WorldWideScience

Sample records for video quality measurement

  1. Video Measurements: Quantity or Quality

    Science.gov (United States)

    Zajkov, Oliver; Mitrevski, Boce

    2012-01-01

    Students have problems with understanding, using and interpreting graphs. In order to improve the students' skills for working with graphs, we propose Manual Video Measurement (MVM). In this paper, the MVM method is explained and its accuracy is tested. The comparison with the standardized video data software shows that its accuracy is comparable…

  2. Video quality measure for mobile IPTV service

    Science.gov (United States)

    Kim, Wonjun; Kim, Changick

    2008-08-01

    Mobile IPTV is a multimedia service based on wireless networks with interactivity and mobility. Under mobile IPTV scenarios, people can watch various contents whenever they want and even deliver their request to service providers through the network. However, the frequent change of the wireless channel bandwidth may hinder the quality of service. In this paper, we propose an objective video quality measure (VQM) for mobile IPTV services, which is focused on the jitter measurement. Jitter is the result of frame repetition during the delay and one of the most severe impairments in the video transmission via mobile channels. We first employ YUV color space to compute the duration and occurrences of jitter and the motion activity. Then the VQM is modeled by the combination of these three factors and the result of subjective assessment. Since the proposed VQM is based on no-reference (NR) model, it can be applied for real-time applications. Experimental results show that the proposed VQM highly correlates to subjective evaluation.

  3. Quality and noise measurements in mobile phone video capture

    Science.gov (United States)

    Petrescu, Doina; Pincenti, John

    2011-02-01

    The quality of videos captured with mobile phones has become increasingly important particularly since resolutions and formats have reached a level that rivals the capabilities available in the digital camcorder market, and since many mobile phones now allow direct playback on large HDTVs. The video quality is determined by the combined quality of the individual parts of the imaging system including the image sensor, the digital color processing, and the video compression, each of which has been studied independently. In this work, we study the combined effect of these elements on the overall video quality. We do this by evaluating the capture under various lighting, color processing, and video compression conditions. First, we measure full reference quality metrics between encoder input and the reconstructed sequence, where the encoder input changes with light and color processing modifications. Second, we introduce a system model which includes all elements that affect video quality, including a low light additive noise model, ISP color processing, as well as the video encoder. Our experiments show that in low light conditions and for certain choices of color processing the system level visual quality may not improve when the encoder becomes more capable or the compression ratio is reduced.

  4. Objective video quality measure for application to tele-echocardiography.

    Science.gov (United States)

    Moore, Peter Thomas; O'Hare, Neil; Walsh, Kevin P; Ward, Neil; Conlon, Niamh

    2008-08-01

    Real-time tele-echocardiography is widely used to remotely diagnose or exclude congenital heart defects. Cost effective technical implementation is realised using low-bandwidth transmission systems and lossy compression (videoconferencing) schemes. In our study, DICOM video sequences were converted to common multimedia formats, which were then, compressed using three lossy compression algorithms. We then applied a digital (multimedia) video quality metric (VQM) to determine objectively a value for degradation due to compression. Three levels of compression were simulated by varying system bandwidth and compared to a subjective assessment of video clip quality by three paediatric cardiologists with more than 5 years of experience.

  5. Subjective video quality comparison of HDTV monitors

    Science.gov (United States)

    Seo, G.; Lim, C.; Lee, S.; Lee, C.

    2009-01-01

    HDTV broadcasting services have become widely available. Furthermore, in the upcoming IPTV services, HDTV services are important and quality monitoring becomes an issue, particularly in IPTV services. Consequently, there have been great efforts to develop video quality measurement methods for HDTV. On the other hand, most HDTV programs will be watched on digital TV monitors which include LCD and PDP TV monitors. In general, the LCD and PDP TV monitors have different color characteristics and response times. Furthermore, most commercial TV monitors include post-processing to improve video quality. In this paper, we compare subjective video quality of some commercial HD TV monitors to investigate the impact of monitor type on perceptual video quality. We used the ACR method as a subjective testing method. Experimental results show that the correlation coefficients among the HDTV monitors are reasonable high. However, for some video sequences and impairments, some differences in subjective scores were observed.

  6. Video Quality Prediction over Wireless 4G

    KAUST Repository

    Lau, Chun Pong

    2013-04-14

    In this paper, we study the problem of video quality prediction over the wireless 4G network. Video transmission data is collected from a real 4G SCM testbed for investigating factors that affect video quality. After feature transformation and selection on video and network parameters, video quality is predicted by solving as regression problem. Experimental results show that the dominated factor on video quality is the channel attenuation and video quality can be well estimated by our models with small errors.

  7. Video Quality Prediction over Wireless 4G

    KAUST Repository

    Lau, Chun Pong; Zhang, Xiangliang; Shihada, Basem

    2013-01-01

    In this paper, we study the problem of video quality prediction over the wireless 4G network. Video transmission data is collected from a real 4G SCM testbed for investigating factors that affect video quality. After feature transformation and selection on video and network parameters, video quality is predicted by solving as regression problem. Experimental results show that the dominated factor on video quality is the channel attenuation and video quality can be well estimated by our models with small errors.

  8. Real-time video quality monitoring

    Science.gov (United States)

    Liu, Tao; Narvekar, Niranjan; Wang, Beibei; Ding, Ran; Zou, Dekun; Cash, Glenn; Bhagavathy, Sitaram; Bloom, Jeffrey

    2011-12-01

    The ITU-T Recommendation G.1070 is a standardized opinion model for video telephony applications that uses video bitrate, frame rate, and packet-loss rate to measure the video quality. However, this model was original designed as an offline quality planning tool. It cannot be directly used for quality monitoring since the above three input parameters are not readily available within a network or at the decoder. And there is a great room for the performance improvement of this quality metric. In this article, we present a real-time video quality monitoring solution based on this Recommendation. We first propose a scheme to efficiently estimate the three parameters from video bitstreams, so that it can be used as a real-time video quality monitoring tool. Furthermore, an enhanced algorithm based on the G.1070 model that provides more accurate quality prediction is proposed. Finally, to use this metric in real-world applications, we present an example emerging application of real-time quality measurement to the management of transmitted videos, especially those delivered to mobile devices.

  9. Identifying Measures Used for Assessing Quality of YouTube Videos with Patient Health Information: A Review of Current Literature.

    Science.gov (United States)

    Gabarron, Elia; Fernandez-Luque, Luis; Armayones, Manuel; Lau, Annie Ys

    2013-02-28

    Recent publications on YouTube have advocated its potential for patient education. However, a reliable description of what could be considered quality information for patient education on YouTube is missing. To identify topics associated with the concept of quality information for patient education on YouTube in the scientific literature. A literature review was performed in MEDLINE, ISI Web of Knowledge, Scopus, and PsychINFO. Abstract selection was first conducted by two independent reviewers; discrepancies were discussed in a second abstract review with two additional independent reviewers. Full text of selected papers were analyzed looking for concepts, definitions, and topics used by its authors that focused on the quality of information on YouTube for patient education. In total, 456 abstracts were extracted and 13 papers meeting eligibility criteria were analyzed. Concepts identified related to quality of information for patient education are categorized as expert-driven, popularity-driven, or heuristic-driven measures. These include (in descending order): (1) quality of content in 10/13 (77%), (2) view count in 9/13 (69%), (3) health professional opinion in 8/13 (62%), (4) adequate length or duration in 6/13 (46%), (5) public ratings in 5/13 (39%), (6) adequate title, tags, and description in 5/13 (39%), (7) good description or a comprehensive narrative in 4/13 (31%), (8) evidence-based practices included in video in 4/13 (31%), (9) suitability as a teaching tool in 4/13 (31%), (10) technical quality in 4/13 (31%), (11) credentials provided in video in 4/13 (31%), (12) enough amount of content to identify its objective in 3/13 (23%), and (13) viewership share in 2/13 (15%). Our review confirms that the current topics linked to quality of information for patient education on YouTube are unclear and not standardized. Although expert-driven, popularity-driven, or heuristic-driven measures are used as proxies to estimate the quality of video information

  10. A quality assurance study on the accuracy of measuring physical function under current conditions for use of clinical video telehealth.

    Science.gov (United States)

    Hoenig, Helen; Tate, Latoya; Dumbleton, Sarina; Montgomery, Christy; Morgan, Michelle; Landerman, Lawrence R; Caves, Kevin

    2013-05-01

    To determine whether conditions for use of clinical video telehealth technology might affect the accuracy of measures of physical function. Repeated measures. Veterans Administration Medical Center. Three healthy adult volunteers for a sample size of n=30 independent trials for each of 3 physical function tasks. None. Three tasks capturing differing aspects of physical function: fine-motor coordination (number of finger taps in 30s), gross-motor coordination (number of gait deviations in 10ft [3.05m]), and clinical spatial relations (identifying the proper height for a cane randomly preset ±0-2in [5.1cm] from optimal), with performance simultaneously assessed in person and video recorded. Interrater reliability and criterion validity were determined for the measurement of these 3 tasks scored according to 5 methods: (1) in person (community standard), (2) slow motion review of the video recording (criterion standard), and (3-5) full speed review at 3 Internet bandwidths (64kps, 384kps, and 768kps). Fine-motor coordination-Interrater reliability was variable (r=.43-.81) and criterion validity was poor at 64kps and 384kps, but both were acceptable at 768kps (reliability r=.74, validity β=.81). Gross-motor coordination-Interreliability was variable (range r=.53-.75) and criterion validity was poor at all bandwidths (β=.28-.47). Motionless spatial relations-Excellent reliability (r=.92-.97) and good criterion validity (β=.84-.89) at all the tested bandwidths. Internet bandwidth had differing effects on measurement validity and reliability for the fine-motor task, the gross-motor task, and spatial relations, with results for some tasks at some transmission speeds well below acceptable quality standards and community standards. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. Attention modeling for video quality assessment

    DEFF Research Database (Denmark)

    You, Junyong; Korhonen, Jari; Perkis, Andrew

    2010-01-01

    averaged spatiotemporal pooling. The local quality is derived from visual attention modeling and quality variations over frames. Saliency, motion, and contrast information are taken into account in modeling visual attention, which is then integrated into IQMs to calculate the local quality of a video frame...... average between the global quality and the local quality. Experimental results demonstrate that the combination of the global quality and local quality outperforms both sole global quality and local quality, as well as other quality models, in video quality assessment. In addition, the proposed video...... quality modeling algorithm can improve the performance of image quality metrics on video quality assessment compared to the normal averaged spatiotemporal pooling scheme....

  12. No Reference Video-Quality-Assessment Model for Monitoring Video Quality of IPTV Services

    Science.gov (United States)

    Yamagishi, Kazuhisa; Okamoto, Jun; Hayashi, Takanori; Takahashi, Akira

    Service providers should monitor the quality of experience of a communication service in real time to confirm its status. To do this, we previously proposed a packet-layer model that can be used for monitoring the average video quality of typical Internet protocol television content using parameters derived from transmitted packet headers. However, it is difficult to monitor the video quality per user using the average video quality because video quality depends on the video content. To accurately monitor the video quality per user, a model that can be used for estimating the video quality per video content rather than the average video quality should be developed. Therefore, to take into account the impact of video content on video quality, we propose a model that calculates the difference in video quality between the video quality of the estimation-target video and the average video quality estimated using a packet-layer model. We first conducted extensive subjective quality assessments for different codecs and video sequences. We then model their characteristics based on parameters related to compression and packet loss. Finally, we verify the performance of the proposed model by applying it to unknown data sets different from the training data sets used for developing the model.

  13. Quality of Experience Assessment of Video Quality in Social Clouds

    Directory of Open Access Journals (Sweden)

    Asif Ali Laghari

    2017-01-01

    Full Text Available Video sharing on social clouds is popular among the users around the world. High-Definition (HD videos have big file size so the storing in cloud storage and streaming of videos with high quality from cloud to the client are a big problem for service providers. Social clouds compress the videos to save storage and stream over slow networks to provide quality of service (QoS. Compression of video decreases the quality compared to original video and parameters are changed during the online play as well as after download. Degradation of video quality due to compression decreases the quality of experience (QoE level of end users. To assess the QoE of video compression, we conducted subjective (QoE experiments by uploading, sharing, and playing videos from social clouds. Three popular social clouds, Facebook, Tumblr, and Twitter, were selected to upload and play videos online for users. The QoE was recorded by using questionnaire given to users to provide their experience about the video quality they perceive. Results show that Facebook and Twitter compressed HD videos more as compared to other clouds. However, Facebook gives a better quality of compressed videos compared to Twitter. Therefore, users assigned low ratings for Twitter for online video quality compared to Tumblr that provided high-quality online play of videos with less compression.

  14. Quality-Aware Estimation of Facial Landmarks in Video Sequences

    DEFF Research Database (Denmark)

    Haque, Mohammad Ahsanul; Nasrollahi, Kamal; Moeslund, Thomas B.

    2015-01-01

    Face alignment in video is a primitive step for facial image analysis. The accuracy of the alignment greatly depends on the quality of the face image in the video frames and low quality faces are proven to cause erroneous alignment. Thus, this paper proposes a system for quality aware face...... for facial landmark detection. If the face quality is low the proposed system corrects the facial landmarks that are detected by SDM. Depending upon the face velocity in consecutive video frames and face quality measure, two algorithms are proposed for correction of landmarks in low quality faces by using...

  15. Blind prediction of natural video quality.

    Science.gov (United States)

    Saad, Michele A; Bovik, Alan C; Charrier, Christophe

    2014-03-01

    We propose a blind (no reference or NR) video quality evaluation model that is nondistortion specific. The approach relies on a spatio-temporal model of video scenes in the discrete cosine transform domain, and on a model that characterizes the type of motion occurring in the scenes, to predict video quality. We use the models to define video statistics and perceptual features that are the basis of a video quality assessment (VQA) algorithm that does not require the presence of a pristine video to compare against in order to predict a perceptual quality score. The contributions of this paper are threefold. 1) We propose a spatio-temporal natural scene statistics (NSS) model for videos. 2) We propose a motion model that quantifies motion coherency in video scenes. 3) We show that the proposed NSS and motion coherency models are appropriate for quality assessment of videos, and we utilize them to design a blind VQA algorithm that correlates highly with human judgments of quality. The proposed algorithm, called video BLIINDS, is tested on the LIVE VQA database and on the EPFL-PoliMi video database and shown to perform close to the level of top performing reduced and full reference VQA algorithms.

  16. Creep Measurement Video Extensometer

    Science.gov (United States)

    Jaster, Mark; Vickerman, Mary; Padula, Santo, II; Juhas, John

    2011-01-01

    Understanding material behavior under load is critical to the efficient and accurate design of advanced aircraft and spacecraft. Technologies such as the one disclosed here allow accurate creep measurements to be taken automatically, reducing error. The goal was to develop a non-contact, automated system capable of capturing images that could subsequently be processed to obtain the strain characteristics of these materials during deformation, while maintaining adequate resolution to capture the true deformation response of the material. The measurement system comprises a high-resolution digital camera, computer, and software that work collectively to interpret the image.

  17. No-Reference Video Quality Assessment using Codec Analysis

    DEFF Research Database (Denmark)

    Søgaard, Jacob; Forchhammer, Søren; Korhonen, Jari

    2015-01-01

    types of videos, estimating the level of quantization used in the I-frames, and exploiting this information to assess the video quality. In order to do this for H.264/AVC, the distribution of the DCT-coefficients after intra-prediction and deblocking are modeled. To obtain VQA features for H.264/AVC, we......A no-reference video quality assessment (VQA) method is presented for videos distorted by H.264/AVC and MPEG-2. The assessment is performed without access to the bit-stream. Instead we analyze and estimate coefficients based on decoded pixels. The approach involves distinguishing between the two...... propose a novel estimation method of the quantization in H.264/AVC videos without bitstream access, which can also be used for Peak Signalto-Noise Ratio (PSNR) estimation. The results from the MPEG-2 and H.264/AVC analysis are mapped to a perceptual measure of video quality by Support Vector Regression...

  18. Delivering Diagnostic Quality Video over Mobile Wireless Networks for Telemedicine

    Directory of Open Access Journals (Sweden)

    Sira P. Rao

    2009-01-01

    Full Text Available In real-time remote diagnosis of emergency medical events, mobility can be enabled by wireless video communications. However, clinical use of this potential advance will depend on definitive and compelling demonstrations of the reliability of diagnostic quality video. Because the medical domain has its own fidelity criteria, it is important to incorporate diagnostic video quality criteria into any video compression system design. To this end, we used flexible algorithms for region-of-interest (ROI video compression and obtained feedback from medical experts to develop criteria for diagnostically lossless (DL quality. The design of the system occurred in three steps-measurement of bit rate at which DL quality is achieved through evaluation of videos by medical experts, incorporation of that information into a flexible video encoder through the notion of encoder states, and an encoder state update option based on a built-in quality criterion. Medical experts then evaluated our system for the diagnostic quality of the video, allowing us to verify that it is possible to realize DL quality in the ROI at practical communication data transfer rates, enabling mobile medical assessment over bit-rate limited wireless channels. This work lays the scientific foundation for additional validation through prototyped technology, field testing, and clinical trials.

  19. Perceptual video quality assessment in H.264 video coding standard using objective modeling.

    Science.gov (United States)

    Karthikeyan, Ramasamy; Sainarayanan, Gopalakrishnan; Deepa, Subramaniam Nachimuthu

    2014-01-01

    Since usage of digital video is wide spread nowadays, quality considerations have become essential, and industry demand for video quality measurement is rising. This proposal provides a method of perceptual quality assessment in H.264 standard encoder using objective modeling. For this purpose, quality impairments are calculated and a model is developed to compute the perceptual video quality metric based on no reference method. Because of the shuttle difference between the original video and the encoded video the quality of the encoded picture gets degraded, this quality difference is introduced by the encoding process like Intra and Inter prediction. The proposed model takes into account of the artifacts introduced by these spatial and temporal activities in the hybrid block based coding methods and an objective modeling of these artifacts into subjective quality estimation is proposed. The proposed model calculates the objective quality metric using subjective impairments; blockiness, blur and jerkiness compared to the existing bitrate only calculation defined in the ITU G 1070 model. The accuracy of the proposed perceptual video quality metrics is compared against popular full reference objective methods as defined by VQEG.

  20. Perceived Quality of Full HD Video - Subjective Quality Assessment

    Directory of Open Access Journals (Sweden)

    Juraj Bienik

    2016-01-01

    Full Text Available In recent years, an interest in multimedia services has become a global trend and this trend is still rising. The video quality is a very significant part from the bundle of multimedia services, which leads to a requirement for quality assessment in the video domain. Video quality of a streamed video across IP networks is generally influenced by two factors “transmission link imperfection and efficiency of compression standards. This paper deals with subjective video quality assessment and the impact of the compression standards H.264, H.265 and VP9 on perceived video quality of these compression standards. The evaluation is done for four full HD sequences, the difference of scenes is in the content“ distinction is based on Spatial (SI and Temporal (TI Index of test sequences. Finally, experimental results follow up to 30% bitrate reducing of H.265 and VP9 compared with the reference H.264.

  1. Video Quality Prediction Models Based on Video Content Dynamics for H.264 Video over UMTS Networks

    Directory of Open Access Journals (Sweden)

    Asiya Khan

    2010-01-01

    Full Text Available The aim of this paper is to present video quality prediction models for objective non-intrusive, prediction of H.264 encoded video for all content types combining parameters both in the physical and application layer over Universal Mobile Telecommunication Systems (UMTS networks. In order to characterize the Quality of Service (QoS level, a learning model based on Adaptive Neural Fuzzy Inference System (ANFIS and a second model based on non-linear regression analysis is proposed to predict the video quality in terms of the Mean Opinion Score (MOS. The objective of the paper is two-fold. First, to find the impact of QoS parameters on end-to-end video quality for H.264 encoded video. Second, to develop learning models based on ANFIS and non-linear regression analysis to predict video quality over UMTS networks by considering the impact of radio link loss models. The loss models considered are 2-state Markov models. Both the models are trained with a combination of physical and application layer parameters and validated with unseen dataset. Preliminary results show that good prediction accuracy was obtained from both the models. The work should help in the development of a reference-free video prediction model and QoS control methods for video over UMTS networks.

  2. Adaptive testing for video quality assessment

    NARCIS (Netherlands)

    Menkovski, V.; Exarchakos, G.; Liotta, A.; Damásio, M.J.; Cardoso, G.; Quico, C.; Geerts, D.

    2011-01-01

    Optimizing the Quality of Experience and avoiding under or over provisioning in video delivery services requires understanding of how different resources affect the perceived quality. The utility of resources, such as bit-rate, is directly calculated by proportioningthe improvement in quality over

  3. Range-Measuring Video Sensors

    Science.gov (United States)

    Howard, Richard T.; Briscoe, Jeri M.; Corder, Eric L.; Broderick, David

    2006-01-01

    Optoelectronic sensors of a proposed type would perform the functions of both electronic cameras and triangulation- type laser range finders. That is to say, these sensors would both (1) generate ordinary video or snapshot digital images and (2) measure the distances to selected spots in the images. These sensors would be well suited to use on robots that are required to measure distances to targets in their work spaces. In addition, these sensors could be used for all the purposes for which electronic cameras have been used heretofore. The simplest sensor of this type, illustrated schematically in the upper part of the figure, would include a laser, an electronic camera (either video or snapshot), a frame-grabber/image-capturing circuit, an image-data-storage memory circuit, and an image-data processor. There would be no moving parts. The laser would be positioned at a lateral distance d to one side of the camera and would be aimed parallel to the optical axis of the camera. When the range of a target in the field of view of the camera was required, the laser would be turned on and an image of the target would be stored and preprocessed to locate the angle (a) between the optical axis and the line of sight to the centroid of the laser spot.

  4. Measuring Quality

    DEFF Research Database (Denmark)

    Næsby, Torben

    local differences in the quality of day care facilities in Denmark (Nordahl et al, 2012; Hansen et al, 2016) and also that we in fact have little knowledge of whether the desired politically determined targets are being met or not and what the quality is really like. In order to measure the quality......The Danish Day Care Facilities Act (2015), which provides the curriculum on which day care education is based, does not stipulate very clearly what children should learn and therefore how educational processes in preschools should be organised. This means that we must accept that there are large...... of preschool in Denmark a new research project using the ECERS 3 instrument has been launched. This could capture quality from a global quality standard’s perspective, building the basis for a further investigation of practice in Danish early childhood provisions and centers in a more narrow approach...

  5. Quality of pharmaceutical care at the pharmacy counter : Patients’ experiences versus video observation

    NARCIS (Netherlands)

    Koster, Ellen S.; Blom, Lyda; Overbeeke, Marloes R.; Philbert, Daphne; Vervloet, Marcia; Koopman, Laura; van Dijk, Liset

    2016-01-01

    Introduction: Consumer Quality Index questionnaires are used to assess quality of care from patients’ experiences. Objective: To provide insight into the agreement about quality of pharmaceutical care, measured both by a patient questionnaire and video observations. Methods: Pharmaceutical

  6. Quality of pharmaceutical care at the pharmacy counter: patients’ experiences versus video observation.

    NARCIS (Netherlands)

    Koster, E.S.; Blom, L.; Overbeeke, M.R.; Philbert, D.; Vervloet, M.; Koopman, L.; Dijk, L. van

    2016-01-01

    Introduction: Consumer Quality Index questionnaires are used to assess quality of care from patients’ experiences. Objective: To provide insight into the agreement about quality of pharmaceutical care, measured both by a patient questionnaire and video observations. Methods: Pharmaceutical

  7. Towards Video Quality Metrics Based on Colour Fractal Geometry

    Directory of Open Access Journals (Sweden)

    Richard Noël

    2010-01-01

    Full Text Available Vision is a complex process that integrates multiple aspects of an image: spatial frequencies, topology and colour. Unfortunately, so far, all these elements were independently took into consideration for the development of image and video quality metrics, therefore we propose an approach that blends together all of them. Our approach allows for the analysis of the complexity of colour images in the RGB colour space, based on the probabilistic algorithm for calculating the fractal dimension and lacunarity. Given that all the existing fractal approaches are defined only for gray-scale images, we extend them to the colour domain. We show how these two colour fractal features capture the multiple aspects that characterize the degradation of the video signal, based on the hypothesis that the quality degradation perceived by the user is directly proportional to the modification of the fractal complexity. We claim that the two colour fractal measures can objectively assess the quality of the video signal and they can be used as metrics for the user-perceived video quality degradation and we validated them through experimental results obtained for an MPEG-4 video streaming application; finally, the results are compared against the ones given by unanimously-accepted metrics and subjective tests.

  8. Quality metric for spherical panoramic video

    Science.gov (United States)

    Zakharchenko, Vladyslav; Choi, Kwang Pyo; Park, Jeong Hoon

    2016-09-01

    Virtual reality (VR)/ augmented reality (AR) applications allow users to view artificial content of a surrounding space simulating presence effect with a help of special applications or devices. Synthetic contents production is well known process form computer graphics domain and pipeline has been already fixed in the industry. However emerging multimedia formats for immersive entertainment applications such as free-viewpoint television (FTV) or spherical panoramic video require different approaches in content management and quality assessment. The international standardization on FTV has been promoted by MPEG. This paper is dedicated to discussion of immersive media distribution format and quality estimation process. Accuracy and reliability of the proposed objective quality estimation method had been verified with spherical panoramic images demonstrating good correlation results with subjective quality estimation held by a group of experts.

  9. Perceptual tools for quality-aware video networks

    Science.gov (United States)

    Bovik, A. C.

    2014-01-01

    Monitoring and controlling the quality of the viewing experience of videos transmitted over increasingly congested networks (especially wireless networks) is a pressing problem owing to rapid advances in video-centric mobile communication and display devices that are straining the capacity of the network infrastructure. New developments in automatic perceptual video quality models offer tools that have the potential to be used to perceptually optimize wireless video, leading to more efficient video data delivery and better received quality. In this talk I will review key perceptual principles that are, or could be used to create effective video quality prediction models, and leading quality prediction models that utilize these principles. The goal is to be able to monitor and perceptually optimize video networks by making them "quality-aware."

  10. Measurement study of multi-party video conferencing

    NARCIS (Netherlands)

    Lu, Y.; Zhao, Y.; Kuipers, F.A.; Van Mieghem, P.

    2010-01-01

    More and more free multi-party video conferencing applications are readily available over the Internet and both Server-to-Client (S/C) or Peer-to-Peer (P2P) technologies are used. Investigating their mechanisms, analyzing their system performance, and measuring their quality are important objectives

  11. Video quality pooling adaptive to perceptual distortion severity.

    Science.gov (United States)

    Park, Jincheol; Seshadrinathan, Kalpana; Lee, Sanghoon; Bovik, Alan Conrad

    2013-02-01

    It is generally recognized that severe video distortions that are transient in space and/or time have a large effect on overall perceived video quality. In order to understand this phenomena, we study the distribution of spatio-temporally local quality scores obtained from several video quality assessment (VQA) algorithms on videos suffering from compression and lossy transmission over communication channels. We propose a content adaptive spatial and temporal pooling strategy based on the observed distribution. Our method adaptively emphasizes "worst" scores along both the spatial and temporal dimensions of a video sequence and also considers the perceptual effect of large-area cohesive motion flow such as egomotion. We demonstrate the efficacy of the method by testing it using three different VQA algorithms on the LIVE Video Quality database and the EPFL-PoliMI video quality database.

  12. Heartbeat Rate Measurement from Facial Video

    DEFF Research Database (Denmark)

    Haque, Mohammad Ahsanul; Irani, Ramin; Nasrollahi, Kamal

    2016-01-01

    Heartbeat Rate (HR) reveals a person’s health condition. This paper presents an effective system for measuring HR from facial videos acquired in a more realistic environment than the testing environment of current systems. The proposed method utilizes a facial feature point tracking method...... by combining a ‘Good feature to track’ and a ‘Supervised descent method’ in order to overcome the limitations of currently available facial video based HR measuring systems. Such limitations include, e.g., unrealistic restriction of the subject’s movement and artificial lighting during data capture. A face...

  13. Video processing for human perceptual visual quality-oriented video coding.

    Science.gov (United States)

    Oh, Hyungsuk; Kim, Wonha

    2013-04-01

    We have developed a video processing method that achieves human perceptual visual quality-oriented video coding. The patterns of moving objects are modeled by considering the limited human capacity for spatial-temporal resolution and the visual sensory memory together, and an online moving pattern classifier is devised by using the Hedge algorithm. The moving pattern classifier is embedded in the existing visual saliency with the purpose of providing a human perceptual video quality saliency model. In order to apply the developed saliency model to video coding, the conventional foveation filtering method is extended. The proposed foveation filter can smooth and enhance the video signals locally, in conformance with the developed saliency model, without causing any artifacts. The performance evaluation results confirm that the proposed video processing method shows reliable improvements in the perceptual quality for various sequences and at various bandwidths, compared to existing saliency-based video coding methods.

  14. Deep learning for quality assessment in live video streaming

    NARCIS (Netherlands)

    Torres Vega, M.; Mocanu, D.C.; Famaey, J.; Stavrou, S.; Liotta, A.

    Video content providers put stringent requirements on the quality assessment methods realized on their services. They need to be accurate, real-time, adaptable to new content, and scalable as the video set grows. In this letter, we introduce a novel automated and computationally efficient video

  15. Rate control scheme for consistent video quality in scalable video codec.

    Science.gov (United States)

    Seo, Chan-Won; Han, Jong-Ki; Nguyen, Truong Q

    2011-08-01

    Multimedia data delivered to mobile devices over wireless channels or the Internet are complicated by bandwidth fluctuation and the variety of mobile devices. Scalable video coding has been developed as an extension of H.264/AVC to solve this problem. Since scalable video codec provides various scalabilities to adapt the bitstream for the channel conditions and terminal types, scalable codec is one of the useful codecs for wired or wireless multimedia communication systems, such as IPTV and streaming services. In such scalable multimedia communication systems, video quality fluctuation degrades the visual perception significantly. It is important to efficiently use the target bits in order to maintain a consistent video quality or achieve a small distortion variation throughout the whole video sequence. The scheme proposed in this paper provides a useful function to control video quality in applications supporting scalability, whereas conventional schemes have been proposed to control video quality in the H.264 and MPEG-4 systems. The proposed algorithm decides the quantization parameter of the enhancement layer to maintain a consistent video quality throughout the entire sequence. The video quality of the enhancement layer is controlled based on a closed-form formula which utilizes the residual data and quantization error of the base layer. The simulation results show that the proposed algorithm controls the frame quality of the enhancement layer in a simple operation, where the parameter decision algorithm is applied to each frame.

  16. No-Reference Video Quality Assessment using MPEG Analysis

    DEFF Research Database (Denmark)

    Søgaard, Jacob; Forchhammer, Søren; Korhonen, Jari

    2013-01-01

    We present a method for No-Reference (NR) Video Quality Assessment (VQA) for decoded video without access to the bitstream. This is achieved by extracting and pooling features from a NR image quality assessment method used frame by frame. We also present methods to identify the video coding...... and estimate the video coding parameters for MPEG-2 and H.264/AVC which can be used to improve the VQA. The analysis differs from most other video coding analysis methods since it is without access to the bitstream. The results show that our proposed method is competitive with other recent NR VQA methods...

  17. Effective Quality-of-Service Renegotiating Schemes for Streaming Video

    Directory of Open Access Journals (Sweden)

    Song Hwangjun

    2004-01-01

    Full Text Available This paper presents effective quality-of-service renegotiating schemes for streaming video. The conventional network supporting quality of service generally allows a negotiation at a call setup. However, it is not efficient for the video application since the compressed video traffic is statistically nonstationary. Thus, we consider the network supporting quality-of-service renegotiations during the data transmission and study effective quality-of-service renegotiating schemes for streaming video. The token bucket model, whose parameters are token filling rate and token bucket size, is adopted for the video traffic model. The renegotiating time instants and the parameters are determined by analyzing the statistical information of compressed video traffic. In this paper, two renegotiating approaches, that is, fixed renegotiating interval case and variable renegotiating interval case, are examined. Finally, the experimental results are provided to show the performance of the proposed schemes.

  18. Video integrated measurement system. [Diagnostic display devices

    Energy Technology Data Exchange (ETDEWEB)

    Spector, B.; Eilbert, L.; Finando, S.; Fukuda, F.

    1982-06-01

    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  19. Offset Trace-Based Video Quality Evaluation Network Transport

    DEFF Research Database (Denmark)

    Seeling, P.; Reisslein, M.; Fitzek, Frank

    2006-01-01

    Video traces contain information about encoded video frames, such as frame sizes and qualities, and provide a convenient method to conduct multimedia networking research. Although wiedely used in networking research, these traces do not allow to determine the video qaulityin an accurate manner...... after networking transport that includes losses and delays. In this work, we provide (i) an overview of frame dependencies that have to be taken into consideration when working with video traces, (ii) an algorithmic approach to combine traditional video traces and offset distortion traces to determine...... the video quality or distortion after lossy network transport, (iii) offset distortion and quality characteristics and (iv) the offset distortion trace format and tools to create offset distortion traces....

  20. Research on quality metrics of wireless adaptive video streaming

    Science.gov (United States)

    Li, Xuefei

    2018-04-01

    With the development of wireless networks and intelligent terminals, video traffic has increased dramatically. Adaptive video streaming has become one of the most promising video transmission technologies. For this type of service, a good QoS (Quality of Service) of wireless network does not always guarantee that all customers have good experience. Thus, new quality metrics have been widely studies recently. Taking this into account, the objective of this paper is to investigate the quality metrics of wireless adaptive video streaming. In this paper, a wireless video streaming simulation platform with DASH mechanism and multi-rate video generator is established. Based on this platform, PSNR model, SSIM model and Quality Level model are implemented. Quality Level Model considers the QoE (Quality of Experience) factors such as image quality, stalling and switching frequency while PSNR Model and SSIM Model mainly consider the quality of the video. To evaluate the performance of these QoE models, three performance metrics (SROCC, PLCC and RMSE) which are used to make a comparison of subjective and predicted MOS (Mean Opinion Score) are calculated. From these performance metrics, the monotonicity, linearity and accuracy of these quality metrics can be observed.

  1. Crowdsourcing based subjective quality assessment of adaptive video streaming

    DEFF Research Database (Denmark)

    Shahid, M.; Søgaard, Jacob; Pokhrel, J.

    2014-01-01

    In order to cater for user’s quality of experience (QoE) re- quirements, HTTP adaptive streaming (HAS) based solutions of video services have become popular recently. User QoE feedback can be instrumental in improving the capabilities of such services. Perceptual quality experiments that involve...... humans are considered to be the most valid method of the as- sessment of QoE. Besides lab-based subjective experiments, crowdsourcing based subjective assessment of video quality is gaining popularity as an alternative method. This paper presents insights into a study that investigates perceptual pref......- erences of various adaptive video streaming scenarios through crowdsourcing based subjective quality assessment....

  2. Subjective Video Quality Assessment in H.264/AVC Video Coding Standard

    Directory of Open Access Journals (Sweden)

    Z. Miličević

    2012-11-01

    Full Text Available This paper seeks to provide an approach for subjective video quality assessment in the H.264/AVC standard. For this purpose a special software program for the subjective assessment of quality of all the tested video sequences is developed. It was developed in accordance with recommendation ITU-T P.910, since it is suitable for the testing of multimedia applications. The obtained results show that in the proposed selective intra prediction and optimized inter prediction algorithm there is a small difference in picture quality (signal-to-noise ratio between decoded original and modified video sequences.

  3. PSQM-based RR and NR video quality metrics

    Science.gov (United States)

    Lu, Zhongkang; Lin, Weisi; Ong, Eeping; Yang, Xiaokang; Yao, Susu

    2003-06-01

    This paper presents a new and general concept, PQSM (Perceptual Quality Significance Map), to be used in measuring the visual distortion. It makes use of the selectivity characteristic of HVS (Human Visual System) that it pays more attention to certain area/regions of visual signal due to one or more of the following factors: salient features in image/video, cues from domain knowledge, and association of other media (e.g., speech or audio). PQSM is an array whose elements represent the relative perceptual-quality significance levels for the corresponding area/regions for images or video. Due to its generality, PQSM can be incorporated into any visual distortion metrics: to improve effectiveness or/and efficiency of perceptual metrics; or even to enhance a PSNR-based metric. A three-stage PQSM estimation method is also proposed in this paper, with an implementation of motion, texture, luminance, skin-color and face mapping. Experimental results show the scheme can improve the performance of current image/video distortion metrics.

  4. No-Reference Video Quality Assessment by HEVC Codec Analysis

    DEFF Research Database (Denmark)

    Huang, Xin; Søgaard, Jacob; Forchhammer, Søren

    2015-01-01

    This paper proposes a No-Reference (NR) Video Quality Assessment (VQA) method for videos subject to the distortion given by High Efficiency Video Coding (HEVC). The proposed assessment can be performed either as a BitstreamBased (BB) method or as a Pixel-Based (PB). It extracts or estimates...... the transform coefficients, estimates the distortion, and assesses the video quality. The proposed scheme generates VQA features based on Intra coded frames, and then maps features using an Elastic Net to predict subjective video quality. A set of HEVC coded 4K UHD sequences are tested. Results show...... that the quality scores computed by the proposed method are highly correlated with the subjective assessment....

  5. No-reference pixel based video quality assessment for HEVC decoded video

    DEFF Research Database (Denmark)

    Huang, Xin; Søgaard, Jacob; Forchhammer, Søren

    2017-01-01

    the quantization step used in the Intra coding is estimated. We map the obtained HEVC features using an Elastic Net to predict subjective video quality scores, Mean Opinion Scores (MOS). The performance is verified on a dataset consisting of HEVC coded 4 K UHD (resolution equal to 3840 x 2160) video sequences...

  6. Software product quality measurement

    OpenAIRE

    Godliauskas, Eimantas

    2016-01-01

    This paper analyses Ruby product quality measures, suggesting three new measures for Ruby product quality measurement tool Rubocop to measure Ruby product quality characteristics defined in ISO 2502n standard series. This paper consists of four main chapters. The first chapter gives a brief view of software product quality and software product quality measurement. The second chapter analyses object oriented quality measures. The third chapter gives a brief view of the most popular Ruby qualit...

  7. Study of Temporal Effects on Subjective Video Quality of Experience.

    Science.gov (United States)

    Bampis, Christos George; Zhi Li; Moorthy, Anush Krishna; Katsavounidis, Ioannis; Aaron, Anne; Bovik, Alan Conrad

    2017-11-01

    HTTP adaptive streaming is being increasingly deployed by network content providers, such as Netflix and YouTube. By dividing video content into data chunks encoded at different bitrates, a client is able to request the appropriate bitrate for the segment to be played next based on the estimated network conditions. However, this can introduce a number of impairments, including compression artifacts and rebuffering events, which can severely impact an end-user's quality of experience (QoE). We have recently created a new video quality database, which simulates a typical video streaming application, using long video sequences and interesting Netflix content. Going beyond previous efforts, the new database contains highly diverse and contemporary content, and it includes the subjective opinions of a sizable number of human subjects regarding the effects on QoE of both rebuffering and compression distortions. We observed that rebuffering is always obvious and unpleasant to subjects, while bitrate changes may be less obvious due to content-related dependencies. Transient bitrate drops were preferable over rebuffering only on low complexity video content, while consistently low bitrates were poorly tolerated. We evaluated different objective video quality assessment algorithms on our database and found that objective video quality models are unreliable for QoE prediction on videos suffering from both rebuffering events and bitrate changes. This implies the need for more general QoE models that take into account objective quality models, rebuffering-aware information, and memory. The publicly available video content as well as metadata for all of the videos in the new database can be found at http://live.ece.utexas.edu/research/LIVE_NFLXStudy/nflx_index.html.

  8. Evaluating the Accuracy and Quality of the Information in Kyphosis Videos Shared on YouTube.

    Science.gov (United States)

    Erdem, Mehmet Nuri; Karaca, Sinan

    2018-04-16

    A quality-control YouTube-based study using the recognized quality scoring systems. In this study, our aim was to confirm the accuracy and quality of the information in kyphosis videos shared on YouTube. The Internet is a widely and increasingly used source for obtaining medical information both by patients and clinicians. YouTube, in particular, manifests itself as a leading source with its ease of access to information and visual advantage for Internet users. The first 50 videos returned by the YouTube search engine in response to 'kyphosis' keyword query were included in the study and categorized under seven and six groups, based on their source and content. The popularity of the videos were evaluated with a new index called the video power index (VPI). The quality, educational quality and accuracy of the source of information were measured using the JAMA score, Global Quality Score (GQS) and Kyphosis Specific Score (KSS). Videos had a mean duration of 397 seconds and a mean number of views of 131,644, with a total viewing number of 6,582,221. The source (uploader) in 36% of the videos was a trainer and the content in 46% of the videos was exercise training. 72% of the videos were about postural kyphosis. Videos had a mean JAMA score of 1.36 (range: 1 to 4), GQS of 1.68 (range: 1 to 5) and KSS of 3.02 (range:0 to 32). The academic group had the highest scores and the lowest VPIs. Online information on kyphosis is low quality and its contents are of unknown source and accuracy. In order to keep the balance in sharing the right information with the patient, clinicians should possess knowledge about the online information related to their field, and should contribute to the development of optimal medical videos. 3.

  9. Quality of YouTube TM videos on dental implants.

    Science.gov (United States)

    Abukaraky, A; Hamdan, A-A; Ameera, M-N; Nasief, M; Hassona, Y

    2018-07-01

    Patients search YouTube for health-care information. To examine what YouTube offers patients seeking information on dental implants, and to evaluate the quality of provided information. A systematic search of YouTube for videos containing information on dental implants was performed using the key words Dental implant and Tooth replacement. Videos were examined by two senior Oral and Maxillofacial Surgery residents who were trained and calibrated to perform the search. Initial assessment was performed to exclude non- English language videos, duplicate videos, conference lectures, and irrelevant videos. Included videos were analyzed with regard to demographics and content's usefulness. Information for patients available from the American Academy of Implant Dentistry, European Association of Osseointegration, and British Society of Restorative Dentistry were used for benchmarking. A total of 117 videos were analyzed. The most commonly discussed topics were related to procedures involved in dental implantology (76.1%, n=89), and to the indications for dental implants (58.1%, n=78). The mean usefulness score of videos was poor (6.02 ±4.7 [range 0-21]), and misleading content was common (30.1% of videos); mainly in topics related to prognosis and maintenance of dental implants. Most videos (83.1%, n=97) failed to mention the source of information presented in the video or where to find more about dental implants. Information about dental implants on YouTube is limited in quality and quantity. YouTube videos can have a potentially important role in modulating patients attitude and treatment decision regarding dental implants.

  10. Bandwidth allocation for video under quality of service constraints

    CERN Document Server

    Anjum, Bushra

    2014-01-01

    We present queueing-based algorithms to calculate the bandwidth required for a video stream so that the three main Quality of Service constraints, i.e., end-to-end delay, jitter and packet loss, are ensured. Conversational and streaming video-based applications are becoming a major part of the everyday Internet usage. The quality of these applications (QoS), as experienced by the user, depends on three main metrics of the underlying network, namely, end-to-end delay, jitter and packet loss. These metrics are, in turn, directly related to the capacity of the links that the video traffic trave

  11. Frame Rate versus Spatial Quality: Which Video Characteristics Do Matter?

    DEFF Research Database (Denmark)

    Korhonen, Jari; Reiter, Ulrich; Ukhanova, Ann

    2013-01-01

    and temporal quality levels. We also propose simple yet powerful metrics for characterizing spatial and temporal properties of a video sequence, and demonstrate how these metrics can be applied for evaluating the relative impact of spatial and temporal quality on the perceived overall quality....

  12. Predictive no-reference assessment of video quality

    NARCIS (Netherlands)

    Torres Vega, M.; Mocanu, D.C.; Stavrou, S.; Liotta, A.

    2017-01-01

    Among the various means to evaluate the quality of video streams, light-weight No-Reference (NR) methods have low computation and may be executed on thin clients. Thus, these methods would be perfect candidates in cases of real-time quality assessment, automated quality control and in adaptive

  13. Quality Assessment of Compressed Video for Automatic License Plate Recognition

    DEFF Research Database (Denmark)

    Ukhanova, Ann; Støttrup-Andersen, Jesper; Forchhammer, Søren

    2014-01-01

    Definition of video quality requirements for video surveillance poses new questions in the area of quality assessment. This paper presents a quality assessment experiment for an automatic license plate recognition scenario. We explore the influence of the compression by H.264/AVC and H.265/HEVC s...... recognition in our study has a behavior similar to human recognition, allowing the use of the same mathematical models. We furthermore propose an application of one of the models for video surveillance systems......Definition of video quality requirements for video surveillance poses new questions in the area of quality assessment. This paper presents a quality assessment experiment for an automatic license plate recognition scenario. We explore the influence of the compression by H.264/AVC and H.265/HEVC...... standards on the recognition performance. We compare logarithmic and logistic functions for quality modeling. Our results show that a logistic function can better describe the dependence of recognition performance on the quality for both compression standards. We observe that automatic license plate...

  14. Home Video Telemetry vs inpatient telemetry: A comparative study looking at video quality

    Directory of Open Access Journals (Sweden)

    Sutapa Biswas

    Full Text Available Objective: To compare the quality of home video recording with inpatient telemetry (IPT to evaluate our current Home Video Telemetry (HVT practice. Method: To assess our HVT practice, a retrospective comparison of the video quality against IPT was conducted with the latter as the gold standard. A pilot study had been conducted in 2008 on 5 patients.Patients (n = 28 were included in each group over a period of one year.The data was collected from referral spreadsheets, King’s EPR and telemetry archive.Scoring of the events captured was by consensus using two scorers.The variables compared included: visibility of the body part of interest, visibility of eyes, time of event, illumination, contrast, sound quality and picture clarity when amplified to 200%.Statistical evaluation was carried out using Shapiro–Wilk and Chi-square tests. The P-value of ⩽0.05 was considered statistically significant. Results: Significant differences were demonstrated in lighting and contrast between the two groups (HVT performed better in both.Amplified picture quality was slightly better in the HVT group. Conclusion: Video quality of HVT is comparable to IPT, even surpassing IPT in certain aspects such as the level of illumination and contrast. Results were reconfirmed in a larger sample of patients with more variables. Significance: Despite the user and environmental variability in HVT, it looks promising and can be seriously considered as a preferable alternative for patients who may require investigation at locations remote from an EEG laboratory. Keywords: Home Video Telemetry, EEG, Home video monitoring, Video quality

  15. Balancing Attended and Global Stimuli in Perceived Video Quality Assessment

    DEFF Research Database (Denmark)

    You, Junyong; Korhonen, Jari; Perkis, Andrew

    2011-01-01

    . This paper proposes a quality model based on the late attention selection theory, assuming that the video quality is perceived via two mechanisms: global and local quality assessment. First we model several visual features influencing the visual attention in quality assessment scenarios to derive......The visual attention mechanism plays a key role in the human perception system and it has a significant impact on our assessment of perceived video quality. In spite of receiving less attention from the viewers, unattended stimuli can still contribute to the understanding of the visual content...... an attention map using appropriate fusion techniques. The global quality assessment as based on the assumption that viewers allocate their attention equally to the entire visual scene, is modeled by four carefully designed quality features. By employing these same quality features, the local quality model...

  16. Encryption for confidentiality of the network and influence of this to the quality of streaming video through network

    Science.gov (United States)

    Sevcik, L.; Uhrin, D.; Frnda, J.; Voznak, M.; Toral-Cruz, Homer; Mikulec, M.; Jakovlev, Sergej

    2015-05-01

    Nowadays, the interest in real-time services, like audio and video, is growing. These services are mostly transmitted over packet networks, which are based on IP protocol. It leads to analyses of these services and their behavior in such networks which are becoming more frequent. Video has become the significant part of all data traffic sent via IP networks. In general, a video service is one-way service (except e.g. video calls) and network delay is not such an important factor as in a voice service. Dominant network factors that influence the final video quality are especially packet loss, delay variation and the capacity of the transmission links. Analysis of video quality concentrates on the resistance of video codecs to packet loss in the network, which causes artefacts in the video. IPsec provides confidentiality in terms of safety, integrity and non-repudiation (using HMAC-SHA1 and 3DES encryption for confidentiality and AES in CBC mode) with an authentication header and ESP (Encapsulating Security Payload). The paper brings a detailed view of the performance of video streaming over an IP-based network. We compared quality of video with packet loss and encryption as well. The measured results demonstrated the relation between the video codec type and bitrate to the final video quality.

  17. Educational quality of YouTube videos on knee arthrocentesis.

    Science.gov (United States)

    Fischer, Jonas; Geurts, Jeroen; Valderrabano, Victor; Hügle, Thomas

    2013-10-01

    Knee arthrocentesis is a commonly performed diagnostic and therapeutic procedure in rheumatology and orthopedic surgery. Classic teaching of arthrocentesis skills relies on hands-on practice under supervision. Video-based online teaching is an increasingly utilized educational tool in higher and clinical education. YouTube is a popular video-sharing Web site that can be accessed as a teaching source. The objective of this study was to assess the educational value of YouTube videos on knee arthrocentesis posted by health professionals and institutions during the period from 2008 to 2012. The YouTube video database was systematically searched using 5 search terms related to knee arthrocentesis. Two independent clinical reviewers assessed videos for procedural technique and educational value using a 5-point global score, ranging from 1 = poor quality to 5 = excellent educational quality. As validated international guidelines are lacking, we used the guidelines of the Swiss Society of Rheumatology as criterion standard for the procedure. Of more than thousand findings, 13 videos met the inclusion criteria. Of those, 2 contained additional animated video material: one was purely animated, and one was a check list. The average length was 3.31 ± 2.28 minutes. The most popular video had 1388 hits per month. Our mean global score for educational value was 3.1 ± 1.0. Eight videos (62 %) were considered useful for teaching purposes. Use of a "no-touch" procedure, meaning that once disinfected the skin remains untouched before needle penetration, was present in all videos. Six videos (46%) demonstrated full sterile conditions. There was no clear preference of a medial (n = 8) versus lateral (n = 5) approach. A discreet number of YouTube videos on knee arthrocentesis appeared to be suitable for application in a Web-based format for medical students, fellows, and residents. The low-average mean global score for overall educational value suggests an improvement of future video

  18. The art of assessing quality for images and video

    International Nuclear Information System (INIS)

    Deriche, M.

    2011-01-01

    The early years of this century have witnessed a tremendous growth in the use of digital multimedia data for di?erent communication applications. Researchers from around the world are spending substantial research efforts in developing techniques for improving the appearance of images/video. However, as we know, preserving high quality is a challenging task. Images are subject to distortions during acquisition, compression, transmission, analysis, and reconstruction. For this reason, the research area focusing on image and video quality assessment has attracted a lot of attention in recent years. In particular, compression applications and other multimedia applications need powerful techniques for evaluating quality objectively without human interference. This tutorial will cover the di?erent faces of image quality assessment. We will motivate the need for robust image quality assessment techniques, then discuss the main algorithms found in the literature with a critical perspective. We will present the di?erent metrics used for full reference, reduced reference and no reference applications. We will then discuss the difference between image and video quality assessment. In all of the above, we will take a critical approach to explain which metric can be used for which application. Finally we will discuss the different approaches to analyze the performance of image/video quality metrics, and end the tutorial with some perspectives on newly introduced metrics and their potential applications.

  19. Modeling the time--varying subjective quality of HTTP video streams with rate adaptations.

    Science.gov (United States)

    Chen, Chao; Choi, Lark Kwon; de Veciana, Gustavo; Caramanis, Constantine; Heath, Robert W; Bovik, Alan C

    2014-05-01

    Newly developed hypertext transfer protocol (HTTP)-based video streaming technologies enable flexible rate-adaptation under varying channel conditions. Accurately predicting the users' quality of experience (QoE) for rate-adaptive HTTP video streams is thus critical to achieve efficiency. An important aspect of understanding and modeling QoE is predicting the up-to-the-moment subjective quality of a video as it is played, which is difficult due to hysteresis effects and nonlinearities in human behavioral responses. This paper presents a Hammerstein-Wiener model for predicting the time-varying subjective quality (TVSQ) of rate-adaptive videos. To collect data for model parameterization and validation, a database of longer duration videos with time-varying distortions was built and the TVSQs of the videos were measured in a large-scale subjective study. The proposed method is able to reliably predict the TVSQ of rate adaptive videos. Since the Hammerstein-Wiener model has a very simple structure, the proposed method is suitable for online TVSQ prediction in HTTP-based streaming.

  20. Quality assurance testing on video games : The importance and impact of a misunderstood industry

    OpenAIRE

    Ruuska, Essi

    2015-01-01

    The aim of this research was to provide a more holistic insight of the video game quality assurance industry to video game industry professionals and prospective employees in order to promote the importance and impact of quality assurance testing in video games. The motive for this thesis came from the author's work experience in video game quality assurance testing, and from realizing how little is known about the industry. The research question was defined as 'what is video game quality ass...

  1. Computed Quality Assessment of MPEG4-compressed DICOM Video Data.

    Science.gov (United States)

    Frankewitsch, Thomas; Söhnlein, Sven; Müller, Marcel; Prokosch, Hans-Ulrich

    2005-01-01

    Digital Imaging and Communication in Medicine (DICOM) has become one of the most popular standards in medicine. This standard specifies the exact procedures in which digital images are exchanged between devices, either using a network or storage medium. Sources for images vary; therefore there exist definitions for the exchange for CR, CT, NMR, angiography, sonography and so on. With its spreading, with the increasing amount of sources included, data volume is increasing, too. This affects storage and traffic. While for long-time storage data compression is generally not accepted at the moment, there are many situations where data compression is possible: Telemedicine for educational purposes (e.g. students at home using low speed internet connections), presentations with standard-resolution video projectors, or even the supply on wards combined receiving written findings. DICOM comprises compression: for still image there is JPEG, for video MPEG-2 is adopted. Within the last years MPEG-2 has been evolved to MPEG-4, which squeezes data even better, but the risk of significant errors increases, too. Within the last years effects of compression have been analyzed for entertainment movies, but these are not comparable to videos of physical examinations (e.g. echocardiography). In medical videos an individual image plays a more important role. Erroneous single images affect total quality even more. Additionally, the effect of compression can not be generalized from one test series to all videos. The result depends strongly on the source. Some investigations have been presented, where different MPEG-4 algorithms compressed videos have been compared and rated manually. But they describe only the results in an elected testbed. In this paper some methods derived from video rating are presented and discussed for an automatically created quality control for the compression of medical videos, primary stored in DICOM containers.

  2. A model linking video gaming, sleep quality, sweet drinks consumption and obesity among children and youth.

    Science.gov (United States)

    Turel, O; Romashkin, A; Morrison, K M

    2017-08-01

    There is a growing need to curb paediatric obesity. The aim of this study is to untangle associations between video-game-use attributes and obesity as a first step towards identifying and examining possible interventions. Cross-sectional time-lagged cohort study was employed using parent-child surveys (t1) and objective physical activity and physiological measures (t2) from 125 children/adolescents (mean age = 13.06, 9-17-year-olds) who play video games, recruited from two clinics at a Canadian academic children's hospital. Structural equation modelling and analysis of covariance were employed for inference. The results of the study are as follows: (i) self-reported video-game play duration in the 4-h window before bedtime is related to greater abdominal adiposity (waist-to-height ratio) and this association may be mediated through reduced sleep quality (measured with the Pittsburgh Sleep Quality Index); and (ii) self-reported average video-game session duration is associated with greater abdominal adiposity and this association may be mediated through higher self-reported sweet drinks consumption while playing video games and reduced sleep quality. Video-game play duration in the 4-h window before bedtime, typical video-game session duration, sweet drinks consumption while playing video games and poor sleep quality have aversive associations with abdominal adiposity. Paediatricians and researchers should further explore how these factors can be altered through behavioural or pharmacological interventions as a means to reduce paediatric obesity. © 2017 World Obesity Federation.

  3. Concerns of Quality and Safety in Public Domain Surgical Education Videos: An Assessment of the Critical View of Safety in Frequently Used Laparoscopic Cholecystectomy Videos.

