ns, was used for metal deposition. The film deposition rate was 0.6-4.0 mm/s. Transmission electron microscopy/transmission electron diffraction investigations of the copper target-film system were performed. The impurity content in the film was determined by x-ray fluorescence analysis and secondary ion mass spectrometry. The angular distributions of the ablated plasma were measured. (author). 2 figs., 7 refs

  11. The deposition of thin metal films at the high-intensity pulsed-ion-beam influence on the metals

    Energy Technology Data Exchange (ETDEWEB)

    Remnev, G E; Zakoutaev, A N; Grushin, I I; Matvenko, V M; Potemkin, A V; Ryzhkov, V A [Tomsk Polytechnic Univ. (Russian Federation). Nuclear Physics Inst.; Ivanov, Yu F [Construction Academy, Tomsk (Russian Federation); Chernikov, E V [Siberian Physical Technical Institute, Tomsk (Russian Federation)

    1997-12-31

    A high-intensity pulsed ion beam with parameters: ion energy 350-500 keV, ion current density at a target > 200 A/cm{sup 2}, pulse duration 60 ns, was used for metal deposition. The film deposition rate was 0.6-4.0 mm/s. Transmission electron microscopy/transmission electron diffraction investigations of the copper target-film system were performed. The impurity content in the film was determined by x-ray fluorescence analysis and secondary ion mass spectrometry. The angular distributions of the ablated plasma were measured. (author). 2 figs., 7 refs.

  12. Influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation and nodules on 16- and 64-detector row CT systems: experimental study using chest phantom.

    Science.gov (United States)

    Ohno, Yoshiharu; Koyama, Hisanobu; Kono, Astushi; Terada, Mari; Inokawa, Hiroyasu; Matsumoto, Sumiaki; Sugimura, Kazuro

    2007-12-01

    The purpose of the present study was to determine the influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation (GGA) and nodules on 16- and 64-detector row CTs, by using a commercially available chest phantom. A chest CT phantom including simulated GGAs and nodules was scanned with different detector collimations, beam pitches and tube currents. The probability and image quality of each simulated abnormality was visually assessed with a five-point scoring system. ROC-analysis and ANOVA were then performed to compare the identification and image quality of either protocol with standard values. Detection rates of low-dose CTs were significantly reduced when tube currents were set at 40mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32mmx1.0mm for low pitch, and at 100mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32mmx1.0mm for high pitch (pdetector collimation 16 and 64x0.5mm and 16 and 32x1.0mm for low pitch, and at 150mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32x1.0mm for high pitch (pDetector collimation and beam pitch were important factors for the image quality and identification of GGA and nodules by 16- and 64-detector row CT.

  13. The challenges encountered in the integration of an early test wafer surface scanning inspection system into a 450mm manufacturing line

    Science.gov (United States)

    Lee, Jeffrey; McGarvey, Steve

    2013-04-01

    The introduction of early test wafer (ETW) 450mm Surface Scanning Inspection Systems (SSIS) into Si manufacturing has brought with it numerous technical, commercial, and logistical challenges on the path to rapid recipe development and subsequent qualification of other 450mm wafer processing equipment. This paper will explore the feasibility of eliminating the Polystyrene Latex Sphere deposition process step and the subsequent creation of SSIS recipes based upon the theoretical optical properties of both the SSIS and the process film stack(s). The process of Polystyrene Latex Sphere deposition for SSIS recipe generation and development is generally accepted on the previous technology nodes for 150/200/300mm wafers. PSL is deposited with a commercially available deposition system onto a non-patterned bare Si or non-patterned filmed Si wafer. After deposition of multiple PSL spots, located in different positions on a wafer, the wafer is inspected on a SSIS and a response curve is generated. The response curve is based on the the light scattering intensity of the NIST certified PSL that was deposited on the wafer. As the initial 450mm Si wafer manufacturing began, there were no inspection systems with sub-90nm sensitivities available for defect and haze level verification. The introduction of a 450mm sub-30nm inspection system into the manufacturing line generated instant challenges. Whereas the 450mm wafers were relatively defect free at 90nm, at 40nm the wafers contained several hundred thousand defects. When PSL was deposited onto wafers with these kinds of defect levels, PSL with signals less than the sub-90nm defects were difficult to extract. As the defectivity level of the wafers from the Si suppliers rapidly improves the challenges of SSIS recipe creation with high defectivity decreases while at the same time the cost of PSL deposition increases. The current cost per wafer is fifteen thousand dollars for a 450mm PSL deposition service. When viewed from the

  14. Realization of hexagonal barium ferrite thick films on Si substrates using a screen printing technique

    International Nuclear Information System (INIS)

    Chen Yajie; Smith, Ian; Geiler, Anton L; Vittoria, Carmine; Harris, Vincent G; Zagorodnii, Volodymyr; Celinski, Zbigniew

    2008-01-01

    Hexagonal barium ferrite thick films (50-200 μm) have been deposited on Si and Al 2 O 3 /Si substrates using a screen printing technique. X-ray diffractometry, scanning electron microscopy and magnetometry were used to characterize and correlate the ferrite films' microstructure and magnetic properties. The experiments indicated that an Al 2 O 3 underlayer was effective in preventing silicon diffusion into the barium ferrite films during a final sintering treatment at temperatures above 1100 deg. C. A two-stage sintering process allowed a reasonable tradeoff between mechanical and magnetic properties. This work reveals the feasibility of fabrication of thick ferrite films on large substrates (up to 25 mm in diameter) for future planar microwave devices compatible with semiconductor integrated circuits processing

