WorldWideScience

Sample records for vibration alarm capabilities

  1. Display-And-Alarm Circuit For Accelerometer

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.

  2. Quantitative Index and Abnormal Alarm Strategy Using Sensor-Dependent Vibration Data for Blade Crack Identification in Centrifugal Booster Fans.

    Science.gov (United States)

    Chen, Jinglong; Sun, Hailiang; Wang, Shuai; He, Zhengjia

    2016-05-09

    Centrifugal booster fans are important equipment used to recover blast furnace gas (BFG) for generating electricity, but blade crack faults (BCFs) in centrifugal booster fans can lead to unscheduled breakdowns and potentially serious accidents, so in this work quantitative fault identification and an abnormal alarm strategy based on acquired historical sensor-dependent vibration data is proposed for implementing condition-based maintenance for this type of equipment. Firstly, three group dependent sensors are installed to acquire running condition data. Then a discrete spectrum interpolation method and short time Fourier transform (STFT) are applied to preliminarily identify the running data in the sensor-dependent vibration data. As a result a quantitative identification and abnormal alarm strategy based on compound indexes including the largest Lyapunov exponent and relative energy ratio at the second harmonic frequency component is proposed. Then for validation the proposed blade crack quantitative identification and abnormality alarm strategy is applied to analyze acquired experimental data for centrifugal booster fans and it has successfully identified incipient blade crack faults. In addition, the related mathematical modelling work is also introduced to investigate the effects of mistuning and cracks on the vibration features of centrifugal impellers and to explore effective techniques for crack detection.

  3. Quantitative Index and Abnormal Alarm Strategy Using Sensor-Dependent Vibration Data for Blade Crack Identification in Centrifugal Booster Fans

    Directory of Open Access Journals (Sweden)

    Jinglong Chen

    2016-05-01

    Full Text Available Centrifugal booster fans are important equipment used to recover blast furnace gas (BFG for generating electricity, but blade crack faults (BCFs in centrifugal booster fans can lead to unscheduled breakdowns and potentially serious accidents, so in this work quantitative fault identification and an abnormal alarm strategy based on acquired historical sensor-dependent vibration data is proposed for implementing condition-based maintenance for this type of equipment. Firstly, three group dependent sensors are installed to acquire running condition data. Then a discrete spectrum interpolation method and short time Fourier transform (STFT are applied to preliminarily identify the running data in the sensor-dependent vibration data. As a result a quantitative identification and abnormal alarm strategy based on compound indexes including the largest Lyapunov exponent and relative energy ratio at the second harmonic frequency component is proposed. Then for validation the proposed blade crack quantitative identification and abnormality alarm strategy is applied to analyze acquired experimental data for centrifugal booster fans and it has successfully identified incipient blade crack faults. In addition, the related mathematical modelling work is also introduced to investigate the effects of mistuning and cracks on the vibration features of centrifugal impellers and to explore effective techniques for crack detection.

  4. Approaching Behaviour Monitor and Vibration Indication in Developing a General Moving Object Alarm System (GMOAS

    Directory of Open Access Journals (Sweden)

    Haiwei Dong

    2013-07-01

    Full Text Available People who suffer from hearing impairment caused by illness, age or extremely noisy environments are constantly in danger of being hit or knocked down by fast moving objects behind them when they have no companion or augmented sensory system to warn them. In this paper, we propose the General Moving Object Alarm System (GMOAS, a system focused on aiding the safe mobility of people under these circumstances. The GMOAS is a wearable haptic device that consists of two main subsystems: (i a moving object monitoring subsystem that uses laser range data to detect and track approaching objects, and (ii an alarm subsystem that warns the user of possibly dangerous approaching objects by triggering tactile vibrations on an “alarm necklace”. For moving object monitoring, we propose a simple yet efficient solution to monitor the approaching behavior of objects. Compared with previous work in motion detection and tracking, we are not interested in specific objects but any type of approaching object that might harm the user. To this extent, we define a boundary in the laser range data where the objects are monitored. Within this boundary a fan-shape grid is constructed to obtain an evenly distributed spatial partitioning of the data. These partitions are efficiently clustered into continuous objects which are then tracked through time using an object association algorithm based on updating a deviation matrix that represents angle, distance and size variations of the objects. The speed of the tracked objects is monitored throughout the algorithm. When the speed of an approaching object surpasses the safety threshold, the alarm necklace is triggered indicating the approaching direction of the fast moving object. The alarm necklace is equipped with three motors that can indicate five directions with respect to the user: left, back, right, left-back and right-back. We performed three types of outdoor experiments (object passing, approaching and crossing that

  5. Development of radiation alarm monitor

    International Nuclear Information System (INIS)

    Myung Jae Song; Myung Chan Lee; Jung Kwan Son

    1997-01-01

    The Radiation Alarm Monitor is developed domestically in order to protect radiation workers from over exposure. The Radiation Alarm Monitor with microprocessor installed can record the information of radiation field before and after accidents. It can also provide the data to analyze the accident and to set a counterplan. It features a wide detection range of radiation (I OmR/h - I OOR/h), radiation work and data storage, portability, high precision (5%) due to calibration, and adaptation of a powerful alarm system. In order to protect workers from over exposure, light and sound alarm had been designed to initiate when accident occurs such as an unexpected change of radiation field such as radiation rate and accumulated dosed between 90 min. before the alarm and 30 min. after the alarm. In addition, the Radiation Alarm Monitor interfaces with computer so that the accident can be analyzed. After the testing conditions in other countries for the Radiation Alarm Monitor were compared, the most stringent test, ANSI N42. 17-A, was selected. The performance testing was car-ried out under various conditions of temperature, humidity, vibration and electromagnetic wave hindrance by Korea Research Institute of Standards and Science (KRISS). As a result, the Radiation Alan-n Monitor passed all test. Also, for the Radiation Alarm Monitor, environmental adaptability tests under the environmental conditions of NPP sites had been performed. The Radiation Alan-n Monitor had been reviewed by radiation workers at NPPs and their opinions had been collected. Operating procedure will be written and distributed to every NPP sites. Radiation Alarm Monitor will be modified for use under the specific environmental conditions of each site. It will be distributed to NPP sites and will be used by radiation workers

  6. Interior intrusion alarm systems

    International Nuclear Information System (INIS)

    Prell, J.A.

    1978-01-01

    In meeting the requirements for the safeguarding of special nuclear material and the physical protection of licensed facilities, the licensee is required to design a physical security system that will meet minimum performance requirements. An integral part of any physical security system is the interior intrusion alarm system. The purpose of this report is to provide the potential user of an interior intrusion alarm system with information on the various types, components, and performance capabilities available so that he can design and install the optimum alarm system for his particular environment. In addition, maintenance and testing procedures are discussed and recommended which, if followed, will help the user obtain the optimum results from his system

  7. Nuclear power plant alarm systems: Problems and issues

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Brown, W.S.

    1991-01-01

    Despite the incorporation of advanced technology into nuclear power plant alarm systems, human factors problems remain. This paper identifies to be addressed in order to allow advanced technology to be used effectively in the design of nuclear power plant alarm systems. The operator's use and processing of alarm system information will be considered. Based upon a review of alarm system research, issues related to general system design, alarm processing, display and control are discussed. It is concluded that the design of effective alarm systems depends on an understanding of the information processing capabilities and limitations of the operator. 39 refs

  8. Nuclear power plant alarm systems: Problems and issues

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, J.M.; Brown, W.S.

    1991-01-01

    Despite the incorporation of advanced technology into nuclear power plant alarm systems, human factors problems remain. This paper identifies to be addressed in order to allow advanced technology to be used effectively in the design of nuclear power plant alarm systems. The operator's use and processing of alarm system information will be considered. Based upon a review of alarm system research, issues related to general system design, alarm processing, display and control are discussed. It is concluded that the design of effective alarm systems depends on an understanding of the information processing capabilities and limitations of the operator. 39 refs.

  9. Advanced alarm management system

    International Nuclear Information System (INIS)

    Easter, J.R.

    1995-01-01

    The Westinghouse Advanced Alarm Management System (AWARE) is one of the Man-Machine Design Interfaces (MMI) which has great flexibility with regard to hardware type and configuration, alarm system concept, plant scope, engineering scope and installation. The AWARE System provides the capability to better manage the quantity prioritization and presentation of real-time process alarm messages in the control room. The messages are specific, precise and dynamic. The AWARE System can provide a large reduction in the number of messages that the control room staff must address at any one time, thus making the alarm message system a useful tool for the operators during situations that normally produce a high volume of messages as well as improving the clarity of the presentation of process abnormalities during small disturbances. The operating staff is now provided with the basis for a better understanding of the current plant state and for taking the appropriate control actions. (2 refs., 3 figs.)

  10. DTR, Taut Wire System: An alarm barrier with experience

    International Nuclear Information System (INIS)

    Kraft, A.J.

    1986-01-01

    The Taut Wire Fence Alarm System concept was developed and introduced more that fifteen years ago in Israel. A sudden expansion of the nations's border lines, the difficulty to monitor intrusions along those elongated lines and the need for timely as well as accurate armed response to an intrusion attempt dictated the need for an alarming barrier. Traditionally, protection of perimeters was accomplished by the installation of a fence or other type obstacles (man made or natural) and surveillance by manned patrols, fixed observation posts, and/or electronic devices. Defense planners recognized therefore the need for an alarming barrier. A concentrated effort by scientists solved the problem by developing the first Taut Wire Fence Alarm System in a configuration of an alarm barrier. The system was specified to have an extremely low false alarm rate (FAR/NAR), high probability of detection, the capability to follow various terrains, operability in a wide range of environmental conditions, a capability to delay an intruder, ease of installation by unskilled labor, and low maintenance requirements. The authors try here to explain the various constraints and considerations given during the design stages of the Taut Wire Alarm System so as to bring the present magnitude of users to a better understanding of the system's operation

  11. Reactor alarm system development and application issues

    Energy Technology Data Exchange (ETDEWEB)

    Drexler, J E; Oicese, G O [INVAP S.E. (Argentina)

    1997-09-01

    The new hardware and software technologies, and the need in research reactors for assistance systems in operation and maintenance, have given an appropriate background to develop a computer based system named ``Reactor Alarm System`` (RAS). RAS is a software package, user oriented, with emphasis on production, experiments and maintenance goals. It is designed to run on distributed systems conformed with microcomputers under QNX operating system. RAS main features are: (a) Alarm Panel Display; (b) Alarm Page; (c) Alarm Masking and Inhibition; (d) Alarms Color and Attributes; (e) Condition Classification; and (f) Arrangement Presentation. RAS design allows it to be installed as a part of a computer based Supervision and Control System in new installations or retrofit existing reactor instrumentation systems. The analysis of human factors during development stage and successive user feedback from different applications, brought out several RAS improvements: (a) Multiple-copy alarm summaries; (b) Improved alarm handling; (c) Extended dictionary; and (d) Enhanced hardware availability. It has proved successful in providing new capabilities for operators, and also has shown the continuous increase of user-demands, reflecting the expectations placed today on computer-based systems. (author). 6 figs, 1 tabs.

  12. Reactor alarm system development and application issues

    International Nuclear Information System (INIS)

    Drexler, J.E.; Oicese, G.O.

    1997-01-01

    The new hardware and software technologies, and the need in research reactors for assistance systems in operation and maintenance, have given an appropriate background to develop a computer based system named ''Reactor Alarm System'' (RAS). RAS is a software package, user oriented, with emphasis on production, experiments and maintenance goals. It is designed to run on distributed systems conformed with microcomputers under QNX operating system. RAS main features are: a) Alarm Panel Display; b) Alarm Page; c) Alarm Masking and Inhibition; d) Alarms Color and Attributes; e) Condition Classification; and f) Arrangement Presentation. RAS design allows it to be installed as a part of a computer based Supervision and Control System in new installations or retrofit existing reactor instrumentation systems. The analysis of human factors during development stage and successive user feedback from different applications, brought out several RAS improvements: a) Multiple-copy alarm summaries; b) Improved alarm handling; c) Extended dictionary; and d) Enhanced hardware availability. It has proved successful in providing new capabilities for operators, and also has shown the continuous increase of user-demands, reflecting the expectations placed today on computer-based systems. (author). 6 figs, 1 tabs

  13. Design and Optimization of IPM Motor Considering Flux Weakening Capability and Vibration for Electric Vehicle Applications

    Directory of Open Access Journals (Sweden)

    Fangwu Ma

    2018-05-01

    Full Text Available As motor design is key to the development of electric vehicles (EVs and hybrid EVs (HEVs, it has recently become the subject of considerable interest. Interior permanent magnet (IPM motors offer advantages such as high torque density and high efficiency, benefiting from both permanent magnet (PM torque and reluctance torque. However an obvious disadvantage of IPM motors is that operation at high speed involves difficulties in achieving the required flux-weakening capability and low vibration. This study focuses on optimizing the flux-weakening performance and reducing the vibration of an IPM motor for EVs. Firstly, flux-weakening capability, cogging torque, torque ripple, and radical vibration force are analyzed based on the mathematical model. Secondly, three kinds of motors are optimized by the genetic algorithm and analyzed, providing visible insights into the contribution of different rotor structures to the torque characteristics, efficiency, and extended speed range. Thirdly, a slotted rotor configuration is proposed to reduce the torque ripple and radical vibration force. The flux density distributions are discussed, explaining the principle that motors with slotted rotors and stator skew slots have smaller torque ripple and radical vibration force. Lastly, the design and optimization results have been validated against experiments.

  14. Operator Performance Comparison of two VDT-based Alarm Systems

    International Nuclear Information System (INIS)

    Lee, Hyun-Chul; Oh, In-Suk; Sim, Bong-Shick; Koo, In-Soo; Kim, Jeong-Taek; Lee, Ki-Young; Park, Jong-Kyun

    1998-01-01

    This study is carried out to investigate performance differences between two alarm presentation methods from the viewpoint of human factors and to provide items to be improved. One of the alarm display methods considered in this study displays alarm lists on VDT combined with hardwired alarm panels. The other method displays alarms on plant mimic diagrams of VDT. This alarm display method has other features for operator aid with which operator can get detailed information on the activated alarm in the mimic diagrams, and the capability for alarm processing such as alarm reduction and prioritization. To compare the two display methods, a human factor experiment was performed with a plant simulator in the ITF (Integrated Test Facility) that plant operators run for 4 event scenarios. During the experiment, physiological measurements, system and operator action log, and audio/video recordings were collected. Operators subjective opinion was collected as well after the experiment. Time, error rate and situation awareness were major human factor criteria used for the comparison during the analysis stage of the experiment. No statistical significance was found in the results of our statistical comparison analysis. Several findings were identified, however, through the analysis of subjective opinions. (authors)

  15. PT-SAFE: a software tool for development and annunciation of medical audible alarms.

    Science.gov (United States)

    Bennett, Christopher L; McNeer, Richard R

    2012-03-01

    Recent reports by The Joint Commission as well as the Anesthesia Patient Safety Foundation have indicated that medical audible alarm effectiveness needs to be improved. Several recent studies have explored various approaches to improving the audible alarms, motivating the authors to develop real-time software capable of comparing such alarms. We sought to devise software that would allow for the development of a variety of audible alarm designs that could also integrate into existing operating room equipment configurations. The software is meant to be used as a tool for alarm researchers to quickly evaluate novel alarm designs. A software tool was developed for the purpose of creating and annunciating audible alarms. The alarms consisted of annunciators that were mapped to vital sign data received from a patient monitor. An object-oriented approach to software design was used to create a tool that is flexible and modular at run-time, can annunciate wave-files from disk, and can be programmed with MATLAB by the user to create custom alarm algorithms. The software was tested in a simulated operating room to measure technical performance and to validate the time-to-annunciation against existing equipment alarms. The software tool showed efficacy in a simulated operating room environment by providing alarm annunciation in response to physiologic and ventilator signals generated by a human patient simulator, on average 6.2 seconds faster than existing equipment alarms. Performance analysis showed that the software was capable of supporting up to 15 audible alarms on a mid-grade laptop computer before audio dropouts occurred. These results suggest that this software tool provides a foundation for rapidly staging multiple audible alarm sets from the laboratory to a simulation environment for the purpose of evaluating novel alarm designs, thus producing valuable findings for medical audible alarm standardization.

  16. Optical fiber grating vibration sensor for vibration monitoring of hydraulic pump

    Science.gov (United States)

    Zhang, Zhengyi; Liu, Chuntong; Li, Hongcai; He, Zhenxin; Zhao, Xiaofeng

    2017-06-01

    In view of the existing electrical vibration monitoring traditional hydraulic pump vibration sensor, the high false alarm rate is susceptible to electromagnetic interference and is not easy to achieve long-term reliable monitoring, based on the design of a beam of the uniform strength structure of the fiber Bragg grating (FBG) vibration sensor. In this paper, based on the analysis of the vibration theory of the equal strength beam, the principle of FBG vibration tuning based on the equal intensity beam is derived. According to the practical application of the project, the structural dimensions of the equal strength beam are determined, and the optimization design of the vibrator is carried out. The finite element analysis of the sensor is carried out by ANSYS, and the first order resonant frequency is 94.739 Hz. The vibration test of the sensor is carried out by using the vibration frequency of 35 Hz and the vibration source of 50 Hz. The time domain and frequency domain analysis results of test data show that the sensor has good dynamic response characteristics, which can realize the accurate monitoring of the vibration frequency and meet the special requirements of vibration monitoring of hydraulic pump under specific environment.

  17. Advanced non-linear flow-induced vibration and fretting-wear analysis capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Toorani, M.; Pan, L.; Li, R.; Idvorian, N. [Babcock and Wilcox Canada Ltd., Cambridge, Ontario (Canada); Vincent, B.

    2009-07-01

    Fretting wear is a potentially significant degradation mechanism in nuclear steam generators and other shell and tube heat transfer equipment as well. This paper presents an overview of the recently developed code FIVDYNA which is used for the non-linear flow-induced vibration and fretting wear analysis for operating steam generators (OTSG and RSG) and shell-and-tube heat exchangers. FIVDYNA is a non-linear time-history Flow-Induced Vibration (FIV) analysis computer program that has been developed by Babcock and Wilcox Canada to advance the understanding of tube vibration and tube to tube-support interaction. In addition to the dynamic fluid induced forces the program takes into account other tube static forces due to axial and lateral tube preload and thermal interaction loads. The program is capable of predicting the location where the fretting wear is most likely to occur and its magnitude taking into account the support geometry including gaps. FIVDYNA uses the general purpose finite element computer code ABAQUS as its solver. Using ABAQUS gives the user the flexibility to add additional forces to the tube ranging from tube preloads and the support offsets to thermal loads. The forces currently being modeled in FIVDYNA are the random turbulence, steady drag force, fluid-elastic forces, support offset and pre-strain force (axial loads). This program models the vibration of tubes and calculates the structural dynamic characteristics, and interaction forces between the tube and the tube supports. These interaction forces are then used to calculate the work rate at the support and eventually the predicted depth of wear scar on the tube. A very good agreement is found with experiments and also other computer codes. (author)

  18. Expert systems and microwave communication systems alarms processing: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tonn, B.; Goeltz, R.; Purucker, S.

    1987-07-01

    This report presents the results of a feasibility study conducted by Oak Ridge National Laboratory (ORNL) for the Bonneville Power Administration concerning the applicability of Artificial Intelligence (AI) technology to process alarms associated with Bonneville's Microwave Communication System (MCS). Specifically, the discussion focuses on the characteristics of a prototype expert system/database management system (DBMS) configuration capable of intelligently processing alarms, efficiently storing alarm-based historical data, and providing analysis and reporting tools. Such a system has the potential to improve response to critical alarms, increase the information content of a large volume of complicated data, free operators from performing routine analysis, and provide alarm information to operators, field personnel, and management through queries and automatically produced reports.

  19. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  20. False Alarms and Overmonitoring: Major Factors in Alarm Fatigue Among Labor Nurses.

    Science.gov (United States)

    Simpson, Kathleen Rice; Lyndon, Audrey

    2018-06-08

    Nurses can be exposed to hundreds of alarms during their shift, contributing to alarm fatigue. The purposes were to explore similarities and differences in perceptions of clinical alarms by labor nurses caring for generally healthy women compared with perceptions of adult intensive care unit (ICU) and neonatal ICU nurses caring for critically ill patients and to seek nurses' suggestions for potential improvements. Nurses were asked via focus groups about the utility of clinical alarms from medical devices. There was consensus that false alarms and too many devices generating alarms contributed to alarm fatigue, and most alarms lacked clinical relevance. Nurses identified certain types of alarms that they responded to immediately, but the vast majority of the alarms did not contribute to their clinical assessment or planned nursing care. Monitoring only those patients who need it and only those physiologic values that are warranted, based on patient condition, may decrease alarm burden.

  1. Alarm filtering and presentation

    International Nuclear Information System (INIS)

    Bray, M.A.

    1989-01-01

    This paper discusses alarm filtering and presentation in the control room of nuclear and other process control plants. Alarm generation and presentation is widely recognized as a general process control problem. Alarm systems often fail to provide meaningful alarms to operators. Alarm generation and presentation is an area in which computer aiding is feasible and provides clear benefits. Therefore, researchers have developed several computerized alarm filtering and presentation approaches. This paper discusses problems associated with alarm generation and presentation. Approaches to improving the alarm situation and installation issues of alarm system improvements are discussed. The impact of artificial intelligence (AI) technology on alarm system improvements is assessed. (orig.)

  2. Toxicity alarm: Case history

    International Nuclear Information System (INIS)

    Hogan, D.; Retallack, J.

    1993-01-01

    In late fall 1991, the Novacor petrochemical plant near Joffre, Alberta experienced a toxicity alarm, the first since its startup 14 years ago. Fish exposed to a normal toxicity test were stressed within 2 h and showed 100% mortality after 24 h. A history of the events leading up to, during, and after the toxicity alarm is presented. The major effluent sources were three cooling water systems. Although these sources are well characterized, the event causes were not immediately clear. Initial toxic screening indicated that one was very toxic, another moderately toxic, and the third not toxic at all. All three systems utilized the same chemical treatment program to avoid fouling: stabilized phosphates with minor variants. The most toxic of the cooling systems operated at 10-12 cycles, had three chemicals for biocide control, and had three makeup streams. Toxic and nontoxic system characteristics were compared. An in-depth modified toxicity identification and evaluation program was then performed to identify and evaluate the cause of the toxicity alarm for future prevention. The most probable causes of toxicity were identified by elimination. The combination of high numbers of cycles, hydrocarbons in the makeup water, and bromine added as an antifoulant resulted in formation of aromatic bromamines which are capable of causing the toxic condition experienced. 2 tabs

  3. Addressing the alarm analysis barrier - a tool for improving alarm systems

    Energy Technology Data Exchange (ETDEWEB)

    Davey, E C; Basso, R A; Feher, M P [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1996-12-31

    This paper describes a software application tool for the initial specification and maintenance of the thousands of alarms in nuclear and other process control plants. The software program is used by system designers and maintainers to analyze, characterize, record and maintain the alarm information and configuration decisions for an alarm system. The tool provides a comprehensive design and information handling environment for: the existing alarm functions in current CANDU plants; the new alarm processing and presentation concepts developed under CANDU Owners Group (COG) sponsorship that are available to be applied to existing CANDU plants on a retrofit basis; and, the alarm functions to be implemented in new CANDU plants. (author). 3 refs., 1 fig.

  4. Addressing the alarm analysis barrier - a tool for improving alarm systems

    International Nuclear Information System (INIS)

    Davey, E.C.; Basso, R.A.; Feher, M.P.

    1995-01-01

    This paper describes a software application tool for the initial specification and maintenance of the thousands of alarms in nuclear and other process control plants. The software program is used by system designers and maintainers to analyze, characterize, record and maintain the alarm information and configuration decisions for an alarm system. The tool provides a comprehensive design and information handling environment for: the existing alarm functions in current CANDU plants; the new alarm processing and presentation concepts developed under CANDU Owners Group (COG) sponsorship that are available to be applied to existing CANDU plants on a retrofit basis; and, the alarm functions to be implemented in new CANDU plants. (author). 3 refs., 1 fig

  5. Application of neural networks to multiple alarm processing and diagnosis in nuclear power plants

    International Nuclear Information System (INIS)

    Cheon, Se Woo; Chang Soon Heung; Chung, Hak Yeong

    1992-01-01

    This paper presents feasibility studies of multiple alarm processing and diagnosis using neural networks. The back-propagation neural network model is applied to the training of multiple alarm patterns for the identification of failure in a reactor coolant pump (RCP) system. The general mapping capability of the neural network enables to identify a fault easily. The case studies are performed with emphasis on the applicability of the neural network to pattern recognition problems. It is revealed that the neural network model can identify the cause of multiple alarms properly, even when untrained or sensor-failed alarm symptoms are given. It is also shown that multiple failures are easily identified using the symptoms of multiple alarms

  6. Optimized Vibration Chamber for Landslide Sensory and Alarm System

    Science.gov (United States)

    Ismail, Eliza Sabira Binti; Hadi Habaebi, Mohamed; Daoud, Jamal I.; Rafiqul Islam, Md

    2017-11-01

    Landslide is one of natural hazard that is not unfamiliar disaster in Malaysia. Malaysia has experienced this disaster many times since 1969. This natural hazard has become a major research concern for Malaysian government when many people were injured badly and even had been killed. Many previous research works published in the open literature aimed at designing a system that could detect landslide in early stage before the landslide becomes catastrophic. This paper presents the early works on a major work-in-progress landslide early warning system for Malaysian environment. The aim of this system is to develop the most efficiently reliable cost-effective system in which slight earth movements are monitored continuously. The challenge this work aims at is to work with a low budget system that produces efficient performance. Hence, the material used is off-the-shelf. Early design optimization results of the vibration sensor used is quite promising detecting the slightest faint tremors, which are amplified using the best vibration chamber available. It is shown that the choice of proper pipe length and diameter dimensions in combination to a gravel to exaggerate the produced higher sensitivity level noise of 5 dB.

  7. Development of an integrated knowledge-base and its management tool for computerized alarm processing system

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Choi, Seong Soo; Kim, Han Gon; Chang, Soon Heung

    1997-01-01

    For a long time, a number of alarm processing techniques have been researched to reduce the number of actuated alarms for operators to deal with effectively during the abnormal as well as the normal conditions. However, the strategy that the only systems with a few clear technologies should be used as a part of an alarm annunciation system has been adopted considering the effectiveness and the reliability in actual alarm processing systems. Therefore, alarm processing systems have difficult knowledge-base maintenance problems and limited expansion or enhancement defects. To solve these shortcomings, the integrated knowledge-base which can express the general information related to all the alarm processing techniques is proposed and its management tool, Knowledge Input Tool for Alarm (KIT-A) which can handle the data of the knowledge-base efficiently is developed. Since the integrated knowledge-base with KIT-A can manipulate all the alarm information without the modification of alarm processing system itself, it is expected to considerably advance the overall capability of maintenance and enhancement of the alarm processing systems

  8. Bilevel alarm monitoring multiplexer

    International Nuclear Information System (INIS)

    Johnson, C.S.

    1977-06-01

    This report describes the operation of the Bilevel Alarm Monitoring Multiplexer used in the Adaptive Intrusion Data System (AIDS) to transfer and control alarm signals being sent to the Nova 2 computer, the Memory Controlled Data Processor, and its own integral Display Panel. The multiplexer can handle 48 alarm channels and format the alarms into binary formats compatible with the destination of the alarm data

  9. An Investigation of the Vibration Characteristics of the Eurocopter AS35OB Main Rotor Gearbox Under Different Operating Conditions

    National Research Council Canada - National Science Library

    Wang, Wenyi

    2001-01-01

    Different flight conditions can introduce complex changes to the vibration of helicopter transmissions, which may cause a vibration-based in-flight transmission diagnostic system to produce false alarms...

  10. Vibration monitoring of large generator stator and-winding

    International Nuclear Information System (INIS)

    Duffeau, F.; Bernard, P.

    1999-01-01

    Large generators of French Nuclear Power plants are equipped with a standardised vibration monitoring system. The first aim of these new systems is to protect the machines by generating alarms in the control room when predefined vibration thresholds have been over-passed. Secondly, this specially designed instrumentation permits to create a National data base allowing to compare different generators of the same technology. Additionally, statistical methods have been developed in order to 'guess' vibration level at several locations of the stator end-windings, depending on the actual operating parameters of the generator, i.e. reactive and active power load. So this paper presents the general concept of the vibration monitoring of EDF large generator stators and deals with a new method to predict vibrations in different locations under control. (authors)

  11. Development of the effectiveness measure for an advanced alarm system using signal detection theory

    International Nuclear Information System (INIS)

    Park, J.K.; Choi, S.S.; Hong, J.H.; Chang, S.H.

    1997-01-01

    Since many alarms which are activated during major process deviations or accidents in nuclear power plants can result in negative effects for operators, various types of advanced alarm systems that can select important alarms for the identification of process deviation have been developed to reduce the operator's workload. However, the irrelevant selection of important alarms could distract the operator from correct identification of process deviation. Therefore, to evaluate the effectiveness of the advanced alarm system, a tradeoff between the alarm reduction rate (how many alarms are reduced?) and informativeness (how many important alarms that are conducive to identifying process deviation are provided?) of an advanced alarm system should be considered. In this paper, a new measure is proposed to evaluate the effectiveness of an advanced alarm system with regard to the identification of process deviation. Here, the effectiveness measure is the combination of informativeness measure and reduction rate, and the informativeness measure means the information processing capability performed by the advanced alarm system including wrong rejection and wrong acceptance, and it can be calculated using the signal detection theory (SDT). The effectiveness of the prototype alarm system was evaluated using the loss of coolant accident (LOCA) scenario, and the validity of the effectiveness measure was investigated from two types of the operator response, such as the identification accuracy and the operator's preference for the identification of LOCA

  12. Comprehensive smoke alarm coverage in lower economic status homes: alarm presence, functionality, and placement.

    Science.gov (United States)

    Sidman, Elanor A; Grossman, David C; Mueller, Beth A

    2011-08-01

    The objectives of this study are to estimate smoke alarm coverage and adherence with national guidelines in low- to mid-value owner-occupied residences, and to identify resident demographic, behavioral, and building characteristics and other fire and burn safety practices associated with smoke alarm utilization. Baseline visits were conducted with 779 households in King County, Washington, for a randomized trial of smoke alarm functionality. Presence, functionality, features, and location of pre-existing smoke alarms were ascertained by staff observation and testing. Household and building descriptors were collected using questionnaires. Households were classified by presence of smoke alarms, functional alarms, and functional and properly mounted alarms placed in hallways and on each floor but not in recommended avoidance locations. Smoke alarms were present in 89%, and functional units in 78%, of households. Only 6-38% met all assessed functionality and placement recommendations. Homes frequently lacked alarms in any bedrooms or on each floor. Building age, but not renovation status, was associated with all dimensions of smoke alarm coverage; post-1980 constructions were 1.7 times more likely to comply with placement recommendations than were pre-1941 homes (95% CI: 1.1-2.6). Respondent education and race/ethnicity, children wood stoves and fireplaces, number of smoke alarms, recency of smoke alarm testing, carbon monoxide monitors, and fire ladders displayed varying relationships with alarm presence, functionality, and placement. Strategies for maintaining smoke alarms in functional condition and improving compliance with placement recommendations are necessary to achieve universal coverage, and will benefit the majority of households.

  13. Alarming atmospheres

    DEFF Research Database (Denmark)

    Højlund, Marie; Kinch, Sofie

    2014-01-01

    Nurses working in the Neuro-Intensive Care Unit at Aarhus University Hospital lack the tools to prepare children for the alarming atmosphere they will enter when visiting a hospitalised relative. The complex soundscape dominated by alarms and sounds from equipment is mentioned as the main stressor...

  14. Do Scaphoideus titanus (Hemiptera: Cicadellidae) nymphs use vibrational communication?

    Science.gov (United States)

    Chuche, Julien; Thiéry, Denis; Mazzoni, Valerio

    2011-07-01

    Small Auchenorrhyncha use substrate-borne vibrations to communicate. Although this behaviour is well known in adult leafhoppers, so far no studies have been published on nymphs. Here we checked the occurrence of vibrational communication in Scaphoideus titanus (Hemiptera: Cicadellidae) nymphs as a possible explanation of their aggregative distributions on host plants. We studied possible vibratory emissions of isolated and grouped nymphs, as well as their behavioural responses to vibration stimuli that simulated presence of conspecifics, to disturbance noise, white noise and predator spiders. None of our synthetic stimuli or pre-recorded substrate vibrations from nymphs elicited specific vibration responses and only those due to grooming or mechanical contacts of the insect with the leaf were recorded. Thus, S. titanus nymphs showed to not use species-specific vibrations neither for intra- nor interspecific communication and also did not produce alarm vibrations when facing potential predators. We conclude that their aggregative behaviour is independent from a vibrational communication.

  15. An alarm multiplexer communication system

    International Nuclear Information System (INIS)

    Herrera, G.V.

    1986-01-01

    A low cost Alarm Multiplexer Communication System (AMCS) has been developed to perform the security sensor monitoring and control functions and to provide remote relay control capability for integrated security systems. AMCS has a distributed multiplexer/repeater architecture with up to four dual communication loops and dual control computers that guarantee total system operation under any single point failure condition. Each AMCS can control up to 4096 sensors and 2048 remote relays. AMCS reports alarm status information to and is controlled by either one or two Host computers. This allows for independent operation of primary and backup security command centers. AMCS communicates with the Host computers over an asynchronous serial communication link and has a message protocol which allows AMCS to fully recover from lost messages or large blocks of data communication errors. This paper describes the AMCS theory of operation, AMCS fault modes, and AMCS system design methodology. Also, cost and timing information is presented. AMCS is being used and considered for several DOE and DOD facilities

  16. Advances in software development for intelligent interfaces for alarm and emergency management consoles

    International Nuclear Information System (INIS)

    Moseley, M.R.; Olson, C.E.

    1986-01-01

    Recent advances in technology allow features like voice synthesis, voice and speech recognition, image understanding, and intelligent data base management to be incorporated in computer driven alarm and emergency management information systems. New software development environments make it possible to do rapid prototyping of custom applications. Three examples using these technologies are discussed. (1) Maximum use is made of high-speed graphics and voice synthesis to implement a state-of-the-art alarm processing and display system with features that make the operator-machine interface efficient and accurate. Although very functional, this system is not portable or flexible; the software would have to be substantially rewritten for other applications. (2) An application generator which has the capability of ''building'' a specific alarm processing and display application in a matter of a few hours, using the site definition developed in the security planning phase to produce the custom application. This package is based on a standardized choice of hardware, within which it is capable of building a system to order, automatically constructing graphics, data tables, alarm prioritization rules, and interfaces to peripherals. (3) A software tool, the User Interface Management System (UIMS), is described which permits rapid prototyping of human-machine interfaces for a variety of applications including emergency management, alarm display and process information display. The object-oriented software of the UIMS achieves rapid prototyping of a new interface by standardizing to a class library of software objects instead of hardware objects

  17. Security alarm communication and display systems development

    International Nuclear Information System (INIS)

    Waddoups, I.G.

    1990-01-01

    Sandia National Laboratories (SNL) has, as lead Department of Energy (DOE) physical security laboratory, developed a variety of alarm communication and display systems for DOE and Department of Defense (DOD) facilities. This paper briefly describes some of the systems developed and concludes with a discussion of technology relevant to those currently designing, developing, implementing, or procuring such a system. Development activities and the rapid evolution of computers over the last decade have resulted in a broad variety of capabilities to support most security system communication and display needs. The major task in selecting a system is becoming familiar with these capabilities and finding the best match to a specific need

  18. Recommendations to alarm systems and lessons learned on alarm system implementation

    International Nuclear Information System (INIS)

    Soerenssen, Aimar; Veland, Oeystein; Farbrot, Jan Erik; Kaarstad, Magnhild; Seim, Lars Aage; Foerdestroemmen, Nils; Bye, Andreas

    2001-11-01

    Alarm systems have been of major concern within complex industrial processes for many years. Within the nuclear community, the TMI accident in 1979 was the first really serious event that showed also the importance of the man-machine aspects of the systems in general, and the alarm system in particular. The OECD Halden Reactor Project has been working with alarm systems since 1974. This report is an attempt to gather some of the knowledge that has been accumulated during the years in Halden, both in research and also in bilateral projects. Bilateral projects within this field have provided a practical basis of knowledge.A major part of this report consists of a set of recommendations, which reflect HRP's current understanding of how an alarm system should work. There are also recommendations on design methods. But also other issues are included, as system development and implementation experience, and experimental knowledge on the performance of alarm systems. Some open issues are also discussed. (Author). 54 refs., 15 figs

  19. Alarm annunciation in a graphical environment

    International Nuclear Information System (INIS)

    Adams, D.G.

    1994-01-01

    Well-designed graphical user interfaces, such as Microsoft reg-sign Windows trademark or UNIX trademark--based X-Windows reg-sign, provide a capability for enhanced display of security alarm information. Conversely, a poorly designed interface can quickly overwhelm an operator. This paper describes types of graphical information that can be displayed and offers guidance on how to best display that information. Limits are proposed for the complexity of the user interface, and guidelines are suggested for the display of maps and sensors

  20. Alarm processing - Ways to the future

    Energy Technology Data Exchange (ETDEWEB)

    Pirus, D [EDF - Septen Service Etudes et Projets Thermiques et Nucleires, Villeurbanne Cedex (France)

    1997-09-01

    After a brief presentation of the main characteristics an efficient alarm system should have, a presentation of the N4 alarm processing and presentation is described in terms of reduction in alarm occurrence, alarm handling and operator presentation. The EDF experiments on the future alarm processing expected for the next generation of the French nuclear plants are then presented. This alarm system will manage the alarms functionally in order to present to the operators the real consequences on the whole plant of a dedicated alarm and try to imbed deeply the alarm presentation within the operating formats and the procedures. (author).

  1. Alarm processing - Ways to the future

    International Nuclear Information System (INIS)

    Pirus, D.

    1997-01-01

    After a brief presentation of the main characteristics an efficient alarm system should have, a presentation of the N4 alarm processing and presentation is described in terms of reduction in alarm occurrence, alarm handling and operator presentation. The EDF experiments on the future alarm processing expected for the next generation of the French nuclear plants are then presented. This alarm system will manage the alarms functionally in order to present to the operators the real consequences on the whole plant of a dedicated alarm and try to imbed deeply the alarm presentation within the operating formats and the procedures. (author)

  2. A joint time-invariant wavelet transform and kurtosis approach to the improvement of in-line oil debris sensor capability

    International Nuclear Information System (INIS)

    Fan, X; Liang, M; Yeap, T

    2009-01-01

    In-line oil debris sensors are important devices for the detection of machinery failures. However, two key issues remain to be addressed to more effectively make use of the existing oil debris sensors: the responsiveness to early machine failures and false alarms. The responsiveness level depends on the size of the debris that can be detected by an oil debris sensor. The detectable particle size in turn is mainly limited by the background noise. The false alarms are often caused by spurious impulses such as vibration-like signals. The challenge of improving the responsiveness and reducing false alarms lies in the very weak particle signals and their similarity to spurious signals. In this paper, a joint time-invariant wavelet transform and kurtosis analysis method is proposed to address the two issues simultaneously. The proposed method has been tested by extracting signatures of ultra-small metal particles from background noise and a wide range of simulated vibration-like and real vibration signals. Our test results have demonstrated that the proposed method can effectively detect very weak particle signals buried in strong background noise and eliminate vibration-like spurious signals. The implementation of the proposed method will substantially enhance many existing oil debris sensors

  3. Honey Bee Inhibitory Signaling Is Tuned to Threat Severity and Can Act as a Colony Alarm Signal.

    Science.gov (United States)

    Tan, Ken; Dong, Shihao; Li, Xinyu; Liu, Xiwen; Wang, Chao; Li, Jianjun; Nieh, James C

    2016-03-01

    Alarm communication is a key adaptation that helps social groups resist predation and rally defenses. In Asia, the world's largest hornet, Vespa mandarinia, and the smaller hornet, Vespa velutina, prey upon foragers and nests of the Asian honey bee, Apis cerana. We attacked foragers and colony nest entrances with these predators and provide the first evidence, in social insects, of an alarm signal that encodes graded danger and attack context. We show that, like Apis mellifera, A. cerana possesses a vibrational "stop signal," which can be triggered by predator attacks upon foragers and inhibits waggle dancing. Large hornet attacks were more dangerous and resulted in higher bee mortality. Per attack at the colony level, large hornets elicited more stop signals than small hornets. Unexpectedly, stop signals elicited by large hornets (SS large hornet) had a significantly higher vibrational fundamental frequency than those elicited by small hornets (SS small hornet) and were more effective at inhibiting waggle dancing. Stop signals resulting from attacks upon the nest entrance (SS nest) were produced by foragers and guards and were significantly longer in pulse duration than stop signals elicited by attacks upon foragers (SS forager). Unlike SS forager, SS nest were targeted at dancing and non-dancing foragers and had the common effect, tuned to hornet threat level, of inhibiting bee departures from the safe interior of the nest. Meanwhile, nest defenders were triggered by the bee alarm pheromone and live hornet presence to heat-ball the hornet. In A. cerana, sophisticated recruitment communication that encodes food location, the waggle dance, is therefore matched with an inhibitory/alarm signal that encodes information about the context of danger and its threat level.

  4. Analysis of the performance capability of an infrared interior intrusion detector

    International Nuclear Information System (INIS)

    Dunn, D.R.

    1977-01-01

    Component performances are required by the LLL assessment procedure for material control and accounting (MC and A) systems. Monitors are an example of an MC and A component whose functions are to process measurements or observations for purposes of detecting abnormalities. This report develops a methodology for characterizing the performance of a class of infrared (IR) interior intrusion monitors or detectors. The methodology is developed around a specific commercial IR detector, the InfrAlarm, manufactured by Barnes Engineering Company (Models 19-124 and 19-115A). Statistical detection models for computing probabilities of detection and false alarms were derived, and the performance capability of the InfrAlarm IR detector was shown using these measures. The results obtained in the performance analysis show that the detection capability of the InfrAlarm is excellent (approx. 1), with very low false alarm rates, for a wide range in target characteristics. These results should be representative and particularly for non-hostile environments

  5. The Best Ever Alarm System Toolkit

    International Nuclear Information System (INIS)

    Kasemir, Kay; Chen, Xihui; Danilova, Ekaterina N.

    2009-01-01

    Learning from our experience with the standard Experimental Physics and Industrial Control System (EPICS) alarm handler (ALH) as well as a similar intermediate approach based on script-generated operator screens, we developed the Best Ever Alarm System Toolkit (BEAST). It is based on Java and Eclipse on the Control System Studio (CSS) platform, using a relational database (RDB) to store the configuration and log actions. It employs a Java Message Service (JMS) for communication between the modular pieces of the toolkit, which include an Alarm Server to maintain the current alarm state, an arbitrary number of Alarm Client user interfaces (GUI), and tools to annunciate alarms or log alarm related actions. Web reports allow us to monitor the alarm system performance and spot deficiencies in the alarm configuration. The Alarm Client GUI not only gives the end users various ways to view alarms in tree and table, but also makes it easy to access the guidance information, the related operator displays and other CSS tools. It also allows online configuration to be simply modified from the GUI. Coupled with a good 'alarm philosophy' on how to provide useful alarms, we can finally improve the configuration to achieve an effective alarm system.

  6. Optimal Alarm Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — An optimal alarm system is simply an optimal level-crossing predictor that can be designed to elicit the fewest false alarms for a fixed detection probability. It...

  7. A revival of the alarm system: Making the alarm list useful during incidents

    International Nuclear Information System (INIS)

    Larsson, J. E.; Oehman, B.; Calzada, A.; Nihlwing, C.; Jokstad, H.; Kristianssen, L. I.; Kvalem, J.; Lind, M.

    2006-01-01

    In control rooms there are often problems with information overload, which means that the operators may receive more information than they are able to interpret. The most serious information overload occurs in two types of situations. The first is when the operating state of the plant changes, which often gives raise to a shower of alarms and events. Such an alarm shower is expected, but can be dangerous, because it may hide other alarms originating from unrelated faults. The second problem occurs when a fault causes several consequential faults, leading to a so-called alarm cascade. Because the alarms seldom arrive in correct time order, it can be very difficult to analyze such a cascade, and the information overload occurs in exactly the moment when a potentially dangerous situation starts. In an ongoing project, GoalArt and IFE are cooperating in testing and evaluating GoalArt's methods for alarm reduction and root cause analysis. The testing comprises two specific algorithms, root cause analysis and state-based alarm priority. The GoalArt system has been integrated with the HAMBO simulator so that operators can evaluate the algorithms on-line. (authors)

  8. Integrated alarm annunciation and entry control systems -- Survey results

    International Nuclear Information System (INIS)

    Clever, J.J.; Arakaki, L.H.; Monaco, F.M.; Juarros, L.E.; Quintana, G.R.

    1993-10-01

    This report provides the results and analyses of a detailed survey undertaken in Summer 1993 to address integrated intrusion detection alarm annunciation and entry control system issues. This survey was undertaken as a first attempt toward beginning to answer questions about integrated systems and commercial capabilities to meet or partially meet US Department of Energy (DOE) site needs

  9. Alarm management for storage and transportation terminals; Gerenciamento de alarmes para terminais de transferencia e estocagem

    Energy Technology Data Exchange (ETDEWEB)

    Loureiro, Patricia [PETROBRAS, Rio de Janeiro, RJ (Brazil); Feldman, Rafael Noac [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2005-07-01

    Recently, in many industrial segments, it has been taken into account the issues related to the high amount of alarms that are announced in the control rooms, even if the industrial process is under normal conditions. Recent studies and surveys have shown that the three major problems related to it are: alarms that remain active during normal operation; alarms that remain chattering during an operational period; the phenomenon called Alarm flood, that occurs when an extensive amount of alarms is announced and the operator does not have enough time to take effective actions. In order to reduce or to eliminate the two above mentioned causes, alarm analysis and housekeeping, called Alarm Rationalization, have been efficient in major cases, because such facts occur mainly due to inadequate limits definition and/or equipment and instruments out of service or in maintenance. Such alarms are called in the literature as bad-actors or villains, and their occurrences may reach up to 50% of the daily total amount of alarms. This paper aims to present the main results of a project named Alarm Management for Transfer and Storage Terminals. The project development is based on two different terminal surveys, in order not only to identify the most frequent causes of undesirable alarms, but also to generate design standards. The main phases of the project are: alarm rationalization based on bad-actors detection; generate a set of design and operation standards; generate an Alarm Philosophy document for the Terminals. (author)

  10. Inferring Gear Damage from Oil-Debris and Vibration Data

    Science.gov (United States)

    Dempsey, Paula

    2006-01-01

    A system for real-time detection of surface-fatigue-pitting damage to gears for use in a helicopter transmission is based on fuzzy-logic used to fuse data from sensors that measure oil-borne debris, referred to as "oil debris" in the article, and vibration signatures. A system to detect helicopter-transmission gear damage is beneficial because the power train of a helicopter is essential for propulsion, lift, and maneuvering, hence, the integrity of the transmission is critical to helicopter safety. To enable detection of an impending transmission failure, an ideal diagnostic system should provide real-time monitoring of the "health" of the transmission, be capable of a high level of reliable detection (with minimization of false alarms), and provide human users with clear information on the health of the system without making it necessary for them to interpret large amounts of sensor data.

  11. Recommended practice for the design of a computer driven Alarm Display Facility for central control rooms of nuclear power generating stations

    International Nuclear Information System (INIS)

    Ben-Yaacov, G.

    1984-01-01

    This paper's objective is to explain the process by which design can prevent human errors in nuclear plant operation. Human factor engineering principles, data, and methods used in the design of computer driven alarm display facilities are discussed. A ''generic'', advanced Alarm Display Facility is described. It considers operator capabilities and limitations in decision-making processes, response dynamics, and human memory limitations. Highlighted are considerations of human factor criteria in the designing and layout of alarm displays. Alarm data sources are described, and their use within the Alarm Display Facility are illustrated

  12. Honey Bee Inhibitory Signaling Is Tuned to Threat Severity and Can Act as a Colony Alarm Signal.

    Directory of Open Access Journals (Sweden)

    Ken Tan

    2016-03-01

    Full Text Available Alarm communication is a key adaptation that helps social groups resist predation and rally defenses. In Asia, the world's largest hornet, Vespa mandarinia, and the smaller hornet, Vespa velutina, prey upon foragers and nests of the Asian honey bee, Apis cerana. We attacked foragers and colony nest entrances with these predators and provide the first evidence, in social insects, of an alarm signal that encodes graded danger and attack context. We show that, like Apis mellifera, A. cerana possesses a vibrational "stop signal," which can be triggered by predator attacks upon foragers and inhibits waggle dancing. Large hornet attacks were more dangerous and resulted in higher bee mortality. Per attack at the colony level, large hornets elicited more stop signals than small hornets. Unexpectedly, stop signals elicited by large hornets (SS large hornet had a significantly higher vibrational fundamental frequency than those elicited by small hornets (SS small hornet and were more effective at inhibiting waggle dancing. Stop signals resulting from attacks upon the nest entrance (SS nest were produced by foragers and guards and were significantly longer in pulse duration than stop signals elicited by attacks upon foragers (SS forager. Unlike SS forager, SS nest were targeted at dancing and non-dancing foragers and had the common effect, tuned to hornet threat level, of inhibiting bee departures from the safe interior of the nest. Meanwhile, nest defenders were triggered by the bee alarm pheromone and live hornet presence to heat-ball the hornet. In A. cerana, sophisticated recruitment communication that encodes food location, the waggle dance, is therefore matched with an inhibitory/alarm signal that encodes information about the context of danger and its threat level.

  13. Statistical evaluation of vibration analysis techniques

    Science.gov (United States)

    Milner, G. Martin; Miller, Patrice S.

    1987-01-01

    An evaluation methodology is presented for a selection of candidate vibration analysis techniques applicable to machinery representative of the environmental control and life support system of advanced spacecraft; illustrative results are given. Attention is given to the statistical analysis of small sample experiments, the quantification of detection performance for diverse techniques through the computation of probability of detection versus probability of false alarm, and the quantification of diagnostic performance.

  14. Alarm-Processing in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Otazo, J; Fernandez, R

    2000-01-01

    Information overload due to the activation of a great number of alarms in a short time is a common problem for the operator in the control room of a industrial plant, mainly in complex process like the nuclear power plants.The problem is the conventional conception of the alarm system, that defines each alarm like a separated and independent entity of the global situation of the plant.A direct consequence is the generation of multiple alarms during a significative disturbance in the process, being most of them redundant and irrelevant to the actual process state wich involves an extra load to the operator, who wastes time in acting selecting the important alarms of the group that appears or lead to a an erroneous action.The present work first describes the techniques developed in the last years to attack the avalanche of alarms problem.Later we present our approach to alarm-processing: an expert system as alarm-filter.Our objective is collect in the system the state of the art in the development of advanced alarm systems, offering an improvement of the information flow to the operators through the suppression of nonsignificant alarms and a structured visualization of the process state.Such support is important during a disturbance for the identification of plant state, diagnosis, consequence prediction and corrective actions.The system is arranged in three stages: alarm-generation, alarm-filter and alarm-presentation.The alarm-generation uses conventional techniques or receives them from an external system.The alarm-filter uses suppression techniques based on: irrelevance analysis with the operation mode and the state of components, causal reasoning and static importance analysis.The alarm presentation is made through a structured way using a priority scheme with three level.The knowledge representation of each alarm is based on frames and a graph of alarms for global knowledge, where the connections between nodes represent causal and irrelevance relations

  15. Security Alarm for Motorcycle

    Directory of Open Access Journals (Sweden)

    Ismail Ismail

    2015-11-01

    Full Text Available A security alarm for motorcycle has been developed. This equipment consists of two parts. Part one is as a remote control, where it produces a radio signal with frequency of 37.5 MHz to turn on (activate or to turn off alarm. Part two consists of sensor, receiver to receive signal from part one, and alarm. This part two will be attached to motorcycle while part one will be kept as a key by the owner of motorcycle. This equipment has been tested in the laboratory and it worked well. When part two is activated by pushing the “set button” in part one, then any movement of part two (as a movement of motor cycle by about 20 cm from initial position will cause the alarm sounds continuously. The alarm will be off whenever the “reset button” in part one is pushed. Part one (a remote control can activate part two with a maximum of twelve meter separation apart. This shows that the equipment can be used as a security alarm to prevent the motorcycle to be stolen in the future.

  16. Advances in software development for intelligent interfaces for alarm and emergency management consoles

    International Nuclear Information System (INIS)

    Moseley, M.R.; Olson, C.E.

    1986-01-01

    Recent advances in technology allow features like voice synthesis, voice and speech recognition, image understanding, and intelligent data base management to be incorporated in computer driven alarm and emergency management information systems. New software development environments make it possible to do rapid prototyping of custom applications. Three examples using these technologies are discussed. 1) Maximum use is made of high-speed graphics and voice synthesis to implement a state-of-the-art alarm processing and display system with features that make the operator-machine interface efficient and accurate. 2) An application generator which has the capability of ''building'' a specific alarm processing and display application in a matter of a few hours, using the site definition developed in the security planning phase to produce the custom application. 3) A software tool, is described which permits rapid prototyping of human-machine interfaces for a variety of applications including emergency management, alarm display and process information display

  17. Transportable criticality alarm system

    International Nuclear Information System (INIS)

    Clem, W.E.

    1988-09-01

    The Transportable Criticality Alarm System was developed at the Hanford Site in 1982 to comply with the requirements of US Department of Energy Order DOE 5480.1, 12/18/80, and ANSI/ANS-8.3- 1979. The portable unit that it replaced failed to comply with the new requirements in that it did not provide the necessary warning of malfunctions, nor did it provide the Hanford Site standard criticality alarm signal. Modern technology allowed the Transportable Criticality Alarm System to comply with the criticality requirements cited and to incorporate other features that make it more usable, maintainable, and reliable. The Transportable Criticality Alarm System (TCAS) provides temporary criticality coverage in manned areas where the facility criticality alarm system is not operable. This gamma radiation-sensitive system has been in use for the past 6 yr at the Hanford Site. 2 refs., 4 figs., 1 tab

  18. Customized DSP-based vibration measurement for wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    LaWhite, N.E.; Cohn, K.E. [Second Wind Inc., Somerville, MA (United States)

    1996-12-31

    As part of its Advanced Distributed Monitoring System (ADMS) project funded by NREL, Second Wind Inc. is developing a new vibration measurement system for use with wind turbines. The system uses low-cost accelerometers originally designed for automobile airbag crash-detection coupled with new software executed on a Digital Signal Processor (DSP) device. The system is envisioned as a means to monitor the mechanical {open_quotes}health{close_quotes} of the wind turbine over its lifetime. In addition the system holds promise as a customized emergency vibration detector. The two goals are very different and it is expected that different software programs will be executed for each function. While a fast Fourier transform (FFT) signature under given operating conditions can yield much information regarding turbine condition, the sampling period and processing requirements make it inappropriate for emergency condition monitoring. This paper briefly reviews the development of prototype DSP and accelerometer hardware. More importantly, it reviews our work to design prototype vibration alarm filters. Two-axis accelerometer test data from the experimental FloWind vertical axis wind turbine is analyzed and used as a development guide. Two levels of signal processing are considered. The first uses narrow band pre-processing filters at key fundamental frequencies such as the 1P, 2P and 3P. The total vibration energy in each frequency band is calculated and evaluated as a possible alarm trigger. In the second level of signal processing, the total vibration energy in each frequency band is further decomposed using the two-axis directional information. Directional statistics are calculated to differentiate between linear translations and circular translations. After analyzing the acceleration statistics for normal and unusual operating conditions, the acceleration processing system described could be used in automatic early detection of fault conditions. 9 figs.

  19. Object oriented design in the AGSDCS alarm system

    International Nuclear Information System (INIS)

    Morris, J.T.

    1994-01-01

    The alarm subsystem of the Alternating Gradient Synchrotron Distributed Control System (AGSDCS) has been redesigned to enhance reliability, flexibility, and ease of maintenance. The alarm system is functionally divided into Alarm Generators, Alarm Displays, and a central Alarm Receiver. The task was simplified by defining a set of C++ classes that could be reused by all components of the alarm system. The AlarmData class represents instances of alarm conditions. The AlarmFilter class is used by both the Alarm Receiver and Alarm Displays to select the alarms that are of interest to a particular user. The AlarmDatabase class is used by the Alarm Receiver to manage the central alarm database. The Alarm Displays use the AlarmDatabase class to manage the local database representing the alarms on their screens. ((orig.))

  20. A vacuum microgripping tool with integrated vibration releasing capability

    Energy Technology Data Exchange (ETDEWEB)

    Rong, Weibin; Fan, Zenghua, E-mail: zenghua-fan@163.com; Wang, Lefeng; Xie, Hui; Sun, Lining [State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang (China)

    2014-08-01

    Pick-and-place of micro-objects is a basic task in various micromanipulation demands. Reliable releasing of micro-objects is usually disturbed due to strong scale effects. This paper focuses on a vacuum micro-gripper with vibration releasing functionality, which was designed and assembled for reliable micromanipulation tasks. Accordingly, a vibration releasing strategy of implementing a piezoelectric actuator on the vacuum microgripping tool is presented to address the releasing problem. The releasing mechanism was illustrated using a dynamic micro contact model. This model was developed via theoretical analysis, simulations and pull-off force measurement using atomic force microscopy. Micromanipulation experiments were conducted to verify the performance of the vacuum micro-gripper. The results show that, with the assistance of the vibration releasing, the vacuum microgripping tool can achieve reliable release of micro-objects. A releasing location accuracy of 4.5±0.5 μm and a successful releasing rate of around 100% (which is based on 110 trials) were achieved for manipulating polystyrene microspheres with radius of 35–100 μm.