    Science.gov (United States)

    Deal, Shanley B; Alseidi, Adnan A

    2017-12-01

    Online videos are among the most common resources for case preparation. Using crowd sourcing, we evaluated the relationship between operative quality and viewing characteristics of online laparoscopic cholecystectomy videos. We edited 160 online videos of laparoscopic cholecystectomy to 60 seconds or less. Crowd workers (CW) rated videos using Global Objective Assessment of Laparoscopic Skills (GOALS), the critical view of safety (CVS) criteria, and assigned overall pass/fail ratings if CVS was achieved; linear mixed effects models derived average ratings. Views, likes, dislikes, subscribers, and country were recorded for subset analysis of YouTube videos. Spearman correlation coefficient (SCC) assessed correlation between performance measures. One video (0.06%) achieved a passing CVS score of ≥5; 23%, ≥4; 44%, ≥3; 79%, ≥2; and 100% ≥1. Pass/fail ratings correlated to CVS, SCC 0.95 (p quality. The average CVS and GOALS scores were no different for videos with >20,000 views (22%) compared with those with online surgical videos of LC. Favorable characteristics, such as number of views or likes, do not translate to higher quality. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Weighted-MSE based on saliency map for assessing video quality of H.264 video streams

    Science.gov (United States)

    Boujut, H.; Benois-Pineau, J.; Hadar, O.; Ahmed, T.; Bonnet, P.

    2011-01-01

    Human vision system is very complex and has been studied for many years specifically for purposes of efficient encoding of visual, e.g. video content from digital TV. There have been physiological and psychological evidences which indicate that viewers do not pay equal attention to all exposed visual information, but only focus on certain areas known as focus of attention (FOA) or saliency regions. In this work, we propose a novel based objective quality assessment metric, for assessing the perceptual quality of decoded video sequences affected by transmission errors and packed loses. The proposed method weights the Mean Square Error (MSE), Weighted-MSE (WMSE), according to the calculated saliency map at each pixel. Our method was validated trough subjective quality experiments.

  5. Compensating for Type-I Errors in Video Quality Assessment

    DEFF Research Database (Denmark)

    Brunnström, Kjell; Tavakoli, Samira; Søgaard, Jacob

    2015-01-01

    This paper analyzes the impact on compensating for Type-I errors in video quality assessment. A Type-I error is to incorrectly conclude that there is an effect. The risk increases with the number of comparisons that are performed in statistical tests. Type-I errors are an issue often neglected...

  6. A regression method for real-time video quality evaluation

    NARCIS (Netherlands)

    Torres Vega, M.; Mocanu, D.C.; Liotta, A.; Abdulrazak, B.; Pardede, E.; Steinbauer, M.; Khalil, I.; Anderst-Kotsis, G.

    2016-01-01

    No-Reference (NR) metrics provide a mechanism to assess video quality in an ever-growing wireless network. Their low computational complexity and functional characteristics make them the primary choice when it comes to realtime content management and mobile streaming control. Unfortunately, common

  7. Video Quality Assessment Using Spatio-Velocity Contrast Sensitivity Function

    Science.gov (United States)

    Hirai, Keita; Tumurtogoo, Jambal; Kikuchi, Ayano; Tsumura, Norimichi; Nakaguchi, Toshiya; Miyake, Yoichi

    Due to the development and popularization of high-definition televisions, digital video cameras, Blu-ray discs, digital broadcasting, IP television and so on, it plays an important role to identify and quantify video quality degradations. In this paper, we propose SV-CIELAB which is an objective video quality assessment (VQA) method using a spatio-velocity contrast sensitivity function (SV-CSF). In SV-CIELAB, motion information in videos is effectively utilized for filtering unnecessary information in the spatial frequency domain. As the filter to apply videos, we used the SV-CSF. It is a modulation transfer function of the human visual system, and consists of the relationship among contrast sensitivities, spatial frequencies and velocities of perceived stimuli. In the filtering process, the SV-CSF cannot be directly applied in the spatial frequency domain because spatial coordinate information is required when using velocity information. For filtering by the SV-CSF, we obtain video frames separated in spatial frequency domain. By using velocity information, the separated frames with limited spatial frequencies are weighted by contrast sensitivities in the SV-CSF model. In SV-CIELAB, the criteria are obtained by calculating image differences between filtered original and distorted videos. For the validation of SV-CIELAB, subjective evaluation experiments were conducted. The subjective experimental results were compared with SV-CIELAB and the conventional VQA methods such as CIELAB color difference, Spatial-CIELAB, signal to noise ratio and so on. From the experimental results, it was shown that SV-CIELAB is a more efficient VQA method than the conventional methods.

  8. Impact of Constant Rate Factor on Objective Video Quality Assessment

    Directory of Open Access Journals (Sweden)

    Juraj Bienik

    2017-01-01

    Full Text Available This paper deals with the impact of constant rate factor value on the objective video quality assessment using PSNR and SSIM metrics. Compression efficiency of H.264 and H.265 codecs defined by different Constant rate factor (CRF values was tested. The assessment was done for eight types of video sequences depending on content for High Definition (HD, Full HD (FHD and Ultra HD (UHD resolution. Finally, performance of both mentioned codecs with emphasis on compression ratio and efficiency of coding was compared.

  9. Video Quality Assessment and Machine Learning: Performance and Interpretability

    DEFF Research Database (Denmark)

    Søgaard, Jacob; Forchhammer, Søren; Korhonen, Jari

    2015-01-01

    In this work we compare a simple and a complex Machine Learning (ML) method used for the purpose of Video Quality Assessment (VQA). The simple ML method chosen is the Elastic Net (EN), which is a regularized linear regression model and easier to interpret. The more complex method chosen is Support...... Vector Regression (SVR), which has gained popularity in VQA research. Additionally, we present an ML-based feature selection method. Also, it is investigated how well the methods perform when tested on videos from other datasets. Our results show that content-independent cross-validation performance...... on a single dataset can be misleading and that in the case of very limited training and test data, especially in regards to different content as is the case for many video datasets, a simple ML approach is the better choice....

  10. Operation quality assessment model for video conference system

    Science.gov (United States)

    Du, Bangshi; Qi, Feng; Shao, Sujie; Wang, Ying; Li, Weijian

    2018-01-01

    Video conference system has become an important support platform for smart grid operation and management, its operation quality is gradually concerning grid enterprise. First, the evaluation indicator system covering network, business and operation maintenance aspects was established on basis of video conference system's operation statistics. Then, the operation quality assessment model combining genetic algorithm with regularized BP neural network was proposed, which outputs operation quality level of the system within a time period and provides company manager with some optimization advice. The simulation results show that the proposed evaluation model offers the advantages of fast convergence and high prediction accuracy in contrast with regularized BP neural network, and its generalization ability is superior to LM-BP neural network and Bayesian BP neural network.

  11. MDS Quality Measures

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of the quality measures displayed on Nursing Home Compare, excluding Measures of Rehospitalization, Emergency Room Visit, and Community Discharge. Each row...

  12. Recurrent and Dynamic Models for Predicting Streaming Video Quality of Experience.

    Science.gov (United States)

    Bampis, Christos G; Li, Zhi; Katsavounidis, Ioannis; Bovik, Alan C

    2018-07-01

    Streaming video services represent a very large fraction of global bandwidth consumption. Due to the exploding demands of mobile video streaming services, coupled with limited bandwidth availability, video streams are often transmitted through unreliable, low-bandwidth networks. This unavoidably leads to two types of major streaming-related impairments: compression artifacts and/or rebuffering events. In streaming video applications, the end-user is a human observer; hence being able to predict the subjective Quality of Experience (QoE) associated with streamed videos could lead to the creation of perceptually optimized resource allocation strategies driving higher quality video streaming services. We propose a variety of recurrent dynamic neural networks that conduct continuous-time subjective QoE prediction. By formulating the problem as one of time-series forecasting, we train a variety of recurrent neural networks and non-linear autoregressive models to predict QoE using several recently developed subjective QoE databases. These models combine multiple, diverse neural network inputs, such as predicted video quality scores, rebuffering measurements, and data related to memory and its effects on human behavioral responses, using them to predict QoE on video streams impaired by both compression artifacts and rebuffering events. Instead of finding a single time-series prediction model, we propose and evaluate ways of aggregating different models into a forecasting ensemble that delivers improved results with reduced forecasting variance. We also deploy appropriate new evaluation metrics for comparing time-series predictions in streaming applications. Our experimental results demonstrate improved prediction performance that approaches human performance. An implementation of this work can be found at https://github.com/christosbampis/NARX_QoE_release.

  13. Video quality of 3G videophones for telephone cardiopulmonary resuscitation.

    Science.gov (United States)

    Tränkler, Uwe; Hagen, Oddvar; Horsch, Alexander

    2008-01-01

    We simulated a cardiopulmonary resuscitation (CPR) scene with a manikin and used two 3G videophones on the caller's side to transmit video to a laptop PC. Five observers (two doctors with experience in emergency medicine and three paramedics) evaluated the video. They judged whether the manikin was breathing and whether they would give advice for CPR; they also graded the confidence of their decision-making. Breathing was only visible from certain orientations of the videophones, at distances below 150 cm with good illumination and a still background. Since the phones produced a degradation in colours and shadows, detection of breathing mainly depended on moving contours. Low camera positioning produced better results than having the camera high up. Darkness, shaking of the camera and a moving background made detection of breathing almost impossible. The video from the two 3G videophones that were tested was of sufficient quality for telephone CPR provided that camera orientation, distance, illumination and background were carefully chosen. Thus it seems possible to use 3G videophones for emergency calls involving CPR. However, further studies on the required video quality in different scenarios are necessary.

  14. Measurement quality assurance

    International Nuclear Information System (INIS)

    Eisenhower, E.H.

    1988-01-01

    The quality of a radiation protection program can be no better than the quality of the measurements made to support it. In many cases, that quality is unknown and is merely implied on the basis of a calibration of a measuring instrument. If that calibration is inappropriate or is performed improperly, the measurement result will be inaccurate and misleading. Assurance of measurement quality can be achieved if appropriate procedures are followed, including periodic quality control actions that demonstrate adequate performance. Several national measurement quality assurance (MQA) programs are operational or under development in specific areas. They employ secondary standards laboratories that provide a high-quality link between the National Bureau of Standards and measurements made at the field use level. The procedures followed by these secondary laboratories to achieve MQA will be described, as well as plans for similar future programs. A growing general national interest in quality assurance, combined with strong specific motivations for MQA in the area of ionizing radiation, will provide continued demand for appropriate national programs. Such programs must, however, employ procedures that are cost effective and must be developed with participation by all affected parties

  15. Measuring energy expenditure in sports by thermal video analysis

    DEFF Research Database (Denmark)

    Gade, Rikke; Larsen, Ryan Godsk; Moeslund, Thomas B.

    2017-01-01

    Estimation of human energy expenditure in sports and exercise contributes to performance analyses and tracking of physical activity levels. The focus of this work is to develop a video-based method for estimation of energy expenditure in athletes. We propose a method using thermal video analysis...... to automatically extract the cyclic motion pattern, in walking and running represented as steps, and analyse the frequency. Experiments are performed with one subject in two different tests, each at 5, 8, 10, and 12 km/h. The results of our proposed video-based method is compared to concurrent measurements...

  16. Predicting personal preferences in subjective video quality assessment

    DEFF Research Database (Denmark)

    Korhonen, Jari

    2017-01-01

    In this paper, we study the problem of predicting the visual quality of a specific test sample (e.g. a video clip) experienced by a specific user, based on the ratings by other users for the same sample and the same user for other samples. A simple linear model and algorithm is presented, where...... the characteristics of each test sample are represented by a set of parameters, and the individual preferences are represented by weights for the parameters. According to the validation experiment performed on public visual quality databases annotated with raw individual scores, the proposed model can predict...

  17. Nonintrusive Method Based on Neural Networks for Video Quality of Experience Assessment

    Directory of Open Access Journals (Sweden)

    Diego José Luis Botia Valderrama

    2016-01-01

    Full Text Available The measurement and evaluation of the QoE (Quality of Experience have become one of the main focuses in the telecommunications to provide services with the expected quality for their users. However, factors like the network parameters and codification can affect the quality of video, limiting the correlation between the objective and subjective metrics. The above increases the complexity to evaluate the real quality of video perceived by users. In this paper, a model based on artificial neural networks such as BPNNs (Backpropagation Neural Networks and the RNNs (Random Neural Networks is applied to evaluate the subjective quality metrics MOS (Mean Opinion Score and the PSNR (Peak Signal Noise Ratio, SSIM (Structural Similarity Index Metric, VQM (Video Quality Metric, and QIBF (Quality Index Based Frame. The proposed model allows establishing the QoS (Quality of Service based in the strategy Diffserv. The metrics were analyzed through Pearson’s and Spearman’s correlation coefficients, RMSE (Root Mean Square Error, and outliers rate. Correlation values greater than 90% were obtained for all the evaluated metrics.

  18. Objective video quality assessment method for freeze distortion based on freeze aggregation

    Science.gov (United States)

    Watanabe, Keishiro; Okamoto, Jun; Kurita, Takaaki

    2006-01-01

    With the development of the broadband network, video communications such as videophone, video distribution, and IPTV services are beginning to become common. In order to provide these services appropriately, we must manage them based on subjective video quality, in addition to designing a network system based on it. Currently, subjective quality assessment is the main method used to quantify video quality. However, it is time-consuming and expensive. Therefore, we need an objective quality assessment technology that can estimate video quality from video characteristics effectively. Video degradation can be categorized into two types: spatial and temporal. Objective quality assessment methods for spatial degradation have been studied extensively, but methods for temporal degradation have hardly been examined even though it occurs frequently due to network degradation and has a large impact on subjective quality. In this paper, we propose an objective quality assessment method for temporal degradation. Our approach is to aggregate multiple freeze distortions into an equivalent freeze distortion and then derive the objective video quality from the equivalent freeze distortion. Specifically, our method considers the total length of all freeze distortions in a video sequence as the length of the equivalent single freeze distortion. In addition, we propose a method using the perceptual characteristics of short freeze distortions. We verified that our method can estimate the objective video quality well within the deviation of subjective video quality.

  19. Quality of Experience management for video streams : the case of Skype

    NARCIS (Netherlands)

    Liotta, A.; Druda, L.; Exarchakos, G.; Menkovski, V.; Khalil, I.

    2012-01-01

    With the widespread adoption of mobile Internet, the process of streaming video has become varied and complex. A diversity of factors affect the way we perceive quality in video streaming (also known as 'quality of experience', or QoE), involving far more than the individual video and network

  20. Video-Quality Estimation Based on Reduced-Reference Model Employing Activity-Difference

    Science.gov (United States)

    Yamada, Toru; Miyamoto, Yoshihiro; Senda, Yuzo; Serizawa, Masahiro

    This paper presents a Reduced-reference based video-quality estimation method suitable for individual end-user quality monitoring of IPTV services. With the proposed method, the activity values for individual given-size pixel blocks of an original video are transmitted to end-user terminals. At the end-user terminals, the video quality of a received video is estimated on the basis of the activity-difference between the original video and the received video. Psychovisual weightings and video-quality score adjustments for fatal degradations are applied to improve estimation accuracy. In addition, low-bit-rate transmission is achieved by using temporal sub-sampling and by transmitting only the lower six bits of each activity value. The proposed method achieves accurate video quality estimation using only low-bit-rate original video information (15kbps for SDTV). The correlation coefficient between actual subjective video quality and estimated quality is 0.901 with 15kbps side information. The proposed method does not need computationally demanding spatial and gain-and-offset registrations. Therefore, it is suitable for real-time video-quality monitoring in IPTV services.

  1. Influence of video compression on the measurement error of the television system

    Science.gov (United States)

    Sotnik, A. V.; Yarishev, S. N.; Korotaev, V. V.

    2015-05-01

    Video data require a very large memory capacity. Optimal ratio quality / volume video encoding method is one of the most actual problem due to the urgent need to transfer large amounts of video over various networks. The technology of digital TV signal compression reduces the amount of data used for video stream representation. Video compression allows effective reduce the stream required for transmission and storage. It is important to take into account the uncertainties caused by compression of the video signal in the case of television measuring systems using. There are a lot digital compression methods. The aim of proposed work is research of video compression influence on the measurement error in television systems. Measurement error of the object parameter is the main characteristic of television measuring systems. Accuracy characterizes the difference between the measured value abd the actual parameter value. Errors caused by the optical system can be selected as a source of error in the television systems measurements. Method of the received video signal processing is also a source of error. Presence of error leads to large distortions in case of compression with constant data stream rate. Presence of errors increases the amount of data required to transmit or record an image frame in case of constant quality. The purpose of the intra-coding is reducing of the spatial redundancy within a frame (or field) of television image. This redundancy caused by the strong correlation between the elements of the image. It is possible to convert an array of image samples into a matrix of coefficients that are not correlated with each other, if one can find corresponding orthogonal transformation. It is possible to apply entropy coding to these uncorrelated coefficients and achieve a reduction in the digital stream. One can select such transformation that most of the matrix coefficients will be almost zero for typical images . Excluding these zero coefficients also

  2. Applicability of Existing Objective Metrics of Perceptual Quality for Adaptive Video Streaming

    DEFF Research Database (Denmark)

    Søgaard, Jacob; Krasula, Lukás; Shahid, Muhammad

    2016-01-01

    Objective video quality metrics are designed to estimate the quality of experience of the end user. However, these objective metrics are usually validated with video streams degraded under common distortion types. In the presented work, we analyze the performance of published and known full......-reference and noreference quality metrics in estimating the perceived quality of adaptive bit-rate video streams knowingly out of scope. Experimental results indicate not surprisingly that state of the art objective quality metrics overlook the perceived degradations in the adaptive video streams and perform poorly...

  3. An Energy-Efficient and High-Quality Video Transmission Architecture in Wireless Video-Based Sensor Networks

    Directory of Open Access Journals (Sweden)

    Yasaman Samei

    2008-08-01

    Full Text Available Technological progress in the fields of Micro Electro-Mechanical Systems (MEMS and wireless communications and also the availability of CMOS cameras, microphones and small-scale array sensors, which may ubiquitously capture multimedia content from the field, have fostered the development of low-cost limited resources Wireless Video-based Sensor Networks (WVSN. With regards to the constraints of videobased sensor nodes and wireless sensor networks, a supporting video stream is not easy to implement with the present sensor network protocols. In this paper, a thorough architecture is presented for video transmission over WVSN called Energy-efficient and high-Quality Video transmission Architecture (EQV-Architecture. This architecture influences three layers of communication protocol stack and considers wireless video sensor nodes constraints like limited process and energy resources while video quality is preserved in the receiver side. Application, transport, and network layers are the layers in which the compression protocol, transport protocol, and routing protocol are proposed respectively, also a dropping scheme is presented in network layer. Simulation results over various environments with dissimilar conditions revealed the effectiveness of the architecture in improving the lifetime of the network as well as preserving the video quality.

  4. An Energy-Efficient and High-Quality Video Transmission Architecture in Wireless Video-Based Sensor Networks.

    Science.gov (United States)

    Aghdasi, Hadi S; Abbaspour, Maghsoud; Moghadam, Mohsen Ebrahimi; Samei, Yasaman

    2008-08-04

    Technological progress in the fields of Micro Electro-Mechanical Systems (MEMS) and wireless communications and also the availability of CMOS cameras, microphones and small-scale array sensors, which may ubiquitously capture multimedia content from the field, have fostered the development of low-cost limited resources Wireless Video-based Sensor Networks (WVSN). With regards to the constraints of videobased sensor nodes and wireless sensor networks, a supporting video stream is not easy to implement with the present sensor network protocols. In this paper, a thorough architecture is presented for video transmission over WVSN called Energy-efficient and high-Quality Video transmission Architecture (EQV-Architecture). This architecture influences three layers of communication protocol stack and considers wireless video sensor nodes constraints like limited process and energy resources while video quality is preserved in the receiver side. Application, transport, and network layers are the layers in which the compression protocol, transport protocol, and routing protocol are proposed respectively, also a dropping scheme is presented in network layer. Simulation results over various environments with dissimilar conditions revealed the effectiveness of the architecture in improving the lifetime of the network as well as preserving the video quality.

  5. Is perception of quality more important than technical quality in patient video cases?

    Science.gov (United States)

    Roland, Damian; Matheson, David; Taub, Nick; Coats, Tim; Lakhanpaul, Monica

    2015-08-13

    The use of video cases to demonstrate key signs and symptoms in patients (patient video cases or PVCs) is a rapidly expanding field. The aims of this study were to evaluate whether the technical quality, or judgement of quality, of a video clip influences a paediatrician's judgment on acuity of the case and assess the relationship between perception of quality and the technical quality of a selection of video clips. Participants (12 senior consultant paediatricians attending an examination workshop) individually categorised 28 PVCs into one of 3 possible acuities and then described the quality of the image seen. The PVCs had been converted into four different technical qualities (differing bit rates ranging from excellent to low quality). Participants' assessment of quality and the actual industry standard of the PVC were independent (333 distinct observations, spearmans rho = 0.0410, p = 0.4564). Agreement between actual acuity and participants' judgement was generally good at higher acuities but moderate at medium/low acuities of illness (overall correlation 0.664). Perception of the quality of the clip was related to correct assignment of acuity regardless of the technical quality of the clip (number of obs = 330, z = 2.07, p = 0.038). It is important to benchmark PVCs prior to use in learning resources as experts may not agree on the information within, or quality of, the clip. It appears, although PVCs may be beneficial in a pedagogical context, the perception of quality of clip may be an important determinant of an expert's decision making.

  6. Diagnostic image quality of video-digitized chest images

    International Nuclear Information System (INIS)

    Winter, L.H.; Butler, R.B.; Becking, W.B.; Warnars, G.A.O.; Haar Romeny, B. ter; Ottes, F.P.; Valk, J.-P.J. de

    1989-01-01

    The diagnostic accuracy obtained with the Philips picture archiving and communications subsystem was investigated by means of an observer performance study using receiver operating characteristic (ROC) analysis. The image qualities of conventional films and video digitized images were compared. The scanner had a 1024 x 1024 x 8 bit memory. The digitized images were displayed on a 60 Hz interlaced display monitor 1024 lines. Posteroanterior (AP) roetgenograms of a chest phantom with superimposed simulated interstitial pattern disease (IPD) were produced; there were 28 normal and 40 abnormal films. Normal films were produced by the chest phantom alone. Abnormal films were taken of the chest phantom with varying degrees of superimposed simulated intersitial disease (PND) for an observer performance study, because the results of a simulated interstitial pattern disease study are less likely to be influenced by perceptual capabilities. The conventional films and the video digitized images were viewed by five experienced observers during four separate sessions. Conventional films were presented on a viewing box, the digital images were displayed on the monitor described above. The presence of simulated intersitial disease was indicated on a 5-point ROC certainty scale by each observer. We analyzed the differences between ROC curves derived from correlated data statistically. The mean time required to evaluate 68 digitized images is approximately four times the mean time needed to read the convential films. The diagnostic quality of the video digitized images was significantly lower (at the 5% level) than that of the conventional films (median area under the curve (AUC) of 0.71 and 0.94, respectively). (author). 25 refs.; 2 figs.; 4 tabs

  7. Quality of pharmaceutical care at the pharmacy counter: patients' experiences versus video observation.

    Science.gov (United States)

    Koster, Ellen S; Blom, Lyda; Overbeeke, Marloes R; Philbert, Daphne; Vervloet, Marcia; Koopman, Laura; van Dijk, Liset

    2016-01-01

    Consumer Quality Index questionnaires are used to assess quality of care from patients' experiences. To provide insight into the agreement about quality of pharmaceutical care, measured both by a patient questionnaire and video observations. Pharmaceutical encounters in four pharmacies were video-recorded. Patients completed a questionnaire based upon the Consumer Quality Index Pharmaceutical Care after the encounter containing questions about patients' experiences regarding information provision, medication counseling, and pharmacy staff's communication style. An observation protocol was used to code the recorded encounters. Agreement between video observation and patients' experiences was calculated. In total, 109 encounters were included for analysis. For the domains "medication counseling" and "communication style", agreement between patients' experiences and observations was very high (>90%). Less agreement (45%) was found for "information provision", which was rated more positive by patients compared to the observations, especially for the topic, encouragement of patients' questioning behavior. A questionnaire is useful to assess the quality of medication counseling and pharmacy staff's communication style, but might be less suitable to evaluate information provision and pharmacy staff's encouragement of patients' questioning behavior. Although patients may believe that they have received all necessary information to use their new medicine, some information on specific instructions was not addressed during the encounter. When using questionnaires to get insight into information provision, observations of encounters are very informative to validate the patient questionnaires and make necessary adjustments.

  8. Quality of pharmaceutical care at the pharmacy counter: patients’ experiences versus video observation

    Science.gov (United States)

    Koster, Ellen S; Blom, Lyda; Overbeeke, Marloes R; Philbert, Daphne; Vervloet, Marcia; Koopman, Laura; van Dijk, Liset

    2016-01-01

    Introduction Consumer Quality Index questionnaires are used to assess quality of care from patients’ experiences. Objective To provide insight into the agreement about quality of pharmaceutical care, measured both by a patient questionnaire and video observations. Methods Pharmaceutical encounters in four pharmacies were video-recorded. Patients completed a questionnaire based upon the Consumer Quality Index Pharmaceutical Care after the encounter containing questions about patients’ experiences regarding information provision, medication counseling, and pharmacy staff’s communication style. An observation protocol was used to code the recorded encounters. Agreement between video observation and patients’ experiences was calculated. Results In total, 109 encounters were included for analysis. For the domains “medication counseling” and “communication style”, agreement between patients’ experiences and observations was very high (>90%). Less agreement (45%) was found for “information provision”, which was rated more positive by patients compared to the observations, especially for the topic, encouragement of patients’ questioning behavior. Conclusion A questionnaire is useful to assess the quality of medication counseling and pharmacy staff’s communication style, but might be less suitable to evaluate information provision and pharmacy staff’s encouragement of patients’ questioning behavior. Although patients may believe that they have received all necessary information to use their new medicine, some information on specific instructions was not addressed during the encounter. When using questionnaires to get insight into information provision, observations of encounters are very informative to validate the patient questionnaires and make necessary adjustments. PMID:27042025

  9. Degraded visual environment image/video quality metrics

    Science.gov (United States)

    Baumgartner, Dustin D.; Brown, Jeremy B.; Jacobs, Eddie L.; Schachter, Bruce J.

    2014-06-01

    A number of image quality metrics (IQMs) and video quality metrics (VQMs) have been proposed in the literature for evaluating techniques and systems for mitigating degraded visual environments. Some require both pristine and corrupted imagery. Others require patterned target boards in the scene. None of these metrics relates well to the task of landing a helicopter in conditions such as a brownout dust cloud. We have developed and used a variety of IQMs and VQMs related to the pilot's ability to detect hazards in the scene and to maintain situational awareness. Some of these metrics can be made agnostic to sensor type. Not only are the metrics suitable for evaluating algorithm and sensor variation, they are also suitable for choosing the most cost effective solution to improve operating conditions in degraded visual environments.

  10. On the definition of adapted audio/video profiles for high-quality video calling services over LTE/4G

    Science.gov (United States)

    Ndiaye, Maty; Quinquis, Catherine; Larabi, Mohamed Chaker; Le Lay, Gwenael; Saadane, Hakim; Perrine, Clency

    2014-01-01

    During the last decade, the important advances and widespread availability of mobile technology (operating systems, GPUs, terminal resolution and so on) have encouraged a fast development of voice and video services like video-calling. While multimedia services have largely grown on mobile devices, the generated increase of data consumption is leading to the saturation of mobile networks. In order to provide data with high bit-rates and maintain performance as close as possible to traditional networks, the 3GPP (The 3rd Generation Partnership Project) worked on a high performance standard for mobile called Long Term Evolution (LTE). In this paper, we aim at expressing recommendations related to audio and video media profiles (selection of audio and video codecs, bit-rates, frame-rates, audio and video formats) for a typical video-calling services held over LTE/4G mobile networks. These profiles are defined according to targeted devices (smartphones, tablets), so as to ensure the best possible quality of experience (QoE). Obtained results indicate that for a CIF format (352 x 288 pixels) which is usually used for smartphones, the VP8 codec provides a better image quality than the H.264 codec for low bitrates (from 128 to 384 kbps). However sequences with high motion, H.264 in slow mode is preferred. Regarding audio, better results are globally achieved using wideband codecs offering good quality except for opus codec (at 12.2 kbps).

  11. Quality of pharmaceutical care at the pharmacy counter: patients’ experiences versus video observation

    Directory of Open Access Journals (Sweden)

    Koster ES

    2016-03-01

    Full Text Available Ellen S Koster,1 Lyda Blom,1 Marloes R Overbeeke,1 Daphne Philbert,1 Marcia Vervloet,2 Laura Koopman,2,3 Liset van Dijk2 1Division of Pharmacoepidemiology and Clinical Pharmacology, Utrecht University, the Netherlands; 2Netherlands Institute of Health Services Research (NIVEL, Utrecht, the Netherlands; 3National Health Care Institute, Diemen, the Netherlands Introduction: Consumer Quality Index questionnaires are used to assess quality of care from patients’ experiences.Objective: To provide insight into the agreement about quality of pharmaceutical care, measured both by a patient questionnaire and video observations.Methods: Pharmaceutical encounters in four pharmacies were video-recorded. Patients completed a questionnaire based upon the Consumer Quality Index Pharmaceutical Care after the encounter containing questions about patients’ experiences regarding information provision, medication counseling, and pharmacy staff’s communication style. An observation protocol was used to code the recorded encounters. Agreement between video observation and patients’ experiences was calculated.Results: In total, 109 encounters were included for analysis. For the domains “medication counseling” and “communication style”, agreement between patients’ experiences and observations was very high (>90%. Less agreement (45% was found for “information provision”, which was rated more positive by patients compared to the observations, especially for the topic, encouragement of patients’ questioning behavior.Conclusion: A questionnaire is useful to assess the quality of medication counseling and pharmacy staff’s communication style, but might be less suitable to evaluate information provision and pharmacy staff’s encouragement of patients’ questioning behavior. Although patients may believe that they have received all necessary information to use their new medicine, some information on specific instructions was not addressed during

  12. A no-reference image and video visual quality metric based on machine learning

    Science.gov (United States)

    Frantc, Vladimir; Voronin, Viacheslav; Semenishchev, Evgenii; Minkin, Maxim; Delov, Aliy

    2018-04-01

    The paper presents a novel visual quality metric for lossy compressed video quality assessment. High degree of correlation with subjective estimations of quality is due to using of a convolutional neural network trained on a large amount of pairs video sequence-subjective quality score. We demonstrate how our predicted no-reference quality metric correlates with qualitative opinion in a human observer study. Results are shown on the EVVQ dataset with comparison existing approaches.

  13. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  14. Video-based measurements for wireless capsule endoscope tracking

    Science.gov (United States)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  15. A randomized controlled trial of an educational video to improve quality of bowel preparation for colonoscopy.

    Science.gov (United States)

    Park, Jin-Seok; Kim, Min Su; Kim, HyungKil; Kim, Shin Il; Shin, Chun Ho; Lee, Hyun Jung; Lee, Won Seop; Moon, Soyoung

    2016-06-17

    High-quality bowel preparation is necessary for colonoscopy. A few studies have been conducted to investigate improvement in bowel preparation quality through patient education. However, the effect of patient education on bowel preparation has not been well studied. A randomized and prospective study was conducted. All patients received regular instruction for bowel preparation during a pre-colonoscopy visit. Those scheduled for colonoscopy were randomly assigned to view an educational video instruction (video group) on the day before the colonoscopy, or to a non-video (control) group. Qualities of bowel preparation using the Ottawa Bowel Preparation Quality scale (Ottawa score) were compared between the video and non-video groups. In addition, factors associated with poor bowel preparation were investigated. A total of 502 patients were randomized, 250 to the video group and 252 to the non-video group. The video group exhibited better bowel preparation (mean Ottawa total score: 3.03 ± 1.9) than the non-video group (4.21 ± 1.9; P educational video could improve the quality of bowel preparation in comparison with standard preparation method. Clinical Research Information Service KCT0001836 . The date of registration: March, 08(th), 2016, Retrospectively registered.

  16. Modeling the Subjective Quality of Highly Contrasted Videos Displayed on LCD With Local Backlight Dimming

    DEFF Research Database (Denmark)

    Mantel, Claire; Bech, Søren; Korhonen, Jari

    2015-01-01

    Local backlight dimming is a technology aiming at both saving energy and improving visual quality on television sets. As the rendition of the image is specified locally, the numerical signal corresponding to the displayed image needs to be computed through a model of the display. This simulated...... signal can then be used as input to objective quality metrics. The focus of this paper is on determining which characteristics of locally backlit displays influence quality assessment. A subjective experiment assessing the quality of highly contrasted videos displayed with various local backlight......-dimming algorithms is set up. Subjective results are then compared with both objective measures and objective quality metrics using different display models. The first analysis indicates that the most significant objective features are temporal variations, power consumption (probably representing leakage...

  17. Measurement and protocol for evaluating video and still stabilization systems

    Science.gov (United States)

    Cormier, Etienne; Cao, Frédéric; Guichard, Frédéric; Viard, Clément

    2013-01-01

    This article presents a system and a protocol to characterize image stabilization systems both for still images and videos. It uses a six axes platform, three being used for camera rotation and three for camera positioning. The platform is programmable and can reproduce complex motions that have been typically recorded by a gyroscope mounted on different types of cameras in different use cases. The measurement uses a single chart for still image and videos, the texture dead leaves chart. Although the proposed implementation of the protocol uses a motion platform, the measurement itself does not rely on any specific hardware. For still images, a modulation transfer function is measured in different directions and is weighted by a contrast sensitivity function (simulating the human visual system accuracy) to obtain an acutance. The sharpness improvement due to the image stabilization system is a good measurement of performance as recommended by a CIPA standard draft. For video, four markers on the chart are detected with sub-pixel accuracy to determine a homographic deformation between the current frame and a reference position. This model describes well the apparent global motion as translations, but also rotations along the optical axis and distortion due to the electronic rolling shutter equipping most CMOS sensors. The protocol is applied to all types of cameras such as DSC, DSLR and smartphones.

  18. Image quality assessment for video stream recognition systems

    Science.gov (United States)

    Chernov, Timofey S.; Razumnuy, Nikita P.; Kozharinov, Alexander S.; Nikolaev, Dmitry P.; Arlazarov, Vladimir V.

    2018-04-01

    Recognition and machine vision systems have long been widely used in many disciplines to automate various processes of life and industry. Input images of optical recognition systems can be subjected to a large number of different distortions, especially in uncontrolled or natural shooting conditions, which leads to unpredictable results of recognition systems, making it impossible to assess their reliability. For this reason, it is necessary to perform quality control of the input data of recognition systems, which is facilitated by modern progress in the field of image quality evaluation. In this paper, we investigate the approach to designing optical recognition systems with built-in input image quality estimation modules and feedback, for which the necessary definitions are introduced and a model for describing such systems is constructed. The efficiency of this approach is illustrated by the example of solving the problem of selecting the best frames for recognition in a video stream for a system with limited resources. Experimental results are presented for the system for identity documents recognition, showing a significant increase in the accuracy and speed of the system under simulated conditions of automatic camera focusing, leading to blurring of frames.

  19. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips

    OpenAIRE

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas

    2016-01-01

    Summary: Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.

  20. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips.

    Science.gov (United States)

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas

    2016-09-01

    Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.

  1. The role of optical flow in automated quality assessment of full-motion video

    Science.gov (United States)

    Harguess, Josh; Shafer, Scott; Marez, Diego

    2017-09-01

    In real-world video data, such as full-motion-video (FMV) taken from unmanned vehicles, surveillance systems, and other sources, various corruptions to the raw data is inevitable. This can be due to the image acquisition process, noise, distortion, and compression artifacts, among other sources of error. However, we desire methods to analyze the quality of the video to determine whether the underlying content of the corrupted video can be analyzed by humans or machines and to what extent. Previous approaches have shown that motion estimation, or optical flow, can be an important cue in automating this video quality assessment. However, there are many different optical flow algorithms in the literature, each with their own advantages and disadvantages. We examine the effect of the choice of optical flow algorithm (including baseline and state-of-the-art), on motionbased automated video quality assessment algorithms.

  2. Non-intrusive Packet-Layer Model for Monitoring Video Quality of IPTV Services

    Science.gov (United States)

    Yamagishi, Kazuhisa; Hayashi, Takanori

    Developing a non-intrusive packet-layer model is required to passively monitor the quality of experience (QoE) during service. We propose a packet-layer model that can be used to estimate the video quality of IPTV using quality parameters derived from transmitted packet headers. The computational load of the model is lighter than that of the model that takes video signals and/or video-related bitstream information such as motion vectors as input. This model is applicable even if the transmitted bitstream information is encrypted because it uses transmitted packet headers rather than bitstream information. For developing the model, we conducted three extensive subjective quality assessments for different encoders and decoders (codecs), and video content. Then, we modeled the subjective video quality assessment characteristics based on objective features affected by coding and packet loss. Finally, we verified the model's validity by applying our model to unknown data sets different from training data sets used above.

  3. Effects of music and music video interventions on sleep quality: A randomized controlled trial in adults with sleep disturbances.

    Science.gov (United States)

    Huang, Chiung-Yu; Chang, En-Ting; Hsieh, Yuan-Mei; Lai, Hui-Ling

    2017-10-01

    The present study aimed to compare the effects of music and music video interventions on objective and subjective sleep quality in adults with sleep disturbances. A randomized controlled trial was performed on 71 adults who were recruited from the outpatient department of a hospital with 1100 beds and randomly assigned to the control, music, and music video groups. During the 4 test days (Days 2-5), for 30min before nocturnal sleep, the music group listened to Buddhist music and the music video group watched Buddhist music videos. They were instructed to not listen/watch to the music/MV on the first night (pretest, Day 1) and the final night (Day 6). The control group received no intervention. Sleep was assessed using a one-channel electroencephalography machine in their homes and self-reported questionnaires. The music and music video interventions had no effect on any objective sleep parameters, as measured using electroencephalography. However, the music group had significantly longer subjective total sleep time than the music video group did (Wald χ 2 =6.23, p=0.04). Our study results increase knowledge regarding music interventions for sleep quality in adults with sleep disturbances. This study suggested that more research is required to strengthen the scientific knowledge of the effects of music intervention on sleep quality in adults with sleep disturbances. (ISRCTN94971645). Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Digital video image processing applications to two phase flow measurements

    International Nuclear Information System (INIS)

    Biscos, Y.; Bismes, F.; Hebrard, P.; Lavergne, G.

    1987-01-01

    Liquid spraying is common in various fields (combustion, cooling of hot surfaces, spray drying,...). For two phase flows modeling, it is necessary to test elementary laws (vaporizing drops, equation of motion of drops or bubbles, heat transfer..). For example, the knowledge of the laws related to the behavior of vaporizing liquid drop in a hot airstream and impinging drops on a hot surface is important for two phase flow modeling. In order to test these different laws in elementary cases, the authors developed different measurement techniques, associating video and microcomputers. The test section (built in perpex or glass) is illuminated with a thin sheet of light generated by a 15mW He-Ne laser and appropriate optical arrangement. Drops, bubbles or liquid film are observed at right angle by a video camera synchronised with a microcomputer either directly or with an optical device (lens, telescope, microscope) providing sufficient magnification. Digitizing the video picture in real time associated with an appropriate numerical treatment allows to obtain, in a non interfering way, a lot of informations relative to the pulverisation and the vaporization as function of space and time (drop size distribution; Sauter mean diameter as function of main flow parameters: air velocity, surface tension, temperature; isoconcentration curves, size evolution relative to vaporizing drops, film thickness evolution spreading on a hot surface...)

  5. Measuring physical inactivity: do current measures provide an accurate view of "sedentary" video game time?

    Science.gov (United States)

    Fullerton, Simon; Taylor, Anne W; Dal Grande, Eleonora; Berry, Narelle

    2014-01-01

    Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames) can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n = 2026) were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children's video game time. A substantial proportion of time that would usually be classified as "sedentary" may actually be spent participating in light to moderate physical activity.

  6. Measuring quality progress

    Science.gov (United States)

    Lambert, Larry D.

    The study by the American Productivity & Quality Center (APQC) was commissioned by Loral Space Information Systems, Inc. and the National Aeronautics and Space Administration (NASA) to evaluate internal assessment systems. APQC benchmarked approaches to the internal assessment of quality management systems in three phases. The first phase included work conducted for the International Benchmarking Clearinghouse (IBC) and consisted of an in-depth analysis of the 1991 Malcolm Baldrige National Quality Award criteria. The second phase was also performed for the IBC and compared the 1991 award criteria among the following quality awards: Deming Prize, Malcolm Baldrige National Quality Award, The President's Award for Quality and Productivity Improvement, The NASA Excellence Award (The George M. Lowe Trophy) for Quality and Productivity Improvement and the Shigeo Shingo Award for Excellence in Manufacturing. The third phase compared the internal implementation approaches of 23 companies selected from American industry for their recognized, formal assessment systems.

  7. Measuring quality progress

    Science.gov (United States)

    Lambert, Larry D.

    1992-01-01

    The study by the American Productivity & Quality Center (APQC) was commissioned by Loral Space Information Systems, Inc. and the National Aeronautics and Space Administration (NASA) to evaluate internal assessment systems. APQC benchmarked approaches to the internal assessment of quality management systems in three phases. The first phase included work conducted for the International Benchmarking Clearinghouse (IBC) and consisted of an in-depth analysis of the 1991 Malcolm Baldrige National Quality Award criteria. The second phase was also performed for the IBC and compared the 1991 award criteria among the following quality awards: Deming Prize, Malcolm Baldrige National Quality Award, The President's Award for Quality and Productivity Improvement, The NASA Excellence Award (The George M. Lowe Trophy) for Quality and Productivity Improvement and the Shigeo Shingo Award for Excellence in Manufacturing. The third phase compared the internal implementation approaches of 23 companies selected from American industry for their recognized, formal assessment systems.

  8. Measuring health care process quality with software quality measures.

    Science.gov (United States)

    Yildiz, Ozkan; Demirörs, Onur

    2012-01-01

    Existing quality models focus on some specific diseases, clinics or clinical areas. Although they contain structure, process, or output type measures, there is no model which measures quality of health care processes comprehensively. In addition, due to the not measured overall process quality, hospitals cannot compare quality of processes internally and externally. To bring a solution to above problems, a new model is developed from software quality measures. We have adopted the ISO/IEC 9126 software quality standard for health care processes. Then, JCIAS (Joint Commission International Accreditation Standards for Hospitals) measurable elements were added to model scope for unifying functional requirements. Assessment (diagnosing) process measurement results are provided in this paper. After the application, it was concluded that the model determines weak and strong aspects of the processes, gives a more detailed picture for the process quality, and provides quantifiable information to hospitals to compare their processes with multiple organizations.

  9. Summarization of Surveillance Video Sequences Using Face Quality Assessment

    DEFF Research Database (Denmark)

    Nasrollahi, Kamal; Moeslund, Thomas B.; Rahmati, Mohammad

    2011-01-01

    Constant working surveillance cameras in public places, such as airports and banks, produce huge amount of video data. Faces in such videos can be extracted in real time. However, most of these detected faces are either redundant or useless. Redundant information adds computational costs to facial...

  10. Enabling 'togetherness' in high-quality domestic video conferencing

    NARCIS (Netherlands)

    Kegel, I.; Cesar, P.; Jansen, J.; Bulterman, D.C.A.; Stevens, T.; Kort, J.; Färber, N.

    2012-01-01

    Low-cost video conferencing systems have provided an existence proof for the value of video communication in a home setting. At the same time, current systems have a number of fundamental limitations that inhibit more general social interactions among multiple groups of participants. In our work, we

  11. Enabling 'Togetherness' in High-Quality Domestic Video Conferencing

    NARCIS (Netherlands)

    I. Kegel; P.S. Cesar Garcia (Pablo Santiago); A.J. Jansen (Jack); D.C.A. Bulterman (Dick); J. Kort; T. Stevens; N. Farber

    2012-01-01

    htmlabstractLow-cost video conferencing systems have provided an existence proof for the value of video communication in a home setting. At the same time, current systems have a number of fundamental limitations that inhibit more general social interactions among multiple groups of participants. In

  12. No-Reference Video Quality Assessment Based on Statistical Analysis in 3D-DCT Domain.

    Science.gov (United States)

    Li, Xuelong; Guo, Qun; Lu, Xiaoqiang

    2016-05-13

    It is an important task to design models for universal no-reference video quality assessment (NR-VQA) in multiple video processing and computer vision applications. However, most existing NR-VQA metrics are designed for specific distortion types which are not often aware in practical applications. A further deficiency is that the spatial and temporal information of videos is hardly considered simultaneously. In this paper, we propose a new NR-VQA metric based on the spatiotemporal natural video statistics (NVS) in 3D discrete cosine transform (3D-DCT) domain. In the proposed method, a set of features are firstly extracted based on the statistical analysis of 3D-DCT coefficients to characterize the spatiotemporal statistics of videos in different views. These features are used to predict the perceived video quality via the efficient linear support vector regression (SVR) model afterwards. The contributions of this paper are: 1) we explore the spatiotemporal statistics of videos in 3DDCT domain which has the inherent spatiotemporal encoding advantage over other widely used 2D transformations; 2) we extract a small set of simple but effective statistical features for video visual quality prediction; 3) the proposed method is universal for multiple types of distortions and robust to different databases. The proposed method is tested on four widely used video databases. Extensive experimental results demonstrate that the proposed method is competitive with the state-of-art NR-VQA metrics and the top-performing FR-VQA and RR-VQA metrics.

  13. No-Reference Video Quality Assessment Model for Distortion Caused by Packet Loss in the Real-Time Mobile Video Services

    Directory of Open Access Journals (Sweden)

    Jiarun Song

    2014-01-01

    Full Text Available Packet loss will make severe errors due to the corruption of related video data. For most video streams, because the predictive coding structures are employed, the transmission errors in one frame will not only cause decoding failure of itself at the receiver side, but also propagate to its subsequent frames along the motion prediction path, which will bring a significant degradation of end-to-end video quality. To quantify the effects of packet loss on video quality, a no-reference objective quality assessment model is presented in this paper. Considering the fact that the degradation of video quality significantly relies on the video content, the temporal complexity is estimated to reflect the varying characteristic of video content, using the macroblocks with different motion activities in each frame. Then, the quality of the frame affected by the reference frame loss, by error propagation, or by both of them is evaluated, respectively. Utilizing a two-level temporal pooling scheme, the video quality is finally obtained. Extensive experimental results show that the video quality estimated by the proposed method matches well with the subjective quality.

  14. Heart rate measurement based on face video sequence

    Science.gov (United States)

    Xu, Fang; Zhou, Qin-Wu; Wu, Peng; Chen, Xing; Yang, Xiaofeng; Yan, Hong-jian

    2015-03-01

    This paper proposes a new non-contact heart rate measurement method based on photoplethysmography (PPG) theory. With this method we can measure heart rate remotely with a camera and ambient light. We collected video sequences of subjects, and detected remote PPG signals through video sequences. Remote PPG signals were analyzed with two methods, Blind Source Separation Technology (BSST) and Cross Spectral Power Technology (CSPT). BSST is a commonly used method, and CSPT is used for the first time in the study of remote PPG signals in this paper. Both of the methods can acquire heart rate, but compared with BSST, CSPT has clearer physical meaning, and the computational complexity of CSPT is lower than that of BSST. Our work shows that heart rates detected by CSPT method have good consistency with the heart rates measured by a finger clip oximeter. With good accuracy and low computational complexity, the CSPT method has a good prospect for the application in the field of home medical devices and mobile health devices.

  15. 3D Scan-Based Wavelet Transform and Quality Control for Video Coding

    Directory of Open Access Journals (Sweden)

    Parisot Christophe

    2003-01-01

    Full Text Available Wavelet coding has been shown to achieve better compression than DCT coding and moreover allows scalability. 2D DWT can be easily extended to 3D and thus applied to video coding. However, 3D subband coding of video suffers from two drawbacks. The first is the amount of memory required for coding large 3D blocks; the second is the lack of temporal quality due to the sequence temporal splitting. In fact, 3D block-based video coders produce jerks. They appear at blocks temporal borders during video playback. In this paper, we propose a new temporal scan-based wavelet transform method for video coding combining the advantages of wavelet coding (performance, scalability with acceptable reduced memory requirements, no additional CPU complexity, and avoiding jerks. We also propose an efficient quality allocation procedure to ensure a constant quality over time.

  16. Quality Assessment of Adaptive Bitrate Videos using Image Metrics and Machine Learning

    DEFF Research Database (Denmark)

    Søgaard, Jacob; Forchhammer, Søren; Brunnström, Kjell

    2015-01-01

    Adaptive bitrate (ABR) streaming is widely used for distribution of videos over the internet. In this work, we investigate how well we can predict the quality of such videos using well-known image metrics, information about the bitrate levels, and a relatively simple machine learning method...

  17. Interactional Quality Depicted in Infant and Toddler Videos: Where Are the Interactions?

    Science.gov (United States)

    Fenstermacher, Susan K.; Barr, Rachel; Brey, Elizabeth; Pempek, Tiffany A.; Ryan, Maureen; Calvert, Sandra L.; Shwery, Clay E.; Linebarger, Deborah

    2010-01-01

    This study examined the social-emotional content and the quality of social interactions depicted in a sample of 58 DVDs marketed towards infants and toddlers. Infant-directed videos rarely used social interactions between caregiver and child or between peers to present content. Even when videos explicitly targeted social-emotional content,…

  18. Quality measurement in diabetes care.

    Science.gov (United States)

    Leas, Brian F; Berman, Bettina; Kash, Kathryn M; Crawford, Albert G; Toner, Richard W; Goldfarb, Neil I; Nash, David B

    2009-10-01

    This study aimed to evaluate diabetes quality measurement efforts, assess their strengths and areas for improvement, and identify gaps not adequately addressed by these measures. We conducted an environmental scan of diabetes quality measures, focusing on metrics included in the National Quality Measures Clearinghouse or promulgated by leading measurement organizations. Key informant interviews were also completed with thought leaders who develop, promote, and use quality measures. The environmental scan identified 146 distinct measures spanning 31 clinical processes or outcomes. This suggests a measurement system that is both redundant and inconsistent, with many different measures assessing the same clinical indicators. Interviewees believe that current diabetes measurement efforts are excessively broad and complex and expressed a need for better harmonization of these measures. Several gaps were also found, including a lack of measures focusing on population health, structural elements of health care, and prevention of diabetes.

  19. The Effect of Signal Quality and Contiguous Word of Mouth on Customer Acquisition for a Video-on-Demand Service

    OpenAIRE

    Sungjoon Nam; Puneet Manchanda; Pradeep K. Chintagunta

    2010-01-01

    This paper documents the existence and magnitude of contiguous word-of-mouth effects of signal quality of a video-on-demand (VOD) service on customer acquisition. We operationalize contiguous word-of-mouth effect based on geographic proximity and use behavioral data to quantify the effect. The signal quality for this VOD service is exogenously determined, objectively measured, and spatially uncorrelated. Furthermore, it is unobserved to the potential subscriber and is revealed postadoption. F...

  20. Video Monitoring a Simulation-Based Quality Improvement Program in Bihar, India.

    Science.gov (United States)

    Dyer, Jessica; Spindler, Hilary; Christmas, Amelia; Shah, Malay Bharat; Morgan, Melissa; Cohen, Susanna R; Sterne, Jason; Mahapatra, Tanmay; Walker, Dilys

    2018-04-01

    Simulation-based training has become an accepted clinical training andragogy in high-resource settings with its use increasing in low-resource settings. Video recordings of simulated scenarios are commonly used by facilitators. Beyond using the videos during debrief sessions, researchers can also analyze the simulation videos to quantify technical and nontechnical skills during simulated scenarios over time. Little is known about the feasibility and use of large-scale systems to video record and analyze simulation and debriefing data for monitoring and evaluation in low-resource settings. This manuscript describes the process of designing and implementing a large-scale video monitoring system. Mentees and Mentors were consented and all simulations and debriefs conducted at 320 Primary Health Centers (PHCs) were video recorded. The system design, number of video recordings, and inter-rater reliability of the coded videos were assessed. The final dataset included a total of 11,278 videos. Overall, a total of 2,124 simulation videos were coded and 183 (12%) were blindly double-coded. For the double-coded sample, the average inter-rater reliability (IRR) scores were 80% for nontechnical skills, and 94% for clinical technical skills. Among 4,450 long debrief videos received, 216 were selected for coding and all were double-coded. Data quality of simulation videos was found to be very good in terms of recorded instances of "unable to see" and "unable to hear" in Phases 1 and 2. This study demonstrates that video monitoring systems can be effectively implemented at scale in resource limited settings. Further, video monitoring systems can play several vital roles within program implementation, including monitoring and evaluation, provision of actionable feedback to program implementers, and assurance of program fidelity.

  1. Service Quality Measurements: A Review

    OpenAIRE

    Ali Ramezani Ghotbabadi; Setareh Feiz; Rohaizat Baharun

    2015-01-01

    Service quality measurement is one of the significant measurement tools for firms to understand consumers’ needs and wants by analyzing the experience of consumers and customers’ satisfaction on the services provided. Although there is no general agreement on one particular model used as the measurement of service quality perceived, there are some effective models offered by researchers during decades of study in this area. In the recent years, researchers believe that service quality is mult...

  2. Educational Colonoscopy Video Enhances Bowel Preparation Quality and Comprehension in an Inner City Population.

    Science.gov (United States)

    Pillai, Ajish; Menon, Radha; Oustecky, David; Ahmad, Asyia

    2017-07-24

    Quality of bowel preparation and patient knowledge remains a major barrier for completing colorectal cancer screening. Few studies have tested unique ways to impact patient understanding centering on interactive computer programs, pictures, and brochures. Two studies explored instructional videos but focused on patient compliance and anxiety as endpoints. Furthermore, excessive video length and content may limit their impact on a broad patient population. No study so far has studied a video's impact on preparation quality and patient understanding of the colonoscopy procedure. We conducted a single blinded prospective study of inner city patients presenting for a first time screening colonoscopy. During their initial visit patients were randomized to watch an instructional colonoscopy video or a video discussing gastroesophageal reflux disease (GERD). All patients watched a 6 minutes long video with the same spokesperson, completed a demographic questionnaire (Supplemental Digital Content 1, http://links.lww.com/JCG/A352) and were enrolled only if screened within 30 days of their visit. On the day of the colonoscopy, patients completed a 14 question quiz of their knowledge. Blinded endoscopist graded patient preparations based on the Ottawa scale. All authors had access to the study data and reviewed and approved the final manuscript. Among the 104 subjects enrolled in the study, 56 were in the colonoscopy video group, 48 were in GERD video group, and 12 were excluded. Overall, 48% were male and 52% female; 90% of patients had less than a high school education, 76% were African American, and 67% used a 4 L split-dose preparation. There were no differences between either video group with regard to any of the above categories. Comparisons between the 2 groups revealed that the colonoscopy video group had significantly better Ottawa bowel preparation score (4.77 vs. 6.85; P=0.01) than the GERD video group. The colonoscopy video group also had less-inadequate repeat

  3. Performance of biometric quality measures.

    Science.gov (United States)

    Grother, Patrick; Tabassi, Elham

    2007-04-01

    We document methods for the quantitative evaluation of systems that produce a scalar summary of a biometric sample's quality. We are motivated by a need to test claims that quality measures are predictive of matching performance. We regard a quality measurement algorithm as a black box that converts an input sample to an output scalar. We evaluate it by quantifying the association between those values and observed matching results. We advance detection error trade-off and error versus reject characteristics as metrics for the comparative evaluation of sample quality measurement algorithms. We proceed this with a definition of sample quality, a description of the operational use of quality measures. We emphasize the performance goal by including a procedure for annotating the samples of a reference corpus with quality values derived from empirical recognition scores.

  4. On subjective quality assessment of adaptive video streaming via crowdsourcing and laboratory based experiments

    DEFF Research Database (Denmark)

    Søgaard, Jacob; Shahid, Muhammad; Pokhrel, Jeevan

    2017-01-01

    Video streaming services are offered over the Internet and since the service providers do not have full control over the network conditions all the way to the end user, streaming technologies have been developed to maintain the quality of service in these varying network conditions i.e. so called...... adaptive video streaming. In order to cater for users' Quality of Experience (QoE) requirements, HTTP based adaptive streaming solutions of video services have become popular. However, the keys to ensure the users a good QoE with this technology is still not completely understood. User QoE feedback...