  15. Effects of B2O3-Li2O additions on the dielectric properties of screen printing Ba0.6Sr0.4TiO3 thick films

    International Nuclear Information System (INIS)

    Zeng, Yike; Gao, Can; Zhang, Guangzu; Jiang, Shenglin

    2012-01-01

    Ba 0.6 Sr 0.4 TiO 3 (BST) thick films were fabricated on Al 2 O 3 substrate via the screen printing technology by using B 2 O 3 -Li 2 O additions as liquid-phase sintering aids. The effects of doping of B 2 O 3 and Li 2 CO 3 on the phase compositions, microstructures, and dielectric tunable properties of the thick films were investigated systematically. The X-ray diffraction patterns showed that BST diffraction peaks shifted toward higher angle with the B 2 O 3 -Li 2 O doping content, which indicated the substitution of B 3+ and Li + in Ba 2+ site. It was also found that the grain size and electrical properties of the thick film were strongly affected by the glass content. The grain size and the relative permittivity decreased obviously with the increase of B 2 O 3 -Li 2 O additive. In addition, for the thick film with 4.5 wt% glass content, optimized sintering, and electrical properties were obtained: the sintering temperature of 900 C, relative permittivity of 312 (at 10 kHz), dielectric loss of 0.0039, tunability of 16.2% (at 3 kV/mm). These good sintering and electrical properties indicate that BST thick film with B 2 O 3 -Li 2 O addition is benefit for the development of LTCC technology and tunable devices. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. NO2 sensing properties of amorphous silicon films

    International Nuclear Information System (INIS)

    Georgieva, V; Gadjanova, V; Donkov, N; Stefanov, P; Sendova-Vassileva, M; Grechnikov, A

    2012-01-01

    The sensitivity to NO 2 was studied of amorphous silicon thin films obtained by e-beam evaporation. The process was carried out at an operational-mode vacuum of 1.5x10 -5 Torr at a deposition rate of 170 nm/min. The layer's structure was analyzed by Raman spectroscopy, while its composition was determined by X-ray photoemission spectroscopy (XPS). To estimate their sensitivity to NO 2 , the Si films were deposited on a 16-MHz quartz crystal microbalance (QCM) and the correlation was used between the QCM frequency variation and the mass-loading after exposure to NO 2 in concentrations from 10 ppm to 5000 ppm. A considerable sensitivity of the films was found in the interval 1000 ppm-2500 ppm NO 2 , leading to frequency shifts from 131 Hz to 208 Hz. The results obtained on the films' sorption properties can be applied to the development sensor elements.

  17. Lipase immobilized on nanostructured cerium oxide thin film coated on transparent conducting oxide electrode for butyrin sensing

    Energy Technology Data Exchange (ETDEWEB)

    Panky, Sreedevi; Thandavan, Kavitha [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Chemical and Biotechnology, SASTRA University, Thanjavur 613 401, Tamil Nadu (India); Sivalingam, Durgajanani [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Electrical and Electronics Engineering, SASTRA University, Thanjavur 613 401, Tamil Nadu (India); Sethuraman, Swaminathan; Krishnan, Uma Maheswari [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Chemical and Biotechnology, SASTRA University, Thanjavur 613 401, Tamil Nadu (India); Jeyaprakash, Beri Gopalakrishnan [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Electrical and Electronics Engineering, SASTRA University, Thanjavur 613 401, Tamil Nadu (India); Rayappan, John Bosco Balaguru, E-mail: rjbosco@ece.sastra.edu [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Electrical and Electronics Engineering, SASTRA University, Thanjavur 613 401, Tamil Nadu (India)

    2013-01-15

    Nanostructured cerium oxide (CeO{sub 2}) thin films were deposited on transparent conducting oxide (TCO) substrate using spray pyrolysis technique with cerium nitrate salt, Ce(NO{sub 3}){sub 3}{center_dot}6H{sub 2}O as precursor. Fluorine doped cadmium oxide (CdO:F) thin film prepared using spray pyrolysis technique acts as the TCO film and hence the bare electrode. The structural, morphological and elemental characterizations of the films were carried out using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray analysis (EDX) respectively. The diffraction peak positions in XRD confirmed the formation of highly crystalline ceria with cubic structure and FE-SEM images showed uniform adherent films with granular morphology. The band gaps of CeO{sub 2} and TCO were found to be 3.2 eV and 2.6 eV respectively. Lipase enzyme was physisorbed on the surface of CeO{sub 2}/TCO film to form the lipase/nano-CeO{sub 2}/TCO bioelectrode. Sensing studies were carried out using cyclic voltammetry and amperometry, with lipase/nano-CeO{sub 2}/TCO as working electrode and tributyrin as substrate. The mediator-free biosensor with nanointerface exhibited excellent linearity (0.33-1.98 mM) with a lowest detection limit of 2 {mu}M with sharp response time of 5 s and a shelf life of about 6 weeks. -- Graphical abstract: Nanostructured cerium oxide thin films were deposited on transparent conducting oxide (TCO) substrate using spray pyrolysis technique. Fluorine doped cadmium oxide (CdO:F) thin film acts as the TCO film and hence the working electrode. Lipase enzyme was physisorbed on the surface of CeO{sub 2}/TCO film and hence the lipase/nano-CeO{sub 2}/TCO bioelectrode has been fabricated. Sensing studies were carried out using cyclic voltammetry and amperometry with tributyrin as substrate. The mediator-free biosensor with nanointerface exhibited excellent linearity (0.33-1.98 mM) with a lowest detection limit of 2 {mu}M with sharp

  18. PWV, Temperature and Wind Statistics at Sites Suitable For mm and Sub-mm Wavelengths Astronomy

    Science.gov (United States)

    Otarola, Angel; Travouillon, Tony; De Breuck, Carlos; Radford, Simon; Matsushita, Satoki; Pérez-Beaupuits, Juan P.