  1. A vacuum microgripping tool with integrated vibration releasing capability

    International Nuclear Information System (INIS)

    Rong, Weibin; Fan, Zenghua; Wang, Lefeng; Xie, Hui; Sun, Lining

    2014-01-01

    Pick-and-place of micro-objects is a basic task in various micromanipulation demands. Reliable releasing of micro-objects is usually disturbed due to strong scale effects. This paper focuses on a vacuum micro-gripper with vibration releasing functionality, which was designed and assembled for reliable micromanipulation tasks. Accordingly, a vibration releasing strategy of implementing a piezoelectric actuator on the vacuum microgripping tool is presented to address the releasing problem. The releasing mechanism was illustrated using a dynamic micro contact model. This model was developed via theoretical analysis, simulations and pull-off force measurement using atomic force microscopy. Micromanipulation experiments were conducted to verify the performance of the vacuum micro-gripper. The results show that, with the assistance of the vibration releasing, the vacuum microgripping tool can achieve reliable release of micro-objects. A releasing location accuracy of 4.5±0.5 μm and a successful releasing rate of around 100% (which is based on 110 trials) were achieved for manipulating polystyrene microspheres with radius of 35–100 μm

  2. Central alarm system replacement in NPP Krsko

    International Nuclear Information System (INIS)

    Cicvaric, D.; Susnic, M.; Djetelic, N.

    2004-01-01

    Current NPP Krsko central alarm system consists of three main segments. Main Control Board alarm system (BETA 1000), Ventilation Control Board alarm system (BETA 1000) and Electrical Control Board alarm system (BETA 1100). All sections are equipped with specific BetaTone audible alarms and silence, acknowledge as well as test push buttons. The main reason for central alarm system replacement is system obsolescence and problems with maintenance, due to lack of spare parts. Other issue is lack of system redundancy, which could lead to loss of several Alarm Light Boxes in the event of particular power supply failure. Current central alarm system does not provide means of alarm optimization, grouping or prioritization. There are three main options for central alarm system replacement: Conventional annunciator system, hybrid annunciator system and advanced alarm system. Advanced alarm system implementation requires Main Control Board upgrade, integration of process instrumentation and plant process computer as well as long time for replacement. NPP Krsko has decided to implement hybrid alarm system with patchwork approach. The new central alarm system will be stand alone, digital, with advanced filtering and alarm grouping options. Sequence of event recorder will be linked with plant process computer and time synchronized with redundant GPS signal. Advanced functions such as link to plant procedures will be implemented with plant process computer upgrade in outage 2006. Central alarm system replacement is due in outage 2004.(author)

  3. A new diagnosis method using alarm annunciation for nuclear power plants

    International Nuclear Information System (INIS)

    Ozaki, Yoshihiko; Suda, Kazunori; Ozawa, Kenji

    1997-01-01

    We discuss the methodology diversity for diagnosis reasoning in an autonomous operation system, and propose a new diagnosis method using an alarm annunciation system. The combination of annunciated alarms is expected to be peculiar to the anomalous phenomenon or accident. Moreover, as the state of affairs is developing, each appearance of the pattern is changing with time peculiarly to each anomaly or accident. The matter is utilized for the new diagnosis method. The patterns of annunciated alarms with progress of the events are prepared in advance under the condition of the anomalies or accidents by use of a plant simulator. The diagnostic reasoning can be done by comparing the obtained combination of annunciated alarms with the reference templates by using pattern matching method. On the other hand, we have another method, called COBWEB used for conceptual classification in cognitive science, to reason for diagnosis. We have carried out the experiments using the loop type LMFBR plant simulator to obtain the various combinations of annunciated alarms with progress of the events under the conditions of anomalies and accidents. The examined cases were related to the anomalies and accidents in the water/steam system of the LMFBR power plant. The simulation examination showed that each change of the pattern of annunciated alarms is specific to each anomaly or accident, and we have applied the pattern matching technique and COBWEB methods into the diagnostic reasoning using annunciated alarms. We could show the capability of these two methods to reason and focus among various candidates of causes of anomalies with gradually improved conviction degree as time passes from the occurrence of anomalies. It was also confirmed that these methods are effective in diagnosis reasoning as a way the operators are doing the diagnosis reasoning in existing plants. (author)

  4. Construction of a Vibration Monitoring System for HANARO's Rotating Machinery and Analysis of Pump Vibration Signals

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo; Yoon, Doo Byung

    2005-01-01

    HANARO is an open-tank-in-pool type research reactor with a thermal power of 30MW. In order to remove the heat generated by the reactor core and the reflector vessel, primary cooling pumps and reflector cooling pumps circulate coolant. These pumps are installed at the RCI(Reactor Concrete Island) which is covered by heavy concrete hatches. For the prevention of an abnormal operation of these pumps in the RCI, it is necessary to construct a vibration monitoring system that provides an alarm signal to the reactor control room when the rotating speed or the vibration level exceeds the allowable limit. The first objective of this work is to construct a vibration monitoring system for HANARO's rotating machinery. The second objective is to verify the possibility of condition monitoring of the rotating machinery. To construct a vibration monitoring system, as a first step, the standards and references related to the vibration monitoring system were investigated. In addition, to determine the number and the location of sensors that can effectively characterize the overall vibration of a pump, the vibration of the primary cooling pumps and the reflector cooling pumps were measured. Based on these results, detailed construction plans for the vibration monitoring system for HANARO were established. Then, in accordance with the construction plans, the vibration monitoring system for HANARO's rotating machinery was manufactured and installed at HANARO. To achieve the second objective, FFT analysis and bearing fault detection of the measured vibration signals were performed. The analysis results demonstrate that the accelerometers mounted at the bearing locations of the pumps can effectively monitor the pump condition

  5. Criticality alarm device

    International Nuclear Information System (INIS)

    Kasai, Kenji.

    1994-01-01

    The device of the present invention is utilized, for example, to a reprocessing facility for storing and processing nuclear fuels and measures and controls the nuclear fuel assembly system so as not to exceed criticality. That is, a conventional criticality alarm device applies a predetermined processing to neutron fluxes generated from a nuclear fuel assembly system containing nuclear fuels and outputs an alarm. The device of the present invention comprises (1) a neutron flux supply source for increasing and decreasing neutron fluxes periodically and supplying them to nuclear fuel assemblies, (2) a detector for detecting neutron fluxes in the nuclear fuel assemblies, (3) a critical state judging section for judging the critical state of the nuclear fuel assemblies based on the periodically changing signals obtained from the detector (2) and (4) an alarm section for outputting criticality alarms depending on the result of the judgement. The device of the present invention can accurately recognize the critical state of the nuclear fuel assembly system and can forecast reaching of the nuclear fuel assembly to criticality or prompt neutron critical state. (I.S.)

  6. Fundamental Principles of Alarm Design

    DEFF Research Database (Denmark)

    Us, Tolga; Jensen, Niels; Lind, Morten

    2011-01-01

    Traditionally alarms are designed on the basis of empirical guidelines rather than on a sound scientific framework rooted in a theoretical foundation for process and control system design. This paper proposes scientific principles and a methodology for design of alarms based on a functional...... be applied to any engineering system which can be modeled by MFM. The methodology provides a set of alarms which can facilitate event interpretation and operator support for abnormal situation management. The proposed design methodology provides the information content of the alarms, but does not deal...

  7. The CANDU alarm analysis tool (CAAT)

    Energy Technology Data Exchange (ETDEWEB)

    Davey, E C; Feher, M P; Lupton, L R [Control Centre Technology Branch, ON (Canada)

    1997-09-01

    AECL undertook the development of a software tool to assist alarm system designers and maintainers based on feedback from several utilities and design groups. The software application is called the CANDU Alarm Analysis Tool (CAAT) and is being developed to: Reduce by one half the effort required to initially implement and commission alarm system improvements; improve the operational relevance, consistency and accuracy of station alarm information; record the basis for alarm-related decisions; provide printed reports of the current alarm configuration; and, make day-to-day maintenance of the alarm database less tedious and more cost-effective. The CAAT assists users in accessing, sorting and recording relevant information, design rules, decisions, and provides reports in support of alarm system maintenance, analysis of design changes, or regulatory inquiry. The paper discusses the need for such a tool, outlines the application objectives and principles used to guide tool development, describes the how specific tool features support user design and maintenance tasks, and relates the lessons learned from early application experience. (author). 4 refs, 2 figs.

  8. The CANDU alarm analysis tool (CAAT)

    International Nuclear Information System (INIS)

    Davey, E.C.; Feher, M.P.; Lupton, L.R.

    1997-01-01

    AECL undertook the development of a software tool to assist alarm system designers and maintainers based on feedback from several utilities and design groups. The software application is called the CANDU Alarm Analysis Tool (CAAT) and is being developed to: Reduce by one half the effort required to initially implement and commission alarm system improvements; improve the operational relevance, consistency and accuracy of station alarm information; record the basis for alarm-related decisions; provide printed reports of the current alarm configuration; and, make day-to-day maintenance of the alarm database less tedious and more cost-effective. The CAAT assists users in accessing, sorting and recording relevant information, design rules, decisions, and provides reports in support of alarm system maintenance, analysis of design changes, or regulatory inquiry. The paper discusses the need for such a tool, outlines the application objectives and principles used to guide tool development, describes the how specific tool features support user design and maintenance tasks, and relates the lessons learned from early application experience. (author). 4 refs, 2 figs

  9. Fault tolerant microcomputer based alarm annunciator for Dhruva reactor

    International Nuclear Information System (INIS)

    Chandra, A.K.

    1988-01-01

    The Dhruva alarm annunciator displays the status of 624 alarm points on an array of display windows using the standard ringback sequence. Recognizing the need for a very high availability, the system is implemented as a fault tolerant configuration. The annunciator is partitioned into three identical units; each unit is implemented using two microcomputers wired in a hot standby mode. In the event of one computer malfunctioning, the standby computer takes over control in a bouncefree transfer. The use of microprocessors has helped built-in flexibility in the system. The system also provides built-in capability to resolve the sequence of occurrence of events and conveys this information to another system for display on a CRT. This report describes the system features, fault tolerant organisation used and the hardware and software developed for the annunciation function. (author). 8 figs

  10. Some points of advanced alarm system design

    International Nuclear Information System (INIS)

    Hollo, E.

    1977-01-01

    A description of some of the more relevant questions relating to advanced alarm systems for nuclear power plant installations. The development of such alarm systems embodies three main tasks: development of formal alarm handling methods, design of alarm patterns, development of alarm analysis systems. The major aspects of these tests are dealt with and the close relation between the alarm analysis and the plant disturbance analysis procedure is emphasized. (author)

  11. Evaluating alternative responses to safeguards alarms

    International Nuclear Information System (INIS)

    Al-Ayat, R.A.; Judd, B.R.; McCord, R.K.

    1982-01-01

    This paper describes a quantitative approach to help evaluate and respond to safeguards alarms. These alarms may be generated internally by a facility's safeguards systems or externally by individuals claiming to have stolen special nuclear material (SNM). This approach can be used to identify the most likely cause of an alarm - theft, hoax, or error - and to evaluate alternative responses to alarms. Possible responses include conducting investigations, initiating measures to recover stolen SNM, and replying to external threats. Based on the results of each alarm investigation step, the evaluation revises the likelihoods of possible causes of an alarm, and uses this information to determine the optimal sequence of further responses. The choice of an optimal sequence of responses takes into consideration the costs and benefits of successful thefts or hoaxes. These results provide an analytical basis for setting priorities and developing contingency plans for responding to safeguards alarms

  12. Clinical Alarms in intensive care: implications of alarm fatigue for the safety of patients

    Directory of Open Access Journals (Sweden)

    Adriana Carla Bridi

    2014-12-01

    Full Text Available OBJECTIVES: to identify the number of electro-medical pieces of equipment in a coronary care unit, characterize their types, and analyze implications for the safety of patients from the perspective of alarm fatigue.METHOD: this quantitative, observational, descriptive, non-participatory study was conducted in a coronary care unit of a cardiology hospital with 170 beds.RESULTS: a total of 426 alarms were recorded in 40 hours of observation: 227 were triggered by multi-parametric monitors and 199 were triggered by other equipment (infusion pumps, dialysis pumps, mechanical ventilators, and intra-aortic balloons; that is an average of 10.6 alarms per hour.CONCLUSION: the results reinforce the importance of properly configuring physiological variables, the volume and parameters of alarms of multi-parametric monitors within the routine of intensive care units. The alarms of equipment intended to protect patients have increased noise within the unit, the level of distraction and interruptions in the workflow, leading to a false sense of security.

  13. System for alarms analysis and optimization in petrochemicals plants; Sistema para analise e otimizacao de alarmes em plantas petroquimicas

    Energy Technology Data Exchange (ETDEWEB)

    Leitao, Gustavo; Pifer, Aderson; Guedes, Luiz Affonso [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Saito, Kaku; Aquino, Leonardo [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2008-07-01

    The present work presents a group of algorithms, techniques and functionalities on alarms management which can be used efficiently on the treatment of 'disturbances' caused by the informal management of the alarm systems. Among the disturbances handled by these techniques, there is the recognition of intermittent alarms and false alarms, location of alarm floods and correlation between alarms, aiming the identification of communal root causes. The results will be presented through a case study on petrochemical alarm plants. At last, the results obtained by the utilization of such functionalities will be presented and discussed. (author)

  14. Criticality accident alarm system

    International Nuclear Information System (INIS)

    Malenfant, R.E.

    1991-01-01

    The American National Standard ANSI/ANS-8.3-1986, Criticality Accident Alarm System provides guidance for the establishment and maintenance of an alarm system to initiate personnel evacuation in the event of inadvertent criticality. In addition to identifying the physical features of the components of the system, the characteristics of accidents of concern are carefully delineated. Unfortunately, this ANSI Standard has led to considerable confusion in interpretation, and there is evidence that the ''minimum accident of concern'' may not be appropriate. Furthermore, although intended as a guide, the provisions of the standard are being rigorously applied, sometimes with interpretations that are not consistent. Although the standard is clear in the use of absorbed dose in free air of 20 rad, at least one installation has interpreted the requirement to apply to dose in soft tissue. The standard is also clear in specifying the response to both neutrons and gamma rays. An assembly of uranyl fluoride enriched to 5% 235 U was operated to simulate a potential accident. The dose, delivered in a free run excursion 2 m from the surface of the vessel, was greater than 500 rad, without ever exceeding a rate of 20 rad/min, which is the set point for activating an alarm that meets the standard. The presence of an alarm system would not have prevented any of the five major accidents in chemical operations nor is it absolutely certain that the alarms were solely responsible for reducing personnel exposures following the accident. Nevertheless, criticality alarm systems are now the subject of great effort and expense. 13 refs

  15. Ionization smoke detector and alarm system

    International Nuclear Information System (INIS)

    1974-01-01

    An ionization smoke detector particularly suited to residential use is disclosed. The detector is battery-operated and is connected with a non-latching, pulsating alarm circuit. The detector has a sensing chamber formed by a perforated metallic shell and an electrode within which an insulated radiation source is centrally positioned to generate an ionization current for detecting smoke or other similar aerosols. The alarm circuit provides a pulsating alarm signal when smoke levels above a pre-determined value are sensed. The alarm circuit also includes a low voltage detection circuit for sounding the alarm when the end of useful battery life is approaching. (Auth.)

  16. A questionnaire comparison of two alarm systems

    International Nuclear Information System (INIS)

    Collier, Steven G.

    1997-11-01

    A questionnaire was developed, based on guidelines for alarm system design given in NUREG/CR-6105. The intentions were both to develop a subjective instrument for rating the effectiveness of alarm systems and to learn lessons on alarm system design from a comparison of two systems. The questionnaire was administered to reactor operations staff at two locations with different alarm systems embedded in a simulation of the same underlying PWR power plant: Loviisa NPP and Halden Man-Machine Laboratory. The questionnaire, considered as a measuring instrument, had good to high reliability and moderate to good content validity. The questionnaire is considered suitable for further use in the shortened form resulting from this study. Further work is also recommended. The degree of reliability and validity also lend a degree of validation to the NUREG guidelines. The questionnaire was able to show differences between ratings of the two alarm systems. The Loviisa system showed more consistency with other control room features and was better at drawing the operators' attention to important alarms. Both systems were not rated particularly well on alarm prioritisation and spurious alarms. The Halden system was better at showing naturally occurring relationships between alarms. Some of these differences may have been due to the subjects' greater familiarity with the Loviisa alarm system. The results nevertheless show that the questionnaire can measure subjective responses to alarm systems. (author)

  17. Fire auto alarm system intelligent trend

    International Nuclear Information System (INIS)

    Du Chengbao

    1997-01-01

    The author gives the course and trend of the fire alarm system going to more computerized and more intelligent. It is described that only the system applied artificial intelligent and confusion control is the true intelligent fire alarm system. The author gives the detailed analysis on the signal treatment of artificial intelligent applied to analogue fire alarm system as well as the alarm system controlled by confusion technology and artificial nervous net

  18. Hornbills can distinguish between primate alarm calls.

    Science.gov (United States)

    Rainey, Hugo J.; Zuberbühler, Klaus; Slater, Peter J. B.

    2004-01-01

    Some mammals distinguish between and respond appropriately to the alarm calls of other mammal and bird species. However, the ability of birds to distinguish between mammal alarm calls has not been investigated. Diana monkeys (Cercopithecus diana) produce different alarm calls to two predators: crowned eagles (Stephanoaetus coronatus) and leopards (Panthera pardus). Yellow-casqued hornbills (Ceratogymna elata) are vulnerable to predation by crowned eagles but are not preyed on by leopards and might therefore be expected to respond to the Diana monkey eagle alarm call but not to the leopard alarm call. We compared responses of hornbills to playback of eagle shrieks, leopard growls, Diana monkey eagle alarm calls and Diana monkey leopard alarm calls and found that they distinguished appropriately between the two predator vocalizations as well as between the two Diana monkey alarm calls. We discuss possible mechanisms leading to these responses. PMID:15209110

  19. HYBRID ALARM SYSTEMS: COMBINING SPATIAL ALARMS AND ALARM LISTS FOR OPTIMIZED CONTROL ROOM OPERATION

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; J.J. Persensky

    2012-07-01

    The US Department of Energy (DOE) is sponsoring research, development, and deployment on Light Water Reactor Sustainability (LWRS), in which the Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe operational life extension of current nuclear power plants. One of the main areas of focus is control room modernization. Within control room modernization, alarm system upgrades present opportunities to meet the broader goals of the LWRS project in demonstrating the use and safety of the advanced instrumentation and control (I&C) technologies and the short-term and longer term objectives of the plant. In this paper, we review approaches for and human factors issues behind upgrading alarms in the main control room of nuclear power plants.

  20. Clinical Alarms in intensive care: implications of alarm fatigue for the safety of patients1

    Science.gov (United States)

    Bridi, Adriana Carla; Louro, Thiago Quinellato; da Silva, Roberto Carlos Lyra

    2014-01-01

    OBJECTIVES: to identify the number of electro-medical pieces of equipment in a coronary care unit, characterize their types, and analyze implications for the safety of patients from the perspective of alarm fatigue. METHOD: this quantitative, observational, descriptive, non-participatory study was conducted in a coronary care unit of a cardiology hospital with 170 beds. RESULTS: a total of 426 alarms were recorded in 40 hours of observation: 227 were triggered by multi-parametric monitors and 199 were triggered by other equipment (infusion pumps, dialysis pumps, mechanical ventilators, and intra-aortic balloons); that is an average of 10.6 alarms per hour. CONCLUSION: the results reinforce the importance of properly configuring physiological variables, the volume and parameters of alarms of multi-parametric monitors within the routine of intensive care units. The alarms of equipment intended to protect patients have increased noise within the unit, the level of distraction and interruptions in the workflow, leading to a false sense of security. PMID:25591100

  1. Alarms, Chemical

    Science.gov (United States)

    cited in applicable qualitative materiel requirements, small development requirements, technical characteristics, and other requirements and documentation that pertain to automatic chemical agent alarms.

  2. Reducing false asystole alarms in intensive care.

    Science.gov (United States)

    Dekimpe, Remi; Heldt, Thomas

    2017-07-01

    High rates of false monitoring alarms in intensive care can desensitize staff and therefore pose a significant risk to patient safety. Like other critical arrhythmia alarms, asystole alarms require immediate attention by the care providers as a true asystole event can be acutely life threatening. Here, it is illustrated that most false asystole alarms can be attributed to poor signal quality, and we propose and evaluate an algorithm to identify data windows of poor signal quality and thereby help suppress false asystole alarms. The algorithm combines intuitive signal-quality features (degree of signal saturation and baseline wander) and information from other physiological signals that might be available. Algorithm training and testing was performed on the MIMIC II and 2015 PhysioNet/Computing in Cardiology Challenge databases, respectively. The algorithm achieved an alarm specificity of 81.0% and sensitivity of 95.4%, missing only one out of 22 true asystole alarms. On a separate neonatal data set, the algorithm was able to reject 89.7% (890 out of 992) of false asystole alarms while keeping all 22 true events. The results show that the false asystole alarm rate can be significantly reduced through basic signal quality evaluation.

  3. 46 CFR 169.732 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...

  4. 46 CFR 108.627 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED” next to...

  5. Alarm system for ABWR main control panels

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yuji; Saito, Koji [Toshiba Corp., Yokohoma (Japan)

    1997-09-01

    TOSHIBA has developed integrated digital control and instrumentation system for ABWR, which is the third-generation man machine interface system for main control room that we call A-PODIA (Advanced PODIA). A-Podia has been introduced the first actual ABWR plant in Japan. in A-PODIA, TOSHIBA has realized improvement of alarm system that all operator crews in the control room can recognize plant anomalies easily. The alarm system can recognize essential alarms for plant safety easily and understand annunciators with each integrated annunciators and their prioritized color easily by classifying alarms into plant-level essential annunciators, system-level integrated annunciators and equipment level individual annunciators with hierarchical structure. This paper describes conventional alarm system and the design philosophy, alarm system design and operation of ``Alarm System for ABWR Main Control Panels``. (author). 5 refs, 8 figs, 1 tab.

  6. Alarm system for ABWR main control panels

    International Nuclear Information System (INIS)

    Kobayashi, Yuji; Saito, Koji

    1997-01-01

    TOSHIBA has developed integrated digital control and instrumentation system for ABWR, which is the third-generation man machine interface system for main control room that we call A-PODIA (Advanced PODIA). A-Podia has been introduced the first actual ABWR plant in Japan. in A-PODIA, TOSHIBA has realized improvement of alarm system that all operator crews in the control room can recognize plant anomalies easily. The alarm system can recognize essential alarms for plant safety easily and understand annunciators with each integrated annunciators and their prioritized color easily by classifying alarms into plant-level essential annunciators, system-level integrated annunciators and equipment level individual annunciators with hierarchical structure. This paper describes conventional alarm system and the design philosophy, alarm system design and operation of ''Alarm System for ABWR Main Control Panels''. (author). 5 refs, 8 figs, 1 tab

  7. Alarm management a comprehensive guide

    CERN Document Server

    Hollifield, Bill R

    2011-01-01

    In this second edition, Alarm Management: A Comprehensive Guide, various problems of alarm systems are covered with precise guidance on how they come about and how to effectively correct them. It is written by individuals with vast experience in the different plants, processes, and environments requiring effective alarm management. The second edition is filled with good examples and explanations of procedures, with practical lists and tips on how one should proceed. It is based on hundreds of successful projects.

  8. Evaluation of Bus Vibration Comfort Based on Passenger Crowdsourcing Mode

    Directory of Open Access Journals (Sweden)

    Hong Zhao

    2016-01-01

    Full Text Available Vibration comfort is an important factor affecting the quality of service (QoS of bus. In order to make people involved in supervising bus’s vibration comfort and improve passengers’ riding experience, a novel mode of passenger crowdsourcing is introduced. In this paper, comfort degree of bus vibration is calculated from bus’s vibration signals collected by passengers’ smartphones and sent through WiFi to the Boa web server which shows the vibration comfort on the LCD deployed in bus and maybe trigger alarm lamp when the vibration is beyond the threshold. Three challenges here have been overcome: firstly, space coordinate transformation algorithm is used to solve the constant drift of signals collected; secondly, a low-pass filter is designed to isolate gravity from signals real-timely via limited computing resources; thirdly, an embedded evaluation system is developed according to the calculation procedure specified by criterion ISO 2631-1997. Meanwhile, the model proposed is tested in a practical running environment, the vibration data in whole travel are recorded and analyzed offline. The results show that comfort degree of vibration obtained from the experimental system is identical with the truth, and this mode is proved to be effective.

  9. Production of sensitivity and false alarm rate

    International Nuclear Information System (INIS)

    Han Zijie; Kang Wu; Chu Chengsheng; Hao Fanhua; Liu Xiaoya; Cao Lin; Hu Yongbo; Gong Jian; Xiang Yongchun; Zhang Jianhua; Yang Xiangdong

    2007-01-01

    The false alarm rate and sensitivity in nuclear material monitoring system are affected by alarm principle. Two different alarm principles are studied with theory and experiment analysis in this paper. Our research shows that theory analysis and experiment result are accordant very much. This study provides technology support for designing better alarm principle in nuclear material monitoring system. (authors)

  10. Smart container UWB sensor system for situational awareness of intrusion alarms

    Science.gov (United States)

    Romero, Carlos E.; Haugen, Peter C.; Zumstein, James M.; Leach, Jr., Richard R.; Vigars, Mark L.

    2013-06-11

    An in-container monitoring sensor system is based on an UWB radar intrusion detector positioned in a container and having a range gate set to the farthest wall of the container from the detector. Multipath reflections within the container make every point on or in the container appear to be at the range gate, allowing intrusion detection anywhere in the container. The system also includes other sensors to provide false alarm discrimination, and may include other sensors to monitor other parameters, e.g. radiation. The sensor system also includes a control subsystem for controlling system operation. Communications and information extraction capability may also be included. A method of detecting intrusion into a container uses UWB radar, and may also include false alarm discrimination. A secure container has an UWB based monitoring system

  11. 46 CFR 76.15-30 - Alarms.

    Science.gov (United States)

    2010-10-01

    ... than paint and lamp lockers and similar small spaces, shall be fitted with an approved audible alarm in... required to be fitted with a delayed discharge. Such alarms shall be so arranged as to sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and the alarm shall depend...

  12. Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project.

    Science.gov (United States)

    Sowan, Azizeh Khaled; Gomez, Tiffany Michelle; Tarriela, Albert Fajardo; Reed, Charles Calhoun; Paper, Bruce Michael

    2016-01-11

    Clinical alarm systems safety is a national concern, specifically in intensive care units (ICUs) where alarm rates are known to be the highest. Interventional projects that examined the effect of changing default alarm settings on overall alarm rate and on clinicians' attitudes and practices toward clinical alarms and alarm fatigue are scarce. To examine if (1) a change in default alarm settings of the cardiac monitors and (2) in-service nursing education on cardiac monitor use in an ICU would result in reducing alarm rate and in improving nurses' attitudes and practices toward clinical alarms. This quality improvement project took place in a 20-bed transplant/cardiac ICU with a total of 39 nurses. We implemented a unit-wide change of default alarm settings involving 17 parameters of the cardiac monitors. All nurses received an in-service education on monitor use. Alarm data were collected from the audit log of the cardiac monitors 10 weeks before and 10 weeks after the change in monitors' parameters. Nurses' attitudes and practices toward clinical alarms were measured using the Healthcare Technology Foundation National Clinical Alarms Survey, pre- and postintervention. Alarm rate was 87.86 alarms/patient day (a total of 64,500 alarms) at the preintervention period compared to 59.18 alarms/patient day (49,319 alarms) postintervention (P=.01). At baseline, Arterial Blood Pressure (ABP), Pair Premature Ventricular Contractions (PVCs), and Peripheral Capillary Oxygen Saturation (SpO2) alarms were the highest. ABP and SpO2 alarms remained among the top three at the postproject period. Out of the 39 ICU nurses, 24 (62%) provided complete pre- and postproject survey questionnaires. Compared to the preintervention survey, no remarkable changes in the postproject period were reported in nurses' attitudes. Themes in the narrative data were related to poor usability of cardiac monitors and the frequent alarms. The data showed great variation among nurses in terms of changing

  13. Gynecological cancer alarm symptoms:

    DEFF Research Database (Denmark)

    Balasubramaniam, Kirubakaran; Ravn, Pernille; dePont Christensen, René

    2016-01-01

    INTRODUCTION: To determine the proportion of patients who were referred to specialist care after reporting gynecological cancer alarm symptoms to their general practitioner. To investigate whether contact with specialist care was associated with lifestyle factors or socioeconomic status. MATERIAL...... and odds ratios (ORs) for associations between specialist care contact, lifestyle factors and socioeconomic status. RESULTS: The study included 25 866 non-pregnant women; 2957 reported the onset of at least one gynecological cancer alarm symptom, and 683 of these (23.1%) reported symptoms to their general......: Educational level influence contact with specialist care among patients with gynecological cancer alarm symptoms. Future studies should investigate inequalities in access to the secondary healthcare system. This article is protected by copyright. All rights reserved....

  14. Poison and alarm: the Asian hornet Vespa velutina uses sting venom volatiles as an alarm pheromone.

    Science.gov (United States)

    Cheng, Ya-Nan; Wen, Ping; Dong, Shi-Hao; Tan, Ken; Nieh, James C

    2017-02-15

    In colonial organisms, alarm pheromones can provide a key fitness advantage by enhancing colony defence and warning of danger. Learning which species use alarm pheromone and the key compounds involved therefore enhances our understanding of how this important signal has evolved. However, our knowledge of alarm pheromones is more limited in the social wasps and hornets compared with the social bees and ants. Vespa velutina is an economically important and widespread hornet predator that attacks honey bees and humans. This species is native to Asia and has now invaded Europe. Despite growing interest in V. velutina , it was unknown whether it possessed an alarm pheromone. We show that these hornets use sting venom as an alarm pheromone. Sting venom volatiles were strongly attractive to hornet workers and triggered attacks. Two major venom fractions, consisting of monoketones and diketones, also elicited attack. We used gas chromatography coupled to electroantennographic detection (GC-EAD) to isolate 13 known and 3 unknown aliphatic ketones and alcohols in venom that elicited conspicuous hornet antennal activity. Two of the unknown compounds may be an undecen-2-one and an undecene-2,10-dinone. Three major compounds (heptan-2-one, nonan-2-one and undecan-2-one) triggered attacks, but only nonan-2-one did so at biologically relevant levels (10 hornet equivalents). Nonan-2-one thus deserves particular attention. However, the key alarm releasers for V. velutina remain to be identified. Such identification will help to illuminate the evolution and function of alarm compounds in hornets. © 2017. Published by The Company of Biologists Ltd.

  15. TMACS test procedure TP001: Alarm management. Revision 6

    International Nuclear Information System (INIS)

    Scanlan, P.K.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure addresses the Alarm Management requirements of the TMACS. The features to be tested are: real-time alarming on high and low level and discrete alarms, equipment alarms, dead-band filtering, alarm display color coding, alarm acknowledgement, and alarm logging

  16. Systems analysis of a security alarm system

    International Nuclear Information System (INIS)

    Schiff, A.

    1975-01-01

    When the Lawrence Livermore Laboratory found that its security alarm system was causing more false alarms and maintenance costs than LLL felt was tolerable, a systems analysis was undertaken to determine what should be done about the situation. This report contains an analysis of security alarm systems in general and ends with a review of the existing Security Alarm Control Console (SACC) and recommendations for its improvement, growth and change. (U.S.)

  17. Perspectives on use of personal alarms by older fallers

    Directory of Open Access Journals (Sweden)

    Kylie Johnston

    2010-08-01

    Full Text Available Kylie Johnston1, Karen Grimmer-Somers1, Michele Sutherland21International Centre for Allied Health Evidence, University of South Australia, Adelaide; 2Falls Prevention Unit, Department of Health, Government of South Australia, Adelaide, AustraliaBackground: Personal alarms are proposed as a reliable mechanism for older people to obtain assistance after falling. However, little is known about how older people feel about owning and using personal alarms.Aim: This paper reports on experiences of independently living older people, who have recently fallen, regarding alarm use and their independence.Method: Volunteers older than 65 years who had sustained a fall in the previous six months were sought via community invitations. Semistructured telephone interviews were conducted to gain information about their fall and their perspectives on personal alarm use. Interviews were content-analyzed to identify key concepts and themes.Results: Thirty-one interviews were conducted. Twenty callers owned personal alarms. Four subgroups of older fallers were identified; the first group used personal alarms effectively and were advocates for their benefits, the second group owned an alarm but did not use it effectively, the third group did not own alarms mostly because of cost, although were receptive to an alarm should one be provided, and the fourth group did not have an alarm and would not use it even if it was provided.Discussion: Personal alarms produce positive experiences when used effectively by the right people. The cost of personal alarms prohibits some older fallers from being effective alarm users. However, other elderly fallers remain unwilling to consider alarm use even if one was provided. In view of their cost, personal alarms should be targeted to people who will benefit most. ­Alternative strategies should be considered when alarms are unlikely to be used appropriately.Keywords: personal alarm devices, falls, older people, patient perspective

  18. T-Farm complex alarm upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, J.B.

    1995-01-01

    The alarm and controls associated with the T, TX, and TY farms are located in the 242-T control room. The design data for replacement and upgrades of the alarm panels is in this document. This task was canceled previous to the 90% design review point.

  19. Alarm handler for the advanced photon source control system

    International Nuclear Information System (INIS)

    Kraimer, M.R.; Cha, B.K.; Anderson, M.

    1991-01-01

    The Advanced Photon Source (APS), now under construction at Argonne National Laboratory, will have a control system employing graphics workstations at the operator interface level and VME-based microprocessors operating with a distributed database at the field level. The alarm handler is an application utilizing X-Windows running on one or more operator interface workstations which monitors alarms generated by the VME-based microprocessors. Alarms can be grouped in a hierarchical manner. The operator can monitor, acknowledge, and mask alarms either individually or aggregately. Alarm changes of state and all operator modifications are logged. When alarms occur, display windows are automatically generated conveying system and subsystem relationships and severity. Menus are used to modify the alarm action configuration files and to obtain help. Since alarm groups are defined via an alarm configuration file, the alarm handler is a general purpose application which can be customized to monitor a single subsystem or configured to monitor the entire accelerator complex. 2 refs., 2 figs

  20. A new method for defining and managing process alarms and for correcting process operation when an alarm occurs

    International Nuclear Information System (INIS)

    Brooks, Robin; Thorpe, Richard; Wilson, John

    2004-01-01

    A new mathematical treatment of alarms that considers them as multi-variable interactions between process variables has provided the first-ever method to calculate values for alarm limits. This has resulted in substantial reductions in false alarms and hence in alarm annunciation rates in field trials. It has also unified alarm management, process control and product quality control into a single mathematical framework so that operations improvement and hence economic benefits are obtained at the same time as increased process safety. Additionally, an algorithm has been developed that advises what changes should be made to Manipulable process variables to clear an alarm. The multi-variable Best Operating Zone at the heart of the method is derived from existing historical data using equation-free methods. It does not require a first-principles process model or an expensive series of process identification experiments. Integral with the method is a new format Process Operator Display that uses only existing variables to fully describe the multi-variable operating space. This combination of features makes it an affordable and maintainable solution for small plants and single items of equipment as well as for the largest plants. In many cases, it also provides the justification for the investments about to be made or already made in process historian systems. Field Trials have been and are being conducted at IneosChlor and Mallinckrodt Chemicals, both in the UK, of the new geometric process control (GPC) method for improving the quality of both process operations and product by providing Process Alarms and Alerts of much high quality than ever before. The paper describes the methods used, including a simple visual method for Alarm Rationalisation that quickly delivers large sets of Consistent Alarm Limits, and the extension to full Alert Management with highlights from the Field Trials to indicate the overall effectiveness of the method in practice

  1. A new method for defining and managing process alarms and for correcting process operation when an alarm occurs

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, Robin [Curvaceous Software Limited, P.O. Box 43, Gerrards Cross, Bucks SL98UX (United Kingdom)]. E-mail: enquiries@curvaceous.com; Thorpe, Richard [Curvaceous Software Limited, P.O. Box 43, Gerrards Cross, Bucks SL98UX (United Kingdom); Wilson, John [Curvaceous Software Limited, P.O. Box 43, Gerrards Cross, Bucks SL98UX (United Kingdom)

    2004-11-11

    A new mathematical treatment of alarms that considers them as multi-variable interactions between process variables has provided the first-ever method to calculate values for alarm limits. This has resulted in substantial reductions in false alarms and hence in alarm annunciation rates in field trials. It has also unified alarm management, process control and product quality control into a single mathematical framework so that operations improvement and hence economic benefits are obtained at the same time as increased process safety. Additionally, an algorithm has been developed that advises what changes should be made to Manipulable process variables to clear an alarm. The multi-variable Best Operating Zone at the heart of the method is derived from existing historical data using equation-free methods. It does not require a first-principles process model or an expensive series of process identification experiments. Integral with the method is a new format Process Operator Display that uses only existing variables to fully describe the multi-variable operating space. This combination of features makes it an affordable and maintainable solution for small plants and single items of equipment as well as for the largest plants. In many cases, it also provides the justification for the investments about to be made or already made in process historian systems. Field Trials have been and are being conducted at IneosChlor and Mallinckrodt Chemicals, both in the UK, of the new geometric process control (GPC) method for improving the quality of both process operations and product by providing Process Alarms and Alerts of much high quality than ever before. The paper describes the methods used, including a simple visual method for Alarm Rationalisation that quickly delivers large sets of Consistent Alarm Limits, and the extension to full Alert Management with highlights from the Field Trials to indicate the overall effectiveness of the method in practice.

  2. A new method for defining and managing process alarms and for correcting process operation when an alarm occurs.

    Science.gov (United States)

    Brooks, Robin; Thorpe, Richard; Wilson, John

    2004-11-11

    A new mathematical treatment of alarms that considers them as multi-variable interactions between process variables has provided the first-ever method to calculate values for alarm limits. This has resulted in substantial reductions in false alarms and hence in alarm annunciation rates in field trials. It has also unified alarm management, process control and product quality control into a single mathematical framework so that operations improvement and hence economic benefits are obtained at the same time as increased process safety. Additionally, an algorithm has been developed that advises what changes should be made to Manipulable process variables to clear an alarm. The multi-variable Best Operating Zone at the heart of the method is derived from existing historical data using equation-free methods. It does not require a first-principles process model or an expensive series of process identification experiments. Integral with the method is a new format Process Operator Display that uses only existing variables to fully describe the multi-variable operating space. This combination of features makes it an affordable and maintainable solution for small plants and single items of equipment as well as for the largest plants. In many cases, it also provides the justification for the investments about to be made or already made in process historian systems. Field Trials have been and are being conducted at IneosChlor and Mallinckrodt Chemicals, both in the UK, of the new geometric process control (GPC) method for improving the quality of both process operations and product by providing Process Alarms and Alerts of much high quality than ever before. The paper describes the methods used, including a simple visual method for Alarm Rationalisation that quickly delivers large sets of Consistent Alarm Limits, and the extension to full Alert Management with highlights from the Field Trials to indicate the overall effectiveness of the method in practice.

  3. Functional alarming and information retrieval

    International Nuclear Information System (INIS)

    Goodstein, L.P.

    1985-08-01

    This paper deals with two facets of the design and efficient utilisation by operating personnel of computer-based interfaces for monitoring and the supervisory control of complex industrial systems - e.g., power stations, chemical plants, etc. These are alarming and information retrieval both of which are extremely sensitive to computerisation. For example, the advent of computers for display requires that some means of assuring easy and rapid access to large amounts of relevant stored information be found. In this paper, alarming and information retrieval are linked together through a multilevel functional description of the target plant. This representation serves as a framework for structuring the access to information as well as defining associated ''alarms'' at the various descriptive levels. Particular attention is paid to the level where mass and energy flows and balances are relevant. It is shown that the number of alarms here is reduced considerably while information about content and interrelationships is enhanced - which at the same time eases the retrieval problem. (author)

  4. Sensor fusion for intelligent alarm analysis

    International Nuclear Information System (INIS)

    Nelson, C.L.; Fitzgerald, D.S.

    1996-01-01

    The purpose of an intelligent alarm analysis system is to provide complete and manageable information to a central alarm station operator by applying alarm processing and fusion techniques to sensor information. This paper discusses the sensor fusion approach taken to perform intelligent alarm analysis for the Advanced Exterior Sensor (AES). The AES is an intrusion detection and assessment system designed for wide-area coverage, quick deployment, low false/nuisance alarm operation, and immediate visual assessment. It combines three sensor technologies (visible, infrared, and millimeter wave radar) collocated on a compact and portable remote sensor module. The remote sensor module rotates at a rate of 1 revolution per second to detect and track motion and provide assessment in a continuous 360 degree field-of-regard. Sensor fusion techniques are used to correlate and integrate the track data from these three sensors into a single track for operator observation. Additional inputs to the fusion process include environmental data, knowledge of sensor performance under certain weather conditions, sensor priority, and recent operator feedback. A confidence value is assigned to the track as a result of the fusion process. This helps to reduce nuisance alarms and to increase operator confidence in the system while reducing the workload of the operator

  5. Applying AI techniques to improve alarm display effectiveness

    International Nuclear Information System (INIS)

    Gross, J.M.; Birrer, S.A.; Crosberg, D.R.

    1987-01-01

    The Alarm Filtering System (AFS) addresses the problem of information overload in a control room during abnormal operations. Since operators can miss vital information during these periods, systems which emphasize important messages are beneficial. AFS uses the artificial intelligence (AI) technique of object-oriented programming to filter and dynamically prioritize alarm messages. When an alarm's status changes, AFS determines the relative importance of that change according to the current process state. AFS bases that relative importance on relationships the newly changed alarm has with other activated alarms. Evaluations of a alarm importance take place without regard to the activation sequence of alarm signals. The United States Department of Energy has applied for a patent on the approach used in this software. The approach was originally developed by EG and G Idaho for a nuclear reactor control room

  6. The LEP alarm system

    International Nuclear Information System (INIS)

    Tyrrell, M.W.

    1992-01-01

    Unlike alarm systems for previous accelerators, the LEP alarm system caters not only for the operation of the accelerator but also for technical services and provides the direct channel for personnel safety. It was commissioned during 1989 and has seen a continued development up to the present day. The system, comprising over 50 computers including 5 different platforms and 4 different operating systems, is described. The hierarchical structure of the software is outlined from the interface to the equipment groups, through the front end computers to the central server, and finally to the operator consoles. Reasons are given for choosing a conventional, as opposed to a 'knowledge based' approach. Finally, references are made to a prototype real time expert system for surveying the power converters of LEP, which was conducted during 1990 as part of the alarm development program. (author)

  7. 46 CFR 97.37-9 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...

  8. 46 CFR 78.47-9 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping... and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” (b) [Reserved] ...

  9. 46 CFR 196.37-9 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...

  10. Los Alamos Scientific Laboratory long-range alarm system

    International Nuclear Information System (INIS)

    DesJardin, R.; Machanik, J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) Long-Range Alarm System is described. The last few years have brought significant changes in the Department of Energy regulations for protection of classified documents and special nuclear material. These changes in regulations have forced a complete redesign of the LASL security alarm system. LASL covers many square miles of varying terrain and consists of separate technical areas connected by public roads and communications. A design study over a period of 2 years produced functional specifications for a distributed intelligence, expandable alarm system that will handle 30,000 alarm points from hundreds of data concentrators spread over a 250-km 2 area. Emphasis in the design was on nonstop operation, data security, data communication, and upward expandability to incorporate fire alarms and the computer-aided dispatching of security and fire vehicles. All aspects of the alarm system were to be fault tolerant from the central computer system down to but not including the individual data concentrators. Redundant communications lines travel over public domain from the alarmed area to the central alarm station

  11. Interspecific semantic alarm call recognition in the solitary Sahamalaza sportive lemur, Lepilemur sahamalazensis.

    Directory of Open Access Journals (Sweden)

    Melanie Seiler

    Full Text Available As alarm calls indicate the presence of predators, the correct interpretation of alarm calls, including those of other species, is essential for predator avoidance. Conversely, communication calls of other species might indicate the perceived absence of a predator and hence allow a reduction in vigilance. This "eavesdropping" was demonstrated in birds and mammals, including lemur species. Interspecific communication between taxonomic groups has so far been reported in some reptiles and mammals, including three primate species. So far, neither semantic nor interspecific communication has been tested in a solitary and nocturnal lemur species. The aim of this study was to investigate if the nocturnal and solitary Sahamalaza sportive lemur, Lepilemur sahamalazensis, is able to access semantic information of sympatric species. During the day, this species faces the risk of falling prey to aerial and terrestrial predators and therefore shows high levels of vigilance. We presented alarm calls of the crested coua, the Madagascar magpie-robin and aerial, terrestrial and agitation alarm calls of the blue-eyed black lemur to 19 individual Sahamalaza sportive lemurs resting in tree holes. Songs of both bird species' and contact calls of the blue-eyed black lemur were used as a control. After alarm calls of crested coua, Madagascar magpie-robin and aerial alarm of the blue-eyed black lemur, the lemurs scanned up and their vigilance increased significantly. After presentation of terrestrial alarm and agitation calls of the blue-eyed black lemur, the animals did not show significant changes in scanning direction or in the duration of vigilance. Sportive lemur vigilance decreased after playbacks of songs of the bird species and contact calls of blue-eyed black lemurs. Our results indicate that the Sahamalaza sportive lemur is capable of using information on predator presence as well as predator type of different sympatric species, using their referential

  12. Advanced alarm systems: Display and processing issues

    Energy Technology Data Exchange (ETDEWEB)

    O`Hara, J.M. [Brookhaven National Lab., Upton, NY (United States); Wachtel, J.; Perensky, J. [US Nuclear Regulatory Commission, Washington, DC (United States). Office of Nuclear Regulatory Research

    1995-05-01

    This paper describes a research program sponsored by the US Nuclear Regulatory Commission to address the human factors engineering (HFE) deficiencies associated with nuclear power plant alarm systems. The overall objective of the study is to develop HFE review guidance for alarm systems. In support of this objective, human performance issues needing additional research were identified. Among the important issues were alarm processing strategies and alarm display techniques. This paper will discuss these issues and briefly describe our current research plan to address them.

  13. Speech Alarms Pilot Study

    Science.gov (United States)

    Sandor, Aniko; Moses, Haifa

    2016-01-01

    Speech alarms have been used extensively in aviation and included in International Building Codes (IBC) and National Fire Protection Association's (NFPA) Life Safety Code. However, they have not been implemented on space vehicles. Previous studies conducted at NASA JSC showed that speech alarms lead to faster identification and higher accuracy. This research evaluated updated speech and tone alerts in a laboratory environment and in the Human Exploration Research Analog (HERA) in a realistic setup.

  14. 21 CFR 870.1100 - Blood pressure alarm.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  15. Alarm processing system using AI techniques for nuclear power plant

    International Nuclear Information System (INIS)

    Yang, Joon On; Chang, Soon Heung

    1990-01-01

    An alarm processing system (APS) has been developed using artificial intelligence (AI) techniques. The alarms of nuclear power plants (NPP's) are classified into the generalized and special alarms. The generalized alarms are also classified into the global and local alarms. For each type of alarms, the specific processing rules are applied to filter and suppress unnecessary and potentially misleading alarms. The local processing are based on 'model-based reasoning.' The global and special alarms are processed by using the general cause-consequence check rules. The priorities of alarms are determined according to the plant state and the consistencies between them

  16. Auditory backup alarms: distance-at-first-detection via in-situ experimentation on alarm design and hearing protection effects.

    Science.gov (United States)

    Alali, Khaled; Casali, John G

    2012-01-01

    The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them

  17. Game Theoretic Approach for Systematic Feature Selection; Application in False Alarm Detection in Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Fatemeh Afghah

    2018-03-01

    Full Text Available Intensive Care Units (ICUs are equipped with many sophisticated sensors and monitoring devices to provide the highest quality of care for critically ill patients. However, these devices might generate false alarms that reduce standard of care and result in desensitization of caregivers to alarms. Therefore, reducing the number of false alarms is of great importance. Many approaches such as signal processing and machine learning, and designing more accurate sensors have been developed for this purpose. However, the significant intrinsic correlation among the extracted features from different sensors has been mostly overlooked. A majority of current data mining techniques fail to capture such correlation among the collected signals from different sensors that limits their alarm recognition capabilities. Here, we propose a novel information-theoretic predictive modeling technique based on the idea of coalition game theory to enhance the accuracy of false alarm detection in ICUs by accounting for the synergistic power of signal attributes in the feature selection stage. This approach brings together techniques from information theory and game theory to account for inter-features mutual information in determining the most correlated predictors with respect to false alarm by calculating Banzhaf power of each feature. The numerical results show that the proposed method can enhance classification accuracy and improve the area under the ROC (receiver operating characteristic curve compared to other feature selection techniques, when integrated in classifiers such as Bayes-Net that consider inter-features dependencies.

  18. Useful and usable alarm systems : recommended properties

    International Nuclear Information System (INIS)

    Veland, Oeystein; Kaarstad, Magnhild; Seim, Lars Aage; Foerdestroemmen, Nils T.

    2001-01-01

    This document describes the result of a study on alarm systems conducted by IFE in Halden. The study was initiated by the Norwegian Petroleum Directorate. The objective was to identify and formulate a set of important properties for useful and usable alarm systems. The study is mainly based on review of the latest international recognised guidelines and standards on alarm systems available at the time of writing, with focus on realistic solutions from research and best practice from different industries. In addition, IFE experiences gathered through specification and design of alarm systems and experimental activities in HAMMLAB and bilateral projects, have been utilized where relevant. The document presents a total of 43 recommendations divided into a number of general recommendations and more detailed recommendations on alarm generation, structuring, prioritisation, presentation and handling. (Author)

  19. General methods for alarm reduction; Larmsanering med generella metoder

    Energy Technology Data Exchange (ETDEWEB)

    Ahnlund, Jonas; Bergquist, Tord; Raaberg, Martin [Lund Univ. (Sweden). Dept. of Information Technology

    2003-10-01

    The information in the control rooms has increased due to the technological advances in process control. Large industries produce large data quantities, where some information is unnecessary or even incorrect. The operator needs support from an advanced and well-adjusted alarm system to be able to separate a real event from a minor disturbance. The alarms must be of assistance and not a nuisance. An enhanced alarm situation qualifies an increased efficiency with fewer production disturbances and an improved safety. Yet, it is still unusual that actions are taken to improve the situation. An alarm cleanup with general methods can shortly be described as taking advantage of the control systems built-in functions, the possibility to modify or create function blocks and fine-tune the settings in the alarm system. In this project, we make use of an intelligent software, Alarm Cleanup Toolbox, that simulate different signal processing methods and tries to find improved settings on all the signals in the process. This is a fast and cost-efficient way to improve the overall alarm situation, and lays a foundation for more advanced alarm systems. An alarm cleanup has been carried out at Flintraennan district heating plant in Malmoe, where various signal processing methods has been implemented in a parallel alarm system. This made it possible to compare the two systems under the same conditions. The result is very promising, and shows that a lot of improvements can be achieved with very little effort. An analysis of the alarm system at Vattenreningen (the water purification process) at Heleneholmsverket in Malmoe has been carried out. Alarm Cleanup Toolbox has, besides suggesting improved settings, also found logical errors in the alarm system. Here, no implementation was carried out and therefore the results are analytical, but they validate the efficiency of the general methods. The project has shown that an alarm cleanup with general methods is cost-efficient, and that the

  20. A false-alarm aware methodology to develop robust and efficient multi-scale infrared small target detection algorithm

    Science.gov (United States)

    Moradi, Saed; Moallem, Payman; Sabahi, Mohamad Farzan

    2018-03-01

    False alarm rate and detection rate are still two contradictory metrics for infrared small target detection in an infrared search and track system (IRST), despite the development of new detection algorithms. In certain circumstances, not detecting true targets is more tolerable than detecting false items as true targets. Hence, considering background clutter and detector noise as the sources of the false alarm in an IRST system, in this paper, a false alarm aware methodology is presented to reduce false alarm rate while the detection rate remains undegraded. To this end, advantages and disadvantages of each detection algorithm are investigated and the sources of the false alarms are determined. Two target detection algorithms having independent false alarm sources are chosen in a way that the disadvantages of the one algorithm can be compensated by the advantages of the other one. In this work, multi-scale average absolute gray difference (AAGD) and Laplacian of point spread function (LoPSF) are utilized as the cornerstones of the desired algorithm of the proposed methodology. After presenting a conceptual model for the desired algorithm, it is implemented through the most straightforward mechanism. The desired algorithm effectively suppresses background clutter and eliminates detector noise. Also, since the input images are processed through just four different scales, the desired algorithm has good capability for real-time implementation. Simulation results in term of signal to clutter ratio and background suppression factor on real and simulated images prove the effectiveness and the performance of the proposed methodology. Since the desired algorithm was developed based on independent false alarm sources, our proposed methodology is expandable to any pair of detection algorithms which have different false alarm sources.

  1. Object-oriented alarm-filtering system

    International Nuclear Information System (INIS)

    Corsberg, D.R.; Wilkie, D.

    1986-01-01

    This paper discusses an alarm-filtering system (AFS) being developed by EG and G Idaho, Inc. for the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory. The ultimate goal of this project is to place AFS into ATR's reactor control room to act as an aid during major plant transients. In addition, methods of alarm analysis are investigated based on functional relationships rather than on a historical approach utilizing cause-consequence trees. Artificial intelligence techniques, including object-oriented programming, are also demonstrated as useful in analyzing alarms and alarm sequences. After a brief description of the problem AFS addresses, this paper discusses the design constraints and human factors that influenced the development of the system. The reader is then presented with operational and architectural descriptions of the system as well as what directions the future development of AFS may take. The fact that AFS is being considered as a partial solution to the problems discussed in the next section demonstrates the viability of its underlying technology and approach. 10 refs

  2. An experimental evaluation of alarm processing and display characteristics

    International Nuclear Information System (INIS)

    O'Hara, J.; Brown, W.; Hallbert, B.; Skraaning, G.Jr.; Persensky, J.; Wachtel, J.

    1998-01-01

    This paper describes a research program sponsored by the U.S. Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. As part of this program, guidance has been developed based on a broad base of technical and research literature. In the course of guidance development, aspects of alarm system design for which the technical basis was insufficient to support complete guidance development were identified. The primary purpose of the research reported in this paper was to evaluate the effects of three of these alarm system design characteristics on operator performance in order to contribute to the understanding of potential safety issues and to provide data to support the development of design review guidance in these areas. Three alarm system design characteristics studied were (1) alarm processing (degree of alarm reduction), (2) alarm availability (dynamic prioritization and suppression), and (3) alarm display (a dedicated tile format, a mixed tile and message list format, and a format in which alarm information is integrated into the process displays). A secondary purpose was to provide confirmatory evidence of selected alarm system guidance developed in an earlier phase of the project. The alarm characteristics were combined into eight separate experimental conditions. Six, two-person crews of professional nuclear power plant operators participated in the study. Following training, each crew completed 16 test trials which consisted of two trials in each of the eight experimental conditions (one with a low-complexity scenario and one with a high-complexity scenario). Measures of process performance. operator task performance, situation awareness, and workload were obtained. In addition. operator opinions and evaluations of the alarm processing and display conditions were collected. Numerous strengths

  3. Line supervision of alarm communications

    International Nuclear Information System (INIS)

    Chritton, M.R.

    1991-01-01

    The objective of this paper is to explain the role and application of alarm communication link supervision in security systems such as for nuclear facilities. The vulnerabilities of the various types of alarm communication links will be presented. Throughout the paper, an effort has been made to describe only those technologies commercially available and to avoid speculative theoretical solutions

  4. Alarm management for process control a best-practice guide for design, implementation, and use of industrial alarm systems

    CERN Document Server

    Rothenberg, Douglas H

    2014-01-01

    No modern industrial enterprise, particularly in such areas as chemical processing, can operate without a secure, and reliable, network of automated monitors and controls. And those operations need alarm systems to alert engineers and managers the moment anything goes wrong or needs attention. This book, by one of the world's leading experts on industrial alarm systems, will provide A to Z coverage of designing, implementing, and maintaining an effective alarm network.

  5. Development of the newly advanced alarm system for APWR plant

    International Nuclear Information System (INIS)

    Shimada, Manabu; Yamamoto, Yoshihiro; Tani, Mamoru; Kobashi, Shuichi

    1997-01-01

    We have been developing AMCB (Advanced Main Control Board) for APWR consisting of a large overview display and on operator console. We have adopted the alarm prioritizing functions, which are already in use in the existing Japanese PWR plants, for easier identification of the high priority alarms. Moreover, we have developed an alarm system with a large overview display, which presents alarms on the plant process flow diagram. This enhances the location aids and pattern recognition in the alarm identification process. This time, we made further improvement and studies for better and various functions combining a large overview display with a CRT display. We determined the alarm system specification as follows, taking account of flexible alarm recognition processes. (1) The high priority alarms can be identified upon the LOD (large overview display). On the display, the alarms are described on the plant flow diagram, and the alarm status is shown on the fixed position of process or equipment symbols. (2) Other alarms are identified on large overview display and on CRTs using a hierarchical process. (3) The alarm messages are divided into 4 different groups according to the plant systems, thus enabling to undertake the countermeasure operations, using only the CRT. Moreover, we integrated a computerized ARPs (Alarm Response Procedures) into the alarm system. (author). 4 figs, 5 tabs

  6. Development of the newly advanced alarm system for APWR plant

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Manabu; Yamamoto, Yoshihiro; Tani, Mamoru; Kobashi, Shuichi [Kansai Electric Power Co., Inc., Osaka (Japan)

    1997-09-01

    We have been developing AMCB (Advanced Main Control Board) for APWR consisting of a large overview display and on operator console. We have adopted the alarm prioritizing functions, which are already in use in the existing Japanese PWR plants, for easier identification of the high priority alarms. Moreover, we have developed an alarm system with a large overview display, which presents alarms on the plant process flow diagram. This enhances the location aids and pattern recognition in the alarm identification process. This time, we made further improvement and studies for better and various functions combining a large overview display with a CRT display. We determined the alarm system specification as follows, taking account of flexible alarm recognition processes. (1) The high priority alarms can be identified upon the LOD (large overview display). On the display, the alarms are described on the plant flow diagram, and the alarm status is shown on the fixed position of process or equipment symbols. (2) Other alarms are identified on large overview display and on CRTs using a hierarchical process. (3) The alarm messages are divided into 4 different groups according to the plant systems, thus enabling to undertake the countermeasure operations, using only the CRT. Moreover, we integrated a computerized ARPs (Alarm Response Procedures) into the alarm system. (author). 4 figs, 5 tabs.

