WorldWideScience

Sample records for vessel wall cmr

  1. Right coronary wall cmr in the older asymptomatic advance cohort: positive remodeling and associations with type 2 diabetes and coronary calcium

    Directory of Open Access Journals (Sweden)

    Courtney Brian K

    2010-12-01

    Full Text Available Abstract Background Coronary wall cardiovascular magnetic resonance (CMR is a promising noninvasive approach to assess subclinical atherosclerosis, but data are limited in subjects over 60 years old, who are at increased risk. The purpose of the study was to evaluate coronary wall CMR in an asymptomatic older cohort. Results Cross-sectional images of the proximal right coronary artery (RCA were acquired using spiral black-blood coronary CMR (0.7 mm resolution in 223 older, community-based patients without a history of cardiovascular disease (age 60-72 years old, 38% female. Coronary measurements (total vessel area, lumen area, wall area, and wall thickness had small intra- and inter-observer variabilities (r = 0.93~0.99, all p Conclusions Right coronary wall CMR in asymptomatic older subjects showed increased coronary atherosclerosis in subjects with type 2 diabetes as well as coronary calcification. Coronary wall CMR may contribute to the noninvasive assessment of subclinical coronary atherosclerosis in older, at-risk patient groups.

  2. Role of arginase in vessel wall remodeling

    Directory of Open Access Journals (Sweden)

    William eDurante

    2013-05-01

    Full Text Available Arginase metabolizes the semi-essential amino acid L-arginine to L-ornithine and urea. There are two distinct isoforms of arginase, arginase I and II, which are encoded by separate genes and display differences in tissue distribution, subcellular localization, and molecular regulation. Blood vessels express both arginase I and II but their distribution appears to be cell-, vessel-, and species-specific. Both isoforms of arginase are induced by numerous pathologic stimuli and contribute to vascular cell dysfunction and vessel wall remodeling in several diseases. Clinical and experimental studies have documented increases in the expression and/or activity of arginase I or II in blood vessels following arterial injury and in pulmonary and arterial hypertension, aging, and atherosclerosis. Significantly, pharmacological inhibition or genetic ablation of arginase in animals ameliorates abnormalities in vascular cells and normalizes blood vessel architecture and function in all of these pathological states. The detrimental effect of arginase in vascular remodeling is attributable to its ability to stimulate vascular smooth muscle cell and endothelial cell proliferation, and collagen deposition by promoting the synthesis of polyamines and L-proline, respectively. In addition, arginase adversely impacts arterial remodeling by directing macrophages towards an inflammatory phenotype. Moreover, the proliferative, fibrotic, and inflammatory actions of arginase in the vasculature are further amplified by its capacity to inhibit nitric oxide synthesis by competing with nitric oxide synthase for substrate, L-arginine. Pharmacologic or molecular approaches targeting specific isoforms of arginase represent a promising strategy in treating obstructive fibroproliferative vascular disease.

  3. Intracranial vessel wall imaging at 7.0 tesla MRI

    NARCIS (Netherlands)

    van der Kolk, A.G.

    2014-01-01

    Intracranial atherosclerosis is one of the main causes of ischemic stroke. Current conventional imaging techniques assessing intracranial arterial disease in vivo only visualize the vessel wall lumen instead of the pathological vessel wall itself. Therefore, not much is known about the imaging

  4. Age determination of vessel wall hematoma in spontaneous cervical artery dissection: A multi-sequence 3T Cardiovascular Magnetic resonance study

    Directory of Open Access Journals (Sweden)

    Habs Maximilian

    2011-11-01

    Full Text Available Abstract Background Previously proposed classifications for carotid plaque and cerebral parenchymal hemorrhages are used to estimate the age of hematoma according to its signal intensities on T1w and T2w MR images. Using these classifications, we systematically investigated the value of cardiovascular magnetic resonance (CMR in determining the age of vessel wall hematoma (VWH in patients with spontaneous cervical artery dissection (sCAD. Methods 35 consecutive patients (mean age 43.6 ± 9.8 years with sCAD received a cervical multi-sequence 3T CMR with fat-saturated black-blood T1w-, T2w- and TOF images. Age of sCAD was defined as time between onset of symptoms (stroke, TIA or Horner's syndrome and the CMR scan. VWH were categorized into hyperacute, acute, early subacute, late subacute and chronic based on their signal intensities on T1w- and T2w images. Results The mean age of sCAD was 2.0, 5.8, 15.7 and 58.7 days in patients with acute, early subacute, late subacute and chronic VWH as classified by CMR (p Conclusions Signal intensities of VWH in sCAD vary over time and multi-sequence CMR can help to determine the age of an arterial dissection. Furthermore, findings of this study suggest that the time course of carotid hematomas differs from that of cerebral hematomas.

  5. Heavy wall pressure vessels for energy systems

    International Nuclear Information System (INIS)

    Canonico, D.A.

    Modifications of steels currently accepted in the Code appear to provide improved mechanical properties. These steels may permit the fabrication of larger diameter vessels with thinner section sizes and improved reliability and integrity. Adapting current specifications should expedite Code approval. Finally the challenge of improving welding procedures and adapting processes for field applications will result in higher quality weldments

  6. Vessel Wall Reaction after Vena Cava Filter Placement

    International Nuclear Information System (INIS)

    Hoekstra, Arend; Elstrodt, Jan M.; Nikkels, Peter G.J.; Tiebosch, Anton T.M.G.

    2002-01-01

    Purpose: To evaluate the interaction between the Cordis Keeper vena caval filter and vessel wall in aporcine model.Methods: Implantation of the filter was performed in five pigs. Radiologic data concerning inferior vena cava(IVC) diameter and filter patency, filter leg span, and stability were collected. At 2 or 6 months post-implantation, histopathologic analysis of the IVC wall was performed.Results: All filters remained patent with no evidence of migration. However, at 6 months follow-up, two legs of one filter penetrated the vessel wall and were adherent to the liver. These preliminary results suggest that with the observed gradual increase in the filter span, the risk of caval wall penetration increases with time, especially in a relatively small IVC(average diameter 16 mm).Conclusion: The Cordis Keeper filter was well tolerated, but seems to be prone to caval wall penetration in the long term

  7. Age determination of vessel wall hematoma in spontaneous cervical artery dissection: A multi-sequence 3T Cardiovascular Magnetic resonance study

    Science.gov (United States)

    2011-01-01

    Background Previously proposed classifications for carotid plaque and cerebral parenchymal hemorrhages are used to estimate the age of hematoma according to its signal intensities on T1w and T2w MR images. Using these classifications, we systematically investigated the value of cardiovascular magnetic resonance (CMR) in determining the age of vessel wall hematoma (VWH) in patients with spontaneous cervical artery dissection (sCAD). Methods 35 consecutive patients (mean age 43.6 ± 9.8 years) with sCAD received a cervical multi-sequence 3T CMR with fat-saturated black-blood T1w-, T2w- and TOF images. Age of sCAD was defined as time between onset of symptoms (stroke, TIA or Horner's syndrome) and the CMR scan. VWH were categorized into hyperacute, acute, early subacute, late subacute and chronic based on their signal intensities on T1w- and T2w images. Results The mean age of sCAD was 2.0, 5.8, 15.7 and 58.7 days in patients with acute, early subacute, late subacute and chronic VWH as classified by CMR (p hematomas with Cohen's kappa of 0.74 (p hematomas differs from that of cerebral hematomas. PMID:22122756

  8. [Stem and progenitor cells in biostructure of blood vessel walls].

    Science.gov (United States)

    Korta, Krzysztof; Kupczyk, Piotr; Skóra, Jan; Pupka, Artur; Zejler, Paweł; Hołysz, Marcin; Gajda, Mariusz; Nowakowska, Beata; Barć, Piotr; Dorobisz, Andrzej T; Dawiskiba, Tomasz; Szyber, Piotr; Bar, Julia

    2013-09-18

    Development of vascular and hematopoietic systems during organogenesis occurs at the same time. During vasculogenesis, a small part of cells does not undergo complete differentiation but stays on this level, "anchored" in tissue structures described as stem cell niches. The presence of blood vessels within tissue stem cell niches is typical and led to identification of niches and ensures that they are functioning. The three-layer biostructure of vessel walls for artery and vein, tunica: intima, media and adventitia, for a long time was defined as a mechanical barrier between vessel light and the local tissue environment. Recent findings from vascular biology studies indicate that vessel walls are dynamic biostructures, which are equipped with stem and progenitor cells, described as vascular wall-resident stem cells/progenitor cells (VW-SC/PC). Distinct zones for vessel wall harbor heterogeneous subpopulations of VW-SC/PC, which are described as "subendothelial or vasculogenic zones". Recent evidence from in vitro and in vivo studies show that prenatal activity of stem and progenitor cells is not only limited to organogenesis but also exists in postnatal life, where it is responsible for vessel wall homeostasis, remodeling and regeneration. It is believed that VW-SC/PC could be engaged in progression of vascular disorders and development of neointima. We would like to summarize current knowledge about mesenchymal and progenitor stem cell phenotype with special attention to distribution and biological properties of VW-SC/PC in biostructures of intima, media and adventitia niches. It is postulated that in the near future, niches for VW-SC/PC could be a good source of stem and progenitor cells, especially in the context of vessel tissue bioengineering as a new alternative to traditional revascularization therapies.

  9. Stem and progenitor cells in biostructure of blood vessel walls

    Directory of Open Access Journals (Sweden)

    Krzysztof Korta

    2013-09-01

    Full Text Available Development of vascular and hematopoietic systems during organogenesis occurs at the same time. During vasculogenesis, a small part of cells does not undergo complete differentiation but stays on this level, “anchored” in tissue structures described as stem cell niches. The presence of blood vessels within tissue stem cell niches is typical and led to identification of niches and ensures that they are functioning. The three-layer biostructure of vessel walls for artery and vein, tunica: intima, media and adventitia, for a long time was defined as a mechanical barrier between vessel light and the local tissue environment. Recent findings from vascular biology studies indicate that vessel walls are dynamic biostructures, which are equipped with stem and progenitor cells, described as vascular wall-resident stem cells/progenitor cells (VW-SC/PC. Distinct zones for vessel wall harbor heterogeneous subpopulations of VW-SC/PC, which are described as “subendothelial or vasculogenic zones”. Recent evidence from in vitro and in vivo studies show that prenatal activity of stem and progenitor cells is not only limited to organogenesis but also exists in postnatal life, where it is responsible for vessel wall homeostasis, remodeling and regeneration. It is believed that VW-SC/PC could be engaged in progression of vascular disorders and development of neointima. We would like to summarize current knowledge about mesenchymal and progenitor stem cell phenotype with special attention to distribution and biological properties of VW-SC/PC in biostructures of intima, media and adventitia niches. It is postulated that in the near future, niches for VW-SC/PC could be a good source of stem and progenitor cells, especially in the context of vessel tissue bioengineering as a new alternative to traditional revascularization therapies.

  10. Properties of CMR composites

    Indian Academy of Sciences (India)

    Unknown

    Department of Metallurgical Engineering and Materials Science, Indian. Institute ... Colossal magnetoresistance (CMR) composites form an interesting field ..... field and composition sensitive competition between the positive and negative MR.

  11. Structural Alterations of the Glomerular Wall And Vessels in Early ...

    African Journals Online (AJOL)

    Structural Alterations of the Glomerular Wall And Vessels in Early Stages of Diabetes Mellitus: Light and Transmission Electron Microscopic Study. ... The second group of 20 (the experimental group) was injected intraperitoneally by a single dose of streptozotocin to induce hyperglycemia. Rats were sacrificed after ten days, ...

  12. Vessel wall reaction after vena cava filter placement

    NARCIS (Netherlands)

    Hoekstra, A; Elstrodt, JM; Nikkels, PGJ; Tiebosch, ATMG

    2002-01-01

    Purpose: To evaluate the interaction between the Cordis Keeper vena caval filter and vessel wall in a porcine model. Methods: Implantation of the filter was performed in five pigs. Radiologic data concerning inferior vena cava (IVC) diameter and filter patency, filter leg span, and stability were

  13. Platelet-vessel wall interaction in health and disease

    NARCIS (Netherlands)

    Löwenberg, E. C.; Meijers, J. C. M.; Levi, M. [=Marcel M.

    2010-01-01

    Upon vessel wall injury platelets rapidly adhere to the exposed subendothelial matrix which is mediated by several cellular receptors present on platelets or endothelial cells and various adhesive proteins such as von Willebrand factor, collagen and fibrinogen. Subsequent platelet activation results

  14. CMR in Heart Failure.

    OpenAIRE

    Sado, D. M.; Hasleton, J. M.; Herrey, A. S.; Moon, J. C.

    2011-01-01

    Heart Failure (HF) is a common syndrome with multiple causes. Cardiovascular magnetic resonance (CMR) is a medical imaging technique with significant advantages, allowing the understanding of aetiology and pathophysiology of HF in the individual patient, permitting specific therapy to be administered and predicting prognosis. This paper discusses the diverse role of CMR in HF.

  15. Intracranial arterial aneurysm vasculopathies: targeting the outer vessel wall

    International Nuclear Information System (INIS)

    Krings, Timo; Piske, Ronie L.; Lasjaunias, Pierre L.

    2005-01-01

    The pathogenesis of intracranial arterial aneurysms (AA) remains unclear, despite their clinical importance. An improved understanding of this disease is important in choosing therapeutic options. In addition to the ''classical'' berry-type aneurysm, there are various other types of intracranial AA such as infectious, dissecting or giant, partially-thrombosed aneurysms. From the clinician's perspective, the hypothesis that some of these intracranial AA might be due to abluminal factors has been proposed for several years. Indeed, this hypothesis and the empirical use of anti-inflammatory drugs in giant intracranial aneurysms have been confirmed by recent studies reporting that an enzyme involved in the inflammatory cascade (5-lipoxygenase or 5-LO) promotes the pathogenesis of specific aneurysms in humans. 5-LO generates different forms of leukotrienes which are potent mediators of inflammation. Adventitial inflammation leads to a weakening of the media from the abluminal part of the vessel wall due to the release of proinflammatory factors that invade the media, thereby degrading the extracellular matrix, the elastic lamina of the vascular wall, and, finally, the integrity of the vessel lumen. This in turn results in a dilation of the vessel and aneurysm formation. Moreover, neoangiogenesis of vasa vasorum is found in close proximity to 5-LO activated macrophages. In addition to this biological cascade, we argue that repeated subadventitial haemorrhages from the new vasa vasorum play an important role in aneurysm pathogenesis, due to a progressive increase in size mediated by the apposition of new layers of intramural haematoma within the vessel wall. Intracranial giant AA can therefore be regarded as a proliferative disease of the vessel wall induced by extravascular activity. (orig.)

  16. Computational scheme for transient temperature distribution in PWR vessel wall

    International Nuclear Information System (INIS)

    Dedovic, S.; Ristic, P.

    1980-01-01

    Computer code TEMPNES is a part of joint effort made in Gosa Industries in achieving the technique for structural analysis of heavy pressure vessels. Transient heat conduction problems analysis is based on finite element discretization of structures non-linear transient matrix formulation and time integration scheme as developed by Wilson (step-by-step procedure). Convection boundary conditions and the effect of heat generation due to radioactive radiation are both considered. The computation of transient temperature distributions in reactor vessel wall when the water temperature suddenly drops as a consequence of reactor cooling pump failure is presented. The vessel is treated as as axisymmetric body of revolution. The program has two finite time element options a) fixed predetermined increment and; b) an automatically optimized time increment for each step dependent on the rate of change of the nodal temperatures. (author)

  17. Molecular magnetic resonance imaging of atherosclerotic vessel wall disease

    Energy Technology Data Exchange (ETDEWEB)

    Noerenberg, Dominik [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); University of Munich - Grosshadern, Department of Clinical Radiology, Munich (Germany); Ebersberger, Hans U. [Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Diederichs, Gerd; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Botnar, Rene M. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Makowski, Marcus R. [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2016-03-15

    Molecular imaging aims to improve the identification and characterization of pathological processes in vivo by visualizing the underlying biological mechanisms. Molecular imaging techniques are increasingly used to assess vascular inflammation, remodeling, cell migration, angioneogenesis and apoptosis. In cardiovascular diseases, molecular magnetic resonance imaging (MRI) offers new insights into the in vivo biology of pathological vessel wall processes of the coronary and carotid arteries and the aorta. This includes detection of early vascular changes preceding plaque development, visualization of unstable plaques and assessment of response to therapy. The current review focuses on recent developments in the field of molecular MRI to characterise different stages of atherosclerotic vessel wall disease. A variety of molecular MR-probes have been developed to improve the non-invasive detection and characterization of atherosclerotic plaques. Specifically targeted molecular probes allow for the visualization of key biological steps in the cascade leading to the development of arterial vessel wall lesions. Early detection of processes which lead to the development of atherosclerosis and the identification of vulnerable atherosclerotic plaques may enable the early assessment of response to therapy, improve therapy planning, foster the prevention of cardiovascular events and may open the door for the development of patient-specific treatment strategies. (orig.)

  18. Molecular magnetic resonance imaging of atherosclerotic vessel wall disease

    International Nuclear Information System (INIS)

    Noerenberg, Dominik; Ebersberger, Hans U.; Diederichs, Gerd; Hamm, Bernd; Botnar, Rene M.; Makowski, Marcus R.

    2016-01-01

    Molecular imaging aims to improve the identification and characterization of pathological processes in vivo by visualizing the underlying biological mechanisms. Molecular imaging techniques are increasingly used to assess vascular inflammation, remodeling, cell migration, angioneogenesis and apoptosis. In cardiovascular diseases, molecular magnetic resonance imaging (MRI) offers new insights into the in vivo biology of pathological vessel wall processes of the coronary and carotid arteries and the aorta. This includes detection of early vascular changes preceding plaque development, visualization of unstable plaques and assessment of response to therapy. The current review focuses on recent developments in the field of molecular MRI to characterise different stages of atherosclerotic vessel wall disease. A variety of molecular MR-probes have been developed to improve the non-invasive detection and characterization of atherosclerotic plaques. Specifically targeted molecular probes allow for the visualization of key biological steps in the cascade leading to the development of arterial vessel wall lesions. Early detection of processes which lead to the development of atherosclerosis and the identification of vulnerable atherosclerotic plaques may enable the early assessment of response to therapy, improve therapy planning, foster the prevention of cardiovascular events and may open the door for the development of patient-specific treatment strategies. (orig.)

  19. Design optimization of a thin walled pressure vessel

    International Nuclear Information System (INIS)

    Sadiq, S.

    2001-01-01

    Design evaluation of a pressure vessel is not only to build confidence on its integrity but also to reduce structural weight and enhance the performance of the structure. Pressure vessel, e.g., a rocket motor not only has to withstand the high operating temperatures but it must also be able to survive the internal pressures and external aerodynamic forces and bending stresses during its operation in flight. A research program was devised to study the stresses, which are generated in a thin walled pressure vessel during actual operation and its simulation with cold testing technique, i.e., by means of hydrostatic testing employing electrical resistance strain gauges on the external surface of the cylinder. The objective of the research was to uphold the performance of the vessel by reducing its thickness from 6.09 to 5.5 mm (which of course reduces the safety factor margin from 1.8 to 1.5); thereby curtailing the overall structural weight and maintaining the efficiency of the vessel itself during its live operation. The techniques employed were hydrostatic testing, data acquisition system for obtaining data on strains from the electrical resistance strain gauges and later employing V on Mises yield criterion empirical relation to computer the stresses in hoop and longitudinal directions. (author)

  20. Welding distortion control in double walled KSTAR vacuum vessel fabrication

    International Nuclear Information System (INIS)

    Oh, D. W.; Lee, G. T.; Kim, H. K.; Yang, H. L.; Bak, J. S.

    2004-01-01

    The KSTAR(Korea Superconducting Tokamak Advanced Research) vacuum vessel is designed to be a double walled structure made of 12mm thick 316LN stainless steel with a D shaped cross-section about 4 m height. Vacuum vessel was pre-fabricated in two parts, 180 degree and 157.5 degree sectors in toroidal direction to meet the transportation purpose. These two parts have to be welded on site with ±2mm allowable fabrication tolerances. 1/3 scaled mock-up model was used to estimate the welding distortion and to ensure the weld quality of vacuum vessel. Gas Tungsten Arc Welding(GTAW), which has been approved by procedure qualification test, was used during mock-up test and vacuum vessel site fabrication. Welding distortion could be managed by allowing for distortion in opposite direction, by applying high restraint using lots of strong backs, by controlling the welding heat input with symmetrical welding sequence. The integrity of the site welding joint was assured by radiographic test, ultrasonic test and leak test with helium detecting method

  1. Automated image segmentation and registration of vessel wall MRI for quantitative assessment of carotid artery vessel wall dimensions and plaque composition

    NARCIS (Netherlands)

    Klooster, Ronald van 't

    2014-01-01

    The main goal of this thesis was to develop methods for automated segmentation, registration and classification of the carotid artery vessel wall and plaque components using multi-sequence MR vessel wall images to assess atherosclerosis. First, a general introduction into atherosclerosis and

  2. Erosion and redeposition at the vessel walls in fusion devices

    International Nuclear Information System (INIS)

    Naujoks, D.; Behrisch, R.

    1995-01-01

    The plasma induced erosion and redeposition at the vessel walls in today's fusion devices have been investigated both with the computer simulation code ERO, and in experiments. Well prepared carbon probes with implanted and evaporated markers in the surface layers have been exposed in the scrape-off layer (SOL) of several tokamaks such as JET, TEXTOR and ASDEX-Upgrade. The main plasma parameters (electron density and temperature, impurity concentration in the SOL) are simultaneously determined. After exposure to single plasma discharges, erosion and redeposition of the marker material were measured by surface layer analysis with MeV ion beam techniques. The experimental results were compared with the results from the ERO code. The measured erosion/redeposition could be described with ERO, which takes into account the impurity concentration in the SOL, the dynamical change of the surface composition (causing a modification of the sputtering yield during the exposure) and ExB drift effects. ((orig.))

  3. Subclavian vein aneurysm secondary to a benign vessel wall hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Patrick [Nationwide Children' s Hospital, Section of Pediatric Interventional Radiology, Columbus, OH (United States); Spaeth, Maya [Nationwide Children' s Hospital, Section of Plastic and Reconstructive Surgery, Columbus, OH (United States); Prasad, Vinay [Nationwide Children' s Hospital, Section of Pediatric Pathology, Columbus, OH (United States); McConnell, Patrick [Nationwide Children' s Hospital, Section of Cardiothoracic Surgery, Columbus, OH (United States)

    2013-11-15

    Venous aneurysms are rare clinical entities, particularly in children, and their presentation and natural history often depend on the anatomical location and underlying etiology. We present a single case of a 12-year-old girl who presented with a palpable right supraclavicular mass. Imaging evaluation with CT, conventional venography, MRI and sonography revealed a large fusiform subclavian vein aneurysm with an unusual, mass-like fibrofatty component incorporated into the vessel wall. The girl ultimately required complete resection of the right subclavian vein with placement of a synthetic interposition graft. This case provides a radiology/pathology correlation of an entity that has not previously been described as well as an example of the utility of multiple imaging modalities to aid diagnosis and preoperative planning. (orig.)

  4. System for cooling the upper wall of a nuclear reactor vessel

    International Nuclear Information System (INIS)

    Pailla, Henri; Schaller, Karl; Vidard, Michel.

    1974-01-01

    A system for cooling the upper wall of the main vessel of a fast neutron reactor is described. This vessel is suspended from an upper shield by the upper wall. It includes coils carrying a coolant which are immersed in an intermediate liquid bathing the wall and contained in a tank integral with the vessel. At least one of the two cooling and intermediate liquids is a liquid metal. The main vessel is contained in a safety vessel, the space between the main and safety vessels is occluded in its upper part by an insulating shield placed under the tank. There is a liquid metal seal between the upper wall and the upper shield under the tank. This system has been specially designed for sodium cooled fast neutron reactors [fr

  5. Plasma discharge in ferritic first wall vacuum vessel of the Hitachi Tokamak HT-2

    International Nuclear Information System (INIS)

    Abe, Mitsushi; Nakayama, Takeshi; Asano, Katsuhiko; Otsuka, Michio

    1997-01-01

    A tokamak discharge with ferritic material first wall was tried successfully. The Hitachi Tokamak HT-2 had a stainless steel SUS304 vacuum vessel and modified to have a ferritic plate first wall for experiments to investigate the possibility of ferritic material usage in magnetic fusion devices. The achieved vacuum pressure and times used for discharge cleaning was roughly identical with the stainless steel first wall or the original HT-2. We concluded that ferritic material vacuum vessel is possible for tokamaks. (author)

  6. Behaviour of Viscoelastic - Viscoplastic Spheres and Cylinders - Partly Plastic Vessel Walls

    DEFF Research Database (Denmark)

    Ottosen, N. Saabye

    1985-01-01

    The material model consists of a viscoelastic Burgers element and an additional viscoplastic Bingham element when the effective stress exceeds the yield stress. For partly plastic vessel walls, expressions are derived for the stress and strain state in pressurised or relaxation loaded thick......-walled cylinders in plane strain and spheres. For the spherical problem, the material compressibility is accounted for. The influence of the different material parameters on the behaviour of the vessels is evaluated. It is shown that the magnitude of the Maxwell viscosity is of major importance for the long......-term behaviour of thick-walled partly plastic vessels....

  7. Behaviour of Viscoelastic - Viscoplastic Spheres and Cylinders - Fully Plastic Vessel Walls

    DEFF Research Database (Denmark)

    Ottosen, N. Saabye

    1985-01-01

    The material model consists of a viscoelastic Burgers element and an additional viscoplastic Bingham element when the effective stress exceeds the yield stress. For fully plastic vessel walls, exact closed-form expressions arc derived for the stress and strain state in pressurised or relaxation...... loaded thick-walled cylinders in plane strain and spheres. For the spherical problem, the material compressibility is accounted for. The influence of the different material parameters on the behaviour of the vessels is evaluated. It is shown that the magnitude of the Maxwell viscosity is of major...... importance for the long-term behaviour of thick-walled fully plastic vessels....

  8. Quantification of common carotid artery and descending aorta vessel wall thickness from MR vessel wall imaging using a fully automated processing pipeline.