    2018-01-01

    Atmospheric water vapor is the main limiting factor of atmospheric transparency in the mm and sub-mm wavelength spectral windows. Thus, dry sites are needed for the installation and successful operation of radio astronomy observatories exploiting those spectral windows. Other parameters that play an important role in the mechanical response of radio telescopes exposed to the environmental conditions are: temperature, and in particular temperature gradients that induce thermal deformation of mechanical structures, as well as wind magnitude that induce pointing jitter affecting this way the required accuracy in the ability to point to a cosmic source during the observations. Temperature and wind are variables of special consideration when planning the installation and operations of large aperture radio telescopes. This work summarizes the statistics of precipitable water vapor (PWV), temperature and wind monitored at sites by the costal mountain range, as well as on t he west slope of the Andes mountain range in the region of Antofagasta, Chile. This information could prove useful for the planning of the Atacama Large-Aperture Submm/mm Telescope (AtLast).

  19. Development of a novel scintillation-trigger detector for the MTV experiment using aluminum-metallized film tapes

    Science.gov (United States)

    Tanaka, S.; Ozaki, S.; Sakamoto, Y.; Tanuma, R.; Yoshida, T.; Murata, J.

    2014-07-01

    A new type of a trigger-scintillation counter array designed for the MTV experiment at TRIUMF-ISAC has been developed, which uses aluminum-metallized film tape for wrapping to achieve the required assembling precision of ±0.5 mm. The MTV experiment uses a cylindrical drift chamber (CDC) as the main electron-tracking detector. The barrel-type trigger counter is placed inside the CDC to generate a trigger signal using 1 mm thick, 300 mm long thin plastic scintillation counters. Detection efficiency and light attenuation compared with conventional wrapping materials are studied.

  20. Development of a novel scintillation-trigger detector for the MTV experiment using aluminum-metallized film tapes

    International Nuclear Information System (INIS)

    Tanaka, S.; Ozaki, S.; Sakamoto, Y.; Tanuma, R.; Yoshida, T.; Murata, J.

    2014-01-01

    A new type of a trigger-scintillation counter array designed for the MTV experiment at TRIUMF-ISAC has been developed, which uses aluminum-metallized film tape for wrapping to achieve the required assembling precision of ±0.5 mm. The MTV experiment uses a cylindrical drift chamber (CDC) as the main electron-tracking detector. The barrel-type trigger counter is placed inside the CDC to generate a trigger signal using 1 mm thick, 300 mm long thin plastic scintillation counters. Detection efficiency and light attenuation compared with conventional wrapping materials are studied

  1. Preventing bacterial growth on implanted device with an interfacial metallic film and penetrating X-rays.

    Science.gov (United States)

    An, Jincui; Sun, An; Qiao, Yong; Zhang, Peipei; Su, Ming

    2015-02-01

    Device-related infections have been a big problem for a long time. This paper describes a new method to inhibit bacterial growth on implanted device with tissue-penetrating X-ray radiation, where a thin metallic film deposited on the device is used as a radio-sensitizing film for bacterial inhibition. At a given dose of X-ray, the bacterial viability decreases as the thickness of metal film (bismuth) increases. The bacterial viability decreases with X-ray dose increases. At X-ray dose of 2.5 Gy, 98% of bacteria on 10 nm thick bismuth film are killed; while it is only 25% of bacteria are killed on the bare petri dish. The same dose of X-ray kills 8% fibroblast cells that are within a short distance from bismuth film (4 mm). These results suggest that penetrating X-rays can kill bacteria on bismuth thin film deposited on surface of implant device efficiently.

  2. Dielectric, ferroelectric, and thermodynamic properties of silicone oil modified PVDF films for energy storage application

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Bingcheng; Wang, Xiaohui, E-mail: wxh@tsinghua.edu.cn, E-mail: llt-dms@mail.tsinghua.edu.cn; Li, Longtu, E-mail: wxh@tsinghua.edu.cn, E-mail: llt-dms@mail.tsinghua.edu.cn [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Sun, Hui [Aero-Engine Control System Institute, Aviation Industry Corporation of China, Jiangsu, Wuxi 214063 (China)

    2016-06-13

    Silicone oil modified poly(vinylidene fluoride-co-hexafluoropropylene) (P(VDF-HFP)) films were fabricated by the blending, casting, and hot-molding methods. The dielectric constant was increased for the 7.4 wt. % and 17.0 wt. % silicone oil modified P(VDF-HFP) films, while the dielectric loss for all blend films are decreased. D-E loops of 7.4 wt. % and 17.0 wt. % silicone oil modified P(VDF-HFP) films become slimmer than the pristine P(VDF-HFP) films. The maximum discharged energy density of 10.3 J/cm{sup 3} was obtained in 7.4 wt. % silicone oil modified P(VDF-HFP) films at the external electric field of 398 kV/mm. The Gibbs energy, miscibility, and phase behavior of binary mixture of P(VDF-HFP) silicone oil were investigated using molecular simulations and the extended Flory–Huggins model revealing favorable interactions and compatibility between P(VDF-HFP) and silicone oil.

