WorldWideScience

Sample records for vibrating valve closes

  1. Genesis of the Mechanical Heart Valves' Ultrasonic Closing Clicks

    Science.gov (United States)

    Hasegawa, Jun; Kobayashi, Kenji

    A new in vitro experimental tool was developed to study the mechanism of the ultrasonic closing clicks' genesis of mechanical heart valves. Since the newly developed tester adopted compressed air flow directly instead of the blood analog fluid to drive the mechanical heart valve, it is not possibe to generate any cavitation. Closing clicks were measured with a small accelerometer at the surface of the valve holder made of silicone rubber. Ultrasonic closing clicks as well as audible closing clicks, similar to those measured clinically, could be observed using this setup. Thus, it was confirmed that the ultrasonic closing clicks can be generated without the existence of cavitation. Simultaneous measurements of the valve motion were made with a high-speed video camera, and the analysis of the video frames and clicks showed that higher frequency signal components of more than 50kHz could be generated only at the instant of the closure, which means the collision of the occluder with the housing. Eighteen miniature accelerometers with an area of one square millimeter were developed and stuck on the housing to monitor the distribution of the housing vibrations in detail, and it was found that the vibrations correspond to the ultrasonic closing clicks propagated from the valve stop: the collision point of the occluder with the housing. This fact indicated that the generation of ultrasonic closing clicks are limited to the small area of the collision. From those results, it was concluded that the major origin of the ultrasonic closing clicks' genesis should be the collision of the occluder with the housing.

  2. 46 CFR 154.546 - Excess flow valve: Closing flow.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Excess flow valve: Closing flow. 154.546 Section 154.546... and Process Piping Systems § 154.546 Excess flow valve: Closing flow. (a) The rated closing flow of vapor or liquid cargo for an excess flow valve must be specially approved by the Commandant (CG-522). (b...

  3. Novel passive normally closed microfluidic valve

    CSIR Research Space (South Africa)

    Land, K

    2009-09-01

    Full Text Available -8 lithography and replication molding processes. It was successfully implemented, and initial results show the relationship between the applied pressure and flow rate. In addition to being used as a toggle valve, this design also allows...

  4. Electromagnetically driven, fast opening and closing gas jet valve

    Directory of Open Access Journals (Sweden)

    Mahadevan Krishnan

    2011-03-01

    Full Text Available The design and performance are presented of an electromagnetically driven gas valve [M. Krishnan, J. Wright, and T. Ma, Proceedings of the 13th Advanced Accelerator Concepts Workshop, Santa Cruz, CA, AIP Conf. Proc. No. 1086 (AIP, New York, 2008] that opens in <100  μs, closes in <500  μs, and can operate at pressures of ∼1000  psia to drive supersonic nozzles. Such a valve has applications to laser-plasma accelerators, where the fast opening and closing would allow sharper edges to the flow and also allow higher rep-rate operation without loading the vacuum chamber. The valve action is effected by a flyer plate accelerated by the electromagnetic impulse of a low inductance, spiral wound, strip-line coil driven by a capacitor. Gas flows out of the valve when the seal between this flyer plate and the valve seat is broken. The electromagnetic force greatly exceeds the restoring forces provided by a spring and the gas pressure against the valve seat. Piezoresistive sensor and laser interferometer measurements of flow show that the valve opens in ∼100  μs for all pressures up to 800 psia. The closing time is 500  μs, set by the spring constant and mass. The prototype valve has been operated with helium at 0.5 Hz and at 500 psia for ∼1 hour at a time with no cooling.

  5. Non-Pyrotechnic Zero-Leak Normally Closed Valve

    Science.gov (United States)

    Gillespie, Rebecca

    2010-01-01

    This valve is designed to create a zero-leak seal in a liquid propulsion system that is a functional replacement for the normally closed pyrovalve. Unlike pyrovalves, Nitinol is actuated by simply heating the material to a certain temperature, called the transition temperature. Like a pyrovalve, before actuation, the upstream and downstream sections are separated from one another and from the external environment by closed welded seals. Also like pyrovalves, after actuation, the propellant or pressurant gas can flow without a significant pressure drop but are still separated from the external environment by a closed welded seal. During manufacture, a Nitinol bar is compressed to 93 percent of its original length and fitted tightly into the valve. During operation, the valve is heated until the Nitinol reaches the transition temperature of 95 C; the Nitinol "remembers" its previous longer shape with a very large recovery force causing it to expand and break the titanium parent metal seal to allow flow. Once open, the valve forever remains open. The first prototype valve was designed for high pressure [5,000 psi (=34.5 MPa)] and low flow, typical requirements for pressurant gas valves in liquid propulsion systems. It is possible to modify the dimensions to make low-pressure models or high-flow models, for use downstream of the propellant tanks. This design is simpler, lower risk, and less expensive than the pyrovalve. Although the valve must be in a thermally controlled state (kept below 80 C) to prevent premature actuation, the pyrovalves and electrically actuated initiators have far more taxing handling requirements.

  6. Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.

    Science.gov (United States)

    Ohta, Y; Kikuta, Y; Shimooka, T; Mitamura, Y; Yuhta, T; Dohi, T

    2000-04-01

    Conventional bileaflet prosthetic mechanical heart valves close passively with backflow. Naturally, the valve has problems associated with closure, such as backflow, water hammer effect, and fracture of the leaflet. On the other hand, in the case of the natural aortic valve, the vortex flow in the sinus of Valsalva pushes the leaflet to close, and the valve starts the closing motion earlier than the prosthetic valve as the forward flow decelerates. This closing mechanism is thought to decrease backflow at valve closure. In this study, we propose a new bileaflet mechanical valve resembling a drawbridge in shape, and the prototype valve was designed so that the leaflet closes with the help of the vortex flow in the sinus. The test valve was made of aluminum alloy, and its closing motion was compared to that of the CarboMedics (CM) valve. Both valves were driven by a computer controlled hydraulic mock circulator and were photographed at 648 frames/s by a high speed charge-coupled device (CCD) camera. Each frame of the valve motion image was analyzed with a personal computer, and the opening angles were measured. The flow rate was set as 5.0 L/min. The system was pulsed with 70 bpm, and the systolic/diastolic ratio was 0.3. Glycerin water was used as the circulation fluid at room temperature, and polystyrene particles were used to visualize the streamline. The model of the sinus of Valsalva was made of transparent silicone rubber. As a result, high speed video analysis showed that the test valve started the closing motion 41 ms earlier than the CM valve, and streamline analysis showed that the test valve had a closing mechanism similar to the natural one with the effect of vortex flow. The structure of the test valve was thought to be effective for soft closure and could solve problems associated with closure.

  7. An experimental method for validating compressor valve vibration theory

    NARCIS (Netherlands)

    Habing, R.A.; Peters, M.C.A.M.

    2006-01-01

    This paper presents an experimental method for validating traditional compressor valve theory for unsteady flow conditions. Traditional valve theory considers the flow force acting on the plate and the flow rate as quasi-steady variables. These variables are related via semi-empirical coefficients

  8. Quick-closing valve is actuated by explosive discharge

    Science.gov (United States)

    Majeski, S. J.

    1966-01-01

    Remotely controlled plug-type valve shuts off a high-pressure, high-temperature gas flow in a few milliseconds. The valve is actuated by a commercially available electrically initiated squib of low explosive power. More rapid closure is attainable with squibs containing heavier explosive changes.

  9. Study on hydraulic exciting vibration due to flexible valve in pump system with method of characteristics in the time domain

    Science.gov (United States)

    Yu, Y. H.; Liu, D.; Yang, X. F.; Si, J.

    2017-08-01

    To analyse the flow characteristics of leakage as well as the mechanism of selfexcited vibration in valves, the method of characteristics was used to assess the effect of flexible valve leakage on the self-excited vibration in water-supply pump system. Piezometric head in upstream of the valve as a function of time was obtained. Two comparative schemes were proposed to simulate the process of self-excited vibration by changing the length, the material of the pipeline and the leakage of valves in the above pump system. It is shown that the length and material of the pipe significantly affect the amplitude and cycle of self-excited vibration as well as the increasing rate of the vibration amplitude. In addition, the leakage of the valve has little influence on the amplitude and cycle of self-excited vibration, but has a significant effect on the increasing rate of vibration amplitude. A pipe explosion accident may occur without the inhibiting of self-excited vibration.

  10. On the open/close performance of prosthetic heart valves at high frequencies

    Science.gov (United States)

    Beltran, A.; Zenit, R.

    2013-11-01

    We report experimental observations of the performance of mechanical and biological prosthetic heart valves. The valves are mounted in a test circular channel conected to a flow system that emulates accelerated human-like conditions. The flow is generated by a high frequencie pulsative pump (in the range of 7 to 18 Hz). The objective of the investigation is to find the treshold conditions for which the open/close performance fails. Preliminary results show that for the mechanical valve the failure starts at 436 pulses/min, while for the biological valve, it starts a failing performance is observed for frequencies higher that 462 pulses/min. Even though these values are far from the heart rate in the human body, we use these measurements to further understand the structure-fluid interaction mechanics of the flow through heart valves.

  11. Effect of Induced Vibration on the Blood Flow Properties in a Mechanical Aortic Valve

    Directory of Open Access Journals (Sweden)

    Kadhim Saleem Khalefa

    2014-07-01

    Full Text Available The effect of induced vibration on velocity distribution for the blood flow in the bileaflet mechanical heart valves conveying blood was investigated in this study. The bileaflet valve was simulated as an orifice. The induced vibration is due to the pulsed blood flow in the artery. Results presented in this study were performed using CFD FLUENT software. This analysis is based on the non-linear numerical solution by using a finite-element method, for the system of governing partial differential equations (continuity, momentum of Navier - Stokes equation of blood flow through the orifice. It has been found that as the flow through the orifice increased, the vibration at the orifice inlet increased. For steady state conditions, at Reynolds number 50 the recorded frequency was 20Hz. When the Reynolds number increased to 100 due to the increase in the blood flow the recorded frequency increased to 30Hz. The increase in frequency may result in damaging the blood red cells and platelets which subsequently results in increasing the blood clogging downstream of the orifice.

  12. 46 CFR 154.540 - Quick-closing shut-off valves: Emergency shut-down system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Quick-closing shut-off valves: Emergency shut-down... shut-down system. The quick-closing shut-off valves under §§ 154.530, 154.532, and 154.538 must have an emergency shut-down system that: (a) Closes all the valves; (b) Is actuated by a single control in at least...

  13. Modal-Based Design Improvement of a Butterfly Valve Disc

    OpenAIRE

    Marius Draghiciu; Zoltan-Iosif Korka; Gilbert-Rainer Gillich

    2017-01-01

    The dynamic behaviour control of a butterfly valve is important because, when one of the valve disc natural frequency is close to the frequency of vortex shedding, which appears when the valve is fully open or partially closed, resonance may appear and vibration with significant amplitudes is generated. This paper presents an example by how the design of a butterfly valve disc can be improved by using a modal analysis performed by means of the finite element method. For this purpose, the rese...

  14. Blade Vibration Measurement System for Characterization of Closely Spaced Modes and Mistuning Project

    Data.gov (United States)

    National Aeronautics and Space Administration — There are several ongoing challenges in non-contacting blade vibration and stress measurement systems that can address closely spaced modes and blade-to-blade...

  15. Analysis of Water Hammer with Different Closing Valve Laws on Transient Flow of Hydrogen-Natural Gas Mixture

    National Research Council Canada - National Science Library

    Subani, Norazlina; Amin, Norsarahaida

    2015-01-01

      Water hammer on transient flow of hydrogen-natural gas mixture in a horizontal pipeline is analysed to determine the relationship between pressure waves and different modes of closing and opening of valves...

  16. Effect of vortex generators on the closing transient flow of bileaflet mechanical heart valves

    Science.gov (United States)

    Murphy, David; Dasi, Lakshmi; Yoganathan, Ajit; Glezer, Ari

    2006-11-01

    The time-periodic closing of bileaflet mechanical heart valves is accompanied by a strong flow transient that is associated with the formation of a counter-rotating vortex pair near the b-datum line of leaflet edges. The strong transitory shear that is generated by these vortices may be damaging to blood elements and may result in platelet activation. In the present work, these flow transients are mitigated using miniature vortex generator arrays that are embedded on the surface of the leaflets. Two vortex generator designs were investigated: one design comprised staggered rectangular fins and the other one staggered hemispheres. The closing transients in the absence and presence of the passive vortex generators are characterized using phase locked PIV measurements. The study utilizes a 25 mm St. Jude Medical valve placed in the aortic position of the Georgia Tech left heart simulator. Measurements of the velocity field in the center plane of the leaflets demonstrate that the dynamics of the transient vortices that precede the formation of the leakage jets can be significantly altered and controlled by relatively simple passive modifications of existing valve designs. Human blood experiments validated the effectiveness of miniature vortex generators in reducing thrombus formation by over 42 percent.

  17. Numerical simulation and experimental research of the flow force and forced vibration in the nozzle-flapper valve

    Science.gov (United States)

    Li, Lei; Yan, Hao; Zhang, Hengxuan; Li, Jing

    2018-01-01

    In the pilot stage of nozzle-flapper servo valve, the flow force on the flapper is the key reason that leads to forced vibration of the armature assembly, which may result in the fatigue of the flexure tube in torque motor. To master the principles and features of the flow force and the source of the forced vibration of the armature assembly, mathematical models of flow force and the forced vibration are deduced in this paper. For validating the model, a three-dimensional model is built and a finite element analysis of the flow force with different inlet pressure and deflections is presented and an innovative and experimental rig for measuring the steady and dynamic frequency of flow force is also designed. The characteristic of the main flow force, minor flow force and total flow force are analyzed contrastively, and the experimental results agree well with the CFD results and mathematical model analysis. To find the source of forced vibration of the armature assembly, a knocking method is proposed to measure the natural frequency of armature assembly. By comparing the spectrum of the pressure and vibration movement through experiments, a conclusion can be drawn that the inlet pressure fluctuation near the natural frequency of armature assembly and the asymmetric structure of pilot stage are the necessary and sufficient conditions to make the armature assembly yield forced vibration. In the end, some suggestions have been made to decrease the intensity of forced vibration of the pilot stage according to the findings.

  18. Numerical study of cavitating flow inside a flush valve

    OpenAIRE

    BAYEUL-LAINE, Annie-Claude; Simonet, Sophie; DUTHEIL, Daniel; Caignaert, Guy

    2011-01-01

    In water supply installations, noise pollution often occurs. As a basic component of a system, a flush valve may frequently be a source of noise and vibration generated by cavitation or high turbulence levels. During valve closing or valve opening, cavitation can be a problem. In order to decrease the noise and to improve the design inside a flush valve, some experimental and numerical analyses were carried out in our laboratories. These analyses led to some improvements in the de...

  19. Modeling and Parameter Identification of the Vibration Characteristics of Armature Assembly in a Torque Motor of Hydraulic Servo Valves under Electromagnetic Excitations

    Directory of Open Access Journals (Sweden)

    Jinghui Peng

    2014-07-01

    Full Text Available The resonance of the armature assembly is the main problem leading to the fatigue of the spring pipe in a torque motor of hydraulic servo valves, which can cause the failure of servo valves. To predict the vibration characteristics of the armature assembly, this paper focuses on the mathematical modeling of the vibration characteristics of armature assembly in a hydraulic servo valve and the identification of parameters in the models. To build models more accurately, the effect of the magnetic spring is taken into account. Vibration modal analysis is performed to obtain the mode shapes and natural frequencies, which are necessary to implement the identification of damping ratios in the mathematical models. Based on the mathematical models for the vibration characteristics, the harmonic responses of the armature assembly are analyzed using the finite element method and measured under electromagnetic excitations. The simulation results agree well with the experimental studies.

  20. Analysis of Water Hammer with Different Closing Valve Laws on Transient Flow of Hydrogen-Natural Gas Mixture

    Directory of Open Access Journals (Sweden)

    Norazlina Subani

    2015-01-01

    Full Text Available Water hammer on transient flow of hydrogen-natural gas mixture in a horizontal pipeline is analysed to determine the relationship between pressure waves and different modes of closing and opening of valves. Four types of laws applicable to closing valve, namely, instantaneous, linear, concave, and convex laws, are considered. These closure laws describe the speed variation of the hydrogen-natural gas mixture as the valve is closing. The numerical solution is obtained using the reduced order modelling technique. The results show that changes in the pressure wave profile and amplitude depend on the type of closing laws, valve closure times, and the number of polygonal segments in the closing function. The pressure wave profile varies from square to triangular and trapezoidal shape depending on the type of closing laws, while the amplitude of pressure waves reduces as the closing time is reduced and the numbers of polygonal segments are increased. The instantaneous and convex closing laws give rise to minimum and maximum pressure, respectively.

  1. Mitral valve implantation using off-pump closed beating intracardiac surgery: a feasibility study.

    Science.gov (United States)

    Guiraudon, Gerard M; Jones, Douglas L; Bainbridge, Daniel; Peters, Terry M

    2007-10-01

    We have developed the Universal Cardiac Introducer (UCI) with the aim of modernizing the off-pump, closed, beating, intracardiac approach. This paper reports our ongoing experience with positioning of a prosthetic MV, under image-guidance, substituting for direct vision. The UCI is comprised of two detachable parts: an attachment-cuff and an airlock-introductory chamber for bulky tools. A prosthetic MV was introduced into the left atrium in 12 pigs via the UCI (LA appendage). Transesophageal and 4D epicardial ultrasound were used for guidance. Limitations of ultrasound imaging prompted the development of a multimodality virtual reality (VR) system introduced in the last three animals. There were no complications associated with cardiac access, while achieving proper valve positioning. TEE contributed to navigating, while 4D epicardial ultrasound was adequate for positioning the prosthesis into the MV orifice. VR provided a 3D context for real-time US imaging with precise navigation and positioning using augmented reality representation of the valve. We demonstrated the feasibility of positioning MV prostheses via the UCI. These results suggest the tremendous potential of virtual reality in making access safe and effective for many intracardiac targets, with the ultimate goal of a safe, versatile, clinical application.

  2. The Otto-Atkinson engine. A study of fluid flow and combustion with early and late inlet valve closing

    Energy Technology Data Exchange (ETDEWEB)

    Haakansson, Henrik

    1999-10-01

    This report contains results of measurements on an Otto engine. The purpose for this work has been to do measurements of the flow in the cylinder but also measurements of the cylinder pressure have been performed. The flow measurements are made with the method Laser Doppler Velocimetry, LDV. The reason why these measurements are made at all are the pump losses that implies a lower efficiency for the Otto engine at part load. In this work two alternative ways that highly reduces the pump losses are examined. These are early inlet valve closing and late inlet valve closing. To further increase the efficiency at part load an increased compression ratio has been used together with the different valve strategies. With these two ways of operation, at a part load of about 4 - 5 IMEP{sub net}, increases of about 20% of the net indicated efficiency has been obtained. Additionally this report contains a chapter about the possible use of a variable valve actuation or timing system, VVA or VVT. Many conditions for the Otto cycle can be improved by the use of a variable valve actuation and in this chapter it is dealt with the most important ones.

  3. Apparently the first closed-form solution of vibrating inhomogeneous beam with a tip mass

    Science.gov (United States)

    Elishakoff, I.; Johnson, V.

    2005-09-01

    Whereas there are numerous papers on the free vibrations of beams of uniform or non-uniform cross-section carrying concentrated masses, the problem does not lend itself to the closed-form solution. Here such a solution is reported, apparently for the first time. The solution originally derived for the inhomogeneous beam without a concentrated mass is generalized to include a tip mass. The semi-inverse method is utilized, to achieve this goal.

  4. Flow induced vibration of subsea gas production systems caused by choke valves

    NARCIS (Netherlands)

    Ligterink, N.E.; Groot, R. de; Gharaibah, E.; Slot, H.J.

    2012-01-01

    In the design of subsea flow systems the integrity and reliability is paramount. As the equipment must be designed to operate at a large variety of conditions, inherent to the many processes, evaluation of the integrity is complex. . Flow induced pulsations and vibrations can cause serious design

  5. Flow induced vibration of subsea gas production system caused by choke valves

    NARCIS (Netherlands)

    Ligterink, N.E.; Groot, R. de; Gharaibah, E.; Slot, H.J.

    2012-01-01

    In the design of subsea flow systems the integrity and reliability is paramount. As the equipment must be designed to operate at a large variety of conditions, inherent to the many processes, evaluation of the integrity is complex. . Flow induced pulsations and vibrations can cause serious design

  6. Closed-Loop Input Shaping Control of Vibration in Flexible Structures via Adaptive Sliding Mode Control

    Directory of Open Access Journals (Sweden)

    Ming-Chang Pai

    2012-01-01

    Full Text Available Input shaping technique is widely used in reducing or eliminating residual vibration of flexible structures. The exact elimination of the residual vibration via input shaping technique depends on the amplitudes and instants of impulse application. However, systems always have parameter uncertainties which can lead to performance degradation. In this paper, a closed-loop input shaping control scheme is developed for uncertain flexible structures. The algorithm is based on input shaping control and adaptive sliding mode control. The proposed scheme does not need a priori knowledge of upper bounds on the norm of the uncertainties, but estimates them by using the adaptation technique. This scheme guarantees closed-loop system stability, and yields good performance and robustness in the presence of parameter uncertainties and external disturbances as well. Furthermore, it is shown that increasing the robustness to parameter uncertainties does not lengthen the duration of the impulse sequence. Simulation results demonstrate the efficacy of the proposed closed-loop input shaping control scheme.

  7. A simple method for designing structural models with closely spaced modes of vibration

    Science.gov (United States)

    Hallauer, W. L., Jr.; Weisshaar, T. A.; Shostak, A. G.

    1978-01-01

    A simple method for designing a mathematical model with closely spaced vibration modes is described. The design process begins with a reference model having specified geometry, continuous inertia and stiffness distributions, and degrees of freedom, all of which remain unchanged. Two natural frequencies of this model are then forced together by means of systematic perturbation of the model's discrete inertia and stiffness parameters. There is only one eigenvalue solution per design cycle, and the gradient vector is calculated directly from the resulting modal quantities. The minimization procedure employed is unconstrained. As applications, a cantilevered plane grid model with five degrees of freedom and a bending-torsion-oscillator with eleven degrees of freedom are treated.

  8. Closed-loop control of vibrational population in CO{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Wells, E; Jochim, Bethany; Gregerson, Neal; Averin, R [Department of Physics, Augustana College, Sioux Falls, SD 57197 (United States); McKenna, J; Sayler, A M; Zohrabi, M; Carnes, K D; Ben-Itzhak, I, E-mail: eric.wells@augie.ed [J R Macdonald Laboratory, Department of Physics, Kansas State University, Manhattan, KS 66506 (United States)

    2010-01-14

    An adaptive closed-loop feedback system is used to determine the optimal pulse shapes for manipulating the branching ratio of CO{sup 2+} following ionization by an intense laser pulse. For this target, selecting between the CO{sup 2+} and C{sup +} + O{sup +} final states requires control of the vibrational population distribution in the transient CO{sup 2+}. The ability to both suppress and enhance CO{sup 2+} relative to C{sup +} + O{sup +} is observed, with shaped pulses surpassing a transform-limited pulse by factors of about 10 for suppression and 2 for enhancement. When optimizing small channels, such as non-dissociative CO{sup 2+}, we demonstrate that a feedback signal obtained via a pulse counting technique is more robust than the more typical current mode signal collection. Furthermore, we demonstrate how the pulse counting technique allows control of a coincidence channel, specifically C{sup +} + O{sup +}, by using logical electronic gates. Using these coincidence signals allows more specific final states to be incorporated into closed-loop control.

  9. Assessment of the impact of VIV (Vortex Induced Vibrations) on closely spaced production jumpers

    Energy Technology Data Exchange (ETDEWEB)

    Saint-Marcoux, Jean-Francois; Legras, Jean-Luc; Bastos, Renato; Rochereau, Max [Acergy, London (United Kingdom)

    2009-12-19

    Brazilian deep water projects require new concepts both for Early Production and Extended Tests Systems for which Floating Production units with smaller hulls are cost-efficient. Further more the Brazilian environment precludes spread mooring. This results in closely spaced riser configurations. Acergy has investigated the issue of interference between closely spaced risers for a few years in practice (bundle Riser Towers, SCR's), experimentally (with Scripps Institution of Oceanography), and with CFD (with Texas A and M University). The result has been in 2008 the inclusion of the Blevins model in commercially available software. Nevertheless the assessment of the impact of VIV of the upstream riser remained elusive. Measurements performed in 2007 confirmed that the wake behind a cylinder under VIV was expanded and the hydrodynamic forces on the downstream riser strongly affected when the upstream cylinder was undergoing Vortex Induced Vibrations (VIV). Measurements conducted in 2008 up to a Reynolds number of 140 000 appear to validate an engineering approach of the impact of VIV that can be readily included in commercially available software for design engineering purpose. The paper describes the experimental measurements, the proposed wake model, comparison of the measurements and model. Application to the design of deep water riser and jumper systems is also included. (author)

  10. Transient Flows in a Pipe System with Pump Shut-Down and the Simultaneous Closing of a Spherical Valve

    Science.gov (United States)

    Zhang, Zh.

    2016-11-01

    Because of the limited value of the wave propagation speed in water the propagation of a pressure surge in transient flows can be tracked in the time series. This enables both the pressure head and the flow velocity in pipe flows to be determined as a function of both the coordinate along the pipe and the time. The propagation of the pressure surge includes both wave transmission and reflection. The latter occurs where the flow section is changed. The wave tracking method has been demonstrated as highly accurate and subsequently was applied to much more complex hydraulic systems, in which the pump is shut off and the spherical valve is simultaneously progressively closed. A combined four-quadrant characteristic of the pump and a spherical valve has been worked out, with which the computational procedure for the transient flow in the complex system could be significantly simplified. It has been demonstrated that not only the pressure surge in the hydraulic system but also the rotational speed of the pump could be satisfactorily computed. The computational algorithm has been demonstrated as quite simple, so that all calculations could be performed simply by means of the Microsoft Excel module.

  11. Extended theory of finite Fermi systems: collective vibrations in closed shell nuclei

    Science.gov (United States)

    Kamerdzhiev, S.; Speth, J.; Tertychny, G.

    We review an extension of Migdal's Theory of Finite Fermi Systems which has been developed and applied to collective vibrations in closed shell nuclei in the past 10 years. This microscopic approach is based on a consistent use of the Green function method. Here one considers in a consistent way more complex 1p1h⊗phonon configurations beyond the RPA correlations. Moreover, these configurations are not only included in the excited states but also explicitly in the ground states of nuclei. The method has been applied to the calculation of the strength distribution and transition densities of giant electric and magnetic resonances in stable and unstable magic nuclei. Using these microscopic transition densities, cross sections for inelastic electron and alpha scattering have been calculated and compared with the available experimental data. The method also allows one to extract in a consistent way the magnitude of the strength of the various multipoles in the energy regions in which several multipoles overlap. We compare the microscopic transition densities, the strength distributions and the various multipole strengths with their values extracted phenomenologically.

  12. Extended theory of finite Fermi systems: collective vibrations in closed shell nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Kamerdzhiev, S.; Speth, J.; Tertychny, G

    2004-03-01

    We review an extension of Migdal's Theory of Finite Fermi Systems which has been developed and applied to collective vibrations in closed shell nuclei in the past 10 years. This microscopic approach is based on a consistent use of the Green function method. Here one considers in a consistent way more complex 1p1h*phonon configurations beyond the RPA correlations. Moreover, these configurations are not only included in the excited states but also explicitly in the ground states of nuclei. The method has been applied to the calculation of the strength distribution and transition densities of giant electric and magnetic resonances in stable and unstable magic nuclei. Using these microscopic transition densities, cross sections for inelastic electron and alpha scattering have been calculated and compared with the available experimental data. The method also allows one to extract in a consistent way the magnitude of the strength of the various multipoles in the energy regions in which several multipoles overlap. We compare the microscopic transition densities, the strength distributions and the various multipole strengths with their values extracted phenomenologically.

  13. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  14. On the effects of leaflet microstructure and constitutive model on the closing behavior of the mitral valve.

    Science.gov (United States)

    Lee, Chung-Hao; Rabbah, Jean-Pierre; Yoganathan, Ajit P; Gorman, Robert C; Gorman, Joseph H; Sacks, Michael S

    2015-11-01

    Recent long-term studies showed an unsatisfactory recurrence rate of severe mitral regurgitation 3-5 years after surgical repair, suggesting that excessive tissue stresses and the resulting strain-induced tissue failure are potential etiological factors controlling the success of surgical repair for treating mitral valve (MV) diseases. We hypothesized that restoring normal MV tissue stresses in MV repair techniques would ultimately lead to improved repair durability through the restoration of MV normal homeostatic state. Therefore, we developed a micro- and macro- anatomically accurate MV finite element model by incorporating actual fiber microstructural architecture and a realistic structure-based constitutive model. We investigated MV closing behaviors, with extensive in vitro data used for validating the proposed model. Comparative and parametric studies were conducted to identify essential model fidelity and information for achieving desirable accuracy. More importantly, for the first time, the interrelationship between the local fiber ensemble behavior and the organ-level MV closing behavior was investigated using a computational simulation. These novel results indicated not only the appropriate parameter ranges, but also the importance of the microstructural tuning (i.e., straightening and re-orientation) of the collagen/elastin fiber networks at the macroscopic tissue level for facilitating the proper coaptation and natural functioning of the MV apparatus under physiological loading at the organ level. The proposed computational model would serve as a logical first step toward our long-term modeling goal-facilitating simulation-guided design of optimal surgical repair strategies for treating diseased MVs with significantly enhanced durability.

  15. Modal-Based Design Improvement of a Butterfly Valve Disc

    Directory of Open Access Journals (Sweden)

    Marius Draghiciu

    2017-11-01

    Full Text Available The dynamic behaviour control of a butterfly valve is important because, when one of the valve disc natural frequency is close to the frequency of vortex shedding, which appears when the valve is fully open or partially closed, resonance may appear and vibration with significant amplitudes is generated. This paper presents an example by how the design of a butterfly valve disc can be improved by using a modal analysis performed by means of the finite element method. For this purpose, the research reveals the way in which the natural frequencies of the disc can be modified by applying stiffening ribs or changing the dimensions, respective the position of these ribs.

  16. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  17. Forced Transverse Vibration of a Closed Double Single-Walled Carbon Nanotube System Containing a Fluid with Effect of Compressive Axial Load

    Directory of Open Access Journals (Sweden)

    Mehrdad Nasirshoaibi

    2015-01-01

    Full Text Available Based on the Rayleigh beam theory, the forced transverse vibrations of a closed double single-walled carbon nanotube (SWCNT system containing a fluid with a Pasternak layer in-between are investigated. It is assumed that the two single-walled carbon nanotubes of the system are continuously joined by a Pasternak layer and both sides of SWCNTs containing a fluid are closed. The dynamic responses of the system caused by arbitrarily distributed continuous loads are obtained. The effect of compressive axial load on the forced vibrations of the double single-walled carbon nanotube system is discussed for one case of particular excitation loading. The properties of the forced transverse vibrations of the system are found to be significantly dependent on the compressive axial load. The steady-state vibration amplitudes of the SWCNT decrease with increasing of length of SWCNT. Vibrations caused by the harmonic exciting forces are discussed, and conditions of resonance and dynamic vibration absorption are formulated. The SWCNT-type dynamic absorber is a new concept of a dynamic vibration absorber (DVA, which can be applied to suppress excessive vibrations of corresponding SWCNT systems.

  18. In vitro compound A formation in a computer-controlled closed-circuit anesthetic apparatus. Comparison with a classical valve circuit.

    Science.gov (United States)

    Versichelen, L F; Rolly, G; Bouche, M P; Van Bocxlaer, J F; Struys, M M; Van Der Herten, C; De Leenheer, A P; Mortier, E P

    2000-10-01

    Few data exist on compound A during sevoflurane anesthesia when using closed-circuit conditions and sodalime with modern computer-controlled liquid injection. A PhysioFlex apparatus (Dräger, Lübeck, Germany) was connected to an artificial test lung (inflow approximately 160 ml/min carbon dioxide, outflow approximately 200 ml/min, simulating oxygen consumption). Ventilation was set to obtain an end-tidal carbon dioxide partial pressure (Petco2) approximately 40 mmHg. Canister inflow (T degrees in) and outflow (T degrees out) temperatures were measured. Fresh sodalime and charcoal were used. After baseline analysis, sevoflurane concentration was set at 2.1% end-tidal for 120 min. At baseline and at regular intervals thereafter, Petco2, end-tidal sevoflurane, T degrees in, and T degrees out were measured. For inspiratory and expiratory compound A determination, samples of 2-ml gas were taken. These data were compared with those of a classical valve-containing closed-circuit machine. Ten runs were performed in each set-up. Inspired compound A concentrations increased from undetectable to peak at 6.0 (SD 1.3) and 14.3 (SD 2.5) ppm (P temperature in the upper outflow part of the absorbent canister was 24.3 degrees C (SD 3.6) and 39.8 degrees C (SD 1.2) (P valve circuit machines, respectively. Differences between the two machines in compound A concentrations and absorbent canister temperature at the inflow and outflow regions were significantly different (P flow (70 l/min), closed-circuit PhysioFlex machine were significantly lower than in conventional, valve-based machines during closed-circuit conditions. Lower absorbent temperatures, resulting from the high flow, appear to account for the lower compound A formation.

  19. Blade Vibration Measurement System for Characterization of Closely Spaced Modes and Mistuning Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase I project successfully demonstrated that the advanced non-contacting stress measurement system (NSMS) was able to address closely spaced modes and...

  20. Ambient vibration characterization and monitoring of a rock slope close to collapse

    Science.gov (United States)

    Burjánek, Jan; Gischig, Valentin; Moore, Jeffrey R.; Fäh, Donat

    2018-01-01

    We analyse the ambient vibration response of Alpe di Roscioro (AdR), an incipient rock slope failure located above the village Preonzo in southern Switzerland. Following a major failure in May 2012 (volume ˜210 000 m3), the remaining unstable rock mass (˜140 000 m3) remains highly fractured and disrupted, and has been the subject of intensive monitoring. We deployed a small-aperture seismic array at the site shortly after the 2012 failure. The measured seismic response exhibited strong directional amplification (factors up to 35 at 3.5 Hz), higher than previously recorded on rock slopes. The dominant direction of ground motion was found to be parallel to the predominant direction of deformation and perpendicular to open fractures, reflecting subsurface structure of the slope. We then equipped the site with two semi-permanent seismic stations to monitor the seismic response with the goal of identifying changes caused by internal damage that may precede subsequent failure. Although failure has not yet occurred, our data reveal important variations in the seismic response. Amplification factors and resonant frequencies exhibit seasonal trends related (both directly and inversely) to temperature changes and are sensitive to freezing periods (resonant frequencies increase with temperature and during freezing). We attribute these effects to thermal expansion driving microcrack closure, in addition to ice formation, which increase fracture and bulk rock stiffness. We find the site response at AdR is linear over the measured range of weak input motions spanning two orders of magnitude. Our results further develop and refine ambient vibration methods used in rock slope hazard assessment.

  1. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method.

    Science.gov (United States)

    Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie

    2017-12-15

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.

  2. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method

    Directory of Open Access Journals (Sweden)

    Zhinong Jiang

    2017-12-01

    Full Text Available Internal combustion engines (ICEs are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.

  3. Euler-Maclaurin Closed Form Finite State Space Model for a String Applied to Broadband Plate Vibrations

    Directory of Open Access Journals (Sweden)

    Michael J. Panza

    2010-01-01

    Full Text Available The Euler-Maclaurin sun formula is applied to the infinite series Green's function solution in the space-time Laplace transform domain for the one dimensional wave equation for a string fixed at each end. The resulting approximate closed form solution is used to derive a single third order input-output ordinary differential equation to model the string dynamics. The average modal density of a plate is shown to be comparable to a string. A finite three state-space model is developed for the string and applied to the vibrations of a plate subjected to broadband random and impulse inputs. The applications include the direct problem of determining the response to a disturbance input and the inverse problem of identifying the disturbance input with a finite state observer based on the finite string model. Numerical simulations using many plate modes are obtained in the time and frequency domains and are used to compare the multimodal plate model to the finite string based model and to demonstrate how the finite string based model can be used to represent the multimodal vibrations of the plate.

  4. Safety valve for offshore borehole

    Energy Technology Data Exchange (ETDEWEB)

    McGill, H.L.; Randermann, E. Jr.; Musik, O.J.

    1977-10-06

    The invention concerns a new and improved submarine safety valve with a valve element which rotate, which can be used, in emergencies, to separate the wound-up piping which extends into the borehole and to close the production line.

  5. High-performance gap-closing vibrational energy harvesting using electret-polarized dielectric oscillators

    Science.gov (United States)

    Feng, Yue; Yu, Zejie; Han, Yanhui

    2018-01-01

    In conventional gap-closing electret-biased electrostatic energy harvesting (EEEH) schemes, electrets with a very low ratio of electret thickness to permittivity are in great demand to allow the attainment of high power output. However, in practice, pursuing such a low ratio introduces unwanted burdens on the electret stability and therefore the reliability of the EEEH devices. In this paper, we propose a dielectric-oscillator-based electrostatic EH (DEEH) scheme as an alternative approach to harvesting electret-biased electrostatic energy. This approach permits the fabrication of an electret-free closed EH circuit. The DEEH architecture directly collects the electrical energy exclusively through the oscillating dielectric body and thus completely circumvents the restrictions imposed by the electret parameters (thickness and permittivity) on power generation. Significantly, without considering the electret thickness and permittivity, both theoretical analysis and experiments have verified the effectiveness of this DEEH strategy, and a high figure of merit (on the order of 10-8 mW cm-2 V-2 Hz-1) was achieved for low-frequency movements.

  6. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  7. Main Oxidizer Valve Design

    Science.gov (United States)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  8. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    resulted from collision or effusion. A static tower has been applied for the main core of this part of the valve which loses balance state under the effect of collision and bounces to the neighboring part, which results in release of the catch and blockage of the gas passing channel.......It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly...

  9. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  10. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ...

  11. Noncontacting valve-position indicator

    Science.gov (United States)

    Crovella, E. A.; Cummins, R. D.; Wada, J. M.

    1979-01-01

    Position of sealed valve or other movable part is indicated without penetrating housing. Flux from magnets connected to stem of hydraulic valve penetrates pressure wall and is sensed by Hall-effect transducer outside wall. When valve closes, moving stem and magnets, voltage from transducer decreases; thus, stem position is indicated without physical contact.

  12. Flow and mixing of gas in cylinder of a stratified charge engine with two intake valves. Effects of late closing valve timing and intake port configurations; Kyuki nibenshiki sojo kyuki engine no cylinder nai gas ryudo to kongo. Osotoji valve timing oyobi port keijo ni yoru eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Charoenphonphanich, C.; Niwa, H.; Ennoji, H.; Iijima, T. [Tokai University, Tokyo (Japan)

    1997-10-01

    A numerical analysis of the flow and mixing of rich mixture and air inducted into the cylinder through each of the two intake ports of a stratified charge engine have been carried out. Numerical calculations were performed by finite volume method for three types of the intake port configurations: inverse V type, parallel type and V type and two types of valve timing; conventional and late closing (Miller cycle). Velocity field, turbulent kinetic energy and distribution of mixture concentration in the cylinder were examined. 3 refs., 10 figs.

  13. Modeling the Mitral Valve

    Science.gov (United States)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  14. Research on vibration signal of engine based on subband energy method

    Science.gov (United States)

    Wu, Chunmei; Cui, Feng; Zhao, Yong; Fu, Baohong; Ma, Junchi; Yang, Guihua

    2017-04-01

    Based on the research of DA462 type engine cylinder and cylinder head vibration signal of the surface, the signal measured in the time domain and frequency domain are analyzed in detail, draw the following conclusions: the analysis of vibration signal of the subband energy method is applied to the engine, the concentration response of each of the motivation band can clearly be seen. Through the analysis we can see that the combustion excitation frequency response from 0k to 1K, the vibration influence on the body piston lateral impact force is mainly concentrated in 2K˜5K frequency range of Hz, valve opening and closing the excitation response frequency is mainly concentrated in the 3K˜4K range of Hz, and thus locating the valve clearance fault. This method is simple, accurate and practical for the post processing and analysis of vibration signals.

  15. Valve Disease

    Science.gov (United States)

    ... See also on this site: Diseases of the Mitral Valve Diseases of the Aortic Valve Diseases of the Tricuspid ... most invasive option for the treatment of valve disease. During surgery, ... defects of the mitral valve. Replacement is used to treat any diseased ...

  16. A close inspection and vibration sensing aerial robot for steel structures with an EPM-based landing device

    Science.gov (United States)

    Takeuchi, Kazuya; Masuda, Arata; Akahori, Shunsuke; Higashi, Yoshiyuki; Miura, Nanako

    2017-04-01

    This paper proposes an aerial robot that can land on and cling to a steel structure using electric permanent magnets to be- have as a vibration sensor probe for use in vibration-based structural health monitoring. In the last decade, structural health monitoring techniques have been studied intensively to tackle with serious social issues that most of the infrastructures in advanced countries are being deteriorated. In the typical concept of the structural health monitoring, vibration sensors like accelerometers are installed in the structure to continuously collect the dynamical response of the operating structure to find a symptom of the structural damage. It is unreasonable, however, to permanently deploy the sensors to numerous infrastructures because most of the infrastructures except for those of primary importance do not need continuous measurement and evaluation. In this study, the aerial robot plays a role of a mobile detachable sensor unit. The design guidelines of the aerial robot that performs the vibration measurement from the analysis model of the robot is shown. Experiments to evaluate the frequency response function of the acceleration measured by the robot with respect to the acceleration at the point where the robot adheres are carried out. And the experimental results show that the prototype robot can measure the acceleration of the host structure accurately up to 150 Hz.

  17. Measurement of reed valve kinematics

    Directory of Open Access Journals (Sweden)

    Fenkl Michael

    2016-01-01

    Full Text Available The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  18. Heart valve surgery

    Science.gov (United States)

    Valve replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... can relieve your symptoms and prolong your life. Mechanical heart valves do not often fail. However, blood clots can ...

  19. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  20. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Rho, Hyung Joon; Lee, Jee Keun [Chonbuk National Univ., Jeonju (Korea, Republic of); Choi, Hee Joo [Firstec Co., Ltd., Changwon (Korea, Republic of)

    2008-01-15

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk.

  1. 46 CFR 56.20-9 - Valve construction.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Valve construction. 56.20-9 Section 56.20-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Valves § 56.20-9 Valve construction. (a) Each valve must close with a right-hand (clockwise...

  2. A comparison between minimized extracorporeal circuits and conventional extracorporeal circuits in patients undergoing aortic valve surgery: is 'minimally invasive extracorporeal circulation' just low prime or closed loop perfusion ?

    OpenAIRE

    Starinieri, Pascal; Declercq, Peter E.; Robic, Boris; Yilmaz, Alaaddin; Van Tornout, Michiel; Dubois, Jasperina; Mees, Urbain; Hendrikx, Marc

    2017-01-01

    Introduction: Even though results have been encouraging, an unequivocal conclusion on the beneficial effect of minimally invasive extracorporeal circulation (MiECC) in patients undergoing aortic valve surgery cannot be derived from previous publications. Long-term outcomes are rarely reported and a significant decrease in operative mortality has not been shown. Most studies have a limited number of patients and are underpowered. They merely report on short-term results of a heterogeneous intr...

  3. Butterfly valve of all rubber lining type

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Shosaku; Nakatsuma, Sumiya (Kubota Ltd., Osaka (Japan)); Sasaki, Iwao; Aoki, Naoshi

    1982-08-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported.

  4. Computational Fluid Dynamics Analysis of Butterfly Valve Performance Factors

    OpenAIRE

    Del Toro, Adam

    2012-01-01

    Butterfly valves are commonly used in industrial applications to control the internal flow of both compressible and incompressible fluids. A butterfly valve typically consists of a metal disc formed around a central shaft, which acts as its axis of rotation. As the valve's opening angle is increased from 0 degrees (fully closed) to 90 degrees (fully open), fluid is able to more readily flow past the valve. Characterizing a valve's performance factors, such as pressure drop, hydrodynamic torqu...