    Science.gov (United States)

    Gao, Shan; van 't Klooster, Ronald; Brandts, Anne; Roes, Stijntje D; Alizadeh Dehnavi, Reza; de Roos, Albert; Westenberg, Jos J M; van der Geest, Rob J

    2017-01-01

    To develop and evaluate a method that can fully automatically identify the vessel wall boundaries and quantify the wall thickness for both common carotid artery (CCA) and descending aorta (DAO) from axial magnetic resonance (MR) images. 3T MRI data acquired with T 1 -weighted gradient-echo black-blood imaging sequence from carotid (39 subjects) and aorta (39 subjects) were used to develop and test the algorithm. The vessel wall segmentation was achieved by respectively fitting a 3D cylindrical B-spline surface to the boundaries of lumen and outer wall. The tube-fitting was based on the edge detection performed on the signal intensity (SI) profile along the surface normal. To achieve a fully automated process, Hough Transform (HT) was developed to estimate the lumen centerline and radii for the target vessel. Using the outputs of HT, a tube model for lumen segmentation was initialized and deformed to fit the image data. Finally, lumen segmentation was dilated to initiate the adaptation procedure of outer wall tube. The algorithm was validated by determining: 1) its performance against manual tracing; 2) its interscan reproducibility in quantifying vessel wall thickness (VWT); 3) its capability of detecting VWT difference in hypertensive patients compared with healthy controls. Statistical analysis including Bland-Altman analysis, t-test, and sample size calculation were performed for the purpose of algorithm evaluation. The mean distance between the manual and automatically detected lumen/outer wall contours was 0.00 ± 0.23/0.09 ± 0.21 mm for CCA and 0.12 ± 0.24/0.14 ± 0.35 mm for DAO. No significant difference was observed between the interscan VWT assessment using automated segmentation for both CCA (P = 0.19) and DAO (P = 0.94). Both manual and automated segmentation detected significantly higher carotid (P = 0.016 and P = 0.005) and aortic (P < 0.001 and P = 0.021) wall thickness in the hypertensive patients. A reliable and reproducible pipeline for fully

  9. Evaluation of carotid vessel wall enhancement with image subtraction after gadobenate dimeglumine-enhanced MR angiography

    International Nuclear Information System (INIS)

    Sardanelli, Francesco; Di Leo, Giovanni; Aliprandi, Alberto; Flor, Nicola; Papini, Giacomo D.E.; Roccatagliata, Luca; Cotticelli, Biagio; Nano, Giovanni; Cornalba, Gianpaolo

    2009-01-01

    Objectives: This study was aimed at testing the value of image subtraction for evaluating carotid vessel wall enhancement in contrast-enhanced MR angiography (MRA). Materials and methods: IRB approval was obtained. The scans of 81 consecutive patients who underwent carotid MRA with 0.1 mmol/kg of gadobenate dimeglumine were reviewed. Axial carotid 3D T1-weighted fast low-angle shot sequence before and 3 min after contrast injection were acquired and subtracted (enhanced minus unenhanced). Vessel wall enhancement was assigned a four-point score using native or subtracted images from 0 (no enhancement) to 3 (strong enhancement). Stenosis degree was graded according to NASCET. Results: With native images, vessel wall enhancement was detected in 20/81 patients (25%) and in 20/161 carotids (12%), and scored 2.0 ± 0.6 (mean ± standard deviation); with subtracted images, in 21/81 (26%) and 22/161 (14%), and scored 2.5 ± 0.6, respectively (P < 0.001, Sign test). The overall stenosis degree distribution was: mild, 41/161 (25%); moderate, 77/161 (48%); severe, 43/161 (27%). Carotids with moderate stenosis showed vessel wall enhancement with a frequency (17/77, 22%) significantly higher than that observed in carotids with mild stenosis (1/41, 2%) (P = 0.005, Fisher exact test) and higher, even though with borderline significance (P = 0.078, Fisher exact test), than that observed in carotids with severe stenosis (4/43, 9%). Conclusion: Roughly a quarter of patients undergoing carotid MRA showed vessel wall enhancement. Image subtraction improved vessel wall enhancement conspicuity. Vessel wall enhancement seems to be an event relatively independent from the degree of stenosis. Further studies are warranted to define the relation between vessel wall enhancement and histopathology, inflammatory status, and instability.

  10. Strength-toughness requirements for thick walled high pressure vessels

    International Nuclear Information System (INIS)

    Kapp, J.A.

    1990-01-01

    The strength and toughness requirements of materials for use in high pressure vessels has been the subject of some discussion in the meetings of the Materials Task Group of the Special Working Group High Pressure Vessels. A fracture mechanics analysis has been performed to theoretically establish the required toughness for a high pressure vessel. This paper reports that the analysis performed is based on the validity requirement for plane strain fracture of fracture toughness test specimens. This is that at the fracture event, the crack length, uncracked ligament, and vessel length must each be greater than fifty times the crack tip plastic zone size for brittle fracture to occur. For high pressure piping applications, the limiting physical dimension is the uncracked ligament, as it can be assumed that the other dimensions are always greater than fifty times the crack tip plastic zone. To perform the fracture mechanics analysis several parameters must be known: these include vessel dimensions, material strength, degree of autofrettage, and design pressure. Results of the analysis show, remarkably, that the effects of radius ratio, pressure and degree of autofrettage can be ignored when establishing strength and toughness requirements for code purposes. The only parameters that enter into the calculation are yield strength, toughness and vessel thickness. The final results can easily be represented as a graph of yield strength against toughness on which several curves, one for each vessel thickness, are plotted

  11. Simulation of Diffusive Lithium Evaporation Onto the NSTX Vessel Walls

    International Nuclear Information System (INIS)

    Stotler, D.P.; Skinner, C.H.; Blanchard, W.R.; Krstic, P.S.; Kugel, H.W.; Schneider, H.; Zakharov, L.E.

    2010-01-01

    A model for simulating the diffusive evaporation of lithium into a helium filled NSTX vacuum vessel is described and validated against an initial set of deposition experiments. The DEGAS 2 based model consists of a three-dimensional representation of the vacuum vessel, the elastic scattering process, and a kinetic description of the evaporated atoms. Additional assumptions are required to account for deuterium out-gassing during the validation experiments. The model agrees with the data over a range of pressures to within the estimated uncertainties. Suggestions are made for more discriminating experiments that will lead to an improved model.

  12. Proteomic profiling of tissue-engineered blood vessel walls constructed by adipose-derived stem cells.

    Science.gov (United States)

    Wang, Chen; Guo, Fangfang; Zhou, Heng; Zhang, Yun; Xiao, Zhigang; Cui, Lei

    2013-02-01

    Adipose-derived stem cells (ASCs) can differentiate into smooth muscle cells and have been engineered into elastic small diameter blood vessel walls in vitro. However, the mechanisms involved in the development of three-dimensional (3D) vascular tissue remain poorly understood. The present study analyzed protein expression profiles of engineered blood vessel walls constructed by human ASCs using methods of two-dimensional gel electrophoresis (2DE) and mass spectrometry (MS). These results were compared to normal arterial walls. A total of 1701±15 and 1265±26 protein spots from normal and engineered blood vessel wall extractions were detected by 2DE, respectively. A total of 20 spots with at least 2.0-fold changes in expression were identified, and 38 differently expressed proteins were identified by 2D electrophoresis and ion trap MS. These proteins were classified into seven functional categories: cellular organization, energy, signaling pathway, enzyme, anchored protein, cell apoptosis/defense, and others. These results demonstrated that 2DE, followed by ion trap MS, could be successfully utilized to characterize the proteome of vascular tissue, including tissue-engineered vessels. The method could also be employed to achieve a better understanding of differentiated smooth muscle protein expression in vitro. These results provide a basis for comparative studies of protein expression in vascular smooth muscles of different origin and could provide a better understanding of the mechanisms of action needed for constructing blood vessels that exhibit properties consistent with normal blood vessels.

  13. Pressure vessel rupture within a chamber: the pressure history on the chamber wall

    International Nuclear Information System (INIS)

    Baum, M.R.

    1989-04-01

    Generally there is a large number of pressure vessels containing high pressure gas on power stations and chemical plant. In many instances, particularly on power plant, these vessels are within the main building. If a pressure vessel were to fail, the surrounding structures would be exposed to blast loads and the forces resulting from jets of fluid issuing from the breached vessel. In the case where the vessel is in a relatively closed chamber there would also be a general overpressurisation of the chamber. At the design stage it is therefore essential to demonstrate that the plant could be safely shut down in the event of a pressure vessel failure, that is, it must be shown that the chamber will not collapse thus putting the building at risk or hazarding equipment essential for a safe shut down. Such an assessment requires the loads applied to the chamber walls, roof, etc. to be known. (author)

  14. Segmentation of arterial vessel wall motion to sub-pixel resolution using M-mode ultrasound.

    Science.gov (United States)

    Fancourt, Craig; Azer, Karim; Ramcharan, Sharmilee L; Bunzel, Michelle; Cambell, Barry R; Sachs, Jeffrey R; Walker, Matthew

    2008-01-01

    We describe a method for segmenting arterial vessel wall motion to sub-pixel resolution, using the returns from M-mode ultrasound. The technique involves measuring the spatial offset between all pairs of scans from their cross-correlation, converting the spatial offsets to relative wall motion through a global optimization, and finally translating from relative to absolute wall motion by interpolation over the M-mode image. The resulting detailed wall distension waveform has the potential to enhance existing vascular biomarkers, such as strain and compliance, as well as enable new ones.

  15. Two Complementary Mechanisms Underpin Cell Wall Patterning during Xylem Vessel Development.

    Science.gov (United States)

    Schneider, Rene; Tang, Lu; Lampugnani, Edwin R; Barkwill, Sarah; Lathe, Rahul; Zhang, Yi; McFarlane, Heather E; Pesquet, Edouard; Niittyla, Totte; Mansfield, Shawn D; Zhou, Yihua; Persson, Staffan

    2017-10-01

    The evolution of the plant vasculature was essential for the emergence of terrestrial life. Xylem vessels are solute-transporting elements in the vasculature that possess secondary wall thickenings deposited in intricate patterns. Evenly dispersed microtubule (MT) bands support the formation of these wall thickenings, but how the MTs direct cell wall synthesis during this process remains largely unknown. Cellulose is the major secondary wall constituent and is synthesized by plasma membrane-localized cellulose synthases (CesAs) whose catalytic activity propels them through the membrane. We show that the protein CELLULOSE SYNTHASE INTERACTING1 (CSI1)/POM2 is necessary to align the secondary wall CesAs and MTs during the initial phase of xylem vessel development in Arabidopsis thaliana and rice ( Oryza sativa ). Surprisingly, these MT-driven patterns successively become imprinted and sufficient to sustain the continued progression of wall thickening in the absence of MTs and CSI1/POM2 function. Hence, two complementary principles underpin wall patterning during xylem vessel development. © 2017 American Society of Plant Biologists. All rights reserved.

  16. High-resolution intracranial vessel wall MRI in an elderly asymptomatic population: comparison of 3T and 7T

    Energy Technology Data Exchange (ETDEWEB)

    Harteveld, Anita A.; Kolk, Anja G. van der; Dieleman, Nikki; Siero, Jeroen C.W.; Luijten, Peter R.; Zwanenburg, Jaco J.M.; Hendrikse, Jeroen [University Medical Center Utrecht, Department of Radiology, Postbox 85500, Utrecht (Netherlands); Worp, H.B. van der; Frijns, Catharina J.M. [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, Utrecht (Netherlands); Kuijf, Hugo J. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2017-04-15

    Several intracranial vessel wall sequences have been described in recent literature, with either 3-T or 7-T magnetic resonance imaging (MRI). In the current study, we compared 3-T and 7-T MRI in visualising both the intracranial arterial vessel wall and vessel wall lesions. Twenty-one elderly asymptomatic volunteers were scanned by 3-T and 7-T MRI with an intracranial vessel wall sequence, both before and after contrast administration. Two raters scored image quality, and presence and characteristics of vessel wall lesions. Vessel wall visibility was equal or significantly better at 7 T for the studied arterial segments, even though there were more artefacts hampering assessment. The better visualisation of the vessel wall at 7 T was most prominent in the proximal anterior cerebral circulation and the posterior cerebral artery. In the studied elderly asymptomatic population, 48 vessel-wall lesions were identified at 3 T, of which 7 showed enhancement. At 7 T, 79 lesions were identified, of which 29 showed enhancement. Seventy-one percent of all 3-T lesions and 59 % of all 7-T lesions were also seen at the other field strength. Despite the large variability in detected lesions at both field strengths, we believe 7-T MRI has the highest potential to identify the total burden of intracranial vessel wall lesions. (orig.)

  17. Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis

    International Nuclear Information System (INIS)

    Spuentrup, Elmar; Botnar, Rene M.

    2006-01-01

    Coronary magnetic resonance (MR) imaging has dramatically emerged over the last decade. Technical improvements have enabled reliable visualization of the proximal and midportion of the coronary artery tree for exclusion of significant coronary artery disease. However, current technical developments focus also on direct visualization of the diseased coronary vessel wall and imaging of coronary plaque because plaques without stenoses are typically more vulnerable with higher risk of plaque rupture. Plaque rupture with subsequent thrombosis and vessel occlusion is the main cause of myocardial infarction. Very recently, the first success of molecular imaging in the coronary arteries has been demonstrated using a fibrin-specific contrast agent for selective visualization of coronary thrombosis. This demonstrates in general the high potential of molecular MR imaging in the field of coronary artery disease. In this review, we will address recent technical advances in coronary MR imaging, including visualization of the lumen and the vessel wall and molecular imaging of coronary arteriothrombosis. First results of these new approaches will be discussed. (orig.)

  18. Assessment of turbulent flow effects on the vessel wall using four-dimensional flow MRI.

    Science.gov (United States)

    Ziegler, Magnus; Lantz, Jonas; Ebbers, Tino; Dyverfeldt, Petter

    2017-06-01

    To explore the use of MR-estimated turbulence quantities for the assessment of turbulent flow effects on the vessel wall. Numerical velocity data for two patient-derived models was obtained using computational fluid dynamics (CFD) for two physiological flow rates. The four-dimensional (4D) Flow MRI measurements were simulated at three different spatial resolutions and used to investigate the estimation of turbulent wall shear stress (tWSS) using the intravoxel standard deviation (IVSD) of velocity and turbulent kinetic energy (TKE) estimated near the vessel wall. Accurate estimation of tWSS using the IVSD is limited by the spatial resolution achievable with 4D Flow MRI. TKE, estimated near the wall, has a strong linear relationship to the tWSS (mean R 2  = 0.84). Near-wall TKE estimates from MR simulations have good agreement to CFD-derived ground truth (mean R 2  = 0.90). Maps of near-wall TKE have strong visual correspondence to tWSS. Near-wall estimation of TKE permits assessment of relative maps of tWSS, but direct estimation of tWSS is challenging due to limitations in spatial resolution. Assessment of tWSS and near-wall TKE may open new avenues for analysis of different pathologies. Magn Reson Med 77:2310-2319, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  19. Intracranial Vascular Disease Evaluation With Combined Vessel Wall Imaging And Patient Specific Hemodynamics

    Science.gov (United States)

    Samson, Kurt; Mossa-Basha, Mahmud; Yuan, Chun; Canton, Maria De Gador; Aliseda, Alberto

    2017-11-01

    Intracranial vascular pathologies are evaluated with angiography, conventional digital subtraction angiography or non-invasive (MRI, CT). Current techniques present limitations on the resolution with which the vessel wall characteristics can be measured, presenting a major challenge to differential diagnostic of cerebral vasculopathies. A new combined approach is presented that incorporates patient-specific image-based CFD models with intracranial vessel-wall MRI (VWMRI). Comparisons of the VWMRI measurements, evaluated for the presence of wall enhancement and thin-walled regions, against CFD metrics such as wall shear stress (WSS), and oscillatory shear index (OSI) are used to understand how the new imaging technique developed can predict the influence of hemodynamics on the deterioration of the aneurysmal wall, leading to rupture. Additionally, histology of each resected aneurysm, evaluated for inflammatory infiltration and wall thickness features, is used to validate the analysis from VWMRI and CFD. This data presents a solid foundation on which to build a new framework for combined VWMRI-CFD to predict unstable wall changes in unruptured intracranial aneurysms, and support clinical monitoring and intervention decisions.

  20. Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results

    International Nuclear Information System (INIS)

    Abolmaali, N.; Schick, C.; Thalhammer, A.; Schmitt, J.; Vogl, T.J.; Langenfeld, M.; Schaechinger, V.; Krahforst, R.; Schulze, T.

    2002-01-01

    Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T 1 -weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T 2 -weighted turbo spin echo sequences and ECG-triggered and fat suppressed T 1 -weighted spin echo sequences before and after iv administration of Gd-DTPA. Findings of the MR images were compared to the results of TEU. Contrast enhancement measurements were performed in normal and thickened vessel wall segments. Results: For the cadaver study a good correlation of the degree of vessel wall thickening and the extent of plaque imaged with the applied MR protocol was found. Tissue characterisation was limited due to post mortem changes. In vivo ECG-triggered T 1 -weighted images showed good correlation to TEU in terms of vessel wall thickness and plaque extension as verified by means of consensus reading. Differentiation of the plaque components fat, calcium and fibrous tissue was possible. In thickened aortic wall segments and fibrous caps a mean contrast enhancement of 50.4%±23.5% was measurable while normal wall segments showed an enhancement of 6.7%±3.1%. (orig.) [de

  1. SCF analysis of a pressurized vessel-nozzle intersection with wall thinning damage

    International Nuclear Information System (INIS)

    Qadir, M.; Redekop, D.

    2009-01-01

    A three-dimensional finite element analysis is carried out of a pressurized vessel-nozzle intersection (tee joint), with wall thinning damage. A convergence-validation study is first carried out for undamaged intersections, in which comparisons are made with previously published work for the stress concentration factor (SCF), and good agreement is observed. A study is then carried out for specific tee joints to examine the effect on the SCF of varying the extent of the wall thinning damage. Finally, a parametric study is conducted in which the SCF is computed for a wide range of tee joints, initially considered undamaged, and then with wall thinning damage.

  2. Development of automated welding process for field fabrication of thick walled pressure vessels

    International Nuclear Information System (INIS)

    Schneider, U.A.

    Research on automatic welding processes for the fabrication of thick-walled pressure vessels continued. A literature review on the subject was completed. A laboratory study of criteria for judging acceptable root parameters continued. Equipment for a demonstration facility to test the components and processes of the automated welding system has been specified and is being obtained

  3. Recovery process of wall condition in KSTAR vacuum vessel after temporal machine-vent for repair

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kwang Pyo, E-mail: kpkim@nfri.er.ke; Hong, Suk-Ho; Lee, Hyunmyung; Song, Jae-in; Jung, Nam-Yong; Lee, Kunsu; Chu, Yong; Kim, Hakkun; Park, Kaprai; Oh, Yeong-Kook

    2015-10-15

    Highlights: • Efforts have been made to obtain vacuum condition that is essential for the plasma experiments. • For example, the vacuum vessel should be vented to repair in-vessel components such as diagnostic shutter, and PFC damaged by high energy plasma. • Here, we present the recovery process of wall condition in KSTAR after temporal machine-vent for repair. • It is found that an acceptable vacuum condition has been achieved only by plasma based wall conditioning techniques such as baking, GDC, and boronization. • This study was that the proper recovering method of the vacuum condition should be developed according to the severity of the accident. - Abstract: Efforts have been made to obtain vacuum condition that is essential for the plasma experiments. Under certain situations, for example, the vacuum vessel should be vented to repair in-vessel components such as diagnostic shutter, exchange of window for diagnostic equipment, and PFC damaged by high energy plasma. For the quick restart of the campaign, a recovery process was established to make the vacuum condition acceptable for the plasma experiment. In this paper, we present the recovery process of wall condition in KSTAR after temporal machine-vent for repair. It is found that an acceptable vacuum condition has been achieved only by plasma based wall conditioning techniques such as baking, GDC, and boronization. This study was that the proper recovering method of the vacuum condition should be developed according to the severity of the accident.

  4. Development of automated welding process for field fabrication of thick walled pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, U A

    1981-01-01

    Research on automatic welding processes for the fabrication of thick-walled pressure vessels continued. A literature review on the subject was completed. A laboratory study of criteria for judging acceptable root parameters continued. Equipment for a demonstration facility to test the components and processes of the automated welding system has been specified and is being obtained. (LCL)

  5. Transient temperature and stress distributions in the pressure vessel's wall of a nuclear reactor

    International Nuclear Information System (INIS)

    Silva, G.A. da

    1979-01-01

    In order to calculate the temperature distribution in a reactor vessel wall which is under the effect of gamma radiation originated in the reactor core, a numerical solution is proposed. This problem may arise from a reactor cooling pump failure .The thermal stresses are also calculated. (Author) [pt

  6. Effects of X-irradiation on artificial blood vessel wall degradation by invasive tumor cells

    International Nuclear Information System (INIS)

    Heisel, M.A.; Laug, W.E.; Stowe, S.M.; Jones, P.A.

    1984-01-01

    Artificial vessel wall cultures, constructed by growing arterial endothelial cells on preformed layers of rat smooth muscle cells, were used to evaluate the effects of X-irradiation on tumor cell-induced tissue degradation. Bovine endothelial cells had radiation sensitivities similar to those of rat smooth muscle cells. Preirradiation of smooth muscle cells, before the addition of human fibrosarcoma (HT 1080) cells, did not increase the rate of degradation and destruction by the invasive cells. However, the degradation rate was decreased if the cultures were irradiated after the addition of HT 1080 cells. The presence of bovine endothelial cells markedly inhibited the destructive abilities of fibrosarcoma cells, but preirradiation of artificial vessel walls substantially decreased their capabilities to resist HT 1080-induced lysis. These findings suggest that the abilities of blood vessels to limit extravasation may be compromised by ionizing radiation

  7. Reactor pressure vessel failure probability following through-wall cracks due to pressurized thermal shock events

    International Nuclear Information System (INIS)

    Simonen, F.A.; Garnich, M.R.; Simonen, E.P.; Bian, S.H.; Nomura, K.K.; Anderson, W.E.; Pedersen, L.T.

    1986-04-01

    A fracture mechanics model was developed at the Pacific Northwest Laboratory (PNL) to predict the behavior of a reactor pressure vessel following a through-wall crack that occurs during a pressurized thermal shock (PTS) event. This study, which contributed to a US Nuclear Regulatory Commission (NRC) program to study PTS risk, was coordinated with the Integrated Pressurized Thermal Shock (IPTS) Program at Oak Ridge National Laboratory (ORNL). The PNL fracture mechanics model uses the critical transients and probabilities of through-wall cracks from the IPTS Program. The PNL model predicts the arrest, reinitiation, and direction of crack growth for a postulated through-wall crack and thereby predicts the mode of vessel failure. A Monte-Carlo type of computer code was written to predict the probabilities of the alternative failure modes. This code treats the fracture mechanics properties of the various welds and plates of a vessel as random variables. Plant-specific calculations were performed for the Oconee-1, Calvert Cliffs-1, and H.B. Robinson-2 reactor pressure vessels for the conditions of postulated transients. The model predicted that 50% or more of the through-wall axial cracks will turn to follow a circumferential weld. The predicted failure mode is a complete circumferential fracture of the vessel, which results in a potential vertically directed missile consisting of the upper head assembly. Missile arrest calculations for the three nuclear plants predict that such vertical missiles, as well as all potential horizontally directed fragmentation type missiles, will be confined to the vessel enclosre cavity. The PNL failure mode model is recommended for use in future evaluations of other plants, to determine the failure modes that are most probable for postulated PTS events

  8. Role of Outgassing of ITER Vacuum Vessel In-Wall Shielding Materials in Leak Detection of ITER Vacuum Vessel

    Science.gov (United States)

    Maheshwari, A.; Pathak, H. A.; Mehta, B. K.; Phull, G. S.; Laad, R.; Shaikh, M. S.; George, S.; Joshi, K.; Khan, Z.

    2017-04-01

    ITER Vacuum Vessel is a torus-shaped, double wall structure. The space between the double walls of the VV is filled with In-Wall Shielding Blocks (IWS) and Water. The main purpose of IWS is to provide neutron shielding during ITER plasma operation and to reduce ripple of Toroidal Magnetic Field (TF). Although In-Wall Shield Blocks (IWS) will be submerged in water in between the walls of the ITER Vacuum Vessel (VV), Outgassing Rate (OGR) of IWS materials plays a significant role in leak detection of Vacuum Vessel of ITER. Thermal Outgassing Rate of a material critically depends on the Surface Roughness of material. During leak detection process using RGA equipped Leak detector and tracer gas Helium, there will be a spill over of mass 3 and mass 2 to mass 4 which creates a background reading. Helium background will have contribution of Hydrogen too. So it is necessary to ensure the low OGR of Hydrogen. To achieve an effective leak test it is required to obtain a background below 1 × 10-8 mbar 1 s-1 and hence the maximum Outgassing rate of IWS Materials should comply with the maximum Outgassing rate required for hydrogen i.e. 1 x 10-10 mbar 1 s-1 cm-2 at room temperature. As IWS Materials are special materials developed for ITER project, it is necessary to ensure the compliance of Outgassing rate with the requirement. There is a possibility of diffusing the gasses in material at the time of production. So, to validate the production process of materials as well as manufacturing of final product from this material, three coupons of each IWS material have been manufactured with the same technique which is being used in manufacturing of IWS blocks. Manufacturing records of these coupons have been approved by ITER-IO (International Organization). Outgassing rates of these coupons have been measured at room temperature and found in acceptable limit to obtain the required Helium Background. On the basis of these measurements, test reports have been generated and got

  9. Protective interior wall and attaching means for a fusion reactor vacuum vessel

    International Nuclear Information System (INIS)

    Phelps, R.D.; Upham, G.A.; Anderson, P.M.

    1988-01-01

    A protective wall for the interior surface of a fusion reactor vessel wall is described comprising: an array of plates, each plate of the array including a main body section, a pair of edge sections bent at an angle with respect to the main body section, and a pair of flange-like end sections each having protruding sections with cut-aways therein, the protruding sections of the flange-like end sections extending in a direction substantially parallel to the main body section; and means operatively associated with the protruding sections of the flange-like end sections of the plates for mounting the array of plates to an associated vessel wall to be protected

  10. Design, fabrication and test of double-wall vacuum vessel for JT-60U

    International Nuclear Information System (INIS)

    Uchikawa, Takashi; Ioki, Kimihiro; Ninomiya, Hiromasa.