  3. Development of highly flexible and ultra-low permeation rate thin-film barrier structure for organic electronics

    International Nuclear Information System (INIS)

    Kim, Namsu; Graham, Samuel

    2013-01-01

    A flexible thin-film encapsulation architecture for organic electronics was built and consisted of a silicon oxide/alumina and parylene layer deposited over Ca sensors on a barrier-coated polyethylene terephthalate substrate. The film's effective water vapor transmission rate was 2.4 ± 1.5 × 10 −5 g/m 2 /day at 20 °C and 50% relative humidity. Flexural tests revealed that for films deposited on the polyethylene terephthalate substrate, the barrier layer failed due to cracking at a curvature radius of 6.4 mm, corresponding to a strain of 0.8%. Adding an epoxy top coat of suitable thickness shifted the neutral axis toward the encapsulation layer, reducing the induced strain. Barrier performance was maintained under the 6.4 mm radius of curvature in this encapsulation structure. Thus, shifting the neutral axis via device structural design is an effective method of extending the flexibility of thin-film encapsulation structure without compromising the performance loss as a barrier layer. - Highlights: • High performance barrier is fabricated on flexible substrate. • The water vapor transmission rate is 2.4 ± 1.5 × 10 −5 g/m 2 /day. • The structure maintains its performance under a small radius of bending curvature

  4. Theoretical analysis of film condensation in horizontal microfin tubes; Microfin tsuki suihei kannai gyoshuku no riron kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Honda, H; Wang, H [Kyushu University, Fukuoka (Japan). Institute of Advanced Material Study; Nozu, S [Okamaya Prefectural University, Okayama (Japan). Faculty of Computer Science and System Engineering

    2000-10-25

    A theoretical study has been made of film condensation in helically-grooved, horizontal microfin tubes. The annular flow regime and the stratified flow regime were considered. For the annular flow regime, a previously developed theoretical model was applied. For the stratified flow regime, the height of stratified condensate was estimated by a modified Taitel and Dukler model. For the upper part of the tube exposed to the vapor flow, numerical calculation of Laminar film condensation considering the combined effects of gravity and surface tension forces was conducted. The heat transfer coefficient at the lower part of the tube was estimated by an empirical equation for the internally finned tubes developed by Carnavos. The theoretical predictions of the circumferential average heat transfer coefficient by the two theoretical models were compared with available experimental data for four refrigerants and four tubes. Generally, the annular flow model gave a higher heat transfer coefficient than the stratified flow model in the high quality region, whereas the stratified flow model gave a higher heat transfer coefficient in the low quality region. For tubes with fin heights of 0.16 {approx} 0.24 mm, most of the experimental data agreed within {+-} 20% with the higher of the two theoretical predictions. (author)

  5. Optical and electrical properties of chemical bath deposited cobalt sulphide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Govindasamy, Geetha [R& D Centre, Bharathiar University, Coimbatore (India); Murugasen, Priya, E-mail: priyamurugasen15@gmail.com [Department of Physics, Saveetha Engineering, Chennai, Tamil Nadu (India); Sagadevan, Suresh [Department of Physics, AMET University, Chennai, Tamil Nadu (India)

    2017-01-15

    Cobalt sulphide (CoS) thin films were synthesized using the Chemical Bath Deposition (CBD) technique. X-ray diffraction (XRD) analysis was used to study the structure and the crystallite size of CoS thin film. Scanning Electron Microscope (SEM) studies reveal the surface morphology of these films. The optical properties of the CoS thin films were determined using UV-Visible absorption spectrum. The optical band gap of the thin films was found to be 1.6 eV. Optical constants such as the refractive index, the extinction coefficient and the electric susceptibility were determined. The dielectric studies were carried out at different frequencies and at different temperatures for the prepared CoS thin films. In addition, the plasma energy of the valence electron, Penn gap or average energy gap, the Fermi energy and electronic polarizability of the thin films were determined. The AC electrical conductivity measurement was also carried out for the thin films. The activation energy was determined by using DC electrical conductivity measurement. (author)

  6. Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm. A single-institution experience

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ying-Yueh [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); Chen, Chun-Ku [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China); National Yang-Ming University, Institute of Clinical Medicine, Taipei (China); Yeh, Yi-Chen [National Yang-Ming University, School of Medicine, Taipei (China); Taipei Veterans General Hospital, Department of Pathology and Laboratory Medicine, Taipei (China); Wu, Mei-Han [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China)

    2018-02-15

    This retrospective study evaluated the diagnostic yield and safety of CT-guided core biopsy of pulmonary nodules ≤8 mm. We determined the diagnostic yield and safety profile of CT-guided lung biopsies for 125 pulmonary nodules ≤8 mm. Pathological diagnoses were made by a combination of histopathological examination and imprint cytology. Results were compared with biopsy results for 134 pulmonary nodules >8 and ≤10 mm. Final diagnoses were established in 94 nodules ≤8 mm. The sensitivity, specificity and diagnostic accuracy of CT-guided core biopsy for nodules ≤8 mm were 87.1 % (61/70 nodules), 100 % (24/24) and 90.4 % (85/94), respectively. Diagnostic failure rates were comparable for nodules ≤8 mm and nodules >8 mm and ≤10 mm (9/94, 9.6 % and 7/111, 6.3 %, respectively, P=0.385). The rate of tube thoracostomy for nodules ≤8 mm was comparable to that for nodules >8 and ≤10 mm (1.6 % vs. 0.7 %, P=0.611). Nodules ≤6 mm had a higher non-diagnostic result rate of 15.4 % (6/39) than did nodules >8 and ≤10 mm (3.7 %, 5/134, P=0.017). CT-guided pulmonary biopsy is feasible for lung nodules ≤8 mm, especially those >6 mm, and has an acceptable diagnostic yield and safety profile. (orig.)

