WorldWideScience

Sample records for vibration alarm capabilities

  1. Optimized Vibration Chamber for Landslide Sensory and Alarm System

    Science.gov (United States)

    Ismail, Eliza Sabira Binti; Hadi Habaebi, Mohamed; Daoud, Jamal I.; Rafiqul Islam, Md

    2017-11-01

    Landslide is one of natural hazard that is not unfamiliar disaster in Malaysia. Malaysia has experienced this disaster many times since 1969. This natural hazard has become a major research concern for Malaysian government when many people were injured badly and even had been killed. Many previous research works published in the open literature aimed at designing a system that could detect landslide in early stage before the landslide becomes catastrophic. This paper presents the early works on a major work-in-progress landslide early warning system for Malaysian environment. The aim of this system is to develop the most efficiently reliable cost-effective system in which slight earth movements are monitored continuously. The challenge this work aims at is to work with a low budget system that produces efficient performance. Hence, the material used is off-the-shelf. Early design optimization results of the vibration sensor used is quite promising detecting the slightest faint tremors, which are amplified using the best vibration chamber available. It is shown that the choice of proper pipe length and diameter dimensions in combination to a gravel to exaggerate the produced higher sensitivity level noise of 5 dB.

  2. Approaching Behaviour Monitor and Vibration Indication in Developing a General Moving Object Alarm System (GMOAS

    Directory of Open Access Journals (Sweden)

    Haiwei Dong

    2013-07-01

    Full Text Available People who suffer from hearing impairment caused by illness, age or extremely noisy environments are constantly in danger of being hit or knocked down by fast moving objects behind them when they have no companion or augmented sensory system to warn them. In this paper, we propose the General Moving Object Alarm System (GMOAS, a system focused on aiding the safe mobility of people under these circumstances. The GMOAS is a wearable haptic device that consists of two main subsystems: (i a moving object monitoring subsystem that uses laser range data to detect and track approaching objects, and (ii an alarm subsystem that warns the user of possibly dangerous approaching objects by triggering tactile vibrations on an “alarm necklace”. For moving object monitoring, we propose a simple yet efficient solution to monitor the approaching behavior of objects. Compared with previous work in motion detection and tracking, we are not interested in specific objects but any type of approaching object that might harm the user. To this extent, we define a boundary in the laser range data where the objects are monitored. Within this boundary a fan-shape grid is constructed to obtain an evenly distributed spatial partitioning of the data. These partitions are efficiently clustered into continuous objects which are then tracked through time using an object association algorithm based on updating a deviation matrix that represents angle, distance and size variations of the objects. The speed of the tracked objects is monitored throughout the algorithm. When the speed of an approaching object surpasses the safety threshold, the alarm necklace is triggered indicating the approaching direction of the fast moving object. The alarm necklace is equipped with three motors that can indicate five directions with respect to the user: left, back, right, left-back and right-back. We performed three types of outdoor experiments (object passing, approaching and crossing that

  3. Transformation of ground vibration signal for debris-flow monitoring and detection in alarm systems.

    Science.gov (United States)

    Abancó, Clàudia; Hürlimann, Marcel; Fritschi, Bruno; Graf, Christoph; Moya, José

    2012-01-01

    Debris flows are fast mass movements formed by a mix of water and solid materials, which occur in steep torrents, and are a source of high risks for human settlements. Geophones are widely used to detect the ground vibration induced by passing debris flows. However, the recording of geophone signals usually requires storing a huge amount of data, which leads to problems in storage capacity and power consumption. This paper presents a method to transform and simplify the signals measured by geophones. The key input parameter is the ground velocity threshold, which removes the seismic noise that is not related to debris flows. A signal conditioner was developed to implement the transformation and the ground velocity threshold was set by electrical resistors. The signal conditioner was installed at various European monitoring sites to test the method. Results show that data amount and power consumption can be greatly reduced without losing much information on the main features of the debris flows. However, the outcome stresses the importance of choosing a ground vibration threshold, which must be accurately calibrated. The transformation is also suitable to detect other rapid mass movements and to distinguish among different processes, which points to a possible implementation in alarm systems.

  4. Quantitative Index and Abnormal Alarm Strategy Using Sensor-Dependent Vibration Data for Blade Crack Identification in Centrifugal Booster Fans.

    Science.gov (United States)

    Chen, Jinglong; Sun, Hailiang; Wang, Shuai; He, Zhengjia

    2016-05-09

    Centrifugal booster fans are important equipment used to recover blast furnace gas (BFG) for generating electricity, but blade crack faults (BCFs) in centrifugal booster fans can lead to unscheduled breakdowns and potentially serious accidents, so in this work quantitative fault identification and an abnormal alarm strategy based on acquired historical sensor-dependent vibration data is proposed for implementing condition-based maintenance for this type of equipment. Firstly, three group dependent sensors are installed to acquire running condition data. Then a discrete spectrum interpolation method and short time Fourier transform (STFT) are applied to preliminarily identify the running data in the sensor-dependent vibration data. As a result a quantitative identification and abnormal alarm strategy based on compound indexes including the largest Lyapunov exponent and relative energy ratio at the second harmonic frequency component is proposed. Then for validation the proposed blade crack quantitative identification and abnormality alarm strategy is applied to analyze acquired experimental data for centrifugal booster fans and it has successfully identified incipient blade crack faults. In addition, the related mathematical modelling work is also introduced to investigate the effects of mistuning and cracks on the vibration features of centrifugal impellers and to explore effective techniques for crack detection.

  5. A vacuum microgripping tool with integrated vibration releasing capability

    Science.gov (United States)

    Rong, Weibin; Fan, Zenghua; Wang, Lefeng; Xie, Hui; Sun, Lining

    2014-08-01

    Pick-and-place of micro-objects is a basic task in various micromanipulation demands. Reliable releasing of micro-objects is usually disturbed due to strong scale effects. This paper focuses on a vacuum micro-gripper with vibration releasing functionality, which was designed and assembled for reliable micromanipulation tasks. Accordingly, a vibration releasing strategy of implementing a piezoelectric actuator on the vacuum microgripping tool is presented to address the releasing problem. The releasing mechanism was illustrated using a dynamic micro contact model. This model was developed via theoretical analysis, simulations and pull-off force measurement using atomic force microscopy. Micromanipulation experiments were conducted to verify the performance of the vacuum micro-gripper. The results show that, with the assistance of the vibration releasing, the vacuum microgripping tool can achieve reliable release of micro-objects. A releasing location accuracy of 4.5±0.5 μm and a successful releasing rate of around 100% (which is based on 110 trials) were achieved for manipulating polystyrene microspheres with radius of 35-100 μm.

  6. Enhancement of vibration desensitising capability of iterative algorithms for phase-shifting interferometers

    Science.gov (United States)

    Liu, Qian; Yuan, Daocheng; He, Huabin

    2017-11-01

    The sensitivity of phase-shifting interferometers (PSIs) to vibration impairs their application in unsteady environment. Iterative algorithms were developed to desensitise the effect of vibration on PSIs, but their desensitising capability is restricted by the estimated initial value. In this paper, a spatial carrier-assisted method is proposed, in which a wavefront phase retrieved from an additional spatial-carrier interferogram is used as the initial value. Because of the benefits of spatial carrier, vibration immunity and sign determination, iteration could converge to accurate value even when interferometers are under severe vibration. To reduce the possibility of transverse movement of the measured surface, subsampling strategy is further proposed to decrease the required tilt angle, with the additional benefit of decreasing the calculation time of iteration. Computer simulations and experiments are performed to verify the effectiveness of the proposed method. Results indicate that the vibration desensitising capability of an iterative algorithm is significantly enhanced by the proposed method. The proposed method improves the vibration desensitising capability with low cost and is thus highly compatible.

  7. Alarming atmospheres

    DEFF Research Database (Denmark)

    Højlund, Marie; Kinch, Sofie

    2014-01-01

    Nurses working in the Neuro-Intensive Care Unit at Aarhus University Hospital lack the tools to prepare children for the alarming atmosphere they will enter when visiting a hospitalised relative. The complex soundscape dominated by alarms and sounds from equipment is mentioned as the main stressor...

  8. The application of knowledge management and TRIZ for solving the safe shutdown capability of fire alarms in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chia-Nan; Chen, Hsin-Po; Hsueh, Ming-Hsien; Chin, Fong-Li [National Kaohsiung Univ. of Applied Sciences, Kaohsiung City, Taiwan (China). Dept. of Industrial Engineering and Management

    2017-11-15

    The Fukushima nuclear disaster in 2011 has raised widespread concern over the safety of nuclear power plants. This study employed knowledge management in conjunction with the Teoriya Resheniya Izobreatatelskih Zadatch (TRIZ) method in the formulation of a database to facilitate the evaluation of post-fire safe shutdown capability with the aim of safeguarding nuclear facilities in the event of fire. The proposed approach is meant to bring facilities in line with US Nuclear Regulatory Commission (NRC) standards. When implemented in a case study of an Asian nuclear power plant, our method proved highly effective in the detection of 22 cables that fell short of regulatory requirements, thereby reducing 850,000 paths to 0. This study could serve as reference for industry and academia in the development of systematic approaches to the upgrading of nuclear power plants.

  9. Display-And-Alarm Circuit For Accelerometer

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.

  10. Alarm System

    OpenAIRE

    GÖKTAŞ, H.Haldun; DALDAL, Nihat

    2010-01-01

    Remote management of several home and office appliances is a subject of growing interest and in recent years we have seen many systems providing such controls. In this study, we have developed a cellular phone based home/office remote controller equipped with power controllers, an alarm system, a voice memory and a back-up battery unit. In traditional PSTN based remote controllers, the user always has the possibility of line cuts due to fires or professional burglars cutting the wires before ...

  11. Analysis of vibroprotection characteristics of pneumatic relaxation seat suspension with capability of vibration energy recuperation

    Directory of Open Access Journals (Sweden)

    Lyashenko Mikhail

    2017-01-01

    Full Text Available This paper proposes mechanism and control algorithm for pneumatic relaxation system of suspension with vibration energy recuperation applied to standard vehicle operator seat (“Sibeko” company. Mathematical model of the seat pneumatic relaxation suspension with two additional air volumes was created. Pneumatic motor – recuperator activated by means of air flow from the one additional volume to another is installed in air piping between additional volumes. Computational research was made in Matlab/Simulink. Amplitude-frequency characteristics of transmission coefficient for standard and proposed suspensions were plotted for preliminary evaluation of vibration protection properties of seat suspension. Performed comparative analysis of amplitude-frequency characteristics shows that noticeable improvement of vibration protection properties of pneumatic relaxation suspension system with vibration energy recuperation in comparison with standard system both in region of resonance disturbances and in above-resonance region. Main ways for further improvement of vibration protection properties of proposed system were marked out.

  12. Introduction of quartz vibrating beam accelerometer technology providing capability for low cost, fully digital navigation

    Science.gov (United States)

    Holdren, F. V.; Norling, B. L.

    The proprietary 'Accelerex' vibrating-beam accelerometer is based on a specialized dual-tine quartz crystal resonator whose vibrating beam crystal employs two slender beams in a double-ended tuning fork-resembling geometry. This configuration furnishes perfect resonator dynamic balance, thereby obviating coupling and energy loss to the connecting structure. The slender beams of the crystal change frequency as a function of force in a way resembling the strings of a musical instrument. The Tactical Grade Accelerex system is optimized for low-cost tactical navigation and flight-control applications.

  13. Analysis of vibroprotection characteristics of pneumatic relaxation seat suspension with capability of vibration energy recuperation

    OpenAIRE

    Lyashenko Mikhail; Potapov Pavel; Iskaliev Azamat

    2017-01-01

    This paper proposes mechanism and control algorithm for pneumatic relaxation system of suspension with vibration energy recuperation applied to standard vehicle operator seat (“Sibeko” company). Mathematical model of the seat pneumatic relaxation suspension with two additional air volumes was created. Pneumatic motor – recuperator activated by means of air flow from the one additional volume to another is installed in air piping between additional volumes. Computational research was made in M...

  14. Optimal Alarm Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — An optimal alarm system is simply an optimal level-crossing predictor that can be designed to elicit the fewest false alarms for a fixed detection probability. It...

  15. Nuclear power plant alarm systems: Problems and issues

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, J.M.; Brown, W.S.

    1991-01-01

    Despite the incorporation of advanced technology into nuclear power plant alarm systems, human factors problems remain. This paper identifies to be addressed in order to allow advanced technology to be used effectively in the design of nuclear power plant alarm systems. The operator's use and processing of alarm system information will be considered. Based upon a review of alarm system research, issues related to general system design, alarm processing, display and control are discussed. It is concluded that the design of effective alarm systems depends on an understanding of the information processing capabilities and limitations of the operator. 39 refs.

  16. ALARM STRATEGY AND COMPLEXITY: PREDICTIONS OF OPERATOR RESPONSE

    Energy Technology Data Exchange (ETDEWEB)

    Austin Ragsdale; Roger Lew; Brian Dyre; Ronald Boring; David Gertman

    2012-07-01

    Decision support for operators is not new, and much has been written regarding the potential usefulness of digital support systems and alarm filtering strategies. However, determining the appropriate characteristics of decision support tools is difficult, especially when alarms can vary in the manner which diagnostic information is formulated and displayed and when event scenario types are complex and numerous. When first reviewed, the advantages or disadvantages of a particular alarm approach may not be apparent to the designer or analyst. The present research focuses on the review of two particular alarm strategies, binary alarm type (BAT) and likelihood alarm type (LAT), and reviews their influence upon accuracy, bias, and trust for tasks performed at a computer workstation capable of replicating a series of control-room-like alarms. The findings are discussed in terms of the of the performance advantages of likelihood alarm technology and related research as an aid to the alarm design process.

  17. Small-scale rotor test rig capabilities for testing vibration alleviation algorithms

    Science.gov (United States)

    Jacklin, Stephen A.; Leyland, Jane Anne

    1987-01-01

    A test was conducted to assess the capabilities of a small scale rotor test rig for implementing higher harmonic control and stability augmentation algorithms. The test rig uses three high speed actuators to excite the swashplate over a range of frequencies. The actuator position signals were monitored to measure the response amplitudes at several frequencies. The ratio of response amplitude to excitation amplitude was plotted as a function of frequency. In addition to actuator performance, acceleration from six accelerometers placed on the test rig was monitored to determine whether a linear relationship exists between the harmonics of N/Rev control input and the least square error (LSE) identification technique was used to identify local and global transfer matrices for two rotor speeds at two batch sizes each. It was determined that the multicyclic control computer system interfaced very well with the rotor system and kept track of the input accelerometer signals and their phase angles. However, the current high speed actuators were found to be incapable of providing sufficient control authority at the higher excitation frequencies.

  18. Smart smoke alarm

    Science.gov (United States)

    Warmack, Robert J. Bruce; Wolf, Dennis A; Frank, Steven Shane

    2015-04-28

    Methods and apparatus for smoke detection are disclosed. In one embodiment, a smoke detector uses linear discriminant analysis (LDA) to determine whether observed conditions indicate that an alarm is warranted.

  19. Security Alarm for Motorcycle

    Directory of Open Access Journals (Sweden)

    Ismail Ismail

    2015-11-01

    Full Text Available A security alarm for motorcycle has been developed. This equipment consists of two parts. Part one is as a remote control, where it produces a radio signal with frequency of 37.5 MHz to turn on (activate or to turn off alarm. Part two consists of sensor, receiver to receive signal from part one, and alarm. This part two will be attached to motorcycle while part one will be kept as a key by the owner of motorcycle. This equipment has been tested in the laboratory and it worked well. When part two is activated by pushing the “set button” in part one, then any movement of part two (as a movement of motor cycle by about 20 cm from initial position will cause the alarm sounds continuously. The alarm will be off whenever the “reset button” in part one is pushed. Part one (a remote control can activate part two with a maximum of twelve meter separation apart. This shows that the equipment can be used as a security alarm to prevent the motorcycle to be stolen in the future.

  20. Gynecological cancer alarm symptoms:

    DEFF Research Database (Denmark)

    Balasubramaniam, Kirubakaran; Ravn, Pernille; dePont Christensen, René

    2016-01-01

    AND METHODS: Nationwide population-based prospective cohort study in Denmark, based on a random sample of 51 090 women aged 20 years or older from the general population. A web-based questionnaire regarding gynecological alarm symptoms and lifestyle was distributed to the invited individuals. Data about...... and odds ratios (ORs) for associations between specialist care contact, lifestyle factors and socioeconomic status. RESULTS: The study included 25 866 non-pregnant women; 2957 reported the onset of at least one gynecological cancer alarm symptom, and 683 of these (23.1%) reported symptoms to their general...... practitioner. The proportion of individuals having contact with specialist care ranged from 39.3% (pain during intercourse) to 47.8% (bleeding during intercourse) Individuals with higher educational level had significantly higher odds of contact with a specialist (OR 1.86, CI; 1.17-2.95). CONCLUSIONS...

  1. Control of ELT false alarms

    Science.gov (United States)

    Toth, S.; Gershkoff, I.

    1979-01-01

    The statistics of emergency locator transmitter (ELT) alarms are presented. The primary sources of data include ELT Incident Logs, Service Difficulty Reports, and Frequency Interference Reports. The number of reported and unreported alarms is discussed, as are seasonal variations, duration of ELT transmissions, and cost of silencing. Origin, causes, and possible strategies for reducing the impact of alarms on the aviation community are considered.

  2. Investigation of Stability Alarming for Retaining Wall Structures with Damage

    Directory of Open Access Journals (Sweden)

    Qian Xu

    2017-01-01

    Full Text Available To warn of the stability of retaining wall structures with damage, a simplified mechanical model and a finite element model of this retaining wall-soil coupling system are established. Via finite element model updating, a baseline finite element model of the wall-soil system is acquired. A damage alarming index ERSD (Energy Ratio Standard Deviation is proposed via the wavelet packet analysis of a virtual impulse response function of dynamic responses to this baseline finite element model. The internal relationships among the alarming index, earth pressure, and damage stability of the wall are analyzed. Then, a damage stability alarming method for the retaining walls is advanced. To verify the feasibility and validity of this alarming method, vibration tests on the baseline finite element model of a pile plate retaining wall are performed. The ERSD is used as an alarm for the damage stability of the wall. Analysis results show that, with an increase in the ERSD, the stability of the wall changes from a stable state to an unstable one. The wall reaches a critical stable state when the alarming index reaches its threshold value. Thus, the damage stability of this pile plate retaining wall can be alarmed via ERSD.

  3. Alarm annunciation in a graphical environment

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.G.

    1994-08-01

    Well-designed graphical user interfaces, such as Microsoft Windows{trademark} or UNIX{trademark} -- based X-Windows, provide a capability for enhanced display of security alarm information. Conversely, a poorly designed interface can quickly overwhelm an operator. This paper describes types of graphical information that can be displayed and offers guidance on how to best display that information. Limits are proposed for the complexity of the user interface, and guidelines are suggested for the display of maps and sensors.

  4. Component mode synthesis and large deflection vibration of complex structures. Volume 1: Examples of NASTRAN modal synthesis capability

    Science.gov (United States)

    Mei, Chuh; Shen, Mo-How

    1987-01-01

    The use of NASTRAN model synthesis capability is illustrated. A classical truss problem is examined and the results are compared to results from other methods to test for accuracy. The problem is examined using both fixed interface modes and free interface modes. The solution is carried out for an applied dynamic load as far as recovery of forces in individual members as a function of time. Another small beam problem is used to compare different means of combining substructures.

  5. Fundamental Principles of Alarm Design

    DEFF Research Database (Denmark)

    Us, Tolga; Jensen, Niels; Lind, Morten

    2011-01-01

    be applied to any engineering system which can be modeled by MFM. The methodology provides a set of alarms which can facilitate event interpretation and operator support for abnormal situation management. The proposed design methodology provides the information content of the alarms, but does not deal...

  6. PT-SAFE: a software tool for development and annunciation of medical audible alarms.

    Science.gov (United States)

    Bennett, Christopher L; McNeer, Richard R

    2012-03-01

    Recent reports by The Joint Commission as well as the Anesthesia Patient Safety Foundation have indicated that medical audible alarm effectiveness needs to be improved. Several recent studies have explored various approaches to improving the audible alarms, motivating the authors to develop real-time software capable of comparing such alarms. We sought to devise software that would allow for the development of a variety of audible alarm designs that could also integrate into existing operating room equipment configurations. The software is meant to be used as a tool for alarm researchers to quickly evaluate novel alarm designs. A software tool was developed for the purpose of creating and annunciating audible alarms. The alarms consisted of annunciators that were mapped to vital sign data received from a patient monitor. An object-oriented approach to software design was used to create a tool that is flexible and modular at run-time, can annunciate wave-files from disk, and can be programmed with MATLAB by the user to create custom alarm algorithms. The software was tested in a simulated operating room to measure technical performance and to validate the time-to-annunciation against existing equipment alarms. The software tool showed efficacy in a simulated operating room environment by providing alarm annunciation in response to physiologic and ventilator signals generated by a human patient simulator, on average 6.2 seconds faster than existing equipment alarms. Performance analysis showed that the software was capable of supporting up to 15 audible alarms on a mid-grade laptop computer before audio dropouts occurred. These results suggest that this software tool provides a foundation for rapidly staging multiple audible alarm sets from the laboratory to a simulation environment for the purpose of evaluating novel alarm designs, thus producing valuable findings for medical audible alarm standardization.

  7. Identifying Causality from Alarm Observations

    DEFF Research Database (Denmark)

    Kirchhübel, Denis; Zhang, Xinxin; Lind, Morten

    on an abstracted model of the mass and energy flows in the system. The application of MFM for root cause analysis based alarm grouping has been demonstrated and can be extended to reason about the direction of causality considering the entirety of the alarms present in the system for more comprehensive decision...... and consequences. This extended analysis results in causal paths from likely root causes to tentative consequences, providing the operator with a comprehensive tool to not only identify but also rank the criticality of a large number of concurrent alarms in the system....... support. This contribution presents the foundation for combining the cause and consequence propagation of multiple observations from the system based on an MFM model. The proposed logical reasoning matches actually observed alarms to the propagation analysis in MFM to distinguish plausible causes...

  8. SCADA alarms processing for wind turbine component failure detection

    Science.gov (United States)

    Gonzalez, E.; Reder, M.; Melero, J. J.

    2016-09-01

    Wind turbine failure and downtime can often compromise the profitability of a wind farm due to their high impact on the operation and maintenance (O&M) costs. Early detection of failures can facilitate the changeover from corrective maintenance towards a predictive approach. This paper presents a cost-effective methodology to combine various alarm analysis techniques, using data from the Supervisory Control and Data Acquisition (SCADA) system, in order to detect component failures. The approach categorises the alarms according to a reviewed taxonomy, turning overwhelming data into valuable information to assess component status. Then, different alarms analysis techniques are applied for two purposes: the evaluation of the SCADA alarm system capability to detect failures, and the investigation of the relation between components faults being followed by failure occurrences in others. Various case studies are presented and discussed. The study highlights the relationship between faulty behaviour in different components and between failures and adverse environmental conditions.

  9. CERN Alarms Data Management: State And Improvements

    CERN Document Server

    Zaharieva, Z

    2011-01-01

    The CERN Alarms System - LASER is a centralized service ensuring the capturing, storing and notification of anomalies for the whole accelerator chain, including the technical infrastructure at CERN. The underlying database holds the pre-defined configuration data for the alarm definitions, for the Operators alarms consoles as well as the time-stamped, run-time alarm events, propagated through the Alarms Systems. The article will discuss the current state of the Alarms database and recent improvements that have been introduced. It will look into the data management challenges related to the alarms configuration data that is taken from numerous sources. Specially developed Extract-Transform-Load (ETL) processes must be applied to this data in order to transform it into an appropriate format and load it into the Alarms database. The recorded alarms events together with some additional data, necessary for providing events statistics to users, are transferred to the long-term alarms archive.The article will cover...

  10. Recent Results on "Approximations to Optimal Alarm Systems for Anomaly Detection"

    Science.gov (United States)

    Martin, Rodney Alexander

    2009-01-01

    An optimal alarm system and its approximations may use Kalman filtering for univariate linear dynamic systems driven by Gaussian noise to provide a layer of predictive capability. Predicted Kalman filter future process values and a fixed critical threshold can be used to construct a candidate level-crossing event over a predetermined prediction window. An optimal alarm system can be designed to elicit the fewest false alarms for a fixed detection probability in this particular scenario.

  11. Integrated alarm annunciation and entry control systems -- Survey results

    Energy Technology Data Exchange (ETDEWEB)

    Clever, J.J.; Arakaki, L.H.; Monaco, F.M.; Juarros, L.E.; Quintana, G.R.

    1993-10-01

    This report provides the results and analyses of a detailed survey undertaken in Summer 1993 to address integrated intrusion detection alarm annunciation and entry control system issues. This survey was undertaken as a first attempt toward beginning to answer questions about integrated systems and commercial capabilities to meet or partially meet US Department of Energy (DOE) site needs.

  12. 21 CFR 876.2040 - Enuresis alarm.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Enuresis alarm. 876.2040 Section 876.2040 Food and... GASTROENTEROLOGY-UROLOGY DEVICES Monitoring Devices § 876.2040 Enuresis alarm. (a) Identification. An enuresis... type of device includes conditioned response enuresis alarms. (b) Classification. Class II (special...

  13. 24 CFR 3285.703 - Smoke alarms.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the smoke...

  14. HYBRID ALARM SYSTEMS: COMBINING SPATIAL ALARMS AND ALARM LISTS FOR OPTIMIZED CONTROL ROOM OPERATION

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; J.J. Persensky

    2012-07-01

    The US Department of Energy (DOE) is sponsoring research, development, and deployment on Light Water Reactor Sustainability (LWRS), in which the Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe operational life extension of current nuclear power plants. One of the main areas of focus is control room modernization. Within control room modernization, alarm system upgrades present opportunities to meet the broader goals of the LWRS project in demonstrating the use and safety of the advanced instrumentation and control (I&C) technologies and the short-term and longer term objectives of the plant. In this paper, we review approaches for and human factors issues behind upgrading alarms in the main control room of nuclear power plants.

  15. HOME INSECURITY: NO ALARMS, FALSE ALARMS, AND SIGINT

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, Logan M [ORNL

    2014-01-01

    The market share of home security systems has substantially increased as vendors incorporate more desirable features: intrusion detection, automation, wireless, and LCD touch panel controls. Wireless connectivity allows vendors to manufacture cheaper, more featureful products that require little to no home modification to install. Consumer win, since adding devices is easier. The result: an ostensibly more secure, convenient, and connected home for a larger number of citizens. Sadly, this hypothesis is flawed; the idea of covering a home with more security sensors does not translate into a more secure home. Additionally, the number of homes using these vulnerable systems is large, and the growth rate is increasing producing a even larger problem. In this talk, I will demonstrate a generalized approach for compromising three systems: ADT, the largest home security dealer in North America; Honeywell, one of the largest manufacturers of security devices; and Vivint, a top 5 security dealer. We will suppress alarms, create false alarms, and collect artifacts that facilitate tracking the movements of individuals in their homes.

  16. Video systems for alarm assessment

    Energy Technology Data Exchange (ETDEWEB)

    Greenwoll, D.A.; Matter, J.C. (Sandia National Labs., Albuquerque, NM (United States)); Ebel, P.E. (BE, Inc., Barnwell, SC (United States))

    1991-09-01

    The purpose of this NUREG is to present technical information that should be useful to NRC licensees in designing closed-circuit television systems for video alarm assessment. There is a section on each of the major components in a video system: camera, lens, lighting, transmission, synchronization, switcher, monitor, and recorder. Each section includes information on component selection, procurement, installation, test, and maintenance. Considerations for system integration of the components are contained in each section. System emphasis is focused on perimeter intrusion detection and assessment systems. A glossary of video terms is included. 13 figs., 9 tabs.

  17. Expert systems and microwave communication systems alarms processing: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tonn, B.; Goeltz, R.; Purucker, S.

    1987-07-01

    This report presents the results of a feasibility study conducted by Oak Ridge National Laboratory (ORNL) for the Bonneville Power Administration concerning the applicability of Artificial Intelligence (AI) technology to process alarms associated with Bonneville's Microwave Communication System (MCS). Specifically, the discussion focuses on the characteristics of a prototype expert system/database management system (DBMS) configuration capable of intelligently processing alarms, efficiently storing alarm-based historical data, and providing analysis and reporting tools. Such a system has the potential to improve response to critical alarms, increase the information content of a large volume of complicated data, free operators from performing routine analysis, and provide alarm information to operators, field personnel, and management through queries and automatically produced reports.

  18. Alarm management for storage and transportation terminals; Gerenciamento de alarmes para terminais de transferencia e estocagem

    Energy Technology Data Exchange (ETDEWEB)

    Loureiro, Patricia [PETROBRAS, Rio de Janeiro, RJ (Brazil); Feldman, Rafael Noac [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2005-07-01

    Recently, in many industrial segments, it has been taken into account the issues related to the high amount of alarms that are announced in the control rooms, even if the industrial process is under normal conditions. Recent studies and surveys have shown that the three major problems related to it are: alarms that remain active during normal operation; alarms that remain chattering during an operational period; the phenomenon called Alarm flood, that occurs when an extensive amount of alarms is announced and the operator does not have enough time to take effective actions. In order to reduce or to eliminate the two above mentioned causes, alarm analysis and housekeeping, called Alarm Rationalization, have been efficient in major cases, because such facts occur mainly due to inadequate limits definition and/or equipment and instruments out of service or in maintenance. Such alarms are called in the literature as bad-actors or villains, and their occurrences may reach up to 50% of the daily total amount of alarms. This paper aims to present the main results of a project named Alarm Management for Transfer and Storage Terminals. The project development is based on two different terminal surveys, in order not only to identify the most frequent causes of undesirable alarms, but also to generate design standards. The main phases of the project are: alarm rationalization based on bad-actors detection; generate a set of design and operation standards; generate an Alarm Philosophy document for the Terminals. (author)

  19. Identification and Isolation of Human Alarm Pheromones

    National Research Council Canada - National Science Library

    Mujica-Parodi, Lilianne R; Strey, Helmut

    2006-01-01

    .... Task I, Optimization of Sample Collection, focused on the collection of the putative alarm pheromone via axillary sweat samples obtained during reference (physical exercise) and arousal (skydive) conditions...

  20. Cost effectiveness of residential carbon monoxide alarms.

    Science.gov (United States)

    Hampson, Neil B

    2017-01-01

    While residential carbon monoxide (CO) alarms are now required in a majority of states, the cost effectiveness of the devices is unknown. This analysis was performed to determine the degree of prevention efficacy necessary from home carbon monoxide alarms for their expense to be cost-effective. Data regarding numbers of individuals affected in the United States annually from accidental, non-fire, residential non-fatal and fatal carbon monoxide poisoning were obtained from published literature. Federal governmental estimates of societal costs associated with medical care, lost wages and earnings, value of pain and suffering, and value of a statistical life were applied. The cost of uniform residential carbon monoxide alarm installation was compared to those societal costs in order to calculate what degree of efficiency makes alarms cost-effective. Societal costs for accidental, non-fire, residential CO poisoning are approximately $3.47 billion annually. With an estimated cost of $348 million annually for alarms, prevention of greater than 10% of residential CO poisoning costs must be achieved in order for alarms to be cost-effective. While the true effectiveness of residential carbon monoxide alarms has yet to be determined, current state legislation requiring residential installation of CO alarms is probably cost-effective. .

  1. Useful and usable alarm systems : recommended properties

    Energy Technology Data Exchange (ETDEWEB)

    Veland, Oeystein; Kaarstad, Magnhild; Seim, Lars Aage; Foerdestroemmen, Nils T.

    2001-01-15

    This document describes the result of a study on alarm systems conducted by IFE in Halden. The study was initiated by the Norwegian Petroleum Directorate. The objective was to identify and formulate a set of important properties for useful and usable alarm systems. The study is mainly based on review of the latest international recognised guidelines and standards on alarm systems available at the time of writing, with focus on realistic solutions from research and best practice from different industries. In addition, IFE experiences gathered through specification and design of alarm systems and experimental activities in HAMMLAB and bilateral projects, have been utilized where relevant. The document presents a total of 43 recommendations divided into a number of general recommendations and more detailed recommendations on alarm generation, structuring, prioritisation, presentation and handling. (Author)

  2. Recommendations for the LHC safety alarm system

    CERN Document Server

    Laeger, H

    1999-01-01

    A working group was set up to define the LHC safety alarm system, also known as Alarm-of-Level-3-System (AL3S). The mandate asked for recommendations to be elaborated on four items: the overall concept of the AL3S for machine and experiments, the transmission and display of safety alarms, the AL3S during civil engineering construction, and the transition from the present LEP to the final LHC safety alarm system. The members of the working group represented a wide range of interest and experience including the CERN Fire Brigade, safety officers from experiments and machines, and specialists for safety and control systems. The recommendations highlight the need for a clear definition of responsibilities and procedures, well-engineered homogeneous systems across CERN, and they point to several important issues outside the mandate of the working group. These recommendations were presented, discussed and accepted by several CERN and LHC committees.

  3. The alarming increase of incapacity for work

    National Research Council Canada - National Science Library

    Thibaut, P

    2013-01-01

    The alarming increase of incapacity for work The increase of incapacity for work in Belgium and in Europe is not a new phenomenon but only the transposition of an experience already lived on others continents (Canada--USA...

  4. 46 CFR 169.732 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...

  5. 46 CFR 78.47-9 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping... and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” (b) ...

  6. 46 CFR 97.37-9 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...

  7. 46 CFR 108.627 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED” next to...

  8. 46 CFR 196.37-9 - Carbon dioxide alarm.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...

  9. System for alarms analysis and optimization in petrochemicals plants; Sistema para analise e otimizacao de alarmes em plantas petroquimicas

    Energy Technology Data Exchange (ETDEWEB)

    Leitao, Gustavo; Pifer, Aderson; Guedes, Luiz Affonso [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Saito, Kaku; Aquino, Leonardo [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2008-07-01

    The present work presents a group of algorithms, techniques and functionalities on alarms management which can be used efficiently on the treatment of 'disturbances' caused by the informal management of the alarm systems. Among the disturbances handled by these techniques, there is the recognition of intermittent alarms and false alarms, location of alarm floods and correlation between alarms, aiming the identification of communal root causes. The results will be presented through a case study on petrochemical alarm plants. At last, the results obtained by the utilization of such functionalities will be presented and discussed. (author)

  10. Do Scaphoideus titanus (Hemiptera: Cicadellidae) nymphs use vibrational communication?

    Science.gov (United States)

    Chuche, Julien; Thiéry, Denis; Mazzoni, Valerio

    2011-07-01

    Small Auchenorrhyncha use substrate-borne vibrations to communicate. Although this behaviour is well known in adult leafhoppers, so far no studies have been published on nymphs. Here we checked the occurrence of vibrational communication in Scaphoideus titanus (Hemiptera: Cicadellidae) nymphs as a possible explanation of their aggregative distributions on host plants. We studied possible vibratory emissions of isolated and grouped nymphs, as well as their behavioural responses to vibration stimuli that simulated presence of conspecifics, to disturbance noise, white noise and predator spiders. None of our synthetic stimuli or pre-recorded substrate vibrations from nymphs elicited specific vibration responses and only those due to grooming or mechanical contacts of the insect with the leaf were recorded. Thus, S. titanus nymphs showed to not use species-specific vibrations neither for intra- nor interspecific communication and also did not produce alarm vibrations when facing potential predators. We conclude that their aggregative behaviour is independent from a vibrational communication.

  11. 49 CFR 178.608 - Vibration standard.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Vibration standard. 178.608 Section 178.608... Testing of Non-bulk Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section...

  12. 49 CFR 178.985 - Vibration test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Vibration test. 178.985 Section 178.985... Testing of Large Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A...

  13. Capability Paternalism

    NARCIS (Netherlands)

    Claassen, R.J.G.|info:eu-repo/dai/nl/269266224

    A capability approach prescribes paternalist government actions to the extent that it requires the promotion of specific functionings, instead of the corresponding capabilities. Capability theorists have argued that their theories do not have much of these paternalist implications, since promoting

  14. Stand-alone tsunami alarm equipment

    Science.gov (United States)

    Katsumata, Akio; Hayashi, Yutaka; Miyaoka, Kazuki; Tsushima, Hiroaki; Baba, Toshitaka; Catalán, Patricio A.; Zelaya, Cecilia; Riquelme Vasquez, Felipe; Sanchez-Olavarria, Rodrigo; Barrientos, Sergio

    2017-05-01

    One of the quickest means of tsunami evacuation is transfer to higher ground soon after strong and long ground shaking. Ground shaking itself is a good initiator of the evacuation from disastrous tsunami. Longer period seismic waves are considered to be more correlated with the earthquake magnitude. We investigated the possible application of this to tsunami hazard alarm using single-site ground motion observation. Information from the mass media is sometimes unavailable due to power failure soon after a large earthquake. Even when an official alarm is available, multiple information sources of tsunami alert would help people become aware of the coming risk of a tsunami. Thus, a device that indicates risk of a tsunami without requiring other data would be helpful to those who should evacuate. Since the sensitivity of a low-cost MEMS (microelectromechanical systems) accelerometer is sufficient for this purpose, tsunami alarm equipment for home use may be easily realized. Amplitude of long-period (20 s cutoff) displacement was proposed as the threshold for the alarm based on empirical relationships among magnitude, tsunami height, hypocentral distance, and peak ground displacement of seismic waves. Application of this method to recent major earthquakes indicated that such equipment could effectively alert people to the possibility of tsunami.

  15. 46 CFR 63.15-7 - Alarms.

    Science.gov (United States)

    2010-10-01

    ... reset. (c) For steam boilers, operation of the lower low water cutoff must automatically sound an..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General... periodically unattended machinery space, the auxiliary boiler trip alarm required by 46 CFR 62.35-50, Table 62...

  16. Mianserin affects alarm reaction to conspecific chemical alarm cues in Nile tilapia.

    Science.gov (United States)

    Barreto, Rodrigo Egydio

    2017-02-01

    In this study, I show that mianserin, a chemical with serotonin and adrenoceptor antagonist activities, increases fish vulnerability to a potential predator threat, when prey fish must deal with this threat based on conspecific chemical alarm cues. For that, I evaluated whether mianserin, diluted in the water, influences the behavioral responses of Nile tilapia (Oreochromis niloticus) to conspecific skin extract (chemical alarm cues). I found that, while mianserin did not abolished antipredator responses, this drug mitigates some components of this defensive reaction. Thus, a potential decrease in serotonin and adrenergic activities reduces the ability of dealing with predators when perceiving conspecific chemical alarm cues.

  17. Do nuisance alarms decrease functionality of smoke alarms near the kitchen? Findings from a randomised controlled trial.

    Science.gov (United States)

    Yang, Jingzhen; Jones, Michael P; Cheng, Gang; Ramirez, Marizen; Taylor, Craig; Peek-Asa, Corinne

    2011-06-01

    Many home fires begin in the kitchen. Kitchen smoke alarms are more likely to produce nuisance alarms, but few previous studies have examined the role of alarm sensor and battery types on the functionality of smoke alarms located nearest to the kitchen. Data were analysed from a 2×2 factorial randomised controlled trial conducted in rural Iowa homes (n=628). Enrolled households were randomly assigned into one of four smoke alarm/battery combinations: ionisation/zinc, ionisation/lithium, photoelectric/zinc and photoelectric/lithium. Alarm functionality was determined using a smoke test. Alarm type and battery type were compared using an intent-to-treat analysis. Logistic regression was used to identify factors that might impact the functionality of smoke alarms located nearest to the kitchen 42 months after installation. Photoelectric alarms with lithium batteries had the highest rate of functionality (90.2%), whereas ionisation alarms with carbon/zinc batteries had the lowest (76.5%). Forty-two months following installation, 6.4% more of photoelectric alarms were functional than ionisation alarms, and 7.9% more of alarms with lithium batteries were functional than those with carbon/zinc batteries. Logistic regression revealed that when the indicator of nuisance alarms was included, the effect of alarm type became statistically insignificant and ionisation alarms were less likely to be functional at 42 months, partly due to increased nuisance alarms. Alarm type is an important consideration for certain locations. Photoelectric alarms may be more appropriate for installation nearest to the kitchen despite their increased cost. These findings can help guide consumer choices to increase protection against home fire-related injuries and deaths.

  18. Attitude of resident doctors towards intensive care units′ alarm settings

    Directory of Open Access Journals (Sweden)

    Rakesh Garg

    2010-01-01

    Full Text Available Intensive care unit (ICU monitors have alarm options to intimate the staff of critical incidents but these alarms needs to be adjusted in every patient. With this objective in mind, this study was done among resident doctors, with the aim of assessing the existing attitude among resident doctors towards ICU alarm settings. This study was conducted among residents working at ICU of a multispeciality centre, with the help of a printed questionnaire. The study involved 80 residents. All residents were in full agreement on routine use of ECG, pulse oximeter, capnograph and NIBP monitoring. 86% residents realised the necessity of monitoring oxygen concentration, apnoea monitoring and expired minute ventilation monitoring. 87% PGs and 70% SRs routinely checked alarm limits for various parameters. 50% PGs and 46.6% SRs set these alarm limits. The initial response to an alarm among all the residents was to disable the alarm temporarily and try to look for a cause. 92% of PGs and 98% of SRs were aware of alarms priority and colour coding. 55% residents believed that the alarm occurred due to patient disturbance, 15% believed that alarm was due to technical problem with monitor/sensor and 30% thought it was truly related to patient′s clinical status. 82% residents set the alarms by themselves, 10% believed that alarms should be adjusted by nurse, 4% believed the technical staff should take responsibility of setting alarm limits and 4% believed that alarm levels should be pre-adjusted by the manufacturer. We conclude that although alarms are an important, indispensable, and lifesaving feature, they can be a nuisance and can compromise quality and safety of care by frequent false positive alarms. We should be familiar of the alarm modes, check and reset the alarm settings at regular interval or after a change in clinical status of the patient.

  19. LBTO Alarm Notification/Management and Error Diagnostic Tools

    Science.gov (United States)

    De La Peña, M. D.; Biddick, C.; Summers, K.; Summers, D.

    2015-09-01

    The Large Binocular Telescope Observatory (LBTO) Telescope Control System (TCS) is comprised of fifteen subsystems and accepts commands from the operator, as well as from six pairs of instruments. To the operator the TCS presents as a high-level set of GUIs with each GUI corresponding to one specific subsystem and providing full state information and varying degrees of control. The TCS GUIs not only provide the operators with broad control over all aspects of the telescope, but each individual GUI also reports problems within its domain through the use of color-coded messages and widgets indicating the seriousness of the issue. While there is significant problem reporting available to the operator, until recently there was no centralized and persistent visual indication or “annunciator” display for issues. In order to provide a way to present problems in a centralized and persistent fashion with “on-the-spot guidance” to ease the job of the operator and to have an acknowledge capability, the LBTO project decided to leverage an existing Alarm Handler which is a GUI client application associated with the Experimental Physics and Industrial Control System (EPICS)1. This paper briefly describes the TCS sources of problem reporting information and how the EPICS Alarm Handler supplements the current system.

  20. Interspecific semantic alarm call recognition in the solitary Sahamalaza sportive lemur, Lepilemur sahamalazensis.

    Directory of Open Access Journals (Sweden)

    Melanie Seiler

    Full Text Available As alarm calls indicate the presence of predators, the correct interpretation of alarm calls, including those of other species, is essential for predator avoidance. Conversely, communication calls of other species might indicate the perceived absence of a predator and hence allow a reduction in vigilance. This "eavesdropping" was demonstrated in birds and mammals, including lemur species. Interspecific communication between taxonomic groups has so far been reported in some reptiles and mammals, including three primate species. So far, neither semantic nor interspecific communication has been tested in a solitary and nocturnal lemur species. The aim of this study was to investigate if the nocturnal and solitary Sahamalaza sportive lemur, Lepilemur sahamalazensis, is able to access semantic information of sympatric species. During the day, this species faces the risk of falling prey to aerial and terrestrial predators and therefore shows high levels of vigilance. We presented alarm calls of the crested coua, the Madagascar magpie-robin and aerial, terrestrial and agitation alarm calls of the blue-eyed black lemur to 19 individual Sahamalaza sportive lemurs resting in tree holes. Songs of both bird species' and contact calls of the blue-eyed black lemur were used as a control. After alarm calls of crested coua, Madagascar magpie-robin and aerial alarm of the blue-eyed black lemur, the lemurs scanned up and their vigilance increased significantly. After presentation of terrestrial alarm and agitation calls of the blue-eyed black lemur, the animals did not show significant changes in scanning direction or in the duration of vigilance. Sportive lemur vigilance decreased after playbacks of songs of the bird species and contact calls of blue-eyed black lemurs. Our results indicate that the Sahamalaza sportive lemur is capable of using information on predator presence as well as predator type of different sympatric species, using their referential

  1. Design for Vibration Monitoring: A Methodology for Reliable and Cost-Effective Vibration Monitoring

    Science.gov (United States)

    Tumer, Irem Y.; Koga, Dennis (Technical Monitor)

    2001-01-01

    The purpose of health monitoring systems is to detect failures or defects for increased safety and performance and to provide on-condition maintenance with reduced costs. The problems associated with health monitoring systems include high rates of false alarms and missed failures, which make monitoring an unreliable and costly task. The reason for this is that unaccounted variations invalidate signal modeling assumptions. Our approach was to focus on vibration monitoring of rotating components. We analyzed baseline signals to determine statistical variations, identify and model factors that influence vibrations (pre-production vs. post-production variations), determine hit and false alarm rates with baseline flight data, model and predict effects of defects and variations on vibrations, and develop algorithms and metrics for failure and anomaly detection in the presence of variations.

  2. Criticality accident alarm system at the Fernald Environmental Management Project

    Energy Technology Data Exchange (ETDEWEB)

    Marble, R.C.; Brown, T.D.; Wooldridge, J.C.

    1994-12-31

    This paper describes the staus of the Fernald Environmental Management Project (FEMP) criticality alarm system. A new radiation detection alarm system was installed in 1990. The anunciation system, calibration and maintenance, and detector placement is described.

  3. Technological Distractions (Part 2): A Summary of Approaches to Manage Clinical Alarms With Intent to Reduce Alarm Fatigue.

    Science.gov (United States)

    Winters, Bradford D; Cvach, Maria M; Bonafide, Christopher P; Hu, Xiao; Konkani, Avinash; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; Pelter, Michele M; McLean, Barbara; Kane-Gill, Sandra L

    2018-01-01

    Alarm fatigue is a widely recognized safety and quality problem where exposure to high rates of clinical alarms results in desensitization leading to dismissal of or slowed response to alarms. Nonactionable alarms are thought to be especially problematic. Despite these concerns, the number of clinical alarm signals has been increasing as an everincreasing number of medical technologies are added to the clinical care environment. PubMed, SCOPUS, Embase, and CINAHL. We performed a systematic review of the literature focused on clinical alarms. We asked a primary key question; "what interventions have been attempted and resulted in the success of reducing alarm fatigue?" and 3-secondary key questions; "what are the negative effects on patients/families; what are the balancing outcomes (unintended consequences of interventions); and what human factor approaches apply to making an effective alarm?" Articles relevant to the Key Questions were selected through an iterative review process and relevant data was extracted using a standardized tool. We found 62 articles that had relevant and usable data for at least one key question. We found that no study used/developed a clear definition of "alarm fatigue." For our primary key question 1, the relevant studies focused on three main areas: quality improvement/bundled activities; intervention comparisons; and analysis of algorithm-based false and total alarm suppression. All sought to reduce the number of total alarms and/or false alarms to improve the positive predictive value. Most studies were successful to varying degrees. None measured alarm fatigue directly. There is no agreed upon valid metric(s) for alarm fatigue, and the current methods are mostly indirect. Assuming that reducing the number of alarms and/or improving positive predictive value can reduce alarm fatigue, there are promising avenues to address patient safety and quality problem. Further investment is warranted not only in interventions that may reduce

  4. Panic, Suffocation False Alarms, Separation Anxiety and Endogenous Opioids

    OpenAIRE

    Preter, Maurice; Klein, Donald F.

    2007-01-01

    This review paper presents an amplification of the suffocation false alarm theory (SFA) of spontaneous panic (Klein, 1993). SFA postulates the existence of an evolved physiologic suffocation alarm system that monitors information about potential suffocation. Panic attacks maladaptively occur when the alarm is erroneously triggered. That panic is distinct from Cannon’s emergency fear response and Selye’s General Alarm Syndrome is shown by the prominence of intense air hunger during these attac...

  5. Car Alarm System Engineered In Arduino Environment

    OpenAIRE

    Järvelä, Sakari

    2014-01-01

    This thesis is targeting to develop and engineer a burglar alarm system prototype using the software and hardware environment Arduino, which is originally manufactured by Smart Projects. The system under development provides a versatile theft inhibition hardware configuration for the holder of the system. It also provides vehicle localization enabling features in case of theft. In the final project, the aim is not to reach commercial benefit. The aim is to get familiar with software libra...

  6. The response of theatre personnel to the pulse oximeter alarm ...

    African Journals Online (AJOL)

    Background: False alarms and sounds in the operating theatre (OT) that alert personnel to a crisis can be irritating. This can result in personnel ignoring genuine alarm warnings. This study was carried out to determine how alert OT personnel are in response to the pulse oximeter alarm. Method: For the purposes of the ...

  7. 46 CFR 169.730 - General alarm bell switch.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse, clearly...

  8. 46 CFR 108.623 - General alarm bell switch.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing. ...

  9. 21 CFR 870.1100 - Blood pressure alarm.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  10. Poison and alarm: the Asian hornet Vespa velutina uses sting venom volatiles as an alarm pheromone.

    Science.gov (United States)

    Cheng, Ya-Nan; Wen, Ping; Dong, Shi-Hao; Tan, Ken; Nieh, James C

    2017-02-15

    In colonial organisms, alarm pheromones can provide a key fitness advantage by enhancing colony defence and warning of danger. Learning which species use alarm pheromone and the key compounds involved therefore enhances our understanding of how this important signal has evolved. However, our knowledge of alarm pheromones is more limited in the social wasps and hornets compared with the social bees and ants. Vespa velutina is an economically important and widespread hornet predator that attacks honey bees and humans. This species is native to Asia and has now invaded Europe. Despite growing interest in V. velutina, it was unknown whether it possessed an alarm pheromone. We show that these hornets use sting venom as an alarm pheromone. Sting venom volatiles were strongly attractive to hornet workers and triggered attacks. Two major venom fractions, consisting of monoketones and diketones, also elicited attack. We used gas chromatography coupled to electroantennographic detection (GC-EAD) to isolate 13 known and 3 unknown aliphatic ketones and alcohols in venom that elicited conspicuous hornet antennal activity. Two of the unknown compounds may be an undecen-2-one and an undecene-2,10-dinone. Three major compounds (heptan-2-one, nonan-2-one and undecan-2-one) triggered attacks, but only nonan-2-one did so at biologically relevant levels (10 hornet equivalents). Nonan-2-one thus deserves particular attention. However, the key alarm releasers for V. velutina remain to be identified. Such identification will help to illuminate the evolution and function of alarm compounds in hornets. © 2017. Published by The Company of Biologists Ltd.

  11. Recommendations to alarm systems and lessons learned on alarm system implementation

    Energy Technology Data Exchange (ETDEWEB)

    Soerenssen, Aimar; Veland, Oeystein; Farbrot, Jan Erik; Kaarstad, Magnhild; Seim, Lars Aage; Foerdestroemmen, Nils; Bye, Andreas

    2001-11-15

    Alarm systems have been of major concern within complex industrial processes for many years. Within the nuclear community, the TMI accident in 1979 was the first really serious event that showed also the importance of the man-machine aspects of the systems in general, and the alarm system in particular. The OECD Halden Reactor Project has been working with alarm systems since 1974. This report is an attempt to gather some of the knowledge that has been accumulated during the years in Halden, both in research and also in bilateral projects. Bilateral projects within this field have provided a practical basis of knowledge.A major part of this report consists of a set of recommendations, which reflect HRP's current understanding of how an alarm system should work. There are also recommendations on design methods. But also other issues are included, as system development and implementation experience, and experimental knowledge on the performance of alarm systems. Some open issues are also discussed. (Author). 54 refs., 15 figs

  12. Clinical Alarms in intensive care: implications of alarm fatigue for the safety of patients

    Directory of Open Access Journals (Sweden)

    Adriana Carla Bridi

    2014-12-01

    Full Text Available OBJECTIVES: to identify the number of electro-medical pieces of equipment in a coronary care unit, characterize their types, and analyze implications for the safety of patients from the perspective of alarm fatigue.METHOD: this quantitative, observational, descriptive, non-participatory study was conducted in a coronary care unit of a cardiology hospital with 170 beds.RESULTS: a total of 426 alarms were recorded in 40 hours of observation: 227 were triggered by multi-parametric monitors and 199 were triggered by other equipment (infusion pumps, dialysis pumps, mechanical ventilators, and intra-aortic balloons; that is an average of 10.6 alarms per hour.CONCLUSION: the results reinforce the importance of properly configuring physiological variables, the volume and parameters of alarms of multi-parametric monitors within the routine of intensive care units. The alarms of equipment intended to protect patients have increased noise within the unit, the level of distraction and interruptions in the workflow, leading to a false sense of security.