  5. Butterfly valve apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Ball, L.K.; Hines, M.U.; Miller, T.L.

    1990-10-23

    This patent describes a method of controlling fluid flow in a duct, and duct having a wall bounding a flow path wherein flows the fluid. It comprises: disposing a plate-like valve member in the flow path, which valve member is pivotally movable about an axis generally transverse to the duct between a first position transverse to and closing the flow path and a second position generally parallel with the flow path to open and allow fluid flow therein: transecting the valve member with the pivot axis to define with respect to direction of the fluid flow in the duct and pivotal movement of the valve member toward the open position an upstream valve member wing and a downstream valve member wing each substantially equal in area: increasing the effective area of the valve member upon which the fluid flow exerts fluid dynamic flow forces; and pivoting the valve member toward the second open position thereof in response to the increase of effective area.

  6. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... called stenosis). • Don’t close properly and let blood leak where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t close properly (more common in women).As pressure builds inside the left ventricle, it pushes the ...

  7. Variable Valve Actuation

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey Gutterman; A. J. Lasley

    2008-08-31

    the mechanism it was determined that the single cam design did not have enough flexibility to satisfy three critical OEM requirements simultaneously, (maximum valve lift variation, intake valve opening timing and valve closing duration), and a new approach would be necessary. After numerous internal design reviews including several with the OEM a dual cam design was developed that had the flexibility to meet all motion requirements. The second cam added complexity to the mechanism however the cost was offset by the deletion of the electric motor required in the previous design. New patent applications including detailed drawings and potential valve motion profiles were generated and alternate two cam designs were proposed and evaluated for function, cost, reliability and durability. Hardware was designed and built and testing of sample hardware was successfully completed on an engine test stand. The mechanism developed during the course of this investigation can be applied by Original Equipment Manufacturers, (OEM), to their advanced diesel engines with the ultimate goal of reducing emissions and improving fuel economy. The objectives are: (1) Develop an optimal, cost effective, variable valve actuation (VVA) system for advanced low temperature diesel combustion processes. (2) Design and model alternative mechanical approaches and down-select for optimum design. (3) Build and demonstrate a mechanism capable of application on running engines.

  8. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  9. Manufacturable plastic microfluidic valves using thermal actuation.

    Science.gov (United States)

    Pitchaimani, Karthik; Sapp, Brian C; Winter, Adam; Gispanski, Austin; Nishida, Toshikazu; Hugh Fan, Z

    2009-11-07

    A low-cost, manufacturable, thermally actuated, plastic microfluidic valve has been developed. The valve contains an encapsulated, temperature-sensitive fluid, which expands, deflecting a thin elastomeric film into a fluidic channel to control fluid flow. The power input for thermal expansion of each microfluidic valve can be controlled using a printed circuit board (PCB)-based controller, which is suitable for mass production and large-scale integration. A plastic microfluidic device with such valves was fabricated using compression molding and thermal lamination. The operation of the valves was investigated by measuring a change in the microchannel's ionic conduction current mediated by the resistance variation corresponding to the deflection of the microvalve. Valve closing was also confirmed by the disappearance of fluorescence when a fluorescent solution was displaced in the valve region. Valve operation was characterized for heater power ranging from 36 mW to 80 mW. When the valve was actuating, the local channel temperature was 10 to 19 degrees C above the ambient temperature depending on the heater power used. Repetitive valve operations (up to 50 times) have been demonstrated with a flow resulting from a hydrostatic head. Valve operation was tested for a flow rate of 0.33-4.7 microL/min.

  10. Extracellular Matrix Biomarker, Fibulin-1, Is Closely Related to NT-proBNP and Soluble Urokinase Plasminogen Activator Receptor in Patients with Aortic Valve Stenosis (The SEAS Study)

    DEFF Research Database (Denmark)

    Kruger, Ruan; Rasmussen, Lars M; Argraves, William S

    2014-01-01

     = 0.16, p = 0.006, βyear4 = 0.13, p = 0.03) at the expense of the association to aortic valve area index (AVAI) (βyear0 = -0.14, p = 0.005, βyear1 = -0.08, p = 0.11, βyear4 = -0.06, p = 0.22) independently of age, gender, creatinine, and serum aspartate aminotransferase (Adj.Ryear02 = 0.19, Adj.......01), and suPAR (βyear0 = 0.09, p = 0.26, βyear1 = 0.23, βyear4 = 0.21, both pgender, AST and treatment allocation. CONCLUSIONS: Increased levels of fibulin-1 were independently associated with higher levels of suPAR and NT-proBNP especially in patients with lower AVAI, suggesting...

  11. A Study on the Mechanism for Cavitation in the Mechanical Heart Valves with an Electrohydraulic Total Artificial Heart

    Science.gov (United States)

    Lee, Hwansung; Tsukiya, Tomonori; Homma, Akihiko; Kamimura, Tadayuki; Tatsumi, Eisuke; Taenaka, Yoshiyuki; Kitamura, Soichiro

    It has been conceived that the mechanical heart valves mounted in an artificial heart close much faster than in vivo use, resulting in cavitation bubbles formation. In this study, the mechanisms for cavitation in mechanical heart valves (MHVs) is investigated with monoleaflet and bileaflet valves in the mitral position with an electrohydraulic total artificial heart (EHTAH). The valve-closing velocity and pressure-drop through the valve were done, and a high-speed video camera was employed to investigate the mechanism for MHVs cavitation. The valve-closing velocity and pressure-drop of the bileaflet valves were less than that of the monoleaflet valves. Most of the cavitation bubbles in the monoleaflet valves were observed next to the edge of the valve stop and the inner side of the leaflet. With the bileaflet valves, cavitation bubbles were concentrated along the leaflet tip. Also, the number density of cavitation bubbles in the bileaflet valves was less than that of the monoleaflet valves. The number density of cavitation bubbles increased with an increase in the valve-closing velocity and the valve stop area. It is established that squeeze flow holds the key to cavitation in the mechanical heart valve. In a viewpoint of squeeze flow, the bileaflet valve with slow valve-closing velocity and small valve stop area, is safer to prevent of blood cell damage than the monoleaflet valves.

  12. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    to what extent it represents a new blueprint for organization design, despite it being consistent with an “egalitarian Zeitgeist” (Puranam, 2014). In fact, managerial authority may be of increasing importance rather than the opposite (Guadalupe, Li, & Wulf, 2015). Thus, Valve is, and will remain...

  13. Vacuum Valve

    CERN Multimedia

    1974-01-01

    This valve was used in the Intersecting Storage Rings (ISR) to protect against the shock waves that would be caused if air were to enter the vacuum tube. Some of the ISR chambers were very fragile, with very thin walls - a design required by physicists on the lookout for new particles.

  14. Actively Controlled Landing Gear for Aircraft Vibration Reduction

    Science.gov (United States)

    Horta, Lucas G.; Daugherty, Robert H.; Martinson, Veloria J.

    1999-01-01

    Concepts for long-range air travel are characterized by airframe designs with long, slender, relatively flexible fuselages. One aspect often overlooked is ground induced vibration of these aircraft. This paper presents an analytical and experimental study of reducing ground-induced aircraft vibration loads using actively controlled landing gears. A facility has been developed to test various active landing gear control concepts and their performance. The facility uses a NAVY A6-intruder landing gear fitted with an auxiliary hydraulic supply electronically controlled by servo valves. An analytical model of the gear is presented including modifications to actuate the gear externally and test data is used to validate the model. The control design is described and closed-loop test and analysis comparisons are presented.

  15. Intermittent intravalvar regurgitation of a mechanical aortic valve ...

    African Journals Online (AJOL)

    Mechanical prosthetic valve regurgitation may be either periprosthetic or intraprosthetic. The later is usually mild, occurring in the majority of normally functioning valves and is due to the 'regurgitant flow' closing the valve. An unusual case is reported of intermitent intraprosthetic regurgitation through a normally functioning ...

  16. Butterfly valve. Spjeldventil

    Energy Technology Data Exchange (ETDEWEB)

    Cupedo, D.J.

    1984-02-06

    Butterfly valve comprising a body and a valve seat arranged therein, on which a valve member is supported. The valve member comprises an operating rod and the assembly of valve member and operating rod has a fixed pivot point at the bottom of the body. The operating rod can be moved by means of pins movable in grooves and slots in such a manner that when the valve is opened the valve member first pivots about the pivot point to lift the valve member from the seat and subsequently rotates about the pivot point to fully open the valve. 12 drawings.

  17. Conical Seat Shut-Off Valve

    Science.gov (United States)

    Farner, Bruce

    2013-01-01

    A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in

  18. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI...

  19. A New Hemostasis Valve for Neuroendovascular Procedures

    Science.gov (United States)

    Namba, K.; Song, J.K.; Niimi, Y.; Heran, N.S.; Berenstein, A.

    2007-01-01

    Summary A hemostasis valve is routinely used in neuroendovascular procedures to decrease the risk of thromboembolism1,2. Recently, a new hemostasis valve that is designed to minimize blood loss has been introduced. We report our initial experience in using this new hemostasis valve. In neuroendovascular procedures, a hemostasis valve is commonly used for continuous irrigation of guide and microcatheters to decrease the risk of thromboembolism1,2,3. A conventional hemostasis valve has a rotating seal at the end, which is turned open or closed each time a wire or microcatheter/guidewire is introduced or extracted. Often this results in significant back bleeding. When a rotating seal is adjusted suboptimally during a wire or microcatheter manipulation, leakage of pressurized saline from the end of a hemostasis valve results in stagnation of blood within a guiding catheter, which becomes a potential source of emboli during a procedure. The Guardian Haemostasis Valve (Zerusa Limited, Galway, Ireland) is a new hemostasis valve that is designed to minimize blood loss during interventional procedures by minimizing the opening time of the valve during wire or microcatheter insertion. A continuous sealing mechanism during wire or microcatheter positioning minimizes blood loss and stagnation of blood within the guide catheter. We report our initial experience with the Guardian hemostasis valve. PMID:20566129

  20. Engine including hydraulically actuated valvetrain and method of valve overlap control

    Science.gov (United States)

    Cowgill, Joel [White Lake, MI

    2012-05-08

    An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

  1. 49 CFR 178.819 - Vibration test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Vibration test. 178.819 Section 178.819... Testing of IBCs § 178.819 Vibration test. (a) General. The vibration test must be conducted for the... vibration test. (b) Test method. (1) A sample IBC, selected at random, must be filled and closed as for...

  2. Aortic Valve Stenosis

    Science.gov (United States)

    ... rapid, fluttering heartbeat Not eating enough (mainly in children with aortic valve stenosis) Not gaining enough weight (mainly in children with aortic valve stenosis) The heart-weakening effects of aortic valve stenosis ...

  3. Analysis of Valve Requirements for High-Efficiency Digital Displacement Fluid Power Motors

    DEFF Research Database (Denmark)

    Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.

    2013-01-01

    , where both the electro-magnetic actuation, the valve moving mass and the material strength is pushed to the limits. In this present paper a system model describing the digital motor efficiency as a function of valve performance is developed, including a valve opening/closing control method. The valve...

  4. In vitro measurements of aerodynamic characteristics of an improved tracheostoma valve for laryngectomees

    NARCIS (Netherlands)

    Geertsema, AA; de Vries, MP; Schutte, HK; Lubbers, J; Verkerke, GJ

    Tracheostoma valves are often required in the rehabilitation process of speech after total laryngectomy. Patients are thus able to speak without using their hands to close the tracheostoma, The improved Groningen tracheostoma valve consists of a "cough" valve with an integrated ("speech") valve,

  5. What Is Heart Valve Disease?

    Science.gov (United States)

    ... Heart Valves Sometimes heart valves can’t be repaired and must be replaced. This surgery involves removing the faulty valve and replacing it with a man-made or biological valve. Biological valves are made ...

  6. In Vitro Evaluation of the iValve : A Novel Hands-Free Speech Valve

    NARCIS (Netherlands)

    van der Houwen, E.B.; van Kalkeren, T.A.; Burgerhof, J.G.; van der Laan, B.F.; Verkerke, G.J.

    2011-01-01

    Objectives: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure

  7. In vitro evaluation of the iValve: a novel hands-free speech valve.

    Science.gov (United States)

    van der Houwen, Eduard B; van Kalkeren, Tjouwke A; Burgerhof, Johannes G M; van der Laan, Bernard F A M; Verkerke, Gijsbertus J

    2011-12-01

    We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops. This method makes long sentences or pauses difficult. The novel iValve is designed to allow almost natural speech, with mid-sentence pausing and whispering. The inhalation closing flows and exhalation opening pressures of 6 iValve prototype versions at different settings were compared with physiological values. The airflow resistance at inhalation was compared to physiological values and to commercial valve values. The iValve prototypes showed flow and pressure ranges in concordance with the physiological values in the literature. The airflow resistance in the breathing mode was within the physiological airflow resistance range, yet above the values from the two commercial valves. The resistance in the speaking mode was above the physiological airflow resistance range. In vitro tests show that the iValve versions can be selected and adjusted to operate within the physiological range. The airflow resistance in the breathing mode is good. In speaking mode, inhalation should, and can, be decreased. The iValve should offer the patient a more intuitively useable alternative with more dynamic speech. Its low cost allows disposability and wider use.

  8. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  9. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  10. Remote actuated valve implant

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  11. Mitral valve regurgitation

    Science.gov (United States)

    ... around the valve. You are at risk for mitral valve regurgitation if you have: Coronary heart disease and high blood pressure Infection of the heart valves Mitral valve prolapse (MVP) Rare conditions, such as untreated syphilis or Marfan ... heart disease. This is a complication of untreated strep throat ...

  12. Tissue engineered aortic valve

    OpenAIRE

    Dohmen, P M

    2012-01-01

    Several prostheses are available to replace degenerative diseased aortic valves with unique advantages and disadvantages. Bioprotheses show excellent hemodynamic behavior and low risk of thromboembolic complications, but are limited by tissue deterioration. Mechanical heart valves have extended durability, but permanent anticoagulation is mandatory. Tissue engineering created a new generation heart valve, which overcome limitations of biological and mechanical heart valves due to remodelling,...

  13. Cellular regulation of the structure and function of aortic valves

    Directory of Open Access Journals (Sweden)

    Ismail El-Hamamsy

    2010-01-01

    Full Text Available The aortic valve was long considered a passive structure that opens and closes in response to changes in transvalvular pressure. Recent evidence suggests that the aortic valve performs highly sophisticated functions as a result of its unique microscopic structure. These functions allow it to adapt to its hemodynamic and mechanical environment. Understanding the cellular and molecular mechanisms involved in normal valve physiology is essential to elucidate the mechanisms behind valve disease. We here review the structure and developmental biology of aortic valves; we examine the role of its cellular parts in regulating its function and describe potential pathophysiological and clinical implications.

  14. Fluid-solid modeling of lymphatic valves

    Science.gov (United States)

    Caulk, Alexander; Ballard, Matthew; Nepiyushchikh, Zhanna; Dixon, Brandon; Alexeev, Alexander

    2015-11-01

    The lymphatic system performs important physiological functions such as the return of interstitial fluid to the bloodstream to maintain tissue fluid balance, as well as the transport of immune cells in the body. It utilizes contractile lymphatic vessels, which contain valves that open and close to allow flow in only one direction, to directionally pump lymph against a pressure gradient. We develop a fluid-solid model of geometrically representative lymphatic valves. Our model uses a hybrid lattice-Boltzmann lattice spring method to capture fluid-solid interactions with two-way coupling between a viscous fluid and lymphatic valves in a lymphatic vessel. We use this model to investigate the opening and closing of lymphatic valves, and its effect on lymphatic pumping. This helps to broaden our understanding of the fluid dynamics of the lymphatic system.

  15. Mechanical heart valve cavitation in patients with bileaflet valves.

    Science.gov (United States)

    Johansen, Peter; Andersen, Tina S; Hasenkam, J Michael; Nygaard, Hans; Paulsen, Peter K

    2014-01-01

    Today, the quality of mechanical heart valves is quite high, and implantation has become a routine clinical procedure with a low operative mortality (mechanism found to be a possible contributor to these adverse effects is cavitation. In vitro, cavitation has been directly demonstrated by visualization and indirectly in vivo by registering of high frequency pressure fluctuations (HFPF). Tilting disc valves are thought of having higher cavitation potential than bileaflet valves due to higher closing velocities. However, the thromboembolic potential seems to be the same. Further studies are therefore needed to investigate the cavitation potential of bileaflet valves in vivo. The post processing of HFPF have shown difficulties when applied on bileaflet vavles due to asynchronous closure of the two leaflets. The aim of this study was therefore to isolate the pressure signature from each leaflet closure and perform cavitation analyses on each component. Six patients were included in the study (St. Jude Medical (n=3) and CarboMedics (n=3); all aortic bileaflet mechanical heart valves). HFPFs were recorded intraoperatively through a hydrophone at the aortic root. The pressure signature relating to the first and second leaflet closure was isolated and cavitation parameters were calculated (RMS after 50 kHz highpass filtering and signal energy). Data were averaged over 30 heart cycles. For all patients both the RMS value and signal energy of the second leaflet closure were higher than for the first leaflet closure. This indicates that the second leaflet closure is most prone to cause cavitation. Therefore, quantifying cavitation based on the HFPF related to the second leaflet closure may suggest that the cavitation potential for bileaflet valves in vivo may be higher than previous studies have suggested.

  16. Normal aortic valves stay open much longer in systole than porcine substitutes.

    Science.gov (United States)

    Subhani, Maboo; Kumar, Ramarathnam Krishna; Balakrishnan, Komarakshi R

    2013-06-01

    To compare the opening mechanics of porcine valve substitutes with those of a normal human aortic valve. All commercially available porcine valves are pretreated with glutaraldehyde. This study was undertaken to evaluate the consequences of such treatment on valve mechanics. The opening mechanics of the aortic valve, especially the time taken to open fully from a closed position, and the duration for which the valve is maximally open, were compared in a normal aortic valve, a stent-mounted porcine valve, and a stentless porcine valve, using a finite element model. Despite a 4-fold higher gradient, stent-mounted porcine valves were slower in attaining the fully open position, and the time for which the valve was fully open was almost 25% less than a normal valve. In stentless valves, the compliant root made the initial opening mechanics similar to those of a normal valve. Once this effect was over, the effect of porcine leaflet properties took over, and there was a corresponding delay in the valve opening. Fixing the root with a stent and stiffening the leaflets with glutaraldehyde result in delayed valve opening and decrease the duration for which the valve is fully open, thus contributing to inferior hemodynamics.

  17. Risks for Heart Valve Problems

    Science.gov (United States)

    ... Thromboembolism Aortic Aneurysm More Risks for Heart Valve Problems Updated:Jan 18,2017 Who is at risk ... content was last reviewed May 2016. Heart Valve Problems and Disease • Home • About Heart Valves • Heart Valve ...

  18. Living with Heart Valve Disease

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  19. What Causes Heart Valve Disease?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  20. The Leipzig experience with robotic valve surgery.

    Science.gov (United States)

    Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W

    2000-01-01

    The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.

  1. Mitral valve prolapse

    Science.gov (United States)

    ... mitral valve prolapse is called "mitral valve prolapse syndrome," and includes: Chest pain (not caused by coronary artery disease or a heart attack) Dizziness Fatigue Panic attacks Sensation of feeling the heart beat ( palpitations ) ...

  2. Mitral Valve Stenosis

    Science.gov (United States)

    ... valve stenosis include: Rheumatic fever. A complication of strep throat, rheumatic fever can damage the mitral valve. Rheumatic ... children see your doctor for sore throats. Untreated strep throat infections can develop into rheumatic fever. Fortunately, strep ...

  3. Random Vibration and Torque Tests of Fasteners Secured With Locking Cable, Room Temperature Vulcanized (RTV) Rubber, and Closed Cell Foam to Support the Launch of STS-82

    Science.gov (United States)

    Yost, V. H.

    1997-01-01

    During a walkdown of the Space Transportation System (STS) orbiter for the 82nd Space Shuttle flight (STS-82), technicians found several safety cables for bolts with missing or loose ferrules. Typically, two or three bolts are secured with a cable which passes through one of the holes in the head of each bolt and a ferrule is crimped on each end of the cable to prevent it from coming out of the holes. The purpose of the cable is to prevent bolts from rotating should they become untightened. Other bolts are secured with either a locking cable or wire which is covered with RTV and foam. The RTV and foam would have to be removed to inspect for missing or loose ferrules. To determine whether this was necessary, vibration and torque test fixtures and tests were made to determine whether or not bolts with missing or loose ferrules would unloosen. These tests showed they would not, and the RTV and foam was not removed.

  4. Isolated Pulmonary Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hatamizadeh

    2009-06-01

    Full Text Available Infective endocarditis is one of the most severe complications of parenteral drug abuse. The outstanding clinical feature of infective endocarditis in intravenous drug abusers is the high incidence of right-sided valve infection, and the tricuspid valve is involved in 60% to 70% of the cases. We herein report a case of isolated pulmonic valve infective endocarditis with a native pulmonary valve.

  5. A case of SAPIEN XT valve fallen into left ventricle during valve-in-valve transcatheter aortic valve implantation.

    Science.gov (United States)

    Koizumi, Shigeki; Ehara, Natsuhiko; Nishiya, Kenta; Koyama, Tadaaki

    2017-06-24

    Late transcatheter heart valve embolization is a rare but life-threatening complication of transcatheter aortic valve implantation. Surgical intervention is performed for most cases, but some cases were treated by valve-in-valve transcatheter aortic valve implantation. We describe a patient in whom a 29-mm Edwards SAPIEN XT valve migrated into the left ventricular outflow tract 41 days after the initial implantation. We tried to perform valve-in-valve transcatheter aortic valve implantation using a transfemoral approach. As soon as the second transcatheter heart valve touched the first implanted valve, it fell into the left ventricle. Immediate surgical intervention was required. The first valve was removed, and surgical aortic valve replacement was successfully performed. In conclusion, we should choose surgical aortic valve replacement for late transcatheter heart valve embolization. Even if we need to treat by catheter intervention, transapical approach may be better.

  6. Mechanisms of mechanical heart valve cavitation in an electrohydraulic total artificial heart.

    Science.gov (United States)

    Lee, Hwansung; Taenaka, Yoshiyuki; Kitamura, Soichiro

    2005-01-01

    Until now, we have estimated cavitation for mechanical heart valves (MHV) mounted in an electrohydraulic total artificial heart (EHTAH) with tap water as a working fluid. However, tap water at room temperature is not a proper substitute for blood at 37 degrees C. We therefore investigated MHV cavitation using a glycerin solution that was identical in viscosity and vapor pressure to blood at body temperature. In this study, six different kinds of monoleaflet and bileaflet valves were mounted in the mitral position in an EHTAH, and we investigated the mechanisms for MHV cavitation. The valve closing velocity, pressure drop measurements, and a high-speed video camera were used to investigate the mechanism for MHV cavitation and to select the best MHV for our EHTAH. The closing velocity of the bileaflet valves was slower than that of the monoleaflet valves. Cavitation bubbles were concentrated on the edge of the valve stop and along the leaflet tip. It was established that squeeze flow holds the key to MHV cavitation in our study. Cavitation intensity increased with an increase in the valve closing velocity and the valve stop area. With regard to squeeze flow, the Björk-Shiley valve, because it is associated with slow squeeze flow, and the bileaflet valve with low valve closing velocity and small valve stop areas are better able to prevent blood cell damage than the monoleaflet valves.

  7. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  8. Motor operated valves problems tests and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pinier, D.; Haas, J.L.

    1996-12-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a {open_quotes}boiler{close_quotes} effect: determination of the necessary modifications: development and testing of anti-boiler effect systems.

  9. Hybrid textile heart valve prosthesis: preliminary in vitro evaluation.

    Science.gov (United States)

    Vaesken, Antoine; Pidancier, Christian; Chakfe, Nabil; Heim, Frederic

    2016-09-22

    Transcatheter aortic valve implantation (TAVI) is nowadays a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in these devices for over a decade now with over 100,000 implantations. However, material degradations due to crimping for catheter insertion purpose have been reported, and with only 6-year follow-up, no information is available about the long-term durability of biological tissue. Moreover, expensive biological tissue harvesting and chemical treatment procedures tend to promote the development of synthetic valve leaflet materials. Textile polyester (PET) material is characterized by outstanding folding and strength properties combined with proven biocompatibility and could therefore be considered as a candidate to replace biological valve leaflets in TAVI devices. Nevertheless, the material should be preferentially partly elastic in order to limit water hammer effects at valve closing time and prevent exaggerated stress from occurring into the stent and the valve. The purpose of the present work is to study in vitro the mechanical as well as the hydrodynamic behavior of a hybrid elastic textile valve device combining non-deformable PET yarn and elastic polyurethane (PU) yarn. The hybrid valve properties are compared with those of a non-elastic textile valve. Testing results show improved hydrodynamic properties with the elastic construction. However, under fatigue conditions, the interaction between PU and PET yarns tends to limit the valve durability.

  10. Reduction of the suction losses through reed valves in hermetic reciprocating compressors using a magnet coil

    Science.gov (United States)

    Hopfgartner, J.; Posch, S.; Zuber, B.; Almbauer, R.; Krischan, K.; Stangl, S.

    2017-08-01

    Reed valves are widely used in hermetic reciprocating compressors and are responsible for a large part of the thermodynamic losses. Especially, the suction valve, which is opened nearly during the whole suction stroke, has a big potential for improvement. Usually, suction valves are opened only by vacuum created by the moving piston and should be closed before the compression stroke starts to avoid a reversed mass-flow through the valve. Therefore, the valves are prestressed, which results on the other hand in a higher flow resistance. In this work, a suction valve is investigated, which is not closed by the preload of the valve but by an electromagnetic coil located in the suction muffler neck. Shortly before the piston reaches its bottom dead centre, voltage is applied to the coil and a magnetic force is generated which pulls the valve shut. Thereby, the flow resistance through the valve can be reduced by changing the preload on the reed valve because it is no longer needed to close the valve. The investigation of this adapted valve and the electromagnetic coil is firstly done by numerical simulations including fluid structure interactions of the reed valves of a reciprocating compressor and secondly by experiments made on a calorimeter test bench.

  11. Bumblebee vibration activated foraging

    OpenAIRE

    Su, Dan Kuan-Nien

    2009-01-01

    The ability use vibrational signals to activate nestmate foraging is found in the highly social bees, stingless bees and honey bees, and has been hypothesized to exist in the closely related, primitively eusocial bumble bees. We provide the first strong and direct evidence that this is correct. Inside the nest, bumble bee foragers produce brief bursts of vibration (foraging activation pulses) at 594.5 Hz for 63±26 ms (velocityRMS=0.46±0.02mm/s, forceRMS=0.8±0.2 mN. Production of these vibrati...

  12. High Energy Vibration for Gas Piping

    Science.gov (United States)

    Lee, Gary Y. H.; Chan, K. B.; Lee, Aylwin Y. S.; Jia, ShengXiang

    2017-07-01

    In September 2016, a gas compressor in offshore Sarawak has its rotor changed out. Prior to this change-out, pipe vibration study was carried-out by the project team to evaluate any potential high energy pipe vibration problems at the compressor’s existing relief valve downstream pipes due to process condition changes after rotor change out. This paper covers high frequency acoustic excitation (HFAE) vibration also known as acoustic induced vibration (AIV) study and discusses detailed methodologies as a companion to the Energy Institute Guidelines for the avoidance of vibration induced fatigue failure, which is a common industry practice to assess and mitigate for AIV induced fatigue failure. Such detailed theoretical studies can help to minimize or totally avoid physical pipe modification, leading to reduce offshore plant shutdown days to plant shutdowns only being required to accommodate gas compressor upgrades, reducing cost without compromising process safety.

  13. High pressure check valve for application in a miniature cryogenic sorption cooler

    NARCIS (Netherlands)

    Burger, Johannes Faas; van der Wekken, M.C.; Berenschot, Johan W.; Holland, Herman J.; ter Brake, Hermanus J.M.; Rogalla, Horst; Gardeniers, Johannes G.E.; Elwenspoek, Michael Curt

    1999-01-01

    This paper presents a check valve with integrated filter that can stand gas pressures of more than 100 bar in the closed direction and which has a very low pressure drop at low absolute gas pressures in the forward direction. The check valve is designed as a part of a check valve unit for

  14. Worcester 1 Inch Solenoid Actuated Gas Operated VPS System Ball Valve

    Energy Technology Data Exchange (ETDEWEB)

    VAN KATWIJK, C.

    2000-06-06

    1 inch Gas-operated full-port ball valve incorporates a solenoid and limit switches as integral parts of the actuator. The valve is normally open and fails safe to the closed position. The associated valve position switch is class GS.

  15. Electromechanically Actuated Valve for Controlling Flow Rate

    Science.gov (United States)

    Patterson, Paul

    2007-01-01

    A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces

  16. Controlling the cavitation phenomenon of evolution on a butterfly valve

    Science.gov (United States)

    Baran, G.; Catana, I.; Magheti, I.; Safta, C. A.; Savu, M.

    2010-08-01

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  17. Cavitation detection of butterfly valve using support vector machines

    Science.gov (United States)

    Yang, Bo-Suk; Hwang, Won-Woo; Ko, Myung-Han; Lee, Soo-Jong

    2005-10-01

    Butterfly valves are popularly used in service in the industrial and water works pipeline systems with large diameter because of its lightweight, simple structure and the rapidity of its manipulation. Sometimes cavitation can occur, resulting in noise, vibration and rapid deterioration of the valve trim, and do not allow further operation. Thus, monitoring of cavitation is of economic interest and is very important in industry. This paper proposes a condition monitoring scheme using statistical feature evaluation and support vector machine (SVM) to detect the cavitation conditions of butterfly valve which used as a flow control valve at the pumping stations. The stationary features of vibration signals are extracted from statistical moments. The SVMs are trained, and then classify normal and cavitation conditions of control valves. The SVMs with the reorganized feature vectors can distinguish the class of the untrained and untested data. The classification validity of this method is examined by various signals acquired from butterfly valves in the pumping stations. And the classification success rate is compared with that of self-organizing feature map neural network (SOFM).

  18. Controlling the cavitation phenomenon of evolution on a butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Baran, G; Safta, C A [Department of Hydraulic and Hydraulic Machineries, University Politehnica of Bucharest, 313 Splaiul Independentei, Bucharest, 060042 (Romania); Catana, I [Department of Control and Computer Science, University Politehnica of Bucharest (Romania); Magheti, I; Savu, M, E-mail: baran_gheorghe@yahoo.co.u [Department of Mechanical Engineering, University Politehnica of Bucharest (Romania)

    2010-08-15

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  19. Fault detection and diagnosis of diesel engine valve trains

    Science.gov (United States)

    Flett, Justin; Bone, Gary M.

    2016-05-01

    This paper presents the development of a fault detection and diagnosis (FDD) system for use with a diesel internal combustion engine (ICE) valve train. A novel feature is generated for each of the valve closing and combustion impacts. Deformed valve spring faults and abnormal valve clearance faults were seeded on a diesel engine instrumented with one accelerometer. Five classification methods were implemented experimentally and compared. The FDD system using the Naïve-Bayes classification method produced the best overall performance, with a lowest detection accuracy (DA) of 99.95% and a lowest classification accuracy (CA) of 99.95% for the spring faults occurring on individual valves. The lowest DA and CA values for multiple faults occurring simultaneously were 99.95% and 92.45%, respectively. The DA and CA results demonstrate the accuracy of our FDD system for diesel ICE valve train fault scenarios not previously addressed in the literature.

  20. Lined 10'' butterfly valve outlasts competitive valves in brine filter system

    Energy Technology Data Exchange (ETDEWEB)

    Gaines, A.

    1982-03-01

    One of the world's largest chlorine production units located in the Gulf Coast area has an extensive brine piping system with a large number of valves. Some of the valves performed well but many failed to meet the service requirements, especially in the brine filtering system with the salt solution at ambient temperatures and pressures about 100 psi. One of these was a 10'' valve. Various types of gear-operated butterfly valves, with an elastomer lining to withstand the somewhat corrosive solution, had been tried but developed leaks and had to be repaired or replaced after 4 to 6 months. The valves became difficult or impossible to operate in some cases when brine leaking past the stem seal attacked the inner surface of the metal valve body and the liner was dislodged by the movement of the disc. In September 1980, a 10'' butterfly valve specifically designed for bubble-tight shut off and zero stem leakage was installed in the brine filter line on a trial basis. The valve has a 1-piece, epoxy-coated ductile iron body with a molded one-piece liner of Hypalon rubber, and a stainless steel stem and disc with splines instead of pins to provide a trouble-free connection. The stem is positively sealed against leakage by a patented spherical machining process on both the disc and the liner. The valve was furnished with a variable ratio gear actuator that has higher torque output when the disc begins to make contact with the seat to assure a bubble-tight shutoff with minimum input torque. The butterfly valve has provided leaktight performance since it was installed in September 1980 and is still easy to open and close by the geared actuator.

  1. Stuck bioprosthetic aortic valve--a new entity? A case report.

    Science.gov (United States)

    Gerrah, Rabin; Pappof, Mark; Shatz, Vadim; Pollak, Arthur; Gilon, Dan

    2005-01-01

    We describe herein a case of bioprosthetic valve malfunction, which closely imitates a stuck valve. Although the term "stuck" was used originally for the immovable mechanical valve leaflets, the echocardiographic manifestation of this malfunction is similar to those of a mechanical one. The clinical presentation of the stuck bioprosthesis is, however, far more benign than a stuck mechanical valve. Familiarity with this entity is important.

  2. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  3. A Hybrid Tissue-Engineered Heart Valve.

    Science.gov (United States)

    Alavi, S Hamed; Kheradvar, Arash

    2015-06-01

    This study describes the efforts to develop and test the first hybrid tissue-engineered heart valve whose leaflets are composed of an extra-thin superelastic Nitinol mesh tightly enclosed by uniform tissue layers composed of multiple cell types. The trileaflet Nitinol mesh scaffolds underwent three-dimensional cell culture with smooth muscle and fibroblast/myofibroblast cells enclosing the mesh, which were finally covered by an endothelial cell layer. Quantitative and qualitative assays were performed to analyze the microstructure of the tissues. A tissue composition almost similar to that of natural heart valve leaflets was observed. The function of the valves and their Nitinol scaffolds were tested in a heart flow simulator that confirmed the trileaflet valves open and close robustly under physiologic flow conditions with an effective orifice area of 75%. The tissue-metal attachment of the leaflets once exposed to physiologic flow rates was tested and approved. Our preliminary results indicate that the novel hybrid approach with nondegradable scaffold for engineering heart valves is viable and may address the issues associated with current tissue-engineered valves developed with degradable scaffolds. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Experimental study of asymmetric heart valve prototype

    Science.gov (United States)

    Vukicevic, M.; Fortini, S.; Querzoli, G.; Cenedese, A.; Pedrizzetti, G.

    2011-11-01

    The mechanical heart valves (MHVs) are extremely important medical devices, commonly used for diseased heart valves replacement. Despite the long term of use and constant design refinement, the MHVs are very far from ideal and their performance is very diverse from that of the native ones. It has been approved that small variations in geometry of valvular leaflets influence the significant change in the intraventricular vortical flow, known as one of the most important factors for the overall functionality of the heart. We have experimentally examined the home-made heart valve prototypes, exclusively modeled for the mitral valve replacement. The performance and energetic properties of the prototypes have been compared with those in the presence of standard MHVs. The analysis was based on the testing of intraventricular fluid dynamics, usually missing criteria for the quality of the valve performance. It has been shown that the asymmetric prototype, with unequal leaflets and D-shaped orifice produces flow patterns and energetic properties close to those found in the healthy subjects. Thus, the break of symmetry in the standard bi-leaflet MHV prosthesis, at least from the fluid dynamics point of view, is worthwhile to be considered for the design of MHVs for the mitral valve replacement.

  5. Genetic Algorithm-Based Design Optimization of Electromagnetic Valve Actuators in Combustion Engines

    Directory of Open Access Journals (Sweden)

    Seung Hwan Lee

    2015-11-01

    Full Text Available In this research, the design of a new electromagnetic engine valve in the limited space of combustion engine is optimized by multidisciplinary simulation using MATLAB and Maxwell. An electromagnetic engine valve actuator using a permanent magnet is a new actuator concept for overcoming the inherent drawbacks of the conventional solenoid-driven electromagnetic engine valve actuator, such as high power consumption and so on. This study aims to maximize the vibration frequency of the armature to reduce the transition time of the engine valve. The higher performance of the new actuator is demonstrated by dynamic finite element analysis.

  6. Valve position tracking for soft landing of electromechanical camless valvetrain

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, W. [Siemens AG, Erlangen (Germany); Stefanopoulou, A.G. [University of Michigan, Ann Arbor, MI (United States). Dept. of Mechanical Engineering

    2001-07-01

    Variable valve opening and closing allows improvements of internal combustion engines and requires precise control of the camless valvetrain actuator. In this paper the valve position tracking in electromechanical camless valvetrains (EMCV) is considered. One of the main problems in the EMCV actuator is the noise and wear associated with high contact velocities during the closing and opening of the valve. The contact velocity of the actuator and the valve can be reduced, and thus, noise and wear, by designing a tracking controller that consists of a linear feedback and an iterative learning controller (ILC). With the ILC methodology every cycle the feedforward signal of the feedback controller is updated based on the error between the actual valve position and the desired position. The methodology is reviewed and simulation results are presented. (author)

  7. Valve position tracking for soft landing of electromechanical camless valvetrain

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, W. [Siemens AG, Erlangen (Germany); Stefanopoulou, A.G. [Michigan Univ., Ann Arbor, MI (United States). Dept. of Mechanical Engineering

    2001-07-01

    Variable valve opening and closing allows improvements of internal combustion engines and requires precise control of the camless valvetrain actuator. In this paper the valve position tracking in electromechanical camless valvetrains (EMCV) is considered. One of the main problems in the EMCV actuator is the noise and wear associated with high contact velocities during the closing and opening of the valve. The contact velocity of the actuator and the valve can be reduced, and thus, noise and wear, by designing a tracking controller that consists of a linear feedback and an iterative learning controller (ILC). With the ILC methodology every cycle the feedforward signal of the feedback controller is updated based on the error between the actual valve position and the desired position. The methodology is reviewed and simulation results are presented. (orig.)

  8. Hemodynamics and Mechanobiology of Aortic Valve Inflammation and Calcification

    Directory of Open Access Journals (Sweden)

    Kartik Balachandran

    2011-01-01

    Full Text Available Cardiac valves function in a mechanically complex environment, opening and closing close to a billion times during the average human lifetime, experiencing transvalvular pressures and pulsatile and oscillatory shear stresses, as well as bending and axial stress. Although valves were originally thought to be passive pieces of tissue, recent evidence points to an intimate interplay between the hemodynamic environment and biological response of the valve. Several decades of study have been devoted to understanding these varied mechanical stimuli and how they might induce valve pathology. Here, we review efforts taken in understanding the valvular response to its mechanical milieu and key insights gained from in vitro and ex vivo whole-tissue studies in the mechanobiology of aortic valve remodeling, inflammation, and calcification.

  9. Monitoring vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Tiryaki, B. [Hacettepe University (Turkey). Dept. of Mining Engineering

    2003-12-01

    The paper examines the prediction and optimisation of machine vibrations in longwall shearers. Underground studies were carried out at the Middle Anatolian Lignite Mine, between 1993 and 1997. Several shearer drums with different pick lacing arrangements were designed and tested on double-ended ranging longwall shearers employed at the mine. A computer program called the Vibration Analysis Program (VAP) was developed for analysing machine vibrations in longwall shearers. Shearer drums that were tested underground, as well as some provided by leading manufacturers, were analyzed using these programs. The results of the experiments and computer analyses are given in the article. 4 refs., 9 figs.

  10. Design And Analysis Of A Camless Valve Mechanism For I.C Engines Using Rotary Disc Valves

    Directory of Open Access Journals (Sweden)

    Vivek Jitendra Panchal

    2017-09-01

    Full Text Available It is the object of the presented paper to provide an electromechanical rotary valve actuating system for opening and closing valves of an internal combustion engine capable of separately controlling both the inlet and exhaust valve operations of each individual cylinder in a multi-cylinder engine. This indicates that only one valve will be required for each cylinder of the engine. Previously published versions of this concept require a separate valve for intake and exhaust in each cylinder. The system provides an alternative to the camshaft assembly in an attempt to overcome the limitations and inadequacies inevitably posed by a fully mechanical system. The prototype development is approached in a theoretical manner beginning with the conceptualization and design of a rotating disk with a notches and corresponding closure surfaces to open and close the flow path. The actuated disk and notch design is then refined and followed by the design of an inlet and exhaust manifold to correspond to the valve design and the theorizing and design of a sealing gasket. The rotating speed of the valve is determined by a general idling speed and can be varied to provide variable valve timing with the motor. The final assembly eliminates a majority of the moving parts currently used in camshaft systems like the cam camshaft rocker arm push rod and springs and results in a significantly lighter valve actuation system. By eliminating the translatory motion of valves the problem of valves slamming on the valve seats at high velocities is eliminated thus greatly reducing engine wear.

  11. Using Abductive Machine Learning for Online Vibration Monitoring of Turbo Molecular Pumps

    Directory of Open Access Journals (Sweden)

    R.E. Abdel-Aal

    1999-01-01

    Full Text Available Turbo molecular vacuum pumps constitute a critical component in many accelerator installations, where failures can be costly in terms of both money and lost beam time. Catastrophic failures can be averted if prior warning is given through a continuous online monitoring scheme. This paper describes the use of modern machine learning techniques for online monitoring of the pump condition through the measurement and analysis of pump vibrations. Abductive machine learning is used for modeling the pump status as ‘good’ or ‘bad’ using both radial and axial vibration signals measured close to the pump bearing. Compared to other statistical methods and neural network techniques, this approach offers faster and highly automated model synthesis, requiring little or no user intervention. Normalized 50-channel spectra derived from the low frequency region (0–10 kHz of the pump vibration spectra provided data inputs for model development. Models derived by training on only 10 observations predict the correct value of the logical pump status output with 100% accuracy for an evaluation population as large as 500 cases. Radial vibration signals lead to simpler models and smaller errors in the computed value of the status output. Performance is comparable with literature data on a similar diagnosis scheme for compressor valves using neural networks.

  12. Experimental Research on Vibration Fatigue of CFRP and Its Influence Factors Based on Vibration Testing

    OpenAIRE

    Fan, Zhengwei; Jiang, Yu; Zhang, Shufeng; Chen, Xun

    2017-01-01

    A new research method based on vibration testing for the vibration fatigue of FRP was proposed in this paper. Through the testing on a closed-loop controlled vibration fatigue test system, the vibration fatigue phenomenon of typical carbon-fiber-reinforced plastic (CFRP) cantilevered laminate specimens was carefully studied. Moreover, a method based on the frequency response function was proposed to monitor the fatigue damage accumulation of specimens. On the basis of that, the influence fact...

  13. Replaceable valve seat

    Science.gov (United States)

    Jordan, Raymond W.

    1992-01-01

    A valve with an O-ring, a disk seal, and a replaceable valve seat is presented. A groove in the bottom on the valve seat flange forms an inner and outer drip ledge with the inner and outer periphery of the flange. If leakage occurs at the valve seat O-ring, fluid droplets will form on the out drip ledge. If leakage occurs at the disk seal, fluid droplets will form on the inner drip ledge. A visual inspection of these drip ledges through an access port, or by a borescope placed in an inspection port, can discriminate between a leak which originates in the O-ring and a leak which originates in the disk seal. When conventional replaceable valve seats leak, fluid droplets form at the bottom on the valve seat. In the present invention, such a valve seat is modified by machining a groove on the bottom surface of the valve seat flange. This groove and the inner and outer surfaces of the flange intersect and form drip ledges. If leakage occurs at the valve seat seal, shown as an O-ring in the preferred embodiment, fluid droplets will form on the outer drip ledge. If leakage occurs at the valve disk seal, fluid droplets will form on the inner drip ledge. The drip ledges can be inspected either through an access port or by passing a borescope through a small inspection port in the valve case. Visual inspection of the bottom on the drip ledge will positively identify the required repair action.