  7. Experimental study of interfacial wave on a liquid film in vertical annular flow

    International Nuclear Information System (INIS)

    Hazuku, T.; Fukamachi, N.; Takamasa, T.; Matsumoto, Y.

    2003-01-01

    In this study, a precise database of microscopic interfacial wave-structure for annular flow developing in a vertical pipe was obtained using a new measuring technique with a laser focus displacement meter. Adiabatic upward annular air-water flow experiments were conducted using a 3-m-long, 11- mm-ID pipe. Measurements of interfacial waves were conducted at 21 axial locations, spaced 110 mm apart, in the pipe. The axial distances from the inlet (L) normalized by the pipe diameter (D) varied over L/D = 50 to 250. Data were collected for predetermined gas and liquid flow conditions and for Reynolds numbers ranging from Reg = 31,800 to 98,300 for the gas phase and Ref = 1,050 to 9,430 for the liquid phase. Using this new technique, we obtained such local properties as the minimum thickness, maximum thickness, and passing frequency of the waves. The results revealed that the maximum film thickness and passing frequency of disturbance waves decreased gradually, with some oscillations, as flow developed. The flow development, i.e., decreases of film thickness and passing frequency, existed until the pipe exit, which means that the flow might never reach a fully developed condition. Minimum thickness of the film decreased with flow development and with increasing gas flow rate. These results are discussed, taking into account the buffer layer calculated from Karman's three-layer model. Correlation is proposed for the minimum film thickness obtained in regard to interfacial shear stress and the Reynolds number of the liquid. This correlation expresses the minimum film thickness obtained from the experiment within a 5% deviation

  8. Development and characterization of collagen films with added essential oil of clove india

    Directory of Open Access Journals (Sweden)

    Ailim Yuki Nakashima

    2016-03-01

    Full Text Available This objective of this study was to develop and characterized films based on collagen and analyze the effects of concentrations of clay, plasticizer and essential oil on its characteristics. The solutions were prepared according to an experimental design of 2³ with 3 central points. The films were produced by the "casting" technique, which consists on surface drying, and were characterized by the color, opacity, tensile strength, solubility, water vapor permeability and thickness. Lightness values ranged between 66.76 and 96.03, the brightness decreased with increasing the concentrations of clay, oil and glycerol. The opacity values showed an increase with the addition of glycerol, ranging from 1.96 to 44.24%. The values of tensile strength ranged from 5 to 14 MPa, and the solubility values, from 2.14 to 7.97%. In the 5% level, solubility and tensile strength analyzes were not significant. The water vapor permeability (WVP ranged from 0.77 to 2.51 (g.mm/KPa.m2.d. The most influent factors on the permeability to water vapor in the films are the glycerol and essential oil concentrations, which increases the permeability as these variables increase. In relation to the thickness, the concentration of montmorillonite clay interfered in the range from 0.02 to 0.04mm, and as higher its concentration, greater the thickness. It was concluded that the collagen films obtained good mechanical properties, adequate visual appearance, easy handing and low permeability to water vapor and low water solubility. The essential oil was effective in the structure of the film, since that it improves the look and easier handling.

  9. Thermoelectric Mixed Thick-/Thin Film Microgenerators Based on Constantan/Silver

    Directory of Open Access Journals (Sweden)

    Mirosław Gierczak

    2018-01-01

    Full Text Available This paper describes the design, manufacturing and characterization of newly developed mixed thick-/thin film thermoelectric microgenerators based on magnetron sputtered constantan (copper-nickel alloy and screen-printed silver layers. The thermoelectric microgenerator consists of sixteen thermocouples made on a 34.2 × 27.5 × 0.25 mm3 alumina substrate. One of thermocouple arms was made of magnetron-sputtered constantan (Cu-Ni alloy, the second was a Ag-based screen-printed film. The length of each thermocouple arm was equal to 27 mm, and their width 0.3 mm. The distance between the arms was equal to 0.3 mm. In the first step, a pattern mask with thermocouples was designed and fabricated. Then, a constantan layer was magnetron sputtered over the whole substrate, and a photolithography process was used to prepare the first thermocouple arms. The second arms were screen-printed onto the substrate using a low-temperature silver paste (Heraeus C8829A or ElectroScience Laboratories ESL 599-E. To avoid oxidation of constantan, they were fired in a belt furnace in a nitrogen atmosphere at 550/450 °C peak firing temperature. Thermoelectric and electrical measurements were performed using the self-made measuring system. Two pyrometers included into the system were used for temperature measurement of hot and cold junctions. The estimated Seebeck coefficient, α was from the range 35 − 41 µV/K, whereas the total internal resistances R were between 250 and 3200 ohms, depending on magnetron sputtering time and kind of silver ink (the resistance of a single thermocouple was between 15.5 and 200 ohms.

  10. Tribological Behaviour of Ti:Ta-DLC Films Under Different Tribo-Test Conditions

    Science.gov (United States)

    Efeoglu, İhsan; Keleş, Ayşenur; Totik, Yaşar; Çiçek, Hikmet; Emine Süküroglu, Ebru

    2018-01-01

    Diamond-like carbon (DLC) films are suitable applicants for cutting tools due to their high hardness, low friction coefficient and wear rate. Doping metals in DLC films have been improved its tribological properties. In this study, titanium and tantalum doped hydrogenated DLC films were deposited by closed-field unbalanced magnetron sputtering system onto M2 high speed steels in Ar/N2/C2H2 atmosphere. The friction and wear properties of Ti:Ta-DLC film were investigated under different tribo-test conditions including in atmospheric pressure, distilled water, commercial oil and Ar atmosphere. The coated specimens were characterized by SEM and X-ray diffraction techniques. The bonding state of C-C (sp3) and C=C (sp2) were obtained with XPS. The tribological properties of Ti:Ta-DLC were investigated with pin-on-disc wear test. Hardness measurements performed by micro-indentation. Our results suggest that Ti:Ta-doped DLC film shows very dense columnar microstructure, high hardness (38.2 GPa) with low CoF (µ≈0.02) and high wear resistance (0.5E-6 mm3/Nm).