  13. Clinical alarm hazards: a "top ten" health technology safety concern.

    Science.gov (United States)

    Keller, James P

    2012-01-01

    For the past several years ECRI Institute has published a list of Top Ten Health Technology Hazards. This list is based on ECRI's extensive research in health technology safety and on data provided to its problemreporting systems. For every year that the Top Ten list has been published, Alarm Hazards have been at or near the top of the list. Improving alarm safety requires a systematic review of a hospital's alarm-based technologies and analysis of alarm management policies like alarm escalation strategies and staffing patterns. It also requires careful selection of alarm setting criteria for each clinical care area. This article will overview the clinical alarm problems that have been identified through ECRI Institute's research and analysis of various problem reporting databases, including those operated by ECRI Institute. It will also highlight suggestions for improvement, particularly from a technology design and technology management perspective. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Blade Vibration Measurement System

    Science.gov (United States)

    Platt, Michael J.

    2014-01-01

    The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.

  15. Kidkit guides children into alarming atmospheres

    DEFF Research Database (Denmark)

    Højlund, Marie; Kinch, Sofie

    2013-01-01

    on the development and evaluation of Kidkit, which is interactive furniture designed for young children who are going to visit a hospitalized relative with fatal injuries for the first time. Kidkit empowers the child to engage and be present by shaping Middle Ground Experiences in the hospital ward environment...... that is full of intimidating medical equipment and alarms. The evaluation results indicate collective rewards gained when children succeed in Embodied Habituation. Finally, the paper discusses how Middle Ground Experiences inevitably establish grounds for how we design for spatial experiences within...

  16. Alleviation of Buffet-Induced Vibration Using Piezoelectric Actuators

    National Research Council Canada - National Science Library

    Morgenstern, Shawn D

    2006-01-01

    .... The objective of this research was to determine the most critical natural modes of vibration for the F-16 ventral fin and design piezoelectric actuators capable of reducing buffet-induced ventral fin vibration...

  17. Monitoring vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Tiryaki, B. [Hacettepe University (Turkey). Dept. of Mining Engineering

    2003-12-01

    The paper examines the prediction and optimisation of machine vibrations in longwall shearers. Underground studies were carried out at the Middle Anatolian Lignite Mine, between 1993 and 1997. Several shearer drums with different pick lacing arrangements were designed and tested on double-ended ranging longwall shearers employed at the mine. A computer program called the Vibration Analysis Program (VAP) was developed for analysing machine vibrations in longwall shearers. Shearer drums that were tested underground, as well as some provided by leading manufacturers, were analyzed using these programs. The results of the experiments and computer analyses are given in the article. 4 refs., 9 figs.

  18. Capability ethics

    NARCIS (Netherlands)

    I.A.M. Robeyns (Ingrid)

    2012-01-01

    textabstractThe capability approach is one of the most recent additions to the landscape of normative theories in ethics and political philosophy. Yet in its present stage of development, the capability approach is not a full-blown normative theory, in contrast to utilitarianism, deontological

  19. A Design of Alarm System in a Research Reactor Facility

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jaekwan; Jang, Gwisook; Seo, Sangmun; Suh, Yongsuk [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The digital alarm system has become an indispensable design to process a large amount of alarms of power plants. Korean research reactor operated for decades maintains a hybrid alarm system with both an analog annunciator and a digital alarm display. In this design, several alarms are indicated on an analog panel and digital display, respectively, and it requires more attention and effort of the operators. As proven in power plants, a centralized alarm system design is necessary for a new research reactor. However, the number of alarms and operators in a research reactor is significantly lesser than power plants. Thus, simplification should be considered as an important factor for the operation efficiency. This paper introduces a simplified alarm system. As advances in information technology, fully digitalized alarm systems have been applied to power plants. In a new research reactor, it will be more useful than an analog or hybrid configuration installed in research reactors decades ago. However, the simplification feature should be considered as an important factor because the number of alarms and number of operators in a research reactor is significantly lesser than in power plants.

  20. Alarm management in gas pipeline plant: a case study

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Juliano; Lima, Marcelo; Leitao, Gustavo; Guedes, Luiz Affonso [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Branco, Nicolau; Coelho, Robson; Elias, Gustavo Passos; Nunes, Marcelo [Transportadora Brasileira Gasoduto Bolivia-Brasil (TBG), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    In order to improve the requirements of industrial processes, many decision support systems have been introduced in recent years. In this context, the alarm management systems have great relevance. On the other hand, the informatics revolution allowed a great increase of information concerning the operation of the industrial processes. Currently, process operators handle an excessive number of about 1.500 alarms per day. Thus, this overdose of information implies in the discredit of alarms. Then, in order to improve the operation activities of industrial processes, it is mandatory to incorporate procedures to evaluate and rationalize alarms. Since the EMMUA191 Standard is the reference guide to alarm management, but it does not specify how to execute an alarm management procedure, in this paper, a systematic procedure to evaluate alarms configurations in industrial processes is proposed. This procedure is in line with EMMUA191 and is composed by the following steps: to use statistics analyses to identify problematic alarms, such as occurrence, intermittency, correlation, and flooding calculation; to indicate problematic alarm group; and to propose a set of actions to be implemented. To validate our proposal, we present a case study in a gas pipeline plant using the BR-AlarmExpert software. (author)

  1. Development of net cage acoustic alarm system

    Science.gov (United States)

    Hong, Shih-Wei; Wei, Ruey-Chang

    2004-05-01

    In recent years, the fishery production has been drastically decreased in Taiwan, mainly due to overfishing and coast pollution; therefore, fishermen and corporations are encouraged by government to invest in ocean net cage aquaculture. However, the high-price fishes in the net cage are often coveted, so incidences of fish stealing and net cage breaking were found occasionally, which cause great economical loss. Security guards or a visual monitoring system has limited effect, especially in the night when these intrusions occur. This study is based on acoustic measure to build a net cage alarm system, which includes the sonobuoy and monitor station on land. The sonobuoy is a passive sonar that collects the sounds near the net cage and transmits the suspected signal to the monitor station. The signals are analyzed by the control program on the personal computer in the monitor station, and the alarms at different stages could be activated by the sound levels and durations of the analyzed data. To insure long hours of surveillance, a solar panel is applied to charge the battery, and a photodetector is used to activate the system.

  2. Vibrational Diver

    Science.gov (United States)

    Kozlov, Victor; Ivanova, Alevtina; Schipitsyn, Vitalii; Stambouli, Moncef

    2014-10-01

    The paper is concerned with dynamics of light solid in cavity with liquid subjected to rotational vibration in the external force field. New vibrational phenomenon - diving of a light cylinder to the cavity bottom is found. The experimental investigation of a horizontal annulus with a partition has shown that under vibration a light body situated in the upper part of the layer is displaced in a threshold manner some distance away from the boundary. In this case the body executes symmetric tangential oscillations. An increase of the vibration intensity leads to a tangential displacement of the body near the external boundary. This displacement is caused by the tangential component of the vibrational lift force, which appears as soon as the oscillations lose symmetry. In this case the trajectory of the body oscillatory motion has the form of a loop. The tangential lift force makes stable the position of the body on the inclined section of the layer and even in its lower part. A theoretical interpretation has been proposed, which explains stabilization of a quasi-equilibrium state of a light body near the cavity bottom in the framework of vibrational hydromechanics.

  3. General methods for alarm reduction; Larmsanering med generella metoder

    Energy Technology Data Exchange (ETDEWEB)

    Ahnlund, Jonas; Bergquist, Tord; Raaberg, Martin [Lund Univ. (Sweden). Dept. of Information Technology

    2003-10-01

    The information in the control rooms has increased due to the technological advances in process control. Large industries produce large data quantities, where some information is unnecessary or even incorrect. The operator needs support from an advanced and well-adjusted alarm system to be able to separate a real event from a minor disturbance. The alarms must be of assistance and not a nuisance. An enhanced alarm situation qualifies an increased efficiency with fewer production disturbances and an improved safety. Yet, it is still unusual that actions are taken to improve the situation. An alarm cleanup with general methods can shortly be described as taking advantage of the control systems built-in functions, the possibility to modify or create function blocks and fine-tune the settings in the alarm system. In this project, we make use of an intelligent software, Alarm Cleanup Toolbox, that simulate different signal processing methods and tries to find improved settings on all the signals in the process. This is a fast and cost-efficient way to improve the overall alarm situation, and lays a foundation for more advanced alarm systems. An alarm cleanup has been carried out at Flintraennan district heating plant in Malmoe, where various signal processing methods has been implemented in a parallel alarm system. This made it possible to compare the two systems under the same conditions. The result is very promising, and shows that a lot of improvements can be achieved with very little effort. An analysis of the alarm system at Vattenreningen (the water purification process) at Heleneholmsverket in Malmoe has been carried out. Alarm Cleanup Toolbox has, besides suggesting improved settings, also found logical errors in the alarm system. Here, no implementation was carried out and therefore the results are analytical, but they validate the efficiency of the general methods. The project has shown that an alarm cleanup with general methods is cost-efficient, and that the

  4. Is the Sequence of SuperAlarm Triggers More Predictive Than Sequence of the Currently Utilized Patient Monitor Alarms?

    Science.gov (United States)

    Bai, Yong; Do, Duc; Ding, Quan; Palacios, Jorge Arroyo; Shahriari, Yalda; Pelter, Michele M; Boyle, Noel; Fidler, Richard; Hu, Xiao

    2017-05-01

    Our previous studies have shown that "code blue" events can be predicted by SuperAlarm patterns that are multivariate combinations of monitor alarms and laboratory test results cooccurring frequently preceding the events but rarely among control patients. Deploying these patterns to the monitor data streams can generate SuperAlarm sequences. The objective of this study is to test the hypothesis that SuperAlarm sequences may contain more predictive sequential patterns than monitor alarms sequences. Monitor alarms and laboratory test results are extracted from a total of 254 adult coded and 2213 control patients. The training dataset is composed of subsequences that are sampled from complete sequences and then further represented as fixed-dimensional vectors by the term frequency inverse document frequency method. The information gain technique and weighted support vector machine are adopted to select the most relevant features and train a classifier to differentiate sequences between coded patients and control patients. Performances are assessed based on an independent dataset using three metrics: sensitivity of lead time (Sen L @T), alarm frequency reduction rate (AFRR), and work-up to detection ratio (WDR). The performance of 12-h-long sequences of SuperAlarm can yield a Sen L@2 of 93.33%, an AFRR of 87.28%, and a WDR of 3.01. At an AFRR = 87.28%, Sen L@2 for raw alarm sequences and discretized alarm sequences are 73.33% and 70.19%, respectively. At a WDR = 3.01, Sen L@2 are 49.88% and 43.33%. The results demonstrate that SuperAlarm sequences indeed outperform monitor alarm sequences and suggest that one can focus on sequential patterns from SuperAlarm sequences to develop more precise patient monitoring solutions.

  5. Development of a Simple Sound Activated Burglar Alarm System

    Directory of Open Access Journals (Sweden)

    Genesis Abah AGBO

    2006-07-01

    Full Text Available The paper presents the design, construction and testing of a simple sound activated burglar alarm. The principle of operation of this burglar alarm is simple. When the intensity of sound exceeds certain intensity, the alarm is triggered and the siren begins to operate. The speaker beeps and the flasher (light flashes. These actions thus alert the owner of the residence and/or security personnel of the presence of an intruder.

  6. Evaluation of nine different types of enuresis alarms.

    Science.gov (United States)

    Goel, K M; Thomson, R B; Gibb, E M; McAinsh, T F

    1984-01-01

    One hundred enuretic children were treated in closely supervised trial conditions with nine commonly used enuresis alarm systems available commercially in the United Kingdom. Although there was little difference between the systems in terms of their effectiveness in stopping bed wetting, parents preferred the Eastleigh and Urilarm De-Luxe models which had distinct advantages in respect of false alarms, breakdowns, and durability of pads. Enuresis alarms that perform poorly in these respects may lead to loss of enthusiasm and non-compliance. The systems vary widely in price, but a private buyer may find a cheaper alarm just as effective. PMID:6476872

  7. Community social alarm network in Slovenia.

    Science.gov (United States)

    Premik, M; Rudel, D

    1996-12-01

    The article deals with a case report on the technology transfer of the Lifeline community social alarm system to Slovenia. The main reason the project was initiated is the ageing of the Slovenian population (11% of the population is 65 or over). With this system we intend to support the public's wish to allow the elderly to remain in their own homes for as long as possible instead of placing them in institutional care. Between 1992 and 1995 the following results were achieved: the acceptability of the system in the social environment was increased; a pilot control centre in Ljubljana was established and has been operational for two-and-a-half years; a national dissemination plan was prepared; the integration of the programme into other information systems has been started. One of the main conclusions is that for the successful transfer of a technology which also affects social values in society, a social innovation must support the process.

  8. Aplikasi Sensor Cahaya Untuk Alarm Anti Pencuri

    Directory of Open Access Journals (Sweden)

    Asita Shoman Muzaki

    2011-11-01

    Full Text Available Kasus pencurian di rumah kosong yang ditinggal pergi oleh pemiliknya belakangan ini marak terjadi. Berangkat dari pemikiran ini penulis mencoba merancang alarm yang dapat mendeteksi pergerakan seseorang saat rumah dalam kondisi kosong, ditinggalkan oleh pemiliknya. Alat ini mempunyai prinsip kerja yaitu mendeteksi bayangan seseorang yang melewati titik tertentu. Perancangan dan pembuatan perangkat ini menggunakan sensor cahaya berupa LASER dan LDR yang dirangkai dengan transistor sebagai saklar otomatis serta LED dan telepon rumah untuk melakukan panggilan kepada nomor telepon pemilik rumah. Komponen yang dipakai dalam pembuatan perangkat ini antara lain IC LM7805, LASER pointer, resistor, transistor BC108, LED, relay dan telepon rumah. Perancangan dan pembuatan alat menggunakan software multisim 10.1 sebagai simulator rangkaian, dan software eagle 5.1.1 untuk mendesain jalur rangkaian pada papan PCB. Saat cahaya LASER tidak sampai ke LDR karena terhalang oleh sesuatu, maka rangkaian output yang berupa indikator LED dan panggilan dari telepon rumah akan aktif

  9. [The alarming increase of incapacity for work].

    Science.gov (United States)

    Thibaut, P

    2013-09-01

    The alarming increase of incapacity for work The increase of incapacity for work in Belgium and in Europe is not a new phenomenon but only the transposition of an experience already lived on others continents (Canada--USA). The bio-psycho-social model proves to be, on the international level, as the more efficient view for the understanding of the mechanisms production of the disability and therefore of the incapacity for work. Following this approach, the chronic pain is the result of the dynamic interaction between physiological, psychological and social factors. It mentions also an existing link between the pain and the depression itself being a determining factor in the persistence of the incapacity for work. The bio-psycho-social model can only be conceived in the interdisciplinary approach, and will for sure allow to optimize the support and the use of medicines with a painkiller and depressive aim. The socio-economic impact created represents actually a real health problem.

  10. Alarm management for process control a best-practice guide for design, implementation, and use of industrial alarm systems

    CERN Document Server

    Rothenberg, Douglas H

    2014-01-01

    No modern industrial enterprise, particularly in such areas as chemical processing, can operate without a secure, and reliable, network of automated monitors and controls. And those operations need alarm systems to alert engineers and managers the moment anything goes wrong or needs attention. This book, by one of the world's leading experts on industrial alarm systems, will provide A to Z coverage of designing, implementing, and maintaining an effective alarm network.

  11. Smoke alarm installation and function in inner London council housing

    Science.gov (United States)

    DiGuiseppi, C.; Roberts, I.; Speirs, N.

    1999-01-01

    AIM—To determine the prevalence of and predictors for installed, functioning smoke alarms in council (public) housing in a low income, multi-ethnic urban area.
DESIGN—Cross sectional study.
SETTING—40 materially deprived electoral wards in two inner London boroughs.
PARTICIPANTS—Occupants of 315 addresses randomly selected from council housing lists, with 75% response rate.
MAIN OUTCOME MEASURES—Installation and function of smoke alarms based on inspection and testing.
RESULTS—39% (95% confidence interval (CI) 33% to 46%) of council tenants owned a smoke alarm, 31% (95% CI 25% to 38%) had an installed alarm (of which 54% were correctly installed), and 16% (95% CI 12% to 22%) had at least one installed, functioning alarm. Alarms most commonly failed because they lacked batteries (72%). In multivariate modelling, having an installed, functioning alarm was most strongly associated with living in a house versus a flat (apartment) (odds ratio (OR) 3.2, 95% CI 1.1 to 10.0), having two resident adults versus one (OR 2.8, 95% CI 1.2 to 6.5), and recognising stills from a Home Office television smoke alarm campaign (OR 2.4, 95% CI 1.1 to 5.5).
CONCLUSIONS—Fires are a leading cause of child injury and death, particularly among those younger than 5 years of age and those in social classes IV and V. Smoke alarms are associated with a significantly reduced risk of death in residential fires, and are more protective in households with young children. Few council properties in a multi-ethnic, materially deprived urban area had any installed, functioning smoke alarms, despite a high risk of residential fires and fire related injuries in such areas. Effective methods to increase the prevalence of installed and functioning alarms must be identified.

 PMID:10519711

  12. Enriched vibrational resonance in certain discrete systems

    Indian Academy of Sciences (India)

    We wish to report the occurrence of vibrational resonance in certain discrete systems like sine square map and sine circle map, in a unique fashion, comprising of multiple resonant peaks which pave the way for enrichment. As the systems of our choice are capable of exhibiting vibrational resonance behaviour unlike the ...

  13. Capability approach

    DEFF Research Database (Denmark)

    Jensen, Niels Rosendal; Kjeldsen, Christian Christrup

    Lærebogen er den første samlede danske præsentation af den af Amartya Sen og Martha Nussbaum udviklede Capability Approach. Bogen indeholder en præsentation og diskussion af Sen og Nussbaums teoretiske platform. I bogen indgår eksempler fra såvel uddannelse/uddannelsespolitik, pædagogik og omsorg....

  14. ENTREPRENEURIAL CAPABILITIES

    DEFF Research Database (Denmark)

    Rasmussen, Lauge Baungaard; Nielsen, Thorkild

    2003-01-01

    The aim of this article is to analyse entrepreneurship from an action research perspective. What is entrepreneurship about? Which are the fundamental capabilities and processes of entrepreneurship? To answer these questions the article includes a case study of a Danish entrepreneur and his networks...

  15. Alarm calls of Bronze Mannikins communicate predator size to ...

    African Journals Online (AJOL)

    These groups were exposed to latex terrestrial snakes and mounted aerial raptors, and their alarm calls and predator response behaviours recorded. The Bronze Mannikins were able to discriminate between predators of different sizes, and increased their calling rate and decreased the end frequency of the alarm call in ...

  16. An integrated alarm display design in digital nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Xiaojun [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Li, Zhizhong, E-mail: zzli@tsinghua.edu.cn [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Song, Fei; Sang, Wei [Shanghai Nuclear Engineering Research and Design Institute, Shanghai 200233 (China)

    2016-08-15

    Highlights: • The effect of integrating system information into alarm displays in ACR was explored. • A bar-based integrated alarm display design was validated through a lab experiment. • The bar-based integrated design was preferred in detecting parameter trends. • The bar-based integrated design helped better understanding of the current scenario. - Abstract: In main control rooms of nuclear power plants (NPPs), operators often have to frequently switch their attention between alarm displays and system information displays to incorporate information from different screens. In this study, we proposed the idea of integrating system information into alarm displays. A bar-based integrated design of alarm display was proposed, and it was compared against a tile-based integrated design, and a traditional separate design through a lab experiment. To verify the idea of integration, forty-eight participants were randomly assigned to the three integration conditions to perform basic alarm response tasks, and their situation awareness levels and subjective evaluations were collected. The results indicated that the participants preferred the idea of integrating system information into alarm displays. Besides, the bar-based integrated display supported higher correct rate of answers to situation awareness questions related to the developing scenario than the tile-based integrated design. The idea of integrating system information into alarm displays merits further research and may be applicable to other safety–critical industries.

  17. 46 CFR 28.250 - High water alarms.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a) A...

  18. Statistical Study of False Alarms of Geomagnetic Storms

    DEFF Research Database (Denmark)

    Leer, Kristoffer; Vennerstrøm, Susanne; Veronig, A.

    alarms is considered as an important factor when forecasting geomagnetic storms. It would therefore be very helpful if there were a signature in the solar data that could indicate that a CME is a false alarm. The strength and position of associated flares have been considered as possible candidates...

  19. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Science.gov (United States)

    2010-10-01

    ..., the mixture pressure is reduced to one-half of the alarm's maximum design pressure. If the alarm has a... minutes and then with a mixture of Test Fluid A and water in the following concentrations: 0 ppm, 15 ppm, and the highest oil concentration that can be read on the monitor. A sample of the mixture causing...

  20. Criticality accident alarm system at the Fernald Environmental Management Project

    Energy Technology Data Exchange (ETDEWEB)

    Marble, R.C.; Brown, T.D.; Wooldridge, J.C.

    1994-06-01

    The purpose of this paper is to give a description of the Criticality Accident Alarm System (CAAS) presently installed at the Fernald Environmental Management Project (FEMP) for monitoring areas requiring criticality controls, and some of the concerns associated with the operation of this system. The system at the FEMP is known as the Radiation Detection Alarm (RDA) System.

  1. Successful Use of the Nocturnal Urine Alarm for Diurnal Enuresis.

    Science.gov (United States)

    Friman, Patrick C.; Vollmer, Dennis

    1995-01-01

    A urine alarm, typically used to treat nocturnal enuresis, was effectively used to treat diurnal enuresis in a 15-year-old female with depression, attention deficit hyperactivity disorder, and conduct disorder. The study indicated that the alarm eliminated wetting in both treatment phases and that continence was maintained at three-month and…

  2. 46 CFR 131.805 - General alarm bell, switch.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in the...

  3. 33 CFR 157.440 - Autopilot alarm or indicator.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Autopilot alarm or indicator. 157.440 Section 157.440 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... § 157.440 Autopilot alarm or indicator. (a) A tankship owner or operator shall ensure that each...

  4. A breathing circuit alarm system based on neural networks.

    Science.gov (United States)

    Orr, J A; Westenskow, D R

    1994-03-01

    The objectives of our study were (1) to implement intelligent respiratory alarms with a neural network; and (2) to increase alarm specificity and decrease false-alarm rates compared with current alarms. We trained a neural network to recognize 13 faults in an anesthesia breathing circuit. The system extracted 30 breath-to-breath features from the airway CO2, flow, and pressure signals. We created training data for the network by introducing 13 faults repeatedly in 5 dogs (616 total faults). We used the data to train the neural network using the backward error propagation algorithm. In animals, the trained network reported the alarms correctly for 95.0% of the faults when tested during controlled ventilation, and for 86.9% of the faults during spontaneous breathing. When tested in the operating room, the system found and correctly reported 54 of 57 faults that occurred during 43.6 hr of use. The alarm system produced a total of 74 false alarms during 43.6 hr of monitoring. Neural networks may be useful in creating intelligent anesthesia alarm systems.

  5. Vibrating minds

    CERN Document Server

    2009-01-01

    Ed Witten is one of the leading scientists in the field of string theory, the theory that describes elementary particles as vibrating strings. This week he leaves CERN after having spent a few months here on sabbatical. His wish is that the LHC will unveil supersymmetry.

  6. Alarm systems a guide to design, management and procurement

    CERN Document Server

    Engineering Equipment and Materials Users' Association. London

    2013-01-01

    Alarm systems form an essential part of the operator interfaces to large modern industrial facilities. They provide vital support to the operators by warning them of situations that need their attention and have an important role in preventing, controlling and mitigating the effects of abnormal situations. Since it was first published in 1999, EEMUA 191 has become the globally accepted and leading guide to good practice for all aspects of alarm systems. The guide, developed by users of alarm systems with input from the GB Health and Safety Executive, gives comprehensive guidance on designing, managing and procuring an effective alarm system. The new Third Edition has been comprehensively updated and includes guidance on implementing the alarm management philosophy in practice; applications in geographically distributed processes; and performance metrics and KPIs.

  7. Development and evaluation of new coupling system for lower limb prostheses with acoustic alarm system.

    Science.gov (United States)

    Eshraghi, Arezoo; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ahmadian, Jalil; Rahmati, Bizhan; Abas, Wan Abu Bakar Wan

    2013-01-01

    Individuals with lower limb amputation need a secure suspension system for their prosthetic devices. A new coupling system was developed that is capable of suspending the prosthesis. The system's safety is ensured through an acoustic alarm system. This article explains how the system works and provides an in vivo evaluation of the device with regard to pistoning during walking. The system was designed to be used with silicone liners and is based on the requirements of prosthetic suspension systems. Mechanical testing was performed using a universal testing machine. The pistoning during walking was measured using a motion analysis system. The new coupling device produced significantly less pistoning compared to a common suspension system (pin/lock). The safety alarm system would buzz if the suspension was going to fail. The new coupling system could securely suspend the prostheses in transtibial amputees and produced less vertical movement than the pin/lock system.

  8. Smart container UWB sensor system for situational awareness of intrusion alarms

    Science.gov (United States)

    Romero, Carlos E.; Haugen, Peter C.; Zumstein, James M.; Leach, Jr., Richard R.; Vigars, Mark L.

    2013-06-11

    An in-container monitoring sensor system is based on an UWB radar intrusion detector positioned in a container and having a range gate set to the farthest wall of the container from the detector. Multipath reflections within the container make every point on or in the container appear to be at the range gate, allowing intrusion detection anywhere in the container. The system also includes other sensors to provide false alarm discrimination, and may include other sensors to monitor other parameters, e.g. radiation. The sensor system also includes a control subsystem for controlling system operation. Communications and information extraction capability may also be included. A method of detecting intrusion into a container uses UWB radar, and may also include false alarm discrimination. A secure container has an UWB based monitoring system

  9. From alarm systems to smart houses.

    Science.gov (United States)

    Vlaskamp, F J

    1992-01-01

    The percentage of senior citizens in the Netherlands will rise in coming years. The expected percentage for the year 2010 of persons over age 65 in the total population is 15%. More persons over age 65 than ever before will continue to live in their own environment. Emergency response systems (ERS) can support independent living. The most common type of organization distributing ERS is a small, partly subsidized local alarm organization run by a social welfare office for the elderly. Government subsidy has been reduced in recent years which has motivated small organizations to join together into larger regional organizations in order to get a more solid financial base. On the other hand new semi-commercial and commercial organizations have come into being. These developments are part of the growing importance of home care, leading to more medical applications of ERS. User satisfaction with ERS is high. Portable triggers can enhance the effectiveness of the system. However, many users do not wear the portable trigger when feeling well. Future technical developments will result in multifunctionality of ERS-devices. In the long term the hardware of today will be integrated in a multimedia home terminal replacing the telephone. The portable trigger will remain the only specific hardware at home for ERS.

  10. 47 CFR 10.530 - Common vibration cadence.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Common vibration cadence. 10.530 Section 10.530... § 10.530 Common vibration cadence. A Participating CMS Provider and equipment manufacturers may only market devices for public use under part 10 that include a vibration cadence capability that meets the...

  11. Acoustic structures in the alarm calls of Gunnison's prairie dogs.

    Science.gov (United States)

    Slobodchikoff, C N; Placer, J

    2006-05-01

    Acoustic structures of sound in Gunnison's prairie dog alarm calls are described, showing how these acoustic structures may encode information about three different predator species (red-tailed hawk-Buteo jamaicensis; domestic dog-Canis familaris; and coyote-Canis latrans). By dividing each alarm call into 25 equal-sized partitions and using resonant frequencies within each partition, commonly occurring acoustic structures were identified as components of alarm calls for the three predators. Although most of the acoustic structures appeared in alarm calls elicited by all three predator species, the frequency of occurrence of these acoustic structures varied among the alarm calls for the different predators, suggesting that these structures encode identifying information for each of the predators. A classification analysis of alarm calls elicited by each of the three predators showed that acoustic structures could correctly classify 67% of the calls elicited by domestic dogs, 73% of the calls elicited by coyotes, and 99% of the calls elicited by red-tailed hawks. The different distributions of acoustic structures associated with alarm calls for the three predator species suggest a duality of function, one of the design elements of language listed by Hockett [in Animal Sounds and Communication, edited by W. E. Lanyon and W. N. Tavolga (American Institute of Biological Sciences, Washington, DC, 1960), pp. 392-430].

  12. Computational Human Performance Modeling For Alarm System Design

    Energy Technology Data Exchange (ETDEWEB)

    Jacques Hugo

    2012-07-01

    The introduction of new technologies like adaptive automation systems and advanced alarms processing and presentation techniques in nuclear power plants is already having an impact on the safety and effectiveness of plant operations and also the role of the control room operator. This impact is expected to escalate dramatically as more and more nuclear power utilities embark on upgrade projects in order to extend the lifetime of their plants. One of the most visible impacts in control rooms will be the need to replace aging alarm systems. Because most of these alarm systems use obsolete technologies, the methods, techniques and tools that were used to design the previous generation of alarm system designs are no longer effective and need to be updated. The same applies to the need to analyze and redefine operators’ alarm handling tasks. In the past, methods for analyzing human tasks and workload have relied on crude, paper-based methods that often lacked traceability. New approaches are needed to allow analysts to model and represent the new concepts of alarm operation and human-system interaction. State-of-the-art task simulation tools are now available that offer a cost-effective and efficient method for examining the effect of operator performance in different conditions and operational scenarios. A discrete event simulation system was used by human factors researchers at the Idaho National Laboratory to develop a generic alarm handling model to examine the effect of operator performance with simulated modern alarm system. It allowed analysts to evaluate alarm generation patterns as well as critical task times and human workload predicted by the system.

  13. Coupled rotor/airframe vibration analysis

    Science.gov (United States)

    Sopher, R.; Studwell, R. E.; Cassarino, S.; Kottapalli, S. B. R.

    1982-01-01

    A coupled rotor/airframe vibration analysis developed as a design tool for predicting helicopter vibrations and a research tool to quantify the effects of structural properties, aerodynamic interactions, and vibration reduction devices on vehicle vibration levels is described. The analysis consists of a base program utilizing an impedance matching technique to represent the coupled rotor/airframe dynamics of the system supported by inputs from several external programs supplying sophisticated rotor and airframe aerodynamic and structural dynamic representation. The theoretical background, computer program capabilities and limited correlation results are presented in this report. Correlation results using scale model wind tunnel results show that the analysis can adequately predict trends of vibration variations with airspeed and higher harmonic control effects. Predictions of absolute values of vibration levels were found to be very sensitive to modal characteristics and results were not representative of measured values.

  14. Honey Bee Inhibitory Signaling Is Tuned to Threat Severity and Can Act as a Colony Alarm Signal.

    Science.gov (United States)

    Tan, Ken; Dong, Shihao; Li, Xinyu; Liu, Xiwen; Wang, Chao; Li, Jianjun; Nieh, James C

    2016-03-01

    Alarm communication is a key adaptation that helps social groups resist predation and rally defenses. In Asia, the world's largest hornet, Vespa mandarinia, and the smaller hornet, Vespa velutina, prey upon foragers and nests of the Asian honey bee, Apis cerana. We attacked foragers and colony nest entrances with these predators and provide the first evidence, in social insects, of an alarm signal that encodes graded danger and attack context. We show that, like Apis mellifera, A. cerana possesses a vibrational "stop signal," which can be triggered by predator attacks upon foragers and inhibits waggle dancing. Large hornet attacks were more dangerous and resulted in higher bee mortality. Per attack at the colony level, large hornets elicited more stop signals than small hornets. Unexpectedly, stop signals elicited by large hornets (SS large hornet) had a significantly higher vibrational fundamental frequency than those elicited by small hornets (SS small hornet) and were more effective at inhibiting waggle dancing. Stop signals resulting from attacks upon the nest entrance (SS nest) were produced by foragers and guards and were significantly longer in pulse duration than stop signals elicited by attacks upon foragers (SS forager). Unlike SS forager, SS nest were targeted at dancing and non-dancing foragers and had the common effect, tuned to hornet threat level, of inhibiting bee departures from the safe interior of the nest. Meanwhile, nest defenders were triggered by the bee alarm pheromone and live hornet presence to heat-ball the hornet. In A. cerana, sophisticated recruitment communication that encodes food location, the waggle dance, is therefore matched with an inhibitory/alarm signal that encodes information about the context of danger and its threat level.

  15. Honey Bee Inhibitory Signaling Is Tuned to Threat Severity and Can Act as a Colony Alarm Signal.

    Directory of Open Access Journals (Sweden)

    Ken Tan

    2016-03-01

    Full Text Available Alarm communication is a key adaptation that helps social groups resist predation and rally defenses. In Asia, the world's largest hornet, Vespa mandarinia, and the smaller hornet, Vespa velutina, prey upon foragers and nests of the Asian honey bee, Apis cerana. We attacked foragers and colony nest entrances with these predators and provide the first evidence, in social insects, of an alarm signal that encodes graded danger and attack context. We show that, like Apis mellifera, A. cerana possesses a vibrational "stop signal," which can be triggered by predator attacks upon foragers and inhibits waggle dancing. Large hornet attacks were more dangerous and resulted in higher bee mortality. Per attack at the colony level, large hornets elicited more stop signals than small hornets. Unexpectedly, stop signals elicited by large hornets (SS large hornet had a significantly higher vibrational fundamental frequency than those elicited by small hornets (SS small hornet and were more effective at inhibiting waggle dancing. Stop signals resulting from attacks upon the nest entrance (SS nest were produced by foragers and guards and were significantly longer in pulse duration than stop signals elicited by attacks upon foragers (SS forager. Unlike SS forager, SS nest were targeted at dancing and non-dancing foragers and had the common effect, tuned to hornet threat level, of inhibiting bee departures from the safe interior of the nest. Meanwhile, nest defenders were triggered by the bee alarm pheromone and live hornet presence to heat-ball the hornet. In A. cerana, sophisticated recruitment communication that encodes food location, the waggle dance, is therefore matched with an inhibitory/alarm signal that encodes information about the context of danger and its threat level.

  16. New Concept For Alarm Structure And Management In Dcs Systems

    Directory of Open Access Journals (Sweden)

    Mohammed Hegazy

    2015-08-01

    Full Text Available The objective of this paper is to set new standard for good design and best practice to applied when any DCS ManufacturesSuppliers configure process alarm system in any oil refining oil and gas production gas-handling facilities gasification plant or any chemical processing plant and thereby to optimizeminimize unnecessary alarms from reporting to operator workstations CAD Control Alarm Display. These views based on the experience acquired and implemented during involvement with the commissioning and startup of two DCS projects in Mina Al-Ahmadi Refinery Kuwait.

  17. Pickin’ up good vibrations

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    In preparation for the civil engineering work on the HL-LHC, vibration measurements were carried out at the LHC’s Point 1 last month. These measurements will help evaluate how civil engineering work could impact the beam, and will provide crucial details about the site’s geological make-up before construction begins.   A seismic truck at Point 1 generated wave-like vibrations measured by EN/MME. From carrying out R&D to produce state-of-the-art magnets to developing innovative, robust materials capable of withstanding beam impact, the HL-LHC is a multi-faceted project involving many groups and teams across CERN’s departments. It was in this framework that the project management mandated CERN's Mechanical and Materials Engineering (EN/MME) group to measure the propagation of vibrations around Point 1. Their question: can civil engineering work for the HL-LHC – the bulk of which is scheduled for LS2 – begin while the LHC is running? Alth...

  18. Microcontroller-based Vehicle Security System with Tracking Capability using GSM and GPS Technologies

    Directory of Open Access Journals (Sweden)

    Engr. Orven F. Mendoza

    2017-05-01

    Full Text Available The security of vehicles is ext remely essential for vehicle owners especially to those whose hard - earned income was used to avail of one or simply, its loss would mean inconveniences to family and work. With these, it becomes the major problem of every vehicle owner. This thesis, Microc ontroller - based Vehicle Security System with Tracking Capability using GSM and GPS Technologies, is a system that can be used to increase vehicle security, as it can track location of missing vehicle, and help authorities have credible evidence that the ve hicle is stolen. The project uses the Global System for Mobile (GSM and the Global Positioning System (GPS technology, which includes the use of GPS receiver module, GSM module, and microcontroller as its primary components. It also uses a vibration sens or that senses vehicle movement and a buzzer that sends an alarm when sensors are triggered. A confirmation message is sent to the vehicle owner of the vehicle by the device. The system also features capability of tracking the location of the vehicle with the help of the GPS receiver which gives data to the location of the vehicle by way of coordinates. These coordinates provide exact location of the motor vehicle. The SMS message that the vehicle owner will send to the device attached to the vehicle should follow correct format of limitation for successful use and the use of the four character password followed by the command. The command is for power switching or activating automatically the key switch, engine and alarm. If not observed, the device would not work. The project is deemed to provide vehicle owners the security of their vehicle. The system will not only ensure vehicle security but also lessen the threats on vehicles.

  19. Nuthatches eavesdrop on variations in heterospecific chickadee mobbing alarm calls

    Science.gov (United States)

    Templeton, Christopher N.; Greene, Erick

    2007-01-01

    Many animals recognize the alarm calls produced by other species, but the amount of information they glean from these eavesdropped signals is unknown. We previously showed that black-capped chickadees (Poecile atricapillus) have a sophisticated alarm call system in which they encode complex information about the size and risk of potential predators in variations of a single type of mobbing alarm call. Here we show experimentally that red-breasted nuthatches (Sitta canadensis) respond appropriately to subtle variations of these heterospecific “chick-a-dee” alarm calls, thereby evidencing that they have gained important information about potential predators in their environment. This study demonstrates a previously unsuspected level of discrimination in intertaxon eavesdropping. PMID:17372225

  20. A weighted dissimilarity index to isolate faults during alarm floods

    CERN Document Server

    Charbonnier, S; Gayet, P

    2015-01-01

    A fault-isolation method based on pattern matching using the alarm lists raised by the SCADA system during an alarm flood is proposed. A training set composed of faults is used to create fault templates. Alarm vectors generated by unknown faults are classified by comparing them with the fault templates using an original weighted dissimilarity index that increases the influence of the few alarms relevant to diagnose the fault. Different decision strategies are proposed to support the operator in his decision making. The performances are evaluated on two sets of data: an artificial set and a set obtained from a highly realistic simulator of the CERN Large Hadron Collider process connected to the real CERN SCADA system.

  1. Patient characteristics associated with false arrhythmia alarms in intensive care

    Directory of Open Access Journals (Sweden)

    Harris PR

    2017-04-01

    Full Text Available Patricia R Harris,1,2 Jessica K Zègre-Hemsey,3,4 Daniel Schindler,5 Yong Bai,6 Michele M Pelter,2,7 Xiao Hu2,8 1Department of Nursing, School of Health and Natural Sciences, Dominican University of California, San Rafael, 2Department of Physiological Nursing, School of Nursing, University of California, San Francisco, CA, 3School of Nursing, 4Department of Emergency Medicine, School of Medicine, University of North Carolina at Chapel Hill, NC, 5Intensive Care Unit, The Neuroscience Center, Sutter Eden Medical Center, Castro Valley, 6Hu Research Laboratory, Department of Physiological Nursing, School of Nursing, University of California, San Francisco, 7ECG Monitoring Research Lab, Department of Physiological Nursing, School of Nursing, 8Physiological Nursing and Neurological Surgery, Affiliate Faculty of Institute for Computational Health Sciences Core Faculty UCB/UCSF Joint Bio-Engineering Graduate Program, University of California, San Francisco, CA, USA Introduction: A high rate of false arrhythmia alarms in the intensive care unit (ICU leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. Objective: The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. Methods: This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and

  2. ARC Code TI: Optimal Alarm System Design and Implementation

    Data.gov (United States)

    National Aeronautics and Space Administration — An optimal alarm system can robustly predict a level-crossing event that is specified over a fixed prediction horizon. The code contained in this packages provides...

  3. Wireless intelligent alarm technology with pyroelectric infrared sensor

    Science.gov (United States)

    Chen, Xiao

    2009-07-01

    Aiming at the defects of monitoring conducted by man in the conventional practice, we study the passive intelligent automatic alarm technology based on the pyroelectric infrared sensor and wireless communication technology. The designed passive infrared wireless alarm is composed of pyroelectric infrared sensors, infrared special chip BISS0001 and their peripheral circuits. When someone enters into the detecting and monitoring range, the alarm will detect the infrared ray of the human radiation by the contactless form and detect the signals of circuit output. Then it translates them into low frequency signals relative with human sports speed, distance and direction, produce corresponding output signals through amplifying by the back state controller, switch on the work power of the wireless transmitting circuit and make it emit the alarm signals. The system enhances the monitoring level and effects and possesses many advantages such as wide detecting range, long detecting distance and high reliability.

  4. Frog Swarms: Earthquake Precursors or False Alarms?

    Directory of Open Access Journals (Sweden)

    Rachel A. Grant

    2013-10-01

    Full Text Available In short-term earthquake risk forecasting, the avoidance of false alarms is of utmost importance to preclude the possibility of unnecessary panic among populations in seismic hazard areas. Unusual animal behaviour prior to earthquakes has been reported for millennia but has rarely been scientifically documented. Recently large migrations or unusual behaviour of amphibians have been linked to large earthquakes, and media reports of large frog and toad migrations in areas of high seismic risk such as Greece and China have led to fears of a subsequent large earthquake. However, at certain times of year large migrations are part of the normal behavioural repertoire of amphibians. News reports of “frog swarms” from 1850 to the present day were examined for evidence that this behaviour is a precursor to large earthquakes. It was found that only two of 28 reported frog swarms preceded large earthquakes (Sichuan province, China in 2008 and 2010. All of the reported mass migrations of amphibians occurred in late spring, summer and autumn and appeared to relate to small juvenile anurans (frogs and toads. It was concluded that most reported “frog swarms” are actually normal behaviour, probably caused by juvenile animals migrating away from their breeding pond, after a fruitful reproductive season. As amphibian populations undergo large fluctuations in numbers from year to year, this phenomenon will not occur on a yearly basis but will depend on successful reproduction, which is related to numerous climatic and geophysical factors. Hence, most large swarms of amphibians, particularly those involving very small frogs and occurring in late spring or summer, are not unusual and should not be considered earthquake precursors. In addition, it is likely that reports of several mass migration of small toads prior to the Great Sichuan Earthquake in 2008 were not linked to the subsequent M = 7.9 event (some occurred at a great distance from the epicentre

  5. Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue.

    Science.gov (United States)

    Sowan, Azizeh Khaled; Tarriela, Albert Fajardo; Gomez, Tiffany Michelle; Reed, Charles Calhoun; Rapp, Kami Marie

    2015-03-16

    Intensive care units (ICUs) are complex work environments where false alarms occur more frequently than on non-critical care units. The Joint Commission National Patient Safety Goal .06.01.01 targeted improving the safety of clinical alarm systems and required health care facilities to establish alarm systems safety as a hospital priority by July 2014. An important initial step toward this requirement is identifying ICU nurses' perceptions and common clinical practices toward clinical alarms, where little information is available. Our aim was to determine perceptions and practices of transplant/cardiac ICU (TCICU) nurses toward clinical alarms and benchmark the results against the 2011 Healthcare Technology Foundation's (HTF) Clinical Alarms Committee Survey. A quality improvement project was conducted on a 20-bed TCICU with 39 full- and part-time nurses. Nurses were surveyed about their perceptions and attitudes toward and practices on clinical alarms using an adapted HTF clinical alarms survey. Results were compared to the 2011 HTF data. Correlations among variables were examined. All TCICU nurses provided usable responses (N=39, 100%). Almost all nurses (95%-98%) believed that false alarms are frequent, disrupt care, and reduce trust in alarm systems, causing nurses to inappropriately disable them. Unlike the 2011 HTF clinical alarms survey results, a significantly higher percentage of our TCICU nurses believed that existing devices are complex, questioned the ability and adequacy of the new monitoring systems to solve alarm management issues, pointed to the lack of prompt response to alarms, and indicated the lack of clinical policy on alarm management (Ppractices related to clinical alarms are key elements for designing contextually sensitive quality initiatives to fight alarm fatigue. Alarm management in ICUs is a multidimensional complex process involving usability of monitoring devices, and unit, clinicians, training, and policy-related factors. This

  6. How Drivers Respond to Alarms Adapted to Their Braking Behaviour?

    Science.gov (United States)

    Abe, Genya; Itoh, Makoto

    Determining appropriate alarm timing for Forward Collision Warning Systems (FCWS) may play an important role in enhancing system acceptance by drivers. It is not always true that a common alarm trigger logic is suitable for all drivers, because presented alarms may be differently viewed for each driver, i.e., paying attention or requiring appropriate actions. The current study focused on adaptive alarm timing which was adjusted in response to braking behaviour for collision avoidance for the individual. In Experiment I, the braking performance of individual driver was measured repeatedly to assess the variation of each performance. We utilised the following two indices: elapsed time from the deceleration of the lead car to release of the accelerator (accelerator release time) and elapsed time to application of the brakes (braking response time). Two alarm timings were then determined based on these two indices: (i) the median of the accelerator release time of the driver and (ii) the median of the braking response time of the driver. Experiment II compared the two alarm timings for each driver in order to investigate which timing is more appropriate for enhancing driver trust in the driver-adaptive FCWS and the system effectiveness. The results showed that the timing of the accelerator release time increased the trust ratings more than the timing of braking response. The timing of the braking response time induced a longer response time to application of the brakes. Moreover, the degree to which the response time was longer depended on alarm timing preference of the driver. The possible benefit and drawback of driver-adaptive alarm timing are discussed.

  7. [Citalopram, escitalopram and prolonged QT: warning or alarm?].

    Science.gov (United States)

    Alvarez, Enric; Vieira, Sara; Garcia-Moll, Xavier

    2014-01-01

    The alerts issued by regulatory agencies on the potential cardiac toxicity of citalopram and escitalopram have caused alarm among clinicians. A review of the data concerning this topic shows that the alarm should be limited to patients with a history of syncope or poisoning. As a precautionary measure, an electrocardiogram should be performed on elderly patients. Copyright © 2013 SEP y SEPB. Published by Elsevier España. All rights reserved.

  8. Advanced Alarm Systems: Revision of Guidance and Its Technical Basis

    Science.gov (United States)

    2000-11-01

    legend; • Plant system or component involved (e.g., reactor coolant pump A); • Parameter involved (e.g., temperature , pressure, voltage); • Status...and Layout .. 4-31 4.3 Human Performance Issues 4-31 5 DISCUSSION 5-1 6 REFERENCES 6 -1 APPENDDC A Alarm System Characterization A-l APPENDIX...Pressurized Water Reactor (Westinghouse) APWR Advanced Pressurized Water Reactor (Mitsubishi) ARP alarm response procedure CAMLS CANDU Annunciation Message

  9. Urban vibrations

    DEFF Research Database (Denmark)

    Morrison, Ann; Knudsen, L.; Andersen, Hans Jørgen

    2012-01-01

      lab   studies   in   that   we   found   a   decreased   detection   rate   in   busy   environments.   Here   we   test   with   a   much   larger   sample   and   age   range,   and   contribute   with   the   first   vibration  sensitivity  testing  outside  the  lab  in  an  urban   public...

  10. Sun-glint false alarm mitigation in a maritime scenario

    Science.gov (United States)

    Rossi, Alessandro; Riccobono, Aldo; Landini, Stefano

    2014-10-01

    Airborne hyperspectral imaging can be exploited to detect anomalous objects in the maritime scenario. Due to the objects high contrast with respect to the sea surface, detection can be easily accomplished by means of local anomaly detectors, such as the well-known Reed-Xiaoli (RX) algorithm. During the development of a real-time system for the detection of anomalous pixels, it has been noticed that the performance of detection is deeply affected by the presence of sun-glint. The reflection on the sea surface of the solar radiation produces a high density of alarms, that makes challenging the task of detecting the objects of interest. In this paper, it is introduced a strategy aimed at discriminating the sun-glint false alarms from the effective alarms related to targets of potential interest. False alarms due to glint are mitigated performing a local spatio-spectral analysis on each alarm furnished by the anomaly detector. The technique has been tested on hyperspectral images collected during a measurement campaign carried out near Pisa, Italy. The Selex ES SIMGA hyperspectral sensor was mounted on board of an airplane to collect high spectral resolution images in both the VNIR and SWIR spectral channels. Several experiments were carried out, setting up scenarios with small man-made objects deployed on the sea surface, so as to simulate search and rescue operations. The results have highlighted the effectiveness of the proposed solution in terms of mitigation of false alarms due to sun-glints on the maritime scenario.

  11. Panic, suffocation false alarms, separation anxiety and endogenous opioids.

    Science.gov (United States)

    Preter, Maurice; Klein, Donald F

    2008-04-01

    This review paper presents an amplification of the suffocation false alarm theory (SFA) of spontaneous panic [Klein DF (1993). False suffocation alarms, spontaneous panics, and related conditions. An integrative hypothesis. Arch Gen Psychiatry; 50:306-17.]. SFA postulates the existence of an evolved physiologic suffocation alarm system that monitors information about potential suffocation. Panic attacks maladaptively occur when the alarm is erroneously triggered. That panic is distinct from Cannon's emergency fear response and Selye's General Alarm Syndrome is shown by the prominence of intense air hunger during these attacks. Further, panic sufferers have chronic sighing abnormalities outside of the acute attack. Another basic physiologic distinction between fear and panic is the counter-intuitive lack of hypothalamic-pituitary-adrenal (HPA) activation in panic. Understanding panic as provoked by indicators of potential suffocation, such as fluctuations in pCO(2) and brain lactate, as well as environmental circumstances fits the observed respiratory abnormalities. However, that sudden loss, bereavement and childhood separation anxiety are also antecedents of "spontaneous" panic requires an integrative explanation. Because of the opioid system's central regulatory role in both disordered breathing and separation distress, we detail the role of opioidergic dysfunction in decreasing the suffocation alarm threshold. We present results from our laboratory where the naloxone-lactate challenge in normals produces supportive evidence for the endorphinergic defect hypothesis in the form of a distress episode of specific tidal volume hyperventilation paralleling challenge-produced and clinical panic.

  12. Determining the alarm signal in pulse interferometric fibre sensor by two independent criteria

    Science.gov (United States)

    Życzkowski, Marek; Karol, Mateusz

    2017-04-01

    The article describes the construction and operation principle of the fibre optic pulse interferometer, which allows detection of mechanical disorders in fibre optic transmission line. Operation of this system is based on the optical pulses interference. Configuration of the system allows stable work of pulse interferometer over distances of several kilometres, with compensation impact of environmental conditions. Unique system detection capabilities obtained by using two independent criteria for alarm signal excitation. The aim of the research was to determine the usefulness of the proposed system to protection of information transmission via fibre-optic transmission networks.

  13. Iranian rocket launch alarms the West

    Science.gov (United States)

    Jeandron, Michelle

    2008-03-01

    Iran came a step closer to becoming a space-faring nation last month, with the successful test of a rocket capable of carrying a satellite into orbit and the opening of a new space centre. Western commentators, however, have expressed scepticism about whether Iran really does have the technology to successfully launch a satellite, suggesting instead that the country is more interested in developing intercontinental ballistic missiles, which require similarly powerful rockets.

  14. Evaluation of Bus Vibration Comfort Based on Passenger Crowdsourcing Mode

    Directory of Open Access Journals (Sweden)

    Hong Zhao

    2016-01-01

    Full Text Available Vibration comfort is an important factor affecting the quality of service (QoS of bus. In order to make people involved in supervising bus’s vibration comfort and improve passengers’ riding experience, a novel mode of passenger crowdsourcing is introduced. In this paper, comfort degree of bus vibration is calculated from bus’s vibration signals collected by passengers’ smartphones and sent through WiFi to the Boa web server which shows the vibration comfort on the LCD deployed in bus and maybe trigger alarm lamp when the vibration is beyond the threshold. Three challenges here have been overcome: firstly, space coordinate transformation algorithm is used to solve the constant drift of signals collected; secondly, a low-pass filter is designed to isolate gravity from signals real-timely via limited computing resources; thirdly, an embedded evaluation system is developed according to the calculation procedure specified by criterion ISO 2631-1997. Meanwhile, the model proposed is tested in a practical running environment, the vibration data in whole travel are recorded and analyzed offline. The results show that comfort degree of vibration obtained from the experimental system is identical with the truth, and this mode is proved to be effective.

  15. Theory of vibration protection

    CERN Document Server

    Karnovsky, Igor A

    2016-01-01

    This text is an advancement of the theory of vibration protection of mechanical systems with lumped and distributed parameters. The book offers various concepts and methods of solving vibration protection problems, discusses the advantages and disadvantages of different methods, and the fields of their effective applications. Fundamental approaches of vibration protection, which are considered in this book, are the passive, parametric and optimal active vibration protection. The passive vibration protection is based on vibration isolation, vibration damping and dynamic absorbers. Parametric vibration protection theory is based on the Shchipanov-Luzin invariance principle. Optimal active vibration protection theory is based on the Pontryagin principle and the Krein moment method. The book also contains special topics such as suppression of vibrations at the source of their occurrence and the harmful influence of vibrations on humans. Numerous examples, which illustrate the theoretical ideas of each chapter, ar...