  7. Model Predictive Vibration Control Efficient Constrained MPC Vibration Control for Lightly Damped Mechanical Structures

    CERN Document Server

    Takács, Gergely

    2012-01-01

    Real-time model predictive controller (MPC) implementation in active vibration control (AVC) is often rendered difficult by fast sampling speeds and extensive actuator-deformation asymmetry. If the control of lightly damped mechanical structures is assumed, the region of attraction containing the set of allowable initial conditions requires a large prediction horizon, making the already computationally demanding on-line process even more complex. Model Predictive Vibration Control provides insight into the predictive control of lightly damped vibrating structures by exploring computationally efficient algorithms which are capable of low frequency vibration control with guaranteed stability and constraint feasibility. In addition to a theoretical primer on active vibration damping and model predictive control, Model Predictive Vibration Control provides a guide through the necessary steps in understanding the founding ideas of predictive control applied in AVC such as: ·         the implementation of ...

  8. Alarm management in gas pipeline plant: a case study

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Juliano; Lima, Marcelo; Leitao, Gustavo; Guedes, Luiz Affonso [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Branco, Nicolau; Coelho, Robson; Elias, Gustavo Passos; Nunes, Marcelo [Transportadora Brasileira Gasoduto Bolivia-Brasil (TBG), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    In order to improve the requirements of industrial processes, many decision support systems have been introduced in recent years. In this context, the alarm management systems have great relevance. On the other hand, the informatics revolution allowed a great increase of information concerning the operation of the industrial processes. Currently, process operators handle an excessive number of about 1.500 alarms per day. Thus, this overdose of information implies in the discredit of alarms. Then, in order to improve the operation activities of industrial processes, it is mandatory to incorporate procedures to evaluate and rationalize alarms. Since the EMMUA191 Standard is the reference guide to alarm management, but it does not specify how to execute an alarm management procedure, in this paper, a systematic procedure to evaluate alarms configurations in industrial processes is proposed. This procedure is in line with EMMUA191 and is composed by the following steps: to use statistics analyses to identify problematic alarms, such as occurrence, intermittency, correlation, and flooding calculation; to indicate problematic alarm group; and to propose a set of actions to be implemented. To validate our proposal, we present a case study in a gas pipeline plant using the BR-AlarmExpert software. (author)

  9. Alarm criteria in radiation portal monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Burr, Tom [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States)]. E-mail: tburr@lanl.gov; Gattiker, James R. [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States); Myers, Kary [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States); Tompkins, George [Los Alamos National Laboratory, Risk Analysis and Decision Support Systems, Stop F609, Los Alamos, NM 87545 (United States)

    2007-05-15

    Gamma detectors at border crossings are intended to detect illicit nuclear material. These detectors collect counts that are used to determine whether to trigger an alarm. Several candidate alarm rules are evaluated, with attention to background suppression caused by the vehicle. Because the count criterion leads to many nuisance alarms and because background suppression by the vehicle is smaller for ratios of counts, analysis of a ratio criterion is included. Detection probability results that consider the effects of 5 factors are given for 2 signal-injection studies, 1 for counts, and 1 for count ratios.

  10. Alarm criteria in radiation portal monitoring

    International Nuclear Information System (INIS)

    Burr, Tom; Gattiker, James R.; Myers, Kary; Tompkins, George

    2007-01-01

    Gamma detectors at border crossings are intended to detect illicit nuclear material. These detectors collect counts that are used to determine whether to trigger an alarm. Several candidate alarm rules are evaluated, with attention to background suppression caused by the vehicle. Because the count criterion leads to many nuisance alarms and because background suppression by the vehicle is smaller for ratios of counts, analysis of a ratio criterion is included. Detection probability results that consider the effects of 5 factors are given for 2 signal-injection studies, 1 for counts, and 1 for count ratios

  11. Alleviation of Buffet-Induced Vibration Using Piezoelectric Actuators

    National Research Council Canada - National Science Library

    Morgenstern, Shawn D

    2006-01-01

    .... The objective of this research was to determine the most critical natural modes of vibration for the F-16 ventral fin and design piezoelectric actuators capable of reducing buffet-induced ventral fin vibration...

  12. Development of a criticality alarm system neutron detector: Final project report

    International Nuclear Information System (INIS)

    O'Dell, A.A.

    1989-05-01

    The primary objective of this project was to develop a prototype neutron detector for use in criticality alarm systems (CASs) at US Department of Energy (DOE) and contractor facilities wherever significant amounts of fissile material are processed or stored. Constraints placed on the design of the detector were that the overall size of the detector was to be as small as practical, the input voltage requirements were to be no more than 24 V, and that the gamma sensitivity would be as low as possible. Also, the detector should give dosimetric neutron response, and should have sufficient temporal capabilities to measure the entire range from fast (>1 ms) to slow (seconds to minutes) excursions, and sufficient dynamic range to measure from background to over 100 times background levels to insure proper activation of the Immediate Evacuation Alarm (IEA). Finally, the detector should insure rapid (<1 s) activation of the IEA in the event of a criticality excursion. 24 figs., 11 tabs

  13. A Study on Performance Requirements for Advanced Alarm System

    International Nuclear Information System (INIS)

    Seong, Duk Hyun; Jeong, Jae Hoon; Sim, Young Rok; Ko, Jong Hyun; Kim, Jung Seon; Jang, Gwi Sook; Park, Geun Ok

    2005-01-01

    A design goals of advanced alarm system is providing advanced alarm information to operator in main control room. To achive this, we applied computer based system to Alarm System. Because, It should apply data management and advanced alarm processing(ie. Data Base Mangegment System and S/W module for alarm processing). These are not impossible in analog based alarm system. And, preexitance research examples are made on digital computer. We have digital systems for test of advanced alarm system table and have tested and studied using by test equipment in the view point of the system performance, stability and security. In this paper, we discribed about general software architecture of preexitance research examples. Also, CPU performance and requirements of system software that served to accommodate it, stability and security

  14. Framework for analyzing safeguards alarms and response decisions

    International Nuclear Information System (INIS)

    Al-Ayat, R.A.; Judd, B.R.; McCord, R.K.

    1982-01-01

    This paper describes a quantitative approach to help evaluate and respond to safeguards alarms. These alrms may be generated internally by a facility's safeguards systems or externally by individuals claiming to possess stolen Special Nuclear Material (SNM). This approach can be used to identify the most likely cause of an alarm - theft, hoax, or error - and to evaluate alternative responses to alarms. Possible responses include conducting investigations, initiating measures to recover stolen SNM, and replying to external threats. Based on the results of each alarm investigation step, the evaluation revises the likelihoods of possible causes of an alarm, and uses this information to determine the optimal sequence of further responses. The choice of an optimal sequence of responses takes into consideration the costs and benefits of successful thefts or hoaxes. These results provide an analytical basis for setting priorities and developing contingency plans for responding to safeguards alarms

  15. NIF Ambient Vibration Measurements

    International Nuclear Information System (INIS)

    Noble, C.R.; Hoehler, M.S.; S.C. Sommer

    1999-01-01

    LLNL has an ongoing research and development project that includes developing data acquisition systems with remote wireless communication for monitoring the vibrations of large civil engineering structures. In order to establish the capability of performing remote sensing over an extended period of time, the researchers needed to apply this technology to a real structure. The construction of the National Ignition Facility provided an opportunity to test the data acquisition system on a large structure to monitor whether the facility is remaining within the strict ambient vibration guidelines. This document will briefly discuss the NIF ambient vibration requirements and summarize the vibration measurements performed during the Spring and Summer of 1999. In addition, a brief description of the sensors and the data acquisition systems will be provided in Appendix B

  16. Alarm points for fixed oxygen monitors

    International Nuclear Information System (INIS)

    Miller, G.C.

    1987-05-01

    Oxygen concentration monitors were installed in a vault where numerous pipes carried inert cryogens and gases to the Mirror Fusion Test Facility (MFTF-B) experimental vessel at Lawrence Livermore National Laboratory (LLNL). The problems associated with oxygen-monitoring systems and the reasons why such monitors were installed were reviewed. As a result of this review, the MFTF-B monitors were set to sound an evacuation alarm when the oxygen concentration fell below 18%. We chose the 18% alarm criterion to minimize false alarms and to allow time for personnel to escape in an oxygen-deficient environment

  17. Classification of alarm processing techniques and human performance issues

    International Nuclear Information System (INIS)

    Kim, I.S.; O'Hara, J.M.

    1993-01-01

    Human factors reviews indicate that conventional alarm systems based on the one sensor, one alarm approach, have many human engineering deficiencies, a paramount example being too many alarms during major disturbances. As an effort to resolve these deficiencies, various alarm processing systems have been developed using different techniques. To ensure their contribution to operational safety, the impacts of those systems on operating crew performance should be carefully evaluated. This paper briefly reviews some of the human factors research issues associated with alarm processing techniques and then discusses a framework with which to classify the techniques. The dimensions of this framework can be used to explore the effects of alarm processing systems on human performance

  18. Classification of alarm processing techniques and human performance issues

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I.S.; O' Hara, J.M.

    1993-01-01

    Human factors reviews indicate that conventional alarm systems based on the one sensor, one alarm approach, have many human engineering deficiencies, a paramount example being too many alarms during major disturbances. As an effort to resolve these deficiencies, various alarm processing systems have been developed using different techniques. To ensure their contribution to operational safety, the impacts of those systems on operating crew performance should be carefully evaluated. This paper briefly reviews some of the human factors research issues associated with alarm processing techniques and then discusses a framework with which to classify the techniques. The dimensions of this framework can be used to explore the effects of alarm processing systems on human performance.

  19. Classification of alarm processing techniques and human performance issues

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I.S.; O`Hara, J.M.

    1993-05-01

    Human factors reviews indicate that conventional alarm systems based on the one sensor, one alarm approach, have many human engineering deficiencies, a paramount example being too many alarms during major disturbances. As an effort to resolve these deficiencies, various alarm processing systems have been developed using different techniques. To ensure their contribution to operational safety, the impacts of those systems on operating crew performance should be carefully evaluated. This paper briefly reviews some of the human factors research issues associated with alarm processing techniques and then discusses a framework with which to classify the techniques. The dimensions of this framework can be used to explore the effects of alarm processing systems on human performance.

  20. Alarm handling systems and techniques developed to match operator tasks

    International Nuclear Information System (INIS)

    Bye, A.; Moum, B.R.

    1997-01-01

    This paper covers alarm handling methods and techniques explored at the Halden Project, and describes current status on the research activities on alarm systems. Alarm systems are often designed by application of a bottom-up strategy, generating alarms at component level. If no structuring of the alarms is applied, this may result in alarm avalanches in major plant disturbances, causing cognitive overload of the operator. An alarm structuring module should be designed using a top-down approach, analysing operator's tasks, plant states, events and disturbances. One of the operator's main tasks during plant disturbances is status identification, including determination of plant status and detection of plant anomalies. The main support of this is provided through the alarm systems, the process formats, the trends and possible diagnosis systems. The alarm system should both physically and conceptually be integrated with all these systems. 9 refs, 5 figs

  1. Alarm handling systems and techniques developed to match operator tasks

    Energy Technology Data Exchange (ETDEWEB)

    Bye, A; Moum, B R [Institutt for Energiteknikk, Halden (Norway). OECD Halden Reaktor Projekt

    1997-09-01

    This paper covers alarm handling methods and techniques explored at the Halden Project, and describes current status on the research activities on alarm systems. Alarm systems are often designed by application of a bottom-up strategy, generating alarms at component level. If no structuring of the alarms is applied, this may result in alarm avalanches in major plant disturbances, causing cognitive overload of the operator. An alarm structuring module should be designed using a top-down approach, analysing operator`s tasks, plant states, events and disturbances. One of the operator`s main tasks during plant disturbances is status identification, including determination of plant status and detection of plant anomalies. The main support of this is provided through the alarm systems, the process formats, the trends and possible diagnosis systems. The alarm system should both physically and conceptually be integrated with all these systems. 9 refs, 5 figs.

  2. An Evidence-Based Approach to Reducing Cardiac Telemetry Alarm Fatigue.

    Science.gov (United States)

    Srinivasa, Ekta; Mankoo, Jaspreet; Kerr, Charles

    2017-08-01

    It is estimated that between 80% and 99% of alarms in the clinical areas are in actionable alarms (Gross, Dahl, & Nielson). Alarm management is one of the Joint Commission's National Patient Safety Goals (2014) because sentinel events have directly been linked to the devices generating these alarms. At an acute care facility in Boston, a multidisciplinary team consisting of Nursing, Biomedical Engineers, Patient Safety and Providers was formed to conduct a pilot study on the state of telemetry alarms on a surgical floor. An evidence-based approach was taken utilizing Philips Real-time data exporter alarms tracking software to capture all telemetry alarms during a 43-day time span. Likewise, noise meters were placed near telemetry alarm speakers to track decibel levels within the aforementioned timeframe for 21 days. Analysis of the data showed that clinically insignificant Premature Ventricular Contractions (PVC) alarms accounted for more than 40% of all alarms in the unit within the time span, while also contributing to an average noise level of 58.49 dB. In response to the data, the interdisciplinary team approved to permanently default the settings for PAIR PVC, MULTIFORM PVC, and RUN PVC alarms to off. The results showed a 54% decrease in the rate of alarms per bed per day, and an average noise reduction of 2.3 dB between the two selected noise measurement areas. Organizing a multidisciplinary team provides an effective framework toward analyzing and addressing cardiac telemetry alarm fatigue. Looking at quantitative datasets for clinical care areas through various lenses helps identify opportunities for improvement in regards to highlighting alarms that are not actionable. Pilot changes to alarm parameters can be tested for their environmental impact in the care area. © 2017 Sigma Theta Tau International.

  3. Retrofitting alarm prioritization at Bruce A: strategy development and implementation experience

    International Nuclear Information System (INIS)

    Davey, E.; Hickey, D.; Babcock, B.

    1997-01-01

    A prioritization strategy for computer-displayed control room alarms has been developed for Bruce A to better assist operations staff in visually identifying key alarms and judging the relative importance of alarms. The strategy consists of assigning each alarm indicative of a problem to be addressed to one of five priority categories. Each alarm is assigned to an alarm category based on an off-line analysis of the consequence and response characteristics applicable to the alarm for three plant operating contexts. The colour of the alarm message is used to convey the priority category of each alarm in computer-based alarm displays. In addition, alarms indicative of non-problematic changes in the state of plant equipment and processes are given a separate colour assignment to visually differentiate them from alarms indicative of problems. This paper outlines the user-based approach employed in the prioritization strategy development, describes the key features of the prioritization strategy adopted, and discusses the initial experience in systematically determining the priority assignments for all 6000 computer-based alarms associated with each generating unit. (author)

  4. Computational Human Performance Modeling For Alarm System Design

    Energy Technology Data Exchange (ETDEWEB)

    Jacques Hugo

    2012-07-01

    The introduction of new technologies like adaptive automation systems and advanced alarms processing and presentation techniques in nuclear power plants is already having an impact on the safety and effectiveness of plant operations and also the role of the control room operator. This impact is expected to escalate dramatically as more and more nuclear power utilities embark on upgrade projects in order to extend the lifetime of their plants. One of the most visible impacts in control rooms will be the need to replace aging alarm systems. Because most of these alarm systems use obsolete technologies, the methods, techniques and tools that were used to design the previous generation of alarm system designs are no longer effective and need to be updated. The same applies to the need to analyze and redefine operators’ alarm handling tasks. In the past, methods for analyzing human tasks and workload have relied on crude, paper-based methods that often lacked traceability. New approaches are needed to allow analysts to model and represent the new concepts of alarm operation and human-system interaction. State-of-the-art task simulation tools are now available that offer a cost-effective and efficient method for examining the effect of operator performance in different conditions and operational scenarios. A discrete event simulation system was used by human factors researchers at the Idaho National Laboratory to develop a generic alarm handling model to examine the effect of operator performance with simulated modern alarm system. It allowed analysts to evaluate alarm generation patterns as well as critical task times and human workload predicted by the system.

  5. Semi-supervised detection of intracranial pressure alarms using waveform dynamics

    International Nuclear Information System (INIS)

    Scalzo, Fabien; Hu, Xiao

    2013-01-01

    Patient monitoring systems in intensive care units (ICU) are usually set to trigger alarms when abnormal values are detected. Alarms are generated by threshold-crossing rules that lead to high false alarm rates. This is a recognized issue that causes alarm fatigue, waste of human resources, and increased patient risks. Recently developed smart alarm models require alarms to be validated by experts during the training phase. The manual annotation process involved is time-consuming and virtually impossible to achieve for the thousands of alarms recorded in the ICU every week. To tackle this problem, we investigate in this study if the use of semi-supervised learning methods, that can naturally integrate unlabeled data samples in the model, can be used to improve the accuracy of the alarm detection. As a proof of concept, the detection system is evaluated on intracranial pressure (ICP) signal alarms. Specific morphological and trending features are extracted from the ICP signal waveform to capture the dynamic of the signal prior to alarms. This study is based on a comprehensive dataset of 4791 manually labeled alarms recorded from 108 neurosurgical patients. A comparative analysis is provided between kernel spectral regression (SR-KDA) and support vector machine (SVM) both modified for the semi-supervised setting. Results obtained during the experimental evaluations indicate that the two models can significantly reduce false alarms using unlabeled samples; especially in the presence of a restrained number of labeled examples. At a true alarm recognition rate of 99%, the false alarm reduction rates improved from 9% (supervised) to 27% (semi-supervised) for SR-KDA, and from 3% (supervised) to 16% (semi-supervised) for SVM. (paper)

  6. Ground test for vibration control demonstrator

    Science.gov (United States)

    Meyer, C.; Prodigue, J.; Broux, G.; Cantinaud, O.; Poussot-Vassal, C.

    2016-09-01

    In the objective of maximizing comfort in Falcon jets, Dassault Aviation is developing an innovative vibration control technology. Vibrations of the structure are measured at several locations and sent to a dedicated high performance vibration control computer. Control laws are implemented in this computer to analyse the vibrations in real time, and then elaborate orders sent to the existing control surfaces to counteract vibrations. After detailing the technology principles, this paper focuses on the vibration control ground demonstration that was performed by Dassault Aviation in May 2015 on Falcon 7X business jet. The goal of this test was to attenuate vibrations resulting from fixed forced excitation delivered by shakers. The ground test demonstrated the capability to implement an efficient closed-loop vibration control with a significant vibration level reduction and validated the vibration control law design methodology. This successful ground test was a prerequisite before the flight test demonstration that is now being prepared. This study has been partly supported by the JTI CleanSky SFWA-ITD.

  7. JOYO operation support system 'JOYCAT' based on intelligent alarm handling

    International Nuclear Information System (INIS)

    Tamaoki, Tetsuo; Yamamoto, Hiroki; Sato, Masuo; Yoshida, Megumu; Kaneko, Tomoko; Terunuma, Seiichi; Takatsuto, Hiroshi; Morimoto, Makoto.

    1992-01-01

    An operation support system for the experimental fast reactor 'JOYO' was developed based on an intelligent alarm-handling. A specific feature of this system, called JOYCAT (JOYO Consulting and Analyzing Tool), is in its sequential processing structure that a uniform treatment by using design knowledge base is firstly applied for all activated alarms, and an exceptional treatment by using heuristic knowledge base is then applied only for the former results. This enables us to achieve real-time and flexible alarm-handling. The first alarm-handling determines the candidates of causal alarms, important alarms with which the operator should firstly cope, through identifying the cause-consequence relations among alarms based on the design knowledge base in which importance and activating conditions are described for each of 640 alarms in a frame format. The second alarm-handling makes the final judgement with the candidates by using the heuristic knowledge base described as production rules. Then, operation manuals concerning the most important alarms are displayed to operators. JOYCAT has been in commission since September of 1990, after a wide scope of validation tests by using an on-site full-scope training simulator. (author)

  8. A Design of Alarm System in a Research Reactor Facility

    International Nuclear Information System (INIS)

    Park, Jaekwan; Jang, Gwisook; Seo, Sangmun; Suh, Yongsuk

    2013-01-01

    The digital alarm system has become an indispensable design to process a large amount of alarms of power plants. Korean research reactor operated for decades maintains a hybrid alarm system with both an analog annunciator and a digital alarm display. In this design, several alarms are indicated on an analog panel and digital display, respectively, and it requires more attention and effort of the operators. As proven in power plants, a centralized alarm system design is necessary for a new research reactor. However, the number of alarms and operators in a research reactor is significantly lesser than power plants. Thus, simplification should be considered as an important factor for the operation efficiency. This paper introduces a simplified alarm system. As advances in information technology, fully digitalized alarm systems have been applied to power plants. In a new research reactor, it will be more useful than an analog or hybrid configuration installed in research reactors decades ago. However, the simplification feature should be considered as an important factor because the number of alarms and number of operators in a research reactor is significantly lesser than in power plants

  9. Improved Laser Vibration Radar

    National Research Council Canada - National Science Library

    Hilaire, Pierre

    1998-01-01

    .... This thesis reconfigured an existing CO2 laboratory laser radar system that is capable of measuring the frequencies of vibration of a simulated target into a more compact and rugged form for field testing...

  10. Nuclear-power-plant perimeter-intrusion alarm systems

    International Nuclear Information System (INIS)

    Halsey, D.J.

    1982-04-01

    Timely intercept of an intruder requires the examination of perimeter barriers and sensors in terms of reliable detection, immediate assessment and prompt response provisions. Perimeter security equipment and operations must at the same time meet the requirements of the Code of Federal Regulations, 10 CFR 73.55 with some attention to the performance and testing figures of Nuclear Regulatory Guide 5.44, Revision 2, May 1980. A baseline system is defined which recommends a general approach to implementing perimeter security elements: barriers, lighting, intrusion detection, alarm assessment. The baseline approach emphasizes cost/effectiveness achieved by detector layering and logic processing of alarm signals to produce reliable alarms and low nuisance alarm rates. A cost benefit of layering along with video assessment is reduction in operating expense. The concept of layering is also shown to minimize testing costs where detectability performance as suggested by Regulatory Guide 5.44 is to be performed. Synthesis of the perimeter intrusion alarm system and limited testing of CCTV and Video Motion Detectors (VMD), were performed at E-Systems, Greenville Division, Greenville, Texas during 1981

  11. Novel active vibration absorber with magnetorheological fluid

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, T; Ehrlich, J; Boese, H [Fraunhofer-Institut fuer Silicatforschung ISC, Neunerplatz 2, D-97082 Wuerzburg (Germany)], E-mail: thomas.gerlach@isc.fraunhofer.de

    2009-02-01

    Disturbing vibrations diminish the performance of technical high precision devices significantly. In search of a suitable solution for reducing these vibrations, a novel concept of active vibration reduction was developed which exploits the special properties of magnetorheological fluids. In order to evaluate the concept of such an active vibration absorber (AVA) a demonstrator was designed and manufactured. This demonstrator generates a force which counteracts the motion of the vibrating body. Since the counterforce is generated by a centrifugal exciter, the AVA provides the capability to compensate vibrations even in two dimensions. To control the strength of the force transmitted to the vibrating body, the exciter is based on a tunable MR coupling. The AVA was integrated in an appropriate testing device to investigate its performance. The recorded results show a significant reduction of the vibration amplitudes by an order of magnitude.

  12. Review of design criteria for Criticality Accident Alarm System (CAAS) used in Fuel Reprocessing Facility

    International Nuclear Information System (INIS)

    Chandrasekaran, S.; Basu, Pew; Sivasubramaniyan, K.; Venkatraman, B.

    2016-01-01

    Though fuel cycle facilities handling fissile materials are designed with careful criticality safety analysis, the criticality accident cannot be ruled out completely. Criticality Accident Alarm System (CAAS) is being installed as part of criticality safety management in fuel cycle facilities. CAAS system being used in India, is ECIL make, ionization chamber based gamma detector, which houses three identical detectors and works on 2/3 logic. As per ISO 7753 and ANSI/ANS-8.3, the CAAS must be designed to be capable of detecting any minimum accident occurs which could be of concern. Based on this, alarm limit used in CAAS is: 4 R/h (fast transient excursion) and 3 mR in 0.5 sec (slow excursion). In case of reprocessing facilities wherein process tanks located in heavy shielding, identification of CAAS installation locations require detailed radiation transport calculations. A study has been taken to estimate the gamma dose rate from thick concrete hot cells in order to determine the locations of CAAS to meet the present design criteria of alarm limit

  13. 46 CFR 78.47-75 - Ventilation alarm failure.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72... FAILURE IN VEHICULAR SPACE.” (b) [Reserved] [CGFR 66-33, 31 FR 15284, Dec. 6, 1966] ...

  14. The false alarm at Forsmark March 6th 1986

    International Nuclear Information System (INIS)

    Hultaaker, Oe.

    1986-01-01

    118 households were interviewed by telephone. Additional interviews were made with the representatives of the nuclear plant, county alarming center, Radio Uppland and the authorities in question. Six out of ten households heard the false alarm. Less than one out of twenty believed that it was an alarm caused by real danger and seven out of ten think that there will be more false alarms. (G.B.)

  15. Alarm criteria for the fixed gamma radiation monitoring stations

    International Nuclear Information System (INIS)

    Kjelle, P.E.

    1987-01-01

    For the type of measurement considered here, an alarm based on the dose excess has been shown to be a more certain method of indicating that a true alarm situation exists than an alarm based on the dose-rate exceeding a given dose-rate level. The method offers a number of advantages: Dose-rate levels can be recorded over long periods without any necessity of making manual changes in the alarm level due to seasonal variations in the background level. A relatively low level can be specified without an unnecessary number of false alarms being triggered by gamma-emitting radon daughters. (orig./HP)

  16. Analysis of vibroprotection characteristics of pneumatic relaxation seat suspension with capability of vibration energy recuperation

    Directory of Open Access Journals (Sweden)

    Lyashenko Mikhail

    2017-01-01

    Full Text Available This paper proposes mechanism and control algorithm for pneumatic relaxation system of suspension with vibration energy recuperation applied to standard vehicle operator seat (“Sibeko” company. Mathematical model of the seat pneumatic relaxation suspension with two additional air volumes was created. Pneumatic motor – recuperator activated by means of air flow from the one additional volume to another is installed in air piping between additional volumes. Computational research was made in Matlab/Simulink. Amplitude-frequency characteristics of transmission coefficient for standard and proposed suspensions were plotted for preliminary evaluation of vibration protection properties of seat suspension. Performed comparative analysis of amplitude-frequency characteristics shows that noticeable improvement of vibration protection properties of pneumatic relaxation suspension system with vibration energy recuperation in comparison with standard system both in region of resonance disturbances and in above-resonance region. Main ways for further improvement of vibration protection properties of proposed system were marked out.

  17. Urethral alarm probe for permanent prostate implants

    International Nuclear Information System (INIS)

    Cutajar, D.; Lerch, M.; Takacs, G.

    2008-01-01

    We have developed a urethral dosimetry system for real time dose verification along the urethra during permanent implant prostate brachytherapy. The urethral alarm uses 'spectroscopic dosimetry' to calculate the dose rate along the urethra in real time. The application of spectroscopic dosimetry for the urethral alarm probe was verified using Monte Carlo calculations. In phantom depth dose measurements as well as isotropy measurements were performed to verify the usefulness of the urethra alarm probe as an in vivo real time dosimeter. (author)

  18. Understanding of bridge cable vibrations and the associate flow-field through the full-scale monitoring of vibrations and Wind

    DEFF Research Database (Denmark)

    Acampora, Antonio

    This dissertation investigates the conditions that promote rain-wind-induced vibrations of inclined cable on cable-stayed bridges. Rain-wind-induced vibrations are known as the most common type of cable vibrations and capable of severe vibrations. The recent increase in the number of cable stayed...... bridges continuously becoming longer and lighter have resulted in a high number of observations of cable vibrations. A theoretical background for the tool used in this work is presented in terms of cables vibrations mechanisms, aerodynamic damping and system identification techniques. A detailed...... literature review of reported observations of rain-wind-induced cable vibrations of fullscale bridges is shown. The database of observed events on bridges collects information about the conditions that likely develop the phenomenon, together with the means used to suppress or reduce the occurrence of cable...

  19. Method and device for monitoring vibration of incore neutron detector guide tube

    International Nuclear Information System (INIS)

    Enomoto, Mitsuhiro; Naito, Norio; Oda, Akira.

    1978-01-01

    Purpose: To easily detect the vibration of an incore neutron detector guide tube and to prevent the occurrence of such accidents that the guide tube comes into contact with the fuel channel box arranged around the periphery thereof to break the channel box. Method: A neutron detector guide tube is disposed within a channel box, and the neutron detector is arranged at the center of the guide tube. Now, when the guide tube vibrates at an inherent number of vibration and a predetermined amplitude, the guide tube moves in the radial direction by the predetermined amplitude part to come into contact with the channel box. Upon this occasion, the detector similarity vibrates, and the output signal is varied by the predetermined neutron flux variation part. This output signal is sent to a comparator through an analyser, and compared with the output signal produced from a device wherein the result analysed at normal time, and the output signal is sent to an alarm device and an indicator, respectively. (Aizawa, K.)

  20. Resolution of alarms for loss of bulk nuclear material

    International Nuclear Information System (INIS)

    Eggers, R.F.; Davenport, L.C.

    1982-01-01

    Under methods of material accountability considered in the NRC's Reform Amendment (Federal Register, 46(175):45144 to 45151 dated September 10, 1981) prompt detection of losses and resolution of alarms play a central role in the day-to-day activities of the Material Control and Accounting (MC and A) System. This paper will discuss the two basic pathways of alarm resolution, namely, verification of the magnitude of the loss indicated by the initial alarm, and detection of deliberate or accidental accounting discrepancies. Progress along these pathways leads to a consensus that either (1) a loss occurred, (2) the original alarm was caused by MC and A error, or (3) the cause of the original alarm is uncertain. Three phases of response will be outlined and an example of response to alarms will be given for a mixed oxide powder processing control unit

  1. Adjustable electronic load-alarm relay

    International Nuclear Information System (INIS)

    Mason, C.H.; Sitton, R.S.

    1976-01-01

    An improved electronic alarm relay for monitoring the current drawn by an ac motor or other electrical load is described. The circuit is designed to measure the load with high accuracy and to have excellent alarm repeatability. Chattering and arcing of the relay contacts are minimal. The operator can adjust the set point easily and can re-set both the high and the low alarm points by means of one simple adjustment. The relay includes means for generating a signal voltage proportional to the motor current. In a preferred form of the invention a first operational amplifier is provided to generate a first constant reference voltage which is higher than a preselected value of the signal voltage. A second operational amplifier is provided to generate a second constant reference voltage which is lower than the aforementioned preselected value of the signal voltage. A circuit comprising a first resistor serially connected to a second resistor is connected across the outputs of the first and second amplifiers, and the junction of the two resistors is connected to the inverting terminal of the second amplifier. Means are provided to compare the aforementioned signal voltage with both the first and second reference voltages and to actuate an alarm if the signal voltage is higher than the first reference voltage or lower than the second reference voltage

  2. Experimental evaluation of human-system interaction on alarm design

    International Nuclear Information System (INIS)

    Huang, F.-H.; Lee, Y.-L.; Hwang, S.-L.; Yenn, T.-C.; Yu, Y.-C.; Hsu, C.-C.; Huang, H.-W.

    2007-01-01

    This study evaluates the practicability of automatic reset alarm system in Fourth Nuclear Power Plant (FNPP) of Taiwan. The features of auto-reset alarm system include dynamic prioritization of all alarm signals and fast system reset. Two experiments were conducted to evaluate the effect of automatic/manual reset on operation time, situational awareness (SA), task load index (TLX), and subjective ratings. All participants, including Experts and Novices, took part in the experiment on the alarm system simulator with Load Rejection procedure. The experimental results imply that the auto-reset alarm system may be applied in an advanced control room under Load Rejection procedure, because all participants' operation time were reduced as well as Novice's SA were raised up. Nevertheless, to ensure operating safety in FNPP, the effects of the auto-reset alarm system in other procedures/special situations still need to be tested in the near future

  3. The impact of recent changes in smoke alarm legislation on residential fire injuries and smoke alarm ownership in New South Wales, Australia.

    Science.gov (United States)

    Harvey, Lara A; Poulos, Roslyn G; Sherker, Shauna

    2013-01-01

    In 2006, New South Wales (NSW) state legislation changed from requiring smoke alarms in new houses only to all houses. We evaluated the impact of this legislative change on residential fire injury and smoke alarm ownership characteristics. Residential fire injuries for 2002 to 2010 were identified from hospitalization data for all hospitals in NSW. Data relating to smoke alarm ownership and demographic factors were obtained from the NSW Population Health Survey. Negative binomial regression analysis was used to analyze trends over time. Prior to the introduction of universal legislation, hospitalization rates were increasing slightly; however, following the introduction of legislation, hospitalization rates decreased by an estimated 36.2% (95% confidence interval [CI], 16.7-55.8) annually. Smoke alarm ownership increased from 73.3% (95% CI, 72.5-74.2) prelegislation to 93.6% (95% CI, 93.1-94.2) 18 months postlegislation. Thirty percent of households reported testing their alarms regularly. Speaking a language other than English (relative risks [RRs], 1.82; 95% CI, 1.44-2.99), allowing smoking in the home (RR, 1.73; 95% CI, 1.31-2.27), and being part of the most disadvantaged socioeconomic group (RR, 1.47; 95% CI, 1.14-1.91) remain major risk factors for nonownership. Broadening the scope of state legislation has had a positive impact on residential fire-related hospitalizations and smoke alarm ownership. However, it is of concern that the legislation has been the least effective in increasing smoke alarm ownership among non-English-speaking households, in households where smoking is allowed, in low socioeconomic households, and that a high proportion of householders do not test their smoke alarms regularly. Targeted campaigns are needed to reach these high-risk groups and to ensure that smoke alarms are functional.

  4. Practical design of a nonlinear tuned vibration absorber

    DEFF Research Database (Denmark)

    Grappasonni, C.; Habib, G.; Detroux, T.

    2014-01-01

    The aim of the paper is to develop a new nonlinear tuned vibration absorber (NLTVA) capable of mitigating the vibrations of nonlinear systems which are known to exhibit frequency-energy-dependent oscillations. A nonlinear generalization of Den Hartog's equal-peak method is proposed to ensure equa...

  5. Do aphid colonies amplify their emission of alarm pheromone?

    Science.gov (United States)

    Hatano, Eduardo; Kunert, Grit; Bartram, Stefan; Boland, Wilhelm; Gershenzon, Jonathan; Weisser, Wolfgang W

    2008-09-01

    When aphids are attacked by natural enemies, they emit alarm pheromone to alert conspecifics. For most aphids tested, (E)-beta-farnesene (EBF) is the main, or only, constituent of the alarm pheromone. In response to alarm pheromone, alerted aphids drop off the plant, walk away, or attempt to elude predators. However, under natural conditions, EBF concentration might be low due to the low amounts emitted, to rapid air movement, or to oxidative degradation. To ensure that conspecifics are warned, aphids might conceivably amplify the alarm signal by emitting EBF in response to EBF emitted by other aphids. To examine whether such amplification occurs, we synthesized deuterated EBF (DEBF), which allowed us to differentiate between applied and aphid-derived chemical. Colonies of Acyrthosiphon pisum were treated with DEBF, and headspace volatiles were collected and analyzed for evidence of aphid-derived EBF. No aphid-derived EBF was detected, suggesting that amplification of the alarm signal does not occur. We discuss the disadvantages of alarm signal reinforcement.

  6. Patient characteristics associated with false arrhythmia alarms in intensive care

    Directory of Open Access Journals (Sweden)

    Harris PR

    2017-04-01

    Full Text Available Patricia R Harris,1,2 Jessica K Zègre-Hemsey,3,4 Daniel Schindler,5 Yong Bai,6 Michele M Pelter,2,7 Xiao Hu2,8 1Department of Nursing, School of Health and Natural Sciences, Dominican University of California, San Rafael, 2Department of Physiological Nursing, School of Nursing, University of California, San Francisco, CA, 3School of Nursing, 4Department of Emergency Medicine, School of Medicine, University of North Carolina at Chapel Hill, NC, 5Intensive Care Unit, The Neuroscience Center, Sutter Eden Medical Center, Castro Valley, 6Hu Research Laboratory, Department of Physiological Nursing, School of Nursing, University of California, San Francisco, 7ECG Monitoring Research Lab, Department of Physiological Nursing, School of Nursing, 8Physiological Nursing and Neurological Surgery, Affiliate Faculty of Institute for Computational Health Sciences Core Faculty UCB/UCSF Joint Bio-Engineering Graduate Program, University of California, San Francisco, CA, USA Introduction: A high rate of false arrhythmia alarms in the intensive care unit (ICU leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. Objective: The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. Methods: This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and

  7. AI-based alarm processing for a nuclear power plant

    International Nuclear Information System (INIS)

    Na, N.J.; Kim, I.S.; Hwang, I.K.; Lee, D.Y.; Ham, C.S.

    1996-01-01

    A real-time expert system is implemented using artificial intelligence and object-oriented technology for alarm processing and presentation in a nuclear power plant. The knowledge base is constructed based on some schemes to process and display alarms to the plant operators. The activated alarms are dynamically prioritized by the reasoning rules, and then, presented on the process mimic overview and by some other means. To demonstrate the proposed system, the alarm processing and presentation is carried out in a simulated environment of the TMI-2 accident

  8. Wallac automatic alarm dosimeter type RAD21

    International Nuclear Information System (INIS)

    Burgess, P. H.; Iles, W.J.

    1980-02-01

    The Automatic Alarm Dosimeter type RAD 21 is a batterypowered personal dosemeter and exposure rate alarm monitor, designed to be worn on the body, covering an exposure range from 0.1 to 999.9 mR and has an audible alarm which can be pre-set over the range 1 mR h -1 to 250 mR h -1 . The instrument is designed to measure x- and γ radiation over the energy range 50 keV to 3 MeV. The facilities and controls, the radiation, electrical, environmental and mechanical characteristics, and the manual, have been evaluated. (U.K.)

  9. FAULT DIAGNOSIS WITH MULTI-STATE ALARMS IN A NUCLEAR POWER CONTROL SIMULATOR

    Energy Technology Data Exchange (ETDEWEB)

    Austin Ragsdale; Roger Lew; Brian P. Dyre; Ronald L. Boring

    2012-10-01

    This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effect of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. We used sensitivity and criterion based on Signal Detection Theory to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed better and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.

  10. Assessment method to predict the rate of unresolved false alarms

    International Nuclear Information System (INIS)

    Reardon, P.T.; Eggers, R.F.; Heaberlin, S.W.

    1982-06-01

    A method has been developed to predict the rate of unresolved false alarms of material loss in a nuclear facility. The computer program DETRES-1 was developed. The program first assigns the true values of control unit components receipts, shipments, beginning and ending inventories. A normal random number generator is used to generate measured values of each component. A loss estimator is calculated from the control unit's measured values. If the loss estimator triggers a detection alarm, a response is simulated. The response simulation is divided into two phases. The first phase is to simulate remeasurement of the components of the detection loss estimator using the same or better measurement methods or inferences from surrounding control units. If this phase of response continues to indicate a material loss, phase of response simulating a production shutdown and comprehensive cleanout is initiated. A new loss estimator is found, and tested against the alarm thresholds. If the estimator value is below the threshold, the original detection alarm is considered resolved; if above the threshold, an unresolved alarm has occurred. A tally is kept of valid alarms, unresolved false alarms, and failure to alarm upon a true loss

  11. Transactions of the criticality alarm systems workshop

    International Nuclear Information System (INIS)

    1988-01-01

    The first Criticality Alarm workshop was held by the US Department of Energy Albuquerque Operations Office in 1985. This second workshop is the first held on an international level. There were 98 persons in attendance. They represented the Department of Energy (DOE) field offices, DOE contractors, the Nuclear Regulatory Commission (NRC), NRC licensees, and agencies in the United Kingdom, France, West Germany, and Japan. Topics were on practices experience, and development. A key value of the workshop was the sharing of critical alarm system experiences, problems, and advances in the state of the art. In addition, several Criticality Alarm Systems (CAS) equipment systems were exhibited. Papers were presented on: nature of criticality accidents; lessons learned from past accidents; application of ANS 8.3 standard; gamma and neutron detection systems; research and development in progress; testing at Oak Ridge and Los Alamos; methods used to place detectors; centralized readout feature; false alarms; trip-point settings; and testing and maintenance. The individual papers have been cataloged separately

  12. Alarm systems a guide to design, management and procurement

    CERN Document Server

    Engineering Equipment and Materials Users' Association. London

    2013-01-01

    Alarm systems form an essential part of the operator interfaces to large modern industrial facilities. They provide vital support to the operators by warning them of situations that need their attention and have an important role in preventing, controlling and mitigating the effects of abnormal situations. Since it was first published in 1999, EEMUA 191 has become the globally accepted and leading guide to good practice for all aspects of alarm systems. The guide, developed by users of alarm systems with input from the GB Health and Safety Executive, gives comprehensive guidance on designing, managing and procuring an effective alarm system. The new Third Edition has been comprehensively updated and includes guidance on implementing the alarm management philosophy in practice; applications in geographically distributed processes; and performance metrics and KPIs.

  13. Sensor fusion for active vibration isolation in precision equipment

    NARCIS (Netherlands)

    Tjepkema, D.; van Dijk, Johannes; Soemers, Herman

    2012-01-01

    Sensor fusion is a promising control strategy to improve the performance of active vibration isolation systems that are used in precision equipment. Normally, those vibration isolation systems are only capable of realizing a low transmissibility. Additional objectives are to increase the damping

  14. Alarm Fatigue vs User Expectations Regarding Context-Aware Alarm Handling in Hospital Environments Using CallMeSmart.

    Science.gov (United States)

    Solvoll, Terje; Arntsen, Harald; Hartvigsen, Gunnar

    2017-01-01

    Surveys and research show that mobile communication systems in hospital settings are old and cause frequent interruptions. In the quest to remedy this, an Android based communication system called CallMeSmart tries to encapsulate most of the frequent communication into one hand held device focusing on reducing interruptions and at the same time make the workday easier for healthcare workers. The objective of CallMeSmart is to use context-awareness techniques to automatically monitor the availability of physicians' and nurses', and use this information to prevent or route phone calls, text messages, pages and alarms that would otherwise compromise patient care. In this paper, we present the results from interviewing nurses on alarm fatigue and their expectations regarding context-aware alarm handling using CallMeSmart.

  15. Dynamic alarm response procedures

    International Nuclear Information System (INIS)

    Martin, J.; Gordon, P.; Fitch, K.

    2006-01-01

    The Dynamic Alarm Response Procedure (DARP) system provides a robust, Web-based alternative to existing hard-copy alarm response procedures. This paperless system improves performance by eliminating time wasted looking up paper procedures by number, looking up plant process values and equipment and component status at graphical display or panels, and maintenance of the procedures. Because it is a Web-based system, it is platform independent. DARP's can be served from any Web server that supports CGI scripting, such as Apache R , IIS R , TclHTTPD, and others. DARP pages can be viewed in any Web browser that supports Javascript and Scalable Vector Graphics (SVG), such as Netscape R , Microsoft Internet Explorer R , Mozilla Firefox R , Opera R , and others. (authors)

  16. Complex programmable logic device based alarm sequencer for nuclear power plants

    International Nuclear Information System (INIS)

    Khedkar, Ravindra; Solomon, J. Selva; KrishnaKumar, B.

    2001-01-01

    Complex Programmable Logic Device based Alarm Sequencer is an instrument, which detects alarms, memorizes them and displays the sequences of occurrence of alarms. It caters to sixteen alarm signals and distinguishes the sequence among any two alarms with a time resolution of 1 ms. The system described has been designed for continuous operation in process plants, nuclear power plants etc. The system has been tested and found to be working satisfactorily. (author)

  17. Design of alarm systems in Swedish nuclear power plants

    International Nuclear Information System (INIS)

    Thunberg, Anna; Osvalder, Anna-Lisa

    2008-04-01

    Research within the area of improving alarm system design and performance has mainly focused on new alarm systems. However, smaller modernisations of legacy systems are more common in the Swedish nuclear industry than design of totally new systems. This imposes problems when the new system should function together with the old system. This project deals with the special concerns raised by modernisation projects. The objective of the project has been to increase the understanding of the relationship between the operator's performance and the design of the alarm system. Of major concern has been to consider the cognitive abilities of the operator, different operator roles and work situations, and varying need of information. The aim of the project has been to complement existing alarm design guidance and to develop user-centred alarm design concepts. Different case studies have been performed in several industry sectors (nuclear, oil refining, pulp and paper, aviation and medical care) to identify best practice. Several empirical studies have been performed within the nuclear area to investigate the operator's need of information, performance and workload in different operating modes. The aspect of teamwork has also been considered. The analyses show that the operator has different roles in different work situations which affect both the type of information needed and how the information is processed. In full power operation, the interaction between the operator and the alarm system is driven by internal factors and the operator tries to maintain high situation awareness by actively searching for information. The operator wants to optimise the process and need detailed information with possibilities to follow-up and get historical data. In disturbance management, the operator is more dependent on external information presented by the alarm system. The new compilation of alarm guidance is based on the operator's varying needs in different working situations and is

  18. Contribution of computerization to alarm processing: A French safety view

    Energy Technology Data Exchange (ETDEWEB)

    Cette, W [CEA Centre d` Etudes de Fontenay-aux-Roses, 92 (France). Inst. de Protection et de Surete Nucleaire

    1997-09-01

    Following the TMI accident and according to the requirement of the French safety authority, very important studies were performed by the French utility, Electricite de France (EDF), and assessed by the Institute for Nuclear Safety and Protection (IPSN) on reactor operation in conventional control rooms, particularly on alarm processing. These studies dealt with the man-machine interface, as well as design and exploitation requirements, presentation and management of alarm signals, and associated operating documents. The conclusions of these studies have led to improvements in French conventional control rooms. The current state of these control rooms and links between alarm sets and operating documents will be shortly presented in the first part of the paper. More recently, the computerized means implemented in the PWR 1400 MWe control rooms (N4) profoundly modified reactor operation. In particular, major advances concern alarm processing in comparison with conventional control rooms. The N4 plants provide a more rigorous approach in processing and presentation of alarms than in the past. Indeed, EDF wanted to have less alarms switched on during plant upsets and to make them more characteristic of a specific situation of the process. For example, computerization makes it easier to validate or inhibit alarms according to the situation, to allow the operator to manage alarm presentation and to propose on-line alarm sheets to the operator etc. This approach in comparison with conventional control rooms, and the IPSN assessment will be presented in the second part of this paper. (author).

  19. Contribution of computerization to alarm processing: A French safety view

    International Nuclear Information System (INIS)

    Cette, W.

    1997-01-01

    Following the TMI accident and according to the requirement of the French safety authority, very important studies were performed by the French utility, Electricite de France (EDF), and assessed by the Institute for Nuclear Safety and Protection (IPSN) on reactor operation in conventional control rooms, particularly on alarm processing. These studies dealt with the man-machine interface, as well as design and exploitation requirements, presentation and management of alarm signals, and associated operating documents. The conclusions of these studies have led to improvements in French conventional control rooms. The current state of these control rooms and links between alarm sets and operating documents will be shortly presented in the first part of the paper. More recently, the computerized means implemented in the PWR 1400 MWe control rooms (N4) profoundly modified reactor operation. In particular, major advances concern alarm processing in comparison with conventional control rooms. The N4 plants provide a more rigorous approach in processing and presentation of alarms than in the past. Indeed, EDF wanted to have less alarms switched on during plant upsets and to make them more characteristic of a specific situation of the process. For example, computerization makes it easier to validate or inhibit alarms according to the situation, to allow the operator to manage alarm presentation and to propose on-line alarm sheets to the operator etc. This approach in comparison with conventional control rooms, and the IPSN assessment will be presented in the second part of this paper. (author)

  20. Behavioral alarm treatment for nocturnal enuresis

    Directory of Open Access Journals (Sweden)

    Rodrigo F. Pereira

    2010-06-01

    Full Text Available PURPOSES: To investigate the efficacy of alarm treatment in a sample of Brazilian children and adolescents with nocturnal enuresis and relate treatment success to age and type of clinical support. MATERIALS AND METHODS: During 32 weeks, 84 children and adolescents received alarm treatment together with weekly psychological support sessions for individual families or groups of 5 to 10 families. RESULTS: 71% of the participants achieved success, defined as 14 consecutive dry nights. The result was similar for children and adolescents and for individual or group support. The time until success was shorter for participants missing fewer support sessions. CONCLUSIONS: Alarm treatment was effective for the present sample, regardless of age or type of support. Missing a higher number of support sessions, which may reflect low motivation for treatment, increased the risk of failure.

  1. Spiny lobsters detect conspecific blood-borne alarm cues exclusively through olfactory sensilla.

    Science.gov (United States)

    Shabani, Shkelzen; Kamio, Michiya; Derby, Charles D

    2008-08-01

    When attacked by predators, diverse animals actively or passively release molecules that evoke alarm and related anti-predatory behavior by nearby conspecifics. The actively released molecules are alarm pheromones, whereas the passively released molecules are alarm cues. For example, many insects have alarm-signaling systems that involve active release of alarm pheromones from specialized glands and detection of these signals using specific sensors. Many crustaceans passively release alarm cues, but the nature of the cues, sensors and responses is poorly characterized. Here we show in laboratory and field experiments that injured Caribbean spiny lobsters, Panulirus argus, passively release alarm cues via blood (hemolymph) that induce alarm responses in the form of avoidance and suppression of feeding. These cues are detected exclusively through specific olfactory chemosensors, the aesthetasc sensilla. The alarm cues for Caribbean spiny lobsters are not unique to the species but do show some phylogenetic specificity: P. argus responds primarily with alarm behavior to conspecific blood, but with mixed alarm and appetitive behaviors to blood from the congener Panulirus interruptus, or with appetitive behaviors to blood from the blue crab Callinectes sapidus. This study lays the foundation for future neuroethological studies of alarm cue systems in this and other decapod crustaceans.

  2. Implementation of the Integrated Alarm System for KOMAC facility using EPICS framework and Eclipse

    International Nuclear Information System (INIS)

    Song, Young-Gi; Kim, Jae-Ha; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub

    2017-01-01

    The alarm detecting layer is the component that monitors alarm signals which are transported to the processing part through message queue. The main purpose of the processing part is to transfer the alarm signals connecting an alarm identification and state of the alarm to database system. The operation interface of system level signal links has been developed by EPICS framework. EPICS tools have been used for monitoring device alarm status. The KOMAC alarm system was developed for offering a user-friendly, intuitive user interface. The alarm system is implemented with EPICS IOC for alarm server, eclipse-mars integrated development tool for alarm viewer, and mariadb for alarm log. The new alarm system supports intuitive user interface on alarm information and alarm history. Alarm view has plans to add login function, user permission on alarm acknowledge, user permission of PV import, search and report function.

  3. Stop the Noise: A Quality Improvement Project to Decrease Electrocardiographic Nuisance Alarms.

    Science.gov (United States)

    Sendelbach, Sue; Wahl, Sharon; Anthony, Anita; Shotts, Pam

    2015-08-01

    As many as 99% of alarm signals may not need any intervention and can result in patients' deaths. Alarm management is now a Joint Commission National Patient Safety Goal. To reduce the number of nuisance electrocardiographic alarm signals in adult patients on the medical cardiovascular care unit. A quality improvement process was used that included eliminating duplicative alarms, customizing alarms, changing electrocardiography electrodes daily, standardizing skin preparation, and using disposable electrocardiography leads. In the cardiovascular care unit, the mean number of electrocardiographic alarm signals per day decreased from 28.5 (baseline) to 3.29, an 88.5% reduction. Use of a bundled approach to managing alarm signals decreased the mean number of alarm signals in a cardiovascular care unit. ©2015 American Association of Critical-Care Nurses.

  4. Human factors engineering guidance for the review of advanced alarm systems

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Brown, W.S.; Higgins, J.C.; Stubler, W.F.

    1994-09-01

    This report provides guidance to support the review of the human factors aspects of advanced alarm system designs in nuclear power plants. The report is organized into three major sections. The first section describes the methodology and criteria that were used to develop the design review guidelines. Also included is a description of the scope, organization, and format of the guidelines. The second section provides a systematic review procedure in which important characteristics of the alarm system are identified, described, and evaluated. The third section provides the detailed review guidelines. The review guidelines are organized according to important characteristics of the alarm system including: alarm definition; alarm processing and reduction; alarm prioritization and availability; display; control; automated; dynamic, and modifiable characteristics; reliability, test, maintenance, and failure indication; alarm response procedures; and control-display integration and layout

  5. Human factors engineering guidance for the review of advanced alarm systems

    Energy Technology Data Exchange (ETDEWEB)

    O`Hara, J.M.; Brown, W.S.; Higgins, J.C.; Stubler, W.F. [Brookhaven National Lab., Upton, NY (United States)

    1994-09-01

    This report provides guidance to support the review of the human factors aspects of advanced alarm system designs in nuclear power plants. The report is organized into three major sections. The first section describes the methodology and criteria that were used to develop the design review guidelines. Also included is a description of the scope, organization, and format of the guidelines. The second section provides a systematic review procedure in which important characteristics of the alarm system are identified, described, and evaluated. The third section provides the detailed review guidelines. The review guidelines are organized according to important characteristics of the alarm system including: alarm definition; alarm processing and reduction; alarm prioritization and availability; display; control; automated; dynamic, and modifiable characteristics; reliability, test, maintenance, and failure indication; alarm response procedures; and control-display integration and layout.

  6. Alarm reduction with correlation analysis; Larmsanering genom korrelationsanalys

    Energy Technology Data Exchange (ETDEWEB)

    Bergquist, Tord; Ahnlund, Jonas; Johansson, Bjoern; Gaardman, Lennart; Raaberg, Martin [Lund Univ. (Sweden). Dept. of Information Technology

    2004-09-01

    This project's main interest is to improve the overall alarm situation in the control rooms. By doing so, the operators working environment is less overstrained, which simplifies the decision-making. According to a study of the British refinery industry, the operators make wrong decisions in four times out of ten due to badly tuned alarm systems, with heavy expenses as a result. Furthermore, a more efficiently alarm handling is estimated to decrease the production loss with between three and eight percent. This sounds, according to Swedish standards, maybe a bit extreme, but there is no doubt about the benefits of having a well-tuned alarm system. This project can be seen as an extension of 'General Methods for Alarm Reduction' (VARMEFORSK--835), where the process improvements were the result of suggestions tailored for every signal. Here, instead causal dependences in the process are examined. A method for this, specially designed to fit process signals, has been developed. It is called MLPC (Multiple Local Property Correlation) and could be seen as an unprejudiced way of increase the information value in the process. There are a number of ways to make use of the additional process understanding a correlation analysis provides. In the report some are mentioned, foremost aiming to improve the alarm situation for operators. Signals from two heating plants have been analyzed with MLPC. In simulations, with the use of the result from these analyses as a base, a large number of alarms have been successfully suppressed. The results have been studied by personal with process knowledge, and they are very positive to the use of MLPC and they express many benefits by the clarification of process relations. It was established in 'General Methods for Alarm Reduction' that low pass filter are superior to mean value filter and time delay when trying to suppress alarms. As a result, a module for signal processing has been developed. The main purpose is

  7. Testing alarm resolution procedures in a fuel fabrication facility

    International Nuclear Information System (INIS)

    Smith, B.W.; Razvi, J.

    1984-07-01

    Process monitoring data can be used for generating material loss estimates. The intent of using process control data is to enhance nuclear material control and accounting for the timely detection and resolution of discrepancies. The purpose of an alarm resolution system is to distinguish between system errors and an actual loss of nuclear material. A study has been performed to develop and test a site-specific set of alarm resolution procedures. The results of the study are described and include the frequency of alarms, the causes of alarms, the type of resolution, and the modeling of loss estimates. 3 references, 2 figures, 2 tables

  8. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  9. Detection and classification of alarm threshold violations in condition monitoring systems working in highly varying operational conditions

    Science.gov (United States)

    Strączkiewicz, M.; Barszcz, T.; Jabłoński, A.

    2015-07-01

    All commonly used condition monitoring systems (CMS) enable defining alarm thresholds that enhance efficient surveillance and maintenance of dynamic state of machinery. The thresholds are imposed on the measured values such as vibration-based indicators, temperature, pressure, etc. For complex machinery such as wind turbine (WT) the total number of thresholds might be counted in hundreds multiplied by the number of operational states. All the parameters vary not only due to possible machinery malfunctions, but also due to changes in operating conditions and these changes are typically much stronger than the former ones. Very often, such a behavior may lead to hundreds of false alarms. Therefore, authors propose a novel approach based on parameterized description of the threshold violation. For this purpose the novelty and severity factors are introduced. The first parameter refers to the time of violation occurrence while the second one describes the impact of the indicator-increase to the entire machine. Such approach increases reliability of the CMS by providing the operator with the most useful information of the system events. The idea of the procedure is presented on a simulated data similar to those from a wind turbine.

  10. Detection and classification of alarm threshold violations in condition monitoring systems working in highly varying operational conditions

    International Nuclear Information System (INIS)

    Strączkiewicz, M; Barszcz, T; Jabłoński, A

    2015-01-01

    All commonly used condition monitoring systems (CMS) enable defining alarm thresholds that enhance efficient surveillance and maintenance of dynamic state of machinery. The thresholds are imposed on the measured values such as vibration-based indicators, temperature, pressure, etc. For complex machinery such as wind turbine (WT) the total number of thresholds might be counted in hundreds multiplied by the number of operational states. All the parameters vary not only due to possible machinery malfunctions, but also due to changes in operating conditions and these changes are typically much stronger than the former ones. Very often, such a behavior may lead to hundreds of false alarms. Therefore, authors propose a novel approach based on parameterized description of the threshold violation. For this purpose the novelty and severity factors are introduced. The first parameter refers to the time of violation occurrence while the second one describes the impact of the indicator-increase to the entire machine. Such approach increases reliability of the CMS by providing the operator with the most useful information of the system events. The idea of the procedure is presented on a simulated data similar to those from a wind turbine. (paper)

  11. Linear and nonlinear piezoelectric shunting strategies for vibration mitigation

    Directory of Open Access Journals (Sweden)

    Soltani P.