  11. Dynamic measurement of the corneal tear film with a Twyman-Green interferometer

    Science.gov (United States)

    Micali, Jason D.; Greivenkamp, John E.; Primeau, Brian C.

    2015-05-01

    An interferometer for measuring dynamic properties of the in vivo tear film on the human cornea has been developed. The system is a near-infrared instantaneous phase-shifting Twyman-Green interferometer. The laser source is a 785 nm solid-state laser, and the system has been carefully designed and calibrated to ensure that the system operates at eye-safe levels. Measurements are made over a 6 mm diameter on the cornea. Successive frames of interferometric height measurements are combined to produce movies showing both the quantitative and qualitative changes in the topography of the tear film surface and structure. To date, measurement periods of up to 120 s at 28.6 frames per second have been obtained. Several human subjects have been examined using this system, demonstrating a surface height resolution of 25 nm and spatial resolution of 6 μm. Examples of features that have been observed in these preliminary studies of the tear film include postblink disruption, evolution, and stabilization of the tear film; tear film artifacts generated by blinking; tear film evaporation and breakup; and the propagation of foreign objects in the tear film. This paper discusses the interferometer design and presents results from in vivo measurements.

  12. Development and Characterization of Edible Films Based on Fruit and Vegetable Residues.

    Science.gov (United States)

    Andrade, Roberta M S; Ferreira, Mariana S L; Gonçalves, Édira C B A

    2016-02-01

    Edible films were developed from the solid residue of the processing of whole fruits and vegetables. The solid residue, processed into flour (FVR flour) was chemically and structurally characterized by microstructure, elemental composition, structural links, and moisture sorption isotherm. Films were prepared by casting using aqueous extracts of 8% and 10% of flour (w/w) and characterized in terms of thickness, water solubility, mechanical properties, water vapor permeability, and Fourier transform infrared (FTIR). The analysis of microstructure and elemental composition, performed on flour (mean particle size 350 μm), showed an essentially granular aspect, with the presence of fibrous particles having potassium as one of the most abundant elements. FTIR results showed similarity between the characteristic bands of other raw materials used in edible films. The sorption isotherm of FVR flour showed a typical profile of foods rich in soluble components, such as sugars. Dried films presented an average thickness of 0.263 ± 0.003 mm, a homogenous aspect, bright yellow color, pronounced fruit flavor, and high water solubility. The FTIR spectra of the edible films revealed that addition of potato skin flour did not change the molecular conformation. Moreover, the films presented low tensile strength at break when compared with fruit starch-based films. © 2016 Institute of Food Technologists®

  13. Charpy impact test results on five materials and NIST verification specimens using instrumented 2-mm and 8-mm strikers

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Sokolov, M.A.

    1995-01-01

    The Heavy-Section Steel Irradiation Program at Oak Ridge National Laboratory is involved in two cooperative projects, with international participants, both of which involve Charpy V-notch impact tests with instrumented strikers of 2mm and 8mm radii. Two heats of A 533 grade B class I pressure vessel steel and a low upper-shelf (LUS) submerged-arc (SA) weld were tested on the same Charpy machine, while one heat of a Russian Cr-Mo-V forging steel and a high upper-shelf (HUS) SA weld were tested on two different machines. The number of replicate tests at any one temperature ranged from 2 to 46 specimens. Prior to testing with each striker, verification specimens at the low, high, and super high energy levels from the National Institute of Standards and Technology (NIST) were tested. In the two series of verification tests, the tests with the 2mm striker met the requirements at the low and high energy levels but not at the super high energy. For one plate, the 2mm striker showed somewhat higher average absorbed energies than those for the 8-mm striker at all three test temperatures. For the second plate and the LUS weld, however, the 2mm striker showed somewhat lower energies at both test temperatures. For the Russian forging steel and the HUS weld, tests were conducted over a range of temperatures with tests at one laboratory using the 8mm striker and tests at a second laboratory using the 2mm striker. Lateral expansion was measured for all specimens and the results are compared with the absorbed energy results. The overall results showed generally good agreement (within one standard deviation) in energy measurements by the two strikers. Load-time traces from the instrumented strikers were also compared and used to estimate shear fracture percentage. Four different formulas from the European Structural Integrity Society draft standard for instrumented Charpy test are compared and a new formula is proposed for estimation of percent shear from the force-time trace

  14. The production of UV Absorber amorphous cerium sulfide thin film

    Energy Technology Data Exchange (ETDEWEB)

    Kariper, İshak Afşin, E-mail: akariper@gmail.com [Faculty of Education, Erciyes University, Kayseri (Turkey)

    2017-10-15

    This study investigates the production of cerium sulfide (CeSx) amorphous thin films on substrates (commercial glass) by chemical bath deposition at different pH levels. The transmittance, absorption, optical band gap and refractive index of the films are measured by UV/VIS Spectrum. According to XRD analysis, the films show amorphous structure in the baths with pH: 1 to 5. It has been observed that the optical and structural properties of the films depend on pH value of the bath. The optical band gap (2.08 eV to 3.16 eV) of the films changes with the film thickness (23 nm to 1144 nm). We show that the refractive index has a positive relationship with the film thickness, where the values of 1.93, 1.45, 1.42, 2.60 and 1.39 are obtained for the former, and 34, 560, 509, 23 and 1144 nm (at 550 nm wavelength) for the latter. We compare the optical properties of amorphous and crystal form of CeSx thin films. We show that the optical band gaps of the amorphous CeS{sub x} are lower than that of crystal CeS{sub x} . (author)

  15. Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification.