  5. Quality Assurance of Chemical Measurements.

    Science.gov (United States)

    Taylor, John K.

    1981-01-01

    Reviews aspects of quality control (methods to control errors) and quality assessment (verification that systems are operating within acceptable limits) including an analytical measurement system, quality control by inspection, control charts, systematic errors, and use of SRMs, materials for which properties are certified by the National Bureau…

  6. The influence of motion quality on responses towards video playback stimuli

    Directory of Open Access Journals (Sweden)

    Emma Ware

    2015-07-01

    Full Text Available Visual motion, a critical cue in communication, can be manipulated and studied using video playback methods. A primary concern for the video playback researcher is the degree to which objects presented on video appear natural to the non-human subject. Here we argue that the quality of motion cues on video, as determined by the video's image presentation rate (IPR, are of particular importance in determining a subject's social response behaviour. We present an experiment testing the effect of variations in IPR on pigeon (Columbia livia response behaviour towards video images of courting opposite sex partners. Male and female pigeons were presented with three video playback stimuli, each containing a different social partner. Each stimulus was then modified to appear at one of three IPRs: 15, 30 or 60 progressive (p frames per second. The results showed that courtship behaviour became significantly longer in duration as IPR increased. This finding implies that the IPR significantly affects the perceived quality of motion cues impacting social behaviour. In males we found that the duration of courtship also depended on the social partner viewed and that this effect interacted with the effects of IPR on behaviour. Specifically, the effect of social partner reached statistical significance only when the stimuli were displayed at 60 p, demonstrating the potential for erroneous results when insufficient IPRs are used. In addition to demonstrating the importance of IPR in video playback experiments, these findings help to highlight and describe the role of visual motion processing in communication behaviour.

  7. Subjective Quality Assessment of H.264/AVC Video Streaming with Packet Losses

    Directory of Open Access Journals (Sweden)

    Naccari Matteo

    2011-01-01

    Full Text Available Research in the field of video quality assessment relies on the availability of subjective scores, collected by means of experiments in which groups of people are asked to rate the quality of video sequences. The availability of subjective scores is fundamental to enable validation and comparative benchmarking of the objective algorithms that try to predict human perception of video quality by automatically analyzing the video sequences, in a way to support reproducible and reliable research results. In this paper, a publicly available database of subjective quality scores and corrupted video sequences is described. The scores refer to 156 sequences at CIF and 4CIF spatial resolutions, encoded with H.264/AVC and corrupted by simulating the transmission over an error-prone network. The subjective evaluation has been performed by 40 subjects at the premises of two academic institutions, in standard-compliant controlled environments. In order to support reproducible research in the field of full-reference, reduced-reference, and no-reference video quality assessment algorithms, both the uncompressed files and the H.264/AVC bitstreams, as well as the packet loss patterns, have been made available to the research community.

  8. A time-varying subjective quality model for mobile streaming videos with stalling events

    Science.gov (United States)

    Ghadiyaram, Deepti; Pan, Janice; Bovik, Alan C.

    2015-09-01

    Over-the-top mobile video streaming is invariably influenced by volatile network conditions which cause playback interruptions (stalling events), thereby impairing users' quality of experience (QoE). Developing models that can accurately predict users' QoE could enable the more efficient design of quality-control protocols for video streaming networks that reduce network operational costs while still delivering high-quality video content to the customers. Existing objective models that predict QoE are based on global video features, such as the number of stall events and their lengths, and are trained and validated on a small pool of ad hoc video datasets, most of which are not publicly available. The model we propose in this work goes beyond previous models as it also accounts for the fundamental effect that a viewer's recent level of satisfaction or dissatisfaction has on their overall viewing experience. In other words, the proposed model accounts for and adapts to the recency, or hysteresis effect caused by a stall event in addition to accounting for the lengths, frequency of occurrence, and the positions of stall events - factors that interact in a complex way to affect a user's QoE. On the recently introduced LIVE-Avvasi Mobile Video Database, which consists of 180 distorted videos of varied content that are afflicted solely with over 25 unique realistic stalling events, we trained and validated our model to accurately predict the QoE, attaining standout QoE prediction performance.

  9. AMOS Seeing Quality Measurements.

    Science.gov (United States)

    1976-01-01

    Measurement Atmosphere Turbulence Propagation Observatory Acoustic Sounder Maui Optical Station Astronomy Microthermal Probe TEAL BLUE Degradation...presence of the site structures. Instruments used were an acoustic sounder (to probe the altitudes of 100 to 1000 ft), fine- wire microthermal probes...responsibility during the experiment for the microthermal probes. The report itself, while compiled and edited at RADC, may be considered as coming from

  10. Intelligent Packet Shaper to Avoid Network Congestion for Improved Streaming Video Quality at Clients

    DEFF Research Database (Denmark)

    Kaul, Manohar; Khosla, Rajiv; Mitsukura, Y

    2003-01-01

    of this intelligent traffic-shaping algorithm on the underlying network real time packet traffic and the eradication of unwanted abruption in the streaming video qualiy. This paper concluded from the end results of the simulation that neural networks are a very superior means of modeling real-time traffic......This paper proposes a traffic shaping algorithm based on neural networks, which adapts to a network over which streaming video is being transmitted. The purpose of this intelligent shaper is to eradicate all traffic congestion and improve the end-user's video quality. It possesses the capability...

  11. Investigating the quality of video consultations performed using fourth generation (4G) mobile telecommunications.

    Science.gov (United States)

    Caffery, Liam J; Smith, Anthony C

    2015-09-01

    The use of fourth-generation (4G) mobile telecommunications to provide real-time video consultations were investigated in this study with the aims of determining if 4G is a suitable telecommunications technology; and secondly, to identify if variation in perceived audio and video quality were due to underlying network performance. Three patient end-points that used 4G Internet connections were evaluated. Consulting clinicians recorded their perception of audio and video quality using the International Telecommunications Union scales during clinics with these patient end-points. These scores were used to calculate a mean opinion score (MOS). The network performance metrics were obtained for each session and the relationships between these metrics and the session's quality scores were tested. Clinicians scored the quality of 50 hours of video consultations, involving 36 clinic sessions. The MOS for audio was 4.1 ± 0.62 and the MOS for video was 4.4 ± 0.22. Image impairment and effort to listen were also rated favourably. There was no correlation between audio or video quality and the network metrics of packet loss or jitter. These findings suggest that 4G networks are an appropriate telecommunication technology to deliver real-time video consultations. Variations in quality scores observed during this study were not explained by the packet loss and jitter in the underlying network. Before establishing a telemedicine service, the performance of the 4G network should be assessed at the location of the proposed service. This is due to known variability in performance of 4G networks. © The Author(s) 2015.

  12. Measurement of Submerged Oil/Gas Leaks using ROV Video

    Science.gov (United States)

    Shaffer, Franklin; de Vera, Giorgio; Lee, Kenneth; Savas, Ömer

    2013-11-01

    Drilling for oil or gas in the Gulf of Mexico is increasing rapidly at depths up to three miles. The National Commission on the Deepwater Horizon Oil Leak concluded that inaccurate estimates of the leak rate from the Deepwater Horizon caused an inadequate response and attempts to cap the leak to fail. The first response to a submerged oil/gas leak will be to send a Remotely Operated Vehicle (ROV) down to view the leak. During the response to the Deepwater Horizon crisis, the authors Savas and Shaffer were members of the Flow Rate Technical Group's Plume Team who used ROV video to develop the FRTG's first official estimates of the oil leak rate. Savas and Shaffer developed an approach using the larger, faster jet features (e.g., turbulent eddies, vortices, entrained particles) in the near-field developing zone to measure discharge rates. The authors have since used the Berkeley Tow Tank to test this approach on submerged dye-colored water jets and compressed air jets. Image Correlation Velocimetry has been applied to measure the velocity of visible features. Results from tests in the Berkeley Tow Tank and submerged oil jets in the OHMSETT facility will be presented.

  13. The Measurement of Intelligence in the XXI Century using Video Games.

    Science.gov (United States)

    Quiroga, M A; Román, F J; De La Fuente, J; Privado, J; Colom, R

    2016-12-05

    This paper reviews the use of video games for measuring intelligence differences and reports two studies analyzing the relationship between intelligence and performance on a leisure video game. In the first study, the main focus was to design an Intelligence Test using puzzles from the video game. Forty-seven young participants played "Professor Layton and the curious village"® for a maximum of 15 hours and completed a set of intelligence standardized tests. Results show that the time required for completing the game interacts with intelligence differences: the higher the intelligence, the lower the time (d = .91). Furthermore, a set of 41 puzzles showed excellent psychometric properties. The second study, done seven years later, confirmed the previous findings. We finally discuss the pros and cons of video games as tools for measuring cognitive abilities with commercial video games, underscoring that psychologists must develop their own intelligence video games and delineate their key features for the measurement devices of next generation.

  14. Video quality-of-service for consumer terminals : a novel system for programmable components

    NARCIS (Netherlands)

    Hentschel, C.; Bril, R.J.; Chen, Y.; Braspenning, R.A.C.; Lan, T-H.

    2003-01-01

    Future consumer terminals will be more and more based on programmable platforms instead of only dedicated hardware. Novel scalable video algorithm (SVA) software modules trade off resource usage against quality of the output signal. SVAs together with a strategy manager and a quality-of-service

  15. Impairment-Factor-Based Audiovisual Quality Model for IPTV: Influence of Video Resolution, Degradation Type, and Content Type

    Directory of Open Access Journals (Sweden)

    Garcia MN

    2011-01-01

    Full Text Available This paper presents an audiovisual quality model for IPTV services. The model estimates the audiovisual quality of standard and high definition video as perceived by the user. The model is developed for applications such as network planning and packet-layer quality monitoring. It mainly covers audio and video compression artifacts and impairments due to packet loss. The quality tests conducted for model development demonstrate a mutual influence of the perceived audio and video quality, and the predominance of the video quality for the overall audiovisual quality. The balance between audio quality and video quality, however, depends on the content, the video format, and the audio degradation type. The proposed model is based on impairment factors which quantify the quality-impact of the different degradations. The impairment factors are computed from parameters extracted from the bitstream or packet headers. For high definition video, the model predictions show a correlation with unknown subjective ratings of 95%. For comparison, we have developed a more classical audiovisual quality model which is based on the audio and video qualities and their interaction. Both quality- and impairment-factor-based models are further refined by taking the content-type into account. At last, the different model variants are compared with modeling approaches described in the literature.

  16. Venous Thromboembolism Quality Measures Fail to Accurately Measure Quality.

    Science.gov (United States)

    Lau, Brandyn D; Streiff, Michael B; Pronovost, Peter J; Haut, Elliott R

    2018-03-20

    Venous thromboembolism (VTE) is 1 of the most common causes of preventable harm for patients in hospitals. Consequently, the Joint Commission, the Centers for Medicare and Medicaid Services, the Agency for Healthcare Research and Quality, the United Kingdom Care Quality Commission, the Australian Commission on Safety and Quality in Health Care, the Maryland Health Services Cost Review Commission, and the American College of Surgeons have prioritized measuring and reporting VTE outcomes with the goal of reducing the incidence of and preventable harm from VTE. We developed a rubric for defect-free VTE prevention, graded each organizational VTE quality measure, and found that none of the current VTE-related quality measures adequately characterizes VTE prevention efforts or outcomes in hospitalized patients. Effective VTE prevention is multifactorial: clinicians must assess patients' risk for VTE and prescribe therapy appropriate for each patient's risk profile, patients must accept the prescribed therapy, and nurses must administer the therapy as prescribed. First, an ideal, defect-free VTE prevention process measure requires: (1) documentation of a standardized VTE risk assessment; (2) prescription of optimal, risk-appropriate VTE prophylaxis; and (3) administration of all risk-appropriate VTE prophylaxis as prescribed. Second, an ideal VTE outcome measure should define potentially preventable VTE as VTE that developed in patients who experienced any VTE prevention process failures. © 2018 American Heart Association, Inc.

  17. Training value of laparoscopic colorectal videos on the World Wide Web: a pilot study on the educational quality of laparoscopic right hemicolectomy videos.

    Science.gov (United States)

    Celentano, V; Browning, M; Hitchins, C; Giglio, M C; Coleman, M G

    2017-11-01

    Instructive laparoscopy videos with appropriate exposition could be ideal for initial training in laparoscopic surgery, but unfortunately there are no guidelines for annotating these videos or agreed methods to measure the educational content and the safety of the procedure presented. Aim of this study is to systematically search the World Wide Web to determine the availability of laparoscopic colorectal surgery videos and to objectively establish their potential training value. A search for laparoscopic right hemicolectomy videos was performed on the three most used English language web search engines Google.com, Bing.com, and Yahoo.com; moreover, a survey among 25 local trainees was performed to identify additional websites for inclusion. All laparoscopic right hemicolectomy videos with an English language title were included. Videos of open surgery, single incision laparoscopic surgery, robotic, and hand-assisted surgery were excluded. The safety of the demonstrated procedure was assessed with a validated competency assessment tool specifically designed for laparoscopic colorectal surgery and data on the educational content of the video were extracted. Thirty-one websites were identified and 182 surgical videos were included. One hundred and seventy-three videos (95%) detailed the year of publication; this demonstrated a significant increase in the number of videos published per year from 2009. Characteristics of the patient were rarely presented, only 10 videos (5.4%) reported operating time and only 6 videos (3.2%) reported 30-day morbidity; 34 videos (18.6%) underwent a peer-review process prior to publication. Formal case presentation, the presence of audio narration, the use of diagrams, and snapshots and a step-by-step approach are all characteristics of peer-reviewed videos but no significant difference was found in the safety of the procedure. Laparoscopic videos can be a useful adjunct to operative training. There is a large and increasing amount of

  18. Reliability and Validity of the Behavioral Addiction Measure for Video Gaming.

    Science.gov (United States)

    Sanders, James L; Williams, Robert J

    2016-01-01

    Most tests of video game addiction have weak construct validity and limited ability to correctly identify people in denial. The purpose of the present research was to investigate the reliability and validity of a new test of video game addiction (Behavioral Addiction Measure-Video Gaming [BAM-VG]) that was developed in part to address these deficiencies. Regular adult video gamers (n = 506) were recruited from a Canadian online panel and completed a survey containing three measures of excessive video gaming (BAM-VG; DSM-5 criteria for Internet Gaming Disorder [IGD]; and the IGD-20), as well as questions concerning extensiveness of video game involvement and self-report of problems associated with video gaming. One month later, they were reassessed for the purposes of establishing test-retest reliability. The BAM-VG demonstrated good internal consistency as well as 1 month test-retest reliability. Criterion-related validity was demonstrated by significant correlations with the following: time spent playing, self-identification of video game problems, and scores on other instruments designed to assess video game addiction (DSM-5 IGD, IGD-20). Consistent with the theory, principal component analysis identified two components underlying the BAM-VG that roughly correspond with impaired control and significant negative consequences deriving from this impaired control. Together with its excellent construct validity and other technical features, the BAM-VG represents a reliable and valid test of video game addiction.

  19. Objective analysis of image quality of video image capture systems

    Science.gov (United States)

    Rowberg, Alan H.

    1990-07-01

    As Picture Archiving and Communication System (PACS) technology has matured, video image capture has become a common way of capturing digital images from many modalities. While digital interfaces, such as those which use the ACR/NEMA standard, will become more common in the future, and are preferred because of the accuracy of image transfer, video image capture will be the dominant method in the short term, and may continue to be used for some time because of the low cost and high speed often associated with such devices. Currently, virtually all installed systems use methods of digitizing the video signal that is produced for display on the scanner viewing console itself. A series of digital test images have been developed for display on either a GE CT9800 or a GE Signa MRI scanner. These images have been captured with each of five commercially available image capture systems, and the resultant images digitally transferred on floppy disk to a PC1286 computer containing Optimast' image analysis software. Here the images can be displayed in a comparative manner for visual evaluation, in addition to being analyzed statistically. Each of the images have been designed to support certain tests, including noise, accuracy, linearity, gray scale range, stability, slew rate, and pixel alignment. These image capture systems vary widely in these characteristics, in addition to the presence or absence of other artifacts, such as shading and moire pattern. Other accessories such as video distribution amplifiers and noise filters can also add or modify artifacts seen in the captured images, often giving unusual results. Each image is described, together with the tests which were performed using them. One image contains alternating black and white lines, each one pixel wide, after equilibration strips ten pixels wide. While some systems have a slew rate fast enough to track this correctly, others blur it to an average shade of gray, and do not resolve the lines, or give

  20. Network analysis on skype end-to-end video quality

    NARCIS (Netherlands)

    Exarchakos, Georgios; Druda, Luca; Menkovski, Vlado; Liotta, Antonio

    2015-01-01

    Purpose – This paper aims to argue on the efficiency of Quality of Service (QoS)-based adaptive streamingwith regards to perceived quality Quality of Experience (QoE). Although QoS parameters are extensivelyused even by high-end adaptive streaming algorithms, achieved QoE fails to justify their use

  1. VQone MATLAB toolbox: A graphical experiment builder for image and video quality evaluations: VQone MATLAB toolbox.

    Science.gov (United States)

    Nuutinen, Mikko; Virtanen, Toni; Rummukainen, Olli; Häkkinen, Jukka

    2016-03-01

    This article presents VQone, a graphical experiment builder, written as a MATLAB toolbox, developed for image and video quality ratings. VQone contains the main elements needed for the subjective image and video quality rating process. This includes building and conducting experiments and data analysis. All functions can be controlled through graphical user interfaces. The experiment builder includes many standardized image and video quality rating methods. Moreover, it enables the creation of new methods or modified versions from standard methods. VQone is distributed free of charge under the terms of the GNU general public license and allows code modifications to be made so that the program's functions can be adjusted according to a user's requirements. VQone is available for download from the project page (http://www.helsinki.fi/psychology/groups/visualcognition/).

  2. A Survey of Standardized Approaches towards the Quality of Experience Evaluation for Video Services: An ITU Perspective

    Directory of Open Access Journals (Sweden)

    Debajyoti Pal

    2018-01-01

    Full Text Available Over the past few years there has been an exponential increase in the amount of multimedia data being streamed over the Internet. At the same time, we are also witnessing a change in the way quality of any particular service is interpreted, with more emphasis being given to the end-users. Thus, silently there has been a paradigm shift from the traditional Quality of Service approach (QoS towards a Quality of Experience (QoE model while evaluating the service quality. A lot of work that tries to evaluate the quality of audio, video, and multimedia services over the Internet has been done. At the same time, research is also going on trying to map the two different domains of quality metrics, i.e., the QoS and QoE domain. Apart from the work done by individual researchers, the International Telecommunications Union (ITU has been quite active in this area of quality assessment. This is obvious from the large number of ITU standards that are available for different application types. The sheer variety of techniques being employed by ITU as well as other researchers sometimes tends to be too complex and diversified. Although there are survey papers that try to present the current state of the art methodologies for video quality evaluation, none has focused on the ITU perspective. In this work, we try to fill up this void by presenting up-to-date information on the different measurement methods that are currently being employed by ITU for a video streaming scenario. We highlight the outline of each method with sufficient detail and try to analyze the challenges being faced along with the direction of future research.

  3. Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization

    International Nuclear Information System (INIS)

    Holmes, D.R. Jr.; Bove, A.A.; Wondrow, M.A.; Gray, J.E.

    1986-01-01

    A newly developed video x-ray progressive scanning system improves image quality, decreases radiation exposure, and can be added to any pulsed fluoroscopic x-ray system using a video display without major system modifications. With use of progressive video scanning, the radiation entrance exposure rate measured with a vascular phantom was decreased by 32 to 53% in comparison with a conventional fluoroscopic x-ray system. In addition to this substantial decrease in radiation exposure, the quality of the image was improved because of less motion blur and artifact. Progressive video scanning has the potential for widespread application to all pulsed fluoroscopic x-ray systems. Use of this technique should make cardiac catheterization procedures and all other fluoroscopic procedures safer for the patient and the involved medical and paramedical staff

  4. Multi-modal highlight generation for sports videos using an information-theoretic excitability measure

    Science.gov (United States)

    Hasan, Taufiq; Bořil, Hynek; Sangwan, Abhijeet; L Hansen, John H.

    2013-12-01

    The ability to detect and organize `hot spots' representing areas of excitement within video streams is a challenging research problem when techniques rely exclusively on video content. A generic method for sports video highlight selection is presented in this study which leverages both video/image structure as well as audio/speech properties. Processing begins where the video is partitioned into small segments and several multi-modal features are extracted from each segment. Excitability is computed based on the likelihood of the segmental features residing in certain regions of their joint probability density function space which are considered both exciting and rare. The proposed measure is used to rank order the partitioned segments to compress the overall video sequence and produce a contiguous set of highlights. Experiments are performed on baseball videos based on signal processing advancements for excitement assessment in the commentators' speech, audio energy, slow motion replay, scene cut density, and motion activity as features. Detailed analysis on correlation between user excitability and various speech production parameters is conducted and an effective scheme is designed to estimate the excitement level of commentator's speech from the sports videos. Subjective evaluation of excitability and ranking of video segments demonstrate a higher correlation with the proposed measure compared to well-established techniques indicating the effectiveness of the overall approach.

  5. Management of speech and video telephony quality in heterogeneous wireless networks

    CERN Document Server

    Lewcio, Błażej

    2014-01-01

    This book shows how networking research and quality engineering can be combined to successfully manage the transmission quality when speech and video telephony is delivered in heterogeneous wireless networks. Nomadic use of services requires intelligent management of ongoing transmission, and to make the best of available resources many fundamental trade-offs must be considered. Network coverage versus throughput and reliability of a connection is one key aspect, efficiency versus robustness of signal compression is another. However, to successfully manage services, user-perceived Quality of Experience (QoE) in heterogeneous networks must be known, and the perception of quality changes must be understood.  These issues are addressed in this book, in particular focusing on the perception of quality changes due to switching between diverse networks, speech and video codecs, and encoding bit rates during active calls.

  6. Blind identification of full-field vibration modes from video measurements with phase-based video motion magnification

    Science.gov (United States)

    Yang, Yongchao; Dorn, Charles; Mancini, Tyler; Talken, Zachary; Kenyon, Garrett; Farrar, Charles; Mascareñas, David

    2017-02-01

    Experimental or operational modal analysis traditionally requires physically-attached wired or wireless sensors for vibration measurement of structures. This instrumentation can result in mass-loading on lightweight structures, and is costly and time-consuming to install and maintain on large civil structures, especially for long-term applications (e.g., structural health monitoring) that require significant maintenance for cabling (wired sensors) or periodic replacement of the energy supply (wireless sensors). Moreover, these sensors are typically placed at a limited number of discrete locations, providing low spatial sensing resolution that is hardly sufficient for modal-based damage localization, or model correlation and updating for larger-scale structures. Non-contact measurement methods such as scanning laser vibrometers provide high-resolution sensing capacity without the mass-loading effect; however, they make sequential measurements that require considerable acquisition time. As an alternative non-contact method, digital video cameras are relatively low-cost, agile, and provide high spatial resolution, simultaneous, measurements. Combined with vision based algorithms (e.g., image correlation, optical flow), video camera based measurements have been successfully used for vibration measurements and subsequent modal analysis, based on techniques such as the digital image correlation (DIC) and the point-tracking. However, they typically require speckle pattern or high-contrast markers to be placed on the surface of structures, which poses challenges when the measurement area is large or inaccessible. This work explores advanced computer vision and video processing algorithms to develop a novel video measurement and vision-based operational (output-only) modal analysis method that alleviate the need of structural surface preparation associated with existing vision-based methods and can be implemented in a relatively efficient and autonomous manner with little

  7. A Dataset for Education-Related Majors' Performance Measures with Pre/Post-Video Game Practice

    Science.gov (United States)

    Novak, Elena; Tassell, Janet Lynne

    2015-01-01

    This dataset includes a series of 30 education-related majors' performance measures before and after they completed a 10-hour video game practice in a computer lab. The goal of the experimental study was to examine the effects of action video gaming on students' mathematics performance and mathematics anxiety as mediated by the effect of attention…

  8. Reproducibility and validity of video screen measurements of gait in children with spastic cerebral palsy.

    NARCIS (Netherlands)

    Grunt, S.; van Kampen, P.M.; van der Krogt, M.M.; Brehm, M.A.; Doorenbosch, C.A.M.; Becher, J.G.

    2010-01-01

    Purpose: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. Methods: 17 children with spastic cerebral palsy walked on a 10. m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators

  9. Reproducibility and validity of video screen measurements of gait in children with spastic cerebral palsy

    NARCIS (Netherlands)

    Grunt, Sebastian; van Kampen, Petra J.; van der Krogt, Marjolein M.; Brehm, Merel-Anne; Doorenbosch, Caroline A. M.; Becher, Jules G.

    2010-01-01

    PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators

  10. Quality Variation Control for Three-Dimensional Wavelet-Based Video Coders

    Directory of Open Access Journals (Sweden)

    Vidhya Seran

    2007-02-01

    Full Text Available The fluctuation of quality in time is a problem that exists in motion-compensated-temporal-filtering (MCTF- based video coding. The goal of this paper is to design a solution for overcoming the distortion fluctuation challenges faced by wavelet-based video coders. We propose a new technique for determining the number of bits to be allocated to each temporal subband in order to minimize the fluctuation in the quality of the reconstructed video. Also, the wavelet filter properties are explored to design suitable scaling coefficients with the objective of smoothening the temporal PSNR. The biorthogonal 5/3 wavelet filter is considered in this paper and experimental results are presented for 2D+t and t+2D MCTF wavelet coders.

  11. Quality Variation Control for Three-Dimensional Wavelet-Based Video Coders

    Directory of Open Access Journals (Sweden)

    Seran Vidhya

    2007-01-01

    Full Text Available The fluctuation of quality in time is a problem that exists in motion-compensated-temporal-filtering (MCTF- based video coding. The goal of this paper is to design a solution for overcoming the distortion fluctuation challenges faced by wavelet-based video coders. We propose a new technique for determining the number of bits to be allocated to each temporal subband in order to minimize the fluctuation in the quality of the reconstructed video. Also, the wavelet filter properties are explored to design suitable scaling coefficients with the objective of smoothening the temporal PSNR. The biorthogonal 5/3 wavelet filter is considered in this paper and experimental results are presented for 2D+t and t+2D MCTF wavelet coders.

  12. Modeling the Color Image and Video Quality on Liquid Crystal Displays with Backlight Dimming

    DEFF Research Database (Denmark)

    Korhonen, Jari; Mantel, Claire; Burini, Nino

    2013-01-01

    Objective image and video quality metrics focus mostly on the digital representation of the signal. However, the display characteristics are also essential for the overall Quality of Experience (QoE). In this paper, we use a model of a backlight dimming system for Liquid Crystal Display (LCD......) and show how the modeled image can be used as an input to quality assessment algorithms. For quality assessment, we propose an image quality metric, based on Peak Signal-to-Noise Ratio (PSNR) computation in the CIE L*a*b* color space. The metric takes luminance reduction, color distortion and loss...

  13. Video Game Learning Dynamics: Actionable Measures of Multidimensional Learning Trajectories

    Science.gov (United States)

    Reese, Debbie Denise; Tabachnick, Barbara G.; Kosko, Robert E.

    2015-01-01

    Valid, accessible, reusable methods for instructional video game design and embedded assessment can provide actionable information enhancing individual and collective achievement. Cyberlearning through game-based, metaphor-enhanced learning objects (CyGaMEs) design and embedded assessment quantify player behavior to study knowledge discovery and…

  14. ATM Quality of Service Tests for Digitized Video Using ATM Over Satellite: Laboratory Tests

    Science.gov (United States)

    Ivancic, William D.; Brooks, David E.; Frantz, Brian D.

    1997-01-01

    A digitized video application was used to help determine minimum quality of service parameters for asynchronous transfer mode (ATM) over satellite. For these tests, binomially distributed and other errors were digitally inserted in an intermediate frequency link via a satellite modem and a commercial gaussian noise generator. In this paper, the relation- ship between the ATM cell error and cell loss parameter specifications is discussed with regard to this application. In addition, the video-encoding algorithms, test configurations, and results are presented in detail.

  15. Educational Quality of YouTube Videos in Thumb Exercises for Carpometacarpal Osteoarthritis: A Search on Current Practice.

    Science.gov (United States)

    Villafañe, Jorge Hugo; Cantero-Tellez, Raquel; Valdes, Kristin; Usuelli, Federico Giuseppe; Berjano, Pedro

    2017-09-01

    Conservative treatments are commonly performed therapeutic interventions for the management of carpometacarpal (CMC) joint osteoarthritis (OA). Physical and occupational therapies are starting to use video-based online content as both a patient teaching tool and a source for treatment techniques. YouTube is a popular video-sharing website that can be accessed easily. The purpose of this study was to analyze the quality of content and potential sources of bias in videos available on YouTube pertaining to thumb exercises for CMC OA. The YouTube video database was systematically searched using the search term thumb osteoarthritis and exercises from its inception to March 10, 2017. Authors independently selected videos, conducted quality assessment, and extracted results. A total of 832 videos were found using the keywords. Of these, 10 videos clearly demonstrated therapeutic exercise for the management of CMC OA. In addition, the top-ranked video found by performing a search of "views" was a video with more than 121 863 views uploaded in 2015 that lasted 12.33 minutes and scored only 2 points on the Global Score for Educational Value rating scale. Most of the videos viewed that described conservative interventions for CMC OA management have a low level of evidence to support their use. Although patients and novice hand therapists are using YouTube and other online resources, videos that are produced by expert hand therapists are scarce.

  16. Measurement of laser spot quality

    Science.gov (United States)

    Milster, T. D.; Treptau, J. P.

    1991-01-01

    Several ways of measuring spot quality are compared. We examine in detail various figures of merit such as full width at half maximum (FWHM), full width at 1/(e exp 2) maximum, Strehl ratio, and encircled energy. Our application is optical data storage, but results can be applied to other areas like space communications and high energy lasers. We found that the optimum figure of merit in many cases is Strehl ratio.

  17. Architectures for radio over fiber transmission of high-quality video and data signals

    DEFF Research Database (Denmark)

    Lebedev, Alexander

    with a constraint on complexity. For wireless personal area networks distribution, we explore the notion of joint optimization of physical layer parameters of a fiber-wireless link (optical power levels, wireless transmission distance) and the codec parameters (quantization, error-resilience tools) based...... on the peak signal-to-noise ratio as an objective video quality metric for compressed video transmission. Furthermore, we experimentally demonstrate uncompressed 1080i highdefinition video distribution in V-band (50–75 GHz) and W-band (75–110 GHz) fiber-wireless links achieving 3 m of wireless transmission...... efficient wired/wireless backhaul of picocell networks. Gigabit signal transmission is realized in combined fiber-wireless-fiber link enabling simultaneous backhaul of dense metropolitan and suburban areas. In this Thesis, we propose a technique to combat periodic chromatic dispersion-induced radio...

  18. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1977-01-01

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  19. Subjective quality of video sequences rendered on LCD with local backlight dimming at different lighting conditions

    Science.gov (United States)

    Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.; Bech, Søren; Andersen, Jakob Dahl; Forchhammer, Søren

    2015-01-01

    This paper focuses on the influence of ambient light on the perceived quality of videos displayed on Liquid Crystal Display (LCD) with local backlight dimming. A subjective test assessing the quality of videos with two backlight dimming methods and three lighting conditions, i.e. no light, low light level (5 lux) and higher light level (60 lux) was organized to collect subjective data. Results show that participants prefer the method exploiting local dimming possibilities to the conventional full backlight but that this preference varies depending on the ambient light level. The clear preference for one method at the low light conditions decreases at the high ambient light, confirming that the ambient light significantly attenuates the perception of the leakage defect (light leaking through dark pixels). Results are also highly dependent on the content of the sequence, which can modulate the effect of the ambient light from having an important influence on the quality grades to no influence at all.

  20. A novel no-reference objective stereoscopic video quality assessment method based on visual saliency analysis

    Science.gov (United States)

    Yang, Xinyan; Zhao, Wei; Ye, Long; Zhang, Qin

    2017-07-01

    This paper proposes a no-reference objective stereoscopic video quality assessment method with the motivation that making the effect of objective experiments close to that of subjective way. We believe that the image regions with different visual salient degree should not have the same weights when designing an assessment metric. Therefore, we firstly use GBVS algorithm to each frame pairs and separate both the left and right viewing images into the regions with strong, general and week saliency. Besides, local feature information like blockiness, zero-crossing and depth are extracted and combined with a mathematical model to calculate a quality assessment score. Regions with different salient degree are assigned with different weights in the mathematical model. Experiment results demonstrate the superiority of our method compared with the existed state-of-the-art no-reference objective Stereoscopic video quality assessment methods.

  1. Everything is ok on YouTube! Quality assessment of YouTube videos on the topic of phacoemulsification in eyes with small pupil.

    Science.gov (United States)

    Aykut, Aslan; Kukner, Amber Senel; Karasu, Bugra; Palancıglu, Yeliz; Atmaca, Fatih; Aydogan, Tumay

    2018-01-22

    Usage of YouTube as an educational tool is gaining attention in academic research. To date, there has been no study on the content and quality of eye surgery videos on YouTube. The aim of this study was to analyze YouTube videos on phacoemulsification in eyes with small pupil. We searched for the phrases "small pupil cataract surgery," "small pupil phacoemulsification," "small pupil cataract surgery complications," and "small pupil phacoemulsification complications" in January 2015. Each resulting video was evaluated by all authors, and Krippendorff's alpha was calculated to measure agreement. Videos were classified according to pupil size (small/very small) in the beginning of the surgery, and whether pupillary diameter was large enough to continue surgery safely after pupillary dilation by the surgeon in the video (safe/not safe). Methods of dilatation were also analyzed. Any stated ocular comorbidity or surgical complications were noted. A total of 96 videos were reviewed. No mechanical intervention for pupillary dilatation was performed in 46 videos. Fifty-eight operated eyes had no stated ocular comorbidity. Ninety-five operations ended successfully without major complication. There was fair agreement between the evaluators regarding pupil sizes (Kα = 0.670) but poor agreement regarding safety (Kα = 0.337). YouTube videos on small pupil phacoemulsification have low complication rates when compared to the literature, although no reliable mechanical dilatation methods are used in almost half of these videos. Until YouTube's place in e-learning becomes clearer, we suggest that viewers be cautious regarding small pupil phacoemulsification videos on YouTube.

  2. Quality assurance in biomarker measurement.

    Science.gov (United States)

    Aitio, A; Apostoli, P

    1995-05-01

    Quality assurance (QA) concerns the validity of all the analytical processes (from collection of the samples to interpretation of the results). It is not an abstract concept but must be adapted to the different situations such as the different exposure levels, the different analytical methods, and the context of use (risk assessment procedures, research, routine determinations). The main requirements in QA programmes regard the control of all the known sources of preanalytical and analytical variations, while the instruments with which adequate QA can be implemented are the certified materials and the quality control programmes (quality manual, internal and external quality controls). Another important concept in QA is that measurements must be placed a different metrological levels: at the highest there are the methods (definitive, reference) to be used for assessing accuracy of routine methods. QA programmes should enable a grading of biomarkers (from experimental only to full evaluated) and of the laboratories in order to identify the significance of the test and to assess the level at which a laboratory could operate.

  3. Constructing a no-reference H.264/AVC bitstream-based video quality metric using genetic programming-based symbolic regression

    OpenAIRE

    Staelens, Nicolas; Deschrijver, Dirk; Vladislavleva, E; Vermeulen, Brecht; Dhaene, Tom; Demeester, Piet

    2013-01-01

    In order to ensure optimal quality of experience toward end users during video streaming, automatic video quality assessment becomes an important field-of-interest to video service providers. Objective video quality metrics try to estimate perceived quality with high accuracy and in an automated manner. In traditional approaches, these metrics model the complex properties of the human visual system. More recently, however, it has been shown that machine learning approaches can also yield comp...

  4. Traffic and Quality Characterization of the H.264/AVC Scalable Video Coding Extension

    Directory of Open Access Journals (Sweden)

    Geert Van der Auwera

    2008-01-01

    Full Text Available The recent scalable video coding (SVC extension to the H.264/AVC video coding standard has unprecedented compression efficiency while supporting a wide range of scalability modes, including temporal, spatial, and quality (SNR scalability, as well as combined spatiotemporal SNR scalability. The traffic characteristics, especially the bit rate variabilities, of the individual layer streams critically affect their network transport. We study the SVC traffic statistics, including the bit rate distortion and bit rate variability distortion, with long CIF resolution video sequences and compare them with the corresponding MPEG-4 Part 2 traffic statistics. We consider (i temporal scalability with three temporal layers, (ii spatial scalability with a QCIF base layer and a CIF enhancement layer, as well as (iii quality scalability modes FGS and MGS. We find that the significant improvement in RD efficiency of SVC is accompanied by substantially higher traffic variabilities as compared to the equivalent MPEG-4 Part 2 streams. We find that separately analyzing the traffic of temporal-scalability only encodings gives reasonable estimates of the traffic statistics of the temporal layers embedded in combined spatiotemporal encodings and in the base layer of combined FGS-temporal encodings. Overall, we find that SVC achieves significantly higher compression ratios than MPEG-4 Part 2, but produces unprecedented levels of traffic variability, thus presenting new challenges for the network transport of scalable video.

  5. Quality Assurance In Radioactivity Measurements

    International Nuclear Information System (INIS)

    Riekstina, D.; Veveris, O.; Smilskalne, G.

    2007-01-01

    The credibility of obtained results is ensured by the quality assurance and control. The main requisitions involved in the quality assurance of the laboratory according to the requirements of LVS EN ISO/IEC 17025:2005 are: 1) the use of calibrated equipment only; 2) the regular and long-time use of reference materials in the control of equipment; 3) the estimation of uncertainty sources and determination of uncertainties within the given interval of credibility; 4) the validation and verification. The very important requirement is regular participation in the interlaboratory intercomparison exercises that makes it possible to estimate and find possible error sources and carry out the corrective actions. The measurements of the radioactivity of Cs-137, Co-60, H-3, the natural radioactive nuclides as well as other radionuclides in different environmental (soil, precipitation, different types of water, needles, et al.) samples, and in various radioactive polluted objects are carried out in the Laboratory of Radiation physics. The quality assurance system was implemented in our laboratory in 2000. Since 1999 laboratory is regular participant in the interlaboratory intercomparison exercises, organized by the RISO National Laboratory (Denmark) and IAEA (Vienna). The paper shows the laboratory's system of quality assurance and its implementation. We have the internal quality audit program that takes into account the requirements of LVS EN ISO/IEC 17025: 2005, but the main attention is paid to the intercomparison of the results of analyses of laboratories, their evaluation and interpretation. Only credible and justified results can be the basis for further use in any field, thus making it possible to make legitimate decisions. (Authors)

  6. The Measurement and Modeling of a P2P Streaming Video Service

    Science.gov (United States)

    Gao, Peng; Liu, Tao; Chen, Yanming; Wu, Xingyao; El-Khatib, Yehia; Edwards, Christopher

    Most of the work on grid technology in video area has been generally restricted to aspects of resource scheduling and replica management. The traffic of such service has a lot of characteristics in common with that of the traditional video service. However the architecture and user behavior in Grid networks are quite different from those of traditional Internet. Considering the potential of grid networks and video sharing services, measuring and analyzing P2P IPTV traffic are important and fundamental works in the field grid networks.

  7. A model for measurement of noise in CCD digital-video cameras

    International Nuclear Information System (INIS)

    Irie, K; Woodhead, I M; McKinnon, A E; Unsworth, K

    2008-01-01

    This study presents a comprehensive measurement of CCD digital-video camera noise. Knowledge of noise detail within images or video streams allows for the development of more sophisticated algorithms for separating true image content from the noise generated in an image sensor. The robustness and performance of an image-processing algorithm is fundamentally limited by sensor noise. The individual noise sources present in CCD sensors are well understood, but there has been little literature on the development of a complete noise model for CCD digital-video cameras, incorporating the effects of quantization and demosaicing

  8. Quality-Based Backlight Optimization for Video Playback on Handheld Devices

    Directory of Open Access Journals (Sweden)

    Liang Cheng

    2007-01-01

    Full Text Available For a typical handheld device, the backlight accounts for a significant percentage of the total energy consumption (e.g., around 30% for a Compaq iPAQ 3650. Substantial energy savings can be achieved by dynamically adapting backlight intensity levels on such low-power portable devices. In this paper, we analyze the characteristics of video streaming services and propose a cross-layer optimization scheme called quality adapted backlight scaling (QABS to achieve backlight energy savings for video playback applications on handheld devices. Specifically, we present a fast algorithm to optimize backlight dimming while keeping the degradation in image quality to a minimum so that the overall service quality is close to a specified threshold. Additionally, we propose two effective techniques to prevent frequent backlight switching, which negatively affects user perception of video. Our initial experimental results indicate that the energy used for backlight is significantly reduced, while the desired quality is satisfied. The proposed algorithms can be realized in real time.

  9. Task-oriented quality assessment and adaptation in real-time mission critical video streaming applications

    Science.gov (United States)

    Nightingale, James; Wang, Qi; Grecos, Christos

    2015-02-01

    In recent years video traffic has become the dominant application on the Internet with global year-on-year increases in video-oriented consumer services. Driven by improved bandwidth in both mobile and fixed networks, steadily reducing hardware costs and the development of new technologies, many existing and new classes of commercial and industrial video applications are now being upgraded or emerging. Some of the use cases for these applications include areas such as public and private security monitoring for loss prevention or intruder detection, industrial process monitoring and critical infrastructure monitoring. The use of video is becoming commonplace in defence, security, commercial, industrial, educational and health contexts. Towards optimal performances, the design or optimisation in each of these applications should be context aware and task oriented with the characteristics of the video stream (frame rate, spatial resolution, bandwidth etc.) chosen to match the use case requirements. For example, in the security domain, a task-oriented consideration may be that higher resolution video would be required to identify an intruder than to simply detect his presence. Whilst in the same case, contextual factors such as the requirement to transmit over a resource-limited wireless link, may impose constraints on the selection of optimum task-oriented parameters. This paper presents a novel, conceptually simple and easily implemented method of assessing video quality relative to its suitability for a particular task and dynamically adapting videos streams during transmission to ensure that the task can be successfully completed. Firstly we defined two principle classes of tasks: recognition tasks and event detection tasks. These task classes are further subdivided into a set of task-related profiles, each of which is associated with a set of taskoriented attributes (minimum spatial resolution, minimum frame rate etc.). For example, in the detection class

  10. Measuring Physical Inactivity: Do Current Measures Provide an Accurate View of “Sedentary” Video Game Time?

    Directory of Open Access Journals (Sweden)

    Simon Fullerton

    2014-01-01

    Full Text Available Background. Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Methods. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n=2026 were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Results. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children’s video game time. Conclusions. A substantial proportion of time that would usually be classified as “sedentary” may actually be spent participating in light to moderate physical activity.

  11. Achieving Improvement Through Nursing Home Quality Measurement

    OpenAIRE

    Harris, Yael; Clauser, Steven B.

    2002-01-01

    CMS has initiated the Nursing Home Quality Initiative (NHQI) to improve the quality of nursing home care. Central to the NHQI is the public reporting of nursing home quality measures that serve as the basis for the Initiative's communication and quality improvement program. This article provides an overview of the NHQI, focusing on the role of nursing home quality measures in achieving improvements in nursing home care. We also describe the evolution of quality measurement in nursing homes, a...

  12. Subjective quality of video sequences rendered on LCD with local backlight dimming at different lighting conditions

    DEFF Research Database (Denmark)

    Mantel, Claire; Korhonen, Jari; Pedersen, Jesper Mørkhøj

    2015-01-01

    This paper focuses on the influence of ambient light on the perceived quality of videos displayed on Liquid Crystal Display (LCD) with local backlight dimming. A subjective test assessing the quality of videos with two backlight dimming methods and three lighting conditions, i.e. no light, low...... light level (5 lux) and higher light level (60 lux) was organized to collect subjective data. Results show that participants prefer the method exploiting local dimming possibilities to the conventional full backlight but that this preference varies depending on the ambient light level. The clear...... preference for one method at the low light conditions decreases at the high ambient light, confirming that the ambient light significantly attenuates the perception of the leakage defect (light leaking through dark pixels). Results are also highly dependent on the content of the sequence, which can modulate...

  13. Development and Validation of a Video Measure for Assessing Women’s Risk Perception for Alcohol-Related Sexual Assault

    Science.gov (United States)

    Parks, Kathleen A.; Levonyan-Radloff, Kristine; Dearing, Ronda L.; Hequembourg, Amy; Testa, Maria

    2016-01-01

    Objective Using an iterative process, a series of three video scenarios were developed for use as a standardized measure for assessing women’s perception of risks for alcohol-related sexual assault (SA). The videos included ambiguous and clear behavioral and environmental risk cues. Method Focus group discussions with young, female heavy drinkers (N = 42) were used to develop three videos at different risk levels (low, moderate, and high) in Study 1. Realism, reliability, and validity of the videos were assessed using multiple methods in Studies 2 and 3. One hundred-four women were used to compare differences in risk perception across the video risk level in Study 2. In Study 3 (N = 60), we assessed women’s perceptions of the low and high risk videos under conditions of no alcohol and alcohol. Results The realism and reliability of the videos were good. Women who viewed the low risk video compared to women who viewed the moderate and high risk videos perceived less risk for SA. We found an interaction between alcohol and risk perception such that, women in the alcohol condition were less likely to perceive risk when watching the high risk video. Conclusions As the video risk level increased, women’s perception of risk increased. These findings provide convergent evidence for the validity of the video measure. Given the limited number of standardized scenarios for assessing risk perception for sexual assault, our findings suggest that these videos may provide a needed standardized measure. PMID:27747131

  14. Examining human behavior in video games: The development of a computational model to measure aggression.

    Science.gov (United States)

    Lamb, Richard; Annetta, Leonard; Hoston, Douglas; Shapiro, Marina; Matthews, Benjamin

    2018-06-01

    Video games with violent content have raised considerable concern in popular media and within academia. Recently, there has been considerable attention regarding the claim of the relationship between aggression and video game play. The authors of this study propose the use of a new class of tools developed via computational models to allow examination of the question of whether there is a relationship between violent video games and aggression. The purpose of this study is to computationally model and compare the General Aggression Model with the Diathesis Mode of Aggression related to the play of violent content in video games. A secondary purpose is to provide a method of measuring and examining individual aggression arising from video game play. Total participants examined for this study are N = 1065. This study occurs in three phases. Phase 1 is the development and quantification of the profile combination of traits via latent class profile analysis. Phase 2 is the training of the artificial neural network. Phase 3 is the comparison of each model as a computational model with and without the presence of video game violence. Results suggest that a combination of environmental factors and genetic predispositions trigger aggression related to video games.

  15. Quality optimization of H.264/AVC video transmission over noisy environments using a sparse regression framework

    Science.gov (United States)

    Pandremmenou, K.; Tziortziotis, N.; Paluri, S.; Zhang, W.; Blekas, K.; Kondi, L. P.; Kumar, S.

    2015-03-01

    We propose the use of the Least Absolute Shrinkage and Selection Operator (LASSO) regression method in order to predict the Cumulative Mean Squared Error (CMSE), incurred by the loss of individual slices in video transmission. We extract a number of quality-relevant features from the H.264/AVC video sequences, which are given as input to the LASSO. This method has the benefit of not only keeping a subset of the features that have the strongest effects towards video quality, but also produces accurate CMSE predictions. Particularly, we study the LASSO regression through two different architectures; the Global LASSO (G.LASSO) and Local LASSO (L.LASSO). In G.LASSO, a single regression model is trained for all slice types together, while in L.LASSO, motivated by the fact that the values for some features are closely dependent on the considered slice type, each slice type has its own regression model, in an e ort to improve LASSO's prediction capability. Based on the predicted CMSE values, we group the video slices into four priority classes. Additionally, we consider a video transmission scenario over a noisy channel, where Unequal Error Protection (UEP) is applied to all prioritized slices. The provided results demonstrate the efficiency of LASSO in estimating CMSE with high accuracy, using only a few features. les that typically contain high-entropy data, producing a footprint that is far less conspicuous than existing methods. The system uses a local web server to provide a le system, user interface and applications through an web architecture.

  16. The Relationship between Video Game Use and a Performance-Based Measure of Persistence

    Science.gov (United States)

    Ventura, Matthew; Shute, Valerie; Zhao, Weinan

    2013-01-01

    An online performance-based measure of persistence was developed using anagrams and riddles. Persistence was measured by recording the time spent on unsolved anagrams and riddles. Time spent on unsolved problems was correlated to a self-report measure of persistence. Additionally, frequent video game players spent longer times on unsolved problems…

  17. Measuring effectiveness of food quality management

    NARCIS (Netherlands)

    Spiegel, van der M.

    2004-01-01

    Keywords: effectiveness, food quality management, instrument, quality performance, contextual factors, agri-food production, conceptual model, performance measurement indicators, identification, validation, assessment, quality assurance systems, QA systems, HACCP, Hygiene code, ISO, BRC, GMP, bakery

  18. Video training and certification program improves reliability of postischemic neurologic deficit measurement in the rat.

    Science.gov (United States)

    Taninishi, Hideki; Pearlstein, Molly; Sheng, Huaxin; Izutsu, Miwa; Chaparro, Rafael E; Goldstein, Larry B; Warner, David S

    2016-12-01

    Scoring systems are used to measure behavioral deficits in stroke research. Video-assisted training is used to standardize stroke-related neurologic deficit scoring in humans. We hypothesized that a video-assisted training and certification program can improve inter-rater reliability in assessing neurologic function after middle cerebral artery occlusion in rats. Three expert raters scored neurologic deficits in post-middle cerebral artery occlusion rats using three published systems having different complexity levels (3, 18, or 48 points). The system having the highest point estimate for the correlation between neurologic score and infarct size was selected to create a video-assisted training and certification program. Eight trainee raters completed the video-assisted training and certification program. Inter-rater agreement ( Κ: score) and agreement with expert consensus scores were measured before and after video-assisted training and certification program completion. The 48-point system correlated best with infarct size. Video-assisted training and certification improved agreement with expert consensus scores (pretraining = 65 ± 10, posttraining = 87 ± 14, 112 possible scores, P  0.4 (pretraining = 4, posttraining = 9), and number of categories with an improvement in the Κ: score from pretraining to posttraining (n = 6). Video-assisted training and certification improved trainee inter-rater reliability and agreement with expert consensus behavioral scores in rats after middle cerebral artery occlusion. Video-assisted training and certification may be useful in multilaboratory preclinical studies. © The Author(s) 2015.

  19. The Quality of Open-Access Video-Based Orthopaedic Instructional Content for the Shoulder Physical Exam is Inconsistent.

    Science.gov (United States)

    Urch, Ekaterina; Taylor, Samuel A; Cody, Elizabeth; Fabricant, Peter D; Burket, Jayme C; O'Brien, Stephen J; Dines, David M; Dines, Joshua S

    2016-10-01

    The internet has an increasing role in both patient and physician education. While several recent studies critically appraised the quality and accuracy of web-based written information available to patients, no studies have evaluated such parameters for open-access video content designed for provider use. The primary goal of the study was to determine the accuracy of internet-based instructional videos featuring the shoulder physical examination. An assessment of quality and accuracy of said video content was performed using the basic shoulder examination as a surrogate for the "best-case scenario" due to its widely accepted components that are stable over time. Three search terms ("shoulder," "examination," and "shoulder exam") were entered into the four online video resources most commonly accessed by orthopaedic surgery residents (VuMedi, G9MD, Orthobullets, and YouTube). Videos were captured and independently reviewed by three orthopaedic surgeons. Quality and accuracy were assessed in accordance with previously published standards. Of the 39 video tutorials reviewed, 61% were rated as fair or poor. Specific maneuvers such as the Hawkins test, O'Brien sign, and Neer impingement test were accurately demonstrated in 50, 36, and 27% of videos, respectively. Inter-rater reliability was excellent (mean kappa 0.80, range 0.79-0.81). Our results suggest that information presented in open-access video tutorials featuring the physical examination of the shoulder is inconsistent. Trainee exposure to such potentially inaccurate information may have a significant impact on trainee education.

  20. Extracting a Good Quality Frontal Face Image from a Low-Resolution Video Sequence

    DEFF Research Database (Denmark)

    Nasrollahi, Kamal; Moeslund, Thomas B.

    2011-01-01

    Feeding low-resolution and low-quality images, from inexpensive surveillance cameras, to systems like, e.g., face recognition, produces erroneous and unstable results. Therefore, there is a need for a mechanism to bridge the gap between on one hand low-resolution and low-quality images......, we use a learning-based super-resolution algorithm applied to the result of the reconstruction-based part to improve the quality by another factor of two. This results in an improvement factor of four for the entire system. The proposed system has been tested on 122 low-resolution sequences from two...... different databases. The experimental results show that the proposed system can indeed produce a high-resolution and good quality frontal face image from low-resolution video sequences....

  1. Hospital Quality Initiative - Outcome Measures

    Data.gov (United States)

    U.S. Department of Health & Human Services — In the interest of promoting high-quality, patient-centered care and accountability, the Centers for Medicare and Medicaid Services (CMS) and Hospital Quality...

  2. Creating a Novel Video Vignette Stroke Preparedness Outcome Measure Using a Community-Based Participatory Approach.

    Science.gov (United States)

    Skolarus, Lesli E; Murphy, Jillian B; Dome, Mackenzie; Zimmerman, Marc A; Bailey, Sarah; Fowlkes, Sophronia; Morgenstern, Lewis B

    2015-07-01

    Evaluating the efficacy of behavioral interventions for rare outcomes is a challenge. One such topic is stroke preparedness, defined as inteventions to increase stroke symptom recognition and behavioral intent to call 911. Current stroke preparedness intermediate outcome measures are centered on written vignettes or open-ended questions and have been shown to poorly reflect actual behavior. Given that stroke identification and action requires aural and visual processing, video vignettes may improve on current measures. This article discusses an approach for creating a novel stroke preparedness video vignette intermediate outcome measure within a community-based participatory research partnership. A total of 20 video vignettes were filmed of which 13 were unambiguous (stroke or not stroke) as determined by stroke experts and had test discrimination among community participants. Acceptable reliability, high satisfaction, and cultural relevance were found among the 14 community respondents. A community-based participatory approach was effective in creating a video vignette intermediate outcome. Future projects should consider obtaining expert and community feedback prior to filming all the video vignettes to improve the proportion of vignettes that are usable. While content validity and preliminary reliability were established, future studies are needed to confirm the reliability and establish construct validity. © 2014 Society for Public Health Education.

  3. A blinded assessment of video quality in wearable technology for telementoring in open surgery: the Google Glass experience.

    Science.gov (United States)

    Hashimoto, Daniel A; Phitayakorn, Roy; Fernandez-del Castillo, Carlos; Meireles, Ozanan

    2016-01-01

    The goal of telementoring is to recreate face-to-face encounters with a digital presence. Open-surgery telementoring is limited by lack of surgeon's point-of-view cameras. Google Glass is a wearable computer that looks like a pair of glasses but is equipped with wireless connectivity, a camera, and viewing screen for video conferencing. This study aimed to assess the safety of using Google Glass by assessing the video quality of a telementoring session. Thirty-four (n = 34) surgeons at a single institution were surveyed and blindly compared via video captured with Google Glass versus an Apple iPhone 5 during the open cholecystectomy portion of a Whipple. Surgeons were asked to evaluate the quality of the video and its adequacy for safe use in telementoring. Thirty-four of 107 invited surgical attendings (32%) responded to the anonymous survey. A total of 50% rated the Google Glass video as fair with the other 50% rating it as bad to poor. A total of 52.9% of respondents rated the Apple iPhone video as good. A significantly greater proportion of respondents felt Google Glass video quality was inadequate for telementoring versus the Apple iPhone's (82.4 vs 26.5%, p safe telementoring. As the device is still in initial phases of development, future iterations or competitor devices may provide a better telementoring application for wearable devices.