    2014-01-01

    Full Text Available This paper studies linear and nonlinear piezoelectric vibration absorbers that are designed based on the equal-peak method. A comparison between the performance of linear mechanical and electrical tuned vibration absorbers coupled to a linear oscillator is first performed. Nonlinearity is then introduced in the primary oscillator to which a new nonlinear electrical tuned vibration absorber is attached. Despite the frequency-energy dependence of nonlinear oscillations, we show that the nonlinear absorber is capable of effectively mitigating the vibrations of the nonlinear primary system in a large range of forcing amplitudes.

  12. 46 CFR 28.250 - High water alarms.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a) A...

  13. Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus).

    Science.gov (United States)

    Deng, Huaiqing; Gao, Kai; Zhou, Jiang

    2016-09-30

    Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002-2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7-10 min) followed by longer variable-frequency mobbing calls lasting 5-12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520-1000 Hz and 690-3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates' species. The system of vocal alarm behavior described in this critically endangered species is simple and effective.

  14. A Nuisance Alarm Data System for evaluation of intrusion detectors

    International Nuclear Information System (INIS)

    Ream, W.K.

    1990-01-01

    A Nuisance Alarm Data System (NADS) was developed to gather long-term background alarm data on exterior intrusion detectors as part of their evaluation. Since nuisance alarms play an important part in the selection of intrusion detectors for use at Department of Energy (DOE) facilities, an economical and reliable way to monitor and record these alarms was needed. NADS consists of an IBM personal computer and printer along with other commercial units to communicate with the detectors, to gather weather data, and to record video for assessment. Each alarm, its assessment, and the weather conditions occurring at alarm time are placed into a data base that is used in the evaluation of the detector. The operating software is written in Turbo Pascal for easy maintenance and modification. A portable system, based on the NADS design, has been built and shipped to other DOE locations to do on-site alarm monitoring. This has been valuable for the comparison of different detectors in the on-site environment and for testing new detectors when the appropriate conditions do not exist or cannot be simulated at the Exterior Intrusion Detection Testbed

  15. Reducing hospital noise: a review of medical device alarm management.

    Science.gov (United States)

    Konkani, Avinash; Oakley, Barbara; Bauld, Thomas J

    2012-01-01

    Increasing noise in hospital environments, especially in intensive care units (ICUs) and operating rooms (ORs), has created a formidable challenge for both patients and hospital staff. A major contributing factor for the increasing noise levels in these environments is the number of false alarms generated by medical devices. This study focuses on discovering best practices for reducing the number of false clinical alarms in order to increase patient safety and provide a quiet environment for both work and healing. The researchers reviewed Pub Med, Web of Knowledge and Google Scholar sources to obtain original journal research and review articles published through January 2012. This review includes 27 critically important journal articles that address different aspects of medical device alarms management, including the audibility, identification, urgency mapping, and response time of nursing staff and different solutions to such problems. With current technology, the easiest and most direct method for reducing false alarms is to individualize alarm settings for each patient's condition. Promoting an institutional culture change that emphasizes the importance of individualization of alarms is therefore an important goal. Future research should also focus on the development of smart alarms.

  16. Fault detection of a spur gear using vibration signal with multivariable statistical parameters

    Directory of Open Access Journals (Sweden)

    Songpon Klinchaeam

    2014-10-01

    Full Text Available This paper presents a condition monitoring technique of a spur gear fault detection using vibration signal analysis based on time domain. Vibration signals were acquired from gearboxes and used to simulate various faults on spur gear tooth. In this study, vibration signals were applied to monitor a normal and various fault conditions of a spur gear such as normal, scuffing defect, crack defect and broken tooth. The statistical parameters of vibration signal were used to compare and evaluate the value of fault condition. This technique can be applied to set alarm limit of the signal condition based on statistical parameter such as variance, kurtosis, rms and crest factor. These parameters can be used to set as a boundary decision of signal condition. From the results, the vibration signal analysis with single statistical parameter is unclear to predict fault of the spur gears. The using at least two statistical parameters can be clearly used to separate in every case of fault detection. The boundary decision of statistical parameter with the 99.7% certainty ( 3   from 300 referenced dataset and detected the testing condition with 99.7% ( 3   accuracy and had an error of less than 0.3 % using 50 testing dataset.

  17. Space shuttle main engine vibration data base

    Science.gov (United States)

    Lewallen, Pat

    1986-01-01

    The Space Shuttle Main Engine Vibration Data Base is described. Included is a detailed description of the data base components, the data acquisition process, the more sophisticated software routines, and the future data acquisition methods. Several figures and plots are provided to illustrate the various output formats accessible to the user. The numerous vibration data recall and analysis capabilities available through automated data base techniques are revealed.

  18. Measurement of the Portsmouth Gaseous Diffusion Plant criticality accident alarm

    International Nuclear Information System (INIS)

    Tayloe, R.W. Jr.; D'Aquila, D.M.; McGinnis, R.B.

    1991-01-01

    The nuclear criticality accident radiation alarm system installed at the Portsmouth Gaseous Diffusion Plant was tested extensively at critical facilities located at the Los Alamos National Laboratory. The ability of the neutron scintillator radiation detection units to respond to a minimum accident of concern as defined in Standard ANSI/ANS-83.-1986 was demonstrated. Detector placement and the established trip point are based on shielding calculations performed by the Oak Ridge National Laboratory and criticality specialists at the Portsmouth plant. Based on these experiments and calculations, a detector trip point of 5 mrad/h in air is used. Any credible criticality accident is expected to produce neutron radiation fields >5 mrad/h in air at one or more radiation alarm locations. Each radiation alarm location has a cluster of three detectors that employs a two-out-of-three alarm logic. Earlier work focused on testing the alarm logic latching circuitry. This work was directed toward measurements involving the actual audible alarm signal delivered

  19. Expert system for the real-time management of alarms in an electric grid. Un systeme expert pour la gestion en temps reel des alarmes dans un reseau electrique

    Energy Technology Data Exchange (ETDEWEB)

    Girouard, P.

    1987-01-01

    A model-base expert system is presented for the processing of alarm messages in power networks' control centers. This alarm processor, called GESTAL, generates concise diagnoses identifying the causes(s) of network disturbances and describing the operation of the protection and alarm systems which operate to isolate faulty components. Essentially, the alarm processor is an agenda driven expert system which is composed of a model of the power network's alarm and protection systems as well as several sets of rules. Based on the nextwork model, graph structures are constructed which represent relationships between alarms as they are received. These graph structures are then analysed in order to diagnose the disturbances(s). The alarm processor has been developed using the ART 3.0 programming language in a Symbolics Lisp-machine environment. Background material on expert systems, electric power networks, and alarm processing software is included, as well as a description of GESTAL'S functional characteristics and design. 51 refs., 28 figs.

  20. Benefits of Spacecraft Level Vibration Testing

    Science.gov (United States)

    Gordon, Scott; Kern, Dennis L.

    2015-01-01

    NASA-HDBK-7008 Spacecraft Level Dynamic Environments Testing discusses the approaches, benefits, dangers, and recommended practices for spacecraft level dynamic environments testing, including vibration testing. This paper discusses in additional detail the benefits and actual experiences of vibration testing spacecraft for NASA Goddard Space Flight Center (GSFC) and Jet Propulsion Laboratory (JPL) flight projects. JPL and GSFC have both similarities and differences in their spacecraft level vibration test approach: JPL uses a random vibration input and a frequency range usually starting at 5 Hz and extending to as high as 250 Hz. GSFC uses a sine sweep vibration input and a frequency range usually starting at 5 Hz and extending only to the limits of the coupled loads analysis (typically 50 to 60 Hz). However, both JPL and GSFC use force limiting to realistically notch spacecraft resonances and response (acceleration) limiting as necessary to protect spacecraft structure and hardware from exceeding design strength capabilities. Despite GSFC and JPL differences in spacecraft level vibration test approaches, both have uncovered a significant number of spacecraft design and workmanship anomalies in vibration tests. This paper will give an overview of JPL and GSFC spacecraft vibration testing approaches and provide a detailed description of spacecraft anomalies revealed.

  1. Evaluating late detection capability against diverse insider adversaries

    International Nuclear Information System (INIS)

    Sicherman, A.

    1987-01-01

    The threat of theft or diversion of special nuclear material (SNM) by insiders is a key concern for safeguards planners. Different types of employees having varying degrees of access to both SNM and safeguards systems pose a difficult challenge for theft detection. Safeguards planners rely on physical security, material control, and accountability to provide detection of a theft attempt. When detection occurs too late to prevent a theft, it is called a late detection or late alarm. Activities or events that many provide late detection usually belong to material control and accountability (MC ampersand A) activities. A model has been developed for evaluating the probability of late detection as a function of time elapsed since the theft. Late detection capability is beneficial if it is timely enough to improve the ability to determine the cause of an alarm, speed recovery of SNM, prevent an incorrect response to a threat demand, or promote assurance that no theft has occurred in the absence of an alarm. The model provides insight into the effectiveness of late detection safeguards components in place and helps to identify areas where the MC ampersand A can be most effectively improved

  2. Ship cabin leakage alarm based on ARM SCM

    Science.gov (United States)

    Qu, Liyan

    2018-03-01

    If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.

  3. SeaQuest/E906 Shift Alarm System

    Science.gov (United States)

    Kitts, Noah

    2014-09-01

    SeaQuest, Fermilab E906, is a fixed target experiment that measures the Drell-Yan cross-section ratio of proton-proton to proton-deuterium collisions in order to extract the sea anti-quark structure of the proton. SeaQuest will extend the measurements made by E866/NuSea with greater precision at higher Bjorken-x. The continuously running experiment is always being monitored. Those on shift must keep track of all of the detector readouts in order to make sure the experiment is running correctly. As an experiment that is still in its early stages of running, an alarm system for people on shift is being created to provide warnings, such as a plot showing a detector's performance is sufficiently different to need attention. This plan involves python scripts that track live data. When the data shows a problem within the experiment, a corresponding alarm ID is sent to the MySQL database which then sets off an alarm. These alarms, which will alert the person on shift through both an audible and visual response, are important for ensuring that issues do not go unnoticed, and to help make sure the experiment is recording good data.

  4. Coincidence logic modules for criticality alarming

    International Nuclear Information System (INIS)

    Schaief, C.C. III.

    1977-04-01

    A coincidence Logic Module and a companion contact closure Relay Module utilizing the NIM Standard have been developed for criticality alarming. The units provide an ALARM whenever two or more out of N detectors become activated. In addition, an ALERT is generated whenever one or more detectors is activated or when certain electronic component failures occur. The number of detector inputs (N) can be expanded in groups of six by adding modules. Serial and parallel redundancy were used to reduce the probability of system failure

  5. 76 FR 69321 - Petition to Modify an Exemption of a Previously Approved Antitheft Device; Porsche

    Science.gov (United States)

    2011-11-08

    ... diagnostic capabilities to accept inputs such as motion sensors and an alarm control unit that monitored the... interference tests, vibration tests and endurance tests. Porsche stated that its antitheft device also features a built- in self-diagnostic that constantly checks for system failures. If a failure is detected...

  6. Understanding heart rate alarm adjustment in the intensive care units through an analytical approach.

    Directory of Open Access Journals (Sweden)

    Richard L Fidler

    Full Text Available Heart rate (HR alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue.To understand the relationship between heart rate (HR alarms and adjustments to reduce unnecessary heart rate alarms.Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm. The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server.There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57.HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision.

  7. General multiplex centralized fire-alarm display system

    International Nuclear Information System (INIS)

    Zhu Liqun; Chen Jinming

    2002-01-01

    The fire-alarm display system is developed, which can connect with each type of fire controllers produced in the factory and SIGMASYS controllers. It can display whole alarm information. The display system software gathers communication, database and multimedia, has functions of inspecting fire, showing alarm, storing data, searching information and so on. The drawing software lets the user expediently add, delete, move and modify fire detection or fire fighting facilities on the building floor maps. The graphic transform software lets the display use the vectorgraph produced by popular plotting software such as Auto CAD. The system software provides the administration function, such as log book of changing shift and managing workers etc.. The software executed on Windows 98 platform. The user interface is friendly and reliable in operation

  8. Development of alarm handling methods for boiling water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yukiharu, Ohga; Hiroshi, Seki; Setsuo, Arita [Power and Industrial Systems R and D Div., Hitachi, Ltd., Hitachi, Ibaraki (Japan)

    1997-09-01

    A method was developed to select important alarms in two steps: first, selection is based on the physical relationship between the alarms, and second, selection is according to the initial event. An approach combining a neural network and knowledge processing was proposed to identify the event rapidly. A prototype system was evaluated in the Kashiwazaki/Kariwa-4 Nuclear Power Plant during the startup test. The evaluation test confirmed that about 30% of the alarms are selected from among the many activated alarms. The second method, dealing with presentation, supports operators in their selection and confirmation of the required information for plant operation. The method selects and offers plant information in response to plant status changes and operators` demands. The selection procedure is based on the knowledge and data as structured by the plant functional structure; i.e. a means-ends abstraction hierarchy model. A prototype system was evaluated using a BWR simulator. The results showed that appropriate information items are automatically selected according to plant status changes and information on generated alarms is presented to operators together with the related trend graph and system diagram. Answers are generated in reply to the operators` demands and operators can confirm the generated alarms on each plant function, such as systems and components. 8 refs, 10 figs, 2 tabs.

  9. Development of alarm handling methods for boiling water reactors

    International Nuclear Information System (INIS)

    Ohga Yukiharu; Seki Hiroshi; Arita Setsuo

    1997-01-01

    A method was developed to select important alarms in two steps: first, selection is based on the physical relationship between the alarms, and second, selection is according to the initial event. An approach combining a neural network and knowledge processing was proposed to identify the event rapidly. A prototype system was evaluated in the Kashiwazaki/Kariwa-4 Nuclear Power Plant during the startup test. The evaluation test confirmed that about 30% of the alarms are selected from among the many activated alarms. The second method, dealing with presentation, supports operators in their selection and confirmation of the required information for plant operation. The method selects and offers plant information in response to plant status changes and operators' demands. The selection procedure is based on the knowledge and data as structured by the plant functional structure; i.e. a means-ends abstraction hierarchy model. A prototype system was evaluated using a BWR simulator. The results showed that appropriate information items are automatically selected according to plant status changes and information on generated alarms is presented to operators together with the related trend graph and system diagram. Answers are generated in reply to the operators' demands and operators can confirm the generated alarms on each plant function, such as systems and components. 8 refs, 10 figs, 2 tabs

  10. Calculation of ground vibration spectra from heavy military vehicles

    Science.gov (United States)

    Krylov, V. V.; Pickup, S.; McNuff, J.

    2010-07-01

    The demand for reliable autonomous systems capable to detect and identify heavy military vehicles becomes an important issue for UN peacekeeping forces in the current delicate political climate. A promising method of detection and identification is the one using the information extracted from ground vibration spectra generated by heavy military vehicles, often termed as their seismic signatures. This paper presents the results of the theoretical investigation of ground vibration spectra generated by heavy military vehicles, such as tanks and armed personnel carriers. A simple quarter car model is considered to identify the resulting dynamic forces applied from a vehicle to the ground. Then the obtained analytical expressions for vehicle dynamic forces are used for calculations of generated ground vibrations, predominantly Rayleigh surface waves, using Green's function method. A comparison of the obtained theoretical results with the published experimental data shows that analytical techniques based on the simplified quarter car vehicle model are capable of producing ground vibration spectra of heavy military vehicles that reproduce basic properties of experimental spectra.

  11. SUBSURFACE VISUAL ALARM SYSTEM ANALYSIS

    International Nuclear Information System (INIS)

    D.W. Markman

    2001-01-01

    The ''Subsurface Fire Hazard Analysis'' (CRWMS M andO 1998, page 61), and the document, ''Title III Evaluation Report for the Surface and Subsurface Communication System'', (CRWMS M andO 1999a, pages 21 and 23), both indicate the installed communication system is adequate to support Exploratory Studies Facility (ESF) activities with the exception of the mine phone system for emergency notification purposes. They recommend the installation of a visual alarm system to supplement the page/party phone system The purpose of this analysis is to identify data communication highway design approaches, and provide justification for the selected or recommended alternatives for the data communication of the subsurface visual alarm system. This analysis is being prepared to document a basis for the design selection of the data communication method. This analysis will briefly describe existing data or voice communication or monitoring systems within the ESF, and look at how these may be revised or adapted to support the needed data highway of the subsurface visual alarm. system. The existing PLC communication system installed in subsurface is providing data communication for alcove No.5 ventilation fans, south portal ventilation fans, bulkhead doors and generator monitoring system. It is given that the data communication of the subsurface visual alarm system will be a digital based system. It is also given that it is most feasible to take advantage of existing systems and equipment and not consider an entirely new data communication system design and installation. The scope and primary objectives of this analysis are to: (1) Briefly review and describe existing available data communication highways or systems within the ESF. (2) Examine technical characteristics of an existing system to disqualify a design alternative is paramount in minimizing the number of and depth of a system review. (3) Apply general engineering design practices or criteria such as relative cost, and degree

  12. Differences in alarm events between disposable and reusable electrocardiography lead wires.

    Science.gov (United States)

    Albert, Nancy M; Murray, Terri; Bena, James F; Slifcak, Ellen; Roach, Joel D; Spence, Jackie; Burkle, Alicia

    2015-01-01

    Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. To examine differences in alarm events between disposable and reusable ECG-LWs. Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, assessed frequency and type of alarm events by using total counts and rates per 100 patient days. Event rates were compared by using generalized linear mixed-effect models for differences and noninferiority between wire types. In 1611 patients and 9385.5 patient days of ECG monitoring, patient characteristics were similar between groups. Rates of alarms for no telemetry, leads fail, or leads off were lower in disposable ECG-LWs (adjusted relative risk [95% CI], 0.71 [0.53-0.96]; noninferiority P < .001; superiority P = .03) and monitoring (artifact) alarms were significantly noninferior (adjusted relative risk [95% CI]: 0.88, [0.62-1.24], P = .02; superiority P = .44). No between-group differences existed in false or true crisis alarms. Disposable ECG-LWs were noninferior to reusable ECG-LWs for all false-alarm events (N [rate per 100 patient days], disposable 2029 [79.1] vs reusable 6673 [97.9]; adjusted relative risk [95% CI]: 0.81 [0.63-1.06], P = .002; superiority P = .12.) Disposable ECG-LWs with patented push-button design had superior performance in reducing alarms created by no telemetry, leads fail, or leads off and significant noninferiority in all false-alarm rates compared with reusable ECG-LWs. Fewer ECG alarms may save nurses time, decrease alarm fatigue, and improve patient safety. ©2015 American Association of Critical-Care Nurses.

  13. Judging the urgency of non-verbal auditory alarms: a case study.

    Science.gov (United States)

    Arrabito, G Robert; Mondor, Todd; Kent, Kimberley

    2004-06-22

    When designed correctly, non-verbal auditory alarms can convey different levels of urgency to the aircrew, and thereby permit the operator to establish the appropriate level of priority to address the alarmed condition. The conveyed level of urgency of five non-verbal auditory alarms presently used in the Canadian Forces CH-146 Griffon helicopter was investigated. Pilots of the CH-146 Griffon helicopter and non-pilots rated the perceived urgency of the signals using a rating scale. The pilots also ranked the urgency of the alarms in a post-experiment questionnaire to reflect their assessment of the actual situation that triggers the alarms. The results of this investigation revealed that participants' ratings of perceived urgency appear to be based on the acoustic properties of the alarms which are known to affect the listener's perceived level of urgency. Although for 28% of the pilots the mapping of perceived urgency to the urgency of their perception of the triggering situation was statistically significant for three of the five alarms, the overall data suggest that the triggering situations are not adequately conveyed by the acoustic parameters inherent in the alarms. The pilots' judgement of the triggering situation was intended as a means of evaluating the reliability of the alerting system. These data will subsequently be discussed with respect to proposed enhancements in alerting systems as it relates to addressing the problem of phase of flight. These results call for more serious consideration of incorporating situational awareness in the design and assignment of auditory alarms in aircraft.

  14. Alarm systems in the nuclear industry - survey of the working situation and identification of future research issues

    International Nuclear Information System (INIS)

    Joensson, Anna; Osvalder, Anna-Lisa; Holmstroem, Conny; Dahlman, Sven

    2004-01-01

    Safety issues are important in the control of industrial processes. An essential part for interpreting and avoiding hazardous situations is the alarm system and its design. To increase the knowledge and to develop new design solutions this doctoral project was initiated. The work has been divided into three stages and this paper presents the results of the first stage. The objective of stage one was to investigate how operators in both nuclear and non-nuclear plants work. A comparison between different branches of industry was also performed. From these results a future research issue has been identified. The methods used were observations, interviews and a literature study. The results showed that the operators are satisfied with the performance of the alarm system during normal operating conditions. However, several problems could also be identified but most of them are already well-known in the nuclear industry. Since these problems are well known but still exist, this result contributes to the basic hypothesis that a theoretical basis is lacking for the design of the alarm system. The proposed issue for forthcoming work is therefore to collect and compile existing knowledge about the human information processing and alarm systems, and combine the knowledge from these areas. With a better understanding of the relation between these areas it is possible to develop new design solutions which are better adapted to the human capabilities and limitations. This would support operator performance which in turn increases plant performance and safety. (Author)

  15. Earthquake Early Warning Management based on Client-Server using Primary Wave data from Vibrating Sensor

    Science.gov (United States)

    Laumal, F. E.; Nope, K. B. N.; Peli, Y. S.

    2018-01-01

    Early warning is a warning mechanism before an actual incident occurs, can be implemented on natural events such as tsunamis or earthquakes. Earthquakes are classified in tectonic and volcanic types depend on the source and nature. The tremor in the form of energy propagates in all directions as Primary and Secondary waves. Primary wave as initial earthquake vibrations propagates longitudinally, while the secondary wave propagates like as a sinusoidal wave after Primary, destructive and as a real earthquake. To process the primary vibration data captured by the earthquake sensor, a network management required client computer to receives primary data from sensors, authenticate and forward to a server computer to set up an early warning system. With the water propagation concept, a method of early warning system has been determined in which some sensors are located on the same line, sending initial vibrations as primary data on the same scale and the server recommended to the alarm sound as an early warning.

  16. Alarm pocket dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, H; Kitamura, S [Matsushita Electric Industrial Co. Ltd., Kadoma, Osaka (Japan)

    1975-04-01

    This instrument is a highly reliable pocket dosimeter which has been developed for personal monitoring use. The dosimeter generates an alarm sound when the exposure dose reaches a preset value. Using a tiny GM tube for a radiation detector and measuring the integrated dose by means of a digital counting method, this new pocket dosimeter has high accuracy and stability. Using a sealed alkali storage battery for the power supply, and with an automatic control charger, this dosimetry system is easy and economical to operate and maintain. Detectable radiation by the dosimeter are X and ..gamma.. rays. Standard preset dose values are 30, 50, 80 and 100 mR. Detection accuracy is betwen +10% and -20%. The dosimeter is continuously usable for more than 14 hours after charging for 2 hours. The dosimeter has the following features; good realiability, shock-proof loud and clear alarm sound, the battery charger also serves as a stock container for the dosimeters, and no switching operation required for the power supply due to the internal automatic switch. Therefore, the dosimetry system is very useful for personal monitoring management in many radiation industry establishments.

  17. Attributions of cancer 'alarm' symptoms in a community sample.

    Directory of Open Access Journals (Sweden)

    Katriina L Whitaker

    Full Text Available Attribution of early cancer symptoms to a non-serious cause may lead to longer diagnostic intervals. We investigated attributions of potential cancer 'alarm' and non-alarm symptoms experienced in everyday life in a community sample of adults, without mention of a cancer context.A questionnaire was mailed to 4858 adults (≥50 years old, no cancer diagnosis through primary care, asking about symptom experiences in the past 3 months. The word cancer was not mentioned. Target 'alarm' symptoms, publicised by Cancer Research UK, were embedded in a longer symptom list. For each symptom experienced, respondents were asked for their attribution ('what do you think caused it', concern about seriousness ('not at all' to 'extremely', and help-seeking ('did you contact a doctor about it': Yes/No.The response rate was 35% (n = 1724. Over half the respondents (915/1724; 53% had experienced an 'alarm' symptom, and 20 (2% cited cancer as a possible cause. Cancer attributions were highest for 'unexplained lump'; 7% (6/87. Cancer attributions were lowest for 'unexplained weight loss' (0/47. A higher proportion (375/1638; 23% were concerned their symptom might be 'serious', ranging from 12% (13/112 for change in a mole to 41% (100/247 for unexplained pain. Just over half had contacted their doctor about their symptom (59%, although this varied by symptom. Alarm symptoms were appraised as more serious than non-alarm symptoms, and were more likely to trigger help-seeking.Consistent with retrospective reports from cancer patients, 'alarm' symptoms experienced in daily life were rarely attributed to cancer. These results have implications for understanding how people appraise and act on symptoms that could be early warning signs of cancer.

  18. Pickin’ up good vibrations

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    In preparation for the civil engineering work on the HL-LHC, vibration measurements were carried out at the LHC’s Point 1 last month. These measurements will help evaluate how civil engineering work could impact the beam, and will provide crucial details about the site’s geological make-up before construction begins.   A seismic truck at Point 1 generated wave-like vibrations measured by EN/MME. From carrying out R&D to produce state-of-the-art magnets to developing innovative, robust materials capable of withstanding beam impact, the HL-LHC is a multi-faceted project involving many groups and teams across CERN’s departments. It was in this framework that the project management mandated CERN's Mechanical and Materials Engineering (EN/MME) group to measure the propagation of vibrations around Point 1. Their question: can civil engineering work for the HL-LHC – the bulk of which is scheduled for LS2 – begin while the LHC is running? Alth...

  19. Design of SMART alarm system using main memory database

    International Nuclear Information System (INIS)

    Jang, Kue Sook; Seo, Yong Seok; Park, Keun Oak; Lee, Jong Bok; Kim, Dong Hoon

    2001-01-01

    To achieve design goal of SMART alarm system, first of all we have to decide on how to handle and manage alarm information and how to use database. So this paper analyses concepts and deficiencies of main memory database applied in real time system. And this paper sets up structure and processing principles of main memory database using nonvolatile memory such as flash memory and develops recovery strategy and process board structures using these. Therefore this paper shows design of SMART alarm system is suited functions and requirements

  20. Ultrasonic Technology in Duress Alarms.

    Science.gov (United States)

    Lee, Martha A.

    2000-01-01

    Provides the pros and cons of the most commonly used technologies in personal duress alarm systems in the school environment. Discussed are radio frequency devices, infrared systems, and ultrasonic technology. (GR)

  1. 46 CFR 97.37-50 - Ventilation alarm failure.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The...-inch letters “VENTILATION FAILURE IN VEHICULAR SPACE.” (b) [Reserved] [CGFR 66-33, 31 FR 15286, Dec. 6...

  2. A study of reset mode in advanced alarm system simulator

    International Nuclear Information System (INIS)

    Yenn, T. C.; Hwang, S. L.; Huang, F. H.; Yu, A. C.; Hsu, C. C.; Huang, H. W.

    2006-01-01

    An automation function has been widely applied in main control room of nuclear power plants. That leads to a new issue of human-automation interaction, which considers human operational performance in automated systems. In this research is the automation alarm reset in the advanced alarm system (AAS) of Advanced Nuclear Power Plant in Taiwan. Since alarms are very crucial for the understanding of the status of the plant as well as the reset function of alarm system will be changed from fully manual to fully automatic, it is very important to test and evaluate the performance and the effect of reset modes in AAS. The purpose of this paper is to evaluate the impact of the auto-reset alarm system on the plant performance and on operators' preference and task load. To develop a dynamic simulator as an AAS was conducted to compare manual and automatic reset function of alarm system on task performance and subjective ratings of task workload, comprehension, and preference. The simulation includes PCTRAN model and alarm software processing. The final results revealed that, using the auto-reset mode, participants had lower task load index (TLX) on effort in the first test trial and was more satisfied in multiple tasks condition. In contrast, using manual reset mode, participants were more satisfied on alarm handling, monitoring, and decision making. In other words, either reset mode in the study has unique features to assist operator, but is insufficient. The reset function in AAS therefore should be very flexible. Additionally, the experimental results also pointed out that the user interfaces need to be improved. Those experiences will be helpful for human factors verification and validation in the near future. (authors)

  3. Development experience and strategy for the combined algorithm on the alarm processing and diagnosis

    International Nuclear Information System (INIS)

    Chung, Hak-Yeong

    1997-01-01

    In this paper, I presented the development experience on the alarm processing and fault diagnosis which has been achieved from early 1988 to late 1995. The scope covered is the prototype stage, the development stage of on-line operator-aid system, and an intelligent human-machine interface system. In the second part, I proposed a new method (APEXS) of multi-alarm processing to select the causal alarm(s) among occurred alarms by using the time information of each occurred alarm and alarm tree knowledge and the corresponding diagnosis method based on the selected causal alarm(s) by using the prescribed qualitative model. With more knowledge base about the plant and some modification suitable for real environment, APEXS will be able to adapt to a real steam power plant. (author). 18 refs, 3 figs, 1 tab

  4. Reduction of false arrhythmia alarms using signal selection and machine learning

    NARCIS (Netherlands)

    Eerikäinen, L.M.; Vanschoren, J.; Rooijakkers, M.J.; Vullings, R.; Aarts, R.M.

    2016-01-01

    In this paper, we propose an algorithm that classifies whether a generated cardiac arrhythmia alarm is true or false. The large number of false alarms in intensive care is a severe issue. The noise peaks caused by alarms can be high and in a noisy environment nurses can experience stress and

  5. Nuthatches eavesdrop on variations in heterospecific chickadee mobbing alarm calls

    Science.gov (United States)

    Templeton, Christopher N.; Greene, Erick

    2007-01-01

    Many animals recognize the alarm calls produced by other species, but the amount of information they glean from these eavesdropped signals is unknown. We previously showed that black-capped chickadees (Poecile atricapillus) have a sophisticated alarm call system in which they encode complex information about the size and risk of potential predators in variations of a single type of mobbing alarm call. Here we show experimentally that red-breasted nuthatches (Sitta canadensis) respond appropriately to subtle variations of these heterospecific “chick-a-dee” alarm calls, thereby evidencing that they have gained important information about potential predators in their environment. This study demonstrates a previously unsuspected level of discrimination in intertaxon eavesdropping. PMID:17372225

  6. A weighted dissimilarity index to isolate faults during alarm floods

    CERN Document Server

    Charbonnier, S; Gayet, P

    2015-01-01

    A fault-isolation method based on pattern matching using the alarm lists raised by the SCADA system during an alarm flood is proposed. A training set composed of faults is used to create fault templates. Alarm vectors generated by unknown faults are classified by comparing them with the fault templates using an original weighted dissimilarity index that increases the influence of the few alarms relevant to diagnose the fault. Different decision strategies are proposed to support the operator in his decision making. The performances are evaluated on two sets of data: an artificial set and a set obtained from a highly realistic simulator of the CERN Large Hadron Collider process connected to the real CERN SCADA system.

  7. Isolation of a pyrazine alarm pheromone component from the fire ant, Solenopsis invicta.

    Science.gov (United States)

    Vander Meer, Robert K; Preston, Catherine A; Choi, Man-Yeon

    2010-02-01

    Alarm pheromones in social insects are an essential part of a complex of pheromone interactions that contribute to the maintenance of colony integrity and sociality. The alarm pheromones of ants were among the first examples of animal pheromones identified, primarily because of the large amount of chemical produced and the distinctive responses of ants to the pheromone. However, the alarm pheromone of the fire ant, Solenopsis invicta, eluded identification for over four decades. We identified 2-ethyl-3,6-dimethylpyrazine as an alarm pheromone component of S. invicta. Worker fire ants detect the pyrazine alarm pheromone at 30 pg/ml, which is comparable to alarm pheromone sensitivities reported for other ant species. The source of this alarm pheromone are the mandibular glands, which, in fire ants, are not well developed and contain only about 300 pg of the compound, much less than the microgram quantities of alarm pheromones reported for several other ant species. Female and male sexuals and workers produce the pyrazine, which suggests that it may be involved in fire ant mating flight initiation, as well as the typical worker alarm response. This is the first report of 2-ethyl-3,6-dimethylpyrazine from a Solenopsis species and the first example of this alkaloid functioning as an alarm pheromone.

  8. Minimum detectable activity and false alarm rate relationships for alpha continuous air monitors

    International Nuclear Information System (INIS)

    Hoover, M.D.; Newton, G.J.

    1994-01-01

    The U.S. Department of Energy rule for Occupational Radiation Protection (10 CFR Part 835, December 1993) and the DOE Radiological Control Manual (the RCM) (DOE/EH-0256T, Rev. 1, April 1994) require the use of continuous air monitors (CAMs) in normally occupied areas where an individual is likely to be exposed to a concentration of airborne radioactivity exceeding the derived air concentration (DAC) or where there is a need to alert potentially exposed individuals to unexpected increases in airborne radioactivity levels. The DAC is the airborne concentration that equals the annual limit on intake divided by the volume of air breathed by an average worker for a working year of 2000 h (assuming a breathing volume of 2400 m 3 ). It is equivalent to the airborne concentration to which a worker could be exposed for an entire working year (2000 h) without exceeding the allowable annual limit on intake. The rule and the RCM further require that real-time air monitors have an alarm capability and sufficient sensitivity to alert potentially exposed individuals that immediate action is necessary in order to minimize or terminate inhalation exposures. The RCM also recommends that real-time air monitors should be capable of measuring 1 DAC when averaged over 8 h (8 DAC-h) under laboratory conditions. In response to these recommendations, we are developing procedures for determining the basic sensitivity of alpha CAMs under laboratory conditions and for documenting practical alarm set points for routine use of CAMs under a range of radon and thoron concentrations

  9. Project 93L-EWL-097, fire alarm system improvements, 300 Area

    International Nuclear Information System (INIS)

    Scott, M.V.

    1995-01-01

    This document contains the Acceptance Test Procedure (ATP) which will demonstrate that the modifications to the Fire Protection systems in the 338 Building function as intended. The ATP will test the fire alarm control panel, flow alarm pressure switch, post indicator valve tamper switch, heat detectors, flow switches, and fire alarm signaling devices

  10. Alarm pheromone processing in the ant brain: an evolutionary perspective

    Directory of Open Access Journals (Sweden)

    Makoto Mizunami

    2010-06-01

    Full Text Available Social insects exhibit sophisticated communication by means of pheromones, one example of which is the use of alarm pheromones to alert nestmates for colony defense. We review recent advances in the understanding of the processing of alarm pheromone information in the ant brain. We found that information about formic acid and n-undecane, alarm pheromone components, is processed in a set of specific glomeruli in the antennal lobe of the ant Camponotus obscuripes. Alarm pheromone information is then transmitted, via projection neurons, to the lateral horn and the calyces of the mushroom body of the protocerebrum. In the lateral horn, we found a specific area where terminal boutons of alarm pheromone-sensitive projection neurons are more densely distributed than in the rest of the lateral horn. Some neurons in the protocerebrum responded specifically to formic acid or n-undecane and they may participate in the control of behavioral responses to each pheromone component. Other neurons, especially those originating from the mushroom body lobe, responded also to non-pheromonal odors and may play roles in integration of pheromonal and non-pheromonal signals. We found that a class of neurons receive inputs in the lateral horn and the mushroom body lobe and terminate in a variety of premotor areas. These neurons may participate in the control of aggressive behavior, which is sensitized by alarm pheromones and is triggered by non-pheromonal sensory stimuli associated with a potential enemy. We propose that the alarm pheromone processing system has evolved by differentiation of a part of general odor processing system.

  11. Speech Alarms Pilot Study

    Science.gov (United States)

    Sandor, A.; Moses, H. R.

    2016-01-01

    Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were

  12. Development of a criticality monitoring and alarm system

    International Nuclear Information System (INIS)

    Egey, Julio; Izraelevitch, Federico H.; Matatagui, Emilio

    2009-01-01

    In this work we are presenting the development of a Criticality Monitor and Alarm System (SIMAC). It monitors the burst of radiation produced during such an accident and triggers an alarm for evacuation in case the radiation exceeds a pre-established threshold. It consists of two subsystems, one for gamma rays and the other for neutrons. Each subsystem has three independent detectors modules. Each module is composed of an ion chamber plus its associated electronics, feeding a logic module that in turn would trigger the evacuation alarm. An additional feature is a PC interface for data acquisition. The radiation detectors are ion chambers working in current mode. The electronics associated to each detector can manage a wide signal range using a logarithmic converter. (author)

  13. An evaluation approach for alarm processing improvement

    International Nuclear Information System (INIS)

    Kim, Jung-Taek; Lee, Dong-Young; Hwang, In-Koo; Park, Jae-Chang

    1997-01-01

    In light of the need to improve MMIS of NPPs, the advanced I and C research team of KAERI has embarked on developing an Alarm and Diagnosis-Integrated Operator Support System, called ADIOS, to filter or suppress unnecessary or nuisance alarms and diagnose abnormality of the plant process. ADIOS has been built in an object-oriented AI environment of G-2 expert system software tool, as presented in a companion paper. ADIOS then is evaluated according to the plan in three steps; (1) preliminary tests to refine the knowledge base and inference structure of ADIOS in such a dynamic environment, and also to evaluate the appropriateness of alarm-processing algorithms; (2) to ensure correctness, consistency, and completeness in the knowledge base using COKEP (Checker Of Knowledge base using Extended Petri net); and (3) the cognitive performance evaluation using the Simulation Analyzer with a Cognitive Operator Model (SACOM) in the KAERI's Integrated Test Facility (ITF). (author). 5 figs, 1 tab

  14. INEL test reactor facility alarms: descriptions, technical specifications, and modification procedure

    International Nuclear Information System (INIS)

    Potash, L.M.; Boone, M.P.

    1980-04-01

    This report identifies standards, procedures, and practices which will affect any attempt to integrate or introduce human engineering principles into nuclear power plant alarm systems. Additional information concerning type of signal used, expected reaction, type of sensor, etc., is presented because of its relevance to future work on alarm system integration. The INEL test reactors were studied. Interviews were conducted with operators, designers, and management personnel. Additional information was obtained from available documentation. Only fire-alarm systems, and to a lesser extent, criticality alarms, have detailed industry-wide standards. One general standard has been written for control-room annunciators

  15. AN AUTOMATIC CAR ANTI-THEFT ALARM SYSTEM

    OpenAIRE

    J. A. Enokela; E.J. Ibanga

    2007-01-01

    The theft of cars and other automobiles by criminals has become so frequent in our society as to be classified as alarming. Most of the thefts are organized by gangs of robbers but sometimes individuals engage in this activity. The result usually, however, is that the persons from whom the vehicles have been stolen are left to grieve as many of these vehicles are never recovered. This paper describes a simple alarm system that can be easily installed in all kinds of vehicles. The system desc...

  16. A False Alarm Reduction Method for a Gas Sensor Based Electronic Nose

    Directory of Open Access Journals (Sweden)

    Mohammad Mizanur Rahman

    2017-09-01

    Full Text Available Electronic noses (E-Noses are becoming popular for food and fruit quality assessment due to their robustness and repeated usability without fatigue, unlike human experts. An E-Nose equipped with classification algorithms and having open ended classification boundaries such as the k-nearest neighbor (k-NN, support vector machine (SVM, and multilayer perceptron neural network (MLPNN, are found to suffer from false classification errors of irrelevant odor data. To reduce false classification and misclassification errors, and to improve correct rejection performance; algorithms with a hyperspheric boundary, such as a radial basis function neural network (RBFNN and generalized regression neural network (GRNN with a Gaussian activation function in the hidden layer should be used. The simulation results presented in this paper show that GRNN has more correct classification efficiency and false alarm reduction capability compared to RBFNN. As the design of a GRNN and RBFNN is complex and expensive due to large numbers of neuron requirements, a simple hyperspheric classification method based on minimum, maximum, and mean (MMM values of each class of the training dataset was presented. The MMM algorithm was simple and found to be fast and efficient in correctly classifying data of training classes, and correctly rejecting data of extraneous odors, and thereby reduced false alarms.

  17. The challenge of localizing vehicle backup alarms: Effects of passive and electronic hearing protectors, ambient noise level, and backup alarm spectral content

    Directory of Open Access Journals (Sweden)

    Khaled A Alali

    2011-01-01

    Full Text Available A human factors experiment employed a hemi-anechoic sound field in which listeners were required to localize a vehicular backup alarm warning signal (both a standard and a frequency-augmented alarm in 360-degrees azimuth in pink noise of 60 dBA and 90 dBA. Measures of localization performance included: (1 percentage correct localization, (2 percentage of right--left localization errors, (3 percentage of front-rear localization errors, and (4 localization absolute deviation in degrees from the alarm′s actual location. In summary, the data demonstrated that, with some exceptions, normal hearing listeners′ ability to localize the backup alarm in 360-degrees azimuth did not improve when wearing augmented hearing protectors (including dichotic sound transmission earmuffs, flat attenuation earplugs, and level-dependent earplugs as compared to when wearing conventional passive earmuffs or earplugs of the foam or flanged types. Exceptions were that in the 90 dBA pink noise, the flat attenuation earplug yielded significantly better accuracy than the polyurethane foam earplug and both the dichotic and the custom-made diotic electronic sound transmission earmuffs. However, the flat attenuation earplug showed no benefit over the standard pre-molded earplug, the arc earplug, and the passive earmuff. Confusions of front-rear alarm directions were most significant in the 90 dBA noise condition, wherein two types of triple-flanged earplugs exhibited significantly fewer front-rear confusions than either of the electronic muffs. On all measures, the diotic sound transmission earmuff resulted in the poorest localization of any of the protectors due to the fact that its single-microphone design did not enable interaural cues to be heard. Localization was consistently more degraded in the 90 dBA pink noise as compared with the relatively quiet condition of the 60 dBA pink noise. A frequency-augmented backup alarm, which incorporated 400 Hz and 4000 Hz components

  18. [Citalopram, escitalopram and prolonged QT: warning or alarm?].

    Science.gov (United States)

    Alvarez, Enric; Vieira, Sara; Garcia-Moll, Xavier

    2014-01-01

    The alerts issued by regulatory agencies on the potential cardiac toxicity of citalopram and escitalopram have caused alarm among clinicians. A review of the data concerning this topic shows that the alarm should be limited to patients with a history of syncope or poisoning. As a precautionary measure, an electrocardiogram should be performed on elderly patients. Copyright © 2013 SEP y SEPB. Published by Elsevier España. All rights reserved.

  19. Seventh international conference on time-resolved vibrational spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, R.B.; Martinez, M.A.D.; Shreve, A.; Woodruff, W.H. [comps.

    1997-04-01

    The International Conference on Time-Resolved Vibrational Spectroscopy (TRVS) is widely recognized as the major international forum for the discussion of advances in this rapidly growing field. The 1995 conference was the seventh in a series that began at Lake Placid, New York, 1982. Santa Fe, New Mexico, was the site of the Seventh International Conference on Time-Resolved Vibrational Spectroscopy, held from June 11 to 16, 1995. TRVS-7 was attended by 157 participants from 16 countries and 85 institutions, and research ranging across the full breadth of the field of time-resolved vibrational spectroscopy was presented. Advances in both experimental capabilities for time-resolved vibrational measurements and in theoretical descriptions of time-resolved vibrational methods continue to occur, and several sessions of the conference were devoted to discussion of these advances and the associated new directions in TRVS. Continuing the interdisciplinary tradition of the TRVS meetings, applications of time-resolved vibrational methods to problems in physics, biology, materials science, and chemistry comprised a large portion of the papers presented at the conference.

  20. Accident alarm equipment for steam generator, especially liquid sodium heated steam generator

    International Nuclear Information System (INIS)

    Matal, O.; Jung, J.; Banovec, J.

    1982-01-01

    The alarm equipment consists of a system of sensors mounted onto the steam generator and its accessories. Each of the sensors is used for a different accident characteristic, such as the flow of sodium, the acoustic spectrum, the concentration of hydrogen in sodium. The system of sensors is connected to the common accident alarm system. The equipment will not issue the alarm signal if it receives a message from only one sensor, only when the message is confirmed from other sensors. This excludes false alarm. (M.D.)

  1. Noise and vibration analysis system

    International Nuclear Information System (INIS)

    Johnsen, J.R.; Williams, R.L.

    1985-01-01

    The analysis of noise and vibration data from an operating nuclear plant can provide valuable information that can identify and characterize abnormal conditions. Existing plant monitoring equipment, such as loose parts monitoring systems (LPMS) and neutron flux detectors, may be capable of gathering noise data, but may lack the analytical capability to extract useful meanings hidden in the noise. By analyzing neutron noise signals, the structural motion and integrity of core components can be assessed. Computer analysis makes trending of frequency spectra within a fuel cycle and from one cycle to another a practical means of core internals monitoring. The Babcock and Wilcox Noise and Vibration Analysis System (NVAS) is a powerful, compact system that can automatically perform complex data analysis. The system can acquire, process, and store data, then produce report-quality plots of the important parameter. Software to perform neutron noise analysis and loose parts analysis operates on the same hardware package. Since the system is compact, inexpensive, and easy to operate, it allows utilities to perform more frequency analyses without incurring high costs and provides immediate results

  2. Alarm management in TRANSPETRO National Oil Control Center

    Energy Technology Data Exchange (ETDEWEB)

    Amado, Helio; Costa, Luciano [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    For sure Alarm Management is not a new issue. EEMUA 191 has been around since 1999 and everyone has received visits from consultants in this area. Besides this regulators have requested that operators have a policy for it. However there are few papers showing actual pipeline operator experience in alarm management. In this paper we present the work developed in TRANSPETRO National Oil Control Center since 2006, where we operate 5509 km of crude oil and refined products pipelines. Since the beginning of the centralized operation in 2002, alarm management has been a concern but a systematic approach has been taken since 2006. Initially we will make a brief revision of the literature and show trends for regulations. Then we will show the tools and the approach we have taken. Finally, the further developments we see. The point that we want to discuss is that, it has been very difficult to implement the system in a linear way and we believe that companies that have huge legacy systems, the same probably will occur. Putting in simple words, our main conclusion is: Implementing an Alarm Management policy produces good results however probably sometimes is better not to follow strictly the traditional steps. (author)

  3. Flights of fear: a mechanical wing whistle sounds the alarm in a flocking bird.

    Science.gov (United States)

    Hingee, Mae; Magrath, Robert D

    2009-12-07

    Animals often form groups to increase collective vigilance and allow early detection of predators, but this benefit of sociality relies on rapid transfer of information. Among birds, alarm calls are not present in all species, while other proposed mechanisms of information transfer are inefficient. We tested whether wing sounds can encode reliable information on danger. Individuals taking off in alarm fly more quickly or ascend more steeply, so may produce different sounds in alarmed than in routine flight, which then act as reliable cues of alarm, or honest 'index' signals in which a signal's meaning is associated with its method of production. We show that crested pigeons, Ocyphaps lophotes, which have modified flight feathers, produce distinct wing 'whistles' in alarmed flight, and that individuals take off in alarm only after playback of alarmed whistles. Furthermore, amplitude-manipulated playbacks showed that response depends on whistle structure, such as tempo, not simply amplitude. We believe this is the first demonstration that flight noise can send information about alarm, and suggest that take-off noise could provide a cue of alarm in many flocking species, with feather modification evolving specifically to signal alarm in some. Similar reliable cues or index signals could occur in other animals.

  4. Nuisance alarm suppression techniques for fibre-optic intrusion detection systems

    Science.gov (United States)

    Mahmoud, Seedahmed S.; Visagathilagar, Yuvaraja; Katsifolis, Jim

    2012-02-01

    The suppression of nuisance alarms without degrading sensitivity in fibre-optic intrusion detection systems is important for maintaining acceptable performance. Signal processing algorithms that maintain the POD and minimize nuisance alarms are crucial for achieving this. A level crossings algorithm is presented for suppressing torrential rain-induced nuisance alarms in a fibre-optic fence-based perimeter intrusion detection system. Results show that rain-induced nuisance alarms can be suppressed for rainfall rates in excess of 100 mm/hr, and intrusion events can be detected simultaneously during rain periods. The use of a level crossing based detection and novel classification algorithm is also presented demonstrating the suppression of nuisance events and discrimination of nuisance and intrusion events in a buried pipeline fibre-optic intrusion detection system. The sensor employed for both types of systems is a distributed bidirectional fibre-optic Mach Zehnder interferometer.

  5. New Concept For Alarm Structure And Management In Dcs Systems

    Directory of Open Access Journals (Sweden)

    Mohammed Hegazy

    2015-08-01

    Full Text Available The objective of this paper is to set new standard for good design and best practice to applied when any DCS ManufacturesSuppliers configure process alarm system in any oil refining oil and gas production gas-handling facilities gasification plant or any chemical processing plant and thereby to optimizeminimize unnecessary alarms from reporting to operator workstations CAD Control Alarm Display. These views based on the experience acquired and implemented during involvement with the commissioning and startup of two DCS projects in Mina Al-Ahmadi Refinery Kuwait.

  6. Defect Localization Capabilities of a Global Detection Scheme: Spatial Pattern Recognition Using Full-field Vibration Test Data in Plates

    Science.gov (United States)

    Saleeb, A. F.; Prabhu, M.; Arnold, S. M. (Technical Monitor)

    2002-01-01

    Recently, a conceptually simple approach, based on the notion of defect energy in material space has been developed and extensively studied (from the theoretical and computational standpoints). The present study focuses on its evaluation from the viewpoint of damage localization capabilities in case of two-dimensional plates; i.e., spatial pattern recognition on surfaces. To this end, two different experimental modal test results are utilized; i.e., (1) conventional modal testing using (white noise) excitation and accelerometer-type sensors and (2) pattern recognition using Electronic speckle pattern interferometry (ESPI), a full field method capable of analyzing the mechanical vibration of complex structures. Unlike the conventional modal testing technique (using contacting accelerometers), these emerging ESPI technologies operate in a non-contacting mode, can be used even under hazardous conditions with minimal or no presence of noise and can simultaneously provide measurements for both translations and rotations. Results obtained have clearly demonstrated the robustness and versatility of the global NDE scheme developed. The vectorial character of the indices used, which enabled the extraction of distinct patterns for localizing damages proved very useful. In the context of the targeted pattern recognition paradigm, two algorithms were developed for the interrogation of test measurements; i.e., intensity contour maps for the damaged index, and the associated defect energy vector field plots.

  7. The perceived urgency of auditory warning alarms used in the hospital operating room is inappropriate.

    Science.gov (United States)

    Mondor, Todd A; Finley, G Allen

    2003-03-01

    To examine the perceived urgency of 13 auditory warning alarms commonly occurring in the hospital operating room. Undergraduate students, who were naïve with respect to the clinical situation associated with the alarms, judged perceived urgency of each alarm on a ten-point scale. The perceived urgency of the alarms was not consistent with the actual urgency of the clinical situation that triggers it. In addition, those alarms indicating patient condition were generally perceived as less urgent than those alarms indicating the operation of equipment. Of particular interest were three sets of alarms designed by equipment manufacturers to indicate specific priorities for action. Listeners did not perceive any differences in the urgency of the 'information only', 'medium' and 'high' priority alarms of two of the monitors with all judged as low to moderate in urgency. In contrast, the high priority alarm of the third monitor was judged as significantly more urgent than its low and medium urgency counterparts. The alarms currently in use do not convey the intended sense of urgency to naïve listeners, and this holds even for two sets of alarms designed specifically by manufacturers to convey different levels of urgency.

  8. Alarm systems detect volcanic tremor and earthquake swarms during Redoubt eruption, 2009

    Science.gov (United States)

    Thompson, G.; West, M. E.

    2009-12-01

    We ran two alarm algorithms on real-time data from Redoubt volcano during the 2009 crisis. The first algorithm was designed to detect escalations in continuous seismicity (tremor). This is implemented within an application called IceWeb which computes reduced displacement, and produces plots of reduced displacement and spectrograms linked to the Alaska Volcano Observatory internal webpage every 10 minutes. Reduced displacement is a measure of the amplitude of volcanic tremor, and is computed by applying a geometrical spreading correction to a displacement seismogram. When the reduced displacement at multiple stations exceeds pre-defined thresholds and there has been a factor of 3 increase in reduced displacement over the previous hour, a tremor alarm is declared. The second algorithm was to designed to detect earthquake swarms. The mean and median event rates are computed every 5 minutes based on the last hour of data from a real-time event catalog. By comparing these with thresholds, three swarm alarm conditions can be declared: a new swarm, an escalation in a swarm, and the end of a swarm. The end of swarm alarm is important as it may mark a transition from swarm to continuous tremor. Alarms from both systems were dispatched using a generic alarm management system which implements a call-down list, allowing observatory scientists to be called in sequence until someone acknowledged the alarm via a confirmation web page. The results of this simple approach are encouraging. The tremor alarm algorithm detected 26 of the 27 explosive eruptions that occurred from 23 March - 4 April. The swarm alarm algorithm detected all five of the main volcanic earthquake swarm episodes which occurred during the Redoubt crisis on 26-27 February, 21-23 March, 26 March, 2-4 April and 3-7 May. The end-of-swarm alarms on 23 March and 4 April were particularly helpful as they were caused by transitions from swarm to tremor shortly preceding explosive eruptions; transitions which were

  9. The development of NSSS digital integrity monitoring system

    International Nuclear Information System (INIS)

    Ham, Chang Shik; Kim, Jung Soo; Jung, Chul Hwan; Hwang, In Koo; Kim, Tak Hwane; Kim, Tae Hwane; Park, Jin Ho; Kyung, Sung Yoon; Hyeon, Ryu Kye; Seong, Joo Hyun; Kim, Georn Myung; Eun, Sung Hun; Kwack, Jin Gu; Park, Joon Hee

    1999-11-01

    The primary function of loose part monitoring system (LPMS) is to detect the occurrence of any loose part in the primary coolant system caused by being parted or loosened from the mechanical structure during normal operation and refueling times. The existing LPMSs generates an alarm when the detected signal from the accelerometer sensors attached to the surface of the primary pressure boundary was bigger than the alarm threshold value. The internal vibration monitoring system (IVMS) senses a change of vibration of the reactor vessel internal structure using the ex-core neutron signals. The vibrations of internal mechanical structure are caused by the high velocity flow of the pressurized primary coolant. If the flow-induced vibration forces to loosen the internal components supporting the fuel assembly, the safety of nuclear reactor will be affected. The IVMS provides the information of abnormality in the vibration pattern and amplitude for plant operators to take proper actions against the abnormal condition for nuclear power plants (NPPs). An advanced LPMS should be capable to identify the physical characteristics of the potential loose part from the detected signal. Those improved diagnostic function will be the capabilities to analyze the detected signal and to estimate the expected impact position and mass automatically. The technologies and methods of estimation for impact mass and position as well as a new modeling method of reactor internal vibration modes were developed and provided to Woojin Co. from Korea Energy Research Institute (KAERI). Based on the transferred technologies, Woojin Co. has designed the hardware system of LPMS and IVMS. Some of the hardware components were integrated and the hardware-oriented software modules were also developed and designed. (author)

  10. Communication strategies and timeliness of response to life critical telemetry alarms.

    Science.gov (United States)

    Bonzheim, Kimberly A; Gebara, Rani I; O'Hare, Bridget M; Ellis, R Darin; Brand, Monique A; Balar, Salil D; Stockman, Rita; Sciberras, Annette M; Haines, David E

    2011-05-01

    A centralized electrocardiogram telemetry monitoring system (TMS) facilitates early identification of critical arrhythmias and acute medical decompensation. Timely intervention can only be performed if abnormalities are communicated rapidly to the direct caregiver. The study objectives were to measure effectiveness of bi-directional voice communication badges versus one-way alphanumeric pagers for telemetry alarm response and communication loop closure. A sequential observational pilot study of nursing response to TMS alarms compared communication technologies on four nursing units in a 1,061 bed tertiary care hospital with 264 TMS channels of telemetry over a 2-year period. Subsequently, the communication technologies were compared in a randomized fashion on a 68-bed progressive cardiac care unit. Caregivers were blinded to the protocol. All alarm responses were recorded during two periods using either pagers or voice communication devices. Alarm response time and closure of the communication loop were analyzed in a blinded fashion. The direct communication functionality of the badge significantly shortened the time to first contact, time to completion, and rate of closure of the communication loop in both the pilot and study phases. Median time to first contact with the communication badge was 0.5  min, compared to 1.6  min with pager communication (p Communication loop closure was achieved in 100% of clinical alarms using the badge versus 19% with the pager (p Communication badge technology reduced alarm time to first contact and completion as well as facilitated communication loop closures. Immediate two-way communication significantly impacted practice, alarm management, and resulted in faster bedside care.

  11. Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

    Science.gov (United States)

    Hunter, Gary W.; Greensburg, Paul; McKnight, Robert; Xu, Jennifer C.; Liu, C. C.; Dutta, Prabir; Makel, Darby; Blake, D.; Sue-Antillio, Jill

    2007-01-01

    Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can

  12. Measurement of the Portsmouth Gaseous Diffusion Plant criticality accident alarm

    International Nuclear Information System (INIS)

    Tayloe, R.W. Jr.; McGinnis, B.

    1990-01-01

    Measurements of the Portsmouth Gaseous Diffusion Plant's nuclear criticality accident radiation alarm signal response time, sound wave frequency, and sound volume levels were made to demonstrate compliance with ANSI/ANS-8.3-1986. A steady-state alarm signal is produced within one-half second of obtaining a two-out-of-three detector trip. The fundamental alarm sound wave frequency is 440 hertz. The sound volume levels are greater than 10 decibels above background and ranged from 100 to 125 A-weighted decibels. The requirements of the standard were met; however the recommended maximum sound volume level of 115 dBA was exceeded. Emergency procedures require immediate evacuation upon initiation of a facility's radiation alarm. Comparison with standards for allowable time of exposure at different noise levels indicate that the elevated noise level at this location does not represent an occupational injury hazard. 8 refs., 5 figs

  13. Induced vibrations increase performance of a winged self-righting robot

    Science.gov (United States)

    Othayoth, Ratan; Xuan, Qihan; Li, Chen

    When upside down, cockroaches can open their wings to dynamically self-right. In this process, an animal often has to perform multiple unsuccessful maneuvers to eventually right, and often flails its legs. Here, we developed a cockroach-inspired winged self-righting robot capable of controlled body vibrations to test the hypothesis that vibrations assist self-righting transitions. Robot body vibrations were induced by an oscillating mass (10% of body mass) and varied by changing oscillation frequency. We discovered that, as the robot's body vibrations increased, righting probability increased, and righting time decreased (P locomotor transitions, but highlights the need for further stochastic modeling to capture the uncertain nature of when righting maneuvers result in successful righting.