    Science.gov (United States)

    Suriyapee, S; Pitaxtarnin, N; Oonsiri, S; Jumpangern, C; Israngkul Na Ayuthaya, I

    2008-01-01

    To investigate the optimal sensitometric curves of extended dose range (EDR2) radiographic film in terms of depth, field size, dose range and processing conditions for dynamic intensity modulated radiation therapy (IMRT) dosimetry verification with 6 MV X-ray beams. A Varian Clinac 23 EX linear accelerator with 6 MV X-ray beam was used to study the response of Kodak EDR2 film. Measurements were performed at depths of 5, 10 and 15 cm in MedTec virtual water phantom and with field sizes of 2x2, 3x3, 10x10 and 15x15 cm(2). Doses ranging from 20 to 450 cGy were used. The film was developed with the Kodak RP X-OMAT Model M6B automatic film processor. Film response was measured with the Vidar model VXR-16 scanner. Sensitometric curves were applied to the dose profiles measured with film at 5 cm in the virtual water phantom with field sizes of 2x2 and 10x10 cm(2) and compared with ion chamber data. Scanditronix/Wellhofer OmniPro(TM) IMRT software was used for the evaluation of the IMRT plan calculated by Eclipse treatment planning. Investigation of the reproducibility and accuracy of the film responses, which depend mainly on the film processor, was carried out by irradiating one film nine times with doses of 20 to 450 cGy. A maximum standard deviation of 4.9% was found which decreased to 1.9% for doses between 20 and 200 cGy. The sensitometric curves for various field sizes at fixed depth showed a maximum difference of 4.2% between 2x2 and 15x15 cm(2) at 5 cm depth with a dose of 450 cGy. The shallow depth tended to show a greater effect of field size responses than the deeper depths. The sensitometric curves for various depths at fixed field size showed slightly different film responses; the difference due to depth was within 1.8% for all field sizes studied. Both field size and depth effect were reduced when the doses were lower than 450 cGy. The difference was within 2.5% in the dose range from 20 to 300 cGy for all field sizes and depths studied. Dose profiles

  16. Development and utilization of liquid quartz light modulating film. Ekisho choko film no kaihatsu to riyo

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, M. (Ajinomoto Co. Inc., Tokyo (Japan))

    1992-03-01

    This paper introduces the polymer dispersed liquid crystal (PDLC) ACT'' sheet, a liquid quartz light modulating film, developed by the Ajinomoto Company in Japan. A mixture of liquid crystal and polymer precursor is sandwiched between polyethylene terephthalate films imparted with transparency conductor made of indium tin oxide (ITO), which is then polymerized by heating or irradiating ultraviolet rays to obtain a PDLC. The film has a thickness as thin as about 0.3 mm, and good processibility. The sheet uses light modulating elements functioning on scatter and permeation of light. Clarification was made on the voltage dependence of cloudiness, total light permeability, straight and parallel light permeability, the response, and the operating voltage. The system consumes small amount of power with a threshold value of about 35V, and is suitable to operate large areas when working on the utility power supply. An incident light having a high diffusion capability when the electric field is turned off exhibits a high clouding function. The system gives an excellent feel of colorlessness and transparency when the electric field is turned on. The performances in heat insulation, infrared reflection capability and noise resistance are expected to be compounded for a functional versatility. 4 refs., 6 figs., 2 tabs.

  17. MOBILITAS PEMBAWA MUATAN PADA OFET (ORGANIC FIELD EFFECT TRANSISTOR BERBASIS FILM TIPIS

    Directory of Open Access Journals (Sweden)

    Sujarwata -

    2014-06-01

    Full Text Available Abstrak __________________________________________________________________________________________ Tujuan penelitian ini adalah pembuatan dan karakterisasi pada OFET (Organic Field Effect Transistor berbasis film tipis dengan struktur bottom-contact. Pembuatan OFET dilakukan dengan cara pencucian substrat dengan etanol dalam ultrasonic cleaner, kemudian dilakukan deposisi elektroda source dan drain di atas substrat SiO2 dengan metode  penguapan hampa udara pada suhu ruang dan teknik lithography. Selanjutnya dilakukan deposisi film tipis CuPc diantara source (S dan drain (D sebagai panjang saluran (channel dan diakhiri dengan deposisi elektrode gate (G. Karakterisai OFET berbasis film tipis dilakukan dengan El-Kahfi 100, untuk menentukan karakteristik keluaran V-I. Hasil karakterisasi OFET dengan panjang channel (L 100 μm dan lebar (W 1 mm, mempunyai daerah aktif, yaitu: 2,80 V sampai dengan 3,42. Mobilitas pembawa muatan OFET untuk daerah saturasi, µ = 0,00182278 cm2 /Vs dan untuk daerah linier, µ = 0,000343818  cm2 /Vs   Abstract __________________________________________________________________________________________ The purpose of this research is to produce and characterize the OFET (Organic Field Effect Transistor based on thin film with bottom-contact structure. The OFET production consists of the substract wash by using ethanol in the ultrasonic cleaner, then electrode deposition of source and drain on the SiO2 substract by using vacuum evaporation in the room temperature and lithography technique.  Then, the deposition of thin film of CuPc between source (S and drain (D was done as the channel length and ended with electrode gate (G deposition. The OFET characterization  with channel length (L  100 μm and wide (W 1 mm  obtained the active area of 2,80 - 3,42 v. While the mobility of OFET charge carrier  obtained µ =  0,00182278 cm2 /Vs for the saturation area and µ = 0,000343818  cm2 /Vs for linier area.