  4. Online and offline video game use in adolescents: measurement invariance and problem severity.

    Science.gov (United States)

    Smohai, Máté; Urbán, Róbert; Griffiths, Mark D; Király, Orsolya; Mirnics, Zsuzsanna; Vargha, András; Demetrovics, Zsolt

    2017-01-01

    Despite the increasing popularity of video game playing, little is known about the similarities and differences between online and offline video game players. The aims of this study were (i) to test the applicability and the measurement invariance of the previously developed Problematic Online Gaming Questionnaire (POGQ) in both online and offline gamers and to (ii) examine the differences in these groups. Video game use habits and POGQ were assessed in a sample of 1,964 (71% male) adolescent videogame players. Those gamers who played at least sometimes in an online context were considered "online gamers," while those who played videogames exclusively offline were considered "offline gamers." Confirmatory factor analysis supported the measurement invariance across online and offline videogame players. According to the multiple indicators multiple causes (MIMIC) model, online gamers were more likely to score higher on overuse, interpersonal conflict, and social isolation subscales of the POGQ. The results of the present study suggest that online and offline gaming can be assessed using the same psychometric instrument. These findings open the possibility for future research studies concerning problematic video gaming to include participants who exclusively play online or offline games, or both. However, the study also identified important structural features about how online and offline gaming might contribute differently to problematic use. These results provide important information that could be utilized in parental education and the prevention program about the possible detrimental consequences of online vs. offline video gaming.

  5. An instrument for X-ray set quality assurance measurements

    International Nuclear Information System (INIS)

    Willetts, R.J.; West, M.B.; Brydon, J.

    1989-01-01

    This paper describes a prototype electronic instrument for performing quality assurance (QA) measurements on diagnostic radiological equipment with a view to long-term performance assessment on a Regional basis. The instrument is based on a Tandy 200 laptop computer and has been developed primarily to include the assessment of image intensifier/TV systems in a general QA package. It is capable of accepting signals from the following sources: (1) a radiation detector (diode array); (2) a Keithley kV divider (Keithley Instruments, Inc.); (3) the video output of an image intensifier system. (author)

  6. Challenges of measuring quality in emergency management

    DEFF Research Database (Denmark)

    Lynette, Jennifer Elyse

    2016-01-01

    This paper describes the challenges and importance of measuring quality within the field of emergency response. Using quality as a standard of measurement to evaluate response efforts of trained personnel in emergency situations is necessary to increase effectiveness in the response phase...... of an emergency event. The intended outcome of utilizing quality as a tool of measurement is to save additional lives, property, and resources. The adoption of a system to measure quality can be utilized by multiple professions under the broader field of emergency response services. Quality is discussed in terms...

  7. Quality assurance handbook for measurement laboratories

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1984-10-01

    This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining quality data and the importance of such data are discussed. Chapter 2 presents the elements of laboratory quality assurance in terms of practices that can be used in controlling work activities to assure the acquisition of quality data. Chapter 3 discusses the implementation of laboratory quality assurance. The appendices provide supplemental information to give the users a better understanding of the following: what is quality assurance; why quality assurance is required; where quality assurance requirements come from; how those requirements are interpreted for application to laboratory operations; how the elements of laboratory quality assurance relate to various laboratory activities; and how a quality assurance program can be developed

  8. Infrared Video Pupillography Coupled with Smart Phone LED for Measurement of Pupillary Light Reflex.

    Science.gov (United States)

    Chang, Lily Yu-Li; Turuwhenua, Jason; Qu, Tian Yuan; Black, Joanna M; Acosta, Monica L

    2017-01-01

    Clinical assessment of pupil appearance and pupillary light reflex (PLR) may inform us the integrity of the autonomic nervous system (ANS). Current clinical pupil assessment is limited to qualitative examination, and relies on clinical judgment. Infrared (IR) video pupillography combined with image processing software offer the possibility of recording quantitative parameters. In this study we describe an IR video pupillography set-up intended for human and animal testing. As part of the validation, resting pupil diameter was measured in human subjects using the NeurOptics ™ (Irvine, CA, USA) pupillometer, to compare against that measured by our IR video pupillography set-up, and PLR was assessed in guinea pigs. The set-up consisted of a smart phone with a light emitting diode (LED) strobe light (0.2 s light ON, 5 s light OFF cycles) as the stimulus and an IR camera to record pupil kinetics. The consensual response was recorded, and the video recording was processed using a custom MATLAB program. The parameters assessed were resting pupil diameter (D1), constriction velocity (CV), percentage constriction ratio, re-dilation velocity (DV) and percentage re-dilation ratio. We report that the IR video pupillography set-up provided comparable results as the NeurOptics ™ pupillometer in human subjects, and was able to detect larger resting pupil size in juvenile male guinea pigs compared to juvenile female guinea pigs. At juvenile age, male guinea pigs also had stronger pupil kinetics for both pupil constriction and dilation. Furthermore, our IR video pupillography set-up was able to detect an age-specific increase in pupil diameter (female guinea pigs only) and reduction in CV (male and female guinea pigs) as animals developed from juvenile (3 months) to adult age (7 months). This technique demonstrated accurate and quantitative assessment of pupil parameters, and may provide the foundation for further development of an integrated system useful for clinical

  9. Preliminary study on effects of 60Co γ-irradiation on video quality and the image de-noising methods

    International Nuclear Information System (INIS)

    Yuan Mei; Zhao Jianbin; Cui Lei

    2011-01-01

    There will be variable noises appear on images in video once the play device irradiated by γ-rays, so as to affect the image clarity. In order to eliminate the image noising, the affection mechanism of γ-irradiation on video-play device was studied in this paper and the methods to improve the image quality with both hardware and software were proposed by use of protection program and de-noising algorithm. The experimental results show that the scheme of video de-noising based on hardware and software can improve effectively the PSNR by 87.5 dB. (authors)

  10. Policy responses to problematic video game use: A systematic review of current measures and future possibilities.

    Science.gov (United States)

    Király, Orsolya; Griffiths, Mark D; King, Daniel L; Lee, Hae-Kook; Lee, Seung-Yup; Bányai, Fanni; Zsila, Ágnes; Takacs, Zsofia K; Demetrovics, Zsolt

    2017-09-01

    Background and aims Empirical research into problematic video game playing suggests that overuse might cause functional and psychological impairments for a minority of gamers. Therefore, the need for regulation in the case of video games (whether governmental or self-imposed) has arisen but has only been implemented in a few countries around the world, and predominantly in Asia. This paper provides a systematic review of current and potential policies addressing problematic gaming. Methods After conducting a systematic search in the areas of prevention, treatment, and policy measures relating to problematic Internet and video game use, papers were selected that targeted problematic gaming policies (N = 12; six in English and six in Korean). These papers served as the basis of this review. Results Policies were classified into three major groups: (i) policy measures limiting availability of video games (e.g., shutdown policy, fatigue system, and parental controls), (ii) measures aiming to reduce risk and harm (e.g., warning messages), and (iii) measures taken to provide help services for gamers. Beyond the attempt to classify the current and potential policy measures, the authors also tried to evaluate their efficiency theoretically and (if data were available) empirically. Discussion and conclusions Overall, it appears that although several steps have been taken to address problematic video game playing, most of these steps were not as effective as expected, or had not been evaluated empirically for efficacy. The reason for this may lie in the fact that the policies outlined only addressed or influenced specific aspects of the problem instead of using a more integrative approach.

  11. Modeling the Quality of Videos Displayed With Local Dimming Backlight at Different Peak White and Ambient Light Levels

    DEFF Research Database (Denmark)

    Mantel, Claire; Søgaard, Jacob; Bech, Søren

    2016-01-01

    is computed using a model of the display. Widely used objective quality metrics are applied based on the rendering models of the videos to predict the subjective evaluations. As these predictions are not satisfying, three machine learning methods are applied: partial least square regression, elastic net......This paper investigates the impact of ambient light and peak white (maximum brightness of a display) on the perceived quality of videos displayed using local backlight dimming. Two subjective tests providing quality evaluations are presented and analyzed. The analyses of variance show significant...

  12. The next generation borescope -- Video imaging measurement systems as portable as a fiberscope

    International Nuclear Information System (INIS)

    Boyd, C.E.

    1994-01-01

    Today, Remote Visual Inspection (RVI) techniques routinely save industry the significant costs associated with unscheduled shutdowns and equipment disassembly by enabling visual inspection of otherwise inaccessible equipment surfaces with instruments called borescopes. Specific applications in the nuclear industry include heat exchangers, condensers, boiler tubes, steam generators, headers, and other general interior surface inspections. While borescope inspections have achieved widespread utility, their potential applicability and value have been limited by their inability to provide dimensional information about the objects seen. This paper presents a simple, but very accurate measurement technique that enables the inspector to make measurements of objects directly from the borescope image. While used effectively since 1990, the technique is designed for a video imaging borescope and has, therefore, not been available for the shorter length fiberscope applications--until now. On June 6, 1993 Welch Allyn introduced the VideoProbe XL, a video imaging borescope that is as portable and affordable as a one meter fiberscope. This breakthrough not only extends video imaging into the rest of the fiberscope world, but opens the door for them to this measurement capability as well

  13. Image-scanning measurement using video dissection cameras

    International Nuclear Information System (INIS)

    Carson, J.S.

    1978-01-01

    A high speed dimensional measuring system capable of scanning a thin film network, and determining if there are conductor widths, resistor widths, or spaces not typical of the design for this product is described. The eye of the system is a conventional TV camera, although such devices as image dissector cameras or solid-state scanners may be used more often in the future. The analog signal from the TV camera is digitized for processing by the computer and is presented to the TV monitor to assist the operator in monitoring the system's operation. Movable stages are required when the field of view of the scanner is less than the size of the object. A minicomputer controls the movement of the stage, and communicates with the digitizer to select picture points that are to be processed. Communications with the system are maintained through a teletype or CRT terminal

  14. Measures of behavioral function predict duration of video game play: Utilization of the Video Game Functional Assessment - Revised.

    Science.gov (United States)

    Buono, Frank D; Griffiths, Mark D; Sprong, Matthew E; Lloyd, Daniel P; Sullivan, Ryan M; Upton, Thomas D

    2017-12-01

    Background Internet gaming disorder (IGD) was introduced in the DSM-5 as a way of identifying and diagnosing problematic video game play. However, the use of the diagnosis is constrained, as it shares criteria with other addictive orders (e.g., pathological gambling). Aims Further work is required to better understand IGD. One potential avenue of investigation is IGD's relationship to the primary reinforcing behavioral functions. This study explores the relationship between duration of video game play and the reinforcing behavioral functions that may motivate or maintain video gaming. Methods A total of 499 video game players began the online survey, with complete data from 453 participants (85% white and 28% female), were analyzed. Individuals were placed into five groups based on self-reported hours of video gaming per week, and completed the Video Game Functional Assessment - Revised (VGFA-R). Results The results demonstrated the escape and social attention function were significant in predicting duration of video game play, whereas sensory and tangible were not significant. Conclusion Future implications of the VGFA-R and behaviorally based research are discussed.

  15. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  16. Multi-frame super-resolution with quality self-assessment for retinal fundus videos.

    Science.gov (United States)

    Köhler, Thomas; Brost, Alexander; Mogalle, Katja; Zhang, Qianyi; Köhler, Christiane; Michelson, Georg; Hornegger, Joachim; Tornow, Ralf P

    2014-01-01

    This paper proposes a novel super-resolution framework to reconstruct high-resolution fundus images from multiple low-resolution video frames in retinal fundus imaging. Natural eye movements during an examination are used as a cue for super-resolution in a robust maximum a-posteriori scheme. In order to compensate heterogeneous illumination on the fundus, we integrate retrospective illumination correction for photometric registration to the underlying imaging model. Our method utilizes quality self-assessment to provide objective quality scores for reconstructed images as well as to select regularization parameters automatically. In our evaluation on real data acquired from six human subjects with a low-cost video camera, the proposed method achieved considerable enhancements of low-resolution frames and improved noise and sharpness characteristics by 74%. In terms of image analysis, we demonstrate the importance of our method for the improvement of automatic blood vessel segmentation as an example application, where the sensitivity was increased by 13% using super-resolution reconstruction.

  17. Measuring earnings quality: Evidence from New Zealand

    Directory of Open Access Journals (Sweden)

    Muhammad Nurul Houqe

    2011-01-01

    Full Text Available We utilize two basic approaches to measure the quality of earnings which control two different dimensions of earnings management. The research design is structured primary on the basis of calculating two different measures of the quality of earnings on the industry level and on the company level. We calculate earnings quality for New Zealand public firms from the OSIRIS (http://www.osiris.com database for 2004-2007. This research concludes that various stakeholders should apply more than one measure for the quality of earning in order to have strong evidence about the level of quality before taking any corrective action or making any decision related to that company. If one company is having low quality of earning according to one technique and high quality of earnings according to another, the stakeholders cannot have a final conclusion about that company and they need more investigations and analysis to assess the quality of earnings

  18. Measuring healthcare quality: the challenges

    NARCIS (Netherlands)

    van den Heuvel, J.; Niemeijer, G.C.; Does, R.J.M.M.

    2013-01-01

    Purpose - Current health care quality performance indicators appear to be inadequate to inform the public to make the right choices. The aim of this paper is to define a framework and an organizational setting in which valid and reliable healthcare information can be produced to inform the general

  19. Non-mydriatic video ophthalmoscope to measure fast temporal changes of the human retina

    Science.gov (United States)

    Tornow, Ralf P.; Kolář, Radim; Odstrčilík, Jan

    2015-07-01

    The analysis of fast temporal changes of the human retina can be used to get insight to normal physiological behavior and to detect pathological deviations. This can be important for the early detection of glaucoma and other eye diseases. We developed a small, lightweight, USB powered video ophthalmoscope that allows taking video sequences of the human retina with at least 25 frames per second without dilating the pupil. Short sequences (about 10 s) of the optic nerve head (20° x 15°) are recorded from subjects and registered offline using two-stage process (phase correlation and Lucas-Kanade approach) to compensate for eye movements. From registered video sequences, different parameters can be calculated. Two applications are described here: measurement of (i) cardiac cycle induced pulsatile reflection changes and (ii) eye movements and fixation pattern. Cardiac cycle induced pulsatile reflection changes are caused by changing blood volume in the retina. Waveform and pulse parameters like amplitude and rise time can be measured in any selected areas within the retinal image. Fixation pattern ΔY(ΔX) can be assessed from eye movements during video acquisition. The eye movements ΔX[t], ΔY[t] are derived from image registration results with high temporal (40 ms) and spatial (1,86 arcmin) resolution. Parameters of pulsatile reflection changes and fixation pattern can be affected in beginning glaucoma and the method described here may support early detection of glaucoma and other eye disease.

  20. Measurement of the Dynamic Displacements of Railway Bridges Using Video Technology

    Directory of Open Access Journals (Sweden)

    Ribeiro Diogo

    2015-01-01

    Full Text Available This article describes the development of a non-contact dynamic displacement measurement system for railway bridges based on video technology. The system, consisting of a high speed video camera, an optical lens, lighting lamps and a precision target, can perform measurements with high precision for distances from the camera to the target up to 25 m, with acquisition frame rates ranging from 64 fps to 500 fps, and be articulated with other measurement systems, which promotes its integration in structural health monitoring systems. The system’s performance was evaluated based on two tests, one in the laboratory and other on the field. The laboratory test evaluated the performance of the system in measuring the displacement of a steel beam, subjected to a point load applied dynamically, for distances from the camera to the target between 3 m and 15 m. The field test allowed evaluating the system’s performance in the dynamic measurement of the displacement of a point on the deck of a railway bridge, induced by passing trains at speeds between 160 km/h and 180 km/h, for distances from the camera to the target up to 25 m. The results of both tests show a very good agreement between the displacement measurement obtained with the video system and with a LVDT.

  1. Development of a Coding Instrument to Assess the Quality and Content of Anti-Tobacco Video Games

    Science.gov (United States)

    Alber, Julia M.; Watson, Anna M.; Barnett, Tracey E.; Mercado, Rebeccah

    2015-01-01

    Abstract Previous research has shown the use of electronic video games as an effective method for increasing content knowledge about the risks of drugs and alcohol use for adolescents. Although best practice suggests that theory, health communication strategies, and game appeal are important characteristics for developing games, no instruments are currently available to examine the quality and content of tobacco prevention and cessation electronic games. This study presents the systematic development of a coding instrument to measure the quality, use of theory, and health communication strategies of tobacco cessation and prevention electronic games. Using previous research and expert review, a content analysis coding instrument measuring 67 characteristics was developed with three overarching categories: type and quality of games, theory and approach, and type and format of messages. Two trained coders applied the instrument to 88 games on four platforms (personal computer, Nintendo DS, iPhone, and Android phone) to field test the instrument. Cohen's kappa for each item ranged from 0.66 to 1.00, with an average kappa value of 0.97. Future research can adapt this coding instrument to games addressing other health issues. In addition, the instrument questions can serve as a useful guide for evidence-based game development. PMID:26167842

  2. Development of a Coding Instrument to Assess the Quality and Content of Anti-Tobacco Video Games.

    Science.gov (United States)

    Alber, Julia M; Watson, Anna M; Barnett, Tracey E; Mercado, Rebeccah; Bernhardt, Jay M

    2015-07-01

    Previous research has shown the use of electronic video games as an effective method for increasing content knowledge about the risks of drugs and alcohol use for adolescents. Although best practice suggests that theory, health communication strategies, and game appeal are important characteristics for developing games, no instruments are currently available to examine the quality and content of tobacco prevention and cessation electronic games. This study presents the systematic development of a coding instrument to measure the quality, use of theory, and health communication strategies of tobacco cessation and prevention electronic games. Using previous research and expert review, a content analysis coding instrument measuring 67 characteristics was developed with three overarching categories: type and quality of games, theory and approach, and type and format of messages. Two trained coders applied the instrument to 88 games on four platforms (personal computer, Nintendo DS, iPhone, and Android phone) to field test the instrument. Cohen's kappa for each item ranged from 0.66 to 1.00, with an average kappa value of 0.97. Future research can adapt this coding instrument to games addressing other health issues. In addition, the instrument questions can serve as a useful guide for evidence-based game development.

  3. Are we really measuring what we say we're measuring? Using video techniques to supplement traditional construct validation procedures.

    Science.gov (United States)

    Podsakoff, Nathan P; Podsakoff, Philip M; Mackenzie, Scott B; Klinger, Ryan L

    2013-01-01

    Several researchers have persuasively argued that the most important evidence to consider when assessing construct validity is whether variations in the construct of interest cause corresponding variations in the measures of the focal construct. Unfortunately, the literature provides little practical guidance on how researchers can go about testing this. Therefore, the purpose of this article is to describe how researchers can use video techniques to test whether their scales measure what they purport to measure. First, we discuss how researchers can develop valid manipulations of the focal construct that they hope to measure. Next, we explain how to design a study to use this manipulation to test the validity of the scale. Finally, comparing and contrasting traditional and contemporary perspectives on validation, we discuss the advantages and limitations of video-based validation procedures. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  4. Computer controlled quality of analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  5. Achieving software quality by GQM measurement

    NARCIS (Netherlands)

    Solingen, van D.M.; Veenendaal, van E.P.W.M.; Veenendaal, van E.P.W.M.; McMullan, J.

    1997-01-01

    Software development is a discipline with specific management difficulties. Collecting relevant data during development is a way to overcome these difficulties. Such data collection for sqftware development is termed "Software Measurement". Software measurement is a powerful aid to quality

  6. History and background of quality measurement.

    Science.gov (United States)

    Chun, Jonathan; Bafford, Andrea Chao

    2014-03-01

    Health care quality measurement has become increasingly emphasized, as providers and administrators respond to public and government demands for improved patient care. This article will review the evolution of surgical quality measurement and improvement from its infancy in the 1850s to the vast efforts being undertaken today.

  7. Availability of high quality weather data measurements

    DEFF Research Database (Denmark)

    Andersen, Elsa; Johansen, Jakob Berg; Furbo, Simon

    In the period 2016-2017 the project “Availability of high quality weather data measurements” is carried out at Department of Civil Engineering at the Technical University of Denmark. The aim of the project is to establish measured high quality weather data which will be easily available...... for the building energy branch and the solar energy branch in their efforts to achieve energy savings and for researchers and students carrying out projects where measured high quality weather data are needed....

  8. Fourier transform based scalable image quality measure.

    Science.gov (United States)

    Narwaria, Manish; Lin, Weisi; McLoughlin, Ian; Emmanuel, Sabu; Chia, Liang-Tien

    2012-08-01

    We present a new image quality assessment (IQA) algorithm based on the phase and magnitude of the 2D (twodimensional) Discrete Fourier Transform (DFT). The basic idea is to compare the phase and magnitude of the reference and distorted images to compute the quality score. However, it is well known that the Human Visual Systems (HVSs) sensitivity to different frequency components is not the same. We accommodate this fact via a simple yet effective strategy of nonuniform binning of the frequency components. This process also leads to reduced space representation of the image thereby enabling the reduced-reference (RR) prospects of the proposed scheme. We employ linear regression to integrate the effects of the changes in phase and magnitude. In this way, the required weights are determined via proper training and hence more convincing and effective. Lastly, using the fact that phase usually conveys more information than magnitude, we use only the phase for RR quality assessment. This provides the crucial advantage of further reduction in the required amount of reference image information. The proposed method is therefore further scalable for RR scenarios. We report extensive experimental results using a total of 9 publicly available databases: 7 image (with a total of 3832 distorted images with diverse distortions) and 2 video databases (totally 228 distorted videos). These show that the proposed method is overall better than several of the existing fullreference (FR) algorithms and two RR algorithms. Additionally, there is a graceful degradation in prediction performance as the amount of reference image information is reduced thereby confirming its scalability prospects. To enable comparisons and future study, a Matlab implementation of the proposed algorithm is available at http://www.ntu.edu.sg/home/wslin/reduced_phase.rar.

  9. Candidate Quality Measures for Hand Surgery.

    Science.gov (United States)

    2017-11-01

    Quality measures are tools used by physicians, health care systems, and payers to evaluate performance, monitor the outcomes of interventions, and inform quality improvement efforts. A paucity of quality measures exist that address hand surgery care. We completed a RAND/UCLA (University of California Los Angeles) Delphi Appropriateness process with the goal of developing and evaluating candidate hand surgery quality measures to be used for national quality measure development efforts. A consortium of 9 academic upper limb surgeons completed a RAND/UCLA Delphi Appropriateness process to evaluate the importance, scientific acceptability, usability, and feasibility of 44 candidate quality measures. These addressed hand problems the panelists felt were most appropriate for quality measure development. Panelists rated the measures on an ordinal scale between 1 (definitely not valid) and 9 (definitely valid) in 2 rounds (preliminary round and final round) with an intervening face-to-face discussion. Ratings from 1 to 3 were considered not valid, 4 to 6 as equivocal or uncertain, and 7 to 9 as valid. If no more than 2 of the 9 ratings were outside the 3-point range that included the median (1-3, 4-6, or 7-9), the panelists were considered to be in agreement. If 3 or more of the panelists' ratings of a measure were within the 1 to 3 range and 3 or more ratings were in the 7 to 9 range, the panelists were considered to be in disagreement. There was agreement on 43% (19) of the measures as important, 27% (12) as scientifically sound, 48% (21) as usable, and 59% (26) as feasible to complete. Ten measures met all 4 of these criteria and were, therefore, considered valid measurements of quality. Quality measures that were developed address outcomes (patient-reported outcomes for assessment and improvement of function) and processes of care (utilization rates of imaging, antibiotics, occupational therapy, ultrasound, and operative treatment). The consortium developed 10

  10. Earnings Quality Measures and Excess Returns.

    Science.gov (United States)

    Perotti, Pietro; Wagenhofer, Alfred

    2014-06-01

    This paper examines how commonly used earnings quality measures fulfill a key objective of financial reporting, i.e., improving decision usefulness for investors. We propose a stock-price-based measure for assessing the quality of earnings quality measures. We predict that firms with higher earnings quality will be less mispriced than other firms. Mispricing is measured by the difference of the mean absolute excess returns of portfolios formed on high and low values of a measure. We examine persistence, predictability, two measures of smoothness, abnormal accruals, accruals quality, earnings response coefficient and value relevance. For a large sample of US non-financial firms over the period 1988-2007, we show that all measures except for smoothness are negatively associated with absolute excess returns, suggesting that smoothness is generally a favorable attribute of earnings. Accruals measures generate the largest spread in absolute excess returns, followed by smoothness and market-based measures. These results lend support to the widespread use of accruals measures as overall measures of earnings quality in the literature.

  11. Quality measures for nurse practitioner practice evaluation.

    Science.gov (United States)

    Kleinpell, Ruth; Kapu, April N

    2017-08-01

    Evaluating the impact of nurse practitioner (NP) practice has become a priority area of focus for demonstrating outcomes. A number of quality measures are available to enable practice-specific evaluation of NP roles and initiatives. This article reviews sources of quality measures that can be used to facilitate quantifying the outcomes of NP practice as part of an overall evaluation agenda. National resources and published literature on NP quality measures were reviewed. Various resources and toolkits exist to assist NPs in identifying outcomes of practice using quality measures. The need to demonstrate outcomes of NP practice remains an ongoing priority area regardless of the clinical practice setting. A variety of sources of quality measures exist that can be used to showcase the effect of NP care. The use of quality measures can be effectively integrated into evaluation of NP role and NP-directed initiatives to demonstrate impact, and enhance the conduct of an NP outcomes assessment. The use of organizational, NP-specific, and national-related quality measures can help to showcase how NP care improves the quality, safety, and costs of health care. ©2017 American Association of Nurse Practitioners.

  12. Quality assurance in radiation measurement

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2002-01-01

    The achievement of traceability to recognize measurement standards for ionizing radiation posses special requirements. Methods of transferring reference standard to the working situation are devised through calibration and appropriate traceability, which optimize the accuracy attainable with the method of dose determination in routine use. Appropriate procedures are developed by the SSDL-MINT to establish accurate dose measurement in wide range of radiation fields such as in medicine, agriculture and industrial application. The status of work including effort towards ISO 9000 certification of SSDL dosimetry services will be summarized. (Author)

  13. Reconstruction of Huygens' gedanken experiment and measurements based on video analysis tools

    International Nuclear Information System (INIS)

    Malgieri, Massimiliano; Onorato, Pasquale; Mascheretti, Paolo; De Ambrosis, Anna

    2013-01-01

    In this paper we describe the practical realization and the analysis of a thought experiment devised by Christiaan Huygens, which was pivotal in his derivation of the formula for the radius of gyration of a compound pendulum. Measurements are realized by recording the experiment with a digital camera, and using a video analysis and modelling software tool to process and extract information from the acquired videos. Using this setup, detailed quantitative comparisons between measurements and theoretical predictions can be carried out, focusing on many relevant topics in the undergraduate physics curriculum, such as the ‘radius of gyration’, conservation of energy, moment of inertia, constraint and reaction forces, and the behaviour of the centre of mass. (paper)

  14. [Quality measurement using administrative data in mandatory quality assurance].

    Science.gov (United States)

    Heller, Günther; Szecsenyi, Joachim; Willms, Gerald; Broge, Björn

    2014-01-01

    For several years, the use of administrative data in mandatory quality measurement has been requested by several stakeholders in Germany. Main advantages of using administrative data include the reduction of documentary expenditures and the possibility to perform longitudinal quality analyses across different healthcare units. After a short introduction, a brief overview of the current use of administrative data for mandatory quality assurance as well as current developments is given, which will then be further exemplified by decubital ulcer prophylaxis. By using administrative data coding expenditures in this clinical area could be reduced by nine million data fields. At the same time the population analysed was expanded resulting in a more than tenfold increase in potentially quality-relevant events. Finally, perspectives, further developments, possibilities as well as limits of quality measurement with administrative data are discussed. Copyright © 2014. Published by Elsevier GmbH.

  15. Need for quality dose measurements

    International Nuclear Information System (INIS)

    Forbes, J.L.

    1985-01-01

    Work procedures based upon dependable measurements have unquestionably reduced past exposures to a level that will produce few injuries in later years. Of the many legal issues that might be discussed with regard to instrument calibration, the two of present concern are the determination of cause, and the evidence (including expert testimony) submitted to that end. Although they are termed here legal issues, they are in fact highly technical problems which have recently become political footballs. Some background is discussed in order to understand how such legal/technical/political considerations are related to instrument calibration, the subject of this workshop

  16. Quality improvement in neurology: AAN Parkinson disease quality measures

    Science.gov (United States)

    Cheng, E.M.; Tonn, S.; Swain-Eng, R.; Factor, S.A.; Weiner, W.J.; Bever, C.T.

    2010-01-01

    Background: Measuring the quality of health care is a fundamental step toward improving health care and is increasingly used in pay-for-performance initiatives and maintenance of certification requirements. Measure development to date has focused on primary care and common conditions such as diabetes; thus, the number of measures that apply to neurologic care is limited. The American Academy of Neurology (AAN) identified the need for neurologists to develop measures of neurologic care and to establish a process to accomplish this. Objective: To adapt and test the feasibility of a process for independent development by the AAN of measures for neurologic conditions for national measurement programs. Methods: A process that has been used nationally for measure development was adapted for use by the AAN. Topics for measure development are chosen based upon national priorities, available evidence base from a systematic literature search, gaps in care, and the potential impact for quality improvement. A panel composed of subject matter and measure development methodology experts oversees the development of the measures. Recommendation statements and their corresponding level of evidence are reviewed and considered for development into draft candidate measures. The candidate measures are refined by the expert panel during a 30-day public comment period and by review by the American Medical Association for Current Procedural Terminology (CPT) II codes. All final AAN measures are approved by the AAN Board of Directors. Results: Parkinson disease (PD) was chosen for measure development. A review of the medical literature identified 258 relevant recommendation statements. A 28-member panel approved 10 quality measures for PD that included full specifications and CPT II codes. Conclusion: The AAN has adapted a measure development process that is suitable for national measurement programs and has demonstrated its capability to independently develop quality measures. GLOSSARY

  17. Quality measurement and improvement in liver transplantation.

    Science.gov (United States)

    Mathur, Amit K; Talwalkar, Jayant

    2018-06-01

    There is growing interest in the quality of health care delivery in liver transplantation. Multiple stakeholders, including patients, transplant providers and their hospitals, payers, and regulatory bodies have an interest in measuring and monitoring quality in the liver transplant process, and understanding differences in quality across centres. This article aims to provide an overview of quality measurement and regulatory issues in liver transplantation performed within the United States. We review how broader definitions of health care quality should be applied to liver transplant care models. We outline the status quo including the current regulatory agencies, public reporting mechanisms, and requirements around quality assurance and performance improvement (QAPI) activities. Additionally, we further discuss unintended consequences and opportunities for growth in quality measurement. Quality measurement and the integration of quality improvement strategies into liver transplant programmes hold significant promise, but multiple challenges to successful implementation must be addressed to optimise value. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  18. Cross-Layer Measurement on an IEEE 802.11g Wireless Network Supporting MPEG-2 Video Streaming Applications in the Presence of Interference

    Directory of Open Access Journals (Sweden)

    Alessandro Sona

    2010-01-01

    Full Text Available The performance of wireless local area networks supporting video streaming applications, based on MPEG-2 video codec, in the presence of interference is here dealt with. IEEE 802.11g standard wireless networks, that do not support QoS in according with IEEE 802.11e standard, are, in particular, accounted for and Bluetooth signals, additive white Gaussian noise, and competitive data traffic are considered as sources of interference. The goal is twofold: from one side, experimentally assessing and correlating the values that some performance metrics assume at the same time at different layers of an IEEE 802.11g WLAN delivering video streaming in the presence of in-channel interference; from the other side, deducing helpful and practical hints for designers and technicians, in order to efficiently assess and enhance the performance of an IEEE 802.11g WLAN supporting video streaming in some suitable setup conditions and in the presence of interference. To this purpose, an experimental analysis is planned following a cross-layer measurement approach, and a proper testbed within a semianechoic chamber is used. Valuable results are obtained in terms of signal-to-interference ratio, packet loss ratio, jitter, video quality, and interference data rate; helpful hints for designers and technicians are finally gained.

  19. Measuring effectiveness of food quality management

    OpenAIRE

    Spiegel, van der, M.

    2004-01-01

    Keywords: effectiveness, food quality management, instrument, quality performance, contextual factors, agri-food production, conceptual model, performance measurement indicators, identification, validation, assessment, quality assurance systems, QA systems, HACCP, Hygiene code, ISO, BRC, GMP, bakery sector.In the last decade several incidents have occurred in the agri-food sector, such as the affairs of dioxin and BSE, whereas also the incidence of food-borne diseases and the production of hi...

  20. Behind the NAT – A Measurement Based Evaluation of Cellular Service Quality

    OpenAIRE

    Kaup, Fabian; Michelinakis, Foivos; Bui, Nicola; Widmer, Joerg; Wac, Katarzyna; Hausheer, David

    2015-01-01

    Abstract—Mobile applications such as VoIP, (live) gaming, or video streaming have diverse QoS requirements ranging from low delay to high throughput. The optimization of the network quality experienced by end-users requires detailed knowledge of the expected network performance. Also, the achieved service quality is affected by a number of factors, including network operator and available technologies. However, most studies focusing on measuring the cellular network do not consider the perfor...

  1. Subjective quality of videos displayed with local backlight dimming at different peak white and ambient light levels

    DEFF Research Database (Denmark)

    Mantel, Claire; Korhonen, Jari; Forchhammer, Søren

    2015-01-01

    In this paper the influence of ambient light and peak white (maximum brightness) of a display on the subjective quality of videos shown with local backlight dimming is examined. A subjective experiment investigating those factors is set-up using high contrast test sequences. The results are firstly...

  2. A Linear Algebra Measure of Cluster Quality.

    Science.gov (United States)

    Mather, Laura A.

    2000-01-01

    Discussion of models for information retrieval focuses on an application of linear algebra to text clustering, namely, a metric for measuring cluster quality based on the theory that cluster quality is proportional to the number of terms that are disjoint across the clusters. Explains term-document matrices and clustering algorithms. (Author/LRW)

  3. Measuring Service Quality in a Tertiary Institution.

    Science.gov (United States)

    Soutar, Geoffrey; McNeil, Margaret

    1996-01-01

    Measures service quality from the viewpoint of customers (students at an Australian university), using the SERVQUAL model. Obtains evaluations of academic and administrative aspects of the educational service. Makes significant negative evaluations of administrative service quality (resulting from communication problems). Satisfaction with the…

  4. External quality measurements reveal internal processes

    NARCIS (Netherlands)

    Schouten, R.E.; Costa, J.M.; Kooten, van O.

    2003-01-01

    With the present developments in CA technology it becomes possible to fine tune the storage conditions to the specific needs of the product. This generates the need to know the exact quality conditions of the product before storage starts. By measuring the initial quality we can determine these

  5. Measurement of interfacial tension by use of pendant drop video techniques

    Science.gov (United States)

    Herd, Melvin D.; Thomas, Charles P.; Bala, Gregory A.; Lassahn, Gordon D.

    1993-09-01

    This report describes an instrument to measure the interfacial tension (IFT) of aqueous surfactant solutions and crude oil. The method involves injection of a drop of fluid (such as crude oil) into a second immiscible phase to determine the IFT between the two phases. The instrument is composed of an AT-class computer, optical cell, illumination, video camera and lens, video frame digitizer board, monitor, and software. The camera displays an image of the pendant drop on the monitor, which is then processed by the frame digitizer board and non-proprietary software to determine the IFT. Several binary and ternary phase systems were taken from the literature and used to measure the precision and accuracy of the instrument in determining IFT's. A copy of the software program is included in the report. A copy of the program on diskette can be obtained from the Energy Science and Technology Software Center, P.O. Box 1020, Oak Ridge, TN 37831-1020. The accuracy and precision of the technique and apparatus presented is very good for measurement of IFT's in the range from 72 to 10(exp -2) mN/m, which is adequate for many EOR applications. With modifications to the equipment and the numerical techniques, measurements of ultralow IFT's (less than 10(exp -3) mN/m) should be possible as well as measurements at reservoir temperature and pressure conditions. The instrument has been used at the Idaho National Engineering Laboratory to support the research program on microbial enhanced oil recovery. Measurements of IFT's for several bacterial supernatants and unfractionated acid precipitates of microbial cultures containing biosurfactants against medium to heavy crude oils are reported. These experiments demonstrate that the use of automated video imaging of pendant drops is a simple and fast method to reliably determine interfacial tension between two immiscible liquid phases, or between a gas and a liquid phase.

  6. Business Process Modelling for Measuring Quality

    NARCIS (Netherlands)

    Heidari, F.; Loucopoulos, P.; Brazier, F.M.

    2013-01-01

    Business process modelling languages facilitate presentation, communication and analysis of business processes with different stakeholders. This paper proposes an approach that drives specification and measurement of quality requirements and in doing so relies on business process models as

  7. Braking Deceleration Measurement Using the Video Analysis of Motions by Sw Tracker

    Directory of Open Access Journals (Sweden)

    Ondruš Ján

    2015-06-01

    Full Text Available This contribution deals with the issue of car braking, particularly with the one of M1 category. Braking deceleration measurement of the vehicle Mazda 3 MPS was carried out by the declerograph XL MeterTM Pro. The main aim of the contribution is to perform comparison of the process of braking deceleration between the decelograph and the new alternative method of video analysis and to subsequently examine these processes. The test took place at the Rosina airfield, the airstrip in a small village nearby the town of Žilina. The last part of this paper presents the results, evlauation and comparison of the measurements carried out.

  8. Transport services quality measurment using SERVQUAL model

    Directory of Open Access Journals (Sweden)

    Maksimović Mlađan V.

    2017-01-01

    Full Text Available Quality in the world is considered to be the most important phenomenon of our age, with a permanent and irreversible growing trend of its emphasis. Many companies have come to the conclusion that high quality of services can provide them with a potential competitive advantage, leading to superior sales results and profit making. The aim of this paper is to test the applicability of service SERVQUAL dimensions and measure the quality of services in the public transport of passengers. Based on the data obtained by researching the views of public transport users in Kragujevac using the SERVQUAL methodology and statistical analysis based on defined service quality dimensions, this research will show the level of quality of urban transport services in Kragujevac and based on this, make recommendations for improving the quality of service.

  9. [Comparative quality measurements part 3: funnel plots].

    Science.gov (United States)

    Kottner, Jan; Lahmann, Nils

    2014-02-01

    Comparative quality measurements between organisations or institutions are common. Quality measures need to be standardised and risk adjusted. Random error must also be taken adequately into account. Rankings without consideration of the precision lead to flawed interpretations and enhances "gaming". Application of confidence intervals is one possibility to take chance variation into account. Funnel plots are modified control charts based on Statistical Process Control (SPC) theory. The quality measures are plotted against their sample size. Warning and control limits that are 2 or 3 standard deviations from the center line are added. With increasing group size the precision increases and so the control limits are forming a funnel. Data points within the control limits are considered to show common cause variation; data points outside special cause variation without the focus of spurious rankings. Funnel plots offer data based information about how to evaluate institutional performance within quality management contexts.

  10. High-quality and small-capacity e-learning video featuring lecturer-superimposing PC screen images

    Science.gov (United States)

    Nomura, Yoshihiko; Murakami, Michinobu; Sakamoto, Ryota; Sugiura, Tokuhiro; Matsui, Hirokazu; Kato, Norihiko

    2006-10-01

    Information processing and communication technology are progressing quickly, and are prevailing throughout various technological fields. Therefore, the development of such technology should respond to the needs for improvement of quality in the e-learning education system. The authors propose a new video-image compression processing system that ingeniously employs the features of the lecturing scene. While dynamic lecturing scene is shot by a digital video camera, screen images are electronically stored by a PC screen image capturing software in relatively long period at a practical class. Then, a lecturer and a lecture stick are extracted from the digital video images by pattern recognition techniques, and the extracted images are superimposed on the appropriate PC screen images by off-line processing. Thus, we have succeeded to create a high-quality and small-capacity (HQ/SC) video-on-demand educational content featuring the advantages: the high quality of image sharpness, the small electronic file capacity, and the realistic lecturer motion.

  11. Measurement system of bubbly flow using ultrasonic velocity profile monitor and video data processing unit

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Zhou, Shirong; Nakajima, Makoto; Takeda, Yasushi; Mori, Michitsugu; Yoshioka, Yuzuru.

    1996-01-01

    The authors have been developing a measurement system for bubbly flow in order to clarify its multi-dimensional flow characteristics and to offer a data base to validate numerical codes for multi-dimensional two-phase flow. In this paper, the measurement system combining an ultrasonic velocity profile monitor with a video data processing unit is proposed, which can measure simultaneously velocity profiles in both gas and liquid phases, a void fraction profile for bubbly flow in a channel, and an average bubble diameter and void fraction. Furthermore, the proposed measurement system is applied to measure flow characteristics of a bubbly countercurrent flow in a vertical rectangular channel to verify its capability. (author)

  12. Bulk velocity measurements by video analysis of dye tracer in a macro-rough channel

    International Nuclear Information System (INIS)

    Ghilardi, T; Franca, M J; Schleiss, A J

    2014-01-01

    Steep mountain rivers have hydraulic and morphodynamic characteristics that hinder velocity measurements. The high spatial variability of hydraulic parameters, such as water depth (WD), river width and flow velocity, makes the choice of a representative cross-section to measure the velocity in detail challenging. Additionally, sediment transport and rapidly changing bed morphology exclude the utilization of standard and often intrusive velocity measurement techniques. The limited technical choices are further reduced in the presence of macro-roughness elements, such as large, relatively immobile boulders. Tracer tracking techniques are among the few reliable methods that can be used under these conditions to evaluate the mean flow velocity. However, most tracer tracking techniques calculate bulk flow velocities between two or more fixed cross-sections. In the presence of intense sediment transport resulting in an important temporal variability of the bed morphology, dead water zones may appear in the few selected measurement sections. Thus a technique based on the analysis of an entire channel reach is needed in this study. A dye tracer measurement technique in which a single camcorder visualizes a long flume reach is described and developed. This allows us to overcome the problem of the presence of dead water zones. To validate this video analysis technique, velocity measurements were carried out on a laboratory flume simulating a torrent, with a relatively gentle slope of 1.97% and without sediment transport, using several commonly used velocity measurement instruments. In the absence of boulders, salt injections, WD and ultrasonic velocity profiler measurements were carried out, along with dye injection technique. When boulders were present, dye tracer technique was validated only by comparison with salt tracer. Several video analysis techniques used to infer velocities were developed and compared, showing that dye tracking is a valid technique for bulk velocity

  13. Adopting software quality measures for healthcare processes.

    Science.gov (United States)

    Yildiz, Ozkan; Demirörs, Onur

    2009-01-01

    In this study, we investigated the adoptability of software quality measures for healthcare process measurement. Quality measures of ISO/IEC 9126 are redefined from a process perspective to build a generic healthcare process quality measurement model. Case study research method is used, and the model is applied to a public hospital's Entry to Care process. After the application, weak and strong aspects of the process can be easily observed. Access audibility, fault removal, completeness of documentation, and machine utilization are weak aspects and these aspects are the candidates for process improvement. On the other hand, functional completeness, fault ratio, input validity checking, response time, and throughput time are the strong aspects of the process.

  14. Quality Assurance and Quality Control in TLD Measurement

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  15. Technological measures to improve automotive product quality

    OpenAIRE

    Gladkov, V.; Kruglov, S.

    2010-01-01

    The paper examines the basic technological measures aimed at improving product quality in automotive industry. While paying due attention to solving organizational and technological problems, including the development of certification systems for production processes, it is also necessary to improve the technical standards of specific technologies, equipment and materials as they largely determine product quality. Special emphasis is given to the importance of improving the production of auto...

  16. Transmission Quality Measurements in DAB+ Broadcast System

    Directory of Open Access Journals (Sweden)

    Gilski Przemysław

    2017-12-01

    Full Text Available In the age of digital media, delivering broadcast content to customers at an acceptable level of quality is one of the most challenging tasks. The most important factor is the efficient use of available resources, including bandwidth. An appropriate way of managing the digital multiplex is essential for both the economic and technical issues. In this paper we describe transmission quality measurements in the DAB+ broadcast system. We provide a methodology for analysing parameters and factors related with the efficiency and reliability of a digital radio link. We describe a laboratory stand that can be used for transmission quality assessment on a regional and national level.

  17. Quality assurance measures in interventional radiology

    International Nuclear Information System (INIS)

    Heuser, L.

    1999-01-01

    The quality assurance of treatment measures is legally required but as yet not generally established in practice. For interventional radiology, the introduction of quality assurance for PTA of arteries of the lower limbs is planned for January 1999. It is reasonable to subject at least the most important and/or most frequently performed interventions to quality management. In the present article, the term quality in the management of diseases is defined and the system of total quality management discussed at the levels structure, process, and results. For its application, parameters of quality measurement in the form of standards, criteria, and characteristic values are necessary and must be laid down by a team of experts on the basis of subjective experience and/or results in the literature. Practical quality assurance takes place not only within a clinic but also externally by comparison with other centers. Data collection and evaluation requires high-performance software that will be continuously improved, expanded, and adapted to current needs during regular meetings between the various users. (orig.) [de

  18. Developing model-making and model-breaking skills using direct measurement video-based activities

    Science.gov (United States)

    Vonk, Matthew; Bohacek, Peter; Militello, Cheryl; Iverson, Ellen

    2017-12-01

    This study focuses on student development of two important laboratory skills in the context of introductory college-level physics. The first skill, which we call model making, is the ability to analyze a phenomenon in a way that produces a quantitative multimodal model. The second skill, which we call model breaking, is the ability to critically evaluate if the behavior of a system is consistent with a given model. This study involved 116 introductory physics students in four different sections, each taught by a different instructor. All of the students within a given class section participated in the same instruction (including labs) with the exception of five activities performed throughout the semester. For those five activities, each class section was split into two groups; one group was scaffolded to focus on model-making skills and the other was scaffolded to focus on model-breaking skills. Both conditions involved direct measurement videos. In some cases, students could vary important experimental parameters within the video like mass, frequency, and tension. Data collected at the end of the semester indicate that students in the model-making treatment group significantly outperformed the other group on the model-making skill despite the fact that both groups shared a common physical lab experience. Likewise, the model-breaking treatment group significantly outperformed the other group on the model-breaking skill. This is important because it shows that direct measurement video-based instruction can help students acquire science-process skills, which are critical for scientists, and which are a key part of current science education approaches such as the Next Generation Science Standards and the Advanced Placement Physics 1 course.

  19. Quality assurance in field radiation measurements

    International Nuclear Information System (INIS)

    Howell, W.P.

    1985-01-01

    In most cases, an ion chamber radiation measuring instrument is calibrated in a uniform gamma radiation field. This results in a uniform ionization field throughout the ion chamber. Measurement conditions encountered in the field often produce non-uniform ionization fields within the ion chamber, making determination of true dose rates to personnel difficult and prone to error. Extensive studies performed at Hanford have provided appropriate correction factors for use with one type of ion chamber instrument, the CP. Suitable corrections are available for the following distinct measurement circumstances: (1) contact measurements on large beta and gamma sources, (2) contact measurements on small beta and gamma sources, (3) contact measurements on small-diameter cylinders, (4) measurements in small gamma beams, and (5) measurements at a distance from large beta sources. Recommendations are made for the implementation of these correction factors, in the interest of improved quality assurance in field radiation measurements. 12 references, 10 figures

  20. Enhancing Perceived Quality of Compressed Images and Video with Anisotropic Diffusion and Fuzzy Filtering

    DEFF Research Database (Denmark)

    Nadernejad, Ehsan; Korhonen, Jari; Forchhammer, Søren

    2013-01-01

    and subjective results on JPEG compressed images, as well as MJPEG and H.264/AVC compressed video, indicate that the proposed algorithms employing directional and spatial fuzzy filters achieve better artifact reduction than other methods. In particular, robust improvements with H.264/AVC video have been gained...

  1. Resolution enhancement of low quality videos using a high-resolution frame

    NARCIS (Netherlands)

    Pham, T.Q.; Van Vliet, L.J.; Schutte, K.

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of

  2. Quality Management of Measurements incl. Documentation

    DEFF Research Database (Denmark)

    Tosello, Guido; De Chiffre, Leonardo

    2004-01-01

    -Nürnberg, Chair for Quality Management and Manufacturing-Oriented Metrology (Germany). 'Metro-E-Learn' project proposes to develop and implement a coherent learning and competence chain that leads from introductory and foundation e-courses in initial manufacturing engineering studies towards higher....... Machine tool testing 9. The role of manufacturing metrology for QM 10. Inspection planning 11. Quality management of measurements incl. Documentation 12. Advanced manufacturing measurement technology The present report (which represents the section 11 - Quality management of measurements incl....... Documentation – of the e-learning system) is part of the contribution of the Department for Manufacturing Engineering and Management (IPL) / Centre for Geometrical Metrology (CGM) at the Technical University of Denmark to the MINERVA EU project mentioned above....

  3. Measures of Quality in Business Process Modelling

    Directory of Open Access Journals (Sweden)

    Radek Hronza

    2015-06-01

    Full Text Available Business process modelling and analysing is undoubtedly one of the most important parts of Applied (Business Informatics. Quality of business process models (diagrams is crucial for any purpose in this area. The goal of a process analyst’s work is to create generally understandable, explicit and error free models. If a process is properly described, created models can be used as an input into deep analysis and optimization. It can be assumed that properly designed business process models (similarly as in the case of correctly written algorithms contain characteristics that can be mathematically described. Besides it will be possible to create a tool that will help process analysts to design proper models. As part of this review will be conducted systematic literature review in order to find and analyse business process model’s design and business process model’s quality measures. It was found that mentioned area had already been the subject of research investigation in the past. Thirty-three suitable scietific publications and twenty-two quality measures were found. Analysed scientific publications and existing quality measures do not reflect all important attributes of business process model’s clarity, simplicity and completeness. Therefore it would be appropriate to add new measures of quality.

  4. Measuring fish and their physical habitats: Versatile 2D and 3D video techniques with user-friendly software

    Science.gov (United States)

    Neuswanger, Jason R.; Wipfli, Mark S.; Rosenberger, Amanda E.; Hughes, Nicholas F.

    2017-01-01

    Applications of video in fisheries research range from simple biodiversity surveys to three-dimensional (3D) measurement of complex swimming, schooling, feeding, and territorial behaviors. However, researchers lack a transparently developed, easy-to-use, general purpose tool for 3D video measurement and event logging. Thus, we developed a new measurement system, with freely available, user-friendly software, easily obtained hardware, and flexible underlying mathematical methods capable of high precision and accuracy. The software, VidSync, allows users to efficiently record, organize, and navigate complex 2D or 3D measurements of fish and their physical habitats. Laboratory tests showed submillimetre accuracy in length measurements of 50.8 mm targets at close range, with increasing errors (mostly competitors, out to a distance of 1.0 to 2.9 body lengths. This system makes 3D video measurement a practical tool for laboratory and field studies of aquatic or terrestrial animal behavior and ecology.

  5. Dynamic Video Streaming in Caching-enabled Wireless Mobile Networks

    OpenAIRE

    Liang, C.; Hu, S.

    2017-01-01

    Recent advances in software-defined mobile networks (SDMNs), in-network caching, and mobile edge computing (MEC) can have great effects on video services in next generation mobile networks. In this paper, we jointly consider SDMNs, in-network caching, and MEC to enhance the video service in next generation mobile networks. With the objective of maximizing the mean measurement of video quality, an optimization problem is formulated. Due to the coupling of video data rate, computing resource, a...

  6. Neurosurgical Skills Assessment: Measuring Technical Proficiency in Neurosurgery Residents Through Intraoperative Video Evaluations.

    Science.gov (United States)

    Sarkiss, Christopher A; Philemond, Steven; Lee, James; Sobotka, Stanislaw; Holloway, Terrell D; Moore, Maximillian M; Costa, Anthony B; Gordon, Errol L; Bederson, Joshua B

    2016-05-01

    Although technical skills are fundamental in neurosurgery, there is little agreement on how to describe, measure, or compare skills among surgeons. The primary goal of this study was to develop a quantitative grading scale for technical surgical performance that distinguishes operator skill when graded by domain experts (residents, attendings, and nonsurgeons). Scores provided by raters should be highly reliable with respect to scores from other observers. Neurosurgery residents were fitted with a head-mounted video camera while performing craniotomies under attending supervision. Seven videos, 1 from each postgraduate year (PGY) level (1-7), were anonymized and scored by 16 attendings, 8 residents, and 7 nonsurgeons using a grading scale. Seven skills were graded: incision, efficiency of instrument use, cauterization, tissue handling, drilling/craniotomy, confidence, and training level. A strong correlation was found between skills score and PGY year (P Technical skills of neurosurgery residents recorded during craniotomy can be measured with high interrater reliability. Surgeons and nonsurgeons alike readily distinguish different skill levels. This type of assessment could be used to coach residents, to track performance over time, and potentially to compare skill levels. Developing an objective tool to evaluate surgical performance would be useful in several areas of neurosurgery education. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Understanding the role of social context and user factors in video quality of experience

    NARCIS (Netherlands)

    Zhu, Y.; Heynderickx, I.E.J.; Redi, J.A.

    2015-01-01

    Quality of Experience is a concept to reflect the level of satisfaction of a user with a multimedia content, service or system. So far, the objective (i.e., computational) approaches to measure QoE have been mostly based on the analysis of the media technical properties. However, recent studies have

  8. Quality measures in applications of image restoration.

    Science.gov (United States)

    Kriete, A; Naim, M; Schafer, L

    2001-01-01

    We describe a new method for the estimation of image quality in image restoration applications. We demonstrate this technique on a simulated data set of fluorescent beads, in comparison with restoration by three different deconvolution methods. Both the number of iterations and a regularisation factor are varied to enforce changes in the resulting image quality. First, the data sets are directly compared by an accuracy measure. These values serve to validate the image quality descriptor, which is developed on the basis of optical information theory. This most general measure takes into account the spectral energies and the noise, weighted in a logarithmic fashion. It is demonstrated that this method is particularly helpful as a user-oriented method to control the output of iterative image restorations and to eliminate the guesswork in choosing a suitable number of iterations.

  9. Imagining life with an ostomy: Does a video intervention improve quality-of-life predictions for a medical condition that may elicit disgust?☆

    Science.gov (United States)

    Angott, Andrea M.; Comerford, David A.; Ubel, Peter A.

    2014-01-01

    Objective To test a video intervention as a way to improve predictions of mood and quality-of-life with an emotionally evocative medical condition. Such predictions are typically inaccurate, which can be consequential for decision making. Method In Part 1, people presently or formerly living with ostomies predicted how watching a video depicting a person changing his ostomy pouch would affect mood and quality-of-life forecasts for life with an ostomy. In Part 2, participants from the general public read a description about life with an ostomy; half also watched a video depicting a person changing his ostomy pouch. Participants’ quality-of-life and mood forecasts for life with an ostomy were assessed. Results Contrary to our expectations, and the expectations of people presently or formerly living with ostomies, the video did not reduce mood or quality-of-life estimates, even among participants high in trait disgust sensitivity. Among low-disgust participants, watching the video increased quality-of-life predictions for ostomy. Conclusion Video interventions may improve mood and quality-of-life forecasts for medical conditions, including those that may elicit disgust, such as ostomy. Practice implications Video interventions focusing on patients’ experience of illness continue to show promise as components of decision aids, even for emotionally charged health states such as ostomy. PMID:23177398

  10. Air quality measurements for site characterization

    International Nuclear Information System (INIS)

    Carter, M.W.; Conklin, W.C.

    1982-01-01

    Effective and timely site characterization is an important part of selecting a site for low-level waste disposal. Parameters measured can be compared with pertinent regulatory requirements, used for a reference base, helpful in evaluating environmental impacts, utilized in documenting changes in control programs, of value in modeling studies and other data uses, and beneficial in providing relevant sampling and methodology training. This paper will focus on specific air quality measurements which should be an inherent part of the site characterization program. The program is designed to measure, quantify, and identify contributions from site uses (operational procedures), atmospheric fallout, natural radioactivity, and vicinity and regional applications of radionuclides. The recommended air quality measurements program will be described in association with a reference site developd by the US Nuclear Regulatory Commission. Particular attention will be devoted to the type and quality of information which is needed, the scope of sampling and measurements, the frequency of measurements, locations and numbers of sampling stations, the period of time needed for site characterization, and the proper uses of the information once it has been obtained. Adequate characterization of the site will be most important in final site selection and in the operation of the site as to periodically assessing environmental impacts and helping guide any remedial control efforts designed to meet regulatory requirements

  11. A high precision video-electronic measuring system for use with solid state track detectors

    International Nuclear Information System (INIS)

    Schott, J.U.; Schopper, E.; Staudte, R.