  14. Vibration-based Energy Harvesting Systems Characterization Using Automated Electronic Equipment

    Directory of Open Access Journals (Sweden)

    Ioannis KOSMADAKIS

    2015-04-01

    Full Text Available A measurement bench has been developed to fully automate the procedure for the characterization of a vibration-based energy scavenging system. The measurement system is capable of monitoring all important characteristics of a vibration harvesting system (input and output voltage, current, and other parameters, frequency and acceleration values, etc.. It is composed of a PC, typical digital measuring instruments (oscilloscope, waveform generator, etc., certain sensors and actuators, along with a microcontroller based automation module. The automation of the procedure and the manipulation of the acquired data are performed by LabVIEW software. Typical measurements of a system consisting of a vibrating source, a vibration transducer and an active rectifier are presented.

  15. Definition and means of maintaining the criticality detectors and alarms portion of the PFP safety envelope

    International Nuclear Information System (INIS)

    White, W.F.

    1997-01-01

    The Criticality Alarm System (CAS) provides continuous detection for high radiation (criticality) events and automatically initiates an evacuation signal to affected personnel. The Safety Envelope (SE) for PFP includes the necessary equipment and the required procedures to ensure the CAS is capable of performing its intended function. This document provides the definition and means of maintaining the SE for PFP related to the CAS. This document also identifies and provides a justification for those portions of the CAS excluded from the PFP Safety Envelope

  16. The alarm system of the SAPHIR detector

    International Nuclear Information System (INIS)

    Schultz-Coulon, H.C.

    1993-06-01

    In order to obtain an effective control of the different detector components an alarm system was built and implemented into the data acquisition system of the SAPHIR experiment. It provides an easy way of indicating errors by either adequate library calls or an appropriate hardware signal, both leading to an active alarm. This allows to react directly to any error detected by one of the specific control systems. In addition for selected kinds of errors the data run can be stopped automatically. Concept and construction of this system are described and some examples for its application are given. (orig.)

  17. Automated Information System (AIS) Alarm System

    International Nuclear Information System (INIS)

    Hunteman, W.

    1997-01-01

    The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, the assessment criteria, and the desired responses may be set by the using organization to meet their local security policies

  18. Automated Information System (AIS) Alarm System

    Energy Technology Data Exchange (ETDEWEB)

    Hunteman, W.

    1997-05-01

    The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, the assessment criteria, and the desired responses may be set by the using organization to meet their local security policies.

  19. PREFACE: Vibrations at surfaces Vibrations at surfaces

    Science.gov (United States)

    Rahman, Talat S.

    2011-12-01

    This special issue is dedicated to the phenomenon of vibrations at surfaces—a topic that was indispensible a couple of decades ago, since it was one of the few phenomena capable of revealing the nature of binding at solid surfaces. For clean surfaces, the frequencies of modes with characteristic displacement patterns revealed how surface geometry, as well as the nature of binding between atoms in the surface layers, could be different from that in the bulk solid. Dispersion of the surface phonons provided further measures of interatomic interactions. For chemisorbed molecules on surfaces, frequencies and dispersion of the vibrational modes were also critical for determining adsorption sites. In other words, vibrations at surfaces served as a reliable means of extracting information about surface structure, chemisorption and overlayer formation. Experimental techniques, such as electron energy loss spectroscopy and helium-atom-surface scattering, coupled with infra-red spectroscopy, were continually refined and their resolutions enhanced to capture subtleties in the dynamics of atoms and molecules at surfaces. Theoretical methods, whether based on empirical and semi-empirical interatomic potential or on ab initio electronic structure calculations, helped decipher experimental observations and provide deeper insights into the nature of the bond between atoms and molecules in regions of reduced symmetry, as encountered on solid surfaces. Vibrations at surfaces were thus an integral part of the set of phenomena that characterized surface science. Dedicated workshops and conferences were held to explore the variety of interesting and puzzling features revealed in experimental and theoretical investigations of surface vibrational modes and their dispersion. One such conference, Vibrations at Surfaces, first organized by Harald Ibach in Juelich in 1980, continues to this day. The 13th International Conference on Vibrations at Surfaces was held at the University of

  20. 40 CFR 264.34 - Access to communications or alarm system.

    Science.gov (United States)

    2010-07-01

    ... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a) Whenever... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Access to communications or alarm system. 264.34 Section 264.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...

  1. 40 CFR 265.34 - Access to communications or alarm system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Access to communications or alarm system. 265.34 Section 265.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID..., STORAGE, AND DISPOSAL FACILITIES Preparedness and Prevention § 265.34 Access to communications or alarm...

  2. Vibration control for precision manufacturing at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Hinnerichs, T.; Martinez, D.

    1995-01-01

    Sandia National Laboratories performs R and D in structural dynamics and vibration suppression for precision applications in weapon systems, space, underwater, transportation and civil structures. Over the last decade these efforts have expanded into the areas of active vibration control and ''smart'' structures and material systems. In addition, Sandia has focused major resources towards technology to support weapon product development and agile manufacturing capability for defense and industrial applications. This paper will briefly describe the structural dynamics modeling and verification process currently in place at Sandia that supports vibration control and some specific applications of these techniques to manufacturing in the areas of lithography, machine tools and flexible robotics

  3. Vibration control for precision manufacturing at Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Hinnerichs, T.; Martinez, D. [Sandia National Labs., Albuquerque, NM (United States). Structural Dynamics and Vibration Control Dept.

    1995-04-01

    Sandia National Laboratories performs R and D in structural dynamics and vibration suppression for precision applications in weapon systems, space, underwater, transportation and civil structures. Over the last decade these efforts have expanded into the areas of active vibration control and ``smart`` structures and material systems. In addition, Sandia has focused major resources towards technology to support weapon product development and agile manufacturing capability for defense and industrial applications. This paper will briefly describe the structural dynamics modeling and verification process currently in place at Sandia that supports vibration control and some specific applications of these techniques to manufacturing in the areas of lithography, machine tools and flexible robotics.

  4. Elliptical Leaf Spring Shock and Vibration Mounts with Enhanced Damping and Energy Dissipation Capabilities Using Lead Spring

    Directory of Open Access Journals (Sweden)

    Moussa Leblouba

    2015-01-01

    Full Text Available We present an enhancement to the existing elliptical leaf spring (ELS for improved damping and energy dissipation capabilities. The ELS consists of a high tensile stainless steel elliptical leaf spring with polymer or rubber compound. This device is conceived as a shock and vibration isolator for equipment and lightweight structures. The enhancement to the ELS consists of a lead spring plugged vertically between the leaves (referred to as lead-rubber elliptical leaf spring (LRELS. The lead is shown to produce hysteretic damping under plastic deformations. The LRELS isolator is shown to exhibit nonlinear hysteretic behavior. In both horizontal directions, the LRELS showed symmetrical rate independent behavior but undergoes stiffening behavior under large displacements. However, in the vertical direction, the LRELS behavior is asymmetric, exhibiting softening behavior in compression and stiffening behavior in tension. Mathematical models based on the Bouc-Wen model, describing the hysteretic behavior of the proposed isolator, are developed and numerically calibrated using a series of finite element analyses. The LRELS is found to be effective in the in-plane and vertical directions. The improved damping and energy dissipation of the LRELS is provided from the hysteretic damping of the lead spring.

  5. A new diagnosis method using alarm annunciation for FBR power plants

    International Nuclear Information System (INIS)

    Ozaki, Y.; Suda, K.; Yoshikawa, S.; Ozawa, K.

    1997-01-01

    We discuss the methodology diversity for diagnosis reasoning in autonomous operation system, and propose a new diagnosis method using alarm annunciation system. The methodology diversity is assured by preparing plural agents, each of which is based on its own different methodology, therefore, it is expected for the reliability in diagnosis to be improved. Meanwhile, the combination of annunciated alarms is expected to be peculiar to the anomalous phenomenon or accident. Moreover, as the state of affairs is developing, each appearance of the pattern is changing with time peculiarly to each anomaly or accident. The matter is utilized for the new diagnosis method. The patterns of annunciated alarms with progress of the events are prepared in advance under the condition of the anomalies or accidents by use of plant simulatory. The diagnostic reasoning can be done by comparing the obtained combination of annunciated alarms with the reference templates, pattern matching method. On the other hand, we have another method, called as COBWEB used for conceptual classification in cognitive science, to reason for diagnosis. We have carried out the experiments using the loop type LMFBR plant simulator to obtain the various combinations of annunciated alarms with progress of the events under the conditions of anomalies and accidents. The examined cases were related to the anomalies and accidents in the water/steam system of the LMFBR power plant. We have obtained the conclusions that it is effective to reason the causes of anomalies using the annunciated alarms. We are going to apply the pattern matching technique or COBWEB method into the diagnostic reasoning to confirm the performance of the proposed diagnosis method based on the alarm annunciation. (author). 5 refs, 14 figs

  6. Wild birds learn to eavesdrop on heterospecific alarm calls.

    Science.gov (United States)

    Magrath, Robert D; Haff, Tonya M; McLachlan, Jessica R; Igic, Branislav

    2015-08-03

    Many vertebrates gain critical information about danger by eavesdropping on other species' alarm calls [1], providing an excellent context in which to study information flow among species in animal communities [2-4]. A fundamental but unresolved question is how individuals recognize other species' alarm calls. Although individuals respond to heterospecific calls that are acoustically similar to their own, alarms vary greatly among species, and eavesdropping probably also requires learning [1]. Surprisingly, however, we lack studies demonstrating such learning. Here, we show experimentally that individual wild superb fairy-wrens, Malurus cyaneus, can learn to recognize previously unfamiliar alarm calls. We trained individuals by broadcasting unfamiliar sounds while simultaneously presenting gliding predatory birds. Fairy-wrens in the experiment originally ignored these sounds, but most fled in response to the sounds after two days' training. The learned response was not due to increased responsiveness in general or to sensitization following repeated exposure and was independent of sound structure. Learning can therefore help explain the taxonomic diversity of eavesdropping and the refining of behavior to suit the local community. In combination with previous work on unfamiliar predator recognition (e.g., [5]), our results imply rapid spread of anti-predator behavior within wild populations and suggest methods for training captive-bred animals before release into the wild [6]. A remaining challenge is to assess the importance and consequences of direct association of unfamiliar sounds with predators, compared with social learning-such as associating unfamiliar sounds with conspecific alarms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. A novel fiber-optical vibration defending system with on-line intelligent identification function

    Science.gov (United States)

    Wu, Huijuan; Xie, Xin; Li, Hanyu; Li, Xiaoyu; Wu, Yu; Gong, Yuan; Rao, Yunjiang

    2013-09-01

    Capacity of the sensor network is always a bottleneck problem for the novel FBG-based quasi-distributed fiberoptical defending system. In this paper, a highly sensitive sensing network with FBG vibration sensors is presented to relieve stress of the capacity and the system cost. However, higher sensitivity may cause higher Nuisance Alarm Rates (NARs) in practical uses. It is necessary to further classify the intrusion pattern or threat level and determine the validity of an unexpected event. Then an intelligent identification method is proposed by extracting the statistical features of the vibration signals in the time domain, and inputting them into a 3-layer Back-Propagation(BP) Artificial Neural Network to classify the events of interest. Experiments of both simulation and field tests are carried out to validate its effectiveness. The results show the recognition rate can be achieved up to 100% for the simulation signals and as high as 96.03% in the real tests.

  8. Intrusion recognition for optic fiber vibration sensor based on the selective attention mechanism

    Science.gov (United States)

    Xu, Haiyan; Xie, Yingjuan; Li, Min; Zhang, Zhuo; Zhang, Xuewu

    2017-11-01

    Distributed fiber-optic vibration sensors receive extensive investigation and play a significant role in the sensor panorama. A fiber optic perimeter detection system based on all-fiber interferometric sensor is proposed, through the back-end analysis, processing and intelligent identification, which can distinguish effects of different intrusion activities. In this paper, an intrusion recognition based on the auditory selective attention mechanism is proposed. Firstly, considering the time-frequency of vibration, the spectrogram is calculated. Secondly, imitating the selective attention mechanism, the color, direction and brightness map of the spectrogram is computed. Based on these maps, the feature matrix is formed after normalization. The system could recognize the intrusion activities occurred along the perimeter sensors. Experiment results show that the proposed method for the perimeter is able to differentiate intrusion signals from ambient noises. What's more, the recognition rate of the system is improved while deduced the false alarm rate, the approach is proved by large practical experiment and project.

  9. Internal Temperature Control For Vibration Testers

    Science.gov (United States)

    Dean, Richard J.

    1996-01-01

    Vibration test fixtures with internal thermal-transfer capabilities developed. Made of aluminum for rapid thermal transfer. Small size gives rapid response to changing temperatures, with better thermal control. Setup quicker and internal ducting facilitates access to parts being tested. In addition, internal flows smaller, so less energy consumed in maintaining desired temperature settings.

  10. Advanced alarm system design and human performance: Guidance development and current research

    Energy Technology Data Exchange (ETDEWEB)

    O` Hara, J M [Brookhaven National Lab., Upton, NY (United States)

    1997-09-01

    This paper describes a research program sponsored by the U.S. Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. Guidance has been developed based on a broad base of technical and research literature. As part of the development effort, aspects of alarm system design for which the technical basis was insufficient to support guidance development were identified and prioritized. Research is currently underway to address the highest priority topics: alarm processing and display characteristics. (author). 29 refs, 2 figs.

  11. Advanced alarm system design and human performance: Guidance development and current research

    International Nuclear Information System (INIS)

    O'Hara, J.M.

    1997-01-01

    This paper describes a research program sponsored by the U.S. Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. Guidance has been developed based on a broad base of technical and research literature. As part of the development effort, aspects of alarm system design for which the technical basis was insufficient to support guidance development were identified and prioritized. Research is currently underway to address the highest priority topics: alarm processing and display characteristics. (author). 29 refs, 2 figs

  12. Integrated active sensor system for real time vibration monitoring.

    Science.gov (United States)

    Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue

    2015-11-05

    We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0-60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems.

  13. Digital data acquisition for laser radar for vibration analysis

    OpenAIRE

    Montes, Felix G.

    1998-01-01

    Approved for public release; distribution is unlimited Laser radar for vibration analysis represents a military application to develop a target identification system in the future. The problem addressed is how to analyze the vibrations of a target illuminated by the laser radar to achieve a positive identification. This thesis develops a computer-based data acquisition and analysis system for improving the laser radar capability. Specifically, a review is made of the CO2 laser radar, coher...

  14. Alarm pheromone does not modulate 22-kHz calls in male rats.

    Science.gov (United States)

    Muyama, Hiromi; Kiyokawa, Yasushi; Inagaki, Hideaki; Takeuchi, Yukari; Mori, Yuji

    2016-03-15

    Rats are known to emit a series of ultrasonic vocalizations, termed 22-kHz calls, when exposed to distressing stimuli. Pharmacological studies have indicated that anxiety mediates 22-kHz calls in distressed rats. We previously found that exposure to the rat alarm pheromone increases anxiety in rats. Therefore, we hypothesized that the alarm pheromone would increase 22-kHz calls in pheromone-exposed rats. Accordingly, we tested whether exposure to the alarm pheromone induced 22-kHz calls, as well as whether the alarm pheromone increased 22-kHz calls in response to an aversive conditioned stimulus (CS). Rats were first fear-conditioned to an auditory and contextual CS. On the following day, the rats were either exposed to the alarm pheromone or a control odor that was released from the neck region of odor-donor rats. Then, the rats were re-exposed to the aversive CS. The alarm pheromone neither induced 22-kHz calls nor increased 22-kHz calls in response to the aversive CS. In contrast, the control odor unexpectedly reduced the total number and duration of 22-kHz calls elicited by the aversive CS, as well as the duration of freezing. These results suggest that the alarm pheromone does not affect 22-kHz calls in rats. However, we may have found evidence for an appeasing olfactory signal, released from the neck region of odor-donor rats. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Development of alarm logics for critical function monitoring in SMART-P reactor

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Seung Hwan; Hur, Seop; Seo, Jae Kwang; Lee, Tae Ho; Park, Cheon Tae; Kang, Han Ok

    2003-04-01

    The alarm logics for the critical functions of SMART-P reactor are developed, which are based on the those of Korean Standard Nuclear power Plant(KSNP). The SMART-P reactor is an integral typed nuclear power plant and has the some different design features compared to those of KSNP. It, however, has the similar features in critical functions because it is a kind of pressurized water reactor. The alarm logics for Critical Function Monitoring System(CFMS) in SMART-P are developed from those for CFMS in KSNP. The alarm logics of CFMS in only the primary loop are, therefore, developed, though the general CFMS covered the status of primary and secondary loop including the features of the containment. The specific setpoint of related variables related to the alarm logics will be developed after the specific designs of SMART-P are finished. In appendix, we describe the conceptual architecture and variables of display screens on CFMS according to the developed alarm logics.

  16. Leak detection capability in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Azer, N.; Barber, D.H.; Boucher, P.J. [and others

    1997-04-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.

  17. Leak detection capability in CANDU reactors

    International Nuclear Information System (INIS)

    Azer, N.; Barber, D.H.; Boucher, P.J.

    1997-01-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis

  18. Fixed Base Modal Testing Using the NASA GRC Mechanical Vibration Facility

    Science.gov (United States)

    Staab, Lucas D.; Winkel, James P.; Suarez, Vicente J.; Jones, Trevor M.; Napolitano, Kevin L.

    2016-01-01

    The Space Power Facility at NASA's Plum Brook Station houses the world's largest and most powerful space environment simulation facilities, including the Mechanical Vibration Facility (MVF), which offers the world's highest-capacity multi-axis spacecraft shaker system. The MVF was designed to perform sine vibration testing of a Crew Exploration Vehicle (CEV)-class spacecraft with a total mass of 75,000 pounds, center of gravity (cg) height above the table of 284 inches, diameter of 18 feet, and capability of 1.25 gravity units peak acceleration in the vertical and 1.0 gravity units peak acceleration in the lateral directions. The MVF is a six-degree-of-freedom, servo-hydraulic, sinusoidal base-shake vibration system that has the advantage of being able to perform single-axis sine vibration testing of large structures in the vertical and two lateral axes without the need to reconfigure the test article for each axis. This paper discusses efforts to extend the MVF's capabilities so that it can also be used to determine fixed base modes of its test article without the need for an expensive test-correlated facility simulation.

  19. Alarm symptoms of upper gastrointestinal cancer and contact to general practice

    DEFF Research Database (Denmark)

    Rasmussen, Sanne; Larsen, Pia Veldt; Svendsen, Rikke Pilsgaard

    2015-01-01

    INTRODUCTION: Survival of upper gastrointestinal (GI) cancer depends on early stage diagnosis. Symptom-based guidelines and fast-track referral systems have been implemented for use in general practice. To improve diagnosis of upper GI cancer, knowledge on prevalence of alarm symptoms...... between 1.1% ("repeated vomiting") and 3.4% ("difficulty swallowing"). Women had higher odds of experiencing "repeated vomiting" and "persistent and recent-onset abdominal pain", but lower odds of experiencing "upper GI bleeding". The proportion of people contacting their GP with each of the four specific...... alarm symptoms ranged from 24.3% ("upper GI bleeding") to 39.9% ("repeated vomiting"). For each combination of two specific alarm symptoms, at least 52% contacted their GP. CONCLUSION: The specific alarm symptoms of upper GI cancer are not very prevalent in the general population. The proportion of GP...

  20. Development of alarm cause tracking system for Korea standard nuclear power plant

    International Nuclear Information System (INIS)

    Lee, Jung Woon; Kim, Jung Taek; Park, Jae Chang; Lee, Hyun Chul; Park, Joong Pal

    2004-05-01

    The proposed system, the ACTS(Alarm Cause Tracking System), in the 1st and 2nd development period(2001. 7 ∼ 2003. 6), tracks and displays the causes of alarms on-line from computerized logic diagrams. And the system highlights the specific procedures related the causes in the procedure of the alarm. In this period(2003. 7 ∼ 2004. 4), we developed the ACTS for Korea standard nuclear power plant. Also, we computerized control logic diagrams and alarm procedures for the ACTS. A long-term target is to apply the ACTS at the real power plant, and a short-term target is to connect the ACTS with the ITF(Intergrated Test Facility) in KAERI site to develop other applications

  1. Multi-parameter vital sign database to assist in alarm optimization for general care units.

    Science.gov (United States)

    Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs

    2016-12-01

    Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO 2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

  2. The effectiveness of nurse education and training for clinical alarm response and management: a systematic review.

    Science.gov (United States)

    Yue, Liqing; Plummer, Virginia; Cross, Wendy

    2017-09-01

    To identify the effectiveness of education interventions provided for nurses for clinical alarm response and management. Some education has been undertaken to improve clinical alarm response, but the evidence for evaluating effectiveness for nurse education interventions is limited. Systematic review. A systematic review of experimental studies published in English from 2005-2015 was conducted in four computerised databases (MEDLINE, EMBASE, CINAHL and Scopus). After identification, screening and appraisal using Joanna Briggs Institute instruments, quality research papers were selected, data extraction and analysis followed. Five studies met the inclusion criteria for alarm response and no articles were concerned with clinical alarm education for management. All had different types and methods of interventions and statistical pooling was not possible. Response accuracy, response time and perceptions were consistent when different interventions were adopted. A positive effect was identified when learning about general alarms, single alarms, sequential alarms and medium-level alarms for learning as the primary task. Nurses who were musically trained had a faster and more accurate alarm response. Simulation interventions had a positive effect, but the effect of education provided in the care unit was greater. Overall, clinical alarm awareness was improved through education activities. Nurses are the main users of healthcare alarms and work in complex environments with high numbers of alarms, including nuisance alarms and other factors. Alarm-related adverse events are common. The findings of a small number of experimental studies with diverse evidence included consideration of various factors when formulating education strategies. The factors which influence effectiveness of nurse education are nurse demographics, nurse participants with musical training, workload and characteristics of alarms. Education interventions based in clinical practice settings increase

  3. Teaching methodology of the diagnosing process on the example of the fire alarm system

    Directory of Open Access Journals (Sweden)

    Paś Jacek

    2017-03-01

    Full Text Available The article presents a method of teaching the process of diagnosing the technical and functional condition of the fire alarm system (SSP. The fire alarm system’s laboratory model is a representation of a real fire alarm system. The lecturer has the opportunity to inflict several different independent damage. The aim of the laboratory exercise is to familiarize students with the methodology and structure of the fire alarm system diagnosing process.

  4. Strain and Vibration in Mesenchymal Stem Cells

    Directory of Open Access Journals (Sweden)

    Brooke McClarren

    2018-01-01

    Full Text Available Mesenchymal stem cells (MSCs are multipotent cells capable of differentiating into any mesenchymal tissue, including bone, cartilage, muscle, and fat. MSC differentiation can be influenced by a variety of stimuli, including environmental and mechanical stimulation, scaffold physical properties, or applied loads. Numerous studies have evaluated the effects of vibration or cyclic tensile strain on MSCs towards developing a mechanically based method of differentiation, but there is no consensus between studies and each investigation uses different culture conditions, which also influence MSC fate. Here we present an overview of the response of MSCs to vibration and cyclic tension, focusing on the effect of various culture conditions and strain or vibration parameters. Our review reveals that scaffold type (e.g., natural versus synthetic; 2D versus 3D can influence cell response to vibration and strain to the same degree as loading parameters. Hence, in the efforts to use mechanical loading as a reliable method to differentiate cells, scaffold selection is as important as method of loading.

  5. Automatically Identifying and Predicting Unplanned Wind Turbine Stoppages Using SCADA and Alarms System Data: Case Study and Results

    Science.gov (United States)

    Leahy, Kevin; Gallagher, Colm; Bruton, Ken; O'Donovan, Peter; O'Sullivan, Dominic T. J.

    2017-11-01

    Using 10-minute wind turbine SCADA data for fault prediction offers an attractive way of gaining additional prognostic capabilities without needing to invest in extra hardware. To use these data-driven methods effectively, the historical SCADA data must be labelled with the periods when the turbine was in faulty operation as well the sub-system the fault was attributed to. Manually identifying faults using maintenance logs can be effective, but is also highly time consuming and tedious due to the disparate nature of these logs across manufacturers, operators and even individual maintenance events. Turbine alarm systems can help to identify these periods, but the sheer volume of alarms and false positives generated makes analysing them on an individual basis ineffective. In this work, we present a new method for automatically identifying historical stoppages on the turbine using SCADA and alarms data. Each stoppage is associated with either a fault in one of the turbine’s sub-systems, a routine maintenance activity, a grid-related event or a number of other categories. This is then checked against maintenance logs for accuracy and the labelled data fed into a classifier for predicting when these stoppages will occur. Results show that the automated labelling process correctly identifies each type of stoppage, and can be effectively used for SCADA-based prediction of turbine faults.

  6. Resolving MC and A alarms from process monitoring in a fuel fabrication facility

    International Nuclear Information System (INIS)

    Smith, B.W.; Razvi, J.

    1984-01-01

    Process monitoring data can be used for generating material loss estimates. The intent of using process control data is to enhance nuclear material control and accounting for the timely detection and resolution of discrepancies. The purpose of an alarm resolution system is to distinguish between system errors and an actual loss of nuclear material. A study has been performed to develop and test a site-specific set of alarm resolution procedures. The results of the study are described and include the frequency of alarms, the causes of alarms, the type of resolution, and the modeling of loss estimates

  7. A Human Factors Perspective on Alarm System Research and Development 2000 to 2010

    Energy Technology Data Exchange (ETDEWEB)

    Curt Braun; John Grimes; Eric Shaver; Ronald Boring (Principal Investigator)

    2011-09-01

    By definition, alarms serve to notify human operators of out-of-parameter conditions that could threaten equipment, the environment, product quality and, of course, human life. Given the complexities of industrial systems, human machine interfaces, and the human operator, the understanding of how alarms and humans can best work together to prevent disaster is continually developing. This review examines advances in alarm research and development from 2000 to 2010 and includes the writings of trade professionals, engineering and human factors researchers, and standards organizations with the goal of documenting advances in alarms system design, research, and implementation.

  8. [Alarm symptoms of meningitis in children with fever].

    Science.gov (United States)

    Geurts, Dorien H F; Moll, Henriette A

    2011-01-01

    A 15-year-old girl presented with fever and pain in her legs. A viral infection was suspected, but within 24 hours she became confused and developed meningeal signs, based on which she was diagnosed as having meningitis. Within a few hours a 6-month-old boy developed fever, a grey colour, bulging fontanel, cold hands and feet, and was groaning. He too appeared to have meningitis. It is important to recognize this serious infection in children with fever, since delay of diagnosis and treatment may result in serious complications. Recognition is difficult because of non-specific symptoms on presentation and a lack of alarm symptoms early in the course of the disease. Alarm symptoms of serious infection in children are cyanosis, rapid breathing, decreased capillary refill, petechial rash, meningeal signs, leg pain and decreased consciousness. If serious infection is uncertain in a child with fever, parents should be advised on the potential course of the disease, the alarm symptoms and the need to seek medical help in time.

  9. Identification and Isolation of Human Alarm Pheromones

    National Research Council Canada - National Science Library

    Mujica-Parodi, Lilianne R; Strey, Helmut

    2006-01-01

    .... Task I, Optimization of Sample Collection, focused on the collection of the putative alarm pheromone via axillary sweat samples obtained during reference (physical exercise) and arousal (skydive) conditions...

  10. Alarm personal dosemeter

    International Nuclear Information System (INIS)

    Nunomiya, Tomoya; Yamauchi, Hideshi; Shibata, Tetsuo

    2007-01-01

    Fuji Electric advanced the development of the conventional alarm personal dosemeter (APD) by adopting JIS Z 4312 (2002), which reflects IEC61526 (1998), and by improving the radiation performance characteristics, electromagnetic performance characteristics and mechanical performance characteristics of the APD (acquiring a CE marking). This new dosemeter will target overseas market in the future. The APD is a suitable dosemeter for detecting and monitoring radiation exposure to personnel working in the controlled areas of nuclear facilities, such as nuclear power stations. The APD product line includes 'gamma ray', 'gamma ray + beta ray' and 'gamma ray + neutron' models. (author)

  11. Seismic alarm system for Ignalina nuclear power plant

    International Nuclear Information System (INIS)

    Wieland, M.; Griesser, L.; Austin, G.E.; Tiurin, S.; Kuendig, C.

    2001-01-01

    A seismic alarm system will be installed at the Ignalina Nuclear Power Plant (INPP) in Lithuania. There are two reactors, both RMBK 1500 MW units. Each reactor is a water cooled, graphite moderated, channel type reactor. INPP has the most advanced version of the RMBK reactor design series. The first and second units of INPP went into service at the end of 1983 and in August 1987 respectively. Their design lifetime is approx. 30 years. The various buildings and plant have been designed for two earthquake levels, that is the design earthquake and the maximum possible earthquake with peak ground accelerations ranging from 1.2% to 10% of the acceleration due to gravity. Certain parts of the buildings and some of the equipment of the first and second units do not comply with Western seismic standards. As seismic strengthening of the existing buildings and equipment is not feasible economically, a reactor protection system based on an earthquake early warning system was recommended. This system essentially consists of six seismic stations encircling INPP at a radial distance of approx. 30 km and a seventh station at INPP. Each station includes three seismic substations each 500 m apart. The ground motion at each station is measured continuously by three accelerometers and one seismometer. Data is transmitted via telemetry to the control centre at INPP. Early warning alarms are generated if a seismic threshold is exceeded. This paper discusses the characteristics of INPP, the seismic alarm system presently under construction and the experience with other early warning and seismic alarm systems. (author)

  12. Wireless alerting system using vibration for vehicles dashboard

    Science.gov (United States)

    Raj, Sweta; Rai, Shweta; Magaramagara, Wilbert; Sivacoumar, R.

    2017-11-01

    This paper aims at improving the engine life of any vehicle through a continuous measurement and monitoring of vital engine operational parameters and providing an effective alerting to drivers for any abnormality. Vehicles currently are using audio and visible alerting signals through alarms and light as a warning to the driver but these are not effective in noisy environments and during daylight. Through the use of the sense of feeling a driver can be alerted effectively. The need to no other vehicle parameter needs to be aided through the mobile display (phone).Thus a system is designed and implements to measure engine temperature, RPM, Oil level and Coolant level using appropriate sensors and a wireless communication (Bluetooth) is established to actuate a portable vibration control device and to read the different vehicle sensor readings through an android application for display and diagnosis.

  13. A vibration powered wireless mote on the Forth Road Bridge

    International Nuclear Information System (INIS)

    Jia, Yu; Yan, Jize; Feng, Tao; Du, Sijun; Fidler, Paul; Soga, Kenichi; Middleton, Campbell; Seshia, Ashwin A

    2015-01-01

    The conventional resonant-approaches to scavenge kinetic energy are typically confined to narrow and single-band frequencies. The vibration energy harvester device reported here combines both direct resonance and parametric resonance in order to enhance the power responsiveness towards more efficient harnessing of real-world ambient vibration. A packaged electromagnetic harvester designed to operate in both of these resonant regimes was tested in situ on the Forth Road Bridge. In the field-site, the harvester, with an operational volume of ∼126 cm 3 , was capable of recovering in excess of 1 mW average raw AC power from the traffic-induced vibrations in the lateral bracing structures underneath the bridge deck. The harvester was integrated off-board with a power conditioning circuit and a wireless mote. Duty- cycled wireless transmissions from the vibration-powered mote was successfully sustained by the recovered ambient energy. This limited duration field test provides the initial validation for realising vibration-powered wireless structural health monitoring systems in real world infrastructure, where the vibration profile is both broadband and intermittent. (paper)

  14. A vibration powered wireless mote on the Forth Road Bridge

    Science.gov (United States)

    Jia, Yu; Yan, Jize; Feng, Tao; Du, Sijun; Fidler, Paul; Soga, Kenichi; Middleton, Campbell; Seshia, Ashwin A.

    2015-12-01

    The conventional resonant-approaches to scavenge kinetic energy are typically confined to narrow and single-band frequencies. The vibration energy harvester device reported here combines both direct resonance and parametric resonance in order to enhance the power responsiveness towards more efficient harnessing of real-world ambient vibration. A packaged electromagnetic harvester designed to operate in both of these resonant regimes was tested in situ on the Forth Road Bridge. In the field-site, the harvester, with an operational volume of ∼126 cm3, was capable of recovering in excess of 1 mW average raw AC power from the traffic-induced vibrations in the lateral bracing structures underneath the bridge deck. The harvester was integrated off-board with a power conditioning circuit and a wireless mote. Duty- cycled wireless transmissions from the vibration-powered mote was successfully sustained by the recovered ambient energy. This limited duration field test provides the initial validation for realising vibration-powered wireless structural health monitoring systems in real world infrastructure, where the vibration profile is both broadband and intermittent.

  15. Writing short alarm messages : A matter of education, training and practice

    NARCIS (Netherlands)

    Jagtman, H.M.

    2013-01-01

    The Netherlands has a new tool to alarm and inform the population in case of crises. NL-Alert can simultaneously draw people’s attention and explain the crisis matter. The use requires determining of both the impact area and the alarm text. This raises questions about required knowledge and

  16. Damage Detection by Laser Vibration Measurement

    Directory of Open Access Journals (Sweden)

    Elena Daniela Birdeanu

    2008-10-01

    Full Text Available The technique based on the vibration analysis by scanning laser Doppler vibrometer is one of the most promising, allowing to extract also small defect and to directly correlate it to local dynamic stiffness and structural integrity. In fact, the measurement capabilities of vibrometers, such as sensitivity, accuracy and reduced intrusively, allow having a very powerful instrument in diagnostic.

  17. A proactive alarm reduction method and its human factors validation test for a main control room for SMART

    International Nuclear Information System (INIS)

    Jang, Gwi-sook; Suh, Sang-moon; Kim, Sa-kil; Suh, Yong-suk; Park, Je-yun

    2013-01-01

    Highlights: ► A proactive alarm reduction method improves effectiveness on the alarm reduction. ► The method suppresses alarms based on the ECA rules and facts for the alarm reduction under an alarm flood situation. ► The alarm reduction logics are supplemented to a high hit ratio of the reduction logics during on-line operations. ► The method is validated by human factors validation test based on regulatory requirements. -- Abstract: Conventional alarm systems tend to overwhelm operators during a transient because of a large number of nearly simultaneous annunciator activations with varying degrees of relevance to operator tasks. Thus alarm processing techniques have developed to support operators in coping with the volume of alarms, to identify which alarms are significant, and to reduce the need for operators to infer the plant conditions. This paper proposes a proactive alarm reduction method for SMART (System-integrated Modular Advanced ReacTor) whereby based on the contents of the past operating effects alarm reduction is carried out during the next transient. We designed and implemented the proactive alarm reduction system and constructed the environment for the human factors validation test. Also, eight subjects actually working in a nuclear power plant (NPP) tested the practical effectiveness of the proposed proactive alarm reduction method according to the procedure of human factors validation test under a dynamic simulation of a partial scope for an NPP.

  18. Effects of integrated designs of alarm and process information on diagnosis performance in digital nuclear power plants.

    Science.gov (United States)

    Wu, Xiaojun; She, Manrong; Li, Zhizhong; Song, Fei; Sang, Wei

    2017-12-01

    In the main control rooms of nuclear power plants (NPPs), operators frequently switch between alarm displays and system-information displays to incorporate information from different screens. In this study, we investigated two integrated designs of alarm and process information - integrating alarm information into process displays (denoted as Alarm2Process integration) and integrating process information into alarm displays (denoted as Process2Alarm integration). To analyse the effects of the two integration approaches and time pressure on the diagnosis performance, a laboratory experiment was conducted with ninety-six students. The results show that compared with the non-integrated case, Process2Alarm integration yields better diagnosis performance in terms of diagnosis accuracy, time required to generate correct hypothesis and completion time. In contrast, the Alarm2Process integration leads to higher levels of workload, with no improvement in diagnosis performance. The diagnosis performance of Process2Alarm integration was consistently better than that of Alarm2Process integration, regardless of the levels of time pressure. Practitioner Summary: To facilitate operator's synthesis of NPP information when performing diagnosis tasks, we proposed to integrate process information into alarm displays. The laboratory validation shows that the integration approach significantly improves the diagnosis performance for both low and high time-pressure levels.

  19. Comparison of sound propagation and perception of three types of backup alarms with regards to worker safety

    Directory of Open Access Journals (Sweden)

    Véronique Vaillancourt

    2013-01-01

    Full Text Available A technology of backup alarms based on the use of a broadband signal has recently gained popularity in many countries. In this study, the performance of this broadband technology is compared to that of a conventional tonal alarm and a multi-tone alarm from a worker-safety standpoint. Field measurements of sound pressure level patterns behind heavy vehicles were performed in real work environments and psychoacoustic measurements (sound detection thresholds, equal loudness, perceived urgency and sound localization were carried out in the laboratory with human subjects. Compared with the conventional tonal alarm, the broadband alarm generates a much more uniform sound field behind vehicles, is easier to localize in space and is judged slighter louder at representative alarm levels. Slight advantages were found with the tonal alarm for sound detection and for perceived urgency at low levels, but these benefits observed in laboratory conditions would not overcome the detrimental effects associated with the large and abrupt variations in sound pressure levels (up to 15-20 dB within short distances observed in the field behind vehicles for this alarm, which are significantly higher than those obtained with the broadband alarm. Performance with the multi-tone alarm generally fell between that of the tonal and broadband alarms on most measures.

  20. Percutaneous nephrolithotomy; alarming variables for postoperative bleeding

    Directory of Open Access Journals (Sweden)

    Shakhawan H.A. Said

    2017-03-01

    Conclusion: According to our present results stone complexity (GSS grade 3 and 4, history of ipsilateral renal stone surgery, and occurrence of intraoperative pelvicalyceal perforation are alarming variables for post-PCNL bleeding.

  1. Enhanced vibration diagnostics using vibration signature analysis

    International Nuclear Information System (INIS)

    Ahmed, S.; Shehzad, K.; Zahoor, Y.; Mahmood, A.; Bibi, A.

    2001-01-01

    Symptoms will appear in equipment, as well as in human beings. when 'suffering from sickness. Symptoms of abnormality in equipment are vibration, noise, deformation, temperature, pressure, electric current, crack, wearing, leakage etc. these are called modes of failure. If the mode of failure is vibration then the vibration signature analysis can be effectively used in order to diagnose the machinery problems. Much valuable information is contained within these vibration 'Spectra' or 'Signatures' but is only of use if the analyst can unlock its 'Secrets'. This paper documents a vibration problem in the motor of a centrifugal pump (Type ETA). It focuses mainly on the roll of modern vibration monitoring system in problem analysis. The problem experienced was the motor unstability and noise due to high vibration. Using enhanced vibration signature data, the problem was analyzed. which suggested that the rotor eccentricity was the cause of excessive noise and vibration in the motor. In conclusion, advanced electronic monitoring and diagnostic systems provide powerful information for machine's condition assessment and problem analysis. Appropriate interpretation and use of this information is important for accurate and effective vibration analysis. (author)

  2. Stimulus-response time to alarms of the intra-aortic balloon pump: safe care practices

    Directory of Open Access Journals (Sweden)

    Andrezza Serpa Franco

    Full Text Available ABSTRACT Objective: To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. Method: This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. Results: The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. Conclusion: Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology.

  3. 10 CFR 74.57 - Alarm resolution.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Alarm resolution. 74.57 Section 74.57 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) MATERIAL CONTROL AND ACCOUNTING OF SPECIAL NUCLEAR MATERIAL Formula... unresolved beyond the time period specified for its resolution in the licensee's fundamental nuclear material...

  4. Development of Alarm System link Drawing for Operation Support for APR1400 Digital Main Control Room

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki-Hwan [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    Digitalized MMI(Man-Machine Interface) including Digital Main Control Room(MCR) and digital I and C system was being applied for SKN 3 and 4 Nuclear Power Plant(NPP) and subsequent APR1400 NPP type. But, operators can not easily find instrument for alarm immediately. Therefore, Alarm system is required to easily find instrument for Alarm. For this implementation, we will plan system design considering design feature without affecting network load and CPU load. We have developed Alarm system link drawing for digital MCR. Operators of the digitalized MCR navigates from their consoles to the drawings related to the plant alarms and their instruments or the operation status. Such method gives cognitive load to the operators having to travel to different locations in finding the related information. Screen Sharing System, which is the fundamental technique for Drawing Interconnection Alarm System is close to completion, and it should be functionally tested and verified by the human factor engineering. For the actual application to the operating plants, the drawings to be interconnected to the alarms and the opinions from the operators/maintenance departments for designating alarm number should be surveyed, Also, another function that allows the access to the alarm related drawings not only from the MCR but also from the other offices.

  5. Receivers matter: the meaning of alarm calls and competition for nest sites in a bird community.

    Science.gov (United States)

    Parejo, Deseada; Avilés, Jesús M; Expósito-Granados, Mónica

    2018-04-11

    Animal communities may constitute information networks where individuals gain information on predation risk by eavesdropping on alarm calls of other species. However, communities include species in different trophic levels, and it is not yet known how the trophic level of the receiver influences the informative value of a call. Furthermore, no empirical study has yet tested how increased competition may influence the value of alarm calls for distinct receivers. Here, we identify the importance of alarm calls emitted by a small owl, the little owl (Athene noctua), on the structure of a cavity-nesting bird community including mesopredators and primary prey under variable levels of competition for nest holes. Competitors sharing top predators with the callers and prey of the callers interpreted alarm and non-alarm calls differently. Competitors chose preferentially alarm and non-alarm patches over control patches to breed, while prey selected alarm patches. In contrast, competition for nest sites affected habitat selection of prey species more than that of competitors of the callers. This study provides support for a changing value of alarm calls and competition for nest sites for distinct receivers related to niche overlapping among callers and eavesdroppers, therefore, calling attention to possible cascading effects by the use of information in natural communities.

  6. Development of Alarm System link Drawing for Operation Support for APR1400 Digital Main Control Room

    International Nuclear Information System (INIS)

    Kim, Ki-Hwan

    2016-01-01

    Digitalized MMI(Man-Machine Interface) including Digital Main Control Room(MCR) and digital I and C system was being applied for SKN 3 and 4 Nuclear Power Plant(NPP) and subsequent APR1400 NPP type. But, operators can not easily find instrument for alarm immediately. Therefore, Alarm system is required to easily find instrument for Alarm. For this implementation, we will plan system design considering design feature without affecting network load and CPU load. We have developed Alarm system link drawing for digital MCR. Operators of the digitalized MCR navigates from their consoles to the drawings related to the plant alarms and their instruments or the operation status. Such method gives cognitive load to the operators having to travel to different locations in finding the related information. Screen Sharing System, which is the fundamental technique for Drawing Interconnection Alarm System is close to completion, and it should be functionally tested and verified by the human factor engineering. For the actual application to the operating plants, the drawings to be interconnected to the alarms and the opinions from the operators/maintenance departments for designating alarm number should be surveyed, Also, another function that allows the access to the alarm related drawings not only from the MCR but also from the other offices

  7. Energy harvesting from vibration using a piezoelectric membrane

    Energy Technology Data Exchange (ETDEWEB)

    Ericka, M.; Vasic, D.; Costa, F.; Tliba, S. [Ecole Normale Superieure de Cachan, Systemes et Applications des Technologies de l' Information et de l' Energie (SATIE, UMR 8029), 94 - Cachan (France); Poulin, G. [Ecole Nationale Superieure d' Ingenieurs Electriciens de Grenoble, Laboratoire d' Automatique de Grenoble, 38 (France)

    2005-09-01

    In this paper we investigate the capability of harvesting the electric energy from mechanical vibrations in a dynamic environment through a piezoelectric membrane transducer. This transducer consists of 2 layers lead zirconate titanate (PZT)/brass, the brass layer is embedded over the whole circumference by epoxy adhesive. A very small vibration gives a consequent deformation of the membrane which generates electric energy. Due to the impedance matrices connecting the efforts and flows of the membrane, we have established the dynamic electric equivalent circuit of the transducer. In a first study and in order to validate theoretical results, we performed experiments with a vibrating machine moving a macroscopic 25 mm diameter piezoelectric membrane. A power of 1.8 mW was generated at the resonance frequency (2.58 kHz) across a 56 k{omega} optimal resistor and for a 2 g acceleration. (authors)

  8. Automated analysis of off-line measured gamma-spectra using UniSampo gamma-ray spectrum analysis software including criterias for alarming systems

    International Nuclear Information System (INIS)

    Nikkinen, M.T.

    2005-01-01

    In many laboratories the number of measured routine gamma-spectra can be significant and the labour work to review all the data is time consuming and expensive task. In many cases the routine sample does not normally contain radiation above a detectable level, and still the review of the spectra has to be performed. By introducing simple rules for emerging conditions, the review work can be significantly reduced. In one case the need to review the environmental measurement spectra was reduced to less than 1% compared to the original need, which in turn made the review personnel available for more useful functions. Using the UniSampo analysis system, the analysis results of spectra that are causing alarming conditions can be transmitted via e-mail to any address. Some systems are even equipped with the capability to forward these results to hand-portable telephones or pagers. This is a very practical solution for automated environmental monitoring, when the sample spectra are collected automatically and transmitted to central computer for further analysis. Set up of an automatic analysis system, rules for the emerging conditions, technical solutions for an automated alarming system and a generic hypothesis test for the alarming system developed for UniSampo analysis software are described. (author)

  9. When one is not enough: prevalence and characteristics of homes not adequately protected by smoke alarms.

    Science.gov (United States)

    Peek-Asa, C; Allareddy, V; Yang, J; Taylor, C; Lundell, J; Zwerling, C

    2005-12-01

    The National Fire Protection Association (NFPA) has specific recommendations about the number, location, and type of smoke alarms that are needed to provide maximum protection for a household. No previous studies have examined whether or not homes are completely protected according to these guidelines. The authors describe the prevalence and home characteristics associated with compliance to recommendations for smoke alarm installation by the NFPA. Data are from the baseline on-site survey of a randomized trial to measure smoke alarm effectiveness. The trial was housed in a longitudinal cohort study in a rural Iowa county. Of 1005 homes invited, 691 (68.8%) participated. Information about smoke alarm type, placement, and function, as well as home and occupant characteristics, was collected through an on-site household survey. Although 86.0% of homes had at least one smoke alarm, only 22.3% of homes (approximately one in five) were adequately protected according to NFPA guidelines. Fourteen percent of homes had no functioning smoke alarms. More than half of the homes with smoke alarms did not have enough of them or had installed them incorrectly, and 42.4% of homes with alarms had at least one alarm that did not operate. Homes with at least one high school graduate were nearly four times more likely to be fully protected. Homes that had multiple levels, a basement, or were cluttered or poorly cleaned were significantly less likely to be fully protected. These findings indicate that consumers may not be knowledgeable about the number of alarms they need or how to properly install them. Occupants are also not adequately maintaining the alarms that are installed.

  10. Development of measurement capabilities for the thermophysical properties of energy-related fluids. Annual report, December 1, 1992--November 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Kayser, R.F.

    1993-08-13

    The measurement capabilities to be developed include new apparatus for transport properties, thermodynamic properties, phase equilibria, and dielectric properties. Specific capabilities are: Thermal conductivity apparatus, vibrating wire viscometer, dual-sinker densimeter, high-temperature vibrating tube densimeter, dynamic phase equilibria apparatus, apparatus for dilute solutions, total-enthalpy flow calorimeter. Benchmark measurements were made (no data given) on pure and mixed alternative refrigerants and their mixtures with lubricants, and other fluids.

  11. Three-dimensional piezoelectric vibration energy harvester using spiral-shaped beam with triple operating frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Nian; Yang, Jin, E-mail: yangjin@cqu.edu.cn; Yu, Qiangmo; Zhao, Jiangxin; Liu, Jun; Wen, Yumei; Li, Ping [Department of Optoelectronic Engineering, Chongqing University, Chongqing 400044 (China)

    2016-01-15

    This work has demonstrated a novel piezoelectric energy harvester without a complex structure and appended component that is capable of scavenging vibration energy from arbitrary directions with multiple resonant frequencies. In this harvester, a spiral-shaped elastic thin beam instead of a traditional thin cantilever beam was adopted to absorb external vibration with arbitrary direction in three-dimensional (3D) spaces owing to its ability to bend flexibly and stretch along arbitrary direction. Furthermore, multiple modes in the elastic thin beam contribute to a possibility to widen the working bandwidth with multiple resonant frequencies. The experimental results show that the harvester was capable of scavenging the vibration energy in 3D arbitrary directions; they also exhibited triple power peaks at about 16 Hz, 21 Hz, and 28 Hz with the powers of 330 μW, 313 μW, and 6 μW, respectively. In addition, human walking and water wave energies were successfully converted into electricity, proving that our harvester was practical to scavenge the time-variant or multi-directional vibration energies in our daily life.

  12. Three-dimensional piezoelectric vibration energy harvester using spiral-shaped beam with triple operating frequencies

    Science.gov (United States)

    Zhao, Nian; Yang, Jin; Yu, Qiangmo; Zhao, Jiangxin; Liu, Jun; Wen, Yumei; Li, Ping

    2016-01-01

    This work has demonstrated a novel piezoelectric energy harvester without a complex structure and appended component that is capable of scavenging vibration energy from arbitrary directions with multiple resonant frequencies. In this harvester, a spiral-shaped elastic thin beam instead of a traditional thin cantilever beam was adopted to absorb external vibration with arbitrary direction in three-dimensional (3D) spaces owing to its ability to bend flexibly and stretch along arbitrary direction. Furthermore, multiple modes in the elastic thin beam contribute to a possibility to widen the working bandwidth with multiple resonant frequencies. The experimental results show that the harvester was capable of scavenging the vibration energy in 3D arbitrary directions; they also exhibited triple power peaks at about 16 Hz, 21 Hz, and 28 Hz with the powers of 330 μW, 313 μW, and 6 μW, respectively. In addition, human walking and water wave energies were successfully converted into electricity, proving that our harvester was practical to scavenge the time-variant or multi-directional vibration energies in our daily life.

  13. Three-dimensional piezoelectric vibration energy harvester using spiral-shaped beam with triple operating frequencies

    International Nuclear Information System (INIS)

    Zhao, Nian; Yang, Jin; Yu, Qiangmo; Zhao, Jiangxin; Liu, Jun; Wen, Yumei; Li, Ping

    2016-01-01

    This work has demonstrated a novel piezoelectric energy harvester without a complex structure and appended component that is capable of scavenging vibration energy from arbitrary directions with multiple resonant frequencies. In this harvester, a spiral-shaped elastic thin beam instead of a traditional thin cantilever beam was adopted to absorb external vibration with arbitrary direction in three-dimensional (3D) spaces owing to its ability to bend flexibly and stretch along arbitrary direction. Furthermore, multiple modes in the elastic thin beam contribute to a possibility to widen the working bandwidth with multiple resonant frequencies. The experimental results show that the harvester was capable of scavenging the vibration energy in 3D arbitrary directions; they also exhibited triple power peaks at about 16 Hz, 21 Hz, and 28 Hz with the powers of 330 μW, 313 μW, and 6 μW, respectively. In addition, human walking and water wave energies were successfully converted into electricity, proving that our harvester was practical to scavenge the time-variant or multi-directional vibration energies in our daily life

  14. Three-dimensional piezoelectric vibration energy harvester using spiral-shaped beam with triple operating frequencies.

    Science.gov (United States)

    Zhao, Nian; Yang, Jin; Yu, Qiangmo; Zhao, Jiangxin; Liu, Jun; Wen, Yumei; Li, Ping

    2016-01-01

    This work has demonstrated a novel piezoelectric energy harvester without a complex structure and appended component that is capable of scavenging vibration energy from arbitrary directions with multiple resonant frequencies. In this harvester, a spiral-shaped elastic thin beam instead of a traditional thin cantilever beam was adopted to absorb external vibration with arbitrary direction in three-dimensional (3D) spaces owing to its ability to bend flexibly and stretch along arbitrary direction. Furthermore, multiple modes in the elastic thin beam contribute to a possibility to widen the working bandwidth with multiple resonant frequencies. The experimental results show that the harvester was capable of scavenging the vibration energy in 3D arbitrary directions; they also exhibited triple power peaks at about 16 Hz, 21 Hz, and 28 Hz with the powers of 330 μW, 313 μW, and 6 μW, respectively. In addition, human walking and water wave energies were successfully converted into electricity, proving that our harvester was practical to scavenge the time-variant or multi-directional vibration energies in our daily life.

  15. Sum frequency generation for surface vibrational spectroscopy

    International Nuclear Information System (INIS)

    Hunt, J.H.; Guyot-Sionnest, P.; Shen, Y.R.

    1987-01-01

    Surface vibrational spectroscopy is one of the best means for characterizing molecular adsorbates. For this reason, many techniques have been developed in the past. However, most of them suffer from poor sensitivity, low spectral and temporal resolution, and applications limited to vacuum solid interfaces. Recently, the second harmonic generation (SHG) technique was proved repeatedly to be a simple but versatile surface probe. It is highly sensitive and surface specific; it is also capable of achieving high temporal, spatial, and spectral resolution. Being an optical technique, it can be applied to any interface accessible by light. The only serious drawback is its lack of molecular selectivity. An obvious remedy is the extension of the technique to IR-visible sum frequency generation (SFG). Surface vibrational spectroscopy with submonolayer sensitivity is then possible using SFG with the help of a tunable IR laser. The authors report here an SFG measurement of the C-H stretch vibration of monolayers of molecules at air-solid and air-liquid interfaces

  16. The heuristics of nurse responsiveness to critical patient monitor and ventilator alarms in a private room neonatal intensive care unit.

    Science.gov (United States)

    Joshi, Rohan; Mortel, Heidi van de; Feijs, Loe; Andriessen, Peter; Pul, Carola van

    2017-01-01

    Alarm fatigue is a well-recognized patient safety concern in intensive care settings. Decreased nurse responsiveness and slow response times to alarms are the potentially dangerous consequences of alarm fatigue. The aim of this study was to determine the factors that modulate nurse responsiveness to critical patient monitor and ventilator alarms in the context of a private room neonatal intensive care setting. The study design comprised of both a questionnaire and video monitoring of nurse-responsiveness to critical alarms. The Likert scale questionnaire, comprising of 50 questions across thematic clusters (critical alarms, yellow alarms, perception, design, nursing action, and context) was administered to 56 nurses (90% response rate). Nearly 6000 critical alarms were recorded from 10 infants in approximately 2400 hours of video monitoring. Logistic regression was used to identify patient and alarm-level factors that modulate nurse-responsiveness to critical alarms, with a response being defined as a nurse entering the patient's room within the 90s of the alarm being generated. Based on the questionnaire, the majority of nurses found critical alarms to be clinically relevant even though the alarms did not always mandate clinical action. Based on video observations, for a median of 34% (IQR, 20-52) of critical alarms, the nurse was already present in the room. For the remaining alarms, the response rate within 90s was 26%. The median response time was 55s (IQR, 37-70s). Desaturation alarms were the most prevalent and accounted for more than 50% of all alarms. The odds of responding to bradycardia alarms, compared to desaturation alarms, were 1.47 (95% CI = 1.21-1.78; heuristics in determining whether or not to respond to the alarm. Amongst other factors, the category and duration of critical alarms along with the clinical status of the patient determine nurse-responsiveness to alarms.

  17. The use of simulation in the development of human factors guidelines for alarm systems

    International Nuclear Information System (INIS)

    O'Hara, J.; Brown, W.S.; Wachtel, J.; Persensky, J.

    1997-01-01

    This paper describes a research program sponsored by the US Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. As part of this program, guidance was developed based on a broad review and analysis of technical and research literature. In the course of guidance development, aspects of alarm system design for which the technical basis was insufficient to support guidance developed were identified. Experimental research is currently underway to address the highest priority topics: alarm processing and display characteristics. This paper provides an overview of the approach to guidance development and discusses the role of simulation in the development approach. Finally, the current simulator-based experiment is described to illustrate how the alarm system design features are being studied

  18. Reevaluation of the PMS alarm set-points in OPR1000

    International Nuclear Information System (INIS)

    Roh, Kyung Ho; Yang, Sung Tae; Jung, Sung In

    2011-01-01

    In Optimized Power Reactor 1000 (OPR1000), the common alarm of the plant monitoring system (PMS), which is related to the channel-to-channel core protection calculator (CPC), experiences frequent deviations in the departure from nucleate boiling ratio (DNBR) and the local power density (LPD) between the middle of the cycle and the end of the cycle. Because the channel-to-channel CPC causes deviations in the values of the DNBR and LPD, the increase in the CPC input variables exceeds the alarm set-points. The CPC DNBR and LPD are defined as follows: Deviation = the average of four CPC channels of the LPD and DNBR minus the value of each CPC channel LPD and DNBR. In this paper, we report on a review by the Korea Hydro and Nuclear Power Co., Ltd. (KHNP) regarding the suitability of the alarm set-points for the channel-tochannel deviations of the CPC DNBR and LPD. The set-points were revaluated in light of operational experience and the case of Palo Verde (which is the reference model of OPR1000). The KHNP consequently revised the relevant procedures, as well as and the PMS alarm set-points, as part of its follow-up action

  19. Silicon Micromachined Sensor for Broadband Vibration Analysis

    Science.gov (United States)

    Gutierrez, Adolfo; Edmans, Daniel; Cormeau, Chris; Seidler, Gernot; Deangelis, Dave; Maby, Edward

    1995-01-01

    The development of a family of silicon based integrated vibration sensors capable of sensing mechanical resonances over a broad range of frequencies with minimal signal processing requirements is presented. Two basic general embodiments of the concept were designed and fabricated. The first design was structured around an array of cantilever beams and fabricated using the ARPA sponsored multi-user MEMS processing system (MUMPS) process at the Microelectronics Center of North Carolina (MCNC). As part of the design process for this first sensor, a comprehensive finite elements analysis of the resonant modes and stress distribution was performed using PATRAN. The dependence of strain distribution and resonant frequency response as a function of Young's modulus in the Poly-Si structural material was studied. Analytical models were also studied. In-house experimental characterization using optical interferometry techniques were performed under controlled low pressure conditions. A second design, intended to operate in a non-resonant mode and capable of broadband frequency response, was proposed and developed around the concept of a cantilever beam integrated with a feedback control loop to produce a null mode vibration sensor. A proprietary process was used to integrat a metal-oxide semiconductor (MOS) sensing device, with actuators and a cantilever beam, as part of a compatible process. Both devices, once incorporated as part of multifunction data acquisition and telemetry systems will constitute a useful system for NASA launch vibration monitoring operations. Satellite and other space structures can benefit from the sensor for mechanical condition monitoring functions.