  14. Vibrational Diver

    Science.gov (United States)

    Kozlov, Victor; Ivanova, Alevtina; Schipitsyn, Vitalii; Stambouli, Moncef

    2014-10-01

    The paper is concerned with dynamics of light solid in cavity with liquid subjected to rotational vibration in the external force field. New vibrational phenomenon - diving of a light cylinder to the cavity bottom is found. The experimental investigation of a horizontal annulus with a partition has shown that under vibration a light body situated in the upper part of the layer is displaced in a threshold manner some distance away from the boundary. In this case the body executes symmetric tangential oscillations. An increase of the vibration intensity leads to a tangential displacement of the body near the external boundary. This displacement is caused by the tangential component of the vibrational lift force, which appears as soon as the oscillations lose symmetry. In this case the trajectory of the body oscillatory motion has the form of a loop. The tangential lift force makes stable the position of the body on the inclined section of the layer and even in its lower part. A theoretical interpretation has been proposed, which explains stabilization of a quasi-equilibrium state of a light body near the cavity bottom in the framework of vibrational hydromechanics.

  15. Valve reconstruction for congenital mitral valve disease.

    Science.gov (United States)

    Quinonez, Luis G; Del Nido, Pedro J

    2015-01-01

    The surgical treatment of mitral valve disease in children is a challenging problem. Mitral stenosis and regurgitation may occur in isolation or together. Mitral valve repair is almost always preferable to replacement. Mitral valve replacement is not an ideal alternative to repair due to limitations of size, growth, structural valve degeneration, anticoagulation and poor survival. Surgical repair of congenital mitral stenosis must address the multiple levels of obstruction, including resection of the supramitral ring, thinning of leaflets and mobilization of the subvalvular apparatus. Sometimes leaflet augmentation is required. Repair of mitral regurgitation in children may involve simple cleft closures, edge-to-edge repairs, triangular resections and annuloplasties. Techniques used in adults, such as annuloplasty bands or artificial chords, may not be appropriate for children. Overall, an imperfect mitral valve repair may be more acceptable than the negative consequences of a replacement in a child. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Improvement of a Pneumatic Control Valve with Self-Holding Function

    Science.gov (United States)

    Dohta, Shujiro; Akagi, Tetsuya; Kobayashi, Wataru; Shimooka, So; Masago, Yusuke

    2017-10-01

    The purpose of this study is to develop a small-sized, lightweight and low-cost control valve with low energy consumption and to apply it to the assistive system. We have developed some control valves; a tiny on/off valve using a vibration motor, and an on/off valve with self-holding function. We have also proposed and tested the digital servo valve with self-holding function using permanent magnets and a small-sized servo motor. In this paper, in order to improve the valve, an analytical model of the digital servo valve is proposed. And the simulated results by using the analytical model and identified parameters were compared with the experimental results. Then, the improved digital servo valve was designed based on the calculated results and tested. As a result, we realized the digital servo valve that can control the flow rate more precisely while maintaining its volume and weight compared with the previous valve. As an application of the improved valve, a position control system of rubber artificial muscle was built and the position control was performed successfully.

  17. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ...

  18. Mitral Valve Prolapse

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ...

  19. Mitral Valve Disease

    Science.gov (United States)

    ... clots, but they also are less durable than mechanical valves and may need to be replaced in the future. Like mitral valve repair, replacement can be done minimally invasively or with traditional open heart surgery. Your medical team will discuss the advantages ...

  20. Image-based mass-spring model of mitral valve closure for surgical planning

    Science.gov (United States)

    Hammer, Peter E.; Perrin, Douglas P.; del Nido, Pedro J.; Howe, Robert D.

    2008-03-01

    Surgical repair of the mitral valve is preferred in most cases over valve replacement, but replacement is often performed instead due to the technical difficulty of repair. A surgical planning system based on patient-specific medical images that allows surgeons to simulate and compare potential repair strategies could greatly improve surgical outcomes. In such a surgical simulator, the mathematical model of mechanics used to close the valve must be able to compute the closed state quickly and to handle the complex boundary conditions imposed by the chords that tether the valve leaflets. We have developed a system for generating a triangulated mesh of the valve surface from volumetric image data of the opened valve. We then compute the closed position of the mesh using a mass-spring model of dynamics. The triangulated mesh is produced by fitting an isosurface to the volumetric image data, and boundary conditions, including the valve annulus and chord endpoints, are identified in the image data using a graphical user interface. In the mass-spring model, triangle sides are treated as linear springs, and sides shared by two triangles are treated as bending springs. Chords are treated as nonlinear springs, and self-collisions are detected and resolved. Equations of motion are solved using implicit numerical integration. Accuracy was assessed by comparison of model results with an image of the same valve taken in the closed state. The model exhibited rapid valve closure and was able to reproduce important features of the closed valve.

  1. Torque limited drive for manual valves

    Science.gov (United States)

    Elliott, Philip G.; Underwood, Daniel E.

    1989-01-01

    The present invention is directed to a torque-limiting handwheel device for preventing manual valves from being damaged due to the application of excessive torque during the opening or closing operation of the valves. Torque can only be applied when ridges in the handwheel assembly engage in channels machined in the face of the baseplate. The amount of torque required for disengagement of the ridges from the channels is determined by the force exerted by various Bellville springs and the inclination of the side faces of the channels.

  2. Autonomous valve for detection of biopolymer degradation

    DEFF Research Database (Denmark)

    Keller, Stephan Urs; Noeth, Nadine-Nicole; Fetz, Stefanie

    2009-01-01

    We present a polymer microvalve that allows the detection of biopolymer degradation without the need of external energy. The valve is based on a polymer container filled with a colored marker solution and closed by a thin lid. This structure is covered by a film of poly(L-lactide) and degradation...... of the biopolymer triggers the release of the color which is detected visually. The autonomous valve has potential for the fast testing of biopolymer degradation under various environmental conditions or by specific enzymes....

  3. Evaluation of mitral valve replacement anchoring in a phantom

    Science.gov (United States)

    McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.

    2012-02-01

    Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.

  4. The living aortic valve: From molecules to function

    Science.gov (United States)

    Chester, Adrian H.; El-Hamamsy, Ismail; Butcher, Jonathan T.; Latif, Najma; Bertazzo, Sergio; Yacoub, Magdi H.

    2014-01-01

    The aortic valve lies in a unique hemodynamic environment, one characterized by a range of stresses (shear stress, bending forces, loading forces and strain) that vary in intensity and direction throughout the cardiac cycle. Yet, despite its changing environment, the aortic valve opens and closes over 100,000 times a day and, in the majority of human beings, will function normally over a lifespan of 70–90 years. Until relatively recently heart valves were considered passive structures that play no active role in the functioning of a valve, or in the maintenance of its integrity and durability. However, through clinical experience and basic research the aortic valve can now be characterized as a living, dynamic organ with the capacity to adapt to its complex mechanical and biomechanical environment through active and passive communication between its constituent parts. The clinical relevance of a living valve substitute in patients requiring aortic valve replacement has been confirmed. This highlights the importance of using tissue engineering to develop heart valve substitutes containing living cells which have the ability to assume the complex functioning of the native valve. PMID:25054122

  5. Transcatheter aortic valve implantation for bicuspid aortic valve stenosis.

    Science.gov (United States)

    Hamdan, Ashraf; Kornowski, Ran

    2015-08-01

    In Preprocedural CT, patients with BAV have larger aortic annulus perimeters, and more calcified valves compared with TAV. In patients with BAV, self-expandable valves were under-expand and balloon-expandable valves have a trend toward increased rates of postimplantation AR grade. Self-expandable valves have higher postprocedural gradient in BAV compared with TAV. © 2015 Wiley Periodicals, Inc.

  6. Development and multiplexed control of latching pneumatic valves using microfluidic logical structures.

    Science.gov (United States)

    Grover, William H; Ivester, Robin H C; Jensen, Erik C; Mathies, Richard A

    2006-05-01

    Novel latching microfluidic valve structures are developed, characterized, and controlled independently using an on-chip pneumatic demultiplexer. These structures are based on pneumatic monolithic membrane valves and depend upon their normally-closed nature. Latching valves consisting of both three- and four-valve circuits are demonstrated. Vacuum or pressure pulses as short as 120 ms are adequate to hold these latching valves open or closed for several minutes. In addition, an on-chip demultiplexer is demonstrated that requires only n pneumatic inputs to control 2(n-1) independent latching valves. These structures can reduce the size, power consumption, and cost of microfluidic analysis devices by decreasing the number of off-chip controllers. Since these valve assemblies can form the standard logic gates familiar in electronic circuit design, they should be useful in developing complex pneumatic circuits.

  7. Blade Vibration Measurement System

    Science.gov (United States)

    Platt, Michael J.

    2014-01-01

    The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.

  8. Conical seat shut off valve

    Science.gov (United States)

    Farner, Bruce R. (Inventor)

    2012-01-01

    A valve includes a housing defining a bore having an inlet and extending along a longitudinal axis. A head is attached to the housing and defines a head passage having an outlet. A piston is disposed within the bore and includes a piston passage extending through the piston along the longitudinal axis. The piston is moveable between a closed position in which a sealing end of the piston abuts a seat of the head to close fluid communication through the piston passage and an open position in which the sealing end of the piston is axially spaced along the longitudinal axis from the seat of the head to permit fluid communication through the piston passage between the inlet and the outlet. The housing defines an equalizing chamber in fluid communication with the head passage for damping movement of the piston.

  9. Electrical Textile Valves for Paper Microfluidics.

    Science.gov (United States)

    Ainla, Alar; Hamedi, Mahiar M; Güder, Firat; Whitesides, George M

    2017-10-01

    This paper describes electrically-activated fluidic valves that operate based on electrowetting through textiles. The valves are fabricated from electrically conductive, insulated, hydrophobic textiles, but the concept can be extended to other porous materials. When the valve is closed, the liquid cannot pass through the hydrophobic textile. Upon application of a potential (in the range of 100-1000 V) between the textile and the liquid, the valve opens and the liquid penetrates the textile. These valves actuate in less than 1 s, require low energy (≈27 µJ per actuation), and work with a variety of aqueous solutions, including those with low surface tension and those containing bioanalytes. They are bistable in function, and are, in a sense, the electrofluidic analog of thyristors. They can be integrated into paper microfluidic devices to make circuits that are capable of controlling liquid, including autonomous fluidic timers and fluidic logic. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  11. FAILURE MODE AND EFFECT ANALYSIS (FMEA) OF BUTTERFLY VALVE IN OIL AND GAS INDUSTRY

    OpenAIRE

    MUHAMMAD AMIRUL BIN YUSOF; NAZLIN HANIE BT ABDULLAH

    2016-01-01

    Butterfly valves are mostly used in various industries such as oil and gas plant. This valve operates with rotating motion using pneumatic system. Rotating actuator turns the disc either parallel or perpendicular to the flow. When the valve is fully open, the disc is rotated a quarter turn so that it allows free passage of the fluid and when fully closed, the disc rotated a quarter turns to block the fluid. The primary failure modes for valves are the valve leaks to environment through flange...

  12. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    OpenAIRE

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mecha...

  13. Vibrating minds

    CERN Document Server

    2009-01-01

    Ed Witten is one of the leading scientists in the field of string theory, the theory that describes elementary particles as vibrating strings. This week he leaves CERN after having spent a few months here on sabbatical. His wish is that the LHC will unveil supersymmetry.

  14. Mitral valve surgery - open

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... stroke. Valves made from human or animal tissue fail over time. They have an average lifespan of ...

  15. Valve Repair or Replacement

    Science.gov (United States)

    ... valve surgery can be done using a robot. Robotic surgery does not require a large incision in the ... The Texas Heart Institute has a robot. With robotic surgery, the surgeon has a control console, a side ...

  16. Aortic Valve Regurgitation

    Science.gov (United States)

    ... valves. Rheumatic fever. Rheumatic fever — a complication of strep throat and once a common childhood illness in the ... a severe sore throat, see a doctor. Untreated strep throat can lead to rheumatic fever. Fortunately, strep throat ...

  17. An approach to fault diagnosis of reciprocating compressor valves using Teager-Kaiser energy operator and deep belief networks

    NARCIS (Netherlands)

    Tran, V.T.; Thobiani, Faisal Al; Ball, Andrew David

    2014-01-01

    This paper presents an approach to implement vibration, pressure, and current signals for fault diagnosis of the valves in reciprocating compressors. Due to the complexity of structure and motion of such compressor, the acquired vibration signal normally involves transient impacts and noise. This

  18. Effects of pressure and temperature on gate valve unwedging

    Energy Technology Data Exchange (ETDEWEB)

    Damerell, P.S.; Harrison, D.H.; Hayes, P.W.; Simons, J.W.; Walker, T.A.

    1996-12-01

    The stem thrust required to unwedge a gate valve is influenced by the pressure and temperature when the valve is closed and by the changes in these conditions between closure and opening. {open_quotes}Pressure locking{close_quotes} and {open_quotes}thermal binding{close_quotes} refer to situations where pressure and temperature effects cause the unwedging load to be much higher than normal. A model of these phenomena has been developed. Wedging (closure) is modeled as developing an {open_quotes}interference{close_quotes} between the disk and its seat rings in the valve. The effects of pressure and temperature are analyzed to determine the change in this disk-to-seat {open_quotes}interference{close_quotes}. Flexibilities, of the disk, body, stem and yoke strongly influence the unwedging thrust. Calculations and limited comparisons to data have been performed for a range of valve designs and scenarios. Pressure changes can increase the unwedging load when there is either a uniform pressure decrease, or a situation where the bonnet pressure exceeds the pressures in the adjacent piping. Temperature changes can increase the unwedging load when: (1) valve closure at elevated system temperature produces a delayed stem expansion, (2) a temperature increase after closure produces a bonnet pressure increase, or (3) a temperature change after closure produces an increase in the disk-to-seat {open_quotes}interference{close_quotes} or disk-to-seat friction.

  19. Case Report: Prothesis-patient mismatch after aortic valve replacement.

    Science.gov (United States)

    Rodriguez-Ospina, Luis; Garcia-Morell, Juan; Rodriguez-Monserrate, Carla P; Valentin-Nieves, Julio

    2015-01-01

    Valve replacement is the standard surgical treatment of diseased valves that cannot be repaired. The main goal of replacement is to exchange the diseased valve with one that has the engineering and hemodynamics as close as possible to the disease free native valve. However due to mechanical and fluid dynamic constraints all prosthetic heart valves (PHVs) are smaller than normal and thus are inherently stenotic. This represents a challenge when it comes time to replace a valve. The correct valve with the correct and matching profile has to be selected before the procedure to avoid possible complications. It is well recognized that patients are also prone to patient-prosthesis mismatch at long term which could have consequences in the clinical outcomes (1). The evaluation of patient-prosthesis mismatch (PPM) has not been sufficiently emphasized in common practice. Failure to recognize this fact may lead to significant hemodynamic impairment and worsening of the clinical status over the time. Making efforts to identifying patients at risk may decrease the prevalence of PPM, the economic impact to our health system, the morbidity and mortality involved in these cases as well as creates efforts to standardized pre-operative protocols to minimized risk of PPM. We present a case of a 78 years old male patient who underwent aortic valve replacement due severe aortic stenosis, afterwards his clinical course got complicated with several admissions for shortness of breath and decompensated congestive heart failure (CHF).

  20. Classification of heart valve condition using acoustic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Prosthetic heart valves and the many great strides in valve design have been responsible for extending the life spans of many people with serious heart conditions. Even though the prosthetic valves are extremely reliable, they are eventually susceptible to long-term fatigue and structural failure effects expected from mechanical devices operating over long periods of time. The purpose of our work is to classify the condition of in vivo Bjork-Shiley Convexo-Concave (BSCC) heart valves by processing acoustic measurements of heart valve sounds. The structural failures of interest for Bscc valves is called single leg separation (SLS). SLS can occur if the outlet strut cracks and separates from the main structure of the valve. We measure acoustic opening and closing sounds (waveforms) using high sensitivity contact microphones on the patient`s thorax. For our analysis, we focus our processing and classification efforts on the opening sounds because they yield direct information about outlet strut condition with minimal distortion caused by energy radiated from the valve disc.

  1. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2005-04-27

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. As a result of the lower than expected performance of the MR damper noted last quarter, several additional tests were conducted. These dealt with possible causes of the lack of dynamic range observed in the testing: additional damping from the oil in the Belleville springs; changes in properties of the MR fluid; and, residual magnetization of the valve components. Of these, only the last was found to be significant. By using a laboratory demagnetization apparatus between runs, a dynamic range of 10:1 was achieved for the damper, more than adequate to produce the needed improvements in drilling. Additional modeling was also performed to identify a method of increasing the magnetic field in the damper. As a result of the above, several changes were made in the design. Additional circuitry was added to demagnetize the valve as the field is lowered. The valve was located to above the Belleville springs to reduce the load placed upon it and offer a greater range of materials for its construction. In addition, to further increase the field strength, the coils were relocated from the mandrel to the outer housing. At the end of the quarter, the redesign was complete and new parts were on order. The project is approximately three months behind schedule at this time.

  2. Internal combustion engine with rotary valve assembly having variable intake valve timing

    Science.gov (United States)

    Hansen, Craig N.; Cross, Paul C.

    1995-01-01

    An internal combustion engine has rotary valves associated with movable shutters operable to vary the closing of intake air/fuel port sections to obtain peak volumetric efficiency over the entire range of speed of the engine. The shutters are moved automatically by a control mechanism that is responsive to the RPM of the engine. A foot-operated lever associated with the control mechanism is also used to move the shutters between their open and closed positions.

  3. Experimental Validation of Modelled Fluid Forces in Fast Switching Hydraulic On/Off Valves

    DEFF Research Database (Denmark)

    Nørgård, Christian; Bech, Michael Møller; Roemer, Daniel Beck

    2015-01-01

    A prototype of a fast switching valve for a digital hydraulic machine has been designed and manufactured. The valve is composed of an annular seat plunger connected with a moving coil actuator as the force producing element. The valve prototype is designed for flow rates of 600 l/min with less than...... approaches the closed position. Fast switching is essential for digital hydraulic machines to achieve a high efficiency. As the fluid forces influences the response obtaining an accurate model is important. To validate the model tests are carried out on the prototype where the valve is closed, both...

  4. The challenges of managing rheumatic disease of the mitral valve in Jamaica.

    Science.gov (United States)

    Little, Sherard G

    2014-12-01

    Between January, 2009 and December, 2013, 84 patients were identified who underwent isolated mitral valve surgery in Jamaica at The University Hospital of the West Indies and The Bustamante Hospital for Children. The most common pathology requiring surgery was rheumatic heart disease, accounting for 84% of the procedures performed. The majority of patients had regurgitation of the mitral valve (67%), stenosis of the mitral valve (22%), and mixed mitral valve disease (11%). The most common procedure performed was replacement of the mitral valve (69%), followed by mitral valve repair (29%). Among the patients, one underwent closed mitral commissurotomy. The choice of procedure differed between age groups. In the paediatric population (mitral valve (89%). In the adult population (18 years and above), the majority of patients underwent mitral valve replacement (93%). Overall, of all the patients undergoing replacement of the mitral valve, 89% received a mechanical valve prosthesis, whereas 11% received a bioprosthetic valve prosthesis. Of the group of patients who underwent mitral valve repair for rheumatic heart disease, 19% required re-operation. The average time between initial surgery and re-operation was 1.2 years. Rheumatic fever and rheumatic heart disease remain significant public health challenges in Jamaica and other developing countries. Focus must remain on primary and secondary prevention strategies in order to limit the burden of rheumatic valvulopathies. Attention should also be directed towards improving access to surgical treatment for young adults.

  5. Airbag vent valve and system

    Science.gov (United States)

    Peterson, Leslie D. (Inventor); Zimmermann, Richard E. (Inventor)

    2001-01-01

    An energy absorbing airbag system includes one or more vent valve assemblies for controlling the release of airbag inflation gases to maintain inflation gas pressure within an airbag at a substantially constant pressure during a ride-down of an energy absorbing event. Each vent valve assembly includes a cantilever spring that is flat in an unstressed condition and that has a free end portion. The cantilever spring is secured to an exterior surface of the airbag housing and flexed to cause the second free end portion of the cantilever spring to be pressed, with a preset force, against a vent port or a closure covering the vent port to seal the vent port until inflation gas pressure within the airbag reaches a preselected value determined by the preset force whereupon the free end portion of the cantilever spring is lifted from the vent port by the inflation gases within the airbag to vent the inflation gases from within the airbag. The resilience of the cantilever spring maintains a substantially constant pressure within the airbag during a ride-down portion of an energy absorbing event by causing the cantilever spring to vent gases through the vent port whenever the pressure of the inflation gases reaches the preselected value and by causing the cantilever spring to close the vent port whenever the pressure of the inflation gases falls below the preselected value.

  6. How Is Heart Valve Disease Treated?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  7. How Is Heart Valve Disease Diagnosed?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  8. When a Heart Murmur Signals Valve Disease

    Science.gov (United States)

    ... Order AHA Brochures Your Heart Valve Surgery Your Mitral Valve Prolapse Innocent Heart Murmurs If Your Child Has a Congenital Heart Defect See all of our brochures Valve Disease Resources Patient Guide: Understanding Your Heart Valve Problem | ...

  9. System for remotely servicing a top loading captive ball valve

    Science.gov (United States)

    Berry, S.M.; Porter, M.L.

    1996-06-25

    An attachment for facilitating servicing of a valve is disclosed including: an assembly composed of a valve seat defining a flow path, a flow control member movable relative to the valve seat for blocking or unblocking the valve seat, and a control device including a stem coupled to the flow control member and operable for moving the flow control member relative to the valve seat; a housing for receiving the assembly, the housing having an opening via which the assembly can be removed from, and installed in, the housing, and the housing having a plurality of threaded studs which surround the opening and project away from the housing; a valve housing cover for closing and sealing the opening in the housing, the cover having a first bore for passage of the stem of the control device when the assembly is installed in the housing and a plurality of second bores each located for passage of a respective stud when the cover closes the opening in the housing. A plurality of threaded nuts are engageable with the studs for securing the cover to the housing when the cover closes the opening in the housing, wherein the attachment comprises: a plurality of nut guide devices removable from the housing and each operatively associated with a respective stud for retaining a respective nut and guiding the respective nut into alignment with the respective stud to enable the respective nut to be rotated into engagement with the respective stud; and aligning the nut guide devices with the studs. 7 figs.

  10. Pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, E.M.

    1996-12-01

    Pressure locking and thermal binding represent potential common mode failure mechanisms that can cause safety-related power-operated gate valves to fail in the closed position, thus rendering redundant safety-related systems incapable of performing their safety functions. Supplement 6 to Generic Letter 89-10, {open_quotes}Safety-Related Motor-Operated Gate Valve Testing and Surveillance,{close_quotes} provided an acceptable approach to addressing pressure locking and thermal binding of gate valves. More recently, the NRC has issued Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves,{close_quotes} to request that licensees take certain actions to ensure that safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases. Over the past two years, several plants in Region I determined that valves in certain systems were potentially susceptible to pressure locking and thermal binding, and have taken various corrective actions. The NRC Region I Systems Engineering Branch has been actively involved in the inspection of licensee actions in response to the pressure locking and thermal binding issue. Region I continues to maintain an active involvement in this area, including participation with the Office of Nuclear Reactor Regulation in reviewing licensee responses to Generic Letter 95-07.

  11. Vibration Damping Circuit Card Assembly

    Science.gov (United States)

    Hunt, Ronald Allen (Inventor)

    2016-01-01

    A vibration damping circuit card assembly includes a populated circuit card having a mass M. A closed metal container is coupled to a surface of the populated circuit card at approximately a geometric center of the populated circuit card. Tungsten balls fill approximately 90% of the metal container with a collective mass of the tungsten balls being approximately (0.07) M.

  12. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  13. Diagnosis of mitral valve prolapse by X-ray CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, Yoshiaki; Inagaki, Yoshiaki

    1986-12-01

    To evaluate the usefulness of enhanced X-ray CT and gating magnetic resonance imaging (MRI) for diagnosing mitral valve prolapse, three patients with this abnormality and several controls were examined by these two methods. The mitral valve was not recognized by X-ray CT except a few cases with thickened mitral valve. However, MRI could demonstrate clearly the mitral leaflets and annulus in many subjects. In transverse MR imaging of the subjects without valvular disease, the closed mitral valve showed V-shaped appearance in the left ventricle during systole. In a patient with marked mitral valve prolapse, MRI revealed buckling of the posterior mitral leaflet into the left atrium, and in two other patients with mild mitral valve prolapse, MRI demonstrated displacement of coaptation of the anterior leaflet toward the left atrium. These results suggest MRI is a useful method for diagnosing mitral valve prolapse.

  14. Oil Stiction in Fast Switching Annular Seat Valves for Digital Displacement Fluid Power Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    Digital Displacement (DD) fluid power machines utilizes electronically controlled seat valves connected to pressure chambers to obtain variable displacement with high operational efficiency and high bandwidth. To achieve high efficiency, fast valve switching is essential and all aspects related...... to the dynamic behaviour of the seat valves must be considered to optimize the machine efficiency. A significant effect influencing the valves switching performance is the presence of oil stiction when separating the contact surfaces in valve opening movement. This oil stiction force is limited by cavitation...... for low pressure levels, e.g. valves connected to the low pressure manifold, however for valves operated at higher pressure levels, the oil stiction force is dominating when the separating surfaces are close to contact. This paper presents an analytic solution to the oil stiction force for annular seat...

  15. Low radiation dose non-contrast cardiac CT: is it of value in the evaluation of mechanical aortic valve

    Energy Technology Data Exchange (ETDEWEB)

    Bazeed, Mohamed Fayez (Dept. of Diagnostic Radiology, Faculty of Medicine, Mansoura Univ. (Egypt)), email: m_bazeed@yahoo.com; Moselhy, Mohamed Saleh (Cardiology Dept. Faculty of Medicine, Suez Canal Univ. (Egypt)); Rezk, Ahmad Ibrahim (Dept. of Cardiac Surgery, Faculty of Medicine, Aim Shams Univ. (Egypt)); Al-Murayeh, Mushabab Ayedh (Dept. of Cardiac Services, Armed Forces Hospitals Southern Region (Saudi Arabia))

    2012-05-15

    Background: Prosthetic bileaflet mechanical valve function has been traditionally evaluated using echocardiography and fluoroscopy. Multidetector computed tomography (MDCT) is a novel technique for cardiac evaluation. Purpose: To evaluate bileaflet mechanical aortic valves using a low-milliampere (mA), non-contrast MDCT protocol with a limited scan range. Material and Methods: Forty patients with a bileaflet mechanical aortic valve were evaluated using a non-contrast, low-mA, ECG-gated 64 MDCT protocol with a limited scan range. MDCT findings of opening and closing valve angles were correlated to fluoroscopy and echocardiography. Also, the valve visibility was evaluated on MDCT and fluoroscopy according to a 3-point grading scale. Results: The visualization score with the MDCT was significantly superior to the fluoroscopy (3 vs. 2.7). A strong correlation was noted between the opening (r = 0.82) and closing (r = 0.96) valve angles with MDCT and fluoroscopy without a statistically significant difference (P = 0.31 and 0.16, respectively). The mean effective radiation dose of the suggested protocol was 4 +- 0.5 mSv. Five valves were evaluated using transesophageal echocardiography because the valves were difficult to evaluate with transthoracic echocardiography, and all of these valves were evaluated optimally with MDCT. A high-pressure gradient was noted in nine valves, and the MDCT showed that seven of these valves inadequately opened, and two valves opened well, which resulted in patient valve mismatch. Incomplete valve closure was noted in five valves, and the echocardiography showed significant transvalvular regurgitation in all five valves. Conclusion: MDCT can provide a precise measurement of valve function and can potentially evaluate high-pressure gradients and transvalvular regurgitation

  16. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... diseases of the tricuspid valve are regurgitation and stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid ... the tricuspid valve may also be needed. Tricuspid Stenosis Tricuspid stenosis is a narrowing or blockage of ...

  17. Options for Heart Valve Replacement

    Science.gov (United States)

    ... valve: Aortic regurgitation , (sometimes referred to as aortic insufficiency) is another common valve problem that may require ... allows oxygenated blood to flow backwards into the lungs instead of continuing through the heart as it ...

  18. Design of Epoxy based Resin Composites for Automotive Applications: A Case Study on IC Engine Valve Guide

    Science.gov (United States)

    Sidhu, J. S.; Lathkar, G. S.; Sharma, S. B.

    2018-01-01

    The present attempt in this project is to reduce the vibrations, temperature due to friction, noise and weight of I C engine valve guide by replacing conventional metal valve guide with composite valve guide. Composite materials have been used in automotive components because of their properties such as low weight, high specific stiffness, corrosion resistance, ability to produce complex shapes, high specific strength and good impact energy absorption etc. The Internal combustion engine valve guides are the parts that support the valves in the cylinder head, besides this it keeps lubricating oil from getting sucked into the combustion chamber past the intake valve stem, it keeps exhaust gases from getting into the crankcase past the exhaust valve stem and it also keeps the valve face in perfect alignment with the valve seat. A valve guide test rig is indigenously fabricated. Valve guides are manufactured using the developed composite material (Resin ARL-136, Hardener AH-126 and 4 vol% WS2), on a CNC lathe. The performance of the developed composite guide under varied conditions of speeds, that is, fixed change in rpm and modulated changes in rpm is assessed. Noise, temperature and vibrations are measured. The experimental data revealed that contribution of composite guide in respect of acceleration, velocity and displacement components of vibration is not substantial. A substantial reduction in noise levels is seen. As far as temperature rise due to friction is concerned maximum components fail at elevated temperatures, with composite guides the temperature generated due to friction at higher speeds is less, a considerable weight reduction is also observed.

  19. Echocardiography of the mitral valve

    OpenAIRE

    Omran, A.S.; Arifi, A.A.; Mohamed, A.A.

    2010-01-01

    Mitral valve disease is the second most common valvular heart disease after the aortic valve worldwide. Mitral valve has historically been a structure of interest by pioneers in echocardiography. One of the earliest applications of echocardiography was in the diagnosis of valvular heart disease, particularly mitral stenosis. In this review we wish to take the reader through the structural and hemodynamic evaluation of the normal mitral valve.

  20. Valve Concepts for Microfluidic Cell Handling

    Directory of Open Access Journals (Sweden)

    M. Grabowski

    2010-01-01

    Full Text Available In this paper we present various pneumatically actuated microfluidic valves to enable user-defined fluid management within a microfluidic chip. To identify a feasible valve design, certain valve concepts are simulated in ANSYS to investigate the pressure dependent opening and closing characteristics of each design. The results are verified in a series of tests. Both the microfluidic layer and the pneumatic layer are realized by means of soft-lithographic techniques. In this way, a network of channels is fabricated in photoresist as a molding master. By casting these masters with PDMS (polydimethylsiloxane we get polymeric replicas containing the channel network. After a plasma-enhanced bonding process, the two layers are irreversibly bonded to each other. The bonding is tight for pressures up to 2 bar. The valves are integrated into a microfluidic cell handling system that is designed to manipulate cells in the presence of a liquid reagent (e.g. PEG – polyethylene glycol, for cell fusion. For this purpose a user-defined fluid management system is developed. The first test series with human cell lines show that the microfluidic chip is suitable for accumulating cells within a reaction chamber, where they can be flushed by a liquid medium.

  1. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  2. Urban vibrations

    DEFF Research Database (Denmark)

    Morrison, Ann; Knudsen, L.; Andersen, Hans Jørgen

    2012-01-01

      lab   studies   in   that   we   found   a   decreased   detection   rate   in   busy   environments.   Here   we   test   with   a   much   larger   sample   and   age   range,   and   contribute   with   the   first   vibration  sensitivity  testing  outside  the  lab  in  an  urban   public...

  3. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  4. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...... similar to the one achieved by the expensive and time-consuming CFD calculations. So CFD is only used in case of entirely new designs or where a very detailed knowledge of the flow is required. Even though rules of thumb are useful for those, who have developed them, Danfoss needs an objective and general...

  5. Edwards SAPIEN 3 valve.

    Science.gov (United States)

    Binder, Ronald K; Rodés-Cabau, Josep; Wood, David A; Webb, John G

    2012-09-01

    Building on the established success with the SAPIEN, SAPIEN XT and earlier prototypic transcatheter heart valves (THV) the newest balloon-expandable valve incorporates a number of new and enhanced features intended to reduce the risk of vascular injury, to reduce paravalvular regurgitation, and to facilitate rapid and accurate positioning and implantation. The SAPIEN 3 THV incorporates a cobalt chromium stent, bovine pericardial leaflets, and both an inner and new outer polyethylene terephthalate sealing cuff. The delivery system incorporates an active three-dimensional coaxial positioning catheter, and is compatible with a 14 Fr expandable sheath.

  6. Modeling and performance evaluation of an electromechanical valve actuator for a camless IC engine

    Energy Technology Data Exchange (ETDEWEB)

    Mohamed, Eid [Automotive and Tractors Engineering, Faculty of Engineering, Helwan University, Cairo (Egypt)

    2012-07-01

    Valve train control is one of the best strategies for optimizing efficiency and emissions of Internal Combustion (IC) engines. Applications of solenoid valve actuators in (IC) engines can facilitate operations such as variable valve timing and variable valve lifting for improved the engine performance, fuel economy and reduce emission, the electromechanical valve actuator (EMVA) uses solenoid to actuate valve movement independently for the application of (IC) engine. In this work presents the effects of design and operating parameters on the system dynamic performances of the actuator and the proposed an (EMVA) structure by incorporating the hybrid magneto-motive force (MMF) implementation in which the magnetic flux is combined by the coil excitation and permanent magnets. A two-degree-of-freedom lumped parameter model is used to simulate the response of valve actuator system in the opening and closing. The model and control of an electromagnetic valve (EMV) are described. This is done using electromagnetic force to open and close the valve and a controller regulates the motion specifications required. The developments controller is based on a state-space description of the actuator that is derived based on physical principles and parameter identification. Linear-quadratic regulator design (LQR) optimal control is designed with the evaluation reasonable the performance and energy of (EMV) valve are obtained with the design.

  7. Wax microfluidics light-addressable valve with multiple actuation

    Science.gov (United States)

    Díaz-González, M.; Boix, G.; Fernández-Sánchez, C.; Baldi, A.

    2017-05-01

    This work reports on the design, fabrication and performance of a novel light-actuated wax microvalve. This valve is capable of multiple-actuation (30 and 15 open-close cycles in air and water, correspondingly), shows a fast response (<=500 ms) and has a low energy-consumption per actuation (<=1 J). The valve is inherently latched in both open and close states and is leak-proof to at least 80 kPa. It is actuated (both open and close) by light pulses from an external LED. Many valves (< 100 cm2) can be easily integrated in a single chip with a wax microfluidics technology. Fabrication is based on a low-cost and fast prototyping process compatible with the presence of temperature sensitive biocomponents.

  8. Ball valve design for solid withdrawal service in coal liquefaction

    Science.gov (United States)

    Patton, Alexander J.

    1981-02-01

    Valves used for drawdown of the solids produced in the coal liquefaction process must be designed to operate at high temperatures and must prevent the buildup of solids within the valve internals to insure operability. Consideration must also be given to materials used for seating surfaces in terms of being able to withstand abrasion. Research into the design and materials for this application results in a new ball valve design with a special inlet port liner and O-ring seal. A prototype valve was built and put in service in a small scale, experimental coal liquefaction plant. For comparative purposes a standard design valve was also used, with both valves being subjected to over 1000 open/close cycles, after which both valves were removed, tested, and disassembled for inspection. The results of this experimental program will be presented, including process parameters, service conditions, and material evaluation. Particular emphasis will be placed on wear of seating surfaces and the effects of process material on the physical properties of seal and packing materials.

  9. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    Science.gov (United States)

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Fluid Mechanics of Heart Valves and Their Replacements

    Science.gov (United States)

    Sotiropoulos, Fotis; Le, Trung Bao; Gilmanov, Anvar

    2016-01-01

    As the pulsatile cardiac blood flow drives the heart valve leaflets to open and close, the flow in the vicinity of the valve resembles a pulsed jet through a nonaxisymmetric orifice with a dynamically changing area. As a result, three-dimensional vortex rings with intricate topology emerge that interact with the complex cardiac anatomy and give rise to shear layers, regions of recirculation, and flow instabilities that could ultimately lead to transition to turbulence. Such complex flow patterns, which are inherently valve- and patient-specific, lead to mechanical forces at scales that can cause blood cell damage and thrombosis, increasing the likelihood of stroke, and can trigger the pathogenesis of various life-threatening valvular heart diseases. We summarize the current understanding of flow phenomena induced by heart valves, discuss their linkage with disease pathways, and emphasize the research advances required to translate in-depth understanding of valvular hemodynamics into effective patient therapies.

  11. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  12. Aortic valve surgery - open

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  13. Theory of vibration protection

    CERN Document Server

    Karnovsky, Igor A

    2016-01-01

    This text is an advancement of the theory of vibration protection of mechanical systems with lumped and distributed parameters. The book offers various concepts and methods of solving vibration protection problems, discusses the advantages and disadvantages of different methods, and the fields of their effective applications. Fundamental approaches of vibration protection, which are considered in this book, are the passive, parametric and optimal active vibration protection. The passive vibration protection is based on vibration isolation, vibration damping and dynamic absorbers. Parametric vibration protection theory is based on the Shchipanov-Luzin invariance principle. Optimal active vibration protection theory is based on the Pontryagin principle and the Krein moment method. The book also contains special topics such as suppression of vibrations at the source of their occurrence and the harmful influence of vibrations on humans. Numerous examples, which illustrate the theoretical ideas of each chapter, ar...

  14. Micro-valve pump light valve display

    Science.gov (United States)

    Lee, Yee-Chun

    1993-01-01

    A flat panel display incorporates a plurality of micro-pump light valves (MLV's) to form pixels for recreating an image. Each MLV consists of a dielectric drop sandwiched between substrates, at least one of which is transparent, a holding electrode for maintaining the drop outside a viewing area, and a switching electrode from accelerating the drop from a location within the holding electrode to a location within the viewing area. The sustrates may further define non-wetting surface areas to create potential energy barriers to assist in controlling movement of the drop. The forces acting on the drop are quadratic in nature to provide a nonlinear response for increased image contrast. A crossed electrode structure can be used to activate the pixels whereby a large flat panel display is formed without active driver components at each pixel.

  15. An air-pressure-free elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis

    Science.gov (United States)

    Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Rivera, Andrew; Birdsell, Dawn N.; Wagner, David M.; Zenhausern, Frederic

    2015-12-01

    We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30-100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis.

  16. Curved butterfly bileaflet prosthetic cardiac valve

    Energy Technology Data Exchange (ETDEWEB)

    McQueen, D.M.; Peskin, C.S.

    1991-06-25

    An annular valve body having a central passageway for the flow of blood with two curved leaflets is described. Each of the leaflets is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance. 26 figures.

  17. Curved butterfly bileaflet prosthetic cardiac valve

    Energy Technology Data Exchange (ETDEWEB)

    McQueen, David M. (185 Hillside Ave., Chatham, NJ 07928); Peskin, Charles S. (186 Harrard Dr., Hartsdale, NY 10530)

    1991-06-25

    An annular valve body having a central passageway for the flow of blood therethrough with two curved leaflets each of which is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance.

  18. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  19. First Reported Successful Femoral Valve-in-Valve Transcatheter Aortic Valve Replacement Using the Edwards Sapien 3 Valve.

    Science.gov (United States)

    Fournier, Stephane; Monney, Pierre; Roguelov, Christan; Zuffi, Andrea; Iglesias, Juan F; Qanadli, Salah D; Courbon, Cecile; Eeckhout, Eric; Muller, Olivier

    2015-10-01

    Management of degenerated aortic valve bioprosthesis classically requires redo surgery, but transcatheter aortic valve-in-valve implantation is becoming a valid alternative in selected cases. In the case of a degenerated Mitroflow bioprosthesis, TAVR is associated with an additional challenge due to a specific risk of coronary occlusion. We aimed to assess the safety and feasibility of transfemoral valve-in-valve implantation of the new Edwards Sapien 3 (Edwards Lifesciences) in a degenerated Mitroflow bioprosthesis (Sorin Group, Inc). We report here the safety and feasibility of transfemoral valve-in-valve implantation of a 23 mm Edwards Sapien 3 in a degenerated 25 mm Mitroflow valve and describe the specific assessment of the risk of coronary obstruction using a multi-imaging modality. The final result showed an absence of aortic regurgitation and a mean transvalvular gradient of 14 mm Hg. The patient had no major adverse cardiovascular events at 30-day follow-up. Transcatheter valve-in-valve implantation of an Edwards Sapien 3 in a degenerated Mitroflow is feasible and safe, considering a careful assessment of the risk of coronary obstruction with Mitroflow bioprosthesis due to leaflets mounted externally to the stent.

  20. Mechanical Valve Replacement: Early Results

    Directory of Open Access Journals (Sweden)

    Habib Cakir

    2012-02-01

    Full Text Available Aim: Valve diseases in developing countries like Turkey which often occur as a complication of rheumatic fever are a serious disease. Surgical treatment of valve diseases should be done before irreversible damage to the myocardium occurred. In this study, we aimed to present the early results of mechanical valve replacement operations. Method: A hundred patients with mechanical valve replacement surgery were retrospectively evaluated in Seyhan Application Center attached to our clinic between July 2007 and August 2011. Results: Fifty patients were male and 50 were women. The mean age of patients was 47.88 (18-78. Isolated aortic valve replacement (AVR was performed to 23 patients, isolated mitral valve replacement (MVR was 32, double valve replacement (AVR + MVR was 12, MVR + aortic valve valvuloplasty was 1, AVR + mitral kommissurotomi was 1, AVR + coronary artery bypass graft surgery (CABG was 17, MVR + CABG was 8, MVR + atrial septal defect closure was 2 and Bentall procedure.was 4 patients. In addition, ablation procedure was performed to 5 patients intraoperatively because of preoperative atrial fibrillation. Two patients (2 % died in early postoperative period. Conclusion: Mechanical prosthetic valves are used for surgical treatment of valve disease with low mortality and morbidity in a large group of patients like women that not to think to get pregnant, non advanced age group and patients have less risky for anticoagulation drug in our clinic. [Cukurova Med J 2012; 37(1.000: 49-54

  1. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  2. Integrated predictive maintenance program vibration and lube oil analysis: Part I - history and the vibration program

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, H.

    1996-12-01

    This paper is the first of two papers which describe the Predictive Maintenance Program for rotating machines at the Palo Verde Nuclear Generating Station. The organization has recently been restructured and significant benefits have been realized by the interaction, or {open_quotes}synergy{close_quotes} between the Vibration Program and the Lube Oil Analysis Program. This paper starts with the oldest part of the program - the Vibration Program and discusses the evolution of the program to its current state. The {open_quotes}Vibration{close_quotes} view of the combined program is then presented.

  3. Fast-Valving of Large Steam Turbine Units as a Means of Power System Security Enhancement

    Directory of Open Access Journals (Sweden)

    Bogdan Sobczak

    2014-03-01

    Full Text Available Fast-valving assists in maintaining system stability following a severe transmission system fault by reducing the turbine mechanical power. Fast-valving consists in rapid closing and opening of steam valves in an adequate manner to reduce the generator accelerating power following the recognition of a severe fault. FV can be an effective and economical method of meeting the performance requirements of a power system in the presence of an increase in wind and solar generation in the power system, newly connected large thermal units and delaying of building new transmission lines. The principle of fast-valving and advantages of applying this technique in large steam turbine units was presented in the paper. Effectiveness of fast-valving in enhancing the stability of the Polish Power Grid was analyzed. The feasibility study of fast-valving application in the 560 MW unit in Kozienice Power Station (EW SA was discussed.

  4. Optimum design of seat region in valves suitable for digital displacement machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    is optimised considering both the mechanical strength during pressure loading and fluid flow restriction in the open valve state. Material stresses are modelled using finite element (FE) analysis including non-linear material behaviour, contact elements and fluid pressure penetrating load, closely reflecting......Digital displacement fluid power is an upcoming technology setting new standards for the achievable efficiency in variable displacement fluid power pumps and motors. In the present work, an annular seat valve suitable for use in digital displacement units is considered, and the valve geometry...... the actual load of the seat valve connected to a fluid pressure chamber. Valve pressure losses are modelled using computational fluid dynamics (CFD). On basis of an overall physical size requirement and material specification, optimum valve geometry and stroke length are given as function of a defined...