  16. Model Predictive Vibration Control Efficient Constrained MPC Vibration Control for Lightly Damped Mechanical Structures

    CERN Document Server

    Takács, Gergely

    2012-01-01

    Real-time model predictive controller (MPC) implementation in active vibration control (AVC) is often rendered difficult by fast sampling speeds and extensive actuator-deformation asymmetry. If the control of lightly damped mechanical structures is assumed, the region of attraction containing the set of allowable initial conditions requires a large prediction horizon, making the already computationally demanding on-line process even more complex. Model Predictive Vibration Control provides insight into the predictive control of lightly damped vibrating structures by exploring computationally efficient algorithms which are capable of low frequency vibration control with guaranteed stability and constraint feasibility. In addition to a theoretical primer on active vibration damping and model predictive control, Model Predictive Vibration Control provides a guide through the necessary steps in understanding the founding ideas of predictive control applied in AVC such as: ·         the implementation of ...

  17. Improving alarm performance in the medical intensive care unit using delays and clinical context.

    Science.gov (United States)

    Görges, Matthias; Markewitz, Boaz A; Westenskow, Dwayne R

    2009-05-01

    In an intensive care unit, alarms are used to call attention to a patient, to alert a change in the patient's physiology, or to warn of a failure in a medical device; however, up to 94% of the alarms are false. Our purpose in this study was to identify a means of reducing the number of false alarms. An observer recorded time-stamped information of alarms and the presence of health care team members in the patient room; each alarm response was classified as effective (action taken within 5 min), ineffective (no response to the alarm), and ignored (alarm consciously ignored or actively silenced). During the 200-h study period, 1271 separate entries by an individual to the room being observed were recorded, 1214 alarms occurred and 2344 tasks were performed. On average, alarms occurred 6.07 times per hour and were active for 3.28 min per hour; 23% were effective, 36% were ineffective, and 41% were ignored. The median alarm duration was 17 s. A 14-s delay before alarm presentation would remove 50% of the ignored and ineffective alarms, and a 19-s delay would remove 67%. Suctioning, washing, repositioning, and oral care caused 152 ignored or ineffective ventilator alarms. Introducing a 19-s alarm delay and automatically detecting suctioning, repositioning, oral care, and washing could reduce the number of ineffective and ignored alarms from 934 to 274. More reliable alarms could elicit more timely response, reduce workload, reduce noise pollution, and potentially improve patient safety.

  18. Auditory backup alarms: distance-at-first-detection via in-situ experimentation on alarm design and hearing protection effects.

    Science.gov (United States)

    Alali, Khaled; Casali, John G

    2012-01-01

    The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them

  19. Alarm reduction with correlation analysis; Larmsanering genom korrelationsanalys

    Energy Technology Data Exchange (ETDEWEB)

    Bergquist, Tord; Ahnlund, Jonas; Johansson, Bjoern; Gaardman, Lennart; Raaberg, Martin [Lund Univ. (Sweden). Dept. of Information Technology

    2004-09-01

    This project's main interest is to improve the overall alarm situation in the control rooms. By doing so, the operators working environment is less overstrained, which simplifies the decision-making. According to a study of the British refinery industry, the operators make wrong decisions in four times out of ten due to badly tuned alarm systems, with heavy expenses as a result. Furthermore, a more efficiently alarm handling is estimated to decrease the production loss with between three and eight percent. This sounds, according to Swedish standards, maybe a bit extreme, but there is no doubt about the benefits of having a well-tuned alarm system. This project can be seen as an extension of 'General Methods for Alarm Reduction' (VARMEFORSK--835), where the process improvements were the result of suggestions tailored for every signal. Here, instead causal dependences in the process are examined. A method for this, specially designed to fit process signals, has been developed. It is called MLPC (Multiple Local Property Correlation) and could be seen as an unprejudiced way of increase the information value in the process. There are a number of ways to make use of the additional process understanding a correlation analysis provides. In the report some are mentioned, foremost aiming to improve the alarm situation for operators. Signals from two heating plants have been analyzed with MLPC. In simulations, with the use of the result from these analyses as a base, a large number of alarms have been successfully suppressed. The results have been studied by personal with process knowledge, and they are very positive to the use of MLPC and they express many benefits by the clarification of process relations. It was established in 'General Methods for Alarm Reduction' that low pass filter are superior to mean value filter and time delay when trying to suppress alarms. As a result, a module for signal processing has been developed. The main purpose is

  20. Quantitative trait loci influencing honeybee alarm pheromone levels.

    Science.gov (United States)

    Hunt, G J; Collins, A M; Rivera, R; Page, R E; Guzmán-Novoa, E

    1999-01-01

    Quantitative trait loci (QTL) mapping procedures were used to identify loci that influence the levels of alarm pheromones found in the stinging apparatus of worker honeybees. An F1 queen was produced from a cross between a queen of European origin and a drone descended from an African subspecies. Haploid drones from the hybrid queen were individually backcrossed to European queens to produce 172 colonies. Samples of stings were taken from backcross workers of these colonies. Alarm pheromone levels were determined by gas chromatography. RAPD markers were scored from the haploid drone fathers of these colonies. The multiple-QTL model (MQM) of MapQTL was used to identify QTLs that influence the levels of four alarm pheromone components. Seven independent, potential QTLs were identified with LOD scores greater than two, and one at LOD 1.88. We identified one QTL for n-decyl acetate, three for n-octanol, four for isopentyl acetate, and one for hexyl acetate. One region of linkage group XI shows a strong influence on body size and the levels of three alarm pheromone components. This locus explained 40% of the variance for the amount of n-decyl acetate (LOD 6.57). In general, the QTLs influencing alarm pheromone levels were independent of previously identified loci that influenced the stinging behavior of these colonies. The only exception was a potential locus influencing levels of n-octanol, which was inversely correlated with stinging behavior.

  1. FAULT DIAGNOSIS WITH MULTI-STATE ALARMS IN A NUCLEAR POWER CONTROL SIMULATOR

    Energy Technology Data Exchange (ETDEWEB)

    Austin Ragsdale; Roger Lew; Brian P. Dyre; Ronald L. Boring

    2012-10-01

    This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effect of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. We used sensitivity and criterion based on Signal Detection Theory to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed better and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.

  2. Reducing SCADA System Nuisance Alarms in the Water Industry in Northern Ireland.

    Science.gov (United States)

    O'Donoghue, Nigel; Phillips, Debra H; Nicell, Ciaran

    2015-08-01

    The advancement of telemetry control for the water industry has increased the difficulty of managing large volumes of nuisance alarms (i.e., alarms that do not require a response). The aim of this study was to identify and reduce the number of nuisance alarms that occur for Northern Ireland (NI) Water by carrying out alarm duration analysis to determine the appropriate length of persistence (an advanced alarm management tool) that could be applied. All data were extracted from TelemWeb (NI Water's telemetry monitoring system) and analyzed in Excel. Over a 6-week period, an average of 40 000 alarms occurred per week. The alarm duration analysis, which has never been implemented before by NI Water, found that an average of 57% of NI Water alarms had a duration of <5 minutes. Applying 5-minute persistence, therefore, could prevent an average 26 816 nuisance alarms per week. Most of these alarms were from wastewater assets.

  3. O treinamento de força com e sem o uso da plataforma vibratória é capaz de modular a variabilidade da frequência cardíaca em repouso? Strength training with and without a vibration platform is capable to modulate heart rate variability?

    Directory of Open Access Journals (Sweden)

    Rodrigo Poles Urso

    2012-09-01

    Full Text Available Esse trabalho comparou a variabilidade da frequência cardíaca (VFC de repouso antes e após 10 semanas de treinamento de força de grupos que usaram e não usaram a plataforma vibratória. Dezessete homens saudáveis foram divididos nos grupos treinamento de força convencional (TF ou treinamento de força sobre a plataforma vibratória a frequência de 30 Hz (TF+V30. As mensurações do desempenho de força dinâmica máxima (1-RM no exercício meio agachamento e da VFC de repouso foram feitas antes e após o programa de treinamento. Ambos os grupos tiveram aumento significante da força no período pós (de 15,1% no grupo TF e de 16,4% no grupo TF+V30, no entanto esse aumento se alterou na mesma magnitude para os dois grupos, não havendo diferença entre eles no desempenho de 1-RM nos períodos pré e pós-treinamento. Não foi observada diferença nas comparações entre os grupos e nas situações pré e pós-treinamento nas análises da VFC de repouso, no entanto a magnitude do effect size foi moderada (ES = 0,50-0,80 para algumas variáveis (intervalo R-R, desvio-padrão da média de todos os intervalos R-R - SDNN, raiz quadrada da média dos quadrados das diferenças entre os intervalos R-R sucessivos - RMSSD, componente de baixa frequência ajustada por meio de logarítmico - InLF e componente de alta frequência ajustada por meio de logarítmico - InHF no grupo TF+V30 após o período de treinamento. Conclui-se que 10 semanas de treinamento de força com e sem a presença da vibração proporcionou aumento semelhante no desempenho de 1-RM em ambos os grupos e, embora o estímulo adicional da vibração tenha dado indícios de maior atividade vagal analisado por meio do ES, nenhum dos grupos apresentou alteração significante da VFC.The current research compared resting heart rate variability (VFC before and after 10 weeks of strength training in groups that used and did not use a vibration platform. Seventeen healthy men were

  4. Anthropogenic noise alters dwarf mongoose responses to heterospecific alarm calls.

    Science.gov (United States)

    Morris-Drake, Amy; Bracken, Anna M; Kern, Julie M; Radford, Andrew N

    2017-04-01

    Anthropogenic noise is an evolutionarily novel and widespread pollutant in both terrestrial and aquatic habitats. Despite increasing evidence that the additional noise generated by human activities can affect vocal communication, the majority of research has focused on the use of conspecific acoustic information, especially sexual signals. Many animals are known to eavesdrop on the alarm calls produced by other species, enhancing their likelihood of avoiding predation, but how this use of heterospecific information is affected by anthropogenic noise has received little empirical attention. Here, we use two field-based playback experiments on a habituated wild population of dwarf mongooses (Helogale parvula) to determine how anthropogenic noise influences the response of foragers to heterospecific alarm calls. We begin by demonstrating that dwarf mongooses respond appropriately to the alarm calls of sympatric chacma baboons (Papio ursinus) and tree squirrels (Paraxerus cepapi); fleeing only to the latter. We then show that mongoose foragers are less likely to exhibit this flee response to tree squirrel alarm calls during road-noise playback compared to ambient-sound playback. One explanation for the change in response is that noise-induced distraction or stress result in maladaptive behaviour. However, further analysis revealed that road-noise playback results in increased vigilance and that mongooses showing the greatest vigilance increase are those that do not subsequently exhibit a flee response to the alarm call. These individuals may therefore be acting appropriately: if the greater gathering of personal information indicates the absence of an actual predator despite an alarm call, the need to undertake costly fleeing behaviour can be avoided. Either way, our study indicates the potential for anthropogenic noise to interfere with the use of acoustic information from other species, and suggests the importance of considering how heterospecific networks are

  5. Benefits of Spacecraft Level Vibration Testing

    Science.gov (United States)

    Gordon, Scott; Kern, Dennis L.

    2015-01-01

    NASA-HDBK-7008 Spacecraft Level Dynamic Environments Testing discusses the approaches, benefits, dangers, and recommended practices for spacecraft level dynamic environments testing, including vibration testing. This paper discusses in additional detail the benefits and actual experiences of vibration testing spacecraft for NASA Goddard Space Flight Center (GSFC) and Jet Propulsion Laboratory (JPL) flight projects. JPL and GSFC have both similarities and differences in their spacecraft level vibration test approach: JPL uses a random vibration input and a frequency range usually starting at 5 Hz and extending to as high as 250 Hz. GSFC uses a sine sweep vibration input and a frequency range usually starting at 5 Hz and extending only to the limits of the coupled loads analysis (typically 50 to 60 Hz). However, both JPL and GSFC use force limiting to realistically notch spacecraft resonances and response (acceleration) limiting as necessary to protect spacecraft structure and hardware from exceeding design strength capabilities. Despite GSFC and JPL differences in spacecraft level vibration test approaches, both have uncovered a significant number of spacecraft design and workmanship anomalies in vibration tests. This paper will give an overview of JPL and GSFC spacecraft vibration testing approaches and provide a detailed description of spacecraft anomalies revealed.

  6. No more moody mornings : Alarm clock anticipates sleepers' emotions

    NARCIS (Netherlands)

    Wensveen, S.; Overbeeke, K.; Van Kasteren, J.

    2002-01-01

    More eloquent alternatives to the harsh tones of the oldfashioned alarm-clock bells abound, including a newsreaders voice summing up last nights disasters, or a tape of your favourite early morning music. Still, getting out of bed has its difficult moments. All this could well change in the near

  7. Context‐dependent chemical communication: Alarm pheromones of thrips larvae

    NARCIS (Netherlands)

    de Bruijn, P.J.A.

    2015-01-01

    Thrips have several advantages that make them particularly suitable for the study of the evolution of alarm signalling. When in danger, thrips larvae defend themselves by the excretion of ‘anal droplets’: a predator touched by such a droplet interrupts the attack and switches to cleaning. These

  8. SeaQuest/E906 Shift Alarm System

    Science.gov (United States)

    Kitts, Noah

    2014-09-01

    SeaQuest, Fermilab E906, is a fixed target experiment that measures the Drell-Yan cross-section ratio of proton-proton to proton-deuterium collisions in order to extract the sea anti-quark structure of the proton. SeaQuest will extend the measurements made by E866/NuSea with greater precision at higher Bjorken-x. The continuously running experiment is always being monitored. Those on shift must keep track of all of the detector readouts in order to make sure the experiment is running correctly. As an experiment that is still in its early stages of running, an alarm system for people on shift is being created to provide warnings, such as a plot showing a detector's performance is sufficiently different to need attention. This plan involves python scripts that track live data. When the data shows a problem within the experiment, a corresponding alarm ID is sent to the MySQL database which then sets off an alarm. These alarms, which will alert the person on shift through both an audible and visual response, are important for ensuring that issues do not go unnoticed, and to help make sure the experiment is recording good data.

  9. Development of a blood pressure alarm detector based on seven ...

    African Journals Online (AJOL)

    This paper introduces the development of a blood pressure alarm detector, meant to be incorporated into an electronic blood pressure tracking unit, from which it detects signals for the measured blood pressure (BP), that is, the systolic blood pressure (SBP) and diastolic blood pressure (DBP). It simultaneously displays the ...

  10. 24 CFR 3280.208 - Smoke alarm requirements.

    Science.gov (United States)

    2010-04-01

    ... of 177 candela, except that when the visible notification appliance is wall-mounted or suspended more than 24 inches below the ceiling, a minimum rating of 110 candela is permitted. (3) A visible... candela. (f) Testing and maintenance. (1) Each required smoke alarm installed at the factory must be...

  11. Alarm management in TRANSPETRO National Oil Control Center

    Energy Technology Data Exchange (ETDEWEB)

    Amado, Helio; Costa, Luciano [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    For sure Alarm Management is not a new issue. EEMUA 191 has been around since 1999 and everyone has received visits from consultants in this area. Besides this regulators have requested that operators have a policy for it. However there are few papers showing actual pipeline operator experience in alarm management. In this paper we present the work developed in TRANSPETRO National Oil Control Center since 2006, where we operate 5509 km of crude oil and refined products pipelines. Since the beginning of the centralized operation in 2002, alarm management has been a concern but a systematic approach has been taken since 2006. Initially we will make a brief revision of the literature and show trends for regulations. Then we will show the tools and the approach we have taken. Finally, the further developments we see. The point that we want to discuss is that, it has been very difficult to implement the system in a linear way and we believe that companies that have huge legacy systems, the same probably will occur. Putting in simple words, our main conclusion is: Implementing an Alarm Management policy produces good results however probably sometimes is better not to follow strictly the traditional steps. (author)

  12. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Science.gov (United States)

    2010-10-01

    ..., AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Pollution Prevention Equipment § 162... the ppm display. Calibrating the bilge alarm must not be necessary once installed on board the vessel... each change in oil content of the mixture it is measuring within 5 seconds after the change occurs. (f...

  13. Solar Energetic Particle Forecasting Algorithms and Associated False Alarms

    Science.gov (United States)

    Swalwell, B.; Dalla, S.; Walsh, R. W.

    2017-11-01

    Solar energetic particle (SEP) events are known to occur following solar flares and coronal mass ejections (CMEs). However, some high-energy solar events do not result in SEPs being detected at Earth, and it is these types of event which may be termed "false alarms". We define two simple SEP forecasting algorithms based upon the occurrence of a magnetically well-connected CME with a speed in excess of 1500 km s^{-1} (a "fast" CME) or a well-connected X-class flare and analyse them with respect to historical datasets. We compare the parameters of those solar events which produced an enhancement of {>} 40 MeV protons at Earth (an "SEP event") and the parameters of false alarms. We find that an SEP forecasting algorithm based solely upon the occurrence of a well-connected fast CME produces fewer false alarms (28.8%) than an algorithm which is based solely upon a well-connected X-class flare (50.6%). Both algorithms fail to forecast a relatively high percentage of SEP events (53.2% and 50.6%, respectively). Our analysis of the historical datasets shows that false-alarm X-class flares were either not associated with any CME, or were associated with a CME slower than 500 km s^{-1}; false-alarm fast CMEs tended to be associated with flare classes lower than M3. A better approach to forecasting would be an algorithm which takes as its base the occurrence of both CMEs and flares. We define a new forecasting algorithm which uses a combination of CME and flare parameters, and we show that the false-alarm ratio is similar to that for the algorithm based upon fast CMEs (29.6%), but the percentage of SEP events not forecast is reduced to 32.4%. Lists of the solar events which gave rise to {>} 40 MeV protons and the false alarms have been derived and are made available to aid further study.

  14. Vibration and stress analysis of soft-bonded shuttle insulation tiles. Modal analysis with compact widely space stringers

    Science.gov (United States)

    Ojalvo, I. U.; Austin, F.; Levy, A.

    1974-01-01

    An efficient iterative procedure is described for the vibration and modal stress analysis of reusable surface insulation (RSI) of multi-tiled space shuttle panels. The method, which is quite general, is rapidly convergent and highly useful for this application. A user-oriented computer program based upon this procedure and titled RESIST (REusable Surface Insulation Stresses) has been prepared for the analysis of compact, widely spaced, stringer-stiffened panels. RESIST, which uses finite element methods, obtains three dimensional tile stresses in the isolator, arrestor (if any) and RSI materials. Two dimensional stresses are obtained in the tile coating and the stringer-stiffened primary structure plate. A special feature of the program is that all the usual detailed finite element grid data is generated internally from a minimum of input data. The program can accommodate tile idealizations with up to 850 nodes (2550 degrees-of-freedom) and primary structure idealizations with a maximum of 10,000 degrees-of-freedom. The primary structure vibration capability is achieved through the development of a new rapid eigenvalue program named ALARM (Automatic LArge Reduction of Matrices to tridiagonal form).

  15. Sensor fusion for active vibration isolation in precision equipment

    NARCIS (Netherlands)

    Tjepkema, D.; van Dijk, Johannes; Soemers, Herman

    2012-01-01

    Sensor fusion is a promising control strategy to improve the performance of active vibration isolation systems that are used in precision equipment. Normally, those vibration isolation systems are only capable of realizing a low transmissibility. Additional objectives are to increase the damping

  16. Practical design of a nonlinear tuned vibration absorber

    DEFF Research Database (Denmark)

    Grappasonni, C.; Habib, G.; Detroux, T.

    2014-01-01

    The aim of the paper is to develop a new nonlinear tuned vibration absorber (NLTVA) capable of mitigating the vibrations of nonlinear systems which are known to exhibit frequency-energy-dependent oscillations. A nonlinear generalization of Den Hartog's equal-peak method is proposed to ensure equal...

  17. Tunable Passive Vibration Suppressor

    Science.gov (United States)

    Boechler, Nicholas (Inventor); Dillon, Robert Peter (Inventor); Daraio, Chiara (Inventor); Davis, Gregory L. (Inventor); Shapiro, Andrew A. (Inventor); Borgonia, John Paul C. (Inventor); Kahn, Daniel Louis (Inventor)

    2016-01-01

    An apparatus and method for vibration suppression using a granular particle chain. The granular particle chain is statically compressed and the end particles of the chain are attached to a payload and vibration source. The properties of the granular particles along with the amount of static compression are chosen to provide desired filtering of vibrations.

  18. Vibrations and Eigenvalues

    Indian Academy of Sciences (India)

    We make music by causing strings, membranes, or air columns to vibrate. Engineers design safe structures by control- ling vibrations. I will describe to you a very simple vibrating system and the mathematics needed to analyse it. The ideas were born in the work of Joseph-Louis Lagrange (1736–1813), and I begin by quot-.

  19. Smoke Alarms for People Who Are Deaf or Hard-of-Hearing

    Science.gov (United States)

    ... topic Toggle this sub-menu open or closed Smoke alarms Wildfire Emergency preparedness Fire and life safety ... Education Public Education By topic Expand sub-navigation Smoke alarms Expand sub-navigation Safety messages about smoke ...

  20. Potential Nematode Alarm Pheromone Induces Acute Avoidance in Caenorhabditis elegans.

    Science.gov (United States)

    Zhou, Ying; Loeza-Cabrera, Mario; Liu, Zheng; Aleman-Meza, Boanerges; Nguyen, Julie K; Jung, Sang-Kyu; Choi, Yuna; Shou, Qingyao; Butcher, Rebecca A; Zhong, Weiwei

    2017-07-01

    It is crucial for animal survival to detect dangers such as predators. A good indicator of dangers is injury of conspecifics. Here we show that fluids released from injured conspecifics invoke acute avoidance in both free-living and parasitic nematodes. Caenorhabditis elegans avoids extracts from closely related nematode species but not fruit fly larvae. The worm extracts have no impact on animal lifespan, suggesting that the worm extract may function as an alarm instead of inflicting physical harm. Avoidance of the worm extract requires the function of a cGMP signaling pathway that includes the cGMP-gated channel TAX-2/TAX-4 in the amphid sensory neurons ASI and ASK. Genetic evidence indicates that the avoidance behavior is modulated by the neurotransmitters GABA and serotonin, two common targets of anxiolytic drugs. Together, these data support a model that nematodes use a nematode-specific alarm pheromone to detect conspecific injury. Copyright © 2017 by the Genetics Society of America.

  1. Principal Components Analysis of Triaxial Vibration Data From Helicopter Transmissions

    Science.gov (United States)

    Tumer, Irem Y.; Huff, Edward M.

    2001-01-01

    Research on the nature of the vibration data collected from helicopter transmissions during flight experiments has led to several crucial observations believed to be responsible for the high rates of false alarms and missed detections in aircraft vibration monitoring systems. This work focuses on one such finding, namely, the need to consider additional sources of information about system vibrations. In this light, helicopter transmission vibration data, collected using triaxial accelerometers, were explored in three different directions, analyzed for content, and then combined using Principal Components Analysis (PCA) to analyze changes in directionality. In this paper, the PCA transformation is applied to 176 test conditions/data sets collected from an OH58C helicopter to derive the overall experiment-wide covariance matrix and its principal eigenvectors. The experiment-wide eigenvectors. are then projected onto the individual test conditions to evaluate changes and similarities in their directionality based on the various experimental factors. The paper will present the foundations of the proposed approach, addressing the question of whether experiment-wide eigenvectors accurately model the vibration modes in individual test conditions. The results will further determine the value of using directionality and triaxial accelerometers for vibration monitoring and anomaly detection.

  2. Propose an alternative method to generate alarm management KPI utilizing IMS in offshore platforms

    OpenAIRE

    Villoria Yepez, Carlos Rafael

    2013-01-01

    Weaknesses regarding alarm management practices have been recognized as partial causes of plant incidents with tragic results, for example the Texas City Oil Refinery explosion in 2005. Necessity in alarm regulation was recognized by industry bodies and norms were created (EEMUA 119, ANSI/ISA 18.2) in order to address this. These norms define a complete alarm management lifecycle, including the definition of an alarm performance monitoring process with the supervision of ala...

  3. Propose an alternative method to generate alarm management KPI utilizing IMS in offshore platforms

    OpenAIRE

    Villoria Yepez, Carlos Rafael

    2013-01-01

    Master's thesis in Offshore technology Weaknesses regarding alarm management practices have been recognized as partial causes of plant incidents with tragic results, for example the Texas City Oil Refinery explosion in 2005. Necessity in alarm regulation was recognized by industry bodies and norms were created (EEMUA 119, ANSI/ISA 18.2) in order to address this. These norms define a complete alarm management lifecycle, including the definition of an alarm performance moni...

  4. User image mismatch in anaesthesia alarms: a cognitive systems analysis.

    Science.gov (United States)

    Raymer, Karen E; Bergström, Johan

    2013-01-01

    In this study, principles of Cognitive Systems Engineering are used to better understand the human-machine interaction manifesting in the use of anaesthesia alarms. The hypothesis is that the design of the machine incorporates built-in assumptions of the user that are discrepant with the anaesthesiologist's self-assessment, creating 'user image mismatch'. Mismatch was interpreted by focusing on the 'user image' as described from the perspectives of both machine and user. The machine-embedded image was interpreted through document analysis. The user-described image was interpreted through user (anaesthesiologist) interviews. Finally, an analysis was conducted in which the machine-embedded and user-described images were contrasted to identify user image mismatch. It is concluded that analysing user image mismatch expands the focus of attention towards macro-elements in the interaction between man and machine. User image mismatch is interpreted to arise from complexity of algorithm design and incongruity between alarm design and tenets of anaesthesia practice. Cognitive system engineering principles are applied to enhance the understanding of the interaction between anaesthesiologist and alarm. The 'user image' is interpreted and contrasted from the perspectives of machine as well as the user. Apparent machine-user mismatch is explored pertaining to specific design features.

  5. Myocardial infarction false alarm: initial electrocardiogram and cardiac enzymes.

    Science.gov (United States)

    Gupta, Esha Das; Sakthiswary, Rajalingham

    2014-05-01

    The objectives of this study were to determine the incidence of a myocardial infarction "false alarm" and evaluate the efficacy of the initial electrocardiogram and cardiac enzymes in diagnosing myocardial infarction in Malaysia. We recruited patients who were admitted with suspected myocardial infarction from June to August 2008. The medical records of these patients were reviewed for the initial electrocardiogram, initial cardiac enzyme levels (creatinine kinase-MB and troponin T), and the final diagnosis upon discharge. The subjects were stratified into 2 groups: true myocardial infarction, and false alarm. 125 patients were enrolled in this study. Following admission and further evaluation, the diagnosis was revised from myocardial infarction to other medical conditions in 48 (38.4%) patients. The sensitivity and specificity of the initial ischemic electrocardiographic changes were 54.5% and 70.8%, respectively. Raised cardiac enzymes had a sensitivity of 44.3% and specificity of 95.8%. A significant proportion of patients in Malaysia are admitted with a false-alarm myocardial infarction. The efficacy of the electrocardiogram in diagnosing myocardial infarction in Malaysia was comparable to the findings of Western studies, but the cardiac enzymes had a much lower sensitivity.

  6. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  7. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm, must...

  8. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Instrumentation, alarms, and centralized stations. 62.25... Instrumentation, alarms, and centralized stations. (a) General. Minimum instrumentation and alarms required for specific types of automated vital systems are listed in Table 62.35-50. (b) Instrumentation Location. (1...

  9. Damage Detection by Laser Vibration Measurement

    Directory of Open Access Journals (Sweden)

    Elena Daniela Birdeanu

    2008-10-01

    Full Text Available The technique based on the vibration analysis by scanning laser Doppler vibrometer is one of the most promising, allowing to extract also small defect and to directly correlate it to local dynamic stiffness and structural integrity. In fact, the measurement capabilities of vibrometers, such as sensitivity, accuracy and reduced intrusively, allow having a very powerful instrument in diagnostic.

  10. Internal Temperature Control For Vibration Testers

    Science.gov (United States)

    Dean, Richard J.

    1996-01-01

    Vibration test fixtures with internal thermal-transfer capabilities developed. Made of aluminum for rapid thermal transfer. Small size gives rapid response to changing temperatures, with better thermal control. Setup quicker and internal ducting facilitates access to parts being tested. In addition, internal flows smaller, so less energy consumed in maintaining desired temperature settings.

  11. Vibration analysis of cryocoolers

    Science.gov (United States)

    Tomaru, Takayuki; Suzuki, Toshikazu; Haruyama, Tomiyoshi; Shintomi, Takakazu; Yamamoto, Akira; Koyama, Tomohiro; Li, Rui

    2004-05-01

    The vibrations of Gifford-McMahon (GM) and pulse-tube (PT) cryocoolers were measured and analyzed. The vibrations of the cold-stage and cold-head were measured separately to investigate their vibration mechanisms. The measurements were performed while maintaining the thermal conditions of the cryocoolers at a steady state. We found that the vibration of the cold-head for the 4 K PT cryocooler was two orders of magnitude smaller than that of the 4 K GM cryocooler. On the other hand, the vibration of the cold-stages for both cryocoolers was of the same order of magnitude. From a spectral analysis of the vibrations and a simulation, we concluded that the vibration of the cold-stage is caused by an elastic deformation of the pulse tubes (or cylinders) due to the pressure oscillation of the working gas.

  12. Vibration analysis of cryocoolers

    Energy Technology Data Exchange (ETDEWEB)

    Tomaru, Takayuki; Suzuki, Toshikazu; Haruyama, Tomiyoshi; Shintomi, Takakazu; Yamamoto, Akira [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki (Japan); Koyama, Tomohiro; Rui Li [Sumitomo Heavy Industries Ltd., Tokyo (Japan)

    2004-05-01

    The vibrations of Gifford-McMahon (GM) and pulse-tube (PT) cryocoolers were measured and analyzed. The vibrations of the cold-stage and cold-head were measured separately to investigate their vibration mechanisms. The measurements were performed while maintaining the thermal conditions of the cryocoolers at a steady state. We found that the vibration of the cold-head for the 4 K PT cryocooler was two orders of magnitude smaller than that of the 4 K GM cryocooler. On the other hand, the vibration of the cold-stages for both cryocoolers was of the same order of magnitude. From a spectral analysis of the vibrations and a simulation, we concluded that the vibration of the cold-stage is caused by an elastic deformation of the pulse tubes (or cylinders) due to the pressure oscillation of the working gas. (Author)

  13. Vibration of hydraulic machinery

    CERN Document Server

    Wu, Yulin; Liu, Shuhong; Dou, Hua-Shu; Qian, Zhongdong

    2013-01-01

    Vibration of Hydraulic Machinery deals with the vibration problem which has significant influence on the safety and reliable operation of hydraulic machinery. It provides new achievements and the latest developments in these areas, even in the basic areas of this subject. The present book covers the fundamentals of mechanical vibration and rotordynamics as well as their main numerical models and analysis methods for the vibration prediction. The mechanical and hydraulic excitations to the vibration are analyzed, and the pressure fluctuations induced by the unsteady turbulent flow is predicted in order to obtain the unsteady loads. This book also discusses the loads, constraint conditions and the elastic and damping characters of the mechanical system, the structure dynamic analysis, the rotor dynamic analysis and the system instability of hydraulic machines, including the illustration of monitoring system for the instability and the vibration in hydraulic units. All the problems are necessary for vibration pr...

  14. Masters Thesis- Criticality Alarm System Design Guide with Accompanying Alarm System Development for the Radioisotope Production Laboratory in Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Greenfield, Bryce A. [Univ. of New Mexico, Albuquerque, NM (United States)

    2009-12-01

    A detailed instructional manual was created to guide criticality safety engineers through the process of designing a criticality alarm system (CAS) for Department of Energy (DOE) hazard class 1 and 2 facilities. Regulatory and technical requirements were both addressed. A list of design tasks and technical subtasks are thoroughly analyzed to provide concise direction for how to complete the analysis. An example of the application of the design methodology, the Criticality Alarm System developed for the Radioisotope Production Laboratory (RPL) of Richland, Washington is also included. The analysis for RPL utilizes the Monte Carlo code MCNP5 for establishing detector coverage in the facility. Significant improvements to the existing CAS were made that increase the reliability, transparency, and coverage of the system.

  15. Development of methods and means to improve a performance of microprocessor shock sensors for car alarms

    Directory of Open Access Journals (Sweden)

    S. A. Vasyukov

    2014-01-01

    -line adjusting characteristic.The developed shock sensor is implemented as stock-produced items included in the car alarm systems of the trademark “Excellent” (made by JSC Magic Ring Ltd.. Operating experience (about 40 thousand pieces realized now allows a proper adjustment of sensors to be possible on cars with any body type. A sufficient level of the sensor sensitivity proves it. The reliability of sensors is confirmed by failures statistics in use (0,08%. Failures are, usually, caused by the SE coil wire break in a soldering point of the coil leads to the printed circuit. However a number of shortcomings are also revealed.Experimental data processing of a test batch of sensors has shown that existing SE of electromagnetic type have the frequency of free vibrations f 805Hz and a decay constant of transient under shock  0,2s. At these parameters a SE pass-band makes only f 1,5Hz, and the sensor responses only to the shock front, rather than to the secondary vibrations of a body. It is an essential drawback of the narrow-band sensors.The experiments conducted on test batch of sensors (10 samples have shown essentially different sensitivities of sensors under shock in the direction of the sensitivity axis and perpendicular to it. This difference reaches 4-6 gradations of sensitivity. It means that when mounting a sensor on the particular car the orientation of sensitivity axis of the sensor will be of crucial importance that is also a shortcoming.It is shown that overcoming the specified drawbacks is hardly because of the improvement of sensitive elements suspension of electromagnetic sensors. Three-axial accelerometers implemented using MEMS technologies seem to be the most perspective application here.

  16. Rights, goals, and capabilities

    NARCIS (Netherlands)

    van Hees, M.

    2013-01-01

    This article analyses the relationship between rights and capabilities in order to get a better grasp of the kind of consequentialism that the capability theory represents. Capability rights have been defined as rights that have a capability as their object (rights to capabilities). Such a

  17. Rights, goals, and capabilities

    NARCIS (Netherlands)

    van Hees, M.V.B.P.M

    This article analyses the relationship between rights and capabilities in order to get a better grasp of the kind of consequentialism that the capability theory represents. Capability rights have been defined as rights that have a capability as their object (rights to capabilities). Such a

  18. Automatically Identifying and Predicting Unplanned Wind Turbine Stoppages Using SCADA and Alarms System Data: Case Study and Results

    Science.gov (United States)

    Leahy, Kevin; Gallagher, Colm; Bruton, Ken; O’Donovan, Peter; O’Sullivan, Dominic T. J.

    2017-11-01

    Using 10-minute wind turbine SCADA data for fault prediction offers an attractive way of gaining additional prognostic capabilities without needing to invest in extra hardware. To use these data-driven methods effectively, the historical SCADA data must be labelled with the periods when the turbine was in faulty operation as well the sub-system the fault was attributed to. Manually identifying faults using maintenance logs can be effective, but is also highly time consuming and tedious due to the disparate nature of these logs across manufacturers, operators and even individual maintenance events. Turbine alarm systems can help to identify these periods, but the sheer volume of alarms and false positives generated makes analysing them on an individual basis ineffective. In this work, we present a new method for automatically identifying historical stoppages on the turbine using SCADA and alarms data. Each stoppage is associated with either a fault in one of the turbine’s sub-systems, a routine maintenance activity, a grid-related event or a number of other categories. This is then checked against maintenance logs for accuracy and the labelled data fed into a classifier for predicting when these stoppages will occur. Results show that the automated labelling process correctly identifies each type of stoppage, and can be effectively used for SCADA-based prediction of turbine faults.

  19. Leak detection capability in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Azer, N.; Barber, D.H.; Boucher, P.J. [and others

    1997-04-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.

  20. The design of infrared alarm system based on ZigBee technology

    Science.gov (United States)

    Yin, Qiang; Yu, Haiyang; Shao, Xingling; Wang, Zhengyan; Yang, Wei; Zhang, Wendong

    2011-06-01

    In view of the existing shortcomings of the existing infrared system,such as complicated structure, high transmitting power, expensive cost and etc. A infrared alarm system based on ZigBee technology was presented in this paper. The system consists of owner-alarm, the monitoring room in the housing estate and network router. Through the alarm information detected by infrared sensors, it starts the way of local sound alarm or networking alarm. The results of test demonstrate that the system is convenient for use and reliable for performance.

  1. Human factors engineering guidance for the review of advanced alarm systems

    Energy Technology Data Exchange (ETDEWEB)

    O`Hara, J.M.; Brown, W.S.; Higgins, J.C.; Stubler, W.F. [Brookhaven National Lab., Upton, NY (United States)

    1994-09-01

    This report provides guidance to support the review of the human factors aspects of advanced alarm system designs in nuclear power plants. The report is organized into three major sections. The first section describes the methodology and criteria that were used to develop the design review guidelines. Also included is a description of the scope, organization, and format of the guidelines. The second section provides a systematic review procedure in which important characteristics of the alarm system are identified, described, and evaluated. The third section provides the detailed review guidelines. The review guidelines are organized according to important characteristics of the alarm system including: alarm definition; alarm processing and reduction; alarm prioritization and availability; display; control; automated; dynamic, and modifiable characteristics; reliability, test, maintenance, and failure indication; alarm response procedures; and control-display integration and layout.

  2. Mobile Test Capabilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrical Power Mobile Test capabilities are utilized to conduct electrical power quality testing on aircraft and helicopters. This capability allows that the...

  3. Customized DSP-based vibration measurement for wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    LaWhite, N.E.; Cohn, K.E. [Second Wind Inc., Somerville, MA (United States)

    1996-12-31

    As part of its Advanced Distributed Monitoring System (ADMS) project funded by NREL, Second Wind Inc. is developing a new vibration measurement system for use with wind turbines. The system uses low-cost accelerometers originally designed for automobile airbag crash-detection coupled with new software executed on a Digital Signal Processor (DSP) device. The system is envisioned as a means to monitor the mechanical {open_quotes}health{close_quotes} of the wind turbine over its lifetime. In addition the system holds promise as a customized emergency vibration detector. The two goals are very different and it is expected that different software programs will be executed for each function. While a fast Fourier transform (FFT) signature under given operating conditions can yield much information regarding turbine condition, the sampling period and processing requirements make it inappropriate for emergency condition monitoring. This paper briefly reviews the development of prototype DSP and accelerometer hardware. More importantly, it reviews our work to design prototype vibration alarm filters. Two-axis accelerometer test data from the experimental FloWind vertical axis wind turbine is analyzed and used as a development guide. Two levels of signal processing are considered. The first uses narrow band pre-processing filters at key fundamental frequencies such as the 1P, 2P and 3P. The total vibration energy in each frequency band is calculated and evaluated as a possible alarm trigger. In the second level of signal processing, the total vibration energy in each frequency band is further decomposed using the two-axis directional information. Directional statistics are calculated to differentiate between linear translations and circular translations. After analyzing the acceleration statistics for normal and unusual operating conditions, the acceleration processing system described could be used in automatic early detection of fault conditions. 9 figs.

  4. An experimental investigation of the effects of alarm processing and display on operator performance

    Energy Technology Data Exchange (ETDEWEB)

    O`Hara, J.; Brown, W. [Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology; Hallbert, B.; Skraaning, G. [Halden Reactor Project (Norway); Wachtel, J.; Persensky, J. [Nuclear Regulatory Commission, Washington, DC (United States). Office of Nuclear Regulatory Research

    1998-03-01

    This paper describes a research program sponsored by the US Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. As part of this program, guidance has been developed based on a broad base of technical and research literature. In the course of guidance development, aspects of alarm system design for which the technical basis was insufficient to support complete guidance development were identified. The primary purpose of the research reported in this paper was to evaluate the effects of three of these alarm system design characteristics on operator performance in order to contribute to the understanding of potential safety issues and to provide data to support the development of design review guidance in these areas. Three alarm system design characteristics studied were (1) alarm processing (degree of alarm reduction), (2) alarm availability (dynamic prioritization and suppression), and (3) alarm display (a dedicated tile format, a mixed tile and message list format, and a format in which alarm information is integrated into the process displays). A secondary purpose was to provide confirmatory evidence of selected alarm system guidance developed in an earlier phase of the project. The alarm characteristics were combined into eight separate experimental conditions. Six, two-person crews of professional nuclear power plant operators participated in the study. Following training, each crew completed 16 test trials which consisted of two trials in each of the eight experimental conditions (one with a low-complexity scenario and one with a high-complexity scenario). Measures of process performance, operator task performance, situation awareness, and workload were obtained. In addition, operator opinions and evaluations of the alarm processing and display conditions were collected. No deficient

  5. The ecology and evolution of avian alarm call signaling systems

    Science.gov (United States)

    Billings, Alexis Chandon

    Communication is often set up as a simple dyadic exchange between one sender and one receiver. However, in reality, signaling systems have evolved and are used with many forms and types of information bombarding multiple senders, who in turn send multiple signals of different modalities, through various environmental spaces, finally reaching multiple receivers. In order to understand both the ecology and evolution of a signaling system, we must examine all the facets of the signaling system. My dissertation focused on the alarm call signaling system in birds. Alarm calls are acoustic signals given in response to danger or predators. My first two chapters examine how information about predators alters alarm calls. In chapter one I found that chickadees make distinctions between predators of different hunting strategies and appear to encode information about predators differently if they are heard instead of seen. In my second chapter, I test these findings more robustly in a non-model bird, the Steller's jay. I again found that predator species matters, but that how Steller's jays respond if they saw or heard the predator depends on the predator species. In my third chapter, I tested how habitat has influenced the evolution of mobbing call acoustic structure. I found that habitat is not a major contributor to the variation in acoustic structure seen across species and that other selective pressures such as body size may be more important. In my fourth chapter I present a new framework to understand the evolution of multimodal communication across species. I identify a unique constraint, the need for overlapping sensory systems, thresholds and cognitive abilities between sender and receiver in order for different forms of interspecific communication to evolve. Taken together, these chapters attempt to understand a signaling system from both an ecological and evolutionary perspective by examining each piece of the communication scheme.

  6. Detecting outliers in multivariate data while controlling false alarm rate

    Directory of Open Access Journals (Sweden)

    André Achim

    2012-06-01

    Full Text Available Outlier identification often implies inspecting each z-transformed variable and adding a Mahalanobis D^2. Multiple outliers may mask each other by increasing variance estimates. Caroni and Prescott (1992 proposed a multivariate extension of Rosner’s (1983 technique to circumvent masking, taking sample size into account to keep the false alarm risk below, say, alpha = .05. Simulations studies here compare the single multivariate approach to "multiple-univariate plus multivariate" tests, each at a Bonferroni corrected alpha level, in terms of power at detecting outliers. Results suggest the former is better only up to about 12 variables. Macros in an Excel spreadsheet implement these techniques.

  7. Environmental toxins: alarming impacts of pesticides on male fertility.

    Science.gov (United States)

    Sengupta, Pallav; Banerjee, Rajdeb

    2014-10-01

    This review comprehensively summarizes the effects of more than 15 mostly used pesticides on male reproductive physiology, as recent experimental and epidemiological research have indicated their alarming impact on overall human health. Mechanisms have described that pesticide exposure damages spermatozoa, alter Sertoli or Leydig cell function, both in vitro and in vivo and thus affects semen quality. But, the literature suggests a need for more intricate research in those pesticides that are defined as mutagens or carcinogens and directly affect the hypothalamic-pituitary-gonadal axis. This literature review also proposes specific solutions to overcome these health effects. © The Author(s) 2013.

  8. Low Power Wireless Smoke Alarm System in Home Fires

    Directory of Open Access Journals (Sweden)

    Juan Aponte Luis

    2015-08-01

    Full Text Available A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects.

  9. GESTION D'ALARME À BASE DE CHRONIQUE

    OpenAIRE

    Vásquez Capacho, John William

    2017-01-01

    Thèse en cotutelle avec l'Universidad de los Andes, Colombie; National audience; This thesis work was carried out in the framework of a co-tutelle between INSA, Toulouse, and the University of the Andes, Colombia, with financial support of Colciencias. This work is motivated by the need of the industry to detect abnormal situations in the plant startup and shutdown stages. Industrial plants involve integrated management of all the events that may cause accidents and translate into alarms. Pro...

  10. The heuristics of nurse responsiveness to critical patient monitor and ventilator alarms in a private room neonatal intensive care unit.

    Science.gov (United States)

    Joshi, Rohan; Mortel, Heidi van de; Feijs, Loe; Andriessen, Peter; Pul, Carola van

    2017-01-01

    Alarm fatigue is a well-recognized patient safety concern in intensive care settings. Decreased nurse responsiveness and slow response times to alarms are the potentially dangerous consequences of alarm fatigue. The aim of this study was to determine the factors that modulate nurse responsiveness to critical patient monitor and ventilator alarms in the context of a private room neonatal intensive care setting. The study design comprised of both a questionnaire and video monitoring of nurse-responsiveness to critical alarms. The Likert scale questionnaire, comprising of 50 questions across thematic clusters (critical alarms, yellow alarms, perception, design, nursing action, and context) was administered to 56 nurses (90% response rate). Nearly 6000 critical alarms were recorded from 10 infants in approximately 2400 hours of video monitoring. Logistic regression was used to identify patient and alarm-level factors that modulate nurse-responsiveness to critical alarms, with a response being defined as a nurse entering the patient's room within the 90s of the alarm being generated. Based on the questionnaire, the majority of nurses found critical alarms to be clinically relevant even though the alarms did not always mandate clinical action. Based on video observations, for a median of 34% (IQR, 20-52) of critical alarms, the nurse was already present in the room. For the remaining alarms, the response rate within 90s was 26%. The median response time was 55s (IQR, 37-70s). Desaturation alarms were the most prevalent and accounted for more than 50% of all alarms. The odds of responding to bradycardia alarms, compared to desaturation alarms, were 1.47 (95% CI = 1.21-1.78; heuristics in determining whether or not to respond to the alarm. Amongst other factors, the category and duration of critical alarms along with the clinical status of the patient determine nurse-responsiveness to alarms.

  11. Alarm Pheromone Composition and Behavioral Activity in Fungus-Growing Ants.

    Science.gov (United States)

    Norman, Victoria C; Butterfield, Thomas; Drijfhout, Falko; Tasman, Kiah; Hughes, William O H

    2017-03-01

    Chemical communication is a dominant method of communication throughout the animal kingdom and can be especially important in group-living animals in which communicating threats, either from predation or other dangers, can have large impacts on group survival. Social insects, in particular, have evolved a number of pheromonal compounds specifically to signal alarm. There is predicted to be little selection for interspecific variation in alarm cues because individuals may benefit from recognizing interspecific as well as conspecific cues and, consequently, alarm cues are not normally thought to be used for species or nestmate recognition. Here, we examine the composition of the alarm pheromones of seven species of fungus-growing ants (Attini), including both basal and derived species and examine the behavioral responses to alarm pheromone of Acromyrmex leaf-cutting ants, the sister genus to the highly studied Atta leaf-cutting ants. We find surprisingly high interspecific variation in alarm pheromone composition across the attine phylogeny. Interestingly, the active component of the alarm pheromone was different between the two leaf-cutting ant genera. Furthermore, in contrast to previous studies on Atta, we found no differences among morphological castes in their responses to alarm pheromone in Acromyrmex but we did find differences in responses among putative age classes. The results suggest that the evolution of alarm communication and signaling within social insect clades can be unexpectedly complex and that further work is warranted to understand whether the evolution of different alarm pheromone compounds is adaptive.

  12. Development and experimental evaluation of an alarm concept for an integrated surgical workstation.

    Science.gov (United States)

    Zeißig, Eva-Maria; Janß, Armin; Dell'Anna-Pudlik, Jasmin; Ziefle, Martina; Radermacher, Klaus

    2016-04-01

    Alarm conditions of the technical equipment in operating rooms represent a prevalent cause for interruptions of surgeons and scrub nurses, resulting in an increase of workload and potential reduction of patient safety. In this work, an alarm concept for an integrated operating room system based on open communication standards is developed and tested. In a laboratory experiment, the reactions of surgeons were analysed, comparing the displaying of alarms on an integrated workstation and on single devices: disruptive effects of alarm handling on primary task (ratings of perceived distraction, resumption lag, deterioration of speed, accuracy, and prospective memory), efficiency and effectiveness of identification of alarms, as well as perceived workload were included. The identification of the alarm cause is significantly more efficient and effective with the integrated alarm concept. Moreover, a slightly lower deterioration of performance of the primary task due to the interruption of alarm handling was observed. Displaying alarms on an integrated workstation supports alarm handling and consequently reduces disruptive effects on the primary task. The findings show that even small changes can reduce workload in a complex work environment like the operating room, resulting in improved patient safety.

  13. Flights of fear: a mechanical wing whistle sounds the alarm in a flocking bird.

    Science.gov (United States)

    Hingee, Mae; Magrath, Robert D

    2009-12-07

    Animals often form groups to increase collective vigilance and allow early detection of predators, but this benefit of sociality relies on rapid transfer of information. Among birds, alarm calls are not present in all species, while other proposed mechanisms of information transfer are inefficient. We tested whether wing sounds can encode reliable information on danger. Individuals taking off in alarm fly more quickly or ascend more steeply, so may produce different sounds in alarmed than in routine flight, which then act as reliable cues of alarm, or honest 'index' signals in which a signal's meaning is associated with its method of production. We show that crested pigeons, Ocyphaps lophotes, which have modified flight feathers, produce distinct wing 'whistles' in alarmed flight, and that individuals take off in alarm only after playback of alarmed whistles. Furthermore, amplitude-manipulated playbacks showed that response depends on whistle structure, such as tempo, not simply amplitude. We believe this is the first demonstration that flight noise can send information about alarm, and suggest that take-off noise could provide a cue of alarm in many flocking species, with feather modification evolving specifically to signal alarm in some. Similar reliable cues or index signals could occur in other animals.

  14. Orthos, an alarm system for the ALICE DAQ operations

    Science.gov (United States)

    Chapeland, Sylvain; Carena, Franco; Carena, Wisla; Chibante Barroso, Vasco; Costa, Filippo; Denes, Ervin; Divia, Roberto; Fuchs, Ulrich; Grigore, Alexandru; Simonetti, Giuseppe; Soos, Csaba; Telesca, Adriana; Vande Vyvre, Pierre; von Haller, Barthelemy

    2012-12-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector studying the physics of strongly interacting matter and the quark-gluon plasma at the CERN LHC (Large Hadron Collider). The DAQ (Data Acquisition System) facilities handle the data flow from the detectors electronics up to the mass storage. The DAQ system is based on a large farm of commodity hardware consisting of more than 600 devices (Linux PCs, storage, network switches), and controls hundreds of distributed hardware and software components interacting together. This paper presents Orthos, the alarm system used to detect, log, report, and follow-up abnormal situations on the DAQ machines at the experimental area. The main objective of this package is to integrate alarm detection and notification mechanisms with a full-featured issues tracker, in order to prioritize, assign, and fix system failures optimally. This tool relies on a database repository with a logic engine, SQL interfaces to inject or query metrics, and dynamic web pages for user interaction. We describe the system architecture, the technologies used for the implementation, and the integration with existing monitoring tools.

  15. Encountering bird alarms in full-stare IRSTs

    Science.gov (United States)

    de Jong, Arie N.; Winkel, Hans; Kemp, Rob A. W.

    2000-12-01

    Birds are a potential source of frequent false alarms in Infrared Search and Track (IRST) systems. One reason is that the signals, generated by birds at short ranges (1-2 km) in IR sensors may be of the same magnitude as the signals generated by real targets (missiles) at long ranges (10-20 km). Another reason is that new generations of IRSTs have more sensitivity which brings more birds within the detection range. Furthermore military operations tend to be held more and more in coastal zones, where the frequency of occurrence of birds is greater than in the open ocean. Finally, the variety in type of birds and their flight characteristics and signature is larger. In the paper attention is spent on the IR signatures of birds in various backgrounds, including rapid variations in signature due to wing motions. Basically, these fluctuations and the flight pattern of a bird provide opportunities to encounter bird alarms in next generation IRSTs, using multiple Focal Plan Array cameras with high frame rates. One has to take into account in this process the difference between signal variations due to wing motions and scintillation for long range targets above the horizon.

  16. FAULT LOCALIZATION AND ALARM CORRELATION IN OPTICAL WDM NETWORKS

    Directory of Open Access Journals (Sweden)

    G.Ramesh

    2010-06-01

    Full Text Available For several high speed networks, providing resilience against failures is an essential requirement. The main feature for designing next generation optical networks is protecting and restoring high capacity WDM networks from the failures. Quick detection, identification and restoration make networks more strong and consistent even though the failures cannot be avoided. Hence, it is necessary to develop fast, efficient and dependable fault localization or detection mechanisms. In this paper we propose a new fault localization algorithm for WDM networks which can identify the location of a failure on a failed lightpath. Our algorithm detects the failed connection and then attempts to reroute data stream through an alternate path. In addition to this, we develop an algorithm to analyze the information of the alarms generated by the components of an optical network, in the presence of a fault. It uses the alarm correlation in order to reduce the list of suspected components shown to the network operators. By our simulation results, we show that our proposed algorithms achieve less blocking probability and delay while getting higher throughput.