  20. Real-time Alarm Monitoring System for Detecting Driver Fatigue in Wireless Areas

    Directory of Open Access Journals (Sweden)

    Rongrong Fu

    2017-04-01

    Full Text Available The purpose of this paper was to develop a real-time alarm monitoring system that can detect the fatigue driving state through wireless communication. The drivers’ electroencephalogram (EEG signals were recorded from occipital electrodes. Seven EEG rhythms with different frequency bands as gamma, hbeta, beta, sigma, alpha, theta and delta waves were extracted. They were simultaneously assessed using relative operating characteristic (ROC curves and grey relational analysis to select one as the fatigue feature. The research results showed that the performance of theta wave was the best one. Therefore, theta wave was used as fatigue feature in the following alarm device. The real-time alarm monitoring system based on the result has been developed, once the threshold was settled by using the data of the first ten minutes driving period. The developed system can detect driver fatigue and give alarm to indicate the onset of fatigue automatically.

  1. Passive and active vibration isolation systems using inerter

    Science.gov (United States)

    Alujević, N.; Čakmak, D.; Wolf, H.; Jokić, M.

    2018-03-01

    This paper presents a theoretical study on passive and active vibration isolation schemes using inerter elements in a two degree of freedom (DOF) mechanical system. The aim of the work is to discuss basic capabilities and limitations of the vibration control systems at hand using simple and physically transparent models. Broad frequency band dynamic excitation of the source DOF is assumed. The purpose of the isolator system is to prevent vibration transmission to the receiving DOF. The frequency averaged kinetic energy of the receiving mass is used as the metric for vibration isolation quality. It is shown that the use of inerter element in the passive vibration isolation scheme can enhance the isolation effect. In the active case, a feedback disturbance rejection scheme is considered. Here, the error signal is the receiving body absolute velocity which is directly fed to a reactive force actuator between the source and the receiving bodies. In such a scheme, the so-called subcritical vibration isolation problems exist. These problems are characterised by the uncoupled natural frequency of the receiving body larger than the uncoupled natural frequency of the source body. In subcritical vibration isolation problems, the performance of the active control is limited by poor stability margins. This is because the stable feedback gain is restricted in a narrow range between a minimum and a maximum. However, with the inclusion of an inerter in the isolator, one of the two stability margins can be opened. This enables large, theoretically unlimited negative feedback gains and large active damping of the receiving body vibration. A simple expression for the required inertance is derived.

  2. Habituation of adult sea lamprey repeatedly exposed to damage-released alarm and predator cues

    Science.gov (United States)

    Imre, Istvan; Di Rocco, Richard T.; Brown, Grant E.; Johnson, Nicholas

    2016-01-01

    Predation is an unforgiving selective pressure affecting the life history, morphology and behaviour of prey organisms. Selection should favour organisms that have the ability to correctly assess the information content of alarm cues. This study investigated whether adult sea lamprey Petromyzon marinus habituate to conspecific damage-released alarm cues (fresh and decayed sea lamprey extract), a heterospecific damage-released alarm cue (white sucker Catostomus commersoniiextract), predator cues (Northern water snake Nerodia sipedon washing, human saliva and 2-phenylethylamine hydrochloride (PEA HCl)) and a conspecific damage-released alarm cue and predator cue combination (fresh sea lamprey extract and human saliva) after they were pre-exposed 4 times or 8 times, respectively, to a given stimulus the previous night. Consistent with our prediction, adult sea lamprey maintained an avoidance response to conspecific damage-released alarm cues (fresh and decayed sea lamprey extract), a predator cue presented at high relative concentration (PEA HCl) and a conspecific damage-released alarm cue and predator cue combination (fresh sea lamprey extract plus human saliva), irrespective of previous exposure level. As expected, adult sea lamprey habituated to a sympatric heterospecific damage-released alarm cue (white sucker extract) and a predator cue presented at lower relative concentration (human saliva). Adult sea lamprey did not show any avoidance of the Northern water snake washing and the Amazon sailfin catfish extract (heterospecific control). This study suggests that conspecific damage-released alarm cues and PEA HCl present the best options as natural repellents in an integrated management program aimed at controlling the abundance of sea lamprey in the Laurentian Great Lakes.

  3. Krohne Flow Indicator and High Flow Alarm - Local Indicator and High Flow Alarm of Helium Flow from the SCHe Purge Lines C and D to the Process Vent

    International Nuclear Information System (INIS)

    MISKA, C.R.

    2000-01-01

    Flow Indicators/alarms FI/FSH-5*52 and -5*72 are located in the process vent lines connected to the 2 psig SCHe purge lines C and D. They monitor the flow from the 2 psig SCHe purge going to the process vent. The switch/alarm is non-safety class GS

  4. Masters Thesis- Criticality Alarm System Design Guide with Accompanying Alarm System Development for the Radioisotope Production Laboratory in Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Greenfield, Bryce A. [Univ. of New Mexico, Albuquerque, NM (United States)

    2009-12-01

    A detailed instructional manual was created to guide criticality safety engineers through the process of designing a criticality alarm system (CAS) for Department of Energy (DOE) hazard class 1 and 2 facilities. Regulatory and technical requirements were both addressed. A list of design tasks and technical subtasks are thoroughly analyzed to provide concise direction for how to complete the analysis. An example of the application of the design methodology, the Criticality Alarm System developed for the Radioisotope Production Laboratory (RPL) of Richland, Washington is also included. The analysis for RPL utilizes the Monte Carlo code MCNP5 for establishing detector coverage in the facility. Significant improvements to the existing CAS were made that increase the reliability, transparency, and coverage of the system.

  5. Expert System Constant False Alarm Rate (CFAR) Processor

    National Research Council Canada - National Science Library

    Wicks, Michael C

    2006-01-01

    An artificial intelligence system improves radar signal processor performance by increasing target probability of detection and reducing probability of false alarm in a severe radar clutter environment...

  6. Planetary Gearbox Fault Detection Using Vibration Separation Techniques

    Science.gov (United States)

    Lewicki, David G.; LaBerge, Kelsen E.; Ehinger, Ryan T.; Fetty, Jason

    2011-01-01

    Studies were performed to demonstrate the capability to detect planetary gear and bearing faults in helicopter main-rotor transmissions. The work supported the Operations Support and Sustainment (OSST) program with the U.S. Army Aviation Applied Technology Directorate (AATD) and Bell Helicopter Textron. Vibration data from the OH-58C planetary system were collected on a healthy transmission as well as with various seeded-fault components. Planetary fault detection algorithms were used with the collected data to evaluate fault detection effectiveness. Planet gear tooth cracks and spalls were detectable using the vibration separation techniques. Sun gear tooth cracks were not discernibly detectable from the vibration separation process. Sun gear tooth spall defects were detectable. Ring gear tooth cracks were only clearly detectable by accelerometers located near the crack location or directly across from the crack. Enveloping provided an effective method for planet bearing inner- and outer-race spalling fault detection.

  7. Development and Application of a Clinical Microsystem Simulation Methodology for Human Factors-Based Research of Alarm Fatigue.

    Science.gov (United States)

    Kobayashi, Leo; Gosbee, John W; Merck, Derek L

    2017-07-01

    (1) To develop a clinical microsystem simulation methodology for alarm fatigue research with a human factors engineering (HFE) assessment framework and (2) to explore its application to the comparative examination of different approaches to patient monitoring and provider notification. Problems with the design, implementation, and real-world use of patient monitoring systems result in alarm fatigue. A multidisciplinary team is developing an open-source tool kit to promote bedside informatics research and mitigate alarm fatigue. Simulation, HFE, and computer science experts created a novel simulation methodology to study alarm fatigue. Featuring multiple interconnected simulated patient scenarios with scripted timeline, "distractor" patient care tasks, and triggered true and false alarms, the methodology incorporated objective metrics to assess provider and system performance. Developed materials were implemented during institutional review board-approved study sessions that assessed and compared an experimental multiparametric alerting system with a standard monitor telemetry system for subject response, use characteristics, and end-user feedback. A four-patient simulation setup featuring objective metrics for participant task-related performance and response to alarms was developed along with accompanying structured HFE assessment (questionnaire and interview) for monitor systems use testing. Two pilot and four study sessions with individual nurse subjects elicited true alarm and false alarm responses (including diversion from assigned tasks) as well as nonresponses to true alarms. In-simulation observation and subject questionnaires were used to test the experimental system's approach to suppressing false alarms and alerting providers. A novel investigative methodology applied simulation and HFE techniques to replicate and study alarm fatigue in controlled settings for systems assessment and experimental research purposes.

  8. 46 CFR 95.15-30 - Alarms.

    Science.gov (United States)

    2010-10-01

    ... navigated, other than paint and lamp lockers and similar small spaces, shall be fitted with an approved... only for systems required to be fitted with a delayed discharge. Such alarms shall be so arranged as to sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and the...

  9. Emergency Response Capability Baseline Needs Assessment Compliance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, John A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-09-16

    This document is the second of a two-part analysis of Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2013 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2009 BNA, the 2012 BNA document, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures.

  10. Vibration-free stirling cryocooler for high definition microscopy

    Science.gov (United States)

    Riabzev, S. V.; Veprik, A. M.; Vilenchik, H. S.; Pundak, N.; Castiel, E.

    2009-12-01

    The normal operation of high definition Scanning Electronic and Helium Ion microscope tools often relies on maintaining particular components at cryogenic temperatures. This has traditionally been accomplished by using liquid coolants such as liquid Nitrogen. This inherently limits the useful temperature range to above 77 K, produces various operational hazards and typically involves elevated ownership costs, inconvenient logistics and maintenance. Mechanical coolers, over-performing the above traditional method and capable of delivering required (even below 77 K) cooling to the above cooled components, have been well-known elsewhere for many years, but their typical drawbacks, such as high purchasing cost, cooler size, low reliability and high power consumption have so far prevented their wide-spreading. Additional critical drawback is inevitable degradation of imagery performance originated from the wideband vibration export as typical for the operation of the mechanical cooler incorporating numerous movable components. Recent advances in the development of reliable, compact, reasonably priced and dynamically quiet linear cryogenic coolers gave rise to so-called "dry cooling" technologies aimed at eventually replacing the traditional use of outdated liquid Nitrogen cooling facilities. Although much improved these newer cryogenic coolers still produce relatively high vibration export which makes them incompatible with modern high definition microscopy tools. This has motivated further research activity towards developing a vibration free closed-cycle mechanical cryocooler. The authors have successfully adapted the standard low vibration Stirling cryogenic refrigerator (Ricor model K535-LV) delivering 5 W@40 K heat lift for use in vibration-sensitive high definition microscopy. This has been achieved by using passive mechanical counterbalancing of the main portion of the low frequency vibration export in combination with an active feed-forward multi

  11. Alarm analysis of secondary loop system based on MFM and SDG methods

    International Nuclear Information System (INIS)

    Yang Ning; Lu Gubing; Chen Pan

    2014-01-01

    The multilevel flow model (MFM) and the signed directed graph (SDG) were combined to analyze the alarm signals of the secondary loop system for nuclear power plant. The MFM was used to delaminate and describe nuclear power plant, and the SDG was used to analyze the logicality of the facility sign in the MFM. Two kinds of faults in the secondary loop system in nuclear power plant were simulated and the alarm signals were analyzed. The simulation results show that the fault source can be identified exactly and the transmit route of the alarm signals can be described clearly, which is helpful for operators to judge. (authors)

  12. Comparison of beam and shell theories for the vibrations of thin turbomachinery blades

    Science.gov (United States)

    Leissa, A. W.; Ewing, M. S.

    1982-01-01

    Vibration analysis of turbomachinery blades has traditionally been carried out by means of beam theory. In recent years two-dimensional methods of blade vibration analysis have been developed, most of which utilize finite elements and tend to require considerable computation time. More recently a two-dimensional method of blade analysis has evolved which does not require finite elements and is based upon shell equations. The present investigation has the primary objective to demonstrate the accuracy and limitations of blade vibration analyses which utilize one-dimensional, beam theories. It is found that beam theory is generally inadequate to determine the free vibration frequencies and mode shapes of moderate to low aspect ratio turbomachinery blades. The shallow shell theory, by contrast, is capable of representing all the vibration modes accurately. However, the one-dimensional beam theory has an important advantage over the two-dimensional shell theory for blades and vibration modes. It uses fewer degrees of freedom, thus requiring less computer time.

  13. Measuring frequency of one-dimensional vibration with video camera using electronic rolling shutter

    Science.gov (United States)

    Zhao, Yipeng; Liu, Jinyue; Guo, Shijie; Li, Tiejun

    2018-04-01

    Cameras offer a unique capability of collecting high density spatial data from a distant scene of interest. They can be employed as remote monitoring or inspection sensors to measure vibrating objects because of their commonplace availability, simplicity, and potentially low cost. A defect of vibrating measurement with the camera is to process the massive data generated by camera. In order to reduce the data collected from the camera, the camera using electronic rolling shutter (ERS) is applied to measure the frequency of one-dimensional vibration, whose frequency is much higher than the speed of the camera. Every row in the image captured by the ERS camera records the vibrating displacement at different times. Those displacements that form the vibration could be extracted by local analysis with sliding windows. This methodology is demonstrated on vibrating structures, a cantilever beam, and an air compressor to identify the validity of the proposed algorithm. Suggestions for applications of this methodology and challenges in real-world implementation are given at last.

  14. The acute physiological stress response to an emergency alarm and mobilization during the day and at night.

    Science.gov (United States)

    Hall, Sarah J; Aisbett, Brad; Tait, Jamie L; Turner, Anne I; Ferguson, Sally A; Main, Luana C

    2016-01-01

    The purpose of this study was to investigate the acute physiological stress response to an emergency alarm and mobilization during the day and at night. Sixteen healthy males aged 25 ± 4 years (mean ± SD) spent four consecutive days and nights in a sleep laboratory. This research used a within-participants design with repeated measures for time, alarm condition (alarm or control), and trial (day or night). When an alarm sounded, participants were required to mobilize immediately. Saliva samples for cortisol analysis were collected 0 min, 15 min, 30 min, 45 min, 60 min, 90 min, and 120 min after mobilization, and at corresponding times in control conditions. Heart rate was measured continuously throughout the study. Heart rate was higher in the day (F(20,442) = 9.140, P night (F(23,459) = 8.356, P day alarm and day control conditions. Cortisol was higher (F(6,183) = 2.450, P night alarm and mobilization compared to the night control condition. The magnitude of difference in cortisol between night control and night alarm conditions was greater (F(6,174) = 4.071, P day control and day alarm conditions. The augmented heart rate response to the day and night alarms supports previous observations in field settings. Variations in the cortisol responses between conditions across the day and night may relate to differences in participants' ability to interpret the alarm when sleeping versus when awake.

  15. The effects of vibration-reducing gloves on finger vibration

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2015-01-01

    Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new

  16. Experimental Study of the Ultrasonic Vibration-Assisted Abrasive Waterjet Micromachining the Quartz Glass

    Directory of Open Access Journals (Sweden)

    Rongguo Hou

    2018-01-01

    Full Text Available The ultrasonic vibration is used to enhance the capability of the abrasive water micromachining glass. And, the ultrasonic vibration is activated on the abrasive waterjet nozzle. The quality of the flow is improved, and the velocity of the abrasive is increased because of the addition of the ultrasonic energy. The relevant experimental results indicate that the erosion depth and the material volume removal of the glass are obviously increased when ultrasonic vibration is working. As for the influence of process parameters on the material removal of the glass such as vibration amplitude, system pressure, distance of the standoff, and abrasive size, the experimental results indicate that the system pressure and vibration contribute greatly to the glass material removal. Also, the erosion depth and the volume of material removal are increased with the increase in the vibration amplitude and system pressure. There are some uplifts found at the edge of erosion pit. Then, it can be inferred that the plastic method is an important material removal method during the machining process of ultrasonic vibration-assisted abrasive waterjet.

  17. Changes are detected - cameras and video systems are monitoring the plant site, only rarely giving false alarm

    International Nuclear Information System (INIS)

    Zeissler, H.

    1988-01-01

    The main purpose of automatic data acquisition and processing for monitoring goals is to relieve the security personnel from monotonous observation tasks. The novel video systems can be programmed to detect moving target alarm signals, or accept alarm-suppressing image changes. This allows an intelligent alarm evaluation for physical protection in industry, differentiating between real and false alarm signals. (orig.) [de

  18. Piezoelectric Vibration Damping Study for Rotating Composite Fan Blades

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Choi, Benjamin B.; Provenza, Andrew J.; Kray, Nicholas

    2012-01-01

    Resonant vibrations of aircraft engine blades cause blade fatigue problems in engines, which can lead to thicker and aerodynamically lower performing blade designs, increasing engine weight, fuel burn, and maintenance costs. In order to mitigate undesirable blade vibration levels, active piezoelectric vibration control has been investigated, potentially enabling thinner blade designs for higher performing blades and minimizing blade fatigue problems. While the piezoelectric damping idea has been investigated by other researchers over the years, very little study has been done including rotational effects. The present study attempts to fill this void. The particular objectives of this study were: (a) to develop and analyze a multiphysics piezoelectric finite element composite blade model for harmonic forced vibration response analysis coupled with a tuned RLC circuit for rotating engine blade conditions, (b) to validate a numerical model with experimental test data, and (c) to achieve a cost-effective numerical modeling capability which enables simulation of rotating blades within the NASA Glenn Research Center (GRC) Dynamic Spin Rig Facility. A numerical and experimental study for rotating piezoelectric composite subscale fan blades was performed. It was also proved that the proposed numerical method is feasible and effective when applied to the rotating blade base excitation model. The experimental test and multiphysics finite element modeling technique described in this paper show that piezoelectric vibration damping can significantly reduce vibrations of aircraft engine composite fan blades.

  19. Moving Towards a Common Alarm Service for the LHC Era

    CERN Document Server

    Calderini, F; Stapley, N; Tyrell, M W

    2003-01-01

    The Large Hadron Collider (LHC) is one of the greatest technological challenges ever faced by accelerator builders. It is due for commissioning in 4 years and will have a lifetime well in excess of 10. The LHC will contain a completely heterogeneous mixture of industrial controls, both hardware and software, as well as dedicated, specialised, 'home' built systems. As part of the control infrastructure of such a complex machine, a number of 'services' will be essential as aids during operation, such as: logging / archiving, post-mortem, sequences, alarm system, etc. This paper describes the approach to be taken in order to define and provide the alarm service necessary for LHC. Details will be given of: the graceful transition from the current LEP alarm system; accommodating the SPS, PS and CERN's technical services; the technologies to be used; the approach of parallel investigations of industrial and 'home' builtsystems to ensure the best possible solution; and an indication of time scales to provide an oper...

  20. Design criteria and principles for criticality detection and alarm systems

    International Nuclear Information System (INIS)

    Delafield, H.J.; Clifton, J.J.

    1984-10-01

    The report gives design principles and criteria for criticality detection and alarm systems based on earlier work and revised in the light of more recent experience. In particular, account is taken of the developments which have taken place in the field of radiation detection and in the understanding of the different types of criticality excursion. General guidance is given on the principles to apply in deciding upon the need for a criticality system. The characteristics of a criticality incident are described in terms of the minimum incident of concern, and the radiation field. Criteria for the threshold of detection of a criticality incident are then derived and the methods of detection considered. The selection and siting of criticality detectors is discussed, and design principles are given for alarm systems. Finally, testing and post-alarm procedures are outlined, followed by a summary of the principal recommendations. The supporting Appendices include a discussion of reliability and a summary of radiation detector characteristics. (author)

  1. The Importance of Technical Reachback in the Adjudication of Radiation Alarms

    International Nuclear Information System (INIS)

    Buckley, W.M.; Allen, R.W.

    2009-01-01

    The large-scale deployment of radiation sensors at borders, ports-of-entry and other locations carries two disparate priorities: the reliable detection and identification of threat materials and the rapid characterization of non-threat materials comprised of naturally occurring radioactive materials (NORM) and legitimate radioactive materials in streams of commerce. These priorities are partially achieved through the technologies contained in the detection systems and the procedures developed for their operation. However, questions and ambiguities will occur. Without established capabilities and procedures for the operators of these detector systems to 'reach back' to trained spectroscopists and appropriate subject matter experts, the system will likely experience an unacceptable number of response operations and delays resolving alarms. Technical reachback operations need to be able to address the priorities discussed above while causing minimal perturbations in the flow of legitimate streams of commerce. Yet when necessary, reachback needs to be able to rapidly mobilize the appropriate response assets.

  2. The nature of alarm communication in Constrictotermes cyphergaster (Blattodea: Termitoidea: Termitidae: the integration of chemical and vibroacoustic signals

    Directory of Open Access Journals (Sweden)

    Paulo F. Cristaldo

    2015-12-01

    Full Text Available Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae, confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S-α-pinene and myrcene, along with a minor component, (E-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through

  3. Application control chart concepts of designing a pre-alarm system in the nuclear power plant control room

    International Nuclear Information System (INIS)

    Hwang, S.-L.; Lin, J.-T.; Liang, G.-F.; Yau, Y.-J.; Yenn, T.-C.; Hsu, C.-C.

    2008-01-01

    This study applied the concepts of the Shewhart control chart to design a pre-alarm system for the nuclear power plant control room. As a support in detecting faults, the pre-alarm system reminded the operators of a change in the system state in its early stages. Two pre-alarm types were designed to compare with the original system, and all participants were requested to monitor each simulated system under both normal and abnormal states. The tasks for the participants included shutting down the reactor, searching for procedures, monitoring system parameters and executing secondary tasks. In each trial, the task performance, mental workload and situation awareness (SA) of the participants were measured. Results indicated that participants had lower mental workload, but equal SA, when monitoring the system with either type of pre-alarm designs, and lower alarm frequency and higher secondary task performance were obtained with the pre-alarm design. Therefore, the pre-alarm system effectively assisted the operators in monitoring tasks

  4. On the Modeling of a MEMS Based Capacitive Accelerometer for Measurement of Tractor Seat Vibration

    Directory of Open Access Journals (Sweden)

    M. Alidoost

    2010-04-01

    Full Text Available Drivers of heavy vehicles often face with higher amplitudes of frequencies range between 1-80 Hz. Hence, this range of frequency results in temporary or even sometimes permanent damages to the health of drivers. Examples for these problems are damages to the vertebral column and early tiredness, which both reduce the driver’s performance significantly. One solution to this problem is to decrease the imposed vibration to the driver’s seat by developing an active seat system. These systems require an online measuring unit to sense vibrations transferred to the seat. The measuring unit can include a capacitive micro-accelerometer on the basis of MEMS which measure online vibrations on the seat. In this study, the mechanical behavior of a capacitive micro-accelerometer for the vibration range applied to a tractor seat has been simulated. The accelerometer is capable to measure step, impact and harmonic external excitations applied to the system. The results of the study indicate that, with increasing the applied voltage, the system sensitivity also increases, but the measuring range of vibrations decreases and vice versa. The modeled accelerometer, at damping ratio of 0.67 is capable to measure accelerations within the frequency range of lower than 130 Hz.

  5. An alarm filtering system for an automated process: a multiple-agent approach

    International Nuclear Information System (INIS)

    Khoualdi, Kamel

    1994-01-01

    Nowadays, the supervision process of industrial installations is more and more complex involving the automation of their control. A malfunction generates an avalanche of alarms. The operator, in charge of the supervision, must face the incident and execute right actions to recover a normal situation. Generally, he is drowned under the great number of alarms. Our aim, in the frame of our researches, is to perform an alarm filtering system for an automated metro line, to help the operator finding the main alarm responsible for the malfunction. Our works are divided into two parts, both dealing with study and development of an alarm filtering system but using two different approaches. The first part is developed in the frame of the SARA project (an operator assistance system for an automated metro line) which is an expert system prototype helping the operators of a command center. In this part, a centralized approach has been used representing the events with a single event graph and using a global procedure to perform diagnosis. This approach has itself shown its limits. In the second part of our works, we have considered the distributed artificial intelligence (DAI) techniques, and more especially the multi-agent approach. The multi-agent approach has been motivated by the natural distribution of the metro line equipment and by the fact that each equipment has its own local control and knowledge. Thus, each equipment has been considered as an autonomous agent. Through agents cooperation, the system is able to determine the main alarm and the faulty equipment responsible for the incident. A prototype, written in SPIRAL (a tool for knowledge-based system) is running on a workstation. This prototype has allowed the concretization and the validation of our multi-agent approach. (author) [fr

  6. rf duress alarms: market survey and preliminary characterization

    International Nuclear Information System (INIS)

    Draper, B.L.

    1979-05-01

    This report represents the first phase of the duress alarm studies. Presented here are the results of an extensive market survey and some preliminary observations on the effectiveness of many system components

  7. 40 CFR 267.34 - When must personnel have access to communication equipment or an alarm system?

    Science.gov (United States)

    2010-07-01

    ... to an internal alarm or emergency communication device, either directly or through visual or voice... communication equipment or an alarm system? 267.34 Section 267.34 Protection of Environment ENVIRONMENTAL... have access to communication equipment or an alarm system? (a) Whenever hazardous waste is being poured...

  8. Dynamic tire pressure sensor for measuring ground vibration.

    Science.gov (United States)

    Wang, Qi; McDaniel, James Gregory; Wang, Ming L

    2012-11-07

    This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application.

  9. Design Features and Capabilities of the First Materials Science Research Rack

    Science.gov (United States)

    Pettigrew, P. J.; Lehoczky, S. L.; Cobb, S. D.; Holloway, T.; Kitchens, L.

    2003-01-01

    The First Materials Science Research Rack (MSRR-1) aboard the International Space Station (ISS) will offer many unique capabilities and design features to facilitate a wide range of materials science investigations. The initial configuration of MSRR-1 will accommodate two independent Experiment Modules (EMS) and provide the capability for simultaneous on-orbit processing. The facility will provide the common subsystems and interfaces required for the operation of experiment hardware and accommodate telescience capabilities. MSRR1 will utilize an International Standard Payload Rack (ISPR) equipped with an Active Rack Isolation System (ARIS) for vibration isolation of the facility.

  10. Myocardial infarction false alarm: initial electrocardiogram and cardiac enzymes.

    Science.gov (United States)

    Gupta, Esha Das; Sakthiswary, Rajalingham

    2014-05-01

    The objectives of this study were to determine the incidence of a myocardial infarction "false alarm" and evaluate the efficacy of the initial electrocardiogram and cardiac enzymes in diagnosing myocardial infarction in Malaysia. We recruited patients who were admitted with suspected myocardial infarction from June to August 2008. The medical records of these patients were reviewed for the initial electrocardiogram, initial cardiac enzyme levels (creatinine kinase-MB and troponin T), and the final diagnosis upon discharge. The subjects were stratified into 2 groups: true myocardial infarction, and false alarm. 125 patients were enrolled in this study. Following admission and further evaluation, the diagnosis was revised from myocardial infarction to other medical conditions in 48 (38.4%) patients. The sensitivity and specificity of the initial ischemic electrocardiographic changes were 54.5% and 70.8%, respectively. Raised cardiac enzymes had a sensitivity of 44.3% and specificity of 95.8%. A significant proportion of patients in Malaysia are admitted with a false-alarm myocardial infarction. The efficacy of the electrocardiogram in diagnosing myocardial infarction in Malaysia was comparable to the findings of Western studies, but the cardiac enzymes had a much lower sensitivity.

  11. Vibration Analysis Of Automotive Structures Using Holographic Interferometry

    Science.gov (United States)

    Brown, G. M.; Wales, R. R.

    1983-10-01

    Since 1979, Ford Motor Company has been developing holographic interferometry to supplement more conventional test methods to measure vehicle component vibrations. An Apollo PHK-1 Double Pulse Holographic Laser System was employed to visualize a variety of complex vibration modes, primarily on current production and prototype powertrain components. Design improvements to reduce powertrain response to problem excitations have been deter-mined through pulsed laser holography, and have, in several cases, been put into production in Ford vehicles. Whole-field definition of vibration related deflections provide continuity of information missed by accelerometer/modal analysis techniaues. Certain opera-tional problems, common among pulsed ruby holographic lasers, have reauired ongoing hardware and electronics improvements to minimize system downtime. Real-time, time-averaged and stroboscopic C. W. laser holographic techniques are being developed at Ford to complement the double pulse capabilities and provide rapid identification of modal frequencies and nodal lines for analysis of powertrain structures. Methods for mounting and exciting powertrains to minimize rigid body motions are discussed. Work at Ford will continue toward development of C. W. holographic techniques to provide refined test methodology dedicated to noise and vibration diagnostics with particular emphasis on semi-automated methods for quantifying displacement and relative phase using high resolution digitized video and computers. Continued use of refined pulsed and CW laser holographic interferometry for the analysis of complex structure vibrations seems assured.

  12. Plutonium Finishing Plant (PFP) Criticality Alarm System Commercial Grade Item (CGI) Critical Characteristics

    International Nuclear Information System (INIS)

    WHITE, W.F.

    1999-01-01

    This document specifies the critical characteristics for Commercial Grade Items (CGI) procured for PFP's criticality alarm system as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item. PFP's Criticality Alarm System includes the nine criticality alarm system panels and their associated hardware. This includes all parts up to the first breaker in the electrical distribution system. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-003, ''Definition and Means of Maintaining the Criticality Detectors and Alarms Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.''

  13. Interevent times in a new alarm-based earthquake forecasting model

    Science.gov (United States)

    Talbi, Abdelhak; Nanjo, Kazuyoshi; Zhuang, Jiancang; Satake, Kenji; Hamdache, Mohamed

    2013-09-01

    This study introduces a new earthquake forecasting model that uses the moment ratio (MR) of the first to second order moments of earthquake interevent times as a precursory alarm index to forecast large earthquake events. This MR model is based on the idea that the MR is associated with anomalous long-term changes in background seismicity prior to large earthquake events. In a given region, the MR statistic is defined as the inverse of the index of dispersion or Fano factor, with MR values (or scores) providing a biased estimate of the relative regional frequency of background events, here termed the background fraction. To test the forecasting performance of this proposed MR model, a composite Japan-wide earthquake catalogue for the years between 679 and 2012 was compiled using the Japan Meteorological Agency catalogue for the period between 1923 and 2012, and the Utsu historical seismicity records between 679 and 1922. MR values were estimated by sampling interevent times from events with magnitude M ≥ 6 using an earthquake random sampling (ERS) algorithm developed during previous research. Three retrospective tests of M ≥ 7 target earthquakes were undertaken to evaluate the long-, intermediate- and short-term performance of MR forecasting, using mainly Molchan diagrams and optimal spatial maps obtained by minimizing forecasting error defined by miss and alarm rate addition. This testing indicates that the MR forecasting technique performs well at long-, intermediate- and short-term. The MR maps produced during long-term testing indicate significant alarm levels before 15 of the 18 shallow earthquakes within the testing region during the past two decades, with an alarm region covering about 20 per cent (alarm rate) of the testing region. The number of shallow events missed by forecasting was reduced by about 60 per cent after using the MR method instead of the relative intensity (RI) forecasting method. At short term, our model succeeded in forecasting the

  14. Assessment of predation risk through conspecific alarm odors by spiny lobsters

    Science.gov (United States)

    2009-01-01

    Strong “alarm odors” emanating from lethally injured conspecifics may indicate an imminent risk of predation to spiny lobsters. In laboratory trials,1 strong conspecific alarm odors elicited avoidance in Panulirus argus, a highly gregarious species that displays collective defense behavior, but not in Panulirus guttatus, a species that tends to aggregate when reproductive activity is high (spring) but not when it is low (late summer) and does not display collective defensive behavior. To reduce predation risk, however, lobsters may autotomize limbs, thus sustaining nonlethal injuries. I tested the response of these lobsters to scents emanating from intact, lethally-injured and non-lethally injured conspecifics. In P. argus, these scents elicited, respectively, attraction, avoidance and a random response, suggesting that, in P. argus, avoidance of conspecific alarm odors depends on their strength. In contrast, P. guttatus lobsters responded at random to scents of lethally injured conspecifics and showed a similar response to scents of intact and non-lethally injured conspecifics in the spring (attraction) and in the summer (random), reflecting the more cryptic defensive behavior of this species. Therefore, both species use conspecific alarm odors for risk-assessment, but each responds to these cues in the most effective way to reduce its risk of predation. PMID:19721871

  15. Westinghouse Hanford Company package testing capabilities

    International Nuclear Information System (INIS)

    Hummer, J.H.; Mercado, M.S.

    1993-07-01

    The Department of Energy's Hanford Site is a 1,450-km 2 (560-mi 2 ) installation located in southeastern Washington State. Established in 1943 as a plutonium production facility, Hanford's role has evolved into one of environmental restoration and remediation. Many of these environmental restoration and remediation activities involve transportation of radioactive/hazardous materials. Packagings used for the transportation of radioactive/hazardous materials must be capable of meeting certain normal transport and hypothetical accident performance criteria. Evaluations of performance to these criteria typically involve a combination of analysis and testing. Required tests may include the free drop, puncture, penetration, compression, thermal, heat, cold, vibration, water spray, water immersion, reduced pressure, and increased pressure tests. The purpose of this paper is to outline the Hanford capabilities for performing each of these tests

  16. Prioritizing alarms from sensor-based detection models in livestock production - A review on model performance and alarm reducing methods

    DEFF Research Database (Denmark)

    Dominiak, Katarina Sylow; Kristensen, Anders Ringgaard

    2017-01-01

    The objective of this review is to present, evaluate and discuss methods for reducing false alarms in sensor-based detection models developed for livestock production as described in the scientific literature. Papers included in this review are all peer-reviewed and present sensor-based detection...

  17. Levels of alarm thresholds of meningitis outbreaks in Hamadan Province, west of Iran.

    Science.gov (United States)

    Faryadres, Mohammad; Karami, Manoochehr; Moghimbeigi, Abbas; Esmailnasab, Nader; Pazhouhi, Khabat

    2015-01-01

    Few studies have focused on syndromic data to determine levels of alarm thresholds to detection of meningitis outbreaks. The purpose of this study was to determine threshold levels of meningitis outbreak in Hamadan Province, west of Iran. Data on both confirmed and suspected cases of meningitis (fever and neurological symptom) form 21 March 2010 to 20 March 2012 were used in Hamadan Province, Iran. Alarm threshold levels of meningitis outbreak were determined using four different methods including absolute values or standard method, relative increase, statistical cutoff points and upper control limit of exponentially weighted moving average (EWMA) algorithm. Among 723 reported cases, 41 were diagnosed to have meningitis. Standard level of alarm thresholds for meningitis outbreak was determined as incidence of 5/100000 persons. Increasing 1.5 to two times in reported cases of suspected meningitis per week was known as the threshold levels according to relative increase method. An occurrence four cases of suspected meningitis per week that equals to 90th percentile was chosen as alarm thresholds by statistical cut off point method. The corresponding value according to EWMA algorithm was 2.57 i.e. three cases. Policy makers and staff of syndromic surveillance systems are highly recommended to apply the above different methods to determine the levels of alarm threshold.

  18. Monitoring techniques and alarm procedures for CMS Services and Sites in WLCG

    International Nuclear Information System (INIS)

    Molina-Perez, J; Sciabà, A; Magini, N; Bonacorsi, D; Gutsche, O; Flix, J; Kreuzer, P; Fajardo, E; Boccali, T; Klute, M; Gomes, D; Kaselis, R; Butenas, I; Du, R; Wang, W

    2012-01-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS; the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.

  19. Monitoring techniques and alarm procedures for CMS services and sites in WLCG

    Energy Technology Data Exchange (ETDEWEB)

    Molina-Perez, J. [UC, San Diego; Bonacorsi, D. [Bologna U.; Gutsche, O. [Fermilab; Sciaba, A. [CERN; Flix, J. [Madrid, CIEMAT; Kreuzer, P. [CERN; Fajardo, E. [Andes U., Bogota; Boccali, T. [INFN, Pisa; Klute, M. [MIT; Gomes, D. [Rio de Janeiro State U.; Kaselis, R. [Vilnius U.; Du, R. [Beijing, Inst. High Energy Phys.; Magini, N. [CERN; Butenas, I. [Vilnius U.; Wang, W. [Beijing, Inst. High Energy Phys.

    2012-01-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS, the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.

  20. Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Provenza, Andrew J.

    2011-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

  1. Improvement and test of alarm cause tracking system for Kori nuclear power plant units 3 and 4

    International Nuclear Information System (INIS)

    Lee, Jung Woon; Park, Jae Chang; Lee, Jung Woon; Kim, Jung Taek; Lyu, Sung Pil; Kim, Eun Ju; Park, Joong Pal

    2003-05-01

    The proposed system, ACTS(Alarm Cause Tracking System), in the 1st development period(2002. 7 ∼ 2003. 6), tracks and displays the causes of alarms on-line from computerized logic diagrams. And the system highlights the specific procedures related the causes in the procedure of the alarm. But, some problems were found in ACTS on editing logic diagram and logic processing in realtime for 2000 logic diagrams. In 2nd development period, we improved the data structure of graphic information for logic diagram and changed function oriented programming to object oriented programming for logic elements. Also, the display of precedent alarms which introduce many following alarms is provided to avoid confusion from the followed nuisance alarms. And logic input signal generator was developed to test the ACTS which generates input signal in time sequence of events acquired from simulator or real plant

  2. Characterization and calibration of piezoelectric polymers: In situ measurements of body vibrations

    Science.gov (United States)

    Kappel, Marcel; Abel, Markus; Gerhard, Reimund

    2011-07-01

    Piezoelectric polymers are known for their flexibility in applications, mainly due to their bending ability, robustness, and variable sensor geometry. It is an optimal material for minimal-invasive investigations in vibrational systems, e.g., for wood, where acoustical impedance matches particularly well. Many applications may be imagined, e.g., monitoring of buildings, vehicles, machinery, alarm systems, such that our investigations may have a large impact on technology. Longitudinal piezoelectricity converts mechanical vibrations normal to the polymer-film plane into an electrical signal, and the respective piezoelectric coefficient needs to be carefully determined in dependence on the relevant material parameters. In order to evaluate efficiency and durability for piezopolymers, we use polyvinylidene fluoride and measure the piezoelectric coefficient with respect to static pressure, amplitude of the dynamically applied force, and long-term stability. A known problem is the slow relaxation of the material towards equilibrium, if the external pressure changes; here, we demonstrate how to counter this problem with careful calibration. Since our focus is on acoustical measurements, we determine accurately the frequency response curve - for acoustics probably the most important characteristic. Eventually, we show that our piezopolymer transducers can be used as a calibrated acoustical sensors for body vibration measurements on a wooden musical instrument, where it is important to perform minimal-invasive measurements. A comparison with the simultaneously recorded airborne sound yields important insight of the mechanism of sound radiation in comparison with the sound propagating in the material. This is especially important for transient signals, where not only the long-living eigenmodes contribute to the sound radiation. Our analyses support that piezopolymer sensors can be employed as a general tool for the determination of the internal dynamics of vibrating systems.

  3. Summary of work carried out in the field of N4 plant series alarm processing

    International Nuclear Information System (INIS)

    Joly, J.-J.; Maurin, S.

    1990-01-01

    This document summarizes work executed or under way regarding the processing of new N4 plant series alarms. A review of the specific objectives is provided as well as a general description of the processing of these alarms. A description of the systems and prototypes developed is then provided: -autonomous N4 alarm supplementary processing system, -logic check expert system, -functional design check expert system based on qualitative system modeling

  4. Process plant alarm diagnosis using synthesised fault tree knowledge

    International Nuclear Information System (INIS)

    Trenchard, A.J.

    1990-01-01

    The development of computer based tools, to assist process plant operators in their task of fault/alarm diagnosis, has received much attention over the last twenty five years. More recently, with the emergence of Artificial Intelligence (AI) technology, the research activity in this subject area has heightened. As a result, there are a great variety of fault diagnosis methodologies, using many different approaches to represent the fault propagation behaviour of process plant. These range in complexity from steady state quantitative models to more abstract definitions of the relationships between process alarms. Unfortunately, very few of the techniques have been tried and tested on process plant and even fewer have been judged to be commercial successes. One of the outstanding problems still remains the time and effort required to understand and model the fault propagation behaviour of each considered process. This thesis describes the development of an experimental knowledge based system (KBS) to diagnose process plant faults, as indicated by process variable alarms. In an attempt to minimise the modelling effort, the KBS has been designed to infer diagnoses using a fault tree representation of the process behaviour, generated using an existing fault tree synthesis package (FAULTFINDER). The process is described to FAULTFINDER as a configuration of unit models, derived from a standard model library or by tailoring existing models. The resultant alarm diagnosis methodology appears to work well for hard (non-rectifying) faults, but is likely to be less robust when attempting to diagnose intermittent faults and transient behaviour. The synthesised fault trees were found to contain the bulk of the information required for the diagnostic task, however, this needed to be augmented with extra information in certain circumstances. (author)

  5. Design of alarm systems in Swedish nuclear power plants; Utformning av larmsystem i svenska kaernkraftverk

    Energy Technology Data Exchange (ETDEWEB)

    Thunberg, Anna; Osvalder, Anna-Lisa (Dept. of Product and Production Development, Chalmers Univ. of Technology, Goeteborg (Sweden))

    2008-04-15

    Research within the area of improving alarm system design and performance has mainly focused on new alarm systems. However, smaller modernisations of legacy systems are more common in the Swedish nuclear industry than design of totally new systems. This imposes problems when the new system should function together with the old system. This project deals with the special concerns raised by modernisation projects. The objective of the project has been to increase the understanding of the relationship between the operator's performance and the design of the alarm system. Of major concern has been to consider the cognitive abilities of the operator, different operator roles and work situations, and varying need of information. The aim of the project has been to complement existing alarm design guidance and to develop user-centred alarm design concepts. Different case studies have been performed in several industry sectors (nuclear, oil refining, pulp and paper, aviation and medical care) to identify best practice. Several empirical studies have been performed within the nuclear area to investigate the operator's need of information, performance and workload in different operating modes. The aspect of teamwork has also been considered. The analyses show that the operator has different roles in different work situations which affect both the type of information needed and how the information is processed. In full power operation, the interaction between the operator and the alarm system is driven by internal factors and the operator tries to maintain high situation awareness by actively searching for information. The operator wants to optimise the process and need detailed information with possibilities to follow-up and get historical data. In disturbance management, the operator is more dependent on external information presented by the alarm system. The new compilation of alarm guidance is based on the operator's varying needs in different working

  6. Habituating alarming atmospheres

    DEFF Research Database (Denmark)

    Højlund, Marie

    This paper proposes embodied rhythmic sound habituation as a possible resource when designing contextualized technologies in critical atmospheres. The main contribution is collating the concept of rhythm as presented by Henri Lefebvre with the concept of sound habituation to help operationalize...... functionality for the staff, but are stressful for visitors and patients, as they are designed to demand attention even though they have no direct functional meaning to them. By introducing sounds from the ward, integrated in the furniture as simple sound sample triggers, KidKit invites children to become...... accustomed to the alarming sounds through rhythmic interaction in the waiting room, and bringing the furniture with them afterwards as a secure anchor, when entering the ward. This rhythmic habituation can enable the child to focus her attention on the meeting with the hospitalized relative....

  7. COUNTERMEASURE FOR MINIMIZE UNWANTED ALARM OF AUTOMATIC FIRE NOTIFICATION SYSTEM IN THE REPUBLIC OF KOREA

    Directory of Open Access Journals (Sweden)

    Hasung Kong

    2015-01-01

    Full Text Available In this article investigated the cause of error through survey to building officials for minimizing the unwanted alarm of automatic fire notification and suggested countermeasure for minimizing the unwanted alarm. The main cause of the unwanted alarm is defective fire detector, interlocking with automatic fire detection system, lack in fire safety warden’s ability, worn-out fire detect receiving system. The countermeasure for minimizing unwanted alarm is firstly, tightening up the standard of model approval, Secondly, interlocking with cross-section circuit method fire extinguishing system or realizing automatic fire notification system interlocking with home network, thirdly, tightening up licensing examination of fire safety warden, lastly, it suggested term of use rule of fire detect receiving system.

  8. [Occupational standing vibration rate and vibrational diseases].

    Science.gov (United States)

    Karnaukh, N G; Vyshchipan, V F; Haumenko, B S

    2003-12-01

    Occupational standing vibration rate is proposed in evaluating a degree of impairment of an organism activity. It will allow more widely to introduce specification of quality and quantity in assessment of the development of vibrational disease. According out-patient and inpatient obtained data we have established criterial values of functional changes in accordance with accumulated occupational standing vibration rate. The nomogram was worked out for defining a risk of the development of vibrational disease in mine workers. This nomogram more objectively can help in diagnostics of the disease.

  9. Active and passive vibration isolation in piezoelectric phononic rods with external voltage excitation

    Directory of Open Access Journals (Sweden)

    Qicheng Zhang

    2017-05-01

    Full Text Available Active piezoelectric materials are applied to one-dimensional phononic crystals, for the control of longitudinal vibration propagation both in active and passive modes. Based on the electromechanical coupling between the acoustical vibration and electric field, the electromechanical equivalent method is taken to theoretically predict the transmission spectrum of the longitudinal vibration. It is shown that the phononic rod can suppress the vibration efficiently at the frequencies of interest, by actively optimizing the motions of piezoelectric elements. In an illustrated phononic rod of 11.2cm long, active tunable isolations of more than 20dB at low frequencies (500Hz-14kHz are generated by controlling the excitation voltages of piezoelectric elements. Meanwhile, passive fixed isolation at high frequencies (14k-63kHz are presented by its periodicity characteristics. Finite element simulations and vibration experiments on the rod demonstrate the effectiveness of the approach in terms of its vibration isolation capabilities and tunable characteristics. This phononic rod can be manufactured easily and provides numerous potential applications in designing isolation mounts and platforms.

  10. BVI induced vibration and noise alleviation by active and passive approaches

    Science.gov (United States)

    Liu, Li

    This dissertation describes the development of a comprehensive aeroelastic/aeroacoustic simulation capability for the modeling of vibration and noise in rotorcraft induced by blade-vortex interaction (BVI). Subsequently this capability is applied to study vibration and noise reduction, using active and passive control approaches. The active approach employed is the actively controlled partial span trailing edge flaps (ACF), implemented in single and dual, servo and plain flap configurations. The passive approach is based on varying the sweep and anhedral on the tip of the rotor. Two different modern helicopters are chosen as the baseline for the implementation of ACF approach, one resembling a four-bladed MBB BO-105 hingeless rotor and the other similar to a five-bladed MD-900 bearingless rotor. The structural model is based on a finite element approach capable of simulating composite helicopter blades with swept tips, and representing multiple load paths at the blade root which is a characteristic of bearingless rotors. An unsteady compressible aerodynamic model based on a rational function approximation (RFA) approach is combined with a free wake analysis which has been enhanced by improving the wake analysis resolution and modeling a dual vortex structure. These enhancements are important for capturing BVI effects. A method for predicting compressible unsteady blade surface pressure distribution on rotor blades has been developed, which is required by the acoustic analysis. A modified version of helicopter noise code WOPWOP with provisions for blade flexibility has been combined with the aeroelastic analysis to predict the BVI noise. Several variants of the higher harmonic control (HHC) algorithm have been applied for the active noise control, as well as the simultaneous vibration and noise control. Active control of BVI noise is accomplished using feedback from an onboard microphone. The simulation has been extensively validated against experimental data and

  11. Plant experience with an expert system for alarm diagnosis

    International Nuclear Information System (INIS)

    Gimmy, K.L.

    1986-01-01

    An expert system called Diagnosis of Multiple Alarms (DMA) is in routine use at four nuclear reactors operated by the DuPont Company. The system is wired to plant alarm annunciators and does event-tree analysis to see if a pattern exists. Any diagnosis is displayed to the plant operator and the corrective procedure to be followed is also identified. The display is automatically superseded if a higher priority diagnosis is made. The system is integrated with operator training and procedures. Operating results have been positive. DMA has diagnosed several hard-to-locate small leaks. There have been some false diagnosis, and realistic plant environments must be considered in such expert systems. 2 refs., 5 figs

  12. Nitric Acid Revamp and Upgrading of the Alarm & Protection Safety System at Petrokemija, Croatia

    Directory of Open Access Journals (Sweden)

    Hoško, I.

    2012-04-01

    Full Text Available Every industrial production, particularly chemical processing, demands special attention in conducting the technological process with regard to the security requirements. For this reason, production processes should be continuously monitored by means of control and alarm safety instrumented systems. In the production of nitric acid at Petrokemija d. d., the original alarm safety system was designed as a combination of an electrical relay safety system and transistorized alarm module system. In order to increase safety requirements and modernize the technological process of nitric acid production, revamping and upgrading of the existing alarm safety system was initiated with a new microprocessor system. The newly derived alarm safety system, Simatic PCS 7, links the function of "classically" distributed control (DCS and logical systems in a common hardware and software platform with integrated engineering tools and operator interface to meet the minimum safety standards with safety integrity level 2 (SIL2 up to level 3 (SIL3, according to IEC 61508 and IEC 61511. This professional paper demonstrates the methodology of upgrading the logic of the alarm safety system in the production of nitric acid in the form of a logical diagram, which was the basis for a further step in its design and construction. Based on the mentioned logical diagram and defined security requirements, the project was implemented in three phases: analysis and testing, installation of the safety equipment and system, and commissioning. Developed also was a verification system of all safety conditions, which could be applied to other facilities for production of nitric acid. With the revamped and upgraded interlock alarm safety system, a new and improved safety boundary in the production of nitric acid was set, which created the foundation for further improvement of the production process in terms of improved analysis.

  13. A nanogenerator as a self-powered sensor for measuring the vibration spectrum of a drum membrane

    Science.gov (United States)

    Yu, Aifang; Zhao, Yong; Jiang, Peng; Wang, Zhong Lin

    2013-02-01

    A nanogenerator (NG) is a device that converts vibration energy into electricity. Here, a flexible, small size and lightweight NG is successfully demonstrated as an active sensor for detecting the vibration spectrum of a drum membrane without the use of an external power source. The output current/voltage signal of the NG is a direct measure of the strain of the local vibrating drum membrane that contains rich informational content, such as, notably, the vibration frequency, vibration speed and vibration amplitude. In comparison to the laser vibrometer, which is excessively complex and expensive, this kind of small and low cost sensor based on an NG is also capable of detecting the local vibration frequency of a drum membrane accurately. A spatial arrangement of the NGs on the membrane can provide position-dependent vibration information on the surface. The measured frequency spectrum can be understood on the basis of the theoretically calculated vibration modes. This work expands the application of NGs and reveals the potential for developing sound wave detection, environmental/infrastructure monitoring and many more applications.

  14. 29 CFR 1910.165 - Employee alarm systems.

    Science.gov (United States)

    2010-07-01

    ... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Fire Protection Other Fire Protection Systems § 1910.165 Employee... notification to assigned personnel whenever a deficiency exists in the system. The employer shall assure that... 29 Labor 5 2010-07-01 2010-07-01 false Employee alarm systems. 1910.165 Section 1910.165 Labor...

  15. An Undergraduate Experiment in Alarm System Design.

    Science.gov (United States)

    Martini, R. A.; And Others

    1988-01-01

    Describes an experiment involving data acquisition by a computer, digital signal transmission from the computer to a digital logic circuit and signal interpretation by this circuit. The system is being used at the Illinois Institute of Technology. Discusses the fundamental concepts involved. Demonstrates the alarm experiment as it is used in…

  16. An innovative MRE absorber with double natural frequencies for wide frequency bandwidth vibration absorption

    International Nuclear Information System (INIS)

    Sun, Shuaishuai; Yang, Jian; Li, Weihua; Alici, Gursel; Deng, Huaxia; Du, Haiping; Yan, Tianhong

    2016-01-01

    A new design of adaptive tuned vibration absorber was proposed in this study for vibration reduction. The innovation of the new absorber is the adoption of the eccentric mass on the top of the multilayered magnetorheological elastomer (MRE) structure so that this proposed absorber has two vibration modes: one in the torsional direction and the other in translational direction. This property enables the absorber to expand its effective bandwidth and to be more capable of reducing the vibrations especially dealing with those vibrations with multi-frequencies. The innovative MRE absorber was designed and tested on a horizontal vibration table. The test results illustrate that the MRE absorber realized double natural frequencies, both of which are controllable. Inertia’s influence on the dynamic behavior of the absorber is also investigated in order to guide the design of the innovative MRE absorber. Additionally, the experimentally obtained natural frequencies coincide with the theoretical data, which sufficiently verifies the feasibility of this new design. The last part in terms of the vibration absorption ability also proves that both of these two natural frequencies play a great role in absorbing vibration energy. (paper)

  17. Sequence and batch language programs and alarm-related ``C`` programs for the 242-A MCS. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Berger, J.F.

    1995-03-01

    A Distributive Process Control system was purchased by Project B-534, ``242-A Evaporator/Crystallizer Upgrades``. This control system, called the Monitor and Control System (MCS), was installed in the 242-A Evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict the overall process. To do this, WTSE developed a second alarm scheme which uses special programs, annunciator keys, and process graphics. The special programs are written in two languages; Sequence and Batch Language (SABL), and ``C`` language. The WTSE-developed alarm scheme works as described below: SABL relates signals and alarms to the annunciator keys, called SKID keys. When an alarm occurs, a SABL program causes a SKID key to flash, and if the alarm is of yellow or white priority then a ``C`` program turns on an audible horn (the D/3 system uses a different audible horn for the red priority alarms). The horn and flashing key draws the attention of the operator.

  18. Electromagnetic Vibration Energy Harvesting Devices Architectures, Design, Modeling and Optimization

    CERN Document Server

    Spreemann, Dirk

    2012-01-01

    Electromagnetic vibration transducers are seen as an effective way of harvesting ambient energy for the supply of sensor monitoring systems. Different electromagnetic coupling architectures have been employed but no comprehensive comparison with respect to their output performance has been carried out up to now. Electromagnetic Vibration Energy Harvesting Devices introduces an optimization approach which is applied to determine optimal dimensions of the components (magnet, coil and back iron). Eight different commonly applied coupling architectures are investigated. The results show that correct dimensions are of great significance for maximizing the efficiency of the energy conversion. A comparison yields the architectures with the best output performance capability which should be preferably employed in applications. A prototype development is used to demonstrate how the optimization calculations can be integrated into the design–flow. Electromagnetic Vibration Energy Harvesting Devices targets the design...

  19. Changes in 900 MW PWR alarm processing policy

    Energy Technology Data Exchange (ETDEWEB)

    Pont, M [Electricite de France, Generation and Transmission, Nuclear Power Plant Operations, Paris (France)

    1997-09-01

    Following a brief description of the current 900 MW PWR alarm processing system, this document presents the feasibility study carried out within the scope of the Instrumentation and Control Refurbishment project (R2C). (author). 4 figs, tabs.

  20. Changes in 900 MW PWR alarm processing policy

    International Nuclear Information System (INIS)

    Pont, M.

    1997-01-01

    Following a brief description of the current 900 MW PWR alarm processing system, this document presents the feasibility study carried out within the scope of the Instrumentation and Control Refurbishment project (R2C). (author). 4 figs, tabs

  1. A basic design of alarm system for the future nuclear power plants in Korea

    International Nuclear Information System (INIS)

    Lee, Cheol-Kwon; Hur, Seop; Shin, Jae-Hwal; Koo, In-Soo; Park, Jong-Kyun

    1997-01-01

    The design of an advanced alarm system is under way to apply to the new MMIS for the future nuclear power plants in Korea. Based on the alarm system design bases we established the design requirements and are now refining them with the results of evaluation through the prototype. To realize the advanced system new algorithms for alarm processing and display are implemented and various new devices are examined. The evaluation for the design is performed in accordance with the verification and validation plans and through the prototype. (author). 7 refs, 2 figs

  2. Recovering Intrinsic Fragmental Vibrations Using the Generalized Subsystem Vibrational Analysis.

    Science.gov (United States)

    Tao, Yunwen; Tian, Chuan; Verma, Niraj; Zou, Wenli; Wang, Chao; Cremer, Dieter; Kraka, Elfi

    2018-05-08

    Normal vibrational modes are generally delocalized over the molecular system, which makes it difficult to assign certain vibrations to specific fragments or functional groups. We introduce a new approach, the Generalized Subsystem Vibrational Analysis (GSVA), to extract the intrinsic fragmental vibrations of any fragment/subsystem from the whole system via the evaluation of the corresponding effective Hessian matrix. The retention of the curvature information with regard to the potential energy surface for the effective Hessian matrix endows our approach with a concrete physical basis and enables the normal vibrational modes of different molecular systems to be legitimately comparable. Furthermore, the intrinsic fragmental vibrations act as a new link between the Konkoli-Cremer local vibrational modes and the normal vibrational modes.

  3. Central display system of figures in fire alarm

    International Nuclear Information System (INIS)

    Fang Shaohong; Zhu Zicheng; Zhu Liqun; Ren Yi; Yu Hongmei; Du Chengbao; Xie Guoxue

    1997-01-01

    A new type of 'central display system of figures in fire alarm' includes two parts: (1) software package of drawing picture; (2) real time processing and operate system (POS). Main function of the software package is to draw floor plane figures, fire-fighting facility signs and room numbers; and then all pictures are used in POS. Main functions of POS are to process fire alarm, faults and activation of fire fighting control facility, save and print reports, look over floor plane figures, look over concrete condition of fire fighting facilities, and to show appropriate prompt according to different case. This system realizes many functions, such as, control with mouse, operation with push-button, menu operation interface, flip windows to prompt, and chinese character. It have won acclaim for its amazing interface, its convenience to operate, its reliability and flexibility

  4. PROLOG language application for alarm system realization in accelerator control

    International Nuclear Information System (INIS)

    Frolov, I.; Vaguine, A.; Abe, I.; Nakahara, K.; Furukawa, K.; Kamikubota, N.