  5. Intense Microbubbles Mimicking Mobile Thrombus in a Patient with Prosthetic Mitral Valve

    Directory of Open Access Journals (Sweden)

    Fatma Yılmaz Coşkun

    2017-06-01

    Full Text Available Microbubbles have been presumed as gaseous emboli, which originate during mechanical heart valve closure, but are not seen in bioprosthetic valves. In this report, we presented a cluster of microbubbles mimicking mobile thrombus in a patient with mechanical mitral valve prosthesis. A 30-year-old female with a history of implanted mechanical valve at the mitral position underwent a routine examination. She was asymptomatic and her physical examination was unremarkable. Transthoracic echocardiography showed a mobile thrombus-like mass on the ventricular side of the prosthetic mitral valve moving into the left ventricular outflow tract. However, close examination of images indicated that the mass was in fact intense microbubbles mimicking thrombus. Intense mobile microbubbles can be misdiagnosed as a mobile thrombus. We recommend and underscore the importance of detailed echocardiographic examination in case of mobile mass to avoid misdiagnosis in patients with mechanical heart valves.

  6. Performance Characteristics of an Isothermal Freeze Valve

    Energy Technology Data Exchange (ETDEWEB)

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  7. Tricuspid Valve Replacement, Mechnical vs. Biological Valve, Which Is Better?

    Directory of Open Access Journals (Sweden)

    Haitham Akram Altaani

    2013-06-01

    Full Text Available Background: The initial trial in tricuspid surgery is repair; however, replacement is done whenever the valve is badly diseased. Tricuspid valve replacement comprises 1.7% of all tricuspid valve surgeries. Materials and Methods: The present retrospective study was performed using the medical records of 21 cases who underwent tricuspid valve replacement from January 2002 until the end of December 2010. The mean age of the participants was 52.3±8.8 years and 66.7% were females. In addition, tricuspid valve replacement was associated with mitral valve surgery, aortic valve surgery, and both in 14.3%, 4.8%, and 33.3% of the cases, respectively. Yet, isolated tricuspid valve replacement and redo surgery were performed in 10 cases (47.6% and 8 cases (38.1%, respectively. Besides, trial of repair was done in 14 cases (66.7%. Moreover, biological and mechanical valves were used in 76.2% and 23.8% of the patients, respectively. Results: According to the results, early mortality was 23.8% and one year survival was 66.7%. Moreover, early mortality was caused by right ventricular failure, multiorgan failure, medistinitis, and intracerbral bleeding in 42%, 28.6%, 14.3%, and 14.3% of the cases, respectively. In addition, 57.1% of the deaths had occurred in the cases where the biological valve was used, while 42.9% of the deaths had taken place where the mechanical one was utilized. Conclusions: The patients who require tricuspid valve replacement are usually high risk surgical candidates with early and long term mortality. The findings of the current study showed no significant hemodynamic difference between mechanical and biological valves.

  8. Thermo-electric valve

    Science.gov (United States)

    Chamberland, R. R.; Stanland, A. J.

    1985-02-01

    A thermo-electric valve is described for scuttling floating devices comprising, a cylindrical sleeve affixed to and passing through a bulkhead separating a pressurized medium on one side from a lower pressure space on the other side, a piston moveably mounted within the sleeve bore and exposed to the pressurized medium having a portion thereof blocking the sleeve bore, an O-ring sealing the gap between the piston head and the sleeve bore, a fully compressed spring pressing against the piston, a rigid dielectric washer and a low power resistor holding the piston against the spring. In operation a low current is passed through the resistor, disintegrating it and releasing the spring's stored energy. This actuates the valve by expelling the piston which allows the pressurized fluid or gas to enter the lower pressure space.

  9. Development of a control system for compression and expansion cycles of critical valve for high vacuum systems

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Jyoti, E-mail: jagarwal@ipr.res.in; Sharma, H.; Patel, Haresh; Gangradey, R.; Lambade, Vrushabh

    2016-11-15

    Highlights: • Control system with feedback loop of pressure gauge is developed for measuring the life cycle of vacuum isolation valve. • GUI based software developed for easy use and handling of control system. • Control system tested with an experiment showcasing the capability of the control system. • Control system can operate valve based on pressure inside the chamber, which helps to know the degradation of sealing capabilities of valve. • Control system can monitor the total closing and opening time of valve, cycles and pressure inside the vessel. - Abstract: A control system with feedback loop is designed, developed and tested to monitor the life cycles of the axial valve and bellows used in vacuum valves. The control system monitors number of compression cycles of any bellow or closing and opening cycle of a valve. It also interfaces vacuum gauges or pressure gauges to get pressure values inside the system. To find life cycle of valve, the developed control and monitoring system is integrated with an axial valve experimental test set up. In this system, feedback from the vacuum gauge attached to valve enclosure, is given and the life cycle test is automated. This paper describes the control and monitoring system in details and briefs the experiment carried out for valve life cycle. The same system can be used for life cycle estimate for bellows. A suitable GUI is also developed to control the function of the components and resister the number of cycles.

  10. Ethylene controlled ventilation. Energy conservation in the project 'Klep Dicht' (Close the Valve) and results of supplementary research; Ethyleengestuurde ventilatie. Energiebesparing in het project 'Klep Dicht' en resultaten van aanvullend onderzoek

    Energy Technology Data Exchange (ETDEWEB)

    Wildschut, J. [Praktijkonderzoek Plant en Omgeving PPO, Bloembollen, Boomkwekerij en Fruit, Lisse (Netherlands); Langner-Noort, L. [DLV Plant, Wageningen (Netherlands)

    2007-11-15

    The project ‘Close the Valve’ has been initiated with the aim of demonstrating the energy conservation options through ethylene-controlled ventilation of tulip flower bulb. During previous meetings on the ethylene analyzer, there were some urgent questions about practical use: What happens with the ethylene content during an Actellic treatment?; What is the influence of the ethylene content in outdoor air?; How is the ethylene distribution in the storage room?; The supplementary research involved the effect of ethylene in outdoor air, the distribution of ethylene in the cold store, and the behavior of ethylene during the period of the Actellic treatment (Actellic is an insecticide) [Dutch] Het project 'Klep Dicht' is opgezet met als doel de energiebesparingsmogelijkheden door ethyleengestuurde ventilatie van tulpenbollen te demonstreren. Tijdens eerdere bijeenkomsten over de ethyleenanalyser, kwamen een aantal dringende vragen uit de praktijk naar voren: Wat gebeurt er met het ethyleengehalte tijdens een Actellic-behandeling?; Hoe zit het met de invloed van het ethyleengehalte in de buitenlucht?; Hoe zit het met de ethyleenverdeling in de bewaarruimte? Het aanvullende onderzoek betrof het effect van ethyleen in de buitenlucht, de verdeling van het ethyleen in de bewaarcel, en het gedrag van ethyleen tijdens de periode van de actellicbehandeling (actellic is een insecticide)

  11. Patents and heart valve surgery--I: mechanical valves.

    Science.gov (United States)

    Cheema, Faisal H; Hussain, Nasir; Kossar, Alexander P; Polvani, Gianluca

    2013-04-01

    Valvular heart disease, inherited or acquired, affects more than 5 million Americans yearly. Whereas medical treatment is beneficial in the initial stages of valvular heart disease, surgical correction provides symptomatic relief and long-term survival benefits. Surgical options include either repair or replacement using mechanical or bio-prosthetic valves. Patient age and the post-operative need for anticoagulation therapy are major determinants of the choice between use of mechanical or bio-prosthetic valves. Since the first mechanical valves were made available several decades ago, the incorporation of increasingly sophisticated materials and methodologies has led to substantial improvements in the valve design, and has catalyzed a parallel increase in the amount of patents issued for these emerging technologies. In this paper, we have chronologically reviewed such patents, briefly discussed various challenges that mechanical heart valve implementation is faced with and finally reviewed some of the strategies employed to overcome such obstacles. An ideal prosthetic heart valve would comprehensively mimic the natural hemodynamics and physiology of the native heart valve. Additionally, such a valve would be easily implantable, associated with a minimal risk of thrombosis and thus need for anti-coagulation, and with a proven long-term durability. With cutting edge technological advancements in the recent times, the ongoing innovative and collaborative efforts of physicians, scientists, and engineers will not seize until an ideal mechanical heart valve becomes a reality.

  12. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    countries. METHODS: A multi-institutional, non-randomized, retrospective analysis was conducted among 2,932 patients who underwent AVR surgery at seven tertiary cardiac surgery centers throughout Europe. Demographic and perioperative variables including valve size and type, body surface area (BSA) and early...... and southern European countries. Imbalances in the prevalence of rheumatic heart disease, health resource availability and variations in surgical practice throughout Europe might be possible etiological causes....

  13. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  14. Optothermally actuated capillary burst valve

    Science.gov (United States)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders; Marie, Rodolphe

    2017-04-01

    We demonstrate the optothermal actuation of individual capillary burst valves in an all-polymer microfluidic device. The capillary burst valves are realised in a planar design by introducing a fluidic constriction in a microfluidic channel of constant depth. We show that a capillary burst valve can be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett. 10, 826-832 (2010)]. An individual valve is burst by focusing the laser in its vicinity. We demonstrate the capture of single polystyrene 7 μm beads in the constriction triggered by the bursting of the valve.

  15. Update of transcatheter valve treatment.

    Science.gov (United States)

    Liu, Xian-bao; Wang, Jian-an

    2013-08-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair--MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed.

  16. Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves

    Science.gov (United States)

    Ramaswamy, Sharan; Salinas, Manuel; Carrol, Rob; Landaburo, Karla; Ryans, Xavier; Crespo, Cynthia; Rivero, Ailyn; Al-Mousily, Faris; DeGroff, Curt; Bleiweis, Mark; Yamaguchi, Hitomi

    2013-01-01

    Limitations of currently available prosthetic valves, xenografts, and homografts have prompted a recent resurgence of developments in the area of tri-leaflet polymer valve prostheses. However, identification of a protocol for initial assessment of polymer valve hydrodynamic functionality is paramount during the early stages of the design process. Traditional in vitro pulse duplicator systems are not configured to accommodate flexible tri-leaflet materials; in addition, assessment of polymer valve functionality needs to be made in a relative context to native and prosthetic heart valves under identical test conditions so that variability in measurements from different instruments can be avoided. Accordingly, we conducted hydrodynamic assessment of i) native (n = 4, mean diameter, D = 20 mm), ii) bi-leaflet mechanical (n= 2, D = 23 mm) and iii) polymer valves (n = 5, D = 22 mm) via the use of a commercially available pulse duplicator system (ViVitro Labs Inc, Victoria, BC) that was modified to accommodate tri-leaflet valve geometries. Tri-leaflet silicone valves developed at the University of Florida comprised the polymer valve group. A mixture in the ratio of 35:65 glycerin to water was used to mimic blood physical properties. Instantaneous flow rate was measured at the interface of the left ventricle and aortic units while pressure was recorded at the ventricular and aortic positions. Bi-leaflet and native valve data from the literature was used to validate flow and pressure readings. The following hydrodynamic metrics were reported: forward flow pressure drop, aortic root mean square forward flow rate, aortic closing, leakage and regurgitant volume, transaortic closing, leakage, and total energy losses. Representative results indicated that hydrodynamic metrics from the three valve groups could be successfully obtained by incorporating a custom-built assembly into a commercially available pulse duplicator system and subsequently, objectively compared to provide

  17. Measurements of flow past a bileaflet mechanical heart valve

    Science.gov (United States)

    Haya, Laura; Tavoularis, Stavros

    2013-11-01

    A bileaflet mechanical heart valve has been inserted in an axisymmetric model of the aorta within a mock circulation apparatus with physiological pressure and flow variations. The velocity field behind the valve has been measured with laser Doppler velocimetry and particle image velocimetry. The results closely match those reported by similar studies. A triple jet emanated from the valve's orifices and regions of reverse flow formed in the sinus region. Velocity fluctuations were greatest in the shear layers of the jets. The average r.m.s. streamwise velocity fluctuation over the turbulent period was 0.22 m/s; its maximum value was 0.53 m/s and occurred at the onset of deceleration. Measurements with the valve inserted in an anatomical model of the aorta are planned for the near future. The present and future measurements will be compared to determine the effects of the aorta anatomy on the characteristics of flow through bileaflet valves. In particular, measurements of the viscous and turbulent shear stresses will be analyzed to identify possible locations of blood element damage, and regions of recirculation and stagnation will be identified as locations favourable to thrombus growth. The effects of flows in branching arteries and valve orientation will also be investigated. Supported by NSERC.

  18. Mitral valve repair versus replacement

    Science.gov (United States)

    Keshavamurthy, Suresh; Gillinov, A. Marc

    2015-01-01

    Degenerative, ischemic, rheumatic and infectious (endocarditis) processes are responsible for mitral valve disease in adults. Mitral valve repair has been widely regarded as the optimal surgical procedure to treat mitral valve dysfunction of all etiologies. The supporting evidence for repair over replacement is strongest in degenerative mitral regurgitation. The aim of the present review is to summarize the data in each category of mitral insufficiency and to provide recommendations based upon this data. PMID:26309824

  19. Vibrations of Damaged Functionally Graded Cantilever Beams

    Science.gov (United States)

    Byrd, Larry W.; Birman, Victor

    2008-02-01

    The paper discusses closed-form solutions of the problems of free and forced vibrations of a functionally graded cantilever FGM beam with and without damage. The mode of damage considered in the paper is represented by cracks that are perpendicular to the axis of the beam. Notably, such mode of damage was observed in experiments on representative FGM beams. Forced vibrations considered in the paper were generated by a kinematic excitation of the clamped end of the beam.

  20. Internal Acoustics of a Pintle Valve with Supercritical Helium Flow

    Science.gov (United States)

    Fishbach, Sean R.; Davis, R. Benjamin

    2010-01-01

    Large amplitude flow unsteadiness is a common phenomenon within the high flow rate ducts and valves associated with propulsion systems. Boundary layer noise, shear layers and vortex shedding are a few of the many sources of flow oscillations. The presence of lightly damped acoustic modes can organize and amplify these sources of flow perturbation, causing undesirable loading of internal parts. The present study investigates the self-induced acoustic environment within a pintle valve subject to high Reynolds Number flow of helium gas. Experiments were conducted to measure the internal pressure oscillations of the Ares I Launch Abort System (LAS) Attitude Control Motor (ACM) valve. The AGM consists of a solid propellant gas generator with eight pintle valves attached to the aft end. The pintle valve is designed to deliver variable upstream conditions to an attache( converging diverging nozzle. In order to investigate the full range of operating conditions 28 separate tests were conducted with varying pintle position and upstream pressure. Helium gas was utilized in order to closely mimic the speed of sound of the gas generator exhaust, minimizing required scaling during data analysis. The recordec pressure measurements were interrogated to multiple ends. The development of root mean square (RMS) value! versus Reynolds Number and Pintle position are important to creating bounding unsteady load curves for valve internal parts. Spectral analysis was also performed, helping to identify power spectral densities (PSD) of acoustic natural frequencies and boundary layer noise. An interesting and unexpected result was the identification of an acoustic mode within the valve which does not respond until the valve was over 60% open. Further, the response amplitude around this mode can be as large or larger than those associated with lower frequency modes.

  1. Self-actuated Polymeric Valve for Autonomous Sensing and Mixing

    DEFF Research Database (Denmark)

    Häfliger, Daniel; Marie, Rodolphe Charly Willy; Boisen, Anja

    2005-01-01

    the flapper in a flat, stress-balanced closed position. Upon contact with an analyte composed of a NaOH solution the Al film is etched from the valve surface unbalancing the surface stress and bending the flapper. A deflection of up to 45 μm is observed allowing for effective release of a green marker from...

  2. Design Optimization of Moving Magnet Actuated Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Madsen, Esben Lundø; Nørgård, Christian; Bech, Michael Møller

    2017-01-01

    optimized design closes in 2.1 ms, has a pressure drop of 0.8 bar at 150 l/min and yields a digital displacement machine average chamber efficiency of 98.9%. The design is simple in construction and uses a single coil, positioned outside the pressure chamber, eliminating the need for an electrical interface......High-efficiency hydraulic machines using digital valves are presently a topic of great focus. Digital valve performance with respect to pressure loss, closing time as well as electrical power consumption, is key to obtaining high efficiency. A recent digital seat valve design developed at Aalborg...

  3. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural...

  4. Effects of tilting disk heart valve gap width on regurgitant flow through an artificial heart mitral valve.

    Science.gov (United States)

    Maymir, J C; Deutsch, S; Meyer, R S; Geselowitz, D B; Tarbell, J M

    1997-09-01

    While many investigators have measured the turbulent stresses associated with forward flow through tilting disk heart valves, only recently has attention been given to the regurgitant jets formed as fluid is squeezed through the gap between the occluder and housing of a closed valve. The objective of this investigation was to determine the effect of gap width on the turbulent stresses of the regurgitant jets through a Björk-Shiley monostrut tilting disk heart valve seated in the mitral position of a Penn State artificial heart. A 2 component laser-Doppler velocimetry system with a temporal resolution of 1 ms was used to measure the instantaneous velocities in the regurgitant jets in the major and minor orifices around the mitral valve. The gap width was controlled through temperature variation by taking advantage of the large difference between the thermal expansion coefficients of the Delrin occluder and the Stellite housing of Björk-Shiley monostrut valves. The turbulent shear stress and mean (ensemble averaged) velocity were incorporated into a model of red blood cell damage to assess the potential for hemolytic damage at each gap width investigated. The results revealed that the minor orifice tends to form stronger jets during regurgitant flow than the major orifice, indicating that the gap width is not uniform around the circumference of the valve. Based on the results of a red blood cell damage model, the hemolytic potential of the mitral valve decreases as the gap width increases. This investigation also established that the hemolytic potential of the regurgitant phase of valve operation is comparable to, if not greater than, the hemolytic potential of forward flow, consistent with experimental data on hemolysis.

  5. Aircraft Anti-Skid Brake Control Based on High-Speed on-off Valve

    Directory of Open Access Journals (Sweden)

    Li Wei

    2015-01-01

    Full Text Available Aircraft hydraulic brake system usually use pressure servo valve for anti-skid brake control. As pressure servo valve realizes the pressure closed loop by hydraulic feedback loop, this structure increased the complexity of the processing and manufacturing, restricted the pressure closed loop parameters adjustment, and increased the difficulty of debugging the system design. Pressure servo valve is expensive and difficult to process, poor ability to resist pollution. This paper proposed a slip ratio large closed loop aircraft anti-skid brake control method based on high-speed on-off valve, built the model of aircraft ground vertical taxiing and slip ratio large closed loop control algorithm in the MATLAB/SIMULINK, and built the model of aircraft hydraulic brake system based on on-off valve in the AMESim and a joint simulation was carried out. The simulation results show that the aircraft anti-skid brake control method based on high-speed on-off valve is feasible, and the on-off valve is cheap with strong ability to resist pollution, easy processing and manufacturing and so on, showing a good application prospect.

  6. In vitro evaluation of implantation depth in valve-in-valve using different transcatheter heart valves.

    Science.gov (United States)

    Simonato, Matheus; Azadani, Ali N; Webb, John; Leipsic, Jonathon; Kornowski, Ran; Vahanian, Alec; Wood, David; Piazza, Nicolo; Kodali, Susheel; Ye, Jian; Whisenant, Brian; Gaia, Diego; Aziz, Mina; Pasala, Tilak; Mehilli, Julinda; Wijeysundera, Harindra C; Tchetche, Didier; Moat, Neil; Teles, Rui; Petronio, Anna Sonia; Hildick-Smith, David; Landes, Uri; Windecker, Stephan; Arbel, Yaron; Mendiz, Oscar; Makkar, Raj; Tseng, Elaine; Dvir, Danny

    2016-09-18

    Transcatheter heart valve (THV) implantation in failed bioprosthetic valves (valve-in-valve [ViV]) offers an alternative therapy for high-risk patients. Elevated post-procedural gradients are a significant limitation of aortic ViV. Our objective was to assess the relationship between depth of implantation and haemodynamics. Commercially available THVs used for ViV were included in the analysis (CoreValve Evolut, SAPIEN XT and the Portico valve). THVs were implanted in small surgical valves (label size 19 mm) to simulate boundary conditions. Custom-mounted pulse duplicators registered relevant haemodynamic parameters. Twenty-eight experiments were performed (13 CVE, 5 SXT and 10 Portico). Ranges of depth of implantation were: CVE: -1.2 mm to 15.7 mm; SXT: -2.2 mm to 7.5 mm; Portico: 1.4 mm to 12.1 mm. Polynomial regression established a relationship between depth of implantation and valvular mean gradients (CVE: p<0.001; SXT: p=0.01; Portico: p=0.002), as well as with EOA (CVE: p<0.001; SXT: p=0.02; Portico valve: p=0.003). In addition, leaflet coaptation was better in the high implantation experiments for all valves. The current comprehensive bench testing assessment demonstrates the importance of high device position for the attainment of optimal haemodynamics during aortic ViV procedures.

  7. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  8. Fault detection in reciprocating compressor valves under varying load conditions

    Science.gov (United States)

    Pichler, Kurt; Lughofer, Edwin; Pichler, Markus; Buchegger, Thomas; Klement, Erich Peter; Huschenbett, Matthias

    2016-03-01

    This paper presents a novel approach for detecting cracked or broken reciprocating compressor valves under varying load conditions. The main idea is that the time frequency representation of vibration measurement data will show typical patterns depending on the fault state. The problem is to detect these patterns reliably. For the detection task, we make a detour via the two dimensional autocorrelation. The autocorrelation emphasizes the patterns and reduces noise effects. This makes it easier to define appropriate features. After feature extraction, classification is done using logistic regression and support vector machines. The method's performance is validated by analyzing real world measurement data. The results will show a very high detection accuracy while keeping the false alarm rates at a very low level for different compressor loads, thus achieving a load-independent method. The proposed approach is, to our best knowledge, the first automated method for reciprocating compressor valve fault detection that can handle varying load conditions.

  9. Investigation of a rotary valving system with variable valve timing for internal combustion engines: Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Cross, P.C.; Hansen, C.N.

    1994-11-18

    The objective of the program was to provide a functional demonstration of the Hansen Rotary Valving System with Variable Valve timing (HRVS/VVT), capable of throttleless inlet charge control, as an alternative to conventional poppet-valves for use in spark ignited internal combustion engines. The goal of this new technology is to secure benefits in fuel economy, broadened torque band, vibration reduction, and overhaul accessibility. Additionally, use of the variable valve timing capability to vary the effective compression ratio is expected to improve multi-fuel tolerance and efficiency. Efforts directed at the design of HRVS components proved to be far more extensive than had been anticipated, ultimately requiring that proof-trial design/development work be performed. Although both time and funds were exhausted before optical or ion-probe types of in-cylinder investigation could be undertaken, a great deal of laboratory data was acquired during the course of the design/development work. This laboratory data is the basis for the information presented in this Final Report.

  10. [Heart valve prosthesis and pregnancy].

    Science.gov (United States)

    Ben-Ismail, M; Fekih, M; Taktak, M; Chelli, M

    1979-02-01

    Sixteen pregnancies were followed up in 13 patients with prosthetic heart valves: 8 pregnancies went to term under oral anticoagulation, 4 under heparin and 4 without anticoagulation. 9 healthy normal children were delivered; there were 2 still births and 5 abortions. On the maternal side 3 haemorrhages and thromboembolic episodes which involved 2 patients on heparin, one of whom died, were observed. The following points are apparent from our observations and a review of the existing medical literature: --the risk of thromboembolism is not increased. The marked clotting tendency of maternal blood post-partum contraindicates the withdrawal of anticoagulants during this critical period; --haemorrhagic complications are common with anticoagulants; --foetal loss is greatly increased; --the teratogenecity of vitamin-K antagonists is certain, but the risk is small. The problems of anticoagulation are discussed; theoretically heparin should be given during the 1st trimestre and from the 38th week to the second post-partum week. The patients should be closely supervised by both obstetrician and cardiologist and hospitalisation is advised for the last month of pregnancy. Normal vaginal delivery is usually possible.

  11. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...

  12. The spin-valve transistor

    NARCIS (Netherlands)

    Anil Kumar, P.S.; Lodder, J.C.

    2000-01-01

    The spin-valve transistor is a magnetoelectronic device that can be used as a magnetic field sensor. It has a ferromagnet-semiconductor hybrid structure. Using a vacuum metal bonding technique, the spin-valve transistor structure Si/Pt/NiFe/Au/Co/Au/Si is obtained. It employs hot electron transport

  13. Mechanical Valve Replacement: Early Results

    Directory of Open Access Journals (Sweden)

    Habib Cakir

    2012-03-01

    Conclusion: Mechanical prosthetic valves are used for surgical treatment of valve disease with low mortality and morbidity in a large group of patients like women that not to think to get pregnant, non advanced age group and patients have less risky for anticoagulation drug in our clinic. [Cukurova Med J 2012; 37(1: 49-54

  14. Control of the valve system of multicyclic bed testers

    Energy Technology Data Exchange (ETDEWEB)

    Lopatkin, O.P.; Varlamov, P.S.

    1980-01-01

    It has been established that in testing beds with the help of multicyclic testers in twisted wells, the height of lifting the pipes for closure of the valve should be determined with regard for the resistance forces during movement of the drilling pipe string. A plan is presented for the pipe shaft with lowered drilling string after installation of the packer. The technique developed in the North Caucasus Scientific Research and Planning Institute of the Oil Industry will make it possible to determine for deep twisted wells the height of lifting of the string drilling pipes needed to close the safety valve of the multicyclic bed tester.

  15. Numerical simulation on a throttle governing system with hydraulic butterfly valves in a marine environment

    Science.gov (United States)

    Wan, Hui-Xiong; Fang, Jun; Huang, Hui

    2010-12-01

    Hydraulic butterfly valves have been widely applied in marine engineering because of their large switching torque, low pressure loss and suitability for large and medium diameter pipelines. Due to control problems resulting from switching angular speeds of the hydraulic butterfly valve, a throttle-governing control mode has been widely adopted, and detailed analysis has been carried out worldwide on the structural principle concerning speed-regulation and the load torque on the shaft while opening or closing a hydraulic butterfly valve. However relevant reports have yet been published on the change law, the error and the influencing factors of the rotational angular velocity of the hydraulic butterfly valve while opening and closing. In this article, research was based on some common specifications of a hydraulic butterfly valve with a symmetrical valve flap existing in a marine environment. The throttle governing system supplied by the accumulator to achieve the switching of the hydraulic control valve was adopted, and the mathematical models of the system were established in the actual conditions while the numerical simulations took place. The simulation results and analysis show that the rotational angular velocity and the error of the hydraulic butterfly valve while switching is influenced greatly by the drainage amount of the accumulator, resulting in pressure loss in the pipeline, the temperature of hydraulic medium and the load of the hydraulic butterfly valve. The simulation results and analysis provide a theoretical basis for the choice of the total capacity of the accumulator and pipeline diameters in a throttle governing system with a hydraulic butterfly valve. It also determines the type and specification of the hydraulic butterfly valve and the design of motion parameters of the transported fluid.

  16. High-speed imaging of developing heart valves reveals interplay of morphogenesis and function.

    Science.gov (United States)

    Scherz, Paul J; Huisken, Jan; Sahai-Hernandez, Pankaj; Stainier, Didier Y R

    2008-03-01

    Knowing how mutations disrupt the interplay between atrioventricular valve (AVV) morphogenesis and function is crucial for understanding how congenital valve defects arise. Here, we use high-speed fluorescence microscopy to investigate AVV morphogenesis in zebrafish at cellular resolution. We find that valve leaflets form directly through a process of invagination, rather than first forming endocardial cushions. There are three phases of valve function in embryonic development. First, the atrioventricular canal (AVC) is closed by the mechanical action of the myocardium, rolls together and then relaxes. The growing valve leaflets serve to block the canal during the roll and, depending on the developmental stage, either expand or hang down as a leaflet to block the canal. These steps are disrupted by the subtle morphological changes that result from inhibiting ErbB-, TGFbeta-or Cox2 (Ptgs2)-dependent signaling. Cox2 inhibition affects valve development due to its effect on myocardial cell size and shape, which changes the morphology of the ventricle and alters valve geometry. Thus, different signaling pathways regulate distinct aspects of the behavior of individual cells during valve morphogenesis, thereby influencing specific facets of valve function.

  17. FAILURE MODE AND EFFECT ANALYSIS (FMEA OF BUTTERFLY VALVE IN OIL AND GAS INDUSTRY

    Directory of Open Access Journals (Sweden)

    MUHAMMAD AMIRUL BIN YUSOF

    2016-04-01

    Full Text Available Butterfly valves are mostly used in various industries such as oil and gas plant. This valve operates with rotating motion using pneumatic system. Rotating actuator turns the disc either parallel or perpendicular to the flow. When the valve is fully open, the disc is rotated a quarter turn so that it allows free passage of the fluid and when fully closed, the disc rotated a quarter turns to block the fluid. The primary failure modes for valves are the valve leaks to environment through flanges, seals on the valve body, valve stem packing not properly protected, over tightened packing nuts, the valve cracks and leaks over the seat. To identify the failure of valve Failure Mode and Effects Analysis has been chosen. FMEA is the one of technique to perform failure analysis. It involves reviewing as many components to identify failure modes, and their causes and effects. For each component, the failure modes and their resulting effects on the rest of the system are recorded in a specific FMEA form. Risk priority number, severity, detection, occurrence are the factor determined in this studies. Risk priority number helps to find out the highest hazardous activities which need more attention than the other activity. The highest score of risk priority number in this research is seat. Action plan was proposed to reduce the risk priority number and so that potential failures also will be reduced.

  18. Overview of Prevention for Water Hammer by Check Valve Action in Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Water hammer can cause serious damage to pumping system and unexpected system pressure rise in the pipeline. In nuclear reactor, water hammer can influence on the integrity of safety related system. Water hammer in nuclear reactor have been caused by voiding in normally water-filled lines, steam condensation line containing both steam and water, as well as by rapid check valve action. Therefore, this study focuses on the water hammer by check valve among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. This study focuses on the water hammer by check valve action among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. If the inadvertent pump trip or pipe rupture in high velocity and pressure pipe is predicted, the fast response check valve such as tiled disc, dual disc and nozzle check valve should be installed in the system. If the inadvertent pump trip or pipe rupture in very high velocity and pressure pipe and excessively large revered flow velocity are predicted, the very slowly closing check valve such as controlled closure check valve should be installed in the system.

  19. Tunable Passive Vibration Suppressor

    Science.gov (United States)

    Boechler, Nicholas (Inventor); Dillon, Robert Peter (Inventor); Daraio, Chiara (Inventor); Davis, Gregory L. (Inventor); Shapiro, Andrew A. (Inventor); Borgonia, John Paul C. (Inventor); Kahn, Daniel Louis (Inventor)

    2016-01-01

    An apparatus and method for vibration suppression using a granular particle chain. The granular particle chain is statically compressed and the end particles of the chain are attached to a payload and vibration source. The properties of the granular particles along with the amount of static compression are chosen to provide desired filtering of vibrations.

  20. Vibrations and Eigenvalues

    Indian Academy of Sciences (India)

    We make music by causing strings, membranes, or air columns to vibrate. Engineers design safe structures by control- ling vibrations. I will describe to you a very simple vibrating system and the mathematics needed to analyse it. The ideas were born in the work of Joseph-Louis Lagrange (1736–1813), and I begin by quot-.

  1. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    Science.gov (United States)

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. A novel magnetic valve using room temperature magnetocaloric materials

    DEFF Research Database (Denmark)

    Eriksen, Dan; Bahl, Christian; Pryds, Nini

    2012-01-01

    Magnetocaloric materials with near-room-temperature tuneable Curie temperatures have been utilized to develop a novel magnetic valve technology. The temperature dependent attractive force between the materials and a permanent magnet assembly is used to actuate valves as a response to temperature...... changes. This is made possible by the strong temperature dependence of the magnetization close to the Curie temperature of the magnetocaloric materials. Different compositions of both La0.67(Ca,Sr)0.33MnO3 and La(Fe,Co,Si)13 have been considered for use in prototype valves. Based on measured magnetization...... data a 3D finite element model has been set up to calculate the magnetic force between (graded) blocks of these materials and a permanent magnet assembly. The results have been used to calculate equilibrium points for actuation systems where the magnetic force is balanced by a spring force...

  3. Anatomic, histopathologic, and echocardiographic features in a dog with an atypical pulmonary valve stenosis with a fibrous band of tissue and a patent ductus arteriosus.

    Science.gov (United States)

    Yoon, Hakyoung; Kim, Jaehwan; Nahm, Sang-Soep; Eom, Kidong

    2017-07-11

    Congenital pulmonary valve stenosis and patent ductus arteriosus are common congenital heart defects in dogs. However, concurrence of atypical pulmonary valve stenosis and patent ductus arteriosus is uncommon. This report describes the anatomic, histopathologic, and echocardiographic features in a dog with concomitant pulmonary valve stenosis and patent ductus arteriosus with atypical pulmonary valve dysplasia that included a fibrous band of tissue. A 1.5-year-old intact female Chihuahua dog weighing 3.3 kg presented with a continuous grade VI cardiac murmur, poor exercise tolerance, and an intermittent cough. Echocardiography indicated pulmonary valve stenosis, a thickened dysplastic valve without annular hypoplasia, and a type IIA patent ductus arteriosus. The pulmonary valve was thick line-shaped in systole and dome-shaped towards the right ventricular outflow tract in diastole. The dog suffered a fatal cardiac arrest during an attempted balloon pulmonary valvuloplasty. Necropsy revealed pulmonary valve dysplasia, commissural fusion, and incomplete opening and closing of the pulmonary valve because of a fibrous band of tissue causing adhesion between the right ventricular outflow tract and the dysplastic intermediate cusp of the valve. A fibrous band of tissue between the right ventricular outflow track and the pulmonary valve should be considered as a cause of pulmonary valve stenosis. Pulmonary valve stenosis and patent ductus arteriosus can have conflicting effects on diastolic and systolic dysfunction, respectively. Therefore, beta-blockers should always be used carefully, particularly in patients with a heart defect where there is concern about left ventricular systolic function.

  4. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  5. Piezoelectric energy harvesting from broadband random vibrations

    Science.gov (United States)

    Adhikari, S.; Friswell, M. I.; Inman, D. J.

    2009-11-01

    Energy harvesting for the purpose of powering low power electronic sensor systems has received explosive attention in the last few years. Most works using deterministic approaches focusing on using the piezoelectric effect to harvest ambient vibration energy have concentrated on cantilever beams at resonance using harmonic excitation. Here, using a stochastic approach, we focus on using a stack configuration and harvesting broadband vibration energy, a more practically available ambient source. It is assumed that the ambient base excitation is stationary Gaussian white noise, which has a constant power-spectral density across the frequency range considered. The mean power acquired from a piezoelectric vibration-based energy harvester subjected to random base excitation is derived using the theory of random vibrations. Two cases, namely the harvesting circuit with and without an inductor, have been considered. Exact closed-form expressions involving non-dimensional parameters of the electromechanical system have been given and illustrated using numerical examples.

  6. Prediction Models of Free-Field Vibrations from Railway Traffic

    DEFF Research Database (Denmark)

    Malmborg, Jens; Persson, Kent; Persson, Peter

    2017-01-01

    and railways close to where people work and live. Annoyance from traffic-induced vibrations and noise is expected to be a growing issue. To predict the level of vibration and noise in buildings caused by railway and road traffic, calculation models are needed. In the present paper, a simplified prediction...

  7. A study on the evaluation of vibration effect and the development of vibration reduction method for Wolsung unit 1 main steam piping

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun; Kim, Yeon Whan [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center; Kim, Tae Ryong; Park, Jin Ho [Korea Atomic Energy Research Inst., Daeduk (Korea, Republic of)

    1996-08-01

    The main steam piping of nuclear power plant which runs between steam generator and high pressure turbine has been experienced to have a severe effect on the safe operation of the plant due to the vibration induced by the steam flowing inside the piping. The imposed cyclic loads by the vibration could result in the degradation of the related structures such as connection parts between main instruments, valves, pipe supports and building. The objective of the study is to reduce the vibration level of Wolsung nuclear power plant unit 1 main steam pipeline by analyzing vibration characteristics of the piping, identifying sources of the vibration and developing a vibration reduction method .The location of the maximum vibration is piping between the main steam header and steam chest .The stress level was found to be within the allowable limit .The main vibration frequency was found to be 4{approx}6 Hz which is the same as the natural frequency from model test .A vibration reduction method using pipe supports of energy absorbing type(WEAR)is selected .The measured vibration level after WEAR installation was reduced about 36{approx}77% in displacement unit (author). 36 refs., 188 figs.

  8. Broadband vibration energy harvester utilizing three out-of-plane modes of one vibrating body

    Science.gov (United States)

    Park, Shi-Baek; Jang, Seon-Jun; Kim, In-Ho; Choi, Yong Je

    2017-10-01

    In this paper, we introduce the concept, design equation, and realization of a broadband electromagnetic vibrational energy harvester. The spatial vibrating system in the proposed harvester is arranged to have three out-of-plane vibration modes. We devise the design method for its three natural frequencies and accompanying modes and apply it to the broadband energy harvesting by locating three frequencies close to each other. The numerical simulation and the experimental results show that it satisfies the designated frequencies as well as the enhanced bandwidth for power generation.

  9. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  10. Determination of optimal whole body vibration amplitude and frequency parameters with plyometric exercise and its influence on closed-chain lower extremity acute power output and EMG activity in resistance trained males

    Science.gov (United States)

    Hughes, Nikki J.

    The optimal combination of Whole body vibration (WBV) amplitude and frequency has not been established. Purpose. To determine optimal combination of WBV amplitude and frequency that will enhance acute mean and peak power (MP and PP) output EMG activity in the lower extremity muscles. Methods. Resistance trained males (n = 13) completed the following testing sessions: On day 1, power spectrum testing of bilateral leg press (BLP) movement was performed on the OMNI. Days 2 and 3 consisted of WBV testing with either average (5.8 mm) or high (9.8 mm) amplitude combined with either 0 (sham control), 10, 20, 30, 40 and 50 Hz frequency. Bipolar surface electrodes were placed on the rectus femoris (RF), vastus lateralis (VL), bicep femoris (BF) and gastrocnemius (GA) muscles for EMG analysis. MP and PP output and EMG activity of the lower extremity were assessed pre-, post-WBV treatments and after sham-controls on the OMNI while participants performed one set of five repetitions of BLP at the optimal resistance determined on Day 1. Results. No significant differences were found between pre- and sham-control on MP and PP output and on EMG activity in RF, VL, BF and GA. Completely randomized one-way ANOVA with repeated measures demonstrated no significant interaction of WBV amplitude and frequency on MP and PP output and peak and mean EMGrms amplitude and EMG rms area under the curve. RF and VL EMGrms area under the curve significantly decreased (p power output.

  11. Considerations Regarding the Stresses and the Deformations of the Butterfly Valve Body

    Directory of Open Access Journals (Sweden)

    Florin Peris-Bendu

    2013-09-01

    Full Text Available In the present paper it is analyzed the “von Mises” equivalent stress distribution, respectively strains, which appear in the body of a butterfly valve with nominal diameter (DN of 2800 mm and operates at a nominal pressure (PN 19 bar. The paper examines the body of a butterfly valve using finite element method and the followings data is considered to be known: boundary conditions for which the analysis is made in both positions, the valve disk in the closed position and the open position, mechanical characteristics and resistance of the materials for valve body components and loads to which it is subject. The result of the analysis obtained allow optimization of the valve body size by highlighting the oversized areas respectively areas where efforts are maximized.

  12. Analysis of in-line check valve with respect to the pipeline dynamics

    Directory of Open Access Journals (Sweden)

    Klas Roman

    2017-01-01

    Full Text Available The following study is focused on the flow analysis within the concentric in-line check valve. In-line check valve is part of the pipe and shut off the stream of fluid. In case that backflow occurs on the downstream side, the valve is fully or partially lifted and then abruptly closes. This effect brings undesirable pressure shocks in the entire system. The study therefore deals with the CFD analysis of steady and unsteady flow with respect to velocity and pressure field. Especially unsteady calculation mode reflects the influence of local inertial acceleration acting on the fluid and on the valve. Analysis is complemented by equation of motion of a valve which interacts with the fluid.

  13. Test of a Novel Moving Magnet Actuated Seat Valve for Digital Displacement Fluid Power Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Madsen, Esben Lundø; Christensen, Jeppe Haals

    2018-01-01

    electronicallycontrolled moving magnet actuated (MMA) annular seat valve is proposed, designed, built, and tested rigorously in the laboratory. The actuator is energized using one coil only, it has bidirectional force capability and it utilizes magnetic latching to keep it open instead of a spring. The annular seat valve...... has two metering edges; the static pressure drop is 0.11/0.31 bar at -142/108 l/min, respectively. The valve closing time is 4-6 ms depending on the flow rate. The MMA valve is tested experimentally in both standalone test rigs besides in situ tests in a fully operational digital displacement proto...... type machine. Measurements provided for pumping and motoring operation at 800 RPM/100 bar demonstrate that the proposed MMA valve topology is a promising candidate for energy-efficient digital displacement machines. Key characteristics include little power consumption, good switching performance...

  14. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  15. Vibration analysis of cryocoolers

    Science.gov (United States)

    Tomaru, Takayuki; Suzuki, Toshikazu; Haruyama, Tomiyoshi; Shintomi, Takakazu; Yamamoto, Akira; Koyama, Tomohiro; Li, Rui

    2004-05-01

    The vibrations of Gifford-McMahon (GM) and pulse-tube (PT) cryocoolers were measured and analyzed. The vibrations of the cold-stage and cold-head were measured separately to investigate their vibration mechanisms. The measurements were performed while maintaining the thermal conditions of the cryocoolers at a steady state. We found that the vibration of the cold-head for the 4 K PT cryocooler was two orders of magnitude smaller than that of the 4 K GM cryocooler. On the other hand, the vibration of the cold-stages for both cryocoolers was of the same order of magnitude. From a spectral analysis of the vibrations and a simulation, we concluded that the vibration of the cold-stage is caused by an elastic deformation of the pulse tubes (or cylinders) due to the pressure oscillation of the working gas.

  16. Vibration analysis of cryocoolers

    Energy Technology Data Exchange (ETDEWEB)

    Tomaru, Takayuki; Suzuki, Toshikazu; Haruyama, Tomiyoshi; Shintomi, Takakazu; Yamamoto, Akira [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki (Japan); Koyama, Tomohiro; Rui Li [Sumitomo Heavy Industries Ltd., Tokyo (Japan)

    2004-05-01

    The vibrations of Gifford-McMahon (GM) and pulse-tube (PT) cryocoolers were measured and analyzed. The vibrations of the cold-stage and cold-head were measured separately to investigate their vibration mechanisms. The measurements were performed while maintaining the thermal conditions of the cryocoolers at a steady state. We found that the vibration of the cold-head for the 4 K PT cryocooler was two orders of magnitude smaller than that of the 4 K GM cryocooler. On the other hand, the vibration of the cold-stages for both cryocoolers was of the same order of magnitude. From a spectral analysis of the vibrations and a simulation, we concluded that the vibration of the cold-stage is caused by an elastic deformation of the pulse tubes (or cylinders) due to the pressure oscillation of the working gas. (Author)

  17. Vibration of hydraulic machinery

    CERN Document Server

    Wu, Yulin; Liu, Shuhong; Dou, Hua-Shu; Qian, Zhongdong

    2013-01-01

    Vibration of Hydraulic Machinery deals with the vibration problem which has significant influence on the safety and reliable operation of hydraulic machinery. It provides new achievements and the latest developments in these areas, even in the basic areas of this subject. The present book covers the fundamentals of mechanical vibration and rotordynamics as well as their main numerical models and analysis methods for the vibration prediction. The mechanical and hydraulic excitations to the vibration are analyzed, and the pressure fluctuations induced by the unsteady turbulent flow is predicted in order to obtain the unsteady loads. This book also discusses the loads, constraint conditions and the elastic and damping characters of the mechanical system, the structure dynamic analysis, the rotor dynamic analysis and the system instability of hydraulic machines, including the illustration of monitoring system for the instability and the vibration in hydraulic units. All the problems are necessary for vibration pr...