    1994-01-01

    A double-wall vacuum vessel was designed and fabricated for JT-60U (an upgraded machine of JT-60), which has a plasma current up to 6 MA and a large plasma volume (100 m 3 ). A new concept of Inconel 625 all-welded structure was adopted to the vessel, that comprises an inner plate, square tubes and an outer plate. The vacuum vessel with a multi-arc D-shaped cross section was fabricated by using hot-sizing press. The electromagnetic and structural analysis has been performed for plasma disruption loads. Dynamic responses of the vessel were measured during plasma disruptions, and the observed displacement had a good agreement with the result of FEM analysis. (author)

  11. The design of lifting attachments for the erection of large diameter and heavy wall pressure vessels

    International Nuclear Information System (INIS)

    Antalffy, Leslie P.; Miller, George A.; Kirkpatrick, Kenneth D.; Rajguru, Anil; Zhu, Yong

    2016-01-01

    Lifting attachments for the erection of large diameter and heavy wall pressure vessels require special consideration to ensure that their attachment to their vessel shells or heads do not overstress the vessel during the erection process when lifting these from grade onto their respective foundations. Today, in refinery and petrochemical services, large diameter vessels with diameters ranging up to 15 m and reactors with lifting weights in the range of 700–1400 tons are not uncommon. In today's fabrication market, these vessels may be purchased and fabricated in shops dispersed globally and will require unique equipment for their safe handling, transportation and subsequent erection. The challenge is to design the lifting attachments in such a manner that the attachments provide a safe, cost effective and effective solution based upon the limitations of the job site lift equipment available for erection. Such equipment for the transportation and subsequent lifting of large diameter and heavy wall pressure equipment is usually scarce and quite expensive. Planning ahead, well in advance of the lift date is almost a mandatory requirement. Usually, the specific parameters of the vessel to be lifted and the lifting equipment available at the site will dictate the type of lifting attachments to be designed for the vessel. Once the type of vessel attachment has been chosen, careful consideration must be given to the design of attachments to the pressure vessel in consideration to ensure that the vessel and lifting components are not overstressed during the lifting process. The paper also discusses different types of lifting attachments that may be attached to each end of the vessel either by bolting or welding and discusses the pros and cons of each. The paper also provides an example of a finite element analysis (FEA) of a top nozzle, a FEA of a pair of lifting trunnions and a FEA of welded on lifting lugs for buried pipe. The purpose of the paper is to outline the

  12. Contribution of the different erosion processes to material release from the vessel walls of fusion devices during plasma operation

    International Nuclear Information System (INIS)

    Behrisch, R.

    2002-01-01

    In high temperature plasma experiments several processes contribute to erosion and loss of material from the vessel walls. This material may enter the plasma edge and the central plasma where it acts as impurities. It will finally be re-deposited at other wall areas. These erosion processes are: evaporation due to heating of wall areas. At very high power deposition evaporation may become very large, which has been named ''blooming''. Large evaporation and melting at some areas of the vessel wall surface may occur during heat pulses, as observed in plasma devices during plasma disruptions. At tips on the vessel walls and/or hot spots on the plasma exposed solid surfaces electrical arcs between the plasma and the vessel wall may ignite. They cause the release of ions, atoms and small metal droplets, or of carbon dust particles. Finally, atoms from the vessel walls are removed by physical and chemical sputtering caused by the bombardment of the vessel walls with ions as well as energetic neutral hydrogen atoms from the boundary plasma. All these processes have been, and are, observed in today's plasma experiments. Evaporation can in principle be controlled by very effective cooling of the wall tiles, arcing is reduced by very stable plasma operation, and sputtering by ions can be reduced by operating with a cold plasma in front of the vessel walls. However, sputtering by energetic neutrals, which impinge on all areas of the vessel walls, is likely to be the most critical process because ions lost from the plasma recycle as neutrals or have to be refuelled by neutrals leading to the charge exchange processes in the plasma. In order to quantify the wall erosion, ''materials factors'' (MF) have been introduced in the following for the different erosion processes. (orig.)

  13. Variable impact of CSF flow suppression on quantitative 3.0T intracranial vessel wall measurements.

    Science.gov (United States)

    Cogswell, Petrice M; Siero, Jeroen C W; Lants, Sarah K; Waddle, Spencer; Davis, L Taylor; Gilbert, Guillaume; Hendrikse, Jeroen; Donahue, Manus J

    2018-03-31

    Flow suppression techniques have been developed for intracranial (IC) vessel wall imaging (VWI) and optimized using simulations; however, simulation results may not translate in vivo. To evaluate experimentally how IC vessel wall and lumen measurements change in identical subjects when evaluated using the most commonly available blood and cerebrospinal fluid (CSF) flow suppression modules and VWI sequences. Prospective. Healthy adults (n = 13; age = 37 ± 15 years) were enrolled. A 3.0T 3D T 1 /proton density (PD)-weighted turbo-spin-echo (TSE) acquisition with post-readout anti-driven equilibrium module, with and without Delay-Alternating-with-Nutation-for-Tailored-Excitation (DANTE) was applied. DANTE flip angle (8-12°) and TSE refocusing angle (sweep = 40-120° or 50-120°) were varied. Basilar artery and internal carotid artery (ICA) wall thicknesses, CSF signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal ratio (SR) were assessed. Measurements were made by two readers (radiology resident and board-certified neuroradiologist). A Wilcoxon signed-rank test was applied with corrected two-sided P CSF suppression. Addition of the DANTE preparation reduced CSF SNR from 17.4 to 6.7, thereby providing significant (P CSF suppression. The DANTE preparation also resulted in a significant (P CSF CNR improvement (P = 0.87). There was a trend for a difference in blood SNR with vs. without DANTE (P = 0.05). The outer vessel wall diameter and wall thickness values were lower (P CSF suppression and CNR of the approaches evaluated. However, improvements are heterogeneous, likely owing to intersubject vessel pulsatility and CSF flow variations, which can lead to variable flow suppression efficacy in these velocity-dependent modules. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  14. JSC technician checks STS-44 DSO 316 bioreactor and rotating wall vessel hdwr

    Science.gov (United States)

    1991-01-01

    JSC technician Tacey Prewitt checks the progress on a bioreactor experiment in JSC's Life Sciences Laboratory Bldg 37 biotechnology laboratory. Similar hardware is scheduled for testing aboard Atlantis, Orbiter Vehicle (OV) 104, during STS-44. Detailed Supplementary Objective (DSO) 316 Bioreactor/Flow and Particle Trajectory in Microgravity will checkout the rotating wall vessel hardware and hopefully will confirm researchers' theories and calculations about how flow fields work in space. Plastic beads of various sizes rather than cell cultures are being flown in the vessel for the STS-44 test.

  15. Influence of acquired obesity on coronary vessel wall late gadolinium enhancement in discordant monozygote twins

    Energy Technology Data Exchange (ETDEWEB)

    Makowski, Marcus R. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Wellcome Trust and EPSRC Medical Engineering Centre, London (United Kingdom); King' s College London, BHF Centre of Excellence, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre, London (United Kingdom); Charite-Universitaetsmedizin, Department of Radiology, Berlin (Germany); Jansen, Christian H.P. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Ebersberger, Ullrich; Spector, Tim D. [Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Schaeffter, Tobias; Razavi, Reza [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Wellcome Trust and EPSRC Medical Engineering Centre, London (United Kingdom); King' s College London, BHF Centre of Excellence, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre, London (United Kingdom); Mangino, Massimo [King' s College London, Department of Twin Research and Genetic Epidemiology, London (United Kingdom); National Institute for Health Research (NIHR) Biomedical Research Centre at Guy' s and St. Thomas' Foundation Trust, London (United Kingdom); Botnar, Rene M. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Wellcome Trust and EPSRC Medical Engineering Centre, London (United Kingdom); King' s College London, BHF Centre of Excellence, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre, London (United Kingdom); Greil, Gerald F. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Wellcome Trust and EPSRC Medical Engineering Centre, London (United Kingdom); King' s College London, BHF Centre of Excellence, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre, London (United Kingdom)

    2017-11-15

    The aim of this study was to investigate the impact of BMI on late gadolinium enhancement (LGE) of the coronary artery wall in identical monozygous twins discordant for BMI. Coronary LGE represents a useful parameter for the detection and quantification of atherosclerotic coronary vessel wall disease. Thirteen monozygote female twin pairs (n = 26) with significantly different BMIs (>1.6 kg/m2) were recruited out of >10,000 twin pairs (TwinsUK Registry). A coronary 3D-T2prep-TFE MR angiogram and 3D-IR-TFE vessel wall scan were performed prior to and following the administration of 0.2 mmol/kg of Gd-DTPA on a 1.5 T MR scanner. The number of enhancing coronary segments and contrast to noise ratios (CNRs) of the coronary wall were quantified. An increase in BMI was associated with an increased number of enhancing coronary segments (5.3 ± 1.5 vs. 3.5 ± 1.6, p < 0.0001) and increased coronary wall enhancement (6.1 ± 1.1 vs. 4.8 ± 0.9, p = 0.0027) compared to matched twins with lower BMI. This study in monozygous twins indicates that acquired factors predisposing to obesity, including lifestyle and environmental factors, result in increased LGE of the coronary arteries, potentially reflecting an increase in coronary atherosclerosis in this female study population. (orig.)

  16. Influence of acquired obesity on coronary vessel wall late gadolinium enhancement in discordant monozygote twins

    International Nuclear Information System (INIS)

    Makowski, Marcus R.; Jansen, Christian H.P.; Ebersberger, Ullrich; Spector, Tim D.; Schaeffter, Tobias; Razavi, Reza; Mangino, Massimo; Botnar, Rene M.; Greil, Gerald F.

    2017-01-01

    The aim of this study was to investigate the impact of BMI on late gadolinium enhancement (LGE) of the coronary artery wall in identical monozygous twins discordant for BMI. Coronary LGE represents a useful parameter for the detection and quantification of atherosclerotic coronary vessel wall disease. Thirteen monozygote female twin pairs (n = 26) with significantly different BMIs (>1.6 kg/m2) were recruited out of >10,000 twin pairs (TwinsUK Registry). A coronary 3D-T2prep-TFE MR angiogram and 3D-IR-TFE vessel wall scan were performed prior to and following the administration of 0.2 mmol/kg of Gd-DTPA on a 1.5 T MR scanner. The number of enhancing coronary segments and contrast to noise ratios (CNRs) of the coronary wall were quantified. An increase in BMI was associated with an increased number of enhancing coronary segments (5.3 ± 1.5 vs. 3.5 ± 1.6, p < 0.0001) and increased coronary wall enhancement (6.1 ± 1.1 vs. 4.8 ± 0.9, p = 0.0027) compared to matched twins with lower BMI. This study in monozygous twins indicates that acquired factors predisposing to obesity, including lifestyle and environmental factors, result in increased LGE of the coronary arteries, potentially reflecting an increase in coronary atherosclerosis in this female study population. (orig.)

  17. Vessel wall and indium-111-labelled platelet response to carotid endarterectomy

    International Nuclear Information System (INIS)

    Lusby, R.J.; Ferrell, L.D.; Englestad, B.L.; Price, D.C.; Lipton, M.J.; Stoney, R.J.

    1983-01-01

    Postendarterectomy platelet deposition and thrombus formation may play an important role not only in vessel wall healing but also in the small incidence of postoperative cerebral ischemia and postoperative stenosis. A study has been performed using a canine model to investigate the healing response to carotid endarterectomy and the validity of an in vivo indium-111 (In-111) radiotracer technique in the assessment of postendarterectomy deposition of autologous labelled platelets. Sixteen endarterectomized carotid arteries showed uptake of autologous In-111 platelets immediately after infusion, reaching a maximum by 1 hour with little increase at 24 or 48 hours. No uptake was seen in ten control vessels following platelet infusion (P less than 0.05). At autopsy, seven vessels were demonstrated to have In-111 platelet deposition immediately prior to sacrifice of the animals. Postmortem scanning confirmed the localization to the vessel lumens, and microscopy revealed thrombus formation with or without partial endothelialization. Complete reendothelialization had occurred in the vessels that failed to show platelet deposition. Delayed healing was associated with continuing platelet deposition, excessive thrombus formation, and luminal stenosis. Arteriotomy closure with a vein patch altered the healing characteristics of the vessel with segmental thrombus formation over the vein patch. A preliminary study of the postendarterectomy in vivo In-111 platelet response in humans demonstrated platelet deposition that was not influenced by the administration of antiplatelet drugs at currently prescribed levels

  18. Acoustic emission monitoring during hydrotest of a thin wall pressure vessel

    International Nuclear Information System (INIS)

    Fontana, E.; Grugni, G.; Panzani, C.; Pirovano, B.; Possa, G.; Tonolini, F.

    1976-01-01

    Results are presented of the acoustic emission monitoring during hydrotests of a thin wall steel pressure vessel. Location of acoustic sources was based on longitudinal wave front detection. The careful calibration of the three sensors used for acoustic source location was found to be very useful, and allowed an accurate location error analysis. Acoustic emission in the hydrotests was found to be due mainly to stress release in weld seams

  19. Stress analysis of a double-wall vacuum vessel for ITER

    International Nuclear Information System (INIS)

    Conner, D.L.; Williamson, D.E.; Nelson, B.E.

    1991-01-01

    The preliminary structural analyses performed in support of the design of the vacuum vessel for the International Thermonuclear Experimental Reactor (ITER) are described. A thin, double-wall, all-welded structure is the proposed design concept analyzed. The results of the static stress analysis indicate the adequacy of such a structure. The effects of the proposed high-aspect-ratio design configuration on loading and stresses are also discussed. 4 refs., 6 figs., 1 tab

  20. Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla

    Directory of Open Access Journals (Sweden)

    Sebastian Kelle

    2010-01-01

    Full Text Available Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd contrast administration and coronary vessel wall enhancement (LGE detected by 3T magnetic resonance imaging (MRI in healthy subjects and patients with coronary artery disease (CAD. Materials and Methods. Four healthy subjects (4 men, mean age 29  ±  3 years and eleven CAD patients (6 women, mean age 61±10 years were studied on a commercial 3.0 Tesla (T whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands. T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd (0.1 mmol/kg Gd-DTPA. Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3% segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0% and at time-interval 3, 29 of 39 evaluable segments (74.4% were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30–45 minutes after administration of the contrast agent.

  1. High-resolution vessel wall MRI for the evaluation of intracranial atherosclerotic disease

    Energy Technology Data Exchange (ETDEWEB)

    De Havenon, Adam [University of Utah, Department of Neurology, Salt Lake City, UT (United States); Mossa-Basha, Mahmud [University of Washington, Department of Radiology, Seattle, WA (United States); Shah, Lubdha; Kim, Seong-Eun; Parker, Dennis; McNally, J.S. [University of Utah, Department of Radiology, Salt Lake City, UT (United States); Park, Min [University of Utah, Department of Neurosurgery, Salt Lake City, UT (United States)

    2017-12-15

    High-resolution vessel wall MRI (vwMRI) of the intracranial arteries is an emerging diagnostic imaging technique with the goal of evaluating vascular pathology. vwMRI sequences have high spatial resolution and directly image the vessel wall by suppressing blood signal. With vwMRI, it is possible to identify distinct morphologic and enhancement patterns of atherosclerosis that can provide important information about stroke etiology and recurrence risk. We present a review of vwMRI research in relation to intracranial atherosclerosis, with a focus on the relationship between ischemic stroke and atherosclerotic plaque T1 post-contrast enhancement or plaque/vessel wall morphology. The goal of this review is to provide readers with the most current understanding of the reliability, incidence, and importance of specific vwMRI findings in intracranial atherosclerosis, to guide their interpretation of vwMRI research, and help inform clinical interpretation of vwMRI. We will also provide a translational perspective on the existing vwMRI literature and insight into future vwMRI research questions and objectives. With increased use of high field strength MRI, powerful gradients, and improved pulse sequences, vwMRI will become standard-of-care in the diagnosis and prognosis of patients with cerebrovascular disease, making a firm grasp of its strengths and weakness important for neuroimagers. (orig.)

  2. Regulation of cellular communication by signaling microdomains in the blood vessel wall.

    Science.gov (United States)

    Billaud, Marie; Lohman, Alexander W; Johnstone, Scott R; Biwer, Lauren A; Mutchler, Stephanie; Isakson, Brant E

    2014-01-01

    It has become increasingly clear that the accumulation of proteins in specific regions of the plasma membrane can facilitate cellular communication. These regions, termed signaling microdomains, are found throughout the blood vessel wall where cellular communication, both within and between cell types, must be tightly regulated to maintain proper vascular function. We will define a cellular signaling microdomain and apply this definition to the plethora of means by which cellular communication has been hypothesized to occur in the blood vessel wall. To that end, we make a case for three broad areas of cellular communication where signaling microdomains could play an important role: 1) paracrine release of free radicals and gaseous molecules such as nitric oxide and reactive oxygen species; 2) role of ion channels including gap junctions and potassium channels, especially those associated with the endothelium-derived hyperpolarization mediated signaling, and lastly, 3) mechanism of exocytosis that has considerable oversight by signaling microdomains, especially those associated with the release of von Willebrand factor. When summed, we believe that it is clear that the organization and regulation of signaling microdomains is an essential component to vessel wall function.

  3. Regulation of Cellular Communication by Signaling Microdomains in the Blood Vessel Wall

    Science.gov (United States)

    Billaud, Marie; Lohman, Alexander W.; Johnstone, Scott R.; Biwer, Lauren A.; Mutchler, Stephanie; Isakson, Brant E.

    2014-01-01

    It has become increasingly clear that the accumulation of proteins in specific regions of the plasma membrane can facilitate cellular communication. These regions, termed signaling microdomains, are found throughout the blood vessel wall where cellular communication, both within and between cell types, must be tightly regulated to maintain proper vascular function. We will define a cellular signaling microdomain and apply this definition to the plethora of means by which cellular communication has been hypothesized to occur in the blood vessel wall. To that end, we make a case for three broad areas of cellular communication where signaling microdomains could play an important role: 1) paracrine release of free radicals and gaseous molecules such as nitric oxide and reactive oxygen species; 2) role of ion channels including gap junctions and potassium channels, especially those associated with the endothelium-derived hyperpolarization mediated signaling, and lastly, 3) mechanism of exocytosis that has considerable oversight by signaling microdomains, especially those associated with the release of von Willebrand factor. When summed, we believe that it is clear that the organization and regulation of signaling microdomains is an essential component to vessel wall function. PMID:24671377

  4. High-resolution vessel wall MRI for the evaluation of intracranial atherosclerotic disease

    International Nuclear Information System (INIS)

    De Havenon, Adam; Mossa-Basha, Mahmud; Shah, Lubdha; Kim, Seong-Eun; Parker, Dennis; McNally, J.S.; Park, Min

    2017-01-01

    High-resolution vessel wall MRI (vwMRI) of the intracranial arteries is an emerging diagnostic imaging technique with the goal of evaluating vascular pathology. vwMRI sequences have high spatial resolution and directly image the vessel wall by suppressing blood signal. With vwMRI, it is possible to identify distinct morphologic and enhancement patterns of atherosclerosis that can provide important information about stroke etiology and recurrence risk. We present a review of vwMRI research in relation to intracranial atherosclerosis, with a focus on the relationship between ischemic stroke and atherosclerotic plaque T1 post-contrast enhancement or plaque/vessel wall morphology. The goal of this review is to provide readers with the most current understanding of the reliability, incidence, and importance of specific vwMRI findings in intracranial atherosclerosis, to guide their interpretation of vwMRI research, and help inform clinical interpretation of vwMRI. We will also provide a translational perspective on the existing vwMRI literature and insight into future vwMRI research questions and objectives. With increased use of high field strength MRI, powerful gradients, and improved pulse sequences, vwMRI will become standard-of-care in the diagnosis and prognosis of patients with cerebrovascular disease, making a firm grasp of its strengths and weakness important for neuroimagers. (orig.)

  5. Role of 3.0 T MR vessel wall imaging for identifying the activity of takayasu arteritis

    International Nuclear Information System (INIS)

    Liu Xiaosheng; Xu Jianrong; Zhao Huilin; Cheng Fang; Lu Qing; Yao Qiuying

    2010-01-01

    Objective: To analyze and explore the value of 3 T high resolution magnetic resonance vessel wall imaging for identifying the activity of Takayasu arteritis. Methods: Twenty-six consecutive patients with Takayasu arteritis underwent 3.0 T high resolution MR vessel wall imaging on supraortic vessels (according to the classification of Lupi-Herrea, type I and III were included). Sixteen patients were in active phase and 10 in inactive phase based on the Kerr criteria. The MR vessel wall imaging appearances of Takayasu arteritis were compared between the active phase and inactive phase cases. Results: Wall thickening was demonstrated in all involved arteries. There were statistically significant differences between active phase and inactive phase cases in MR appearances including multi-ring thickening of vessel wall (75/80 and 18/50), arterial inner wail enhancement (50/80 and 19/50), obscurity of perivascular fat (55/80 and 18/50, X 2 =50.39, 7.41, 13.40, P<0.01). There was also a statistically significant difference in the thickness of carotid artery wall between the two groups [ (3.8 ± 0.2) mm vs (2.5 ± 0.8) mm]. Conclusion: 3 T high resolution MR vessel wall imaging is valuable for identifying the activity of Takayasu arteritis. (authors)

  6. Primary Metabolism during Biosynthesis of Secondary Wall Polymers of Protoxylem Vessel Elements1[OPEN

    Science.gov (United States)

    Morisaki, Keiko; Sawada, Yuji; Sano, Ryosuke; Yamamoto, Atsushi; Kurata, Tetsuya; Suzuki, Shiro; Matsuda, Mami; Hasunuma, Tomohisa; Hirai, Masami Yokota

    2016-01-01

    Xylem vessels, the water-conducting cells in vascular plants, undergo characteristic secondary wall deposition and programmed cell death. These processes are regulated by the VASCULAR-RELATED NAC-DOMAIN (VND) transcription factors. Here, to identify changes in metabolism that occur during protoxylem vessel element differentiation, we subjected tobacco (Nicotiana tabacum) BY-2 suspension culture cells carrying an inducible VND7 system to liquid chromatography-mass spectrometry-based wide-target metabolome analysis and transcriptome analysis. Time-course data for 128 metabolites showed dynamic changes in metabolites related to amino acid biosynthesis. The concentration of glyceraldehyde 3-phosphate, an important intermediate of the glycolysis pathway, immediately decreased in the initial stages of cell differentiation. As cell differentiation progressed, specific amino acids accumulated, including the shikimate-related amino acids and the translocatable nitrogen-rich amino acid arginine. Transcriptome data indicated that cell differentiation involved the active up-regulation of genes encoding the enzymes catalyzing fructose 6-phosphate biosynthesis from glyceraldehyde 3-phosphate, phosphoenolpyruvate biosynthesis from oxaloacetate, and phenylalanine biosynthesis, which includes shikimate pathway enzymes. Concomitantly, active changes in the amount of fructose 6-phosphate and phosphoenolpyruvate were detected during cell differentiation. Taken together, our results show that protoxylem vessel element differentiation is associated with changes in primary metabolism, which could facilitate the production of polysaccharides and lignin monomers and, thus, promote the formation of the secondary cell wall. Also, these metabolic shifts correlate with the active transcriptional regulation of specific enzyme genes. Therefore, our observations indicate that primary metabolism is actively regulated during protoxylem vessel element differentiation to alter the cell’s metabolic

  7. Freezing resistance in Patagonian woody shrubs: the role of cell wall elasticity and stem vessel size.

    Science.gov (United States)

    Zhang, Yong-Jiang; Bucci, Sandra J; Arias, Nadia S; Scholz, Fabian G; Hao, Guang-You; Cao, Kun-Fang; Goldstein, Guillermo

    2016-08-01

    Freezing resistance through avoidance or tolerance of extracellular ice nucleation is important for plant survival in habitats with frequent subzero temperatures. However, the role of cell walls in leaf freezing resistance and the coordination between leaf and stem physiological processes under subzero temperatures are not well understood. We studied leaf and stem responses to freezing temperatures, leaf and stem supercooling, leaf bulk elastic modulus and stem xylem vessel size of six Patagonian shrub species from two sites (plateau and low elevation sites) with different elevation and minimum temperatures. Ice seeding was initiated in the stem and quickly spread to leaves, but two species from the plateau site had barriers against rapid spread of ice. Shrubs with xylem vessels smaller in diameter had greater stem supercooling capacity, i.e., ice nucleated at lower subzero temperatures. Only one species with the lowest ice nucleation temperature among all species studied exhibited freezing avoidance by substantial supercooling, while the rest were able to tolerate extracellular freezing from -11.3 to -20 °C. Leaves of species with more rigid cell walls (higher bulk elastic modulus) could survive freezing to lower subzero temperatures, suggesting that rigid cell walls potentially reduce the degree of physical injury to cell membranes during the extracellular freezing and/or thaw processes. In conclusion, our results reveal the temporal-spatial ice spreading pattern (from stem to leaves) in Patagonian shrubs, and indicate the role of xylem vessel size in determining supercooling capacity and the role of cell wall elasticity in determining leaf tolerance of extracellular ice formation. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Impact of vessel wall lesions and vascular stenoses on cerebrovascular reactivity in patients with intracranial stenotic disease

    NARCIS (Netherlands)

    Cogswell, Petrice M; Davis, Taylor L; Strother, Megan K; Faraco, Carlos C; Scott, Allison O; Jordan, Lori C; Fusco, Matthew R; Frederick, Blaise deB; Hendrikse, Jeroen; Donahue, Manus J

    2017-01-01

    PURPOSE: To compare cerebrovascular reactivity (CVR) and CVR lagtimes in flow territories perfused by vessels with vs. without proximal arterial wall disease and/or stenosis, separately in patients with atherosclerotic and nonatherosclerotic (moyamoya) intracranial stenosis. MATERIALS AND METHODS:

  9. Positive association between increased popliteal artery vessel wall thickness and generalized osteoarthritis: is OA also part of the metabolic syndrome?

    International Nuclear Information System (INIS)

    Kornaat, Peter R.; Sharma, Ruby; Geest, Rob J. van der; Lamb, Hildo J.; Bloem, Johan L.; Watt, Iain; Kloppenburg, Margreet; Hellio le Graverand, Marie-Pierre

    2009-01-01

    The purpose of the study was to determine if a positive association exists between arterial vessel wall thickness and generalized osteoarthritis (OA). Our hypothesis is that generalized OA is another facet of the metabolic syndrome. The medical ethical review board of our institution approved the study. Written informed consent was obtained from each patient prior to the study. Magnetic resonance (MR) images of the knee were obtained in 42 patients who had been diagnosed with generalized OA at multiple joint sites. Another 27 MR images of the knee were obtained from a matched normal (non-OA) reference population. Vessel wall thickness of the popliteal artery was quantitatively measured by dedicated software. Linear regression models were used to investigate the association between vessel wall thickness and generalized OA. Adjustments were made for age, sex, and body mass index (BMI). Confidence intervals (CI) were computed at the 95% level and a significance level of α = 0.05 was used. Patients in the generalized OA population had a significant higher average vessel wall thickness than persons from the normal reference population (p ≤ α), even when correction was made for sex, age, and BMI. The average vessel wall thickness of the popliteal artery was 1.09 mm in patients with generalized OA, and 0.96 mm in the matched normal reference population. The association found between increased popliteal artery vessel wall thickness and generalized osteoarthritis suggests that generalized OA might be another facet of the metabolic syndrome. (orig.)