  17. Dynamic capabilities, Marketing Capability and Organizational Performance

    Directory of Open Access Journals (Sweden)

    Adriana Roseli Wünsch Takahashi

    2017-01-01

    Full Text Available The goal of the study is to investigate the influence of dynamic capabilities on organizational performance and the role of marketing capabilities as a mediator in this relationship in the context of private HEIs in Brazil. As a research method we carried out a survey with 316 IES and data analysis was operationalized with the technique of structural equation modeling. The results indicate that the dynamic capabilities have influence on organizational performance only when mediated by marketing ability. The marketing capability has an important role in the survival, growth and renewal on educational services offerings for HEIs in private sector, and consequently in organizational performance. It is also demonstrated that mediated relationship is more intense for HEI with up to 3,000 students and other organizational profile variables such as amount of courses, the constitution, the type of institution and type of education do not significantly alter the results.

  18. Model Indepedent Vibration Control

    OpenAIRE

    Yuan, Jing

    2010-01-01

    A NMIFC system is proposed for broadband vibration control. It has two important features. Feature F1 is that the NMIFC is stable without introducing any invasive effects, such as probing signals or controller perturbations, into the vibration system; feature F2 is

  19. Vibration Theory, Vol. 3

    DEFF Research Database (Denmark)

    Nielsen, Søren R. K.

    The present textbook has been written based on previous lecture notes for a course on stochastic vibration theory that is being given on the 9th semester at Aalborg University for M. Sc. students in structural engineering. The present 4th edition of this textbook on linear stochastic vibration...

  20. Vibration Theory, Vol. 3

    DEFF Research Database (Denmark)

    Nielsen, Søren R. K.

    The present textbook has been written based on previous lecture notes for a course on stochastic vibration theory that is being given on the 9th semester at Aalborg University for M. Sc. students in structural engineering. The present 2nd edition of this textbook on linear stochastic vibration...

  1. Hydroelastic Vibrations of Ships

    DEFF Research Database (Denmark)

    Jensen, Jørgen Juncher; Folsø, Rasmus

    2002-01-01

    A formula for the necessary hull girder bending stiffness required to avoid serious springing vibrations is derived. The expression takes into account the zero crossing period of the waves, the ship speed and main dimensions. For whipping vibrations the probability of exceedance for the combined...

  2. Gearbox vibration diagnostic analyzer

    Science.gov (United States)

    1992-01-01

    This report describes the Gearbox Vibration Diagnostic Analyzer installed in the NASA Lewis Research Center's 500 HP Helicopter Transmission Test Stand to monitor gearbox testing. The vibration of the gearbox is analyzed using diagnostic algorithms to calculate a parameter indicating damaged components.

  3. Mechanical vibration and shock analysis, sinusoidal vibration

    CERN Document Server

    Lalanne, Christian

    2014-01-01

    Everything engineers need to know about mechanical vibration and shock...in one authoritative reference work! This fully updated and revised 3rd edition addresses the entire field of mechanical vibration and shock as one of the most important types of load and stress applied to structures, machines and components in the real world. Examples include everything from the regular and predictable loads applied to turbines, motors or helicopters by the spinning of their constituent parts to the ability of buildings to withstand damage from wind loads or explosions, and the need for cars to m

  4. The effectiveness of nurse education and training for clinical alarm response and management: a systematic review.

    Science.gov (United States)

    Yue, Liqing; Plummer, Virginia; Cross, Wendy

    2017-09-01

    To identify the effectiveness of education interventions provided for nurses for clinical alarm response and management. Some education has been undertaken to improve clinical alarm response, but the evidence for evaluating effectiveness for nurse education interventions is limited. Systematic review. A systematic review of experimental studies published in English from 2005-2015 was conducted in four computerised databases (MEDLINE, EMBASE, CINAHL and Scopus). After identification, screening and appraisal using Joanna Briggs Institute instruments, quality research papers were selected, data extraction and analysis followed. Five studies met the inclusion criteria for alarm response and no articles were concerned with clinical alarm education for management. All had different types and methods of interventions and statistical pooling was not possible. Response accuracy, response time and perceptions were consistent when different interventions were adopted. A positive effect was identified when learning about general alarms, single alarms, sequential alarms and medium-level alarms for learning as the primary task. Nurses who were musically trained had a faster and more accurate alarm response. Simulation interventions had a positive effect, but the effect of education provided in the care unit was greater. Overall, clinical alarm awareness was improved through education activities. Nurses are the main users of healthcare alarms and work in complex environments with high numbers of alarms, including nuisance alarms and other factors. Alarm-related adverse events are common. The findings of a small number of experimental studies with diverse evidence included consideration of various factors when formulating education strategies. The factors which influence effectiveness of nurse education are nurse demographics, nurse participants with musical training, workload and characteristics of alarms. Education interventions based in clinical practice settings increase

  5. Vibrations of rotating machinery

    CERN Document Server

    Matsushita, Osami; Kanki, Hiroshi; Kobayashi, Masao; Keogh, Patrick

    2017-01-01

    This book opens with an explanation of the vibrations of a single degree-of-freedom (dof) system for all beginners. Subsequently, vibration analysis of multi-dof systems is explained by modal analysis. Mode synthesis modeling is then introduced for system reduction, which aids understanding in a simplified manner of how complicated rotors behave. Rotor balancing techniques are offered for rigid and flexible rotors through several examples. Consideration of gyroscopic influences on the rotordynamics is then provided and vibration evaluation of a rotor-bearing system is emphasized in terms of forward and backward whirl rotor motions through eigenvalue (natural frequency and damping ratio) analysis. In addition to these rotordynamics concerning rotating shaft vibration measured in a stationary reference frame, blade vibrations are analyzed with Coriolis forces expressed in a rotating reference frame. Other phenomena that may be assessed in stationary and rotating reference frames include stability characteristic...

  6. The impact of recent changes in smoke alarm legislation on residential fire injuries and smoke alarm ownership in New South Wales, Australia.

    Science.gov (United States)

    Harvey, Lara A; Poulos, Roslyn G; Sherker, Shauna

    2013-01-01

    In 2006, New South Wales (NSW) state legislation changed from requiring smoke alarms in new houses only to all houses. We evaluated the impact of this legislative change on residential fire injury and smoke alarm ownership characteristics. Residential fire injuries for 2002 to 2010 were identified from hospitalization data for all hospitals in NSW. Data relating to smoke alarm ownership and demographic factors were obtained from the NSW Population Health Survey. Negative binomial regression analysis was used to analyze trends over time. Prior to the introduction of universal legislation, hospitalization rates were increasing slightly; however, following the introduction of legislation, hospitalization rates decreased by an estimated 36.2% (95% confidence interval [CI], 16.7-55.8) annually. Smoke alarm ownership increased from 73.3% (95% CI, 72.5-74.2) prelegislation to 93.6% (95% CI, 93.1-94.2) 18 months postlegislation. Thirty percent of households reported testing their alarms regularly. Speaking a language other than English (relative risks [RRs], 1.82; 95% CI, 1.44-2.99), allowing smoking in the home (RR, 1.73; 95% CI, 1.31-2.27), and being part of the most disadvantaged socioeconomic group (RR, 1.47; 95% CI, 1.14-1.91) remain major risk factors for nonownership. Broadening the scope of state legislation has had a positive impact on residential fire-related hospitalizations and smoke alarm ownership. However, it is of concern that the legislation has been the least effective in increasing smoke alarm ownership among non-English-speaking households, in households where smoking is allowed, in low socioeconomic households, and that a high proportion of householders do not test their smoke alarms regularly. Targeted campaigns are needed to reach these high-risk groups and to ensure that smoke alarms are functional.

  7. Power Harvesting Capabilities of SHM Ultrasonic Sensors

    Directory of Open Access Journals (Sweden)

    Christophe Delebarre

    2012-01-01

    Full Text Available The aim of this work is to show that classical Structural Health Monitoring ultrasonic sensors may provide some power harvesting capabilities from a wide variety of vibration sources. In other words, the authors developed an integrated piezoelectric energy harvesting sensor capable of operating a dual mode, that is, carrying out vibration power harvesting and Structural Health Monitoring. First, vibrations signals of an A380 aircraft recorded during different phases of flight are presented to show the need of a wideband piezoelectric energy harvester. Then, the voltage response of a piezoelectric power harvester bonded onto an aluminium cantilever plate and excited by an electromechanical shaker is measured. A finite element model of the energy harvester system is also presented. This model provides the voltage response of the harvester due to a mechanical excitation of the host structure and allows a better understanding of the energy harvesting process. In many cases, a good agreement with the experimental results is obtained. A power measurement also showed the ability of piezoelectric SHM sensors to harvest power over an extended frequency range present in spectra collected in aircrafts. This result could lead to numerous applications even though this kind of power harvester sensor has been initially designed to operate onboard aircrafts.

  8. Vibrational dephasing in matter-wave interferometers

    Science.gov (United States)

    Rembold, A.; Schütz, G.; Röpke, R.; Chang, W. T.; Hwang, I. S.; Günther, A.; Stibor, A.

    2017-03-01

    Matter-wave interferometry is a highly sensitive tool to measure small perturbations in a quantum system. This property allows the creation of precision sensors for dephasing mechanisms such as mechanical vibrations. They are a challenge for phase measurements under perturbing conditions that cannot be perfectly decoupled from the interferometer, e.g. for mobile interferometric devices or vibrations with a broad frequency range. Here, we demonstrate a method based on second-order correlation theory in combination with Fourier analysis, to use an electron interferometer as a sensor that precisely characterizes the mechanical vibration spectrum of the interferometer. Using the high spatial and temporal single-particle resolution of a delay line detector, the data allows to reveal the original contrast and spatial periodicity of the interference pattern from ‘washed-out’ matter-wave interferograms that have been vibrationally disturbed in the frequency region between 100 and 1000 Hz. Other than with electromagnetic dephasing, due to excitations of higher harmonics and additional frequencies induced from the environment, the parts in the setup oscillate with frequencies that can be different to the applied ones. The developed numerical search algorithm is capable to determine those unknown oscillations and corresponding amplitudes. The technique can identify vibrational dephasing and decrease damping and shielding requirements in electron, ion, neutron, atom and molecule interferometers that generate a spatial fringe pattern on the detector plane.

  9. Predictive combinations of monitor alarms preceding in-hospital code blue events.

    Science.gov (United States)

    Hu, Xiao; Sapo, Monica; Nenov, Val; Barry, Tod; Kim, Sunghan; Do, Duc H; Boyle, Noel; Martin, Neil

    2012-10-01

    Bedside monitors are ubiquitous in acute care units of modern healthcare enterprises. However, they have been criticized for generating an excessive number of false positive alarms causing alarm fatigue among care givers and potentially compromising patient safety. We hypothesize that combinations of regular monitor alarms denoted as SuperAlarm set may be more indicative of ongoing patient deteriorations and hence predictive of in-hospital code blue events. The present work develops and assesses an alarm mining approach based on finding frequent combinations of single alarms that are also specific to code blue events to compose a SuperAlarm set. We use 4-way analysis of variance (ANOVA) to investigate the influence of four algorithm parameters on the performance of the data mining approach. The results are obtained from millions of monitor alarms from a cohort of 223 adult code blue and 1768 control patients using a multiple 10-fold cross-validation experiment setup. Using the optimal setting of parameters determined in the cross-validation experiment, final SuperAlarm sets are mined from the training data and used on an independent test data set to simulate running a SuperAlarm set against live regular monitor alarms. The ANOVA shows that the content of a SuperAlarm set is influenced by a subset of key algorithm parameters. Simulation of the extracted SuperAlarm set shows that it can predict code blue events one hour ahead with sensitivity between 66.7% and 90.9% while producing false SuperAlarms for control patients that account for between 2.2% and 11.2% of regular monitor alarms depending on user-supplied acceptable false positive rate. We conclude that even though the present work is still preliminary due to the usage of a moderately-sized database to test our hypothesis it represents an effort to develop algorithms to alleviate the alarm fatigue issue in a unique way. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus).

    Science.gov (United States)

    Deng, Huaiqing; Gao, Kai; Zhou, Jiang

    2016-09-30

    Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002-2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7-10 min) followed by longer variable-frequency mobbing calls lasting 5-12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520-1000 Hz and 690-3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates' species. The system of vocal alarm behavior described in this critically endangered species is simple and effective.

  11. Development of Alarm System link Drawing for Operation Support for APR1400 Digital Main Control Room

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki-Hwan [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    Digitalized MMI(Man-Machine Interface) including Digital Main Control Room(MCR) and digital I and C system was being applied for SKN 3 and 4 Nuclear Power Plant(NPP) and subsequent APR1400 NPP type. But, operators can not easily find instrument for alarm immediately. Therefore, Alarm system is required to easily find instrument for Alarm. For this implementation, we will plan system design considering design feature without affecting network load and CPU load. We have developed Alarm system link drawing for digital MCR. Operators of the digitalized MCR navigates from their consoles to the drawings related to the plant alarms and their instruments or the operation status. Such method gives cognitive load to the operators having to travel to different locations in finding the related information. Screen Sharing System, which is the fundamental technique for Drawing Interconnection Alarm System is close to completion, and it should be functionally tested and verified by the human factor engineering. For the actual application to the operating plants, the drawings to be interconnected to the alarms and the opinions from the operators/maintenance departments for designating alarm number should be surveyed, Also, another function that allows the access to the alarm related drawings not only from the MCR but also from the other offices.

  12. A Human Factors Perspective on Alarm System Research and Development 2000 to 2010

    Energy Technology Data Exchange (ETDEWEB)

    Curt Braun; John Grimes; Eric Shaver; Ronald Boring (Principal Investigator)

    2011-09-01

    By definition, alarms serve to notify human operators of out-of-parameter conditions that could threaten equipment, the environment, product quality and, of course, human life. Given the complexities of industrial systems, human machine interfaces, and the human operator, the understanding of how alarms and humans can best work together to prevent disaster is continually developing. This review examines advances in alarm research and development from 2000 to 2010 and includes the writings of trade professionals, engineering and human factors researchers, and standards organizations with the goal of documenting advances in alarms system design, research, and implementation.

  13. Clinical Trial of an Educational Program to Decrease Monitor Alarms in a Medical Intensive Care Unit.

    Science.gov (United States)

    Brantley, Arian; Collins-Brown, Sandra; Kirkland, Jasmine; Knapp, Meghan; Pressley, Jackie; Higgins, Melinda; McMurtry, James P

    2016-07-01

    Clinical research to identify effective interventions for decreasing nonactionable alarms has been limited. The objective of this study was to determine if a staff educational program on customizing alarm settings on bedside monitors decreased alarms in a medical intensive care unit (MICU). A preintervention, postintervention, nonequivalent group design was used to evaluate an educational program on alarm management in a convenience sample of MICU nurses. A 15-minute session was provided in a 1-week period. The outcome variable (number of alarms for low oxygen saturation via pulse oximetry [SpO2]) was determined from monitor log files adjusted by patient census. Data were collected for 15 days before and after the intervention. χ2 analysis was used, with P less than .05 considered significant. After 1 week of education, low SpO2 alarms decreased from 502 to 306 alarms per patient monitored per day, a 39% reduction (P < .001). Instructions for nurses in the medical intensive care unit on individualizing alarm settings to patients' clinical condition decreased common monitor alarms by 39%. ©2016 American Association of Critical-Care Nurses.

  14. A new fire alarm system for electrical installations

    CERN Document Server

    Pietersen, A H

    1978-01-01

    Fires in electrical installations are considered to develop in four phases - initiation, smouldering, flame formation and heat development. Cables are among the more sensitive components, with working temperatures around 50 degrees C and fire detection at 70 degrees C. Conventional alarms include smoke detectors. The new technique described uses microcapsules containing powder forming a gas of the Freon type after diffusion. A typical microcapsule loses 4% per year and has a natural life of 10 years. Fabrication methods are described. Detection is by gas concentration, with a sensitivity of 1 to 10 ppm, or by acoustic methods with microphones to pick up the sound of fractures. Pressure/temperature characteristics of various types of Freon mixtures commercially available are given in graphical form.

  15. A methodology of alarm filtering using dynamic fault tree

    Energy Technology Data Exchange (ETDEWEB)

    Simeu-Abazi, Zineb, E-mail: Zineb.Simeu-Abazi@g-scop.inpg.f [Laboratory G-SCOP (CNRS-INPG-UJF), 46 Avenue Felix Viallet, 38000 Grenoble (France); Lefebvre, Arnaud, E-mail: arnaud.lefebvre@eurocopter.co [EUROCOPTER (France); Derain, Jean-Pierre, E-mail: Jean-pierre.derain@eurocopter.co [EUROCOPTER (France)

    2011-02-15

    This article presents a new approach for filtering the faults, thanks to the defined dynamic fault tree (DFT). The proposed methodology includes the dependencies between fault events in the models. Two problems must thus be solved: they relate to the filtering of false alarms, and the reduction of the size of the ambiguity of fault isolation related to the occurrence of a failure. In response to the expressed need for diagnosis, as well as for the need for filtering and localization of the failures, it is necessary to introduce new dynamic gates, making it possible to translate new dependencies, relationships. Based on previous techniques, the approach presented in this paper is based on four peculiar powerful features. First, the concept of the precedence between events is taken into account in order to resort to an adapted configuration for the fault isolation. Second, another relevant data to establish a diagnosis is to take into account the concepts of redundancies between various sets. The appearance of the same phenomenon on various sets can make it possible to refine the fault isolation. The knowledge of the character of the failures is a third important concept; indeed according to the character of the identified breakdowns, one will be able for example to refine the localization or to filter certain events considered non-representative of the character of the breakdown. Fourth, the time duration of the alarm is a more interesting resource to be exploited. The proposed DFT model can be modularized and each module translated into a High Level Petri Net (HLPN). Translation of DFT modules into HLPN has proved to be very flexible and various kinds of new dependencies can be easily accommodated. In order to exploit this flexibility a new representation, called the event diagram, is introduced.

  16. Structural Stability and Vibration

    DEFF Research Database (Denmark)

    Wiggers, Sine Leergaard; Pedersen, Pauli

    This book offers an integrated introduction to the topic of stability and vibration. Strikingly, it describes stability as a function of boundary conditions and eigenfrequency as a function of both boundary conditions and column force. Based on a post graduate course held by the author at the Uni......This book offers an integrated introduction to the topic of stability and vibration. Strikingly, it describes stability as a function of boundary conditions and eigenfrequency as a function of both boundary conditions and column force. Based on a post graduate course held by the author...... and their derivation, thus stimulating them to write interactive and dynamic programs to analyze instability and vibrational modes....

  17. Capabilities for Strategic Adaptation

    DEFF Research Database (Denmark)

    Distel, Andreas Philipp

    This dissertation explores capabilities that enable firms to strategically adapt to environmental changes and preserve competitiveness over time – often referred to as dynamic capabilities. While dynamic capabilities being a popular research domain, too little is known about what these capabilities...... on capabilities for sensing and seizing new business opportunities and reconfiguring corporate resources. More specifically, the dissertation examines the role of key organization members, such as knowledge workers and top managers, in defining and building these capabilities. Moreover, it investigates how...... empirical studies through the dynamic capabilities lens and develops propositions for future research. The second paper is an empirical study on the origins of firm-level absorptive capacity; it explores how organization-level antecedents, through their impact on individual-level antecedents, influence...

  18. Vibration Analysis and the Accelerometer

    Science.gov (United States)

    Hammer, Paul

    2011-01-01

    Have you ever put your hand on an electric motor or motor-driven electric appliance and felt it vibrate? Ever wonder why it vibrates? What is there about the operation of the motor, or the object to which it is attached, that causes the vibrations? Is there anything "regular" about the vibrations, or are they the result of random causes? In this…

  19. Prioritizing alarms from sensor-based detection models in livestock production - A review on model performance and alarm reducing methods

    DEFF Research Database (Denmark)

    Dominiak, Katarina Sylow; Kristensen, Anders Ringgaard

    2017-01-01

    to be improved through the combination of different methods (12 papers) and “Prioritizing models” where the models include a method of ranking or prioritizing alerts in order to reduce the number of false alarms (3 papers). Of the three methods that rank or prioritize alerts; Fuzzy Logic, Naive Bayesian Network...... (NBN) and Hidden phase-type Markov model, the NBN shows the greatest potential for future reduction of alerts from sensor-based detection models in livestock production. The included detection models are evaluated on three criteria; performance, time-window and similarity to determine whether...... monitoring and early warning systems offer an opportunity to observe certain aspects of animal health, welfare, and productivity more closely than traditionally accomplished through human observation, and the opportunities for improving animal welfare should continue to be a driving force throughout...

  20. Vibrations and Stability

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel

    About this textbook An ideal text for students that ties together classical and modern topics of advanced vibration analysis in an interesting and lucid manner. It provides students with a background in elementary vibrations with the tools necessary for understanding and analyzing more complex...... dynamical phenomena that can be encountered in engineering and scientific practice. It progresses steadily from linear vibration theory over various levels of nonlinearity to bifurcation analysis, global dynamics and chaotic vibrations. It trains the student to analyze simple models, recognize nonlinear...... phenomena and work with advanced tools such as perturbation analysis and bifurcation analysis. Explaining theory in terms of relevant examples from real systems, this book is user-friendly and meets the increasing interest in non-linear dynamics in mechanical/structural engineering and applied mathematics...

  1. Cooperative Engagement Capability (CEC)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-582 Cooperative Engagement Capability (CEC) As of FY 2017 President’s Budget Defense...Program Information Program Name Cooperative Engagement Capability (CEC) DoD Component Navy Joint Participants United States Marine Corps; United...dated June 16, 2004 CEC December 2015 SAR March 17, 2016 12:13:59 UNCLASSIFIED 5 Mission and Description Mission The Cooperative Engagement Capability

  2. A note on alarm cues in juvenile African catfish, Clarias gariepinus: Indications for opposing behavioural strategies.

    NARCIS (Netherlands)

    Nieuwegiessen, van de P.G.; Schrama, J.W.; Verreth, J.A.J.

    2008-01-01

    Following exposure of African catfish to alarm cues, a relationship (rp=0.60, N=10, P=0.07) between feed efficiency (measured as residual feed intake) and the change in percentage of time spent swimming in response to damage-released alarm cues was observed. Feed-efficient animals responded with a

  3. Characteristics of the alarm calls of buff-streaked chat groups and ...

    African Journals Online (AJOL)

    Many animals emit alarm calls in response to a potential predator. These calls may transmit information about predator type and response urgency. This study compared the alarm calls of the social buff-streaked chat, Oenanthe bifasciata, to the asocial African stonechat, Saxicola torquata. Spring traps were used to capture ...

  4. 76 FR 76327 - Installation of Radiation Alarms for Rooms Housing Neutron Sources

    Science.gov (United States)

    2011-12-07

    ... COMMISSION 10 CFR Part 73 Installation of Radiation Alarms for Rooms Housing Neutron Sources AGENCY: Nuclear... radiation alarms in rooms housing neutron sources. DATES: Submit comments by February 21, 2012. Comments..., Radiation Safety for Research. Mr. Hamawy is concerned about the security of neutron sources. III. Petition...

  5. Analysis of stabilization quality false alarm probability by a radar adaptive detector in order statistics

    OpenAIRE

    Andreev, F. M.; Taranchenko, I. V.

    2007-01-01

    New expressions are derived for estimating the false alarm probability by adaptive threshold detectors, using the method of averaging and method of order statistics, in the presence of nonstationary interference. Potentialities of these devices, from the viewpoint of their stabilization of false alarm probability in the presence of nonstationary interference, are defined, and comparative analysis of the devices is performed.

  6. Alarm of monitoring invasive of blood pressure: are we giving the attention required?

    Directory of Open Access Journals (Sweden)

    Adele Kuckartz Pergher

    2015-10-01

    Full Text Available O elevado número de alarmes sem relevância nas UTIs podem resultar em um retardo no tempo de reposta a alarmes relevantes. Objetivos: Identificar porque soam os alarmes de pressão arterial invasiva (PAI e o tempo de resposta da equipe, descrever as condutas estabelecidas para saná-los. Métodos: Pesquisa descritiva de abordagem quanti/qualitativa. A observação ocorreu em uma UTI adulto de um hospital militar no Rio de Janeiro. Foi aprovada pelo Comitê de Ética em Pesquisa da Universidade Federal do Estado do Rio de Janeiro (CAAE 03284612.4.3001.5250. Considerou-se fatigados alarmes não atendidos em 10 minutos, ou que paravam de soar antes de terem sidos atendidos. Resultados: Registraram-se 76 alarmes de PAI; 21 (28% foram atendidos, em média em 2,45 min. 55 (72% alarmes foram considerados fatigados. Conclusão: O elevado número de alarmes fatigados representam risco. É um desafio responder a todos os alarmes considerando a relação enfermeiro/ paciente imposta pela ANVISA.

  7. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo pressure or temperature alarms required. 153.438... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a...

  8. Use of alarm features in referral of febrile children to the emergency department : an observational study

    NARCIS (Netherlands)

    van Ierland, Yvette; Elshout, Gijs; Moll, Henritte A.; Nijman, Ruud G.; Vergouwe, Yvonne; van der Lei, Johan; Berger, Marjolein Y.; Oostenbrink, Rianne

    Background The diagnostic value of alarm features of serious infections in low prevalence settings is unclear. Aim To explore to what extent alarm features play a role in referral to the emergency department (ED) by GPs who face a febrile child during out-of-hours care. Design and setting

  9. Writing short alarm messages : A matter of education, training and practice

    NARCIS (Netherlands)

    Jagtman, H.M.

    2013-01-01

    The Netherlands has a new tool to alarm and inform the population in case of crises. NL-Alert can simultaneously draw people’s attention and explain the crisis matter. The use requires determining of both the impact area and the alarm text. This raises questions about required knowledge and

  10. Design for safety : A new service for alarming and informing the population in case of emergency

    NARCIS (Netherlands)

    Jagtman, H.M.

    2012-01-01

    In case of emergencies the population in danger should be alarmed so individuals can take action to get or remain out of danger. For alarming the population the means available are limited. Many countries have outdoor sirens. They operability however is limited since the siren has only one implicit

  11. Suppression of false arrhythmia alarms in the ICU: a machine learning approach.

    Science.gov (United States)

    Ansari, Sardar; Belle, Ashwin; Ghanbari, Hamid; Salamango, Mark; Najarian, Kayvan

    2016-08-01

    This paper presents a novel approach for false alarm suppression using machine learning tools. It proposes a multi-modal detection algorithm to find the true beats using the information from all the available waveforms. This method uses a variety of beat detection algorithms, some of which are developed by the authors. The outputs of the beat detection algorithms are combined using a machine learning approach. For the ventricular tachycardia and ventricular fibrillation alarms, separate classification models are trained to distinguish between the normal and abnormal beats. This information, along with alarm-specific criteria, is used to decide if the alarm is false. The results indicate that the presented method was effective in suppressing false alarms when it was tested on a hidden validation dataset.

  12. West-Coast Wide Expansion and Testing of the Geodetic Alarm System (G-larmS)

    Science.gov (United States)

    Ruhl, C. J.; Grapenthin, R.; Melgar, D.; Aranha, M. A.; Allen, R. M.

    2016-12-01

    The Geodetic Alarm System (G-larmS) was developed in collaboration between the Berkeley Seismological Laboratory (BSL) and New Mexico Tech for real-time Earthquake Early Warning (EEW). G-larmS has been in continuous operation at the BSL since 2014 using event triggers from the ShakeAlert EEW system and real-time position time series from a fully triangulated network consisting of BARD, PBO and USGS stations across northern California (CA). G-larmS has been extended to include southern CA and Cascadia, providing continuous west-coast wide coverage. G-larmS currently uses high rate (1 Hz), low latency (6.5) in CA and Cascadia built from realistic 3D geometries. Synthetic long-period 1Hz displacement waveforms were obtained from a new stochastic kinematic slip distribution generation method. Waveforms are validated by direct comparison to peak P-wave displacement scaling laws and to PGD GMPEs obtained from high-rate GPS observations of large events worldwide. We run the scenarios on real-time streams to systematically test the recovery of slip and magnitude by G-larmS. In addition to presenting these results, we will discuss new capabilities, such as implementing 2D geometry and the applicability of these results to GPS enhanced tsunami warning systems.

  13. Telematics Options and Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Hodge, Cabell [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-05

    This presentation describes the data tracking and analytical capabilities of telematics devices. Federal fleet managers can use the systems to keep their drivers safe, maintain a fuel efficient fleet, ease their reporting burden, and save money. The presentation includes an example of how much these capabilities can save fleets.

  14. Behavioral responses of Pacific lamprey to alarm cues

    Science.gov (United States)

    Porter, Laurie L.; Hayes, Michael C.; Jackson, Aaron D.; Burke, Brian J.; Moser, Mary L.; Wagner, R. Steven

    2017-01-01

    Pacific lamprey (Entosphenus tridentatus), an anadromous ectoparasite, faces several challenges during adult migration to spawning grounds. Developing methods to address these challenges is critical to the success of ongoing conservation efforts. The challenges are diverse, and include anthropogenic alterations to the ecosystem resulting in loss of habitat, impassable barriers such as dams, climate change impacts, and altered predator fields. We conducted a behavioral study to understand how adult migrating Pacific lamprey respond to potential alarm cues: White Sturgeon (Acipenser transmontanus), human saliva, decayed Pacific lamprey, and river otter (Lontra canadensis). Research has shown that some species of lamprey can be guided to a location using odors and similar cues may be useful as a management tool for Pacific lamprey. Experiments were conducted over 2 nights and measured the number of entries (count) and duration of time spent (occupancy) by adult lamprey in each arm of a two-choice maze. During the first night, no odor was added to test for selection bias between arms. During the second night odor was added to one arm of the maze. Contrary to expectations, lamprey were significantly attracted to the river otter odor in both count and occupancy. No significant differences were found in the response of lamprey to the other three odors. Results from this study indicate that Pacific lamprey do respond to some odors; however, additional tests are necessary to better identify the types of odors and concentrations that elicit a repeatable response.

  15. Attention Cueing and Activity Equally Reduce False Alarm Rate in Visual-Auditory Associative Learning through Improving Memory.

    Directory of Open Access Journals (Sweden)

    Mohammad-Ali Nikouei Mahani

    Full Text Available In our daily life, we continually exploit already learned multisensory associations and form new ones when facing novel situations. Improving our associative learning results in higher cognitive capabilities. We experimentally and computationally studied the learning performance of healthy subjects in a visual-auditory sensory associative learning task across active learning, attention cueing learning, and passive learning modes. According to our results, the learning mode had no significant effect on learning association of congruent pairs. In addition, subjects' performance in learning congruent samples was not correlated with their vigilance score. Nevertheless, vigilance score was significantly correlated with the learning performance of the non-congruent pairs. Moreover, in the last block of the passive learning mode, subjects significantly made more mistakes in taking non-congruent pairs as associated and consciously reported lower confidence. These results indicate that attention and activity equally enhanced visual-auditory associative learning for non-congruent pairs, while false alarm rate in the passive learning mode did not decrease after the second block. We investigated the cause of higher false alarm rate in the passive learning mode by using a computational model, composed of a reinforcement learning module and a memory-decay module. The results suggest that the higher rate of memory decay is the source of making more mistakes and reporting lower confidence in non-congruent pairs in the passive learning mode.

  16. Dynamic Capabilities and Performance

    DEFF Research Database (Denmark)

    Wilden, Ralf; Gudergan, Siegfried P.; Nielsen, Bo Bernhard

    2013-01-01

    Dynamic capabilities are widely considered to incorporate those processes that enable organizations to sustain superior performance over time. In this paper, we argue theoretically and demonstrate empirically that these effects are contingent on organizational structure and the competitive...... intensity in the market. Results from partial least square structural equation modeling (PLS-SEM) analyses indicate that organic organizational structures facilitate the impact of dynamic capabilities on organizational performance. Furthermore, we find that the performance effects of dynamic capabilities...... are contingent on the competitive intensity faced by firms. Our findings demonstrate the performance effects of internal alignment between organizational structure and dynamic capabilities, as well as the external fit of dynamic capabilities with competitive intensity. We outline the advantages of PLS...

  17. An Early Warning System from debris flows based on ground vibration monitoring data

    Science.gov (United States)

    Arattano, Massimo; Coviello, Velio

    2015-04-01

    Among the different countermeasures that can be adopted for the mitigation of landslide hazard, Early Warning Systems (EWSs) are receiving an increasing attention. EWSs are the set of capacities needed to generate and disseminate timely and meaningful warning information to enable individuals and communities threatened by a hazard to appropriately act, in sufficient time, to reduce the possibility of harm or loss (UNEP, 2012). An EWS from debris flows can be classified into two main categories: advance and event EWSs. Advance EWSs predict the occurrence of a debris flow by monitoring hydro-meteorological conditions that may lead to its initiation. Despite their widespread adoption, these latter systems are prone to false alarms because they are heavily affected by bias between regional rainfall threshold and local conditions. Event EWSs, on the contrary, detect the occurrence of a debris flow when the process is already in progress. They usually rely on the use of algorithms for processing in real time the monitoring data. Their effectiveness depends on the reliability of those algorithms, which require long development and testing phases. A specific testing field for event EWSs has been equipped in the Gadria instrumented basin, located in the Eastern Italian Alps. A specifically designed monitoring unit capable to record data from different type of sensors and to implement aboard warning algorithms has been installed along a straight reach of the torrent. A flashing light, installed on the bank of the torrent, has been wired to this unit. The flashing light is framed by a fixed video camera that also shoots the passage of debris flows in the torrent. This provides a visual verification of the efficacy of the algorithm under test, particularly useful to show to practitioners and administrators a clear demonstration of the warning outcome. In this work, we present the performance of a warning algorithm that has been experimented in the Gadria testing field in 2013

  18. Experimental Investigation on the Material Removal of the Ultrasonic Vibration Assisted Abrasive Water Jet Machining Ceramics

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2017-01-01

    Full Text Available The ultrasonic vibration activated in the abrasive water jet nozzle is used to enhance the capability of the abrasive water jet machinery. The experiment devices of the ultrasonic vibration assisted abrasive water jet are established; they are composed of the ultrasonic vibration producing device, the abrasive supplying device, the abrasive water jet nozzle, the water jet intensifier pump, and so on. And the effect of process parameters such as the vibration amplitude, the system working pressure, the stand-off, and the abrasive diameter on the ceramics material removal is studied. The experimental result indicates that the depth and the volume removal are increased when the ultrasonic vibration is added on abrasive water jet. With the increase of vibration amplitude, the depth and the volume of material removal are also increased. The other parameters of the ultrasonic vibration assisted abrasive water jet also have an important role in the improvement of ceramic material erosion efficiency.

  19. KSC Technical Capabilities Website

    Science.gov (United States)

    Nufer, Brian; Bursian, Henry; Brown, Laurette L.

    2010-01-01

    This document is the website pages that review the technical capabilities that the Kennedy Space Center (KSC) has for partnership opportunities. The purpose of this information is to make prospective customers aware of the capabilities and provide an opportunity to form relationships with the experts at KSC. The technical capabilities fall into these areas: (1) Ground Operations and Processing Services, (2) Design and Analysis Solutions, (3) Command and Control Systems / Services, (4) Materials and Processes, (5) Research and Technology Development and (6) Laboratories, Shops and Test Facilities.

  20. Vibration-free stirling cryocooler for high definition microscopy

    Science.gov (United States)

    Riabzev, S. V.; Veprik, A. M.; Vilenchik, H. S.; Pundak, N.; Castiel, E.

    2009-12-01

    The normal operation of high definition Scanning Electronic and Helium Ion microscope tools often relies on maintaining particular components at cryogenic temperatures. This has traditionally been accomplished by using liquid coolants such as liquid Nitrogen. This inherently limits the useful temperature range to above 77 K, produces various operational hazards and typically involves elevated ownership costs, inconvenient logistics and maintenance. Mechanical coolers, over-performing the above traditional method and capable of delivering required (even below 77 K) cooling to the above cooled components, have been well-known elsewhere for many years, but their typical drawbacks, such as high purchasing cost, cooler size, low reliability and high power consumption have so far prevented their wide-spreading. Additional critical drawback is inevitable degradation of imagery performance originated from the wideband vibration export as typical for the operation of the mechanical cooler incorporating numerous movable components. Recent advances in the development of reliable, compact, reasonably priced and dynamically quiet linear cryogenic coolers gave rise to so-called "dry cooling" technologies aimed at eventually replacing the traditional use of outdated liquid Nitrogen cooling facilities. Although much improved these newer cryogenic coolers still produce relatively high vibration export which makes them incompatible with modern high definition microscopy tools. This has motivated further research activity towards developing a vibration free closed-cycle mechanical cryocooler. The authors have successfully adapted the standard low vibration Stirling cryogenic refrigerator (Ricor model K535-LV) delivering 5 W@40 K heat lift for use in vibration-sensitive high definition microscopy. This has been achieved by using passive mechanical counterbalancing of the main portion of the low frequency vibration export in combination with an active feed-forward multi

  1. Silicon Micromachined Sensor for Broadband Vibration Analysis

    Science.gov (United States)

    Gutierrez, Adolfo; Edmans, Daniel; Cormeau, Chris; Seidler, Gernot; Deangelis, Dave; Maby, Edward

    1995-01-01

    The development of a family of silicon based integrated vibration sensors capable of sensing mechanical resonances over a broad range of frequencies with minimal signal processing requirements is presented. Two basic general embodiments of the concept were designed and fabricated. The first design was structured around an array of cantilever beams and fabricated using the ARPA sponsored multi-user MEMS processing system (MUMPS) process at the Microelectronics Center of North Carolina (MCNC). As part of the design process for this first sensor, a comprehensive finite elements analysis of the resonant modes and stress distribution was performed using PATRAN. The dependence of strain distribution and resonant frequency response as a function of Young's modulus in the Poly-Si structural material was studied. Analytical models were also studied. In-house experimental characterization using optical interferometry techniques were performed under controlled low pressure conditions. A second design, intended to operate in a non-resonant mode and capable of broadband frequency response, was proposed and developed around the concept of a cantilever beam integrated with a feedback control loop to produce a null mode vibration sensor. A proprietary process was used to integrat a metal-oxide semiconductor (MOS) sensing device, with actuators and a cantilever beam, as part of a compatible process. Both devices, once incorporated as part of multifunction data acquisition and telemetry systems will constitute a useful system for NASA launch vibration monitoring operations. Satellite and other space structures can benefit from the sensor for mechanical condition monitoring functions.

  2. Capabilities for innovation

    DEFF Research Database (Denmark)

    Nielsen, Peter; Nielsen, René Nesgaard; Bamberger, Simon Grandjean

    2012-01-01

    between employers and employees are expected to be of vital importance. This article will follow a resource-based perspective on developing dynamic capabilities in order to test the importance of enhancing human and organizational capabilities for innovation in firms. In particular, the article will focus...... on some of the important institutional conditions in Danish firms derived from the Nordic model, such as the formal and informal relations of cooperation between employers and employees in firms and their function in building capabilities for innovation. The foundation of the empirical analysis...... and in particular their ability to develop firm-specific innovative capabilities through employee participation and creation of innovative workplaces. In this article, we argue that national institutional conditions can play an enhancing or hampering role in this. Especially the norms and values governing relations...

  3. Vibrational spectroscopy of resveratrol

    Science.gov (United States)

    Billes, Ferenc; Mohammed-Ziegler, Ildikó; Mikosch, Hans; Tyihák, Ernő

    2007-11-01

    In this article the authors deal with the experimental and theoretical interpretation of the vibrational spectra of trans-resveratrol (3,5,4'-trihydroxy- trans-stilbene) of diverse beneficial biological activity. Infrared and Raman spectra of the compound were recorded; density functional calculations were carried out resulting in the optimized geometry and several properties of the molecule. Based on the calculated force constants, a normal coordinate analysis yielded the character of the vibrational modes and the assignment of the measured spectral bands.

  4. Bumblebee vibration activated foraging

    OpenAIRE

    Su, Dan Kuan-Nien

    2009-01-01

    The ability use vibrational signals to activate nestmate foraging is found in the highly social bees, stingless bees and honey bees, and has been hypothesized to exist in the closely related, primitively eusocial bumble bees. We provide the first strong and direct evidence that this is correct. Inside the nest, bumble bee foragers produce brief bursts of vibration (foraging activation pulses) at 594.5 Hz for 63±26 ms (velocityRMS=0.46±0.02mm/s, forceRMS=0.8±0.2 mN. Production of these vibrati...

  5. Man-Induced Vibrations

    DEFF Research Database (Denmark)

    Jönsson, Jeppe; Hansen, Lars Pilegaard

    1994-01-01

    concerned with spectator-induced vertical vibrations on grandstands. The idea is to use impulse response analysis and base the load description on the load impulse. If the method is feasable, it could be used in connection with the formulation of requirements in building codes. During the last two decades...... work has been done on the measurement of the exact load functions and related reponse analysis. A recent work using a spectral description has been performed by Per-Erik Erikson and includes a good literature survey. Bachmann and Ammann give a good overview of vibrations caused by human activity. Other...

  6. Vibrations and waves

    CERN Document Server

    Kaliski, S

    2013-01-01

    This book gives a comprehensive overview of wave phenomena in different media with interacting mechanical, electromagnetic and other fields. Equations describing wave propagation in linear and non-linear elastic media are followed by equations of rheological models, models with internal rotational degrees of freedom and non-local interactions. Equations for coupled fields: thermal, elastic, electromagnetic, piezoelectric, and magneto-spin with adequate boundary conditions are also included. Together with its companion volume Vibrations and Waves. Part A: Vibrations this work provides a wealth

  7. Capabilities and social cohesion

    OpenAIRE

    Diego Lanzi

    2011-01-01

    The paper connects the concepts of well-being and social cohesion. By using Sen's capability approach to well-being, and analysing the socio-psychological literature on cohesiveness in groups and communities, we explain when social cohesion has positive effects on the development of social capabilities and human well-being. Furthermore, we discuss cases and conditions in which stronger social cohesion may delay the achievement of the kind of goals Sen has in mind. Finally, we suggest a multid...

  8. CASL Dakota Capabilities Summary

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Brian M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Simmons, Chris [Univ. of Texas, Austin, TX (United States); Williams, Brian J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-10

    The Dakota software project serves the mission of Sandia National Laboratories and supports a worldwide user community by delivering state-of-the-art research and robust, usable software for optimization and uncertainty quantification. These capabilities enable advanced exploration and riskinformed prediction with a wide range of computational science and engineering models. Dakota is the verification and validation (V&V) / uncertainty quantification (UQ) software delivery vehicle for CASL, allowing analysts across focus areas to apply these capabilities to myriad nuclear engineering analyses.

  9. Education and Innovative Capabilities

    OpenAIRE

    Leiponen, Aija

    1996-01-01

    This study investigates the role of capabilities, acquired through education and on the job learning, in innovation. It is argued that education enhances learning and innovation because it provides employees with communication and interaction skills, and, more importantly, with abilities to receive, understand and utilize relevant knowledge, and solve problems. These dynamic capabilities are one of the sources of innovation. A dataset of 333 Finnish manufacturing firms is used to estimat...

  10. Alarm symptoms of upper gastrointestinal cancer and contact to general practice

    DEFF Research Database (Denmark)

    Rasmussen, Sanne; Larsen, Pia Veldt; Svendsen, Rikke Pilsgaard

    2015-01-01

    between 1.1% ("repeated vomiting") and 3.4% ("difficulty swallowing"). Women had higher odds of experiencing "repeated vomiting" and "persistent and recent-onset abdominal pain", but lower odds of experiencing "upper GI bleeding". The proportion of people contacting their GP with each of the four specific...... alarm symptoms ranged from 24.3% ("upper GI bleeding") to 39.9% ("repeated vomiting"). For each combination of two specific alarm symptoms, at least 52% contacted their GP. CONCLUSION: The specific alarm symptoms of upper GI cancer are not very prevalent in the general population. The proportion of GP...

  11. 40 CFR 267.34 - When must personnel have access to communication equipment or an alarm system?

    Science.gov (United States)

    2010-07-01

    ... to an internal alarm or emergency communication device, either directly or through visual or voice... communication equipment or an alarm system? 267.34 Section 267.34 Protection of Environment ENVIRONMENTAL... have access to communication equipment or an alarm system? (a) Whenever hazardous waste is being poured...

  12. Vibrational relaxation in simulated two-dimensional infrared spectra of two amide modes in solution

    NARCIS (Netherlands)

    Dijkstra, Arend G.; Jansen, Thomas la Cour; Bloem, Robbert; Knoester, Jasper

    2007-01-01

    Two-dimensional infrared spectroscopy is capable of following the transfer of vibrational energy between modes in real time. We develop a method to include vibrational relaxation in simulations of two-dimensional infrared spectra at finite temperature. The method takes into account the correlated

  13. Emergency Response Capability Baseline Needs Assessment Compliance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, John A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-09-16

    This document is the second of a two-part analysis of Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2013 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2009 BNA, the 2012 BNA document, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures.

  14. Heterogeneous Dynamics of Coupled Vibrations

    NARCIS (Netherlands)

    Cringus, Dan; Jansen, Thomas I. C.; Pshenichnikov, Maxim S.; Schoenlein, RW; Corkum, P; DeSilvestri, S; Nelson, KA; Riedle, E

    2009-01-01

    Frequency-dependent dynamics of coupled stretch vibrations of a water molecule are revealed by 2D IR correlation spectroscopy. These are caused by non-Gaussian fluctuations of the environment around the individual OH stretch vibrations.

  15. Magnetostrictively actuated control flaps for vibration reduction in helicopter rotors

    Energy Technology Data Exchange (ETDEWEB)

    Millott, T.; Friedmann, P.P. [Univ. of California, Los Angeles, CA (United States). Mechanical, Aerospace and Nuclear Engineering Dept.

    1994-12-31

    High vibration levels can impose constraints on helicopter operations and hinder passenger acceptance. Vibration reduction using blade root pitch control introduces a significant power penalty and may adversely affect the airworthiness of the flight control system. Comparable levels of vibration reduction can be achieved using considerably less power through an actively controlled trailing edge flap mounted on the blade. Such a device would have no effect on helicopter airworthiness since it is controlled by a loop separate from the primary flight control system which utilizes the swashplate. Control flap actuation using the magnetostrictive material Terfenol-D is studied in this paper by designing a minimum weight actuator, subject to a set of actuation and stress constraints. The resulting device is capable of producing vibration reduction in excess of 90% at cruise conditions.

  16. Space Logistics: Launch Capabilities

    Science.gov (United States)

    Furnas, Randall B.

    1989-01-01

    The current maximum launch capability for the United States are shown. The predicted Earth-to-orbit requirements for the United States are presented. Contrasting the two indicates the strong National need for a major increase in Earth-to-orbit lift capability. Approximate weights for planned payloads are shown. NASA is studying the following options to meet the need for a new heavy-lift capability by mid to late 1990's: (1) Shuttle-C for near term (include growth versions); and (2) the Advanced Lauching System (ALS) for the long term. The current baseline two-engine Shuttle-C has a 15 x 82 ft payload bay and an expected lift capability of 82,000 lb to Low Earth Orbit. Several options are being considered which have expanded diameter payload bays. A three-engine Shuttle-C with an expected lift of 145,000 lb to LEO is being evaluated as well. The Advanced Launch System (ALS) is a potential joint development between the Air Force and NASA. This program is focused toward long-term launch requirements, specifically beyond the year 2000. The basic approach is to develop a family of vehicles with the same high reliability as the Shuttle system, yet offering a much greater lift capability at a greatly reduced cost (per pound of payload). The ALS unmanned family of vehicles will provide a low end lift capability equivalent to Titan IV, and a high end lift capability greater than the Soviet Energia if requirements for such a high-end vehicle are defined.In conclusion, the planning of the next generation space telescope should not be constrained to the current launch vehicles. New vehicle designs will be driven by the needs of anticipated heavy users.

  17. Optomechanical proposal for monitoring microtubule mechanical vibrations

    Science.gov (United States)

    Barzanjeh, Sh.; Salari, V.; Tuszynski, J. A.; Cifra, M.; Simon, C.

    2017-07-01

    Microtubules provide the mechanical force required for chromosome separation during mitosis. However, little is known about the dynamic (high-frequency) mechanical properties of microtubules. Here, we theoretically propose to control the vibrations of a doubly clamped microtubule by tip electrodes and to detect its motion via the optomechanical coupling between the vibrational modes of the microtubule and an optical cavity. In the presence of a red-detuned strong pump laser, this coupling leads to optomechanical-induced transparency of an optical probe field, which can be detected with state-of-the art technology. The center frequency and line width of the transparency peak give the resonance frequency and damping rate of the microtubule, respectively, while the height of the peak reveals information about the microtubule-cavity field coupling. Our method opens the new possibilities to gain information about the physical properties of microtubules, which will enhance our capability to design physical cancer treatment protocols as alternatives to chemotherapeutic drugs.

  18. The challenge of localizing vehicle backup alarms: effects of passive and electronic hearing protectors, ambient noise level, and backup alarm spectral content.

    Science.gov (United States)

    Alali, Khaled A; Casali, John G

    2011-01-01

    A human factors experiment employed a hemi-anechoic sound field in which listeners were required to localize a vehicular backup alarm warning signal (both a standard and a frequency-augmented alarm) in 360-degrees azimuth in pink noise of 60 dBA and 90 dBA. Measures of localization performance included: (1) percentage correct localization, (2) percentage of right--left localization errors, (3) percentage of front-rear localization errors, and (4) localization absolute deviation in degrees from the alarm's actual location. In summary, the data demonstrated that, with some exceptions, normal hearing listeners' ability to localize the backup alarm in 360-degrees azimuth did not improve when wearing augmented hearing protectors (including dichotic sound transmission earmuffs, flat attenuation earplugs, and level-dependent earplugs) as compared to when wearing conventional passive earmuffs or earplugs of the foam or flanged types. Exceptions were that in the 90 dBA pink noise, the flat attenuation earplug yielded significantly better accuracy than the polyurethane foam earplug and both the dichotic and the custom-made diotic electronic sound transmission earmuffs. However, the flat attenuation earplug showed no benefit over the standard pre-molded earplug, the arc earplug, and the passive earmuff. Confusions of front-rear alarm directions were most significant in the 90 dBA noise condition, wherein two types of triple-flanged earplugs exhibited significantly fewer front-rear confusions than either of the electronic muffs. On all measures, the diotic sound transmission earmuff resulted in the poorest localization of any of the protectors due to the fact that its single-microphone design did not enable interaural cues to be heard. Localization was consistently more degraded in the 90 dBA pink noise as compared with the relatively quiet condition of the 60 dBA pink noise. A frequency-augmented backup alarm, which incorporated 400 Hz and 4000 Hz components to exploit the

  19. Composite Struts Would Damp Vibrations

    Science.gov (United States)

    Dolgin, Benjamin P.

    1991-01-01

    New design of composite-material (fiber/matrix laminate) struts increases damping of longitudinal vibrations without decreasing longitudinal stiffness or increasing weight significantly. Plies with opposing chevron patterns of fibers convert longitudinal vibrational stresses into shear stresses in intermediate viscoelastic layer, which dissipate vibrational energy. Composite strut stronger than aluminum strut of same weight and stiffness.

  20. Ship Vibration Design Guide

    Science.gov (United States)

    1989-07-01

    Frachtschiffen," Werft Reederie Hafen, 1925. 4-21 Noonan, E. F. "Vibration Considerations for 120,000 CM LNG Ships," NKF: Preliminary Report No. 7107, 25...Ship Response to Ice - A Second Season by C. Daley, J. W. St. John, R. Brown, J. Meyer , and I. Glen 1990 SSC-340 Ice Forces and Ship Response to Ice

  1. Compact Vibration Damper

    Science.gov (United States)

    Ivanco, Thomas G. (Inventor)

    2014-01-01

    A vibration damper includes a rigid base with a mass coupled thereto for linear movement thereon. Springs coupled to the mass compress in response to the linear movement along either of two opposing directions. A converter coupled to the mass converts the linear movement to a corresponding rotational movement. A rotary damper coupled to the converter damps the rotational movement.

  2. Vibrations and Eigenvalues

    Indian Academy of Sciences (India)

    The vibrating string problem is the source of much mathematicsand physics. This article describes Lagrange's formulationof a discretised version of the problem and its solution.This is also the first instance of an eigenvalue problem. Author Affiliations. Rajendra Bhatia1. Ashoka University, Rai, Haryana 131 029, India.

  3. Vibration Sensitive Keystroke Analysis

    NARCIS (Netherlands)

    Lopatka, M.; Peetz, M.-H.; van Erp, M.; Stehouwer, H.; van Zaanen, M.

    2009-01-01

    We present a novel method for performing non-invasive biometric analysis on habitual keystroke patterns using a vibration-based feature space. With the increasing availability of 3-D accelerometer chips in laptop computers, conventional methods using time vectors may be augmented using a distinct

  4. Integrated Vibration and Acceleration Testing to Reduce Payload Mass, Cost and Mission Risk Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a capability to provide integrated acceleration, vibration, and shock testing using a state-of-the-art centrifuge, allowing for the test of...