  18. Management of a locked Strata valve.

    Science.gov (United States)

    Bullivant, Kelly J; Mitha, Alim P; Hamilton, Mark G

    2009-04-01

    The PS Medical Strata valve is a programmable shunt valve used in the treatment of hydrocephalus that allows for noninvasive changes in the pressure setting using a magnet. The Strata valve is sensitive to magnetic fields, and reprogramming is frequently necessary after MR imaging. A known but rare complication of the Strata valve is that the rotor can become locked, causing shunt malfunction. This complication can only occur in a first generation Strata valve.

  19. 3D Printed Multimaterial Microfluidic Valve

    OpenAIRE

    Keating, Steven J.; Gariboldi, Maria Isabella; Patrick, William G.; Sharma, Sunanda; Kong, David S.; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deform...

  20. Treatment of Aortic, Mitral and Tricuspid Structural Bioprosthetic Valve Deterioration Using the Valve-in-Valve Technique.

    Science.gov (United States)

    Codner, Pablo; Assali, Abid; Vaknin-Assa, Hana; Shapira, Yaron; Orvin, Katia; Sharony, Ram; Sagie, Alexander; Kornowski, Ran

    2015-05-01

    The percutaneous approach for a failed bioprosthetic valve is an emerging alternative to redo-valve surgery in patients at high surgical risk. The study aim was to describe the treatment of patients with structural bioprosthetic valve deterioration, using the valve-in-valve technique. A total of 33 consecutive patients with symptomatic structural bioprosthetic valve deterioration was treated at the authors' institution, using the valve-in-valve technique. The valve-in-valve procedure in the aortic position was performed in 23 patients (mean age 81.4 ± 5.9 years; mean STS score 9.6 ± 5.4). The self-expandable and balloon-expandable devices were used in 21 cases (91.3%) and two cases (8.7%), respectively. Procedures were performed via the trans-femoral, trans-axillary and trans-apical routes in 18 (78.2%), three (13%) and two (8.7%) cases, respectively. After the procedure, all patients were in NYHA class I/II. Survival rates were 95.6% at the one-year follow up. The valve-in-valve procedure in the mitral position was performed in 10 patients (mean age 73.6 ± 15 years; mean STS score 7.7 ± 4.1). All procedures were performed using the balloon-expandable device via the trans-apical route. The composite end point of device success was achieved in all patients. Survival rates were 100% and 75% at one month and two years' follow up, respectively. A single valve-in-valve implantation within a failed tricuspid bioprosthetic valve was also successfully performed. In the authors' experience, the valve-in-valve technique for the treatment of a wide range of bioprosthetic valve deterioration modes of failure in different valve positions is safe and very effective.

  1. Effects on fatigue life of gate valves due to higher torque switch settings during operability testing

    Energy Technology Data Exchange (ETDEWEB)

    Richins, W.D.; Snow, S.D.; Miller, G.K.; Russell, M.J.; Ware, A.G.

    1995-12-01

    Some motor operated valves now have higher torque switch settings due to regulatory requirements to ensure valve operability with appropriate margins at design basis conditions. Verifying operability with these settings imposes higher stem loads during periodic inservice testing. These higher test loads increase stresses in the various valve internal parts which may in turn increase the fatigue usage factors. This increased fatigue is judged to be a concern primarily in the valve disks, seats, yokes, stems, and stem nuts. Although the motor operators may also have significantly increased loading, they are being evaluated by the manufacturers and are beyond the scope of this study. Two gate valves representative of both relatively weak and strong valves commonly used in commercial nuclear applications were selected for fatigue analyses. Detailed dimensional and test data were available for both valves from previous studies at the Idaho National Engineering Laboratory. Finite element models were developed to estimate maximum stresses in the internal parts of the valves and to identity the critical areas within the valves where fatigue may be a concern. Loads were estimated using industry standard equations for calculating torque switch settings prior and subsequent to the testing requirements of USNRC Generic Letter 89--10. Test data were used to determine both; (1) the overshoot load between torque switch trip and final seating of the disk during valve closing and (2) the stem thrust required to open the valves. The ranges of peak stresses thus determined were then used to estimate the increase in the fatigue usage factors due to the higher stem thrust loads. The usages that would be accumulated by 100 base cycles plus one or eight test cycles per year over 40 and 60 years of operation were calculated.

  2. Integration of valving and sensing on a capillary-assembled microchip.

    Science.gov (United States)

    Hisamoto, Hideaki; Funano, Shun-ichi; Terabe, Shigeru

    2005-04-01

    A simple integration of both flow control valves and a reaction-based sensing function on a single microchip was performed by using capillary-assembled microchip (CAs-CHIP: Hisamoto, H.; Nakashima, Y.; Kitamura, C.; Funano, S.-i.; Yasuoka, M.; Morishima, K.; Kikutani, Y.; Kitamori, T.; Terabe, S. Anal. Chem. 2004, 76, 3222-3228.). In contrast to the previously reported on-chip valving systems, where the simple valving functions were integrated, our system can integrate not only valving function but also many other chemical functions to perform a complex chemical operation on a single microchip. Here, an enzymatic reaction-based readout system is employed as an example. A square capillary immobilizing N-isopropylacrylamide polymer monolith (referred to as "valving capillary") is used as a thermoresponsive "valving part" and the immobilizing enzyme-modified glycidyl methacrylate polymer monolith (referred to as "sensing capillary") is used as a "sensing part" of the CAs-CHIP. These capillaries are embedded into a lattice microchannel network fabricated on poly(dimethylsiloxane), which has the same channel dimensions as the outer dimensions of the square capillaries. After bonding, a small Peltier device (2 mm x 2 mm) for temperature control is placed on the embedded valving capillaries to control fluid flow. Using this for heating or cooling, fast operation times of 1.4 and 3.2 s for opening and closing valves, respectively, are successfully achieved. Finally, two valving capillaries are independently controlled to trap sample solution within a bypass channel, where the enzyme-immobilized capillary is embedded, and then enzymatic reaction-based sensing of chemical species is performed as an example. The fundamental characteristics of the valve-integrated microchip are fully investigated, and an application to the analysis of an enzyme substrate by using two independent valving capillaries and a sensing capillary is demonstrated.

  3. Downhole Vibration Monitoring and Control System

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2007-09-30

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. The key feature of this system is its use of a magnetorheological fluid (MRF) to allow the damping coefficient to be changed extensively, rapidly and reversibly without the use of mechanical valves, but only by the application of a current. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. Much of the effort was devoted to the design and testing of the MRF damper, itself. The principal objectives of Phase II were: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in a drilling laboratory. Phase II concluded on January 31, 2006, and a final report was issued. Work on Phase III of the project began during the first quarter, 2006, with the objectives of building precommercial prototypes, testing them in a drilling laboratory and the field; developing and implementing a commercialization plan. All of these have been accomplished. The Downhole Vibration Monitoring & Control System (DVMCS) prototypes have been successfully proven in testing at the TerraTek drilling facility and at the Rocky Mountain Oilfield Test Center (RMOTC.) Based on the results of these tests, we have signed a definitive development and distribution agreement with Smith, and commercial deployment is underway. This current version of the DVMCS monitors and controls axial vibrations. Due to time and budget constraints of this program, it was not possible to complete a system that would also deal with lateral and torsional (stick-slip) vibrations as originally planned; however, this effort is continuing without DOE

  4. Ultrasound based mitral valve annulus tracking for off-pump beating heart mitral valve repair

    Science.gov (United States)

    Li, Feng P.; Rajchl, Martin; Moore, John; Peters, Terry M.

    2014-03-01

    Mitral regurgitation (MR) occurs when the mitral valve cannot close properly during systole. The NeoChordtool aims to repair MR by implanting artificial chordae tendineae on flail leaflets inside the beating heart, without a cardiopulmonary bypass. Image guidance is crucial for such a procedure due to the lack of direct vision of the targets or instruments. While this procedure is currently guided solely by transesophageal echocardiography (TEE), our previous work has demonstrated that guidance safety and efficiency can be significantly improved by employing augmented virtuality to provide virtual presentation of mitral valve annulus (MVA) and tools integrated with real time ultrasound image data. However, real-time mitral annulus tracking remains a challenge. In this paper, we describe an image-based approach to rapidly track MVA points on 2D/biplane TEE images. This approach is composed of two components: an image-based phasing component identifying images at optimal cardiac phases for tracking, and a registration component updating the coordinates of MVA points. Preliminary validation has been performed on porcine data with an average difference between manually and automatically identified MVA points of 2.5mm. Using a parallelized implementation, this approach is able to track the mitral valve at up to 10 images per second.

  5. Phase diagram of vertically vibrated dense suspensions

    NARCIS (Netherlands)

    von Kann, S.; Snoeijer, Jacobus Hendrikus; van der Meer, Roger M.

    2014-01-01

    When a hole is created in a layer of a dense, vertically vibrated suspension, phenomena are known to occur that defy the natural tendency of gravity to close the hole. Here, an overview is presented of the different patterns that we observed in a variety of dense particulate suspensions.

  6. Probability of Failure in Random Vibration

    DEFF Research Database (Denmark)

    Nielsen, Søren R.K.; Sørensen, John Dalsgaard

    1988-01-01

    Close approximations to the first-passage probability of failure in random vibration can be obtained by integral equation methods. A simple relation exists between the first-passage probability density function and the distribution function for the time interval spent below a barrier before out...

  7. A giant myxoma originating from the aortic valve causing severe left ventricular tract obstruction: a case report and literature review.

    Science.gov (United States)

    Prifti, Edvin; Ademaj, Fadil; Kajo, Efrosina; Baboci, Arben

    2015-04-16

    The left ventricular localization of a myxoma is very rare, usually arising from the interventricular septum close to the left ventricular outflow tract, the mitral valve, the ventricular wall and extremely rarely the aortic valve. A 13-year-old male was admitted due to dyspnea and angina. Transesophageal echocardiography revealed left ventricular outflow tract obstruction with a mean gradient of 58 mmHg, and a mobile mass measuring 65×25 mm originating from the ventricular surface of the aortic valve was identified. The patient underwent urgent surgical excision and aortic valve replacement. Histopathological examination of the mass confirmed the diagnosis of a myxoma. In conclusion, a myxoma originating from the aortic valve remains a very rare localization. Total resection associated with aortic valve replacement seems to offer an excellent outcome.

  8. Development and experimental characterization of a pneumatic valve actuated by a dielectric elastomer membrane

    Science.gov (United States)

    Hill, Marc; Rizzello, Gianluca; Seelecke, Stefan

    2017-08-01

    Due to their many features including lightweight and low energy consumption, dielectric elastomer (DE) membrane actuators are of interest for a number of industrial applications, such as pumping systems or valve control units. In particular, the use of DEs in valve control units offers advantages over traditional solenoid valves, including lower power requirements and relative simplicity in achieving proportional control. Additionally, DEs generate low thermal dissipation and are capable of virtually silent operation. The contribution of this work is the development of a new valve system based on a circular DE membrane pre-loaded with a linear spring. The valve is designed for pressurized air and operates by actuating a lever mechanism that opens and closes an outlet port. After presenting the operating principle and system design, several experiments are presented to compare actuator force, stroke, and dissipated energy for several pressure differentials and associated volume flows. It is observed that the DE-driven valve achieves a performance similar to a solenoid-based valve, while requiring a significantly lower amount of input energy. In addition, it is shown that DE-membrane valves can be controlled proportionally by simply adjusting the actuator voltage.

  9. A Disposable Dispensing Valve for Non-Contact Microliter Applications in a 96-Well Plate Format

    Directory of Open Access Journals (Sweden)

    Sabrina Kartmann

    2015-04-01

    Full Text Available We present a miniaturized, disposable, normally-closed electromagnetic dispensing valve for the microliter range to process 96-well plates. The novel injection-molded valve is designed to fit into a 9 mm grid to realize an eight channel dispensing head, enabling the serial processing of well plates row-by-row. The presented dispensing valve design originates from a miniaturization study of a previously developed functional model. The outer diameter of the valve, including all actuating components, was reduced by 8 mm to an overall diameter of 8.5 mm without compromising the performance. Additionally, the actuation current of the valve could be reduced to 5 A. The valve is characterized for a volume range between 840 nL and 5.3 μL. The performance of the injection molded valve is competitive to commercially available dispensing valves, featuring the advantages of low fabrication costs, disposability, low mounting size, easy handling, and super silent actuation.

  10. Experimental study on the effect of an artificial cardiac valve on the left ventricular flow

    Science.gov (United States)

    Wang, JiangSheng; Gao, Qi; Wei, RunJie; Wang, JinJun

    2017-09-01

    The use of artificial valves to replace diseased human heart valves is currently the main solution to address the malfunctioning of these valves. However, the effect of artificial valves on the ventricular flow still needs to be understood in flow physics. The left ventricular flow downstream of a St. Jude Medical (SJM) bileaflet mechanical heart valve (BMHV), which is a widely implanted mechanical bileaflet valve, is investigated with time-resolved particle image velocimetry in the current work. A tilting-disk valve is installed on the aortic orifice to guarantee unidirectional flow. Several post-processing tools are applied to provide combined analyses of the physics involved in the ventricular flow. The triple jet pattern that is closely related to the characteristics of the bileaflet valve is discussed in detail from both Eulerian and Lagrangian views. The effects of large-scale vortices on the transportation of blood are revealed by the combined analysis of the tracking of Lagrangian coherent structures, the Eulerian monitoring of the shear stresses, and virtual dye visualization. It is found that the utilization of the SJM BMHV complicates the ventricular flow and could reduce the efficiency of blood transportation. In addition, the kinematics of the bileaflets is presented to explore the effects of flow structures on their motion. These combined analyses could elucidate the properties of SJM BMHV. Furthermore, they could provide new insights into the understanding of other complex blood flows.

  11. System and method for damping vibration in a drill string using a magnetorheological damper

    Science.gov (United States)

    Wassell, Mark Ellsworth [Houston, TX; Burgess, Daniel E [Portland, CT; Barbely, Jason R [East Islip, NY

    2012-01-03

    A system for damping vibration in a drill string can include a magnetorheological fluid valve assembly having a supply of a magnetorheological fluid, a first member, and a second member capable of moving in relation to first member in response to vibration of the drill bit. The first and second members define a first and a second chamber for holding the fluid. Fluid can flow between the first and second chambers in response to the movement of the second member in relation to the first member. The valve assembly can also include a coil for inducing a magnetic field that alters the resistance of the magnetorheological fluid to flow between the first and second chambers, thereby increasing the damping provided by the valve. A remnant magnetic field is induced in one or more components of the magnetorheological fluid valve during operation that can be used to provide the magnetic field for operating the valve so as to eliminate the need to energize the coils during operation except temporarily when changing the amount of damping required, thereby eliminating the need for a turbine alternator power the magnetorheological fluid valve. A demagnetization cycle can be used to reduce the remnant magnetic field when necessary.

  12. Numerical Predictions of Flow Characteristics in a 90 Degree Bended Upward Elbow Located at the Downstream Region of a Flow Control Valve (Butterfly Valve)

    Energy Technology Data Exchange (ETDEWEB)

    Won, Se Youl; Park, Young Sheop; Kim, Yun Jung; Oh, Seung Jong [Korea Hydro and Nuclear Power Co. Ltd., Taejon (Korea, Republic of)

    2006-07-01

    Butterfly valves are widely used in industrial piping components. They are used for flow control in large diameter pipes because of their lightweight, simple structure and the rapidity of manipulation. Any flow disturbing components such as elbows, orifice plates and tees are recommended to be located in a distance of 8 diameters (L/D.8) from the downstream of butterfly valves to decrease the effect of flow disturbance. However, one would encounter cases where other piping components are installed in a close proximity due to the space restriction. In these cases, the numerical simulation will be useful to evaluate the impact of flow disturbances. In this study, we have examined one practical case encountered where the elbow is located in a close proximity to the butterfly valve. Due to the close proximity, we are concerned about pipe thinning and we use the numerical evaluation to determine the range of operating regime and options.

  13. RELIABILITY ANALYSIS OF A HYDRAULIC ON/OFF FAST SWITCHING VALVE

    DEFF Research Database (Denmark)

    Bender, Niels Christian; Pedersen, Henrik Clemmensen; Plöckinger, Andreas

    . Specifically, the mechanical topology of Fast Switching hydraulic Valves (FSVs) are of interest since these undergo operating cycles in the gigacycle regime in theirs functional lifetime. Application of these FSVs is relevant in e.g. digital displacement units, which for the specific design considered...... allowed internal leakage across the valve seat (0.0005 and 0.5 L/min). The study shows that the probability of a low leakage failure is close to 100% before 5 years of operation and 10% risk of high leakage failure after 25 years of operation. Valve seat failure is therefore a potential threat to limit...

  14. Study on the design of industrial control valves with manual drive

    Directory of Open Access Journals (Sweden)

    Pascariu Andrei

    2017-01-01

    Full Text Available The paper presents the main components and the operating mode of the manually operated control valves used in natural gas transport and distribution installations. Main parameters are specified: inlet-outlet pressure (P, temperature(T, flow rate (Q, which are taken into considerations from the design phase and beyond. Noise is another parameter, in close liaison with the pressure and flow. As their value increases with both the inlet noise levels downstream of the valve is greater. By optimizing internal components, especially cages, noise can be limited below the maximum allowed by regulations. Also, there are presented control valve constructive types so that the optimal variant can be chose.

  15. Transcatheter Replacement of Failed Bioprosthetic Valves

    DEFF Research Database (Denmark)

    Simonato, Matheus; Webb, John; Kornowski, Ran

    2016-01-01

    valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51-6.45; P=0.002). Conclusions-High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self-and balloon-expandable transcatheter......Background-Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets...... for implantation that would improve hemodynamics after ViV. Methods and Results-Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated...

  16. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  17. Mechanical systems a unified approach to vibrations and controls

    CERN Document Server

    Gans, Roger F

    2015-01-01

    This essential textbook covers analysis and control of engineering mechanisms, which include almost any apparatus with moving parts used in daily life, from musical instruments to robots. The text  presents both vibrations and controls with considerable breadth and depth using a unified notation. It strikes a nice balance between the analytical and the practical.  This text contains enough material for a two semester sequence, but it can also be used in a single semester course combining the two topics. Mechanical Systems: A Unified Approach to Vibrations and Controls presents a common notation and approach to these closely related areas. Examples from the both vibrations and controls components are integrated throughout this text. This book also: ·         Presents a unified approach to vibrations and controls, including an excellent diagram that simultaneously discusses embedding classical vibrations (mechanical systems) in a discussion of models, inverse models, and open and closed loop control ...

  18. Design and test of a simple fast electromagnetic inductive gas valve for planar pulsed inductive plasma thruster

    Science.gov (United States)

    Guo, Dawei; Cheng, Mousen; Li, Xiaokang

    2017-10-01

    In support of our planar pulsed inductive plasma thruster research, a fast electromagnetic inductive valve for a gas propellant injection system has been built and tested. A new and important design feature is the use of a conical diaphragm as the action part, which greatly contributes to the virtue of simplicity for adopting the resultant force of the diaphragm deformation as the closing force. An optical transmission technique is adopted to measure the opening and closing characters of the valve while the gas throughput is determined by measuring the pressure change per pulse in a test chamber with a capacitance manometer. The experimental results revealed that the delay time before the valve reaction is less than 40 μs, and the valve pulse width is no longer than 160 μs full width at half maximum. The valve delivers 0-2.5 mg of argon gas per pulse varied by adjusting the drive voltage and gas pressure.

  19. Sutureless Valves Reduce Hospital Costs Compared to Traditional Valves.

    Science.gov (United States)

    Laborde, François; Folliguet, Thierry; Ghorayeb, Gabriel; Zannis, Konstantinos

    2017-01-01

    The study aim was to assess differences in clinical outcome, safety, and associated costs between sutureless and aortic isolated aortic valve replacement (AVR) with a standard bioprosthesis. A retrospective comparative study was conducted to investigate 65 patients, each of whom had undergone isolated AVR with a traditional aortic valve (T) or a Perceval S sutureless aortic prosthesis (P) between January 2010 and December 2012. Cost data were drawn from the proprietary cost accounting system of the hospital, excluding acquisition costs of the devices. A linear regression model was used to estimate the mean total costs difference between groups. The mean cardiopulmonary bypass time and aortic cross-clamp times in the T and P groups were 80 ± 41 min and 58 ± 26 min versus 38 ± 16 min and 26 ± 10 min, respectively (p costs savings for group P compared to group T were €3,801 (p = 0.13), mainly driven by hospital stay costs. Savings between the P and T groups increased with age: €4,992 in patients aged 70-79 years and €9,326 in those aged 80+ years, and with risk (€4,296 for high-risk patients). Sutureless aortic valves present shorter procedural times and lower hospital costs compared to traditional valves, with higher cost savings at increased patient age and risk. Sutureless aortic valves seem to be cost-effective in patients undergoing AVR.

  20. Robotically assisted mitral valve replacement.

    Science.gov (United States)

    Gao, Changqing; Yang, Ming; Xiao, Cangsong; Wang, Gang; Wu, Yang; Wang, Jiali; Li, Jiachun

    2012-04-01

    In the present study, we determined the safety and efficacy of robotic mitral valve replacement using robotic technology. From January 2007 through March 2011, more than 400 patients underwent various types of robotic cardiac surgery in our department. Of these, 22 consecutive patients underwent robotically assisted mitral valve replacement. Of the 22 patients with isolated rheumatic mitral valve stenosis (9 men and 13 women), the mean age was 44.7 ± 19.8 years (range, 32-65). Preoperatively, all patients underwent a complete workup, including coronary angiography and transthoracic echocardiography. Of the 22 patients, 15 had concomitant atrial fibrillation. The surgical approach was through 4 right-side chest ports with femoral perfusion. Aortic occlusion was performed with a Chitwood crossclamp, and antegrade cardioplegia was administered directly by way of the anterior chest. Using 3 port incisions in the right side of the chest and a 2.5- to 3.0-cm working port, all the procedures were completed with the da Vinci S robot. All patients underwent successful robotic surgery. Of the 22 patients, 16 received a mechanical valve and 6 a tissue valve. The mean cardiopulmonary bypass time and aortic crossclamp time was 137.1 ± 21.9 minutes (range, 105-168) and 99.3 ± 17.9 minutes (range, 80-133), respectively. No operative deaths, stroke, or other complications occurred, and no incisional conversions were required. After surgery, all the patients were followed up echocardiographically. Robotically assisted mitral valve replacement can be performed safely in patients with isolated mitral valve stenosis, and surgical results are excellent. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  1. Surgical phantom for off-pump mitral valve replacement

    Science.gov (United States)

    McLeod, A. Jonathan; Moore, John; Guiraudon, Gerard M.; Jones, Doug L.; Campbell, Gordon; Peters, Terry M.

    2011-03-01

    Off-pump, intracardiac, beating heart surgery has the potential to improve patient outcomes by eliminating the need for cardiopulmonary bypass and aortic cross clamping but it requires extensive image guidance as well as the development of specialized instrumentation. Previously, developments in image guidance and instrumentation were validated on either a static phantom or in vivo through porcine models. This paper describes the design and development of a surgical phantom for simulating off-pump mitral valve replacement inside the closed beating heart. The phantom allows surgical access to the mitral annulus while mimicking the pressure inside the beating heart. An image guidance system using tracked ultrasound, magnetic instrument tracking and preoperative models previously developed for off-pump mitral valve replacement is applied to the phantom. Pressure measurements and ultrasound images confirm the phantom closely mimics conditions inside the beating heart.

  2. Innovative safety valve selection techniques and data.

    Science.gov (United States)

    Miller, Curt; Bredemyer, Lindsey

    2007-04-11

    The new valve data resources and modeling tools that are available today are instrumental in verifying that that safety levels are being met in both current installations and project designs. If the new ISA 84 functional safety practices are followed closely, good industry validated data used, and a user's maintenance integrity program strictly enforced, plants should feel confident that their design has been quantitatively reinforced. After 2 years of exhaustive reliability studies, there are now techniques and data available to support this safety system component deficiency. Everyone who has gone through the process of safety integrity level (SIL) verification (i.e. reliability math) will appreciate the progress made in this area. The benefits of these advancements are improved safety with lower lifecycle costs such as lower capital investment and/or longer testing intervals. This discussion will start with a review of the different valve, actuator, and solenoid/positioner combinations that can be used and their associated application restraints. Failure rate reliability studies (i.e. FMEDA) and data associated with the final combinations will then discussed. Finally, the impact of the selections on each safety system's SIL verification will be reviewed.

  3. Experiments and Valve Modelling in Thermoacoustic Device

    Science.gov (United States)

    Duthil, P.; Baltean Carlès, D.; Bétrancourt, A.; François, M. X.; Yu, Z. B.; Thermeau, J. P.

    2006-04-01

    In a so called heat driven thermoacoustic refrigerator, using either a pulse tube or a lumped boost configuration, heat pumping is induced by Stirling type thermodynamic cycles within the regenerator. The time phase between acoustic pressure and flow rate throughout must then be close to that met for a purely progressive wave. The study presented here relates the experimental characterization of passive elements such as valves, tubes and tanks which are likely to act on this phase relationship when included in the propagation line of the wave resonator. In order to carry out a characterization — from the acoustic point of view — of these elements, systematic measurements of the acoustic field are performed varying various parameters: mean pressure, oscillations frequency, supplied heat power. Acoustic waves are indeed generated by use of a thermoacoustic prime mover driving a pulse tube refrigerator. The experimental results are then compared with the solutions obtained with various one-dimensional linear models including non linear correction factors. It turns out that when using a non symmetrical valve, and for large dissipative effects, the measurements disagree with the linear modelling and non linear behaviour of this particular element is shown.

  4. What Are the Signs and Symptoms of Heart Valve Disease?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  5. Stem thrust prediction model for W-K-M double wedge parallel expanding gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Eldiwany, B.; Alvarez, P.D. [Kalsi Engineering Inc., Sugar Land, TX (United States); Wolfe, K. [Electric Power Research Institute, Palo Alto, CA (United States)

    1996-12-01

    An analytical model for determining the required valve stem thrust during opening and closing strokes of W-K-M parallel expanding gate valves was developed as part of the EPRI Motor-Operated Valve Performance Prediction Methodology (EPRI MOV PPM) Program. The model was validated against measured stem thrust data obtained from in-situ testing of three W-K-M valves. Model predictions show favorable, bounding agreement with the measured data for valves with Stellite 6 hardfacing on the disks and seat rings for water flow in the preferred flow direction (gate downstream). The maximum required thrust to open and to close the valve (excluding wedging and unwedging forces) occurs at a slightly open position and not at the fully closed position. In the nonpreferred flow direction, the model shows that premature wedging can occur during {Delta}P closure strokes even when the coefficients of friction at different sliding surfaces are within the typical range. This paper summarizes the model description and comparison against test data.

  6. Mitral valve aneurysm associated with aortic valve endocarditis and regurgitation.

    Science.gov (United States)

    Raval, Amish N; Menkis, Alan H; Boughner, Derek R

    2002-01-01

    Mitral valve aneurysms are rare complications occurring most commonly in association with aortic valve infective endocarditis. [Decroly 1989, Chua 1990, Northridge 1991, Karalis 1992, Roguin 1996, Mollod 1997, Vilacosta 1997, Cai 1999, Vilacosta 1999, Teskey 1999, Chan 2000, Goh 2000, Marcos- Alberca 2000] While the mechanism of the development of this lesion is unclear, complications such as perforation can occur and lead to significant mitral regurgitation. [Decroly 1989, Karalis 1992, Teskey 1999, Vilacosta 1999]; The case of a 69-year-old male with Streptococcus Sanguis aortic valve endocarditis and associated anterior mitral leaflet aneurysm is presented. Following surgery, tissue pathology of the excised lesion revealed myxomatous degeneration and no active endocarditis or inflammatory cells. This may add support to the hypothesis that physical stress due to severe aortic insufficiency and structural weakening, without infection of the anterior mitral leaflet, can lead to the development of this lesion.

  7. Valved stent for off-pump mitral valve replacement

    OpenAIRE

    Ma, L.(School of Physics, Shandong University, Shandong, China)

    2004-01-01

    Résumé Objectif : Evaluer un remplacement de valve mitrale hors-pompe avec des stents valvés Méthode: Des homografts préservés dans du glutaraldehyde ont été suturés dans une prothèse tubulaire avant d'être soudés à deux stents Z en nitinol pour créer deux couronnes auto- extensibles. A) Nous avons testé la valve in vitro en utilisant un circuit pulsatile fermé (mock loop) ayant de débuter les expériences sur les porcs. (n=8, 46 .0± 4.3 kg : B). L'oreillette gauche a été exposée p...

  8. Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

    Science.gov (United States)

    Burkhardt, Wendel M.; Crapuchettes, John M.; Addona, Brad M.; Polzin, Kurt A.

    2015-01-01

    It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since

  9. Resonant vibration control of wind turbine blades

    DEFF Research Database (Denmark)

    Svendsen, Martin Nymann; Krenk, Steen; Høgsberg, Jan Becker

    2010-01-01

    The paper deals with introduction of damping to specific vibration modes of wind turbine blades, using a resonant controller with acceleration feedback. The wind turbine blade is represented by three-dimensional, two-node finite elements in a local, rotating frame of reference. The element....... The efficiency of the resonant controller is demonstrated for a representative turbine blade exposed to turbulent wind loading. It is found that the present explicit tuning procedure yields close to optimal tuning, with very limited modal spill-over and effective reduction of the vibration amplitudes....

  10. Minimally Invasive Heart Valve Surgery.

    Science.gov (United States)

    Bouhout, Ismail; Morgant, Marie-Catherine; Bouchard, Denis

    2017-09-01

    Minimally invasive valve surgery represents a recent and significant advance in modern heart surgery. Indeed, many less invasive approaches for both the aortic and mitral valves have been developed in the past 2 decades. These procedures were hypothesized to result in less operative trauma, which might translate into better patient outcomes. However, this clinical benefit remains controversial in the literature. The aim of this review is to discuss the evidence surrounding minimally invasive heart valve surgery in the current era. A systematic search of the literature from 2006-2016 was performed looking for articles reporting early or late outcomes after minimally invasive valve surgery. Less invasive valve surgery is safe and provides long-term surgical outcomes similar to those of standard sternotomy. In addition, these approaches result in a reduction in overall hospital length of stay and may mitigate the risk of early morbidity-mainly postoperative bleeding, transfusions, and ventilation duration. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  11. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive...... in Denmark who had received a Mitroflow aortic bioprosthesis since 2000. METHODS: Patients alive in Denmark with a Mitroflow bioprosthesis implanted since January 2000 were invited to participate in a nationwide cross-sectional study with a predefined definition of SVD. Of 1552 patients, 861 patients had...

  12. Sliding-gate valve for use with abrasive materials

    Science.gov (United States)

    Ayers, Jr., William J.; Carter, Charles R.; Griffith, Richard A.; Loomis, Richard B.; Notestein, John E.

    1985-01-01

    The invention is a flow and pressure-sealing valve for use with abrasive solids. The valve embodies special features which provide for long, reliable operating lifetimes in solids-handling service. The valve includes upper and lower transversely slidable gates, contained in separate chambers. The upper gate provides a solids-flow control function, whereas the lower gate provides a pressure-sealing function. The lower gate is supported by means for (a) lifting that gate into sealing engagement with its seat when the gate is in its open and closed positions and (b) lowering the gate out of contact with its seat to permit abrasion-free transit of the gate between its open and closed positions. When closed, the upper gate isolates the lower gate from the solids. Because of this shielding action, the sealing surface of the lower gate is not exposed to solids during transit or when it is being lifted or lowered. The chamber containing the lower gate normally is pressurized slightly, and a sweep gas is directed inwardly across the lower-gate sealing surface during the vertical translation of the gate.

  13. Development of mechanical heart valves - an inspiring tale

    Directory of Open Access Journals (Sweden)

    P Rajashekar

    2015-01-01

    Full Text Available The historical evolution of the prosthetic heart valves from the first attempts with the Hufnagel′s valve in the treatment of the aortic insufficiency to the Starr-Edwards′ ball valve and later the tilting disc valves (Bjork-Shiley etc., and finally the bileaflet valves (St. Jude are discussed. The Indian contribution with Chitra valve is also described.

  14. Model Indepedent Vibration Control

    OpenAIRE

    Yuan, Jing

    2010-01-01

    A NMIFC system is proposed for broadband vibration control. It has two important features. Feature F1 is that the NMIFC is stable without introducing any invasive effects, such as probing signals or controller perturbations, into the vibration system; feature F2 is

  15. Vibration Theory, Vol. 3

    DEFF Research Database (Denmark)

    Nielsen, Søren R. K.

    The present textbook has been written based on previous lecture notes for a course on stochastic vibration theory that is being given on the 9th semester at Aalborg University for M. Sc. students in structural engineering. The present 4th edition of this textbook on linear stochastic vibration...

  16. Vibration Theory, Vol. 3

    DEFF Research Database (Denmark)

    Nielsen, Søren R. K.

    The present textbook has been written based on previous lecture notes for a course on stochastic vibration theory that is being given on the 9th semester at Aalborg University for M. Sc. students in structural engineering. The present 2nd edition of this textbook on linear stochastic vibration...

  17. Hydroelastic Vibrations of Ships

    DEFF Research Database (Denmark)

    Jensen, Jørgen Juncher; Folsø, Rasmus

    2002-01-01

    A formula for the necessary hull girder bending stiffness required to avoid serious springing vibrations is derived. The expression takes into account the zero crossing period of the waves, the ship speed and main dimensions. For whipping vibrations the probability of exceedance for the combined...

  18. Gearbox vibration diagnostic analyzer

    Science.gov (United States)

    1992-01-01

    This report describes the Gearbox Vibration Diagnostic Analyzer installed in the NASA Lewis Research Center's 500 HP Helicopter Transmission Test Stand to monitor gearbox testing. The vibration of the gearbox is analyzed using diagnostic algorithms to calculate a parameter indicating damaged components.

  19. Mechanical vibration and shock analysis, sinusoidal vibration

    CERN Document Server

    Lalanne, Christian

    2014-01-01

    Everything engineers need to know about mechanical vibration and shock...in one authoritative reference work! This fully updated and revised 3rd edition addresses the entire field of mechanical vibration and shock as one of the most important types of load and stress applied to structures, machines and components in the real world. Examples include everything from the regular and predictable loads applied to turbines, motors or helicopters by the spinning of their constituent parts to the ability of buildings to withstand damage from wind loads or explosions, and the need for cars to m

  20. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves

    Science.gov (United States)

    van Rensburg, Annari; Doubell, Anton

    2017-01-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P abnormal papillary muscles (P = 0.002) and an additional chord or tendon in the left ventricle cavity (P = 0.007). Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. PMID:28515127

  1. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  2. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves.

    Science.gov (United States)

    van Rensburg, Annari; Herbst, Philip; Doubell, Anton

    2017-06-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P mitral regurgitation (P Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. © 2017 The authors.

  3. Should a Regurgitant Mitral Valve Be Replaced Simultaneously with a Stenotic Aortic Valve?

    OpenAIRE

    Christenson, Jan T.; Jordan, Bernard; Bloch, Antoine; Schmuziger, Martin

    2000-01-01

    Mitral valve regurgitation frequently accompanies aortic valve stenosis. It has been suggested that mitral regurgitation improves after aortic valve replacement alone and that the mitral valve need not be replaced simultaneously. Furthermore, mitral regurgitation associated with coronary artery disease, particularly in patients with poor left ventricular function, shows immediate improvement after coronary artery bypass grafting.

  4. Vibrations of rotating machinery

    CERN Document Server

    Matsushita, Osami; Kanki, Hiroshi; Kobayashi, Masao; Keogh, Patrick

    2017-01-01

    This book opens with an explanation of the vibrations of a single degree-of-freedom (dof) system for all beginners. Subsequently, vibration analysis of multi-dof systems is explained by modal analysis. Mode synthesis modeling is then introduced for system reduction, which aids understanding in a simplified manner of how complicated rotors behave. Rotor balancing techniques are offered for rigid and flexible rotors through several examples. Consideration of gyroscopic influences on the rotordynamics is then provided and vibration evaluation of a rotor-bearing system is emphasized in terms of forward and backward whirl rotor motions through eigenvalue (natural frequency and damping ratio) analysis. In addition to these rotordynamics concerning rotating shaft vibration measured in a stationary reference frame, blade vibrations are analyzed with Coriolis forces expressed in a rotating reference frame. Other phenomena that may be assessed in stationary and rotating reference frames include stability characteristic...

  5. Active combustion flow modulation valve

    Science.gov (United States)

    Hensel, John Peter; Black, Nathaniel; Thorton, Jimmy Dean; Vipperman, Jeffrey Stuart; Lambeth, David N; Clark, William W

    2013-09-24

    A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

  6. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  7. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  8. Pregnancy-induced remodeling of heart valves.

    Science.gov (United States)

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves. Copyright © 2015 the American Physiological Society.

  9. Hydraulic System Design of Hydraulic Actuators for Large Butterfly Valves

    Directory of Open Access Journals (Sweden)

    Ye HUANG

    2014-09-01

    Full Text Available Hydraulic control systems of butterfly valves are presently valve-controlled and pump-controlled. Valve-controlled hydraulic systems have serious power loss and generate much heat during throttling. Pump-controlled hydraulic systems have no overflow or throttling losses but are limited in the speed adjustment of the variable-displacement pump, generate much noise, pollute the environment, and have motor power that does not match load requirements, resulting in low efficiency under light loads and wearing of the variable-displacement pump. To overcome these shortcomings, this article designs a closed hydraulic control system in which an AC servo motor drives a quantitative pump that controls a spiral swinging hydraulic cylinder, and analyzes and calculates the structure and parameters of a spiral swinging hydraulic cylinder. The hydraulic system adjusts the servo motor’s speed according to the requirements of the control system, and the motor power matches the power provided to components, thus eliminating the throttling loss of hydraulic circuits. The system is compact, produces a large output force, provides stable transmission, has a quick response, and is suitable as a hydraulic control system of a large butterfly valve.

  10. Mathematical multi-scale model of the cardiovascular system including mitral valve dynamics. Application to ischemic mitral insufficiency

    Science.gov (United States)

    2011-01-01

    Background Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. Methods A cardiovascular and circulatory system (CVS) model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Results Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV) loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. Conclusions The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves. PMID:21942971

  11. Comparison of cellular changes in Cavalier King Charles spaniel and mixed breed dogs with myxomatous mitral valve disease.

    Science.gov (United States)

    Lu, C-C; Liu, M-M; Culshaw, G; French, A; Corcoran, B

    2016-06-01

    The aim of this study was to determine if there are differences in cellular changes in Cavalier King Charles spaniel (CKCS) myxomatous mitral valves compared to non-CKCS dogs. Cavalier King Charles spaniels (n = 6) and age-matched mixed breed (n = 6) with severe myxomatous mitral valve disease (MMVD), and normal mixed breed (n = 4) dogs. Immunohistochemistry staining and qualitative and quantitative analysis of mitral valves sections, examining for the presence of CD11c and CD45, vimentin, alpha smooth muscle actin (α-SMA) and embryonic smooth muscle myosin heavy chain (Smemb), von Willebrand factor and CD31 and Ki-67. Vimentin positive cell numbers were increased in the MMVD dogs and distributed throughout the valve with greatest density close to the endothelium. There were no significant differences in cell marker expression for the two diseased groups, but cell numbers were significantly increased compared to controls for α-SMA (CKCS only) and Smemb (CKCS and mixed breed: p < 0.05). Alpha smooth muscle actin+ cells were primarily located at the valve edge, with Smemb+ cells similarly located, but also present throughout the valve stroma. A small number of cells close to the valve edge co-expressed α-SMA and Smemb. Endothelial von Willebrand factor expression was identified in all valves, with evidence of disrupted endothelium in the diseased, but was also found in diseased valve stroma. There was no staining for CD11c, CD45 or CD31 in any valve. Ki-67+ cells formed linear clusters at the leaflet tip and were sparsely distributed throughout both myxomatous valve groups. The cellular changes notes with advanced stage MMVD appear similar for CKCS when compared to mixed breed dogs. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Mathematical multi-scale model of the cardiovascular system including mitral valve dynamics. Application to ischemic mitral insufficiency

    Directory of Open Access Journals (Sweden)

    Moonen Marie

    2011-09-01

    Full Text Available Abstract Background Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. Methods A cardiovascular and circulatory system (CVS model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Results Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. Conclusions The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves.

  13. Fluid–Structure Interaction Analysis of Papillary Muscle Forces Using a Comprehensive Mitral Valve Model with 3D Chordal Structure

    Energy Technology Data Exchange (ETDEWEB)

    Toma, Milan; Jensen, Morten Ø.; Einstein, Daniel R.; Yoganathan, Ajit P.; Cochran, Richard P.; Kunzelman, Karyn S.

    2015-07-17

    Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid-structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in-vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves were mounted in an in vitro setup, and structural data for the mitral valve was acquired with *CT. Experimental data from the in-vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed lea et dynamics, and force vectors from the in-vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements are important in validating and adjusting material parameters in computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.

  14. 49 CFR 195.420 - Valve maintenance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance. 195.420 Section 195.420 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Operation and Maintenance § 195.420 Valve maintenance. (a) Each operator shall maintain each valve...

  15. Double orifice mitral valve; a coincidental finding

    NARCIS (Netherlands)

    Westendorp, Iris C. D.; de Bruin-Bon, H. A. C. M.; Hrudova, Jana

    2006-01-01

    A double orifice mitral valve (DOMV) represents a rare congenital malformation characterised by two valve orifices with two separate subvalvular apparatus. This case demonstrates the necessity of careful imaging of the mitral valve apparatus, not only in patients with atrioventricular septal

  16. Pregnancy in women with prosthetic heart valves

    NARCIS (Netherlands)

    Pieper, P. G.; Balci, A.; Van Dijk, A. P.

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis mid death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than unfractionated and low-molecular-weight heparin, but carry the risk

  17. Pregnancy in women with prosthetic heart valves.

    NARCIS (Netherlands)

    Pieper, P.G.; Balci, A.; Dijk, A.P.J. van

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis and death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than un-fractionated and low-molecular-weight heparin, but carry the risk

  18. Transcatheter mitral valve implantation via transapical approach

    DEFF Research Database (Denmark)

    Sondergaard, Lars; Brooks, Matthew; Ihlemann, Nikolaj

    2015-01-01

    OBJECTIVES: As many as 50% of patients with severe symptomatic mitral valve regurgitation are denied surgical valve replacement or repair due to high operative risk. We describe an early series of cases of transcatheter implantation with a CardiAQ™ mitral valve via a transapical approach. METHODS...

  19. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  20. Porcine Tricuspid Valve Anatomy and Human Compatibility

    DEFF Research Database (Denmark)

    Waziri, Farhad; Lyager Nielsen, Sten; Hasenkam, J. Michael

    2016-01-01

    before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. METHODS: The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin...

  1. Chatter vibrations of high-performance motorcycles

    Science.gov (United States)

    Sharp, R. S.; Watanabe, Y.

    2013-03-01

    Motorcycle racing teams occasionally experience speed-limiting vibrations of around 25 Hz frequency in mid-corner. The nature of the vibrations has not been closely defined yet and the mechanics are currently not properly understood. Conventional motorcycle-dynamics models are shown here to reveal the existence of a vibration mode that aligns with the experience being referred to, suggesting some explanations. Root loci for variations in speed or cornering vigour, demonstrating modal characteristics for small perturbations from trim states, are employed to indicate how the mode responds to changes in operation and design. Modal participation is examined for a lightly damped case. Influences on the natural frequency and damping of the mode are found and a way of stabilising the mode is suggested.

  2. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  3. [The Starr-Edwards heart valve: one of the oldest mechanical heart valves still functioning today].

    Science.gov (United States)

    Schoenaker, Michiel H; van Wetten, Herbert B; Morshuis, Wim J

    2015-01-01

    In the 1960s, the Starr-Edwards valve was the first artificial heart valve to be successfully implanted in humans. This valve has now been in use for decades with outstanding results: patients whose life expectancy had previously been short acquired a good prognosis with this development. Nowadays the Starr-Edwards valve is not used anymore, but patients are being described today in whom these valves are still functioning well after more than 40 years.