  10. Positive association between increased popliteal artery vessel wall thickness and generalized osteoarthritis: is OA also part of the metabolic syndrome?

    Energy Technology Data Exchange (ETDEWEB)

    Kornaat, Peter R.; Sharma, Ruby; Geest, Rob J. van der; Lamb, Hildo J.; Bloem, Johan L.; Watt, Iain [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Kloppenburg, Margreet [Leiden University Medical Center, Department of Rheumatology, Leiden (Netherlands); Hellio le Graverand, Marie-Pierre [Pfizer Global Research and Development, New London, CT (United States)

    2009-12-15

    The purpose of the study was to determine if a positive association exists between arterial vessel wall thickness and generalized osteoarthritis (OA). Our hypothesis is that generalized OA is another facet of the metabolic syndrome. The medical ethical review board of our institution approved the study. Written informed consent was obtained from each patient prior to the study. Magnetic resonance (MR) images of the knee were obtained in 42 patients who had been diagnosed with generalized OA at multiple joint sites. Another 27 MR images of the knee were obtained from a matched normal (non-OA) reference population. Vessel wall thickness of the popliteal artery was quantitatively measured by dedicated software. Linear regression models were used to investigate the association between vessel wall thickness and generalized OA. Adjustments were made for age, sex, and body mass index (BMI). Confidence intervals (CI) were computed at the 95% level and a significance level of {alpha} = 0.05 was used. Patients in the generalized OA population had a significant higher average vessel wall thickness than persons from the normal reference population (p {<=} {alpha}), even when correction was made for sex, age, and BMI. The average vessel wall thickness of the popliteal artery was 1.09 mm in patients with generalized OA, and 0.96 mm in the matched normal reference population. The association found between increased popliteal artery vessel wall thickness and generalized osteoarthritis suggests that generalized OA might be another facet of the metabolic syndrome. (orig.)

  11. Tearing stability analysis of an axial surface flaw in thick-walled pressure vessels

    International Nuclear Information System (INIS)

    Zahoor, A.; Ghassemi, B.B.

    1991-01-01

    This paper presents two fracture mechanics models for evaluation of an axial surface flaw in pressure vessels. The surface flaw is located on the outside surface of the vessel. The first model assumes yielding of the remaining ligament directly ahead of the flaw. The second model assumes contained yielding ahead of the flaw and uses a linear elastic fracture mechanics solution. The former model is suitable for cases where the combination of material toughness, flaw size, and load is such that initiation of flaw growth follows ligament yielding. The latter model is suitable for low-toughness materials where initiation of crack growth and potential tearing instability may occur prior to the yielding of the ligament. Both models are suitable for thick-walled vessels. The paper discusses the applicability regime for both models. The models are then applied to a test vessel and the predicted failure pressure is compared against the pressure attained in the test. Results show that both models can be applied successfully. In particular, the contained yielding model when used with the plane-stress assumption can give reasonable predictions even for cases that involve yielding of the ligament. (orig.)

  12. Tearing stability analysis of an axial surface flaw in thick-walled pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Ghassemi, B.B. (NOVETECH Corp., Rockville, MD (USA))

    1991-04-01

    This paper presents two fracture mechanics models for evaluation of an axial surface flaw in pressure vessels. The surface flaw is located on the outside surface of the vessel. The first model assumes yielding of the remaining ligament directly ahead of the flaw. The second model assumes contained yielding ahead of the flaw and uses a linear elastic fracture mechanics solution. The former model is suitable for cases where the combination of material toughness, flaw size, and load is such that initiation of flaw growth follows ligament yielding. The latter model is suitable for low-toughness materials where initiation of crack growth and potential tearing instability may occur prior to the yielding of the ligament. Both models are suitable for thick-walled vessels. The paper discusses the applicability regime for both models. The models are then applied to a test vessel and the predicted failure pressure is compared against the pressure attained in the test. Results show that both models can be applied successfully. In particular, the contained yielding model when used with the plane-stress assumption can give reasonable predictions even for cases that involve yielding of the ligament. (orig.).

  13. Applied model of through-wall crack of coolant vessels of WWER-type reactors

    International Nuclear Information System (INIS)

    Petrosyan, V.; Hovakimyan, T.; Vardanyan, M.; Khachatryan, A.; Minasyan, K.

    2010-01-01

    We propose an applied-model of Through-Wall Crack (TWC) for WWER-type units primary vessels. The model allows to simulate the main morphological parameters of real TWC, i.e. length, area of inlet and outlet openings, channel depth and small and large size unevenness of the crack surface. The model can be used for developing and improving the coolant-leak detectors for the primary circuit vessels of WWER-units. Also, it can be used for research of the coolant two-phase leakage phenomenon through narrow cracks/channels and thermo-physical processes in heat-insulation layer of the Main Coolant Piping (MCP) during the leak

  14. Upper and Lower Bound Limit Loads for Thin-Walled Pressure Vessels Used for Aerosol Cans

    Directory of Open Access Journals (Sweden)

    Stephen John Hardy

    2009-01-01

    Full Text Available The elastic compensation method proposed by Mackenzie and Boyle is used to estimate the upper and lower bound limit (collapse loads for one-piece aluminium aerosol cans, which are thin-walled pressure vessels subjected to internal pressure loading. Elastic-plastic finite element predictions for yield and collapse pressures are found using axisymmetric models. However, it is shown that predictions for the elastic-plastic buckling of the vessel base require the use of a full three-dimensional model with a small unsymmetrical imperfection introduced. The finite element predictions for the internal pressure to cause complete failure via collapse fall within the upper and lower bounds. Hence the method, which involves only elastic analyses, can be used in place of complex elastic-plastic finite element analyses when upper and lower bound estimates are adequate for design purposes. Similarly, the lower bound value underpredicts the pressure at which first yield occurs.

  15. A wall-crawling robot for reactor vessel inspection in advanced reactors

    International Nuclear Information System (INIS)

    Spelt, P.F.; Crane, C.; Feng, L.; Abidi, M.; Tosunoglu, S.

    1994-01-01

    A consortium of four universities and the Center for Engineering Systems Advanced Research of the Oak Ridge National Laboratory has designed a prototype wall-crawling robot to perform weld inspection in advanced nuclear reactors. Design efforts for the reactor vessel inspection robot (RVIR) concentrated on the Advanced Liquid Metal Reactor because it presents the most demanding environment in which such a robot must operate. The RVIR consists of a chassis containing two sets of suction cups that can alternately grasp the side of the vessel being inspected, providing both locomotion and steering functions. Sensors include three CCD cameras and a weld inspection device based on new shear-wave technology. The restrictions of the inspection environment presented major challenges to the team. These challenges were met in the prototype, which has been tested in a non-radiation, room-temperature mockup of the robot work environment and shown to perform as expected. (author)

  16. A wall-crawling robot for reactor vessel inspection in advanced reactors

    International Nuclear Information System (INIS)

    Spelt, P.F.; Crane, C.; Feng, L.; Abidi, M.; Tosunoglu, S.

    1994-01-01

    A consortium of four universities and the Center for Engineering Systems Advanced Research of the Oak Ridge National Laboratory has designed a prototype wall-crawling robot to perform weld inspection in advanced nuclear reactors. Design efforts for the reactor vessel inspection robot (RVIR) concentrated on the Advanced Liquid Metal Reactor because it presents the most demanding environment in which such a robot must operate. The RVIR consists of a chassis containing two sets of suction cups that can alternately grasp the side of the vessel being inspected, providing both locomotion and steering functions. Sensors include three CCD cameras and a weld inspection device based on new shear-wave technology. The restrictions of the inspection environment presented major challenges to the team. These challenges were met in the prototype, which has been tested in a non-radiation, room-temperature mockup of the robot work environment and shown to perform as expected

  17. Acoustic emission monitoring during hydrotests of a thin wall pressure vessel

    International Nuclear Information System (INIS)

    Fontana, E.; Grugni, G.; Panzani, C.; Pirovano, B.; Possa, G.; Tonolini, F.

    1975-01-01

    The results are presented of an acoustic emission monitoring performed during hydrotests of a thin wall steel pressure vessel. The location of acoustic sources was based on longitudinal wave front detection. The careful calibration of the three sensors instrumentation system used for acoustic source location was found to be useful, and alllowed an accurate location error analysis. Acoustic emission in the hydrotests was found to be mainly due to stress release in weld seams. (Fontana, E.; Grugni, G.; Panzani, C.; Pirovano, B.; Possa, G.; Tonolini, F.)

  18. Remote through-wall sampling of the Trawsfynydd reactor pressure vessel: an overview

    International Nuclear Information System (INIS)

    Curry, A.; Clayton, R.

    1996-01-01

    This paper summarises the application of robotic equipment for gaining access to and removing through-wall samples from welds of the reactor pressure vessel at Trawsfynydd power station. The environment, which presents hazards due to ionising radiation, radioactive contamination and asbestos bearing materials is described. The means of access, by use of remote vehicles complete with robotic manipulators supported by additional vehicles, is reviewed. The use of Abrasive Water Jet Cutting for sample removal is introduced. The relative advantages and disadvantages of this technique are discussed. (Author)

  19. Carotid Intraplaque Hemorrhage Imaging with Quantitative Vessel Wall T1 Mapping: Technical Development and Initial Experience.

    Science.gov (United States)

    Qi, Haikun; Sun, Jie; Qiao, Huiyu; Chen, Shuo; Zhou, Zechen; Pan, Xinlei; Wang, Yishi; Zhao, Xihai; Li, Rui; Yuan, Chun; Chen, Huijun

    2018-04-01

    Purpose To develop a three-dimensional (3D) high-spatial-resolution time-efficient sequence for use in quantitative vessel wall T1 mapping. Materials and Methods A previously described sequence, simultaneous noncontrast angiography and intraplaque hemorrhage (SNAP) imaging, was extended by introducing 3D golden angle radial k-space sampling (GOAL-SNAP). Sliding window reconstruction was adopted to reconstruct images at different inversion delay times (different T1 contrasts) for voxelwise T1 fitting. Phantom studies were performed to test the accuracy of T1 mapping with GOAL-SNAP against a two-dimensional inversion recovery (IR) spin-echo (SE) sequence. In vivo studies were performed in six healthy volunteers (mean age, 27.8 years ± 3.0 [standard deviation]; age range, 24-32 years; five male) and five patients with atherosclerosis (mean age, 66.4 years ± 5.5; range, 60-73 years; five male) to compare T1 measurements between vessel wall sections (five per artery) with and without intraplaque hemorrhage (IPH). Statistical analyses included Pearson correlation coefficient, Bland-Altman analysis, and Wilcoxon rank-sum test with data permutation by subject. Results Phantom T1 measurements with GOAL-SNAP and IR SE sequences showed excellent correlation (R 2 = 0.99), with a mean bias of -25.8 msec ± 43.6 and a mean percentage error of 4.3% ± 2.5. Minimum T1 was significantly different between sections with IPH and those without it (mean, 371 msec ± 93 vs 944 msec ± 120; P = .01). Estimated T1 of normal vessel wall and muscle were 1195 msec ± 136 and 1117 msec ± 153, respectively. Conclusion High-spatial-resolution (0.8 mm isotropic) time-efficient (5 minutes) vessel wall T1 mapping is achieved by using the GOAL-SNAP sequence. This sequence may yield more quantitative reproducible biomarkers with which to characterize IPH and monitor its progression. © RSNA, 2017.

  20. Vessel wall damage by X-rays and 15 MeV neutrons

    International Nuclear Information System (INIS)

    Aarnoudse, M.W.

    1979-01-01

    In two simple mucopolysaccharide systems, synovial fluid and subcutaneous connective tissue membranes, the degrading effects of 200 kVp X-rays and 15 MeV neutrons is compared. Due to the depolymerization of the mucopolysaccharides the viscosity of synovial fluid decreases and the permeability of the connective tissue membranes for saline increases after irradiation. In both systems a RBE of 0.6 has been found for fast neutrons. The atheromatous changes in the wall of elastic arteries (lipid penetration into the vessel wall and the formation of plaques consisting of large, lipid-filled foam cells) are studied in the carotid arteries of hypercholesterolemic rabbits, two months after irradiating the arteries with different doses of X-rays or neutrons. (Auth.)

  1. Estimation of the radial force on the tokamak vessel wall during fast transient events

    Energy Technology Data Exchange (ETDEWEB)

    Pustovitov, V. D., E-mail: pustovitov-vd@nrcki.ru [National Research Center Kurchatov Institute (Russian Federation)

    2016-11-15

    The radial force balance in a tokamak during fast transient events with a duration much shorter than the resistive time of the vacuum vessel wall is analyzed. The aim of the work is to analytically estimate the resulting integral radial force on the wall. In contrast to the preceding study [Plasma Phys. Rep. 41, 952 (2015)], where a similar problem was considered for thermal quench, simultaneous changes in the profiles and values of the pressure and plasma current are allowed here. Thereby, the current quench and various methods of disruption mitigation used in the existing tokamaks and considered for future applications are also covered. General formulas for the force at an arbitrary sequence or combination of events are derived, and estimates for the standard tokamak model are made. The earlier results and conclusions are confirmed, and it is shown that, in the disruption mitigation scenarios accepted for ITER, the radial forces can be as high as in uncontrolled disruptions.

  2. General and crevice corrosion study of the in-wall shielding materials for ITER vacuum vessel

    Science.gov (United States)

    Joshi, K. S.; Pathak, H. A.; Dayal, R. K.; Bafna, V. K.; Kimihiro, Ioki; Barabash, V.

    2012-11-01

    Vacuum vessel In-Wall Shield (IWS) will be inserted between the inner and outer shells of the ITER vacuum vessel. The behaviour of IWS in the vacuum vessel especially concerning the susceptibility to crevice of shielding block assemblies could cause rapid and extensive corrosion attacks. Even galvanic corrosion may be due to different metals in same electrolyte. IWS blocks are not accessible until life of the machine after closing of vacuum vessel. Hence, it is necessary to study the susceptibility of IWS materials to general corrosion and crevice corrosion under operations of ITER vacuum vessel. Corrosion properties of IWS materials were studied by using (i) Immersion technique and (ii) Electro-chemical Polarization techniques. All the sample materials were subjected to a series of examinations before and after immersion test, like Loss/Gain weight measurement, SEM analysis, and Optical stereo microscopy, measurement of surface profile and hardness of materials. After immersion test, SS 304B4 and SS 304B7 showed slight weight gain which indicate oxide layer formation on the surface of coupons. The SS 430 material showed negligible weight loss which indicates mild general corrosion effect. On visual observation with SEM and Metallography, all material showed pitting corrosion attack. All sample materials were subjected to series of measurements like Open Circuit potential, Cyclic polarization, Pitting potential, protection potential, Critical anodic current and SEM examination. All materials show pitting loop in OC2 operating condition. However, its absence in OC1 operating condition clearly indicates the activity of chloride ion to penetrate oxide layer on the sample surface, at higher temperature. The critical pitting temperature of all samples remains between 100° and 200°C.

  3. Vessel Wall Inflammation of Takayasu Arteritis Detected by Contrast-Enhanced Magnetic Resonance Imaging: Association with Disease Distribution and Activity.

    Directory of Open Access Journals (Sweden)

    Yoko Kato

    Full Text Available The assessment of the distribution and activity of vessel wall inflammation is clinically important in patients with Takayasu arteritis. Magnetic resonance imaging (MRI is a useful tool, but the clinical utility of late gadolinium enhancement (LGE in Takayasu arteritis has yet to be determined. The aim of the present study was to evaluate the utility of LGE in assessing vessel wall inflammation and disease activity in Takayasu arteritis.We enrolled 49 patients with Takayasu arteritis who had undergone 1.5 T MRI. Patients were divided into Active (n = 19 and Inactive disease (n = 30 groups. The distribution of vessel wall inflammation using angiography and LGE was assessed by qualitative analysis. In 79% and 63% of patients in Active and Inactive groups, respectively, greater distribution of vessel wall inflammation was observed with LGE than with conventional angiography. MRI values of pre- and post-contrast signal-to-noise ratios (SNR, SNR increment (post-SNR minus pre-SNR, pre- and post-contrast contrast-to-noise ratios (CNR, and CNR increment (post-CNR minus pre-CNR were evaluated at arterial wall sites with the highest signal intensity using quantitative analysis of post-contrast LGE images. No statistically significant differences in MRI parameters were observed between Active and Inactive groups. Contrast-enhanced MRI was unable to accurately detect active disease.Contrast-enhanced MRI has utility in detecting the distribution of vessel wall inflammation but has less utility in assessing disease activity in Takayasu arteritis.

  4. Three-dimensional imaging of the aortic vessel wall using an elastin-specific magnetic resonance contrast agent.

    Science.gov (United States)

    Makowski, Marcus R; Preissel, Anne; von Bary, Christian; Warley, Alice; Schachoff, Sylvia; Keithan, Alexandra; Cesati, Richard R; Onthank, David C; Schwaiger, Markus; Robinson, Simon P; Botnar, René M

    2012-07-01

    The aim of this study was to demonstrate the feasibility of high-resolution 3-dimensional aortic vessel wall imaging using a novel elastin-specific magnetic resonance contrast agent (ESMA) in a large animal model. The thoracic aortic vessel wall of 6 Landrace pigs was imaged using a novel ESMA and a nonspecific control agent. On day 1, imaging was performed before and after the administration of a nonspecific control agent, gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA; Bayer Schering AG, Berlin, Germany). On day 3, identical scans were repeated before and after the administration of a novel ESMA (Lantheus Medical Imaging, North Billerica, Massachusetts). Three-dimensional inversion recovery gradient echo delayed-enhancement imaging and magnetic resonance (MR) angiography of the thoracic aortic vessel wall were performed on a 1.5-T MR scanner (Achieva; Philips Medical Systems, the Netherlands). The signal-to-noise ratio and the contrast-to-noise ratio of arterial wall enhancement, including the time course of enhancement, were assessed for ESMA and Gd-DTPA. After the completion of imaging sessions, histology, electron microscopy, and inductively coupled plasma mass spectroscopy were performed to localize and quantify the gadolinium bound to the arterial vessel wall. Administration of ESMA resulted in a strong enhancement of the aortic vessel wall on delayed-enhancement imaging, whereas no significant enhancement could be measured with Gd-DTPA. Ninety to 100 minutes after the administration of ESMA, significantly higher signal-to-noise ratio and contrast-to-noise ratio could be measured compared with the administration of Gd-DTPA (45.7 ± 9.6 vs 13.2 ± 3.5, P wall imaging using a novel ESMA in a large animal model under conditions resembling a clinical setting. Such an approach could be useful for the fast 3-dimensional assessment of the arterial vessel wall in the context of atherosclerosis, aortic aneurysms, and hypertension.

  5. Saccharomyces cerevisiae gene expression changes during rotating wall vessel suspension culture

    Science.gov (United States)

    Johanson, Kelly; Allen, Patricia L.; Lewis, Fawn; Cubano, Luis A.; Hyman, Linda E.; Hammond, Timothy G.

    2002-01-01

    This study utilizes Saccharomyces cerevisiae to study genetic responses to suspension culture. The suspension culture system used in this study is the high-aspect-ratio vessel, one type of the rotating wall vessel, that provides a high rate of gas exchange necessary for rapidly dividing cells. Cells were grown in the high-aspect-ratio vessel, and DNA microarray and metabolic analyses were used to determine the resulting changes in yeast gene expression. A significant number of genes were found to be up- or downregulated by at least twofold as a result of rotational growth. By using Gibbs promoter alignment, clusters of genes were examined for promoter elements mediating these genetic changes. Candidate binding motifs similar to the Rap1p binding site and the stress-responsive element were identified in the promoter regions of differentially regulated genes. This study shows that, as in higher order organisms, S. cerevisiae changes gene expression in response to rotational culture and also provides clues for investigations into the signaling pathways involved in gravitational response.

  6. Investigation of residual stresses in thick-walled vessels with combination of autofrettage and wire-winding

    International Nuclear Information System (INIS)

    Sedighi, M.; Jabbari, A.H.

    2013-01-01

    Wire-winding and autofrettage processes can be used to introduce beneficial residual stress in the cylinder of thick-walled pressure vessels. In both techniques, internal residual compressive stress will increase internal pressure capacity, improve fatigue life and reduce fatigue crack initiation. The purpose of this paper is to analyze the effects of wire-winding on an autofrettaged thick-walled vessel. Direct method which is a modified Variable Material Properties (VMP) method has been used in order to calculate residual stresses in an autofrettaged vessel. Since wire-winding is done after autofrettage process, the tangent and/or Young's modulus could be changed. For this reason, a new wire-winding method based on Direct Method is introduced. The obtained results for wire-wound autofrettaged vessels are validated by finite element method. The results show that by using this approach, the residual hoop stresses in a wire-wound autofrettaged vessel have a more desirable distribution in the cylinder. -- Highlights: • Combination of autofrettage and wire-winding in pressure vessels has been presented. • A new method based on Direct method is presented for wire-winding process. • Residual hoop stresses are compared in vessels cylinders for different cases. • The residual hoop stress has a more desirable stress distribution. • The benefits of the combined vessel are highlighted in comparison with single cases

  7. CMR Catalog Service for the Web

    Science.gov (United States)

    Newman, Doug; Mitchell, Andrew

    2016-01-01

    With the impending retirement of Global Change Master Directory (GCMD) Application Programming Interfaces (APIs) the Common Metadata Repository (CMR) was charged with providing a collection-level Catalog Service for the Web (CSW) that provided the same level of functionality as GCMD. This talk describes the capabilities of the CMR CSW API with particular reference to the support of the Committee on Earth Observation Satellites (CEOS) Working Group on Information Systems and Services (WGISS) Integrated Catalog (CWIC).

  8. "Sausage-string" appearance of arteries and arterioles can be caused by an instability of the blood vessel wall

    DEFF Research Database (Denmark)

    Jacobsen, Jens Christian Brings; Beierholm, Ulrik; Mikkelsen, Rene

    2002-01-01

    Vascular damage induced by acute hypertension is preceded by a peculiar pattern where blood vessels show alternating regions of constrictions and dilations ("sausages on a string"). The pattern occurs in the smaller blood vessels, and it plays a central role in causing the vascular damage. A rela...... phenomenon. Experimental data suggest that the structural changes induced by the instability may cause secondary damage to the wall of small arteries and arterioles in the form of endothelial hyperpermeability followed by local fibrinoid necrosis of the vascular wall.......Vascular damage induced by acute hypertension is preceded by a peculiar pattern where blood vessels show alternating regions of constrictions and dilations ("sausages on a string"). The pattern occurs in the smaller blood vessels, and it plays a central role in causing the vascular damage....... A related vascular pattern has been observed in larger vessels from several organs during angiography. In the larger vessels the occurrence of the pattern does not appear to be related to acute hypertension. A unifying feature between the phenomenon in large and small vessels seems to be an increase...

  9. Rationalization and utilization of double-wall vacuum vessel for tokamak fusion facility

    International Nuclear Information System (INIS)

    Nakahira, Masataka

    2005-09-01

    Vacuum Vessel (VV) of ITER is difficult to apply a non-destructive in-service inspection (ISI) and then new safety concept is needed. Present fabrication standards are not applicable to the VV, because the access is limited to the backside of closure weld of double wall. Fabrication tolerance of VV is ± 5mm even the structure is huge as high as 10m. This accuracy requires a rational method on the estimation of welding deformation. In this report, an inherent safety feature of the tokamak is proved closing up a special characteristic of termination of fusion reaction due to tiny water leak. A rational concept not to require ISI without sacrificing safety is shown based on this result. A partial penetration T-welded joint is proposed to establish a rational fabrication method of double wall. Strength and susceptibility to crevice corrosion is evaluated for this joint and feasibility is confirmed. A rational method of estimation of welding deformation for large and complex structure is proposed and the efficiency is shown by comparing analysis and experimental results of full-scale test. (author)

  10. Distinct defects in collagen microarchitecture underlie vessel-wall failure in advanced abdominal aneurysms and aneurysms in Marfan syndrome

    NARCIS (Netherlands)

    Lindeman, J.H.N.; Ashcroft, B.A.; Beenakker, J.-W.M.; Es, M. van; Koekkoek, N.B.R.; Prins, F.A.; Tielemans, J.F.; Abdul-Hussien, H.; Bank, R.A.; Oosterkamp, T.H.

    2010-01-01

    An aneurysm of the aorta is a common pathology characterized by segmentalweakeningof the artery.Althoughit isgenerally accepted that the vessel-wall weakening is caused by an impaired collagen metabolism, a clear association has been demonstrated only for rare syndromes such as the vascular type

  11. Automated registration of multispectral MR vessel wall images of the carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Klooster, R. van ' t; Staring, M.; Reiber, J. H. C.; Lelieveldt, B. P. F.; Geest, R. J. van der, E-mail: rvdgeest@lumc.nl [Department of Radiology, Division of Image Processing, Leiden University Medical Center, 2300 RC Leiden (Netherlands); Klein, S. [Department of Radiology and Department of Medical Informatics, Biomedical Imaging Group Rotterdam, Erasmus MC, Rotterdam 3015 GE (Netherlands); Kwee, R. M.; Kooi, M. E. [Department of Radiology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht 6202 AZ (Netherlands)

    2013-12-15

    Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purpose of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and

  12. Automated registration of multispectral MR vessel wall images of the carotid artery

    International Nuclear Information System (INIS)

    Klooster, R. van 't; Staring, M.; Reiber, J. H. C.; Lelieveldt, B. P. F.; Geest, R. J. van der; Klein, S.; Kwee, R. M.; Kooi, M. E.

    2013-01-01

    Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purpose of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and

  13. Numerical modeling of the pulse wave propagation in large blood vessels based on liquid and wall interaction

    International Nuclear Information System (INIS)

    Rup, K; Dróżdż, A

    2014-01-01

    The purpose of this article is to develop a non-linear, one-dimensional model of pulse wave propagation in the arterial cardiovascular system. The model includes partial differential equations resulting from the balance of mass and momentum for the fluid-filled area and the balance equation for the area of the wall and vessels. The considered mathematical model of pulse wave propagation in the thoracic aorta section takes into account the viscous dissipation of fluid energy, realistic values of parameters describing the physicochemical properties of blood and vessel wall. Boundary and initial conditions contain the appropriate information obtained from in vivo measurements. As a result of the numerical solution of the mass and momentum balance equations for the blood and the equilibrium equation for the arterial wall area, time- dependent deformation, respective velocity profiles and blood pressure were determined.