  5. Patient Safety Implications of Electronic Alerts and Alarms of Maternal - Fetal Status During Labor.

    Science.gov (United States)

    Simpson, Kathleen Rice; Lyndon, Audrey; Davidson, Leigh Ann

    2016-01-01

    When nurses care for women during labor, they encounter numerous alerts and alarms from electronic fetal monitors and their surveillance systems. Notifications of values of physiologic parameters for a woman and fetus that may be outside preset limits are generated via visual and audible cues. There is no standardization of these alert and alarm parameters among electronic fetal monitoring vendors in the United States, and there are no data supporting their sensitivity and specificity. Agreement among professional organizations about physiologic parameters for alerts and alarms commonly used during labor is lacking. It is unknown if labor nurses view the alerts and alarms as helpful or a nuisance. There is no evidence that they promote or hinder patient safety. This clinical issue warrants our attention as labor nurses. © 2016 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses.

  6. Real-time Alarm Monitoring System for Detecting Driver Fatigue in Wireless Areas

    Directory of Open Access Journals (Sweden)

    Rongrong Fu

    2017-04-01

    Full Text Available The purpose of this paper was to develop a real-time alarm monitoring system that can detect the fatigue driving state through wireless communication. The drivers’ electroencephalogram (EEG signals were recorded from occipital electrodes. Seven EEG rhythms with different frequency bands as gamma, hbeta, beta, sigma, alpha, theta and delta waves were extracted. They were simultaneously assessed using relative operating characteristic (ROC curves and grey relational analysis to select one as the fatigue feature. The research results showed that the performance of theta wave was the best one. Therefore, theta wave was used as fatigue feature in the following alarm device. The real-time alarm monitoring system based on the result has been developed, once the threshold was settled by using the data of the first ten minutes driving period. The developed system can detect driver fatigue and give alarm to indicate the onset of fatigue automatically.

  7.   Combination treatment of monosymptomatic enuresis nocturna with alarm and desmopressin

    DEFF Research Database (Denmark)

    Kamperis, Konstantinos; Hagstrøm, Søren; Rittig, Søren

    2006-01-01

      AIM To retrospectively evaluate the combination treatment with alarm and desmopressin in a population of children with monosymptomatic enuresis nocturna (MNE). MATERIAL AND METHODS 218 children with MNE (age 5-14y) treated in our outpatient clinics were investigated in the present study. All...... children had completed the diagnostic procedures of our center comprising 2-week home recordings, desmopressin titration, uroflowmetry and urinalysis. The latest ICCS standardization was used for characterizations. All children were treated with the enuresis alarm alone or in combination with desmopressin...... complete dryness. We found no differences with regards to age, gender, enuresis frequency, average and maximal voided volumes between children that achieved dryness with alarm or combination of alarm and desmopressin. However, children ending in combination treatment shared significantly higher nocturnal...

  8. Referential alarm calling behaviour in New World primates

    Directory of Open Access Journals (Sweden)

    Cristiane CÄSAR, Klaus ZUBERBÜHLER

    2012-10-01

    Full Text Available There is relatively good evidence that non-human primates can communicate about objects and events in their environment in ways that allow recipients to draw inferences about the nature of the event experienced by the signaller. In some species, there is also evidence that the basic semantic units are not individual calls, but call sequences and the combinations generated by them. These two findings are relevant to theories pertaining to the origins of human language because of the resemblances of these phenomena with linguistic reference and syntactic organisation. Until recently, however, most research efforts on the primate origins of human language have involved Old World species with comparatively few systematic studies on New World monkeys, which has prevented insights into the deeper phylogenetic roots and evolutionary origins of language-relevant capacities. To address this, we review the older primate literature and very recent evidence for functionally referential communication and call combinations in New World primates. Within the existing literature there is ample evidence in both Callitrichids and Cebids for acoustically distinct call variants given to external disturbances that are accompanied by distinct behavioural responses. A general pattern is that one call type is typically produced in response to a wide range of general disturbances, often on the ground but also including inter-group encounters, while another call type is produced in response to a much narrower range of aerial threats. This pattern is already described for Old World monkeys and Prosimians, suggesting an early evolutionary origin. Second, recent work with black-fronted titi monkeys has produced evidence for different alarm call sequences consisting of acoustically distinct call types. These sequences appear to encode several aspects of the predation event simultaneously, notably predator type and location. Since meaningful call sequences have already been

  9. Cutaneous factitia in elderly patients: alarm signal for psychiatric disorders

    Directory of Open Access Journals (Sweden)

    Chiriac A

    2014-03-01

    choose the proper therapy is mandatory for all these cases. Dermatologists and all physicians who take care of old patients must recognize the disorder in order to provide optimum care for this chronic condition. We emphasize therefore the importance of psychiatric evaluation and treatment to avoid the major risk of suicide. Skin lesions must be regarded as an alarm signal in critical cases, especially in senior people. Keywords: pathomimia, elderly, psychiatric disorders

  10. Campus Capability Plan

    Energy Technology Data Exchange (ETDEWEB)

    Adams, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Arsenlis, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bailey, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bergman, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brase, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brenner, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Camara, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Carlton, H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Cheng, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chrzanowski, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Colson, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); East, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Farrell, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ferranti, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gursahani, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hansen, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Helms, L. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hernandez, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jeffries, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Larson, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lu, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McNabb, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mercer, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Skeate, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sueksdorf, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zucca, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Le, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ancria, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Scott, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Leininger, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gagliardi, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gash, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bronson, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chung, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hobson, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Meeker, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sanchez, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zagar, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Quivey, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sommer, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Atherton, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-06-06

    Lawrence Livermore National Laboratory Campus Capability Plan for 2018-2028. Lawrence Livermore National Laboratory (LLNL) is one of three national laboratories that are part of the National Nuclear Security Administration. LLNL provides critical expertise to strengthen U.S. security through development and application of world-class science and technology that: Ensures the safety, reliability, and performance of the U.S. nuclear weapons stockpile; Promotes international nuclear safety and nonproliferation; Reduces global danger from weapons of mass destruction; Supports U.S. leadership in science and technology. Essential to the execution and continued advancement of these mission areas are responsive infrastructure capabilities. This report showcases each LLNL capability area and describes the mission, science, and technology efforts enabled by LLNL infrastructure, as well as future infrastructure plans.

  11. Technological Capability's Predictor Variables

    Directory of Open Access Journals (Sweden)

    Fernanda Maciel Reichert

    2011-03-01

    Full Text Available The aim of this study was to identify the factors that influence in configuration of the technological capability of companies in sectors with medium-low technological intensity. To achieve the goal proposed in this article a survey was carried out. Based on the framework developed by Lall (1992 which classifies firms in basic, intermediate and advanced level of technological capability; it was found that the predominant technological capability is intermediate, with 83.7% of respondent companies (plastics companies in Brazil. It is believed that the main contribution of this study is the finding that the dependent variable named “Technological Capability” can be explained at a rate of 65% by six variables: development of new processes; selection of the best equipment supplier; sales of internally developed new technology to third parties; design and manufacture of equipment; study of the work methods and perform inventory control; and improvement of product quality.

  12. Sandia QIS Capabilities.

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Sandia National Laboratories has developed a broad set of capabilities in quantum information science (QIS), including elements of quantum computing, quantum communications, and quantum sensing. The Sandia QIS program is built atop unique DOE investments at the laboratories, including the MESA microelectronics fabrication facility, the Center for Integrated Nanotechnologies (CINT) facilities (joint with LANL), the Ion Beam Laboratory, and ASC High Performance Computing (HPC) facilities. Sandia has invested $75 M of LDRD funding over 12 years to develop unique, differentiating capabilities that leverage these DOE infrastructure investments.

  13. Capability Handbook- offline metrology

    DEFF Research Database (Denmark)

    Islam, Aminul; Marhöfer, David Maximilian; Tosello, Guido

    This offline metrological capability handbook has been made in relation to HiMicro Task 3.3. The purpose of this document is to assess the metrological capability of the HiMicro partners and to gather the information of all available metrological instruments in the one single document. It provides...... a quick overview of what is possible today by the state of the art, what the HiMicro consortium can do and what metrological requirements we have concerning the HiMicro industrial demonstrators....

  14. Management Innovation Capabilities

    DEFF Research Database (Denmark)

    Harder, Mie

    Management innovation is the implementation of a new management practice, process, technique or structure that significantly alters the way the work of management is performed. This paper presents a typology categorizing management innovation along two dimensions; radicalness and complexity. Then......, the paper introduces the concept of management innovation capabilities which refers to the ability of a firm to purposefully create, extend and modify its managerial resource base to address rapidly changing environments. Drawing upon behavioral theory of the firm and the dynamic capabilities framework......, the paper proposes a model of the foundations of management innovation. Propositions and implications for future research are discussed....

  15. Habituation of adult sea lamprey repeatedly exposed to damage-released alarm and predator cues

    Science.gov (United States)

    Imre, Istvan; Di Rocco, Richard T.; Brown, Grant E.; Johnson, Nicholas

    2016-01-01

    Predation is an unforgiving selective pressure affecting the life history, morphology and behaviour of prey organisms. Selection should favour organisms that have the ability to correctly assess the information content of alarm cues. This study investigated whether adult sea lamprey Petromyzon marinus habituate to conspecific damage-released alarm cues (fresh and decayed sea lamprey extract), a heterospecific damage-released alarm cue (white sucker Catostomus commersoniiextract), predator cues (Northern water snake Nerodia sipedon washing, human saliva and 2-phenylethylamine hydrochloride (PEA HCl)) and a conspecific damage-released alarm cue and predator cue combination (fresh sea lamprey extract and human saliva) after they were pre-exposed 4 times or 8 times, respectively, to a given stimulus the previous night. Consistent with our prediction, adult sea lamprey maintained an avoidance response to conspecific damage-released alarm cues (fresh and decayed sea lamprey extract), a predator cue presented at high relative concentration (PEA HCl) and a conspecific damage-released alarm cue and predator cue combination (fresh sea lamprey extract plus human saliva), irrespective of previous exposure level. As expected, adult sea lamprey habituated to a sympatric heterospecific damage-released alarm cue (white sucker extract) and a predator cue presented at lower relative concentration (human saliva). Adult sea lamprey did not show any avoidance of the Northern water snake washing and the Amazon sailfin catfish extract (heterospecific control). This study suggests that conspecific damage-released alarm cues and PEA HCl present the best options as natural repellents in an integrated management program aimed at controlling the abundance of sea lamprey in the Laurentian Great Lakes.

  16. False Alarm Reduction in BSN-Based Cardiac Monitoring Using Signal Quality and Activity Type Information

    Directory of Open Access Journals (Sweden)

    Tanatorn Tanantong

    2015-02-01

    Full Text Available False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs, the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  17. Topological material layout in plates for vibration suppression and wave propagation control

    DEFF Research Database (Denmark)

    Larsen, Anders Astrup; Laksafoss, B.; Jensen, Jakob Søndergaard

    2009-01-01

    plate theory coupled with analytical sensitivity analysis using the adjoint method and an iterative design update procedure based on a mathematical programming tool. We demonstrate the capability of the method by designing bi-material plates that, when subjected to harmonic excitation, either......We propose a topological material layout method to design elastic plates with optimized properties for vibration suppression and guided transport of vibration energy. The gradient-based optimization algorithm is based on a finite element model of the plate vibrations obtained using the Mindlin...... effectively suppress the overall vibration level or alternatively transport energy in predefined paths in the plates, including the realization of a ring wave device....

  18. Capabilities for Intercultural Dialogue

    Science.gov (United States)

    Crosbie, Veronica

    2014-01-01

    The capabilities approach offers a valuable analytical lens for exploring the challenge and complexity of intercultural dialogue in contemporary settings. The central tenets of the approach, developed by Amartya Sen and Martha Nussbaum, involve a set of humanistic goals including the recognition that development is a process whereby people's…

  19. a Capability approach

    African Journals Online (AJOL)

    efforts towards gender equality in education as a means of achieving social justice. Over the years .... who, in exploring the idea of capabilities in support of the intrinsic importance of gender equality in education, came up ... Firstly, personal conversion factors (e.g. metabolism, physical condition, sex, gender, reading skills ...

  20. The Capability Approach

    NARCIS (Netherlands)

    I.A.M. Robeyns (Ingrid)

    2011-01-01

    textabstract In its most general description, the capability approach is a flexible and multi-purpose normative framework, rather than a precise theory of well-being, freedom or justice. At its core are two normative claims: first, the claim that the freedom to achieve well-being is of primary

  1. Building Service Provider Capabilities

    DEFF Research Database (Denmark)

    Brandl, Kristin; Jaura, Manya; Ørberg Jensen, Peter D.

    In this paper we study whether and how the interaction between clients and the service providers contributes to the development of capabilities in service provider firms. In situations where such a contribution occurs, we analyze how different types of activities in the production process...

  2. a Capability approach

    African Journals Online (AJOL)

    focus on personal and socio-environmental conversion factors that transform resources into functionings, and on the whole social and institutional context that affects the conversion factors and also the capability set directly (Sen, 2009; Unterhalter, 2007 and Robeyns, 2007). Applying this to the SMTs learning and teaching ...

  3. Visual Absorption Capability

    Science.gov (United States)

    Lee Anderson; Jerry Mosier; Geoffrey Chandler

    1979-01-01

    Visual absorption capability (VAC) is a tool to assess a landscape's susceptibility to visual change caused by man's activities. This paper explores different descriptive approaches to VAC and addresses in depth the development of the VAC process used on the Klamath National Forest. Four biophysical factors were selected to assess VAC for the lands within the...

  4. Capabilities and Special Needs

    DEFF Research Database (Denmark)

    Kjeldsen, Christian Christrup

    into international consideration in relation to the implementation of the UN convention on the rights of persons with disabilities. As for the theoretical basis, the research makes use of the sociological open-ended and relational concepts of Pierre Bourdieu and the normative yardstick of the Capability Approach...

  5. Capabilities Composition (Briefing Charts)

    Science.gov (United States)

    2009-04-22

    and support , , processes (including ITIL v3) • Understanding of Governance is still evolving Engineering Acquisition and Operational Governance...L – Logistics • NC – Net-Centric • CPM – Capability Portfolio Management • ITIL v3 – Information Technology • ONR – Office of Naval Research

  6. Animal Communications Through Seismic Vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Peggy (University of Tulsa)

    2001-05-02

    Substrate vibration has been important to animals as a channel of communication for millions of years, but our literature on vibration in this context of biologically relevant information is only decades old. The jaw mechanism of the earliest land vertebrates allowed them to perceive substrate vibrations as their heads lay on the ground long before airborne sounds could be heard. Although the exact mechanism of vibration production and the precise nature of the wave produced are not always understood, recent development of affordable instrumentation to detect and measure vibrations has allowed researchers to answer increasingly sophisticated questions about how animals send and receive vibration signals. We now know that vibration provides information used in predator defense, prey detection, recruitment to food, mate choice, intrasexual competition, and maternal/brood social interactions in a variety of insect orders, spiders, crabs, scorpions, chameleons, frogs, golden moles, mole rats, kangaroos rats, wallabies, elephants and bison.

  7. Capitalizing on capabilities.

    Science.gov (United States)

    Ulrich, Dave; Smallwood, Norm

    2004-06-01

    By making the most of organizational capabilities--employees' collective skills and fields of expertise--you can dramatically improve your company's market value. Although there is no magic list of proficiencies that every organization needs in order to succeed, the authors identify 11 intangible assets that well-managed companies tend to have: talent, speed, shared mind-set and coherent brand identity, accountability, collaboration, learning, leadership, customer connectivity, strategic unity, innovation, and efficiency. Such companies typically excel in only three of these capabilities while maintaining industry parity in the other areas. Organizations that fall below the norm in any of the 11 are likely candidates for dysfunction and competitive disadvantage. So you can determine how your company fares in these categories (or others, if the generic list doesn't suit your needs), the authors explain how to conduct a "capabilities audit," describing in particular the experiences and findings of two companies that recently performed such audits. In addition to highlighting which intangible assets are most important given the organization's history and strategy, this exercise will gauge how well your company delivers on its capabilities and will guide you in developing an action plan for improvement. A capabilities audit can work for an entire organization, a business unit, or a region--indeed, for any part of a company that has a strategy to generate financial or customer-related results. It enables executives to assess overall company strengths and weaknesses, senior leaders to define strategy, midlevel managers to execute strategy, and frontline leaders to achieve tactical results. In short, it helps turn intangible assets into concrete strengths.

  8. The challenge of localizing vehicle backup alarms: Effects of passive and electronic hearing protectors, ambient noise level, and backup alarm spectral content

    Directory of Open Access Journals (Sweden)

    Khaled A Alali

    2011-01-01

    Full Text Available A human factors experiment employed a hemi-anechoic sound field in which listeners were required to localize a vehicular backup alarm warning signal (both a standard and a frequency-augmented alarm in 360-degrees azimuth in pink noise of 60 dBA and 90 dBA. Measures of localization performance included: (1 percentage correct localization, (2 percentage of right--left localization errors, (3 percentage of front-rear localization errors, and (4 localization absolute deviation in degrees from the alarm′s actual location. In summary, the data demonstrated that, with some exceptions, normal hearing listeners′ ability to localize the backup alarm in 360-degrees azimuth did not improve when wearing augmented hearing protectors (including dichotic sound transmission earmuffs, flat attenuation earplugs, and level-dependent earplugs as compared to when wearing conventional passive earmuffs or earplugs of the foam or flanged types. Exceptions were that in the 90 dBA pink noise, the flat attenuation earplug yielded significantly better accuracy than the polyurethane foam earplug and both the dichotic and the custom-made diotic electronic sound transmission earmuffs. However, the flat attenuation earplug showed no benefit over the standard pre-molded earplug, the arc earplug, and the passive earmuff. Confusions of front-rear alarm directions were most significant in the 90 dBA noise condition, wherein two types of triple-flanged earplugs exhibited significantly fewer front-rear confusions than either of the electronic muffs. On all measures, the diotic sound transmission earmuff resulted in the poorest localization of any of the protectors due to the fact that its single-microphone design did not enable interaural cues to be heard. Localization was consistently more degraded in the 90 dBA pink noise as compared with the relatively quiet condition of the 60 dBA pink noise. A frequency-augmented backup alarm, which incorporated 400 Hz and 4000 Hz components

  9. Vibration Attenuation of Plate Using Multiple Vibration Absorbers

    Directory of Open Access Journals (Sweden)

    Zaman Izzuddin

    2014-07-01

    Full Text Available Vibrations are undesired phenomenon and it can cause harm, distress and unsettling influence to the systems or structures, for example, aircraft, automobile, machinery and building. One of the approach to limit this vibration by introducing passive vibration absorber attached to the structure. In this paper, the adequacy of utilizing passive vibration absorbers are investigated. The vibration absorber system is designed to minimize the vibration of a thin plate fixed along edges. The plate’s vibration characteristics, such as, natural frequency and mode shape are determined using three techniques: theoretical equations, finite element (FE analysis and experiment. The results demonstrate that the first four natural frequencies of fixed-fixed ends plate are 48, 121, 193 and 242 Hz, and these results are corroborated well with theoretical, FE simulation and experiment. The experiment work is further carried out with attached single and multiple vibration absorbers onto plate by tuning the absorber’s frequency to match with the excitation frequency. The outcomes depict that multiple vibration absorbers are more viable in lessening the global structural vibration.

  10. Good vibrations. [Hydraulic turbines

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, P.

    1994-07-01

    The latest developments in the Voith Turbine Control and Automation System (VTLS), which couples digital control technology to hydropower plant equipment, are described. Prominent among these is the vibration diagnostics module for hydraulic turbines. It provides machine-specific diagnostic logic for a vibration monitoring and analysis system. Of the two other VTLS modules described, the operation module optimizes the control of a power plant with three or more turbines by considering the individual properties of each in turn, recommending which should be run, and how, in order to partition the load for a required power output. The cavitation module is a diagnostic system which enables the limits of operation of the turbines to be extended to bands just outside those determined by cavitation calculations. (3 figures). (UK)

  11. Vibrational stability of graphene

    Directory of Open Access Journals (Sweden)

    Yangfan Hu

    2013-05-01

    Full Text Available The mechanical stability of graphene as temperature rises is analyzed based on three different self-consistent phonon (SCP models. Compared with three-dimensional (3-D materials, the critical temperature Ti at which instability occurs for graphene is much closer to its melting temperature Tm obtained from Monte Carlo simulation (Ti ≃ 2Tm, K. V. Zakharchenko, A. Fasolino, J. H. Los, and M. I. Katsnelson, J. Phys. Condens. Matter 23, 202202. This suggests that thermal vibration plays a significant role in melting of graphene while melting for 3-D materials is often dominated by topologic defects. This peculiar property of graphene derives from its high structural anisotropy, which is characterized by the vibrational anisotropic coefficient (VAC, defined upon its Lindermann ratios in different directions. For any carbon based material with a graphene-like structure, the VAC value must be smaller than 5.4 to maintain its stability. It is also found that the high VAC value of graphene is responsible for its negative thermal expansion coefficient at low temperature range. We believe that the VAC can be regarded as a new criterion concerning the vibrational stability of any low-dimensional (low-D materials.

  12. Building Server Capabilities

    DEFF Research Database (Denmark)

    Adeyemi, Oluseyi

    2013-01-01

    Many western companies have moved part of their operations to China in order to take advantage of cheap resources and/or to gain access to a high potential market. Depending on motive, offshore facilities usually start either as “sales-only” of products exported by headquarters or “production......-only”, exporting parts and components back to headquarter for sales in the home country. In the course of time, the role of offshore subsidiaries in a company’s operations network tends to change and, with that, the capabilities, of the subsidiaries. Focusing on Danish subsidiaries in China, the objective...... of this project is to identify and explain trajectories of offshore subsidiary capability development. Given the nature of this objective the chief methodology is longitudinal, partly retrospective, partly real-time, case studies....

  13. Metrology Measurement Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, L.M.

    2003-11-12

    This document contains descriptions of Federal Manufacturing & Technologies (FM&T) Metrology capabilities, traceability flow charts, and the measurement uncertainty of each measurement capability. Metrology provides NIST traceable precision measurements or equipment calibration for a wide variety of parameters, ranges, and state-of-the-art uncertainties. Metrology laboratories conform to the requirements of the Department of Energy Development and Production Manual Chapter 8.4, ANSI/ISO/IEC ANSI/ISO/IEC 17025:2000, and ANSI/NCSL Z540-1 (equivalent to ISO Guide 25). FM&T Metrology laboratories are accredited by NVLAP for the parameters, ranges, and uncertainties listed in the specific scope of accreditation under NVLAP Lab code 200108-0. See the Internet at http://ts.nist.gov/ts/htdocs/210/214/scopes/2001080.pdf. These parameters are summarized in the table at the bottom of this introduction.

  14. Wireless alerting system using vibration for vehicles dashboard

    Science.gov (United States)

    Raj, Sweta; Rai, Shweta; Magaramagara, Wilbert; Sivacoumar, R.

    2017-11-01

    This paper aims at improving the engine life of any vehicle through a continuous measurement and monitoring of vital engine operational parameters and providing an effective alerting to drivers for any abnormality. Vehicles currently are using audio and visible alerting signals through alarms and light as a warning to the driver but these are not effective in noisy environments and during daylight. Through the use of the sense of feeling a driver can be alerted effectively. The need to no other vehicle parameter needs to be aided through the mobile display (phone).Thus a system is designed and implements to measure engine temperature, RPM, Oil level and Coolant level using appropriate sensors and a wireless communication (Bluetooth) is established to actuate a portable vibration control device and to read the different vehicle sensor readings through an android application for display and diagnosis.

  15. Assessment of Gear Damage Monitoring Techniques Using Vibration Measurements

    Science.gov (United States)

    Wang, Wilson Q.; Ismail, Fathy; Farid Golnaraghi, M.

    2001-09-01

    Each gear damage monitoring technique has its merits and limitations. This paper experimentally investigates the sensitivity and robustness of the currently well-accepted techniques: phase and amplitude demodulation, beta kurtosis and wavelet transform. Four gear test cases were used: healthy gears, cracked, filed and chipped gears. The vibration signal was measured on the gearbox housing and processed, online, under three filtering conditions: general signal average, overall residual and dominant meshing frequency residual. Test results show that beta kurtosis is a very reliable time-domain diagnostic technique. Phase modulation is very sensitive to gear imperfections, but other information should be used to confirm its diagnostic results. Continuous wavelet transform provides a good visual inspection especially when residual signals are used. The diagnosis based only on dominant meshing frequency residual, however, should not be used independently for gear health condition monitoring, it may give false alarms.

  16. Group Capability Model

    Science.gov (United States)

    Olejarski, Michael; Appleton, Amy; Deltorchio, Stephen

    2009-01-01

    The Group Capability Model (GCM) is a software tool that allows an organization, from first line management to senior executive, to monitor and track the health (capability) of various groups in performing their contractual obligations. GCM calculates a Group Capability Index (GCI) by comparing actual head counts, certifications, and/or skills within a group. The model can also be used to simulate the effects of employee usage, training, and attrition on the GCI. A universal tool and common method was required due to the high risk of losing skills necessary to complete the Space Shuttle Program and meet the needs of the Constellation Program. During this transition from one space vehicle to another, the uncertainty among the critical skilled workforce is high and attrition has the potential to be unmanageable. GCM allows managers to establish requirements for their group in the form of head counts, certification requirements, or skills requirements. GCM then calculates a Group Capability Index (GCI), where a score of 1 indicates that the group is at the appropriate level; anything less than 1 indicates a potential for improvement. This shows the health of a group, both currently and over time. GCM accepts as input head count, certification needs, critical needs, competency needs, and competency critical needs. In addition, team members are categorized by years of experience, percentage of contribution, ex-members and their skills, availability, function, and in-work requirements. Outputs are several reports, including actual vs. required head count, actual vs. required certificates, CGI change over time (by month), and more. The program stores historical data for summary and historical reporting, which is done via an Excel spreadsheet that is color-coded to show health statistics at a glance. GCM has provided the Shuttle Ground Processing team with a quantifiable, repeatable approach to assessing and managing the skills in their organization. They now have a common

  17. [Implementation of an automatic alarms system for early detection of patients with severe sepsis].

    Science.gov (United States)

    Ferreras, José María; Judez, Diego; Tirado, Gabriel; Aspiroz, Carmen; Martínez-Álvarez, Rosa; Dorado, Paloma; Ezpeleta, Ana; Marrón, Rafael; Gargallo, Begoña; Herranz, Clara

    2015-10-01

    The objective of this study was to assess the usefulness of a software tool integrated into the medical electronic history at the time of emergency triage. The aim was the early detection of patients with severe sepsis, and the potential impact of this software tool on reducing the mortality rate in patients treated. The study consisted of two comparative samples. Patient selection was performed retrospectively into two groups using ICD-9 codes from the hospital and emergency department discharge reports. The codes were 038.9, 995.9 and 995.92 for sepsis, and 785.52 for severe sepsis and septic shock. The sample called «alarms» consisted of patients studied after implementing the sepsis alarm system in the Emergency Department computer system. There were two types of alarms, a serious one and an alert one depending on the on vital signs defined. The historical sample called «no alarms» consisted of patients seen in the Emergency Department during the year before the introduction of the alarm system. The compliance rate of the sepsis treatment package was higher in the «alarms» sample, compared to the sample without alarms, with blood cultures, 96.3% versus 80.9% (Psepsis allows acting earlier, better compliance with basic measures, and a reduction in hospital stay and mortality. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  18. Communication strategies and timeliness of response to life critical telemetry alarms.

    Science.gov (United States)

    Bonzheim, Kimberly A; Gebara, Rani I; O'Hare, Bridget M; Ellis, R Darin; Brand, Monique A; Balar, Salil D; Stockman, Rita; Sciberras, Annette M; Haines, David E

    2011-05-01

    A centralized electrocardiogram telemetry monitoring system (TMS) facilitates early identification of critical arrhythmias and acute medical decompensation. Timely intervention can only be performed if abnormalities are communicated rapidly to the direct caregiver. The study objectives were to measure effectiveness of bi-directional voice communication badges versus one-way alphanumeric pagers for telemetry alarm response and communication loop closure. A sequential observational pilot study of nursing response to TMS alarms compared communication technologies on four nursing units in a 1,061 bed tertiary care hospital with 264 TMS channels of telemetry over a 2-year period. Subsequently, the communication technologies were compared in a randomized fashion on a 68-bed progressive cardiac care unit. Caregivers were blinded to the protocol. All alarm responses were recorded during two periods using either pagers or voice communication devices. Alarm response time and closure of the communication loop were analyzed in a blinded fashion. The direct communication functionality of the badge significantly shortened the time to first contact, time to completion, and rate of closure of the communication loop in both the pilot and study phases. Median time to first contact with the communication badge was 0.5  min, compared to 1.6  min with pager communication (p Communication loop closure was achieved in 100% of clinical alarms using the badge versus 19% with the pager (p Communication badge technology reduced alarm time to first contact and completion as well as facilitated communication loop closures. Immediate two-way communication significantly impacted practice, alarm management, and resulted in faster bedside care.

  19. Nitric Acid Revamp and Upgrading of the Alarm & Protection Safety System at Petrokemija, Croatia

    Directory of Open Access Journals (Sweden)

    Hoško, I.

    2012-04-01

    Full Text Available Every industrial production, particularly chemical processing, demands special attention in conducting the technological process with regard to the security requirements. For this reason, production processes should be continuously monitored by means of control and alarm safety instrumented systems. In the production of nitric acid at Petrokemija d. d., the original alarm safety system was designed as a combination of an electrical relay safety system and transistorized alarm module system. In order to increase safety requirements and modernize the technological process of nitric acid production, revamping and upgrading of the existing alarm safety system was initiated with a new microprocessor system. The newly derived alarm safety system, Simatic PCS 7, links the function of "classically" distributed control (DCS and logical systems in a common hardware and software platform with integrated engineering tools and operator interface to meet the minimum safety standards with safety integrity level 2 (SIL2 up to level 3 (SIL3, according to IEC 61508 and IEC 61511. This professional paper demonstrates the methodology of upgrading the logic of the alarm safety system in the production of nitric acid in the form of a logical diagram, which was the basis for a further step in its design and construction. Based on the mentioned logical diagram and defined security requirements, the project was implemented in three phases: analysis and testing, installation of the safety equipment and system, and commissioning. Developed also was a verification system of all safety conditions, which could be applied to other facilities for production of nitric acid. With the revamped and upgraded interlock alarm safety system, a new and improved safety boundary in the production of nitric acid was set, which created the foundation for further improvement of the production process in terms of improved analysis.

  20. Piezoelectric Vibration Damping Study for Rotating Composite Fan Blades

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Choi, Benjamin B.; Provenza, Andrew J.; Kray, Nicholas

    2012-01-01

    Resonant vibrations of aircraft engine blades cause blade fatigue problems in engines, which can lead to thicker and aerodynamically lower performing blade designs, increasing engine weight, fuel burn, and maintenance costs. In order to mitigate undesirable blade vibration levels, active piezoelectric vibration control has been investigated, potentially enabling thinner blade designs for higher performing blades and minimizing blade fatigue problems. While the piezoelectric damping idea has been investigated by other researchers over the years, very little study has been done including rotational effects. The present study attempts to fill this void. The particular objectives of this study were: (a) to develop and analyze a multiphysics piezoelectric finite element composite blade model for harmonic forced vibration response analysis coupled with a tuned RLC circuit for rotating engine blade conditions, (b) to validate a numerical model with experimental test data, and (c) to achieve a cost-effective numerical modeling capability which enables simulation of rotating blades within the NASA Glenn Research Center (GRC) Dynamic Spin Rig Facility. A numerical and experimental study for rotating piezoelectric composite subscale fan blades was performed. It was also proved that the proposed numerical method is feasible and effective when applied to the rotating blade base excitation model. The experimental test and multiphysics finite element modeling technique described in this paper show that piezoelectric vibration damping can significantly reduce vibrations of aircraft engine composite fan blades.

  1. Seventh international conference on time-resolved vibrational spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, R.B.; Martinez, M.A.D.; Shreve, A.; Woodruff, W.H. [comps.

    1997-04-01

    The International Conference on Time-Resolved Vibrational Spectroscopy (TRVS) is widely recognized as the major international forum for the discussion of advances in this rapidly growing field. The 1995 conference was the seventh in a series that began at Lake Placid, New York, 1982. Santa Fe, New Mexico, was the site of the Seventh International Conference on Time-Resolved Vibrational Spectroscopy, held from June 11 to 16, 1995. TRVS-7 was attended by 157 participants from 16 countries and 85 institutions, and research ranging across the full breadth of the field of time-resolved vibrational spectroscopy was presented. Advances in both experimental capabilities for time-resolved vibrational measurements and in theoretical descriptions of time-resolved vibrational methods continue to occur, and several sessions of the conference were devoted to discussion of these advances and the associated new directions in TRVS. Continuing the interdisciplinary tradition of the TRVS meetings, applications of time-resolved vibrational methods to problems in physics, biology, materials science, and chemistry comprised a large portion of the papers presented at the conference.

  2. The nature of alarm communication in Constrictotermes cyphergaster (Blattodea: Termitoidea: Termitidae): the integration of chemical and vibroacoustic signals.

    Science.gov (United States)

    Cristaldo, Paulo F; Jandák, Vojtĕch; Kutalová, Kateřina; Rodrigues, Vinícius B; Brothánek, Marek; Jiříček, Ondřej; DeSouza, Og; Šobotník, Jan

    2015-11-04

    Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae), confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S)-α-pinene and myrcene, along with a minor component, (E)-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards) resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant) increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through vibratory signals, and

  3. The nature of alarm communication in Constrictotermes cyphergaster (Blattodea: Termitoidea: Termitidae: the integration of chemical and vibroacoustic signals

    Directory of Open Access Journals (Sweden)

    Paulo F. Cristaldo

    2015-12-01

    Full Text Available Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae, confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S-α-pinene and myrcene, along with a minor component, (E-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through

  4. The nature of alarm communication in Constrictotermes cyphergaster (Blattodea: Termitoidea: Termitidae): the integration of chemical and vibroacoustic signals

    Science.gov (United States)

    Cristaldo, Paulo F.; Jandák, Vojtĕch; Kutalová, Kateřina; Rodrigues, Vinícius B.; Brothánek, Marek; Jiříček, Ondřej; DeSouza, Og; Šobotník, Jan

    2015-01-01

    ABSTRACT Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae), confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S)-α-pinene and myrcene, along with a minor component, (E)-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards) resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant) increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through vibratory

  5. VIBRATION ISOLATION SYSTEM PROBABILITY ANALYSIS

    Directory of Open Access Journals (Sweden)

    Smirnov Vladimir Alexandrovich

    2012-10-01

    Full Text Available The article deals with the probability analysis for a vibration isolation system of high-precision equipment, which is extremely sensitive to low-frequency oscillations even of submicron amplitude. The external sources of low-frequency vibrations may include the natural city background or internal low-frequency sources inside buildings (pedestrian activity, HVAC. Taking Gauss distribution into account, the author estimates the probability of the relative displacement of the isolated mass being still lower than the vibration criteria. This problem is being solved in the three dimensional space, evolved by the system parameters, including damping and natural frequency. According to this probability distribution, the chance of exceeding the vibration criteria for a vibration isolation system is evaluated. Optimal system parameters - damping and natural frequency - are being developed, thus the possibility of exceeding vibration criteria VC-E and VC-D is assumed to be less than 0.04.

  6. Random vibrations theory and practice

    CERN Document Server

    Wirsching, Paul H; Ortiz, Keith

    1995-01-01

    Random Vibrations: Theory and Practice covers the theory and analysis of mechanical and structural systems undergoing random oscillations due to any number of phenomena— from engine noise, turbulent flow, and acoustic noise to wind, ocean waves, earthquakes, and rough pavement. For systems operating in such environments, a random vibration analysis is essential to the safety and reliability of the system. By far the most comprehensive text available on random vibrations, Random Vibrations: Theory and Practice is designed for readers who are new to the subject as well as those who are familiar with the fundamentals and wish to study a particular topic or use the text as an authoritative reference. It is divided into three major sections: fundamental background, random vibration development and applications to design, and random signal analysis. Introductory chapters cover topics in probability, statistics, and random processes that prepare the reader for the development of the theory of random vibrations a...

  7. Levels of alarm thresholds of meningitis outbreaks in Hamadan Province, west of Iran.

    Science.gov (United States)

    Faryadres, Mohammad; Karami, Manoochehr; Moghimbeigi, Abbas; Esmailnasab, Nader; Pazhouhi, Khabat

    2015-01-01

    Few studies have focused on syndromic data to determine levels of alarm thresholds to detection of meningitis outbreaks. The purpose of this study was to determine threshold levels of meningitis outbreak in Hamadan Province, west of Iran. Data on both confirmed and suspected cases of meningitis (fever and neurological symptom) form 21 March 2010 to 20 March 2012 were used in Hamadan Province, Iran. Alarm threshold levels of meningitis outbreak were determined using four different methods including absolute values or standard method, relative increase, statistical cutoff points and upper control limit of exponentially weighted moving average (EWMA) algorithm. Among 723 reported cases, 41 were diagnosed to have meningitis. Standard level of alarm thresholds for meningitis outbreak was determined as incidence of 5/100000 persons. Increasing 1.5 to two times in reported cases of suspected meningitis per week was known as the threshold levels according to relative increase method. An occurrence four cases of suspected meningitis per week that equals to 90th percentile was chosen as alarm thresholds by statistical cut off point method. The corresponding value according to EWMA algorithm was 2.57 i.e. three cases. Policy makers and staff of syndromic surveillance systems are highly recommended to apply the above different methods to determine the levels of alarm threshold.

  8. Alarm pheromone that aggravates stress-induced hyperthermia is soluble in water.

    Science.gov (United States)

    Kiyokawa, Yasushi; Kikusui, Takefumi; Takeuchi, Yukari; Mori, Yuji

    2005-07-01

    We previously reported that stressed male Wistar rats released alarm pheromone from the perianal region, which aggravated stress-induced hyperthermia and increased Fos expression in the mitral/tufted cell layer of the accessory olfactory bulb in recipient rats. In this study, we attempted to obtain this pheromone in water using these responses as bioassay parameters. Water droplets were collected from the ceiling of a box in which no animal was placed, or from a box in which an anesthetized donor rat was given electrical stimulation to either the neck or perianal regions in order to induce neck odor or alarm pheromone release, respectively. Then we placed one of the three kinds of water-containing filter papers on the wall of a recipient's home cage and observed heart rate, body temperature and behavioral responses, as well as Fos expression in the main and accessory olfactory bulbs of the recipient. The water collected from the box containing the alarm pheromone was found to generate a reproduction of all of the responses seen in the animal that had been directly exposed to alarm pheromone in our previous studies. These results suggest that the alarm pheromone is soluble in water.

  9. Monitoring techniques and alarm procedures for CMS services and sites in WLCG

    Energy Technology Data Exchange (ETDEWEB)

    Molina-Perez, J. [UC, San Diego; Bonacorsi, D. [Bologna U.; Gutsche, O. [Fermilab; Sciaba, A. [CERN; Flix, J. [Madrid, CIEMAT; Kreuzer, P. [CERN; Fajardo, E. [Andes U., Bogota; Boccali, T. [INFN, Pisa; Klute, M. [MIT; Gomes, D. [Rio de Janeiro State U.; Kaselis, R. [Vilnius U.; Du, R. [Beijing, Inst. High Energy Phys.; Magini, N. [CERN; Butenas, I. [Vilnius U.; Wang, W. [Beijing, Inst. High Energy Phys.

    2012-01-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS, the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.

  10. SMS Based Car Alarm System Utilizing AT89S52 Microcontroller

    Directory of Open Access Journals (Sweden)

    Balza Achmad

    2008-04-01

    Full Text Available This study aims to design a car alarm system. The system is designed to activating an alarm (danger signal and sends SMS messages to the HP owners of the car when sensors on the car alarm are active. The hardware of car alarm system use AT89S52 microcontroller based on SMS in this research, consists of a series of 4 main parts, namely the minimum system microcontroller circuits, power supply, serial communications, and input/output. In an SMS text sent and received from the cell phone to the SMS Center flows in the form of PDU (Protocol Data Unit. The SMS format is divided into several segments of data that each segment has a specific purpose. Segments are: SMS center number, destination number, bytes SMS settings for this and most important is the content of SMS messages that have been modified in the form of UPE. The instructions AT Command is required to send or upload SMS data to mobile phone and send SMS data. The results showed that the performance of the alarm system designed is work properly.

  11. Supporting attention allocation in multitask environments: effects of likelihood alarm systems on trust, behavior, and performance.

    Science.gov (United States)

    Wiczorek, Rebecca; Manzey, Dietrich

    2014-11-01

    The aim of the current study was to investigate potential benefits of likelihood alarm systems (LASs) over binary alarm systems (BASs) in a multitask environment. Several problems are associated with the use of BASs, because most of them generate high numbers of false alarms. Operators lose trust in the systems and ignore alarms or cross-check all of them when other information is available. The first behavior harms safety, whereas the latter one reduces productivity. LASs represent an alternative, which is supposed to improve operators' attention allocation. We investigated LASs and BASs in a dual-task paradigm with and without the possibility to cross-check alerts with raw data information. Participants' trust in the system, their behavior, and their performance in the alert and the concurrent task were assessed. Reported trust, compliance with alarms, and performance in the alert and the concurrent task were higher for the LAS than for the BAS. The cross-check option led to an increase in alert task performance for both systems and a decrease in concurrent task performance for the BAS, which did not occur in the LAS condition. LASs improve participants' attention allocation between two different tasks and therefore lead to an increase in alert task and concurrent task performance. The performance maximum is achieved when LAS is combined with a cross-check option for validating alerts with additional information. The use of LASs instead of BASs in safety-related multitask environments has the potential to increase safety and productivity likewise.

  12. "Alarm-corrected" ergonomic armrest use could improve learning curves of novices on robotic simulator.

    Science.gov (United States)

    Yang, Kun; Perez, Manuela; Hossu, Gabriela; Hubert, Nicolas; Perrenot, Cyril; Hubert, Jacques

    2017-01-01

    In robotic surgery, the professional ergonomic habit of using an armrest reduces operator fatigue and increases the precision of motion. We designed and validated a pressure surveillance system (PSS) based on force sensors to investigate armrest use. The objective was to evaluate whether adding an alarm to the PSS system could shorten ergonomic training and improve performance. Twenty robot and simulator-naïve participants were recruited and randomized in two groups (A and B). The PSS was installed on a robotic simulator, the dV-Trainer, to detect contact with the armrest. The Group A members completed three tasks on the dV-Trainer without the alarm, making 15 attempts at each task. The Group B members practiced the first two tasks with the alarm and then completed the final tasks without the alarm. The simulator provided an overall score reflecting the trainees' performance. We used the new concept of an "armrest load" score to describe the ergonomic habit of using the armrest. Group B had a significantly higher performance score (p ergonomic errors and accelerated professional ergonomic habit acquisition. The combination of the PSS and alarm is effective in significantly shortening the learning curve in the robotic training process.

  13. The sound of danger: threat sensitivity to predator vocalizations, alarm calls, and novelty in gulls.

    Directory of Open Access Journals (Sweden)

    Sarah A MacLean

    Full Text Available The threat sensitivity hypothesis predicts that organisms will evaluate the relative danger of and respond differentially to varying degrees of predation threat. Doing so allows potential prey to balance the costs and benefits of anti-predator behaviors. Threat sensitivity has undergone limited testing in the auditory modality, and the relative threat level of auditory cues from different sources is difficult to infer across populations when variables such as background risk and experience are not properly controlled. We experimentally exposed a single population of two sympatric gull species to auditory stimuli representing a range of potential threats in order to compare the relative threat of heterospecific alarm calls, conspecific alarms calls, predator vocalizations, and novel auditory cues. Gulls were able to discriminate among a diverse set of threat indicators and respond in a graded manner commensurate with the level of threat. Vocalizations of two potential predators, the human voice and bald eagle call, differed in their threat level compared to each other and to alarm calls. Conspecific alarm calls were more threatening than heterospecfic alarm calls to the larger great black-backed gull, but the smaller herring gull weighed both equally. A novel cue elicited a response intermediate between known threats and a known non-threat in herring gulls, but not great black-backed gulls. Our results show that the relative threat level of auditory cues from different sources is highly species-dependent, and that caution should be exercised when comparing graded and threshold threat sensitive responses.

  14. ISOPHOT - Capabilities and performance

    DEFF Research Database (Denmark)

    Lemke, D.; Klaas, U.; Abolins, J.

    1996-01-01

    ISOPHOT covers the largest wavelength range on ISO from 2.5 to 240 mu m. Its scientific capabilities include multi filter and multi-aperture photometry, polarimetry, imaging and spectrophotometry. All modes can optionally include a focal plane chopper. The backbone of the photometric calibration...... operating the instrument in space are continuously being implemented in the standard data reduction software packages available to every observer. Particular strengths of the instrument include the detectability of very cold sources, high resolution mapping and fast spectrophotometry. The far infrared...

  15. Practical design of a nonlinear tuned vibration absorber

    DEFF Research Database (Denmark)

    Grappasonni, C.; Habib, G.; Detroux, T.

    2014-01-01

    The aim of the paper is to develop a new nonlinear tuned vibration absorber (NLTVA) capable of mitigating the vibrations of nonlinear systems which are known to exhibit frequency-energy-dependent oscillations. A nonlinear generalization of Den Hartog's equal-peak method is proposed to ensure equal...... peaks in the nonlinear frequency response for a large range of forcing amplitudes. An analytical tuning procedure is developed and provides the load-deflection characteristic of the NLTVA. Based on this prescribed relation, the NLTVA design is performed by two different approaches, namely thanks to (i...

  16. Fault detection of a spur gear using vibration signal with multivariable statistical parameters

    Directory of Open Access Journals (Sweden)

    Songpon Klinchaeam

    2014-10-01

    Full Text Available This paper presents a condition monitoring technique of a spur gear fault detection using vibration signal analysis based on time domain. Vibration signals were acquired from gearboxes and used to simulate various faults on spur gear tooth. In this study, vibration signals were applied to monitor a normal and various fault conditions of a spur gear such as normal, scuffing defect, crack defect and broken tooth. The statistical parameters of vibration signal were used to compare and evaluate the value of fault condition. This technique can be applied to set alarm limit of the signal condition based on statistical parameter such as variance, kurtosis, rms and crest factor. These parameters can be used to set as a boundary decision of signal condition. From the results, the vibration signal analysis with single statistical parameter is unclear to predict fault of the spur gears. The using at least two statistical parameters can be clearly used to separate in every case of fault detection. The boundary decision of statistical parameter with the 99.7% certainty ( 3   from 300 referenced dataset and detected the testing condition with 99.7% ( 3   accuracy and had an error of less than 0.3 % using 50 testing dataset.

  17. Chaotic vortex induced vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, J.; Sheridan, J. [Fluids Laboratory for Aeronautical and Industrial Research (FLAIR), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Victoria 3800 (Australia); Leontini, J. S. [Department of Mechanical and Product Design Engineering, Swinburne University of Technology, Hawthorn, Victoria 3122 (Australia); Lo Jacono, D. [Institut de Mécanique des Fluides de Toulouse (IMFT), CNRS, UPS and Université de Toulouse, 31400 Toulouse (France)

    2014-12-15

    This study investigates the nature of the dynamic response of an elastically mounted cylinder immersed in a free stream. A novel method is utilized, where the motion of the body during a free vibration experiment is accurately recorded, and then a second experiment is conducted where the cylinder is externally forced to follow this recorded trajectory. Generally, the flow response during both experiments is identical. However, particular regimes exist where the flow response is significantly different. This is taken as evidence of chaos in these regimes.

  18. Lattice Vibrations in Chlorobenzenes:

    DEFF Research Database (Denmark)

    Reynolds, P. A.; Kjems, Jørgen; White, J. W.

    1974-01-01

    Lattice vibrational dispersion curves for the ``intermolecular'' modes in the triclinic, one molecule per unit cell β phase of p‐C6D4Cl2 and p‐C6H4Cl2 have been obtained by inelastic neutron scattering. The deuterated sample was investigated at 295 and at 90°K and a linear extrapolation to 0°K...... was applied in order to correct for anharmonic effects. Calculations based on the atom‐atom model for van der Waals' interaction and on general potential parameters for the aromatic compounds agree reasonably well with the experimental observations. There is no substantial improvement in fit obtained either...

  19. A Methodology for Protective Vibration Monitoring of Hydropower Units Based on the Mechanical Properties.

    Science.gov (United States)

    Nässelqvist, Mattias; Gustavsson, Rolf; Aidanpää, Jan-Olov

    2013-07-01

    It is important to monitor the radial loads in hydropower units in order to protect the machine from harmful radial loads. Existing recommendations in the standards regarding the radial movements of the shaft and bearing housing in hydropower units, ISO-7919-5 (International Organization for Standardization, 2005, "ISO 7919-5: Mechanical Vibration-Evaluation of Machine Vibration by Measurements on Rotating Shafts-Part 5: Machine Sets in Hydraulic Power Generating and Pumping Plants," Geneva, Switzerland) and ISO-10816-5 (International Organization for Standardization, 2000, "ISO 10816-5: Mechanical Vibration-Evaluation of Machine Vibration by Measurements on Non-Rotating Parts-Part 5: Machine Sets in Hydraulic Power Generating and Pumping Plants," Geneva, Switzerland), have alarm levels based on statistical data and do not consider the mechanical properties of the machine. The synchronous speed of the unit determines the maximum recommended shaft displacement and housing acceleration, according to these standards. This paper presents a methodology for the alarm and trip levels based on the design criteria of the hydropower unit and the measured radial loads in the machine during operation. When a hydropower unit is designed, one of its design criteria is to withstand certain loads spectra without the occurrence of fatigue in the mechanical components. These calculated limits for fatigue are used to set limits for the maximum radial loads allowed in the machine before it shuts down in order to protect itself from damage due to high radial loads. Radial loads in hydropower units are caused by unbalance, shape deviations, dynamic flow properties in the turbine, etc. Standards exist for balancing and manufacturers (and power plant owners) have recommendations for maximum allowed shape deviations in generators. These standards and recommendations determine which loads, at a maximum, should be allowed before an alarm is sent that the machine needs maintenance. The radial

  20. Capturing Causality for Fault Diagnosis Based on Multi-Valued Alarm Series Using Transfer Entropy

    Directory of Open Access Journals (Sweden)

    Jianjun Su

    2017-12-01

    Full Text Available Transfer entropy (TE is a model-free approach based on information theory to capture causality between variables, which has been used for the modeling and monitoring of, and fault diagnosis in, complex industrial processes. It is able to detect the causality between variables without assuming any underlying model, but it is computationally burdensome. To overcome this limitation, a hybrid method of TE and the modified conditional mutual information (CMI approach is proposed by using generated multi-valued alarm series. In order to obtain a process topology, TE can generate a causal map of all sub-processes and modified CMI can be used to distinguish the direct connectivity from the above-mentioned causal map by using multi-valued alarm series. The effectiveness and accuracy rate of the proposed method are validated by simulated and real industrial cases (the Tennessee-Eastman process to capture process topology by using multi-valued alarm series.

  1. Shadow Probability of Detection and False Alarm for Median-Filtered SAR Imagery

    Energy Technology Data Exchange (ETDEWEB)

    Raynal, Ann Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). ISR Analysis and Applications Dept.; Doerry, Armin Walter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). ISR Mission Engineering Dept.; Miller, John A. [General Atomics Aeronautical Systems, Inc., San Diego, CA (United States). Mission Systems; Bishop, Edward E. [General Atomics Aeronautical Systems, Inc., San Diego, CA (United States). Mission Systems; Horndt, Volker [General Atomics Aeronautical Systems, Inc., San Diego, CA (United States). Mission Systems

    2014-06-01

    Median filtering reduces speckle in synthetic aperture radar (SAR) imagery while preserving edges, at the expense of coarsening the resolution, by replacing the center pixel of a sliding window by the median value. For shadow detection, this approach helps distinguish shadows from clutter more easily, while preserving shadow shape delineations. However, the nonlinear operation alters the shadow and clutter distributions and statistics, which must be taken into consideration when computing probability of detection and false alarm metrics. Depending on system parameters, median filtering can improve probability of detection and false alarm by orders of magnitude. Herein, we examine shadow probability of detection and false alarm in a homogeneous, ideal clutter background after median filter post-processing. Some comments on multi-look processing effects with and without median filtering are also made.