    1976-01-01

    A video-electronic image analyzing system Quantimet 720 has been modified to meet the requirements of the measurement of tracks of nuclear particles in solid state track detectors with resulting improvement of precision, speed, and the elimination of subjective influences. A microscope equipped with an automatic XY stage projects the image onto the cathode of a vidicon-amplifier. Within the TV-picture generated, characterized by the coordinate XY in the specimen, we determine coordinates xy of events by setting cross lines on the screen which correspond to a digital accuracy of 0.1 μm at the position of the object. Automatic movement in Z-direction can be performed by stepping motor and measured electronically, or continously by setting electric voltage on a piezostrictive support of the objective. (orig.) [de

  12. Fractal measures of video-recorded trajectories can classify motor subtypes in Parkinson's Disease

    Science.gov (United States)

    Figueiredo, Thiago C.; Vivas, Jamile; Peña, Norberto; Miranda, José G. V.

    2016-11-01

    Parkinson's Disease is one of the most prevalent neurodegenerative diseases in the world and affects millions of individuals worldwide. The clinical criteria for classification of motor subtypes in Parkinson's Disease are subjective and may be misleading when symptoms are not clearly identifiable. A video recording protocol was used to measure hand tremor of 14 individuals with Parkinson's Disease and 7 healthy subjects. A method for motor subtype classification was proposed based on the spectral distribution of the movement and compared with the existing clinical criteria. Box-counting dimension and Hurst Exponent calculated from the trajectories were used as the relevant measures for the statistical tests. The classification based on the power-spectrum is shown to be well suited to separate patients with and without tremor from healthy subjects and could provide clinicians with a tool to aid in the diagnosis of patients in an early stage of the disease.

  13. Rheumatoid Arthritis Educational Video Series

    Science.gov (United States)

    ... Corner / Patient Webcasts / Rheumatoid Arthritis Educational Video Series Rheumatoid Arthritis Educational Video Series This series of five videos ... Your Arthritis Managing Chronic Pain and Depression in Arthritis Nutrition & Rheumatoid Arthritis Arthritis and Health-related Quality of Life ...

  14. Many quality measurements, but few quality measures assessing the quality of breast cancer care in women: A systematic review

    Directory of Open Access Journals (Sweden)

    Zhang Li

    2006-12-01

    Full Text Available Abstract Background Breast cancer in women is increasingly frequent, and care is complex, onerous and expensive, all of which lend urgency to improvements in care. Quality measurement is essential to monitor effectiveness and to guide improvements in healthcare. Methods Ten databases, including Medline, were searched electronically to identify measures assessing the quality of breast cancer care in women (diagnosis, treatment, followup, documentation of care. Eligible studies measured adherence to standards of breast cancer care in women diagnosed with, or in treatment for, any histological type of adenocarcinoma of the breast. Reference lists of studies, review articles, web sites, and files of experts were searched manually. Evidence appraisal entailed dual independent assessments of data (e.g., indicators used in quality measurement. The extent of each quality indicator's scientific validation as a measure was assessed. The American Society of Clinical Oncology (ASCO was asked to contribute quality measures under development. Results Sixty relevant reports identified 58 studies with 143 indicators assessing adherence to quality breast cancer care. A paucity of validated indicators (n = 12, most of which assessed quality of life, only permitted a qualitative data synthesis. Most quality indicators evaluated processes of care. Conclusion While some studies revealed patterns of under-use of care, all adherence data require confirmation using validated quality measures. ASCO's current development of a set of quality measures relating to breast cancer care may hold the key to conducting definitive studies.

  15. Many quality measurements, but few quality measures assessing the quality of breast cancer care in women: a systematic review.

    Science.gov (United States)

    Schachter, Howard M; Mamaladze, Vasil; Lewin, Gabriela; Graham, Ian D; Brouwers, Melissa; Sampson, Margaret; Morrison, Andra; Zhang, Li; O'Blenis, Peter; Garritty, Chantelle

    2006-12-18

    Breast cancer in women is increasingly frequent, and care is complex, onerous and expensive, all of which lend urgency to improvements in care. Quality measurement is essential to monitor effectiveness and to guide improvements in healthcare. Ten databases, including Medline, were searched electronically to identify measures assessing the quality of breast cancer care in women (diagnosis, treatment, followup, documentation of care). Eligible studies measured adherence to standards of breast cancer care in women diagnosed with, or in treatment for, any histological type of adenocarcinoma of the breast. Reference lists of studies, review articles, web sites, and files of experts were searched manually. Evidence appraisal entailed dual independent assessments of data (e.g., indicators used in quality measurement). The extent of each quality indicator's scientific validation as a measure was assessed. The American Society of Clinical Oncology (ASCO) was asked to contribute quality measures under development. Sixty relevant reports identified 58 studies with 143 indicators assessing adherence to quality breast cancer care. A paucity of validated indicators (n = 12), most of which assessed quality of life, only permitted a qualitative data synthesis. Most quality indicators evaluated processes of care. While some studies revealed patterns of under-use of care, all adherence data require confirmation using validated quality measures. ASCO's current development of a set of quality measures relating to breast cancer care may hold the key to conducting definitive studies.

  16. 3D video-based deformation measurement of the pelvis bone under dynamic cyclic loading

    Directory of Open Access Journals (Sweden)

    Freslier Marie

    2011-07-01

    Full Text Available Abstract Background Dynamic three-dimensional (3D deformation of the pelvic bones is a crucial factor in the successful design and longevity of complex orthopaedic oncological implants. The current solutions are often not very promising for the patient; thus it would be interesting to measure the dynamic 3D-deformation of the whole pelvic bone in order to get a more realistic dataset for a better implant design. Therefore we hypothesis if it would be possible to combine a material testing machine with a 3D video motion capturing system, used in clinical gait analysis, to measure the sub millimetre deformation of a whole pelvis specimen. Method A pelvis specimen was placed in a standing position on a material testing machine. Passive reflective markers, traceable by the 3D video motion capturing system, were fixed to the bony surface of the pelvis specimen. While applying a dynamic sinusoidal load the 3D-movement of the markers was recorded by the cameras and afterwards the 3D-deformation of the pelvis specimen was computed. The accuracy of the 3D-movement of the markers was verified with 3D-displacement curve with a step function using a manual driven 3D micro-motion-stage. Results The resulting accuracy of the measurement system depended on the number of cameras tracking a marker. The noise level for a marker seen by two cameras was during the stationary phase of the calibration procedure ± 0.036 mm, and ± 0.022 mm if tracked by 6 cameras. The detectable 3D-movement performed by the 3D-micro-motion-stage was smaller than the noise level of the 3D-video motion capturing system. Therefore the limiting factor of the setup was the noise level, which resulted in a measurement accuracy for the dynamic test setup of ± 0.036 mm. Conclusion This 3D test setup opens new possibilities in dynamic testing of wide range materials, like anatomical specimens, biomaterials, and its combinations. The resulting 3D-deformation dataset can be used for a better

  17. Automated measurement of mouse social behaviors using depth sensing, video tracking, and machine learning.

    Science.gov (United States)

    Hong, Weizhe; Kennedy, Ann; Burgos-Artizzu, Xavier P; Zelikowsky, Moriel; Navonne, Santiago G; Perona, Pietro; Anderson, David J

    2015-09-22

    A lack of automated, quantitative, and accurate assessment of social behaviors in mammalian animal models has limited progress toward understanding mechanisms underlying social interactions and their disorders such as autism. Here we present a new integrated hardware and software system that combines video tracking, depth sensing, and machine learning for automatic detection and quantification of social behaviors involving close and dynamic interactions between two mice of different coat colors in their home cage. We designed a hardware setup that integrates traditional video cameras with a depth camera, developed computer vision tools to extract the body "pose" of individual animals in a social context, and used a supervised learning algorithm to classify several well-described social behaviors. We validated the robustness of the automated classifiers in various experimental settings and used them to examine how genetic background, such as that of Black and Tan Brachyury (BTBR) mice (a previously reported autism model), influences social behavior. Our integrated approach allows for rapid, automated measurement of social behaviors across diverse experimental designs and also affords the ability to develop new, objective behavioral metrics.

  18. Adaptive measurements of urban runoff quality

    Science.gov (United States)

    Wong, Brandon P.; Kerkez, Branko

    2016-11-01

    An approach to adaptively measure runoff water quality dynamics is introduced, focusing specifically on characterizing the timing and magnitude of urban pollutographs. Rather than relying on a static schedule or flow-weighted sampling, which can miss important water quality dynamics if parameterized inadequately, novel Internet-enabled sensor nodes are used to autonomously adapt their measurement frequency to real-time weather forecasts and hydrologic conditions. This dynamic approach has the potential to significantly improve the use of constrained experimental resources, such as automated grab samplers, which continue to provide a strong alternative to sampling water quality dynamics when in situ sensors are not available. Compared to conventional flow-weighted or time-weighted sampling schemes, which rely on preset thresholds, a major benefit of the approach is the ability to dynamically adapt to features of an underlying hydrologic signal. A 28 km2 urban watershed was studied to characterize concentrations of total suspended solids (TSS) and total phosphorus. Water quality samples were autonomously triggered in response to features in the underlying hydrograph and real-time weather forecasts. The study watershed did not exhibit a strong first flush and intraevent concentration variability was driven by flow acceleration, wherein the largest loadings of TSS and total phosphorus corresponded with the steepest rising limbs of the storm hydrograph. The scalability of the proposed method is discussed in the context of larger sensor network deployments, as well the potential to improving control of urban water quality.

  19. Measuring the Quality of Ecotourism Services

    Directory of Open Access Journals (Sweden)

    Nor’Aini Yusof

    2014-06-01

    Full Text Available Ecotourism forms the pillar of the country’s tourism industry. Ecotourists make up more than 10% of international tourists in Malaysia. When service quality is thought of as an important factor to the success of tourism service providers, the importance of estimating service quality provided to tourists becomes apparent. Estimating service quality provides tourism service providers with the necessary information needed to manage their marketing operations appropriately. Therefore, this estimation should be performed with the right measurement scales. Despite the high volume of research on service quality (SERVQUAL models in recent years, limited effort has been directed toward improving the tool for measuring service quality, particularly to apply to the ecotourism sector in developing countries. This article aims to improve a SERVQUAL model that is suitable for ecotourism areas in developing countries using five dimensions of the original model and one additional sustainability dimension. Based on a survey of 127 tourists in Tasik Kenyir, an exploratory factor analysis (EFA was conducted to discover the underlying dimension of ecotourism services and test for reliability and validity. Using EFA resulted in seven factors totaling 27 items. These factors are labeled as follows: tangible sustainability, sustainable practices, tangibility, reliability, responsiveness, assurance, and empathy. The results reveal that when SERVQUAL is applied within the ecotourism context, new dimensions of tangible sustainability and sustainable practices may emerge. The result implies the need to refine the SERVQUAL model when used in different contexts.

  20. In situ measurement of laser beam quality

    Science.gov (United States)

    Hashemi, Somayeh Sadat; Ghavami Sabouri, Saeed; Khorsandi, Alireza

    2017-09-01

    An innovative optical method is introduced for the beam quality measurement of any arbitrary transverse mode based on the reconstruction of the mode from a few-frame image of the beam cross-section. This is performed by the decomposition of a mode to its basic Hermite-Gaussian modal coefficients. The performance of the proposed method is examined through M 2-factor measurement of the beam of a Nd:YAG laser which was forced to oscillate in a certain mode using a crossed rectangular intracavity aperture. Obtained results have shown that this method can be alternatively replaced for the hologram- and ISO-based techniques recently exploiting for beam quality measurement regardless of the mode type and the position of utilized CCD camera along the beam direction.

  1. An Analysis of Quality of Service (QoS In Live Video Streaming Using Evolved HSPA Network Media

    Directory of Open Access Journals (Sweden)

    Achmad Zakaria Azhar

    2016-10-01

    Full Text Available Evolved High Speed Packet Access (HSPA+ is a mobile telecommunication system technology and the evolution of HSPA technology. This technology has a packet data based service with downlink speeds up to 21.1 Mbps and uplink speed up to 11.5 Mbps on the bandwidth 5MHz. This technology is expected to fulfill and support the needs for information that involves all aspects of multimedia such as video and audio, especially live video streaming. By utilizing this technology it will facilitate communicating the information, for example to monitoring the situation of the house, the news coverage at some certain area, and other events in real time. This thesis aims to identify and test the Quality of Service (QoS performance on the network that is used for live video streaming with the parameters of throughput, delay, jitter and packet loss. The software used for monitoring the data traffic of the live video streaming network is wireshark network analyzer. From the test results it is obtained that the average throughput of provider B is 5,295 Kbps bigger than the provider A, the average delay of provider B is 0.618 ms smaller than the provider A, the average jitter of provider B is 0.420 ms smaller than the provider A and the average packet loss of provider B is 0.451% smaller than the provider A.

  2. Video over cognitive radio networks when quality of service meets spectrum

    CERN Document Server

    Mao, Shiwen

    2014-01-01

    This book focuses on the problem of video streaming over emerging cognitive radio (CR) networks. The book discusses the problems and techniques for scalable video streaming over cellular cognitive radio networks, ad hoc CR networks, cooperative CR networks, and femtocell CR networks. The author formulates these problems and proposes optimal algorithms to solve these problems. Also, the book analyzes the proposed algorithms and validates the algorithms with simulations.

  3. Quality assurance in nuclear medicine radioactivity measurements

    International Nuclear Information System (INIS)

    Sahagia, Maria; Razdolescu Anamaria Cristina

    2007-01-01

    The paper presents some recent results of the Radionuclide Metrology Laboratory (RML) from IFIN-HH, in the assurance of quality in radioactivity measurements for nuclear medicine. Three aspects are treated: (i) Participation of the RML in the frame of the IAEA Coordinated Research Program (CRP), E 2.10.05; (ii) Improvement of the secondary standard, based on a CENTRONIC IG12/20A ionization chamber; (iii) Implementation of the quality management, according to the SR EN ISO/IEC 17025:2005. (authors)

  4. Quality improvement in neurology: dementia management quality measures.

    Science.gov (United States)

    Odenheimer, Germaine; Borson, Soo; Sanders, Amy E; Swain-Eng, Rebecca J; Kyomen, Helen H; Tierney, Samantha; Gitlin, Laura; Forciea, Mary Ann; Absher, John; Shega, Joseph; Johnson, Jerry

    2014-03-01

    Professional and advocacy organizations have long urged that dementia should be recognized and properly diagnosed. With the passage of the National Alzheimer's Project Act in 2011, an Advisory Council for Alzheimer's Research, Care, and Services was convened to advise the Department of Health and Human Services. In May 2012, the Council produced the first National Plan to address Alzheimer's disease, and prominent in its recommendations is a call for quality measures suitable for evaluating and tracking dementia care in clinical settings. Although other efforts have been made to set dementia care quality standards, such as those pioneered by RAND in its series Assessing Care of Vulnerable Elders (ACOVE), practitioners, healthcare systems, and insurers have not widely embraced implementation. This executive summary (full manuscript available at www.neurology.org) reports on a new measurement set for dementia management developed by an interdisciplinary Dementia Measures Work Group (DWG) representing the major national organizations and advocacy organizations concerned with the care of individuals with dementia. The American Academy of Neurology (AAN), the American Geriatrics Society, the American Medical Directors Association, the American Psychiatric Association, and the American Medical Association-convened Physician Consortium for Performance Improvement led this effort. The ACOVE measures and the measurement set described here apply to individuals whose dementia has already been identified and properly diagnosed. Although similar in concept to ACOVE, the DWG measurement set differs in several important ways; it includes all stages of dementia in a single measure set, calls for the use of functional staging in planning care, prompts the use of validated instruments in patient and caregiver assessment and intervention, highlights the relevance of using palliative care concepts to guide care before the advanced stages of illness, and provides evidence-based support

  5. Quality measurement by proportional counter with B

    International Nuclear Information System (INIS)

    Onizuka, Yoshihiko; Endo, Satoru; Tanaka, Kenichi

    2005-01-01

    The dosimetry of air and the tissue-equivalent phantom made of acryl are carried out by the tissue-equivalent proportional counter (TEPC) and TEPC with wall contained B, and both results were compared. The changes of quality with distance from the beam center are determined by the frequency mean renewal energy y F (y)and the dose mean renewal energy y D (y) as indicators of quality. Both y F (y)and y D (y) of tissue-equivalent phantom are larger than air, but very large change was not observed in all distance. The dose rate is determined by y D (y), the number of events and measurement time. Change of dose rate was larger than the change of quality. The maximum value of dose rate depended on γray and neutron beam showed at the point 2 cm away from the center. (S.Y.)

  6. Measuring physical neighborhood quality related to health.

    Science.gov (United States)

    Rollings, Kimberly A; Wells, Nancy M; Evans, Gary W

    2015-04-29

    Although sociodemographic factors are one aspect of understanding the effects of neighborhood environments on health, equating neighborhood quality with socioeconomic status ignores the important role of physical neighborhood attributes. Prior work on neighborhood environments and health has relied primarily on level of socioeconomic disadvantage as the indicator of neighborhood quality without attention to physical neighborhood quality. A small but increasing number of studies have assessed neighborhood physical characteristics. Findings generally indicate that there is an association between living in deprived neighborhoods and poor health outcomes, but rigorous evidence linking specific physical neighborhood attributes to particular health outcomes is lacking. This paper discusses the methodological challenges and limitations of measuring physical neighborhood environments relevant to health and concludes with proposed directions for future work.

  7. Perceptual quality estimation of H.264/AVC videos using reduced-reference and no-reference models

    Science.gov (United States)

    Shahid, Muhammad; Pandremmenou, Katerina; Kondi, Lisimachos P.; Rossholm, Andreas; Lövström, Benny

    2016-09-01

    Reduced-reference (RR) and no-reference (NR) models for video quality estimation, using features that account for the impact of coding artifacts, spatio-temporal complexity, and packet losses, are proposed. The purpose of this study is to analyze a number of potentially quality-relevant features in order to select the most suitable set of features for building the desired models. The proposed sets of features have not been used in the literature and some of the features are used for the first time in this study. The features are employed by the least absolute shrinkage and selection operator (LASSO), which selects only the most influential of them toward perceptual quality. For comparison, we apply feature selection in the complete feature sets and ridge regression on the reduced sets. The models are validated using a database of H.264/AVC encoded videos that were subjectively assessed for quality in an ITU-T compliant laboratory. We infer that just two features selected by RR LASSO and two bitstream-based features selected by NR LASSO are able to estimate perceptual quality with high accuracy, higher than that of ridge, which uses more features. The comparisons with competing works and two full-reference metrics also verify the superiority of our models.

  8. A review of techniques for the identification and measurement of fish in underwater stereo-video image sequences

    Science.gov (United States)

    Shortis, Mark R.; Ravanbakskh, Mehdi; Shaifat, Faisal; Harvey, Euan S.; Mian, Ajmal; Seager, James W.; Culverhouse, Philip F.; Cline, Danelle E.; Edgington, Duane R.

    2013-04-01

    Underwater stereo-video measurement systems are used widely for counting and measuring fish in aquaculture, fisheries and conservation management. To determine population counts, spatial or temporal frequencies, and age or weight distributions, snout to fork length measurements are captured from the video sequences, most commonly using a point and click process by a human operator. Current research aims to automate the measurement and counting task in order to improve the efficiency of the process and expand the use of stereo-video systems within marine science. A fully automated process will require the detection and identification of candidates for measurement, followed by the snout to fork length measurement, as well as the counting and tracking of fish. This paper presents a review of the techniques used for the detection, identification, measurement, counting and tracking of fish in underwater stereo-video image sequences, including consideration of the changing body shape. The review will analyse the most commonly used approaches, leading to an evaluation of the techniques most likely to be a general solution to the complete process of detection, identification, measurement, counting and tracking.

  9. Thermal image analysis of plastic deformation and fracture behavior by a thermo-video measurement system

    International Nuclear Information System (INIS)

    Ohbuchi, Yoshifumi; Sakamoto, Hidetoshi; Nagatomo, Nobuaki

    2016-01-01

    The visualization of the plastic region and the measurement of its size are necessary and indispensable to evaluate the deformation and fracture behavior of a material. In order to evaluate the plastic deformation and fracture behavior in a structural member with some flaws, the authors paid attention to the surface temperature which is generated by plastic strain energy. The visualization of the plastic deformation was developed by analyzing the relationship between the extension of the plastic deformation range and the surface temperature distribution, which was obtained by an infrared thermo-video system. Furthermore, FEM elasto-plastic analysis was carried out with the experiment, and the effectiveness of this non-contact measurement system of the plastic deformation and fracture process by a thermography system was discussed. The evaluation method using an infrared imaging device proposed in this research has a feature which does not exist in the current evaluation method, i.e. the heat distribution on the surface of the material has been measured widely by noncontact at 2D at high speed. The new measuring technique proposed here can measure the macroscopic plastic deformation distribution on the material surface widely and precisely as a 2D image, and at high speed, by calculation from the heat generation and the heat propagation distribution. (paper)

  10. MATIN: a random network coding based framework for high quality peer-to-peer live video streaming.

    Science.gov (United States)

    Barekatain, Behrang; Khezrimotlagh, Dariush; Aizaini Maarof, Mohd; Ghaeini, Hamid Reza; Salleh, Shaharuddin; Quintana, Alfonso Ariza; Akbari, Behzad; Cabrera, Alicia Triviño

    2013-01-01

    In recent years, Random Network Coding (RNC) has emerged as a promising solution for efficient Peer-to-Peer (P2P) video multicasting over the Internet. This probably refers to this fact that RNC noticeably increases the error resiliency and throughput of the network. However, high transmission overhead arising from sending large coefficients vector as header has been the most important challenge of the RNC. Moreover, due to employing the Gauss-Jordan elimination method, considerable computational complexity can be imposed on peers in decoding the encoded blocks and checking linear dependency among the coefficients vectors. In order to address these challenges, this study introduces MATIN which is a random network coding based framework for efficient P2P video streaming. The MATIN includes a novel coefficients matrix generation method so that there is no linear dependency in the generated coefficients matrix. Using the proposed framework, each peer encapsulates one instead of n coefficients entries into the generated encoded packet which results in very low transmission overhead. It is also possible to obtain the inverted coefficients matrix using a bit number of simple arithmetic operations. In this regard, peers sustain very low computational complexities. As a result, the MATIN permits random network coding to be more efficient in P2P video streaming systems. The results obtained from simulation using OMNET++ show that it substantially outperforms the RNC which uses the Gauss-Jordan elimination method by providing better video quality on peers in terms of the four important performance metrics including video distortion, dependency distortion, End-to-End delay and Initial Startup delay.

  11. MATIN: a random network coding based framework for high quality peer-to-peer live video streaming.

    Directory of Open Access Journals (Sweden)

    Behrang Barekatain

    Full Text Available In recent years, Random Network Coding (RNC has emerged as a promising solution for efficient Peer-to-Peer (P2P video multicasting over the Internet. This probably refers to this fact that RNC noticeably increases the error resiliency and throughput of the network. However, high transmission overhead arising from sending large coefficients vector as header has been the most important challenge of the RNC. Moreover, due to employing the Gauss-Jordan elimination method, considerable computational complexity can be imposed on peers in decoding the encoded blocks and checking linear dependency among the coefficients vectors. In order to address these challenges, this study introduces MATIN which is a random network coding based framework for efficient P2P video streaming. The MATIN includes a novel coefficients matrix generation method so that there is no linear dependency in the generated coefficients matrix. Using the proposed framework, each peer encapsulates one instead of n coefficients entries into the generated encoded packet which results in very low transmission overhead. It is also possible to obtain the inverted coefficients matrix using a bit number of simple arithmetic operations. In this regard, peers sustain very low computational complexities. As a result, the MATIN permits random network coding to be more efficient in P2P video streaming systems. The results obtained from simulation using OMNET++ show that it substantially outperforms the RNC which uses the Gauss-Jordan elimination method by providing better video quality on peers in terms of the four important performance metrics including video distortion, dependency distortion, End-to-End delay and Initial Startup delay.

  12. Accountability Quality Shuffler Measurements on Pits

    International Nuclear Information System (INIS)

    Rinard, P.M.

    2000-01-01

    Pits have generally been treated as accountable units that are intact if merely present and they are excluded from the more demanding nondestructive assay requirements. As pits begin to flow into disposition streams, there may be more incentive to measure the masses of their fissile components for accountability purposes. This Department of Energy Office of Safeguards and Security (OSS) Lifecycle Project has explored some ways in which such measurements may be done successfully. The active neutron instrument called a shuffler has been used to measure a variety of actual pits, and a calculational technique has been developed to accurately predict such count rates. Passive multiplicity counting has previously been applied to pits for determining their plutonium contents. This combination of measurement and calculational techniques provide powerful and accurate tools for determining the fissile contents of pits with the quality needed for accountability purposes

  13. Resolution enhancement of low-quality videos using a high-resolution frame

    Science.gov (United States)

    Pham, Tuan Q.; van Vliet, Lucas J.; Schutte, Klamer

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of corresponding LR-HR pairs of image patches from the HR still image, high-frequency details are transferred from the HR source to the LR video. The DCT-domain algorithm is much faster than example-based SR in spatial domain 6 because of a reduction in search dimensionality, which is a direct result of the compact and uncorrelated DCT representation. Fast searching techniques like tree-structure vector quantization 16 and coherence search1 are also key to the improved efficiency. Preliminary results on MJPEG sequence show promising result of the DCT-domain SR synthesis approach.

  14. Measurement quality assurance for radioassay laboratories

    International Nuclear Information System (INIS)

    McCurdy, D.E.

    1993-01-01

    Until recently, the quality of U.S. radioassay laboratory services has been evaluated by a limited number of governmental measurement assurance programs (MAPs). The major programs have been limited to the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA) and the U.S. Nuclear Regulatory Commission (NRC). In 1988, an industry MAP was established for the nuclear power utility industry through the U.S. Council for Energy Awareness/National Institute of Standards and Technology (USCEA/NIST). This program functions as both a MAP for utility laboratories and/or their commercial contractor laboratories, and as a traceability program for the U.S. radioactive source manufacturers and the utility laboratories. Each of these generic MAPs has been initiated and is maintained to serve the specific needs of the sponsoring agency or organization. As a result, there is diversification in their approach, scope, requirements, and degree of traceability to NIST. In 1987, a writing committee was formed under the American National Standards Institute (ANSI) N42.2 committee to develop a standard to serve as the basis document for the creation of a national measurement quality assurance (MQA) program for radioassay laboratories in the U.S. The standard is entitled, open-quotes Measurement Quality Assurance For Radioassay Laboratories.open-quotes The document was developed to serve as a guide for MQA programs maintained for the specialized sectors of the radioassay community, such as bioassay, routine environmental monitoring, environmental restoration and waste management, radiopharmaceuticals, and nuclear facilities. It was the intent of the writing committee to develop a guidance document that could be utilized to establish a laboratory's specific data quality objectives (DQOs) that govern the operational requirements of the radioassay process, including mandated protocols and recommendations

  15. Measurement quality assurance for radioassay laboratories

    Energy Technology Data Exchange (ETDEWEB)

    McCurdy, D.E. [Yankee Atomic Environmental Laboratory, Boston, MA (United States)

    1993-12-31

    Until recently, the quality of U.S. radioassay laboratory services has been evaluated by a limited number of governmental measurement assurance programs (MAPs). The major programs have been limited to the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA) and the U.S. Nuclear Regulatory Commission (NRC). In 1988, an industry MAP was established for the nuclear power utility industry through the U.S. Council for Energy Awareness/National Institute of Standards and Technology (USCEA/NIST). This program functions as both a MAP for utility laboratories and/or their commercial contractor laboratories, and as a traceability program for the U.S. radioactive source manufacturers and the utility laboratories. Each of these generic MAPs has been initiated and is maintained to serve the specific needs of the sponsoring agency or organization. As a result, there is diversification in their approach, scope, requirements, and degree of traceability to NIST. In 1987, a writing committee was formed under the American National Standards Institute (ANSI) N42.2 committee to develop a standard to serve as the basis document for the creation of a national measurement quality assurance (MQA) program for radioassay laboratories in the U.S. The standard is entitled, {open_quotes}Measurement Quality Assurance For Radioassay Laboratories.{open_quotes} The document was developed to serve as a guide for MQA programs maintained for the specialized sectors of the radioassay community, such as bioassay, routine environmental monitoring, environmental restoration and waste management, radiopharmaceuticals, and nuclear facilities. It was the intent of the writing committee to develop a guidance document that could be utilized to establish a laboratory`s specific data quality objectives (DQOs) that govern the operational requirements of the radioassay process, including mandated protocols and recommendations.

  16. Outcome measures and scar aesthetics in minimally invasive video-assisted parathyroidectomy.

    LENUS (Irish Health Repository)

    Casserly, Paula

    2012-02-01

    OBJECTIVES: To compare the scar outcome of video-assisted parathyroidectomy (VAP) with traditional bilateral cervical exploration (BCE) using previously validated scar assessment scales, and to examine the feasibility of introducing VAP into a general otolaryngology-head and neck practice. DESIGN: A retrospective review of medical records from a prospectively obtained database of patients and long-term follow-up of scar analysis. PATIENTS: The records of 60 patients undergoing parathyroidectomy were reviewed: 29 patients underwent VAP and 31 patients underwent an open procedure with BCE. The groups were matched for age and sex. A total of 46 patients were followed up to assess scar outcome. MAIN OUTCOME MEASURES: The primary outcome was a comparison of patient and observer scar satisfaction between VAP and traditional BCE using validated scar assessment tools: the Patient Scar Assessment Scale and the Manchester Scar Scale. The secondary outcomes were to retrospectively evaluate our results with VAP and to assess the suitability of introducing this technique into a general otolaryngology-head and neck practice. RESULTS: The average scar length in the VAP group was 1.7 cm, and the average scar length in the BCE group was 4.3 cm. The patients in the BCE group scored higher than the patients in the VAP group on the Manchester Scar Scale (P < .01) and on the Patient and Observer Scar Scales (P = .02), indicating a worse scar outcome. The mean operative time in the VAP group was 41 minutes compared with 115 minutes in the open procedure BCE group. There was no difference between the 2 groups in terms of postoperative complications. CONCLUSIONS: Video-assisted parathyroidectomy is a safe and feasible procedure in the setting of a general otolaryngology-head and neck practice, with outcomes and complication rates that are comparable to those of traditional bilateral neck exploration. Both patient and observer analysis demonstrated that VAP was associated with a more

  17. Measuring the quality of clinical audit projects.

    Science.gov (United States)

    Millard, A D

    2000-11-01

    The aim of the study was to develop and pilot a scale measuring the quality of audit projects through audit project reports. Statements about clinical audit projects were selected from existing instruments assessing the quality of clinical audit projects to form a Likert scale. Audit facilitators based in Scottish health boards and trusts piloted the scale. The participants were known to have over 2 years of experience of supporting clinical audit. The response at first test was 11 of 14 and at the second test 27 of 46. Audit facilitators tested the draft scale by expressing their strength of agreement or disagreement with each statement for three reports. Validity and reliability were assessed by test - re-test, item - total, and total - global indicator correlation. Of the 20 statements, 15 had satisfactory correlation with scale totals. Scale totals had good correlation with global indicators. Test re-test correlation was modest. The wide range of responses means further research is needed to measure the consistency of audit facilitators' interpretations, perhaps comparing a trained group with an untrained group. There may be a need for a separate scale for reaudits. Educational impact is distinct from project impact generally. It may be more meaningful to treat the selection of projects and aims, methodology and impact separately as subscales and take a project profiling approach rather than attempting to produce a global quality index.

  18. Video imaging measurement of interfacial wave velocity in air-water flow through a horizontal elbow

    Science.gov (United States)

    Al-Wazzan, Amir; Than, Cheok F.; Moghavvemi, Mahmoud; Yew, Chia W.

    2001-10-01

    Two-phase flow in pipelines containing elbows represents a common situation in the oil and gas industries. This study deals with the stratified flow regime between the gas and liquid phase through an elbow. It is of interest to study the change in wave characteristics by measuring the wave velocity and wavelength at the inlet and outlet of the elbow. The experiments were performed under concurrent air-water stratified flow in a horizontal transparent polycarbonate pipe of 0.05m diameter and superficial air and water velocities up to 8.97 and 0.0778 m/s respectively. A non-intrusive video imaging technique was applied to capture the waves. For image analysis, a frame by frame direct overlapping method was used to detect for pulsating flow and a pixel shifting method based on the detection of minimum values in the overlap function was used to determine wave velocity and wavelength. Under superficial gas velocity of less than 4.44 m/s, the results suggest a regular pulsating outflow produced by the elbow. At higher gas velocities, more random pulsation was found and the emergence of localized interfacial waves was detected. Wave velocities measured by this technique were found to produce satisfactory agreement with direct measurements.

  19. Real-time measurement of dust in the workplace using video exposure monitoring: Farming to pharmaceuticals

    International Nuclear Information System (INIS)

    Walsh, P T; Forth, A R; Clark, R D R; Dowker, K P; Thorpe, A

    2009-01-01

    Real-time, photometric, portable dust monitors have been employed for video exposure monitoring (VEM) to measure and highlight dust levels generated by work activities, illustrate dust control techniques, and demonstrate good practice. Two workplaces, presenting different challenges for measurement, were used to illustrate the capabilities of VEM: (a) poultry farming activities and (b) powder transfer operations in a pharmaceutical company. For the poultry farm work, the real-time monitors were calibrated with respect to the respirable and inhalable dust concentrations using cyclone and IOM reference samplers respectively. Different rankings of exposure for typical activities were found on the small farm studied here compared to previous exposure measurements at larger poultry farms: these were mainly attributed to the different scales of operation. Large variations in the ratios of respirable, inhalable and real-time monitor TWA concentrations of poultry farm dust for various activities were found. This has implications for the calibration of light-scattering dust monitors with respect to inhalable dust concentration. In the pharmaceutical application, the effectiveness of a curtain barrier for dust control when dispensing powder in a downflow booth was rapidly demonstrated.

  20. Measuring Cognitive Load in the Presence of Educational Video: Towards a Multimodal Methodology

    Science.gov (United States)

    Kruger, Jan-Louis; Doherty, Stephen

    2016-01-01

    The use of video has become well established in education, from traditional courses to blended and online courses. It has grown both in its diversity of applications as well as its content. Such educational video however is not fully accessible to all students, particularly those who require additional visual support or students studying in a…

  1. The effect of video review of resident laparoscopic surgical skills measured by self- and external assessment.

    Science.gov (United States)

    Herrera-Almario, Gabriel E; Kirk, Katherine; Guerrero, Veronica T; Jeong, Kwonho; Kim, Sara; Hamad, Giselle G

    2016-02-01

    Video review of surgical skills is an educational modality that allows trainees to reflect on self-performance. The purpose of this study was to determine whether resident and attending assessments of a resident's laparoscopic performance differ and whether video review changes assessments. Third-year surgery residents were invited to participate. Elective laparoscopic procedures were video recorded. The Global Operative Assessment of Laparoscopic Skills evaluation was completed immediately after the procedure and again 7 to 10 days later by both resident and attending. Scores were compared using t tests. Nine residents participated and 76 video reviews were completed. Residents scored themselves significantly lower than the faculty scores both before and after video review. Resident scores did not change significantly after video review. Attending and resident self-assessment of laparoscopic skills differs and subsequent video review does not significantly affect Global Operative Assessment of Laparoscopic Skills scores. Further studies should evaluate the impact of video review combined with verbal feedback on skill acquisition and assessment. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Defining Multiple Chronic Conditions for Quality Measurement.

    Science.gov (United States)

    Drye, Elizabeth E; Altaf, Faseeha K; Lipska, Kasia J; Spatz, Erica S; Montague, Julia A; Bao, Haikun; Parzynski, Craig S; Ross, Joseph S; Bernheim, Susannah M; Krumholz, Harlan M; Lin, Zhenqiu

    2018-02-01

    Patients with multiple chronic conditions (MCCs) are a critical but undefined group for quality measurement. We present a generally applicable systematic approach to defining an MCC cohort of Medicare fee-for-service beneficiaries that we developed for a national quality measure, risk-standardized rates of unplanned admissions for Accountable Care Organizations. To define the MCC cohort we: (1) identified potential chronic conditions; (2) set criteria for cohort conditions based on MCC framework and measure concept; (3) applied the criteria informed by empirical analysis, experts, and the public; (4) described "broader" and "narrower" cohorts; and (5) selected final cohort with stakeholder input. Subjects were patients with chronic conditions. Participants included 21.8 million Medicare fee-for-service beneficiaries in 2012 aged 65 years and above with ≥1 of 27 Medicare Chronic Condition Warehouse condition(s). In total, 10 chronic conditions were identified based on our criteria; 8 of these 10 were associated with notably increased admission risk when co-occurring. A broader cohort (2+ of the 8 conditions) included 4.9 million beneficiaries (23% of total cohort) with an admission rate of 70 per 100 person-years. It captured 53% of total admissions. The narrower cohort (3+ conditions) had 2.2 million beneficiaries (10%) with 100 admissions per 100 person-years and captured 32% of admissions. Most stakeholders viewed the broader cohort as best aligned with the measure concept. By systematically narrowing chronic conditions to those most relevant to the outcome and incorporating stakeholder input, we defined an MCC admission measure cohort supported by stakeholders. This approach can be used as a model for other MCC outcome measures.

  3. Delivering stable high-quality video: an SDN architecture with DASH assisting network elements

    NARCIS (Netherlands)

    J.W.M. Kleinrouweler (Jan Willem); S. Cabrero Barros (Sergio); P.S. Cesar Garcia (Pablo Santiago)

    2016-01-01

    textabstractDynamic adaptive streaming over HTTP (DASH) is a simple, but effective, technology for video streaming over the Internet. It provides adaptive streaming while being highly scalable at the side of the content providers. However, the mismatch between TCP and the adaptive bursty nature of

  4. Dependency of human target detection performance on clutter and quality of supporting image analysis algorithms in a video surveillance task

    Science.gov (United States)

    Huber, Samuel; Dunau, Patrick; Wellig, Peter; Stein, Karin

    2017-10-01

    Background: In target detection, the success rates depend strongly on human observer performances. Two prior studies tested the contributions of target detection algorithms and prior training sessions. The aim of this Swiss-German cooperation study was to evaluate the dependency of human observer performance on the quality of supporting image analysis algorithms. Methods: The participants were presented 15 different video sequences. Their task was to detect all targets in the shortest possible time. Each video sequence showed a heavily cluttered simulated public area from a different viewing angle. In each video sequence, the number of avatars in the area was altered to 100, 150 and 200 subjects. The number of targets appearing was kept at 10%. The number of marked targets varied from 0, 5, 10, 20 up to 40 marked subjects while keeping the positive predictive value of the detection algorithm at 20%. During the task, workload level was assessed by applying an acoustic secondary task. Detection rates and detection times for the targets were analyzed using inferential statistics. Results: The study found Target Detection Time to increase and Target Detection Rates to decrease with increasing numbers of avatars. The same is true for the Secondary Task Reaction Time while there was no effect on Secondary Task Hit Rate. Furthermore, we found a trend for a u-shaped correlation between the numbers of markings and RTST indicating increased workload. Conclusion: The trial results may indicate useful criteria for the design of training and support of observers in observational tasks.

  5. Behind the NAT??? A measurement based evaluation of cellular service quality

    DEFF Research Database (Denmark)

    Kaup, F.; Michelinakis, F.; Bui, N.

    2015-01-01

    Mobile applications such as VoIP, (live) gaming, or video streaming have diverse QoS requirements ranging from low delay to high throughput. The optimization of the network quality experienced by end-users requires detailed knowledge of the expected network performance. Also, the achieved service...... quality is affected by a number of factors, including network operator and available technologies. However, most studies focusing on measuring the cellular network do not consider the performance implications of network configuration and management. To this end, this paper reports about an extensive data...

  6. A customizable open-source framework for measuring and equalizing e2e delays in shared video watching

    NARCIS (Netherlands)

    M.A. Montagud Climent (Mario); F. Boronat (Fernando); P.S. Cesar Garcia (Pablo Santiago)

    2014-01-01

    htmlabstractLow-latency and media sync are essential requirements to enable interactive multi-party services, such as Social TV. In this work, we present an open-source and customizable framework that allows measuring end-to-end (e2e) video delays and provides support for different types of media

  7. A discriminative structural similarity measure and its application to video-volume registration for endoscope three-dimensional motion tracking.

    Science.gov (United States)

    Luo, Xiongbiao; Mori, Kensaku

    2014-06-01

    Endoscope 3-D motion tracking, which seeks to synchronize pre- and intra-operative images in endoscopic interventions, is usually performed as video-volume registration that optimizes the similarity between endoscopic video and pre-operative images. The tracking performance, in turn, depends significantly on whether a similarity measure can successfully characterize the difference between video sequences and volume rendering images driven by pre-operative images. The paper proposes a discriminative structural similarity measure, which uses the degradation of structural information and takes image correlation or structure, luminance, and contrast into consideration, to boost video-volume registration. By applying the proposed similarity measure to endoscope tracking, it was demonstrated to be more accurate and robust than several available similarity measures, e.g., local normalized cross correlation, normalized mutual information, modified mean square error, or normalized sum squared difference. Based on clinical data evaluation, the tracking error was reduced significantly from at least 14.6 mm to 4.5 mm. The processing time was accelerated more than 30 frames per second using graphics processing unit.

  8. Light-reflection random-target method for measurement of the modulation transfer function of a digital video-camera

    Czech Academy of Sciences Publication Activity Database

    Pospíšil, Jaroslav; Jakubík, P.; Machala, L.

    2005-01-01

    Roč. 116, - (2005), s. 573-585 ISSN 0030-4026 Institutional research plan: CEZ:AV0Z10100522 Keywords : random-target measuring method * light-reflection white - noise target * digital video camera * modulation transfer function * power spectral density Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.395, year: 2005

  9. Quality assurance for radon measurements in Germany

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Foerster, E.; Schmidt, V.

    2005-01-01

    Full text: Radiation protection regarding work activities at workplaces with naturally occurring radiation has been regulated in the German Radiation Protection Ordinance. Regulations refer only to workplaces where the presence of natural radiation leads to a significant increase in the exposure of workers. These workplaces were identified in the following working areas with enhanced exposures to radon-222: underground mines, including visitor mines and show caves; radon-spas and galleries; water supply and distribution industries. Presently, regulations are being initiated by the German government to limit the exposures to radon in homes. For radon measurements at workplaces passive radon devices for individual monitoring as well as active measuring systems for workplace monitoring can be used. However, passive radon devices are preferred for radon measurements in homes because of low costs and availability in large quantities. To assure the quality of radon measurements the German Federal Office for Radiation Protection (BfS) has established annual interlaboratory comparisons for passive radon devices. The comparisons are carried out in the BfS radon calibration laboratory accredited by the German Calibration Service. Passive radon devices which use solid state track detectors, electrets or activated charcoal can be submitted. Approved radon services which offer radon measurements to determine radon exposure in homes and at workplaces have to pass the comparisons successfully. (author)

  10. Quality management for discharge measurements in Bavaria

    Energy Technology Data Exchange (ETDEWEB)

    Roth, Carmen [Hydrology of surface Waters, Bavarian Environment Agency, Hof (Germany)], E-mail: Carmen.Roth@lfu.bayern.de

    2008-11-01

    The hydrology of surface waters is based on the knowledge of the two main hydrological parameters, water level and discharge. These data are not only needed for almost every hydrological planning, but are very important for the management of high and low water. Our long term goal is a complete registration of every natural runoff - covering everything from low to high water - at our 600 measuring stations using limited resources but at the same time achieving high reliability and quality. To this point we are currently enforcing the use of modern data acquisition technology for water level and discharge measurements. The new techniques enable a continuous registration of water levels, actual velocity and consequently the discharge. Currently we are using gauging methods like the well known bubble gauge and radar, while the ultrasonic systems become more and more frequent. The moving boat techniques using the ultrasonic-Doppler-systems (e.g. ADCP, Q-Liner) are gradually substituting traditional methods for discharge measurement. In addition to that hydraulic methods (e. g. SIMK (registered) ) are being incorporated in the measuring systems as well. Since 2000 almost all gauges have been equipped with data loggers and automatic data transmission systems. One of the outcomes of these investments is the online availability of hydrological data on our website (www.hnd.bayern.de) where high quality data can be easily accessed. A new project has been initiated to improve the present rating curve. By means of hydraulic calculation the curve will be verified and if necessary adjusted to minimise deviations in the near future, which is of high importance especially for flooding forecasts.

  11. Quality management for discharge measurements in Bavaria

    International Nuclear Information System (INIS)

    Roth, Carmen

    2008-01-01

    The hydrology of surface waters is based on the knowledge of the two main hydrological parameters, water level and discharge. These data are not only needed for almost every hydrological planning, but are very important for the management of high and low water. Our long term goal is a complete registration of every natural runoff - covering everything from low to high water - at our 600 measuring stations using limited resources but at the same time achieving high reliability and quality. To this point we are currently enforcing the use of modern data acquisition technology for water level and discharge measurements. The new techniques enable a continuous registration of water levels, actual velocity and consequently the discharge. Currently we are using gauging methods like the well known bubble gauge and radar, while the ultrasonic systems become more and more frequent. The moving boat techniques using the ultrasonic-Doppler-systems (e.g. ADCP, Q-Liner) are gradually substituting traditional methods for discharge measurement. In addition to that hydraulic methods (e. g. SIMK (registered) ) are being incorporated in the measuring systems as well. Since 2000 almost all gauges have been equipped with data loggers and automatic data transmission systems. One of the outcomes of these investments is the online availability of hydrological data on our website (www.hnd.bayern.de) where high quality data can be easily accessed. A new project has been initiated to improve the present rating curve. By means of hydraulic calculation the curve will be verified and if necessary adjusted to minimise deviations in the near future, which is of high importance especially for flooding forecasts.

  12. Measures of Image Quality. Chapter 4

    Energy Technology Data Exchange (ETDEWEB)

    Maidment, A. D.A. [University of Pennsylvania, Philadelphia (United States)

    2014-09-15

    A medical image is a pictorial representation of a measurement of an object or function of the body. This information can be acquired in one to three spatial dimensions. It can be static or dynamic, meaning that it can also be measured as a function of time. Certain fundamental properties can be associated with all of these data. Firstly, no image can exactly represent the object or function; at best, one has a measurement with an associated error equal to the difference between the true object and the measured image. Secondly, no two images will be identical, even if acquired with the same imaging system of the same anatomic region; this variability is generally referred to as noise. There are many different ways to acquire medical image data; the various mechanisms of acquisition are described in detail in the subsequent chapters. However, regardless of the method of image formation, one must be able to judge the fidelity of the image in an attempt to answer the question “How accurately does the image portray the body or the bodily function?” This judgement falls under the rubric of ‘image quality’. In this chapter, methods of quantifying image quality are described.

  13. Video Golf

    Science.gov (United States)

    1995-01-01

    George Nauck of ENCORE!!! invented and markets the Advanced Range Performance (ARPM) Video Golf System for measuring the result of a golf swing. After Nauck requested their assistance, Marshall Space Flight Center scientists suggested video and image processing/computing technology, and provided leads on commercial companies that dealt with the pertinent technologies. Nauck contracted with Applied Research Inc. to develop a prototype. The system employs an elevated camera, which sits behind the tee and follows the flight of the ball down range, catching the point of impact and subsequent roll. Instant replay of the video on a PC monitor at the tee allows measurement of the carry and roll. The unit measures distance and deviation from the target line, as well as distance from the target when one is selected. The information serves as an immediate basis for making adjustments or as a record of skill level progress for golfers.

  14. Broadcast-quality-stereoscopic video in a time-critical entertainment and corporate environment

    Science.gov (United States)

    Gay, Jean-Philippe

    1995-03-01

    `reality present: Peter Gabrial and Cirque du Soleil' is a 12 minute original work directed and produced by Doug Brown, Jean-Philippe Gay & A. Coogan, which showcases creative content applications of commercial stereoscopic video equipment. For production, a complete equipment package including a Steadicam mount was used in support of the Ikegami LK-33 camera. Remote production units were fielded in the time critical, on-stage and off-stage environments of 2 major live concerts: Peter Gabriel's Secret World performance at the San Diego Sports Arena, and Cirque du Soleil's Saltimbanco performance in Chicago. Twin 60 Hz video channels were captured on Beta SP for maximum post production flexibility. Digital post production and field sequential mastering were effected in D-2 format at studio facilities in Los Angeles. The program was world premiered to a large public at the World of Music, Arts and Dance festivals in Los Angeles and San Francisco, in late 1993. It was presented to the artists in Los Angeles, Montreal and Washington D.C. Additional presentations have been made using a broad range of commercial and experimental stereoscopic video equipment, including projection systems, LCD and passive eyewear, and digital signal processors. Technical packages for live presentation have been fielded on site and off, through to the present.

  15. Beyond rain: Advances in measurements of solid or mixed phase precipitation using a 2D-Video-Distrometer

    Science.gov (United States)

    Schwinzerl, Martin; Schönhuber, Michael; Lammer, Günter

    2015-04-01

    -situ measurements of such mixed or solid precipitation. One of the biggest challenges identified in this specific field of application of the 2DVD is to reliably match the individual shapes gathered by the two cameras, especially in the presence of many potential matching partners during heavy and dense precipitation. By continuously refining of the established matching procedures originating from the rain measurements and adapting the parameters entering this matching algorithm, this challenge has been addressed with respect to the 2DVD. We will provide a summary of some of the recent developments and specific improvements in this area and will also outline the potential of applying the results found towards this end on the related development of a 1D-Video-Distrometer (1DVD), which in contrast to the 2DVD would have to rely on externally provided information in order to obtain a similar quality of results.

  16. A new multimodal interactive way of subjective scoring of 3D video quality of experience

    Science.gov (United States)

    Kim, Taewan; Lee, Kwanghyun; Lee, Sanghoon; Bovik, Alan C.

    2014-03-01

    People that watch today's 3D visual programs, such as 3D cinema, 3D TV and 3D games, experience wide and dynamically varying ranges of 3D visual immersion and 3D quality of experience (QoE). It is necessary to be able to deploy reliable methodologies that measure each viewers subjective experience. We propose a new methodology that we call Multimodal Interactive Continuous Scoring of Quality (MICSQ). MICSQ is composed of a device interaction process between the 3D display and a separate device (PC, tablet, etc.) used as an assessment tool, and a human interaction process between the subject(s) and the device. The scoring process is multimodal, using aural and tactile cues to help engage and focus the subject(s) on their tasks. Moreover, the wireless device interaction process makes it possible for multiple subjects to assess 3D QoE simultaneously in a large space such as a movie theater, and at di®erent visual angles and distances.

  17. Mixed Methods Approach for Measuring the Impact of Video Telehealth on Outpatient Clinic Triage Nurse Workflow

    Science.gov (United States)

    Cady, Rhonda G.; Finkelstein, Stanley M.

    2015-01-01

    Nurse-delivered telephone triage is a common component of outpatient clinic settings. Adding new communication technology to clinic triage has the potential to not only transform the triage process, but also alter triage workflow. Evaluating the impact of new technology on an existing workflow is paramount to maximizing efficiency of the delivery system. This study investigated triage nurse workflow before and after the implementation of video telehealth using a sequential mixed methods protocol that combined ethnography and time-motion study to provide a robust analysis of the implementation environment. Outpatient clinic triage using video telehealth required significantly more time than telephone triage, indicating a reduction in nurse efficiency. Despite the increased time needed to conduct video telehealth, nurses consistently rated it useful in providing triage. Interpretive analysis of the qualitative and quantitative data suggests the increased depth and breadth of data available during video triage alters the assessment triage nurses provide physicians. This in turn could impact the time physicians spend formulating a diagnosis and treatment plan. While the immediate impact of video telehealth is a reduction in triage nurse efficiency, what is unknown is the impact of video telehealth on physician and overall clinic efficiency. Future studies should address this area. PMID:24080753

  18. Measuring fish and their physical habitats: Versatile 2D and 3D video techniques with user-friendly software

    Science.gov (United States)

    Neuswanger, Jason R.; Wipfli, Mark S.; Rosenberger, Amanda E.; Hughes, Nicholas F.

    2017-01-01

    Applications of video in fisheries research range from simple biodiversity surveys to three-dimensional (3D) measurement of complex swimming, schooling, feeding, and territorial behaviors. However, researchers lack a transparently developed, easy-to-use, general purpose tool for 3D video measurement and event logging. Thus, we developed a new measurement system, with freely available, user-friendly software, easily obtained hardware, and flexible underlying mathematical methods capable of high precision and accuracy. The software, VidSync, allows users to efficiently record, organize, and navigate complex 2D or 3D measurements of fish and their physical habitats. Laboratory tests showed submillimetre accuracy in length measurements of 50.8 mm targets at close range, with increasing errors (mostly <1%) at longer range and for longer targets. A field test on juvenile Chinook salmon (Oncorhynchus tshawytscha) feeding behavior in Alaska streams found that individuals within aggregations avoided the immediate proximity of their competitors, out to a distance of 1.0 to 2.9 body lengths. This system makes 3D video measurement a practical tool for laboratory and field studies of aquatic or terrestrial animal behavior and ecology.

  19. The exploration of service quality and its measurement for private ...

    African Journals Online (AJOL)

    The strategic importance of service excellence for service industries places the focus on service quality leadership, service quality management systems, service quality dimensions and the measurement of service quality. Many businesses such as private higher education institutions (PHEIs) regard service quality ...

  20. Students Matter: Quality Measurements in Online Courses

    Science.gov (United States)

    Unal, Zafer; Unal, Aslihan

    2016-01-01

    Quality Matters (QM) is a peer review process designed to certify the quality of online courses and online components. It has generated widespread interest and received national recognition for its peer-based approach to quality assurance and continuous improvement in online education. While the entire QM online course design process is…

  1. HDR 192Ir source speed measurements using a high speed video camera

    International Nuclear Information System (INIS)

    Fonseca, Gabriel P.; Viana, Rodrigo S. S.; Yoriyaz, Hélio; Podesta, Mark; Rubo, Rodrigo A.; Sales, Camila P. de; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Purpose: The dose delivered with a HDR 192 Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a 192 Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulating the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases

  2. Quantitative comparison of measurements of urgent care service quality.

    Science.gov (United States)

    Qin, Hong; Prybutok, Victor; Prybutok, Gayle

    2016-01-01

    Service quality and patient satisfaction are essential to health care organization success. Parasuraman, Zeithaml, and Berry introduced SERVQUAL, a prominent service quality measure not yet applied to urgent care. We develop an instrument to measure perceived service quality and identify the determinants of patient satisfaction/ behavioral intentions. We examine the relationships among perceived service quality, patient satisfaction and behavioral intentions, and demonstrate that urgent care service quality is not equivalent using measures of perceptions only, differences of expectations minus perceptions, ratio of perceptions to expectations, and the log of the ratio. Perceptions provide the best measure of urgent care service quality.

  3. Influence of Continuing Medical Education on Rheumatologists' Performance on National Quality Measures for Rheumatoid Arthritis.