  14. Effect of a new specimen size on fatigue crack growth behavior in thick-walled pressure vessels

    International Nuclear Information System (INIS)

    Shariati, Mahmoud; Mohammadi, Ehsan; Masoudi Nejad, Reza

    2017-01-01

    Fatigue crack growth in thick-walled pressure vessels is an important factor affecting their fracture. Predicting the path of fatigue crack growth in a pressure vessel is the main issue discussed in fracture mechanics. The objective of this paper is to design a new geometrical specimen in fatigue to define the behavior of semi-elliptical crack growth in thick-walled pressure vessels. In the present work, the importance of the behavior of fatigue crack in test specimen and real conditions in thick-walled pressure vessels is investigated. The results of fatigue loading on the new specimen are compared with the results of fatigue loading in a cylindrical pressure vessel and a standard specimen. Numerical and experimental methods are used to investigate the behavior of fatigue crack growth in the new specimen. For this purpose, a three-dimensional boundary element method is used for fatigue crack growth under stress field. The modified Paris model is used to estimate fatigue crack growth rates. In order to verify the numerical results, fatigue test is carried out on a couple of specimens with a new geometry made of ck45. A comparison between experimental and numerical results has shown good agreement. - Highlights: • This paper provides a new specimen to define the behavior of fatigue crack growth. • We estimate the behavior of fatigue crack growth in specimen and pressure vessel. • A 3D finite element model has been applied to estimate the fatigue life. • We compare the results of fatigue loading for cylindrical vessel and specimens. • Comparison between experimental and numerical results has shown a good agreement.

  15. The effect of a self-balancing through wall residual stress distribution on the extension of a through-wall crack in a pressure vessel

    International Nuclear Information System (INIS)

    Smith, E.

    1993-01-01

    Leak-before-break arguments for pressurized components involve a comparison of the critical size of crack that will grow unstably under accident loadings and the critical leakage crack size for normal operation loadings. The paper is concerned with the former crack size and particularly with regard to the effect of residual stresses on the critical unstable crack size. Results from an analysis of a simple simulation model are used to provide underpinning for the view, expressed by Green and Knowles at the 1992 American Society of Mechanical Engineers Pressure Vessel and Piping Conference, that self-balancing through-wall residual stresses have little overall effect on the extension of a through-wall crack in a pressure vessel

  16. Investigation into a major crack that occurred during fabrication of a thick walled alloy pressure vessel

    International Nuclear Information System (INIS)

    Griffiths, Roger R.

    2002-01-01

    A high pressure thick walled (171 mm+cladding) reactor was under construction when a crack, with a total length of about 2.5 m, occurred at a nozzle. An investigation was conducted to determine how manufacture could safely proceed. This revealed that the primary cause of cracking was the method by which preheat had been applied to the vessel for the welding operation, coupled with the very low impact values achieved by the weld metal in the as-welded condition. Investigation also centred on the use of dehydrogenation heat treatment (DHT) instead of an intermediate stress relief (ISR), and the oxidised nature of the fracture surface. The oxidation could not be satisfactorily explained, and as a result neither the time the fracture occurred nor the significance of applying DHT in place of ISR could be absolutely determined. Nevertheless it was concluded that fracture probably occurred before DHT was applied. It was recommended that the method of preheat be revised and ISR applied without cooling below minimum preheat temperature. Further review of the incident resulted in additional recommendations for prevention of a recurrence in future work. One critical aspect was the lack of response to the poor as-welded toughness properties of the weld deposit

  17. Investigation into a major crack that occurred during fabrication of a thick walled alloy pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, Roger R

    2002-08-01

    A high pressure thick walled (171 mm+cladding) reactor was under construction when a crack, with a total length of about 2.5 m, occurred at a nozzle. An investigation was conducted to determine how manufacture could safely proceed. This revealed that the primary cause of cracking was the method by which preheat had been applied to the vessel for the welding operation, coupled with the very low impact values achieved by the weld metal in the as-welded condition. Investigation also centred on the use of dehydrogenation heat treatment (DHT) instead of an intermediate stress relief (ISR), and the oxidised nature of the fracture surface. The oxidation could not be satisfactorily explained, and as a result neither the time the fracture occurred nor the significance of applying DHT in place of ISR could be absolutely determined. Nevertheless it was concluded that fracture probably occurred before DHT was applied. It was recommended that the method of preheat be revised and ISR applied without cooling below minimum preheat temperature. Further review of the incident resulted in additional recommendations for prevention of a recurrence in future work. One critical aspect was the lack of response to the poor as-welded toughness properties of the weld deposit.

  18. Fracture mechanics of thin wall cylindrical pressure vessels: an interim review

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Olson, N.J.

    1977-08-01

    The report is a result of activities in the LMFBR Fuel Rod Transient Performance Program sponsored by the LMFBR Branch of the Division of Project Management, U.S. Nuclear Regulatory Commission. One of the objectives is to develop predictions relative to the length, direction, and rate of growth of cladding rips subsequent to (or concurrent with) the initial cladding breach during unprotected transients. To provide a basis for evaluation, Battelle, Pacific Northwest Laboratories has reviewed most available fracture mechanics assessments relative to thin-wall cylindrical pressure vessels. The purpose of the report is to review the various fracture mechanics models and to describe the pertinent fracture parameters. It is intended to provide a formal basis for assessing future analytical predictions of fracture behavior of materials exposed to transient LMFBR thermal and mechanical loading conditions. In addition, the report is expected to provide reference material for evaluating or developing experimental programs required to properly address the problem of predicting fracture behavior of materials during transient events

  19. Critical Heat Flux Experiments on the Reactor Vessel Wall Using 2-D Slice Test Section

    International Nuclear Information System (INIS)

    Jeong, Yong Hoon; Chang, Soon Heung; Baek, Won-Pil

    2005-01-01

    The critical heat flux (CHF) on the reactor vessel outer wall was measured using the two-dimensional slice test section. The radius and the channel area of the test section were 2.5 m and 10 cm x 15 cm, respectively. The flow channel area and the heater width were smaller than those of the ULPU experiments, but the radius was greater than that of the ULPU. The CHF data under the inlet subcooling of 2 to 25 deg. C and the mass flux 0 to 300 kg/m 2 .s had been acquired. The measured CHF value was generally slightly lower than that of the ULPU. The difference possibly comes from the difference of the test section material and the thickness. However, the general trend of CHF according to the mass flux was similar with that of the ULPU. The experimental CHF data were compared with the predicted values by SULTAN correlation. The SULTAN correlation predicted well this study's data only for the mass flux higher than 200 kg/m 2 .s, and for the exit quality lower than 0.05. The local condition-based correlation was developed, and it showed good prediction capability for broad quality (-0.01 to 0.5) and mass flux ( 2 .s) conditions with a root-mean-square error of 2.4%. There were increases in the CHF with trisodium phosphate-added water

  20. Manufacturing and maintenance technologies developed for a thick-wall structure of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Onozuka, M.; Alfile, J.P.; Aubert, Ph.; Dagenais, J.-F.; Grebennikov, D.; Ioki, K.; Jones, L.; Koizumi, K.; Krylov, V.; Maslakowski, J.; Nakahira, M.; Nelson, B.; Punshon, C.; Roy, O.; Schreck, G.

    2001-01-01

    Development of welding, cutting and non-destructive testing (NDT) techniques, and development of remotized systems have been carried out for on-site manufacturing and maintenance of the thick-wall structure of the International Thermonuclear Experimental Reactor (ITER) vacuum vessel (VV). Conventional techniques, including tungsten inert gas welding, plasma cutting, and ultrasonic inspection, have been improved and optimized for the application to thick austenitic stainless steel plates. In addition, advanced methods have been investigated, including reduced-pressure electron-beam and multi-pass neodymium-doped yttrium aluminum garnet (NdYAG) laser welding, NdYAG laser cutting, and electro-magnetic acoustic transducer inspection, to improve cost and technical performance. Two types of remotized systems with different payloads have been investigated and one of them has been fabricated and demonstrated in field joint welding, cutting, and NDT tests on test mockups and full-scale ITER VV sector models. The progress and results of this development to date provide a high level of confidence that the manufacturing and maintenance of the ITER VV is feasible

  1. Manufacturing and maintenance technologies developed for a thick-wall structure of the ITER vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M. E-mail: onozukm@itereu.de; Alfile, J.P.; Aubert, Ph.; Dagenais, J.-F.; Grebennikov, D.; Ioki, K.; Jones, L.; Koizumi, K.; Krylov, V.; Maslakowski, J.; Nakahira, M.; Nelson, B.; Punshon, C.; Roy, O.; Schreck, G

    2001-09-01

    Development of welding, cutting and non-destructive testing (NDT) techniques, and development of remotized systems have been carried out for on-site manufacturing and maintenance of the thick-wall structure of the International Thermonuclear Experimental Reactor (ITER) vacuum vessel (VV). Conventional techniques, including tungsten inert gas welding, plasma cutting, and ultrasonic inspection, have been improved and optimized for the application to thick austenitic stainless steel plates. In addition, advanced methods have been investigated, including reduced-pressure electron-beam and multi-pass neodymium-doped yttrium aluminum garnet (NdYAG) laser welding, NdYAG laser cutting, and electro-magnetic acoustic transducer inspection, to improve cost and technical performance. Two types of remotized systems with different payloads have been investigated and one of them has been fabricated and demonstrated in field joint welding, cutting, and NDT tests on test mockups and full-scale ITER VV sector models. The progress and results of this development to date provide a high level of confidence that the manufacturing and maintenance of the ITER VV is feasible.

  2. Preliminary electromagnetic, thermal and mechanical design for first wall and vacuum vessel of FAST

    Energy Technology Data Exchange (ETDEWEB)

    Lucca, F., E-mail: Flavio.Lucca@LTCalcoli.it [LT Calcoli srl, Piazza Prinetti 26/B, 23807 Merate, LC (Italy); Bertolini, C. [LT Calcoli srl, Piazza Prinetti 26/B, 23807 Merate, LC (Italy); Crescenzi, F.; Crisanti, F. [C.R. ENEA Frascati – UT FUS, Via E. Fermi 45, IT-00044 Frascati, RM (Italy); Di Gironimo, G. [CREATE, Università di Napoli Federico II, P.le Tecchio 80, 80125 Napoli (Italy); Labate, C. [CREATE, Università di Napoli Parthenope, Via Acton 38, 80133 Napoli (Italy); Manzoni, M.; Marconi, M.; Pagani, I. [LT Calcoli srl, Piazza Prinetti 26/B, 23807 Merate, LC (Italy); Ramogida, G. [C.R. ENEA Frascati – UT FUS, Via E. Fermi 45, IT-00044 Frascati, RM (Italy); Renno, F. [CREATE, Università di Napoli Federico II, P.le Tecchio 80, 80125 Napoli (Italy); Roccella, M. [LT Calcoli srl, Piazza Prinetti 26/B, 23807 Merate, LC (Italy); Roccella, S. [C.R. ENEA Frascati – UT FUS, Via E. Fermi 45, IT-00044 Frascati, RM (Italy); Viganò, F. [LT Calcoli srl, Piazza Prinetti 26/B, 23807 Merate, LC (Italy)

    2015-10-15

    The fusion advanced study torus (FAST), with its compact design, high toroidal field and plasma current, faces many of the problems met by ITER, and at the same time anticipates much of the DEMO relevant physics and technology. The conceptual design of the first wall (FW) and the vacuum vessel (VV) has been defined on the basis of FAST operative conditions and of “Snow Flakes” (SF) magnetic topology, which is also relevant for DEMO. The EM loads are one of the most critical load components for the FW and the VV during plasma disruptions and a first dimensioning of these components for such loads is mandatory. During this first phase of R&D activities the conceptual design of the FW and VV have been assessed estimating, by means of FE simulations, the EM loads due to a typical vertical disruption event (VDE) in FAST. EM loads were then transferred on a FE mechanical model of the FAST structures and the mechanical response of the FW and VV design for the analyzed VDE event was assessed. The results indicate that design criteria are not fully satisfied by the current drawing of the VV and FW components. The most critical regions have been individuated and the effect of some geometrical and material changes has been checked in order to improve the structure.

  3. Cell culture for three-dimensional modeling in rotating-wall vessels: an application of simulated microgravity

    Science.gov (United States)

    Schwarz, R. P.; Goodwin, T. J.; Wolf, D. A.

    1992-01-01

    High-density, three-dimensional cell cultures are difficult to grow in vitro. The rotating-wall vessel (RWV) described here has cultured BHK-21 cells to a density of 1.1 X 10(7) cells/ml. Cells on microcarriers were observed to grow with enhanced bridging in this batch culture system. The RWV is a horizontally rotated tissue culture vessel with silicon membrane oxygenation. This design results in a low-turbulence, low-shear cell culture environment with abundant oxygenation. The RWV has the potential to culture a wide variety of normal and neoplastic cells.

  4. Semiautomatic vessel wall detection and quantification of wall thickness in computed tomography images of human abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Shum, Judy; DiMartino, Elena S.; Goldhammer, Adam; Goldman, Daniel H.; Acker, Leah C.; Patel, Gopal; Ng, Julie H.; Martufi, Giampaolo; Finol, Ender A.

    2010-01-01

    Purpose: Quantitative measurements of wall thickness in human abdominal aortic aneurysms (AAAs) may lead to more accurate methods for the evaluation of their biomechanical environment. Methods: The authors describe an algorithm for estimating wall thickness in AAAs based on intensity histograms and neural networks involving segmentation of contrast enhanced abdominal computed tomography images. The algorithm was applied to ten ruptured and ten unruptured AAA image data sets. Two vascular surgeons manually segmented the lumen, inner wall, and outer wall of each data set and a reference standard was defined as the average of their segmentations. Reproducibility was determined by comparing the reference standard to lumen contours generated automatically by the algorithm and a commercially available software package. Repeatability was assessed by comparing the lumen, outer wall, and inner wall contours, as well as wall thickness, made by the two surgeons using the algorithm. Results: There was high correspondence between automatic and manual measurements for the lumen area (r=0.978 and r=0.996 for ruptured and unruptured aneurysms, respectively) and between vascular surgeons (r=0.987 and r=0.992 for ruptured and unruptured aneurysms, respectively). The authors' automatic algorithm showed better results when compared to the reference with an average lumen error of 3.69%, which is less than half the error between the commercially available application Simpleware and the reference (7.53%). Wall thickness measurements also showed good agreement between vascular surgeons with average coefficients of variation of 10.59% (ruptured aneurysms) and 13.02% (unruptured aneurysms). Ruptured aneurysms exhibit significantly thicker walls (1.78±0.39 mm) than unruptured ones (1.48±0.22 mm), p=0.044. Conclusions: While further refinement is needed to fully automate the outer wall segmentation algorithm, these preliminary results demonstrate the method's adequate reproducibility and

  5. Nonparenchymal cells cultivated from explants of fibrotic liver resemble endothelial and smooth muscle cells from blood vessel walls

    International Nuclear Information System (INIS)

    Voss, B.; Rauterberg, J.; Pott, G.; Brehmer, U.; Allam, S.; Lehmann, R.; von Bassewitz, D.B.

    1982-01-01

    Tissue specimens from human fibrotic liver obtained by needle biopsy were cultured. Two cell types emerged from the tissue explants. From their morphology and biosynthetic products they resembled smooth muscle cells and endothelial cells from blood vessel walls. In the endothelial cells, factor VIII-associated protein was demonstrated by indirect immunofluorescence. Synthesis of collagen types I and III, basement membrane collagen types IV and V, and fibronectin by both cell types was observed by immunofluorescence microscopy. Homogeneous cultures of smooth muscle cells were observed in subcultures. After incubation with [ 14 C]glycine, collagen was isolated and characterized by CM cellulose chromatography, and consisted mainly of types I and III. These data suggest involvement of mesenchymal cells in hepatic fibrosis; they presumably originate from blood vessel or sinusoidal walls

  6. Lymphocyte trafficking and HIV infection of human lymphoid tissue in a rotating wall vessel bioreactor

    Science.gov (United States)

    Margolis, L. B.; Fitzgerald, W.; Glushakova, S.; Hatfill, S.; Amichay, N.; Baibakov, B.; Zimmerberg, J.

    1997-01-01

    The pathogenesis of HIV infection involves a complex interplay between both the infected and noninfected cells of human lymphoid tissue, the release of free viral particles, the de novo infection of cells, and the recirculatory trafficking of peripheral blood lymphocytes. To develop an in vitro model for studying these various aspects of HIV pathogenesis we have utilized blocks of surgically excised human tonsils and a rotating wall vessel (RWV) cell culture system. Here we show that (1) fragments of the surgically excised human lymphoid tissue remain viable and retain their gross cytoarchitecture for at least 3 weeks when cultured in the RWV system; (2) such lymphoid tissue gradually shows a loss of both T and B cells to the surrounding growth medium; however, this cellular migration is reversible as demonstrated by repopulation of the tissue by labeled cells from the growth medium; (3) this cellular migration may be partially or completely inhibited by embedding the blocks of lymphoid tissue in either a collagen or agarose gel matrix; these embedded tissue blocks retain most of the basic elements of a normal lymphoid cytoarchitecture; and (4) both embedded and nonembedded RWV-cultured blocks of human lymphoid tissue are capable of productive infection by HIV-1 of at least three various strains of different tropism and phenotype, as shown by an increase in both p24 antigen levels and free virus in the culture medium, and by the demonstration of HIV-1 RNA-positive cells inside the tissue identified by in situ hybridization. It is therefore reasonable to suggest that gel-embedded and nonembedded blocks of human lymphoid tissue, cocultured with a suspension of tonsillar lymphocytes in an RWV culture system, constitute a useful model for simulating normal lymphocyte recirculatory traffic and provide a new tool for testing the various aspects of HIV pathogenesis.

  7. Vascular smooth muscle cells in cultures on lactide based polymers for potential construction of artificial vessel wall

    Czech Academy of Sciences Publication Activity Database

    Filová, Elena; Bačáková, Lucie; Lisá, Věra; Machová, Luďka; Lapčíková, Monika; Kubies, Dana; Proks, Vladimír; Rypáček, František

    2003-01-01

    Roč. 6, - (2003), s. 9-11 ISSN 1429-7248. [Konferencja Naukowa "Biomaterialy w medycynie i weterynarii" /13./. Rytro, 09.10.2003-12.10.2003] R&D Projects: GA AV ČR IAA4050202; GA MŠk LN00A065 Institutional research plan: CEZ:AV0Z4050913; CEZ:AV0Z5011922 Keywords : tissue engineering * bioactive polymers, RGD * bioartificial vessel wall Subject RIV: EI - Biotechnology ; Bionics

  8. Bobbin-Tool Friction-Stir Welding of Thick-Walled Aluminum Alloy Pressure Vessels

    Energy Technology Data Exchange (ETDEWEB)

    Dalder, E C; Pastrnak, J W; Engel, J; Forrest, R S; Kokko, E; Ternan, K M; Waldron, D

    2007-06-06

    It was desired to assemble thick-walled Al alloy 2219 pressure vessels by bobbin-tool friction-stir welding. To develop the welding-process, mechanical-property, and fitness-for-service information to support this effort, extensive friction-stir welding-parameter studies were conducted on 2.5 cm. and 3.8 cm. thick 2219 Al alloy plate. Starting conditions of the plate were the fully-heat-treated (-T62) and in the annealed (-O) conditions. The former condition was chosen with the intent of using the welds in either the 'as welded' condition or after a simple low-temperature aging treatment. Since preliminary stress-analyses showed that stresses in and near the welds would probably exceed the yield-strength of both 'as welded' and welded and aged weld-joints, a post-weld solution-treatment, quenching, and aging treatment was also examined. Once a suitable set of welding and post-weld heat-treatment parameters was established, the project divided into two parts. The first part concentrated on developing the necessary process information to be able to make defect-free friction-stir welds in 3.8 cm. thick Al alloy 2219 in the form of circumferential welds that would join two hemispherical forgings with a 102 cm. inside diameter. This necessitated going to a bobbin-tool welding-technique to simplify the tooling needed to react the large forces generated in friction-stir welding. The bobbin-tool technique was demonstrated on both flat-plates and plates that were bent to the curvature of the actual vessel. An additional issue was termination of the weld, i.e. closing out the hole left at the end of the weld by withdrawal of the friction-stir welding tool. This was accomplished by friction-plug welding a slightly-oversized Al alloy 2219 plug into the termination-hole, followed by machining the plug flush with both the inside and outside surfaces of the vessel. The second part of the project involved demonstrating that the welds were fit for the intended

  9. Method for the radiographic examination of the walls or components of an essentially closed vessel, and also the provision of means for the application of the method

    International Nuclear Information System (INIS)

    1978-01-01

    Method for the radiographic examination of the wall ports or supporting components of an essentially closed vessel, whereby one brings to the side of the vessel walls or supports under examination a radiation source and, to the opposite side, a radiation sensitive film, the film being irradiated by the source and thereafter developed, characterised in that one introduces into the inside of the vessel a hollow tube at a unique distance from the wall or support component, at least one end of the hollow tube being fed out and in which the hollow tube, during the period of the examination, the irradiation source or an irradiation sensitive film is introduced. (G.C.)

  10. Learning-based automated segmentation of the carotid artery vessel wall in dual-sequence MRI using subdivision surface fitting.

    Science.gov (United States)

    Gao, Shan; van 't Klooster, Ronald; Kitslaar, Pieter H; Coolen, Bram F; van den Berg, Alexandra M; Smits, Loek P; Shahzad, Rahil; Shamonin, Denis P; de Koning, Patrick J H; Nederveen, Aart J; van der Geest, Rob J

    2017-10-01

    The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. The proposed method segments the lumen and outer wall surfaces including the bifurcation region by fitting a subdivision surface constructed hierarchical-tree model to the image data. In particular, a hybrid segmentation which combines deformable model fitting with boundary classification was applied to extract the lumen surface. The 3D model ensures the correct shape and topology of the carotid artery, while the boundary classification uses combined image information of 3D TOF-MRA and 3D BB-MRI to promote accurate delineation of the lumen boundaries. The proposed algorithm was validated on 25 subjects (48 arteries) including both healthy volunteers and atherosclerotic patients with 30% to 70% carotid stenosis. For both lumen and outer wall border detection, our result shows good agreement between manually and automatically determined contours, with contour-to-contour distance less than 1 pixel as well as Dice overlap greater than 0.87 at all different carotid artery sections. The presented 3D segmentation technique has demonstrated the capability of providing vessel wall delineation for 3D carotid MRI data with high accuracy and limited user interaction. This brings benefits to large-scale patient studies for assessing the effect of pharmacological treatment of atherosclerosis by reducing image analysis time and bias between human observers. © 2017 American Association of Physicists in Medicine.

  11. Energy release and its containment within thin-walled, backed vessels

    International Nuclear Information System (INIS)

    Chambers, D.I.

    1983-01-01

    The problem adressed is the containment of a sudden release of energy of a magnitude up to 4 x 10 11 joules in a reusable vessel. The design process began by formulating dynamic models for both the input to such a vessel and the vessel itself and using these models to generate a general response. Modifications to the input and a more specific response are discussed. Computer codes used in calculations are described and listed

  12. Evaluation of Pulmonary Hypertension with CMR: Pulmonary Hypertension 
Patients and Healthy Volunteers Control Study

    Directory of Open Access Journals (Sweden)

    Meng WANG

    2016-05-01

    Full Text Available Background and objective The clinical course of pulmonary hypertension (PH is one of progressive deterioration interspersed with episodes of acute decompensation. It is difficult to predict when patients will die because death may come either suddenly or slowly due to progressive heart failure. The aim of this study is to investigate morphology, function and hemodynamics in PH, compared with healthy people, and to investigate the clinical value of detection of PH by use of cardiac magnetic resonance (CMR parameters. Methods CMR was performed in 56 PH patients collected from Tianjin Medical University General Hospital from January 2012 to December 2014 and 22 healthy controls. The following parameters were calculated: right ventricle (RV end-diastolic volume (EDV, end-systolic volume (ESV, ejection fraction (EF, myocardial mass (MM, RV fractional area change (RVFAC, interventricular septal curvature (CIVS, left ventricular free wall curvature (CFW, and CIVS/CFW, main pulmonary artery (MPA positive peak velocity, maximal area, minimal area and distensibility. Comparisons of CMR measurements between PH patients and controls were analyzed by using the student t-tests. Receiver operating characteristic (ROC curve analysis was used to compare the PH diagnostic abilities for four parameters (MPA positive peak velocity, distensibility, curvature ratio, and RVFAC and combined CMR parameter. P<0.05 was considered significant. Results Compared with healthy controls, RV morphology, function and hemodynamics of PH group declined and deteriorate obviously. The ROC curve analysis showed that among the four parameters distensibility of MPA had the highest AUC value (AUC=0.95. Additionally, combined CMR parameter (positive peak velocity+distensibility+curvature ratio+RVFAC had even higher AUC (AUC=0.988. Conclusion Comprehensive CMR parameters is conducive to accurately reflect the overall state RV-pulmonary circulation in patients with PH.

  13. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    Science.gov (United States)

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

  14. HIV-1 and recombinant gp120 affect the survival and differentiation of human vessel wall-derived mesenchymal stem cells

    Directory of Open Access Journals (Sweden)

    Pasquinelli Gianandrea

    2011-05-01

    Full Text Available Abstract Background HIV infection elicits the onset of a progressive immunodeficiency and also damages several other organs and tissues such as the CNS, kidney, heart, blood vessels, adipose tissue and bone. In particular, HIV infection has been related to an increased incidence of cardiovascular diseases and derangement in the structure of blood vessels in the absence of classical risk factors. The recent characterization of multipotent mesenchymal cells in the vascular wall, involved in regulating cellular homeostasis, suggests that these cells may be considered a target of HIV pathogenesis. This paper investigated the interaction between HIV-1 and vascular wall resident human mesenchymal stem cells (MSCs. Results MSCs were challenged with classical R5 and X4 HIV-1 laboratory strains demonstrating that these strains are able to enter and integrate their retro-transcribed proviral DNA in the host cell genome. Subsequent experiments indicated that HIV-1 strains and recombinant gp120 elicited a reliable increase in apoptosis in sub-confluent MSCs. Since vascular wall MSCs are multipotent cells that may be differentiated towards several cell lineages, we challenged HIV-1 strains and gp120 on MSCs differentiated to adipogenesis and endotheliogenesis. Our experiments showed that the adipogenesis is increased especially by upregulated PPARγ activity whereas the endothelial differentiation induced by VEGF treatment was impaired with a downregulation of endothelial markers such as vWF, Flt-1 and KDR expression. These viral effects in MSC survival and adipogenic or endothelial differentiation were tackled by CD4 blockade suggesting an important role of CD4/gp120 interaction in this context. Conclusions The HIV-related derangement of MSC survival and differentiation may suggest a direct role of HIV infection and gp120 in impaired vessel homeostasis and in genesis of vessel damage observed in HIV-infected patients.