    1994-01-01

    Such PROLOG features as backtracking, matching and recursive data representation are powerful tools for ALARM system realization. Although the main idea is the possibility to describe some technical system in recursive form, backtracking and matching are ideal for processing recursive data structures. This paper represents a technique which would allow PROLOG language application for ALARM system realization using an example of the KEK LINAC magnet system. The technique is based on an object-oriented internal data representation in terms of objects, properties, relations and knowledge conception. In addition, each property value is characterized by a typical 'time life'. (author)

  5. Experimental Investigation on the Material Removal of the Ultrasonic Vibration Assisted Abrasive Water Jet Machining Ceramics

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2017-01-01

    Full Text Available The ultrasonic vibration activated in the abrasive water jet nozzle is used to enhance the capability of the abrasive water jet machinery. The experiment devices of the ultrasonic vibration assisted abrasive water jet are established; they are composed of the ultrasonic vibration producing device, the abrasive supplying device, the abrasive water jet nozzle, the water jet intensifier pump, and so on. And the effect of process parameters such as the vibration amplitude, the system working pressure, the stand-off, and the abrasive diameter on the ceramics material removal is studied. The experimental result indicates that the depth and the volume removal are increased when the ultrasonic vibration is added on abrasive water jet. With the increase of vibration amplitude, the depth and the volume of material removal are also increased. The other parameters of the ultrasonic vibration assisted abrasive water jet also have an important role in the improvement of ceramic material erosion efficiency.

  6. COUNTERMEASURE FOR MINIMIZE UNWANTED ALARM OF AUTOMATIC FIRE NOTIFICATION SYSTEM IN THE REPUBLIC OF KOREA

    Directory of Open Access Journals (Sweden)

    Hasung Kong

    2015-01-01

    Full Text Available In this article investigated the cause of error through survey to building officials for minimizing the unwanted alarm of automatic fire notification and suggested countermeasure for minimizing the unwanted alarm. The main cause of the unwanted alarm is defective fire detector, interlocking with automatic fire detection system, lack in fire safety warden’s ability, worn-out fire detect receiving system. The countermeasure for minimizing unwanted alarm is firstly, tightening up the standard of model approval, Secondly, interlocking with cross-section circuit method fire extinguishing system or realizing automatic fire notification system interlocking with home network, thirdly, tightening up licensing examination of fire safety warden, lastly, it suggested term of use rule of fire detect receiving system. 

  7. Communication interface of computerized automatic fire alarm system

    International Nuclear Information System (INIS)

    Yu Hongmei; Zhu Liqun; Fang Shaohong; Du Chengbao

    1997-01-01

    The problems of communication between multiple single-chip computers and microcomputer have been solved by the way of hardware and software. The automatic fire alarm system is realized by using the serial port both on single-chip computer and microcomputer

  8. Ecological alarm system for Itaipu

    Energy Technology Data Exchange (ETDEWEB)

    Faehser, L.

    1984-05-01

    At Itaipu, on the Rio Parana, Brazil and Paraguay are constructing the world's largest hydro-electric power plant with a capacity seven times as high as that of Assuan. An information system is intended to give fair warning in case of threatening ecological conditions. The computer-supported alarm system had four objectives: 1. presentation of the present ecological situation; 2. evaluation of the ecological risks; 3. warning about ecological deficits; 4. suggestions for establishing ecological stability. In a first step the available inventory data concerning soil, topography, vegetation and water were evaluated by expert groups according to their risk grade (0-4) and ecological weight (1-10). The product of these evaluations indicates the ecological deficit (0-40). At a threshold value of 30, the information system automatically signals ecological alarm and locates the centre of danger via computer-plotted maps and tables. The necessary data are supplied periodically by selected measurement stations. Quantification of ecological facts enables the persons who are responsible for decisions at Itaipu to recognize, avoid, or diminish elements of danger even if they have little or no ecological knowledge. The file of data that has been compiled so far should be extended parallel with the development in the Itaipu area. With the help of factor analysis connections of cause and effect can be detected in this extremely complex reservoir system which has hardly been explored yet.

  9. Alarming signs and symptoms in febrile children in primary care: an observational cohort study in The Netherlands.

    Directory of Open Access Journals (Sweden)

    Gijs Elshout

    Full Text Available CONTEXT: Febrile children in primary care have a low risk for serious infection. Although several alarming signs and symptoms are proposed to have predictive value for serious infections, most are based on research in secondary care. The frequency of alarming signs/symptoms has not been established in primary care; however, in this setting differences in occurrence may influence their predictive value for serious infections. OBJECTIVE: To determine the frequency of alarming signs/symptoms in febrile children in primary care. DESIGN: Observational cohort study. Clinical information was registered in a semi-structured way and manually recoded. SETTING: General practitioners' out-of-hours service. SUBJECTS: Face-to-face patient contacts concerning children (aged ≤16 years with fever were eligible for inclusion. MAIN OUTCOME MEASURES: Frequency of 18 alarming signs and symptoms as reported in the literature. RESULTS: A total of 10,476 patient contacts were included. The frequency of alarming signs/symptoms ranged from n = 1 (ABC instability; 40°C as reported by the parents; 12.9% to 8,647 contacts (parental concern; 82.5%. CONCLUSION: Although the prevalence of specific alarming signs/symptoms is low in primary care, ≥50% of children have one or more alarming signs/symptoms. There is a need to determine the predictive value of alarming signs/symptoms not only for serious infections in primary care, but as well for increased risk of a complicated course of the illness.

  10. On-line vibration monitoring for submerged vertical shaft pumps: Final report

    International Nuclear Information System (INIS)

    Walter, T.J.; Marchione, M.M.

    1988-03-01

    The overall goal of this project was to extend to vertical pumps the capability that presently exists to monitor and diagnose vibration problems in horizontal pumps. Specific objectives included the development of analytical techniques to interpret vibration measurements, the verification of these techniqeus by in-plant tests, and the development of recommendations for procuring submergible vibration sensors. A concurrent analytical and experimental approach was used to accomplish these objectives. Rotordynamic analyses of selected pumps were accomplished, and each pump was instrumented and monitored for extended periods of time. The models were used to determine important frequencies and optimum sensor locations and to predict the effect that wear, imbalance, misalighment, and other mechanical changes would have on measured vibration. The predictive ability of the models was confirmed by making changes to instrumented pumps and observing actual changes in pump vibration. Simplified guidelines have been developed to assist the interested user to develop a computer model that realistically predicts the rotordynamic performance of the installed pump. Based on the work accomplished, typical sensor locations have been established. Experience gained in application of commercially available submergible sensors is also related. 11 refs., 11 figs

  11. Fabrication and evaluation of polymeric early-warning fire-alarm devices. [combustion products

    Science.gov (United States)

    Senturia, S. D.

    1975-01-01

    The electrical resistivities were investigated of some polymers known to be enhanced by the presence of certain gases. This was done to make a device capable of providing early warning to fire through its response with the gases produced in the early phases of combustion. Eight polymers were investigated: poly(phenyl acetylene), poly(p-aminophenyl acetylene), poly(p-nitrophenyl acetylene), poly(p-formamidophenyl acetylene), poly(ethynyl ferrocene), poly(ethynyl carborane), poly(ethynyl pyridine), and the polymer made from 1,2,3,6 tetramethyl pyridazine. A total of 40 usable thin-film sandwich devices and a total of 70 usable interdigitated-electrode lock-and-key devices were fabricated. The sandwich devices were used for measurements of contact linearity, polymer conductivity, and polymer dielectric constant. The lock-and-key devices were used to determine the response of the polymers to a spectrum of gases that included ammonia, carbon nonoxide, carbon dioxide, sulfur dioxide, ethylene, acrolein, water vapor, and normal laboratory air. Strongest responses were to water vapor, ammonia, and acrolein, and depending on the polymer, weaker responses to carbon dioxide, sulfur dioxide, and carbon monoxide were observed. A quantitative theory of device operation, capable of accounting for observed device leakage current and sensitivity, was developed. A prototype detection/alarm system was designed and built for use in demonstrating sensor performance.

  12. Effect of shelf aging on vibration transmissibility of anti-vibration gloves

    Science.gov (United States)

    SHIBATA, Nobuyuki

    2017-01-01

    Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by environmental conditions such as temperature, humidity, and photo-irradiation, which cause material degradation and aging. This study focused on the influence of shelf aging on the vibration attenuation performance of air-packaged anti-vibration gloves following 2 yr of shelf aging. Effects of shelf aging on the vibration attenuation performance of anti-vibration gloves were examined according to the Japan industrial standard JIS T8114 test protocol. The findings indicate that shelf aging induces the reduction of vibration attenuation performance in air-packaged anti-vibration gloves. PMID:28978817

  13. Vibration measurement on composite material with embedded optical fiber based on phase-OTDR

    Science.gov (United States)

    Franciscangelis, C.; Margulis, W.; Floridia, C.; Rosolem, J. B.; Salgado, F. C.; Nyman, T.; Petersson, M.; Hallander, P.; Hällstrom, S.; Söderquist, I.; Fruett, F.

    2017-04-01

    Distributed sensors based on phase-optical time-domain reflectometry (phase-OTDR) are suitable for aircraft health monitoring due to electromagnetic interference immunity, small dimensions, low weight and flexibility. These features allow the fiber embedment into aircraft structures in a nearly non-intrusive way to measure vibrations along its length. The capability of measuring vibrations on avionics structures is of interest for what concerns the study of material fatigue or the occurrence of undesirable phenomena like flutter. In this work, we employed the phase-OTDR technique to measure vibrations ranging from some dozens of Hz to kHz in two layers of composite material board with embedded polyimide coating 0.24 numerical aperture single-mode optical fiber.

  14. Influence of conspecific and heterospecific aggregation cues and alarm odors on shelter choice by syntopic spiny lobsters.

    Science.gov (United States)

    Briones-Fourzán, Patricia; Ramírez-Zaldívar, Eunice; Lozano-Alvarez, Enrique

    2008-10-01

    In spiny lobsters, conspecific scents ("aggregation cues") may mediate gregarious diurnal sheltering, but scents from injured conspecifics ("alarm odors") may elicit avoidance behavior. In laboratory experiments, individuals of two coexisting species, Panulirus guttatus (a reef-obligate) and P. argus (a temporary reef-dweller), significantly chose shelters emanating conspecific aggregation cues and responded randomly to shelters emanating heterospecific aggregation cues. However, despite evidence that the two species perceived each other's alarm odors to a similar extent, P. guttatus responded randomly to shelters emanating either conspecific or heterospecific alarm odors, whereas P. argus significantly avoided both. This differential influence of alarm odors likely reflects interspecific differences in life history, sociality, and behavior. The less social, reef-obligate P. guttatus lobsters forage close to their reef dens, into which they retract deeply upon perception of risk. This cryptic behavior may offset the need to avoid conspecific (and heterospecific) alarm odors. In contrast, avoidance of conspecific alarm odors by P. argus is consistent with its ontogenetic habitat shifts and greater sociality. Furthermore, because reef-dwelling P. argus lobsters forage across open areas away from the reef, an ability to avoid alarm odors from P. guttatus upon returning to their reef dens may increase their fitness.

  15. "Alarm-corrected" ergonomic armrest use could improve learning curves of novices on robotic simulator.

    Science.gov (United States)

    Yang, Kun; Perez, Manuela; Hossu, Gabriela; Hubert, Nicolas; Perrenot, Cyril; Hubert, Jacques

    2017-01-01

    In robotic surgery, the professional ergonomic habit of using an armrest reduces operator fatigue and increases the precision of motion. We designed and validated a pressure surveillance system (PSS) based on force sensors to investigate armrest use. The objective was to evaluate whether adding an alarm to the PSS system could shorten ergonomic training and improve performance. Twenty robot and simulator-naïve participants were recruited and randomized in two groups (A and B). The PSS was installed on a robotic simulator, the dV-Trainer, to detect contact with the armrest. The Group A members completed three tasks on the dV-Trainer without the alarm, making 15 attempts at each task. The Group B members practiced the first two tasks with the alarm and then completed the final tasks without the alarm. The simulator provided an overall score reflecting the trainees' performance. We used the new concept of an "armrest load" score to describe the ergonomic habit of using the armrest. Group B had a significantly higher performance score (p ergonomic errors and accelerated professional ergonomic habit acquisition. The combination of the PSS and alarm is effective in significantly shortening the learning curve in the robotic training process.

  16. Bridge Condition Assessment based on Vibration Responses of Passenger Vehicle

    International Nuclear Information System (INIS)

    Miyamoto, Ayaho; Yabe, Akito

    2011-01-01

    In this paper, we propose a new method of assessing the condition of existing short- and medium-span reinforced/prestressed concrete bridges based on vibration monitoring data obtained from a public bus. This paper not only describes details of a prototype monitoring system that uses information technology and sensors capable of providing more accurate knowledge of bridge performance than conventional ways but also shows a few specific examples of bridge condition assessment based on vehicle vibrations measured by using an in-service public bus equipped with vibration measurement instrumentation. This paper also describes a sensitivity analysis of deteriorating bridges based on simulation of the acceleration response of buses conducted by the 'substructure method' employing a finite element model to verify the above bridge performance results. The main conclusions obtained in this study can be summarized as follows: (1) Because the vibration responses of passenger vehicles, such as buses, have a good linear relationship with the vibration responses of the target bridges, the proposed system can be used as a practical monitoring system for bridge condition assessment. (2) The results of sensitivity analysis performed by the substructure method show that bus vibration responses are useful for evaluating target bridge performance. (3) The proposed method was applied to a network of real bridges in a local area to evaluate its effectiveness. The results indicate that the proposed method can be used to prioritize the repair/strengthening works of existing bridges based on various vibration information in order to help bridge administrators establish rational maintenance strategies.

  17. System and method for damping vibration in a drill string

    Science.gov (United States)

    Wassell, Mark Ellsworth; Turner, William Evans; Burgess, Daniel E; Perry, Carl Allison

    2014-03-04

    A system for damping vibration in a drill string can include a valve assembly having a supply of a fluid, a first member, and a second member capable of moving in relation to first member in response to vibration of the drill bit. The first and second members define a first and a second chamber for holding the fluid. Fluid can flow between the first and second chambers in response to the movement of the second member in relation to the first member. The valve assembly can also include a coil or a valve for varying a resistance of the fluid to flow between the first and second chambers.

  18. Associations between reporting of cancer alarm symptoms and socioeconomic and demographic determinants

    DEFF Research Database (Denmark)

    Svendsen, Rikke Pilsgaard; Paulsen, Maja Skov; Larsen, Pia Veldt

    2012-01-01

    ABSTRACT: BACKGROUND: Reporting of symptoms which may signal cancer is the first step in the diagnostic pathway of cancer diseases. Cancer alarm symptoms are common in the general population. Public awareness and knowledge of cancer symptoms are sparse, however, and many people do not seek medical...... help when having possible cancer symptoms. As social inequality is associated with cancer knowledge, cancer awareness, and information-seeking, our hypothesis is that social inequality may also exist in the general population with respect to reporting of cancer alarm symptoms. The aim of this study...... was to investigate possible associations between socioeconomic and demographic determinants and reporting of common cancer alarm symptoms. METHODS: A cross-sectional questionnaire survey was performed based on a stratified sample of the Danish general population. A total of 13 777 randomly selected persons aged 20...

  19. The study of system function analysis method for success path alarm design

    International Nuclear Information System (INIS)

    Kang, S. K.; Shin, Y. C.

    1999-01-01

    The key benefit to the common use of the critical function approach for safety and mission functions is that monitoring methods expected to be used by operaotrs during emergency condition are used continuously during normal operation. For each critical safety function there exists two or more success paths. Information Processing System monitors the availability, operation state and performance of the critical function success paths. In this paper, We have studied System Function Analysis(SFA) for the design of Success Path Alarm(SPA) for applying in KNGR. In here, we thought that SFA will help the design of SPA. The SFA can be applicable to the design of SPA according to NUREG-0711, also can induce the algorithm for alarm of system, train and flow path. We present a method of system function analysis for designing Success Path Alarm

  20. ARC Code TI: Optimal Alarm System Design and Implementation

    Data.gov (United States)

    National Aeronautics and Space Administration — An optimal alarm system can robustly predict a level-crossing event that is specified over a fixed prediction horizon. The code contained in this packages provides...

  1. Fluidelastic vibration of cylinder arrays in axial and cross flow--state of the art

    International Nuclear Information System (INIS)

    Paidoussis, M.P.

    1981-01-01

    A critical assessment of the state of the art for flow-induced vibrations of cylinder arrays in cross and axial flow is presented. An historical review highlights the contributions which advanced understanding of the flow-induced vibration phenomena involved and/or predictive ability. In the case of axial-flow-induced vibration, the absence of separated flow regions has contributed towards the development of analytical predictive tools. The designer may predict the onset of fluidelastic instabilities, which generally occur at very high flow velocities, with greater confidence. In contrast, in the case of cross-flow-induced vibration, the complexity of the flow has encouraged more heuristic approaches to be adopted. The state of the art in this case is discussed with the aid of a new classification of the flow-induced vibration phenomena involved, to unify and clarify the contradictory claims facing the designer. It is concluded that, although the physical understanding of cross-flow-induced vibration phenomena is not good, useful design guidelines do exist. These are capable of predicting vibration characteristics to within a factor of 2 to 10. A comprehensive bibliography is included. 115 refs

  2. Vibration reduction at the engine-pumps assembly of the main moderator system

    International Nuclear Information System (INIS)

    Holostencu, Adriana; Dinu, Marius

    2005-01-01

    Problem of decreasing vibrations in the main moderator motor at Cernavoda NPP - Unit 1 is presented. The moderator pumps are of centrifugal, vertical, single stage and double suction type. Each pump is provided with a main motor (690 Kw, 50 Hz, 6 KV) capable of full rotative speed and a secondary motor, also known as 'pony motor' (15 Kw, 50 Hz, 380 V) capable of a quarter of the full speed. At starting-commissioning stage of Cernavoda NPP, the vibration level in the moderator pump - motor assembly had an average value of 6 mm/s with spurious peaks up to 8 mm/s. It has to be mentioned that operation with a high vibration level may lead to: - a premature wear of the motor bearings; - extra stresses and fatigue in the material of pump and associated pipes. In order to maintain vibration speed to the design limit, the NPP personnel have started investigations since 1997. The main activities were: - verification of the vibration measuring loops; - checking the torque of the bolts that hold the motor's case; - measuring the start-up and nominal currents of the motors in order to determine any phase unbalance; - adjusting the spring hangers from the pumps discharge with simultaneous monitoring of the motor vibration level; - installation of rubber pads in the gap between the motor lugs and the existing seismic supports. None of these actions revealed deviations from the installation requirements or operating parameters. In 1999, a contract with EUROTEST S. A and Stevenson was signed, in order to find a solution to reduce the vibration level. The EUROTEST/ Stevenson action plan contains de following main activities: 1. Creating a calculus model of the moderator system, based on the design drawings provided by Cernavoda NPP; 2. Preparing and performing the vibration measurements in various points of the system; 3. Analyzing the measurements results; 4. Calibrating the calculus model created in step 1, according with the field measurements; 5. Propose a solution to reduce

  3. Dosimetric properties of the pocket alarm dosimeter type Graetz TDW 10/20

    International Nuclear Information System (INIS)

    Hauser, M.; Burgkhardt, B.; Piesch, E.

    1980-08-01

    In personnel monitoring pocket dosimeters with build-in alarm devices are increasingly in use. The report presents results of a test performed at Karlsruhe. The properties investigated are above all linearity and reproducibility of the dose reading as well as of the acustic alarm indication, dependence on the dose reading, the photon energy, the direction of the radiation incidence, the dose rate, the temperature and operational characteristic of the batteries. (orig./HP) [de

  4. Development of methods and means to improve a performance of microprocessor shock sensors for car alarms

    Directory of Open Access Journals (Sweden)

    S. A. Vasyukov

    2014-01-01

    -line adjusting characteristic.The developed shock sensor is implemented as stock-produced items included in the car alarm systems of the trademark “Excellent” (made by JSC Magic Ring Ltd.. Operating experience (about 40 thousand pieces realized now allows a proper adjustment of sensors to be possible on cars with any body type. A sufficient level of the sensor sensitivity proves it. The reliability of sensors is confirmed by failures statistics in use (0,08%. Failures are, usually, caused by the SE coil wire break in a soldering point of the coil leads to the printed circuit. However a number of shortcomings are also revealed.Experimental data processing of a test batch of sensors has shown that existing SE of electromagnetic type have the frequency of free vibrations f 805Hz and a decay constant of transient under shock  0,2s. At these parameters a SE pass-band makes only f 1,5Hz, and the sensor responses only to the shock front, rather than to the secondary vibrations of a body. It is an essential drawback of the narrow-band sensors.The experiments conducted on test batch of sensors (10 samples have shown essentially different sensitivities of sensors under shock in the direction of the sensitivity axis and perpendicular to it. This difference reaches 4-6 gradations of sensitivity. It means that when mounting a sensor on the particular car the orientation of sensitivity axis of the sensor will be of crucial importance that is also a shortcoming.It is shown that overcoming the specified drawbacks is hardly because of the improvement of sensitive elements suspension of electromagnetic sensors. Three-axial accelerometers implemented using MEMS technologies seem to be the most perspective application here.

  5. Survey of approaches for handling static analysis alarms

    NARCIS (Netherlands)

    Muske, T.; Serebrenik, A.

    2016-01-01

    Static analysis tools have showcased their importance and usefulness in automated detection of code anomalies and defects. However, the large number of alarms reported and cost incurred in their manual inspections have been the major concerns with the usage of static analysis tools. Existing studies

  6. Maximizing semi-active vibration isolation utilizing a magnetorheological damper with an inner bypass configuration

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xian-Xu, E-mail: bai@hfut.edu.cn [Department of Vehicle Engineering, Hefei University of Technology, Hefei 230009 (China); Wereley, Norman M.; Hu, Wei [Department of Aerospace Engineering, University of Maryland, College Park, Maryland 20742 (United States)

    2015-05-07

    A single-degree-of-freedom (SDOF) semi-active vibration control system based on a magnetorheological (MR) damper with an inner bypass is investigated in this paper. The MR damper employing a pair of concentric tubes, between which the key structure, i.e., the inner bypass, is formed and MR fluids are energized, is designed to provide large dynamic range (i.e., ratio of field-on damping force to field-off damping force) and damping force range. The damping force performance of the MR damper is modeled using phenomenological model and verified by the experimental tests. In order to assess its feasibility and capability in vibration control systems, the mathematical model of a SDOF semi-active vibration control system based on the MR damper and skyhook control strategy is established. Using an MTS 244 hydraulic vibration exciter system and a dSPACE DS1103 real-time simulation system, experimental study for the SDOF semi-active vibration control system is also conducted. Simulation results are compared to experimental measurements.

  7. Active Vibration Suppression of a 3-DOF Flexible Parallel Manipulator Using Efficient Modal Control

    Directory of Open Access Journals (Sweden)

    Quan Zhang

    2014-01-01

    Full Text Available This paper addresses the dynamic modeling and efficient modal control of a planar parallel manipulator (PPM with three flexible linkages actuated by linear ultrasonic motors (LUSM. To achieve active vibration control, multiple lead zirconate titanate (PZT transducers are mounted on the flexible links as vibration sensors and actuators. Based on Lagrange’s equations, the dynamic model of the flexible links is derived with the dynamics of PZT actuators incorporated. Using the assumed mode method (AMM, the elastic motion of the flexible links are discretized under the assumptions of pinned-free boundary conditions, and the assumed mode shapes are validated through experimental modal test. Efficient modal control (EMC, in which the feedback forces in different modes are determined according to the vibration amplitude or energy of their own, is employed to control the PZT actuators to realize active vibration suppression. Modal filters are developed to extract the modal displacements and velocities from the vibration sensors. Numerical simulation and vibration control experiments are conducted to verify the proposed dynamic model and controller. The results show that the EMC method has the capability of suppressing multimode vibration simultaneously, and both the structural and residual vibrations of the flexible links are effectively suppressed using EMC approach.

  8. A Comparison of Vibration and Oil Debris Gear Damage Detection Methods Applied to Pitting Damage

    Science.gov (United States)

    Dempsey, Paula J.

    2000-01-01

    Helicopter Health Usage Monitoring Systems (HUMS) must provide reliable, real-time performance monitoring of helicopter operating parameters to prevent damage of flight critical components. Helicopter transmission diagnostics are an important part of a helicopter HUMS. In order to improve the reliability of transmission diagnostics, many researchers propose combining two technologies, vibration and oil monitoring, using data fusion and intelligent systems. Some benefits of combining multiple sensors to make decisions include improved detection capabilities and increased probability the event is detected. However, if the sensors are inaccurate, or the features extracted from the sensors are poor predictors of transmission health, integration of these sensors will decrease the accuracy of damage prediction. For this reason, one must verify the individual integrity of vibration and oil analysis methods prior to integrating the two technologies. This research focuses on comparing the capability of two vibration algorithms, FM4 and NA4, and a commercially available on-line oil debris monitor to detect pitting damage on spur gears in the NASA Glenn Research Center Spur Gear Fatigue Test Rig. Results from this research indicate that the rate of change of debris mass measured by the oil debris monitor is comparable to the vibration algorithms in detecting gear pitting damage.

  9. Influence of vibration on structure rheological properties of a highly concentrated suspension

    Science.gov (United States)

    Ouriev Uriev, Boris N.; Uriev, Naum B.

    2005-08-01

    The influence of mechanical vibration on the flow properties of a highly concentrated multiphase food system is explored in this work. An experimental set-up was designed and adapted to a conventional rotational rheometer with precise rheological characterization capability. A number of calibration tests were performed prior to fundamental experiments with a highly concentrated chocolate suspension. Also, the prediction of wall slippage in shear flow under vibration was evaluated. Analysis of the boundary conditions shows that no side effects such as wall slippage or the Taylor effect were present during the shear experiment under vibration. It was found that superposition of mechanical vibration and shear flow radically decreases the shear viscosity. Comparison between reference shear viscosities at specified shear rates and those measured under vibration shows considerable differences in flow properties. Conversion of the behaviour of the concentrated suspension from strongly shear-thinning to Newtonian flow is reported. Also, the appearance of vibration-induced dilatancy as a new phenomenon is described. It is suggested to relate such phenomena to the non-equilibrium between structure formation and disintegration under vibration and hydrodynamic forces of shear flow. The influence of vibration on structure formation can be well observed during measurement of the yield value of the chocolate suspension under vibration. Comparison with reference data shows how sensitive the structure of the concentrated suspension is to vibration in general. The effects and observations revealed provide a solid basis for further fundamental investigations of structure formation regularities in the flow of any highly concentrated system. The results also show the technological potential for non-conventional treatment of concentrated, multiphase systems.

  10. Network-Based Real-time Integrated Fire Detection and Alarm (FDA) System with Building Automation

    Science.gov (United States)

    Anwar, F.; Boby, R. I.; Rashid, M. M.; Alam, M. M.; Shaikh, Z.

    2017-11-01

    Fire alarm systems have become increasingly an important lifesaving technology in many aspects, such as applications to detect, monitor and control any fire hazard. A large sum of money is being spent annually to install and maintain the fire alarm systems in buildings to protect property and lives from the unexpected spread of fire. Several methods are already developed and it is improving on a daily basis to reduce the cost as well as increase quality. An integrated Fire Detection and Alarm (FDA) systems with building automation was studied, to reduce cost and improve their reliability by preventing false alarm. This work proposes an improved framework for FDA system to ensure a robust intelligent network of FDA control panels in real-time. A shortest path algorithmic was chosen for series of buildings connected by fiber optic network. The framework shares information and communicates with each fire alarm panels connected in peer to peer configuration and declare the network state using network address declaration from any building connected in network. The fiber-optic connection was proposed to reduce signal noises, thus increasing large area coverage, real-time communication and long-term safety. Based on this proposed method an experimental setup was designed and a prototype system was developed to validate the performance in practice. Also, the distributed network system was proposed to connect with an optional remote monitoring terminal panel to validate proposed network performance and ensure fire survivability where the information is sequentially transmitted. The proposed FDA system is different from traditional fire alarm and detection system in terms of topology as it manages group of buildings in an optimal and efficient manner.Introduction

  11. False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.

    Science.gov (United States)

    Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa

    2015-02-09

    False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  12. Chemical alarm in the termite Termitogeton planus (Rhinotermitidae)

    Czech Academy of Sciences Publication Activity Database

    Dolejšová, Klára; Krasulová, Jana; Kutalová, K.; Hanus, Robert

    2014-01-01

    Roč. 40, 11/12 (2014), s. 1269-1276 ISSN 0098-0331 R&D Projects: GA ČR GAP506/10/1570 Institutional support: RVO:61388963 Keywords : termites * soldiers * frontal gland * alarm pheromone * Rhinotermitidae * Termitogeton Subject RIV: CC - Organic Chemistry Impact factor: 2.747, year: 2014

  13. 16 x 16 Vantage+ Fuel Assembly Flow Vibrational Testing

    International Nuclear Information System (INIS)

    Chambers, Martin; Kurincic, Bojan

    2014-01-01

    Nuklearna Elektrarna Krsko (NEK) has experienced leaking fuel after increasing the cycle duration to 18 months. The leaking fuel mechanism has predominantly been consistent over multiple cycles and is typically observed in highly irradiated Fuel Assemblies (FA) after around 4 years of continuous operation that were located at the core periphery (baffle). The cause of the leaking fuel is due to Grid-To-Rod-Fretting (GRTF) and occasional debris fretting. NEK utilises a 16x16 Vantage+ FA design with all Inconel structural mixing vane grids (8 in total), Zirlo thimbles, Integral Fuel Burnable Absorber (IFBA) rods with enriched ZrB2, enriched Annular Blanket, Debris Filter Bottom Nozzle (DFBN), Removable Top Nozzle (RTN) and Zirlo fuel cladding material with a high burnup capability of 60 GWD/MTU. Numerous design and operational changes are thought to have reduced the original 16x16 FA design margin to fretting resistance of either vibration or its wear work rate, such as significant power uprate (spring force loss, rod creep down...), operational cycle duration increase from 12 to 18 months (increasing residence time as well as lead FA and fuel rod burnup values), Reactor Coolant System flow increase (increased vibration), removal of Thimble Plugs (increased bypass flow, increased vibration) and Zirc-4 to Zirlo cladding change (decreasing wear work rate). The fuel rod to grid spring as well as dimple contact areas are relatively smaller than other FA designs that exhibit good in-reactor fretting performance. A FA design change project to address the small rod to dimple / spring contact area and utilise fuel cladding oxide coating is currently being pursued with the fuel supplier. The FA vibrational properties are very important to the in-reactor FA performance and reliability. The 16x16 Vantage+ vibrational testing was performed with a full size FA in the Fuel Assembly Compatibility Testing (FACTS) loop that is able to provide full flow rates at elevated temperature

  14. Integrated knowledge base tool for acquisition and verification of NPP alarm systems

    International Nuclear Information System (INIS)

    Park, Joo Hyun; Seong, Poong Hyun

    1998-01-01

    Knowledge acquisition and knowledge base verification are important activities in developing knowledge-based systems such as alarm processing systems. In this work, we developed the integrated tool, for knowledge acquisition and verification of NPP alarm processing systems, by using G2 tool. The tool integrates document analysis method and ECPN matrix analysis method, for knowledge acquisition and knowledge verification, respectively. This tool enables knowledge engineers to perform their tasks from knowledge acquisition to knowledge verification consistently

  15. Development and Characteristics of an ANSI/ANS-8-3-1997-Compliant Criticality Alarm

    International Nuclear Information System (INIS)

    McMahan, J.W.

    2002-01-01

    A Criticality Alarm System (CAS) was developed at the Savannah River Site (SRS) beginning in 1964, which used an ionization chamber and battery - powered tube amplifier. Three generations of improvements are described here, to improve reliability, reduce maintenance cost, and eliminate false alarms. The original configuration for the CAS instrument (called Nuclear Incident Monitor-NIM model I) was a single chassis containing all components including the batteries and the detector, and a warning bell and light. To decrease the contamination potential of NIMs, the detector can now be removed from the chassis and remotely located for some installations. In the presently used second generation model II, each unit consists of an ion chamber with electrometer amplifier, voltage comparator circuits, battery and power supplies, monitoring circuits, and relay alarm circuits. The electrometer circuit is housed with the ion chamber in an aluminum enclosure. The remaining components are located in the main chassis. An alarm point of one R per Hour is adjustable over a narrow range for calibration purposes. Evacuation zones were determined on a 25 rad dose basis, and then modified to the 12 rad level

  16. Vibration mixer

    Energy Technology Data Exchange (ETDEWEB)

    Alekhin, S.A.; Chernov, V.S.; Denisenko, V.V.; Gorodnyanskiy, I.F.; Prokopov, L.I.; Tikhonov, Yu.P.

    1983-01-01

    The vibration mixer is proposed which contains a housing, vibration drive with rod installed in the upper part of the mixing mechanism made in the form of a hollow shaft with blades. In order to improve intensity of mixing and dispersion of the mud, the shaft with the blades is arranged on the rod of the vibrator and is equipped with a cam coupling whose drive disc is attached to the vibration rod. The rod is made helical, while the drive disc of the cam coupling is attached to the helical surface of the rod. In addition, the vibration mixer is equipped with perforated discs installed on the ends of the rods.

  17. Video systems for alarm assessment

    International Nuclear Information System (INIS)

    Greenwoll, D.A.; Matter, J.C.; Ebel, P.E.

    1991-09-01

    The purpose of this NUREG is to present technical information that should be useful to NRC licensees in designing closed-circuit television systems for video alarm assessment. There is a section on each of the major components in a video system: camera, lens, lighting, transmission, synchronization, switcher, monitor, and recorder. Each section includes information on component selection, procurement, installation, test, and maintenance. Considerations for system integration of the components are contained in each section. System emphasis is focused on perimeter intrusion detection and assessment systems. A glossary of video terms is included. 13 figs., 9 tabs

  18. Video systems for alarm assessment

    Energy Technology Data Exchange (ETDEWEB)

    Greenwoll, D.A.; Matter, J.C. (Sandia National Labs., Albuquerque, NM (United States)); Ebel, P.E. (BE, Inc., Barnwell, SC (United States))

    1991-09-01

    The purpose of this NUREG is to present technical information that should be useful to NRC licensees in designing closed-circuit television systems for video alarm assessment. There is a section on each of the major components in a video system: camera, lens, lighting, transmission, synchronization, switcher, monitor, and recorder. Each section includes information on component selection, procurement, installation, test, and maintenance. Considerations for system integration of the components are contained in each section. System emphasis is focused on perimeter intrusion detection and assessment systems. A glossary of video terms is included. 13 figs., 9 tabs.

  19. Attention Cueing and Activity Equally Reduce False Alarm Rate in Visual-Auditory Associative Learning through Improving Memory.

    Science.gov (United States)

    Nikouei Mahani, Mohammad-Ali; Haghgoo, Hojjat Allah; Azizi, Solmaz; Nili Ahmadabadi, Majid

    2016-01-01

    In our daily life, we continually exploit already learned multisensory associations and form new ones when facing novel situations. Improving our associative learning results in higher cognitive capabilities. We experimentally and computationally studied the learning performance of healthy subjects in a visual-auditory sensory associative learning task across active learning, attention cueing learning, and passive learning modes. According to our results, the learning mode had no significant effect on learning association of congruent pairs. In addition, subjects' performance in learning congruent samples was not correlated with their vigilance score. Nevertheless, vigilance score was significantly correlated with the learning performance of the non-congruent pairs. Moreover, in the last block of the passive learning mode, subjects significantly made more mistakes in taking non-congruent pairs as associated and consciously reported lower confidence. These results indicate that attention and activity equally enhanced visual-auditory associative learning for non-congruent pairs, while false alarm rate in the passive learning mode did not decrease after the second block. We investigated the cause of higher false alarm rate in the passive learning mode by using a computational model, composed of a reinforcement learning module and a memory-decay module. The results suggest that the higher rate of memory decay is the source of making more mistakes and reporting lower confidence in non-congruent pairs in the passive learning mode.

  20. Preventive measures against vibration of FBR reactor vessel cooling structure

    International Nuclear Information System (INIS)

    Eguchi, Yuzuru; Tanaka, Nobukazu

    1989-01-01

    The present paper describes the fundamental feature of the fluid-elastic vibration of flexible overflow weir, as observed in the French demonstration fast breeder reactor, Super Phenix-1. In the experimental study, the instability criterion of the fluid-elastic vibration was studied by using a simple experimental apparatus of a rectangular tank separated by a flexible weir. A spring-mass model was developed to clarify the mechanism of the instability. The instability condition was analytically derived from the equations of the spring-mass model. The equations of the spring-mass model was also computationally integrated in time to simulate the temporal evolution of the fluid-elastic vibration. The comparison between the experimental and theoretical results indicates that the present theoretical model is capable of predicting most of the physical tendencies observed in the experiment. The present study revealed that the lag time of waterfall at the weir is the most influential parameter among other hydro-elastic parameters. (author)

  1. Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2016-01-01

    BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for

  2. Vibration-Based Damage Detection in Beams by Cooperative Coevolutionary Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Kittipong Boonlong

    2014-03-01

    Full Text Available Vibration-based damage detection, a nondestructive method, is based on the fact that vibration characteristics such as natural frequencies and mode shapes of structures are changed when the damage happens. This paper presents cooperative coevolutionary genetic algorithm (CCGA, which is capable for an optimization problem with a large number of decision variables, as the optimizer for the vibration-based damage detection in beams. In the CCGA, a minimized objective function is a numerical indicator of differences between vibration characteristics of the actual damage and those of the anticipated damage. The damage detection in a uniform cross-section cantilever beam, a uniform strength cantilever beam, and a uniform cross-section simply supported beam is used as the test problems. Random noise in the vibration characteristics is also considered in the damage detection. In the simulation analysis, the CCGA provides the superior solutions to those that use standard genetic algorithms presented in previous works, although it uses less numbers of the generated solutions in solution search. The simulation results reveal that the CCGA can efficiently identify the occurred damage in beams for all test problems including the damage detection in a beam with a large number of divided elements such as 300 elements.

  3. False Alarm Reduction in BSN-Based Cardiac Monitoring Using Signal Quality and Activity Type Information

    Directory of Open Access Journals (Sweden)

    Tanatorn Tanantong

    2015-02-01

    Full Text Available False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs, the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  4. Integrated Vibration and Acceleration Testing to Reduce Payload Mass, Cost and Mission Risk, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a capability to provide integrated acceleration, vibration, and shock testing using a state-of-the-art centrifuge, allowing for the test of...

  5. Theory of vibration protection

    CERN Document Server

    Karnovsky, Igor A

    2016-01-01

    This text is an advancement of the theory of vibration protection of mechanical systems with lumped and distributed parameters. The book offers various concepts and methods of solving vibration protection problems, discusses the advantages and disadvantages of different methods, and the fields of their effective applications. Fundamental approaches of vibration protection, which are considered in this book, are the passive, parametric and optimal active vibration protection. The passive vibration protection is based on vibration isolation, vibration damping and dynamic absorbers. Parametric vibration protection theory is based on the Shchipanov-Luzin invariance principle. Optimal active vibration protection theory is based on the Pontryagin principle and the Krein moment method. The book also contains special topics such as suppression of vibrations at the source of their occurrence and the harmful influence of vibrations on humans. Numerous examples, which illustrate the theoretical ideas of each chapter, ar...

  6. Criticality alarm device

    International Nuclear Information System (INIS)

    Sasaki, Takashi.

    1995-01-01

    In a critical alarm device comprising an n-number of radiation detectors and a 2/3 logic module, the 2/3 logic module comprises a rectifier inputting an output of an AC power and outputting it as a full wave-rectified, DC voltage, an analog/digital converter inputting the output from the rectifier, putting it to analog/digital conversion and continuously storing it into a memory, a latch circuit inputting critical signals from the 2/3 logic and holding them and outputting latch signals, and a means for outputting timing signals for data storage to a memory based on clocks at a predetermined period and outputting timing signals for stopping the data storage to the memory after passing a predetermined period from the inputting time point if the latch signals are inputted from the latch circuit. Then, judgement whether the generation of criticality is caused by an actual radiation detection or by noises from the power source is enabled, to provide extremely high reliability. (N.H.)

  7. Alarm management system

    International Nuclear Information System (INIS)

    Woods, D.D.; Elm, W.C.; Lipner, M.H.; Butterworth, G.E.; Easter, J.R.

    1989-01-01

    An alarm management system is described, comprising: a light water pressurized nuclear power plant; sensors coupled to the plant indicating the state of the plant; a sensor signal processor, operatively connected to the sensors, for producing state signals indicating the state of the sensors monitoring the power plant from the sensor signals and for combining the state signals using rule based algorithms to produce abnormality indication signals; a message processor, operatively connected to the sensor signal processor for receiving the abnormality indication signals; a spatially dedicated parallel display for each function, operatively connected to the message processor, for displaying the portion of the messages simultaneously; and a serial display, operatively connected to the message processor, for displaying the message in the queues in priority order within category within function upon request, the message processor outputting messages from the queue to the parallel display as display space becomes available on the parallel display due to an abnormality being resolved

  8. Benefit of an electronic medical record-based alarm in the optimization of stress ulcer prophylaxis.

    Science.gov (United States)

    Saad, Emanuel José; Bedini, Marianela; Becerra, Ana Florencia; Martini, Gustavo Daniel; Gonzalez, Jacqueline Griselda; Bolomo, Andrea; Castellani, Luciana; Quiroga, Silvana; Morales, Cristian; Leathers, James; Balderramo, Domingo; Albertini, Ricardo Arturo

    2018-06-09

    The use of stress ulcer prophylaxis (SUP) has risen in recent years, even in patients without a clear indication for therapy. To evaluate the efficacy of an electronic medical record (EMR)-based alarm to improve appropriate SUP use in hospitalized patients. We conducted an uncontrolled before-after study comparing SUP prescription in intensive care unit (ICU) patients and non-ICU patients, before and after the implementation of an EMR-based alarm that provided the correct indications for SUP. 1627 patients in the pre-intervention and 1513 patients in the post-intervention cohorts were included. The EMR-based alarm improved appropriate (49.6% vs. 66.6%, p<0.001) and reduced inappropriate SUP use (50.4% vs. 33.3%, p<0.001) in ICU patients only. These differences were related to the optimization of SUP in low risk patients. There was no difference in overt gastrointestinal bleeding between the two cohorts. Unjustified costs related to SUP were reduced by a third after EMR-based alarm use. The use of an EMR-based alarm improved appropriate and reduced inappropriate use of SUP in ICU patients. This benefit was limited to optimization in low risk patients and associated with a decrease in SUP costs. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  9. Vibration of machine

    International Nuclear Information System (INIS)

    Kwak, Mun Gyu; Na, Sung Su; Baek, Gwang Hyeon; Song, Chul Gi; Han, Sang Bo

    2001-09-01

    This book deals with vibration of machine which gives descriptions of free vibration using SDOF system, forced vibration using SDOF system, vibration of multi-degree of freedom system like introduction and normal form, distribution system such as introduction, free vibration of bar and practice problem, approximate solution like lumped approximations and Raleigh's quotient, engineering by intuition and experience, real problem and experimental method such as technology of signal, fourier transform analysis, frequency analysis and sensor and actuator.

  10. A model of objects based on KKS for the processing of alarms at the Angra 2 nuclear power plant; Um modelo de objetos baseado em KKS para o processamento de alarmes da usina nuclear de Angra 2

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Paulo Adriano da

    2000-03-01

    The purpose of this work is to present a new model of the alarm annunciation system of the Angra 2 nuclear power plant, using concepts of object based modeling and having as basic the Angra 2 Systems and Components Identification System - KKS. The present structure of the Computerized Alarm System - CAS of Angra 2 does not permit a fast visualization of the incoming alarms in case that a great number of them go off, because the monitors can only show 7 indications at a time. The herein proposed model permits a fast identification of the generated alarms, making possible for the operator to have a general view of the current nuclear power plant status. Its managing tree structure has an hierarchical dependence among its nodes, from where, the presently activated alarms are shown. Its man-machine interface is easy interaction and understand because it is based on structure well known by the Angra 2 operators which is the Angra 2 Systems and Components Identification System - KKS. The project was implemented in the format of an Angra 2 Alarms Supervision System (SSAA), and, for purpose of simulation, 5 system of the Angra 2 Nuclear Power Plant have been chosen. The data used in the project like measurement KKS, measurement limits, unity, setpoints, alarms text and systems flow diagrams, are actual data of the Angra 2 Nuclear Power Plant. The Visual Basic programming Language has been used, with emphasis to the object oriented programming, which and modification, without modifying the program code. Event hough using the Visual Basic for programming, the model has shown, for its purpose, a satisfactory real time execution. (author)

  11. Development of electric power transmission line anomaly approaching alarm system. Sodensen ijo sekkin keiho sochi no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kusaba, Masaro; Tabata, Takatoshi; Miyazaki, Shusuke [Kyushu Electric Power Co., Inc., Fukuoka (Japan)

    1989-03-30

    In order to plan preventive measures from the occurrence of electric power transmission line accident, a power transmission line anomaly approaching alarm system was developed to automatically alarm the operators and surveillants. The surveillance system, composed of camera, surveillance unit proper and alarm receiving portion, generates alarm and indicate hazard to the operators, when animal invades a hazardous area designated on the monitor. Wireless telegraph for the alarm transmission use used frequency around a 322MHz band with the Radio Ray law and preventive measures from noise, taken into consideration. The prototype is characterized by unnecessary ancillary fitting to the surveillance object, rare erroneous operations and high reliability. While the hazardous area can be simply designated, changed and released, as made by volume on the control panel. It is moreover easy to designate, as done by confirming the surveillance object on the display. It is also possible in multidimensional surveillance and easy to use on site. 7 figs.

  12. Exploration on a Modern Positive Social Alarming System%现代实证性社会预警的探索

    Institute of Scientific and Technical Information of China (English)

    阎耀军

    2005-01-01

    A new theoretical model of social alarming index system with its operational platforms was constructed on the basis of the research on modem positive social alarming systems at home and abroad. A retrospective evaluation of the state of social harmony and stability in China from 1985 to 2002 and a simulation of social alarming feedback loops empirically examined the effectiveness of this new social alarming index system.

  13. Decreasing the false alarm rate of arrhythmias in intensive care using a machine learning approach

    NARCIS (Netherlands)

    Eerikäinen, L.M.; Vanschoren, J.; Rooijakkers, M.J.; Vullings, R.; Aarts, R.M.

    2015-01-01

    We present a novel algorithm for classifying true and false alarms of five life-threatening arrhythmias in intensive care. This algorithm was entered in the PhysioNet/Computing in Cardiology Challenge 2015 Reducing False Arrhythmia Alarms in the ICU. The algorithm performs a binary classification of

  14. Vibration control for precision manufacturing using piezoelectric actuators

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, D.R.; Hinnerichs, T.D.; Redmond, J.M.

    1995-12-31

    Piezoelectric actuators provide high frequency, force, and stiffness capabilities along with reasonable Stroke limits, all of which can be used to increase performance levels in precision manufacturing systems. This paper describes two examples of embedding piezoelectric actuators in structural components for vibration control. One example involves suppressing the self excited chatter phenomenon in the metal cutting process of a milling machine and the other involves damping vibrations induced by rigid body stepping of a photolithography platen. Finite element modeling and analyses are essential for locating and sizing the actuators and permit further simulation studies of the response of the dynamic system. Experimental results are given for embedding piezoelectric actuators in a cantilevered bar configuration, which was used as a surrogate machine tool structure. These results are incorporated into a previously developed milling process simulation and the effect of the control on the cutting process stability diagram is quantified. Experimental results are also given for embedding three piezoelectric actuators in a surrogate photolithography platen to suppress vibrations. These results demonstrate the potential benefit that can be realized by applying advances from the field of adaptive structures to problems in precision manufacturing.

  15. Automatic diagnosis of multiple alarms for reactor-control rooms

    International Nuclear Information System (INIS)

    Gimmy, K.L.; Nomm, E.

    1981-01-01

    A system has been developed at the Savannah River Plant to help reactor operators respond to multiple alarms in a developing incident situation. The need for such systems has become evident in recent years, particularly after the three Mile Island incident

  16. Car glass microphones using piezoelectric transducers for external alarm detection and localization

    Science.gov (United States)

    Bolzmacher, Christian; Le Guelvouit, Valentin

    2015-05-01

    This work describes the potential use of car windows as a long range acoustic sensing device for external alarm signals. The goal is to detect and localize siren signals (e.g. ambulances and police cars) and to alert presbycusic drivers of its presence by visual and acoustic feedback in order to improve individual mobility and increase the sense of security. The glass panes of a Renault Zoé operating as an acoustic antenna have been equipped with large 50 mm outer diameter piezoceramic rings, hidden in the lower part of the door structure and the lower part of the windshield and the rear window. The response of the glass to quasi-static signals and sweep excitation has been recorded. In general, the glass pane is acting as a high pass filter due to its inherent stiffness and provides only little damping. This effect is compensated by using a charge amplifier electronic circuit. The detection capability up to 120 m as well as a dynamic test where the car is moving towards the sound source is reported.

  17. Associations between health care seeking and socioeconomic and demographic determinants among people reporting alarm symptoms of cancer

    DEFF Research Database (Denmark)

    Svendsen, Rikke P; Jarbol, Dorte E; Larsen, Pia V

    2013-01-01

    Late diagnosis of cancer may partly be explained by the fact that some patients do not seek health care promptly when experiencing an alarm symptom. Socioeconomic and demographic differences exist concerning knowledge and awareness of cancer alarm symptoms in the general population...... and socioeconomic differences are found in cancer incidence and survival. We therefore hypothesise that socioeconomic and demographic differences in health care-seeking behaviour are present among people with alarm symptoms....

  18. Utilizing Facebook and Automated Telephone Calls to Increase Adoption of a Local Smoke Alarm Installation Program.

    Science.gov (United States)

    Frattaroli, Shannon; Schulman, Eric; McDonald, Eileen M; Omaki, Elise C; Shields, Wendy C; Jones, Vanya; Brewer, William

    2018-05-17

    Innovative strategies are needed to improve the prevalence of working smoke alarms in homes. To our knowledge, this is the first study to report on the effectiveness of Facebook advertising and automated telephone calls as population-level strategies to encourage an injury prevention behavior. We examine the effectiveness of Facebook advertising and automated telephone calls as strategies to enroll individuals in Baltimore City's Fire Department's free smoke alarm installation program. We directed our advertising efforts toward Facebook users eligible for the Baltimore City Fire Department's free smoke alarm installation program and all homes with a residential phone line included in Baltimore City's automated call system. The Facebook campaign targeted Baltimore City residents 18 years of age and older. In total, an estimated 300 000 Facebook users met the eligibility criteria. Facebook advertisements were delivered to users' desktop and mobile device newsfeeds. A prerecorded message was sent to all residential landlines listed in the city's automated call system. By the end of the campaign, the 3 advertisements generated 456 666 impressions reaching 130 264 Facebook users. Of the users reached, 4367 individuals (1.3%) clicked the advertisement. The automated call system included approximately 90 000 residential phone numbers. Participants attributed 25 smoke alarm installation requests to Facebook and 458 to the automated call. Facebook advertisements are a novel approach to promoting smoke alarms and appear to be effective in exposing individuals to injury prevention messages. However, converting Facebook message recipients to users of a smoke alarm installation program occurred infrequently in this study. Residents who participated in the smoke alarm installation program were more likely to cite the automated call as the impetus for their participation. Additional research is needed to understand the circumstances and strategies to effectively use the social

  19. Advanced pulse oximeter signal processing technology compared to simple averaging. II. Effect on frequency of alarms in the postanesthesia care unit.

    Science.gov (United States)

    Rheineck-Leyssius, A T; Kalkman, C J

    1999-05-01

    To determine the effect of a new pulse oximeter (Nellcor Symphony N-3000, Pleasanton, CA) with signal processing technique (Oxismart) on the incidence of false alarms in the postanesthesia care unit (PACU). Prospective study. Nonuniversity hospital. 603 consecutive ASA physical status I, II, and III patients recovering from general or regional anesthesia in the PACU. We compared the number of alarms produced by a recently developed "third"-generation pulse oximeter (Nellcor Symphony N-3000) with Oxismart signal processing technique and a conventional pulse oximeter (Criticare 504, Waukesha, WI). Patients were randomly assigned to either a Nellcor pulse oximeter or a Criticare with the signal averaging time set at either 12 or 21 seconds. For each patient the number of false (artifact) alarms was counted. The Nellcor generated one false alarm in 199 patients and 36 (in 31 patients) "loss of pulse" alarms. The conventional pulse oximeter with the averaging time set at 12 seconds generated a total of 32 false alarms in 17 of 197 patients [compared with the Nellcor, relative risk (RR) 0.06, confidence interval (CI) 0.01 to 0.25] and a total of 172 "loss of pulse" alarms in 79 patients (RR 0.39, CI 0.28 to 0.55). The conventional pulse oximeter with the averaging time set at 21 seconds generated 12 false alarms in 11 of 207 patients (compared with the Nellcor, RR 0.09, CI 0.02 to 0.48) and a total of 204 "loss of pulse" alarms in 81 patients (RR 0.40, CI 0.28 to 0.56). The lower incidence of false alarms of the conventional pulse oximeter with the longest averaging time compared with the shorter averaging time did not reach statistical significance (false alarms RR 0.62, CI 0.3 to 1.27; "loss of pulse" alarms RR 0.98, CI 0.77 to 1.3). To date, this is the first report of a pulse oximeter that produced almost no false alarms in the PACU.

  20. Two methods for damping torsional vibrations in DFIG-based wind generators using power converters

    Science.gov (United States)

    Zhao, Zuyi; Lu, Yupu; Xie, Da; Yu, Songtao; Wu, Wangping

    2017-01-01

    This paper proposes novel damping control algorithms by using static synchronous compensator (STATCOM) and energy storage system (ESS) to damp torsional vibrations in doubly fed induction generator (DFIG) based wind turbine systems. It first analyses the operating characteristics of STATCOM and ESS for regulating power variations to increase grid voltage stability. Then, new control strategies for STATCOM and ESS are introduced to damp the vibrations. It is followed by illustration of their effectiveness to damp the drive train torsional vibrations of wind turbines, which can be caused by grid disturbances, such as voltage sags and frequency fluctuations. Results suggest that STATCOM is a promising technology to mitigate the torsional vibrations caused by grid voltage sags. By contrast, the ESS connected to the point of common coupling (PCC) of wind turbine systems shows even obvious advantages because of its capability of absorbing/releasing both active and reactive power. It can thus be concluded that STATCOM is useful for stabilizing power system voltage fluctuations, and ESS is more effective both in regulating PCC voltage fluctuations and damping torsional vibrations caused by grid voltage frequency fluctuations.

  1. Validation of the Rome III criteria and alarm symptoms for recurrent abdominal pain in children.

    Science.gov (United States)

    Gijsbers, Carolien F M; Benninga, Marc A; Schweizer, Joachim J; Kneepkens, C M Frank; Vergouwe, Yvonne; Büller, Hans A

    2014-06-01

    Rome criteria were formulated to define functional gastrointestinal disorders (Rome III criteria, 2006) excluding organic diagnoses when alarm symptoms were absent. The aims of the study were to validate the Rome III criteria as to their capacity to differentiate between organic and functional abdominal pain and to assess the role of alarm symptoms in this differentiation. During 2 years all of the patients (ages 4-16 years) presenting with recurrent abdominal pain (Apley criteria) and referred to secondary care were included. Clinical diagnoses were based on protocolized evaluation and intervention with 6-month follow-up. Alarm symptoms were registered. Rome III criteria for functional pain syndromes were assigned independently. Descriptive statistical analyses were performed. In 200 patients (87 boys, mean age 8.8 years), organic (17%), functional (40%), combined organic and functional (9%), spontaneous recovery (27%), and other (8%) clinical diagnoses were established. Alarm symptoms were found in 57.5% (organic causes 56%, functional causes 61%). The evaluation for Rome symptom clusters revealed symptoms of irritable bowel syndrome in 27%, functional dyspepsia in 15%, functional abdominal pain in 28%, functional abdominal pain syndrome in 14.5%, and no pain syndrome in 15.5%. Rome diagnoses, based on symptoms and absence of alarm symptoms, predicted functional clinical diagnosis with sensitivity 0.35 (95% confidence interval 0.27-0.43), specificity 0.60 (0.46-0.73), positive predictive value 0.71 (0.61-0.82), and negative predictive value of 0.24 (0.17-0.32). The Rome III criteria for abdominal pain are not specific enough to rule out organic causes. Alarm symptoms do not differentiate between organic and functional abdominal pain.

  2. Effects of natural and synthetic alarm pheromone and individual pheromone components on foraging behavior of the giant Asian honey bee, Apis dorsata.

    Science.gov (United States)

    Li, Jianjun; Wang, Zhengwei; Tan, Ken; Qu, Yufeng; Nieh, James C

    2014-10-01

    Social pollinators such as honey bees face attacks from predators not only at the nest, but also during foraging. Pollinating honey bees can therefore release alarm pheromones that deter conspecifics from visiting dangerous inflorescences. However, the effect of alarm pheromone and its chemical components upon bee avoidance of dangerous food sources remains unclear. We tested the responses of giant honey bee foragers, Apis dorsata, presented with alarm pheromone at a floral array. Foragers investigated the inflorescence with natural alarm pheromone, but 3.3-fold more foragers preferred to land on the 'safe' inflorescence without alarm pheromone. Using gas chromatography-mass spectrometry analysis, we identified eight chemical components in the alarm pheromone, of which three components (1-octanol, decanal and gamma-octanoic lactone) have not previously been reported in this species. We bioassayed six major compounds and found that a synthetic mixture of these compounds elicited behaviors statistically indistinguishable from responses to natural alarm pheromone. By testing each compound separately, we show that gamma-octanoic lactone, isopentyl acetate and (E)-2-decen-1-yl acetate are active compounds that elicit significant alarm responses. Gamma-octanoic lactone elicited the strongest response to a single compound and has not been previously reported in honey bee alarm pheromone. Isopentyl acetate is widely found in the alarm pheromones of sympatric Asian honey bee species, and thus alarmed A. dorsata foragers may produce information useful for conspecifics and heterospecifics, thereby broadening the effects of alarm information on plant pollination. © 2014. Published by The Company of Biologists Ltd.