    Science.gov (United States)

    Sapir, Tamar; Rusie, Erica; Greene, Laurence; Yazdany, Jinoos; Robbins, Mark L; Ruderman, Eric M; Carter, Jeffrey D; Patel, Barry; Moreo, Kathleen

    2015-12-01

    In recent years researchers have reported deficits in the quality of care provided to patients with rheumatoid arthritis (RA), including low rates of performance on quality measures. We sought to determine the influence of a quality improvement (QI) continuing education program on rheumatologists' performance on national quality measures for RA, along with other measures aligned with National Quality Strategy priorities. Performance was assessed through baseline and post-education chart audits. Twenty community-based rheumatologists across the United States were recruited to participate in the QI education program and chart audits. Charts were retrospectively audited before (n = 160 charts) and after (n = 160 charts) the rheumatologists participated in a series of accredited QI-focused educational activities that included private audit feedback, small-group webinars, and online- and mobile-accessible print and video activities. The charts were audited for patient demographics and the rheumatologists' documented performance on the 6 quality measures for RA included in the Physician Quality Reporting System (PQRS). In addition, charts were abstracted for documentation of patient counseling about medication benefits/risks and adherence, lifestyle modifications, and quality of life; assessment of RA medication side effects; and assessment of RA medication adherence. Mean rates of documented performance on 4 of the 6 PQRS measures for RA were significantly higher in the post-education versus baseline charts (absolute increases ranged from 9 to 24% of patient charts). In addition, after the intervention, significantly higher mean rates were observed for patient counseling about medications and quality of life, and for assessments of medication side effects and adherence (absolute increases ranged from 9 to 40% of patient charts). This pragmatic study provides preliminary evidence for the positive influence of QI-focused education in helping rheumatologists improve

  4. Signal quality measures for unsupervised blood pressure measurement

    International Nuclear Information System (INIS)

    Abdul Sukor, J; Redmond, S J; Lovell, N H; Chan, G S H

    2012-01-01

    Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure

  5. SALE, Quality Control of Analytical Chemical Measurements

    International Nuclear Information System (INIS)

    Bush, W.J.; Gentillon, C.D.

    1985-01-01

    1 - Description of problem or function: The Safeguards Analytical Laboratory Evaluation (SALE) program is a statistical analysis program written to analyze the data received from laboratories participating in the SALE quality control and evaluation program. The system is aimed at identifying and reducing analytical chemical measurement errors. Samples of well-characterized materials are distributed to laboratory participants at periodic intervals for determination of uranium or plutonium concentration and isotopic distributions. The results of these determinations are statistically evaluated and participants are informed of the accuracy and precision of their results. 2 - Method of solution: Various statistical techniques produce the SALE output. Assuming an unbalanced nested design, an analysis of variance is performed, resulting in a test of significance for time and analyst effects. A trend test is performed. Both within- laboratory and between-laboratory standard deviations are calculated. 3 - Restrictions on the complexity of the problem: Up to 1500 pieces of data for each nuclear material sampled by a maximum of 75 laboratories may be analyzed

  6. Efficient data replication for the delivery of high-quality video content over P2P VoD advertising networks

    Science.gov (United States)

    Ho, Chien-Peng; Yu, Jen-Yu; Lee, Suh-Yin

    2011-12-01

    Recent advances in modern television systems have had profound consequences for the scalability, stability, and quality of transmitted digital data signals. This is of particular significance for peer-to-peer (P2P) video-on-demand (VoD) related platforms, faced with an immediate and growing demand for reliable service delivery. In response to demands for high-quality video, the key objectives in the construction of the proposed framework were user satisfaction with perceived video quality and the effective utilization of available resources on P2P VoD networks. This study developed a peer-based promoter to support online advertising in P2P VoD networks based on an estimation of video distortion prior to the replication of data stream chunks. The proposed technology enables the recovery of lost video using replicated stream chunks in real time. Load balance is achieved by adjusting the replication level of each candidate group according to the degree-of-distortion, thereby enabling a significant reduction in server load and increased scalability in the P2P VoD system. This approach also promotes the use of advertising as an efficient tool for commercial promotion. Results indicate that the proposed system efficiently satisfies the given fault tolerances.

  7. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors.

    Science.gov (United States)

    Cortes, Nelson; Lincoln, Andrew E; Myer, Gregory D; Hepburn, Lisa; Higgins, Michael; Putukian, Margot; Caswell, Shane V

    2017-08-01

    Wearable sensors are increasingly used to quantify the frequency and magnitude of head impact events in multiple sports. There is a paucity of evidence that verifies head impact events recorded by wearable sensors. To utilize video analysis to verify head impact events recorded by wearable sensors and describe the respective frequency and magnitude. Cohort study (diagnosis); Level of evidence, 2. Thirty male (mean age, 16.6 ± 1.2 years; mean height, 1.77 ± 0.06 m; mean weight, 73.4 ± 12.2 kg) and 35 female (mean age, 16.2 ± 1.3 years; mean height, 1.66 ± 0.05 m; mean weight, 61.2 ± 6.4 kg) players volunteered to participate in this study during the 2014 and 2015 lacrosse seasons. Participants were instrumented with GForceTracker (GFT; boys) and X-Patch sensors (girls). Simultaneous game video was recorded by a trained videographer using a single camera located at the highest midfield location. One-third of the field was framed and panned to follow the ball during games. Videographic and accelerometer data were time synchronized. Head impact counts were compared with video recordings and were deemed valid if (1) the linear acceleration was ≥20 g, (2) the player was identified on the field, (3) the player was in camera view, and (4) the head impact mechanism could be clearly identified. Descriptive statistics of peak linear acceleration (PLA) and peak rotational velocity (PRV) for all verified head impacts ≥20 g were calculated. For the boys, a total recorded 1063 impacts (2014: n = 545; 2015: n = 518) were logged by the GFT between game start and end times (mean PLA, 46 ± 31 g; mean PRV, 1093 ± 661 deg/s) during 368 player-games. Of these impacts, 690 were verified via video analysis (65%; mean PLA, 48 ± 34 g; mean PRV, 1242 ± 617 deg/s). The X-Patch sensors, worn by the girls, recorded a total 180 impacts during the course of the games, and 58 (2014: n = 33; 2015: n = 25) were verified via video analysis (32%; mean PLA, 39 ± 21 g; mean PRV, 1664

  8. ATM Quality of Service Parameters at 45 Mbps Using a Satellite Emulator: Laboratory Measurements

    Science.gov (United States)

    Ivancic, William D.; Bobinsky, Eric A.

    1997-01-01

    Results of 45-Mbps DS3 intermediate-frequency loopback measurements of asynchronous transfer mode (ATM) quality of service parameters (cell error ratio and cell loss ratio) are presented. These tests, which were conducted at the NASA Lewis Research Center in support of satellite-ATM interoperability research, represent initial efforts to quantify the minimum parameters for stringent ATM applications, such as MPEG-1 and MPEG-2 video transmission. Portions of these results were originally presented to the International Telecommunications Union's ITU-R Working Party 4B in February 1996 in support of their Draft Preliminary Recommendation on the Transmission of ATM Traffic via Satellite.

  9. What Is Nursing Home Quality and How Is It Measured?

    Science.gov (United States)

    Castle, Nicholas G.; Ferguson, Jamie C.

    2010-01-01

    Purpose: In this commentary, we examine nursing home quality and indicators that have been used to measure nursing home quality. Design and Methods: A brief review of the history of nursing home quality is presented that provides some context and insight into currently used quality indicators. Donabedian's structure, process, and outcome (SPO)…

  10. Innovative United Kingdom Approaches To Measuring Service Quality.

    Science.gov (United States)

    Winkworth, Ian

    2001-01-01

    Reports on approaches to measuring the service quality of academic libraries in the United Kingdom. Discusses the role of government and the national background of quality measurement; measurement frameworks; better use of statistics; benchmarking; measuring user satisfaction; and possible future development. (Author/LRW)

  11. Measuring the Quality of Professional Development Training

    Science.gov (United States)

    Gaumer Erickson, Amy S.; Noonan, Patricia M.; Brussow, Jennifer; Supon Carter, Kayla

    2017-01-01

    High-quality, evidence-based professional development is essential to ensure that teachers obtain the knowledge, strategies and skills necessary to positively impact student learning. While the primary form of professional development, training has rarely been evaluated for quality beyond the satisfaction of those being trained. The Observation…

  12. Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.

    Science.gov (United States)

    Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi

    2003-01-01

    The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.

  13. Competency-Based Education: A Framework for Measuring Quality Courses

    Science.gov (United States)

    Krause, Jackie; Dias, Laura Portolese; Schedler, Chris

    2015-01-01

    The growth of competency-based education in an online environment requires the development and measurement of quality competency-based courses. While quality measures for online courses have been developed and standardized, they do not directly align with emerging best practices and principles in the design of quality competency-based online…

  14. Perception Of Space, Empathy And Cognitive Processes: Design Of A Video Game For The Measurement Of Perspective Taking Skills

    Directory of Open Access Journals (Sweden)

    Pio Alfredo Di Tore

    2014-04-01

    Full Text Available The perspective-taking skills require the ability to manipulate spatial reference systems and are the basis of the empathetic process. Empathy, in its relations with space representation and manipulation of spatial reference systems, is the investigation subject of this work, whose aim is the design of a videogame aimed at the measurement of the player's perspective taking skills. The idea of creating a video game on perspective taking is based on a classic Piagetian task, the three mountains problem, object of recent attention by the Italian scientific community that is involved in research in education. The current stage of the project has produced a video game, now in alpha testing release. The article discusses the software theoretical framework (spatial theory of empathy, describes the choices made in the design stage and comment on first results obtained during the alpha testing.

  15. Risk Factor, Job Stress and Quality of Life in Workers With Lower Extremity Pain Who Use Video Display Terminals.

    Science.gov (United States)

    Choi, Sehoon; Jang, Seong Ho; Lee, Kyu Hoon; Kim, Mi Jung; Park, Si-Bog; Han, Seung Hoon

    2018-02-01

    To investigate the general characteristics of video display terminal (VDT) workers with lower extremity pain, to identify the risk factors of work-related lower extremity pain, and to examine the relationship between work stress and health-related quality of life. A questionnaire about the general characteristics of the survey group and the musculoskeletal symptom was used. A questionnaire about job stress used the Korean Occupational Stress Scale and medical outcome study 36-item Short Form Health Survey (SF-36) to assess health-related quality of life. There were 1,711 subjects in the lower extremity group and 2,208 subjects in the control group. Age, sex, hobbies, and feeling of loading affected lower extremity pain as determined in a crossover analysis of all variables with and without lower extremity pain. There were no statistically significant difference between the two groups in terms of job stress and SF-36 values of the pain and control groups. Job stress in VDT workers was higher than average, and the quality of life decreased as the stress increased. Factors such as younger age, women, hobbies other than exercise, and feeling of loading influenced lower extremity pain of workers. Further long-term follow-up and supplementary studies are needed to identify risk factors for future lower extremity pain, taking into account ergonomic factors such as worker's posture.

  16. A novel frame-level constant-distortion bit allocation for smooth H.264/AVC video quality

    Science.gov (United States)

    Liu, Li; Zhuang, Xinhua

    2009-01-01

    It is known that quality fluctuation has a major negative effect on visual perception. In previous work, we introduced a constant-distortion bit allocation method [1] for H.263+ encoder. However, the method in [1] can not be adapted to the newest H.264/AVC encoder directly as the well-known chicken-egg dilemma resulted from the rate-distortion optimization (RDO) decision process. To solve this problem, we propose a new two stage constant-distortion bit allocation (CDBA) algorithm with enhanced rate control for H.264/AVC encoder. In stage-1, the algorithm performs RD optimization process with a constant quantization QP. Based on prediction residual signals from stage-1 and target distortion for smooth video quality purpose, the frame-level bit target is allocated by using a close-form approximations of ratedistortion relationship similar to [1], and a fast stage-2 encoding process is performed with enhanced basic unit rate control. Experimental results show that, compared with original rate control algorithm provided by H.264/AVC reference software JM12.1, the proposed constant-distortion frame-level bit allocation scheme reduces quality fluctuation and delivers much smoother PSNR on all testing sequences.

  17. High-speed video analysis improves the accuracy of spinal cord compression measurement in a mouse contusion model.

    Science.gov (United States)

    Fournely, Marion; Petit, Yvan; Wagnac, Éric; Laurin, Jérôme; Callot, Virginie; Arnoux, Pierre-Jean

    2018-01-01

    Animal models of spinal cord injuries aim to utilize controlled and reproducible conditions. However, a literature review reveals that mouse contusion studies using equivalent protocols may show large disparities in the observed impact force vs. cord compression relationship. The overall purpose of this study was to investigate possible sources of bias in these measurements. The specific objective was to improve spinal cord compression measurements using a video-based setup to detect the impactor-spinal cord time-to-contact. A force-controlled 30kDyn unilateral contusion at C4 vertebral level was performed in six mice with the Infinite Horizon impactor (IH). High-speed video was used to determine the time-to-contact between the impactor tip and the spinal cord and to compute the related displacement of the tip into the tissue: the spinal cord compression and the compression ratio. Delayed time-to-contact detection with the IH device led to an underestimation of the cord compression. Compression values indicated by the IH were 64% lower than those based on video analysis (0.33mm vs. 0.88mm). Consequently, the mean compression ratio derived from the device was underestimated when compared to the value derived from video analysis (22% vs. 61%). Default time-to-contact detection from the IH led to significant errors in spinal cord compression assessment. Accordingly, this may explain some of the reported data discrepancies in the literature. The proposed setup could be implemented by users of contusion devices to improve the quantative description of the primary injury inflicted to the spinal cord. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Quality Measures for Digital Business Ecosystems Formation

    Science.gov (United States)

    Raza, Muhammad; Hussain, Farookh Khadeer; Chang, Elizabeth

    To execute a complex business task, business entities may need to collaborate with each other as individually they may not have the capability or willingness to perform the task on its own. Such collaboration can be seen implemented in digital business ecosystems in the form of simple coalitions using multi-agent systems or by employing Electronic Institutions. A major challenge is choosing optimal partners who will deliver the agreed commitments, and act in the coalition’s interest. Business entities are scaled according to their quality level. Determining the quality of previously unknown business entities and predicting the quality of such an entity in a dynamic environment are crucial issues in Business Ecosystems. A comprehensive quality management system grounded in the concepts of Trust and Reputation can help address these issues.

  19. Carbonate chemistry, water quality, coral measurements

    Data.gov (United States)

    U.S. Environmental Protection Agency — Carbonate chemistry parameters (pH, total alkalinity, and pCO2), water quality parameters (Temperature, salinity, Ca, Mg, PO4, NH3 and NO3) as well as all coral...

  20. Software process improvement, quality assurance and measurement

    NARCIS (Netherlands)

    Trienekens, J.J.M.; Kusters, R.J.; Balla, K.; Kontogiannis, K.; Zou, Y.; Di Penta, M.

    2006-01-01

    The aim of this workshop was to present and discuss emergent software quality improvement approaches, with an emphasis on practical applications. Different views on the improvement of software processes, software products, and their interrelations, have been addressed during the workshop.

  1. A fourier transform quality measure for iris images

    CSIR Research Space (South Africa)

    Makinana, S

    2014-08-01

    Full Text Available to ensure that good quality images are selected for feature extraction, in order to improve iris recognition system. In addition, this research proposes a measure of iris image quality using a Fourier Transform. The experimental results demonstrate...

  2. Measuring educational heterogeneity and labor quality

    DEFF Research Database (Denmark)

    Fosgerau, Mogens; Hougaard Jensen, Svend E.; Sørensen, Anders

    2002-01-01

    This paper investigates the magnitude of the mismeasurement that occurs when only a few education categories are used in the construction of a constant quality index for labor input. By employing a very comprehensive data set it is found that the error resulting from the omission of information...... on education is relatively small. The empirical results are thus supportive of the current state of practice of constructing indices of constant quality labor input....

  3. Measurement of Quality to Improve Care in Sleep Medicine

    OpenAIRE

    Morgenthaler, Timothy I.; Aronsky, Amy J.; Carden, Kelly A.; Chervin, Ronald D.; Thomas, Sherene M.; Watson, Nathaniel F.

    2015-01-01

    The Board of Directors of the American Academy of Sleep Medicine (AASM) commissioned a Task Force to develop quality measures as part of its strategic plan to promote high quality patient-centered care. Among many potential dimensions of quality, the AASM requested Workgroups to develop outcome and process measures to aid in evaluating the quality of care of five common sleep disorders: restless legs syndrome, insomnia, narcolepsy, obstructive sleep apnea in adults, and obstructive sleep apne...

  4. A No-Reference Modular Video Quality Prediction Model for H.265/HEVC and VP9 Codecs on a Mobile Device

    Directory of Open Access Journals (Sweden)

    Debajyoti Pal

    2017-01-01

    Full Text Available We propose a modular no-reference video quality prediction model for videos that are encoded with H.265/HEVC and VP9 codecs and viewed on mobile devices. The impairments which can affect video transmission are classified into two broad types depending upon which layer of the TCP/IP model they originated from. Impairments from the network layer are called the network QoS factors, while those from the application layer are called the application/payload QoS factors. Initially we treat the network and application QoS factors separately and find out the 1 : 1 relationship between the respective QoS factors and the corresponding perceived video quality or QoE. The mapping from the QoS to the QoE domain is based upon a decision variable that gives an optimal performance. Next, across each group we choose multiple QoS factors and find out the QoE for such multifactor impaired videos by using an additive, multiplicative, and regressive approach. We refer to these as the integrated network and application QoE, respectively. At the end, we use a multiple regression approach to combine the network and application QoE for building the final model. We also use an Artificial Neural Network approach for building the model and compare its performance with the regressive approach.

  5. Measuring data quality for ongoing improvement a data quality assessment framework

    CERN Document Server

    Sebastian-Coleman, Laura

    2013-01-01

    The Data Quality Assessment Framework shows you how to measure and monitor data quality, ensuring quality over time. You'll start with general concepts of measurement and work your way through a detailed framework of more than three dozen measurement types related to five objective dimensions of quality: completeness, timeliness, consistency, validity, and integrity. Ongoing measurement, rather than one time activities will help your organization reach a new level of data quality. This plain-language approach to measuring data can be understood by both business and IT and provides pra

  6. Objective assessment of the impact of frame rate on video quality

    DEFF Research Database (Denmark)

    Ukhanova, Ann; Korhonen, Jari; Forchhammer, Søren

    2012-01-01

    In this paper, we present a novel objective quality metric that takes the impact of frame rate into account. The proposed metric uses PSNR, frame rate and a content dependent parameter that can easily be obtained from spatial and temporal activity indices. The results have been validated on data ...

  7. Does peer coaching with video feedback improve the quality of teachers' reflections on own professional behaviour?

    NARCIS (Netherlands)

    J. van den Akker; dr Rita Schildwacht; Dr. S. Bolhuis

    2008-01-01

    Meetings with other professionals are considered crucial for enhancing the quality of teachers' reflections. However, little is yet known about how any beneficial effects of such meetings are brought about. This study explores the peer coach's roles and their influences on the learning processes of

  8. MOOC Quality: The Need for New Measures

    Science.gov (United States)

    Hood, Nina; Littlejohn, Allison

    2016-01-01

    MOOCs are re-operationalising traditional concepts in education. While they draw on elements of existing educational and learning models, they represent a new approach to instruction and learning. The challenges MOOCs present to traditional education models have important implications for approaching and assessing quality. This paper foregrounds…

  9. The quality of measurements a metrological reference

    CERN Document Server

    Fridman, A E

    2012-01-01

    This book provides a detailed discussion and commentary on the fundamentals of metrology. The fundamentals of metrology, the principles underlying the design of the SI International System of units, the theory of measurement error, a new methodology for estimation of measurement accuracy based on uncertainty, and methods for reduction of measured results and estimation of measurement uncertainty are all discussed from a modern point of view. The concept of uncertainty is shown to be consistent with the classical theory of accuracy. The theory of random measurement errors is supplemented by a very general description based on the generalized normal distribution; systematic instrumental error is described in terms of a methodology for normalizing the metrological characteristics of measuring instruments. A new international system for assuring uniformity of measurements based on agreements between national metrological institutes is discussed, in addition to the role and procedure for performance of key compari...

  10. Quality Measures for the Care of Patients with Insomnia

    Science.gov (United States)

    Edinger, Jack D.; Buysse, Daniel J.; Deriy, Ludmila; Germain, Anne; Lewin, Daniel S.; Ong, Jason C.; Morgenthaler, Timothy I.

    2015-01-01

    The American Academy of Sleep Medicine (AASM) commissioned five Workgroups to develop quality measures to optimize management and care for patients with common sleep disorders including insomnia. Following the AASM process for quality measure development, this document describes measurement methods for two desirable outcomes of therapy, improving sleep quality or satisfaction, and improving daytime function, and for four processes important to achieving these goals. To achieve the outcome of improving sleep quality or satisfaction, pre- and post-treatment assessment of sleep quality or satisfaction and providing an evidence-based treatment are recommended. To realize the outcome of improving daytime functioning, pre- and post-treatment assessment of daytime functioning, provision of an evidence-based treatment, and assessment of treatment-related side effects are recommended. All insomnia measures described in this report were developed by the Insomnia Quality Measures Workgroup and approved by the AASM Quality Measures Task Force and the AASM Board of Directors. The AASM recommends the use of these measures as part of quality improvement programs that will enhance the ability to improve care for patients with insomnia. Citation: Edinger JD, Buysse DJ, Deriy L, Germain A, Lewin DS, Ong JC, Morgenthaler TI. Quality measures for the care of patients with insomnia. J Clin Sleep Med 2015;11(3):311–334. PMID:25700881

  11. Measuring the Multifaceted Nature of Infant and Toddler Care Quality

    Science.gov (United States)

    Mangione, Peter L.; Kriener-Althen, Kerry; Marcella, Jennifer

    2016-01-01

    Research Findings: The quality of group care infants and toddlers experience relates to their concurrent and later development. Recent quality improvement initiatives point to the need for ecologically valid measures that assess the multifaceted nature of child care quality. In this article, we present the psychometric properties of an infant and…

  12. Measuring the quality of eligible collateral

    OpenAIRE

    Lehmbecker, Philipp; Missong, Martin

    2008-01-01

    Recently, the U. S. subprime crisis has shown that a weak collateralization of credits may have massive economic implications, entailing severe perturbations of the international financial system. We focus on central bank lending and try to pin down the quantitative impact of the collateralization of central banks' credits. A questionnaire on national monetary frameworks was used to collect data from central banks. Drawing on these data we derive an index of the quality of eligible assets mea...

  13. On Quality and Measures in Software Engineering

    Science.gov (United States)

    Bucur, Ion I.

    2006-01-01

    Complexity measures are mainly used to estimate vital information about reliability and maintainability of software systems from regular analysis of the source code. Such measures also provide constant feedback during a software project to assist the control of the development procedure. There exist several models to classify a software product's…

  14. The quality infrastructure measuring, analyzing, and improving library services

    CERN Document Server

    Murphy, Sarah Anne

    2013-01-01

    Summarizing specific tools for measuring service quality alongside tips for using these tools most effectively, this book helps libraries of all kinds take a programmatic approach to measuring, analyzing, and improving library services.

  15. Vigilance on the move: video game-based measurement of sustained attention.

    Science.gov (United States)

    Szalma, J L; Schmidt, T N; Teo, G W L; Hancock, P A

    2014-01-01

    Vigilance represents the capacity to sustain attention to any environmental source of information over prolonged periods on watch. Most stimuli used in vigilance research over the previous six decades have been relatively simple and often purport to represent important aspects of detection and discrimination tasks in real-world settings. Such displays are most frequently composed of single stimulus presentations in discrete trials against a uniform, often uncluttered background. The present experiment establishes a dynamic, first-person perspective vigilance task in motion using a video-game environment. 'Vigilance on the move' is thus a new paradigm for the study of sustained attention. We conclude that the stress of vigilance extends to the new paradigm, but whether the performance decrement emerges depends upon specific task parameters. The development of the task, the issues to be resolved and the pattern of performance, perceived workload and stress associated with performing such dynamic vigilance are reported. The present experiment establishes a dynamic, first-person perspective movement-based vigilance task using a video-game environment. 'Vigilance on the move' is thus a new paradigm for the evaluation of sustained attention in operational environments in which individuals move as they monitor their environment. Issues addressed in task development are described.

  16. Sound for digital video

    CERN Document Server

    Holman, Tomlinson

    2013-01-01

    Achieve professional quality sound on a limited budget! Harness all new, Hollywood style audio techniques to bring your independent film and video productions to the next level.In Sound for Digital Video, Second Edition industry experts Tomlinson Holman and Arthur Baum give you the tools and knowledge to apply recent advances in audio capture, video recording, editing workflow, and mixing to your own film or video with stunning results. This fresh edition is chockfull of techniques, tricks, and workflow secrets that you can apply to your own projects from preproduction

  17. Measuring Quality in Online Education: A Meta-Synthesis

    Science.gov (United States)

    Esfijani, Azam

    2018-01-01

    This article presents a meta-synthesis review of quality of online education (QOE) measurement approaches. In order to survey the existing body of knowledge, a qualitative method was employed to investigate what quality of online education is comprised of and how the concept has been measured through the literature. To achieve this, a total of 112…

  18. Measuring quality of life in first-episode psychosis

    DEFF Research Database (Denmark)

    Melle, I; Friis, Svein; Haahr, U

    2005-01-01

    Quality of life (QoL) measures are increasingly recognized as necessary parts of outcome assessments in psychosis. The present paper is a comprehensive study of patients with first-episode psychosis where QoL is measured by the commonly used Lehman Quality of Life Interview (L-QoLI). The aim...

  19. A STUDY ON QUALITY ANALYSIS MEASURING PROCESS

    Directory of Open Access Journals (Sweden)

    Liliana LUCA

    2016-12-01

    Full Text Available The paper presents the results of a study concerning the use of the Ishikawa diagram in analyzing the causes that determine errors in the measuring the sizes of the pieces of machine construction field. The studied problem was "errors in the measurement process” and this constitutes the head of the Ishikawa diagram skeleton.All the possible, main and secondary causes that could generate the studied problem were identified. The paper shows the potential causes of the studied problem, which were firstly grouped in fives categories, as follows: man/people methods, machines/ measuring devices, material/ piece of measured, environment. Performing the Ishikawa diagram in a more detailed form in order to determine the potential causes of a found defect has the advantage that it offers the possibility to identify and analyze all factors, which relate to the problem studied. The paper presented a formula for the Ishikawa diagram was determined, 4M+E.

  20. Measuring Quality of Care Under Medicare and Medicaid

    OpenAIRE

    Jencks, Stephen F.

    1995-01-01

    The Health Care Financing Administration's (HCFA) approach to measuring quality of care uses an accepted definition of quality, explicit domains of measurement, and a formal validation procedure that includes face validity, construct validity, reliability, clinical validation, and tests for usefulness. The indicators of quality for Medicare and Medicaid patients span the range of service types, medical conditions, and payment systems and rest on a variety of data systems. Some have already be...

  1. A STUDY ON QUALITY ANALYSIS MEASURING PROCESS

    OpenAIRE

    Liliana LUCA

    2016-01-01

    The paper presents the results of a study concerning the use of the Ishikawa diagram in analyzing the causes that determine errors in the measuring the sizes of the pieces of machine construction field. The studied problem was "errors in the measurement process” and this constitutes the head of the Ishikawa diagram skeleton.All the possible, main and secondary causes that could generate the studied problem were identified. The paper shows the potential causes of the studied proble...

  2. Measuring environmental quality. An index of pollution

    International Nuclear Information System (INIS)

    Khanna, N.

    2000-01-01

    This paper develops an index of pollution based on the epidemiological dose-response function associated with each pollutant, and the welfare losses due to exposure to pollution. The probability of damage is translated into welfare losses, which provides the common metric required for aggregation. Isopollution surfaces may then be used to compare environmental quality over time and space. An Air Pollution Index (API) is computed using 1997 data for the criteria pollutants under the Clean Air Act (CAA). The results are compared with the EPA's Pollutant Standards Index (PSI). Two significant differences emerge: unlike the PSI, the API facilitates a detailed ranking of regions by air quality and API values may contradict PSI results. Some regions with PSI values of 100-200 are considered less polluted under the proposed methodology than those with PSI values between 50 and 100. The key reason for the difference is that PSI values are determined entirely by the gas with the highest relative concentration whereas the API value is based on the ambient concentrations of all pollutants. 14 refs

  3. Measuring quality of care: considering conceptual approaches to quality indicator development and evaluation.

    Science.gov (United States)

    Stelfox, Henry T; Straus, Sharon E

    2013-12-01

    In this article, we describe one approach for developing and evaluating quality indicators. We focus on describing different conceptual approaches to quality indicator development, review one approach for developing quality indicators, outline how to evaluate quality indicators once developed, and discuss quality indicator maintenance. The key steps for developing quality indicators include specifying a clear goal for the indicators; using methodologies to incorporate evidence, expertise, and patient perspectives; and considering contextual factors and logistics of implementation. The Strategic Framework Board and the National Quality Measure Clearinghouse have developed criteria for evaluating quality indicators that complement traditional psychometric evaluations. Optimal strategies for quality indicator maintenance and dissemination have not been determined, but experiences with clinical guideline maintenance may be informative. For quality indicators to effectively guide quality improvement efforts, they must be developed, evaluated, maintained, and implemented using rigorous evidence-informed practices. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. On use of image quality metrics for perceptual blur modeling: image/video compression case

    Science.gov (United States)

    Cha, Jae H.; Olson, Jeffrey T.; Preece, Bradley L.; Espinola, Richard L.; Abbott, A. Lynn

    2018-02-01

    Linear system theory is employed to make target acquisition performance predictions for electro-optical/infrared imaging systems where the modulation transfer function (MTF) may be imposed from a nonlinear degradation process. Previous research relying on image quality metrics (IQM) methods, which heuristically estimate perceived MTF has supported that an average perceived MTF can be used to model some types of degradation such as image compression. Here, we discuss the validity of the IQM approach by mathematically analyzing the associated heuristics from the perspective of reliability, robustness, and tractability. Experiments with standard images compressed by x.264 encoding suggest that the compression degradation can be estimated by a perceived MTF within boundaries defined by well-behaved curves with marginal error. Our results confirm that the IQM linearizer methodology provides a credible tool for sensor performance modeling.

  5. Adolescent sleep quality measured during leisure activities

    Directory of Open Access Journals (Sweden)

    Kathy Sexton-Radek

    2013-07-01

    Full Text Available A one-week sleep monitoring by logs and actigraphs in preteens during summer camp was conducted. Campers aged 11-16 attended a two-week day camp that focused on the learning about science. Nine campers agreed to monitor their sleep and have their patterns explained (anonymously to other campers during the expert lecture by the author. The aim of the study was to identify the sleep quality in an adolescent group. All nine of the sleep logs and actigraphs denoted severe sleep deprivation. The findings from the logs and actigraphs denoted sever sleep deprivation. The expert lecturer provided basic information about sleep per the science designation of the day camp. A follow up session provided strategies to address sleep deprivation

  6. Measuring Quality Satisfaction with Servqual Model

    Directory of Open Access Journals (Sweden)

    Dan Păuna

    2012-05-01

    Full Text Available The orientation to customer satisfaction is not a recent phenomenon, many very successfulbusinesspeople from the beginning of the 20th century, such as Sir Henry Royce, a name synonymous withRoll – Royce vehicles, stated the first principle regarding customer satisfaction “Our interest in the Roll-Royce cars does not end at the moment when the owner pays for and takes delivery the car. Our interest in thecar never wanes. Our ambition is that every purchaser of the Rolls - Royce car shall continue to be more thansatisfied (Rolls-Royce.” The following paper tries to deal with the important qualities of the concept for themeasuring of the gap between expected costumer services satisfactions, and perceived services like a routinecustomer feedback process, by means of a relatively new model, the Servqual model.

  7. Traffic Management of Video on Demand: An Analysis of Investments for Improving the End User’s Quality of Experience

    Directory of Open Access Journals (Sweden)

    Francesca Di Pillo

    2016-05-01

    Full Text Available The current escalation in user demand for web contents, particularly Video on Demand (VoD, is causing a continu‐ ing increase in both the types of web traffic and the volumes of data transmitted. The greater demand arises from the new means of communication employed by individuals and companies, as well as the development of readily usable applications distributed by ‘app stores’. In this paper, we suggest that the stakeholders of a VoD frame‐ work, the Content Providers (CPs and the Internet Service Providers (telcos/ISPs, should guarantee a solid Quality of Experience (QoE to the end user through two potential investments: either in ultra-broadband (UBB or in the technologies for the acceleration of web content, known as the Content Delivery Network (CDN and Transparent Internet Caching (TIC. The aim of the paper is to analyse these investments in terms of providers' profits. The base hypothesis is that the investments are subsidized by the CPs, which, in recent years, have indeed been directing a large part of their revenues towards investments in network infrastructure.

  8. Measuring Quality and Outcomes in Sports Medicine.

    Science.gov (United States)

    Ruzbarsky, Joseph J; Marom, Niv; Marx, Robert G

    2018-07-01

    Patient-reported outcome measures (PROMs) are objective metrics critical to evaluating outcomes throughout orthopedic surgery. New instruments continue to emerge, increasing the breadth of information required for those intending to use these measures for research or clinical care. Although earlier metrics were developed using the principles of classic test theory, newer instruments constructed using item response theory are amenable to computer-adaptive testing and may change the way these instruments are administered. This article aims to define the psychometric properties that are important to understand when using all PROMs and to review the most widely used instruments in sports medicine. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Cherenkov Detector for Beam Quality Measurement

    CERN Document Server

    AUTHOR|(CDS)2078842

    2016-01-01

    A new detector to measure the machine induced background at larger radiihas been developed and installed in the CMS experiment at LHC. Itconsists of 40 modules, each comprising a quartz bar read out by aphotomultiplier. Since Cerenkov radiation is emitted in a forward conearound the charged particle trajectory, these detectors can distinguishthe directions of the machine induced background.The back-end consists of a microTCA readout with excellent time resolution.The performance of the detector modules measured in several test-beamcampaigns will be reported. The installation in CMS will be described, andfirst results about operating the detector during data taking will begiven.

  10. Striking Distance Determined From High-Speed Videos and Measured Currents in Negative Cloud-to-Ground Lightning

    Science.gov (United States)

    Visacro, Silverio; Guimaraes, Miguel; Murta Vale, Maria Helena

    2017-12-01

    First and subsequent return strokes' striking distances (SDs) were determined for negative cloud-to-ground flashes from high-speed videos exhibiting the development of positive and negative leaders and the pre-return stroke phase of currents measured along a short tower. In order to improve the results, a new criterion was used for the initiation and propagation of the sustained upward connecting leader, consisting of a 4 A continuous current threshold. An advanced approach developed from the combined use of this criterion and a reverse propagation procedure, which considers the calculated propagation speeds of the leaders, was applied and revealed that SDs determined solely from the first video frame showing the upward leader can be significantly underestimated. An original approach was proposed for a rough estimate of first strokes' SD using solely records of current. This approach combines the 4 A criterion and a representative composite three-dimensional propagation speed of 0.34 × 106 m/s for the leaders in the last 300 m propagated distance. SDs determined under this approach showed to be consistent with those of the advanced procedure. This approach was applied to determine the SD of 17 first return strokes of negative flashes measured at MCS, covering a wide peak-current range, from 18 to 153 kA. The estimated SDs exhibit very high dispersion and reveal great differences in relation to the SDs estimated for subsequent return strokes and strokes in triggered lightning.

  11. Experimental Investigation of Aeroelastic Deformation of Slender Wings at Supersonic Speeds Using a Video Model Deformation Measurement Technique

    Science.gov (United States)

    Erickson, Gary E.

    2013-01-01

    A video-based photogrammetric model deformation system was established as a dedicated optical measurement technique at supersonic speeds in the NASA Langley Research Center Unitary Plan Wind Tunnel. This system was used to measure the wing twist due to aerodynamic loads of two supersonic commercial transport airplane models with identical outer mold lines but different aeroelastic properties. One model featured wings with deflectable leading- and trailing-edge flaps and internal channels to accommodate static pressure tube instrumentation. The wings of the second model were of single-piece construction without flaps or internal channels. The testing was performed at Mach numbers from 1.6 to 2.7, unit Reynolds numbers of 1.0 million to 5.0 million, and angles of attack from -4 degrees to +10 degrees. The video model deformation system quantified the wing aeroelastic response to changes in the Mach number, Reynolds number concurrent with dynamic pressure, and angle of attack and effectively captured the differences in the wing twist characteristics between the two test articles.

  12. Light-reflection random-target method for measurement of the modulation transfer function of a digital video-camera

    Science.gov (United States)

    Pospisil, J.; Jakubik, P.; Machala, L.

    2005-11-01

    This article reports the suggestion, realization and verification of the newly developed measuring means of the noiseless and locally shift-invariant modulation transfer function (MTF) of a digital video camera in a usual incoherent visible region of optical intensity, especially of its combined imaging, detection, sampling and digitizing steps which are influenced by the additive and spatially discrete photodetector, aliasing and quantization noises. Such means relates to the still camera automatic working regime and static two-dimensional spatially continuous light-reflection random target of white-noise property. The introduced theoretical reason for such a random-target method is also performed under exploitation of the proposed simulation model of the linear optical intensity response and possibility to express the resultant MTF by a normalized and smoothed rate of the ascertainable output and input power spectral densities. The random-target and resultant image-data were obtained and processed by means of a processing and evaluational PC with computation programs developed on the basis of MATLAB 6.5E The present examples of results and other obtained results of the performed measurements demonstrate the sufficient repeatability and acceptability of the described method for comparative evaluations of the performance of digital video cameras under various conditions.

  13. Plant iodine-131 uptake in relation to root concentration as measured in minirhizotron by video camera:

    International Nuclear Information System (INIS)

    Moss, K.J.

    1990-09-01

    Glass viewing tubes (minirhizotrons) were placed in the soil beneath native perennial bunchgrass (Agropyron spicatum). The tubes provided access for observing and quantifying plant roots with a miniature video camera and soil moisture estimates by neutron hydroprobe. The radiotracer I-131 was delivered to the root zone at three depths with differing root concentrations. The plant was subsequently sampled and analyzed for I-131. Plant uptake was greater when I-131 was applied at soil depths with higher root concentrations. When I-131 was applied at soil depths with lower root concentrations, plant uptake was less. However, the relationship between root concentration and plant uptake was not a direct one. When I-131 was delivered to deeper soil depths with low root concentrations, the quantity of roots there appeared to be less effective in uptake than the same quantity of roots at shallow soil depths with high root concentration. 29 refs., 6 figs., 11 tabs

  14. Rheumatoid Arthritis Educational Video Series

    Medline Plus

    Full Text Available ... Corner / Patient Webcasts / Rheumatoid Arthritis Educational Video Series Rheumatoid Arthritis Educational Video Series This series of five videos ... Your Arthritis Managing Chronic Pain and Depression in Arthritis Nutrition & Rheumatoid Arthritis Arthritis and Health-related Quality of Life ...

  15. Conceptualizing and Measuring the Quality of Democracy: The Citizens’ Perspective

    Directory of Open Access Journals (Sweden)

    Dieter Fuchs

    2018-03-01

    Full Text Available In recent years, several measurements of the quality of democracy have been developed (e.g. Democracy Barometer, Varieties of Democracy Project. These objective measurements focus on institutional and procedural characteristics of democracy. This article starts from the premise that in order to fully understand the quality of democracy such objective measurements have to be complemented by subjective measurements based on the perspective of citizens. The aim of the article is to conceptualize and measure the subjective quality of democracy. First, a conceptualization of the subjective quality of democracy is developed consisting of citizens’ support for three normative models of democracy (electoral, liberal, and direct democracy. Second, based on the World Values Survey 2005–2007, an instrument measuring these different dimensions of the subjective quality of democracy is suggested. Third, distributions for different models of democracy are presented for some European and non-European liberal democracies. They reveal significant differences regarding the subjective quality of democracies. Fourth, the subjective quality of democracy of these countries is compared with the objective quality of democracy based on three indices (electoral democracy, liberal democracy and direct popular vote developed by the Varieties of Democracy (V-Dem Project. Finally, further research questions are discussed.

  16. Dashboard Videos

    Science.gov (United States)

    Gleue, Alan D.; Depcik, Chris; Peltier, Ted

    2012-01-01

    Last school year, I had a web link emailed to me entitled "A Dashboard Physics Lesson." The link, created and posted by Dale Basier on his "Lab Out Loud" blog, illustrates video of a car's speedometer synchronized with video of the road. These two separate video streams are compiled into one video that students can watch and analyze. After seeing…

  17. Quality measures and assurance for AI (Artificial Intelligence) software

    Science.gov (United States)

    Rushby, John

    1988-01-01

    This report is concerned with the application of software quality and evaluation measures to AI software and, more broadly, with the question of quality assurance for AI software. Considered are not only the metrics that attempt to measure some aspect of software quality, but also the methodologies and techniques (such as systematic testing) that attempt to improve some dimension of quality, without necessarily quantifying the extent of the improvement. The report is divided into three parts Part 1 reviews existing software quality measures, i.e., those that have been developed for, and applied to, conventional software. Part 2 considers the characteristics of AI software, the applicability and potential utility of measures and techniques identified in the first part, and reviews those few methods developed specifically for AI software. Part 3 presents an assessment and recommendations for the further exploration of this important area.

  18. Standards for measurements and testing of wind turbine power quality

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, P [Risoe National Lab., Roskilde (Denmark); Gerdes, G; Klosse, R; Santjer, F [DEWI, Wilhelmshaven (Germany); Robertson, N; Davy, W [NEL, Glasgow (United Kingdom); Koulouvari, M; Morfiadakis, E [CRES, Pikermi (Greece); Larsson, Aa [Chalmers Univ. of Technology, Goeteborg (Sweden)

    1999-03-01

    The present paper describes the work done in power quality sub-task of the project `European Wind Turbine Testing Procedure Developments` funded by the EU SMT program. The objective of the power quality sub-task has been to make analyses and new recommendation(s) for the standardisation of measurement and verification of wind turbine power quality. The work has been organised in three major activities. The first activity has been to propose measurement procedures and to verify existing and new measurement procedures. This activity has also involved a comparison of the measurements and data processing of the participating partners. The second activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with constant rotor speed. The third activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with variable rotor speed. (au)

  19. Understanding Quality Measures in Otolaryngology–Head and Neck Surgery

    Science.gov (United States)

    Vila, Peter M.; Schneider, John S.; Piccirillo, Jay F.; Lieu, Judith E. C.

    2017-01-01

    As health care reimbursements based on pay-for-performance models become more common, there is an unprecedented demand for ways to measure health care quality and demonstrate value. Performance measures, a type of quality measure, are unique tools in a health care delivery system that allow objective monitoring of adherence to specific goals and tracking of outcomes. We sought to provide information on the development of quality measures in otolaryngology–head and neck surgery, as well as the goals of performance measurement at a national level and for our specialty. The historical development, various types, and approach to creating effective performance measures are discussed. The primary methods of developing performance measures (using clinical practice guidelines, clinical registries, and alternative methods) are also discussed. Performance measures are an important tool that can aid otolaryngologists in achieving effective, efficient, equitable, timely, safe, and patient-centered care as outlined by the Institute of Medicine. PMID:26606715

  20. Measuring patient-perceived hospital service quality: a conceptual framework.

    Science.gov (United States)

    Pai, Yogesh P; Chary, Satyanarayana T

    2016-04-18

    Purpose - Although measuring healthcare service quality is not a new phenomenon, the instruments used to measure are timeworn. With the shift in focus to patient centric processes in hospitals and recognizing healthcare to be different compared to other services, service quality measurement needs to be tuned specifically to healthcare. The purpose of this paper is to design a conceptual framework for measuring patient perceived hospital service quality (HSQ), based on existing service quality literature. Design/methodology/approach - Using HSQ theories, expanding existing healthcare service models and literature, a conceptual framework is proposed to measure HSQ. The paper outlines patient perceived service quality dimensions. Findings - An instrument for measuring HSQ dimensions is developed and compared with other service quality measuring instruments. The latest dimensions are in line with previous studies, but a relationship dimension is added. Practical implications - The framework empowers managers to assess healthcare quality in corporate, public and teaching hospitals. Originality/value - The paper helps academics and practitioners to assess HSQ from a patient perspective.

  1. Time focused measurements of roof runoff quality

    International Nuclear Information System (INIS)

    Schriewer, A.; Horn, H.; Helmreich, B.

    2008-01-01

    Runoff properties and their changes during runoff of a 14 year old zinc roof were investigated. Zinc, lead, cadmium, pH value, rain intensity and electric conductivity have been measured for a period of one year. A runoff rate of 3.73 g/m 2 a and a volume weighted mean zinc concentration of 4.9 mg/L were determined. First flush behaviour was observed in 93% of runoff events. Low rain intensities are correlating with higher zinc concentrations in runoff, whereas the duration of antecedent dry periods could not directly be linked with initial zinc concentrations

  2. Measurement of the exposure rate due to low energy x-rays emitted from video display terminals

    International Nuclear Information System (INIS)

    Campos, L.L.

    1988-01-01

    Thermoluminescent dosimeters of CaSO 4 :Dy have been used to measure the low energy x-rays emitted from Video Display Terminals (VDTs). For each terminal, three points were measured with five dosimeters at each point. The points were at distances of 5 and 50 cm in front of the screen and at 65 cm with an angle of approximately 50 0 . The last two positions approximate to positions of the lenses of the eye and the gonads respectively. A survey of 50 VDTs at a distance of 5 cm from the screen resulted in exposure rates nearly fifteen times below the exposure rate of 0.5 mR h -1 (0.129 μC kg -1 h -1 ) which is the limit recommended by the International Atomic Energy Agency (IAEA), Safety Series No. 9 (1967) Basic Safety Standards for Radiation Protection. (author)

  3. Video microblogging

    DEFF Research Database (Denmark)

    Bornoe, Nis; Barkhuus, Louise

    2010-01-01

    Microblogging is a recently popular phenomenon and with the increasing trend for video cameras to be built into mobile phones, a new type of microblogging has entered the arena of electronic communication: video microblogging. In this study we examine video microblogging, which is the broadcasting...... of short videos. A series of semi-structured interviews offers an understanding of why and how video microblogging is used and what the users post and broadcast....

  4. Measuring quality in services for children with an intellectual disability.

    Science.gov (United States)

    Koornneef, Erik

    2006-01-01

    To evaluate the application of one particular quality measurement tool, the SERVQUAL instrument, as a potential mechanism to measure quality in services for children with disabilities Staff and family of children with an intellectual disability in two organisations providing specialist therapy and day completed an adapted SERVQUAL questionnaire. A total of 81 SERVQUAL questionnaires were distributed and 59 questionnaires were returned (response rate of 73 per cent). The SERVQUAL instrument can be considered as a useful diagnostic tool to identify particular strengths and areas for improvement in services for people with disabilities as the instrument lends itself for the monitoring of the effectiveness of quality improvement initiatives over time. The findings also showed relatively high customer expectations and the organisations involved in this research are currently not meeting all of these high expectations as significant quality gaps were found in the areas of reliability and responsiveness. The sample size was relatively small and the measurement of quality using the SERVQUAL instrument remains a challenge, due to the conceptual and empirical difficulties. The SERVQUAL instrument is probably most be attractive to service managers and funding organisations because of its ability to identify gaps in the quality of the service. The tool had been used to measure quality in services for people with disabilities and the research has shown that this tool might be an important additional quality measurement tool for services.

  5. Violent Video Games and Children’s Aggressive Behaviors

    Directory of Open Access Journals (Sweden)

    Luca Milani

    2015-08-01

    Full Text Available The literature provides some evidence that the use of violent video games increases the risk for young people to develop aggressive cognitions and even behaviors. We aimed to verify whether exposure to violent video games is linked to problems of aggression in a sample of Italian children. Four questionnaires were administered to 346 children between 7 and 14 years of age, attending primary and secondary schools in Northern Italy. Variables measured were externalization, quality of interpersonal relationships, aggression, quality of coping strategies, and parental stress. Participants who preferred violent games showed higher scores for externalization and aggression. The use of violent video games and age were linked to higher levels of aggression, coping strategies, and the habitual video game weekly consumption of participants. Our data confirm the role of violent video games as risk factors for problems of aggressive behavior and of externalization in childhood and early adolescence.

  6. Secure and Efficient Reactive Video Surveillance for Patient Monitoring

    Directory of Open Access Journals (Sweden)

    An Braeken

    2016-01-01

    Full Text Available Video surveillance is widely deployed for many kinds of monitoring applications in healthcare and assisted living systems. Security and privacy are two promising factors that align the quality and validity of video surveillance systems with the caliber of patient monitoring applications. In this paper, we propose a symmetric key-based security framework for the reactive video surveillance of patients based on the inputs coming from data measured by a wireless body area network attached to the human body. Only authenticated patients are able to activate the video cameras, whereas the patient and authorized people can consult the video data. User and location privacy are at each moment guaranteed for the patient. A tradeoff between security and quality of service is defined in order to ensure that the surveillance system gets activated even in emergency situations. In addition, the solution includes resistance against tampering with the device on the patient’s side.

  7. Health Care Quality: Measuring Obesity in Performance Frameworks.

    Science.gov (United States)

    Zvenyach, Tracy; Pickering, Matthew K

    2017-08-01

    Obesity affects over one-third of Americans and leads to several chronic and costly comorbid conditions. The national movement toward value-based care calls for a refocusing of efforts to address the US obesity epidemic. To help set the stage, the current landscape of obesity-specific quality measures was evaluated. Seven quality measure databases and nine professional societies were searched. Inclusion and exclusion criteria were applied. Measures were then classified by domain and by implementation in national public programs. Eleven obesity-specific quality measures in adults were identified (nine process and two outcome). Three measures received National Quality Forum (NQF) endorsement. Two measures were actively used within Centers for Medicare and Medicaid Services (CMS) programs. Only one measure was both NQF-endorsed and used by CMS. Limitations exist with respect to obesity-specific quality metrics. Such gaps provide opportunities for obesity care specialists to engage and offer valuable insights and pragmatic approaches toward quality measurement. © 2017 The Obesity Society.

  8. More quality measures versus measuring what matters: a call for balance and parsimony.

    Science.gov (United States)

    Meyer, Gregg S; Nelson, Eugene C; Pryor, David B; James, Brent; Swensen, Stephen J; Kaplan, Gary S; Weissberg, Jed I; Bisognano, Maureen; Yates, Gary R; Hunt, Gordon C

    2012-11-01

    External groups requiring measures now include public and private payers, regulators, accreditors and others that certify performance levels for consumers, patients and payers. Although benefits have accrued from the growth in quality measurement, the recent explosion in the number of measures threatens to shift resources from improving quality to cover a plethora of quality-performance metrics that may have a limited impact on the things that patients and payers want and need (ie, better outcomes, better care, and lower per capita costs). Here we propose a policy that quality measurement should be: balanced to meet the need of end users to judge quality and cost performance and the need of providers to continuously improve the quality, outcomes and costs of their services; and parsimonious to measure quality, outcomes and costs with appropriate metrics that are selected based on end-user needs.

  9. Subjective Quality Measurement of Speech Its Evaluation, Estimation and Applications

    CERN Document Server

    Kondo, Kazuhiro

    2012-01-01

    It is becoming crucial to accurately estimate and monitor speech quality in various ambient environments to guarantee high quality speech communication. This practical hands-on book shows speech intelligibility measurement methods so that the readers can start measuring or estimating speech intelligibility of their own system. The book also introduces subjective and objective speech quality measures, and describes in detail speech intelligibility measurement methods. It introduces a diagnostic rhyme test which uses rhyming word-pairs, and includes: An investigation into the effect of word familiarity on speech intelligibility. Speech intelligibility measurement of localized speech in virtual 3-D acoustic space using the rhyme test. Estimation of speech intelligibility using objective measures, including the ITU standard PESQ measures, and automatic speech recognizers.

  10. The effects of video observation of chewing during lunch on masticatory ability, food intake, cognition, activities of daily living, depression, and quality of life in older adults with dementia: a study protocol of an adjusted randomized controlled trial.

    Science.gov (United States)

    Douma, Johanna G; Volkers, Karin M; Vuijk, Pieter Jelle; Scherder, Erik J A

    2016-02-04

    Masticatory functioning alters with age. However, mastication has been found to be related to, for example, cognitive functioning, food intake, and some aspects of activities of daily living. Since cognitive functioning and activities of daily living show a decline in older adults with dementia, improving masticatory functioning may be of relevance to them. A possible way to improve mastication may be showing videos of people who are chewing. Observing chewing movements may activate the mirror neuron system, which becomes also activated during the execution of that same movement. The primary hypothesis is that the observation of chewing has a beneficial effect on masticatory functioning, or, more specifically, masticatory ability of older adults with dementia. Secondary, the intervention is hypothesized to have beneficial effects on food intake, cognition, activities of daily living, depression, and quality of life. An adjusted parallel randomized controlled trial is being performed in dining rooms of residential care settings. Older adults with dementia, for whom also additional eligibility criteria apply, are randomly assigned to the experimental (videos of chewing people) or control condition (videos of nature and buildings), by drawing folded pieces of paper. Participants who are able to watch each other's videos are assigned to the same study condition. The intervention takes place during lunchtime, from Monday to Friday, for 3 months. During four moments of measurement, masticatory ability, food intake, cognitive functioning, activities of daily living, depression, and quality of life are assessed. Tests administrators blind to the group allocation administer the tests to participants. The goal of this study is to examine the effects of video observation of chewing on masticatory ability and several secondary outcome measures. In this study, the observation of chewing is added to the execution of the same action (i.e., during eating). Beneficial effects on

  11. DUQuE quality management measures: associations between quality management at hospital and pathway levels

    NARCIS (Netherlands)

    Wagner, C.; Groene, O.; Thompson, C.A.; DerSarkissian, M.; Klazinga, N.S.; Arah, O.A.; Sunol, R.

    2014-01-01

    Objective. The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were

  12. DUQuE quality management measures: associations between quality management at hospital and pathway levels

    NARCIS (Netherlands)

    Wagner, Cordula; Groene, Oliver; Thompson, Caroline A.; Dersarkissian, Maral; Klazinga, Niek S.; Arah, Onyebuchi A.; Suñol, Rosa; Kringos, D. S.; Lombarts, K.; Plochg, T.; Lopez, M. A.; Secanell, M.; Sunol, R.; Vallejo, P.; Bartels, P.; Kristensen, S.; Michel, P.; Saillour-Glenisson, F.; Vlcek, F.; Car, M.; Jones, S.; Klaus, E.; Garel, P.; Hanslik, K.; Saluvan, M.; Bruneau, C.; Depaigne-Loth, A.; Shaw, C.; Hammer, A.; Ommen, O.; Pfaff, H.; Groene, O.; Botje, D.; Wagner, C.; Kutaj-Wasikowska, H.; Kutryba, B.; Escoval, A.; Franca, M.; Almeman, F.; Kus, H.; Ozturk, K.; Mannion, R.; Chow, A.; Dersarkissian, M.; Thompson, C.; Wang, A.; Thompson, A.

    2014-01-01

    The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were developed. This

  13. DUQuE quality management measures: associations between quality management at hospital and pathway levels.

    NARCIS (Netherlands)

    Wagner, C.; Groene, O.; Thompson, C.A.; DerSarkissian, M.; Klazinga, N.S.; Arah, O.A.; Suñol, R.

    2014-01-01

    Objective: The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were

  14. Measuring the Quality of Publications : New Methodology and Case Study

    NARCIS (Netherlands)

    Kleijnen, J.P.C.; van Groenendaal, W.J.H.

    2000-01-01

    n practice, it is important to evaluate the quality of research, in order to make decisions on tenure, funding, and so on. This article develops a methodology using citations to measure the quality of journals, proceedings, and book publishers. (Citations are also used by the Science and Social

  15. Comparing Alternative Instruments to Measure Service Quality in Higher Education

    Science.gov (United States)

    Brochado, Ana

    2009-01-01

    Purpose: The purpose of this paper is to examine the performance of five alternative measures of service quality in the high education sector--service quality (SERVQUAL), importance-weighted SERVQUAL, service performance (SERVPERF), importance-weighted SERVPERF, and higher education performance (HEdPERF). Design/methodology/approach: Data were…

  16. The exploration of service quality and its measurement for private ...

    African Journals Online (AJOL)

    Kirstam

    2014-09-01

    Sep 1, 2014 ... 7The strategic importance of service excellence for service industries places the focus ... need for service quality management and measurement at PHEIs, and ... financial services, hospitality (tourism), human services, ... 1The focus of this paper was to gain insight into service quality concepts and the need.