  15. High-resolution MRI vessel wall imaging: spatial and temporal patterns of reversible cerebral vasoconstriction syndrome and central nervous system vasculitis.

    Science.gov (United States)

    Obusez, E C; Hui, F; Hajj-Ali, R A; Cerejo, R; Calabrese, L H; Hammad, T; Jones, S E

    2014-08-01

    High-resolution MR imaging is an emerging tool for evaluating intracranial artery disease. It has an advantage of defining vessel wall characteristics of intracranial vascular diseases. We investigated high-resolution MR imaging arterial wall characteristics of CNS vasculitis and reversible cerebral vasoconstriction syndrome to determine wall pattern changes during a follow-up period. We retrospectively reviewed 3T-high-resolution MR imaging vessel wall studies performed on 26 patients with a confirmed diagnosis of CNS vasculitis and reversible cerebral vasoconstriction syndrome during a follow-up period. Vessel wall imaging protocol included black-blood contrast-enhanced T1-weighted sequences with fat suppression and a saturation band, and time-of-flight MRA of the circle of Willis. Vessel wall characteristics including enhancement, wall thickening, and lumen narrowing were collected. Thirteen patients with CNS vasculitis and 13 patients with reversible cerebral vasoconstriction syndrome were included. In the CNS vasculitis group, 9 patients showed smooth, concentric wall enhancement and thickening; 3 patients had smooth, eccentric wall enhancement and thickening; and 1 patient was without wall enhancement and thickening. Six of 13 patients had follow-up imaging; 4 patients showed stable smooth, concentric enhancement and thickening; and 2 patients had resoluton of initial imaging findings. In the reversible cerebral vasoconstriction syndrome group, 10 patients showed diffuse, uniform wall thickening with negligible-to-mild enhancement. Nine patients had follow-up imaging, with 8 patients showing complete resolution of the initial findings. Postgadolinium 3T-high-resolution MR imaging appears to be a feasible tool in differentiating vessel wall patterns of CNS vasculitis and reversible cerebral vasoconstriction syndrome changes during a follow-up period. © 2014 by American Journal of Neuroradiology.

  16. Nonlinear response of vessel walls due to short-time thermomechanical loading

    International Nuclear Information System (INIS)

    Pfeiffer, P.A.; Kulak, R.F.

    1994-01-01

    Maintaining structural integrity of the reactor pressure vessel (RPV) during a postulated core melt accident is an important safety consideration in the design of the vessel. This study addresses the failure predictions of the vessel due to thermal and pressure loadings fro the molten core debris depositing on the lower head of the vessel. Different loading combinations were considered based on the dead load, yield stress assumptions, material response and internal pressurization. The analyses considered only short term failure (quasi static) modes, long term failure modes were not considered. Short term failure modes include plastic instabilities of the structure and failure due to exceeding the failure strain. Long term failure odes would be caused by creep rupture that leads to plastic instability of the structure. Due to the sort time durations analyzed, creep was not considered in the analyses presented

  17. Association between proximal internal carotid artery steno-occlusive disease and diffuse wall thickening in its petrous segment: a magnetic resonance vessel wall imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiaoyi; Li, Dongye [Capital Medical University and Beijing Institute for Brain Disorders, Center for Brain Disorders Research, Beijing (China); Tsinghua University School of Medicine, Center for Biomedical Imaging Research, Department of Biomedical Engineering, Beijing (China); Zhao, Huilin [Shanghai Jiao Tong University, Department of Radiology, Renji Hospital, School of Medicine, Shanghai (China); Chen, Zhensen; Qiao, Huiyu; He, Le; Li, Rui [Tsinghua University School of Medicine, Center for Biomedical Imaging Research, Department of Biomedical Engineering, Beijing (China); Cui, Yuanyuan [PLA General Hospital, Department of Radiology, Beijing (China); Zhou, Zechen [Philips Research China, Healthcare Department, Beijing (China); Yuan, Chun [Tsinghua University School of Medicine, Center for Biomedical Imaging Research, Department of Biomedical Engineering, Beijing (China); University of Washington, Department of Radiology, Seattle, WA (United States); Zhao, Xihai [Tsinghua University School of Medicine, Center for Biomedical Imaging Research, Department of Biomedical Engineering, Beijing (China); Beijing Institute for Brain Disorders, Center for Stroke, Beijing (China)

    2017-05-15

    Significant stenosis or occlusion in carotid arteries may lead to diffuse wall thickening (DWT) in the arterial wall of downstream. This study aimed to investigate the correlation between proximal internal carotid artery (ICA) steno-occlusive disease and DWT in ipsilateral petrous ICA. Symptomatic patients with atherosclerotic stenosis (>0%) in proximal ICA were recruited and underwent carotid MR vessel wall imaging. The 3D motion sensitized-driven equilibrium prepared rapid gradient-echo (3D-MERGE) was acquired for characterizing the wall thickness and longitudinal extent of the lesions in petrous ICA and the distance from proximal lesion to the petrous ICA. The stenosis degree in proximal ICA was measured on the time-of-flight (TOF) images. In total, 166 carotid arteries from 125 patients (mean age 61.0 ± 10.5 years, 99 males) were eligible for final analysis and 64 showed DWT in petrous ICAs. The prevalence of severe DWT in petrous ICA was 1.4%, 5.3%, 5.9%, and 80.4% in ipsilateral proximal ICAs with stenosis category of 1%-49%, 50%-69%, 70%-99%, and total occlusion, respectively. Proximal ICA stenosis was significantly correlated with the wall thickness in petrous ICA (r = 0.767, P < 0.001). Logistic regression analysis showed that proximal ICA stenosis was independently associated with DWT in ipsilateral petrous ICA (odds ratio (OR) = 2.459, 95% confidence interval (CI) 1.896-3.189, P < 0.001). Proximal ICA steno-occlusive disease is independently associated with DWT in ipsilateral petrous ICA. (orig.)

  18. Association between proximal internal carotid artery steno-occlusive disease and diffuse wall thickening in its petrous segment: a magnetic resonance vessel wall imaging study

    International Nuclear Information System (INIS)

    Chen, Xiaoyi; Li, Dongye; Zhao, Huilin; Chen, Zhensen; Qiao, Huiyu; He, Le; Li, Rui; Cui, Yuanyuan; Zhou, Zechen; Yuan, Chun; Zhao, Xihai

    2017-01-01

    Significant stenosis or occlusion in carotid arteries may lead to diffuse wall thickening (DWT) in the arterial wall of downstream. This study aimed to investigate the correlation between proximal internal carotid artery (ICA) steno-occlusive disease and DWT in ipsilateral petrous ICA. Symptomatic patients with atherosclerotic stenosis (>0%) in proximal ICA were recruited and underwent carotid MR vessel wall imaging. The 3D motion sensitized-driven equilibrium prepared rapid gradient-echo (3D-MERGE) was acquired for characterizing the wall thickness and longitudinal extent of the lesions in petrous ICA and the distance from proximal lesion to the petrous ICA. The stenosis degree in proximal ICA was measured on the time-of-flight (TOF) images. In total, 166 carotid arteries from 125 patients (mean age 61.0 ± 10.5 years, 99 males) were eligible for final analysis and 64 showed DWT in petrous ICAs. The prevalence of severe DWT in petrous ICA was 1.4%, 5.3%, 5.9%, and 80.4% in ipsilateral proximal ICAs with stenosis category of 1%-49%, 50%-69%, 70%-99%, and total occlusion, respectively. Proximal ICA stenosis was significantly correlated with the wall thickness in petrous ICA (r = 0.767, P < 0.001). Logistic regression analysis showed that proximal ICA stenosis was independently associated with DWT in ipsilateral petrous ICA (odds ratio (OR) = 2.459, 95% confidence interval (CI) 1.896-3.189, P < 0.001). Proximal ICA steno-occlusive disease is independently associated with DWT in ipsilateral petrous ICA. (orig.)

  19. Development of a sensitive experimental set-up for LIF fuel wall film measurements in a pressure vessel

    Science.gov (United States)

    Schulz, Florian; Schmidt, Jürgen; Beyrau, Frank

    2015-05-01

    This paper focusses on fundamental investigations of fuel wall films, which are formed when the spray impinges on the piston or cylinder walls. To reproduce the wide range of operating conditions within homogeneously charged gasoline direct-injection engines, it is necessary to use a film thickness measurement method, which can be applied inside a high-pressure, high-temperature vessel. Hence, we developed a method based on laser-induced fluorescence that reaches: a precision better than 1 µm, a geometric resolution of 31 µm and a practical applicability for wall film thicknesses smaller 80 µm. To obtain accurate film thickness results, we provide a detailed description of the selection of the surrogate fuel isooctane with 3-pentanone as fluorescence tracer and the resulting assembly of the excitation source, beam expander, filters, camera and the essential image processing. Furthermore, advantages and disadvantages of other possible solutions are discussed. Earlier publications provide only little information about the accuracy of their calibration and measurement procedures. Therefore, we tested and compared three basic calibration methods to each other and provide an analysis of possible errors, such as the influence of the preferential evaporation of 3-pentanone. Finally, images of resulting wall films are presented, and practical considerations for the execution of the measurements like recording timings are discussed.

  20. Evaluation of thermal ratcheting of reactor vessel wall near the sodium surface

    International Nuclear Information System (INIS)

    Take, Kohji; Fujioka, Terutaka; Yano, Kazutaka

    1989-01-01

    Plastic ratcheting of reactor vessels may occur by an axially moving thermal gradient without primary stress. So there is a need to establish a proper prediction method for the plastic ratcheting. In this study, inelastic FEM analyses of reactor vessel model by using an advanced constitutive equation were carried out in order to comprehend plastic ratcheting behaviour of cylinder which subject to an axially moving thermal gradient. As a result of analyses, a basic mechanism of this ratcheting was found. And it also indicated that cyclic hardening behaviour will became important for development of evaluation method. (author)

  1. Design and material selection for ITER first wall/blanket, divertor and vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, K.; Barabash, V.; Cardella, A.; Elio, F.; Gohar, Y.; Janeschitz, G.; Johnson, G.; Kalinin, G.; Lousteau, D.; Onozuka, M.; Parker, R.; Sannazzaro, G.; Tivey, R. [ITER JCT, Garching (Germany)

    1998-10-01

    Design and R and D have progressed on the ITER vacuum vessel, shielding and breeding blankets, and the divertor. The principal materials have been selected and the fabrication methods selected for most of the components based on design and R and D results. The resulting design changes are discussed for each system. (orig.) 11 refs.

  2. Design and material selection for ITER first wall/blanket, divertor and vacuum vessel

    Science.gov (United States)

    Ioki, K.; Barabash, V.; Cardella, A.; Elio, F.; Gohar, Y.; Janeschitz, G.; Johnson, G.; Kalinin, G.; Lousteau, D.; Onozuka, M.; Parker, R.; Sannazzaro, G.; Tivey, R.

    1998-10-01

    Design and R&D have progressed on the ITER vacuum vessel, shielding and breeding blankets, and the divertor. The principal materials have been selected and the fabrication methods selected for most of the components based on design and R&D results. The resulting design changes are discussed for each system.

  3. Essential Structural and Functional Roles of the Cmr4 Subunit in RNA Cleavage by the Cmr CRISPR-Cas Complex

    Directory of Open Access Journals (Sweden)

    Nancy F. Ramia

    2014-12-01

    Full Text Available Summary: The Cmr complex is the multisubunit effector complex of the type III-B clustered regularly interspaced short palindromic repeats (CRISPR-Cas immune system. The Cmr complex recognizes a target RNA through base pairing with the integral CRISPR RNA (crRNA and cleaves the target at multiple regularly spaced locations within the complementary region. To understand the molecular basis of the function of this complex, we have assembled information from electron microscopic and X-ray crystallographic structural studies and mutagenesis of a complete Pyrococcus furiosus Cmr complex. Our findings reveal that four helically packed Cmr4 subunits, which make up the backbone of the Cmr complex, act as a platform to support crRNA binding and target RNA cleavage. Interestingly, we found a hook-like structural feature associated with Cmr4 that is likely the site of target RNA binding and cleavage. Our results also elucidate analogies in the mechanisms of crRNA and target molecule binding by the distinct Cmr type III-A and Cascade type I-E complexes. : Ramia et al. show that the helical core of the type III-B Cmr CRISPR-Cas effector complex, made up of multiple Cmr4 subunits, forms the platform for a corresponding number of cleavages of the target RNA. Comparison with the type I-E Cascade structure reveals strikingly similar mechanisms of crRNA and target binding.

  4. Analysis of three ex-vessel loss-of-coolant accidents in the first wall cooling system of NET/ITER

    International Nuclear Information System (INIS)

    Komen, E.M.J.; Koning, H.

    1993-01-01

    An ex-vessel LOCA may be caused by a rupture of a cooling pipe located outside the vacuum vessel. No plasma shutdown and no other counteractions have been assumed in order to study the worst case conditions of the accidents. The next three ex-vessel LOCAs in the primary cooling system of the first wall have been analysed: 1. a large break ex-vessel LOCA caused by a rupture of the cold leg (inner diameter 0.314 m) of the main circuit; 2. an intermediate break ex-vessel LOCA caused by a rupture of a sector inlet feeder (inner diameter 0.158 m); 3. an intermediate break ex-vessel LOCA caused by a rupture of the surge line (inner diameter 0.180 m) of the pressurizer. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the first two scenarios, melting in the first wall starts about 90 s after break initiation. In the third scenario, melting in the first wall start about 323 s after break initiation. Special emphasis has been paid to the characteristics of the break flows, the transient thermal-hydraulic behaviour of the cooling system, and the temperature development in the first wall. (orig.)

  5. Distribution and natural course of intracranial vessel wall lesions in patients with ischemic stroke or TIA at 7.0 tesla MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kolk, Anja G. van der; Luijten, Peter R.; Hendrikse, Jeroen [University Medical Center Utrecht, Department of Radiology, Postbox 85500, Utrecht (Netherlands); Zwanenburg, Jaco J.M. [University Medical Center Utrecht, Department of Radiology, Postbox 85500, Utrecht (Netherlands); University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Brundel, Manon; Biessels, Geert Jan [University Medical Center Utrecht, Department of Neurology, Utrecht (Netherlands); Visser, Fredy [University Medical Center Utrecht, Department of Radiology, Postbox 85500, Utrecht (Netherlands); Philips Healthcare, Best (Netherlands)

    2015-06-01

    Previous studies using intracranial vessel wall MRI techniques showed that over 50 % of patients with ischemic stroke or TIA had one or more intracranial vessel wall lesions. In the current study, we assessed the preferential location of these lesions within the intracranial arterial tree and their potential changes over time in these patient groups. Forty-nine patients with ischemic stroke (n = 25) or TIA (n = 24) of the anterior cerebral circulation underwent 7.0 T MRI, including a T{sub 1}-weighted magnetization-preparation inversion recovery turbo-spin-echo (MPIR-TSE) sequence within one week and approximately one month after symptom onset. Intracranial vessel wall lesions were scored for multiple locations within the arterial tree and differences between one-week and one-month images. At baseline, 132 intracranial vessel wall lesions were found in 41 patients (84 %), located primarily in the anterior cerebral circulation (74 %), with a preferential location in the distal internal carotid artery and M1 and M2 segments of the middle cerebral artery. During follow-up, presence or enhancement patterns changed in 14 lesions (17 %). A large burden of intracranial vessel wall lesions was found in both the anterior and posterior cerebral circulation. Most lesions were found to be relatively stable, possibly indicating a more generalized atherosclerotic process. (orig.)

  6. Simulation of LLCB TBM in-vessel first wall coolant break into ITER vacuum vessel by using RELAP/MOD3.4

    International Nuclear Information System (INIS)

    Tony Sandeep, K.; Chaudhari, Vilas; Rajendra Kumar, E.; Dutta, Anu; Singh, R.K.

    2013-06-01

    To prove Test Blanket Module (TBM) safety in International Thermonuclear Experimental Reactor (ITER), various accident scenarios are postulated . One of the postulated initiating events to be analysed is TBM First wall (FW) coolant leak in ITER Vacuum vessel (VV). This accident has been classified as a reference event for the TBM (probability of occurrence >1 E -06 /a). The postulated accident occurs as a result of small leak of TBM FW helium into ITER vacuum vessel (VV), caused by the TBM weld failure. The ingress of this TBM FW helium into ITER plasma induces intense plasma disruption that deposits 1.8 MJ/m 2 of plasma stored thermal energy onto the TBM FW over a period of 1 sec in duration (assumption). Runaway electrons in this process are lost from plasma current channel and cause multiple TBM and ITER FW cooling tube failures within 10 cm torriodal strip. The size of the break is identified as double ended rupture of all coolant channels within this strip around the reactor. For LLCB TBM this represents failure of 4 FW channels. The size of ITER FW break is 0.02 m 2 . Consequently, a simultaneous blow down of TBM FW helium and ITER FW water occurs, injecting helium and water into VV. This pressurisation causes the activation of VV pressure suppressions system and ingress of water into VV. This pressurisation causes the VV pressure suppressions system (VVPSS) to open in an attempt to contain the pressure below the safety limit of 0.2 MPa. This report is intended to do the above accident analysis and assessment of active components of TBM using RELAP code and hence prove its safety in ITER environment. (author)

  7. Whole-brain intracranial vessel wall imaging at 3 Tesla using cerebrospinal fluid-attenuated T1-weighted 3D turbo spin echo.

    Science.gov (United States)

    Fan, Zhaoyang; Yang, Qi; Deng, Zixin; Li, Yuxia; Bi, Xiaoming; Song, Shlee; Li, Debiao

    2017-03-01

    Although three-dimensional (3D) turbo spin echo (TSE) with variable flip angles has proven to be useful for intracranial vessel wall imaging, it is associated with inadequate suppression of cerebrospinal fluid (CSF) signals and limited spatial coverage at 3 Tesla (T). This work aimed to modify the sequence and develop a protocol to achieve whole-brain, CSF-attenuated T 1 -weighted vessel wall imaging. Nonselective excitation and a flip-down radiofrequency pulse module were incorporated into a commercial 3D TSE sequence. A protocol based on the sequence was designed to achieve T 1 -weighted vessel wall imaging with whole-brain spatial coverage, enhanced CSF-signal suppression, and isotropic 0.5-mm resolution. Human volunteer and pilot patient studies were performed to qualitatively and quantitatively demonstrate the advantages of the sequence. Compared with the original sequence, the modified sequence significantly improved the T 1 -weighted image contrast score (2.07 ± 0.19 versus 3.00 ± 0.00, P = 0.011), vessel wall-to-CSF contrast ratio (0.14 ± 0.16 versus 0.52 ± 0.30, P = 0.007) and contrast-to-noise ratio (1.69 ± 2.18 versus 4.26 ± 2.30, P = 0.022). Significant improvement in vessel wall outer boundary sharpness was observed in several major arterial segments. The new 3D TSE sequence allows for high-quality T 1 -weighted intracranial vessel wall imaging at 3 T. It may potentially aid in depicting small arteries and revealing T 1 -mediated high-signal wall abnormalities. Magn Reson Med 77:1142-1150, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Imaging the Intracranial Atherosclerotic Vessel Wall Using 7T MRI : Initial Comparison with Histopathology

    NARCIS (Netherlands)

    van der Kolk, A. G.; Zwanenburg, J. J. M.; Denswil, N. P.; Vink, A.; Spliet, W. G. M.; Daemen, M. J. A. P.; Visser, F.; Klomp, D. W. J.; Luijten, P. R.; Hendrikse, J.

    In this preliminary study, 7T imaging was capable of identifying not only intracranial wall thickening but different plaque components such as foamy macrophages and collagen. Signal heterogeneity was typical of advanced atherosclerotic disease. BACKGROUND AND PURPOSE: Several studies have attempted

  9. Strain analysis in CRT candidates using the novel segment length in cine (SLICE) post-processing technique on standard CMR cine images

    International Nuclear Information System (INIS)

    Zweerink, Alwin; Allaart, Cornelis P.; Wu, LiNa; Beek, Aernout M.; Rossum, Albert C. van; Nijveldt, Robin; Kuijer, Joost P.A.; Ven, Peter M. van de; Meine, Mathias; Croisille, Pierre; Clarysse, Patrick

    2017-01-01

    Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. (orig.)

  10. Strain analysis in CRT candidates using the novel segment length in cine (SLICE) post-processing technique on standard CMR cine images

    Energy Technology Data Exchange (ETDEWEB)

    Zweerink, Alwin; Allaart, Cornelis P.; Wu, LiNa; Beek, Aernout M.; Rossum, Albert C. van; Nijveldt, Robin [VU University Medical Center, Department of Cardiology, and Institute for Cardiovascular Research (ICaR-VU), Amsterdam (Netherlands); Kuijer, Joost P.A. [VU University Medical Center, Department of Physics and Medical Technology, Amsterdam (Netherlands); Ven, Peter M. van de [VU University Medical Center, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Meine, Mathias [University Medical Center, Department of Cardiology, Utrecht (Netherlands); Croisille, Pierre; Clarysse, Patrick [Univ Lyon, UJM-Saint-Etienne, INSA, CNRS UMR 5520, INSERM U1206, CREATIS, Saint-Etienne (France)

    2017-12-15

    Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. (orig.)

  11. 1-Dimensional simulation of thermal annealing in a commercial nuclear power plant reactor pressure vessel wall section

    International Nuclear Information System (INIS)

    Nakos, J.T.; Rosinski, S.T.; Acton, R.U.

    1994-11-01

    The objective of this work was to provide experimental heat transfer boundary condition and reactor pressure vessel (RPV) section thermal response data that can be used to benchmark computer codes that simulate thermal annealing of RPVS. This specific protect was designed to provide the Electric Power Research Institute (EPRI) with experimental data that could be used to support the development of a thermal annealing model. A secondary benefit is to provide additional experimental data (e.g., thermal response of concrete reactor cavity wall) that could be of use in an annealing demonstration project. The setup comprised a heater assembly, a 1.2 in x 1.2 m x 17.1 cm thick [4 ft x 4 ft x 6.75 in] section of an RPV (A533B ferritic steel with stainless steel cladding), a mockup of the open-quotes mirrorclose quotes insulation between the RPV and the concrete reactor cavity wall, and a 25.4 cm [10 in] thick concrete wall, 2.1 in x 2.1 in [10 ft x 10 ft] square. Experiments were performed at temperature heat-up/cooldown rates of 7, 14, and 28 degrees C/hr [12.5, 25, and 50 degrees F/hr] as measured on the heated face. A peak temperature of 454 degrees C [850 degrees F] was maintained on the heated face until the concrete wall temperature reached equilibrium. Results are most representative of those RPV locations where the heat transfer would be 1-dimensional. Temperature was measured at multiple locations on the heated and unheated faces of the RPV section and the concrete wall. Incident heat flux was measured on the heated face, and absorbed heat flux estimates were generated from temperature measurements and an inverse heat conduction code. Through-wall temperature differences, concrete wall temperature response, heat flux absorbed into the RPV surface and incident on the surface are presented. All of these data are useful to modelers developing codes to simulate RPV annealing

  12. Characterization of atherosclerotic disease in thoracic aorta: A 3D, multicontrast vessel wall imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Changwu [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Department of Radiology, The Second Clinical Medical College, Yangzhou University, Yangzhou (China); Qiao, Huiyu; He, Le [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Yuan, Chun [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Department of Radiology, University of Washington, Seattle, WA (United States); Chen, Huijun; Zhang, Qiang; Li, Rui [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Wang, Wei; Du, Fang [Department of Radiology, The Second Clinical Medical College, Yangzhou University, Yangzhou (China); Li, Cheng, E-mail: cjr.licheng@vip.163.com [Department of Radiology, Zhongda Hospital, Medical School of Southeast University, Nanjing (China); Zhao, Xihai, E-mail: xihaizhao@tsinghua.edu.cn [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China)

    2016-11-15

    Purpose: To investigate the characteristics of plaque in the thoracic aorta using three dimensional multicontrast magnetic resonance imaging. Materials and methods: Elderly subjects (≥60 years) were recruited in this study. Thoracic aorta was imaged on a 3.0T MR scanner by acquiring multicontrast sequences. The plaque burden was evaluated by measuring lumen area, wall area, wall thickness, and normalized wall index. The presence or absence of plaque and intraplaque hemorrhage (IPH)/mural thrombus (MT) were identified. The characteristics of atherosclerosis among different thoracic aorta segments (AAO: ascending aorta; AOA: aortic arch, and DOA: descending aorta) were determined. Results: Of 66 recruited subjects (mean age 72.3 ± 6.2 years, 30 males), 55 (83.3%) had plaques in the thoracic aorta. The prevalence of plaque in AAO, AOA, and DAO was 5.4%, 72.7%, and 71.2%, respectively. In addition, 21.2% of subjects were found to have lesions with IPH/MT in the thoracic aorta. The prevalence of IPH/MT in segment of AAO, AOA and DAO was 0%, 13.6%, and 12.1%, respectively. The aortic wall showed the highest NWI in DAO (34.1% ± 4.8%), followed by AOA (31.2% ± 5%), and AAO (26.8% ± 3.3%) (p < 0.001). Conclusion: Three dimensional multicontrast MR imaging is capable of characterizing atherosclerotic plaques in the thoracic aorta. The findings of high prevalence of plaques and the presence of high risk plaques in the thoracic aorta suggest early screening for aortic vulnerable lesions in the elderly.