  4. A Water Hammer Protection Method for Mine Drainage System Based on Velocity Adjustment of Hydraulic Control Valve

    Directory of Open Access Journals (Sweden)

    Yanfei Kou

    2016-01-01

    Full Text Available Water hammer analysis is a fundamental work of pipeline systems design process for water distribution networks. The main characteristics for mine drainage system are the limited space and high cost of equipment and pipeline changing. In order to solve the protection problem of valve-closing water hammer for mine drainage system, a water hammer protection method for mine drainage system based on velocity adjustment of HCV (Hydraulic Control Valve is proposed in this paper. The mathematic model of water hammer fluctuations is established based on the characteristic line method. Then, boundary conditions of water hammer controlling for mine drainage system are determined and its simplex model is established. The optimization adjustment strategy is solved from the mathematic model of multistage valve-closing. Taking a mine drainage system as an example, compared results between simulations and experiments show that the proposed method and the optimized valve-closing strategy are effective.

  5. Aortic valve replacement in a patient with ostegenesis imperfecta A case report.

    Science.gov (United States)

    Concistrè, Giovanni; Casali, Giovanni; Della Monica, Paola Lilla; Montalto, Andrea; Ranocchi, Federeico; Fiorani, Brenno; Musumeci, Francesco

    2014-01-01

    Osteogenesis imperfecta (OI) is an inherited connective tissue disorder in which fragile bones readily cause fractures. Aortic root dilatation, aortic valve regurgitation and mitral valve prolapse are uncommon cardiovascular manifestations of OI. Cardiac surgery in these patients carries a high risk of complications due to increased tissue and capillary fragility. We describe an open heart surgery in a woman with isolated aortic valve regurgitation secondary to OI. A 58-year-old woman was referred to our hospital for surgical correction of aortic valve regurgitation. She had a past history of recurrent long bone fractures, and OI was diagnosed in the childhood. A standard median sternotomy was performed; the sternum was found to be thin and brittle. The native aortic valve was replaced with a size 23 mm stented aortic bioprosthesis. The sternum was closed with stainless steel wires. The postoperative course was uneventful, and the patient was discharged home on the eighth postoperative day. We used thoracic band to avoid sternal diastasis. One year postoperatively, the echocardiogram showed a normal aortic bioprosthesis function without paravalvular leakage. The sternum was stable without dehiscence. The mortality rate in cardiac surgery patients with heritable generalized connective tissue disorders, such as osteogenesis imperfecta, is high. Although tissue friability had no impact on surgical outcome, it should be kept in mind when operating on patients with OI. We highlight the importance of a meticulous surgical technique, together with a strategy for management of anticipated perioperative complications to ensure a successful outcome. Aortic valve, Endocardirtis, Mitral valve, Replacement.

  6. Comparative classification of thrombotic formations on bileaflet mechanical heart valves by phonographic analysis.

    Science.gov (United States)

    Romata, Clemens; Susin, Francesca Maria; Cambi, Andrea; Tarzia, Vincenzo; Pengo, Vittorio; Gerosa, Gino; Bagno, Andrea

    2011-06-01

    Haemodynamic performance of bileaflet mechanical heart valves can be severely affected by the formation of thrombotic deposits. Hence, early detection of thrombi is fundamental for a prompt diagnosis and adequate therapy. This article aims at designing a novel diagnostic and prognostic tool able to detect valvular thrombosis at early stages of formation, i.e., before the appearance of critical symptoms in patients who can be effectively treated by pharmacological therapy, preventing re-operation. This approach relies on the acquisition of the acoustic signals produced by mechanical heart valves in the closing phase; the corresponding power spectra are then analysed by means of artificial neural networks trained to identify the presence of thrombi and classify their occurrence. Five commercial bileaflet mechanical heart valves were investigated in vitro in a Sheffield Pulse Duplicator; for each valve six functional conditions were considered, each corresponding to a risk class for patients (one normofunctioning and five thrombosed): they have been simulated by placing artificial deposits of increasing weight and different shape on the valve leaflet and on the annular housing; the case of one completely blocked leaflet was also investigated. These six functional conditions represent risk classes: they were examined under various hydrodynamic regimes. The acoustic signals produced by the valves were acquired by means of a phonocardiographic apparatus, then analysed and classified. The ability to detect and classify thrombotic formations on mechanical valve leaflet would allow ranking patients by assigning them to one of the six risk classes, helping clinicians in establish adequate therapeutic approaches.

  7. Tricuspid valve repair for severe tricuspid regurgitation due to pacemaker leads.

    Science.gov (United States)

    Uehara, Kyokun; Minakata, Kenji; Watanabe, Kentaro; Sakaguchi, Hisashi; Yamazaki, Kazuhiro; Ikeda, Tadashi; Sakata, Ryuzo

    2016-07-01

    Tricuspid valve regurgitation due to pacemaker leads is a well-known complication. Although some reports have suggested that pacemaker leads should be surgically explanted, strongly adhered leads cannot always be removed. The aim of this study was to describe our tricuspid valve repair techniques with pacemaker leads left in situ. Our retrospective study investigated 6 consecutive patients who required tricuspid valve surgery for severe regurgitation induced by pacemaker leads. From the operative findings, we identified 3 patterns of tricuspid valve and pacemaker lead involvement. In 3 patients, the leads were caught in the chordae, in 2 patients, tricuspid regurgitation was caused by lead impingement on the septal leaflet, and in 3 patients, tricuspid valve leaflets had been perforated by the pacemaker leads. During surgery, all leads were left in situ after being separated from the leaflet or valvular apparatus. In addition, suture annuloplasty was performed for annular dilatation in all cases. In one patient, the lead was reaffixed to the annulus after the posterior leaflet was cut back towards the annulus, and the leaflet was then closed. There was one hospital death due to sepsis. The degree of tricuspid regurgitation was trivial in all surviving patients at discharge. During a mean follow-up of 21 months, one patient died from pneumonia 20 months after tricuspid valve repair. In patients undergoing tricuspid valve surgery due to severe tricuspid regurgitation caused by pacemaker leads, the leads can be left in situ after proper repair with annuloplasty. © The Author(s) 2016.

  8. Events extraction for the power signatures of the motor-operated valves using an specialist system; Modulo de extracao de eventos em assinaturas de potencia de valvulas moto-operadas usando um sistema especialista

    Energy Technology Data Exchange (ETDEWEB)

    Perrenoud, Helena Guimaraes; Silva, Aucyone Augusto da [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2002-07-01

    A predictive maintenance program for motor-operated valves is performed every year at Angra I Nuclear Power Plant in order to detect early failures of the valves and to diagnosis the valve degradation. The purpose of this maintenance program is to increase the reactor reliability and security. The main predictive maintenance activities are usually performed in the Swing check-valves, gate valves and globe valves. The valves data analysis usually performed during the plant outage allows one to detect any failure and adjust the valves parameters like torque-switch and limitorque. The main purpose of this thesis is to develop a computer program to select the valve events parameter using the valve power signature during the closed-open and open-closed cycles. The results obtained by the developed algorithm are connected to a developed specialist system to perform the valves events identification. An important contribution of this thesis is that the valves signature features are obtained without changing the signal morphology. (author)

  9. Priming the Ahmed Glaucoma Valve: pressure required and effect of overpriming.

    Science.gov (United States)

    Cheng, Jason; Abolhasani, Milad; Beltran-Agullo, Laura; Moss, Edward Bram; Buys, Yvonne M; Trope, Graham E

    2015-01-01

    To determine the pressure required to prime an Ahmed Glaucoma Valve (AGV) and determine whether the valve can be damaged by "over-priming pressure." Three AGVs, a syringe pump, and a manometer were used to assess priming pressure. Balanced salt solution was pumped through the AGV tube at increasing pressures until a jet of fluid was seen to eject from the AGV, as per manufacturer instructions. This was repeated 3 times for 3 different virgin AGVs giving the "priming pressure." A second experiment used the same experimental set up to determine the "over-priming pressure" on 3 other AGVs. Fluid was pumped through the AGV at increasing pressures until evidence of damage was seen. The valve function was assessed before and after the "over-priming" stress test. Valve function was determined by the closing pressure, which is the pressure at which the valve closes and fluid was no longer seen passing through the valve. The priming pressure in the 3 AGVs was 2844, 3154, and 3051 mm Hg (mean, 3017±158 mm Hg). The maximum pressure generated using the syringe pump was 10,860, 10,343, and 10,860 mm Hg (mean, 10,688±299 mm Hg). No damage was observed in the valve mechanism. AGV closing pressure before the "over-priming" stress test was 8, 6, and 13 mm Hg and after the stress test was 6, 7, and 13 mm Hg. This study demonstrates that the priming pressure is consistent at around 3000 mm Hg. In addition, over-priming is not likely to damage or disturb the closing pressure.

  10. VLTI-UT vibrations effort and performances

    Science.gov (United States)

    Poupar, Sébastien; Haguenauer, Pierre; Alonso, Jaime; Schuhler, Nicolas; Henriquez, Juan-Pablo; Berger, Jean-Philippe; Bourget, Pierre; Brillant, Stephane; Castillo, Roberto; Gitton, Philippe; Gonte, Frederic; Di Lieto, Nicola; Lizon, Jean-Louis; Merand, Antoine; Woillez, Julien

    2014-07-01

    The ESO Very Large Telescope Interferometer (VLTI) using the Unit Telescope (UT) was strongly affected by vibrations since the first observations. Investigation by ESO on that subject had started in 2007, with a considerable effort since mid 2008. An important number of investigations on various sub-systems (On telescope: Guiding, Passive supports, Train Coude, insulation of electronics cabinets; On Instruments: dedicated campaign on each instruments with a special attention on the ones equipped with Close Cycle Cooler) were realized. Vibrations were not only recorded and analyzed using the usual accelerometers but also using on use sub-systems as InfRared Image Sensor (IRIS) and Multiple Applications Curvature Adaptive Optics (MACAO) and using a specific tool developed for vibrations measurements Mirror vibrAtion Metrology systeM for the Unit Telescope (MAMMUT). Those tools and systems have been used in order to improve the knowledge on telescope by finding sources. The sources whenever it was possible were damped. As known for years, instruments are still the principal sources of vibrations, for the majority of the UT. A special test in which 2 UTs instruments were completely shut down was realized to determine the minimum Optical Path Length (OPL) achievable. Vibrations is now a part of the instruments interface document and during the installation of any new instrument (KMOS) or system (AOF) a test campaign is realized. As a result some modifications (damping of CCC) can be asked in case of non-compliance. To ensure good operational conditions, levels of vibrations are regularly recorded to control any environmental change.

  11. Mechanism for cavitation in the mechanical heart valve with an artificial heart: nuclei and viscosity dependence.

    Science.gov (United States)

    Lee, Hwansung; Taenaka, Yoshiyuki; Kitamura, Soichiro

    2005-01-01

    Until now, we have estimated cavitation for mechanical heart valves (MHV) mounted in an electrohydraulic total artificial heart (EHTAH) with tap water. However, tap water at room temperature is not a proper substitute for blood at 37 degrees C. We therefore investigated fluid characterization in studies of MHV cavitation associated with the viscosity and nuclei content of a testing fluid. We used the Medtronic Hall valve mounted in the mitral position of the EHTAH. As testing fluids, tap water, distilled water, and glycerin solution were used. The valve-closing velocity, pressure-drop measurements, and a high-speed video camera were employed to determine the cavitation intensity in MHV. Most of the cavitation bubbles were observed at the edge of the valve stop. Our analysis of the results indicates that squeeze flow is the major cause of cavitation in the Medtronic Hall valve. The cavitation intensity increased with increases in the fluid viscosity and the valve-closing velocity. Even if cavitation intensity in glycerin solution was greater, the cavitation occurrence probability was less in glycerin solution than in tap water. Our results suggest that tap water contains particles that cause an increase in the cavitation occurrence probability. We conclude that cavitation intensity is greatly affected by the nuclei concentration in the fluid and the fluid viscosity.

  12. Structural Stability and Vibration

    DEFF Research Database (Denmark)

    Wiggers, Sine Leergaard; Pedersen, Pauli

    This book offers an integrated introduction to the topic of stability and vibration. Strikingly, it describes stability as a function of boundary conditions and eigenfrequency as a function of both boundary conditions and column force. Based on a post graduate course held by the author at the Uni......This book offers an integrated introduction to the topic of stability and vibration. Strikingly, it describes stability as a function of boundary conditions and eigenfrequency as a function of both boundary conditions and column force. Based on a post graduate course held by the author...... and their derivation, thus stimulating them to write interactive and dynamic programs to analyze instability and vibrational modes....

  13. Imaging of Cardiac Valves by Computed Tomography

    OpenAIRE

    Gudrun Feuchtner

    2013-01-01

    This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use ...

  14. Field Experience with Lock Culvert Valves

    Science.gov (United States)

    2013-12-01

    interesting accounts regarding their lock culvert valves. ST. LAWRENCE SEAWAY Eisenhower and Snell Locks. The valves on the Eisenhower and Snell Locks...Tainter Valve Design Lift, ft Eisenhower St. Lawrence Seaway 80 x 860 12 x 14 21.0 DSP 43 Snell St. Lawrence Seaway 80 x 860 12 x 14 21.0 3 DSP, 1 VF 49...vertical-frame valves were furnished to the SLSDC in January 2011, and one was installed in the south filling-valve location at Snell Lock. An option

  15. Heart sounds as a result of acoustic dipole radiation of heart valves

    Science.gov (United States)

    Kasoev, S. G.

    2005-11-01

    Heart sounds are associated with impulses of force acting on heart valves at the moment they close under the action of blood-pressure difference. A unified model for all the valves represents this impulse as an acoustic dipole. The near pressure field of this dipole creates a distribution of the normal velocity on the breast surface with features typical of auscultation practice: a pronounced localization of heart sound audibility areas, an individual area for each of the valves, and a noncoincidence of these areas with the projections of the valves onto the breast surface. In the framework of the dipole theory, the optimum size of the stethoscope’s bell is found and the spectrum of the heart sounds is estimated. The estimates are compared with the measured spectrum.

  16. A method for evaluating pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, T.

    1996-12-01

    A method is described to evaluate the susceptibility of gate valves to pressure locking and thermal binding. Binding of the valve disc in the closed position due to high pressure water trapped in the bonnet cavity (pressure locking) or differential thermal expansion of the disk in the seat (thermal binding) represents a potential mechanism that can prevent safety-related systems from functioning when called upon. The method described here provides a general equation that can be applied to a given gate valve design and set of operating conditions to determine the susceptibility of the valve to fail due to disc binding. The paper is organized into three parts. The first part discusses the physical mechanisms that cause disc binding. The second part describes the mathematical equations. The third part discusses the conclusions.

  17. Effect of periodic aerodynamic pulsation on flow over a confined butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Caille, V.; Laumonier, J. [Poitiers Univ., 86 (France). Centre d`Etudes Aerodynamiques et Thermiques

    1998-09-01

    An experimental investigation of the flowfield characteristics of a butterfly valve under periodic flow has been made. The results concern a valve at large angles corresponding to high area contraction ratios (K>0.3). In steady flow, the results show that the flowfield within the valve is conditioned by the internal jet formed in the trailing edge fluid area. For very high area contraction ratios (K>0.65), the equivalent diameter of that fluid area is the preponderant length scale of the flow. In periodic flow, an increase in the length scale of flow instabilities is observed. The reorganization length of the flow is, thus, shorter, producing a marked reduction in valve head-loss. This phenomen is maximum when the excitation frequency is close to the nominal instabilities frequency (found in steady flow). (orig.) With 10 figs., 19 refs.

  18. Effect of periodic aerodynamic pulsation on flow over a confined butterfly valve

    Science.gov (United States)

    Caillé, V.; Laumonier, J.

    An experimental investigation of the flowfield characteristics of a butterfly valve under periodic flow has been made. The results concern a valve at large angles corresponding to high area contraction ratios (K>0.3). In steady flow, the results show that the flowfield within the valve is conditioned by the internal jet formed in the trailing edge fluid area. For very high area contraction ratios (K>0.65), the equivalent diameter of that fluid area is the preponderant length scale of the flow. In periodic flow, an increase in the length scale of flow instabilities is observed. The reorganization length of the flow is, thus, shorter, producing a marked reduction in valve head-loss. This phenomen is maximum when the excitation frequency is close to the nominal instabilities frequency (found in steady flow).

  19. Optimization of geometry of annular seat valves suitable for Digital Displacement fluid power pumps/motors

    DEFF Research Database (Denmark)

    Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.

    2013-01-01

    work an annular seat valve suitable for use in Digital Displacement units is considered, and the ring geometry is optimized using finite element analysis including non-linear material behaviour, contact elements and fluid pressure penetrating load, closely reflecting the actual load of the seat valve......Digital Displacement Fluid Power is an upcoming technology setting new standards for the achievable efficiency of fluid power pumps and motors. The core element of the Digital Displacement technology is high performance electronically controlled seat valves, which must exhibit very low flow...... pressure loss and switching times within a few milliseconds to enable high efficiency operation. These valves are mechatronic components and special attention to both the mechanical, electromagnetic, fluid dynamical and control system design must be paid to ensure the needed performance. In the present...

  20. Isolated tricuspid valve infective endocarditis

    African Journals Online (AJOL)

    1990-07-07

    Jul 7, 1990 ... Case 2. Initial chest radiograph showing rounded shadows with cavitation. Fig. 2. Case 2. Chest radiograph showing progression to effusion. nuc/eacum was Isolated from repeated blood cultures. Two- dimensional echocardiography revealed vegetations on the tricuspid valve (Fig. 3). The patient was now ...

  1. Optothermally actuated capillary burst valve

    DEFF Research Database (Denmark)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders

    2017-01-01

    be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett...

  2. Mitral valve surgery - minimally invasive

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  3. Aortic valve surgery - minimally invasive

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  4. Hemodynamics driven cardiac valve morphogenesis.

    Science.gov (United States)

    Steed, Emily; Boselli, Francesco; Vermot, Julien

    2016-07-01

    Mechanical forces are instrumental to cardiovascular development and physiology. The heart beats approximately 2.6 billion times in a human lifetime and heart valves ensure that these contractions result in an efficient, unidirectional flow of the blood. Composed of endocardial cells (EdCs) and extracellular matrix (ECM), cardiac valves are among the most mechanically challenged structures of the body both during and after their development. Understanding how hemodynamic forces modulate cardiovascular function and morphogenesis is key to unraveling the relationship between normal and pathological cardiovascular development and physiology. Most valve diseases have their origins in embryogenesis, either as signs of abnormal developmental processes or the aberrant re-expression of fetal gene programs normally quiescent in adulthood. Here we review recent discoveries in the mechanobiology of cardiac valve development and introduce the latest technologies being developed in the zebrafish, including live cell imaging and optical technologies, as well as modeling approaches that are currently transforming this field. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel. Copyright © 2015. Published by Elsevier B.V.

  5. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis

    DEFF Research Database (Denmark)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected fo...

  6. Vibration Analysis and the Accelerometer

    Science.gov (United States)

    Hammer, Paul

    2011-01-01

    Have you ever put your hand on an electric motor or motor-driven electric appliance and felt it vibrate? Ever wonder why it vibrates? What is there about the operation of the motor, or the object to which it is attached, that causes the vibrations? Is there anything "regular" about the vibrations, or are they the result of random causes? In this…

  7. 40 CFR 63.693 - Standards: Closed-vent systems and control devices.

    Science.gov (United States)

    2010-07-01

    ...) Whenever gases or vapors containing HAP are vented through a closed-vent system connected to a control... of such devices include, but are not limited to, a car-seal or a lock-and-key configuration valve. (d...

  8. Mitral Valve Disease: a Comprehensive Review.

    Science.gov (United States)

    Harb, Serge C; Griffin, Brian P

    2017-08-01

    This review aims to provide a comprehensive assessment of mitral valve disease, both mitral stenosis and mitral regurgitation, starting with an overview of the valve anatomy. The advent of three-dimensional imaging has allowed a better representation of the valve anatomy. Rheumatic disease is still the number one cause of mitral stenosis worldwide and percutaneous balloon mitral valvuloplasty remains the therapy of choice when indicated and in anatomically eligible patients. Mitral regurgitation (MR) is classified as primary (i.e., lesion in the mitral apparatus) or secondary (caused by left ventricular geometrical alterations). While surgery, preferably repair, is still the recommended therapy for severe primary MR, percutaneous approaches to repair and/or replace the mitral valve are being extensively investigated. Mitral valve disease is common. A careful understanding of mitral valve anatomy and the disease processes that affect the valve are crucial for providing optimal patient care.

  9. Mitral Valve Repair: The Chordae Tendineae

    Directory of Open Access Journals (Sweden)

    Carlos-A Mestres

    2015-10-01

    Full Text Available Repair of the mitral valve is the treatment of choice for mitral valve regurgitation when the anatomy is favorable. It is well known that mitral valve repair enjoys better clinical and functional results than any other type of valve substitute. This fact is beyond doubt regardless of the etiology of the valve lesion and is of particular importance in degenerative diseases.This review analyzes the most important advances in the knowledge of the anatomy, pathophysiology, and chordal function of the mitral valve as well as the different alternatives in the surgical repair and clinical results of the most prevalent diseases of the mitral valve. An attempt has been made to organize the acquired information available in a practical way.

  10. Metabolite Valves: Dynamic Control of Metabolic Flux for Pathway Engineering

    Science.gov (United States)

    Prather, Kristala

    2015-03-01

    Microbial strains have been successfully engineered to produce a wide variety of chemical compounds, several of which have been commercialized. As new products are targeted for biological synthesis, yield is frequently considered a primary driver towards determining feasibility. Theoretical yields can be calculated, establishing an upper limit on the potential conversion of starting substrates to target compounds. Such yields typically ignore loss of substrate to byproducts, with the assumption that competing reactions can be eliminated, usually by deleting the genes encoding the corresponding enzymes. However, when an enzyme encodes an essential gene, especially one involved in primary metabolism, deletion is not a viable option. Reducing gene expression in a static fashion is possible, but this solution ignores the metabolic demand needed for synthesis of the enzymes required for the desired pathway. We have developed Metabolite valves to address this challenge. The valves are designed to allow high flux through the essential enzyme during an initial period where growth is favored. Following an external perturbation, enzyme activity is then reduced, enabling a higher precursor pool to be diverted towards the pathway of interest. We have designed valves with control at both the transcriptional and post-translational levels. In both cases, key enzymes in glucose metabolism are regulated, and two different compounds are targeted for heterologous production. We have measured increased concentrations of intracellular metabolites once the valve is closed, and have demonstrated that these increased pools lead to increased product yields. These metabolite valves should prove broadly useful for dynamic control of metabolic flux, resulting in improvements in product yields.

  11. Vibrations and Stability

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel

    About this textbook An ideal text for students that ties together classical and modern topics of advanced vibration analysis in an interesting and lucid manner. It provides students with a background in elementary vibrations with the tools necessary for understanding and analyzing more complex...... dynamical phenomena that can be encountered in engineering and scientific practice. It progresses steadily from linear vibration theory over various levels of nonlinearity to bifurcation analysis, global dynamics and chaotic vibrations. It trains the student to analyze simple models, recognize nonlinear...... phenomena and work with advanced tools such as perturbation analysis and bifurcation analysis. Explaining theory in terms of relevant examples from real systems, this book is user-friendly and meets the increasing interest in non-linear dynamics in mechanical/structural engineering and applied mathematics...

  12. Vibration fatigue using modal decomposition

    Science.gov (United States)

    Mršnik, Matjaž; Slavič, Janko; Boltežar, Miha

    2018-01-01

    Vibration-fatigue analysis deals with the material fatigue of flexible structures operating close to natural frequencies. Based on the uniaxial stress response, calculated in the frequency domain, the high-cycle fatigue model using the S-N curve material data and the Palmgren-Miner hypothesis of damage accumulation is applied. The multiaxial criterion is used to obtain the equivalent uniaxial stress response followed by the spectral moment approach to the cycle-amplitude probability density estimation. The vibration-fatigue analysis relates the fatigue analysis in the frequency domain to the structural dynamics. However, once the stress response within a node is obtained, the physical model of the structure dictating that response is discarded and does not propagate through the fatigue-analysis procedure. The structural model can be used to evaluate how specific dynamic properties (e.g., damping, modal shapes) affect the damage intensity. A new approach based on modal decomposition is presented in this research that directly links the fatigue-damage intensity with the dynamic properties of the system. It thus offers a valuable insight into how different modes of vibration contribute to the total damage to the material. A numerical study was performed showing good agreement between results obtained using the newly presented approach with those obtained using the classical method, especially with regards to the distribution of damage intensity and critical point location. The presented approach also offers orders of magnitude faster calculation in comparison with the conventional procedure. Furthermore, it can be applied in a straightforward way to strain experimental modal analysis results, taking advantage of experimentally measured strains.

  13. Concorde Noise-Induced Building Vibrations, Montgomery County, Maryland

    Science.gov (United States)

    Mayes, W. H.; Scholl, H. F.; Stephens, D. G.; Holliday, B. G.; Deloach, R.; Finley, T. D.; Holmes, H. K.; Lewis, R. B.; Lynch, J. W.

    1976-01-01

    A series of studies are reported to assess the noise induced building vibrations associated with Concorde operations. The levels of induced vibration and associated indoor/outdoor noise levels resulting from aircraft and nonaircraft events in selected homes, historic and other buildings near Dulles International Airport were recorded. The building response resulting from aircraft operations was found to be directly proportional to the overall sound pressure level and approximately independent of the aircraft type. The noise levels and, consequently, the response levels were observed to be higher for the Concorde operations than for the CTOL operations. Furthermore, the vibration could be closely reproduced by playing aircraft noise through a loudspeaker system located near the vibration measurement location. Nonaircraft events such as door closing were again observed to result in higher response levels than those induced by aircraft.

  14. Misleading image of mechanical valve leaflet by transesophageal echocardiography.

    Science.gov (United States)

    Orihashi, Kazumasa

    2011-04-01

    Although bileaflet prosthetic valve function is commonly assessed by means of transesophageal echocardiography (TEE) during surgery, the author reports that the leaflet image is not a real image but an artifact. As the depth of the transducer is altered, the leaflet image is gradually skewed in relation to the plane of the prosthetic valve ring. The leaflet-like image consistently overlaps the line that is drawn from the transducer position to the atrial side edge of the leaflet, indicating that this image is caused by reverberations. Three-dimensional TEE shows that the leaflet image is not semilunar but is elongated towards the left ventricle and unusually tilted. As viewed from the ventricular side, the ring image is elongated and forms a cylinder-like image in the left ventricle, and the leaflets appear to be opening and closing at the bottom of this cylinder. Therefore, TEE assessment of leaflets in the open position can be misleading.

  15. Mechanical Prosthetic Valves and Pregnancy: A therapeutic dilemma of anticoagulation

    Directory of Open Access Journals (Sweden)

    Prashanth Panduranga

    2014-10-01

    Full Text Available Choosing the best anticoagulant therapy for a pregnant patient with a mechanical prosthetic valve is controversial and the published international guidelines contain no clear-cut consensus on the best approach. This is due to the fact that there is presently no anticoagulant which can reliably decrease thromboembolic events while avoiding damage to the fetus. Current treatments include either continuing oral warfarin or substituting warfarin for subcutaneous unfractionated heparin or low-molecular-weight heparin (LMWH in the first trimester (6–12 weeks or at any point throughout the pregnancy. However, LMWH, while widely-prescribed, requires close monitoring of the blood anti-factor Xa levels. Unfortunately, facilities for such monitoring are not universally available, such as within hospitals in developing countries. This review evaluates the leading international guidelines concerning anticoagulant therapy in pregnant patients with mechanical prosthetic valves as well as proposing a simplified guideline which may be more relevant to hospitals in this region.

  16. Physiological vortices in the sinuses of Valsalva: An in vitro approach for bio-prosthetic valves.

    Science.gov (United States)

    Toninato, Riccardo; Salmon, Jacob; Susin, Francesca Maria; Ducci, Andrea; Burriesci, Gaetano

    2016-09-06

    The physiological flow dynamics within the Valsalva sinuses, in terms of global and local parameters, are still not fully understood. This study attempts to identify the physiological conditions as closely as possible, and to give an explanation of the different and sometime contradictory results in literature. An in vitro approach was implemented for testing porcine bio-prosthetic valves operating within different aortic root configurations. All tests were performed on a pulse duplicator, under physiological pressure and flow conditions. The fluid dynamics established in the various cases were analysed by means of 2D Particle Image Velocimetry, and related with the achieved hydrodynamic performance. Each configuration is associated with substantially different flow dynamics, which significantly affects the valve performance. The configuration most closely replicating healthy native anatomy was characterised by the best hemodynamic performance, and any mismatch in size and position between the valve and the root produced substantial modification of the fluid dynamics downstream of the valve, hindering the hydrodynamic performance of the system. The worst conditions were observed for a configuration characterised by the total absence of the Valsalva sinuses. This study provides an explanation for the different vortical structures described in the literature downstream of bioprosthetic valves, enlightening the experimental complications in valve testing. Most importantly, the results clearly identify the fluid mechanisms promoted by the Valsalva sinuses to enhance the ejection and closing phases, and this study exposes the importance of an optimal integration of the valve and root, to operate as a single system. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Bleb incarceration following Ahmed valve surgery

    Directory of Open Access Journals (Sweden)

    Gross FJ

    2016-10-01

    Full Text Available Fredric J Gross, Giovanni DiSandro Department of Ophthalmology, Eastern Virginia Medical School, Norfolk, VA, USA Abstract: Globe luxation is a painful and potentially vision-threatening condition in which the globe becomes trapped behind the eyelids requiring physician intervention in the emergency department or eye clinic. On presentation, the patient typically complains of an inability to close their eye, severe foreign body sensation, decreased vision, and significant eye pain. Although most visual symptoms are reversible and primarily result from exposure keratopathy, optic nerve damage, and permanent vision loss can occur from repeat or prolonged episodes of globe luxation. Risk factors include any congenital or acquired conditions that displace the globe anteriorly in the orbit and increased eyelid laxity that allows the globe to prolapse through the lid aperture. Typically, the precipitating event involves eyelid retraction during ophthalmic examination or an event that increases intraorbital pressure such as coughing or sneezing. Once the globe has luxated, the condition is typically worsened by blepharospasm and patients’ attempts to close the eye that worsen the entrapment. In the current case, the patient had a large superotemporal filtering bleb following Ahmed valve surgery for uncontrolled glaucoma. While instilling her glaucoma medication, she retracted her eyelids sufficiently to pull the upper lid over her filtering bleb where it became entrapped causing a similar presentation to globe luxation. Traditional methods of repositioning the globe were unsuccessful. Bleb needling was ultimately required to return the globe to a normal position. Keywords: luxation, globe, glaucoma

  18. Bench-top evaluation of air flow through a valved peelable introducer sheath.

    Science.gov (United States)

    Vesely, Thomas M; Ness, Peter J; Hart, John E

    2005-11-01

    Air embolism is a rare but potentially fatal complication that may occur during the insertion of a central venous catheter. A valved peelable introducer sheath was developed to reduce the likelihood of an air embolus. This study was performed to determine the rate of air flow through this valved introducer sheath under different conditions that may be encountered in a clinical setting. A 16-F-diameter valved peelable introducer sheath was used for all experiments. A bench-top testing system was constructed that consisted of a vacuum source, a mass flow meter, and a digital vacuum gauge. A coupling device with a pneumatic O-ring was used to seal and connect the distal end of the introducer sheath to the testing system. A vacuum of -5 mm Hg was applied to the sealed distal end of the sheath to simulate physiologic conditions. The rate of air flow through the valved sheath was measured under three different conditions; (i) valve open, (ii) valve closed, and (iii) valve open but with the sheath manually pinched. Thirty air flow measurements were performed for each of the three test conditions. When the valve was in the open position, the mean rate of air flow through the introducer sheath was 417.2 mL/sec (range, 415.5-419.7 mL/sec). When the valve was in the closed position, the mean rate of air flow was 0.004 mL/sec (range, 0.000-0.067 mL/sec). When the valve was open but the sheath was manually pinched, the mean rate of air flow through the sheath was 31.7 mL/sec (range, 23.0-38.8 mL/sec). During the 90 testing procedures, the mean vacuum was -5.10 mm Hg (range, -5.00 to -5.45 mm Hg). This bench-top study revealed that a massive amount of air flowed through the open 16-F introducer sheath when it was subjected to a vacuum of -5 mm Hg, a situation that may occur under normal physiologic conditions. The rate of air flow could be decreased by aggressively pinching the sheath but the rate of air flow was still substantial. This study demonstrated that the addition of a

  19. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    Science.gov (United States)

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  20. Contemporary outcomes in reoperative mitral valve surgery.

    Science.gov (United States)

    Mehaffey, Hunter J; Hawkins, Robert B; Schubert, Sarah; Fonner, Clifford; Yarboro, Leora T; Quader, Mohammed; Speir, Alan; Rich, Jeff; Kron, Irving L; Ailawadi, Gorav

    2017-10-05

    Data suggest that redo mitral valve surgery is being performed in increasing numbers, possibly with superior results according to single-centre studies. The purpose of this study is to describe outcomes of redo mitral valve surgery and identify risk-adjusted predictors of poor outcomes. All (11 973) open mitral valve cases were evaluated (2002-2016) from a regional Society of Thoracic Surgery (STS) database. Patients were stratified by primary versus redo mitral valve surgery. Mixed effects logistic regression models including hospital as a random effect were used to identify risk factors for patients undergoing redo mitral valve surgery. Of all mitral valve cases, 1096 (9.7%) had a previous mitral operation. Redo patients had higher rates of valve replacement and preoperative comorbidities resulting in more complications, operative mortalities (11.1%vs6.5%, pmitral valve surgery increased 10% per year and the observed-to-expected ratios (O/E) for operative mortality in redo mitral surgery improved from 1.44 early in the study period to 0.72 in the most recent era. Redo mitral valve surgery accounts for approximately 10% of mitral valve operations and is associated with increased risk and resource utilisation. However, as the volume of redo mitral surgery increases, outcomes have dramatically improved and are now better than predicted. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  2. Bioprosthetic heart valves of the future.

    Science.gov (United States)

    Manji, Rizwan A; Ekser, Burcin; Menkis, Alan H; Cooper, David K C

    2014-01-01

    Glutaraldehyde-fixed bioprosthetic heart valves (GBHVs), derived from pigs or cows, undergo structural valve deterioration (SVD) over time, with calcification and eventual failure. It is generally accepted that SVD is due to chemical processes between glutaraldehyde and free calcium ions in the blood. Valve companies have made significant progress in decreasing SVD from calcification through various valve chemical treatments. However, there are still groups of patients (e.g., children and young adults) that have accelerated SVD of GBHV. Unfortunately, these patients are not ideal patients for valve replacement with mechanical heart valve prostheses as they are at high long-term risk from complications of the mandatory anticoagulation that is required. Thus, there is no "ideal" heart valve replacement for children and young adults. GBHVs represent a form of xenotransplantation, and there is increasing evidence that SVD seen in these valves is at least in part associated with xenograft rejection. We review the evidence that suggests that xenograft rejection of GBHVs is occurring, and that calcification of the valve may be related to this rejection. Furthermore, we review recent research into the transplantation of live porcine organs in non-human primates that may be applicable to GBHVs and consider the potential use of genetically modified pigs as sources of bioprosthetic heart valves. © 2014 John Wiley & Sons A/S.

  3. Effect of Fluid Viscosity on Noise of Bileaflet Prosthetic Heart Valve

    Directory of Open Access Journals (Sweden)

    Vladimir A. Voskoboinick

    2017-10-01

    Full Text Available Background. Numerical simulation and experimental research have been used as powerful tools to understand and predict the behavior and mechanics of the operation of natural heart valves and their prostheses in natural and patho­logical conditions. Such studies help to evaluate the effectiveness of the valves, their design and the results of surgical procedures, to diagnose healthy and impaired function of the heart valves. There is an actual problem in creating more reliable methods and tools for the operation diagnostics of mechanical heart valves. Objective. The aim of the research is to investigate the effect of fluid viscosity on the hydroacoustic characteristics of jets that flow from a semi-closed and open mechanical bileaflet heart valve. To study the possibility of using hydro­acoustic measuring instruments as diagnostic equipment for determining the working conditions of the bileaflet pro­sthe­tic heart valve. Methods. The experimental research was carried out by means of hydroacoustic measurements of the hydrodynamic noise in the near wake of the side and central jets of the glycerin solution and the pure water flow downstream of the prosthetic bileaflet heart valve. Results. The effect of fluid viscosity on the hydroacoustic characteristics of the jets that flow from a semi-closed and open mechanical bileaflet heart valve has been experimentally determined. Integral and spectral characteristics of the hydrodynamic noise of jets of the glycerin solution and the pure water flow downstream of the bileaflet mitral heart valve for different fluid rate were detected. Conclusions. In the stream conditions of pure water, the integral characteristics of the pressure field are lower than in stream conditions of the aqueous glycerin solution. As the glycerin concentration in the solution increases, increase average pressures and especially RMS pressure fluctuations. The spectral levels of the hydrodynamic noise in the near wake of the side

  4. Effect of a combined anti-thrombotic therapy of thrombosis on prosthetic heart valves.

    Science.gov (United States)

    Wei, Wei; Dong, Taiming; Zheng, Zhichao; Huang, Shuping

    2015-03-01

    for two cases of mild subcutaneous ecchymoses. The combined anti-thrombotic therapy based on clopidogrel and warfarin is a feasible treatment for thrombosis on prosthetic heart valves under a close monitoring.

  5. Injetor multicanal com válvulas de estrangulamento para análise em fluxo Pinch valve injector for flow analysis

    Directory of Open Access Journals (Sweden)

    Fabiano S. Palgrossi

    2001-10-01

    Full Text Available An important component for the automation of flow injection analysis (FIA systems is the sample injection valve. A simple and inexpensive commutator with 16 pinch valves (8 normally open and 8 closed was developed and configured as a multichannel injection valve. It is activated by a single solenoid of 3 Kgf, powered by a pulsed driver circuit, controlled by a microcomputer or a switch. FIA with spectrophometric detection of potassium dichromate solution was used for the evaluation of the new injection valve and its comparison with other valves, for sample loops of 50, 100, 200, 300 and 500 muL. The repeatability was favorable (RSD 1.0% for 15 injections at each loop volume compared to a manual injector, an electropneumatic injector and an injector configured with three mini solenoid valves (RSD 1.1, 1.3 and 1.0%, respectively, for15 injections at each loop volume.

  6. Flow Characteristics of Butterfly Valve by PIV and CFD

    Science.gov (United States)

    Kim, S. W.; Kim, J. H.; Choi, Y. D.; Lee, Y. H.

    Butterfly valves are widely used as on-off and control valves for industrial process. The importance of butterfly valves as control valves has been increasing because the pressure loss is smaller than other types of valves and compactness is very desirable for installation. These features are desirable for saving energy and high efficiency of instruments.

  7. Mechanical valves in the pulmonary position : An international retrospective analysis

    NARCIS (Netherlands)

    Pragt, Hanna; van Melle, Joost P.; Javadikasgari, Hoda; Seo, Dong Man; Stulak, John M.; Knez, Igor; Hoerer, Juergen; Munoz-Guijosa, Christian; Dehaki, Mahyar G.; Shin, Hong Ju; Dearani, Joseph A.; Dehaki, Maziar G.; Pieper, Petronella G.; Eulenburg, Christine; Dos, Laura; Ebels, Tjark

    2017-01-01

    Objective: Life expectancy of patients with congenital heart disease has improved over the past decades, increasing the need for a durable pulmonary prosthetic valve. Biological valves in various forms have become the valve of choice for pulmonary valve replacement (PVR), but structural valve

  8. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    Science.gov (United States)

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR.

  9. Aerococcus viridans Native Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Wenwan Zhou

    2013-01-01

    Full Text Available Aerococcus viridans is an infrequent human pathogen and few cases of infective endocarditis have been reported. A case involving a 69-year-old man with colon cancer and hemicolectomy 14 years previously, without recurrence, is reported. A diagnosis of native mitral valve endocarditis was established on the basis of clinical presentation, characteristic echocardiographic findings and pathological specimen examination after urgent valve replacement. A viridans endocarditis appears to be particularly virulent, requiring a surgical approach in four of 10 cases reported and death in one of nine. Given the aggressive nature of A viridans endocarditis and the variable time to diagnosis (a few days to seven months, prompt recognition of symptoms and echocardiography, in addition to blood cultures, should be performed when symptoms persist.

  10. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  11. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  12. 3D Printed Multimaterial Microfluidic Valve.

    Science.gov (United States)

    Keating, Steven J; Gariboldi, Maria Isabella; Patrick, William G; Sharma, Sunanda; Kong, David S; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  13. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    BACKGROUND: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), inclu...... population. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01057173....

  14. Postoperative anticoagulation in patients with mechanical heart valves following surgical treatment of subdural hematomas.

    Science.gov (United States)

    Amin, Anubhav G; Ng, Julie; Hsu, Wesley; Pradilla, Gustavo; Raza, Shaan; Quinones-Hinojosa, Alfredo; Lim, Michael

    2013-08-01

    Thromboembolic events and anticoagulation-associated bleeding events represent frequent complications following cardiac mechanical valve replacement. Management guidelines regarding the timing for resuming anticoagulation therapy following a surgically treated subdural hematoma (SDH) in patients with mechanical valves remains to be determined. To determine optimal anticoagulation management in patients with mechanical heart valves following treatment of SDH. Outcomes were retrospectively reviewed for 12 patients on anticoagulation therapy for thromboembolic prophylaxis for mechanical cardiac valves who underwent surgical intervention for a SDH at the Johns Hopkins Hospital between 1995 and 2010. The mean age at admission was 71 years. All patients had St. Jude's mechanical heart valves and were receiving anticoagulation therapy. All patients had their anticoagulation reversed with vitamin K and fresh frozen plasma and underwent surgical evacuation. Anticoagulation was withheld for a mean of 14 days upon admission and a mean of 9 days postoperatively. The average length of stay was 19 days. No deaths or thromboembolic events occurred during the hospitalization. Average follow-up time was 50 months, during which two patients had a recurrent SDH. No other associated morbidities occurred during follow-up. Interruptions in anticoagulation therapy for up to 3 weeks pose minimal thromboembolic risk in patients with mechanical heart valves. Close follow-up after discharge is highly recommended, as recurrent hemorrhages can occur several weeks after the resumption of anticoagulation.

  15. Simplified surgical-hybrid Melody® valve implantation for paediatric mitral valve disease

    OpenAIRE

    Hofmann, Michael; Dave, Hitendu; Hübler, Michael; Kretschmar, Oliver

    2017-01-01

    Children suffering from left atrioventricular valve (LAVV) disease not amenable to repair represent a significant challenge. The results of surgical reconstruction are not optimal. Valve replacement as an alternative is associated with poor results. The surgical-hybrid approach with implantation of a stented biological valve (bovine jugular vein graft, Melody® valve) seems to represent a new therapeutic option. Here we demonstrate our case, the consideration and the approach to extreme clinic...

  16. Propellant actuated nuclear reactor steam depressurization valve

    Science.gov (United States)

    Ehrke, Alan C.; Knepp, John B.; Skoda, George I.

    1992-01-01

    A nuclear fission reactor combined with a propellant actuated depressurization and/or water injection valve is disclosed. The depressurization valve releases pressure from a water cooled, steam producing nuclear reactor when required to insure the safety of the reactor. Depressurization of the reactor pressure vessel enables gravity feeding of supplementary coolant water through the water injection valve to the reactor pressure vessel to prevent damage to the fuel core.

  17. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  18. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  19. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  20. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  1. Percutaneous approaches to mitral valve disease

    National Research Council Canada - National Science Library

    Fassa, A-A; Himbert, D; Brochet, E; Bouleti, C; Vahanian, A

    2015-01-01

    Percutaneous approaches to mitral valve disease consist in modifications of existing surgical techniques, aiming to replicate the favourable outcomes of surgery, with less procedure-related risk, due...