  18. "One-sample concept" micro-combinatory for high throughput TEM of binary films.

    Science.gov (United States)

    Sáfrán, György

    2018-04-01

    Phases of thin films may remarkably differ from that of bulk. Unlike to the comprehensive data files of Binary Phase Diagrams [1] available for bulk, complete phase maps for thin binary layers do not exist. This is due to both the diverse metastable, non-equilibrium or instable phases feasible in thin films and the required volume of characterization work with analytical techniques like TEM, SAED and EDS. The aim of the present work was to develop a method that remarkably facilitates the TEM study of the diverse binary phases of thin films, or the creation of phase maps. A micro-combinatorial method was worked out that enables both preparation and study of a gradient two-component film within a single TEM specimen. For a demonstration of the technique thin Mn x Al 1- x binary samples with evolving concentration from x = 0 to x = 1 have been prepared so that the transition from pure Mn to pure Al covers a 1.5 mm long track within the 3 mm diameter TEM grid. The proposed method enables the preparation and study of thin combinatorial samples including all feasible phases as a function of composition or other deposition parameters. Contrary to known "combinatorial chemistry", in which a series of different samples are deposited in one run, and investigated, one at a time, the present micro-combinatorial method produces a single specimen condensing a complete library of a binary system that can be studied, efficiently, within a single TEM session. That provides extremely high throughput for TEM characterization of composition-dependent phases, exploration of new materials, or the construction of phase diagrams of binary films. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Tailoring surface properties of ArF resists thin films with functionally graded materials (FGM)

    Science.gov (United States)

    Takemoto, Ichiki; Ando, Nobuo; Edamatsu, Kunishige; Fuji, Yusuke; Kuwana, Koji; Hashimoto, Kazuhiko; Funase, Junji; Yokoyama, Hiroyuki

    2007-03-01

    Our recent research effort has been focused on new top coating-free 193nm immersion resists with regard to leaching of the resist components and lithographic performance. We have examined methacrylate-based resins that control the surface properties of ArF resists thin films by surface segregation behavior. For a better understanding of the surface properties of thin films, we prepared the six resins (Resin 1-6) that have three types fluorine containing monomers, a new monomer (Monomer A), Monomer B and Monomer C, respectively. We blended the base polymer (Resin 0) with Resin (1-6), respectively. We evaluated contact angles, surface properties and lithographic performances of the polymer blend resists. The static and receding contact angles of the resist that contains Resin (1-6) are greater than that of the base polymer (Resin 0) resist. The chemical composition of the surface of blend polymers was investigated with X-ray photoelectron spectroscopy (XPS). It was shown that there was significant segregation of the fluorine containing resins to the surface of the blend films. We analyzed Quantitative Structure-Property Relationships (QSPR) between the surface properties and the chemical composition of the surface of polymer blend resists. The addition of 10 wt% of the polymer (Resin 1-6) to the base polymer (Resin 0) did not influence the lithographic performance. Consequently, the surface properties of resist thin films can be tailored by the appropriate choice of fluorine containing polymer blends.

  20. Characterization of differences in calculated and actual measured skin doses to canine limbs during stereotactic radiosurgery using Gafchromic film

    Energy Technology Data Exchange (ETDEWEB)

    Walters, Jerri [Duke Energy, York, SC (United States); Colorado State University, Fort Collins, CO (United States); Ryan, Stewart [Animal Cancer Center, Colorado State University, Fort Collins, CO (United States); Harmon, Joseph F., E-mail: joseph_harmon@bshsi.org [Bon Secours Cancer Institute, Henrico, VA (United States)

    2012-07-01

    Accurate calculation of absorbed dose to the skin, especially the superficial and radiosensitive basal cell layer, is difficult for many reasons including, but not limited to, the build-up effect of megavoltage photons, tangential beam effects, mixed energy scatter from support devices, and dose interpolation caused by a finite resolution calculation matrix. Stereotactic body radiotherapy (SBRT) has been developed as an alternative limb salvage treatment option at Colorado State University Veterinary Teaching Hospital for dogs with extremity bone tumors. Optimal dose delivery to the tumor during SBRT treatment can be limited by uncertainty in skin dose calculation. The aim of this study was to characterize the difference between measured and calculated radiation dose by the Varian Eclipse (Varian Medical Systems, Palo Alto, CA) AAA treatment planning algorithm (for 1-mm, 2-mm, and 5-mm calculation voxel dimensions) as a function of distance from the skin surface. The study used Gafchromic EBT film (International Specialty Products, Wayne, NJ), FilmQA analysis software, a limb phantom constructed from plastic water Trade-Mark-Sign (fluke Biomedical, Everett, WA) and a canine cadaver forelimb. The limb phantom was exposed to 6-MV treatments consisting of a single-beam, a pair of parallel opposed beams, and a 7-beam coplanar treatment plan. The canine forelimb was exposed to the 7-beam coplanar plan. Radiation dose to the forelimb skin at the surface and at depths of 1.65 mm and 1.35 mm below the skin surface were also measured with the Gafchromic film. The calculation algorithm estimated the dose well at depths beyond buildup for all calculation voxel sizes. The calculation algorithm underestimated the dose in portions of the buildup region of tissue for all comparisons, with the most significant differences observed in the 5-mm calculation voxel and the least difference in the 1-mm voxel. Results indicate a significant difference between measured and calculated data