  13. Characterization of atherosclerotic disease in thoracic aorta: A 3D, multicontrast vessel wall imaging study

    International Nuclear Information System (INIS)

    Zhou, Changwu; Qiao, Huiyu; He, Le; Yuan, Chun; Chen, Huijun; Zhang, Qiang; Li, Rui; Wang, Wei; Du, Fang; Li, Cheng; Zhao, Xihai

    2016-01-01

    Purpose: To investigate the characteristics of plaque in the thoracic aorta using three dimensional multicontrast magnetic resonance imaging. Materials and methods: Elderly subjects (≥60 years) were recruited in this study. Thoracic aorta was imaged on a 3.0T MR scanner by acquiring multicontrast sequences. The plaque burden was evaluated by measuring lumen area, wall area, wall thickness, and normalized wall index. The presence or absence of plaque and intraplaque hemorrhage (IPH)/mural thrombus (MT) were identified. The characteristics of atherosclerosis among different thoracic aorta segments (AAO: ascending aorta; AOA: aortic arch, and DOA: descending aorta) were determined. Results: Of 66 recruited subjects (mean age 72.3 ± 6.2 years, 30 males), 55 (83.3%) had plaques in the thoracic aorta. The prevalence of plaque in AAO, AOA, and DAO was 5.4%, 72.7%, and 71.2%, respectively. In addition, 21.2% of subjects were found to have lesions with IPH/MT in the thoracic aorta. The prevalence of IPH/MT in segment of AAO, AOA and DAO was 0%, 13.6%, and 12.1%, respectively. The aortic wall showed the highest NWI in DAO (34.1% ± 4.8%), followed by AOA (31.2% ± 5%), and AAO (26.8% ± 3.3%) (p < 0.001). Conclusion: Three dimensional multicontrast MR imaging is capable of characterizing atherosclerotic plaques in the thoracic aorta. The findings of high prevalence of plaques and the presence of high risk plaques in the thoracic aorta suggest early screening for aortic vulnerable lesions in the elderly.

  14. Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing (CS-SPACE).

    Science.gov (United States)

    Zhu, Chengcheng; Tian, Bing; Chen, Luguang; Eisenmenger, Laura; Raithel, Esther; Forman, Christoph; Ahn, Sinyeob; Laub, Gerhard; Liu, Qi; Lu, Jianping; Liu, Jing; Hess, Christopher; Saloner, David

    2018-06-01

    Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging. A 3D accelerated T 1 -weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T. Both the acquisition [echo train length (ETL), under-sampling factor] and reconstruction parameters (regularization parameter, number of iterations) were first optimized in 5 healthy volunteers. Ten patients with a variety of intracranial vascular disease presentations (aneurysm, atherosclerosis, dissection, vasculitis) were imaged with SPACE and optimized CS-SPACE, pre and post Gd contrast. Lumen/wall area, wall-to-lumen contrast ratio (CR), enhancement ratio (ER), sharpness, and qualitative scores (1-4) by two radiologists were recorded. The optimized CS-SPACE protocol has ETL 60, 20% k-space under-sampling, 0.002 regularization factor with 20 iterations. In patient studies, CS-SPACE and conventional SPACE had comparable image scores both pre- (3.35 ± 0.85 vs. 3.54 ± 0.65, p = 0.13) and post-contrast (3.72 ± 0.58 vs. 3.53 ± 0.57, p = 0.15), but the CS-SPACE acquisition was 37% faster (6:48 vs. 10:50). CS-SPACE agreed with SPACE for lumen/wall area, ER measurements and sharpness, but marginally reduced the CR. In the evaluation of intracranial vascular disease, CS-SPACE provides a substantial reduction in scan time compared to conventional T 1 -weighted SPACE while maintaining good image quality.

  15. Strain analysis in CRT candidates using the novel segment length in cine (SLICE) post-processing technique on standard CMR cine images.

    Science.gov (United States)

    Zweerink, Alwin; Allaart, Cornelis P; Kuijer, Joost P A; Wu, LiNa; Beek, Aernout M; van de Ven, Peter M; Meine, Mathias; Croisille, Pierre; Clarysse, Patrick; van Rossum, Albert C; Nijveldt, Robin

    2017-12-01

    Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. • Myocardial strain analysis could potentially improve patient selection for CRT. • Currently a well validated clinical approach to derive segmental strains is lacking. • The novel SLICE technique derives segmental strains from standard CMR cine images. • SLICE-derived strain markers of CRT response showed close agreement with CMR-TAG. • Future studies will focus on the prognostic value of SLICE in CRT candidates.

  16. Finite element analysis of the design and manufacture of thin-walled pressure vessels used as aerosol cans

    Science.gov (United States)

    Abdussalam, Ragba Mohamed

    Thin-walled cylinders are used extensively in the food packaging and cosmetics industries. The cost of material is a major contributor to the overall cost and so improvements in design and manufacturing processes are always being sought. Shape optimisation provides one method for such improvements. Aluminium aerosol cans are a particular form of thin-walled cylinder with a complex shape consisting of truncated cone top, parallel cylindrical section and inverted dome base. They are manufactured in one piece by a reverse-extrusion process, which produces a vessel with a variable thickness from 0.31 mm in the cylinder up to 1.31 mm in the base for a 53 mm diameter can. During manufacture, packaging and charging, they are subjected to pressure, axial and radial loads and design calculations are generally outside the British and American pressure vessel codes. 'Design-by-test' appears to be the favoured approach. However, a more rigorous approach is needed in order to optimise the designs. Finite element analysis (FEA) is a powerful tool for predicting stress, strain and displacement behaviour of components and structures. FEA is also used extensively to model manufacturing processes. In this study, elastic and elastic-plastic FEA has been used to develop a thorough understanding of the mechanisms of yielding, 'dome reversal' (an inherent safety feature, where the base suffers elastic-plastic buckling at a pressure below the burst pressure) and collapse due to internal pressure loading and how these are affected by geometry. It has also been used to study the buckling behaviour under compressive axial loading. Furthermore, numerical simulations of the extrusion process (in order to investigate the effects of tool geometry, friction coefficient and boundary conditions) have been undertaken. Experimental verification of the buckling and collapse behaviours has also been carried out and there is reasonable agreement between the experimental data and the numerical

  17. 3-D MDT with spherical targets by bilinear interpolation for determining blood velocity profiles including the vessel wall effect

    Science.gov (United States)

    Choomphon-anomakhun, Natthaphon; Natenapit, Mayuree

    2018-02-01

    A numerical simulation of three-dimensional (3-D) implant assisted-magnetic drug targeting (IA-MDT) using ferromagnetic spherical targets, including the effect from the vessel wall on the blood flow, is presented. The targets were implanted within arterioles and subjected to an externally uniform applied magnetic field in order to increase the effectiveness of targeting magnetic drug carrier particles (MDCPs). The capture area (As) of the MDCPs was determined by inspection of the particle trajectories simulated from the particle equations of motion. The blood flow velocities at any particle position around the target were obtained by applying bilinear interpolation to the numerical blood velocity data. The effects on As of the type of ferromagnetic materials in the targets and MDCPs, average blood flow rates, mass fraction of the ferromagnetic material in the MDCPs, average radii of MDCPs (Rp) and the externally applied magnetic field strength (μ0H0) were evaluated. Furthermore, the appropriate μ0H0 and Rp for the IA-MDT design is suggested. In the case of the SS409 target and magnetite MDCPs, dimensionless capture areas ranging from 4.1- to 12.4 and corresponding to particle capture efficiencies of 31-94% were obtained with Rp ranging from 100- to 500 nm, weight fraction of 80%, μ0H0 of 0.6 T and an average blood flow rate of 0.01 ms-1. In addition, the more general 3-D modelling of IA-MDT in this work is applicable to IA-MDT using spherical targets implanted within blood vessels for both laminar and potential blood flows including the wall effect.

  18. 18F-fluoroethylcholine uptake in arterial vessel walls and cardiovascular risk factors. Correlation in a PET-CT study

    International Nuclear Information System (INIS)

    Foerster, Stefan; Rominger, A.; Cumming, P.; Bartenstein, P.; Hacker, M.; Saam, T.; Nikolaou, K.; Reiser, M.F.; Wolpers, S.; Univ. Muenchen

    2010-01-01

    Fluorine-labelled choline derivatives were recently suggested as agents for visualizing vulnerable atherosclerotic plaques. We therefore aimed to evaluate the association between 18 F-fluorethylcholine (FEC) uptake in the wall of large arteries, where calcification was also measured, with the presence of cardiovascular risk factors and occurrence of prior cardiovascular events. Detailed clinical information, including common cardiovascular risk factors, was obtained retrospectively in 60 prostate cancer patients examined with whole-body FEC PET-CT. In each patient, we calculated the mean blood pool-corrected SUV, as well as the mean target-to-background ratio (TBR), in addition to the sum of calcified plaques (CP sum ) from six major vessels: ascending and descending aorta, aortic arch, abdominal aorta, and both iliac arteries. As reported previously, the CP sum correlated significantly with cardiovascular risk factors, in contrast to mean SUV or TBR scores, which did not show any significance with the presence of cardiovascular risk factors. There was no correlation between CP sum , mean TBR or SUV, nor was there any significant association of CP sum , mean TBR or SUV with the prior occurrence of cardio- or cerebrovascular events. Contrary to a recent report, we found in our rather large cohort of elderly prostate cancer patients no significant association between FEC uptake in large vessels and atherosclerotic plaque burden, or the presence of cardiovascular risk factors. In line with prior reports on structural changes in vessels, increased calcified atherosclerotic plaque burden was strongly associated with the occurrence of common cardiovascular risk factors. (orig.)

  19. Development of a system for measuring wall shear stress in blood vessels using magnetic resonance imaging and computational fluid dynamics

    International Nuclear Information System (INIS)

    Yoshida, Keita; Nagao, Taisuke; Okada, Kouji; Miyazaki, Shohei; Yang, Xiaomei; Yamazaki, Youichi; Murase, Kenya

    2008-01-01

    We developed a system for measuring the wall shear stress (WSS) in blood vessels using magnetic resonance imaging (MRI) and computational fluid dynamics (CFD). The time-dependent velocity at the center of the blood vessel was measured by phase-contrast MRI and was approximated by finite Fourier series, which was used for generating the velocity profile at the inlet for the boundary condition to the CFD method. To validate the CFD method, we compared the WSS obtained by the CFD method with the theoretical value in a straight cylinder with various radii for both steady and pulsatile flows. We also investigated the dependence of the WSS on the inlet velocity profile incorporated into the CFD method. For steady flow, there was a good agreement between the WSS obtained by the CFD method and the theoretical value. For pulsatile flow, there was a relatively good agreement between them when the radius of the cylinder was 2.5 mm and the inlet velocity profile was given by the Womersley solution for fully developed pulsatile flow in a straight circular cylinder. When the radius of the cylinder was 5 mm and/or the inlet velocity profile was assumed to be parabolic, large differences were observed between them, suggesting that the assumption of fully developed flow does not hold true in these cases. In human studies, the vortex due to the secondary blood flow in the carotid arterial sinus was clearly observed. The WSS in the bifurcation was the highest, while that in the carotid arterial sinus was the smallest. In conclusion, the system presented here appears to be useful for measuring the WSS in blood vessels and for analyzing the cause and/or extent of atherosclerosis, and our results suggest that the inlet velocity profile should be carefully considered. (author)

  20. Feature tracking CMR reveals abnormal strain in preclinical arrhythmogenic right ventricular dysplasia/ cardiomyopathy: a multisoftware feasibility and clinical implementation study.

    Science.gov (United States)

    Bourfiss, Mimount; Vigneault, Davis M; Aliyari Ghasebeh, Mounes; Murray, Brittney; James, Cynthia A; Tichnell, Crystal; Mohamed Hoesein, Firdaus A; Zimmerman, Stefan L; Kamel, Ihab R; Calkins, Hugh; Tandri, Harikrishna; Velthuis, Birgitta K; Bluemke, David A; Te Riele, Anneline S J M

    2017-09-01

    Regional right ventricular (RV) dysfunction is the hallmark of Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy (ARVD/C), but is currently only qualitatively evaluated in the clinical setting. Feature Tracking Cardiovascular Magnetic Resonance (FT-CMR) is a novel quantitative method that uses cine CMR to calculate strain values. However, most prior FT-CMR studies in ARVD/C have focused on global RV strain using different software methods, complicating implementation of FT-CMR in clinical practice. We aimed to assess the clinical value of global and regional strain using FT-CMR in ARVD/C and to determine differences between commercially available FT-CMR software packages. We analyzed cine CMR images of 110 subjects (39 overt ARVD/C [mutation+/phenotype+], 40 preclinical ARVD/C [mutation+/phenotype-] and 31 control) for global and regional (subtricuspid, anterior, apical) RV strain in the horizontal longitudinal axis using four FT-CMR software methods (Multimodality Tissue Tracking, TomTec, Medis and Circle Cardiovascular Imaging). Intersoftware agreement was assessed using Bland Altman plots. For global strain, all methods showed reduced strain in overt ARVD/C patients compared to control subjects (p  0.275). For regional strain, overt ARVD/C patients showed reduced strain compared to control subjects in all segments which reached statistical significance in the subtricuspid region for all software methods (p < 0.037), in the anterior wall for two methods (p < 0.005) and in the apex for one method (p = 0.012). Preclinical subjects showed abnormal subtricuspid strain compared to control subjects using one of the software methods (p = 0.009). Agreement between software methods for absolute strain values was low (Intraclass Correlation Coefficient = 0.373). Despite large intersoftware variability of FT-CMR derived strain values, all four software methods distinguished overt ARVD/C patients from control subjects by both global and subtricuspid

  1. Rôle of contrast media viscosity in altering vessel wall shear stress and relation to the risk of contrast extravasations.

    Science.gov (United States)

    Sakellariou, Sophia; Li, Wenguang; Paul, Manosh C; Roditi, Giles

    2016-12-01

    Iodinated contrast media (CM) are the most commonly used injectables in radiology today. A range of different media are commercially available, combining various physical and chemical characteristics (ionic state, osmolality, viscosity) and thus exhibiting distinct in vivo behaviour and safety profiles. In this paper, numerical simulations of blood flow with contrast media were conducted to investigate the effects of contrast viscosity on generated vessel wall shear stress and vessel wall pressure to elucidate any possible relation to extravasations. Five different types of contrast for Iodine fluxes ranging at 1.5-2.2gI/s were modelled through 18G and 20G cannulae placed in an ideal vein at two different orientation angles. Results demonstrate that the least viscous contrast media generate the least maximum wall shear stress as well as the lowest total pressure for the same flow rate. This supports the empirical clinical observations and hypothesis that more viscous contrast media are responsible for a higher percentage of contrast extravasations. In addition, results support the clinical hypothesis that a catheter tip directed obliquely to the vein wall always produces the highest maximum wall shear stress and total pressure due to impingement of the contrast jet on the vessel wall. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Detection of a coronary artery vessel wall: performance of 0.3 mm fine-cell detector computed tomography-a phantom study

    International Nuclear Information System (INIS)

    Yamada, Minoru; Jinzaki, Masahiro; Tanami, Yutaka; Matsumoto, Kazuhiro; Ueno, Akihisa; Kuribayashi, Sachio; Nukui, Masatake; Imai, Yasuhiro; Ishihara, Yotaro; Nishide, Akihiko; Sasaki, Kosuke

    2011-01-01

    The purpose of this study was to evaluate whether experimental fine-cell detector computed tomography with a 0.3125 mm cell (0.3 mm cell CT) can improve the detection of coronary vessel walls compared with conventional 64-slice computed tomography with a 0.625 mm cell (0.6 mm cell CT). A coronary vessel wall phantom was scanned using 0.6 mm cell CT and 0.3 mm cell CT. The data for 0.3 mm cell CT were obtained using four protocols: a radiation dose equal, double, triple or quadruple that were used in the 0.6 mm cell CT protocol. The detectable size of the vessel wall was assessed based on the first and second derivative functions, and the minimum measurable values were compared using a paired t-test. As a result, the minimum detectable wall thickness of 0.6 mm cell CT (1.5 mm) was significantly larger than that of 0.3 mm cell CT performed using the triple- and quadruple-dose protocols (0.9 mm) and the double-dose protocol (1.1 mm). The difference in the minimum detectable vessel wall thickness measured using 0.6 mm cell CT (1.5 ± 0.1 mm) and 0.3 mm cell CT (0.9 ± 0.1 mm, 1.1 ± 0.2 mm) was significant (p < 0.01). We concluded that 0.3 mm cell CT improved the detection of coronary vessel walls when a more than double-dose protocol was used compared with 0.6 mm cell CT.

  3. Detection of vessel wall calcifications in vertebral arteries using susceptibility weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Lisa C.; Boeker, Sarah M.; Bender, Yvonne Y.; Fallenberg, Eva M.; Wagner, Moritz; Hamm, Bernd; Makowski, Marcus R. [Department of Radiology, Charite, Berlin (Germany); Liebig, Thomas [Department of Neuroradiology, Charite, Berlin (Germany)

    2017-09-15

    Calcification of the brain supplying arteries has been linked to an increased risk for cerebrovascular disease. The purpose of this study was to test the potential of susceptibility weighted MR imaging (SWMR) for the detection of vertebral artery calcifications, based on CT as a reference standard. Four hundred seventy-four patients, who had received head CT and 1.5 T MR scans with SWMR, including the distal vertebral artery, between January 2014 and December 2016, were retrospectively evaluated and 389 patients were included. Sensitivity and specificity for the detection of focal calcifications and intra- and interobserver agreement were calculated for SWMR and standard MRI, using CT as a standard of reference. The diameter of vertebral artery calcifications was used to assess correlations between imaging modalities. Furthermore, the degree of vessel stenosis was determined in 30 patients, who had received an additional angiography. On CT scans, 40 patients showed a total of 52 vertebral artery calcifications. While SWMR reached a sensitivity of 94% (95% CI 84-99%) and a specificity of 97% (95% CI 94-98%), standard MRI yielded a sensitivity of 33% (95% CI 20-46%), and a specificity of 93% (95% CI 90-96%). Linear regression analysis of size measurements confirmed a close correlation between SWMR and CT measurements (R {sup 2} = 0.74, p < 0.001). Compared to standard MRI (ICC = 0.52; CI 0.45-0.59), SWMR showed a higher interobserver agreement for calcification measurements (ICC = 0.84; CI 0.81-0.87). For detection of distal vertebral artery calcifications, SWMR demonstrates a performance comparable to CT and considerably higher than conventional MRI. (orig.)

  4. Structural design of shield-integrated thin-wall vacuum vessel and manufacturing qualification tests for International Thermonuclear Experimental Reactor (ITER)

    International Nuclear Information System (INIS)

    Shimizu, Katsusuke; Shibui, Masanao; Koizumi, Koichi; Kanamori, Naokazu; Nishio, Satoshi; Sasaki, Takashi; Tada, Eisuke

    1992-09-01

    Conceptual design of shield-integrated thin-wall vacuum vessel has been done for ITER (International Thermonuclear Experimental Reactor). The vacuum vessel concept is based on a thin-double-wall structure, which consists of inner and outer plates and rib stiffeners. Internal shielding structures, which provide neutron irradiation shielding to protect TF coils, are set up between the inner plate and the outer plate of the vessel to avoid complexity of machine systems such as supporting systems of blanket modules. The vacuum vessel is assembled/disassembled by remote handling, so that welding joints are chosen as on-site joint method from reliability of mechanical strength. From a view point of assembling TF coils, the vacuum vessel is separated at the side of port, and is divided into 32 segments similar to the ITER-CDA reference design. Separatrix sweeping coils are located in the vacuum vessel to reduce heat fluxes onto divertor plates. Here, the coil structure and attachment to the vacuum vessel have been investigated. A sectorized saddle-loop coil is available for assembling and disassembling the coil. To support electromagnetic loads on the coils, they are attached to the groove in the vacuum vessel by welding. Flexible multi-plate supporting structure (compression-type gravity support), which was designed during CDA, is optimized by investigating buckling and frequency response properties, and concept on manufacturing and fabrication of the gravity support are proposed. Partial model of the vacuum vessel is manufactured for trial, so that fundamental data on welding and fabrication are obtained. From mechanical property tests of weldment and partial models, mechanical intensity and behaviors of the weldment are obtained. Informations on FEM-modeling are obtained by comparing analysis results with experimental results. (author)

  5. [Morphological signs of mitochondrial cytopathy in skeletal muscles and micro-vessel walls in a patient with cerebral artery dissection associated with MELAS syndrome].

    Science.gov (United States)

    Sakharova, A V; Kalashnikova, L A; Chaĭkovskaia, R P; Mir-Kasimov, M F; Nazarova, M A; Pykhtina, T N; Dobrynina, L A; Patrusheva, N L; Patrushev, L I; Protskiĭ, S V

    2012-01-01

    Skin and muscles biopsy specimens of a patient harboring A3243G mutation in mitochondrial DNA, with dissection of internal carotid and vertebral arteries, associated with MELAS were studied using histochemical and electron-microscopy techniques. Ragged red fibers, regional variability of SDH histochemical reaction, two types of morphologically atypical mitochondria and their aggregation were found in muscle. There was correlation between SDH histochemical staining and number of mitochondria revealed by electron microscopy in muscle tissue. Similar mitochondrial abnormality, their distribution and cell lesions followed by extra-cellular matrix mineralization were found in the blood vessel walls. In line with generalization of cytopathy process caused by gene mutation it can be supposed that changes found in skin and muscle microvessels also exist in large cerebral vessels causing the vessel wall "weakness", predisposing them to dissection.

  6. Laboratory feasibility study of fusion vessel inner wall chemical analysis by Laser Induced Breakdown Spectroscopy

    International Nuclear Information System (INIS)

    Almaviva, Salvatore; Caneve, Luisa; Colao, Francesco; Fantoni, Roberta; Maddaluno, Giorgio

    2012-01-01

    Graphical abstract: Laser-Induced-Breakdown-Spectroscopy was used for the determination of the atomic composition of multilayered samples simulating the tiles of plasma facing components in the next generation fusion machines. Highlights: ► Description and characterization of an LIBS set-up for diagnostics in fusion machines. ► Identification of atomic composition of multilayered tiles simulating plasma facing components. ► Qualitative applicability of the Calibration Free method for quantitative analysis. ► Feasibility of large scale application in the processes of control during the tiles fabrication. ► Feasibility of erosion monitoring during operation of fusion machines. - Abstract: Laser Induced Breakdown Spectroscopy (LIBS) is nowadays a well established tool for qualitative, semi-quantitative and quantitative analyses of surfaces, with micro-destructive characteristics and capabilities for stratigraphy. LIBS is an appealing technique compared with many other types of elemental analysis thanks to the set up versatility facilitating non-invasive and remote analyses, as well as suitability to diagnostics in harsh environments. In this work, LIBS capabilities were used for the determination of the atomic composition of multilayered samples simulating the tiles of plasma facing components in the next generation fusion machines such as ITER. A new experimental setup was designed and realized in order to optimize the characteristics of an LIBS system working at low pressure and remotely, as it should be for an in situ system to be applied in monitoring the erosion and redeposition phenomena occurring on the inner walls of a fusion device. The effects of time delay and laser fluence on LIBS sensitivity at reduced pressure were examined, looking for operational conditions suitable to analytical applications. The quantitative analysis of some atomic species in the superficial layer has been carried out using a Calibration Free (CF) approach in the time

  7. Study of the CMR compounds in hazardous wastes

    International Nuclear Information System (INIS)

    Chollot, A.

    2007-01-01

    In order to limit the exposure of workers to carcinogenic, mutagen and reproduction-toxic compounds (CMR) and to optimize the safety needs in the field of hazardous industrial wastes, the INRS has decided to complete its knowledge in doing a sectorial inquiry titled 'study of the CMR compounds contained in wastes'. This study allows to obtain data relative to hazardous wastes and to the presence of CMR compounds into these hazardous wastes. The first part of this study gives the methodology used for doing this inquiry. The results, gathered in databases, are presented in tables and in synthetic schemes. The last part gives operational propositions it could be important to adopt to improve and/or to develop safety approaches adapted to the CMR risk and, particularly the transfer of the good data to workers. (O.M.)

  8. High-resolution neutron powder-diffraction in CMR manganates

    Energy Technology Data Exchange (ETDEWEB)

    Suard, E; Radaelli, P G [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France)

    1997-04-01

    Manganese-oxide materials have recently been the subject of renewed attention, due to the `colossal` magnetoresistance (CMR) displayed near the spin-ordering temperature T{sub c} by some of these compounds. CMR has been evidenced in at least three families of manganese oxides. In most cases, the CMR compounds behave as paramagnetic semiconductors at high temperatures, and as ferromagnetic metals below T{sub c}. The study of this metallization process has lead some theorists to challenge its traditional interpretation in terms of the so-called double-exchange mechanism, and to propose alternative scenarios in which the coupling of the charge carriers with the lattice plays a paramount role. Powder diffraction method, being at the forefront of CMR research is presented. (author). 4 refs.

  9. Non-gated vessel wall imaging of the internal carotid artery using radial scanning and fast spin echo sequence. Evaluation of vessel signal intensity by flow rate at 3.0 tesla

    International Nuclear Information System (INIS)

    Nakamura, Manami; Makabe, Takeshi; Ichikawa, Masaki; Hatakeyama, Ryohei; Sugimori, Hiroyuki; Sakata, Motomichi

    2013-01-01

    Vessel wall imaging using radial scanning does not use a blood flow suppression pulse with gated acquisition. It has been proposed that there may not be a flow void effect if the flow rate is slow; however, this has yet to be empirically tested. To clarify the relationship between the signal intensity of the vessel lumen and the blood flow rate in a flow phantom, we investigated the usefulness of vessel wall imaging at 3.0 tesla (T). We measured the signal intensity while changing the flow rate in the flow phantom. Radial scanning at 1.5 T showed sufficient flow voids at above medium flow rates. There was no significant difference in lumen signal intensity at the carotid artery flow rate. The signal intensity of the vessel lumen decreased sufficiently using the radial scan method at 3.0 T. We thus obtained sufficient flow void effects at the carotid artery flow rate. We conclude this technique to be useful for evaluating plaque if high contrast can be maintained for fixed tissue (such as plaque) and the vessel lumen. (author)

  10. Achieving Sub-Second Search in the CMR

    Science.gov (United States)

    Gilman, J.; Baynes, K.; Pilone, D.; Mitchell, A. E.; Murphy, K. J.

    2014-12-01

    The Common Metadata Repository (CMR) is the next generation Earth Science Metadata catalog for NASA's Earth Observing data. It joins together the holdings from the EOS Clearing House (ECHO) and the Global Change Master Directory (GCMD), creating a unified, authoritative source for EOSDIS metadata. The CMR allows ingest in many different formats while providing consistent search behavior and retrieval in any supported format. Performance is a critical component of the CMR, ensuring improved data discovery and client interactivity. The CMR delivers sub-second search performance for any of the common query conditions (including spatial) across hundreds of millions of metadata granules. It also allows the addition of new metadata concepts such as visualizations, parameter metadata, and documentation. The CMR's goals presented many challenges. This talk will describe the CMR architecture, design, and innovations that were made to achieve its goals. This includes: * Architectural features like immutability and backpressure. * Data management techniques such as caching and parallel loading that give big performance gains. * Open Source and COTS tools like Elasticsearch search engine. * Adoption of Clojure, a functional programming language for the Java Virtual Machine. * Development of a custom spatial search plugin for Elasticsearch and why it was necessary. * Introduction of a unified model for metadata that maps every supported metadata format to a consistent domain model.