  2. Hammock mitral valve: A rare case report

    Directory of Open Access Journals (Sweden)

    Veeresh F. Manvi

    2014-01-01

    Full Text Available Congenital mitral stenosis is a relatively rare disorder comprising 0.2% of all congenital heart defects. Hammock mitral valve producing severe mitral stenosis is a rare variant of congenital mitral stenosis. We report a 2-year-old boy who had hammock mitral valve producing severe mitral stenosis with severe pulmonary artery hypertension. He underwent successful surgical repair. Post-surgery, the mitral valve opening was adequate without residual stenosis or regurgitation. Pulmonary artery pressure had normalized. Follow-up data showed he had significant clinical and echocardiography improvement. This is the first reported case of successful surgical repair done for hammock mitral valve from our institute.

  3. Stentless aortic valve replacement: an update

    Directory of Open Access Journals (Sweden)

    Kobayashi J

    2011-06-01

    Full Text Available Junjiro KobayashiDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, Osaka, JapanAbstract: Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient–prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose of this review is to provide a current overview of stentless valves in the aortic position. Retrospective and prospective randomized controlled studies showed similar operative mortality and morbidity in stented and stentless aortic valve replacement (AVR, though stentless AVR required longer cross-clamp and cardiopulmonary bypass time. Several cohort studies showed improved survival after stentless AVR, probably due to better hemodynamic performance and earlier left ventricular (LV mass regression compared with stented AVR. However, there was a bias of operation age and nonrandomization. A randomized trial supported an improved 8-year survival of patients with the Freestyle or Toronto valves compared with Carpentier–Edwards porcine valves. On the contrary, another randomized study did not show improved clinical outcomes up to 12 years. Freedom from reoperation at 12 years in Toronto stentless porcine valves ranged from 69% to 75%, which is much lower than for Carpentier–Edwards Perimount valves. Cusp tear with consequent aortic regurgitation was the most common cause of structural valve deterioration. Cryolife O'Brien valves also have shorter durability compared with stent valves. Actuarial freedom from reoperation was 44% at 10 years. Early prosthetic valve failure was also reported in patients who underwent root replacement with Shelhigh stentless composite grafts. There was no level I or IIa evidence of more effective orifice

  4. Pump arrangement Comprising a Savety Valve

    OpenAIRE

    Richter, M.; Kruckow, J.

    2009-01-01

    A pump arrangement comprises a pump (20) having a pump inlet (22) and a pump outlet (24), which are designed to pump a fluid from the pump inlet to the pump outlet, and it further comprises a safety valve (40), which is disposed between the pump outlet (24) and an outlet (48) of the pump arrangement and comprises a valve set (42) and a valve cover (44). The valve seat, the pump outlet, and the pump inlet are structured in a first surface of a first single-piece part (14) of the pump arrangeme...

  5. Fracturing a dysfunctional Edwards Perimount bioprosthetic valve to facilitate percutaneous valve-in-valve placement of SAPIEN 3 valve with modified delivery system.

    Science.gov (United States)

    Shahanavaz, Shabana; Rockefeller, Toby; Nicolas, Ramzi; Balzer, David

    2017-10-10

    Pulmonary valve replacement via surgical implantation of a bioprosthetic valve (BPV) is a well-established treatment for patients with dysfunctional RV outflow tracts. BPVs are prone to structural deterioration, and will eventually require replacement. Recently, percutaneous valve-in-valve (VIV) placement of transcatheter valves has established itself as a safe and effective alternative to surgical revision. Unfortunately, VIV therapy is inherently limited by the inner diameter of the BPV, which restricts the number of eligible patients. Other centers have reported on the feasibility of cracking certain BPVs with ultra high-pressure balloons in bench testing. We now report cracking an Edwards Perimount BPV in the pulmonary position to facilitate VIV placement of an Edwards SAPIEN 3. The ability to crack the Perimount valve allowed placement of a larger valve than previously considered and minimized the final valve gradient. In an effort to avoid the morbidity and mortality of surgical pulmonary valve replacement, this new strategy will expand the number of patients eligible for percutaneous VIV therapy. © 2017 Wiley Periodicals, Inc.

  6. A new technique for vascular access management in transcatheter aortic valve implantation.

    Science.gov (United States)

    Sharp, Andrew S P; Michev, Iassen; Maisano, Francesco; Taramasso, Maurizio; Godino, Cosmo; Latib, Azeem; Denti, Paulo; Dorigo, Enrica; Giacomini, Andrea; Iaci, Giuseppe; Manca, Mario; Ielasi, Alfonso; Montorfano, Matteo; Alfieri, Ottavio; Colombo, Antonio

    2010-04-01

    To describe results from a novel percutaneous technique designed to minimize the risk of hemorrhage in the event of a major complication during transcatheter aortic valve implantation. Vascular access management is a major challenge in transfemoral TAVI due to the large introducer sheathes required. Fifty-two pts underwent TAVI between November 2007 and March 2009. Of these, 37 received an Edwards-Sapien Valve (23 mm valve: 17/37; 26 mm valve: 20/37) whilst 15 patients received a CoreValve (26 mm valve: 6/15; 29 mm valve: 9/15). Using a crossover technique, the opposing femoral artery was cannulated with a 7Fr long sheath. This allowed contralateral passage of a balloon and inflation in the proximal iliac. The sheath was then removed and Prostar sutures tied in a dry field. Balloon optimization of the puncture site was performed as required. In three subjects, elective surgical repair was undertaken due to excessive femoral arterial calcification. In the remaining 49, the crossover technique was employed and closed with two Prostar devices (Edwards-Sapien) or one (CoreValve). There were serious "on-table" complications in seven patients, six due to the large introducer sheathes used in the TAVI procedure-iliac avulsion, two iliac dissections, iliac perforation, common femoral perforation and scrotal hematoma. All were repaired safely by combined surgical and endovascular techniques, using the crossover technique to ensure patient stability. All made a good recovery and were independently ambulant at discharge. Using crossover balloon inflation as an adjunct to Prostar closure may be helpful for managing TAVI vascular access sites. (c) 2009 Wiley-Liss, Inc.

  7. Aortic Calcification: An Early Sign of Heart Valve Problems?

    Science.gov (United States)

    ... the aortic valve — a condition called aortic valve stenosis. Aortic valve calcification may be an early sign ... have any other heart disease symptoms. Calcification and stenosis generally affects people older than age 65. When ...

  8. 40 CFR 63.175 - Quality improvement program for valves.

    Science.gov (United States)

    2010-07-01

    ... (e.g., ball, gate, check); valve manufacturer; valve design (e.g., external stem or actuating... categories, or classes, of valves as needed to distinguish among operating conditions and services associated...

  9. Vibrational spectroscopy of resveratrol

    Science.gov (United States)

    Billes, Ferenc; Mohammed-Ziegler, Ildikó; Mikosch, Hans; Tyihák, Ernő

    2007-11-01

    In this article the authors deal with the experimental and theoretical interpretation of the vibrational spectra of trans-resveratrol (3,5,4'-trihydroxy- trans-stilbene) of diverse beneficial biological activity. Infrared and Raman spectra of the compound were recorded; density functional calculations were carried out resulting in the optimized geometry and several properties of the molecule. Based on the calculated force constants, a normal coordinate analysis yielded the character of the vibrational modes and the assignment of the measured spectral bands.

  10. Man-Induced Vibrations

    DEFF Research Database (Denmark)

    Jönsson, Jeppe; Hansen, Lars Pilegaard

    1994-01-01

    concerned with spectator-induced vertical vibrations on grandstands. The idea is to use impulse response analysis and base the load description on the load impulse. If the method is feasable, it could be used in connection with the formulation of requirements in building codes. During the last two decades...... work has been done on the measurement of the exact load functions and related reponse analysis. A recent work using a spectral description has been performed by Per-Erik Erikson and includes a good literature survey. Bachmann and Ammann give a good overview of vibrations caused by human activity. Other...

  11. Vibrations and waves

    CERN Document Server

    Kaliski, S

    2013-01-01

    This book gives a comprehensive overview of wave phenomena in different media with interacting mechanical, electromagnetic and other fields. Equations describing wave propagation in linear and non-linear elastic media are followed by equations of rheological models, models with internal rotational degrees of freedom and non-local interactions. Equations for coupled fields: thermal, elastic, electromagnetic, piezoelectric, and magneto-spin with adequate boundary conditions are also included. Together with its companion volume Vibrations and Waves. Part A: Vibrations this work provides a wealth

  12. Endobronchial valves in the management of bronchial fistulae caused by bronchopulmonary aspergillosis.

    Science.gov (United States)

    Williams, Rhys; Krishnadas, Rakesh; Patel, Bipen; Jarad, Nabil

    2015-12-01

    Following an aggressive episode of bronchopulmonary aspergillosis, a 54-year-old man developed a symptomatic air leak via a tunnel between the left upper lobe and an extra chest wall cavity. Following the failure of several surgical procedures to close the tunnel, endobronchial valves normally used in management of emphysema were used to successfully treat the air leak. 2015 BMJ Publishing Group Ltd.

  13. Numerical Research on Flow Characteristics around a Hydraulic Turbine Runner at Small Opening of Cylindrical Valve

    Directory of Open Access Journals (Sweden)

    Zhenwei Mo

    2016-01-01

    Full Text Available We use the continuity equation and the Reynolds averaged Navier-Stokes equations to study the flow-pattern characteristics around a turbine runner for the small-opening cylindrical valve of a hydraulic turbine. For closure, we adopt the renormalization-group k-ε two-equation turbulence model and use the computational fluid dynamics (CFD software FLUENT to numerically simulate the three-dimensional unsteady turbulent flow through the entire passage of the hydraulic turbine. The results show that a low-pressure zone develops around the runner blades when the cylindrical valve is closed in a small opening; cavitation occurs at the blades, and a vortex appears at the outlet of the runner. As the cylindrical valve is gradually closed, the flow velocity over the runner area increases, and the pressure gradient becomes more significant as the discharge decreases. In addition, the fluid flow velocity is relatively high between the lower end of the cylindrical valve and the base, so that a high-velocity jet is easily induced. The calculation and analysis provide a theoretical basis for improving the performance of cylindrical-valve operating systems.

  14. Smart Electric Valve Controller Based on All Digital Phase-Locked Loop

    Directory of Open Access Journals (Sweden)

    Li Xiaoling

    2014-02-01

    Full Text Available Electric valve has been applied to various occasions and domains. In some adverse environments where such defects of traditional control system as low efficiency and poor safety have been exposed, optical encoder is adopted to detect the motor’s angular speed and displacement and ADPLL is used for generating control logic, so as to regulate switching frequency and duty ratio of pulse wavelength modulation (PWM, alter the motor’s input voltage and current and achieve the open and close control of Electric valve. The system can automatically regulate the rotating speed and the dragging torque of motor based on the open and close position, rotating speed and torque of the valve to make sure that the motor can achieve the best rotating speed and torque. The results of the test by motor 90ZY24-200 prove that the system has prompt response, high accuracy, little harmonic and ripple range; it can also automatically adapt to the torque alteration to realize the protective function of direct current (DC motor. Electric valve control based on ADPLL can not only realize functions of the whole system, but also enjoys a stable and reliable performance. It can reduce the harmonic and ripple, and help the whole system achieve real-time remote control, data collection and transmission, and display the motor torque in LED, so as to control the valve flow stably and accurately through DC motor.

  15. Valve movement response of the freshwater clam Corbicula fluminea following exposure to waterborne arsenic.

    Science.gov (United States)

    Liao, Chung-Min; Jau, Sheng-Feng; Lin, Chieh-Ming; Jou, Li-John; Liu, Chen-Wuing; Liao, Vivian Hsiu-Chuan; Chang, Fi-John

    2009-07-01

    We developed an inductance-based valvometry technique as a detection system to measure the valve daily activity in freshwater clam Corbicula fluminea in response to waterborne arsenic. Our findings reveal that C. fluminea experiences a valve opening in the absence of arsenic predominantly in the morning hours (03:00-08:00) with a mean daily opening/closing period of 21.32 (95% CI: 20.58-22.05) h. Amplification of daily activity occurred in the presence of arsenic. Behavioral toxicity assays revealed arsenic detection thresholds of 0.60 (95% CI: 0.53-0.66) mg l(-1) and 0.35 (95% CI: 0.30-0.40) mg l(-1) for response times of 60 and 300 min, respectively. The proposed valve daily activity model was linked with response time-specific Hill dose-response functions to predict valve opening/closing behavior in response to arsenic. The predictive capabilities were verified satisfactory with the measurements. Our results implicate a biomonitoring system by valve daily activity in C. fluminea to identify safe water uses in areas with elevated arsenic.

  16. Heterogeneous Dynamics of Coupled Vibrations

    NARCIS (Netherlands)

    Cringus, Dan; Jansen, Thomas I. C.; Pshenichnikov, Maxim S.; Schoenlein, RW; Corkum, P; DeSilvestri, S; Nelson, KA; Riedle, E

    2009-01-01

    Frequency-dependent dynamics of coupled stretch vibrations of a water molecule are revealed by 2D IR correlation spectroscopy. These are caused by non-Gaussian fluctuations of the environment around the individual OH stretch vibrations.

  17. Cause Analysis of Pressure Plate Breakage of Valve Limit Switch in Turbine Bypass System of Nuclear Power Plant

    Science.gov (United States)

    Li, Nan; Wang, Ming chang; Guan, Jian jun; Li, Guo dong

    2017-07-01

    The limit switch plates of nuclear power plant unit 1 in the turbine bypass system valve are finding multiple fractures. On the basis of metallographic analysis and vibration analysis, the stress state of the pressure plate is simulated and calculated. The results show that there are some creases in the original plate of the limit switch and the installation error of the pressure plate is the main reason for the break.

  18. Vibration-free stirling cryocooler for high definition microscopy

    Science.gov (United States)

    Riabzev, S. V.; Veprik, A. M.; Vilenchik, H. S.; Pundak, N.; Castiel, E.

    2009-12-01

    The normal operation of high definition Scanning Electronic and Helium Ion microscope tools often relies on maintaining particular components at cryogenic temperatures. This has traditionally been accomplished by using liquid coolants such as liquid Nitrogen. This inherently limits the useful temperature range to above 77 K, produces various operational hazards and typically involves elevated ownership costs, inconvenient logistics and maintenance. Mechanical coolers, over-performing the above traditional method and capable of delivering required (even below 77 K) cooling to the above cooled components, have been well-known elsewhere for many years, but their typical drawbacks, such as high purchasing cost, cooler size, low reliability and high power consumption have so far prevented their wide-spreading. Additional critical drawback is inevitable degradation of imagery performance originated from the wideband vibration export as typical for the operation of the mechanical cooler incorporating numerous movable components. Recent advances in the development of reliable, compact, reasonably priced and dynamically quiet linear cryogenic coolers gave rise to so-called "dry cooling" technologies aimed at eventually replacing the traditional use of outdated liquid Nitrogen cooling facilities. Although much improved these newer cryogenic coolers still produce relatively high vibration export which makes them incompatible with modern high definition microscopy tools. This has motivated further research activity towards developing a vibration free closed-cycle mechanical cryocooler. The authors have successfully adapted the standard low vibration Stirling cryogenic refrigerator (Ricor model K535-LV) delivering 5 W@40 K heat lift for use in vibration-sensitive high definition microscopy. This has been achieved by using passive mechanical counterbalancing of the main portion of the low frequency vibration export in combination with an active feed-forward multi

  19. On the natural small vibrations of dislocation in an isotropic medium

    Science.gov (United States)

    Bataronov, I. L.; Dezhin, V. V.

    2017-12-01

    The equation for the natural bending vibrations of an infinite dislocation is written. The long-wavelength limit is considered. The orientation dependence of the vibrational spectrum has been studied. Solutions for two cases (the bending wave velocity along the dislocation line is not equal to the speed of sound waves and the bending wave velocity along the dislocation line is close to the speed of sound waves) are obtained. Local and quasilocal branches of edge and screw dislocations vibrations are found.

  20. Water hammer analysis. Dynamic simulation model check valve piston; Analisis del golpe de airete. Modelo de simulacion dinamica de valvula de retencion piston

    Energy Technology Data Exchange (ETDEWEB)

    Royo, B.; Valdes, R.

    2012-11-01

    This report contains the description and the results of the dynamic simulation model that has been developed to predict the behaviour of one of our lift check valve design. The aim of the model is not only to simulate the closing process of the valve and to product the magnitude of the water hammer effect that may appear immediately after the valve closing, but also to simulate several design version until obtain the optimum which further minimizes such effect. the input data used for this study ensure reliable results since they represent a real system. (Author)

  1. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  2. Composite Struts Would Damp Vibrations

    Science.gov (United States)

    Dolgin, Benjamin P.

    1991-01-01

    New design of composite-material (fiber/matrix laminate) struts increases damping of longitudinal vibrations without decreasing longitudinal stiffness or increasing weight significantly. Plies with opposing chevron patterns of fibers convert longitudinal vibrational stresses into shear stresses in intermediate viscoelastic layer, which dissipate vibrational energy. Composite strut stronger than aluminum strut of same weight and stiffness.

  3. A study of fluid flow and combustion with variable valve timing

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, F.

    1998-10-01

    The effects of variable valve timing (VVT) were examined by in-cylinder Laser Doppler Velocimetry flow measurements and heat-release calculations. A single-cylinder Volvo B5254 engine was used for all experiments and the valve timing was altered by phasing or exchanging the camshaft. Special cam lobes were developed for simulation of throttle-less operation. With the standard double camshaft, a tumbling flow was generated and with valve deactivation, a swirling flow was generated. The turbulence was increased with valve deactivation. This increased the combustion rate making lean burn possible. The standard camshaft with inlet valve deactivation and late cam phasing had a faster combustion at {lambda} = 1.8 than the standard camshaft with normal cam phasing at {lambda} = 1.0. Early and late inlet valve closing was used for enabling throttle-less operation. Early inlet valve closing (EIVC) generated a very slow tumble with low turbulence. Late inlet valve closing generated both very high and low turbulence. The net indicated efficiency was improved with up to 10%. Some reduction was observed for the gross indicated efficiency, due to a too large reduction in effective compression ratio. A very stable combustion was obtained for EIVC with gasoline, possibly due to a sheering flow over the inlet valves resulting in improved fuel-air preparation. Wavelet analysis was used for dividing LDV flow measurements into time and frequency resolved information. The technique rendered the same flow results as the moving window technique, but with a separation of the turbulence into different frequencies. The choice of wavelet was shown not to be crucial. The frequency resolved turbulence was studied for tumble and swirl. A tumbling flow had a larger transfer of energy from low frequency turbulence into high frequency turbulence than a swirling flow. This is caused by the tumble breakdown. A correlation against heat-release indicated that high frequency turbulence have a larger

  4. Ship Vibration Design Guide

    Science.gov (United States)

    1989-07-01

    Frachtschiffen," Werft Reederie Hafen, 1925. 4-21 Noonan, E. F. "Vibration Considerations for 120,000 CM LNG Ships," NKF: Preliminary Report No. 7107, 25...Ship Response to Ice - A Second Season by C. Daley, J. W. St. John, R. Brown, J. Meyer , and I. Glen 1990 SSC-340 Ice Forces and Ship Response to Ice

  5. Compact Vibration Damper

    Science.gov (United States)

    Ivanco, Thomas G. (Inventor)

    2014-01-01

    A vibration damper includes a rigid base with a mass coupled thereto for linear movement thereon. Springs coupled to the mass compress in response to the linear movement along either of two opposing directions. A converter coupled to the mass converts the linear movement to a corresponding rotational movement. A rotary damper coupled to the converter damps the rotational movement.

  6. Vibrations and Eigenvalues

    Indian Academy of Sciences (India)

    The vibrating string problem is the source of much mathematicsand physics. This article describes Lagrange's formulationof a discretised version of the problem and its solution.This is also the first instance of an eigenvalue problem. Author Affiliations. Rajendra Bhatia1. Ashoka University, Rai, Haryana 131 029, India.

  7. Vibration Sensitive Keystroke Analysis

    NARCIS (Netherlands)

    Lopatka, M.; Peetz, M.-H.; van Erp, M.; Stehouwer, H.; van Zaanen, M.

    2009-01-01

    We present a novel method for performing non-invasive biometric analysis on habitual keystroke patterns using a vibration-based feature space. With the increasing availability of 3-D accelerometer chips in laptop computers, conventional methods using time vectors may be augmented using a distinct

  8. Attenuation of cryocooler induced vibration in spaceborne infrared payloads

    Science.gov (United States)

    Veprik, A.; Twitto, A.

    2014-01-01

    Recent advancement of operational responsive space programs calls for a development of compact, reliable, low power and vibration free cryogenic cooling for sophisticated infrared payloads. The refrigeration in a typical closed cycle split Stirling linear cryocooler is achieved by a cyclic compression and expansion of a gaseous working agent due to a synchronized reciprocation of electro-dynamically and pneumatically actuated compressor and expander pistons. Attenuation of the cryocooler induced vibration usually relies on the concept of actively assisted momentum cancellation. In a typical dual-piston compressor this objective is achieved by actively synchronizing the motion of oppositely moving piston assemblies; a typical single-piston expander may be counterbalanced by a motorized counter-balancer. The above approach produces complexity, weight, size, high incurred costs and affects reliability. The authors analyze the case of passive attenuation the vibration export induced by the split Stirling linear cryocooler comprised of inline mounted single-piston compressor and expander. Placement of all the moving components onto a common axis results in a single axis consolidation of vibration export and enables use of single tuned dynamic absorber and low frequency vibration mount. From theoretical analysis and full-scale testing, the performance of such vibration protection arrangement is similar to known systems of active vibration cancellation.

  9. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    -annular mechanical prostheses (CarboMedics, Inc., Arvada, CO, USA) at two institutions. Size frequency distribution was compared to published series, and to the manufacturer's US registry. The ventriculoaortic junction (VAJ) size was available in 234 patients, and compared to the size of the Top Hat valve implanted......BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...... is less than that of a normal valve. It is suggested that the ability to implant Top Hat valves having greater size, relative to standard intra-annular valves, may currently be under-utilized. Further, there has been some concern that Top Hat implantation can cause obstruction of the coronary ostia...

  10. Cylinder valve packing nut studies

    Energy Technology Data Exchange (ETDEWEB)

    Blue, S.C. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    The design, manufacture, and use of cylinder valve packing nuts have been studied to improve their resistance to failure from stress corrosion cracking. Stress frozen photoelastic models have been analyzed to measure the stress concentrations at observed points of failure. The load effects induced by assembly torque and thermal expansion of stem packing were observed by strain gaging nuts. The effects of finishing operations and heat treatment were studied by the strain gage hole boring and X-ray methods. Modifications of manufacturing and operation practices are reducing the frequency of stress corrosion failures.

  11. The Heimlich Valve for Pleural Cavity Drainage

    African Journals Online (AJOL)

    The valve drains into a plastic bag that can be held at any level, allowing the patient to be ambulatory by carrying the bag. The construction and function of the valve is easily understood by medical and nursing staff. It is pre sterilized, stored in a sterile package, and readily utilized on emergency vehicles and in the operating.

  12. Numerical Analysis of Large Diameter Butterfly Valve

    Science.gov (United States)

    Youngchul, Park; Xueguan, Song

    In this paper, a butterfly valve with the diameter of 1,800 mm was studied. Three-dimensional numerical technique by using commercial code CFX were conducted to observe the flow patterns and to measure flow coefficient, hydrodynamic torque coefficient and so on, when the large butterfly valve operated with various angles and uniform incoming velocity.

  13. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    She delivered a normal baby uneventfully in follow up at full term of pregnancy with no complications. Fibrinolytic therapy for mechanical valve thrombosis is a reasonable alternative to surgery in first trimester of pregnancy. KEY WORDS: Prosthetic valve thrombosis; Echocardiography; Streptokinase;. Thrombolysis; Fetus.

  14. Sealing a Loosely Fitting Valve Assembly

    Science.gov (United States)

    Goff, L.; Tellier, G.

    1986-01-01

    Double-ring seal avoids expense of remachining or redesigning valve parts. Mating fittings on valve sealed by pair of rings - one O-ring and backup ring. Backup ring fills relatively large gap between parts. Prevents softer O-ring from being pushed into and through gap.

  15. High Temperature Resistant Exhaust Valve Spindle

    DEFF Research Database (Denmark)

    Bihlet, Uffe Ditlev

    of the engine, new high temperature alloys are required for a specific engine component, the exhaust valve spindle. Two alloys are used for an exhaust valve spindle; one for the bottom of the spindle, and one for the spindle seat. Being placed in the exhaust gas stream, combustion products such as V2O5 and Na2...

  16. Mitral valve disease--morphology and mechanisms.

    Science.gov (United States)

    Levine, Robert A; Hagége, Albert A; Judge, Daniel P; Padala, Muralidhar; Dal-Bianco, Jacob P; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H; Clusel, Catherine; Delling, Francesca N; Dietz, Harry C; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D; Jensen, Morten O; Jeunemaitre, Xavier P; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R; Mérot, Jean; Messas, Emmanuel; Milan, David P; Neri, Tui; Norris, Russell A; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A; Song, Jae-Kwan; Yacoub, Magdi H

    2015-12-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but--even in adult life--remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular-ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease.

  17. Mitral valve disease—morphology and mechanisms

    Science.gov (United States)

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  18. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    , most of these transcatheter mitral valve interventions are still in their early clinical or preclinical development phase. Challenges arising from the complex anatomy of the mitral valve and the interplay of the mitral apparatus with the left ventricle (LV) have contributed to a more difficult...

  19. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    system, most of these transcatheter mitral valve interventions are still in their early clinical or preclinical development phase. Challenges arising from the complex anatomy of the mitral valve and the interplay of the mitral apparatus with the left ventricle (LV) have contributed to a more difficult...

  20. Device at valves. Anordning vid ventiler

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, M.; Hedlund, P.O.

    1990-07-02

    The invention is intended to be utilized in pipes and at valves where there are risks for accumulation of oxyhydrogen gas. In or at the pipe/valve is located a body of recombining material such as platinum or other platinum metals or its alloys in order to recombine oxyhydrogen gas. (L.F.).

  1. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...

  2. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  3. Heart Valve Disease among Patients with Hyperprolactinaemia

    DEFF Research Database (Denmark)

    Steffensen, Charlotte; Maegbaek, Merete Lund; Laurberg, Peter

    2012-01-01

    Increased risk of heart valve disease during treatment with certain dopamine agonists, such as cabergoline, has been observed in patients with Parkinson's disease. The same compound is used to treat hyperprolactinemia, but it is unknown whether this also associates with heart valve disease....

  4. Mitral valve repair in acquired dextrocardia.

    Science.gov (United States)

    Elmistekawy, Elsayed; Chan, Vincent; Hynes, Mark; Mesana, Thierry

    2015-10-01

    Surgical correction of valvular heart disease in patients with dextrocardia is extremely rare. We report a surgical case of mitral valve repair in a patient with acquired dextrocardia. Successful mitral valve repair was performed through a right lateral thoracotomy. We describe our surgical strategy and summarize the literature. © The Author(s) 2014.

  5. Universality in the dynamical properties of seismic vibrations

    Science.gov (United States)

    Chatterjee, Soumya; Barat, P.; Mukherjee, Indranil

    2018-02-01

    We have studied the statistical properties of the observed magnitudes of seismic vibration data in discrete time in an attempt to understand the underlying complex dynamical processes. The observed magnitude data are taken from six different geographical locations. All possible magnitudes are considered in the analysis including catastrophic vibrations, foreshocks, aftershocks and commonplace daily vibrations. The probability distribution functions of these data sets obey scaling law and display a certain universality characteristic. To investigate the universality features in the observed data generated by a complex process, we applied Random Matrix Theory (RMT) in the framework of Gaussian Orthogonal Ensemble (GOE). For all these six places the observed data show a close fit with the predictions of RMT. This reinforces the idea of universality in the dynamical processes generating seismic vibrations.

  6. Magnetic circuit modifications in resonant vibration harvesters

    Science.gov (United States)

    Szabo, Zoltan; Fiala, Pavel; Dohnal, Premysl

    2018-01-01

    The paper discusses the conclusions obtained from a research centered on a vibration-powered milli- or micro generator (MG) operating as a harvester to yield the maximum amount of energy transferred by the vibration of an independent system. The investigation expands on the results proposed within papers that theoretically define the properties characterizing the basic configurations of a generator based on applied Faraday's law of induction. We compared two basic principles of circuit closing in a magnetic circuit that, fully or partially, utilizes a ferromagnetic material, and a large number of generator design solutions were examined and tested. In the given context, the article brings a compact survey of the rules facilitating energy transformation and the designing of harvesters.

  7. Low cost valves motorization using micro controller; Motorizacion de valvulas de bajo coste mediante microcontrolador

    Energy Technology Data Exchange (ETDEWEB)

    Menendez, A.; Leal, M. A.; Dominguez Ademe, G.; Yaglian, E.

    2004-07-01

    This article describes a new solution for valves motorization with the objective to obtain a minimum cost and a minimum size. With it, it is proposed to facilitate the complex applications of automation in the hydraulic sector, with multiple volume and pressure controls, like the one made on Integrated Digital Control of Desalting Water Plants. The design presented here consists basically of an original mechanical connection that allows to use standard market valves and moto-gearboxes and a simplified electronic controller based on a micro controller with an elaborated software that allows to control the mother either in ON/Off (open/close) applications or in incremental applications of Regulation. (Author)

  8. Multidisciplinary optimization of a butterfly valve.

    Science.gov (United States)

    Song, Xue Guan; Wang, Lin; Baek, Seok Heum; Park, Young Chul

    2009-07-01

    A butterfly valve is a type of flow control device, typically used to regulate fluid flow. This paper proposes a new process to meet desired needs in valve design that is characterized by the complex configuration. First, the need is identified according to the valve user/company, and then the problem is defined with a characteristic function. Second, the initial model of valve is made, and then the initial analysis including fluid and/or structural analysis is carried out to predict the fluid and/or structural performance of the valve. Third, the optimization in the form of mathematical functions, which considers single or multiple objective and/or discipline, is handled. This part includes the design of computer experiment, approximation technique, topology optimization and sizing optimization. Finally, the validation experiment is conducted based on the optimum result to verify the accuracy of the optimization. An example is provided to confirm the availability of the process proposed here.

  9. Comments on compressible flow through butterfly valves

    Science.gov (United States)

    Blakenship, John G.

    In the flow analysis of process piping systems, it is desirable to treat control valves in the same way as elbow, reducers, expansions, and other pressure loss elements. In a recently reported research program, the compressible flow characteristics of butterfly valves were investigated. Fisher Controls International, Inc., manufacturer of a wide range of control valves, publishes coefficients that can be used to calculate flow characteristics for the full range of valve movement. The use is described of the manufacturer's data to calculate flow parameters as reported by the researchers who investigated compressible flow through butterfly valves. The manufacturer's data produced consistent results and can be used to predict choked flow and the pressure loss for unchoked flow.

  10. Animal Communications Through Seismic Vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Peggy (University of Tulsa)

    2001-05-02

    Substrate vibration has been important to animals as a channel of communication for millions of years, but our literature on vibration in this context of biologically relevant information is only decades old. The jaw mechanism of the earliest land vertebrates allowed them to perceive substrate vibrations as their heads lay on the ground long before airborne sounds could be heard. Although the exact mechanism of vibration production and the precise nature of the wave produced are not always understood, recent development of affordable instrumentation to detect and measure vibrations has allowed researchers to answer increasingly sophisticated questions about how animals send and receive vibration signals. We now know that vibration provides information used in predator defense, prey detection, recruitment to food, mate choice, intrasexual competition, and maternal/brood social interactions in a variety of insect orders, spiders, crabs, scorpions, chameleons, frogs, golden moles, mole rats, kangaroos rats, wallabies, elephants and bison.

  11. Risk-based approach to appraise valve closure in the clam Corbicula fluminea in response to waterborne metals

    Energy Technology Data Exchange (ETDEWEB)

    Liao, C.-M. [Department of Bioenvironmental Systems Engineering, National Taiwan University, Taipei, Taiwan 10617 (China)]. E-mail: cmliao@ntu.edu.tw; Jou, L.-J. [Department of Bioenvironmental Systems Engineering, National Taiwan University, Taipei, Taiwan 10617 (China); Department of Biomechatronic Engineering, National Ilan University, Ilan, Taiwan 260 (China); Chen, B.-C. [Department of Post-Modern Agriculture, Mingdao University, Changhua, Taiwan 52345 (China)

    2005-05-01

    We developed a risk-based approach to assess how the valve closure behavior of Asiatic clam Corbicula fluminea responds to waterborne copper (Cu) and cadmium (Cd). We reanalyzed the valve closure response data from published literature to reconstruct the response time-dependent dose-response profiles based on an empirical three-parameter Hill equation model. We integrated probabilistic exposure profiles of measured environmental Cu and Cd concentrations in the western coastal areas of Taiwan with the reconstructed dose-response relationships at different integration times of response to quantitatively estimate the valve response risk. The risk assessment results implicate exposure to waterborne Cu and Cd may pose no significant risk to clam valve activity in the short-time response periods (e.g., <30 min), yet a relative high risk for valve closure response to waterborne Cu at response times greater than 120 min is alarming. We successfully linked reconstructed dose-response profiles and EC50-time relationships associated with the fitted daily valve opening/closing rhythm characterized by a three-parameter lognormal function to predict the time-varying bivalve closure rhythm response to waterborne metals. We parameterized the proposed predictive model that should encourage a risk-management framework for discussion of future design of biological monitoring systems. - A model was developed to link valve closure in clams to concentrations of metals in water.

  12. Design of pilot-assisted load control valve with load velocity control ability and fast opening feature

    Directory of Open Access Journals (Sweden)

    Haibo Xie

    2015-11-01

    Full Text Available This article presents a design of pilot-assisted load control valve with load velocity control ability and fast opening feature based on static and dynamic modeling. Traditional load control valves do not have the load velocity control ability and its opening feature is very poor because the high spring stiffness comes along with the pressure–spring balance–based principle. Some improvement has been done by employing a two-stage pressure–pressure balance principle to make a load control valve to achieve load velocity control ability while the opening feature was not improved much. In this design, another pressure–pressure balance principle is proposed to make the load control valve achieve load velocity control ability and fast opening closing feature at the same time. Static modeling method based on force balance and Bernoulli orifice pressure-flow equation is used to design the load velocity control ability of the valve. Dynamic modeling method based on Newton’s second law and fluid continuity equation is used to optimize the parameters to give the proposed load control valve a fast opening feature. An actual load control valve was developed according to the above methods and the test results show both good load velocity control ability and fast opening feature of the design, which validates the potentiality of the proposed design in many applications.

  13. Valve-gaping behavior of raft-cultivated mussels in the Ría de Arousa, Spain

    Directory of Open Access Journals (Sweden)

    Luc A. Comeau

    2018-02-01

    Full Text Available We describe the valve-opening behavior of raft-cultivated mussels (Mytilus galloprovincialis in the Ría de Arousa (Arousa estuary, Spain. Eight rope-grown mussels [mean ± standard error (SEM, shell length 61.6 ± 2.1 mm] were connected to a non-invasive valvometry apparatus that monitored (one measurement min−1 the magnitude of valve openness systematically over a 10 day period. It was found that valves were open 97.5 ± 1.3% percent of the time. Valve closures were not synchronized among the eight monitored mussels, suggesting that feeding cessation was physiologically-regulated rather than environmentally-mediated. The opening amplitudes that were most frequently observed were in the range of 60–90%, indicating that, when open, valves are usually opened relatively close to their maximum possible extent. The majority (7/8 of mussels displayed a circadian rhythm (τ = 24.0 h in valve opening amplitude. They tended to exhibit maximum valve opening during nighttime and minimum opening during daytime. It is possible that the light:dark cycle represents an environmental zeitgeber entraining an endogenous gaping rhythm in this bivalve.

  14. Concorde noise-induced building vibrations: John F. Kennedy International Airport

    Science.gov (United States)

    Mayes, W. H.; Stephens, D. G.; Deloach, R.; Cawthorn, J. M.; Holmes, H. K.; Lewis, R. B.; Holliday, B. G.; Ward, D. W.; Miller, W. T.

    1978-01-01

    Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics.

  15. Combined effect of noise and vibration produced by high-speed trains on annoyance in buildings.

    Science.gov (United States)

    Lee, Pyoung Jik; Griffin, Michael J

    2013-04-01

    The effects of noise and vibration on annoyance in buildings during the passage of a nearby high-speed train have been investigated in a laboratory experiment with recorded train noise and 20 Hz vibration. The noises included the effects of two types of façade: windows-open and windows-closed. Subjects were exposed to six levels of noise and six magnitudes of vibration, and asked to rate annoyance using an 11-point numerical scale. The experiment consisted of four sessions: (1) evaluation of noise annoyance in the absence of vibration, (2) evaluation of total annoyance from simultaneous noise and vibration, (3) evaluation of noise annoyance in the presence of vibration, and (4) evaluation of vibration annoyance in the absence of noise. The results show that vibration did not influence ratings of noise annoyance, but that total annoyance caused by combined noise and vibration was considerably greater than the annoyance caused by noise alone. The noise annoyance and the total annoyance caused by combined noise and vibration were associated with subject self-ratings of noise sensitivity. Two classical models of total annoyance due to combined noise sources (maximum of the single source annoyance or the integration of individual annoyance ratings) provided useful predictions of the total annoyance caused by simultaneous noise and vibration.

  16. Study on decellularized porcine aortic valve/poly (3-hydroxybutyrate-co-3-hydroxyhexanoate) hybrid heart valve in sheep model.

    Science.gov (United States)

    Wu, Song; Liu, Ying-Long; Cui, Bin; Qu, Xiang-Hua; Chen, Guo-Qiang

    2007-09-01

    To overcome shortcomings of current heart valve prostheses, novel hybrid valves were fabricated from decellularized porcine aortic valves coated with poly (3-hydroxybutyrate-co-3-hydroxyhexanoate [PHBHHx]). In the mechanical test in vitro, the biomechanical performance of hybrid valve was investigated. In an in vivo study, hybrid valve conduits were implanted in pulmonary position in sheep without cardiopulmonary bypass. Uncoated grafts were used as control. The valves were explanted and examined histologically and biochemically 16 weeks after surgery. The hybrid valve conduits maintained original shapes, were covered by a confluent layer of cells, and had less calcification than uncoated control. The mechanical test in vitro revealed that PHBHHx coating improved tensile strength. The results in vivo indicated that PHBHHx coating reduced calcification and promoted the repopulation of hybrid valve with the recipient's cells resembling native valve tissue. The hybrid valve may provide superior valve replacement with current techniques.

  17. Vibration Attenuation of Plate Using Multiple Vibration Absorbers

    Directory of Open Access Journals (Sweden)

    Zaman Izzuddin

    2014-07-01

    Full Text Available Vibrations are undesired phenomenon and it can cause harm, distress and unsettling influence to the systems or structures, for example, aircraft, automobile, machinery and building. One of the approach to limit this vibration by introducing passive vibration absorber attached to the structure. In this paper, the adequacy of utilizing passive vibration absorbers are investigated. The vibration absorber system is designed to minimize the vibration of a thin plate fixed along edges. The plate’s vibration characteristics, such as, natural frequency and mode shape are determined using three techniques: theoretical equations, finite element (FE analysis and experiment. The results demonstrate that the first four natural frequencies of fixed-fixed ends plate are 48, 121, 193 and 242 Hz, and these results are corroborated well with theoretical, FE simulation and experiment. The experiment work is further carried out with attached single and multiple vibration absorbers onto plate by tuning the absorber’s frequency to match with the excitation frequency. The outcomes depict that multiple vibration absorbers are more viable in lessening the global structural vibration.

  18. Motor operated valve signatures events extraction module using an specialist system for the nuclear power plant MOV diagnostic system; Modulo de extracao de eventos em assinaturas de potencia de valvulas moto-operadas, usando um sistema especialista para o sistema de diagnostico de MOV's utilizado em reatores nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Perrenoud, Helena Guimaraes

    2001-07-01

    A predictive maintenance program for motor-operated valves is performed every year at Angra I Nuclear Power Plant in order to detect early failures of the valves and to diagnosis the valve degradation. The purpose of this maintenance program is to increase the reactor reliability and security. The main predictive maintenance activities are usually performed in the swing check-valves, gate valves and globe valves. The valves data analysis usually performed during the plant outage allows one to detect any failure and adjust the valves parameters like torque-switch and limitorque. The main purpose of this thesis is to develop a computer program to select the valve events parameter using the valve power signature during the closed-open and open-closed cycles. The results obtained by the developed algorithm are connected to a developed specialist system to perform the valves events identification. An important contribution of this thesis is that the valves signature features are obtained without changing the signal morphology. (author)

  19. Boosted PWM open loop control of hydraulic proportional valves

    Energy Technology Data Exchange (ETDEWEB)

    Amirante, R.; Catalano, L.A. [Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Via Re David 200, 70125 Bari (Italy); Innone, A. [Universita degli Studi di Foggia, via Napoli, 25 Foggia (Italy)

    2008-08-15

    This paper presents an innovative open loop control technique for direct single stage hydraulic proportional valves whose response rate is significantly higher than that obtained by standard open loop control techniques, even comparable to more costly commercial closed loop systems. Different from standard open loop techniques, which provide the coil with a constant current proportional to the target position, the control strategy proposed in this paper employs the peak and hold (P and H) technique, widely used in Diesel engine modern supply systems, to boost the duty cycle value of the pulse width modulation (PWM) signal for a short time, namely during the spool displacement, while maintaining a lower duty cycle for holding the spool in the required opening position. The developed 'boosted PWM' technique only requires a low cost microcontroller, such as a peripheral interface controller (PIC) equipped with a metal oxide semiconductor (MOS) power driver. The PWM parameters are calibrated as a function of the spool displacement so as to maximize the response rate without introducing overshoots: the collected data are stored in the PIC. Different valve opening procedures with step response have been compared to demonstrate the merits of the proposed boosted PWM technique. No overshoots have been registered. Moreover, the proposed method is characterized by a significantly higher response rate with respect to a standard open loop control, which approximately has the same cost. Similar experimental tests show that the proposed boosted PWM technique has a response rate even higher than that provided by the more costly commercial closed loop system mounted on the valve, and it produces no overshoots. (author)

  20. Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.

    Science.gov (United States)

    Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D

    2017-04-01

    To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.

  1. 3D Printed Trileaflet Valve Conduits Using Biological Hydrogels and Human Valve Interstitial Cells

    Science.gov (United States)

    Duan, Bin; Kapetanovic, Edi; Hockaday, Laura A.; Butcher, Jonathan T.

    2014-01-01

    Tissue engineering has great potential to provide a functional de novo living valve replacement capable of integration with host tissue and growth. Among various valve conduit fabrication techniques, 3D bioprinting enables deposition of cells and hydrogels into 3D constructs with anatomical geometry and heterogeneous mechanical properties. Successful translation of this approach is however constrained by the dearth of printable and biocompatible hydrogel materials. Furthermore, it is not known how human valve cells respond to these printed environments. In this study, we develop 3D printable formulations of hybrid hydrogels based on methacrylated hyaluronic acid (Me-HA) and methacrylated gelatin (Me-Gel), and utilize them to bioprint heart valve conduits containing encapsulated human aortic valvular interstitial cells (HAVIC). Increasing Me-Gel concentration resulted in lower stiffness and higher viscosity, facilitated cell spreading, and better maintained HAVIC fibroblastic phenotype. Bioprinting accuracy was dependent upon the relative concentrations of Me-Gel and Me-HA, but when optimized enabled the fabrication of a trileaflet valve shape accurate to the original design. HAVIC encapsulated within bioprinted heart valves maintained high viability, and remodeled the initial matrix by depositing collagen and glyosaminoglycans. These findings represent the first rational design of bioprinted trileaflet valve hydrogels that regulate encapsulated human VIC behavior. The use of anatomically accurate living valve scaffolds through bioprinting may accelerate our understanding of physiological valve cell interactions and our progress towards de novo living valve replacements. PMID:24334142

  2. Quadruple valve replacement with mechanical valves: an 11-year follow-up study.

    Science.gov (United States)

    Cao, Yukun; Gu, Chunhu; Sun, Guocheng; Yu, Shiqiang; Wang, Hongbing; Yi, Dinghua

    2012-06-01

    We performed the first quadruple valve replacement with mechanical valves, combined with the correction of complex congenital heart disease on November 17, 1999. We report here the 11-year follow-up study. A 47-year-old man with subacute rheumatic endocarditis, a ventricular septal defect, and an obstruction of the right ventricular outflow tract required replacement of the aortic, mitral, tricuspid, and pulmonary valves; repair of the ventricular septal defect; and relief of the obstruction of the right ventricular outflow tract. The surgery was done on November 17, 1999, after careful systemic preparation of the patient. Warfarin therapy with a target international normalized ratio (INR) range of 1.5 to 2.0 was used. Follow-up included monitoring the INR, recording the incidences of thromboembolic and bleeding events, electrocardiography, radiography, and echocardiography evaluations. The patient's INR was maintained between 1.5 and 2.0. All 4 mechanical prosthetic heart valves worked well. He is in generally good health without any thromboembolic or bleeding complications. Long-term management is challenging for patients who have experienced quadruple valve replacement with mechanical valves; however, promising results could mean that replacement of all 4 heart valves in 1 operation is feasible in patients with quadruple valve disease, and an INR of 1.5 to 2.0 could be appropriate for Chinese patients with undergoing valve replacement with mechanical valves.