  17. Measuring Customer Satisfaction and Quality of Service in Special Libraries.

    Science.gov (United States)

    White, Marilyn Domas; Abels, Eileen G.; Nitecki, Danuta

    This project tested the appropriateness of SERVQUAL (i.e., an instrument widely used in the service industry for assessing service quality based on repeated service encounters rather than a particular service encounter) to measure service quality in special libraries and developed a modified version for special libraries. SERVQUAL is based on an…

  18. A measuring instrument for evaluation of quality systems.

    NARCIS (Netherlands)

    Wagner, C.; Bakker, D.H. de; Groenewegen, P.P.

    1999-01-01

    Objective: To develop an instrument for provider organizations, consumers, purchasers, and policy makers to measure and compare the development of quality systems in provider organizations. Design: Cross-sectional study of provider organizations using a structured questionnaire to survey managers.

  19. 2014 Child and Adult Health Care Quality Measures

    Data.gov (United States)

    U.S. Department of Health & Human Services — Performance rates on frequently reported health care quality measures in the CMS Medicaid/CHIP Child and Adult Core Sets, for FFY 2014 reporting. Dataset contains...

  20. An evaluation of professional quality measurement systems for the ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... An evaluation of professional quality measurement systems for the automotive industry ... The ultimate goal of this study is to get comparable quantitative information about ...

  1. 2016 Child and Adult Health Care Quality Measures

    Data.gov (United States)

    U.S. Department of Health & Human Services — Performance rates on frequently reported health care quality measures in the CMS Medicaid/CHIP Child and Adult Core Sets, for FFY 2016 reporting. Source: Mathematica...

  2. Multivariate Methods Based Soft Measurement for Wine Quality Evaluation

    Directory of Open Access Journals (Sweden)

    Shen Yin

    2014-01-01

    a decision. However, since the physicochemical indexes of wine can to some extent reflect the quality of wine, the multivariate statistical methods based soft measure can help the oenologist in wine evaluation.

  3. Image quality measurements for X-ray television chains

    International Nuclear Information System (INIS)

    Mohr, M.

    1986-01-01

    Image quality measurements were carried out for 36 television chains during 3 years. For the parameters sensitivity, resolution, contrast-detail diagram, minimal contrast and dose rate average values and experiences on their long-term stability are reported. (author)

  4. 2015 Child and Adult Health Care Quality Measures

    Data.gov (United States)

    U.S. Department of Health & Human Services — Performance rates on frequently reported health care quality measures in the CMS Medicaid/CHIP Child and Adult Core Sets, for FFY 2015 reporting. Source: Mathematica...

  5. Video demystified

    CERN Document Server

    Jack, Keith

    2004-01-01

    This international bestseller and essential reference is the "bible" for digital video engineers and programmers worldwide. This is by far the most informative analog and digital video reference available, includes the hottest new trends and cutting-edge developments in the field. Video Demystified, Fourth Edition is a "one stop" reference guide for the various digital video technologies. The fourth edition is completely updated with all new chapters on MPEG-4, H.264, SDTV/HDTV, ATSC/DVB, and Streaming Video (Video over DSL, Ethernet, etc.), as well as discussions of the latest standards throughout. The accompanying CD-ROM is updated to include a unique set of video test files in the newest formats. *This essential reference is the "bible" for digital video engineers and programmers worldwide *Contains all new chapters on MPEG-4, H.264, SDTV/HDTV, ATSC/DVB, and Streaming Video *Completely revised with all the latest and most up-to-date industry standards.

  6. Measuring Beam Quality of Hollow Core Photonic Crystal Fibers

    DEFF Research Database (Denmark)

    Shephard, J.D.; Roberts, John; Jones, J.D.C.

    2006-01-01

    In this paper, the authors measure the quality of the delivered beam from hollow core photonic crystal fibers (HC-PCFs). The$M^2$parameter is determined, and the near- to far-field transition is examined. The influence on these properties due to the presence of a core surround mode is evaluated.......17 for the same output beam. This highlights the need for careful consideration when measuring and describing the beam quality delivered by these novel photonic fibers....

  7. Video Toroid Cavity Imager

    Energy Technology Data Exchange (ETDEWEB)

    Gerald, Rex E. II; Sanchez, Jairo; Rathke, Jerome W.

    2004-08-10

    A video toroid cavity imager for in situ measurement of electrochemical properties of an electrolytic material sample includes a cylindrical toroid cavity resonator containing the sample and employs NMR and video imaging for providing high-resolution spectral and visual information of molecular characteristics of the sample on a real-time basis. A large magnetic field is applied to the sample under controlled temperature and pressure conditions to simultaneously provide NMR spectroscopy and video imaging capabilities for investigating electrochemical transformations of materials or the evolution of long-range molecular aggregation during cooling of hydrocarbon melts. The video toroid cavity imager includes a miniature commercial video camera with an adjustable lens, a modified compression coin cell imager with a fiat circular principal detector element, and a sample mounted on a transparent circular glass disk, and provides NMR information as well as a video image of a sample, such as a polymer film, with micrometer resolution.

  8. Does Input Quality Drive Measured Differences in Firm Productivity?

    DEFF Research Database (Denmark)

    Fox, Jeremy T.; Smeets, Valerie Anne Rolande

    is roughly of the same order of magnitude as some competitive effects found in the literature, but input quality measures do not explain most productivity dispersion, despite economically large production function coefficients. We find that the wage bill explains as much dispersion as human capital measures.......Firms in the same industry can differ in measured productivity by multiples of 3. Griliches (1957) suggests one explanation: the quality of inputs differs across firms. We add labor market history variables such as experience and firm and industry tenure, as well as general human capital measures...

  9. Video pedagogy

    OpenAIRE

    Länsitie, Janne; Stevenson, Blair; Männistö, Riku; Karjalainen, Tommi; Karjalainen, Asko

    2016-01-01

    The short film is an introduction to the concept of video pedagogy. The five categories of video pedagogy further elaborate how videos can be used as a part of instruction and learning process. Most pedagogical videos represent more than one category. A video itself doesn’t necessarily define the category – the ways in which the video is used as a part of pedagogical script are more defining factors. What five categories did you find? Did you agree with the categories, or are more...

  10. Research and Implementation of Software Used for the Remote Control for VM700T Video Measuring Instrument

    Directory of Open Access Journals (Sweden)

    Song Wenjie

    2015-01-01

    Full Text Available In this paper, the measurement software which can be used to realize remote control of the VM700T video measuring instrument is introduced. The authors can operate VM700T by a virtual panel on the client computer, select the results that the measuring equipment displayed to transmit it, and then display the image on the VM700T virtual panel in real time. The system does have some practical values and play an important role in distance learning. The functions that the system realized mainly includes four aspects: the real-time transmission of message based on the socket technology, the serial connection between server PC and VM700T measuring equipment, the image acquisition based on VFW technology and JPEG compression and decompression, and the network transmission of image files. The actual network transmission test is shown that the data acquisition method of this thesis is flexible and convenient, and the system is of extraordinary stability. It can display the measurement results in real time and basically realize the requirements of remote control. In the content, this paper includes a summary of principle, the detailed introduction of the system realization process and some related technology.

  11. Quality measurement affecting surgical practice: Utility versus utopia.

    Science.gov (United States)

    Henry, Leonard R; von Holzen, Urs W; Minarich, Michael J; Hardy, Ashley N; Beachy, Wilbur A; Franger, M Susan; Schwarz, Roderich E

    2018-03-01

    The Triple Aim: improving healthcare quality, cost and patient experience has resulted in massive healthcare "quality" measurement. For many surgeons the origins, intent and strengths of this measurement barrage seems nebulous-though their shortcomings are noticeable. This article reviews the major organizations and programs (namely the Centers for Medicare and Medicaid Services) driving the somewhat burdensome healthcare quality climate. The success of this top-down approach is mixed, and far from convincing. We contend that the current programs disproportionately reflect the definitions of quality from (and the interests of) the national payer perspective; rather than a more balanced representation of all stakeholders interests-most importantly, patients' beneficence. The result is an environment more like performance management than one of valid quality assessment. Suggestions for a more meaningful construction of surgical quality measurement are offered, as well as a strategy to describe surgical quality from all of the stakeholders' perspectives. Our hope is to entice surgeons to engage in institution level quality improvement initiatives that promise utility and are less utopian than what is currently present. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Standard guide for making quality nondestructive assay measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This guide is a compendium of Quality Measurement Practices for performing measurements of radioactive material using nondestructive assay (NDA) instruments. The primary purpose of the guide is to assist users in arriving at quality NDA results, that is, results that satisfy the end user’s needs. This is accomplished by providing an acceptable and uniform basis for the collection, analysis, comparison, and application of data. The recommendations are not compulsory or prerequisites to achieving quality NDA measurements, but are considered contributory in most areas. 1.2 This guide applies to the use of NDA instrumentation for the measurement of nuclear materials by the observation of spontaneous or stimulated nuclear radiations, including photons, neutrons, or the flow of heat. Recommended calibration, operating, and assurance methods represent guiding principles based on current NDA technology. The diversity of industry-wide nuclear materials measurement applications and instrumentation precludes disc...

  13. VideoSET: Video Summary Evaluation through Text

    OpenAIRE

    Yeung, Serena; Fathi, Alireza; Fei-Fei, Li

    2014-01-01

    In this paper we present VideoSET, a method for Video Summary Evaluation through Text that can evaluate how well a video summary is able to retain the semantic information contained in its original video. We observe that semantics is most easily expressed in words, and develop a text-based approach for the evaluation. Given a video summary, a text representation of the video summary is first generated, and an NLP-based metric is then used to measure its semantic distance to ground-truth text ...

  14. 77 FR 42738 - Request for Information on Quality Measurement Enabled by Health IT

    Science.gov (United States)

    2012-07-20

    ... Information on Quality Measurement Enabled by Health IT AGENCY: Agency for Healthcare Research and Quality... diversified stakeholders (health information technology (IT) system developers, including vendors; payers... strategies and challenges regarding quality measurement enabled by health IT. Quality measurement--the...

  15. Measuring the quality of health care: state of the art.

    Science.gov (United States)

    Donaldson, M S; Nolan, K

    1997-05-01

    September 12-13, 1996, in Washington, DC, the Institute of Medicine, as part of its Special Initiative on Health Care Quality, held an invitational conference to illustrate exemplary quality measurement and to discuss the results. Patient reports, innovative uses of outcome measures for quality improvement, risk adjustment, assessment in integrated health plans and health care settings, clinical guidelines, and projects on disseminating information on quality measurement techniques and tools were among the topics represented. Brent James described studies undertaken to reduce adverse drug events (ADEs). When implementing any measurement system where error is a possible factor, it is important to emphasize identifying problems for the purpose of learning, not judgment. Lucian Leape agreed that staff involved must feel that the purpose of the study is to examine system problems, not individuals' mistakes. David Classen described a nonproprietary computerized disease-management program designed to reduce ADEs in infectious diseases. "A QUALITY VISION": Robert Brook said that the relationship between cost or resources devoted to care and quality is not well understood and is certainly not simple. He also said that although investments in measurement strategies are needed to make them better, that doesn't mean we shouldn't attempt to use the measurements we have now. Mark Chassin said that the presentations at the conference provided evidence that should allow us to conclude beyond a reasonable doubt that quality can be measured-with a degree of scientific precision equal to that of most of the measures used to take care of patients every day.

  16. Measures and Indicators of Vgi Quality: AN Overview

    Science.gov (United States)

    Antoniou, V.; Skopeliti, A.

    2015-08-01

    The evaluation of VGI quality has been a very interesting and popular issue amongst academics and researchers. Various metrics and indicators have been proposed for evaluating VGI quality elements. Various efforts have focused on the use of well-established methodologies for the evaluation of VGI quality elements against authoritative data. In this paper, a number of research papers have been reviewed and summarized in a detailed report on measures for each spatial data quality element. Emphasis is given on the methodology followed and the data used in order to assess and evaluate the quality of the VGI datasets. However, as the use of authoritative data is not always possible many researchers have turned their focus on the analysis of new quality indicators that can function as proxies for the understanding of VGI quality. In this paper, the difficulties in using authoritative datasets are briefly presented and new proposed quality indicators are discussed, as recorded through the literature review. We classify theses new indicators in four main categories that relate with: i) data, ii) demographics, iii) socio-economic situation and iv) contributors. This paper presents a dense, yet comprehensive overview of the research on this field and provides the basis for the ongoing academic effort to create a practical quality evaluation method through the use of appropriate quality indicators.

  17. MEASURES AND INDICATORS OF VGI QUALITY: AN OVERVIEW

    Directory of Open Access Journals (Sweden)

    V. Antoniou

    2015-08-01

    Full Text Available The evaluation of VGI quality has been a very interesting and popular issue amongst academics and researchers. Various metrics and indicators have been proposed for evaluating VGI quality elements. Various efforts have focused on the use of well-established methodologies for the evaluation of VGI quality elements against authoritative data. In this paper, a number of research papers have been reviewed and summarized in a detailed report on measures for each spatial data quality element. Emphasis is given on the methodology followed and the data used in order to assess and evaluate the quality of the VGI datasets. However, as the use of authoritative data is not always possible many researchers have turned their focus on the analysis of new quality indicators that can function as proxies for the understanding of VGI quality. In this paper, the difficulties in using authoritative datasets are briefly presented and new proposed quality indicators are discussed, as recorded through the literature review. We classify theses new indicators in four main categories that relate with: i data, ii demographics, iii socio-economic situation and iv contributors. This paper presents a dense, yet comprehensive overview of the research on this field and provides the basis for the ongoing academic effort to create a practical quality evaluation method through the use of appropriate quality indicators.

  18. Intelligent control for scalable video processing

    NARCIS (Netherlands)

    Wüst, C.C.

    2006-01-01

    In this thesis we study a problem related to cost-effective video processing in software by consumer electronics devices, such as digital TVs. Video processing is the task of transforming an input video signal into an output video signal, for example to improve the quality of the signal. This

  19. Video enhancement : content classification and model selection

    NARCIS (Netherlands)

    Hu, H.

    2010-01-01

    The purpose of video enhancement is to improve the subjective picture quality. The field of video enhancement includes a broad category of research topics, such as removing noise in the video, highlighting some specified features and improving the appearance or visibility of the video content. The

  20. Statistical method for quality control in presence of measurement errors

    International Nuclear Information System (INIS)

    Lauer-Peccoud, M.R.

    1998-01-01

    In a quality inspection of a set of items where the measurements of values of a quality characteristic of the item are contaminated by random errors, one can take wrong decisions which are damageable to the quality. So of is important to control the risks in such a way that a final quality level is insured. We consider that an item is defective or not if the value G of its quality characteristic is larger or smaller than a given level g. We assume that, due to the lack of precision of the measurement instrument, the measurement M of this characteristic is expressed by ∫ (G) + ξ where f is an increasing function such that the value ∫ (g 0 ) is known and ξ is a random error with mean zero and given variance. First we study the problem of the determination of a critical measure m such that a specified quality target is reached after the classification of a lot of items where each item is accepted or rejected depending on whether its measurement is smaller or greater than m. Then we analyse the problem of testing the global quality of a lot from the measurements for a example of items taken from the lot. For these two kinds of problems and for different quality targets, we propose solutions emphasizing on the case where the function ∫ is linear and the error ξ and the variable G are Gaussian. Simulation results allow to appreciate the efficiency of the different considered control procedures and their robustness with respect to deviations from the assumptions used in the theoretical derivations. (author)

  1. The PIT: SToPP Trial—A Feasibility Randomised Controlled Trial of Home-Based Physiotherapy for People with Parkinson's Disease Using Video-Based Measures to Preserve Assessor Blinding

    Directory of Open Access Journals (Sweden)

    Emma Stack

    2012-01-01

    Full Text Available Purpose. To trial four-week's physiotherapy targeting chair transfers for people with Parkinson's disease (PwPD and explore the feasibility of reliance on remote outcome measurement to preserve blinding. Scope. We recruited 47 PwPD and randomised 24 to a focused home physiotherapy programme (exercise, movement strategies, and cueing and 23 to a control group. We evaluated transfers (plus mobility, balance, posture, and quality of life before and after treatment and at followup (weeks 0, 4, 8, and 12 from video produced by, and questionnaires distributed by, treating physiotherapists. Participants fed back via end-of-study questionnaires. Thirty-five participants (74% completed the trial. Excluding dropouts, 20% of questionnaire data and 9% of video data were missing or unusable; we had to evaluate balance in situ. We noted trends to improvement in transfers, mobility, and balance in the physiotherapy group not noted in the control group. Participant feedback was largely positive and assessor blinding was maintained in every case. Conclusions. Intense, focused physiotherapy at home appears acceptable and likely to bring positive change in those who can participate. Remote outcome measurement was successful; questionnaire followup and further training in video production would reduce missing data. We advocate a fully powered trial, designed to minimise dropouts and preserve assessor blinding, to evaluate this intervention.

  2. Measuring Inpatient Rehabilitation Facility Quality of Care: Discharge Self-Care Functional Status Quality Measure.

    Science.gov (United States)

    Pardasaney, Poonam K; Deutsch, Anne; Iriondo-Perez, Jeniffer; Ingber, Melvin J; McMullen, Tara

    2018-06-01

    To describe the calculation and psychometric properties of the discharge self-care functional status quality measure implemented in the Centers for Medicare & Medicaid Services' (CMS) Inpatient Rehabilitation Facility (IRF) Quality Reporting Program on October 1, 2016. Medicare fee-for-service (FFS) patients from 38 IRFs that participated in the CMS Post-Acute Care Payment Reform Demonstration were included in this cohort study. Data came from the Continuity Assessment Record and Evaluation Item Set, IRF-Patient Assessment Instrument, and Medicare claims. For each patient, we calculated an expected discharge self-care score, risk-adjusted for demographic and baseline clinical characteristics. The performance score of each IRF equaled the percentage of patient stays where the observed discharge self-care score met or exceeded the expected score. We assessed the measure's discriminatory ability across IRFs and reliability. IRFs. Medicare FFS patients aged ≥21 years (N=4769). Not applicable. Facility-level discharge self-care quality measure performance score. A total of 4769 patient stays were included; 57% of stays were in women, and 12.1% were in patients aged quality measure showed strong reliability, with intraclass correlation coefficients of .91. The discharge self-care quality measure showed strong discriminatory ability and reliability, representing an important initial step in evaluation of IRF self-care outcomes. A wide range in performance scores suggested a gap in quality of care across IRFs. Future work should include testing the measure with nationwide data from all IRFs. Published by Elsevier Inc.

  3. Measuring Sandy Bottom Dynamics by Exploiting Depth from Stereo Video Sequences

    DEFF Research Database (Denmark)

    Musumeci, Rosaria E.; Farinella, Giovanni M.; Foti, Enrico

    2013-01-01

    In this paper an imaging system for measuring sandy bottom dynamics is proposed. The system exploits stereo sequences and projected laser beams to build the 3D shape of the sandy bottom during time. The reconstruction is used by experts of the field to perform accurate measurements and analysis...

  4. DUQuE quality management measures: associations between quality management at hospital and pathway levels.

    Science.gov (United States)

    Wagner, Cordula; Groene, Oliver; Thompson, Caroline A; Dersarkissian, Maral; Klazinga, Niek S; Arah, Onyebuchi A; Suñol, Rosa

    2014-04-01

    The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were developed. This study investigates the relationships between the various quality measures. It is a multi-level, cross-sectional, mixed-method study. As part of the DUQuE project, we invited a random sample of 74 hospitals in 7 countries. The quality managers of these hospitals were the main respondents. Furthermore, data of site visits of external surveyors assessing the participating hospitals were used. Three measures of QM at hospitals level focusing on integral systems (QMSI), compliance with the Plan-Do-Study-Act quality improvement cycle (QMCI) and implementation of clinical quality (CQII). Four measures of QM activities at care pathway level focusing on Specialized expertise and responsibility (SER), Evidence-based organization of pathways (EBOP), Patient safety strategies (PSS) and Clinical review (CR). Positive significant associations were found between the three hospitals level QM measures. Results of the relationships between levels were mixed and showed most associations between QMCI and department-level QM measures for all four types of departments. QMSI was associated with PSS in all types of departments. By using the seven measures of QM, it is possible to get a more comprehensive picture of the maturity of QM in hospitals, with regard to the different levels and across various types of hospital departments.

  5. Comparison of quality of life measures in a depressed population.

    Science.gov (United States)

    Wisniewski, Stephen R; Rush, A John; Bryan, Charlene; Shelton, Richard; Trivedi, Madhukar H; Marcus, Sheila; Husain, Mustafa M; Hollon, Steven D; Fava, Maurizio

    2007-03-01

    Measures of quality of life have been increasingly used in clinical trials. When designing a study, researchers must decide which quality of life measure to use. Some literature provides guidance through general recommendations, though lacks quantitative comparisons. In this report, 2 general quality of life measures, the 12-Item Short Form Health Survey (SF-12) and the Quality of Life Enjoyment and Satisfaction Questionnaire (Q-LES-Q), are compared in a depressed population. STAR*D data were used to analyze the associations among the SF-12 and the Q-LES-Q. Each measure covers 6 domains, overlapping on 5 (health, self-esteem/well-being, community/productivity, social/love relationships, leisure/creativity), with the SF-12 addressing family and the Q-LES-Q addressing living situations. Strong item-by-item associations exist only between the Q-LES-Q and the SF-12 physical health items. The 2 measures overlap on the domains covered while the lack of correlation between the 2 measures may be attributed to the perspective of each question as the Q-LES-Q measures satisfaction while the SF-12 measures the patient's perception of function.

  6. The Relationship Between Engagement and Neurophysiological Measures of Attention in Motion-Controlled Video Games: A Randomized Controlled Trial.

    Science.gov (United States)

    Leiker, Amber M; Miller, Matthew; Brewer, Lauren; Nelson, Monica; Siow, Maria; Lohse, Keith

    2016-04-21

    Video games and virtual environments continue to be the subject of research in health sciences for their capacity to augment practice through user engagement. Creating game mechanics that increase user engagement may have indirect benefits on learning (ie, engaged learners are likely to practice more) and may also have direct benefits on learning (ie, for a fixed amount of practice, engaged learners show superior retention of information or skills). To manipulate engagement through the aesthetic features of a motion-controlled video game and measure engagement's influence on learning. A group of 40 right-handed participants played the game under two different conditions (game condition or sterile condition). The mechanics of the game and the amount of practice were constant. During practice, event-related potentials (ERPs) to task-irrelevant probe tones were recorded during practice as an index of participants' attentional reserve. Participants returned for retention and transfer testing one week later. Although both groups improved in the task, there was no difference in the amount of learning between the game and sterile groups, countering previous research. A new finding was a statistically significant relationship between self-reported engagement and the amplitude of the early-P3a (eP3a) component of the ERP waveform, such that participants who reported higher levels of engagement showed a smaller eP3a (beta=-.08, P=.02). This finding provides physiological data showing that engagement elicits increased information processing (reducing attentional reserve), which yields new insight into engagement and its underlying neurophysiological properties. Future studies may objectively index engagement by quantifying ERPs (specifically the eP3a) to task-irrelevant probes.

  7. Evaluation of Human Prehension Using Grasp Quality Measures

    Directory of Open Access Journals (Sweden)

    Beatriz León

    2012-10-01

    Full Text Available One of the main features of the human hand is its grasping ability. Robot grasping has been studied for years and different quality measures have been proposed to evaluate the stability and manipulability of grasps. Although the human hand is obviously more complex than robot hands, the methods used in robotics might be adopted to study the human grasp. The purpose of this work is to propose a set of measures that allow the evaluation of different aspects of the human grasp. The most common robotic grasp quality measures have been adapted to the evaluation of the human hand and a new quality measure – the fatigue index – is proposed in order to incorporate the biomechanical aspect into the evaluation. The minimum set of indices that allows the evaluation of the different aspects of the grasp is obtained from the analysis of a human prehension experiment.

  8. Composite measures of watershed health from a water quality perspective.

    Science.gov (United States)

    Mallya, Ganeshchandra; Hantush, Mohamed; Govindaraju, Rao S

    2018-05-15

    Water quality data at gaging stations are typically compared with established federal, state, or local water quality standards to determine if violations (concentrations of specific constituents falling outside acceptable limits) have occurred. Based on the frequency and severity of water quality violations, risk metrics such as reliability, resilience, and vulnerability (R-R-V) are computed for assessing water quality-based watershed health. In this study, a modified methodology for computing R-R-V measures is presented, and a new composite watershed health index is proposed. Risk-based assessments for different water quality parameters are carried out using identified national sampling stations within the Upper Mississippi River Basin, the Maumee River Basin, and the Ohio River Basin. The distributional properties of risk measures with respect to water quality parameters are reported. Scaling behaviors of risk measures using stream order, specifically for the watershed health (WH) index, suggest that WH values increased with stream order for suspended sediment concentration, nitrogen, and orthophosphate in the Upper Mississippi River Basin. Spatial distribution of risk measures enable identification of locations exhibiting poor watershed health with respect to the chosen numerical standard, and the role of land use characteristics within the watershed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Video measurements of fluid velocities and water levels in breaking waves

    CSIR Research Space (South Africa)

    Govender, K

    2002-01-01

    Full Text Available The cost-effective measurement of the velocity flow fields in breaking water waves, using particle and correlation image velocimetry, is described. The fluid velocities are estimated by tracking the motion of neutrally buoyant particles and aeration...

  10. Measuring the Angular Velocity of a Propeller with Video Camera Using Electronic Rolling Shutter

    Directory of Open Access Journals (Sweden)

    Yipeng Zhao

    2018-01-01

    Full Text Available Noncontact measurement for rotational motion has advantages over the traditional method which measures rotational motion by means of installing some devices on the object, such as a rotary encoder. Cameras can be employed as remote monitoring or inspecting sensors to measure the angular velocity of a propeller because of their commonplace availability, simplicity, and potentially low cost. A defect of the measurement with cameras is to process the massive data generated by cameras. In order to reduce the collected data from the camera, a camera using ERS (electronic rolling shutter is applied to measure angular velocities which are higher than the speed of the camera. The effect of rolling shutter can induce geometric distortion in the image, when the propeller rotates during capturing an image. In order to reveal the relationship between the angular velocity and the image distortion, a rotation model has been established. The proposed method was applied to measure the angular velocities of the two-blade propeller and the multiblade propeller. The experimental results showed that this method could detect the angular velocities which were higher than the camera speed, and the accuracy was acceptable.

  11. Measuring relatives’ perspectives on the quality of palliative care: the Consumer Quality Index Palliative Care.

    NARCIS (Netherlands)

    Claessen, S.J.J.; Francke, A.L.; Sixma, H.J.; Veer, A.J.E. de; Deliens, L.

    2013-01-01

    Context: A Consumer Quality Index (CQ-index) is a questionnaire assessing the actual care experiences and how important the recipient finds certain care aspects, as well as the priorities for improving quality. A CQ-index Palliative Care (CQ-index PC) for bereaved relatives was developed to measure

  12. High Dynamic Range Video

    CERN Document Server

    Myszkowski, Karol

    2008-01-01

    This book presents a complete pipeline forHDR image and video processing fromacquisition, through compression and quality evaluation, to display. At the HDR image and video acquisition stage specialized HDR sensors or multi-exposure techniques suitable for traditional cameras are discussed. Then, we present a practical solution for pixel values calibration in terms of photometric or radiometric quantities, which are required in some technically oriented applications. Also, we cover the problem of efficient image and video compression and encoding either for storage or transmission purposes, in

  13. Measuring the effect of managerial ability on earning quality

    Directory of Open Access Journals (Sweden)

    Jamal Bahri Sales

    2015-09-01

    Full Text Available This paper presents an empirical investigation to measure the effect of managerial ability on earning quality on selected firms listed on Tehran Stock Exchange over the period 2007-2013. The proposed study uses data envelopment analysis to measure the relative efficiency of selected firms where Sales is considered as output and Cost of goods (COGS, Selling, General and Administrative Expenses (SG&A, Net Property Plant and Equipment (PPE, Net operating Leases (OpsLease, Research & Development (R&D, Purchased Good will (Goodwill and Other intangible assets (OtherIntan are considered as inputs. Earning quality in this survey consists of three parts of quality of accruals, earnings and earnings forecast persistence. The results of our survey have indicated that managerial ability influences positively on earning quality.

  14. Measurement of quality in Saudi Arabian service industry

    Energy Technology Data Exchange (ETDEWEB)

    Jannadi, O.A. [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia); Al-Saggaf, H. [SCECO-East (Saudi Arabia)

    2000-10-12

    Quality problems in the service organisation are the result of the mismatch between prior expectation and perceived quality of the service. Each organisation will attempt to determine the requirements of its customers and translate these requirements into product and delivery process specifications. This paper examines a particular electric company (SCECO-East), a typical service provider in Saudi Arabia, in which service quality is a distinguishing feature of primary importance. It describes a detailed survey and analysis in the light of the model put forward by Parasuraman et al. It utilises SERVQUAL for measuring customers' perceptions of service quality. The study revealed that SCECO-East scored high in tangibles dimension but low in features of responsiveness and reliability. In addition, while the performance of SCECO-East was acceptable to all customer categories, service quality was perceived differently by various types of customers, with reinforcement and commercial customers awarding SCECO-East even lower ratings than other customers did. (Author)

  15. Application Of Quality Function Deployment (QFD) To Measure Performance

    International Nuclear Information System (INIS)

    Fazila Said; Mohd Amirul Shafiq Shafiee; Nurul Hasanah Mohd Abd Basir

    2014-01-01

    This study aims to measure service quality performance and identify critical service quality characteristics as perceived by the customers. An integrated results survey that conducted by seven service centers that certified with Quality Management System (QMS) in Nuclear Malaysia are analysed. This is followed by constructing House of Quality (HoQ) and identifying other parameters for the Quality Function Deployment (QFD) matrix. HoQ is a simple and attractive service innovation tool which can be used to directly show comprehensive information which contained the voice of customer (VOC), technical response, technical correlation and matrix relationship. This study revealed that the information's from HoQ with further discussion on planning part which can be used to assist management in knowing the overall detail information of service center achievement and recognizes the solution for unsatisfied customer through priority improvement activity to enhance the customer satisfaction in future. (author)

  16. Compression evaluation of surgery video recordings retaining diagnostic credibility (compression evaluation of surgery video)

    Science.gov (United States)

    Duplaga, M.; Leszczuk, M. I.; Papir, Z.; Przelaskowski, A.

    2008-12-01

    Wider dissemination of medical digital video libraries is affected by two correlated factors, resource effective content compression that directly influences its diagnostic credibility. It has been proved that it is possible to meet these contradictory requirements halfway for long-lasting and low motion surgery recordings at compression ratios close to 100 (bronchoscopic procedures were a case study investigated). As the main supporting assumption, it has been accepted that the content can be compressed as far as clinicians are not able to sense a loss of video diagnostic fidelity (a visually lossless compression). Different market codecs were inspected by means of the combined subjective and objective tests toward their usability in medical video libraries. Subjective tests involved a panel of clinicians who had to classify compressed bronchoscopic video content according to its quality under the bubble sort algorithm. For objective tests, two metrics (hybrid vector measure and hosaka Plots) were calculated frame by frame and averaged over a whole sequence.

  17. Contactless measurement of muscles fatigue by tracking facial feature points in a video

    DEFF Research Database (Denmark)

    Irani, Ramin; Nasrollahi, Kamal; Moeslund, Thomas B.

    2014-01-01

    their exercises when the level of the fatigue might be dangerous for the patients. The current technology for measuring tiredness, like Electromyography (EMG), requires installing some sensors on the body. In some applications, like remote patient monitoring, this however might not be possible. To deal...... with such cases, in this paper we present a contactless method based on computer vision techniques to measure tiredness by detecting, tracking, and analyzing some facial feature points during the exercise. Experimental results on several test subjects and comparing them against ground truth data show...... that the proposed system can properly find the temporal point of tiredness of the muscles when the test subjects are doing physical exercises....

  18. Quality assurance measures for spent fuel shipping and storage containers

    International Nuclear Information System (INIS)

    Droste, B.; Roedel, R.

    1987-01-01

    Quality assurance measures are to be applied in production and operation to ensure the approved fuel-element-container design specifications. The authors concentrate on the official regulations pertaining to the application of a quality assurance system, on the compliance with design specifications ensured by certified manufacturing tests and in-service inspections. For nodular-cast-iron container bodies, the authors demonstrate the procedure by presenting the contents of the materials data sheet characterizing the material, and the production and test sequence plan for container casting. In addition, they state the quality assurance requirements for interim-storage containers which transgress those stipulated for shipping containers. (orig.) [de

  19. Measurement system as a subsystem of the quality management system

    Directory of Open Access Journals (Sweden)

    Ľubica Floreková

    2006-12-01

    Full Text Available Each measurement system and a control principle must be based on certain facts about the system behaviour (what, operation (how and structure (why. Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirements defines the measurement, analysis and improvement for each organization in order to present the products conformity, the quality management system conformity guarantee and for the continuously permanent improvement of effectivity, efficiency and economy of quality management system.

  20. Measuring up: Implementing a dental quality measure in the electronic health record context.

    Science.gov (United States)

    Bhardwaj, Aarti; Ramoni, Rachel; Kalenderian, Elsbeth; Neumann, Ana; Hebballi, Nutan B; White, Joel M; McClellan, Lyle; Walji, Muhammad F

    2016-01-01

    Quality improvement requires using quality measures that can be implemented in a valid manner. Using guidelines set forth by the Meaningful Use portion of the Health Information Technology for Economic and Clinical Health Act, the authors assessed the feasibility and performance of an automated electronic Meaningful Use dental clinical quality measure to determine the percentage of children who received fluoride varnish. The authors defined how to implement the automated measure queries in a dental electronic health record. Within records identified through automated query, the authors manually reviewed a subsample to assess the performance of the query. The automated query results revealed that 71.0% of patients had fluoride varnish compared with the manual chart review results that indicated 77.6% of patients had fluoride varnish. The automated quality measure performance results indicated 90.5% sensitivity, 90.8% specificity, 96.9% positive predictive value, and 75.2% negative predictive value. The authors' findings support the feasibility of using automated dental quality measure queries in the context of sufficient structured data. Information noted only in free text rather than in structured data would require using natural language processing approaches to effectively query electronic health records. To participate in self-directed quality improvement, dental clinicians must embrace the accountability era. Commitment to quality will require enhanced documentation to support near-term automated calculation of quality measures. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  1. DEVELOPMENT OF EVALUATION OF A QUANTITATIVE VIDEO-FLUORESCENCE IMAGING SYSTEM AND FLUORESCENT TRACER FOR MEASURING TRANSFER OF PESTICIDE RESIDUES FROM SURFACES TO HANDS WITH REPEATED CONTACTS

    Science.gov (United States)

    A video imaging system and the associated quantification methods have been developed for measurement of the transfers of a fluorescent tracer from surfaces to hands. The highly fluorescent compound riboflavin (Vitamin B2), which is also water soluble and non-toxic, was chosen as...

  2. In situ measurement of ceramic vacuum chamber conductive coating quality

    International Nuclear Information System (INIS)

    Doose, C.; Harkay, K.; Kim, S.; Milton, S.

    1997-01-01

    A method for measuring the relative surface resistivity and quality of conductive coatings on ceramic vacuum chambers was developed. This method is unique in that it allows one to test the coating even after the ceramic chamber is installed in the accelerator and under vacuum; furthermore, the measurement provides a localized surface reading of the coating conductance. The method uses a magnetic probe is calibrated using the measured DC end-to-end resistance of the tube under test and by comparison to a high quality test surface. The measurement method has also been verified by comparison to high frequency impedance measurements. A detailed description, results, and sensitivity of the technique are given here

  3. Effects of Video Game Training on Behavioral and Electrophysiological Measures of Attention and Memory: Protocol for a Randomized Controlled Trial.

    Science.gov (United States)

    Ballesteros, Soledad; Mayas, Julia; Ruiz-Marquez, Eloisa; Prieto, Antonio; Toril, Pilar; Ponce de Leon, Laura; de Ceballos, Maria L; Reales Avilés, José Manuel

    2017-01-24

    Neuroplasticity-based approaches seem to offer promising ways of maintaining cognitive health in older adults and postponing the onset of cognitive decline symptoms. Although previous research suggests that training can produce transfer effects, this study was designed to overcome some limitations of previous studies by incorporating an active control group and the assessment of training expectations. The main objectives of this study are (1) to evaluate the effects of a randomized computer-based intervention consisting of training older adults with nonaction video games on brain and cognitive functions that decline with age, including attention and spatial working memory, using behavioral measures and electrophysiological recordings (event-related potentials [ERPs]) just after training and after a 6-month no-contact period; (2) to explore whether motivation, engagement, or expectations might account for possible training-related improvements; and (3) to examine whether inflammatory mechanisms assessed with noninvasive measurement of C-reactive protein in saliva impair cognitive training-induced effects. A better understanding of these mechanisms could elucidate pathways that could be targeted in the future by either behavioral or neuropsychological interventions. A single-blinded randomized controlled trial with an experimental group and an active control group, pretest, posttest, and 6-month follow-up repeated measures design is used in this study. A total of 75 cognitively healthy older adults were randomly distributed into experimental and active control groups. Participants in the experimental group received 16 1-hour training sessions with cognitive nonaction video games selected from Lumosity, a commercial brain training package. The active control group received the same number of training sessions with The Sims and SimCity, a simulation strategy game. We have recruited participants, have conducted the training protocol and pretest assessments, and are

  4. Correction of raindrop size distributions measured by Parsivel disdrometers, using a two-dimensional video disdrometer as a reference

    Directory of Open Access Journals (Sweden)

    T. H. Raupach

    2015-01-01

    Full Text Available The raindrop size distribution (DSD quantifies the microstructure of rainfall and is critical to studying precipitation processes. We present a method to improve the accuracy of DSD measurements from Parsivel (particle size and velocity disdrometers, using a two-dimensional video disdrometer (2DVD as a reference instrument. Parsivel disdrometers bin raindrops into velocity and equivolume diameter classes, but may misestimate the number of drops per class. In our correction method, drop velocities are corrected with reference to theoretical models of terminal drop velocity. We define a filter for raw disdrometer measurements to remove particles that are unlikely to be plausible raindrops. Drop concentrations are corrected such that on average the Parsivel concentrations match those recorded by a 2DVD. The correction can be trained on and applied to data from both generations of OTT Parsivel disdrometers, and indeed any disdrometer in general. The method was applied to data collected during field campaigns in Mediterranean France for a network of first- and second-generation Parsivel disdrometers, and on a first-generation Parsivel in Payerne, Switzerland. We compared the moments of the resulting DSDs to those of a collocated 2DVD, and the resulting DSD-derived rain rates to collocated rain gauges. The correction improved the accuracy of the moments of the Parsivel DSDs, and in the majority of cases the rain rate match with collocated rain gauges was improved. In addition, the correction was shown to be similar for two different climatologies, suggesting its general applicability.

  5. A comparison of the quality of image acquisition between the incident dark field and sidestream dark field video-microscopes

    NARCIS (Netherlands)

    E. Gilbert-Kawai; J. Coppel (Jonny); V. Bountziouka (Vassiliki); C. Ince (Can); D. Martin (Daniel)

    2016-01-01

    markdownabstract__Background__ The ‘Cytocam’ is a third generation video-microscope, which enables real time visualisation of the in vivo microcirculation. Based upon the principle of incident dark field (IDF) illumination, this hand held computer-controlled device was designed to address the

  6. A comparison of the quality of image acquisition between the incident dark field and sidestream dark field video-microscopes

    NARCIS (Netherlands)

    Gilbert-Kawai, Edward; Coppel, Jonny; Bountziouka, Vassiliki; Ince, Can; Martin, Daniel; Ahuja, V.; Aref-Adib, G.; Burnham, R.; Chisholm, A.; Clarke, K.; Coates, D.; Coates, M.; Cook, D.; Cox, M.; Dhillon, S.; Dougall, C.; Doyle, P.; Duncan, P.; Edsell, M.; Edwards, L.; Evans, L.; Gardiner, P.; Grocott, M.; Gunning, P.; Hart, N.; Harrington, J.; Harvey, J.; Holloway, C.; Howard, D.; Hurlbut, D.; Imray, C.; Jonas, M.; van der Kaaij, J.; Khosravi, M.; Kolfschoten, N.; Levett, D.; Luery, H.; Luks, A.; Martin, D.; McMorrow, R.; Meale, P.; Mitchell, K.; Montgomery, H.; Morgan, G.; Morgan, J.; Murray, A.; Mythen, M.; Newman, S.; O'Dwyer, M.; Pate, J.

    2016-01-01

    Background: The 'Cytocam' is a third generation video-microscope, which enables real time visualisation of the in vivo microcirculation. Based upon the principle of incident dark field (IDF) illumination, this hand held computer-controlled device was designed to address the technical limitations of

  7. Online and offline video game use in adolescents: measurement invariance and problem severity

    OpenAIRE

    Smohai, M; Urbán, R; Griffiths, MD; Király, O; Mirnics, Z; Vargha, A; Demetrovics, Z

    2017-01-01

    Background:\\ud \\ud Despite the increasing popularity of videogame playing, little is known about the similarities and differences between online and offline videogame players. However, the characteristics of online and offline gaming might predispose different pattern of problematic use.\\ud \\ud Objectives:\\ud \\ud The aims of this study were to (i) test applicability and the measurement invariance of the previously developed Problematic Online Gaming Questionnaire (POGQ) in both online and off...

  8. Use of miniature tensile specimen and video extensometer for measurement of mechanical properties

    International Nuclear Information System (INIS)

    Kumar, Kundan; Pooleery, Arun; Madhusoodanan, K.

    2014-08-01

    Miniaturisation of the tensile test specimen below the sub-size level poses various challenges, such as conformity of specimen to various acceptance criteria as per standard test specimen, aspect ratio, minimum number of grains required in a gauge cross-section, fabrication for uniformity in metrological values, etc. Apart from these, measurement of strain over a very limited available space on the test specimen is another practical challenge. Despite these limitations, miniature specimen testing is increasingly being used worldwide these days. The driving forces behind increasing use of miniature test techniques are new material development, assuring fitness of component after in-service-inspection, low dose of radiation exposure due to smaller dimensions of test specimens etc. However, the evaluation of mechanical properties from a miniature tensile test has a greater advantage over the other miniature novel test techniques, such as small punch test, ABI, miniature fatigue and impact tests etc., as it is a direct method of measurement of mechanical properties. This report covers various aspects of miniature tensile test methodologies, which include geometrical design of specimen having gauge length of 3-5 mm, fabrication, development of special fixtures for gripping the test specimens, and use of optical method for strain measurement. The geometrical design of the specimen and its behaviour over application of tensile load has been established using FEM analysis. A good agreement between conventional and miniature test results exemplifies the potential of the miniature tensile test technique. (author)

  9. Measuring frequency of one-dimensional vibration with video camera using electronic rolling shutter

    Science.gov (United States)

    Zhao, Yipeng; Liu, Jinyue; Guo, Shijie; Li, Tiejun

    2018-04-01

    Cameras offer a unique capability of collecting high density spatial data from a distant scene of interest. They can be employed as remote monitoring or inspection sensors to measure vibrating objects because of their commonplace availability, simplicity, and potentially low cost. A defect of vibrating measurement with the camera is to process the massive data generated by camera. In order to reduce the data collected from the camera, the camera using electronic rolling shutter (ERS) is applied to measure the frequency of one-dimensional vibration, whose frequency is much higher than the speed of the camera. Every row in the image captured by the ERS camera records the vibrating displacement at different times. Those displacements that form the vibration could be extracted by local analysis with sliding windows. This methodology is demonstrated on vibrating structures, a cantilever beam, and an air compressor to identify the validity of the proposed algorithm. Suggestions for applications of this methodology and challenges in real-world implementation are given at last.

  10. Measuring service life and evaluating the quality of solid tires

    Directory of Open Access Journals (Sweden)

    Charoenyut Dechwayukul

    2010-08-01

    Full Text Available The objective of this research is to propose procedures for measuring service life and evaluating the quality of locallymade and used solid tires in Thailand. The solid tires were stressed and rotated until blowout on a drum-like test apparatuswhich is designed, constructed by the authors and equipped with laboratory instrumentation. Solid tires from five differentmanufacturers were selected for testing. We measured service life, length of time to tire failure, at three different loadingamplitudes and three different speeds on the testing drum. The service life of all specimens was studied and compared todetermine the possibility of using service life to evaluate the quality of a solid tire.

  11. Student’s Video Production as Formative Assessment

    Directory of Open Access Journals (Sweden)

    Eduardo Gama

    2017-04-01

    Full Text Available Learning assessments are subject of discussion both in their theoretical and practical approaches. The process of measuring learning in physics by high school students, either qualitatively or quantitatively, is one in which it should be possible to identify not only the concepts and contents students failed to achieve but also the reasons for the failure. We propose that students’ video production offers a very effective formative assessment tool to teachers: as a formative assessment, it produces information that allows the understanding of where and when the learning process succeeded or failed, of identifying, as a subject or as a group, the deficiencies or misunderstandings related to the theme under analysis and their interpretation by students, and it provides also a different kind of assessment, related to some other life skills, such as ability to carry on a project till its conclusion and to work cooperatively. In this paper, we describe the use of videos produced by high school students as an assessment resource. The students were asked to prepare a short video, which was then presented to the whole group and discussed. The videos reveal aspects of students’ difficulties that usually do not appear in formal assessments such as tests and questionnaires. After the use of the videos as a component of classroom assessments and the use of the discussions to rethink learning activities in the group, the videos were analysed and classified in various categories. This analysis showed a strong correlation between the technical quality of the video and the content quality of the students’ argumentation. Also, it was shown that the students do not prepare their video based on quick and easy production; they usually choose forms of video production that require careful planning and implementation, and this reflects directly on the overall quality of the video and of the learning process.

  12. Measuring and improving quality in university hospitals in Canada: The Collaborative for Excellence in Healthcare Quality.

    Science.gov (United States)

    Backman, Chantal; Vanderloo, Saskia; Forster, Alan John

    2016-09-01

    Measuring and monitoring overall health system performance is complex and challenging but is crucial to improving quality of care. Today's health care organizations are increasingly being held accountable to develop and implement actions aimed at improving the quality of care, reducing costs, and achieving better patient-centered care. This paper describes the development of the Collaborative for Excellence in Healthcare Quality (CEHQ), a 5-year initiative to achieve higher quality of patient care in university hospitals across Canada. This bottom-up initiative took place between 2010 and 2015, and was successful in engaging health care leaders in the development of a common framework and set of performance measures for reporting and benchmarking, as well as working on initiatives to improve performance. Despite its successes, future efforts are needed to provide clear national leadership on standards for measuring performance. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  13. Quality improvement education to improve performance on ulcerative colitis quality measures and care processes aligned with National Quality Strategy priorities.

    Science.gov (United States)

    Greene, Laurence; Moreo, Kathleen

    2015-01-01

    Studies on inflammatory bowel disease (IBD) have reported suboptimal approaches to patient care. In the United States, the findings have motivated leading gastroenterology organizations to call for initiatives that support clinicians in aligning their practices with quality measures for IBD and priorities of the National Quality Strategy (NQS). We designed and implemented a quality improvement (QI) education program on ulcerative colitis in which patient charts were audited for 30 gastroenterologists before (n = 300 charts) and after (n = 290 charts) they participated in QI-focused educational activities. Charts were audited for nine measures, selected for their alignment with four NQS priorities: making care safer, ensuring patient engagement, promoting communication, and promoting effective treatment practices. Four of the measures, including guideline-directed vaccinations and assessments of disease type and activity, were part of the CMS Physician Quality Reporting System (PQRS). The other five measures involved counseling patients on various topics in ulcerative colitis management, documentation of side effects, assessment of adherence status, and simplification of dosing. The gastroenterologists also completed baseline and post-education surveys designed to assess qualitative outcomes. One of the educational interventions was a private audit feedback session conducted for each gastroenterologist. The sessions were designed to support participants in identifying measures reflecting suboptimal care quality and developing action plans for improvement. In continuous improvement cycles, follow-up interventions included QI tools and educational monographs. Across the nine chart variables, post-education improvements ranged from 0% to 48%, with a mean improvement of 15.9%. Survey findings revealed improvements in self-reported understanding of quality measures and intentions to apply them to practice, and lower rates of perceived significant barriers to high-quality

  14. A Refrigerated Web Camera for Photogrammetric Video Measurement inside Biomass Boilers and Combustion Analysis

    Directory of Open Access Journals (Sweden)

    Enrique Granada

    2011-01-01

    Full Text Available This paper describes a prototype instrumentation system for photogrammetric measuring of bed and ash layers, as well as for flying particle detection and pursuit using a single device (CCD web camera. The system was designed to obtain images of the combustion process in the interior of a domestic boiler. It includes a cooling system, needed because of the high temperatures in the combustion chamber of the boiler. The cooling system was designed using CFD simulations to ensure effectiveness. This method allows more complete and real-time monitoring of the combustion process taking place inside a boiler. The information gained from this system may facilitate the optimisation of boiler processes.

  15. A refrigerated web camera for photogrammetric video measurement inside biomass boilers and combustion analysis.

    Science.gov (United States)

    Porteiro, Jacobo; Riveiro, Belén; Granada, Enrique; Armesto, Julia; Eguía, Pablo; Collazo, Joaquín

    2011-01-01

    This paper describes a prototype instrumentation system for photogrammetric measuring of bed and ash layers, as well as for flying particle detection and pursuit using a single device (CCD) web camera. The system was designed to obtain images of the combustion process in the interior of a domestic boiler. It includes a cooling system, needed because of the high temperatures in the combustion chamber of the boiler. The cooling system was designed using CFD simulations to ensure effectiveness. This method allows more complete and real-time monitoring of the combustion process taking place inside a boiler. The information gained from this system may facilitate the optimisation of boiler processes.

  16. Face puzzle—two new video-based tasks for measuring explicit and implicit aspects of facial emotion recognition

    Science.gov (United States)

    Kliemann, Dorit; Rosenblau, Gabriela; Bölte, Sven; Heekeren, Hauke R.; Dziobek, Isabel

    2013-01-01

    Recognizing others' emotional states is crucial for effective social interaction. While most facial emotion recognition tasks use explicit prompts that trigger consciously controlled processing, emotional faces are almost exclusively processed implicitly in real life. Recent attempts in social cognition suggest a dual process perspective, whereby explicit and implicit processes largely operate independently. However, due to differences in methodology the direct comparison of implicit and explicit social cognition has remained a challenge. Here, we introduce a new tool to comparably measure implicit and explicit processing aspects comprising basic and complex emotions in facial expressions. We developed two video-based tasks with similar answer formats to assess performance in respective facial emotion recognition processes: Face Puzzle, implicit and explicit. To assess the tasks' sensitivity to atypical social cognition and to infer interrelationship patterns between explicit and implicit processes in typical and atypical development, we included healthy adults (NT, n = 24) and adults with autism spectrum disorder (ASD, n = 24). Item analyses yielded good reliability of the new tasks. Group-specific results indicated sensitivity to subtle social impairments in high-functioning ASD. Correlation analyses with established implicit and explicit socio-cognitive measures were further in favor of the tasks' external validity. Between group comparisons provide first hints of differential relations between implicit and explicit aspects of facial emotion recognition processes in healthy compared to ASD participants. In addition, an increased magnitude of between group differences in the implicit task was found for a speed-accuracy composite measure. The new Face Puzzle tool thus provides two new tasks to separately assess explicit and implicit social functioning, for instance, to measure subtle impairments as well as potential improvements due to social cognitive

  17. Immersive video

    Science.gov (United States)

    Moezzi, Saied; Katkere, Arun L.; Jain, Ramesh C.

    1996-03-01

    Interactive video and television viewers should have the power to control their viewing position. To make this a reality, we introduce the concept of Immersive Video, which employs computer vision and computer graphics technologies to provide remote users a sense of complete immersion when viewing an event. Immersive Video uses multiple videos of an event, captured from different perspectives, to generate a full 3D digital video of that event. That is accomplished by assimilating important information from each video stream into a comprehensive, dynamic, 3D model of the environment. Using this 3D digital video, interactive viewers can then move around the remote environment and observe the events taking place from any desired perspective. Our Immersive Video System currently provides interactive viewing and `walkthrus' of staged karate demonstrations, basketball games, dance performances, and typical campus scenes. In its full realization, Immersive Video will be a paradigm shift in visual communication which will revolutionize television and video media, and become an integral part of future telepresence and virtual reality systems.

  18. The Aeroflex: A Bicycle for Mobile Air Quality Measurements

    Science.gov (United States)

    Elen, Bart; Peters, Jan; Van Poppel, Martine; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2013-01-01

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. PMID:23262484

  19. Measuring quality of life in Macedonia - using human development indicators

    Directory of Open Access Journals (Sweden)

    Dimitar Eftimoski

    2006-12-01

    Full Text Available By the end of the 1980s, the central issue of development was focused on the growth of income and not on the growth of quality of life. Therefore, the development strategies were oriented towards production and left no significant space for improving the welfare of individuals.In the beginning of the 1990s, the human development concept emerged, stressing that economic development ultimately should result in growth of quality of life of individuals, while the goal of the development process was to expand the capabilities of individuals by placing them in the focus of the efforts for development.This paper if focused on the quality of life of the individuals. Moreover, in addition to the previous practice in Macedonia of calculating the human development index (HDI - as a measure of quality of life, an attempt will be made to calculate the humanpoverty index (HPI-2 - as a measure of non-income poverty, gender development index (GDI - as a measure of inequality between men and women, as well as the human development index at the level of aggregated urban and rural municipalities.We hope that it will contribute to the improvement of the quality of decisions made by the state and local authorities in Macedonia when it comes to issues concerning the human development.

  20. Measurement of the perceived quality of a product

    Directory of Open Access Journals (Sweden)

    Maire J.-L.

    2013-01-01

    Full Text Available For some companies, visual inspection has become an essential step when seeking to improve the quality of their products. The aim of this control is to be sure of the perceived quality of the product, which often goes well beyond the quality expected by the customer. For this type of control, the controller should be able to detect any anomaly on a product, characterize this anomaly, and then evaluate it in order to decide if the product should be accepted or rejected. This paper describes how this characterization can be carried out and, more specifically, how to measure the impact of the local environment of an anomaly on the perceived quality of the product.

  1. Measurements and prediction of inhaled air quality with personalized ventilation

    DEFF Research Database (Denmark)

    Cermak, Radim; Majer, M.; Melikov, Arsen Krikor

    2002-01-01

    the room air) at flow rates ranging from less than 5 L/s up to 23 L/s. The air quality assessment was based on temperature measurements of the inhaled air and on the portion of the personalized air inhaled. The percentage of dissatisfied with the air quality was predicted. The results suggest......This paper examines the performance of five different air terminal devices for personalized ventilation in relation to the quality of air inhaled by a breathing thermal manikin in a climate chamber. The personalized air was supplied either isothermally or non-isothermally (6 deg.C cooler than...... that regardless of the temperature combinations, personalized ventilation may decrease significantly the number of occupants dissatisfied with the air quality. Under non-isothermal conditions the percentage of dissatisfied may decrease up to 4 times....

  2. Measurement properties of asthma-specific quality-of-life measures: protocol for a systematic review.

    Science.gov (United States)

    Apfelbacher, Christian; Paudyal, Priya; Bülbül, Alpaslan; Smith, Helen

    2014-07-24

    Asthma is a frequent chronic inflammatory disease of the airways, and the assessment of health-related quality of life (HrQoL) is important in both research and routine care. Various asthma-specific measures of HrQoL exist but there is uncertainty which measures are best suited for use in research and routine care. Therefore, the aim of the proposed research is a comprehensive systematic assessment of the measurement properties of the existing measures that were developed to measure asthma-specific quality of life. This study is a systematic review of the measurement properties of asthma-specific measures of health-related quality of life. PubMed and Embase will be searched using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing or comparing measurement properties of asthma-specific HRQL tools. Eligibility assessment and data abstraction will be performed independently by two reviewers. Evidence tables will be generated for study characteristics, instrument characteristics, measurement properties and interpretability. The quality of the measurement properties will be assessed using predefined criteria. Methodological quality of studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis will be undertaken if more than one study have investigated a particular measurement property. The proposed systematic review will produce a comprehensive assessment of measurement properties of existing measures of asthma-specific health-related quality of life. We also aim to derive recommendations in order to help researchers and practitioners alike in the choice of instrument. PROSPERO registration number: CRD42014010491.