  2. Specific and unspecific gynecological alarm symptoms -prevalence estimates in different age groups

    DEFF Research Database (Denmark)

    Balasubramaniam, Kirubakaran; Ravn, Pernille; Larsen, Pia V

    2015-01-01

    , and the median number of experienced symptoms was 2 (interquartile range 1-4). The most common symptoms were tiredness (53.0%) and abdominal bloating (36.7%), while postmenopausal bleeding (2.3%) and involuntary weight loss (2.8%) were least frequent. Most of the symptoms were more prevalent among younger women......OBJECTIVE: To determine prevalence estimates of gynecological alarm symptoms in different age groups and to describe common patterns of gynecological symptoms. DESIGN: Web-based cross-sectional survey study. SETTING: Nationwide in Denmark. POPULATION: A random sample of 51 090 women aged 20 years...... guidelines. MAIN OUTCOME MEASURES: Prevalence estimates of self-reported experience of gynecological alarm symptoms within the preceding 4 weeks. RESULTS: A total of 26 466 women (54.5%) participated in the study. Some 80.3% had experienced at least one of the alarm symptoms within the preceding 4 weeks...

  3. Use of urine alarms in toilet training children with intellectual and developmental disabilities: A review.

    Science.gov (United States)

    Levato, Lynne E; Aponte, Courtney A; Wilkins, Jonathan; Travis, Rebekah; Aiello, Rachel; Zanibbi, Katherine; Loring, Whitney A; Butter, Eric; Smith, Tristram; Mruzek, Daniel W

    2016-01-01

    The purpose of this review is to describe and evaluate the existing research on the use of urine alarms in the daytime toilet training of children with intellectual and developmental disabilities (IDD). A systematic literature search yielded 12 studies, many of which were published over a decade ago. The findings suggest that interventions that incorporate the use of urine alarms are promising in the treatment of daytime enuresis for children with IDD; however, more carefully controlled research is needed to confirm these findings and elucidate the precise role urine alarms may play in toileting interventions. Methodological strengths and limitations of the body of research are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Sequence and batch language programs and alarm related C Programs for the 242-A MCS

    Energy Technology Data Exchange (ETDEWEB)

    Berger, J.F.

    1996-04-15

    A Distributive Process Control system was purchased by Project B-534, 242-A Evaporator/Crystallizer Upgrades. This control system, called the Monitor and Control system (MCS), was installed in the 242-A evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict the overall process. To do this, WTSE developed a second alarm scheme.

  5. Video Analysis of Factors Associated With Response Time to Physiologic Monitor Alarms in a Children's Hospital.

    Science.gov (United States)

    Bonafide, Christopher P; Localio, A Russell; Holmes, John H; Nadkarni, Vinay M; Stemler, Shannon; MacMurchy, Matthew; Zander, Miriam; Roberts, Kathryn E; Lin, Richard; Keren, Ron

    2017-06-01

    Bedside monitor alarms alert nurses to life-threatening physiologic changes among patients, but the response times of nurses are slow. To identify factors associated with physiologic monitor alarm response time. This prospective cohort study used 551 hours of video-recorded care administered by 38 nurses to 100 children in a children's hospital medical unit between July 22, 2014, and November 11, 2015. Patient, nurse, and alarm-level factors hypothesized to predict response time. We used multivariable accelerated failure-time models stratified by each nurse and adjusted for clustering within patients to evaluate associations between exposures and response time to alarms that occurred while the nurse was outside the room. The study participants included 38 nurses, 100% (n = 38) of whom were white and 92% (n = 35) of whom were female, and 100 children, 51% (n = 51) of whom were male. The race/ethnicity of the child participants was 45% (n = 45) black or African American, 33% (n = 33) white, 4% (n = 4) Asian, and 18% (n = 18) other. Of 11 745 alarms among 100 children, 50 (0.5%) were actionable. The adjusted median response time among nurses was 10.4 minutes (95% CI, 5.0-15.8) and varied based on the following variables: if the patient was on complex care service (5.3 minutes [95% CI, 1.4-9.3] vs 11.1 minutes [95% CI, 5.6-16.6] among general pediatrics patients), whether family members were absent from the patient's bedside (6.3 minutes [95% CI, 2.2-10.4] vs 11.7 minutes [95% CI, 5.9-17.4] when family present), whether a nurse had less than 1 year of experience (4.4 minutes [95% CI, 3.4-5.5] vs 8.8 minutes [95% CI, 7.2-10.5] for nurses with 1 or more years of experience), if there was a 1 to 1 nursing assignment (3.5 minutes [95% CI, 1.3-5.7] vs 10.6 minutes [95% CI, 5.3-16.0] for nurses caring for 2 or more patients), if there were prior alarms requiring intervention (5.5 minutes [95% CI, 1.5-9.5] vs 10.7 minutes [5.2-16.2] for patients

  6. Quantum dynamics of vibrational excitations and vibrational charge ...

    Indian Academy of Sciences (India)

    Quantum dynamics of vibrational excitations and vibrational charge transfer processes in H+ + O2 collisions at collision energy 23 eV ... The Fritz Haber Research Centre and The Department of Physical Chemisry, Hebrew University of Jerusalem, Jerusalem, Israel 91904; Department of Chemistry, Indian Institute of ...

  7. Constant false alarm rate algorithm for the dim-small target detection based on the distribution characteristics of target coordinates

    Science.gov (United States)

    Fei, Xiao-Liang; Ren, Kan; Qian, Wei-xian; Wang, Peng-cheng

    2015-10-01

    CFAR (Constant False Alarm Rate) is a key technology in Infrared dim-small target detection system. Because the traditional constant false alarm rate detection algorithm gets the probability density distribution which is based on the pixel information of each area in the whole image and calculates the target segmentation threshold of each area by formula of Constant false alarm rate, the problems including the difficulty of probability distribution statistics and large amount of algorithm calculation and long delay time are existing. In order to solve the above problems effectively, a formula of Constant false alarm rate based on target coordinates distribution is presented. Firstly, this paper proposes a new formula of Constant false alarm rate by improving the traditional formula of Constant false alarm rate based on the single grayscale distribution which objective statistical distribution features are introduced. So the control of false alarm according to the target distribution information is implemented more accurately and the problem of high false alarm that is caused of the complex background in local area as the cloud reflection and the ground clutter interference is solved. At the same time, in order to reduce the amount of algorithm calculation and improve the real-time characteristics of algorithm, this paper divides the constant false-alarm statistical area through two-dimensional probability density distribution of target number adaptively which is different from the general identifying methods of constant false-alarm statistical area. Finally, the target segmentation threshold of next frame is calculated by iteration based on the function of target distribution probability density in image sequence which can achieve the purpose of controlling the false alarm until the false alarm is down to the upper limit. The experiment results show that the proposed method can significantly improve the operation time and meet the real-time requirements on

  8. Network-Based Real-time Integrated Fire Detection and Alarm (FDA) System with Building Automation

    Science.gov (United States)

    Anwar, F.; Boby, R. I.; Rashid, M. M.; Alam, M. M.; Shaikh, Z.

    2017-11-01

    Fire alarm systems have become increasingly an important lifesaving technology in many aspects, such as applications to detect, monitor and control any fire hazard. A large sum of money is being spent annually to install and maintain the fire alarm systems in buildings to protect property and lives from the unexpected spread of fire. Several methods are already developed and it is improving on a daily basis to reduce the cost as well as increase quality. An integrated Fire Detection and Alarm (FDA) systems with building automation was studied, to reduce cost and improve their reliability by preventing false alarm. This work proposes an improved framework for FDA system to ensure a robust intelligent network of FDA control panels in real-time. A shortest path algorithmic was chosen for series of buildings connected by fiber optic network. The framework shares information and communicates with each fire alarm panels connected in peer to peer configuration and declare the network state using network address declaration from any building connected in network. The fiber-optic connection was proposed to reduce signal noises, thus increasing large area coverage, real-time communication and long-term safety. Based on this proposed method an experimental setup was designed and a prototype system was developed to validate the performance in practice. Also, the distributed network system was proposed to connect with an optional remote monitoring terminal panel to validate proposed network performance and ensure fire survivability where the information is sequentially transmitted. The proposed FDA system is different from traditional fire alarm and detection system in terms of topology as it manages group of buildings in an optimal and efficient manner.Introduction

  9. Literature survey on anti-vibration gloves

    CSIR Research Space (South Africa)

    Sampson, E

    2003-08-01

    Full Text Available ............................................................................................................... 1 2. HAND ARM VIBRATION SYNDROME (HAVS).......................................................... 2 2.1 Hand-arm vibration................................................. Error! Bookmark not defined. 2.2 Human Response to vibration...

  10. Earthquake alarm; operating the seismograph station at the University of California, Berkeley.

    Science.gov (United States)

    Stump, B.

    1980-01-01

    An alarm bell rings at the seismographic station and at the office of the campus police. It is 3:00 on a foggy San Francisco morning. Somewhere in the world an earthquake has occurred. The police telephone the duty seismologist at home telling him that the alarm has triggered. He makes his way into the seismograph station, bathrobe and all, to locate the earthquake and determine its magnitude. In this way, many seismology graduate students have been initiated into the responsibilities of running a seismographic station. 

  11. Structural Capability of an Organization toward Innovation Capability

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Momeni, Mostafa

    2016-01-01

    indicated that the advantages relying on the internal capabilities of organizations may determine the competitive position of organizations better than environmental opportunities do. Characteristics of firms shows that one of the most internal capabilities that lead the organizations to the strongest...... competitive advantage in the organizations is the innovation capability. The innovation capability is associated with other organizational capabilities, and many organizations have focused on the need to identify innovation capabilities.This research focuses on recognition of the structural aspect...... of innovation capability and proposes a conceptual framework based on a Qualitative Meta Synthesis of academic literature on organizations innovation capability. This is proposed for the development of the concept of innovation capability in the organizations and this paper includes an expert based validation...

  12. Vibrational Sensing in Marine Invertebrates

    Science.gov (United States)

    1997-09-30

    VIBRATIONAL SENSING IN MARINE INVERTEBRATES Peter A. Jumars School of Oceanography University of Washington Box 357940 Seattle, WA 98195-7940 (206...DATES COVERED 00-00-1997 to 00-00-1997 4. TITLE AND SUBTITLE Vibrational Sensing in Marine Invertebrates 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  13. Vibrations and Stability: Solved Problems

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel

    Worked out solutions for exercise problems in J. J. Thomsen 'Vibrations and Stability: Advanced Theory, Analysis, and Tools', Springer, Berlin - Heidelberg, 2003.......Worked out solutions for exercise problems in J. J. Thomsen 'Vibrations and Stability: Advanced Theory, Analysis, and Tools', Springer, Berlin - Heidelberg, 2003....

  14. Buckling and vibration of circular cylindrical shells containing hot liquid

    Science.gov (United States)

    Ganesan, N.; Pradeep, V.

    2005-11-01

    Cylindrical shell filled with hot liquid is analyzed for buckling and vibration behavior using semi-analytical finite element method. A parametric study is conducted on a 316L stainless-steel cylinder filled with hot liquid. The temperature distribution in shell domain is obtained by using axisymmetric eight-node ring finite elements, capable of taking axial variation of temperature into account. Three-node ring elements are used for buckling and vibration analysis, formulated using semi-analytical finite element method. Thermal stress resultants and moment resultants in the shell are estimated and static buckling analysis is carried out to find the buckling temperature of the container for different levels of filling of liquid and for two different boundary conditions. Free vibration analysis carried out by considering initial stress effect and added mass effect due to hot liquid. Two different geometries are considered to study the effect of geometry on buckling temperature.

  15. Planetary Gearbox Fault Detection Using Vibration Separation Techniques

    Science.gov (United States)

    Lewicki, David G.; LaBerge, Kelsen E.; Ehinger, Ryan T.; Fetty, Jason

    2011-01-01

    Studies were performed to demonstrate the capability to detect planetary gear and bearing faults in helicopter main-rotor transmissions. The work supported the Operations Support and Sustainment (OSST) program with the U.S. Army Aviation Applied Technology Directorate (AATD) and Bell Helicopter Textron. Vibration data from the OH-58C planetary system were collected on a healthy transmission as well as with various seeded-fault components. Planetary fault detection algorithms were used with the collected data to evaluate fault detection effectiveness. Planet gear tooth cracks and spalls were detectable using the vibration separation techniques. Sun gear tooth cracks were not discernibly detectable from the vibration separation process. Sun gear tooth spall defects were detectable. Ring gear tooth cracks were only clearly detectable by accelerometers located near the crack location or directly across from the crack. Enveloping provided an effective method for planet bearing inner- and outer-race spalling fault detection.

  16. The origins of vibration theory

    Science.gov (United States)

    Dimarogonas, A. D.

    1990-07-01

    The Ionian School of natural philosophy introduced the scientific method of dealing with natural phenomena and the rigorous proofs for abstract propositions. Vibration theory was initiated by the Pythagoreans in the fifth century BC, in association with the theory of music and the theory of acoustics. They observed the natural frequency of vibrating systems and proved that it is a system property and that it does not depend on the excitation. Pythagoreans determined the fundamental natural frequencies of several simple systems, such as vibrating strings, pipes, vessels and circular plates. Aristoteles and the Peripatetic School founded mechanics and developed a fundamental understanding of statics and dynamics. In Alexandrian times there were substantial engineering developments in the field of vibration. The pendulum as a vibration, and probably time, measuring device was known in antiquity, and was further developed by the end of the first millennium AD.

  17. Design of alarm systems in Swedish nuclear power plants; Utformning av larmsystem i svenska kaernkraftverk

    Energy Technology Data Exchange (ETDEWEB)

    Thunberg, Anna; Osvalder, Anna-Lisa (Dept. of Product and Production Development, Chalmers Univ. of Technology, Goeteborg (Sweden))

    2008-04-15

    Research within the area of improving alarm system design and performance has mainly focused on new alarm systems. However, smaller modernisations of legacy systems are more common in the Swedish nuclear industry than design of totally new systems. This imposes problems when the new system should function together with the old system. This project deals with the special concerns raised by modernisation projects. The objective of the project has been to increase the understanding of the relationship between the operator's performance and the design of the alarm system. Of major concern has been to consider the cognitive abilities of the operator, different operator roles and work situations, and varying need of information. The aim of the project has been to complement existing alarm design guidance and to develop user-centred alarm design concepts. Different case studies have been performed in several industry sectors (nuclear, oil refining, pulp and paper, aviation and medical care) to identify best practice. Several empirical studies have been performed within the nuclear area to investigate the operator's need of information, performance and workload in different operating modes. The aspect of teamwork has also been considered. The analyses show that the operator has different roles in different work situations which affect both the type of information needed and how the information is processed. In full power operation, the interaction between the operator and the alarm system is driven by internal factors and the operator tries to maintain high situation awareness by actively searching for information. The operator wants to optimise the process and need detailed information with possibilities to follow-up and get historical data. In disturbance management, the operator is more dependent on external information presented by the alarm system. The new compilation of alarm guidance is based on the operator's varying needs in different working

  18. Intrusion recognition for optic fiber vibration sensor based on the selective attention mechanism

    Science.gov (United States)

    Xu, Haiyan; Xie, Yingjuan; Li, Min; Zhang, Zhuo; Zhang, Xuewu

    2017-11-01

    Distributed fiber-optic vibration sensors receive extensive investigation and play a significant role in the sensor panorama. A fiber optic perimeter detection system based on all-fiber interferometric sensor is proposed, through the back-end analysis, processing and intelligent identification, which can distinguish effects of different intrusion activities. In this paper, an intrusion recognition based on the auditory selective attention mechanism is proposed. Firstly, considering the time-frequency of vibration, the spectrogram is calculated. Secondly, imitating the selective attention mechanism, the color, direction and brightness map of the spectrogram is computed. Based on these maps, the feature matrix is formed after normalization. The system could recognize the intrusion activities occurred along the perimeter sensors. Experiment results show that the proposed method for the perimeter is able to differentiate intrusion signals from ambient noises. What's more, the recognition rate of the system is improved while deduced the false alarm rate, the approach is proved by large practical experiment and project.

  19. LHC Capabilities for Quarkonia

    CERN Document Server

    Petrushanko, Sergey

    2008-01-01

    The measurement of the charmonium and bottomonium resonances in nucleus-nucleus collisions provides crucial information on high-density QCD matter. First, the suppression of quarkonia production is generally agreed to be one of the most direct probes of quark-gluon plasma formation. The observation of anomalous J/$\\psi$ suppression at the CERN-SPS and at RHIC is well established but the clarification of some important remaining questions requires equivalent studies of the $\\Upsilon$ family, only possible at the LHC energies. Second, the production of heavy-quarks proceeds mainly via gluon-gluon fusion processes and, as such, is sensitive to saturation of the gluon density at low-x in the nucleus. Measured departures from the expected vacuum quarkonia cross-sections in Pb+Pb collisions at the LHC will thus provide valuable information not only on the thermodynamical state of the produced partonic medium, but also on the initial-state modifications of the nuclear parton distribution functions. The capabilities ...

  20. Mobile systems capability plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    This plan was prepared to initiate contracting for and deployment of these mobile system services. 102,000 cubic meters of retrievable, contact-handled TRU waste are stored at many sites around the country. Also, an estimated 38,000 cubic meters of TRU waste will be generated in the course of waste inventory workoff and continuing DOE operations. All the defense TRU waste is destined for disposal in WIPP near Carlsbad NM. To ship TRU waste there, sites must first certify that the waste meets WIPP waste acceptance criteria. The waste must be characterized, and if not acceptable, subjected to additional processing, including repackaging. Most sites plan to use existing fixed facilities or open new ones between FY1997-2006 to perform these functions; small-quantity sites lack this capability. An alternative to fixed facilities is the use of mobile systems mounted in trailers or skids, and transported to sites. Mobile systems will be used for all characterization and certification at small sites; large sites can also use them. The Carlsbad Area Office plans to pursue a strategy of privatization of mobile system services, since this offers a number of advantages. To indicate the possible magnitude of the costs of deploying mobile systems, preliminary estimates of equipment, maintenance, and operating costs over a 10-year period were prepared and options for purchase, lease, and privatization through fixed-price contracts considered.

  1. Development and Application of a Clinical Microsystem Simulation Methodology for Human Factors-Based Research of Alarm Fatigue.

    Science.gov (United States)

    Kobayashi, Leo; Gosbee, John W; Merck, Derek L

    2017-07-01

    (1) To develop a clinical microsystem simulation methodology for alarm fatigue research with a human factors engineering (HFE) assessment framework and (2) to explore its application to the comparative examination of different approaches to patient monitoring and provider notification. Problems with the design, implementation, and real-world use of patient monitoring systems result in alarm fatigue. A multidisciplinary team is developing an open-source tool kit to promote bedside informatics research and mitigate alarm fatigue. Simulation, HFE, and computer science experts created a novel simulation methodology to study alarm fatigue. Featuring multiple interconnected simulated patient scenarios with scripted timeline, "distractor" patient care tasks, and triggered true and false alarms, the methodology incorporated objective metrics to assess provider and system performance. Developed materials were implemented during institutional review board-approved study sessions that assessed and compared an experimental multiparametric alerting system with a standard monitor telemetry system for subject response, use characteristics, and end-user feedback. A four-patient simulation setup featuring objective metrics for participant task-related performance and response to alarms was developed along with accompanying structured HFE assessment (questionnaire and interview) for monitor systems use testing. Two pilot and four study sessions with individual nurse subjects elicited true alarm and false alarm responses (including diversion from assigned tasks) as well as nonresponses to true alarms. In-simulation observation and subject questionnaires were used to test the experimental system's approach to suppressing false alarms and alerting providers. A novel investigative methodology applied simulation and HFE techniques to replicate and study alarm fatigue in controlled settings for systems assessment and experimental research purposes.

  2. Differences in the response of a striped dolphin (Stenella coeruleoalba) and a harbour porpoise (Phocoena phocoena) to an acoustic alarm.

    Science.gov (United States)

    Kastelein, R A; Jennings, N; Verboom, W C; de Haan, D; Schooneman, N M

    2006-04-01

    Small cetacean bycatch in gillnet fisheries may be reduced by deterring odontocetes from nets acoustically. However, different odontocete species may respond differently to acoustic signals from alarms. Therefore, in this study a striped dolphin and a harbour porpoise were subjected simultaneously to sounds produced by the XP-10 experimental acoustic alarm. The alarm produced 0.3s tonal signals randomly selected from a set of 16 with fundamental frequencies between 9 and 15kHz, with a constant pulse interval of 4.0s (duty cycle 8%) and a Source Level range of 133-163dB re 1muPa (rms). The effect of the alarm was judged by comparing the animals' respiration rate and position relative to the alarm during test periods with those during baseline periods. As in a previous study on two porpoises with the same alarm, the porpoise in the present study reacted strongly to the alarm by swimming away from it and increasing his respiration rate. The striped dolphin, however, showed no reaction to the active alarm. Based on harbour porpoise audiograms and the specific audiogram of the striped dolphin in the present study, and the low background noise levels during the experiment, both animals must have heard the alarm signals clearly. This study indicates that cetacean species are not equally sensitive to human-made noise disturbance. Therefore, source levels of acoustic alarms should be adapted to the species they are supposed to deter. In addition, alarms should be tested on each odontocete species for which they are intended to reduce bycatch.

  3. Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Provenza, Andrew J.

    2011-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

  4. Reduction of personnel vibration hazards in underground coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Oh, X.; Middlin, A. (Vipac Engineers and Scientists Ltd. (Australia))

    1991-03-01

    Whole-Body Vibration (WBV) due to the 'rough ride' in vehicles is a major source of back and neck injury in underground coal mines. Hand-Arm Vibration (HAV) from hand held equipment can also cause long term health damage. Surveys in three collieries in NSW have been conducted to measure the vibration levels to which miners are being exposed and to assess them according to the two relevant Australian Standards namely AS2670 and AS2763. WBV results indicated that shock loadings must be the source of back and neck injuries that are occurring due to 'rough ride'. Existing off-the-shelf seat suspensions were demonstrated to be inadequate for providing effective shock isolation, due to them being prone to bottoming out under rough conditions, and due their scissor action mechanism becoming rapidly jammed by dirt to the point where they become rigid. Commercially available seats were evaluated and tested on a hydraulic shaker, but none proved able to provide the required vibration isolation. A prototype seat suspension was developed by Vipac. This suspension was shaker tested and trialled in low loaders at two collieries. The seat proved capable of cushioning shock loads without bottoming out, as well as attenuating the dominant vibration at 2.5 Hz and higher. This suspension with encapsulated mechanism could be readily adapted to suit a wide range of underground vehicles. The HAV survey results identified the Wombat roof-bolter as the major item requiring vibration level reductions. Extensive investigations resulted in the design of a prototype vibration isolated handle. During field tests this prototype handle reduced the HAV level such that the Exposure Time (10th percentile) was increased from 7 to 11.5 years. Guidelines are presented for additional developments which would further improve this performance and result in a handle design suitable for retrofitting to existing roof bolters.

  5. Bridge Condition Assessment based on Vibration Responses of Passenger Vehicle

    Science.gov (United States)

    Miyamoto, Ayaho; Yabe, Akito

    2011-07-01

    In this paper, we propose a new method of assessing the condition of existing short- and medium-span reinforced/prestressed concrete bridges based on vibration monitoring data obtained from a public bus. This paper not only describes details of a prototype monitoring system that uses information technology and sensors capable of providing more accurate knowledge of bridge performance than conventional ways but also shows a few specific examples of bridge condition assessment based on vehicle vibrations measured by using an in-service public bus equipped with vibration measurement instrumentation. This paper also describes a sensitivity analysis of deteriorating bridges based on simulation of the acceleration response of buses conducted by the "substructure method" employing a finite element model to verify the above bridge performance results. The main conclusions obtained in this study can be summarized as follows: (1) Because the vibration responses of passenger vehicles, such as buses, have a good linear relationship with the vibration responses of the target bridges, the proposed system can be used as a practical monitoring system for bridge condition assessment. (2) The results of sensitivity analysis performed by the substructure method show that bus vibration responses are useful for evaluating target bridge performance. (3) The proposed method was applied to a network of real bridges in a local area to evaluate its effectiveness. The results indicate that the proposed method can be used to prioritize the repair/strengthening works of existing bridges based on various vibration information in order to help bridge administrators establish rational maintenance strategies.

  6. Bridge Condition Assessment based on Vibration Responses of Passenger Vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Ayaho [Graduate School of Science and Engineering, Yamaguchi University, Ube (Japan); Yabe, Akito, E-mail: miya818@yamaguchi-u.ac.jp, E-mail: nagai@kke.co.jp [Seismic Engineering Department, KOZO KEIKAKU Engineering Inc. Tokyo (Japan)

    2011-07-19

    In this paper, we propose a new method of assessing the condition of existing short- and medium-span reinforced/prestressed concrete bridges based on vibration monitoring data obtained from a public bus. This paper not only describes details of a prototype monitoring system that uses information technology and sensors capable of providing more accurate knowledge of bridge performance than conventional ways but also shows a few specific examples of bridge condition assessment based on vehicle vibrations measured by using an in-service public bus equipped with vibration measurement instrumentation. This paper also describes a sensitivity analysis of deteriorating bridges based on simulation of the acceleration response of buses conducted by the 'substructure method' employing a finite element model to verify the above bridge performance results. The main conclusions obtained in this study can be summarized as follows: (1) Because the vibration responses of passenger vehicles, such as buses, have a good linear relationship with the vibration responses of the target bridges, the proposed system can be used as a practical monitoring system for bridge condition assessment. (2) The results of sensitivity analysis performed by the substructure method show that bus vibration responses are useful for evaluating target bridge performance. (3) The proposed method was applied to a network of real bridges in a local area to evaluate its effectiveness. The results indicate that the proposed method can be used to prioritize the repair/strengthening works of existing bridges based on various vibration information in order to help bridge administrators establish rational maintenance strategies.

  7. Design of the intelligent smoke alarm system based on photoelectric smoke

    Science.gov (United States)

    Ma, Jiangfei; Yang, Xiufang; Wang, Peipei

    2017-02-01

    This paper designed a kind of intelligent smoke alarm system based on photoelectric smoke detector and temperature, The system takes AT89C51 MCU as the core of hardware control and Labview as the host computer monitoring center.The sensor system acquires temperature signals and smoke signals, the MCU control A/D by Sampling and converting the output analog signals , and then the two signals will be uploaded to the host computer through the serial communication. To achieve real-time monitoring of smoke and temperature in the environment, LabVIEW monitoring platform need to hold, process, analysis and display these samping signals. The intelligent smoke alarm system is suitable for large scale shopping malls and other public places, which can greatly reduce the false alarm rate of fire, The experimental results show that the system runs well and can alarm when the setting threshold is reached,and the threshold parameters can be adjusted according to the actual conditions of the field. The system is easy to operate, simple in structure, intelligent, low cost, and with strong practical value.

  8. Honey Bees Modulate Their Olfactory Learning in the Presence of Hornet Predators and Alarm Component.

    Directory of Open Access Journals (Sweden)

    Zhengwei Wang

    Full Text Available In Southeast Asia the native honey bee species Apis cerana is often attacked by hornets (Vespa velutina, mainly in the period from April to November. During the co-evolution of these two species honey bees have developed several strategies to defend themselves such as learning the odors of hornets and releasing alarm components to inform other mates. However, so far little is known about whether and how honey bees modulate their olfactory learning in the presence of the hornet predator and alarm components of honey bee itself. In the present study, we test for associative olfactory learning of A. cerana in the presence of predator odors, the alarm pheromone component isopentyl acetate (IPA, or a floral odor (hexanal as a control. The results show that bees can detect live hornet odors, that there is almost no association between the innately aversive hornet odor and the appetitive stimulus sucrose, and that IPA is less well associated with an appetitive stimulus when compared with a floral odor. In order to imitate natural conditions, e.g. when bees are foraging on flowers and a predator shows up, or alarm pheromone is released by a captured mate, we tested combinations of the hornet odor and floral odor, or IPA and floral odor. Both of these combinations led to reduced learning scores. This study aims to contribute to a better understanding of the prey-predator system between A. cerana and V. velutina.

  9. Alarming plant dieback in the Outeniquas : is this an indication of global warming? Monitoring plant populations

    CSIR Research Space (South Africa)

    Rebelo, T

    2009-03-01

    Full Text Available With enhanced global warming predicted to have major impacts on our flora and fauna, environmentalists are on the lookout for any signs of our flora responding to climate change. So it was with alarm that Nick Helme reported mass mortality...

  10. Honey Bees Modulate Their Olfactory Learning in the Presence of Hornet Predators and Alarm Component.

    Science.gov (United States)

    Wang, Zhengwei; Qu, Yufeng; Dong, Shihao; Wen, Ping; Li, Jianjun; Tan, Ken; Menzel, Randolf

    2016-01-01

    In Southeast Asia the native honey bee species Apis cerana is often attacked by hornets (Vespa velutina), mainly in the period from April to November. During the co-evolution of these two species honey bees have developed several strategies to defend themselves such as learning the odors of hornets and releasing alarm components to inform other mates. However, so far little is known about whether and how honey bees modulate their olfactory learning in the presence of the hornet predator and alarm components of honey bee itself. In the present study, we test for associative olfactory learning of A. cerana in the presence of predator odors, the alarm pheromone component isopentyl acetate (IPA), or a floral odor (hexanal) as a control. The results show that bees can detect live hornet odors, that there is almost no association between the innately aversive hornet odor and the appetitive stimulus sucrose, and that IPA is less well associated with an appetitive stimulus when compared with a floral odor. In order to imitate natural conditions, e.g. when bees are foraging on flowers and a predator shows up, or alarm pheromone is released by a captured mate, we tested combinations of the hornet odor and floral odor, or IPA and floral odor. Both of these combinations led to reduced learning scores. This study aims to contribute to a better understanding of the prey-predator system between A. cerana and V. velutina.

  11. The Role of Social Influence on How Residence Hall Inhabitants Respond to Fire Alarms

    Science.gov (United States)

    Leytem, Michael; Stark, Emily

    2016-01-01

    College resident halls pose a threat for a catastrophic event in the case of fire, but little research has examined potential influences on students' responses to fire alarms, particularly the role of social influence in affecting their behaviors. In the current study, residence hall inhabitants reported their knowledge about fire safety, their…

  12. Installation of Computerized Procedure System and Advanced Alarm System in the Human Systems Simulation Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spielman, Zachary Alexander [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-04-01

    This report describes the installation of two advanced control room technologies, an advanced alarm system and a computerized procedure system, into the Human Systems Simulation Laboratory (HSSL). Installation of these technologies enables future phases of this research by providing a platform to systematically evaluate the effect of these technologies on operator and plant performance.

  13. An alarm pheromone modulates appetitive olfactory learning in the honeybee (Apis mellifera

    Directory of Open Access Journals (Sweden)

    Elodie Urlacher

    2010-08-01

    Full Text Available In honeybees, associative learning is embedded in a social context as bees possess a highly complex social organization in which communication among individuals is mediated by dance behavior informing about food sources, and by a high variety of pheromones that maintain the social links between individuals of a hive. Proboscis extension response (PER conditioning is a case of appetitive learning, in which harnessed bees learn to associate odor stimuli with sucrose reward in the laboratory. Despite its recurrent use as a tool for uncovering the behavioral, cellular and molecular bases underlying associative learning, the question of whether social signals (pheromones affect appetitive learning has not been addressed in this experimental framework. This situation contrasts with reports underlining that foraging activity of bees is modulated by alarm pheromones released in the presence of a potential danger. Here, we show that appetitive learning is impaired by the sting alarm pheromone (SAP which, when released by guards, recruits foragers to defend the hive. This effect is mimicked by the main component of SAP, isopentyl acetate (IPA, is dose-dependent and lasts up to 24h. Learning impairment is specific to alarm signal exposure and is independent of the odorant used for conditioning. Our results suggest that learning impairment may be a response to the biological significance of SAP as an alarm signal, which would detract bees from responding to any appetitive stimuli in a situation in which such responses would be of secondary importance.

  14. Alarm communication: a new function for the scent-gland secretion in harvestmen (Arachnida: Opiliones)

    Science.gov (United States)

    Machado, Glauco; Bonato, Vinícius; Oliveira, Paulo

    2002-05-01

    Most harvestmen are nocturnal, nonacoustical, and nonvisual arthropods. They have a pair of exocrine glands on the cephalothorax that produce defensive volatile secretions. We investigated in the field the possible alarm effect of these secretions in the gregarious harvestman Goniosoma aff. proximum. A cotton swab soaked with the species' own exudate (treatment), or with water (control), was held 1-2 cm from the center of harvestmen aggregations. The results showed that the gland secretion elicits an alarm response in Goniosoma: whereas 73.3% of the aggregations dispersed after being stimulated with the gland exudate, only 3.3% responded to the water control. Respondent groups are larger than non-respondent groups, and the time of reaction to the secretion was inversely related to group size. This is the first demonstration of a chemically-mediated alarm effect in harvestmen. The alarm response in gregarious harvestmen has possibly evolved as a by-product of a primarily defensive reaction in the context of predator avoidance. The discovery of this novel function of scent-gland secretion is meaningful in view of the widespread occurrence of gregarious habit among species of the order Opiliones.

  15. Fast estimation of false alarm probabilities of STAP detectors - the AMF

    NARCIS (Netherlands)

    Srinivasan, R.; Rangaswamy, Muralidhar

    2005-01-01

    This paper describes an attempt to harness the power of adaptive importance sampling techniques for estimating false alarm probabilities of detectors that use space-time adaptive processing. Fast simulation using these techniques have been notably successful in the study of conventional constant

  16. Correcting the Enuresis of a Hearing-Impaired, Developmentally Disabled Adolescent Using an Auditory Enuresis Alarm.

    Science.gov (United States)

    Hanson, Ronald H.

    1983-01-01

    The enuresis of a hearing-impaired, developmentally disabled adolescent was corrected through the use of an auditory alarm and specific training procedures. The young man progressed from wetting the bed every night to being consistently dry after five weeks of treatment. He has remaind dry for over two years. (Author/CL)

  17. An alarm pheromone modulates appetitive olfactory learning in the honeybee (apis mellifera).

    Science.gov (United States)

    Urlacher, Elodie; Francés, Bernard; Giurfa, Martin; Devaud, Jean-Marc

    2010-01-01

    In honeybees, associative learning is embedded in a social context as bees possess a highly complex social organization in which communication among individuals is mediated by dance behavior informing about food sources, and by a high variety of pheromones that maintain the social links between individuals of a hive. Proboscis extension response conditioning is a case of appetitive learning, in which harnessed bees learn to associate odor stimuli with sucrose reward in the laboratory. Despite its recurrent use as a tool for uncovering the behavioral, cellular, and molecular bases underlying associative learning, the question of whether social signals (pheromones) affect appetitive learning has not been addressed in this experimental framework. This situation contrasts with reports underlining that foraging activity of bees is modulated by alarm pheromones released in the presence of a potential danger. Here, we show that appetitive learning is impaired by the sting alarm pheromone (SAP) which, when released by guards, recruits foragers to defend the hive. This effect is mimicked by the main component of SAP, isopentyl acetate, is dose-dependent and lasts up to 24 h. Learning impairment is specific to alarm signal exposure and is independent of the odorant used for conditioning. Our results suggest that learning impairment may be a response to the biological significance of SAP as an alarm signal, which would detract bees from responding to any appetitive stimuli in a situation in which such responses would be of secondary importance.

  18. Predator guild does not influence orangutan alarm call rates and combinations

    NARCIS (Netherlands)

    Lameira, A.R.; de Vries, H.; Hardus, M.E.; Hall, C.P.A.; Mitra-Setia, T.; Spruijt, B.M.; Kershenbaum, A.; Sterck, E.H.M.; van Noordwijk, M.; van Schaick, C.; Wich, S.A.

    2013-01-01

    Monkey alarm calls have shown that in the primate clade, combinatorial rules in acoustic communication are not exclusive to humans. A recent hypothesis suggests that the number of different call combinations in monkeys increases with increased number of predator species. However, the existence of

  19. AN APPROACH TO ALLEVIATE THE FALSE ALARM IN BUILDING CHANGE DETECTION FROM URBAN VHR IMAGE

    Directory of Open Access Journals (Sweden)

    J. Chen

    2016-06-01

    Full Text Available Building change detection from very-high-resolution (VHR urban remote sensing image frequently encounter the challenge of serious false alarm caused by different illumination or viewing angles in bi-temporal images. An approach to alleviate the false alarm in urban building change detection is proposed in this paper. Firstly, as shadows casted by urban buildings are of distinct spectral and shape feature, it adopts a supervised object-based classification technique to extract them in this paper. Secondly, on the opposite direction of sunlight illumination, a straight line is drawn along the principal orientation of building in every extracted shadow region. Starting from the straight line and moving toward the sunlight direction, a rectangular area is constructed to cover partial shadow and rooftop of each building. Thirdly, an algebra and geometry invariant based method is used to abstract the spatial topological relationship of the potential unchanged buildings from all central points of the rectangular area. Finally, based on an oriented texture curvature descriptor, an index is established to determine the actual false alarm in building change detection result. The experiment results validate that the proposed method can be used as an effective framework to alleviate the false alarm in building change detection from urban VHR image.

  20. Impact of Personnel Capabilities on Organizational Innovation Capability

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Momeni, Mostafa

    2016-01-01

    One of the most dynamic capabilities that lead to the strongest competitive advantage in the organizations is the innovation capability. Analysing the development of a firm’s innovation capability is an important research project, and can help organizations to achieve competitive advantage in thi...

  1. Vibration response of misaligned rotors

    Science.gov (United States)

    Patel, Tejas H.; Darpe, Ashish K.

    2009-08-01

    Misalignment is one of the common faults observed in rotors. Effect of misalignment on vibration response of coupled rotors is investigated in the present study. The coupled rotor system is modelled using Timoshenko beam elements with all six dof. An experimental approach is proposed for the first time for determination of magnitude and harmonic nature of the misalignment excitation. Misalignment effect at coupling location of rotor FE model is simulated using nodal force vector. The force vector is found using misalignment coupling stiffness matrix, derived from experimental data and applied misalignment between the two rotors. Steady-state vibration response is studied for sub-critical speeds. Effect of the types of misalignment (parallel and angular) on the vibration behaviour of the coupled rotor is examined. Along with lateral vibrations, axial and torsional vibrations are also investigated and nature of the vibration response is also examined. It has been found that the misalignment couples vibrations in bending, longitudinal and torsional modes. Some diagnostic features in the fast Fourier transform (FFT) of torsional and longitudinal response related to parallel and angular misalignment have been revealed. Full spectra and orbit plots are effectively used to reveal the unique nature of misalignment fault leading to reliable misalignment diagnostic information, not clearly brought out by earlier studies.

  2. Alarm Variables for Dengue Outbreaks: A Multi-Centre Study in Asia and Latin America.

    Directory of Open Access Journals (Sweden)

    Leigh R Bowman

    Full Text Available Worldwide, dengue is an unrelenting economic and health burden. Dengue outbreaks have become increasingly common, which place great strain on health infrastructure and services. Early warning models could allow health systems and vector control programmes to respond more cost-effectively and efficiently.The Shewhart method and Endemic Channel were used to identify alarm variables that may predict dengue outbreaks. Five country datasets were compiled by epidemiological week over the years 2007-2013. These data were split between the years 2007-2011 (historic period and 2012-2013 (evaluation period. Associations between alarm/ outbreak variables were analysed using logistic regression during the historic period while alarm and outbreak signals were captured during the evaluation period. These signals were combined to form alarm/ outbreak periods, where 2 signals were equal to 1 period. Alarm periods were quantified and used to predict subsequent outbreak periods. Across Mexico and Dominican Republic, an increase in probable cases predicted outbreaks of hospitalised cases with sensitivities and positive predictive values (PPV of 93%/ 83% and 97%/ 86% respectively, at a lag of 1-12 weeks. An increase in mean temperature ably predicted outbreaks of hospitalised cases in Mexico and Brazil, with sensitivities and PPVs of 79%/ 73% and 81%/ 46% respectively, also at a lag of 1-12 weeks. Mean age was predictive of hospitalised cases at sensitivities and PPVs of 72%/ 74% and 96%/ 45% in Mexico and Malaysia respectively, at a lag of 4-16 weeks.An increase in probable cases was predictive of outbreaks, while meteorological variables, particularly mean temperature, demonstrated predictive potential in some countries, but not all. While it is difficult to define uniform variables applicable in every country context, the use of probable cases and meteorological variables in tailored early warning systems could be used to highlight the occurrence of dengue

  3. Sequence and batch language programs and alarm-related ``C`` programs for the 242-A MCS. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Berger, J.F.

    1995-03-01

    A Distributive Process Control system was purchased by Project B-534, ``242-A Evaporator/Crystallizer Upgrades``. This control system, called the Monitor and Control System (MCS), was installed in the 242-A Evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict the overall process. To do this, WTSE developed a second alarm scheme which uses special programs, annunciator keys, and process graphics. The special programs are written in two languages; Sequence and Batch Language (SABL), and ``C`` language. The WTSE-developed alarm scheme works as described below: SABL relates signals and alarms to the annunciator keys, called SKID keys. When an alarm occurs, a SABL program causes a SKID key to flash, and if the alarm is of yellow or white priority then a ``C`` program turns on an audible horn (the D/3 system uses a different audible horn for the red priority alarms). The horn and flashing key draws the attention of the operator.

  4. Persons with Mild or Moderate Alzheimer's Disease Learn to Use Urine Alarms and Prompts to Avoid Large Urinary Accidents

    Science.gov (United States)

    Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Bosco, Andrea; Zonno, Nadia; Badagliacca, Francesco

    2011-01-01

    This study assessed whether three patients with Alzheimer's disease could learn to use urine alarms and caregivers' prompts to eliminate large urinary accidents. As soon as the patient began to release urine, the alarm system presented auditory and vibratory signals. In relation to those signals, the caregiver would prompt/encourage the patient to…

  5. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.-TB/ALL. 31.35-5 Section 31.35-5 Shipping COAST GUARD, DEPARTMENT... Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.—TB/ALL. All tank...

  6. Alarming signs and symptoms in febrile children in primary care: an observational cohort study in The Netherlands.

    Directory of Open Access Journals (Sweden)

    Gijs Elshout

    Full Text Available CONTEXT: Febrile children in primary care have a low risk for serious infection. Although several alarming signs and symptoms are proposed to have predictive value for serious infections, most are based on research in secondary care. The frequency of alarming signs/symptoms has not been established in primary care; however, in this setting differences in occurrence may influence their predictive value for serious infections. OBJECTIVE: To determine the frequency of alarming signs/symptoms in febrile children in primary care. DESIGN: Observational cohort study. Clinical information was registered in a semi-structured way and manually recoded. SETTING: General practitioners' out-of-hours service. SUBJECTS: Face-to-face patient contacts concerning children (aged ≤16 years with fever were eligible for inclusion. MAIN OUTCOME MEASURES: Frequency of 18 alarming signs and symptoms as reported in the literature. RESULTS: A total of 10,476 patient contacts were included. The frequency of alarming signs/symptoms ranged from n = 1 (ABC instability; 40°C as reported by the parents; 12.9% to 8,647 contacts (parental concern; 82.5%. CONCLUSION: Although the prevalence of specific alarming signs/symptoms is low in primary care, ≥50% of children have one or more alarming signs/symptoms. There is a need to determine the predictive value of alarming signs/symptoms not only for serious infections in primary care, but as well for increased risk of a complicated course of the illness.

  7. Justice and the human alarm system: The impact of exclamation points and flashing lights on the justice judgment process

    NARCIS (Netherlands)

    Bos, K. van den; Ham, J.; Lind, E.A.; Simonis, M.J.; Essen, W.J. van; Rijpkema, M.

    2008-01-01

    Extending theory within the justice domain and work on the human alarm system, the current paper argues that the process by which justice judgments are formed may be influenced reliably by the activation of psychological systems that people use to detect and handle alarming situations. Building on

  8. Tissue vibration in prolonged running.

    Science.gov (United States)

    Friesenbichler, Bernd; Stirling, Lisa M; Federolf, Peter; Nigg, Benno M

    2011-01-04

    The impact force in heel-toe running initiates vibrations of soft-tissue compartments of the leg that are heavily dampened by muscle activity. This study investigated if the damping and frequency of these soft-tissue vibrations are affected by fatigue, which was categorized by the time into an exhaustive exercise. The hypotheses were tested that (H1) the vibration intensity of the triceps surae increases with increasing fatigue and (H2) the vibration frequency of the triceps surae decreases with increasing fatigue. Tissue vibrations of the triceps surae were measured with tri-axial accelerometers in 10 subjects during a run towards exhaustion. The frequency content was quantified with power spectra and wavelet analysis. Maxima of local vibration intensities were compared between the non-fatigued and fatigued states of all subjects. In axial (i.e. parallel to the tibia) and medio-lateral direction, most local maxima increased with fatigue (supporting the first hypothesis). In anterior-posterior direction no systematic changes were found. Vibration frequency was minimally affected by fatigue and frequency changes did not occur systematically, which requires the rejection of the second hypothesis. Relative to heel-strike, the maximum vibration intensity occurred significantly later in the fatigued condition in all three directions. With fatigue, the soft tissue of the triceps surae oscillated for an extended duration at increased vibration magnitudes, possibly due to the effects of fatigue on type II muscle fibers. Thus, the protective mechanism of muscle tuning seems to be reduced in a fatigued muscle and the risk of potential harm to the tissue may increase. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. NASTRAN nonlinear vibration analysis of beam and frame structures

    Science.gov (United States)

    Mei, C.; Rogers, J. L., Jr.

    1975-01-01

    A capability for the nonlinear vibration analysis of beam and frame structures suitable for use with NASTRAN level 15.5 is described. The nonlinearity considered is due to the presence of axial loads induced by longitudinal end restraints and lateral displacements that are large compared to the beam height. A brief discussion is included of the mathematical analysis and the geometrical stiffness matrix for a prismatic beam (BAR) element. Also included are a brief discussion of the equivalent linearization iterative process used to determine the nonlinear frequency, the required modifications to subroutines DBAR and XMPLBD of the NASTRAN code, and the appropriate vibration capability, four example problems are presented. Comparisons with existing experimental and analytical results show that excellent accuracy is achieved with NASTRAN in all cases.

  10. Molecular vibrations the theory of infrared and Raman vibrational spectra

    CERN Document Server

    Wilson, E Bright; Cross, Paul C

    1980-01-01

    Pedagogical classic and essential reference focuses on mathematics of detailed vibrational analyses of polyatomic molecules, advancing from application of wave mechanics to potential functions and methods of solving secular determinant.

  11. Avoid heat transfer equipment vibration

    Energy Technology Data Exchange (ETDEWEB)

    Ganapathy, V.

    1987-06-01

    Tube bundles in heat exchangers, boilers, superheaters and heaters are often subject to vibration and noise problems. Vibration can lead to tube thinning and wear, resulting in tube failures. Excessive noise can be a problem to plant operating personnel. Large gas pressure drop across the equipment is also a side effect, which results in large operating costs. With the design checks presented in this paper, one can predict during design if problems associated with noise and vibration are likely to occur in petroleum refineries.

  12. The development of capability indicators

    NARCIS (Netherlands)

    Anand, Paul; Hunter, Graham; Carter, Ian; Dowding, Keith; Guala, Francesco; Van Hees, Martin

    2009-01-01

    This paper is motivated by sustained interest in the capabilities approach to welfare economics combined with the paucity of economic statistics that measure capabilities at the individual level. Specifically, it takes a much discussed account of the normatively desirable capabilities constitutive

  13. The Capability to Hold Property

    NARCIS (Netherlands)

    Claassen, Rutger

    2015-01-01

    This paper discusses the question of whether a capability theory of justice (such as that of Martha Nussbaum) should accept a basic “capability to hold property.” Answering this question is vital for bridging the gap between abstract capability theories of justice and their institutional

  14. Associations between health care seeking and socioeconomic and demographic determinants among people reporting alarm symptoms of cancer

    DEFF Research Database (Denmark)

    Svendsen, Rikke P; Jarbol, Dorte E; Larsen, Pia V

    2013-01-01

    Late diagnosis of cancer may partly be explained by the fact that some patients do not seek health care promptly when experiencing an alarm symptom. Socioeconomic and demographic differences exist concerning knowledge and awareness of cancer alarm symptoms in the general population and socioecono...... and socioeconomic differences are found in cancer incidence and survival. We therefore hypothesise that socioeconomic and demographic differences in health care-seeking behaviour are present among people with alarm symptoms.......Late diagnosis of cancer may partly be explained by the fact that some patients do not seek health care promptly when experiencing an alarm symptom. Socioeconomic and demographic differences exist concerning knowledge and awareness of cancer alarm symptoms in the general population...

  15. Factors influencing when intensive care unit nurses go to the bedside to investigate patient related alarms: A descriptive qualitative study.

    Science.gov (United States)

    Despins, Laurel A

    2017-12-01

    This study examines what prompts the intensive care unit (ICU) nurse to go to the patient's bedside to investigate an alarm and the influences on the nurse's determination regarding how quickly this needs to occur. A qualitative descriptive design guided data collection and analysis. Individual semi-structured interviews were conducted. Thematic analysis guided by the Patient Risk Detection Theoretical Framework was applied to the data. Four specialty intensive care units in an academic medical center. ICU nurses go the patient's bedside in response to an alarm to catch patient deterioration and avert harm. Their determination of the immediacy of patient risk and their desire to prioritize their bedside investigations to true alarms influences how quickly they proceed to the bedside. Ready visual access to physiological data and waveform configurations, experience, teamwork, and false alarms are important determinants in the timing of ICU nurses' bedside alarm investigations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Note: fast, small, and low vibration mechanical laser shutters.

    Science.gov (United States)

    Martínez, S; Hernández, L; Reyes, D; Gomez, E; Ivory, M; Davison, C; Aubin, S

    2011-04-01

    We present three novel mechanical laser shutter designs based, respectively, on a stepper motor, a relay, and a piezoelectric actuator. Each shutter type is ideally suited to a specific shuttering application. The stepper motor is well suited for applications requiring low vibrations, the relay is compact and capable of rapid bursts, and the piezoelectric is 2 orders of magnitude faster than other available mechanical shutters. © 2011 American Institute of Physics

  17. Associations between reporting of cancer alarm symptoms and socioeconomic and demographic determinants: a population-based, cross-sectional study

    Directory of Open Access Journals (Sweden)

    Svendsen Rikke

    2012-08-01

    Full Text Available Abstract Background Reporting of symptoms which may signal cancer is the first step in the diagnostic pathway of cancer diseases. Cancer alarm symptoms are common in the general population. Public awareness and knowledge of cancer symptoms are sparse, however, and many people do not seek medical help when having possible cancer symptoms. As social inequality is associated with cancer knowledge, cancer awareness, and information-seeking, our hypothesis is that social inequality may also exist in the general population with respect to reporting of cancer alarm symptoms. The aim of this study was to investigate possible associations between socioeconomic and demographic determinants and reporting of common cancer alarm symptoms. Methods A cross-sectional questionnaire survey was performed based on a stratified sample of the Danish general population. A total of 13 777 randomly selected persons aged 20 years and older participated. Our main outcome measures were weighted prevalence estimates of self-reporting one of the following cancer alarm symptoms during the preceding 12 months: a lump in the breast, coughing for more than 6 weeks, seen blood in urine, or seen blood in stool. Logistic regression models were used to calculate unadjusted and adjusted odds ratios with 95% confidence intervals for the associations between each covariate and reporting of cancer alarm symptoms. Results A total of 2 098 (15.7% of the participants reported one or more cancer alarm symptoms within the preceding 12 months. Women, subjects out of the workforce, and subjects with a cancer diagnosis had statistically significantly higher odds of reporting one or more cancer alarm symptoms. Subjects with older age and subjects living with a partner had lower odds of reporting one or more cancer alarm symptoms. When analysing the four alarm symptoms of cancer separately most tendencies persisted. Conclusions Socioeconomic and demographic determinants are associated with self

  18. 14 CFR 33.63 - Vibration.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Vibration. 33.63 Section 33.63 Aeronautics... STANDARDS: AIRCRAFT ENGINES Design and Construction; Turbine Aircraft Engines § 33.63 Vibration. Each engine... because of vibration and without imparting excessive vibration forces to the aircraft structure. ...

  19. 14 CFR 33.83 - Vibration test.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Vibration test. 33.83 Section 33.83... STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.83 Vibration test. (a) Each engine must undergo vibration surveys to establish that the vibration characteristics of those components that...

  20. 14 CFR 33.33 - Vibration.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Vibration. 33.33 Section 33.33 Aeronautics... STANDARDS: AIRCRAFT ENGINES Design and Construction; Reciprocating Aircraft Engines § 33.33 Vibration. The... vibration and without imparting excessive vibration forces to the aircraft structure. ...

  1. 14 CFR 33.43 - Vibration test.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Vibration test. 33.43 Section 33.43... STANDARDS: AIRCRAFT ENGINES Block Tests; Reciprocating Aircraft Engines § 33.43 Vibration test. (a) Each engine must undergo a vibration survey to establish the torsional and bending vibration characteristics...

  2. 49 CFR 178.819 - Vibration test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Vibration test. 178.819 Section 178.819... Testing of IBCs § 178.819 Vibration test. (a) General. The vibration test must be conducted for the... vibration test. (b) Test method. (1) A sample IBC, selected at random, must be filled and closed as for...