  3. Good vibrations. [Hydraulic turbines

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, P.

    1994-07-01

    The latest developments in the Voith Turbine Control and Automation System (VTLS), which couples digital control technology to hydropower plant equipment, are described. Prominent among these is the vibration diagnostics module for hydraulic turbines. It provides machine-specific diagnostic logic for a vibration monitoring and analysis system. Of the two other VTLS modules described, the operation module optimizes the control of a power plant with three or more turbines by considering the individual properties of each in turn, recommending which should be run, and how, in order to partition the load for a required power output. The cavitation module is a diagnostic system which enables the limits of operation of the turbines to be extended to bands just outside those determined by cavitation calculations. (3 figures). (UK)

  4. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  5. Exercise Training in a Patient With a Left Ventricular Assist Device and Large Aortic Valve Thrombus.

    Science.gov (United States)

    Wuliya, Mijiti; Peyrot, Sandrine; Radu, Costin; Deux, Jean-François; Ben Elhaj, Habib; Lellouche, Nicolas; Damy, Thibaud; Guendouz, Soulef; Gellen, Barnabas

    2017-11-01

    An aortic valve thrombus (AVT) is a rare complication after HeartMate II implantation. In a 44-year-old man, a large AVT was discovered 6 weeks after implantation of a HeartMate II for severe dilated cardiomyopathy. The aortic valve was permanently closed. After a followup of 3 months without embolic events, the patient started a cardiac rehabilitation (CR) program involving aerobic exercise, resistance exercises, group gymnastics, and relaxation exercise, and completed the program without any complications, resulting in a significant functional benefit. CR might not be systematically contraindicated in patients with HeartMate II and an AVT, in particular, if there is no opening of the aortic valve at rest.

  6. A CASE OF SUCCESSFUL PREGNANCY WITH PROSTHETIC MITRAL VALVE COMPLICATED BY MULTIPLE ARTERIAL EMBOLISM

    Directory of Open Access Journals (Sweden)

    Prabhadevi Kodey

    2017-09-01

    Full Text Available Arterial thromboembolism is very uncommon in pregnancy. It is associated with complications like sudden death and long-term morbidity. Heart valve thrombosis without anticoagulation is devastating. All patients with mechanical prosthetic valves must continue anticoagulation without fail. If patient wants to have pregnancy, the type of anticoagulation should be changed according to period of gestation and condition. Maternal and foetal condition should be closely monitored. In patients of heart disease with mechanical prosthetic mitral valve, pregnancy is avoided due to the risk of complications during pregnancy. But, some patients insist on having a child due to their social need in spite of dreaded complications. Such patients should have anticoagulants under supervision of cardiologist.

  7. Pickin’ up good vibrations

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    In preparation for the civil engineering work on the HL-LHC, vibration measurements were carried out at the LHC’s Point 1 last month. These measurements will help evaluate how civil engineering work could impact the beam, and will provide crucial details about the site’s geological make-up before construction begins.   A seismic truck at Point 1 generated wave-like vibrations measured by EN/MME. From carrying out R&D to produce state-of-the-art magnets to developing innovative, robust materials capable of withstanding beam impact, the HL-LHC is a multi-faceted project involving many groups and teams across CERN’s departments. It was in this framework that the project management mandated CERN's Mechanical and Materials Engineering (EN/MME) group to measure the propagation of vibrations around Point 1. Their question: can civil engineering work for the HL-LHC – the bulk of which is scheduled for LS2 – begin while the LHC is running? Alth...

  8. Vibrational stability of graphene

    Directory of Open Access Journals (Sweden)

    Yangfan Hu

    2013-05-01

    Full Text Available The mechanical stability of graphene as temperature rises is analyzed based on three different self-consistent phonon (SCP models. Compared with three-dimensional (3-D materials, the critical temperature Ti at which instability occurs for graphene is much closer to its melting temperature Tm obtained from Monte Carlo simulation (Ti ≃ 2Tm, K. V. Zakharchenko, A. Fasolino, J. H. Los, and M. I. Katsnelson, J. Phys. Condens. Matter 23, 202202. This suggests that thermal vibration plays a significant role in melting of graphene while melting for 3-D materials is often dominated by topologic defects. This peculiar property of graphene derives from its high structural anisotropy, which is characterized by the vibrational anisotropic coefficient (VAC, defined upon its Lindermann ratios in different directions. For any carbon based material with a graphene-like structure, the VAC value must be smaller than 5.4 to maintain its stability. It is also found that the high VAC value of graphene is responsible for its negative thermal expansion coefficient at low temperature range. We believe that the VAC can be regarded as a new criterion concerning the vibrational stability of any low-dimensional (low-D materials.

  9. 49 CFR 192.193 - Valve installation in plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve installation in plastic pipe. 192.193... Components § 192.193 Valve installation in plastic pipe. Each valve installed in plastic pipe must be designed so as to protect the plastic material against excessive torsional or shearing loads when the valve...

  10. Towards new therapies for calcific aortic valve disease

    NARCIS (Netherlands)

    Riem Vis, P.W.

    2011-01-01

    Calcific aortic valve disease (CAVD) is characterized by progressive calcification of the aortic valve cusps. The end-stage (stenosis), can lead to heart failure and death. Approximately 2-3% of adults over 65 years of age are thought to suffer from valve stenosis, requiring aortic valve

  11. [Clinical analysis of robotic mitral valve repair].

    Science.gov (United States)

    Gao, Chang-Qing; Yang, Ming; Xiao, Cang-Song; Wang, Gang; Wang, Jia-Li; Wu, Yang; Wang, Yao

    2011-07-01

    To determine the safety and efficacy of robotic mitral valve repair using da Vinci S Surgical system. Method From January 2007 to April 2011, over 400 cases of robotic cardiac surgery have been performed, in which 60 patients with isolated mitral valve insufficiency underwent robotic mitral valve repair, including 42 male and 18 female patients with a mean age of (44 ± 13) years (ranging from 14 to 70 years). Forty-eight patients were in NYHA class I-II and 12 patients in class III. Fourteen patients were concomitant with atrial fibrillation. Surgery approach was achieved through 4 right chest ports with femoral perfusion and Chitwood aortic occlusion. Antegrade cold blood cardioplegia was administered directly via chest for myocardial protection. The transesophageal echocardiography was used intraoperatively to estimate the surgical results. All patients had successful valve repair including quadrangular resections, sliding plasties and chordal replacement. There was no conversion to median sternotomy. The mean cardiopulmonary bypass and arrested heart time were (132 ± 30) min and (88 ± 22) min. One patient had hemolysis after operation, and required mitral valve replacement. Echocardiographic follow-up revealed trace to mild regurgitation in 2 patients with a mean of (16 ± 9) months. Robotic mitral valve repair is safe and efficacious in the patients with isolated mitral valve insufficiency.

  12. Post-stressed concrete foundation may reduce machinery vibration

    Science.gov (United States)

    Fistedis, S. H.

    1967-01-01

    Post-stressing concrete mat foundation reduces excessive vibrations in machinery. The mat is stressed in compression after the machinery is mounted, thus closing any cracks in it, altering the distribution of the soil subgrade reaction on the mat, and changing the mat-subgrade natural frequency.

  13. Transient flow characteristics of a high speed rotary valve

    Science.gov (United States)

    Browning, Patrick H.

    were experimentally mapped as a function of valve speed, inter-cylinder pressure ratios and volume ratios and the results were compared to compressible flow theoretical models. Specifically, the transient behavior suggested a short-lived loss-mode initiation closely resembled by shock tube theory followed by a quasi-steady flow regime resembling choked flow behavior. An empirical model was then employed to determine the useful range of the CCV design as applied to a four-stroke CIBAI engine cycle modeled using a 1-D quasi-steady numerical method, with particular emphasis on the cyclic timing of the CCV opening. Finally, a brief discussion of a high-temperature version of the CCV design is presented.

  14. Influence of magnetic reluctances of magnetic elements on servo valve torque motors

    Science.gov (United States)

    Liu, Changhai; Jiang, Hongzhou

    2016-01-01

    The current research of electro-hydraulic servo valves mainly focuses on the vibration, pressure oscillating and source of noise. Unfortunately, literatures relating to the study of the influence of the magnetic reluctances of the magnetic elements are rarely available. This paper aims to analyze the influence of the magnetic reluctances of the magnetic elements on torque motor. Considering these magnetic reluctances ignored in previous literatures, a new mathematical model of servo valve torque motor is developed and proposed based on the fundamental laws of electromagnetism. By using this new mathematical model and the previous models, electromagnetic torque constant and magnetic spring stiffness are evaluated for a given set of torque motor parameters. A computer simulation by using AMESim software is also performed for the same set of torque motor parameters to verify the proposed model. The theoretical results of electromagnetic torque constant and magnetic spring stiffness evaluated by the proposed model render closer agreement with the simulation results than those evaluated by the previous models. In addition, an experimental measurement of the magnetic flux densities in the air-gaps is carried out by using SFL218 servo valve torque motor. Compared with the theoretical results of the magnetic flux densities in the air-gaps evaluated by the previous models, the theoretical results evaluated by the proposed model also show better agreement with the experimental data. The proposed model shows the influence of the magnetic reluctances of the magnetic elements on the servo valve torque motor, and offers modified and analytical expressions to electromagnetic torque constant and magnetic spring stiffness. These modified and analytical expressions could provide guidance more accurately for a linear control design approach and sensitivity analysis on electro-hydraulic servo valves than the previous expressions.

  15. Percutaneous management of prosthetic valve thrombosis.

    Science.gov (United States)

    Hariram, Vuppaladadhiam

    2014-01-01

    Thrombosis of a prosthetic valve is a serious complication in patients with prosthetic heart valves. Thrombolysis is the initial choice of treatment. Patients who do not respond to thrombolysis are subjected to surgery which carries a high risk. We report a case series of 5 patients with prosthetic mitral valve thrombosis who did not respond to thrombolysis and were subjected to percutaneous manipulation of the prosthetic valves successfully and improved. Five patients who were diagnosed to have prosthetic mitral valve thrombosis and failed to respond to a minimum of 36 h of thrombolysis (persistent symptoms with increased gradients, abnormal findings on fluoroscopy),were subjected to percutaneous treatment after receiving proper consent. None of them had a visible thrombus on transthoracic echocardiogram. All patients underwent transseptal puncture following which a 6F JR4 guiding catheter was passed into the left atrium. The valve leaflets were repeatedly hit gently under fluoroscopic guidance till they regained their normal mobility. Mean age was 38.8 years. Average peak and mean gradients prior to the procedure were 38 and 25 and after the procedure were 12 and 6 mm of Hg respectively. All patients had successful recovery of valve motion on fluoroscopy with normalization of gradients and complete resolution of symptoms. None of the patients had any focal neurological deficits, embolic manifestations or bleeding complications. Percutaneous manipulation of prosthetic valves in selected patients with prosthetic valve thrombosis who do not respond to thrombolytic therapy is feasible and can be used as an alternative to surgery. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  16. Transcatheter Aortic Valve Replacement: A Review Article

    Directory of Open Access Journals (Sweden)

    Juan A Siordia

    2016-06-01

    Full Text Available Transcatheter aortic valve replacement (TAVR is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive procedure and reduce common complications, such as stroke. This review article focuses on the current data on the indications, risks, benefits, and future directions of TAVR. Recently, TAVR has been considered as a standard-of-care procedure. While this technique is used frequently in high-risk surgical candidates, studies have been focusing on the application of this method for younger patients with lower surgical risk. Moreover, several studies have proposed promising results regarding the use of valve-in-valve technique or the procedure in which the valve is placed within a previously implemented bioprosthetic valve. However, ischemic strokes and paravalvular leak remain a matter of debate in these surgeries. New methods and devices have been developed to reduce the incidence of post-procedural stroke. While the third generation of TAVR valves (i.e., Edwards Sapien 3 and Medtronic Evolut R addresses the issue of paravalvular leak structurally, results on their efficacy in reducing the risk of paravalvular leak are yet to be obtained. Furthermore, TAVR enters the field of hybrid methods in the treatment of cardiac issues via both surgical and catheter-based approaches. Finally, while TAVR is primarily performed on cases with aortic stenosis, new valves and methods have been proposed regarding the application of this technique in aortic regurgitation, as well as other aortic pathologies. TAVR is a suitable therapeutic approach for the treatment of aortic stenosis in high-risk patients. Considering the promising results in the current patient population

  17. The closed circuit and the low flow systems

    Directory of Open Access Journals (Sweden)

    S Parthasarathy

    2013-01-01

    Full Text Available A breathing system is defined as an assembly of components, which delivers gases from the anesthesia machine to the patients′ airways. When the components are arranged as a circle, it is termed a circle system. The flow of exhaled gases is unidirectional in the system. The system contains a component (absorber, which absorbs exhaled carbon dioxide and it is not necessary to give high fresh gas flows as in Mapleson systems. When the adjustable pressure limiting (APL valve is closed and all the exhaled gases without carbon dioxide are returned to the patient, the system becomes a totally closed one. Such a circle system can be used with flows as low as 250 to 500 mL and clinically can be termed as low-flow systems. The components of the circle system can be arranged in different ways with adherence to basic rules: (1 Unidirectional valve must be present between the reservoir bag and the patient on both inspiratory and expiratory sides; (2 fresh gas must not enter the system between the expiratory unidirectional valve and the patient; and (3 the APL valve must not be placed between the patient and the inspiratory unidirectional valve. The functional analysis is explained in detail. During the function, the arrangement of components is significant only at higher fresh gas flows. With the introduction of low resistance valves, improved soda lime canisters and low dead space connectors, the use of less complicated pediatric circle systems is gaining popularity to anesthetize children. There are bidirectional flow systems with carbon dioxide absorption. The Waters to and fro system, a classic example of bidirectional flow systems with a canister to absorb carbon dioxide, is valveless and portable. It was widely used in the past and now is only of historical importance.

  18. An in vivo model of in situ implantation using pulmonary valved conduit in large animals under off-pump condition.

    Science.gov (United States)

    Wu, Hao; Xu, Zhi-wei; Liu, Xian-min; Gong, Da; Wan, Ju-yi; Xu, Xiu-fang; Zhou, Zi-fan; Li, Wen-bin

    2013-12-01

    The application of pulmonary valved conduit to reconstruct the continuity between right ventricles and pulmonary artery is one of the major surgeries. This study aimed to establish an in vivo model of in situ implantation using pulmonary valved conduit in large animals under off-pump condition to validate the long-term effects of artificial pulmonary valved conduit. Domesticate juvenile male sheep and tissue-engineered porcine pulmonary valved conduit were used for the experiment: 30 sheep, weighing (15 ± 3) kg (range 13 to 17 kg) were randomly divided into two groups which were all operated under general anesthesia by off-pump surgery (group 1) and left thoracotomy (group 2). Two different off-pump surgical methods were used to perform cannulation in sheep pulmonary artery to replace part of sheep pulmonary artery with pulmonary valved conduit which will work together with sheep pulmonary artery and valves. During the experiments, animal survival, complication rates, operating time and blood loss were recorded to compare the results between groups and to establish a surgical method with minimal invasion, simplicity, safety, and high success rates. In group 1, a total of 15 cases of surgeries were performed, in which two sheep died; the operative mortality was 13.3% (2/15). In group 2, a total of 15 cases of surgeries were performed, and the surgical mortality rate was 0 (0/15). The operation time and blood loss in group 2 was significantly better than that in group 1. The postoperative echocardiograms showed that, after the surgeries by these two methods, the blood flows were normal, and the valves can open and close freely. Autopsy after 6 months showed that the inner wall and the valves of pulmonary valved conduit were smooth with no thrombus formation. These two off-pump methods are feasible and safe with fewer traumas; but the second method is better and particularly suitable for the establishment of a juvenile animal model.

  19. Effect of thermal deformation on giant magnetoresistance of flexible spin valves grown on polyvinylidene fluoride membranes

    Science.gov (United States)

    Luping, Liu; Qingfeng, Zhan; Xin, Rong; Huali, Yang; Yali, Xie; Xiaohua, Tan; Run-wei, Li

    2016-07-01

    We fabricated flexible spin valves on polyvinylidene fluoride (PVDF) membranes and investigated the influence of thermal deformation of substrates on the giant magnetoresistance (GMR) behaviors. The large magnetostrictive Fe81Ga19 (FeGa) alloy and the low magnetostrictive Fe19Ni81 (FeNi) alloy were selected as the free and pinned ferromagnetic layers. In addition, the exchange bias (EB) of the pinned layer was set along the different thermal deformation axes α 31 or α 32 of PVDF. The GMR ratio of the reference spin valves grown on Si intrinsically increases with lowering temperature due to an enhancement of spontaneous magnetization. For flexible spin valves, when decreasing temperature, the anisotropic thermal deformation of PVDF produces a uniaxial anisotropy along the α 32 direction, which changes the distribution of magnetic domains. As a result, the GMR ratio at low temperature for spin valves with EB∥ α 32 becomes close to that on Si, but for spin valves with EB∥ α 31 is far away from that on Si. This thermal effect on GMR behaviors is more significant when using magnetostrictive FeGa as the free layer. Project supported by the National Natural Science Foundation of China (Grant Nos. 11374312, 51401230, 51522105, and 51471101) and the Ningbo Science and Technology Innovation Team, China (Grant No. 2015B11001).

  20. Characterization of Prototype Superfluid Helium Safety Relief Valves for the LHC Magnets

    CERN Document Server

    Dufay, L; Van Weelderen, R

    1999-01-01

    The Large Hadron Collider (LHC) at CERN will use high field superconducting magnets operating in pressurized superfluid helium (He II) at 1.9 K. Cold safety valves, with their inlet in direct contact with the He II bath, will be required to protect the cold masses in case of a magnet resistive transition. In addition to the safety function, the valves must limit their conduction heat load to the He II to below 0.3 W and limit their mass leakage when closed to below 0.01 g/s at 1.9 K with 100 mbar differential pressure. The valves must also have a high tolerance to contaminating particles in the liquid helium. The compliance with the specified performance is of crucial importance for the LHC cryogenic operation. An extensive test program is therefore being carried out on prototype industrial valves produced by four different manufacturers. The behavior of these valves has been investigated at room temperature and at 77 K. Precise heat load and mass leak measurements have been performed on a dedicated test faci...

  1. Mitigation of Shear-Induced Blood Damage of Mechanical Bileaflet Heart Valves using Embedded Vortex Generators

    Science.gov (United States)

    Hidalgo, Pablo; Arjunon, Sivakkumar; Saikrishnan, Neelakantan; Yoganathan, Ajit; Glezer, Ari

    2012-11-01

    The strong transitory shear stress generated during the time-periodic closing of the mechanical prosthetic bileaflet aortic heart valve, is considered to be one of the main factors responsible for complications, associated with thrombosis and thromboembolism. These flow transients are investigated using phase and time-averaged PIV in a low-volume (about 150 ml) test setup that simulates the pulsatile physiological conditions associated with a 23 mm St. Jude Medical valve. The PIV measurements are accompanied by continuous monitoring of the ventricular and aortic pressures and valve flow rate. Following the valve closure, the leakage flow between the valve leaflets is caused by the pressure buildup across the leaflets, leading to the formation of a regurgitation jet starting from the BMHV B-datum line. As in a typical starting jet, a counter-rotating vortex pair is formed along each leaflet edge and the vorticity sheet is associated with high shear stress that may be result in blood platelet activation. The present investigation demonstrates that the placement of arrays of mm-scale vortex generators near the edges of the leaflets diffuses the vortex sheet and suppresses the formation of these vortices, weakening the local velocity gradients and small-scale vortical structures. Supported by NIH and NSF.

  2. In vitro assessment of a new algorithm for quantitative echo measurement of heart valve regurgitant jet

    Science.gov (United States)

    Grigioni, Mauro; Tonti, Gianni; Pedrizzetti, Gianni; Daniele, Carla; D'Avenio, Giuseppe

    2003-05-01

    The measure of the regurgitant flow through heart valves provides an indication of the severity of the valve closure dysfunction with diagnostic relevance. The estimation of the volume passing through the closed valve during systole, and its ratio with the ejection volume, can significantly improve the assessment of an ongoing valvular pathology. The noninvasive quantification of flow converging to the valve is still lacking a satisfying degree of precision. The most popular technique is the Proximal Isovelocity Surface Area (PISA), which assumes that, in the flow field upstream of the valve, the surfaces corresponding to the same velocity are spherical, whence the regurgitant flow is estimated by multiplication with the hemispherical surface area. In the present study, a new method is proposed of color Doppler echocardiography image processing, for regurgitant flow measurements. In this method, called Proximal Arbitrary Surface Conservative Assessment of Leakage (PASCAL), the laws of fluid dynamics are used to reconstruct the entire flow field, in the hypothesis of axial symmetry, starting from the echographic Doppler mapping of one component of velocity. In vitro experiments have confirmed that the new method provides better flow estimates than PISA, on account of its more rigorous physical model of the regurgitant flow.

  3. Computed Flow Through An Artificial Heart Valve

    Science.gov (United States)

    Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

  4. Sensitivity study of a valve recession model

    OpenAIRE

    Vera-Cardenas, E.E.; Lewis, R; Slatter, T.

    2017-01-01

    The aim of this work was to carry out a sensitivity\\ud analysis of a valve recession model. \\ud For the sensitivity study, the effects of the param\\ud eters on the valve recession mode\\ud l were \\ud investigated, for both, light duty and heavy duty \\ud engines. It was seen that for light duty \\ud engines, the impact component parameters had the gr\\ud eatest effect on valve recession and \\ud for heavy duty engines the sliding wear component p\\ud arameters have an increasing con-\\ud tribution t...

  5. PUMP ARRANGEMENT COMPRISING A SAFETY VALVE ARRANGEMENT

    OpenAIRE

    Richter, Martin; Wackerle, Martin

    2014-01-01

    A pump arrangement comprises a microfluidic pump (20) having a pump inlet (22) and a pump outlet (24), which is configured to pump a fluid from the pump inlet to the pump outlet, wherein the pump inlet (22) and an inlet (46) of the pump arrangement are fluidically connected. The pump arrangement further comprises a safety valve arrangement having first safety valve (40), the first safety valve (40) being arranged between the pump outlet (24) and an outlet (48) of the pump arrangement and comp...

  6. Vibration of safety injection pump motors

    Energy Technology Data Exchange (ETDEWEB)

    Wattrelos, D.

    1996-12-01

    This paper covers a fault encountered in the safety injection pump motors of the French 900 MWe unit nuclear power stations. This fault was not revealed either during the low pressure safety injection and containment spray system pump qualification tests under accident conditions or during the special tests on a test bench carried out to attempt to replicate the fault and to identify ways of remedying it. This constitutes a potential common mode of failure of the safety injection system and the containment spray system pumps. The vibration phenomena illustrate the importance of carrying out tests in the plants under conditions as close as possible to those of actual accident situations.

  7. Rotary Valve FY 2016 Highlights

    Energy Technology Data Exchange (ETDEWEB)

    Fitsos, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-07

    The fiscal year started with the Rotary Valve (RV) being reassembled after having crashed in June of 2015. The crash occurred when the RV inner surface contacted the housing. The cause of the crash was never confirmed. No particles were found in the 2.5 thousandths of an inch gap and the filters the helium gas passed through were all clean. There were marks on the bearings that looked like electrostatic discharge as shown below in Figure 1. These marks hadn’t been seen before and there were similar discharge marks on some of the ball bearings. Examples of this were found in a literature search of bearing failures. This leads to a possible cause due to this arcing affecting the rotational accuracy of the bearings driving the RV into the housing.

  8. Valve Corporation: Composing Internal Markets

    Directory of Open Access Journals (Sweden)

    Todd R. Zenger

    2015-07-01

    Full Text Available Discussions of the Valve Corporation are always enlightening. The skeptic wonders how much is rhetoric and recruiting ploy and how much is real. Is there clear evidence that this organizational design actually works – that it is efficient in this setting? While revenues per employee are quite remarkable, cause and effect are unclear. Is “boss-less-ness” the cause of high sales per employee or simply the result of high sales per employee, fueled from earlier success? The same question could be asked of Google’s unusual organizational approach. Is Google’s success the result of its extensive autonomy granted to employees, or is its past success the enabling cause of such autonomy? Such questions, of course, are empirically unanswerable here. I therefore set them aside and assume this organizational specimen is efficient – well-suited to its environment – and proceed with further commentary.

  9. In vitro balloon dilatation of mitral valve stenosis: the importance of subvalvar involvement as a cause of mitral valve insufficiency

    NARCIS (Netherlands)

    Sadee, A. S.; Becker, A. E.

    1991-01-01

    To investigate the mechanism that increases the orifice area of the mitral valve during balloon dilatation 43 surgically excised intact rheumatic mitral valves were studied. The main pathological features were (a) fibrosis of mitral valve leaflets and commissures (10 valves); (b) fibrosis with

  10. 46 CFR 153.361 - Arrangements for removal of valves from venting systems having multiple relief valves.

    Science.gov (United States)

    2010-10-01

    ... having multiple relief valves. 153.361 Section 153.361 Shipping COAST GUARD, DEPARTMENT OF HOMELAND... removal of valves from venting systems having multiple relief valves. A venting system having multiple... arranged so that cargo vapor will not escape through the opening left after a valve has been removed. ...

  11. Transcatheter aortic valve implantation with balloonexpandable valve: early experience from China

    Directory of Open Access Journals (Sweden)

    Qingsheng Lu

    2015-08-01

    Full Text Available Abstract Objective: The aim of the current study was to evaluate the early experience of the application of transcatheter aortic valve implantation with the balloon-expandable system in China. The transcatheter aortic valve implantation technology has been widely used for patients with inoperable severe aortic stenosis in the developed world. The application of transcatheter aortic valve implantation is still in the early stages of testing in China, particularly for the balloon-expandable valve procedure. Methods: This was a retrospective study. All patients undergoing transcatheter aortic valve implantation with balloon-expandable system in our hospital between 2011 and 2014 were included. Edwards SAPIEN XT Transcatheter Heart Valve was used. The improvement of valve and heart function was evaluated as well as 30-day mortality and major complications according to the VARC-2 definition. Results: A total of 10 transcatheter aortic valve implantation procedures with the balloon-expandable system were performed in our hospital, of which 9 were transfemoral and 1 was transapical. The median age was 76 years, and the median STS score and Logistic EuroSCORE (% were 8.9 and 16.2. The implantation was successfully conducted in all patients, only 2 patients had mild paravalvular leak. There was no second valve implantation. Moreover, no 30-day mortality or complications was reported. Following the transcatheter aortic valve implantation procedure, the heart and valve functions had improved significantly. During the follow-up period of 3-34 months, one patient died of lung cancer 13 months after the operation. Conclusion: This early experience has provided preliminary evidence for the safety and efficacy of transcatheter aortic valve implantation procedure with the balloon-expandable system in the developing world with an increasing aging population.

  12. Osteoprotegerin inhibits aortic valve calcification and preserves valve function in hypercholesterolemic mice.

    Directory of Open Access Journals (Sweden)

    Robert M Weiss

    Full Text Available There are no rigorously confirmed effective medical therapies for calcific aortic stenosis. Hypercholesterolemic Ldlr (-/- Apob (100/100 mice develop calcific aortic stenosis and valvular cardiomyopathy in old age. Osteoprotegerin (OPG modulates calcification in bone and blood vessels, but its effect on valve calcification and valve function is not known.To determine the impact of pharmacologic treatment with OPG upon aortic valve calcification and valve function in aortic stenosis-prone hypercholesterolemic Ldlr (-/- Apob (100/100 mice.Young Ldlr (-/- Apob (100/100 mice (age 2 months were fed a Western diet and received exogenous OPG or vehicle (N = 12 each 3 times per week, until age 8 months. After echocardiographic evaluation of valve function, the aortic valve was evaluated histologically. Older Ldlr (-/- Apob (100/100 mice were fed a Western diet beginning at age 2 months. OPG or vehicle (N = 12 each was administered from 6 to 12 months of age, followed by echocardiographic evaluation of valve function, followed by histologic evaluation.In Young Ldlr (-/- Apob (100/100 mice, OPG significantly attenuated osteogenic transformation in the aortic valve, but did not affect lipid accumulation. In Older Ldlr (-/- Apob (100/100 mice, OPG attenuated accumulation of the osteoblast-specific matrix protein osteocalcin by ∼80%, and attenuated aortic valve calcification by ∼ 70%. OPG also attenuated impairment of aortic valve function.OPG attenuates pro-calcific processes in the aortic valve, and protects against impairment of aortic valve function in hypercholesterolemic aortic stenosis-prone Ldlr (-/- Apob (100/100 mice.

  13. The 3 S's of the Sapien balloon expandable valve.

    Science.gov (United States)

    Kornowski, Ran

    2016-09-01

    The Sapien 3 (S3) balloon expandable aortic valve equipped with an outer skirt to minimize paravalvular leakage (PVL) was built upon the predecessor Sapien XT (SXT) valve. There is scant comparative data of transcatheter aortic valve replacement using S3 versus SXT valve. The study shows that S3 valve is associated with reduced PVL rate compared with SXT, which is an important clinical advantage. © 2016 Wiley Periodicals, Inc.

  14. VIBRATION ISOLATION SYSTEM PROBABILITY ANALYSIS

    Directory of Open Access Journals (Sweden)

    Smirnov Vladimir Alexandrovich

    2012-10-01

    Full Text Available The article deals with the probability analysis for a vibration isolation system of high-precision equipment, which is extremely sensitive to low-frequency oscillations even of submicron amplitude. The external sources of low-frequency vibrations may include the natural city background or internal low-frequency sources inside buildings (pedestrian activity, HVAC. Taking Gauss distribution into account, the author estimates the probability of the relative displacement of the isolated mass being still lower than the vibration criteria. This problem is being solved in the three dimensional space, evolved by the system parameters, including damping and natural frequency. According to this probability distribution, the chance of exceeding the vibration criteria for a vibration isolation system is evaluated. Optimal system parameters - damping and natural frequency - are being developed, thus the possibility of exceeding vibration criteria VC-E and VC-D is assumed to be less than 0.04.

  15. Random vibrations theory and practice

    CERN Document Server

    Wirsching, Paul H; Ortiz, Keith

    1995-01-01

    Random Vibrations: Theory and Practice covers the theory and analysis of mechanical and structural systems undergoing random oscillations due to any number of phenomena— from engine noise, turbulent flow, and acoustic noise to wind, ocean waves, earthquakes, and rough pavement. For systems operating in such environments, a random vibration analysis is essential to the safety and reliability of the system. By far the most comprehensive text available on random vibrations, Random Vibrations: Theory and Practice is designed for readers who are new to the subject as well as those who are familiar with the fundamentals and wish to study a particular topic or use the text as an authoritative reference. It is divided into three major sections: fundamental background, random vibration development and applications to design, and random signal analysis. Introductory chapters cover topics in probability, statistics, and random processes that prepare the reader for the development of the theory of random vibrations a...

  16. The Vibration Ring. Phase 1; [Seedling Fund

    Science.gov (United States)

    Asnani, Vivake M.; Krantz, Timothy L.; Delap, Damon C.; Stringer, David B.

    2014-01-01

    The vibration ring was conceived as a driveline damping device to prevent structure-borne noise in machines. It has the appearance of a metal ring, and can be installed between any two driveline components like an ordinary mechanical spacer. Damping is achieved using a ring-shaped piezoelectric stack that is poled in the axial direction and connected to an electrical shunt circuit. Surrounding the stack is a metal structure, called the compression cage, which squeezes the stack along its poled axis when excited by radial driveline forces. The stack in turn generates electrical energy, which is either dissipated or harvested using the shunt circuit. Removing energy from the system creates a net damping effect. The vibration ring is much stiffer than traditional damping devices, which allows it to be used in a driveline without disrupting normal operation. In phase 1 of this NASA Seedling Fund project, a combination of design and analysis was used to examine the feasibility of this concept. Several designs were evaluated using solid modeling, finite element analysis, and by creating prototype hardware. Then an analytical model representing the coupled electromechanical response was formulated in closed form. The model was exercised parametrically to examine the stiffness and loss factor spectra of the vibration ring, as well as simulate its damping effect in the context of a simplified driveline model. The results of this work showed that this is a viable mechanism for driveline damping, and provided several lessons for continued development.

  17. Large scale steam valve test: Performance testing of large butterfly valves and full scale high flowrate steam testing

    Energy Technology Data Exchange (ETDEWEB)

    Meadows, J.B.; Robbins, G.E.; Roselius, D.G. [and others

    1995-05-01

    This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned valves operated satisfactorily under high flow conditions.

  18. A Hybrid Double Access for Transcatheter Mitral Valve-In-Valve Implantation.

    Science.gov (United States)

    Pagnotta, Paolo; Mennuni, Marco G; Ferrante, Giuseppe; Ornaghi, Diego; Bragato, Renato; Cappai, Antioco; Presbitero, Patrizia

    2015-06-01

    We present a case of hybrid mitral valve-in valve implantation. The planned transapical approach failed due to the inability to cross the degenerated stenotic mitral bioprosthesis. An alternative strategy was performed: first, an anterograde crossing of mitral stenosis, and then, a guidewire externalization through the apex by using a snare. To our knowledge, this is the first described case of double approach mitral valve-in valve implantation. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Full metal jacket: transfemoral aortic valve implantation for regurgitant valve after endovascular aortic repair†.

    Science.gov (United States)

    Tanyeli, Omer; Dereli, Yuksel; Gormus, Niyazi; Duzenli, Mehmet Akif

    2017-07-25

    Transfemoral aortic valve implantation has become an almost routine interventional procedure for severe aortic stenosis in high-risk patients. Over time an increased number of experiences has led to unusual procedures. In this report, we present a successful valve-in-valve transfemoral aortic valve implantation in a patient with aortic regurgitation, who previously had debranching and thoracic endovascular aortic repair operations. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  1. Vibration Response Characteristics of the Cross Tunnel Structure

    Directory of Open Access Journals (Sweden)

    Jinxing Lai

    2016-01-01

    Full Text Available It is well known that the tunnel structure will lose its function under the long-term repeated function of the vibration effect. A prime example is the Xi’an cross tunnel structure (CTS of Metro Line 2 and the Yongningmen tunnel, where the vibration response of the tunnel vehicle load and metro train load to the structure of shield tunnel was analyzed by applying the three-dimensional (3D dynamic finite element model. The effect of the train running was simulated by applying the time-history curves of vibration force of the track induced by wheel axles, using the fitted formulas for vehicle and train vibration load. The characteristics and the spreading rules of vibration response of metro tunnel structure were researched from the perspectives of acceleration, velocity, displacement, and stress. It was found that vehicle load only affects the metro tunnel within 14 m from the centre, and the influence decreases gradually from vault to spandrel, haunch, and springing. The high-speed driving effect of the train can be divided into the close period, the rising period, the stable period, the declining period, and the leaving period. The stress at haunch should be carefully considered. The research results presented for this case study provide theoretical support for the safety of vibration response of Metro Line 2 structure.

  2. Diesel Engine Valve Clearance Fault Diagnosis Based on Features Extraction Techniques and FastICA-SVM

    Science.gov (United States)

    Jing, Ya-Bing; Liu, Chang-Wen; Bi, Feng-Rong; Bi, Xiao-Yang; Wang, Xia; Shao, Kang

    2017-07-01

    Numerous vibration-based techniques are rarely used in diesel engines fault diagnosis in a direct way, due to the surface vibration signals of diesel engines with the complex non-stationary and nonlinear time-varying features. To investigate the fault diagnosis of diesel engines, fractal correlation dimension, wavelet energy and entropy as features reflecting the diesel engine fault fractal and energy characteristics are extracted from the decomposed signals through analyzing vibration acceleration signals derived from the cylinder head in seven different states of valve train. An intelligent fault detector FastICA-SVM is applied for diesel engine fault diagnosis and classification. The results demonstrate that FastICA-SVM achieves higher classification accuracy and makes better generalization performance in small samples recognition. Besides, the fractal correlation dimension and wavelet energy and entropy as the special features of diesel engine vibration signal are considered as input vectors of classifier FastICA-SVM and could produce the excellent classification results. The proposed methodology improves the accuracy of feature extraction and the fault diagnosis of diesel engines.

  3. Vibration analysis of the synchronous motor of a propane compressor

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, D.; Rangel Junior, J. de S. [Petroleo Brasileiro S.A. - PETROBRAS, Rio de Janeiro, RJ (Brazil)], Emails: diananogueira@petrobras.com.br, joilson_jr@petrobras.com.br; Moreira, R.G. [Petroleo Brasileiro S.A. - PETROBRAS, Cabiunas, RJ (Brazil)], E-mail: ricgmoreira@petrobras.com.br

    2010-07-01

    This paper aims at describing the Analysis of a synchronous electric motor which presented high vibration levels (shaft displacement and bearing housing vibration) during the commissioning process, as well as propose the best practices for the solution of vibration problems in similar situations. This motor belongs to the propane centrifugal compressor installed at a Gas Compression Station. The methodology used in this study conducted an investigation of the problems presented in the motor through the execution of many types of tests and the analysis of the results. The main evaluations were performed, such as the vibration analysis and the rotor dynamic analysis. The electric motor was shipped back to the manufacturer's shop, where the manufacturer made certain modifications to the motor structure so as to improve the structure stiffness, such as the improvement of the support and the increase of the thickness of the structural plates. In addition to that, the dynamic balancing of the rotating set was checked. Finally, the excitation at a critical speed close to the rated speed was found after Rotor Dynamics Analysis was performed again, because of the increase in bearing clearances. The bearing shells were replaced so as to increase the separation margin between these frequencies. In order to verify the final condition of the motor, the manufacturer repeated the standard tests - FAT (Factory Acceptance Tests) - according to internal procedure and international standards. As a result of this work, it was possible to conclude that there was a significant increase in the vibration levels due to unbalance conditions. It was also possible to conclude that there are close relationships between high vibration levels and unbalance conditions, as well as between high vibration levels and the stiffness of the system and its support. Certain points of attention related to the manufacturing process of the motor compressor are described at the end of this paper, based

  4. Process of characterization of vibration in Cofrentes NPP SRVs - scale model of main steam line; Proceso de caracterizacion de vibraciones en SRVs de C.N. Cofrentes-Modelo a escala linea de vapor principal

    Energy Technology Data Exchange (ETDEWEB)

    Galbally, D.; Hernando, J.; Garcia, G.; Barral, M.

    2014-07-01

    The Cofrentes Nuclear power plant has experienced different events anomalous related to its relief and system (SRVs) main steam safety valves. After various studies is determined that the existence of dynamics of pressure oscillations in the interior of the main steam lines is the cause of many of the events that occurred in the SRVs. To monitor these vibrations, Iberdrola performed the installation of a measuring system of vibration in SRVs and actuators during the recharge 18 (September - October 2011) with a total of 40 accelerometers distributed in 6 of the 16 existing valves. (Author)

  5. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two low-mass, linear throttling, high-efficiency, leak-proof cryogenic valves of diameters 1/2" and 4" will be built and tested. Based upon cryogenically-proven...

  6. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two cryogenic flow-control valves of diameters 1/2" and 2" will be built and tested. Based on cryogenically-proven Venturi Off-Set Technology (VOST) they have no...

  7. Modeling study of the ABS relay valve

    Science.gov (United States)

    Lei, Ming; Lin, Min; Guo, Bin; Luo, Zai; Xu, Weidong

    2011-05-01

    The ABS (anti-lock braking system) relay valve is the key component of anti-lock braking system in most commercial vehicles such as trucks, tractor-trailers, etc. In this paper, structure of ABS relay valve and its work theory were analyzed. Then a mathematical model of ABS relay valve, which was investigated by dividing into electronic part, magnetic part, pneumatic part and mechanical part, was set up. The displacement of spools and the response of pressure increasing, holding, releasing of ABS relay valve were simulated and analyzed under conditions of control pressure 500 KPa, braking pressure 600 KPa, atmospheric pressure 100 KPa and air temperature 310 K. Thisarticle provides reliable theory for improving the performance and efficiency of anti-lock braking system of vehicles.

  8. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  9. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Piezoelectric actuators constructed with the "smart material" PZT offer many potential advantages for use in NASA cryo-valve missions relative to conventional...

  10. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cryogenic flow-control valve based on Venturi-Offset Technology (VOST) will be designed and modeled. VOST provides precise linear flow control within a...

  11. Heart Valve Surgery Recovery and Follow Up

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Heart Valve Surgery Recovery and Follow Up Updated:Sep 14,2016 ... resources from Adam Pick's blog: Traveling Timeline After Heart Surgery 5 Things to Do While Your Heart Mends ( ...

  12. Posterior Urethral Valves with Severe Unilateral Vesicoureteral ...

    African Journals Online (AJOL)

    2004-08-10

    Aug 10, 2004 ... urinary catheter drainage, with no pedal oedema. There ... In patients with posterior urethral valves (PUV), severe unilateral vesicoureteral reflux (VUR) is one ... evaluation of urinary tract infection (UTI), voiding dysfunction, or ...

  13. Automatic balancing valves in distribution networks today

    Energy Technology Data Exchange (ETDEWEB)

    Golestan, F. [Flow Design, Inc., Dallas, TX (United States)

    1996-12-31

    Automatic flow-limiting (self-actuated) valves have been in the heating, ventilating, and air-conditioning (HVAC) market for some time now. Their principle of operation is based on fluid momentum and Bernoulli`s theorem. Basically, they absorb pressure to keep the flow rate constant. The general operation and their flow characteristics are described in the 1992 ASHRAE Handbook--Systems and Equipment, chapter 43 (ASHRAE 1992). The application and interaction of these valves with other system components, when installed in hydronic distribution networks, are outlined in this presentation. A simple, multilevel piping network is analyzed. The network consists of a pump, connecting piping, an automatic temperature control valve (ATC), a coil, and balancing valves.

  14. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. All rights reserved.

  15. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cylindrical, low-mass, high-efficiency, leak-proof cryogenic valve will be designed using composites and exotic metals. Based upon cryogenically-proven Venturi...

  16. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. ...

  17. A Hybrid Tissue-Engineered Heart Valve

    National Research Council Canada - National Science Library

    Alavi, S Hamed; Kheradvar, Arash

    2015-01-01

    This study describes the efforts to develop and test the first hybrid tissue-engineered heart valve whose leaflets are composed of an extra-thin superelastic Nitinol mesh tightly enclosed by uniform...

  18. Glovebox pressure relief and check valve

    Energy Technology Data Exchange (ETDEWEB)

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  19. Basis of valve operator selection for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H. S.; Lee, D. J.; See, J. K.; Park, C. K.; Choi, B. S

    2000-05-01

    SMART, an integral reactor with enhanced safety and operability, is under development for use of the nuclear energy. The valve operator of SMART system were selected through the data survey and technical review of potential valve fabrication vendors, and it will provide the establishment and optimization of the basic system design of SMART. In order to establish and optimize the basic system design of SMART, the basis of selection for the valve operator type were provided based on the basic design requirements. The basis of valve operator selection for SMART will be used as a basic technical data for the SMART basic and detail design and a fundamental material for the new reactor development in the future.

  20. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we report a case of an antenatal female in first trimester with aortic prosthetic valve thrombosis (PVT), who was successfully ...