  3. Intelligent software solution for reliable high efficiency/low false alarm border monitoring

    International Nuclear Information System (INIS)

    Rieck, W.; Iwatschenko, M.

    2001-01-01

    Full text: Radioactivity Monitoring at border stations requires detection systems that are reliably operating under special conditions such as: different types and shapes of vehicles; different velocities; stop and go traffic. ESM has developed a solution that achieves under all such conditions the lowest possible detection limit and avoids false alarms generated by naturally occurring radioactive material (NORM). NBR (Natural Background Reduction) data evaluation - One of the main reasons for the success of the ESM gate monitors is the unique and proprietary NBR-technology of instantaneous discrimination of artificial and natural gamma radiation using large area plastic scintillators. Thus the FHT 1388 gate monitors show 2 unique features: Possible setting of different alarm levels for NORM and artificial gamma sources; Self adjusting compensation of the background shielding of the truck in respect to the detection of artificial sources. Both properties are a preposition for the highly sensitive detection of artificial gamma sources. While at scrap yards and steel mills usually all radioactivity (including NORM) must be detected, the main object of interest in respect to the measuring task at border stations, airports or harbours is clearly the detection of even very small signals of artificial radioactivity. The reliable rejection of the influence of natural radioactivity is of special importance in the case of detection of illicit trafficking, since construction material, fertilisers or soil often lead to much higher detector signals than the alarming levels for dangerous sources of interest. Beside the varying content of natural radioactivity in the load of a truck, different loads and trucks show different influence on the reduction of the ambient radiation due to the passing vehicle. Thus software approaches assuming a specific reduction of the background count rate (regarding relative magnitude and shape) must fail when trucks of different shape and load

  4. The LBT real-time based control software to mitigate and compensate vibrations

    Science.gov (United States)

    Borelli, J.; Trowitzsch, J.; Brix, M.; Kürster, M.; Gässler, W.; Bertram, T.; Briegel, F.

    2010-07-01

    The Large Binocular Telescope (LBT) uses two 8.4 meters active primary mirrors and two adaptive secondary mirrors on the same mounting to take advantage of its interferometric capabilities. Both applications, interferometry and AO, are sensitive to vibrations. Several measurement campaigns have been carried out at the LBT and their results strongly indicate that a vibration monitoring system is required to improve the performance of LINC-NIRVANA, LBTI, and ARGOS, the laser guided ground layer adaptive optic system. Currently, a control software for mitigation and compensation of the vibrations is being designed. A complex set of algorithms collects real-time vibration data, archiving it for further analysis, and in parallel, generating the tip-tilt and optical path difference (OPD) data for the control loop of the instruments. A real-time data acquisition device equipped with embedded real-time Linux is used in our systems. A set of quick-look tools is currently under development in order to verify if the conditions at the telescope are suitable for interferometric/adaptive observations.

  5. Anti-vibration gloves?

    Science.gov (United States)

    Hewitt, Sue; Dong, Ren G; Welcome, Daniel E; McDowell, Thomas W

    2015-03-01

    For exposure to hand-transmitted vibration (HTV), personal protective equipment is sold in the form of anti-vibration (AV) gloves, but it remains unclear how much these gloves actually reduce vibration exposure or prevent the development of hand-arm vibration syndrome in the workplace. This commentary describes some of the issues that surround the classification of AV gloves, the assessment of their effectiveness and their applicability in the workplace. The available information shows that AV gloves are unreliable as devices for controlling HTV exposures. Other means of vibration control, such as using alternative production techniques, low-vibration machinery, routine preventative maintenance regimes, and controlling exposure durations are far more likely to deliver effective vibration reductions and should be implemented. Furthermore, AV gloves may introduce some adverse effects such as increasing grip force and reducing manual dexterity. Therefore, one should balance the benefits of AV gloves and their potential adverse effects if their use is considered. © Crown copyright 2014.

  6. Alarm communication: a new function for the scent-gland secretion in harvestmen (Arachnida: Opiliones)

    Science.gov (United States)

    Machado, Glauco; Bonato, Vinícius; Oliveira, Paulo

    2002-05-01

    Most harvestmen are nocturnal, nonacoustical, and nonvisual arthropods. They have a pair of exocrine glands on the cephalothorax that produce defensive volatile secretions. We investigated in the field the possible alarm effect of these secretions in the gregarious harvestman Goniosoma aff. proximum. A cotton swab soaked with the species' own exudate (treatment), or with water (control), was held 1-2 cm from the center of harvestmen aggregations. The results showed that the gland secretion elicits an alarm response in Goniosoma: whereas 73.3% of the aggregations dispersed after being stimulated with the gland exudate, only 3.3% responded to the water control. Respondent groups are larger than non-respondent groups, and the time of reaction to the secretion was inversely related to group size. This is the first demonstration of a chemically-mediated alarm effect in harvestmen. The alarm response in gregarious harvestmen has possibly evolved as a by-product of a primarily defensive reaction in the context of predator avoidance. The discovery of this novel function of scent-gland secretion is meaningful in view of the widespread occurrence of gregarious habit among species of the order Opiliones.

  7. Engineering Vibrationally Assisted Energy Transfer in a Trapped-Ion Quantum Simulator

    Science.gov (United States)

    Gorman, Dylan J.; Hemmerling, Boerge; Megidish, Eli; Moeller, Soenke A.; Schindler, Philipp; Sarovar, Mohan; Haeffner, Hartmut

    2018-01-01

    Many important chemical and biochemical processes in the condensed phase are notoriously difficult to simulate numerically. Often, this difficulty arises from the complexity of simulating dynamics resulting from coupling to structured, mesoscopic baths, for which no separation of time scales exists and statistical treatments fail. A prime example of such a process is vibrationally assisted charge or energy transfer. A quantum simulator, capable of implementing a realistic model of the system of interest, could provide insight into these processes in regimes where numerical treatments fail. We take a first step towards modeling such transfer processes using an ion-trap quantum simulator. By implementing a minimal model, we observe vibrationally assisted energy transport between the electronic states of a donor and an acceptor ion augmented by coupling the donor ion to its vibration. We tune our simulator into several parameter regimes and, in particular, investigate the transfer dynamics in the nonperturbative regime often found in biochemical situations.

  8. Ultra-low-vibration pulse-tube cryocooler system - cooling capacity and vibration

    Science.gov (United States)

    Ikushima, Yuki; Li, Rui; Tomaru, Takayuki; Sato, Nobuaki; Suzuki, Toshikazu; Haruyama, Tomiyoshi; Shintomi, Takakazu; Yamamoto, Akira

    2008-09-01

    This report describes the development of low-vibration cooling systems with pulse-tube (PT) cryocoolers. Generally, PT cryocoolers have the advantage of lower vibrations in comparison to those of GM cryocoolers. However, cooling systems for the cryogenic laser interferometer observatory (CLIO), which is a gravitational wave detector, require an operational vibration that is sufficiently lower than that of a commercial PT cryocooler. The required specification for the vibration amplitude in cold stages is less than ±1 μm. Therefore, during the development of low-vibration cooling systems for the CLIO, we introduced advanced countermeasures for commercial PT cryocoolers. The cooling performance and the vibration amplitude were evaluated. The results revealed that 4 K and 80 K PT cooling systems with a vibration amplitude of less than ±1 μm and cooling performance of 4.5 K and 70 K at heat loads of 0.5 W and 50 W, respectively, were developed successfully.

  9. Integrating Oil Debris and Vibration Gear Damage Detection Technologies Using Fuzzy Logic

    Science.gov (United States)

    Dempsey, Paula J.; Afjeh, Abdollah A.

    2002-01-01

    A diagnostic tool for detecting damage to spur gears was developed. Two different measurement technologies, wear debris analysis and vibration, were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Test Rig. Experimental data were collected during experiments performed in this test rig with and without pitting. Results show combining the two measurement technologies improves the detection of pitting damage on spur gears.

  10. Sequence and batch language programs and alarm related C Programs for the 242-A MCS

    International Nuclear Information System (INIS)

    Berger, J.F.

    1996-01-01

    A Distributive Process Control system was purchased by Project B-534, 242-A Evaporator/Crystallizer Upgrades. This control system, called the Monitor and Control system (MCS), was installed in the 242-A evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict the overall process. To do this, WTSE developed a second alarm scheme

  11. Advanced pulse oximeter signal processing technology compared to simple averaging. I. Effect on frequency of alarms in the operating room.

    Science.gov (United States)

    Rheineck-Leyssius, A T; Kalkman, C J

    1999-05-01

    To determine the effect of a new signal processing technique (Oxismart, Nellcor, Inc., Pleasanton, CA) on the incidence of false pulse oximeter alarms in the operating room (OR). Prospective observational study. Nonuniversity hospital. 53 ASA physical status I, II, and III consecutive patients undergoing general anesthesia with tracheal intubation. In the OR we compared the number of alarms produced by a recently developed third generation pulse oximeter (Nellcor Symphony N-3000) with Oxismart signal processing technique and a conventional pulse oximeter (Criticare 504). Three pulse oximeters were used simultaneously in each patient: a Nellcor pulse oximeter, a Criticare with the signal averaging time set at 3 seconds (Criticareaverage3s) and a similar unit with the signal averaging time set at 21 seconds (Criticareaverage21s). For each pulse oximeter, the number of false (artifact) alarms was counted. One false alarm was produced by the Nellcor (duration 55 sec) and one false alarm by the Criticareaverage21s monitor (5 sec). The incidence of false alarms was higher in Criticareaverage3s. In eight patients, Criticareaverage3s produced 20 false alarms (p signal processing compared with the Criticare monitor with the longer averaging time of 21 seconds.

  12. Microgravity Active Vibration Isolation System on Parabolic Flights

    Science.gov (United States)

    Dong, Wenbo; Pletser, Vladimir; Yang, Yang

    2016-07-01

    The Microgravity Active Vibration Isolation System (MAIS) aims at reducing on-orbit vibrations, providing a better controlled lower gravity environment for microgravity physical science experiments. The MAIS will be launched on Tianzhou-1, the first cargo ship of the China Manned Space Program. The principle of the MAIS is to suspend with electro-magnetic actuators a scientific payload, isolating it from the vibrating stator. The MAIS's vibration isolation capability is frequency-dependent and a decrease of vibration of about 40dB can be attained. The MAIS can accommodate 20kg of scientific payload or sample unit, and provide 30W of power and 1Mbps of data transmission. The MAIS is developed to support microgravity scientific experiments on manned platforms in low earth orbit, in order to meet the scientific requirements for fluid physics, materials science, and fundamental physics investigations, which usually need a very quiet environment, increasing their chances of success and their scientific outcomes. The results of scientific experiments and technology tests obtained with the MAIS will be used to improve future space based research. As the suspension force acting on the payload is very small, the MAIS can only be operative and tested in a weightless environment. The 'Deutsches Zentrum für Luft- und Raumfahrt e.V.' (DLR, German Aerospace Centre) granted a flight opportunity to the MAIS experiment to be tested during its 27th parabolic flight campaign of September 2015 performed on the A310 ZERO-G aircraft managed by the French company Novespace, a subsidiary of the 'Centre National d'Etudes Spatiales' (CNES, French Space Agency). The experiment results confirmed that the 6 degrees of freedom motion control technique was effective, and that the vibration isolation performance fulfilled perfectly the expectations based on theoretical analyses and simulations. This paper will present the design of the MAIS and the experiment results obtained during the

  13. Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests

    International Nuclear Information System (INIS)

    Nho, Ki Man; Kim, Wang Bae

    1998-01-01

    The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO 2 gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for dew point rate of rise of Wolsung Unit 2. It was found that the response of the dew point depends on the moisture injection rate, CO 2 gas flow rate and the leak location. The test showed that Candu 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS CO 2 flow rate is approximated. (author)

  14. Intelligent buildings, automatic fire alarm and fire-protection control system

    International Nuclear Information System (INIS)

    Tian Deyuan

    1999-01-01

    The author describes in brief the intelligent buildings, and the automatic fire alarm and fire-protection control system. On the basis of the four-bus, three-bus and two-bus, a new transfer technique was developed

  15. Associations Between the Self-Reported Frequency of Hearing Chemical Alarms in Theater and Visuospatial Function in Gulf War Veterans.

    Science.gov (United States)

    Chao, Linda L

    2016-10-01

    The aim of this study was to examine the relationship between the self-reported frequencies of hearing chemical alarms during deployment and visuospatial function in Gulf War (GW) veterans. The relationship between the self-reported frequency of hearing chemical alarms, neurobehavioral, and volumetric brain imaging data was examined with correlational, regression, and mediation analyses. The self-reported frequency of hearing chemical alarms was inversely associated with and significantly predicted performance on a visuospatial task (ie, Block Design) over and above potentially confounding variables, including concurrent, correlated GW-related exposures. This effect was partially mediated by the relationship between hearing chemical alarms and lateral occipital cortex volume. Exposure to substances that triggered chemical alarms during GW deployment likely had adverse effects on veterans' brain structure and function, warranting further investigation of whether these GW veterans are at an increased risk for dementia.

  16. Intelligent Smoke Alarm System with Wireless Sensor Network Using ZigBee

    Directory of Open Access Journals (Sweden)

    Qin Wu

    2018-01-01

    Full Text Available The conflagration of fire is still a serious problem caused by humans, and houses are at a high risk of fire. Recently, people have used smoke alarms which only have one sensor to detect fire. Smoke is emitted in several forms in daily life. A single sensor is not a reliable way to detect fire. With the rapid advancement in Internet technology, people can monitor their houses remotely to determine the current condition of the house. This paper introduces an intelligent smoke alarm system that uses ZigBee transmission technology to build a wireless network, uses random forest to identify smoke, and uses E-charts for data visualization. By combining the real-time dynamic changes of various environmental factors, compared to the traditional smoke alarm, the accuracy and controllability of the fire warning are increased, and the visualization of the data enables users to monitor the room environment more intuitively. The proposed system consists of a smoke detection module, a wireless communication module, and intelligent identification and data visualization module. At present, the collected environmental data can be classified into four statuses, that is, normal air, water mist, kitchen cooking, and fire smoke. Reducing the frequency of miscalculations also means improving the safety of the person and property of the user.

  17. From nestling calls to fledgling silence: adaptive timing of change in response to aerial alarm calls.

    Science.gov (United States)

    Magrath, Robert D; Platzen, Dirk; Kondo, Junko

    2006-09-22

    Young birds and mammals are extremely vulnerable to predators and so should benefit from responding to parental alarm calls warning of danger. However, young often respond differently from adults. This difference may reflect: (i) an imperfect stage in the gradual development of adult behaviour or (ii) an adaptation to different vulnerability. Altricial birds provide an excellent model to test for adaptive changes with age in response to alarm calls, because fledglings are vulnerable to a different range of predators than nestlings. For example, a flying hawk is irrelevant to a nestling in a enclosed nest, but is dangerous to that individual once it has left the nest, so we predict that young develop a response to aerial alarm calls to coincide with fledging. Supporting our prediction, recently fledged white-browed scrubwrens, Sericornis frontalis, fell silent immediately after playback of their parents' aerial alarm call, whereas nestlings continued to calling despite hearing the playback. Young scrubwrens are therefore exquisitely adapted to the changing risks faced during development.

  18. Fingers' vibration transmission and grip strength preservation performance of vibration reducing gloves.

    Science.gov (United States)

    Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P

    2018-01-01

    The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused

  19. No more moody mornings : Alarm clock anticipates sleepers' emotions

    NARCIS (Netherlands)

    Wensveen, S.; Overbeeke, K.; Van Kasteren, J.

    2002-01-01

    More eloquent alternatives to the harsh tones of the oldfashioned alarm-clock bells abound, including a newsreaders voice summing up last nights disasters, or a tape of your favourite early morning music. Still, getting out of bed has its difficult moments. All this could well change in the near

  20. Impaired behavioural response to alarm substance in rainbow trout exposed to copper nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Sovová, Tereza [Ecotoxicology Research and Innovation Centre, School of Biomedical and Biological Sciences, Plymouth University, Devon (United Kingdom); Department of Environmental Chemistry, Faculty of Environmental Technology, Institute of Chemical Technology, Prague (Czech Republic); Boyle, David, E-mail: david.boyle@ualberta.ca [Ecotoxicology Research and Innovation Centre, School of Biomedical and Biological Sciences, Plymouth University, Devon (United Kingdom); Sloman, Katherine A. [School of Science, University of the West of Scotland, Paisley (United Kingdom); Vanegas Pérez, Cecilia [Ecotoxicology Research and Innovation Centre, School of Biomedical and Biological Sciences, Plymouth University, Devon (United Kingdom); Laboratory of Animal Ecophysiology and Aquatic Ecotoxicology, National Autonomous University of Mexico, Mexico City (Mexico); Handy, Richard D. [Ecotoxicology Research and Innovation Centre, School of Biomedical and Biological Sciences, Plymouth University, Devon (United Kingdom)

    2014-07-01

    Highlights: • Copper nanoparticles impaired the behavioural response of trout to alarm substance. • This effect appeared to be greater than in trout exposed to copper sulphate. • Toxicity was mediated by interaction of materials at external surfaces of fish. • Copper nanoparticles did not affect the morphology of the olfactory rosette. • Copper nanoparticles caused a change in glutathione status in brains of fish. - Abstract: To date, studies of the toxicity of engineered nanoparticles (NPs) in fish have not fully considered effects on olfactory-mediated behaviours, despite their ecological importance. In this study the effects of copper NPs (Cu NPs) on the anti-predator behavioural responses of juvenile rainbow trout (Oncorhynchus mykiss) to trout alarm substance was investigated. Individual fish were exposed for 12 h to a control (no added Cu), 50 μg l⁻¹ of Cu as Cu NPs, or 50 μg l⁻¹ Cu as CuSO₄, after which fish behaviours were analyzed in 10 min periods before and after the addition of the alarm substance stimulus. The response of control fish to deionised water (negative control, no alarm substance stimulus) was also analyzed. The alarm substance elicited a behavioural response in the control fish characterized by an immediate freeze response and the slower resumption of swimming activity compared to negative controls exposed to the sham deionised water stimuli. In fish exposed to Cu NPs, the behavioural response to alarm substance was eliminated, with no significant difference in behaviours compared to negative controls. In comparison, exposure to 50 μg l⁻¹ Cu as CuSO₄ decreased, but did not eliminate the response of fish to alarm substance, which indicated a significantly greater effect of Cu NPs on olfactory mediated behaviours than of the equivalent concentration of Cu as CuSO₄. Measurement of total Cu concentrations in the tissues of fish demonstrated no significant accumulation of Cu from any treatment in gill, liver or brain

  1. Flow-induced vibration phenomenon in a Mark III TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C K; Whittemore, W L; Kim, B S; Lee, J B; Blevins, R D; Burton, T E [Korea Atomic Energy Research Institute, Seoul (Korea, Republic of); General Atomic Company, San Diego, CA (United States)

    1976-07-01

    The Mark III TRIGA reactor with hexagonal fuel spacing is capable of operating at 2.0 MW. The Mark III at San Diego operated without core cooling problems or vibration at power levels up to 2.0 MW. All Mark III reactors have operated trouble-free up to 1.0 MW. The Mark III TRIGA in Korea was installed in 1972 and operated many months without trouble at 2.0 MW. During this period core changes including addition of new fuel were made. Eighteen months after startup, a coolant flow-induced vibration was observed for the first time at a power of 1.5 MW. A lengthy series of tests showed that it was not possible to establish a core configuration that permitted vibration-free operation for power levels in the range 1.5 - 2.0 MW. Observations during the tests confirmed that standing waves in the reactor tank water coupled the source within the core to the shield structure and surrounding building. Analysis of the data indicates strongly that the source of the vibration is the creation and collapse of bubbles with the core acting as a resonator. A substantially increased flow of coolant through the upper grid plate is expected to eliminate the vibration phenomenon and permit trouble-free operation at power up to 2.0 MW. In an attempt to seek a remedy, both GAC and KAERI have independently developed designs for upper grid plates. KAERI has constructed and installed an interim version of the standard grid plate which was calculated to provide 25% more coolant flow and mounted high so as to provide less restriction to flow around the upper fittings of the fuel elements. A substantial reduction in vibration was observed. No vibration was observed at any power up to 2.0 MW with cooling water at or below 20 C. A slight vibration at 1.8 MW occurred for higher cooling temperatures. The GAC grid plate design provides not only for increasing the flow area but also for streamlining the flow surfaces on the grid plate and possibly also on the top fittings of the fuel elements. It is

  2. Flow-induced vibration phenomenon in a Mark III TRIGA reactor

    International Nuclear Information System (INIS)

    Lee, C.K.; Whittemore, W.L.; Kim, B.S.; Lee, J.B.; Blevins, R.D.; Burton, T.E.

    1976-01-01

    The Mark III TRIGA reactor with hexagonal fuel spacing is capable of operating at 2.0 MW. The Mark III at San Diego operated without core cooling problems or vibration at power levels up to 2.0 MW. All Mark III reactors have operated trouble-free up to 1.0 MW. The Mark III TRIGA in Korea was installed in 1972 and operated many months without trouble at 2.0 MW. During this period core changes including addition of new fuel were made. Eighteen months after startup, a coolant flow-induced vibration was observed for the first time at a power of 1.5 MW. A lengthy series of tests showed that it was not possible to establish a core configuration that permitted vibration-free operation for power levels in the range 1.5 - 2.0 MW. Observations during the tests confirmed that standing waves in the reactor tank water coupled the source within the core to the shield structure and surrounding building. Analysis of the data indicates strongly that the source of the vibration is the creation and collapse of bubbles with the core acting as a resonator. A substantially increased flow of coolant through the upper grid plate is expected to eliminate the vibration phenomenon and permit trouble-free operation at power up to 2.0 MW. In an attempt to seek a remedy, both GAC and KAERI have independently developed designs for upper grid plates. KAERI has constructed and installed an interim version of the standard grid plate which was calculated to provide 25% more coolant flow and mounted high so as to provide less restriction to flow around the upper fittings of the fuel elements. A substantial reduction in vibration was observed. No vibration was observed at any power up to 2.0 MW with cooling water at or below 20 C. A slight vibration at 1.8 MW occurred for higher cooling temperatures. The GAC grid plate design provides not only for increasing the flow area but also for streamlining the flow surfaces on the grid plate and possibly also on the top fittings of the fuel elements. It is

  3. Design for safety : A new service for alarming and informing the population in case of emergency

    NARCIS (Netherlands)

    Jagtman, H.M.

    2012-01-01

    In case of emergencies the population in danger should be alarmed so individuals can take action to get or remain out of danger. For alarming the population the means available are limited. Many countries have outdoor sirens. They operability however is limited since the siren has only one implicit

  4. Use of alarm features in referral of febrile children to the emergency department : an observational study

    NARCIS (Netherlands)

    van Ierland, Yvette; Elshout, Gijs; Moll, Henritte A.; Nijman, Ruud G.; Vergouwe, Yvonne; van der Lei, Johan; Berger, Marjolein Y.; Oostenbrink, Rianne

    Background The diagnostic value of alarm features of serious infections in low prevalence settings is unclear. Aim To explore to what extent alarm features play a role in referral to the emergency department (ED) by GPs who face a febrile child during out-of-hours care. Design and setting

  5. Laboratory evaluation of a vibrating orifice monodisperse aerosol generator

    International Nuclear Information System (INIS)

    Everitt, N.M.; Snelling, K.W.

    1985-02-01

    The Berglund-Liu vibrating orifice aerosol generator is capable of producing monodisperse particles in the diameter range 5 to 50 μm. Experiments have been carried out to set up and evaluate such a generator for the preparation of standard liquid (olive oil) and solid (methylene blue) aerosols in the size range 8 to 13 μm. Modifications have been made to the apparatus to improve its performance and increase its particle output. (author)

  6. Integrating Oil Debris and Vibration Measurements for Intelligent Machine Health Monitoring. Degree awarded by Toledo Univ., May 2002

    Science.gov (United States)

    Dempsey, Paula J.

    2003-01-01

    A diagnostic tool for detecting damage to gears was developed. Two different measurement technologies, oil debris analysis and vibration were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig. An oil debris sensor and the two vibration algorithms were adapted as the diagnostic tools. An inductance type oil debris sensor was selected for the oil analysis measurement technology. Gear damage data for this type of sensor was limited to data collected in the NASA Glenn test rigs. For this reason, this analysis included development of a parameter for detecting gear pitting damage using this type of sensor. The vibration data was used to calculate two previously available gear vibration diagnostic algorithms. The two vibration algorithms were selected based on their maturity and published success in detecting damage to gears. Oil debris and vibration features were then developed using fuzzy logic analysis techniques, then input into a multi sensor data fusion process. Results show combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spur gears. As a result of this research, this new diagnostic tool has significantly improved detection of gear damage in the NASA Glenn Spur Gear Fatigue Rigs. This research also resulted in several other findings that will improve the development of future health monitoring systems. Oil debris analysis was found to be more reliable than vibration analysis for detecting pitting fatigue failure of gears and is capable of indicating damage progression. Also, some vibration algorithms are as sensitive to operational effects as they

  7. Variation in the behavioral responses of Budgerigars Melopsittacus undulatus to an alarm call in relation to sex and season

    Directory of Open Access Journals (Sweden)

    Gérard Nicolas

    2004-06-01

    Full Text Available In the Budgerigar Melopsittacus undulatus, the significance of a conspecific alarm call was investigated in two seasons, winter and spring. Two qualitatively different behavioral responses were displayed by the receivers in reply to playbacks: call(s and/or taking flight(s. The comparative analysis of the number of birds responding to the alarm and to the control signals revealed two major facts: 1 in both seasons, the responses to the alarm signal were only observed for females, not for males, 2 qualitatively, females exhibited a great inter-season variability in their behavioral responses to the hearing of an alarm call. In winter, the females were more predisposed to emit acoustic responses while in spring they mainly took flight.O significado de um grito de alarme do Periquito-australiano Melopsittacus undulatus foi investigado em duas estações, inverno e primavera. Duas reações comportamentais, qualitativamente diferentes, foram apresentadas pelos receptores em resposta ao play-back: grito(s e/ou vôo(s. A análise comparativa do número de aves respondendo ao grito de alarme e aos sinais de controle revelou dois fatos principais: 1 em ambas as estações, as respostas ao grito de alarme foram observadas somente para as fêmeas, não para os machos, 2 qualitativamente, as fêmeas mostraram uma grande variação estacional nas suas respostas comportamentais à escuta de um grito de alarme. No inverno, as fêmeas eram mais predispostas a emitir uma resposta acústica, enquanto na primavera elas geralmente levantavam vôo.

  8. Dosimetric properties of the pocket alarm dosimeter type Alnor RAD 21L, RAD 21H, RAD 22

    International Nuclear Information System (INIS)

    Hauser, M.; Burgkhardt, B.; Piesch, E.

    1981-02-01

    In personnel monitoring pocket dosimeters with build-in alarm devices are increasingly in use. The report presents results of a test performed at Karlsruhe for the pocket dose and alarm meter type Alnor RAD 21L, RAD 21H, RAD 22. The properties investigated are above all linearity and reproducibility of the dose reading as well as of the acoustic alarm indication, dependence of the dose reading on the photon energy, the direction of the radiation incidence, the dose rate, the temperature, operational characteristic of the batteries. (orig.) [de

  9. Optimal design of a beam-based dynamic vibration absorber using fixed-points theory

    Science.gov (United States)

    Hua, Yingyu; Wong, Waion; Cheng, Li

    2018-05-01

    The addition of a dynamic vibration absorber (DVA) to a vibrating structure could provide an economic solution for vibration suppressions if the absorber is properly designed and located onto the structure. A common design of the DVA is a sprung mass because of its simple structure and low cost. However, the vibration suppression performance of this kind of DVA is limited by the ratio between the absorber mass and the mass of the primary structure. In this paper, a beam-based DVA (beam DVA) is proposed and optimized for minimizing the resonant vibration of a general structure. The vibration suppression performance of the proposed beam DVA depends on the mass ratio, the flexural rigidity and length of the beam. In comparison with the traditional sprung mass DVA, the proposed beam DVA shows more flexibility in vibration control design because it has more design parameters. With proper design, the beam DVA's vibration suppression capability can outperform that of the traditional DVA under the same mass constraint. The general approach is illustrated using a benchmark cantilever beam as an example. The receptance theory is introduced to model the compound system consisting of the host beam and the attached beam-based DVA. The model is validated through comparisons with the results from Abaqus as well as the Transfer Matrix method (TMM) method. Fixed-points theory is then employed to derive the analytical expressions for the optimum tuning ratio and damping ratio of the proposed beam absorber. A design guideline is then presented to choose the parameters of the beam absorber. Comparisons are finally presented between the beam absorber and the traditional DVA in terms of the vibration suppression effect. It is shown that the proposed beam absorber can outperform the traditional DVA by following this proposed guideline.

  10. Shock and vibration tests of uranium mononitride fuel pellets for a space power nuclear reactor

    Science.gov (United States)

    Adams, D. W.

    1972-01-01

    Shock and vibration tests were conducted on cylindrically shaped, depleted, uranium mononitride (UN) fuel pellets. The structural capabilities of the pellets were determined under exposure to shock and vibration loading which a nuclear reactor may encounter during launching into space. Various combinations of diametral and axial clearances between the pellets and their enclosing structures were tested. The results of these tests indicate that for present fabrication of UN pellets, a diametral clearance of 0.254 millimeter and an axial clearance of 0.025 millimeter are tolerable when subjected to launch-induced loads.

  11. To stay or to go? Balancing the risk of reprocessing plant control room evacuation following a criticality alarm

    International Nuclear Information System (INIS)

    Love, Suzanne; McCrindle, David; Harris, Neil; Haworth, Justin

    2003-01-01

    Following a criticality alarm within the Magnox Separation Plant at Sellafield, there is a conflict of interest between the risks associated with complete evacuation versus continued manning of the control room. The historic emergency response policy would be to completely evacuate the control room upon a criticality alarm. If, however, the alarm was found to be false, the inevitable loss in control over the plant could have environmental, operational and radiological release consequences. Maintaining control room manning following a genuine alarm might, however, result in an avoidable high dose to an operator. Based upon the estimated dose equivalent to a control room operator for a range of criticality incident morphologies a risk analysis was undertaken. The results indicate that the differential risk between an operator who evacuates immediately and an operator who remains for a short time to complete diagnostic checks is very small. As a consequence a new emergency policy was therefore developed on plant which results in a relatively low risk to control room operators, but still allows control over the plant to be retained following a false criticality alarm. (author)

  12. Design of reactor alarm instrument based on SOPC

    International Nuclear Information System (INIS)

    Li Meng; Lu Yi; Rong Ru

    2008-01-01

    The design of embedded alarm instrument in reactors based on Nios II CPU is introduced in this paper. This design uses the SOPC technology based on the Cyclone series FPGA as a digital bench, and connects the MPU and drivers and interface of times, RS232, sdram,and etc. into a FPGA chip. It is proved that the system achieves the design goals in primary experimentation. (authors)

  13. Coupled thermal, structural and vibrational analysis of a hypersonic engine for flight test

    Energy Technology Data Exchange (ETDEWEB)

    Sook-Ying, Ho [Defence Science and Technology Organisation, SA (Australia); Paull, A. [Queensland Univ., Dept. of Mechanical Engineering (Australia)

    2006-07-15

    This paper describes a relatively simple and quick method for implementing aerodynamic heating models into a finite element code for non-linear transient thermal-structural and thermal-structural-vibrational analyses of a Mach 10 generic HyShot scram-jet engine. The thermal-structural-vibrational response of the engine was studied for the descent trajectory from 60 to 26 km. Aerodynamic heating fluxes, as a function of spatial position and time for varying trajectory points, were implemented in the transient heat analysis. Additionally, the combined effect of varying dynamic pressure and thermal loads with altitude was considered. This aero-thermal-structural analysis capability was used to assess the temperature distribution, engine geometry distortion and yielding of the structural material due to aerodynamic heating during the descent trajectory, and for optimising the wall thickness, nose radius of leading edge, etc. of the engine intake. A structural vibration analysis was also performed following the aero-thermal-structural analysis to determine the changes in natural frequencies of the structural vibration modes that occur at the various temperatures associated with the descent trajectory. This analysis provides a unique and relatively simple design strategy for predicting and mitigating the thermal-structural-vibrational response of hypersonic engines. (authors)

  14. A laser-optical sensor system for blade vibration detection of high-speed compressors

    Science.gov (United States)

    Neumann, Mathias; Dreier, Florian; Günther, Philipp; Wilke, Ulrich; Fischer, Andreas; Büttner, Lars; Holzinger, Felix; Schiffer, Heinz-Peter; Czarske, Jürgen

    2015-12-01

    Improved efficiency as well as increased lifetime of turbines and compressors are important goals in turbomachinery development. A significant enhancement to accomplish these aims can be seen in online monitoring of the operating parameters of the machines. During the operation of compressors it is of high interest to predict critical events like flutter or stall which can be achieved by observing blade deformations and vibrations. We have developed a laser Doppler distance sensor (LDDS), which is capable of simultaneously measuring the radial blade expansions, the circumferential blade deflections as well as the circumferential velocities of the rotor blade tips. As a result, an increase of blade vibrations is measured before stall at characteristic frequencies. While the detected vibration frequencies and the vibration increase are in agreement with the measurement results of a commercial capacitive blade tip timing system, the measured values of the vibration amplitudes differ by a factor of three. This difference can be mainly attributed to the different measurement locations and to the different measurement approaches. Since the LDDS is applicable to metal as well as ceramic, carbon-fiber and glass-fiber reinforced composite blades, a universally applicable sensor system for stall prediction and status monitoring is presented.

  15. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    International Nuclear Information System (INIS)

    Hu, Zhengyi; Yuan, Xunhua; Pollmann, Steven I; Nikolov, Hristo N; Holdsworth, David W; Welch, Ian

    2015-01-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice. (paper)

  16. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    Science.gov (United States)

    Hu, Zhengyi; Welch, Ian; Yuan, Xunhua; Pollmann, Steven I.; Nikolov, Hristo N.; Holdsworth, David W.

    2015-08-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice.

  17. Technical guide to criticality alarm system design

    International Nuclear Information System (INIS)

    Greenfield, B.

    2009-01-01

    An instructional manual was created to guide criticality safety engineers through the technical aspects of designing a criticality alarm system (CAS) for Dept. of Energy (DOE) hazard class 1 and 2 facilities. The manual was structured such that it can be used by engineers designing completely new systems and by those who are working with existing facilities. Major design tasks are thoroughly analyzed to provide concise direction for how to complete the analysis. Regulatory and technical performance requirements were both addressed. (authors)

  18. The sound of danger: threat sensitivity to predator vocalizations, alarm calls, and novelty in gulls.

    Directory of Open Access Journals (Sweden)

    Sarah A MacLean

    Full Text Available The threat sensitivity hypothesis predicts that organisms will evaluate the relative danger of and respond differentially to varying degrees of predation threat. Doing so allows potential prey to balance the costs and benefits of anti-predator behaviors. Threat sensitivity has undergone limited testing in the auditory modality, and the relative threat level of auditory cues from different sources is difficult to infer across populations when variables such as background risk and experience are not properly controlled. We experimentally exposed a single population of two sympatric gull species to auditory stimuli representing a range of potential threats in order to compare the relative threat of heterospecific alarm calls, conspecific alarms calls, predator vocalizations, and novel auditory cues. Gulls were able to discriminate among a diverse set of threat indicators and respond in a graded manner commensurate with the level of threat. Vocalizations of two potential predators, the human voice and bald eagle call, differed in their threat level compared to each other and to alarm calls. Conspecific alarm calls were more threatening than heterospecfic alarm calls to the larger great black-backed gull, but the smaller herring gull weighed both equally. A novel cue elicited a response intermediate between known threats and a known non-threat in herring gulls, but not great black-backed gulls. Our results show that the relative threat level of auditory cues from different sources is highly species-dependent, and that caution should be exercised when comparing graded and threshold threat sensitive responses.

  19. An adaptive left–right eigenvector evolution algorithm for vibration isolation control

    International Nuclear Information System (INIS)

    Wu, T Y

    2009-01-01

    The purpose of this research is to investigate the feasibility of utilizing an adaptive left and right eigenvector evolution (ALREE) algorithm for active vibration isolation. As depicted in the previous paper presented by Wu and Wang (2008 Smart Mater. Struct. 17 015048), the structural vibration behavior depends on both the disturbance rejection capability and mode shape distributions, which correspond to the left and right eigenvector distributions of the system, respectively. In this paper, a novel adaptive evolution algorithm is developed for finding the optimal combination of left–right eigenvectors of the vibration isolator, which is an improvement over the simultaneous left–right eigenvector assignment (SLREA) method proposed by Wu and Wang (2008 Smart Mater. Struct. 17 015048). The isolation performance index used in the proposed algorithm is defined by combining the orthogonality index of left eigenvectors and the modal energy ratio index of right eigenvectors. Through the proposed ALREE algorithm, both the left and right eigenvectors evolve such that the isolation performance index decreases, and therefore one can find the optimal combination of left–right eigenvectors of the closed-loop system for vibration isolation purposes. The optimal combination of left–right eigenvectors is then synthesized to determine the feedback gain matrix of the closed-loop system. The result of the active isolation control shows that the proposed method can be utilized to improve the vibration isolation performance compared with the previous approaches

  20. Satellite Search and Rescue System Studies: Alarm and Position Reporting.

    Science.gov (United States)

    alarm and position reporting ( ALPR ) techniques, and the operational or planned spacecraft which might be available for piggybacking the ALPR payload...Several system concepts were then developed to perform the ALPR functions. The candidates were screened and the preferred system concepts were chosen

  1. Micro-Vibration Performance Prediction of SEPTA24 Using SMeSim (RUAG Space Mechanism Simulator Tool)

    Science.gov (United States)

    Omiciuolo, Manolo; Lang, Andreas; Wismer, Stefan; Barth, Stephan; Szekely, Gerhard

    2013-09-01

    Scientific space missions are currently challenging the performances of their payloads. The performances can be dramatically restricted by micro-vibration loads generated by any moving parts of the satellites, thus by Solar Array Drive Assemblies too. Micro-vibration prediction of SADAs is therefore very important to support their design and optimization in the early stages of a programme. The Space Mechanism Simulator (SMeSim) tool, developed by RUAG, enhances the capability of analysing the micro-vibration emissivity of a Solar Array Drive Assembly (SADA) under a specified set of boundary conditions. The tool is developed in the Matlab/Simulink® environment throughout a library of blocks simulating the different components a SADA is made of. The modular architecture of the blocks, assembled by the user, and the set up of the boundary conditions allow time-domain and frequency-domain analyses of a rigid multi-body model with concentrated flexibilities and coupled- electronic control of the mechanism. SMeSim is used to model the SEPTA24 Solar Array Drive Mechanism and predict its micro-vibration emissivity. SMeSim and the return of experience earned throughout its development and use can now support activities like verification by analysis of micro-vibration emissivity requirements and/or design optimization to minimize the micro- vibration emissivity of a SADA.

  2. An engineering approach to knowledge-based systems, the alarm processing and diagnostic system

    International Nuclear Information System (INIS)

    Mah, E.; Damon, L.

    1992-01-01

    The number of alarms that may be initiated during transients or accidents in nuclear-generating control rooms may temporarily exceed an operator's ability to assimilate and respond. This phenomenon is characterized as Cognitive Overload. The Alarm Processing and Diagnostic System (APDS) was designed to deal with this problem through a unique and operationally sensitive method of alarm prioritization and filtration. The approach taken attempts to parallel the operator's situation assessment methodology when dealing with transient conditions. A strong criteria for the development methodology employed was its ultimate acceptance by parties engaged in the operation of nuclear power facilities. As such, the methodology used had to be easily understood and consistent with the acceptance standards of nuclear power. This necessitated the verifiable practices found in engineering design. While APDS remains rooted in artificial intelligence or expert systems, it goes beyond the paradigm of rules and inferencing to an object-oriented structure that allows traditional and well-documented engineering-based decision methods to be applied. These features have important consequences when considering final acceptance, implementation, and maintenance. 3 refs., 1 tab

  3. Impaired behavioural response to alarm substance in rainbow trout exposed to copper nanoparticles

    International Nuclear Information System (INIS)

    Sovová, Tereza; Boyle, David; Sloman, Katherine A.; Vanegas Pérez, Cecilia; Handy, Richard D.

    2014-01-01

    Highlights: • Copper nanoparticles impaired the behavioural response of trout to alarm substance. • This effect appeared to be greater than in trout exposed to copper sulphate. • Toxicity was mediated by interaction of materials at external surfaces of fish. • Copper nanoparticles did not affect the morphology of the olfactory rosette. • Copper nanoparticles caused a change in glutathione status in brains of fish. - Abstract: To date, studies of the toxicity of engineered nanoparticles (NPs) in fish have not fully considered effects on olfactory-mediated behaviours, despite their ecological importance. In this study the effects of copper NPs (Cu NPs) on the anti-predator behavioural responses of juvenile rainbow trout (Oncorhynchus mykiss) to trout alarm substance was investigated. Individual fish were exposed for 12 h to a control (no added Cu), 50 μg l −1 of Cu as Cu NPs, or 50 μg l −1 Cu as CuSO 4 , after which fish behaviours were analyzed in 10 min periods before and after the addition of the alarm substance stimulus. The response of control fish to deionised water (negative control, no alarm substance stimulus) was also analyzed. The alarm substance elicited a behavioural response in the control fish characterized by an immediate freeze response and the slower resumption of swimming activity compared to negative controls exposed to the sham deionised water stimuli. In fish exposed to Cu NPs, the behavioural response to alarm substance was eliminated, with no significant difference in behaviours compared to negative controls. In comparison, exposure to 50 μg l −1 Cu as CuSO 4 decreased, but did not eliminate the response of fish to alarm substance, which indicated a significantly greater effect of Cu NPs on olfactory mediated behaviours than of the equivalent concentration of Cu as CuSO 4 . Measurement of total Cu concentrations in the tissues of fish demonstrated no significant accumulation of Cu from any treatment in gill, liver or brain

  4. Vibration analysis and vibration damage assessment in nuclear and process equipment

    International Nuclear Information System (INIS)

    Pettigrew, M.J.; Taylor, C.E.; Fisher, N.J.; Yetisir, M.; Smith, B.A.W.

    1997-01-01

    Component failures due to excessive flow-induced vibration are still affecting the performance and reliability of process and nuclear components. The purpose of this paper is to discuss flow-induced vibration analysis and vibration damage prediction. Vibration excitation mechanisms are described with particular emphasis on fluid elastic instability. The dynamic characteristics of process and power equipment are explained. The statistical nature of some parameters, in particular support conditions, is discussed. The prediction of fretting-wear damage is approached from several points-of-view. An energy approach to formulate fretting-wear damage is proposed. (author)

  5. Orthos, an alarm system for the ALICE DAQ operations

    Science.gov (United States)

    Chapeland, Sylvain; Carena, Franco; Carena, Wisla; Chibante Barroso, Vasco; Costa, Filippo; Denes, Ervin; Divia, Roberto; Fuchs, Ulrich; Grigore, Alexandru; Simonetti, Giuseppe; Soos, Csaba; Telesca, Adriana; Vande Vyvre, Pierre; von Haller, Barthelemy

    2012-12-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector studying the physics of strongly interacting matter and the quark-gluon plasma at the CERN LHC (Large Hadron Collider). The DAQ (Data Acquisition System) facilities handle the data flow from the detectors electronics up to the mass storage. The DAQ system is based on a large farm of commodity hardware consisting of more than 600 devices (Linux PCs, storage, network switches), and controls hundreds of distributed hardware and software components interacting together. This paper presents Orthos, the alarm system used to detect, log, report, and follow-up abnormal situations on the DAQ machines at the experimental area. The main objective of this package is to integrate alarm detection and notification mechanisms with a full-featured issues tracker, in order to prioritize, assign, and fix system failures optimally. This tool relies on a database repository with a logic engine, SQL interfaces to inject or query metrics, and dynamic web pages for user interaction. We describe the system architecture, the technologies used for the implementation, and the integration with existing monitoring tools.

  6. Orthos, an alarm system for the ALICE DAQ operations

    International Nuclear Information System (INIS)

    Chapeland, Sylvain; Carena, Franco; Carena, Wisla; Chibante Barroso, Vasco; Costa, Filippo; Divia, Roberto; Fuchs, Ulrich; Grigore, Alexandru; Simonetti, Giuseppe; Soos, Csaba; Telesca, Adriana; Vande Vyvre, Pierre; Von Haller, Barthelemy; Denes, Ervin

    2012-01-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector studying the physics of strongly interacting matter and the quark-gluon plasma at the CERN LHC (Large Hadron Collider). The DAQ (Data Acquisition System) facilities handle the data flow from the detectors electronics up to the mass storage. The DAQ system is based on a large farm of commodity hardware consisting of more than 600 devices (Linux PCs, storage, network switches), and controls hundreds of distributed hardware and software components interacting together. This paper presents Orthos, the alarm system used to detect, log, report, and follow-up abnormal situations on the DAQ machines at the experimental area. The main objective of this package is to integrate alarm detection and notification mechanisms with a full-featured issues tracker, in order to prioritize, assign, and fix system failures optimally. This tool relies on a database repository with a logic engine, SQL interfaces to inject or query metrics, and dynamic web pages for user interaction. We describe the system architecture, the technologies used for the implementation, and the integration with existing monitoring tools.

  7. Vibration of hydraulic machinery

    CERN Document Server

    Wu, Yulin; Liu, Shuhong; Dou, Hua-Shu; Qian, Zhongdong

    2013-01-01

    Vibration of Hydraulic Machinery deals with the vibration problem which has significant influence on the safety and reliable operation of hydraulic machinery. It provides new achievements and the latest developments in these areas, even in the basic areas of this subject. The present book covers the fundamentals of mechanical vibration and rotordynamics as well as their main numerical models and analysis methods for the vibration prediction. The mechanical and hydraulic excitations to the vibration are analyzed, and the pressure fluctuations induced by the unsteady turbulent flow is predicted in order to obtain the unsteady loads. This book also discusses the loads, constraint conditions and the elastic and damping characters of the mechanical system, the structure dynamic analysis, the rotor dynamic analysis and the system instability of hydraulic machines, including the illustration of monitoring system for the instability and the vibration in hydraulic units. All the problems are necessary for vibration pr...

  8. Vibrations and Eigenvalues

    Indian Academy of Sciences (India)

    We make music by causing strings, membranes, or air columns to vibrate. Engineers design safe structures by control- ling vibrations. I will describe to you a very simple vibrating system and the mathematics needed to analyse it. The ideas were born in the work of Joseph-Louis Lagrange (1736–1813), and I begin by quot-.

  9. Fault Diagnosis using Audio and Vibration Signals in a Circulating Pump

    International Nuclear Information System (INIS)

    Henríquez, P; Alonso, J B; Ferrer, M A; Travieso, C M; Gómez, G

    2012-01-01

    This paper presents the use of audio and vibration signals in fault diagnosis of a circulating pump. The novelty of this paper is the use of audio signals acquired by microphones. The objective of this paper is to determine if audio signals are capable to distinguish between normal and different abnormal conditions in a circulating pump. In order to compare results, vibration signals are also acquired and analysed. Wavelet package is used to obtain the energies in different frequency bands from the audio and vibration signals. Neural networks are used to evaluate the discrimination ability of the extracted features between normal and fault conditions. The results show that information from sound signals can distinguish between normal and different faulty conditions with a success rate of 83.33%, 98% and 91.33% for each microphone respectively. These success rates are similar and even higher that those obtained from accelerometers (68%, 90.67% and 71.33% for each accelerometer respectively). Success rates also show that the position of microphones and accelerometers affects on the final results.

  10. Handbook Of Noise And Vibration

    International Nuclear Information System (INIS)

    1995-12-01

    This book is about noise and vibration. The first chapter has explanations of noise such as basic of sound, influence of noise, assessment of noise, measurement of prevention of noise and technology, case of noise measurement and soundproof. The second chapter describes vibration with outline, theory of vibration, interpretation of vibration, measurement for reduction of vibration, case of design of protection against vibration. It deals with related regulation and method of measurement.

  11. Emergency Response Capability Baseline Needs Assessment - Compliance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, John A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-09-01

    This document was prepared by John A. Sharry, LLNL Fire Marshal and Division Leader for Fire Protection and was reviewed by LLNL Emergency Management Department Head, James Colson. This document is the second of a two-part analysis on Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2016 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2016 BNA, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures. The 2013 BNA was approved by NNSA’s Livermore Field Office on January 22, 2014.

  12. Vibration mode and vibration shape under excitation of a three phase model transformer core

    Science.gov (United States)

    Okabe, Seiji; Ishigaki, Yusuke; Omura, Takeshi

    2018-04-01

    Structural vibration characteristics and vibration shapes under three-phase excitation of a archetype transformer core were investigated to consider their influences on transformer noise. Acoustic noise and vibration behavior were measured in a three-limb model transformer core. Experimental modal analysis by impact test was performed. The vibration shapes were measured by a laser scanning vibrometer at different exciting frequencies. Vibration amplitude of the core in out-of-plane direction were relatively larger than those in other two in-plane directions. It was consistent with the result that the frequency response function of the core in out-of-plane direction was larger by about 20 dB or more than those in in-plane directions. There were many vibration modes having bending deformation of limbs in out-of-plane direction. The vibration shapes of the core when excited at 50 Hz and 60 Hz were almost the same because the fundamental frequencies of the vibration were not close to the resonance frequencies. When excitation frequency was 69 Hz which was half of one of the resonance frequencies, the vibration shape changed to the one similar to the resonance vibration mode. Existence of many vibration modes in out-of-plane direction of the core was presumed to be a reason why frequency characteristics of magnetostriction and transformer noise do not coincide.

  13. Vibration Analysis of Beam and Block Precast Slab System due to Human Vibrations

    Science.gov (United States)

    Chik, T. N. T.; Kamil, M. R. H.; Yusoff, N. A.

    2018-04-01

    Beam and block precast slabs system are very efficient which generally give maximum structural performance where their voids based on the design of the unit soffit block allow a significant reduction of the whole slab self-weight. Initially for some combinations of components or the joint connection of the structural slab, this structural system may be susceptible to excessive vibrations that could effects the performance and also serviceability. Dynamic forces are excited from people walking and jumping which produced vibrations to the slab system in the buildings. Few studies concluded that human induced vibration on precast slabs system may be harmful to structural performance and mitigate the human comfort level. This study will investigate the vibration analysis of beam and block precast slab by using finite element method at the school building. Human activities which are excited from jumping and walking will induce the vibrations signal to the building. Laser Doppler Vibrometer (LDV) was used to measure the dynamic responses of slab towards the vibration sources. Five different points were assigned specifically where each of location will determine the behaviour of the entire slabs. The finite element analyses were developed in ABAQUS software and the data was further processed in MATLAB ModalV to assess the vibration criteria. The results indicated that the beam and block precast systems adequate enough to the vibration serviceability and human comfort criteria. The overall vibration level obtained was fell under VC-E curve which it is generally under the maximum permissible level of vibrations. The vibration level on the slab is acceptable within the limit that have been used by Gordon.

  14. AN APPROACH TO ALLEVIATE THE FALSE ALARM IN BUILDING CHANGE DETECTION FROM URBAN VHR IMAGE

    Directory of Open Access Journals (Sweden)

    J. Chen

    2016-06-01

    Full Text Available Building change detection from very-high-resolution (VHR urban remote sensing image frequently encounter the challenge of serious false alarm caused by different illumination or viewing angles in bi-temporal images. An approach to alleviate the false alarm in urban building change detection is proposed in this paper. Firstly, as shadows casted by urban buildings are of distinct spectral and shape feature, it adopts a supervised object-based classification technique to extract them in this paper. Secondly, on the opposite direction of sunlight illumination, a straight line is drawn along the principal orientation of building in every extracted shadow region. Starting from the straight line and moving toward the sunlight direction, a rectangular area is constructed to cover partial shadow and rooftop of each building. Thirdly, an algebra and geometry invariant based method is used to abstract the spatial topological relationship of the potential unchanged buildings from all central points of the rectangular area. Finally, based on an oriented texture curvature descriptor, an index is established to determine the actual false alarm in building change detection result. The experiment results validate that the proposed method can be used as an effective framework to alleviate the false alarm in building change detection from urban VHR image.

  15. Ship Vibrations

    DEFF Research Database (Denmark)

    Sørensen, Herman

    1997-01-01

    Methods for calculating natural frequencies for ship hulls and for plates and panels.Evaluation of the risk for inconvenient vibrations on board......Methods for calculating natural frequencies for ship hulls and for plates and panels.Evaluation of the risk for inconvenient vibrations on board...

  16. Aphid alarm pheromone as a cue for ants to locate aphid partners.

    Directory of Open Access Journals (Sweden)

    François J Verheggen

    Full Text Available The mutualistic relationships that occur between myrmecophilous aphids and ants are based on the rich food supply that honeydew represents for ants and on the protection they provide against aphid natural enemies. While aphid predators and parasitoids actively forage for oviposition sites by using aphid semiochemicals, scouts of aphid-tending ant species would also benefit from locating honeydew resources by orienting toward aphid pheromone sources. The present study aims to provide additional information on the use of Aphis fabae alarm pheromone, i.e. (E-β-farnesene (EβF, by ant scouts. The perception and behavioral impact of EβF on Lasius niger were investigated using electroantennography and two bio-assays measuring their attraction and orientation towards aphid semiochemicals. Pronounced electrical depolarizations were observed from L. niger scout antennae to stimulations of A. fabae alarm pheromone, while other sesquiterpenes elicited weak or no responses. L. niger scouts were significantly attracted toward EβF in a four-arm olfactometer, as well as in an two-choice bioassay. These laboratory results suggest for the first time that low amounts of aphid alarm pheromone can be used by L. niger scouts as a cue indicating the presence of aphid colonies and could therefore mediate the aphid-ant partnership in the field.

  17. Development of an alarm analysis system based on multi-level flow models for nuclear power plant

    International Nuclear Information System (INIS)

    Zhang Jiande; Yang Ming; Zhang Zhijian

    2008-01-01

    An alarm analysis system based on Multi-level Flow Models (MFM) was developed for a PWR NPP. By automatically identifying the primary root causes in complex fault situations, the workload of the operators can be reduced. In addition, because MFM also provides a set of graphical symbols that implies causalities, operators can confirm diagnosis results by semiotic analysis, and hence the understandability of the process of alarm analysis as well as the reliability of maintenance task can be increased. 19 cases of simulation data from RELAP5/MOD2 code were utilized for evaluating the performance of the proposed system. The simulation results show that the proposed alarm analysis system has a good ability to detect and diagnose accidents earlier in time before reactor trip. (authors)

  18. Potential Nematode Alarm Pheromone Induces Acute Avoidance in Caenorhabditis elegans.

    Science.gov (United States)

    Zhou, Ying; Loeza-Cabrera, Mario; Liu, Zheng; Aleman-Meza, Boanerges; Nguyen, Julie K; Jung, Sang-Kyu; Choi, Yuna; Shou, Qingyao; Butcher, Rebecca A; Zhong, Weiwei

    2017-07-01

    It is crucial for animal survival to detect dangers such as predators. A good indicator of dangers is injury of conspecifics. Here we show that fluids released from injured conspecifics invoke acute avoidance in both free-living and parasitic nematodes. Caenorhabditis elegans avoids extracts from closely related nematode species but not fruit fly larvae. The worm extracts have no impact on animal lifespan, suggesting that the worm extract may function as an alarm instead of inflicting physical harm. Avoidance of the worm extract requires the function of a cGMP signaling pathway that includes the cGMP-gated channel TAX-2/TAX-4 in the amphid sensory neurons ASI and ASK. Genetic evidence indicates that the avoidance behavior is modulated by the neurotransmitters GABA and serotonin, two common targets of anxiolytic drugs. Together, these data support a model that nematodes use a nematode-specific alarm pheromone to detect conspecific injury. Copyright © 2017 by the Genetics Society of America.

  19. The double-slit experiment and the time-reversed fire alarm

    International Nuclear Information System (INIS)

    Halabi, T.

    2010-01-01

    When both slits of the double-slit experiment are open, closing one paradoxically increases the detection rate at some points on the detection screen. Feynman famously warned that temptation to understand such a puzzling feature only draws into blind alleys. Nevertheless, we gain insight into this feature by drawing an analogy between the double-slit experiment and a time-reversed fire alarm. Much as closing the slit increases probability of a future detection, ruling out fire drill scenarios, having heard the fire alarm, increases probability of a past fire (using Bayesian inference). Classically, Bayesian inference is associated with computing probabilities of past events. We therefore identify this feature of the double-slit experiment with a time-reversed thermodynamic arrow. We believe that much of the enigma of quantum mechanics is simply due to some variation of time's arrow. In further support of this, we employ a plausible formulation of the thermodynamic arrow to derive an uncertainty in classical mechanics that is reminiscent of quantum uncertainty.

  20. Evaluation of vibration and vibration fatigue life for small bore pipe in nuclear power plants

    International Nuclear Information System (INIS)

    Wang Zhaoxi; Xue Fei; Gong Mingxiang; Ti Wenxin; Lin Lei; Liu Peng

    2011-01-01

    The assessment method of the steady state vibration and vibration fatigue life of the small bore pipe in the supporting system of the nuclear power plants is proposed according to the ASME-OM3 and EDF evaluation methods. The GGR supporting pipe system vibration is evaluated with this method. The evaluation process includes the filtration of inborn sensitivity, visual inspection, vibration tests, allowable vibration effective velocity calculation and vibration stress calculation. With the allowable vibration effective velocity calculated and the vibration velocity calculated according to the acceleration data tested, the filtrations are performed. The vibration stress at the welding coat is calculated with the spectrum method and compared with the allowable value. The response of the stress is calculated with the transient dynamic method, with which the fatigue life is evaluated with the Miners linear accumulation model. The vibration stress calculated with the spectrum method exceeds the allowable value, while the fatigue life calculated from the transient dynamic method is larger than the designed life with a big safety margin. (authors)