  3. Rectangular Parallelepiped Vibration in Plane Strain State

    OpenAIRE

    Hanckowiak, Jerzy

    2004-01-01

    In this paper we present a vibration spectrum of a homogenous parallelepiped (HP) under the action of volume and surface forces resulting from the exponent displacements entering the Fourier transforms. Vibration under the action of axial surface tractions and the free vibration are described separately. A relationship between the high frequency vibration and boundary conditions (BC) is also considered.

  4. Emergency Response Capability Baseline Needs Assessment - Compliance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, John A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-09-01

    This document was prepared by John A. Sharry, LLNL Fire Marshal and Division Leader for Fire Protection and was reviewed by LLNL Emergency Management Department Head, James Colson. This document is the second of a two-part analysis on Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2016 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2016 BNA, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures. The 2013 BNA was approved by NNSA’s Livermore Field Office on January 22, 2014.

  5. Capability-based computer systems

    CERN Document Server

    Levy, Henry M

    2014-01-01

    Capability-Based Computer Systems focuses on computer programs and their capabilities. The text first elaborates capability- and object-based system concepts, including capability-based systems, object-based approach, and summary. The book then describes early descriptor architectures and explains the Burroughs B5000, Rice University Computer, and Basic Language Machine. The text also focuses on early capability architectures. Dennis and Van Horn's Supervisor; CAL-TSS System; MIT PDP-1 Timesharing System; and Chicago Magic Number Machine are discussed. The book then describes Plessey System 25

  6. Transforming organizational capabilities in strategizing

    DEFF Research Database (Denmark)

    Jørgensen, Claus; Friis, Ole Uhrskov; Koch, Christian

    2014-01-01

    Offshored and networked enterprises are becoming an important if not leading organizational form and this development seriously challenges their organizational capabilities. More specifically, over the last years, SMEs have commenced entering these kinds of arrangements. As the organizational...... capabilities of SMEs are limited at the outset, even more emphasis is needed regarding the issues of developing relevant organizational capabilities. This paper aims at investigating how capabilities evolve during an offshoring process of more than 5 years in two Danish SMEs, i.e. not only short- but long......-term evolvements within the companies. We develop our framework of understanding organizational capabilities drawing on dynamic capability, relational capability and strategy as practice concepts, appreciating the performative aspects of developing new routines. Our two cases are taken from one author’s Ph...

  7. Feature extraction and identification in distributed optical-fiber vibration sensing system for oil pipeline safety monitoring

    Science.gov (United States)

    Wu, Huijuan; Qian, Ya; Zhang, Wei; Tang, Chenghao

    2017-09-01

    High sensitivity of a distributed optical-fiber vibration sensing (DOVS) system based on the phase-sensitivity optical time domain reflectometry (Φ-OTDR) technology also brings in high nuisance alarm rates (NARs) in real applications. In this paper, feature extraction methods of wavelet decomposition (WD) and wavelet packet decomposition (WPD) are comparatively studied for three typical field testing signals, and an artificial neural network (ANN) is built for the event identification. The comparison results prove that the WPD performs a little better than the WD for the DOVS signal analysis and identification in oil pipeline safety monitoring. The identification rate can be improved up to 94.4%, and the nuisance alarm rate can be effectively controlled as low as 5.6% for the identification network with the wavelet packet energy distribution features.

  8. Feature extraction and identification in distributed optical-fiber vibration sensing system for oil pipeline safety monitoring

    Science.gov (United States)

    Wu, Huijuan; Qian, Ya; Zhang, Wei; Tang, Chenghao

    2017-12-01

    High sensitivity of a distributed optical-fiber vibration sensing (DOVS) system based on the phase-sensitivity optical time domain reflectometry (Φ-OTDR) technology also brings in high nuisance alarm rates (NARs) in real applications. In this paper, feature extraction methods of wavelet decomposition (WD) and wavelet packet decomposition (WPD) are comparatively studied for three typical field testing signals, and an artificial neural network (ANN) is built for the event identification. The comparison results prove that the WPD performs a little better than the WD for the DOVS signal analysis and identification in oil pipeline safety monitoring. The identification rate can be improved up to 94.4%, and the nuisance alarm rate can be effectively controlled as low as 5.6% for the identification network with the wavelet packet energy distribution features.

  9. Upper limb vibration prototype with sports and rehabilitation applications: development, evaluation and preliminary study.

    Science.gov (United States)

    Pujari, Amit Narahar; Neilson, Richard D; Aphale, Sumeet S; Cardinale, Marco

    2017-02-01

    Vibration stimulation as an exercise intervention has been studied increasingly for its potential benefits and applications in sports and rehabilitation. Vibratory exercise devices should be capable of generating highly precise and repeatable vibrations and should be capable of generating a range of vibration amplitudes and frequencies in order to provide different training protocols. Many devices used to exercise the upper body provide limited variations to exercise regimes mostly due to the fact that only vibration frequency can be controlled. The authors present an upper limb vibration exercise device with a novel actuator system and design which attempts to address these limitations. Preliminary results show that this device is capable of generating highly precise and repeatable vibrations with independent control over amplitude and frequency. Furthermore, the results also show that this solution provides a higher neuromuscular stimulation (i.e. electromyography activity) when compared with a control condition. The portability of this device is an advantage, and though in its current configuration it may not be suitable for applications requiring higher amplitude levels the technology is scalable.

  10. Vibrational Damping of Composite Materials

    OpenAIRE

    Biggerstaff, Janet M.

    2006-01-01

    The purpose of this research was to develop new methods of vibrational damping in polymeric composite materials along with expanding the knowledge of currently used vibrational damping methods. A new barrier layer technique that dramatically increased damping in viscoelastic damping materials that interacted with the composite resin was created. A method for testing the shear strength of damping materials cocured in composites was developed. Directional damping materials, where the loss facto...

  11. Vibration Theory, Vol. 1B

    DEFF Research Database (Denmark)

    Asmussen, J. C.; Nielsen, Søren R. K.

    The present collection of MATLAB exercises has been published as a supplement to the textbook, Svingningsteori, Bind 1 and the collection of exercises in Vibration theory, Vol. 1A, Solved Problems. Throughout the exercise references are made to these books. The purpose of the MATLAB exercises...... is to give a better understanding of the physical problems in linear vibration theory and to surpress the mathematical analysis used to solve the problems. For this purpose the MATLAB environment is excellent....

  12. Harmonic vibrations of multispan beams

    DEFF Research Database (Denmark)

    Dyrbye, Claes

    1996-01-01

    Free and forced harmonic vibrations of multispan beams are determined by a method which implies 1 equation regardless of the configuration. The necessary formulas are given in the paper. For beams with simple supports and the same length of all (n) spans, there is a rather big difference between...... the n´th and the (n+1)´th eigenfrequency. The reason for this phenomenon is explained.Keywords: Vibrations, Eigenfrequencies, Beams....

  13. Smart accelerometer. [vibration damage detection

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1994-01-01

    The invention discloses methods and apparatus for detecting vibrations from machines which indicate an impending malfunction for the purpose of preventing additional damage and allowing for an orderly shutdown or a change in mode of operation. The method and apparatus is especially suited for reliable operation in providing thruster control data concerning unstable vibration in an electrical environment which is typically noisy and in which unrecognized ground loops may exist.

  14. Improved Predictions for Geotechnical Vibrations

    OpenAIRE

    Macijauskas, Darius

    2015-01-01

    In urban areas where the infrastructure is dense and construction of new structures is near existing and sensitive buildings, frequently vibrations, caused by human activities, occur. Generated waves in the soil may adversely affect surrounding buildings. These vibrations have to be predicted a priori by using currently available knowledge of the soil dynamics. Current research, conducted by Deltares research institute, showed that the reliability of methods for prediction of m...

  15. Stress analysis of vibrating pipelines

    Science.gov (United States)

    Zachwieja, Janusz

    2017-03-01

    The pipelines are subject to various constraints variable in time. Those vibrations, if not monitored for amplitude and frequency, may result in both the fatigue damage in the pipeline profile at high stress concentration and the damage to the pipeline supports. If the constraint forces are known, the system response may be determined with high accuracy using analytical or numerical methods. In most cases, it may be difficult to determine the constraint parameters, since the industrial pipeline vibrations occur due to the dynamic effects of the medium in the pipeline. In that case, a vibration analysis is a suitable alternative method to determine the stress strain state in the pipeline profile. Monitoring the pipeline vibration levels involves a comparison between the measured vibration parameters and the permissible values as depicted in the graphs for a specific pipeline type. Unfortunately, in most cases, the studies relate to the petrochemical industry and thus large diameter, long and straight pipelines. For a pipeline section supported on both ends, the response in any profile at the entire section length can be determined by measuring the vibration parameters at two different profiles between the pipeline supports. For a straight pipeline section, the bending moments, variable in time, at the ends of the analysed section are a source of the pipe excitation. If a straight pipe section supported on both ends is excited by the bending moments in the support profile, the starting point for the stress analysis are the strains, determined from the Euler-Bernoulli equation. In practice, it is easier to determine the displacement using the experimental methods, since the factors causing vibrations are unknown. The industrial system pipelines, unlike the transfer pipelines, are straight sections at some points only, which makes it more difficult to formulate the equation of motion. In those cases, numerical methods can be used to determine stresses using the

  16. Impaired behavioural response to alarm substance in rainbow trout exposed to copper nanoparticles.

    Science.gov (United States)

    Sovová, Tereza; Boyle, David; Sloman, Katherine A; Vanegas Pérez, Cecilia; Handy, Richard D

    2014-07-01

    To date, studies of the toxicity of engineered nanoparticles (NPs) in fish have not fully considered effects on olfactory-mediated behaviours, despite their ecological importance. In this study the effects of copper NPs (Cu NPs) on the anti-predator behavioural responses of juvenile rainbow trout (Oncorhynchus mykiss) to trout alarm substance was investigated. Individual fish were exposed for 12h to a control (no added Cu), 50μgl(-1) of Cu as Cu NPs, or 50μgl(-1) Cu as CuSO4, after which fish behaviours were analyzed in 10min periods before and after the addition of the alarm substance stimulus. The response of control fish to deionised water (negative control, no alarm substance stimulus) was also analyzed. The alarm substance elicited a behavioural response in the control fish characterized by an immediate freeze response and the slower resumption of swimming activity compared to negative controls exposed to the sham deionised water stimuli. In fish exposed to Cu NPs, the behavioural response to alarm substance was eliminated, with no significant difference in behaviours compared to negative controls. In comparison, exposure to 50μgl(-1) Cu as CuSO4 decreased, but did not eliminate the response of fish to alarm substance, which indicated a significantly greater effect of Cu NPs on olfactory mediated behaviours than of the equivalent concentration of Cu as CuSO4. Measurement of total Cu concentrations in the tissues of fish demonstrated no significant accumulation of Cu from any treatment in gill, liver or brain, confirming the effects of Cu NPs, and to a lesser extent CuSO4, on behavioural responses were mostly associated with the interaction of the materials with the external surfaces of the fish. Scanning electron microscopy revealed that Cu as CuSO4 caused a pronounced depletion of ciliated sensory and non-sensory cells in the olfactory rosette surrounding the midline raphe, whereas Cu NPs had no impact on the structure of the rosette. However, exposure to

  17. Vibrational modes of nanolines

    Science.gov (United States)

    Heyliger, Paul R.; Flannery, Colm M.; Johnson, Ward L.

    2008-04-01

    Brillouin-light-scattering spectra previously have been shown to provide information on acoustic modes of polymeric lines fabricated by nanoimprint lithography. Finite-element methods for modeling such modes are presented here. These methods provide a theoretical framework for determining elastic constants and dimensions of nanolines from measured spectra in the low gigahertz range. To make the calculations feasible for future incorporation in inversion algorithms, two approximations of the boundary conditions are employed in the calculations: the rigidity of the nanoline/substrate interface and sinusoidal variation of displacements along the nanoline length. The accuracy of these approximations is evaluated as a function of wavenumber and frequency. The great advantage of finite-element methods over other methods previously employed for nanolines is the ability to model any cross-sectional geometry. Dispersion curves and displacement patterns are calculated for modes of polymethyl methacrylate nanolines with cross-sectional dimensions of 65 nm × 140 nm and rectangular or semicircular tops. The vibrational displacements and dispersion curves are qualitatively similar for the two geometries and include a series of flexural, Rayleigh-like, and Sezawa-like modes. This paper is a contribution of the National Institute of Standards and Technology and is not subject to copyright in the United States.

  18. Blade Vibration Measurement System for Unducted Fans

    Science.gov (United States)

    Marscher, William

    2014-01-01

    With propulsion research programs focused on new levels of efficiency and noise reduction, two avenues for advanced gas turbine technology are emerging: the geared turbofan and ultrahigh bypass ratio fan engines. Both of these candidates are being pursued as collaborative research projects between NASA and the engine manufacturers. The high bypass concept from GE Aviation is an unducted fan that features a bypass ratio of over 30 along with the accompanying benefits in fuel efficiency. This project improved the test and measurement capabilities of the unducted fan blade dynamic response. In the course of this project, Mechanical Solutions, Inc. (MSI) collaborated with GE Aviation to (1) define the requirements for fan blade measurements; (2) leverage MSI's radar-based system for compressor and turbine blade monitoring; and (3) develop, validate, and deliver a noncontacting blade vibration measurement system for unducted fans.

  19. The song remains the same: Juvenile Richardson's ground squirrels do not respond differentially to mother's or colony member's alarm calls

    Directory of Open Access Journals (Sweden)

    James F. HARE, Kurtis J. WARKENTIN

    2012-10-01

    Full Text Available Alarm calls are emitted by Richardson's ground squirrels Urocitellus richardsonii in response to avian and terrestrial predators. Conspecifics detecting these calls respond with increased vigilance, promoting predator detection and evasion, but in doing so, lose time from foraging. That loss can be minimized if alarm call recipients discriminate among signalers, and weight their response accordingly. For juvenile ground squirrels, we predicted that the trade-off between foraging and vigilance could be optimized via selective response to alarm calls emitted by their own dam, and/or neighboring colony members over calls broadcast by less familiar conspecifics. Alarm calls of adult female Richardson's ground squirrels were elicited in the field using a predator model and recorded on digital audio tape. Free-living focal juveniles were subjected to playbacks of a call of their mother, and on a separate occasion a call from either another adult female from their own colony, or an adult female from another colony. Neither immediate postural responses and escape behavior, nor the duration of vigilance manifested by juveniles differed with exposure to alarm calls of the three adult female signaler types. Thus, juveniles did not respond preferentially to alarm calls emitted by their mothers or colony members, likely reflecting the high cost of ignoring alarm signals where receivers have had limited opportunity to establish past signaler reliability [Current Zoology 58 (5: 773–780, 2012].

  20. Design of DroDeASys (Drowsy Detection and Alarming System)

    Science.gov (United States)

    Juvale, Hrishikesh B.; Mahajan, Anant S.; Bhagwat, Ashwin A.; Badiger, Vishal T.; Bhutkar, Ganesh D.; Dhabe, Priyadarshan S.; Dhore, Manikrao L.

    The paper discusses the Drowsy Detection & Alarming System that has been developed, using a non-intrusive approach. The system is basically developed to detect drivers dozing at the wheel at night time driving. The system uses a small infra-red night vision camera that points directly towards the driver`s face and monitors the driver`s eyes in order to detect fatigue. In such a case when fatigue is detected, a warning signal is issued to alert the driver. This paper discusses the algorithms that have been used to detect drowsiness. The decision whether the driver is dozing or not is taken depending on whether the eyes are open for a specific number of frames. If the eyes are found to be closed for a certain number of consecutive frames then the driver is alerted with an alarm.

  1. Wolbachia-Free Heteropterans Do Not Produce Defensive Chemicals or Alarm Pheromones.

    Science.gov (United States)

    Becerra, Judith X; Venable, Gabriela X; Saeidi, Vahid

    2015-07-01

    The true bugs, or heteropterans, are known for their widespread production of anti-predator chemicals and alarm pheromones in scent glands, a derived trait that constitutes one of the defining characters of the suborder Heteroptera and a potential novel trait that contributed to their diversification. We investigated whether symbiotic bacteria could be involved in the formation of these chemicals using Thasus neocalifornicus, a coreid bug that produces semiochemicals frequently found in other bugs. Using DNA phylogenetic methodology and experiments using antibiotics coupled with molecular techniques, we identified Wolbachia as the microorganism infecting the scent glands of this bug. Decreasing the level of Wobachia infection using antibiotics was correlated with a diminution of heteropteran production of defensive compounds and alarm pheromones, suggesting that this symbiotic bacterium might be implicated in the formation of chemicals.

  2. Distributed error and alarm processing in the CMS data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, G.; et al.

    2012-01-01

    The error and alarm system for the data acquisition of the Compact Muon Solenoid (CMS) at CERN was successfully used for the physics runs at Large Hadron Collider (LHC) during first three years of activities. Error and alarm processing entails the notification, collection, storing and visualization of all exceptional conditions occurring in the highly distributed CMS online system using a uniform scheme. Alerts and reports are shown on-line by web application facilities that map them to graphical models of the system as defined by the user. A persistency service keeps a history of all exceptions occurred, allowing subsequent retrieval of user defined time windows of events for later playback or analysis. This paper describes the architecture and the technologies used and deals with operational aspects during the first years of LHC operation. In particular we focus on performance, stability, and integration with the CMS sub-detectors.

  3. Male blue monkeys alarm call in response to danger experienced by others

    DEFF Research Database (Denmark)

    Papworth, Sarah; Böse, Anne-Sophie; Barker, Jessie

    2008-01-01

    Male blue monkeys (Cercopithecus mitis stuhlmanni) of Budongo Forest, Uganda, produce two acoustically distinct alarm calls: hacks to crowned eagles (Stephanoaetus coronatus) and pyows to leopards (Panthera pardus) and a range of other disturbances. In playback experiments, males responded...... to leopard growls exclusively with a series of pyows and to eagle shrieks predominantly with hacks. Responses to playbacks of these alarm call series matched the responses to the corresponding predators, suggesting that the calls conveyed something about the nature of the threat. When responding to a series...... of hacks, indicating an eagle, males responded predominately with hacks, but produced significantly more calls if their group members were close to the playback stimulus than far away, regardless of their own position. When responding to a series of pyows, indicating a range of disturbances, males...

  4. Distributed error and alarm processing in the CMS data acquisition system

    CERN Document Server

    Bauer, Gerry; Bowen, Matthew; Branson, James; Bukowiec, Sebastian Czeslaw; Cittolin, Sergio; Coarasa, J A; Deldicque, Christian; Dobson, Marc; Dupont, Aymeric; Erhan, Samim; Flossdorf, Alexander; Gigi, Dominique; Glege, Frank; Gomez-Reino, R; Hartl, Christian; Hegeman, Jeroen Guido; Holzner, Andre Georg; Hwong, Yi Ling; Masetti, Lorenzo; Meijers, Franciscus; Meschi, Emilio; Mommsen, Remigius; O'Dell, Vivian; Orsini, Luciano; Paus, Christoph Maria Ernst; Petrucci, Andrea; Pieri, Marco; Polese, Giovanni; Racz, Attila; Raginel, Olivier; Sakulin, Hannes; Sani, Matteo; Schwick, Christoph; Shpakov, Denis; Simon, M; Spataru, Andrei Cristian; Sumorok, Konstanty

    2012-01-01

    The error and alarm system for the data acquisition of the Compact Muon Solenoid (CMS) at CERN was successfully used for the physics runs at Large Hadron Collider (LHC) during first three years of activities. Error and alarm processing entails the notification, collection, storing and visualization of all exceptional conditions occurring in the highly distributed CMS online system using a uniform scheme. Alerts and reports are shown on\\-line by web application facilities that map them to graphical models of the system as defined by the user. A persistency service keeps a history of all exceptions occurred, allowing subsequent retrieval of user defined time windows of events for later playback or analysis. This paper describes the architecture and the technologies used and deals with operational aspects during the first years of LHC operation. In particular we focus on performance, stability, and integration with the CMS sub\\-detectors.

  5. The Wireless Environment Monitoring Alarm System Based on Self-organizing Network

    Directory of Open Access Journals (Sweden)

    Zhang Huawei

    2016-01-01

    Full Text Available Under complicated conditions, it is necessary for environmental monitoring to design a wireless monitoring alarm system which can replace the wired system or as a supplement. The system discussed here bases on ARM7 microprocessor named LPC1114 and transceiver module named CC2530. With ZigBee, CSM/GPRS, this system uses multiple sensors to self-organized form a data acquisition and monitoring network system with variety of sensors fusion in the region. The system has some characteristics such as quick, convenient and accurate. Combining with the GSM SMS or GPRS alarm, the system can accurately and reliably monitor temperature, humidity and other environmental factors, and realize remote monitoring in large area and the complicated environment. Thus, this system has high practical value.

  6. Triggering radiation alarm at security checks. Patients should be informed even after diagnostic nuclear medicine procedures.

    Science.gov (United States)

    Palumbo, Barbara; Neumann, Irmgard; Havlik, Ernst; Palumbo, Renato; Sinzinger, Helmut

    2009-01-01

    During the last few years an increasing number of nuclear medicine patients in various countries evoked a radiation alarm after therapeutic or diagnostic procedures, and even after passive exposure. A prospective calculation of activity retention in the patient's body is difficult due to extremely high variation of uptake and kinetics. Furthermore, different sensitivities and distances of the detectors make a prospective calculation even more difficult. In this article a number of cases are being reported, related problems are discussed and the surprisingly very limited literature reviewed. In order to minimize problems after eventually triggering alarms, we strongly recommend that each patient receives a certificate providing personal data, tracer, dose, half-life of the radionuclide, type and date of procedure applied as well as the nuclear medicine unit to contact for further information. Furthermore, a closer cooperation and exchange of information between the authorities and local nuclear medicine societies, would be welcome.

  7. Monitoring techniques and alarm procedures for CMS services and sites in WLCG

    CERN Document Server

    Molina-Perez, Jorge Amando

    2012-01-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS; the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator on duty at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is explo...

  8. Lifestyle factors and contact to general practice with respiratory alarm symptoms

    DEFF Research Database (Denmark)

    Sele, Lisa Maria Falk; Elnegaard, Sandra; Balasubramaniam, Kirubakaran

    2016-01-01

    , and lifestyle factors (smoking status, alcohol intake, and body mass index) were included. RESULTS: In total 49 706 (52.5 %) individuals answered the questionnaire. Overall 7870 reported at least one respiratory alarm symptom, and of those 39.6 % (3 080) had contacted a GP. Regarding specific symptoms......BACKGROUND: A prerequisite for early lung cancer diagnosis is that individuals with respiratory alarm symptoms (RAS) contact a general practitioner (GP). This study aims to determine the proportion of individuals in the general population who contact a GP with RAS and to analyse the association...... between lifestyle factors and contact to GPs with RAS. METHODS: A web-based survey of 100 000 individuals randomly selected from the Danish Civil Registration System. Items regarding experience of RAS (prolonged coughing, shortness of breath, coughing up blood, and prolonged hoarseness), GP contacts...

  9. Conspecific and heterospecific alarm substances induce behavioral responses in juvenile catfish Rhamdia quelen

    Directory of Open Access Journals (Sweden)

    Carina Vogel

    2017-04-01

    Full Text Available ABSTRACT The recognition of chemical information indicating the presence of a predator is very important for prey survival. In this study we tested antipredator behavioral response of juvenile silver catfish (Rhamdia quelen against predator odor released by two different potential predators, Hoplias malabaricus and the snake Helicops infrataeniatus, and alarm cues and disturbance cues released by conspecifics and by non-predator species, Megaleporinus obtusidens and Astyanax lacustris. We used juvenile catfish that were naive to predators. The trials consisted of a 10-min prestimulus and a 10-min post-stimulus observation period. The behavioral response displayed by silver catfish exposed to alarm cues comprised a decrease in shelter use and an increase in locomotion, and also a longer latency period before feeding. Our results showed that juvenile silver catfish can perceive chemical cues released by predators, heterospecifics and conspecifics.

  10. Microgravity Active Vibration Isolation System on Parabolic Flights

    Science.gov (United States)

    Dong, Wenbo; Pletser, Vladimir; Yang, Yang

    2016-07-01

    The Microgravity Active Vibration Isolation System (MAIS) aims at reducing on-orbit vibrations, providing a better controlled lower gravity environment for microgravity physical science experiments. The MAIS will be launched on Tianzhou-1, the first cargo ship of the China Manned Space Program. The principle of the MAIS is to suspend with electro-magnetic actuators a scientific payload, isolating it from the vibrating stator. The MAIS's vibration isolation capability is frequency-dependent and a decrease of vibration of about 40dB can be attained. The MAIS can accommodate 20kg of scientific payload or sample unit, and provide 30W of power and 1Mbps of data transmission. The MAIS is developed to support microgravity scientific experiments on manned platforms in low earth orbit, in order to meet the scientific requirements for fluid physics, materials science, and fundamental physics investigations, which usually need a very quiet environment, increasing their chances of success and their scientific outcomes. The results of scientific experiments and technology tests obtained with the MAIS will be used to improve future space based research. As the suspension force acting on the payload is very small, the MAIS can only be operative and tested in a weightless environment. The 'Deutsches Zentrum für Luft- und Raumfahrt e.V.' (DLR, German Aerospace Centre) granted a flight opportunity to the MAIS experiment to be tested during its 27th parabolic flight campaign of September 2015 performed on the A310 ZERO-G aircraft managed by the French company Novespace, a subsidiary of the 'Centre National d'Etudes Spatiales' (CNES, French Space Agency). The experiment results confirmed that the 6 degrees of freedom motion control technique was effective, and that the vibration isolation performance fulfilled perfectly the expectations based on theoretical analyses and simulations. This paper will present the design of the MAIS and the experiment results obtained during the

  11. Performance of the Species-Typical Alarm Response in Young Workers of the Ant Myrmica sabuleti (Hymenoptera: Formicidae) Is Induced by Interactions with Mature Workers

    OpenAIRE

    Cammaerts, Marie-Claire

    2014-01-01

    Young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) Meinert 1861 perceived nestmate alarm pheromone but did not display normal alarm behavior (orientation toward the source of emission, increased running speed). They changed their initial behavior when in the presence of older nestmates exhibiting normal alarm behavior. Four days later, the young ants exhibited an imperfect version of normal alarm behavior. This change of behavior did not occur in young ants, which were not ex...

  12. Developing Collaborative Product Development Capabilities

    DEFF Research Database (Denmark)

    Mahnke, Volker; Tran, Yen

    2012-01-01

    innovation strategies’. Our analyses suggest that developing such collaboration capabilities benefits from the search for complementary practices, the combination of learning styles, and the development of weak and strong ties. Results also underscore the crucial importance of co-evolution of multi......-level, simultaneous learning processes and highlight the role of human agency in capability development with partners. Building on our analyses, we advance propositions for future research and managerial practices on developing dynamic collaboration capabilities....

  13. Nurses' response to frequency and types of electrocardiography alarms in a non-critical care setting: a descriptive study.

    Science.gov (United States)

    Gazarian, Priscilla K

    2014-02-01

    An important role of the registered nurse is to identify patient deterioration by monitoring the patient condition and vital signs. Increasingly, this is supplemented with continuous electrocardiographic (ECG) monitoring. Continuous monitoring is inefficient in identifying deterioration because of the high number of false and nuisance alarms. Lack of strong evidence or formal guidelines for the care of patients receiving ECG monitoring has led clinicians to rely too heavily on this technology without consideration of its limitations. The nursing workload associated with alarm management remains unexamined. To describe nurses' routine practices related to continuous ECG monitoring, frequency and types of alarms, their associated nursing interventions, and the impact on the patient's plan of care. Design. Prospective, descriptive, observational study. Setting and participants. Between January 2011 and March 2011 we observed nine Registered Nurses providing care for patients receiving continuous ECG monitoring in non-critical care areas. The PI and two research assistants observed each nurse for two 3-h observation periods and recorded data on a researcher designed observation tool. At the end of each observation period, the observers printed the alarm events as recorded by the central monitoring computer. Nurses responded to 46.8% of all alarms. During the observation period, there were no dysrhythmia adverse events. One patient had a change in condition requiring transfer to a higher level of care. A range of nursing interventions occurred in response to alarms. Nurses routine practices related to monitoring continue to reveal gaps in practice related to alarm management. Observations of practice also revealed the difficulties and complexities of managing alarm systems and the range of nursing interventions associated with managing alarms. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Alarming Signs and Symptoms in Febrile Children in Primary Care: An Observational Cohort Study in The Netherlands

    Science.gov (United States)

    Bohnen, Arthur M.; de Wilde, Marcel; Moll, Henriëtte A.; Oostenbrink, Rianne; Berger, Marjolein Y.

    2014-01-01

    Context Febrile children in primary care have a low risk for serious infection. Although several alarming signs and symptoms are proposed to have predictive value for serious infections, most are based on research in secondary care. The frequency of alarming signs/symptoms has not been established in primary care; however, in this setting differences in occurrence may influence their predictive value for serious infections. Objective To determine the frequency of alarming signs/symptoms in febrile children in primary care. Design Observational cohort study. Clinical information was registered in a semi-structured way and manually recoded. Setting General practitioners' out-of-hours service. Subjects Face-to-face patient contacts concerning children (aged ≤16 years) with fever were eligible for inclusion. Main outcome measures Frequency of 18 alarming signs and symptoms as reported in the literature. Results A total of 10,476 patient contacts were included. The frequency of alarming signs/symptoms ranged from n = 1 (ABC instability; signs and/or symptoms. Several alarming signs/symptoms were poorly registered with the frequency of missing information ranging from 1,347 contacts (temperature >40°C as reported by the parents; 12.9%) to 8,647 contacts (parental concern; 82.5%). Conclusion Although the prevalence of specific alarming signs/symptoms is low in primary care, ≥50% of children have one or more alarming signs/symptoms. There is a need to determine the predictive value of alarming signs/symptoms not only for serious infections in primary care, but as well for increased risk of a complicated course of the illness. PMID:24586305

  15. Safety Bulletin 2013-1: When the alarm rings, you must leave!

    CERN Multimedia

    HSE Unit

    2013-01-01

    The HSE Unit just released the Safety Bulletin 2013-1 entitled “When the alarm rings, you must leave!”. The Bulletin is available on EDMS under the following number: 1307611. Be reminded  that HSE Safety Bulletins are published in English and French and share feedbacks of incidents/near miss/accidents that happened on the CERN site with the aim to improve prevention.

  16. Heart rate variability during "alarm stage" of burnout syndrome in emergency doctors.

    Science.gov (United States)

    Kotov, A V; Revina, N E

    2012-09-01

    The parameters of heart rate variations were examined in emergency care doctors that demonstrated the initial signs of defensive psychological burnout syndrome related to their professional activity. These parameters were compared within each of two groups with different individual typological features. The differences in the heart rate variability parameters were revealed between the examinees that were at the compensation or alarm stages of the burnout syndrome.

  17. Alarm pheromone habituation in Myzus persicae has fitness consequences and causes extensive gene expression changes.

    Science.gov (United States)

    de Vos, Martin; Cheng, Wing Yin; Summers, Holly E; Raguso, Robert A; Jander, Georg

    2010-08-17

    In most aphid species, facultative parthenogenetic reproduction allows rapid growth and formation of large single-genotype colonies. Upon predator attack, individual aphids emit an alarm pheromone to warn the colony of this danger. (E)-beta-farnesene (EBF) is the predominant constituent of the alarm pheromone in Myzus persicae (green peach aphid) and many other aphid species. Continuous exposure to alarm pheromone in aphid colonies raised on transgenic Arabidopsis thaliana plants that produce EBF leads to habituation within three generations. Whereas naive aphids are repelled by EBF, habituated aphids show no avoidance response. Similarly, individual aphids from the habituated colony can revert back to being EBF-sensitive in three generations, indicating that this behavioral change is not caused by a genetic mutation. Instead, DNA microarray experiments comparing gene expression in naive and habituated aphids treated with EBF demonstrate an almost complete desensitization in the transcriptional response to EBF. Furthermore, EBF-habituated aphids show increased progeny production relative to EBF-responsive aphids, with or without EBF treatment. Although both naive and habituated aphids emit EBF upon damage, EBF-responsive aphids have a higher survival rate in the presence of a coccinellid predator (Hippodamia convergens), and thus outperform habituated aphids that do not show an avoidance response. These results provide evidence that aphid perception of conspecific alarm pheromone aids in predator avoidance and thereby bestows fitness benefits in survivorship and fecundity. Therefore, although habituated M. persicae produce more progeny, EBF-emitting transgenic plants may have practical applications in agriculture as a result of increased predation of habituated aphids.

  18. Recurrent abdominal pain in children: underlying pathologies in the absence of "alarm" symptoms.

    Science.gov (United States)

    Tolone, Carlo; Pellino, Valeria; Piccirillo, Margherita; Letizia, Mariarosaria; Belfiore, Ivano; Tolone, Salvatore

    2017-08-01

    Recurrent abdominal pain (RAP) is a common disorder in childhood. However, it is not clear what the incidence of organic disease is, in the absence of "alarm" symptoms or signs. The aim of this study was to clarify if the performance of diagnostic tests can be useful in revealing underlying organic disorders. The participants were 4- to 16-year-old children, who had been referred to our tertiary care pediatric center. A total of 98 children (48 males, 50 females) with RAP but without any alarm symptoms or signs were selected. In the 98 selected children, the performance of diagnostic tests for suspected organic diseases was recommended. Fourteen children refused diagnostic tests. Forty-eight out of 84 children with RAP without any alarm symptoms and signs received a diagnosis of organic disease. Nineteen (22.6%) patients resulted positive for lactose intolerance. Seventeen patients (20.2%) were affected by celiac disease. Two (2.4%) patients were positive for cow milk allergy. Nine (10.7%) patients resulted positive for ureteral calculosis. One (1.2%) was affected by teniasis. Thirty-three children of the 38 children tested positive for lactose intolerance, celiac disease or cow-milk allergy were completely symptom-free at the 6 months follow-up and the remaining five patients reported a significant lower mean level of pain severity overall. Seven of 9 children with calculosis improved symptomatology. At the next follow-up six children were again suffering from RAP. Children with RAP should be referred to pediatric gastroenterologists if symptoms persist; testing should be performed even in the absence of alarm signs because of the high prevalence of underlying organic pathologies.

  19. Technical aspects of the sigma factor alarm method in alpha CAMs

    Energy Technology Data Exchange (ETDEWEB)

    Justus, Alan Lawrence [Los Alamos National Laboratory

    2009-01-01

    Some test must be applied to the low-level count data from alpha continuous air monitors (CAMs) to determine if the count is statistically significant (i.e., different from background). The test should also automatically account for different levels of background (i.e., ambient radon progeny concentrations). The method should, in other words, be as sensitive as possible, automatically desensitize when required, but in such a manner as to not exceed a previously-chosen acceptable false-alarm rate.

  20. Evaluation of hand-arm vibration reducing effect of anti-vibration glove

    OpenAIRE

    樹野, 淳也; 前田, 節雄; 横田, 和樹; 平, 雄一郎

    2015-01-01

    Many kinds of the anti-vibration glove have been developed for reducing hand-arm vibration during the operation with vibration tools. International standard ISO 10819 evaluates the physical effect of gloves' vibration transmissibility but not evaluates the physiological effect of human hands. Thus, in this paper, we proposed the evaluation using the temporary threshold shift of vibrotactile perception threshold to evaluate the hand-arm vibration reducing effect of anti-vibration glove. We per...

  1. Alarm analysis

    Energy Technology Data Exchange (ETDEWEB)

    Esp, D.G.; Warwick, K.

    1997-12-31

    The electrical power distribution network in the UK is a distributed grid of high power components. The grid is controlled hierarchically with, at the lower level, proximal components being grouped around substations which contain not only protection elements but also sequencing and timing logic. At the next level up the substations feed to a control centre which, for historical reasons, can be viewed in terms of a number of different geographical areas, each area control containing its own regional substations. When a fault occurs on the transmission network, automatic protection and isolation occurs at a number of substations, opening switches to ensure that power is no longer fed to the faulty line, and that the disturbance on the remainder of the grid is effectively minimised. Details on which of the switches have operated are passed on to the control centre which continually polls round the different substations to see what switchgear information each has. No direct information is obtained on what type of fault has occurred and where, but rather information is obtained in the control centre which indicates whch switches and automatic protection devices have operated in response to the fault. (Author)

  2. Antipredator and alarm reaction responses of silver catfish (Rhamdia quelen juveniles exposed to waterborne ammonia

    Directory of Open Access Journals (Sweden)

    Paula Weber

    Full Text Available Ammonia has relatively toxic effects on fish and other aquatic organisms. This study examined whether juvenile silver catfish exposed to alarm substances released by conspecifics and predators in water with different ammonia levels modify their behaviour in response to the perceived risk of predation. We used juvenile catfish that were naive to predators. The fish were raised from the larval stage in the laboratory and kept in 40-L aquaria at waterborne NH3 concentrations of 0, 0.05, 0.1, or 0.2 mg L-1 for 10 days. The alarm substances used were predator odour and skin extract from conspecifics. The juveniles were transferred to 2-L aquaria for the antipredator and alarm reaction behavioural tests, which were performed on days 1, 5 and 10 after initial exposure to ammonia. The test aquaria contained a shelter at one end of the tank. The trials consisted of a 10-min prestimulus and a 10-min poststimulus observation period. The results of the study suggest that naive juvenile catfish are able to identify predators and skin extract from conspecifics by odour. In addition, waterborne NH3 levels modify the antipredator response of this species.

  3. A dispersed alarm system for the elderly and its relevance to local general practitioners

    Science.gov (United States)

    McWhirter, Malcolm

    1987-01-01

    This paper describes the use of a dispersed alarm system for the elderly in the Central region of Scotland. Information from referral forms, questionnaires completed by wardens after a call and client registers were used to investigate the population served, sources of referral and the way the service was used. All the general practitioners working in the area covered by the service were sent a questionnaire asking for their views of the service. In May 1984 the alarm system covered 861 clients in private housing and 1259 in sheltered housing. Over 50% of referrals were from the health services and the most common reasons for referral were poor mobility and falls. False alarms accounted for 40% of calls and they were more likely to be from clients in sheltered housing than in private housing. Of genuine calls 71% were due to illness or disability with 25% due to falls. All of the general practitioners responding to the questionnaire were aware of a patient in their practice covered by the service and considered that the service provided useful 24-hour support for the elderly at risk because of frailty and disability PMID:3448211

  4. Aphid alarm pheromone as a cue for ants to locate aphid partners.

    Directory of Open Access Journals (Sweden)

    François J Verheggen

    Full Text Available The mutualistic relationships that occur between myrmecophilous aphids and ants are based on the rich food supply that honeydew represents for ants and on the protection they provide against aphid natural enemies. While aphid predators and parasitoids actively forage for oviposition sites by using aphid semiochemicals, scouts of aphid-tending ant species would also benefit from locating honeydew resources by orienting toward aphid pheromone sources. The present study aims to provide additional information on the use of Aphis fabae alarm pheromone, i.e. (E-β-farnesene (EβF, by ant scouts. The perception and behavioral impact of EβF on Lasius niger were investigated using electroantennography and two bio-assays measuring their attraction and orientation towards aphid semiochemicals. Pronounced electrical depolarizations were observed from L. niger scout antennae to stimulations of A. fabae alarm pheromone, while other sesquiterpenes elicited weak or no responses. L. niger scouts were significantly attracted toward EβF in a four-arm olfactometer, as well as in an two-choice bioassay. These laboratory results suggest for the first time that low amounts of aphid alarm pheromone can be used by L. niger scouts as a cue indicating the presence of aphid colonies and could therefore mediate the aphid-ant partnership in the field.

  5. Neural correlates underlying naloxone-induced amelioration of sexual behavior deterioration due to an alarm pheromone

    Directory of Open Access Journals (Sweden)

    Tatsuya eKobayashi

    2015-02-01

    Full Text Available Sexual behavior is suppressed by various types of stressors. We previously demonstrated that an alarm pheromone released by stressed male Wistar rats is a stressor to other rats, increases the number of mounts needed for ejaculation, and decreases the hit rate (described as the number of intromissions/sum of the mounts and intromissions. This deterioration in sexual behavior was ameliorated by pretreatment with the opioid receptor antagonist naloxone. However, the neural mechanism underlying this remains to be elucidated. Here, we examined Fos expression in 31 brain regions of pheromone-exposed rats and naloxone-pretreated pheromone-exposed rats 60 min after 10 intromissions. As previously reported, the alarm pheromone increased the number of mounts and decreased the hit rate. In addition, Fos expression was increases in the anterior medial division, anterior lateral division and posterior division of the bed nucleus of the stria terminalis, parvocellular part of the paraventricular nucleus of the hypothalamus, arcuate nucleus, dorsolateral and ventrolateral periaqueductal gray, and nucleus paragigantocellularis. Fos expression decreased in the magnocellular part of the paraventricular nucleus of the hypothalamus. Pretreatment with naloxone blocked the pheromone-induced changes in Fos expression in the magnocellular part of the paraventricular nucleus of the hypothalamus, ventrolateral periaqueductal gray, and nucleus paragigantocellularis. Based on these results, we hypothesize that the alarm pheromone deteriorated sexual behavior by activating the ventrolateral periaqueductal gray-nucleus paragigantocellularis cluster and suppressing the magnocellular part of the paraventricular nucleus of the hypothalamus via the opioidergic pathway.

  6. A WSN-Based Intrusion Alarm System to Improve Safety in Road Work Zones

    Directory of Open Access Journals (Sweden)

    Jose Martin

    2016-01-01

    Full Text Available Road traffic accidents are one of the main causes of death and disability worldwide. Workers responsible for maintaining and repairing roadways are especially prone to suffer these events, given their exceptional exposure to traffic. Since these actuations usually coexist with regular traffic, an errant driver can easily intrude the work area and provoke a collision. Some authors have proposed mechanisms aimed at detecting breaches in the work zone perimeter and alerting workers, which are collectively called intrusion alarm systems. However, they have several limitations and have not yet fulfilled the necessities of these scenarios. In this paper, we propose a new intrusion alarm system based on a Wireless Sensor Network (WSN. Our system is comprised of two main elements: vehicle detectors that form a virtual barrier and detect perimeter breaches by means of an ultrasonic beam and individual warning devices that transmit alerts to the workers. All these elements have a wireless communication interface and form a network that covers the whole work area. This network is in charge of transmitting and routing the alarms and coordinates the behavior of the system. We have tested our solution under real conditions with satisfactory results.

  7. Alarm calls evoke a visual search image of a predator in birds.

    Science.gov (United States)

    Suzuki, Toshitaka N

    2018-01-29

    One of the core features of human speech is that words cause listeners to retrieve corresponding visual mental images. However, whether vocalizations similarly evoke mental images in animal communication systems is surprisingly unknown. Japanese tits (Parus minor) produce specific alarm calls when and only when encountering a predatory snake. Here, I show that simply hearing these calls causes tits to become more visually perceptive to objects resembling snakes. During playback of snake-specific alarm calls, tits approach a wooden stick being moved in a snake-like fashion. However, tits do not respond to the same stick when hearing other call types or if the stick's movement is dissimilar to that of a snake. Thus, before detecting a real snake, tits retrieve its visual image from snake-specific alarm calls and use this to search out snakes. This study provides evidence for a call-evoked visual search image in a nonhuman animal, offering a paradigm to explore the cognitive basis for animal vocal communication in the wild.

  8. Estimating Alarm Thresholds for Process Monitoring Data under Different Assumptions about the Data Generating Mechanism

    Directory of Open Access Journals (Sweden)

    Tom Burr

    2013-01-01

    Full Text Available Process monitoring (PM for nuclear safeguards sometimes requires estimation of thresholds corresponding to small false alarm rates. Threshold estimation dates to the 1920s with the Shewhart control chart; however, because possible new roles for PM are being evaluated in nuclear safeguards, it is timely to consider modern model selection options in the context of threshold estimation. One of the possible new PM roles involves PM residuals, where a residual is defined as residual = data − prediction. This paper reviews alarm threshold estimation, introduces model selection options, and considers a range of assumptions regarding the data-generating mechanism for PM residuals. Two PM examples from nuclear safeguards are included to motivate the need for alarm threshold estimation. The first example involves mixtures of probability distributions that arise in solution monitoring, which is a common type of PM. The second example involves periodic partial cleanout of in-process inventory, leading to challenging structure in the time series of PM residuals.

  9. Human gender differences in the perception of conspecific alarm chemosensory cues.

    Directory of Open Access Journals (Sweden)

    Anca R Radulescu

    Full Text Available It has previously been established that, in threatening situations, animals use alarm pheromones to communicate danger. There is emerging evidence of analogous chemosensory "stress" cues in humans. For this study, we collected alarm and exercise sweat from "donors," extracted it, pooled it and presented it to 16 unrelated "detector" subjects undergoing fMRI. The fMRI protocol consisted of four stimulus runs, with each combination of stimulus condition and donor gender represented four times. Because olfactory stimuli do not follow the canonical hemodynamic response, we used a model-free approach. We performed minimal preprocessing and worked directly with block-average time series and step-function estimates. We found that, while male stress sweat produced a comparably strong emotional response in both detector genders, female stress sweat produced a markedly stronger arousal in female than in male detectors. Our statistical tests pinpointed this gender-specificity to the right amygdala (strongest in the superficial nuclei. When comparing the olfactory bulb responses to the corresponding stimuli, we found no significant differences between male and female detectors. These imaging results complement existing behavioral evidence, by identifying whether gender differences in response to alarm chemosignals are initiated at the perceptual versus emotional level. Since we found no significant differences in the olfactory bulb (primary processing site for chemosensory signals in mammals, we infer that the specificity in responding to female fear is likely based on processing meaning, rather than strength, of chemosensory cues from each gender.

  10. The Performance of Earthworm Based Earthquake Alarm Reporting System in Taiwan

    Science.gov (United States)

    Chen, Ta-Yi; Hsiao, Nai-Chi; Wu, Yih-Min

    2016-04-01

    The Central Weather Bureau of Taiwan has operated an earthquake early warning (EEW) system and issued warnings to schools and government agencies since 2014. Because the real-time seismic data streams are integrated by the Earthworm software, some EEW modules were created under the Earthworm platform. The system is named Earthworm Based Earthquake Alarm Reporting (eBEAR) system, which is currently operating. The eBEAR system consists of new Earthworm modules for managing P-wave phase picking, trigger associations, hypocenter locations, magnitude estimations, and alert filtering prior to broadcasting. Here, we outline the methodology and performance of the eBEAR system. The online performance of the eBEAR system indicated that the average reporting times afforded by the system are approximately 15 and 26 s for inland and offshore earthquakes, respectively. Comparing to the earthquake catalog, the difference of the epicenters are less than 10 km for inland earthquakes; the difference of the magnitude are about 0.3. No false alarms generated by the system, but there were three false alarms issued by human. Due to the wrong operations, the EEW information created by off-line test were sent. However, we have learned from it and improved the standard operation procedure in the EEW system.

  11. Early warning, warning or alarm systems for natural hazards? A generic classification.

    Science.gov (United States)

    Sättele, Martina; Bründl, Michael; Straub, Daniel

    2013-04-01

    Early warning, warning and alarm systems have gained popularity in recent years as cost-efficient measures for dangerous natural hazard processes such as floods, storms, rock and snow avalanches, debris flows, rock and ice falls, landslides, flash floods, glacier lake outburst floods, forest fires and even earthquakes. These systems can generate information before an event causes loss of property and life. In this way, they mainly mitigate the overall risk by reducing the presence probability of endangered objects. These systems are typically prototypes tailored to specific project needs. Despite their importance there is no recognised system classification. This contribution classifies warning and alarm systems into three classes: i) threshold systems, ii) expert systems and iii) model-based expert systems. The result is a generic classification, which takes the characteristics of the natural hazard process itself and the related monitoring possibilities into account. The choice of the monitoring parameters directly determines the system's lead time. The classification of 52 active systems moreover revealed typical system characteristics for each system class. i) Threshold systems monitor dynamic process parameters of ongoing events (e.g. water level of a debris flow) and incorporate minor lead times. They have a local geographical coverage and a predefined threshold determines if an alarm is automatically activated to warn endangered objects, authorities and system operators. ii) Expert systems monitor direct changes in the variable disposition (e.g crack opening before a rock avalanche) or trigger events (e.g. heavy rain) at a local scale before the main event starts and thus offer extended lead times. The final alarm decision incorporates human, model and organisational related factors. iii) Model-based expert systems monitor indirect changes in the variable disposition (e.g. snow temperature, height or solar radiation that influence the occurrence probability

  12. Controlling misses and false alarms in a machine learning framework for predicting uniformity of printed pages

    Science.gov (United States)

    Nguyen, Minh Q.; Allebach, Jan P.

    2015-01-01

    In our previous work1 , we presented a block-based technique to analyze printed page uniformity both visually and metrically. The features learned from the models were then employed in a Support Vector Machine (SVM) framework to classify the pages into one of the two categories of acceptable and unacceptable quality. In this paper, we introduce a set of tools for machine learning in the assessment of printed page uniformity. This work is primarily targeted to the printing industry, specifically the ubiquitous laser, electrophotographic printer. We use features that are well-correlated with the rankings of expert observers to develop a novel machine learning framework that allows one to achieve the minimum "false alarm" rate, subject to a chosen "miss" rate. Surprisingly, most of the research that has been conducted on machine learning does not consider this framework. During the process of developing a new product, test engineers will print hundreds of test pages, which can be scanned and then analyzed by an autonomous algorithm. Among these pages, most may be of acceptable quality. The objective is to find the ones that are not. These will provide critically important information to systems designers, regarding issues that need to be addressed in improving the printer design. A "miss" is defined to be a page that is not of acceptable quality to an expert observer that the prediction algorithm declares to be a "pass". Misses are a serious problem, since they represent problems that will not be seen by the systems designers. On the other hand, "false alarms" correspond to pages that an expert observer would declare to be of acceptable quality, but which are flagged by the prediction algorithm as "fails". In a typical printer testing and development scenario, such pages would be examined by an expert, and found to be of acceptable quality after all. "False alarm" pages result in extra pages to be examined by expert observers, which increases labor cost. But "false

  13. A business analytics capability framework

    Directory of Open Access Journals (Sweden)

    Ranko Cosic

    2015-09-01

    Full Text Available Business analytics (BA capabilities can potentially provide value and lead to better organisational performance. This paper develops a holistic, theoretically-grounded and practically relevant business analytics capability framework (BACF that specifies, defines and ranks the capabilities that constitute an organisational BA initiative. The BACF was developed in two phases. First, an a priori conceptual framework was developed based on the Resource-Based View theory of the firm and a thematic content analysis of the BA literature. Second, the conceptual framework was further developed and refined using a three round Delphi study involving 16 BA experts. Changes from the Delphi study resulted in a refined and confirmed framework including detailed capability definitions, together with a ranking of the capabilities based on importance. The BACF will help academic researchers and industry practitioners to better understand the capabilities that constitute an organisational BA initiative and their relative importance. In future work, the capabilities in the BACF will be operationalised to measure their as-is status, thus enabling organisations to identify key areas of strength and weakness and prioritise future capability improvement efforts.

  14. Technological Dynamics and Social Capability

    DEFF Research Database (Denmark)

    Fagerberg, Jan; Feldman, Maryann; Srholec, Martin

    2014-01-01

    for the sample as a whole between 1998 and 2008. The results indicate that social capabilities, such as well-developed public knowledge infrastructure, an egalitarian distribution of income, a participatory democracy and prevalence of public safety condition the growth of technological capabilities. Possible...