  3. Measures of quality of process models created in BPMN

    Directory of Open Access Journals (Sweden)

    Radek Hronza

    2015-12-01

    Full Text Available Description, documentation, evaluation and redesign of key processes during their execution should be an essential part of the strategic management of any organization. All organizations live in a dynamically changing environment. Therefore they must adapt its internal processes to market changes. These processes must be described. Suitable way of description could be BPMN notation. Right after description of processes via BPMN, processes should be controlled to ensure expected of their quality. System (which could be automated based on mathematical expression of qualitative characteristics of process models (i.e. measures of quality of process models can support mentioned process controls. Research team trying to design and get into practical use such a tool. The aim of this publication is description of mentioned system – based on measures of the quality of process models - and answer associated scientific questions.

  4. Results from power quality measurements in Germany - An overview

    Energy Technology Data Exchange (ETDEWEB)

    Gerdes, G.J.; Santjer, F. [German Wind Energy Inst, Wilhelmshaven (Germany)

    1996-12-31

    Grid interferences caused by wind turbines (WT) are getting a severe problem in Germany with the fast increasing number of installed turbines. The wind energy capacity was doubled annually in the past three years. The actual situation and the plannings for the next years will lead to a situation, where high wind energy penetration will exercise a big influence on the power and voltage quality of local utility networks. Measurements performed in Germany according to a national guideline show a big variety in power quality performance of WT`s, which does affect the requirements for grid connection and thus the economical situation of wind energy projects to a large extent. The results from more than 25 power quality measurements will be discussed in this paper. 5 refs., 5 figs., 1 tab.

  5. Measures to improve the quality of hotel services

    Directory of Open Access Journals (Sweden)

    Anca MADAR

    2017-07-01

    Full Text Available This article aims to exemplify how, starting from the evaluation of customer satisfaction on service quality, the hotel units’ management, can apply different measures and strategies to improve it. To achieve the target, a marketing research survey is conducted based on a sample of 120 customers of Hotel „Kronwell” at the end of 2013. After analysing customer’ responses a series of measures have been taken to improve the quality of services offered by this hotel, then at the end of 2015 a new research was achieved, based on the same questionnaire. The results of this research highlight the increasing of customer satisfaction as a result of improving the quality of hotel services, supported by growth in net profit, turnover and decrease of employees’ number.

  6. Measures of Ruleset Quality for General Rules Extraction Methods

    Czech Academy of Sciences Publication Activity Database

    Holeňa, Martin

    2009-01-01

    Roč. 50, č. 6 (2009), s. 867-879 ISSN 0888-613X R&D Projects: GA ČR GA201/08/0802 Institutional research plan: CEZ:AV0Z10300504 Keywords : rules extraction from data * quality measures * ruleset measures * ROC curves * observational logic * fuzzy logic Subject RIV: IN - Informatics, Computer Science Impact factor: 2.090, year: 2009

  7. Measurement system as a subsystem of the quality management system

    OpenAIRE

    Ľubica Floreková; Ján Terpák; Marcela Čarnogurská

    2006-01-01

    Each measurement system and a control principle must be based on certain facts about the system behaviour (what), operation (how) and structure (why). Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirem...

  8. Requirements for a quality measurement instrument for semantic standards

    NARCIS (Netherlands)

    Folmer, E.J.A.; Krukkert, D.; Oude Luttighuis, P.; Hillegersberg van, J. van

    2010-01-01

    This study describes requirements for an instrument to measure the quality of semantic standards. A situational requirements engineering method was used, resulting in a goal-tree in which requirements are structured. This structure shows requirements related to the input of the instrument; stating

  9. Quality measures for HRR alignment based ISAR imaging algorithms

    CSIR Research Space (South Africa)

    Janse van Rensburg, V

    2013-05-01

    Full Text Available Some Inverse Synthetic Aperture Radar (ISAR) algorithms form the image in a two-step process of range alignment and phase conjugation. This paper discusses a comprehensive set of measures used to quantify the quality of range alignment, with the aim...

  10. Measurement of Classroom Teaching Quality with Item Response Theory

    Science.gov (United States)

    Kelcey, Ben; McGinn, Daniel; Hill, Heather

    2013-01-01

    Recent policy has charged schools and districts with maintaining highly qualified teachers and differentiating among teachers in terms of their effectiveness (U.S. Department of Education, 2009). This emphasis has driven the development and implementation of teacher quality measures which are increasingly being used to evaluate teachers with…

  11. Standardized measurement of quality of life after incisional hernia repair

    DEFF Research Database (Denmark)

    Jensen, Kristian K; Henriksen, Nadia A; Harling, Henrik

    2014-01-01

    repair. The aim of this systematic review was to analyze existing standardized methods to measure quality of life after incisional hernia repair. DATA SOURCES: A PubMed and Embase search was carried out together with a cross-reference search of eligible papers, giving a total of 26 included studies...

  12. Improving Quality Of Spectrum Measurement By Event - Event Coincidence Technique

    International Nuclear Information System (INIS)

    Pham Dinh Khang; Doan Trong Thu; Nguyen Duc Hoa; Nguyen An Son; Nguyen Xuan Hai; Ho Huu Thang

    2011-01-01

    To improve the quality of measurement data for the research levels density and gamma strength function in intermediate energy region below the neutron binding energy (B n ), a new method was developed at the Dalat Nuclear Research Institute. This method improve the ratio of the count of peak per compton background more times. This results are evaluated, compared with other methods. (author)

  13. Measuring Quality in Special Libraries: Lessons from Service Marketing.

    Science.gov (United States)

    White, Marilyn Domas; Abels, Eileen G.

    1995-01-01

    Surveys the service marketing literature for models and data-gathering instruments measuring service quality, particularly the instruments SERVQUAL and SERVPERF, and assesses their applicability to special libraries and information centers. Topics include service characteristics and definitions of service; performance-minus-expectations and…

  14. Assessment of Rheumatoid Arthritis Quality Process Measures and Associated Costs.

    Science.gov (United States)

    Brady, Brenna L; Tkacz, Joseph; Meyer, Roxanne; Bolge, Susan C; Ruetsch, Charles

    2017-02-01

    The objective was to examine the relationship between health care costs and quality in rheumatoid arthritis (RA). Administrative claims were used to calculate 8 process measures for the treatment of RA. Associated health care costs were calculated for members who achieved or did not achieve each of the measures. Medical, pharmacy, and laboratory claims for RA patients (International Classification of Diseases, Ninth Revision, Clinical Modification 714.x) were extracted from the Optum Clinformatics Datamart database for 2011. Individuals were predominately female and in their mid-fifties. Measure achievement ranged from 55.9% to 80.8%. The mean cost of care for members meeting the measure was $18,644; members who did not meet the measures had a mean cost of $14,973. Primary cost drivers were pharmacy and office expenses, accounting for 42.4% and 26.3% of total costs, respectively. Regression analyses revealed statistically significant associations between biologic usage, which was more prevalent in groups attaining measures, and total expenditure across all measures (Ps < 0.001). Pharmacy costs were similar between both groups. Individuals meeting the measures had a higher proportion of costs accounted for by office visits; those not meeting the measures had a higher proportion of costs from inpatient and outpatient visits. These findings suggest that increased quality may lead to lower inpatient and outpatient hospital costs. Yet, the overall cost of RA care is likely to remain high because of intensive pharmacotherapy regimens.

  15. Development of a ROV Deployed Video Analysis Tool for Rapid Measurement of Submerged Oil/Gas Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Savas, Omer [Univ. of California, Berkeley, CA (United States)

    2017-04-03

    Expanded deep sea drilling around the globe makes it necessary to have readily available tools to quickly and accurately measure discharge rates from accidental submerged oil/gas leak jets for the first responders to deploy adequate resources for containment. We have developed and tested a field deployable video analysis software package which is able to provide in the field sufficiently accurate flow rate estimates for initial responders in accidental oil discharges in submarine operations. The essence of our approach is based on tracking coherent features at the interface in the near field of immiscible turbulent jets. The software package, UCB_Plume, is ready to be used by the first responders for field implementation. We have tested the tool on submerged water and oil jets which are made visible using fluorescent dyes. We have been able to estimate the discharge rate within 20% accuracy. A high end WINDOWS laptop computer is suggested as the operating platform and a USB connected high speed, high resolution monochrome camera as the imaging device are sufficient for acquiring flow images under continuous unidirectional illumination and running the software in the field. Results are obtained over a matter of minutes.

  16. The air quality in Norwegian cities. Development - reasons - measures - future

    International Nuclear Information System (INIS)

    Larssen, Steinar; Hagen, Leif Otto

    1998-12-01

    There is an increasing focus on the air quality in Norwegian cities and townships. The air quality depends on several factors and the connections are complex. The aim of this report is to present a short and simple survey of this complex field. The report consists of three parts: Part 1 is a survey of the development until today. Measurements of SO 2 and soot were started in the 1950's. Systematic determinations of NO x and NO 2 , CO and particles, ozone and benzene was started during the last three decades. The population exposure to air pollutants and their main sources are described as well as the air quality in Norwegian cities compared to other cities in Europe. In part 2 developments within transport, a sector necessary for understanding the development, are described. Part 3 is a survey of forecasting the air quality in Norway, pollution warnings and surveillance. The forecasts are based on assumed developments in important sectors such as transport, energy consumption for heating and industrial purposes and the effects of demands for fuel and vehicles. Effect analyses of further measures which may be useful for reaching the national goals for the air quality are carried out. A survey of the most important limiting values and criteria as well as technical terms is presented in the report and in the appendix. The report is commissioned by the Norwegian Petroleum Institute (Norsk Petroleumsinstitutt) and the Norwegian Road Federation (Opplysningsraadet for Veitrafikken)

  17. Measuring the quality of public open space using Google Earth.

    Science.gov (United States)

    Taylor, Bronwen T; Fernando, Peter; Bauman, Adrian E; Williamson, Anna; Craig, Jonathan C; Redman, Sally

    2011-02-01

    Proximity to public open space, such as parks and other green spaces, has considerable health benefits, and people have been shown to be more likely to use such space for physical activity if it is of high quality. This paper describes a new remote-assessment approach that makes use of Google Earth Pro (the free version of this program is Google Earth) to provide rapid and inexpensive measurement of the quality of public open space. The aim of the study was to assess the correlation between assessments of the quality of public open space using (1) the remote method (making use of Google Earth Pro) and (2) direct observation with a well-established measure of quality, the Public Open Space Tool (POST). Fifty parks selected from the southwest part of Sydney, Australia, were assessed in 2009 with the remote method (using Google Earth Pro), and scores were compared with those obtained from direct observation of the same parks using POST. The time taken to conduct the assessments using each method was also recorded. Raters for each method were blind to scores obtained from using the other method. Analyses were conducted in 2009. The Spearman correlation coefficient between the quality scores obtained for the 50 parks using the remote method and direct observation was 0.9 (pspaces without the need for in-person visits, dramatically reducing the time required for environmental audits of public open space. Copyright © 2011 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  18. MEASUREMENT OF QUALITY MANAGEMENT SYSTEM PERFORMANCE IN MEAT PROCESSING

    Directory of Open Access Journals (Sweden)

    Elena S. Voloshina

    2017-01-01

    Full Text Available Modern methods aimed to ensure the quality of foods require to implement and certify quality management systems in processing plants. In this case, to measure the effectiveness of existing QMS is often a very difficult task for the leadership due to the fragmentation of the measured metrics, or even lack thereof. This points to the relevance of the conducted research.The criteria for effectiveness assessment of the production process of meat processing plants with the use of scaling methods and Shewhart control charts are presented in the article. The authors developed and presented the formulae for the calculation of single indicators used for the further comprehensive assessment. The algorithm of statistical evaluation of the process controllability, which allows in an accessible form to estimate the statistical control of production processes and to organize statistical quality control in the development of quality management systems, is presented The proposed procedure is based on a process approach, the essence of which is the application of the Deming cycle: “Plan — Do — Check — Act”, which makes it easy to integrate it into any existing quality management system.

  19. Measuring service quality in a hospital colposcopy clinic.

    Science.gov (United States)

    Wisniewski, Mik; Wisniewski, Hazel

    2005-01-01

    The issues surrounding the measurement and provision of service quality in a health care setting are becoming increasingly important to nursing. This research study aims to apply the SERVQUAL measurement instrument in a Scottish colposcopy clinic. The study involved adapting the SERVQUAL instrument to the colposcopy setting and asking a sample of patients to complete the questionnaire. Patient expectations of service were obtained on first attendance at the clinic. Patient perceptions of service received were obtained on completion of treatment. Perceptions and expectations are then compared to identify where the largest service gaps exist. Although patient satisfaction with the overall service provided was generally high, the instrument provided evidence of where specific service improvements were needed. The largest service quality gap was for the reliability of service. The research also revealed the need for improved premises. Although the study has a limited sample size, it does appear that the SERVQUAL instrument has a useful diagnostic role to play in assessing and monitoring service quality in nursing, enabling nursing staff to identify where improvements are needed from the patients' perspective. The study has raised a number of issues which would form the basis for useful further research. Service quality from the patients' perspective should be routinely monitored and assessed. The findings should be useful to nursing staff seeking to assess, and improve, service quality.

  20. Using high-technology to enforce low-technology safety measures: the use of third-party remote video auditing and real-time feedback in healthcare.

    Science.gov (United States)

    Armellino, Donna; Hussain, Erfan; Schilling, Mary Ellen; Senicola, William; Eichorn, Ann; Dlugacz, Yosef; Farber, Bruce F

    2012-01-01

    Hand hygiene is a key measure in preventing infections. We evaluated healthcare worker (HCW) hand hygiene with the use of remote video auditing with and without feedback. The study was conducted in an 17-bed intensive care unit from June 2008 through June 2010. We placed cameras with views of every sink and hand sanitizer dispenser to record hand hygiene of HCWs. Sensors in doorways identified when an individual(s) entered/exited. When video auditors observed a HCW performing hand hygiene upon entering/exiting, they assigned a pass; if not, a fail was assigned. Hand hygiene was measured during a 16-week period of remote video auditing without feedback and a 91-week period with feedback of data. Performance feedback was continuously displayed on electronic boards mounted within the hallways, and summary reports were delivered to supervisors by electronic mail. During the 16-week prefeedback period, hand hygiene rates were less than 10% (3933/60 542) and in the 16-week postfeedback period it was 81.6% (59 627/73 080). The increase was maintained through 75 weeks at 87.9% (262 826/298 860). The data suggest that remote video auditing combined with feedback produced a significant and sustained improvement in hand hygiene.

  1. Video games

    OpenAIRE

    Kolář, Vojtěch

    2012-01-01

    This thesis is based on a detailed analysis of various topics related to the question of whether video games can be art. In the first place it analyzes the current academic discussion on this subject and confronts different opinions of both supporters and objectors of the idea, that video games can be a full-fledged art form. The second point of this paper is to analyze the properties, that are inherent to video games, in order to find the reason, why cultural elite considers video games as i...

  2. Criteria and tools for scientific software quality measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tseng, M Y [Previse Inc., Willowdale ON (Canada)

    1995-12-01

    Not all software used in the nuclear industry needs the rigorous formal verification, reliability testing and quality assessment that are being applied to safety critical software. Recently, however, there is increasing recognition that systematic and objective quality assessment of the scientific software used in design and safety analyses of nuclear facilities is necessary to support safety and licensing decisions. Because of the complexity and large size of these programs and the resource constraints faced by the AECB reviewer, it is desirable that appropriate automated tools are used wherever practical. To objectively assess the quality of software, a set of attributes of a software product by which its quality is described and evaluated must be established. These attributes must be relevant to the application domain of software under evaluation. To effectively assess the quality of software, metrics defining quantitative scale and method appropriate to determine the value of attributes need to be applied. To cost-effectively perform the evaluation, use of suitable automated tools is desirable. In this project, criteria for evaluating the quality of scientific software are presented; metrics for which those criteria can be evaluated are identified; a survey of automated tools to measure those metrics was conducted and the most appropriate tool (QA Fortran) was acquired; and the tool usage was demonstrated on three sample programs. (author) 5 refs.

  3. Criteria and tools for scientific software quality measurements

    International Nuclear Information System (INIS)

    Tseng, M.Y.

    1995-12-01

    Not all software used in the nuclear industry needs the rigorous formal verification, reliability testing and quality assessment that are being applied to safety critical software. Recently, however, there is increasing recognition that systematic and objective quality assessment of the scientific software used in design and safety analyses of nuclear facilities is necessary to support safety and licensing decisions. Because of the complexity and large size of these programs and the resource constraints faced by the AECB reviewer, it is desirable that appropriate automated tools are used wherever practical. To objectively assess the quality of software, a set of attributes of a software product by which its quality is described and evaluated must be established. These attributes must be relevant to the application domain of software under evaluation. To effectively assess the quality of software, metrics defining quantitative scale and method appropriate to determine the value of attributes need to be applied. To cost-effectively perform the evaluation, use of suitable automated tools is desirable. In this project, criteria for evaluating the quality of scientific software are presented; metrics for which those criteria can be evaluated are identified; a survey of automated tools to measure those metrics was conducted and the most appropriate tool (QA Fortran) was acquired; and the tool usage was demonstrated on three sample programs. (author) 5 refs

  4. Applying revised gap analysis model in measuring hotel service quality.

    Science.gov (United States)

    Lee, Yu-Cheng; Wang, Yu-Che; Chien, Chih-Hung; Wu, Chia-Huei; Lu, Shu-Chiung; Tsai, Sang-Bing; Dong, Weiwei

    2016-01-01

    With the number of tourists coming to Taiwan growing by 10-20 % since 2010, the number has increased due to an increasing number of foreign tourists, particularly after deregulation allowed admitting tourist groups, followed later on by foreign individual tourists, from mainland China. The purpose of this study is to propose a revised gap model to evaluate and improve service quality in Taiwanese hotel industry. Thus, service quality could be clearly measured through gap analysis, which was more effective for offering direction in developing and improving service quality. The HOLSERV instrument was used to identify and analyze service gaps from the perceptions of internal and external customers. The sample for this study included three main categories of respondents: tourists, employees, and managers. The results show that five gaps influenced tourists' evaluations of service quality. In particular, the study revealed that Gap 1 (management perceptions vs. customer expectations) and Gap 9 (service provider perceptions of management perceptions vs. service delivery) were more critical than the others in affecting perceived service quality, making service delivery the main area of improvement. This study contributes toward an evaluation of the service quality of the Taiwanese hotel industry from the perspectives of customers, service providers, and managers, which is considerably valuable for hotel managers. It was the aim of this study to explore all of these together in order to better understand the possible gaps in the hotel industry in Taiwan.

  5. Workshop on measurement quality assurance for ionizing radiation: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Heath, J.A.; Swinth, K.L. [comps.

    1993-12-31

    This workshop was held to review the status of secondary level calibration accreditation programs, review related measurement accreditation programs, document lessons learned, and to present changes in programs due to new national priorities involving radioactivity measurements. Contents include: fundamentals of measurement quality assurance (MQA), standards for MQA programs; perspectives and policies; complete MQA programs; future MQA programs; QA/QC programs--radioactivity; QA/QC programs--dosimetry; laboratory procedures for QA/QC; in-house control of reference dosimetry laboratories; in-house controls of radioactivity laboratories; and poster session. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  6. Workshop on measurement quality assurance for ionizing radiation: Proceedings

    International Nuclear Information System (INIS)

    Heath, J.A.; Swinth, K.L.

    1993-01-01

    This workshop was held to review the status of secondary level calibration accreditation programs, review related measurement accreditation programs, document lessons learned, and to present changes in programs due to new national priorities involving radioactivity measurements. Contents include: fundamentals of measurement quality assurance (MQA), standards for MQA programs; perspectives and policies; complete MQA programs; future MQA programs; QA/QC programs--radioactivity; QA/QC programs--dosimetry; laboratory procedures for QA/QC; in-house control of reference dosimetry laboratories; in-house controls of radioactivity laboratories; and poster session. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  7. Measurement system with high accuracy for laser beam quality.

    Science.gov (United States)

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  8. Quality assurance of the Brewer spectral UV measurements in Finland

    Directory of Open Access Journals (Sweden)

    K. Lakkala

    2008-06-01

    Full Text Available The quality assurance of the two Brewer spectrophotometers of the Finnish Meteorological Institute is discussed in this paper. The complete data processing chain from raw signal to high quality spectra is presented. The quality assurance includes daily maintenance, laboratory characterizations, calculation of long-term spectral responsivity, data processing and quality assessment. The cosine correction of the measurements is based on a new method, and is included in the data processing software. The results showed that the actual cosine correction factor of the two Finnish Brewers can vary between 1.08–1.13 and 1.08–1.12, respectively, depending on the sky radiance distribution and wavelength. The temperature characterization showed a linear temperature dependence between the instruments' internal temperature and the photon counts per cycle, and a temperature correction was used for correcting the measurements. The long-term spectral responsivity was calculated using the time series of several lamps using two slightly different methods. The long-term spectral responsivity was scaled to the irradiance scale of the Helsinki University of Technology (HUT for the whole of the measurement time-periods 1990–2006 and 1995–2006 for Sodankylä and Jokioinen, respectively. Both Brewers have participated in many international spectroradiometer comparisons, and have shown good stability. The differences between the Brewers and the portable reference spectroradiometer QASUME have been within 5% during 2002–2007.

  9. Assessment of quality of measurement results in interlaboratory comparisons

    International Nuclear Information System (INIS)

    Rosskopfova, O.; Matel, L.; Rajec, P.

    2009-01-01

    Testing laboratory accredited according to ISO/IEC 17025:2005 has to ensure the quality of their results. Important aspect of correct evaluation of the result is the accuracy and uncertainty. Requirement of ISO/IEC 17025:2005 is the accredited laboratories to express their results with the corresponding uncertainty. Participation of laboratories in interlaboratory comparisons provides objective evidence of the level of reliability and quality of their results. Thereby the competency of accredited laboratories verified, including the verification of the declared measurement uncertainty. Some interlaboratory comparisons in which took participation the Testing Laboratory of Radiochemical Analysis (LARCHA) are presented.

  10. Measurement of Quality of Life I. A Methodological Framework

    Directory of Open Access Journals (Sweden)

    Soren Ventegodt

    2003-01-01

    Full Text Available Despite the widespread acceptance of quality of life (QOL as the ideal guideline in healthcare and clinical research, serious conceptual and methodological problems continue to plague this area. In an attempt to remedy this situation, we propose seven criteria that a quality-of-life concept must meet to provide a sound basis for investigation by questionnaire. The seven criteria or desiderata are: (1 an explicit definition of quality of life; (2 a coherent philosophy of human life from which the definition is derived; (3 a theory that operationalizes the philosophy by specifying unambiguous, nonoverlapping, and jointly exhaustive questionnaire items; (4 response alternatives that permit a fraction-scale interpretation; (5 technical checks of reproducibility; (6 meaningfulness to investigators, respondents, and users; and (7 an overall aesthetic appeal of the questionnaire. These criteria have guided the design of a validated 5-item generic, global quality-of-life questionnaire (QOL5, and a validated 317-item generic, global quality-of-life questionnaire (SEQOL, administered to a well-documented birth cohort of 7,400 Danes born in 1959�1961, as well as to a reference sample of 2,500 Danes. Presented in outline, the underlying integrative quality-of-life (IQOL theory is a meta-theory. To illustrate the seven criteria at work, we show the extent to which they are satisfied by one of the eight component theories. Next, two sample results of our investigation are presented: satisfaction with one's sex life has the expected covariation with one's quality of life, and so does mother's smoking during pregnancy, albeit to a much smaller extent. It is concluded that the methodological framework presented has proved helpful in designing a questionnaire that is capable of yielding acceptably valid and reliable measurements of global and generic quality of life.

  11. Measuring quality of dental care: Caries prevention services for children.

    Science.gov (United States)

    Herndon, Jill Boylston; Tomar, Scott L; Catalanotto, Frank A; Rudner, Nancy; Huang, I-Chan; Aravamudhan, Krishna; Shenkman, Elizabeth A; Crall, James J

    2015-08-01

    The authors conducted a study to validate the following 3 evidence-based, process-of-care quality measures focused on dental caries prevention for children with an elevated risk of experiencing caries: sealants for 6- to 9-year-olds, sealants for 10- to 14-year-olds, and topical fluoride. Using evidence-based guidelines, the Dental Quality Alliance developed measures for implementation with administrative data at the plan and program levels. To validate the measures, the authors used data from the Florida and Texas Medicaid programs and Children's Health Insurance Programs and from national commercial dental benefit plans. Data were extracted from 414 randomly selected dental office records to validate the use of administrative data to accurately calculate the measures. The authors also assessed statistically significant variations in overall measure performance. Agreement between administrative data and dental records was 95% for sealants (κ = 0.82) and 90% for topical fluoride (κ = 0.78). Sensitivity and specificity were 90.7% and 88.5% for topical fluoride and 77.8% and 98.8% for sealants, respectively. Variation in overall measure performance was greatest for topical fluoride (χ(2) = 5,887.1; P caries received at least 2 topical fluoride applications during the reporting year. Although there was greater variation in performance for sealants for 6- to 9-year-olds (range, 21.0-31.3%; χ(2) = 548.6; P caries prevention process-of-care quality measures can be implemented feasibly and validly using administrative claims data. The measures can be used to assess, monitor, and improve the proportion of children with an elevated risk of experiencing dental caries who receive evidence-based caries prevention services. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  12. Rural southeast Texas air quality measurements during the 2006 Texas Air Quality Study.

    Science.gov (United States)

    Schade, Gunnar W; Khan, Siraj; Park, Changhyoun; Boedeker, Ian

    2011-10-01

    The authors conducted air quality measurements of the criteria pollutants carbon monoxide, nitrogen oxides, and ozone together with meteorological measurements at a park site southeast of College Station, TX, during the 2006 Texas Air Quality Study II (TexAQS). Ozone, a primary focus of the measurements, was above 80 ppb during 3 days and above 75 ppb during additional 8 days in summer 2006, suggestive of possible violations of the ozone National Ambient Air Quality Standard (NAAQS) in this area. In concordance with other air quality measurements during the TexAQS II, elevated ozone mixing ratios coincided with northerly flows during days after cold front passages. Ozone background during these days was as high as 80 ppb, whereas southerly air flows generally provided for an ozone background lower than 40 ppb. Back trajectory analysis shows that local ozone mixing ratios can also be strongly affected by the Houston urban pollution plume, leading to late afternoon ozone increases of as high as 50 ppb above background under favorable transport conditions. The trajectory analysis also shows that ozone background increases steadily the longer a southern air mass resides over Texas after entering from the Gulf of Mexico. In light of these and other TexAQS findings, it appears that ozone air quality is affected throughout east Texas by both long-range and regional ozone transport, and that improvements therefore will require at least a regionally oriented instead of the current locally oriented ozone precursor reduction policies.

  13. Akademisk video

    DEFF Research Database (Denmark)

    Frølunde, Lisbeth

    2017-01-01

    Dette kapitel har fokus på metodiske problemstillinger, der opstår i forhold til at bruge (digital) video i forbindelse med forskningskommunikation, ikke mindst online. Video har længe været benyttet i forskningen til dataindsamling og forskningskommunikation. Med digitaliseringen og internettet ...

  14. Measuring ICT usage quality for information society building

    DEFF Research Database (Denmark)

    Schlichter, Bjarne Rerup; Danylchenko, Lesya

    2014-01-01

    In 2003 the World Summit on Information Society made a call for measuring the state of Information Society (IS) building between countries. The purpose of the measuring was to assess and compare IS practices around the globe as well as share best practices. A number of measurement tools have sinc...... levels of ICT usage for the purpose of better policy-making, while establishing an information society, is accentuated....... these indicators on the actual levels of Information and Communication Technology (ICT) usage off the country’s stakeholders. This paper analyses the most currently used indices for measuring the state of Information Society building from the perspective of their constituent indicators. Based on the analysis......, an alternative framework for IS measurement, addressing the important aspects of ICT usage quality, is developed based on data from EU member states. By applying the framework on measuring of ICT usage quality at Romania, Cyprus and Estonia, the usefulness is tested positive, and the need to evaluate the actual...

  15. Using quality measures for quality improvement: the perspective of hospital staff.

    Directory of Open Access Journals (Sweden)

    Asgar Aghaei Hashjin

    Full Text Available RESEARCH OBJECTIVE: This study examines the perspectives of a range of key hospital staff on the use, importance, scientific background, availability of data, feasibility of data collection, cost benefit aspects and availability of professional personnel for measurement of quality indicators among Iranian hospitals. The study aims to facilitate the use of quality indicators to improve quality of care in hospitals. STUDY DESIGN: A cross-sectional study was conducted over the period 2009 to 2010. Staff at Iranian hospitals completed a self-administered questionnaire eliciting their views on organizational, clinical process, and outcome (clinical effectiveness, patient safety and patient centeredness indicators. POPULATION STUDIED: 93 hospital frontline staff including hospital/nursing managers, medical doctors, nurses, and quality improvement/medical records officers in 48 general and specialized hospitals in Iran. PRINCIPAL FINDINGS: On average, only 69% of respondents reported using quality indicators in practice at their affiliated hospitals. Respondents varied significantly in their reported use of organizational, clinical process and outcome quality indicators. Overall, clinical process and effectiveness indicators were reported to be least used. The reported use of indicators corresponded with their perceived level of importance. Quality indicators were reported to be used among clinical staff significantly more than among managerial staff. In total, 74% of the respondents reported to use obligatory indicators, while this was 68% for voluntary indicators (p<0.05. CONCLUSIONS: There is a general awareness of the importance and usability of quality indicators among hospital staff in Iran, but their use is currently mostly directed towards external accountability purposes. To increase the formative use of quality indicators, creation of a common culture and feeling of shared ownership, alongside an increased uptake of clinical process and

  16. Measuring device for water quality at reactor bottom

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Hidehiro; Takagi, Jun-ichi

    1995-10-27

    The present invention concerns measurement for water quality at the bottom of a reactor of a BWR type plant, in which reactor water is sampled and analyzed in a state approximate to conditions in a pressure vessel. Based on the result, hydrogen injection amount is controlled during hydrogen injection operation. Namely, a monitor for water quality is disposed to a sampling line in communication with the bottom of a pressure vessel. A water quality monitor is disposed to a drain sampling line in communication with the bottom of the pressure vessel. A corrosion potentiometer is disposed to the pressure sampling line or the drain sampling line. A dissolved oxygen measuring device is disposed to the pressure vessel sampling line or the drain sampling line. With such a constitution, the reactor water can be sampled and analyzed in a state approximate to the conditions in the pressure vessel. In addition, signals from the water quality monitor are inputted to a hydrogen injection amount control device. As a result, the amount of hydrogen injected to primary coolants can be controlled in a state approximate to the conditions in the pressure vessel. (I.S.).

  17. Measuring device for water quality at reactor bottom

    International Nuclear Information System (INIS)

    Urata, Hidehiro; Takagi, Jun-ichi.

    1995-01-01

    The present invention concerns measurement for water quality at the bottom of a reactor of a BWR type plant, in which reactor water is sampled and analyzed in a state approximate to conditions in a pressure vessel. Based on the result, hydrogen injection amount is controlled during hydrogen injection operation. Namely, a monitor for water quality is disposed to a sampling line in communication with the bottom of a pressure vessel. A water quality monitor is disposed to a drain sampling line in communication with the bottom of the pressure vessel. A corrosion potentiometer is disposed to the pressure sampling line or the drain sampling line. A dissolved oxygen measuring device is disposed to the pressure vessel sampling line or the drain sampling line. With such a constitution, the reactor water can be sampled and analyzed in a state approximate to the conditions in the pressure vessel. In addition, signals from the water quality monitor are inputted to a hydrogen injection amount control device. As a result, the amount of hydrogen injected to primary coolants can be controlled in a state approximate to the conditions in the pressure vessel. (I.S.)

  18. Quality of life issues and measurement in patients with psoriasis

    Directory of Open Access Journals (Sweden)

    Tan X

    2012-02-01

    Full Text Available Xi Tan1, Steven R Feldman2, Rajesh Balkrishnan11Department of Clinical, Social and Administrative Sciences, College of Pharmacy, University of Michigan, Ann Arbor, MI, USA; 2Department of Dermatology, Wake Forest University School of Medicine, Winston-Salem, NC, USAAbstract: Psoriasis is a chronic immunologic disease characterized by red papules and plaques with a silver colored scale. The impact of psoriasis on patients’ overall quality of life is significant, broad, and deep, including effects on emotional wellbeing, psychological stress, self-esteem, relationship, work, social activities, financial burden, and even physical function. Although there are various measures available for assessing health-related quality of life (HRQoL in research studies, there is no consensus on which measure is best to use in clinical practice or for research comparing different treatments. Choosing treatments based on patients’ specific individual preferences, goal-orientation, and close, attentive cooperation between patients and their doctors may be an effective strategy that can be applied to improve patients’ quality of life.Keywords: treatment, health related quality of life, HRQoL

  19. How to Measure and Interpret Quality Improvement Data.

    Science.gov (United States)

    McQuillan, Rory Francis; Silver, Samuel Adam; Harel, Ziv; Weizman, Adam; Thomas, Alison; Bell, Chaim; Chertow, Glenn M; Chan, Christopher T; Nesrallah, Gihad

    2016-05-06

    This article will demonstrate how to conduct a quality improvement project using the change idea generated in "How To Use Quality Improvement Tools in Clinical Practice: How To Diagnose Solutions to a Quality of Care Problem" by Dr. Ziv Harel and colleagues in this Moving Points feature. This change idea involves the introduction of a nurse educator into a CKD clinic with a goal of increasing rates of patients performing dialysis independently at home (home hemodialysis or peritoneal dialysis). Using this example, we will illustrate a Plan-Do-Study-Act (PDSA) cycle in action and highlight the principles of rapid cycle change methodology. We will then discuss the selection of outcome, process, and balancing measures, and the practicalities of collecting these data in the clinic environment. We will also introduce the PDSA worksheet as a practical way to oversee the progress of a quality improvement project. Finally, we will demonstrate how run charts are used to visually illustrate improvement in real time, and how this information can be used to validate achievement, respond appropriately to challenges the project may encounter, and prove the significance of results. This article aims to provide readers with a clear and practical framework upon which to trial their own ideas for quality improvement in the clinical setting. Copyright © 2016 by the American Society of Nephrology.

  20. MEASURING THE DATA MODEL QUALITY IN THE ESUPPLY CHAINS

    Directory of Open Access Journals (Sweden)

    Zora Arsovski

    2012-03-01

    Full Text Available The implementation of Internet technology in business has enabled the development of e-business supply chains with large-scale information integration among all partners.The development of information systems (IS is based on the established business objectives whose achievement, among other things, directly depends on the quality of development and design of IS. In the process of analysis of the key elements of company operations in the supply chain, process model and corresponding data model are designed which should enable selection of appropriate information system architecture. The quality of the implemented information system, which supports e-supply chain, directly depends on the level of data model quality. One of the serious limitations of the data model is its complexity. With a large number of entities, data model is difficult to analyse, monitor and maintain. The problem gets bigger when looking at an integrated data model at the level of participating partners in the supply chain, where the data model usually consists of hundreds or even thousands of entities.The paper will analyse the key elements affecting the quality of data models and show their interactions and factors of significance. In addition, the paper presents various measures for assessing the quality of the data model on which it is possible to easily locate the problems and focus efforts in specific parts of a complex data model where it is not economically feasible to review every detail of the model.

  1. Measuring and Assuring the Quality of Home Health Care

    Science.gov (United States)

    Shaughnessy, Peter W.; Crisler, Kathryn S.; Schlenker, Robert E.; Arnold, Angela G.; Kramer, Andrew M.; Powell, Martha C.; Hittle, David F.

    1994-01-01

    The growth in home health care in the United States since 1970, and the exponential increase in the provision of Medicare-covered home health services over the past 5 years, underscores the critical need to assess the effectiveness of home health care in our society. This article presents conceptual and applied topics and approaches involved in assessing effectiveness through measuring the outcomes of home health care. Definitions are provided for a number of terms that relate to quality of care, outcome measures, risk adjustment, and quality assurance (QA) in home health care. The goal is to provide an overview of a potential systemwide approach to outcome-based QA that has its basis in a partnership between the home health industry and payers or regulators. PMID:10140157

  2. Understanding why an active video game intervention did not improve motor skill and physical activity in children with developmental coordination disorder: A quantity or quality issue?

    Science.gov (United States)

    Howie, Erin K; Campbell, Amity C; Abbott, Rebecca A; Straker, Leon M

    2017-01-01

    Active video games (AVGs) have been identified as a novel strategy to improve motor skill and physical activity in clinical populations. A recent cross-over randomized trial found AVGs to be ineffective at improving motor skill and physical activity in the home-environment for children with or at-risk for developmental coordination disorder (DCD). The study purpose was to better understand why the intervention had been ineffective by examining the quantity and quality of AVG play during an AVG intervention for children with or at-risk for DCD. Participants (n=21, ages 9-12) completed the 16 week AVG intervention. Detailed quantitative and qualitative data were systematically triangulated to obtain the quantity of exposure (AVG exposure over time, patterns of exposure) and quality of use (game selection, facilitators and barriers to play). The median AVG dose (range 30-35min/day) remained relatively stable across the intervention and met the prescribed dose. Play quality was impacted by game selection, difficulty playing games, lack of time, illness, technical difficulties and boredom. The ineffectiveness of a home-based AVG intervention may be due to quality of play. Strategies to improve the quality of game play may help realize the potential benefits of AVGs as a clinical tool for children with DCD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. MEASURING GROCERY STORES SERVICE QUALITY IN INDONESIA: A RETAIL SERVICE QUALITY SCALE APPROACH

    Directory of Open Access Journals (Sweden)

    Leonnard Leonnard

    2017-12-01

    Full Text Available The growing number of modern grocery stores in Indonesia is a challenge for each grocery store to maintain and increase their number of consumers. The success of maintaining and improving service quality will affect long-term profitability and business sustainability. Therefore, in this study, we examined consumer perceptions of service quality in one of modern grocery stores in Indonesia. Data were collected from 387 consumers of grocery stores in Jakarta, Bogor, Depok, Bekasi, Cibubur, and Subang. Structural Equation Modeling (SEM through Maximum likelihood and Bayesian estimation was employed to analyze the data. The finding indicated that the five indicators of the retail service quality scale consisting of physical aspects, reliability, personal interactions, problem solving and policies provided  valid multi-item instruments in measuring consumer perceptions of service quality in grocery stores.

  4. Quality assurance measures at the Geesthacht research reactor FRG-1

    International Nuclear Information System (INIS)

    Voss, J.; Krull, W.; Schmidt, K.

    1995-01-01

    The major part of the quality system for the FRG is already in practical use; other parts require extensive preparations and therefore transition periods of different lengths before they can be introduced. GKSS is aware that beside the other upgrading and refurbishment activities, these duality assurance measures will be very important in ensuring the operation of the FRG-1 research reactor over the coming 15 years or more. (orig.)

  5. Quality Measurement in the Wood Products Supply Chain

    OpenAIRE

    Espinoza, Omar Alejandro

    2009-01-01

    The purpose of this research is to learn about quality measurement practices in a wood products supply chain. According to the Supply Chain Management paradigm, companies no longer compete as individual entities, but as part of complex networks of suppliers and customers, linked together by flows of materials and information. Evidence suggests that a high degree of integration between supply chain members is essential to achieve superior market and financial performance. This study investigat...

  6. MEASURING AND MODELLING INTERNET BANKING SERVICE QUALITY IN SOUTH AFRICA

    OpenAIRE

    Redda, Ephrem Habtemichael; Surujlal, Jhalukpreya

    2017-01-01

    The purpose of this study was to develop a measuring and modelling instrument of Internet banking service quality (IBSQ) for the South African banking sector. Snowball and convenience sampling, both non-probability techniques were used to recruit participants for the study. A total of 310 Internet banking customer responses were utilised in the analysis. Using exploratory factor analysis (EFA), eight determinant factors that explained IBSQ were extracted. Following this, the study...

  7. Quality Measures for Dialysis: Time for a Balanced Scorecard.

    Science.gov (United States)

    Kliger, Alan S

    2016-02-05

    Recent federal legislation establishes a merit-based incentive payment system for physicians, with a scorecard for each professional. The Centers for Medicare and Medicaid Services evaluate quality of care with clinical performance measures and have used these metrics for public reporting and payment to dialysis facilities. Similar metrics may be used for the future merit-based incentive payment system. In nephrology, most clinical performance measures measure processes and intermediate outcomes of care. These metrics were developed from population studies of best practice and do not identify opportunities for individualizing care on the basis of patient characteristics and individual goals of treatment. The In-Center Hemodialysis (ICH) Consumer Assessment of Healthcare Providers and Systems (CAHPS) survey examines patients' perception of care and has entered the arena to evaluate quality of care. A balanced scorecard of quality performance should include three elements: population-based best clinical practice, patient perceptions, and individually crafted patient goals of care. Copyright © 2016 by the American Society of Nephrology.

  8. Does Input Quality Drive Measured Differences in Firm Productivity?

    DEFF Research Database (Denmark)

    Fox, Jeremy T.; Smeets, Valerie Anne Rolande

    2011-01-01

    One explanation for productivity dispersion is that the quality of inputs differs across firms. We add labor market history variables such as experience and firm and industry tenure, as well as general human capital measures such as schooling and sex. Adding these variables decreases the ratio...... of the 90th to 10th productivity quantiles from 3.27 to 2.68 across eight Danish manufacturing and service industries. We also use the wage bill and worker fixed effects. We find that the wage bill explains as much dispersion as human capital measures....

  9. Bronchial blocker versus left double-lumen endotracheal tube in video-assisted thoracoscopic surgery: a randomized-controlled trial examining time and quality of lung deflation.

    Science.gov (United States)

    Bussières, Jean S; Somma, Jacques; Del Castillo, José Luis Carrasco; Lemieux, Jérôme; Conti, Massimo; Ugalde, Paula A; Gagné, Nathalie; Lacasse, Yves

    2016-07-01

    Double-lumen endotracheal tubes (DL-ETT) and bronchial blockers (BB) have both been used for lung isolation in video-assisted thoracic surgery (VATS). Though not well studied, it is widely thought that a DL-ETT provides faster and better quality lung collapse. The aim of this study was to compare a BB technique vs a left-sided DL-ETT strategy with regard to the time and quality of lung collapse during one-lung ventilation (OLV) for elective VATS. Forty patients requiring OLV for VATS were randomized to receive a BB (n = 20) or a left-sided DL-ETT (n = 20). The primary endpoint was the time from pleural opening (performed by the surgeon) until complete lung collapse. The time was evaluated offline by reviewing video recorded during the VATS. The quality of lung deflation was also graded offline using a visual scale (1 = no lung collapse; 2 = partial lung collapse; and 3 = total lung collapse) and was recorded at several time points after pleural incision. The surgeon also graded the time to complete lung collapse and quality of lung deflation during the procedure. The surgeon's guess as to which device was used for lung isolation was also recorded. Of the 40 patients enrolled in the study, 20 patients in the DL-ETT group and 18 in the BB group were analyzed. There mean (standard deviation) time to complete lung collapse of the operative lung was significantly faster using the BB compared with using the DL-ETT [7.5 (3.8) min vs 36.6 (29.1) min, respectively; mean difference, 29.1 min; 95% confidence interval, 1.8 to 7.2; P < 0.001]. Overall, a higher proportion of patients in the BB group than in the DL-ETT group achieved a quality of lung collapse score of 3 at five minutes (57% vs 6%, respectively; P < 0.004), ten minutes (73% vs 14%, respectively; P = 0.005), and 20 min (100% vs 25%, respectively; P = 0.002) after opening the pleura. The surgeon incorrectly guessed the type of device used in 78% of the BB group and 50% of the DL-ETT group (P = 0.10). The time and

  10. Video error concealment using block matching and frequency selective extrapolation algorithms

    Science.gov (United States)

    P. K., Rajani; Khaparde, Arti

    2017-06-01

    Error Concealment (EC) is a technique at the decoder side to hide the transmission errors. It is done by analyzing the spatial or temporal information from available video frames. It is very important to recover distorted video because they are used for various applications such as video-telephone, video-conference, TV, DVD, internet video streaming, video games etc .Retransmission-based and resilient-based methods, are also used for error removal. But these methods add delay and redundant data. So error concealment is the best option for error hiding. In this paper, the error concealment methods such as Block Matching error concealment algorithm is compared with Frequency Selective Extrapolation algorithm. Both the works are based on concealment of manually error video frames as input. The parameter used for objective quality measurement was PSNR (Peak Signal to Noise Ratio) and SSIM(Structural Similarity Index). The original video frames along with error video frames are compared with both the Error concealment algorithms. According to simulation results, Frequency Selective Extrapolation is showing better quality measures such as 48% improved PSNR and 94% increased SSIM than Block Matching Algorithm.

  11. Power quality measurement service in the support of large customers

    Energy Technology Data Exchange (ETDEWEB)

    Levesque, F. [Hydro-Quebec, Montreal, PQ (Canada)

    2006-07-01

    Power quality and how it is measured among Hydro Quebec's major customers were the focus of this conference presentation. Background information on Hydro Quebec and its customers was provided with reference to information on clients, employees and how the organization is organized. The presentation also included a discussion of power quality and how it is delivered at Hydro Quebec. For example, characteristics and target values of the voltage supplied by Hydro Quebec for high, medium and low voltages were examined. Personnel responsible for the grid have created a system to document each event submitted by customers. Documenting the actual power quality at the point of common coupling allows benchmarking of real data against announced characteristics and target values. This approach quantifies disturbances and helps to find and focus on disturbances that really influence large customers, mainly industrials. Portable and permanent installations issues were discussed followed by a discussion of a new service offering power quality metering on a regular basis. This metering service includes a complete analysis and technical support with dedicated expertise since customers are rarely fully experienced in power quality. The metering service is presented from the perspective of preventive maintenance with continuous quantification of a large number of indicators to assess the quality of the delivered power. Essential tools that customers can benefit from with this new service include real time electronic mail notification, weekly reporting and ad hoc technical support. This combination of various levels of services allows Hydro-Quebec to address the needs of these large customers in a flexible way. figs.

  12. Assuring measurement quality in person-centred healthcare

    Science.gov (United States)

    Pendrill, L. R.

    2018-03-01

    Is it realistic to aspire to the same kind of quality-assurance of measurement in person-centred care, currently being implemented in healthcare globally, as is established in the physical sciences and engineering? Ensuring metrological comparability (‘traceability’) and reliably declaring measurement uncertainty when assessing patient ability or increased social capital are however challenging for subjective measurements often characterised by large dispersion. Drawing simple analogies between ‘instruments’ in the social sciences—questionnaires, ability tests, etc—and engineering instruments such as thermometers does not go far enough. A possible way forward, apparently equally applicable to both physical and social measurement, seems to be to model inferences in terms of performance metrics of a measurement system. Person-centred care needs person-centred measurement and a full picture of the measurement process when man acts as a measurement instrument is given in the present paper. This complements previous work by presenting the process, step by step, from the observed indication (e.g. probability of success, P success, of achieving a task), through restitution with Rasch measurement theory, to the measurand (e.g. task difficulty). Rasch invariant measure theory can yield quantities—‘latent’ (or ‘explanatory’) variables such as task challenge or person ability—with characteristics akin to those of physical quantities. Metrological references for comparability via traceability and reliable estimates of uncertainty and decision risks are then in reach even for perceptive measurements (and other qualitative properties). As a case study, the person-centred measurement of cognitive ability is examined, as part of the EU project EMPIR 15HLT04 NeuroMet, for Alzheimer’s, where better analysis of correlations with brain atrophy is enabled thanks to the Rasch metrological approach.

  13. Otoplasty Online Information: A Comprehensive Analysis of the Websites and Videos that Patients View Regarding Cosmetic Ear Surgery.

    Science.gov (United States)

    Nissan, Michael E; Gupta, Amar; Rayess, Hani; Black, Kevin Z; Carron, Michael

    2018-02-01

    Physicians should be aware of both websites and videos available online regarding the otoplasty procedure to provide quality care. This study systematically analyzes the authorships, reliability, quality, and readability of the websites, as well as the authorships and primary objectives of the videos regarding otoplasty. Validated instruments were used to analyze the reliability, quality, and readability of websites, and videos were systematically categorized and analyzed. A Google search was conducted, and the first five pages of results were included in this study. After excluding unrelated websites, the remaining 44 websites were categorized by authorship (physician, patient, academic, or unaffiliated) and were analyzed using the validated DISCERN instrument for reliability and quality, as well as various other validated instruments to measure readability. A YouTube search was also conducted, and the first 50 relevant videos were included in the study. These videos were categorized by authorship and their primary objective. Website authorships were physician-dominated. Reliability, quality, and overall DISCERN score differ between the four authorship groups by a statistically significant margin (Kruskall-Wallis test, p  < 0.05). Unaffiliated websites were the most reliable, and physician websites were the least reliable. Academic websites were of the highest quality, and patient websites were of the lowest quality. Readability did not differ significantly between the groups, though the readability measurements made showed a general lack of material easily readable by the general public. YouTube was likewise dominated by physician-authored videos. While the physician-authored videos sought mainly to inform and to advertise, patient-authored videos sought mainly to provide the patient's perspective. Academic organizations showed very little representation on YouTube, and the YouTube views on otoplasty videos were dominated by the top 20 videos, which

  14. Quality assessment of solar UV irradiance measured with array spectroradiometers

    Science.gov (United States)

    Egli, Luca; Gröbner, Julian; Hülsen, Gregor; Bachmann, Luciano; Blumthaler, Mario; Dubard, Jimmy; Khazova, Marina; Kift, Richard; Hoogendijk, Kees; Serrano, Antonio; Smedley, Andrew; Vilaplana, José-Manuel

    2016-04-01

    The reliable quantification of ultraviolet (UV) radiation at the earth's surface requires accurate measurements of spectral global solar UV irradiance in order to determine the UV exposure to human skin and to understand long-term trends in this parameter. Array spectroradiometers (ASRMs) are small, light, robust and cost-effective instruments, and are increasingly used for spectral irradiance measurements. Within the European EMRP ENV03 project "Solar UV", new devices, guidelines and characterization methods have been developed to improve solar UV measurements with ASRMs, and support to the end user community has been provided. In order to assess the quality of 14 end user ASRMs, a solar UV intercomparison was held on the measurement platform of the World Radiation Center (PMOD/WRC) in Davos, Switzerland, from 10 to 17 July 2014. The results of the blind intercomparison revealed that ASRMs, currently used for solar UV measurements, show a large variation in the quality of their solar UV measurements. Most of the instruments overestimate the erythema-weighted UV index - in particular at large solar zenith angles - due to stray light contribution in the UV-B range. The spectral analysis of global solar UV irradiance further supported the finding that the uncertainties in the UV-B range are very large due to stray light contribution in this wavelength range. In summary, the UV index may be detected by some commercially available ASRMs within 5 % compared to the world reference spectroradiometer, if well characterized and calibrated, but only for a limited range of solar zenith angles. Generally, the tested instruments are not yet suitable for solar UV measurements for the entire range between 290 and 400 nm under all atmospheric conditions.

  15. A quantitative method for measuring the quality of history matches

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, T.S. [Kerr-McGee Corp., Oklahoma City, OK (United States); Knapp, R.M. [Univ. of Oklahoma, Norman, OK (United States)

    1997-08-01

    History matching can be an efficient tool for reservoir characterization. A {open_quotes}good{close_quotes} history matching job can generate reliable reservoir parameters. However, reservoir engineers are often frustrated when they try to select a {open_quotes}better{close_quotes} match from a series of history matching runs. Without a quantitative measurement, it is always difficult to tell the difference between a {open_quotes}good{close_quotes} and a {open_quotes}better{close_quotes} matches. For this reason, we need a quantitative method for testing the quality of matches. This paper presents a method for such a purpose. The method uses three statistical indices to (1) test shape conformity, (2) examine bias errors, and (3) measure magnitude of deviation. The shape conformity test insures that the shape of a simulated curve matches that of a historical curve. Examining bias errors assures that model reservoir parameters have been calibrated to that of a real reservoir. Measuring the magnitude of deviation assures that the difference between the model and the real reservoir parameters is minimized. The method was first tested on a hypothetical model and then applied to published field studies. The results showed that the method can efficiently measure the quality of matches. It also showed that the method can serve as a diagnostic tool for calibrating reservoir parameters during history matching.

  16. Video Podcasts

    DEFF Research Database (Denmark)

    Nortvig, Anne Mette; Sørensen, Birgitte Holm

    2016-01-01

    This project’s aim was to support and facilitate master’s students’ preparation and collaboration by making video podcasts of short lectures available on YouTube prior to students’ first face-to-face seminar. The empirical material stems from group interviews, from statistical data created through...... YouTube analytics and from surveys answered by students after the seminar. The project sought to explore how video podcasts support learning and reflection online and how students use and reflect on the integration of online activities in the videos. Findings showed that students engaged actively...

  17. Video games.

    Science.gov (United States)

    Funk, Jeanne B

    2005-06-01

    The video game industry insists that it is doing everything possible to provide information about the content of games so that parents can make informed choices; however, surveys indicate that ratings may not reflect consumer views of the nature of the content. This article describes some of the currently popular video games, as well as developments that are on the horizon, and discusses the status of research on the positive and negative impacts of playing video games. Recommendations are made to help parents ensure that children play games that are consistent with their values.

  18. Robust Watermarking of Video Streams

    Directory of Open Access Journals (Sweden)

    T. Polyák

    2006-01-01

    Full Text Available In the past few years there has been an explosion in the use of digital video data. Many people have personal computers at home, and with the help of the Internet users can easily share video files on their computer. This makes possible the unauthorized use of digital media, and without adequate protection systems the authors and distributors have no means to prevent it.Digital watermarking techniques can help these systems to be more effective by embedding secret data right into the video stream. This makes minor changes in the frames of the video, but these changes are almost imperceptible to the human visual system. The embedded information can involve copyright data, access control etc. A robust watermark is resistant to various distortions of the video, so it cannot be removed without affecting the quality of the host medium. In this paper I propose a video watermarking scheme that fulfills the requirements of a robust watermark. 

  19. Integration of the effects of air quality measures in the SOLVE mix of measures

    International Nuclear Information System (INIS)

    Hesselmans, T.; Heijnis, F.

    2008-01-01

    SOLVE is the Dutch abbreviation for fast solutions for air and traffic and is a website by means of which provinces and municipalities in the Netherlands can gain insight into the best measures for traffic to improve the quality of the ambient air. Since halfway June 2008, the effects on air quality of approximately 35 traffic measures were included in the SOLVE mix of measures. The effects of traffic measures on emissions of particulate matter and nitrogen dioxide have been calculated. The effects are expressed in a decrease of the contribution of traffic indicated in a scale from A (very large decrease) to E (no decrease). The outcome depends on the location where the measure is implemented. [mk] [nl

  20. Data Quality Assurance for Supersonic Jet Noise Measurements

    Science.gov (United States)

    Brown, Clifford A.; Henderson, Brenda S.; Bridges, James E.

    2010-01-01

    The noise created by a supersonic aircraft is a primary concern in the design of future high-speed planes. The jet noise reduction technologies required on these aircraft will be developed using scale-models mounted to experimental jet rigs designed to simulate the exhaust gases from a full-scale jet engine. The jet noise data collected in these experiments must accurately predict the noise levels produced by the full-scale hardware in order to be a useful development tool. A methodology has been adopted at the NASA Glenn Research Center s Aero-Acoustic Propulsion Laboratory to insure the quality of the supersonic jet noise data acquired from the facility s High Flow Jet Exit Rig so that it can be used to develop future nozzle technologies that reduce supersonic jet noise. The methodology relies on mitigating extraneous noise sources, examining the impact of measurement location on the acoustic results, and investigating the facility independence of the measurements. The methodology is documented here as a basis for validating future improvements and its limitations are noted so that they do not affect the data analysis. Maintaining a high quality jet noise laboratory is an ongoing process. By carefully examining the data produced and continually following this methodology, data quality can be maintained and improved over time.