  15. Impaired behavioural response to alarm substance in rainbow trout exposed to copper nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Sovová, Tereza [Ecotoxicology Research and Innovation Centre, School of Biomedical and Biological Sciences, Plymouth University, Devon (United Kingdom); Department of Environmental Chemistry, Faculty of Environmental Technology, Institute of Chemical Technology, Prague (Czech Republic); Boyle, David, E-mail: david.boyle@ualberta.ca [Ecotoxicology Research and Innovation Centre, School of Biomedical and Biological Sciences, Plymouth University, Devon (United Kingdom); Sloman, Katherine A. [School of Science, University of the West of Scotland, Paisley (United Kingdom); Vanegas Pérez, Cecilia [Ecotoxicology Research and Innovation Centre, School of Biomedical and Biological Sciences, Plymouth University, Devon (United Kingdom); Laboratory of Animal Ecophysiology and Aquatic Ecotoxicology, National Autonomous University of Mexico, Mexico City (Mexico); Handy, Richard D. [Ecotoxicology Research and Innovation Centre, School of Biomedical and Biological Sciences, Plymouth University, Devon (United Kingdom)

    2014-07-01

    Highlights: • Copper nanoparticles impaired the behavioural response of trout to alarm substance. • This effect appeared to be greater than in trout exposed to copper sulphate. • Toxicity was mediated by interaction of materials at external surfaces of fish. • Copper nanoparticles did not affect the morphology of the olfactory rosette. • Copper nanoparticles caused a change in glutathione status in brains of fish. - Abstract: To date, studies of the toxicity of engineered nanoparticles (NPs) in fish have not fully considered effects on olfactory-mediated behaviours, despite their ecological importance. In this study the effects of copper NPs (Cu NPs) on the anti-predator behavioural responses of juvenile rainbow trout (Oncorhynchus mykiss) to trout alarm substance was investigated. Individual fish were exposed for 12 h to a control (no added Cu), 50 μg l⁻¹ of Cu as Cu NPs, or 50 μg l⁻¹ Cu as CuSO₄, after which fish behaviours were analyzed in 10 min periods before and after the addition of the alarm substance stimulus. The response of control fish to deionised water (negative control, no alarm substance stimulus) was also analyzed. The alarm substance elicited a behavioural response in the control fish characterized by an immediate freeze response and the slower resumption of swimming activity compared to negative controls exposed to the sham deionised water stimuli. In fish exposed to Cu NPs, the behavioural response to alarm substance was eliminated, with no significant difference in behaviours compared to negative controls. In comparison, exposure to 50 μg l⁻¹ Cu as CuSO₄ decreased, but did not eliminate the response of fish to alarm substance, which indicated a significantly greater effect of Cu NPs on olfactory mediated behaviours than of the equivalent concentration of Cu as CuSO₄. Measurement of total Cu concentrations in the tissues of fish demonstrated no significant accumulation of Cu from any treatment in gill, liver or brain

  16. Ultrasonic metal welding with a vibration source using longitudinal and torsional vibration transducers

    Science.gov (United States)

    Asami, Takuya; Tamada, Yosuke; Higuchi, Yusuke; Miura, Hikaru

    2017-07-01

    Conventional ultrasonic metal welding for joining dissimilar metals uses a linear vibration locus, although this method suffers from problems such as low overall weld strength. Our previous studies have shown that ultrasonic welding with a planar vibration locus improves the weld strength. However, the vibration source in our previous studies had problems in longitudinal-torsional vibration controllability and small welding tip. Therefore, the study of the optimal shape of the vibration locus was difficult. Furthermore, improvement of weld strength cannot be expected. We have developed a new ultrasonic vibration source that can control the longitudinal-torsional vibration and can connect to a large welding tip. In this study, we clarified the longitudinal-torsional vibration controllability of the developed ultrasonic vibration source. Moreover, we clarified that using the planar locus of the developed vibration source produced a higher weld strength than our previous studies, and clarified the optimal shape of the vibration locus.

  17. Mechanical Vibrations Modeling and Measurement

    CERN Document Server

    Schmitz, Tony L

    2012-01-01

    Mechanical Vibrations:Modeling and Measurement describes essential concepts in vibration analysis of mechanical systems. It incorporates the required mathematics, experimental techniques, fundamentals of modal analysis, and beam theory into a unified framework that is written to be accessible to undergraduate students,researchers, and practicing engineers. To unify the various concepts, a single experimental platform is used throughout the text to provide experimental data and evaluation. Engineering drawings for the platform are included in an appendix. Additionally, MATLAB programming solutions are integrated into the content throughout the text. This book also: Discusses model development using frequency response function measurements Presents a clear connection between continuous beam models and finite degree of freedom models Includes MATLAB code to support numerical examples that are integrated into the text narrative Uses mathematics to support vibrations theory and emphasizes the practical significanc...

  18. GENDER PARTICULAR FEATURES OF PSYCHIC STATE OF ALARMNESS OF ADOPTED CHILDREN FROM NEI «CHILDREN’S VILLAGE-SOS»

    Directory of Open Access Journals (Sweden)

    С. П. Иванова

    2014-01-01

    Full Text Available Purpose – to discover gender particular features of psy-chic state of alarmness of adopted children from «Childrens’ village-SOS».Methodology – empirical research of gender particular features of psychic state of alarmness of adopted children with the help of testing.Results – girls’ level of psychic state of alarmness has more high level in comparison with boys from «Children’s village-SOS». It reflects their fears of self-manifestation and of problems and interaction with teachers.Practical implications – information for «mothers», tea-chers and governesses, working in Children’s villages-SOS about particular features of psychological state of alarmness of the adopted children; development of correctional programs, helping to adapt under new living conditions.Purchase on Elibrary.ru > Buy now

  19. Reduction of nestlings’ vocalizations in response to parental alarm calls in the Southern House Wren, Troglodytes musculus

    National Research Council Canada - National Science Library

    Serra, Catalina; Fernández, Gustavo J

    2011-01-01

    .... These functions, however, may not be mutually exclusive. In our study, we assessed if alarm calls uttered by breeding Southern House Wrens, Troglodytes musculus, are made to warn nestlings about risk...

  20. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-08-31

    The deep hard rock drilling environment induces severe vibrations into the drillstring, which can cause reduced rates of penetration (ROP) and premature failure of the equipment. The only current means of controlling vibration under varying conditions is to change either the rotary speed or the weight-on-bit (WOB). These changes often reduce drilling efficiency. Conventional shock subs are useful in some situations, but often exacerbate the problems. The objective of this project is development of a unique system to monitor and control drilling vibrations in a ''smart'' drilling system. This system has two primary elements: (1) The first is an active vibration damper (AVD) to minimize harmful axial, lateral and torsional vibrations. The hardness of this damper will be continuously adjusted using a robust, fast-acting and reliable unique technology. (2) The second is a real-time system to monitor drillstring vibration, and related parameters. This monitor adjusts the damper according to local conditions. In some configurations, it may also send diagnostic information to the surface via real-time telemetry. The AVD is implemented in a configuration using magnetorheological (MR) fluid. By applying a current to the magnetic coils in the damper, the viscosity of the fluid can be changed rapidly, thereby altering the damping coefficient in response to the measured motion of the tool. Phase I of this program entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. Phase I of the project was completed by the revised end date of May 31, 2004. The objectives of this phase were met, and all prerequisites for Phase II have been completed.

  1. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-10-13

    The deep hard rock drilling environment induces severe vibrations into the drillstring, which can cause reduced rates of penetration (ROP) and premature failure of the equipment. The only current means of controlling vibration under varying conditions is to change either the rotary speed or the weight-on-bit (WOB). These changes often reduce drilling efficiency. Conventional shock subs are useful in some situations, but often exacerbate the problems. The objective of this project is development of a unique system to monitor and control drilling vibrations in a ''smart'' drilling system. This system has two primary elements: (1) The first is an active vibration damper (AVD) to minimize harmful axial, lateral and torsional vibrations. The hardness of this damper will be continuously adjusted using a robust, fast-acting and reliable unique technology. (2) The second is a real-time system to monitor drillstring vibration, and related parameters. This monitor adjusts the damper according to local conditions. In some configurations, it may also send diagnostic information to the surface via real-time telemetry. The AVD is implemented in a configuration using magnetorheological (MR) fluid. By applying a current to the magnetic coils in the damper, the viscosity of the fluid can be changed rapidly, thereby altering the damping coefficient in response to the measured motion of the tool. Phase I of this program entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. Phase I of the project was completed by the revised end date of May 31, 2004. The objectives of this phase were met, and all prerequisites for Phase II have been completed. The month of June, 2004 was primarily occupied with the writing of the Phase I Final Report, the sole deliverable of Phase I, which will be submitted in the next quarter. Redesign of the laboratory prototype and design of the downhole (Phase II) prototype was

  2. Lattice Metamaterials with Mechanically Tunable Poisson's Ratio for Vibration Control

    Science.gov (United States)

    Chen, Yanyu; Li, Tiantian; Scarpa, Fabrizio; Wang, Lifeng

    2017-02-01

    Metamaterials with artificially designed architectures are increasingly considered as new paradigmatic material systems with unusual physical properties. Here, we report a class of architected lattice metamaterials with mechanically tunable negative Poisson's ratios and vibration-mitigation capability. The proposed lattice metamaterials are built by replacing regular straight beams with sinusoidally shaped ones, which are highly stretchable under uniaxial tension. Our experimental and numerical results indicate that the proposed lattices exhibit extreme Poisson's-ratio variations between -0.7 and 0.5 over large tensile deformations up to 50%. This large variation of Poisson's-ratio values is attributed to the deformation pattern switching from bending to stretching within the sinusoidally shaped beams. The interplay between the multiscale (ligament and cell) architecture and wave propagation also enables remarkable broadband vibration-mitigation capability of the lattice metamaterials, which can be dynamically tuned by an external mechanical stimulus. The material design strategy provides insights into the development of classes of architected metamaterials with potential applications including energy absorption, tunable acoustics, vibration control, responsive devices, soft robotics, and stretchable electronics.

  3. Honey Bee Inhibitory Signaling Is Tuned to Threat Severity and Can Act as a Colony Alarm Signal

    OpenAIRE

    Ken Tan; Shihao Dong; Xinyu Li; Xiwen Liu; Chao Wang; Jianjun Li; Nieh, James C

    2016-01-01

    Alarm communication is a key adaptation that helps social groups resist predation and rally defenses. In Asia, the world's largest hornet, Vespa mandarinia, and the smaller hornet, Vespa velutina, prey upon foragers and nests of the Asian honey bee, Apis cerana. We attacked foragers and colony nest entrances with these predators and provide the first evidence, in social insects, of an alarm signal that encodes graded danger and attack context. We show that, like Apis mellifera, A. cerana poss...

  4. Stroboscopic shearography for vibration analysis

    Science.gov (United States)

    Steinchen, Wolfgang; Kupfer, Gerhard; Maeckel, Peter; Voessing, Frank

    1999-09-01

    Digital Shearography, a laser interferometric technique in conjunction with the digital image processing, has the potential for vibration analysis due to its simple optical system and insensitivity against small rigid body motions. This paper will focus on its recent developments for vibration analysis and for nondestructive testing (NDT) by dynamic (harmonical) excitation. With the introduction of real time observation using automatically refreshing reference frame, both small and large rigid body motions are greatly suppressed. The development of a smaller and more mobile measuring device in conjunction with a user guided comfortable program Shearwin enables the digital shearography to be applied easily as an industrial online testing tool.

  5. Vibrational Collapse of Hexapod Packings

    Science.gov (United States)

    Zhao, Yuchen; Ding, Jingqiu; Barés, Jonathan; Zheng, Hu; Dierichs, Karola; Menges, Achim; Behringer, Robert

    2017-06-01

    Columns made of convex noncohesive grains like sand collapse after being released from a confining container. However, structures built from non-convex grains can be stable without external support. In the current experiments, we investigate the effect of vibration on destroying such columns. The change of column height during vertical vibration, can be well characterized by stretched exponential relaxation when the column is short, which is in agreement with previous work, while a faster collapse happens when the column is tall. We investigate the collapse after the fast process including its dependence on column geometry, and on interparticle and basal friction.

  6. Innovative Techniques Simplify Vibration Analysis

    Science.gov (United States)

    2010-01-01

    In the early years of development, Marshall Space Flight Center engineers encountered challenges related to components in the space shuttle main engine. To assess the problems, they evaluated the effects of vibration and oscillation. To enhance the method of vibration signal analysis, Marshall awarded Small Business Innovation Research (SBIR) contracts to AI Signal Research, Inc. (ASRI), in Huntsville, Alabama. ASRI developed a software package called PC-SIGNAL that NASA now employs on a daily basis, and in 2009, the PKP-Module won Marshall s Software of the Year award. The technology is also used in many industries: aircraft and helicopter, rocket engine manufacturing, transportation, and nuclear power."

  7. Marketing Capability in Strategy Research

    DEFF Research Database (Denmark)

    Ritter, Thomas; Distel, Andreas Philipp

    Following the call for a demand-side perspective of strategic management (e.g., Priem et al., 2012), a firm’s marketing capability, i.e. its ability to interact with down-stream stakeholders, becomes a pivotal element in explaining a firm’s competitiveness. While marketing capability is recognize...... ground for advancing marketing capability research and thus supporting the demand-side perspective in strategic management, we develop an integrative framework to explain the differences and propose a research agenda for developing the field....

  8. A rule-based approach for the correlation of alarms to support Disaster and Emergency Management

    Science.gov (United States)

    Gloria, M.; Minei, G.; Lersi, V.; Pasquariello, D.; Monti, C.; Saitto, A.

    2009-04-01

    Key words: Simple Event Correlator, Agent Platform, Ontology, Semantic Web, Distributed Systems, Emergency Management The importance of recognition of emergency's typology to control the critical situation for security of citizens has been always recognized. It follows this aspect is very important for proper management of a hazardous event. In this work we present a solution for the recognition of emergency's typology adopted by an Italian research project, called CI6 (Centro Integrato per Servizi di Emergenza Innovativi). In our approach, CI6 receives alarms by citizen or people involved in the work (for example: police, operator of 112, and so on). CI6 represents any alarm by a set of information, including a text that describes it and obtained when the user points out the danger, and a pair of coordinates for its location. The system realizes an analysis of text and automatically infers information on the type of emergencies by means a set of parsing rules and rules of inference applied by a independent module: a correlator of events based on their log and called Simple Event Correlator (SEC). SEC, integrated in CI6's platform, is an open source and platform independent event correlation tool. SEC accepts input both files and text derived from standard input, making it flexible because it can be matched to any application that is able to write its output to a file stream. The SEC configuration is stored in text files as rules, each rule specifying an event matching condition, an action list, and optionally a Boolean expression whose truth value decides whether the rule can be applied at a given moment. SEC can produce output events by executing user-specified shell scripts or programs, by writing messages to files, and by various other means. SEC has been successfully applied in various domains like network management, system monitoring, data security, intrusion detection, log file monitoring and analysis, etc; it has been used or integrated with many

  9. Energetics, structures, vibrational frequencies, vibrational absorption, vibrational circular dichroism and Raman intensities of Leu-enkephalin

    DEFF Research Database (Denmark)

    Jalkanen, Karl J.

    2003-01-01

    Here we present several low energy conformers of Leu-enkephalin (LeuE) calculated with the density functional theory using the Becke 3LYP hybrid functional and the 6-31G* basis set. The structures, conformational energies, vibrational frequencies, vibrational absorption (VA) intensities......, vibrational circular dichroism (VCD) intensities and Raman scattering intensities are reported for the conformers of LeuE which are expected to be populated at room temperature. The species of LeuE-present in non-polar solvents is the neutral non-ionic species with the NH2 and CO2H groups, in contrast...... to the zwitterionic neutral species with the NH3+ and CO2- groups which predominates in aqueous solution and in the crystal. All of our attempts to find the zwitterionic species in the isolated state failed, with the result that a hydrogen atom from the positively charged N-terminus ammonium group transferred either...

  10. Experimental Study of the Ultrasonic Vibration-Assisted Abrasive Waterjet Micromachining the Quartz Glass

    Directory of Open Access Journals (Sweden)

    Rongguo Hou

    2018-01-01

    Full Text Available The ultrasonic vibration is used to enhance the capability of the abrasive water micromachining glass. And, the ultrasonic vibration is activated on the abrasive waterjet nozzle. The quality of the flow is improved, and the velocity of the abrasive is increased because of the addition of the ultrasonic energy. The relevant experimental results indicate that the erosion depth and the material volume removal of the glass are obviously increased when ultrasonic vibration is working. As for the influence of process parameters on the material removal of the glass such as vibration amplitude, system pressure, distance of the standoff, and abrasive size, the experimental results indicate that the system pressure and vibration contribute greatly to the glass material removal. Also, the erosion depth and the volume of material removal are increased with the increase in the vibration amplitude and system pressure. There are some uplifts found at the edge of erosion pit. Then, it can be inferred that the plastic method is an important material removal method during the machining process of ultrasonic vibration-assisted abrasive waterjet.

  11. Resonant vibration control of rotating beams

    DEFF Research Database (Denmark)

    Svendsen, Martin Nymann; Krenk, Steen; Høgsberg, Jan Becker

    2011-01-01

    Rotatingstructures,like e.g.wind turbine blades, may be prone to vibrations associated with particular modes of vibration. It is demonstrated, how this type of vibrations can be reduced by using a collocated sensor–actuator system, governed by a resonant controller. The theory is here demonstrated...... modal connectivity, only very limited modal spill-over is generated. The controller acts by resonance and therefore has only a moderate energy consumption, and successfully reduces modal vibrations at the resonance frequency....

  12. Advanced Capabilities for Combat Medics

    National Research Council Canada - National Science Library

    Convertino, Victor A; Cooke, William H; Salinas, Jose; Holcomb, John B

    2004-01-01

    The US Army Institute of Surgical Research (USAISR) has the lead for directing the Research Program Area for Advanced Triage Capabilities for Combat Medics in the Medical Research and Materiel Command (MRMC...

  13. Counterforce Targeting Capabilities and Challenges

    National Research Council Canada - National Science Library

    Schneider, Barry R

    2004-01-01

    .... To fully understand what progress the United States has made in counterforce capability, as well as the continuing shortfalls and the way ahead, one has to search for answers to a few key questions, namely...

  14. Imaging acoustic vibrations in an ear model using spectrally encoded interferometry

    Science.gov (United States)

    Grechin, Sveta; Yelin, Dvir

    2018-01-01

    Imaging vibrational patterns of the tympanic membrane would allow an accurate measurement of its mechanical properties and provide early diagnosis of various hearing disorders. Various optical technologies have been suggested to address this challenge and demonstrated in vitro using point scanning and full-field interferometry. Spectrally encoded imaging has been previously demonstrated capable of imaging tissue acoustic vibrations with high spatial resolution, including two-dimensional phase and amplitude mapping. In this work, we demonstrate a compact optical apparatus for imaging acoustic vibrations that could be incorporated into a commercially available digital otoscope. By transmitting harmonic sound waves through the otoscope insufflation port and analyzing the spectral interferograms using custom-built software, we demonstrate high-resolution vibration imaging of a circular rubber membrane within an ear model.

  15. Vibration-based Energy Harvesting Systems Characterization Using Automated Electronic Equipment

    Directory of Open Access Journals (Sweden)

    Ioannis KOSMADAKIS

    2015-04-01

    Full Text Available A measurement bench has been developed to fully automate the procedure for the characterization of a vibration-based energy scavenging system. The measurement system is capable of monitoring all important characteristics of a vibration harvesting system (input and output voltage, current, and other parameters, frequency and acceleration values, etc.. It is composed of a PC, typical digital measuring instruments (oscilloscope, waveform generator, etc., certain sensors and actuators, along with a microcontroller based automation module. The automation of the procedure and the manipulation of the acquired data are performed by LabVIEW software. Typical measurements of a system consisting of a vibrating source, a vibration transducer and an active rectifier are presented.

  16. Methodology for Analysing Controllability and Observability of Bladed Disc Coupled Vibrations

    DEFF Research Database (Denmark)

    Christensen, Rene Hardam; Santos, Ilmar

    2004-01-01

    and observability of bladed discs. The aim is to determine where to locate actuators and sensors in order to be capable of controlling and monitoring both disc lateral and blade vibrations. The analysis methodology is based on the time-variant modal analysis. A numerical example of the methodogy is provided....... A tuned rotating bladed disc is analysed. The analysis shows that blade actuators and sensors are inevitable in order to control and monitor the vibrations. Moreover, it shows that the controllability and observability depends very strongly on the rotational speed.......Many bladed rotating machines such as helicopters, turbines and compressors are susceptible to blade faults due to vibration problems. Typically, blade vibrations in this kind of machines are suppressed by using passive mechanical components. However, when passive control techniques...

  17. A concept for semi-active vibration control with a serial-stiffness-switch system

    Science.gov (United States)

    Min, Chaoqing; Dahlmann, Martin; Sattel, Thomas

    2017-09-01

    This work deals with a new semi-active vibration control concept with a serial-stiffness-switch system (SSSS), which can be seen as one and a half degree-of-freedom system. The proposed switched system is mainly composed of two serial elements, each of which consists of one spring and one switch in parallel with each other. This mechanical structure benefits from a specified switching law based on the zero crossing of velocity in order to realize vibration reduction. In contrast with conventional ways, the new system is capable of harvesting vibration energy as potential energy stored in springs, and then applies it to vibration reduction. In this paper, the concept is characterized, simulated, evaluated, and proven to be able to improve the system response. The equivalent stiffness and natural frequency of the switched system are mathematically formulated and verified.

  18. Digital Shearography and vibration excitation for NDT of aircraft components

    Science.gov (United States)

    Findeis, Dirk; Gryzagoridis, Jasson

    2014-05-01

    Digital Shearography is a laser based inspection method, capable of determining minute surface displacement gradients in response to an applied stress. The non-contacting technique is based on interferometric principles, and produces whole field results. As a result the method has been adapted for defect detection purposes of high value components in the NDT/E industry. In order to obtain an object's surface displacement gradient when applying Digital Shearography, the object has to be stressed. This paper investigates the use of vibration excitation as a stressing technique for the inspection of selected composite aircraft components. The theory of digital Shearography is presented, the inspections using a piezo based vibration probe is outlined, and the results obtained are displayed. A discussion of the results obtained concludes the paper.

  19. Smart Woven Fabrics With Portable And Wearable Vibrating Electronics

    Directory of Open Access Journals (Sweden)

    Özdemir Hakan

    2015-06-01

    Full Text Available The portable and wearable instrumented fabrics capable of measuring biothermal variable is essential for drivers, especially long-distance drivers. Here we report on portable and wearable devices that are able to read the temperature of human body within the woven fabric. The sensory function of the fabric is achieved by temperature sensors, soldered on conductive threads coated with cotton. The presence of stainless steel wires gives these materials conductive properties, enabling the detection of human body temperature and transmitting the signal form sensors to the motors on the fabric. When body temperature decreases, hardware/software platforms send a signal to the vibration motors in order to stimulate the driver. The ‘smart woven fabric’-sensing architecture can be divided into two parts: a textile platform, where portable and wearable devices acquire thermal signals, and hardware/software platforms, to which a sensor sends the acquired data, which send the signals to the vibration motors.

  20. Surface vibrational and structural properties of polymers by HREELS

    Science.gov (United States)

    Pireaux, J. J.; Gregoire, C.; Vermeersch, M.; Thiry, P. A.; Caudano, R.

    1987-10-01

    The extremely promising applications of electron induced vibrational spectroscopy to study the surfaces of polymers and other organic materials are reviewed. It is demonstrated that this technique, which is known as HREELS: high-resolution electron-energy loss spectroscopy, is selectively surface sensitive: information on both the composition and morphology of the polymer surfaces is obtained. However, a quantitative interpretation of the data is not straightforward, as the exact interaction mechanism(s) between the probing electron and the molecular vibrations are not yet ascertained. One of the many illustrations given is the study of the incipient interface formation between a clean cured polyimide film and deposited aluminum which will demonstrate the specific completeness and capabilities of HREELS.

  1. Broadening Access to Geospatial Capabilities

    OpenAIRE

    Song, Carol

    2014-01-01

    Responding to the need for geospatial tool and data capabilities in HUBzero from various communities, a Purdue team is developing and integrating geospatial capabilities into the HUBzero software. Funded by the National Science Foundation’s Data Infrastructure Building Blocks (DIBBs) initiative, the follow-on program to the DataNet program, the GABBs project is a four-year software development effort aiming at enabling researchers, students and citizens to share geospatial data and tools onli...

  2. Judgmental Forecasting of Operational Capabilities

    OpenAIRE

    Hallin, Carina Antonia; Tveterås, Sigbjørn; Andersen, Torben Juul

    2012-01-01

    This paper explores a new judgmental forecasting indicator, the Employee Sensed Operational Capabilities (ESOC). The purpose of the ESOC is to establish a practical prediction tool that can provide early signals about changes in financial performance by gauging frontline employees’ sensing of changes in the firm’s operational capabilities. We present the first stage of the development of ESOC by applying a formative measurement approach to test the index in relation to financia...

  3. Earth Science Capability Demonstration Project

    Science.gov (United States)

    Cobleigh, Brent

    2006-01-01

    A viewgraph presentation reviewing the Earth Science Capability Demonstration Project is shown. The contents include: 1) ESCD Project; 2) Available Flight Assets; 3) Ikhana Procurement; 4) GCS Layout; 5) Baseline Predator B Architecture; 6) Ikhana Architecture; 7) UAV Capability Assessment; 8) The Big Picture; 9) NASA/NOAA UAV Demo (5/05 to 9/05); 10) NASA/USFS Western States Fire Mission (8/06); and 11) Suborbital Telepresence.

  4. Capabilities for Constrained Military Operations

    Science.gov (United States)

    2016-12-01

    information derived from social media, the Internet of Things (IoT) and advanced data analytical methods must be integrated with conventional...Department does have significant capabilities to support whole-of- government approaches. The good news is that The DoD can prevail with inexpensive...for the U.S. to address such conflicts. The good news is that The DoD can prevail with inexpensive capabilities that have low technology risk and on a

  5. Insights into the problem of alarm fatigue with physiologic monitor devices: a comprehensive observational study of consecutive intensive care unit patients.

    Directory of Open Access Journals (Sweden)

    Barbara J Drew

    Full Text Available PURPOSE: Physiologic monitors are plagued with alarms that create a cacophony of sounds and visual alerts causing "alarm fatigue" which creates an unsafe patient environment because a life-threatening event may be missed in this milieu of sensory overload. Using a state-of-the-art technology acquisition infrastructure, all monitor data including 7 ECG leads, all pressure, SpO(2, and respiration waveforms as well as user settings and alarms were stored on 461 adults treated in intensive care units. Using a well-defined alarm annotation protocol, nurse scientists with 95% inter-rater reliability annotated 12,671 arrhythmia alarms. RESULTS: A total of 2,558,760 unique alarms occurred in the 31-day study period: arrhythmia, 1,154,201; parameter, 612,927; technical, 791,632. There were 381,560 audible alarms for an audible alarm burden of 187/bed/day. 88.8% of the 12,671 annotated arrhythmia alarms were false positives. Conditions causing excessive alarms included inappropriate alarm settings, persistent atrial fibrillation, and non-actionable events such as PVC's and brief spikes in ST segments. Low amplitude QRS complexes in some, but not all available ECG leads caused undercounting and false arrhythmia alarms. Wide QRS complexes due to bundle branch block or ventricular pacemaker rhythm caused false alarms. 93% of the 168 true ventricular tachycardia alarms were not sustained long enough to warrant treatment. DISCUSSION: The excessive number of physiologic monitor alarms is a complex interplay of inappropriate user settings, patient conditions, and algorithm deficiencies. Device solutions should focus on use of all available ECG leads to identify non-artifact leads and leads with adequate QRS amplitude. Devices should provide prompts to aide in more appropriate tailoring of alarm settings to individual patients. Atrial fibrillation alarms should be limited to new onset and termination of the arrhythmia and delays for ST-segment and other parameter

  6. Low-energy isovector quadrupole vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Faessler, A.; Nojarov, R.

    1986-01-23

    The low-lying isovector quadrupole vibrations are described by an extension of the vibrational model allowing independent proton and neutron vibrations coupled by the symmetry energy. The recently detected low-lying isovector states in nearly spherical nuclei with N=84 are described well concerning their energies and E2/M1 mixing ratios. (orig.).

  7. Ground Vibration Measurements at LHC Point 4

    Energy Technology Data Exchange (ETDEWEB)

    Bertsche, Kirk; /SLAC; Gaddi, Andrea; /CERN

    2012-09-17

    Ground vibration was measured at Large Hadron Collider (LHC) Point 4 during the winter shutdown in February 2012. This report contains the results, including power and coherence spectra. We plan to collect and analyze vibration data from representative collider halls to inform specifications for future linear colliders, such as ILC and CLIC. We are especially interested in vibration correlations between final focus lens locations.

  8. Rotor Vibration Reduction via Active Hybrid Bearings

    DEFF Research Database (Denmark)

    Nicoletti, Rodrigo; Santos, Ilmar

    2002-01-01

    The use of fluid power to reduce and control rotor vibration in rotating machines is investigated. An active hybrid bearing is studied, whose main objective is to reduce wear and vibration between rotating and stationary machinery parts. By injecting pressurised oil into the oil film, through...... with experiment, and simulations show the feasibility of controlling shaft vibration through this active device....

  9. 33 CFR 159.103 - Vibration test.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vibration test. 159.103 Section...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.103 Vibration test. The device... subjected to a sinusoidal vibration for a period of 12 hours, 4 hours in each of the x, y, and z planes, at...

  10. 14 CFR 27.907 - Engine vibration.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine vibration. 27.907 Section 27.907... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant General § 27.907 Engine vibration. (a) Each engine must be installed to prevent the harmful vibration of any part of the engine or rotorcraft. (b) The addition of the...

  11. 14 CFR 29.251 - Vibration.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Vibration. 29.251 Section 29.251... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Flight Miscellaneous Flight Requirements § 29.251 Vibration. Each part of the rotorcraft must be free from excessive vibration under each appropriate speed and power...

  12. 14 CFR 29.907 - Engine vibration.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine vibration. 29.907 Section 29.907... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant General § 29.907 Engine vibration. (a) Each engine must be installed to prevent the harmful vibration of any part of the engine or rotorcraft. (b) The...

  13. 14 CFR 27.251 - Vibration.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Vibration. 27.251 Section 27.251... STANDARDS: NORMAL CATEGORY ROTORCRAFT Flight Miscellaneous Flight Requirements § 27.251 Vibration. Each part of the rotorcraft must be free from excessive vibration under each appropriate speed and power...

  14. Vibration measurements on timber frame floors

    NARCIS (Netherlands)

    Kuilen, J.W.G. van de; Oosterhout, G.P.C. van; Donkervoort, R.

    1998-01-01

    In the design of lightweight floors vibrational aspects become more and more important. With the foreseen introduction of Eurocode 5 the vibration of timber floors becomes a part of the design for serviceability. Design rules for the vibrational behaviour are given in Eurocode 5. The first rule is

  15. Vibrations in a moving flexible robot arm

    Science.gov (United States)

    Wang, P. K. C.; Wei, Jin-Duo

    1987-01-01

    The vibration in a flexible robot arm modeled by a moving slender prismatic beam is considered. It is found that the extending and contracting motions have destabilizing and stabilizing effects on the vibratory motions, respectively. The vibration analysis is based on a Galerkin approximation with time-dependent basis functions. Typical numerical results are presented to illustrate the qualitative features of vibrations.

  16. Vibration Theory, Vol. 1A

    DEFF Research Database (Denmark)

    Nielsen, Søren R. K.

    The present collection of solved problems has been published as a supplement to the textbook Svingningsteori. Bind 1. Lineær svingningsteori,Aalborg tekniske Universitetsforlag, 1991, whicj is used in the introductory course on linear vibration theory that is being given on th e8th semester...

  17. Vibration Damping Circuit Card Assembly

    Science.gov (United States)

    Hunt, Ronald Allen (Inventor)

    2016-01-01

    A vibration damping circuit card assembly includes a populated circuit card having a mass M. A closed metal container is coupled to a surface of the populated circuit card at approximately a geometric center of the populated circuit card. Tungsten balls fill approximately 90% of the metal container with a collective mass of the tungsten balls being approximately (0.07) M.

  18. Wideband Piezomagnetoelastic Vibration Energy Harvesting

    DEFF Research Database (Denmark)

    Lei, Anders; Thomsen, Erik Vilain

    2014-01-01

    This work presents a small-scale wideband piezomagnetoelastic vibration energy harvester (VEH) aimed for operation at frequencies of a few hundred Hz. The VEH consists of a tape-casted PZT cantilever with thin sheets of iron foil attached on each side of the free tip. The wideband operation...

  19. Ultrafast vibrations of gold nanorings

    DEFF Research Database (Denmark)

    Kelf, T; Tanaka, Y; Matsuda, O

    2011-01-01

    We investigate the vibrational modes of gold nanorings on a silica substrate with an ultrafast optical technique. By comparison with numerical simulations, we identify several resonances in the gigahertz range associated with axially symmetric deformations of the nanoring and substrate. We...

  20. Effect of shelf aging on vibration transmissibility of anti-vibration gloves.

    Science.gov (United States)

    Shibata, Nobuyuki

    2017-10-05

    Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by environmental conditions such as temperature, humidity, and photo-irradiation, which cause material degradation and aging. This study focused on the influence of shelf aging on the vibration attenuation performance of air-packaged anti-vibration gloves following 2 years of shelf aging. Effects of shelf aging on the vibration attenuation performance of anti-vibration gloves were examined according to the Japan industrial standard JIS T8114 test protocol. The findings indicate that shelf aging induces the reduction of vibration attenuation performance in air-packaged anti-vibration gloves.

  1. A model of objects based on KKS for the processing of alarms at the Angra 2 nuclear power plant; Um modelo de objetos baseado em KKS para o processamento de alarmes da usina nuclear de Angra 2

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Paulo Adriano da

    2000-03-01

    The purpose of this work is to present a new model of the alarm annunciation system of the Angra 2 nuclear power plant, using concepts of object based modeling and having as basic the Angra 2 Systems and Components Identification System - KKS. The present structure of the Computerized Alarm System - CAS of Angra 2 does not permit a fast visualization of the incoming alarms in case that a great number of them go off, because the monitors can only show 7 indications at a time. The herein proposed model permits a fast identification of the generated alarms, making possible for the operator to have a general view of the current nuclear power plant status. Its managing tree structure has an hierarchical dependence among its nodes, from where, the presently activated alarms are shown. Its man-machine interface is easy interaction and understand because it is based on structure well known by the Angra 2 operators which is the Angra 2 Systems and Components Identification System - KKS. The project was implemented in the format of an Angra 2 Alarms Supervision System (SSAA), and, for purpose of simulation, 5 system of the Angra 2 Nuclear Power Plant have been chosen. The data used in the project like measurement KKS, measurement limits, unity, setpoints, alarms text and systems flow diagrams, are actual data of the Angra 2 Nuclear Power Plant. The Visual Basic programming Language has been used, with emphasis to the object oriented programming, which and modification, without modifying the program code. Event hough using the Visual Basic for programming, the model has shown, for its purpose, a satisfactory real time execution. (author)

  2. Lifestyle factors and experience of respiratory alarm symptoms in the general population

    DEFF Research Database (Denmark)

    Sele, Lisa Maria Falk; Balasubramaniam, Kirubakaran; Elnegaard, Sandra

    2015-01-01

    BACKGROUND: The first step in the diagnosis of lung cancer is for individuals in the general population to recognise respiratory alarm symptoms (RAS). Knowledge is sparse about RAS and factors associated with experiencing RAS in the general population. This study aimed to estimate the prevalence...... of RAS in the general population, and to analyse possible associations between lifestyle factors and experiencing RAS. METHODS: A web-based survey comprising 100 000 individuals randomly selected from the Danish Civil Registration System. Items regarding experience of RAS (prolonged coughing, shortness...

  3. Development of Students Learning Capabilities and Professional Capabilities

    DEFF Research Database (Denmark)

    Ringtved, Ulla Lunde; Wahl, Christian; Belle, Gianna

    This paper describes the work-in-progress on a project that aims to develop a tool that via learning analytic methods enable students to enhance, document and assess the development of their learning capabilities and professional capabilities in consequence of their self-initiated study activities...... during their bachelor educations. The tool aims at enhancing the development of students’ capabilities to self-initiate, self-regulate and self-assess their study activities. The tool uses the concept of collective intelligence as source for motivation and inspiration in self-initiating study activities...... as well as self-assessing them. The tool is based on a heutagogical approach to support reflection on learning potential in these activities. This enhances the educational use of students self-initiated learning activities by bringing visibility and evidence to them, and thereby bringing value...

  4. A COMPARATIVE STUDY OF WHOLE-BODY VIBRATION EXPOSURE IN TRAIN AND CAR PASSENGERS: A CASE STUDY IN MALAYSIA

    Directory of Open Access Journals (Sweden)

    M.M. Rahman

    2011-12-01

    Full Text Available Trains and cars are the most important modes of transportation throughout the world. In highly developed countries, trains have become essential for human use as the most well-known form of public transportation, whereas the car plays a significant role in prompt human travel from one place to another. The high magnitude of vibration caused by trains and cars may cause health problems in humans, especially low back pain. The aim of this study was to evaluate and validate the values of daily exposure to vibration A(8 and the vibration dose value (VDV in passengers travelling by train and car and to assess the effects produced by this exposure on the human body. Moreover, this study introduces a newly developed whole-body vibration measurement instrumentation system. One train travelling from the east coast to the south of Malaysia was chosen to conduct the study. Whole-body vibration exposure was measured over 8 hours, which is equal to the duration of normal occupational exposure. One car was chosen randomly and whole-body vibration exposure was measured for 5 min and 10 min. All the data were computed using an IEPE(ICPTM accelerometer sensor connected to a DT9837 device which is capable of effectively measuring and analysing vibration. The vibration results were displayed on a personal computer using a custom graphical user interface (GUI. Matlab software was used to interpret the data. From the results, the whole-body vibration exposure level could be determined. It can be concluded that the whole-body vibration absorbed by the human body is enhanced when the magnitude of the vibration exposure experienced by the passengers increased. This was shown by the increased values of daily exposure to vibration A(8 and VDV calculated in the study.

  5. Performance of nonlinear mechanical, resonant-shunted piezoelectric, and electronic vibration absorbers for multi-degree-of-freedom structures

    Science.gov (United States)

    Agnes, Gregory Stephen

    Linear vibration absorbers are a valuable tool used to suppress vibrations due to harmonic excitation in structural systems. Limited evaluation of the performance of nonlinear vibration absorbers for nonlinear structures exists in the current literature. The state of the art is extended in this work to vibration absorbers in their three major physical implementations: the mechanical vibration absorber, the inductive-resistive shunted piezoelectric vibration absorber, and the electronic vibration absorber (also denoted a positive position feedback controller). A single, consistent, physically similar model capable of examining the response of all three devices is developed. The performance of vibration absorbers attached to single-degree-of-freedom structures is next examined for performance, robustness, and stability. Perturbation techniques and numerical analysis combine to yield insight into the tuning of nonlinear vibration absorbers for both linear and nonlinear structures. The results both clarify and validate the existing literature on mechanical vibration absorbers. Several new results, including an analytical expression for the suppression region's location and bandwidth and requirements for its robust performance, are derived. Nonlinear multiple-degree-of-freedom structures are next evaluated. The theory of Non-linear Normal Modes is extended to include consideration of modal damping, excitation, and small linear coupling, allowing estimation of vibration absorber performance. The dynamics of the N+1-degree-of-freedom system reduce to those of a two-degree-of-freedom system on a four-dimensional nonlinear modal manifold, thereby simplifying the analysis. Quantitative agreement is shown to require a higher order model which is recommended for future investigation. Finally, experimental investigation on both single and multi-degree-of-freedom systems is performed since few experiments on this topic are reported in the literature. The experimental results

  6. Accelerator and electrodynamics capability review

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Kevin W [Los Alamos National Laboratory

    2010-01-01

    Los Alamos National Laboratory (LANL) uses capability reviews to assess the science, technology and engineering (STE) quality and institutional integration and to advise Laboratory Management on the current and future health of the STE. Capability reviews address the STE integration that LANL uses to meet mission requirements. The Capability Review Committees serve a dual role of providing assessment of the Laboratory's technical contributions and integration towards its missions and providing advice to Laboratory Management. The assessments and advice are documented in reports prepared by the Capability Review Committees that are delivered to the Director and to the Principal Associate Director for Science, Technology and Engineering (PADSTE). Laboratory Management will use this report for STE assessment and planning. LANL has defined fifteen STE capabilities. Electrodynamics and Accelerators is one of the seven STE capabilities that LANL Management (Director, PADSTE, technical Associate Directors) has identified for review in Fiscal Year (FY) 2010. Accelerators and electrodynamics at LANL comprise a blend of large-scale facilities and innovative small-scale research with a growing focus on national security applications. This review is organized into five topical areas: (1) Free Electron Lasers; (2) Linear Accelerator Science and Technology; (3) Advanced Electromagnetics; (4) Next Generation Accelerator Concepts; and (5) National Security Accelerator Applications. The focus is on innovative technology with an emphasis on applications relevant to Laboratory mission. The role of Laboratory Directed Research and Development (LDRD) in support of accelerators/electrodynamics will be discussed. The review provides an opportunity for interaction with early career staff. Program sponsors and customers will provide their input on the value of the accelerator and electrodynamics capability to the Laboratory mission.

  7. Design Features and Capabilities of the First Materials Science Research Rack

    Science.gov (United States)

    Pettigrew, P. J.; Lehoczky, S. L.; Cobb, S. D.; Holloway, T.; Kitchens, L.

    2003-01-01

    The First Materials Science Research Rack (MSRR-1) aboard the International Space Station (ISS) will offer many unique capabilities and design features to facilitate a wide range of materials science investigations. The initial configuration of MSRR-1 will accommodate two independent Experiment Modules (EMS) and provide the capability for simultaneous on-orbit processing. The facility will provide the common subsystems and interfaces required for the operation of experiment hardware and accommodate telescience capabilities. MSRR1 will utilize an International Standard Payload Rack (ISPR) equipped with an Active Rack Isolation System (ARIS) for vibration isolation of the facility.

  8. The effects of sound level and vibration magnitude on the relative discomfort of noise and vibration.

    Science.gov (United States)

    Huang, Yu; Griffin, Michael J

    2012-06-01

    The relative discomfort caused by noise and vibration, how this depends on the level of noise and the magnitude of vibration, and whether the noise and vibration are presented simultaneously or sequentially has been investigated in a laboratory study with 20 subjects. Noise and vertical vibration were reproduced with all 49 combinations of 7 levels of noise and 7 magnitudes of vibration to allow the discomfort caused by one of the stimuli to be judged relative to the other stimulus using magnitude estimation. In four sessions, subjects judged noise relative to vibration and vibration relative to noise, with both simultaneous and sequential presentations of the stimuli. The equivalence of noise and vibration was not greatly dependent on whether the stimuli were simultaneous or sequential, but highly dependent on whether noise was judged relative to vibration or vibration was judged relative to noise. When judging noise, higher magnitude vibrations appeared to mask the discomfort caused by low levels of noise. When judging vibration, higher level noises appeared to mask the discomfort caused by low magnitudes of vibration. The judgment of vibration discomfort was more influenced by noise than the judgment of noise discomfort was influenced by vibration.

  9. Analytical design and evaluation of an active control system for helicopter vibration reduction and gust response alleviation

    Science.gov (United States)

    Taylor, R. B.; Zwicke, P. E.; Gold, P.; Miao, W.

    1980-01-01

    An analytical study was conducted to define the basic configuration of an active control system for helicopter vibration and gust response alleviation. The study culminated in a control system design which has two separate systems: narrow band loop for vibration reduction and wider band loop for gust response alleviation. The narrow band vibration loop utilizes the standard swashplate control configuration to input controller for the vibration loop is based on adaptive optimal control theory and is designed to adapt to any flight condition including maneuvers and transients. The prime characteristics of the vibration control system is its real time capability. The gust alleviation control system studied consists of optimal sampled data feedback gains together with an optimal one-step-ahead prediction. The prediction permits the estimation of the gust disturbance which can then be used to minimize the gust effects on the helicopter.

  10. Transient vibration of wind turbine blades

    Science.gov (United States)

    Li, Yuanzhe; Li, Minghai; Jiang, Feng

    2017-09-01

    This article aims to the transient vibration of wind turbine blades. We firstly introduce transient vibration and previous studies in this area. The report then shows the fundamental equations and derivation of Euler Equation. A 3-D beam are created to compare the analytical and numerical result. In addition we operate the existing result and Patran result of a truncation wedge beam, especially the frequencies of free vibration and transient vibration. Transient vibration cannot be vanished but in some case it can be reduced.

  11. Numerical Investigation of Flapwise-Torsional Vibration Model of a Smart Section Blade with Microtab

    National Research Council Canada - National Science Library

    Li, Nailu; Balas, Mark J; Yang, Hua; Jiang, Wei; Magar, Kaman T

    2015-01-01

    ... the microtab control capability on flutter instability case and divergence instability case. The effectiveness of the microtab is investigated with the scenarios of different output controllers and actuation deployments for both instability cases. The numerical results show that the microtab can effectively suppress both vibration modes with the appropriate choice of the output feedback controller.

  12. Energy-efficient on-node signal processing for vibration monitoring

    NARCIS (Netherlands)

    Ramachandran, Vignesh Raja Karuppiah; Sanchez Ramirez, Andrea; van der Zwaag, B.J.; Meratnia, Nirvana; Havinga, Paul J.M.

    In recent years, the use of wireless sensor networks for vibration monitoring is emphasized, because of its capability to continuously monitor at hard-to-reach locations of complex machines. Low power consumption is one of the main requirements for the sensor nodes in continuous and long-term

  13. Performance of the Species-Typical Alarm Response in Young Workers of the Ant Myrmica sabuleti (Hymenoptera: Formicidae) Is Induced by Interactions with Mature Workers

    Science.gov (United States)

    Cammaerts, Marie-Claire

    2014-01-01

    Abstract Young workers of the ant Myrmica sabuleti (Hymenoptera: Formicidae) Meinert 1861 perceived nestmate alarm pheromone but did not display normal alarm behavior (orientation toward the source of emission, increased running speed). They changed their initial behavior when in the presence of older nestmates exhibiting normal alarm behavior. Four days later, the young ants exhibited an imperfect version of normal alarm behavior. This change of behavior did not occur in young ants, which were not exposed to older ants reacting to alarm pheromone. Queen ants perceived the alarm pheromone and, after a few seconds, moved toward its source. Thus, the ants’ ability to sense the alarm pheromone and to identify it as an alarm signal is native, while the adult alarm reaction is acquired over time (= age based polyethism) by young ants. It is possible that the change in behavior observed in young ants could be initiated and/or enhanced (via experience-induced developmental plasticity, learning, and/or other mechanisms) by older ants exhibiting alarm behavior. PMID:25525102

  14. A unifying process capability metric

    Directory of Open Access Journals (Sweden)

    John Jay Flaig

    2009-07-01

    Full Text Available A new economic approach to process capability assessment is presented, which differs from the commonly used engineering metrics. The proposed metric consists of two economic capability measures – the expected profit and the variation in profit of the process. This dual economic metric offers a number of significant advantages over other engineering or economic metrics used in process capability analysis. First, it is easy to understand and communicate. Second, it is based on a measure of total system performance. Third, it unifies the fraction nonconforming approach and the expected loss approach. Fourth, it reflects the underlying interest of management in knowing the expected financial performance of a process and its potential variation.

  15. Planning an Automatic Fire Detection, Alarm, and Extinguishing System for Research Laboratories

    Directory of Open Access Journals (Sweden)

    Rostam Golmohamadi

    2014-04-01

    Full Text Available Background & Objectives: Educational and research laboratories in universities have a high risk of fire, because they have a variety of materials and equipment. The aim of this study was to provide a technical plan for safety improvement in educational and research laboratories of a university based on the design of automatic detection, alarm, and extinguishing systems . Methods : In this study, fire risk assessment was performed based on the standard of Military Risk Assessment method (MIL-STD-882. For all laboratories, detection and fire alarm systems and optimal fixed fire extinguishing systems were designed. Results : Maximum and minimum risks of fire were in chemical water and wastewater (81.2% and physical agents (62.5% laboratories, respectively. For studied laboratories, we designed fire detection systems based on heat and smoke detectors. Also in these places, fire-extinguishing systems based on CO2 were designed . Conclusion : Due to high risk of fire in studied laboratories, the best control method for fire prevention and protection based on special features of these laboratories is using automatic detection, warning and fire extinguishing systems using CO2 .

  16. Symmetry breaking on density in escaping ants: experiment and alarm pheromone model.

    Science.gov (United States)

    Li, Geng; Huan, Di; Roehner, Bertrand; Xu, Yijuan; Zeng, Ling; Di, Zengru; Han, Zhangang

    2014-01-01

    The symmetry breaking observed in nature is fascinating. This symmetry breaking is observed in both human crowds and ant colonies. In such cases, when escaping from a closed space with two symmetrically located exits, one exit is used more often than the other. Group size and density have been reported as having no significant impact on symmetry breaking, and the alignment rule has been used to model symmetry breaking. Density usually plays important roles in collective behavior. However, density is not well-studied in symmetry breaking, which forms the major basis of this paper. The experiment described in this paper on an ant colony displays an increase then decrease of symmetry breaking versus ant density. This result suggests that a Vicsek-like model with an alignment rule may not be the correct model for escaping ants. Based on biological facts that ants use pheromones to communicate, rather than seeing how other individuals move, we propose a simple yet effective alarm pheromone model. The model results agree well with the experimental outcomes. As a measure, this paper redefines symmetry breaking as the collective asymmetry by deducing the random fluctuations. This research indicates that ants deposit and respond to the alarm pheromone, and the accumulation of this biased information sharing leads to symmetry breaking, which suggests true fundamental rules of collective escape behavior in ants.

  17. Smells like aphids: orchid flowers mimic aphid alarm pheromones to attract hoverflies for pollination.

    Science.gov (United States)

    Stökl, Johannes; Brodmann, Jennifer; Dafni, Amots; Ayasse, Manfred; Hansson, Bill S

    2011-04-22

    Most insects are dependent on chemical communication for activities such as mate finding or host location. Several plants, and especially orchids, mimic insect semiochemicals to attract insects for unrewarded pollination. Here, we present a new case of pheromone mimicry found in the terrestrial orchid Epipactis veratrifolia. Flowers are visited and pollinated by several species of aphidophagous hoverflies, the females of which also often lay eggs in the flowers. The oviposition behaviour of these hoverflies is mainly guided by aphid-derived kairomones. We show that the flowers produce α- and β-pinene, β-myrcene and β-phellandrene, and that these compounds attract and induce oviposition behaviour in female hoverflies. This floral odour profile is remarkably similar to the alarm pheromone released by several aphid species, such as Megoura viciae. We therefore suggest that E. veratrifolia mimics aphid alarm pheromones to attract hoverflies for pollination; this is the first time, to our knowledge, that such a case of mimicry has been demonstrated.

  18. Daytime avoidance of chemosensory alarm cues by adult sea lamprey (Petromyzon marinus)

    Science.gov (United States)

    Di Rocco, Richard; Belanger, Cowan; Imre, István; Brown, Grant; Johnson, Nicholas S.

    2014-01-01

    Sea lamprey (Petromyzon marinus) avoid damage-released and predator chemosensory cues at night, but their response to these cues during the day is unknown. Here, we explored (i) whether sea lamprey avoid these cues during the day and (ii) the effect of water temperature on the avoidance of chemosensory alarm cues in two diurnal laboratory experiments. We hypothesized that daytime activity would be temperature-dependent and that only sea lamprey vulnerable to predation (i.e., not hiding) would behaviourally respond to chemosensory alarm cues. Ten groups of ten sea lamprey were exposed to one of a variety of potential chemosensory cues. The experiments were conducted over a range of temperatures to quantify the effect of temperature on avoidance behaviour. Consistent with our hypothesis, a higher proportion of animals were active during daytime as water temperature increased. Moving sea lamprey showed an avoidance response to 2-phenylethylamine (a compound found in mammalian urine) and human saliva once water temperatures had risen to mean (±SD) = 13.7 (±1.4) °C. Resting and hiding sea lamprey did not show an avoidance response to any of the experimental stimuli.

  19. Orchid mimics honey bee alarm pheromone in order to attract hornets for pollination.

    Science.gov (United States)

    Brodmann, Jennifer; Twele, Robert; Francke, Wittko; Yi-bo, Luo; Xi-qiang, Song; Ayasse, Manfred

    2009-08-25

    Approximately one-third of the world's estimated 30,000 orchid species are deceptive and do not reward their pollinators with nectar or pollen. Most of these deceptive orchids imitate the scent of rewarding flowers or potential mates. In this study, we investigated the floral scent involved in pollinator attraction to the rewardless orchid Dendrobium sinense, a species endemic to the Chinese island Hainan that is pollinated by the hornet Vespa bicolor. Via chemical analyses and electrophysiological methods, we demonstrate that the flowers of D. sinense produce (Z)-11-eicosen-1-ol and that the pollinator can smell this compound. This is a major compound in the alarm pheromones of both Asian (Apis cerana) and European (Apis mellifera) honey bees and is also exploited by the European beewolf (Philanthus triangulum) to locate its prey. This is the first time that (Z)-11-eicosen-1-ol has been identified as a floral volatile. In behavioral experiments, we demonstrate that the floral scent of D. sinense and synthetic (Z)-11-eicosen-1-ol are both attractive to hornets. Because hornets frequently capture honey bees to feed to their larvae, we suggest that the flowers of D. sinense mimic the alarm pheromone of honey bees in order to attract prey-hunting hornets for pollination.

  20. Large and Dense Swarms: Simulation of a Shortest Path Alarm Propagation

    Directory of Open Access Journals (Sweden)

    Claudia Snels

    2015-07-01

    Full Text Available This paper deals with the transmission of alarm messages in large and dense underwater swarms of Autonomous Underwater Vehicles (AUVs and describes the verification process of the derived algorithm results by means of two simulation tools realized by the authors. A collision-free communication protocol has been developed, tailored to a case where a single AUV needs to send a message to a specific subset of swarm members regarding a perceived danger. The protocol includes a handshaking procedure that creates a silence region before the transmission of the message obtained through specific acoustic tones out of the normal transmission frequencies or through optical signals. This region will include all members of the swarm involved in the alarm message and their neighbours, preventing collisions between them. The AUV sending messages to a target area computes a delay function on appropriate arcs and runs a Dijkstra-like algorithm obtaining a multicast tree. After an explanation of the whole building of this collision-free multicast tree, a simulation has been carried out assuming different scenarios relevant to swarm density, signal power of the modem and the geometrical configuration of the nodes.