  11. Atomic and microstructure of CMR materials

    International Nuclear Information System (INIS)

    Van Tendeloo, G.; Lebedev, O.I.; Amelinckx, S.

    2000-01-01

    The local structure of bulk and thin films of different perovskite-based CMR materials has been studied by high-resolution electron microscopy. The structure of Ln 1-x A x MnO 3 is not only a function of temperature and A-doping, but also of the thickness of the film. Evidence is produced for a slight monoclinic distortion at room temperature in most Ln 1-x A x MnO 3 compounds. For epitaxial La 0.7 Sr 0.3 MnO 3 (LSMO) films on a LaAlO 3 (0 0 1) the evolution of stress in the film is studied as a function of film thickness and thermal treatment. Close to the interface both film and substrate are elastically strained in opposite sense such that the interface is perfectly coherent for thin films not exceeding 30-35 nm. In thicker films the stress is partially relieved after annealing by the formation of misfit dislocations with an edge character. Thin films of La 1-x Ca x MnO 3 on a SrTiO 3 substrate, exhibit a remarkable microstructure. In direct contact with the SrTiO 3 substrate a thin featureless perfectly coherent La 1-x Ca x MnO 3 layer is formed. Subsequently, on top of this first layer a second thicker layer is deposited; it has a columnar microstructure. These columns, parallel to the interface normal, are in fact prismatic anti-phase domains. Their formation is attributed to the introduction of chemical faults during the film growth process. Islands of rocksalt-type MnO structure, nucleated within the regular La-O layer of the LCMO structure, initiate the formation of the prismatic anti-phase domains. Models of the domain boundaries and of the interface film/substrate are proposed. A growth mechanism for the domain structure is suggested

  12. Neutron fluence at the reactor pressure vessel wall - a comparison of French and German procedures and strategies in PWRs

    International Nuclear Information System (INIS)

    Tricot, N.; Jendrich, U.

    2003-01-01

    While the neutrons within the core may take part in the chain reaction, those neutrons emitted from the core are basically lost for the energy production. This 'neutron leakage' represents a loss of fuel efficiency and causes neutron embrittlement of the reactor pressure vessel (RPV) wall. The latter raises safety concerns, needs to be monitored closely and may necessitate mitigating measures. There are different strategies to deal with these two undesirable effects: The neutron emission may be reduced to some extent all around the core or just at the 'hot spots' of RPV embrittlement by tailored core loading patterns. A higher absorption rate of neutrons may also be achieved by a larger water gap between the core and the RPV. In this paper the inter-relations between the distribution of neutron flux, core geometry, core loading strategy, RPV embrittlement and its surveillance are discussed at first. Then the different strategies followed by the German and French operators are described. Finally the conclusions will highlight the communalities and differences between these strategies as different approaches to the same problem of safety as well as economy. (authors)

  13. In vivo and in vitro methods to study platelet adhesion to the components of the vessel wall

    International Nuclear Information System (INIS)

    Cazenave, J.-P.

    1979-01-01

    The methods that are used to measure platelet adhesion can be divided in five groups: methods that use an aggregometer to measure platelet adhesion to collagen in the presence of EDTA; methods that use binding of radiolabeled collagen, affinity chromatography, or gel filtration; the morphometric method of Baumgartner that measures platelet interaction with the subendothelium of an aorta exposed to flow in an annular perfusion chamber; the quantitative isotopic measurement of platelet adhesion to collagen-coated surfaces and to subendothelium with the rotating probe device of Cazenave; and in vivo platelet adhesion to the subendothelium measured by the morphometric method or with platelets radiolabeled with 51 Cr or 111 In. With these methods it has been possible to study the factors (Ca 2+ ; VIII: von Willebrand factor; hemodynamic factors: red cells, shear rate; components of the vessel wall) governing platelet adhesion to subendothelium and to collagen. It has also been possible to screen and study drugs inhibiting platelet adhesion, which is the first step in the formation of a thrombus at the site of vascular injury [fr

  14. Accelerated and Improved Differentiation of Retinal Organoids from Pluripotent Stem Cells in Rotating-Wall Vessel Bioreactors

    Directory of Open Access Journals (Sweden)

    Tyler DiStefano

    2018-01-01

    Full Text Available Pluripotent stem cells can be differentiated into 3D retinal organoids, with major cell types self-patterning into a polarized, laminated architecture. In static cultures, organoid development may be hindered by limitations in diffusion of oxygen and nutrients. Herein, we report a bioprocess using rotating-wall vessel (RWV bioreactors to culture retinal organoids derived from mouse pluripotent stem cells. Organoids in RWV demonstrate enhanced proliferation, with well-defined morphology and improved differentiation of neurons including ganglion cells and S-cone photoreceptors. Furthermore, RWV organoids at day 25 (D25 reveal similar maturation and transcriptome profile as those at D32 in static culture, closely recapitulating spatiotemporal development of postnatal day 6 mouse retina in vivo. Interestingly, however, retinal organoids do not differentiate further under any in vitro condition tested here, suggesting additional requirements for functional maturation. Our studies demonstrate that bioreactors can accelerate and improve organoid growth and differentiation for modeling retinal disease and evaluation of therapies.

  15. Thermodynamic Alloy Design of High Strength and Toughness in 300 mm Thick Pressure Vessel Wall of 1.25Cr-0.5Mo Steel

    Directory of Open Access Journals (Sweden)

    Hye-sung Na

    2018-01-01

    Full Text Available In the 21st century, there is an increasing need for high-capacity, high-efficiency, and environmentally friendly power generation systems. The environmentally friendly integrated gasification combined-cycle (IGCC technology has received particular attention. IGCC pressure vessels require a high-temperature strength and creep strength exceeding those of existing pressure vessels because the operating temperature of the reactor is increased for improved capacity and efficiency. Therefore, high-pressure vessels with thicker walls than those in existing pressure vessels (≤200 mm must be designed. The primary focus of this research is the development of an IGCC pressure vessel with a fully bainitic structure in the middle portion of the 300 mm thick Cr-Mo steel walls. For this purpose, the effects of the alloy content and cooling rates on the ferrite precipitation and phase transformation behaviors were investigated using JMatPro modeling and thermodynamic calculation; the results were then optimized. Candidate alloys from the simulated results were tested experimentally.

  16. Structural Properties of EB-Welded AlSi10Mg Thin-Walled Pressure Vessels Produced by AM-SLM Technology

    Science.gov (United States)

    Nahmany, Moshe; Stern, Adin; Aghion, Eli; Frage, Nachum

    2017-10-01

    Additive manufacturing of metals by selective laser melting (AM-SLM) is hampered by significant limitations in product size due to the limited dimensions of printing trays. Electron beam welding (EBW) is a well-established process that results in relatively minor metallurgical modifications in workpieces due to the ability of EBW to pass high-density energy to the related substance. The present study aims to evaluate structural properties of EB-welded AlSi10Mg thin-walled pressure vessels produced from components prepared by SLM technology. Following the EB welding process, leak and burst tests were conducted, as was fractography analysis. The welded vessels showed an acceptable holding pressure of 30 MPa, with a reasonable residual deformation up to 2.3% and a leak rate better than 1 × 10-8 std-cc s-1 helium. The failures that occurred under longitudinal stresses reflected the presence of two weak locations in the vessels, i.e., the welded joint region and the transition zone between the vessel base and wall. Fractographic analysis of the fracture surfaces of broken vessels displayed the ductile mode of the rupture, with dimples of various sizes, depending on the failure location.

  17. Cardiac involvement in patients with Becker muscular dystrophy: new diagnostic and pathophysiological insights by a CMR approach

    Directory of Open Access Journals (Sweden)

    Thiene Gaetano

    2008-11-01

    Full Text Available Abstract Background Becker-Kiener muscular dystrophy (BMD represents an X-linked genetic disease associated with myocardial involvement potentially resulting in dilated cardiomyopathy (DCM. Early diagnosis of cardiac involvement may permit earlier institution of heart failure treatment and extend life span in these patients. Both echocardiography and nuclear imaging methods are capable of detecting later stages of cardiac involvement characterised by wall motion abnormalities. Cardiovascular magnetic resonance (CMR has the potential to detect cardiac involvement by depicting early scar formation that may appear before onset of wall motion abnormalities. Methods In a prospective two-center-study, 15 male patients with BMD (median age 37 years; range 11 years to 56 years underwent comprehensive neurological and cardiac evaluations including physical examination, echocardiography and CMR. A 16-segment model was applied for evaluation of regional wall motion abnormalities (rWMA. The CMR study included late gadolinium enhancement (LGE imaging with quantification of myocardial damage. Results Abnormal echocardiographic results were found in eight of 15 (53.3% patients with all of them demonstrating reduced left ventricular ejection fraction (LVEF and rWMA. CMR revealed abnormal findings in 12 of 15 (80.0% patients (p = 0.04 with 10 (66.6% having reduced LVEF (p = 0.16 and 9 (64.3% demonstrating rWMA (p = 0.38. Myocardial damage as assessed by LGE-imaging was detected in 11 of 15 (73.3% patients with a median myocardial damage extent of 13.0% (range 0 to 38.0%, an age-related increase and a typical subepicardial distribution pattern in the inferolateral wall. Ten patients (66.7% were in need of medical heart failure therapy based on CMR results. However, only 4 patients (26.7% were already taking medication based on clinical criteria (p = 0.009. Conclusion Cardiac involvement in patients with BMD is underdiagnosed by echocardiographic methods resulting

  18. Assessing the feasibility of a high-temperature, helium-cooled vacuum vessel and first wall for the Vulcan tokamak conceptual design

    International Nuclear Information System (INIS)

    Barnard, H.S.; Hartwig, Z.S.; Olynyk, G.M.; Payne, J.E.

    2012-01-01

    The Vulcan conceptual design (R = 1.2 m, a = 0.3 m, B 0 = 7 T), a compact, steady-state tokamak for plasma–material interaction (PMI) science, must incorporate a vacuum vessel capable of operating at 1000 K in order to replicate the temperature-dependent physical chemistry that will govern PMI in a reactor. In addition, the Vulcan divertor must be capable of handling steady-state heat fluxes up to 10 MW m −2 so that integrated materials testing can be performed under reactor-relevant conditions. A conceptual design scoping study has been performed to assess the challenges involved in achieving such a configuration. The Vulcan vacuum system comprises an inner, primary vacuum vessel that is thermally and mechanically isolated from the outer, secondary vacuum vessel by a 10 cm vacuum gap. The thermal isolation minimizes heat conduction between the high-temperature helium-cooled primary vessel and the water-cooled secondary vessel. The mechanical isolation allows for thermal expansion and enables vertical removal of the primary vessel for maintenance or replacement. Access to the primary vessel for diagnostics, lower hybrid waveguides, and helium coolant is achieved through ∼1 m long intra-vessel pipes to minimize temperature gradients and is shown to be commensurate with the available port space in Vulcan. The isolated primary vacuum vessel is shown to be mechanically feasible and robust to plasma disruptions with analytic calculations and finite element analyses. Heat removal in the first wall and divertor, coupled with the ability to perform in situ maintenance and replacement of divertor components for scientific purposes, is achieved by combining existing helium-cooled techniques with innovative mechanical attachments of plasma facing components, either in plate-type helium-cooled modules or independently bolted, helium-jet impingement-cooled tiles. The vacuum vessel and first wall design enables a wide range of potential PFC materials and configurations to

  19. Differentiation of deep subcortical infarction using high-resolution vessel wall MR imaging of middle cerebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yun Jung; Choi, Byung Se; Jung, Cheol Kyu; Yoon, Yeon Hong; Sunwoo, Leonard; Kim, Jae Hyoung; Bae, Hee Joon [Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2017-11-15

    To evaluate the utility of high-resolution vessel wall imaging (HR-VWI) of middle cerebral artery (MCA), and to compare HR-VWI findings between striatocapsular infarction (SC-I) and lenticulostriate infarction (LS-I). This retrospective study was approved by the Institutional Review Board, and informed consent was waived. From July 2009 to February 2012, 145 consecutive patients with deep subcortical infarctions (SC-I, n = 81; LS-I, n = 64) who underwent HR-VWI were included in this study. The degree of MCA stenosis and the characteristics of MCA plaque (presence, eccentricity, location, extent, T2-high signal intensity [T2-HSI], and plaque enhancement) were analyzed, and compared between SC-I and LS-I, using Fisher's exact test. Stenosis was more severe in SC-I than in LS-I (p = 0.040). MCA plaque was more frequent in SC-I than in LS-I (p = 0.028), having larger plaque extent (p = 0.001), more T2-HSI (p = 0.001), and more plaque enhancement (p = 0.002). The eccentricity and location of the plaque showed no significant difference between the two groups.Both SC-I and LS-I have similar HR-VWI findings of the MCA plaque, but SC-I had more frequent, larger plaques with greater T2-HSI and enhancement. This suggests that HR-VWI may have a promising role in assisting the differentiation of underlying pathophysiological mechanism between SC-I and LS-I.

  20. Follow-up Study of ITER Safety Analysis : Large In-vessel First Wall Pipe Break with Wet Confinement Bypass

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Bo; Bang, In Cheol [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-10-15

    Previous researches have been analyzed risk assessments of fusion reactors that are dangerous in the severe accidents where the radioactive material released from confinement building to the environment. To simulate the severe accidents in ITER, a number of thermal hydraulics simulation codes were used. Before construction of the fusion reactor, to obtain ITER license about safety issue, MELCOR is chosen as one of the several codes to be used to perform ITER safety analyses. Qualification of the simulation code is to simulate the cooling system in ITER, the transport of radionuclides during design basis accidents (DBAs) including beyond design basis accidents (BDBAs). MELCOR is fully integrated code that models the accidents in Light Water Reactor (LWR). To analyze the accidents in ITER, MELCOR 1.8.2 version is modified. In the nuclear fusion system, the amount of released radioactive material is criteria for safety permission. Tritium (or tritiated water: HTO) and radioactive dust aerosol are the source of radioactive leakage. In the Generic Site Safety Report (GSSR) for the ITER plant, Table I lists the release guidelines for tritium and activation products for normal operation, incidents and accidents. Several accident analyses have been studied to know how much radioactive material could be released from the severe accidents. In the present work, The MELCOR input deck of large First Wall (FW) coolant leak (pipe break) is used to study and radioactive material leakage thorough bypass accident are studied to follow up the ITER safety analysis. In this research, follow-up study of the in-vessel inboard/inboard-outboard FW pipe break was analyzed to investigate the amount of leakage of radioactive aerosol. All of the accident cases released the lower amount of radioactive aerosol compared to the IAEA guide lines. In addition, the OBB pipe break made lower HTO aerosol leakage because of condensation of HTO and adsorption between coolant and aerosol.

  1. CMR of microvascular obstruction and hemorrhage in myocardial infarction

    Directory of Open Access Journals (Sweden)

    Wu Katherine C

    2012-09-01

    Full Text Available Abstract Microvascular obstruction (MO or no-reflow phenomenon is an established complication of coronary reperfusion therapy for acute myocardial infarction. It is increasingly recognized as a poor prognostic indicator and marker of subsequent adverse LV remodeling. Although MO can be assessed using various imaging modalities including electrocardiography, myocardial contrast echocardiography, nuclear scintigraphy, and coronary angiography, evaluation by cardiovascular magnetic resonance (CMR is particularly useful in enhancing its detection, diagnosis, and quantification, as well as following its subsequent effects on infarct evolution and healing. MO assessment has become a routine component of the CMR evaluation of acute myocardial infarction and will increasingly play a role in clinical trials of adjunctive reperfusion agents and strategies. This review will summarize the pathophysiology of MO, current CMR approaches to diagnosis, clinical implications, and future directions needed for improving our understanding of this common clinical problem.

  2. Crystallization and preliminary X-ray diffraction analysis of the Cmr2–Cmr3 subcomplex in the CRISPR–Cas RNA-silencing effector complex

    Energy Technology Data Exchange (ETDEWEB)

    Osawa, Takuo; Inanaga, Hideko; Numata, Tomoyuki [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba-shi, Ibaraki 305-8566 (Japan)

    2013-04-30

    The Cmr2–Cmr3 subcomplex from P. furiosus was co-crystallized with 3′-AMP. X-ray diffraction data for the crystals were collected to 2.6 Å resolution using a synchrotron-radiation source. Clustered, regularly interspaced, short palindromic repeat (CRISPR) loci, found in prokaryotes, are transcribed to produce CRISPR RNAs (crRNAs). The Cmr proteins (Cmr1–6) and crRNA form a ribonucleoprotein complex that degrades target RNAs derived from invading genetic elements. Cmr2dHD, a Cmr2 variant lacking the N-terminal putative HD nuclease domain, and Cmr3 were co-expressed in Escherichia coli cells and co-purified as a complex. The Cmr2dHD–Cmr3 complex was co-crystallized with 3′-AMP by the vapour-diffusion method. The crystals diffracted to 2.6 Å resolution using synchrotron radiation at the Photon Factory. The crystals belonged to the orthorhombic space group I222, with unit-cell parameters a = 103.9, b = 136.7, c = 192.0 Å. The asymmetric unit of the crystals is expected to contain one Cmr2dHD–Cmr3 complex with a Matthews coefficient of 3.0 Å{sup 3} Da{sup −1} and a solvent content of 59%.

  3. Crystallization and preliminary X-ray diffraction analysis of the Cmr2–Cmr3 subcomplex in the CRISPR–Cas RNA-silencing effector complex

    International Nuclear Information System (INIS)

    Osawa, Takuo; Inanaga, Hideko; Numata, Tomoyuki

    2013-01-01

    The Cmr2–Cmr3 subcomplex from P. furiosus was co-crystallized with 3′-AMP. X-ray diffraction data for the crystals were collected to 2.6 Å resolution using a synchrotron-radiation source. Clustered, regularly interspaced, short palindromic repeat (CRISPR) loci, found in prokaryotes, are transcribed to produce CRISPR RNAs (crRNAs). The Cmr proteins (Cmr1–6) and crRNA form a ribonucleoprotein complex that degrades target RNAs derived from invading genetic elements. Cmr2dHD, a Cmr2 variant lacking the N-terminal putative HD nuclease domain, and Cmr3 were co-expressed in Escherichia coli cells and co-purified as a complex. The Cmr2dHD–Cmr3 complex was co-crystallized with 3′-AMP by the vapour-diffusion method. The crystals diffracted to 2.6 Å resolution using synchrotron radiation at the Photon Factory. The crystals belonged to the orthorhombic space group I222, with unit-cell parameters a = 103.9, b = 136.7, c = 192.0 Å. The asymmetric unit of the crystals is expected to contain one Cmr2dHD–Cmr3 complex with a Matthews coefficient of 3.0 Å 3 Da −1 and a solvent content of 59%

  4. The Possibilities of Installing Electronic CMR Waybill in Road Transport Sector

    Directory of Open Access Journals (Sweden)

    Arvydas Baublys

    2016-02-01

    Full Text Available In the article opportunities of changing paper CMR waybill into electronic are analysed, whereas the paper CMR waybill does not guarantee operational information exchange between participants of logistics chain components in road transport. Due to this reason use ofelectronic CMR waybill becomes more and more important. According to researches done by article authors, the article submitted the limitations of paper CMR waybill, benefits of electronic CMR waybill, concept model of implementing electronic CMR waybill and application possibilities of supply chain components.

  5. Heat-Induced, Pressure-Induced and Centrifugal-Force-Induced Exact Axisymmetric Thermo-Mechanical Analyses in a Thick-Walled Spherical Vessel, an Infinite Cylindrical Vessel, and a Uniform Disk Made of an Isotropic and Homogeneous Material

    Directory of Open Access Journals (Sweden)

    Vebil Yıldırım

    2017-07-01

    Full Text Available Heat-induced, pressure-induced, and centrifugal force-induced axisymmetric exact deformation and stresses in a thick-walled spherical vessel, a cylindrical vessel, and a uniform disk are all determined analytically at a specified constant surface temperature and at a constant angular velocity. The inner and outer pressures are both included in the formulation of annular structures made of an isotropic and homogeneous linear elastic material. Governing equations in the form of Euler-Cauchy differential equation with constant coefficients are solved and results are presented in compact forms. For disks, three different boundary conditions are taken into account to consider mechanical engineering applications. The present study is also peppered with numerical results in graphical forms.

  6. Should these potential CMR substances have been registered under REACH?

    DEFF Research Database (Denmark)

    Wedebye, Eva Bay; Nikolov, Nikolai Georgiev; Dybdahl, Marianne

    2013-01-01

    (Q)SAR models were applied to screen around 68,000 REACH pre-registered substances for CMR properties (carcinogenic, mutagenic or toxic to reproduction). Predictions from 14 relevant models were combined to reach overall calls for C, M and R. Combining predictions may reduce “noise” and increase...

  7. Comparison of monaural (CMR) and binaural (BMLD) masking release

    NARCIS (Netherlands)

    Par, van de S.L.J.D.E.; Kohlrausch, A.G.

    1998-01-01

    Release of masking for a sinusoidal signal of 5 kHz masked by a 25-Hz-wide noise band centered around 5 kHz was measured. The masking release was provided by a second noise band that was comodulated with the on-frequency masker band. For CMR configurations the second noise band was centered at 3 kHz

  8. Chemical and Metallurgy Research (CMR) Sample Tracking System Design Document

    International Nuclear Information System (INIS)

    Bargelski, C. J.; Berrett, D. E.

    1998-01-01

    The purpose of this document is to describe the system architecture of the Chemical and Metallurgy Research (CMR) Sample Tracking System at Los Alamos National Laboratory. During the course of the document observations are made concerning the objectives, constraints and limitations, technical approaches, and the technical deliverables

  9. CMR assessment after a transapical-transcatheter aortic valve implantation

    International Nuclear Information System (INIS)

    Biere, Loïc; Pinaud, Frédéric; Delépine, Stéphane; Grall, Sylvain; Viot, Nathalie; Mateus, Victor; Rouleau, Frédéric; Corbeau, Jean-Jacques; Prunier, Fabrice

    2014-01-01

    Aims: To describe the time course of myocardial scarring after transapical-transcatheter aortic valve implantation (TA-TAVI) with the Edwards SAPIEN XT™ and the Edwards SAPIEN™ prosthesis in a 3-month follow-up study using cardiac magnetic resonance imaging (CMR). Methods: In 20 TA-TAVI patients, CMR was performed at discharge and 3 months (3M). Cine-MRI was used for left ventricular (LV) functional assessment, and late gadolinium enhancement (LGE) imaging was employed for detecting the presence of myocardial scarring. Special attention was given to any artifacts caused by the prosthesis, which were consequently defined using a three-grade artifact scale. Results: We systematically reported the presence of small LGE hyperintensity relating to the apical segment, with no variation found between discharge and 3 M (2.8 ± 1.6 g vs. 2.35 ± 1.1 g). LV ejection fraction, end-diastolic, and end-systolic volumes did not significantly vary. A small area of apical akinesia was observed, with no improvement at follow-up. Whereas the Edwards SAPIEN XT™ prosthesis and the Edwards SAPIEN™ prosthesis are both constituted by metallic stenting structure, the Edwards SAPIEN™ was responsible for a larger signal void, thus potentially limiting the diagnostic performance of CMR. Conclusions: CMR may be performed safely in the context of TA-TAVI. The presence of a very small apical infarction correlating with focal akinesia was observed. As expected, the Edwards SAPIEN XT™ prosthesis was shown to be particularly suitable for CMR assessment

  10. Dilated thin-walled blood and lymphatic vessels in human endometrium: a potential role for VEGF-D in progestin-induced break-through bleeding.

    Directory of Open Access Journals (Sweden)

    Jacqueline F Donoghue

    Full Text Available Progestins provide safe, effective and cheap options for contraception as well as the treatment of a variety of gynaecological disorders. Episodes of irregular endometrial bleeding or breakthrough bleeding (BTB are a major unwanted side effect of progestin treatment, such that BTB is the leading cause for discontinued use of an otherwise effective and popular medication. The cellular mechanisms leading to BTB are poorly understood. In this study, we make the novel finding that the large, dilated, thin walled vessels characteristic of human progestin-treated endometrium include both blood and lymphatic vessels. Increased blood and lymphatic vessel diameter are features of VEGF-D action in other tissues and we show by immunolocalisation and Western blotting that stromal cell decidualisation results in a significant increase in VEGF-D protein production, particularly of the proteolytically processed 21 kD form. Using a NOD/scid mouse model with xenografted human endometrium we were able to show that progestin treatment causes decidualisation, VEGF-D production and endometrial vessel dilation. Our results lead to a novel hypothesis to explain BTB, with stromal cell decidualisation rather than progestin treatment per se being the proposed causative event, and VEGF-D being the proposed effector agent.

  11. Development of an application-oriented multi-frequency eddy current procedure for the outer reactor vessel- and store vessel wall of the SNR-300

    International Nuclear Information System (INIS)

    Hoeft, E.

    1991-08-01

    The following companies participated in the development of the application oriented multi-frequency eddy current procedure for the outer reactor vessel- and store vesselwall of the SNR-300: Interatom GmbH (coordinator), MAN-Energie GmbH (ME, subcontractor), Fraunhofer Institut IzfP, own promotion project). The precisely defined work packages of the participating companies Interatom and IzfP were supported by the Federal Minister for Research and Technology in separate promotion project. The present report comprises the work performed at Interatom and ME for developing the manipulator and the subsystems. The development aim was reached largely. Manufactoring of the manipulator with all necessary peripherical equipments was finished and accepted in partial function tests at the manufacturer. Tests at the Interatom teststand however with the fully mounted systems at ambient- and reactor temperature could not be done within the appropriated timeschedule and finance frame. (orig.) [de

  12. CMR diagnosis of coronary graft fistula

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2014-01-01

    Full Text Available The patient is a 54-year old man with a previous history of cerebral aqueduct stenosis and hydrocephalus resulting in malignant hypertension who had surgery for permanent ventriculo-peritoneal shunt. At age 41, he had coronary artery bypass graft (CABG surgery with the right internal mammary artery anastomosed to the posterior descending artery and a saphenous vein graft to the first obtuse marginal branch. The patient was recently admitted with pneumonia that rapidly deteriorated and he went in respiratory failure requiring mechanical ventilation. A thoracic CT investigation showed massive bilateral pulmonary infiltrates, pulmonary artery embolism and a large vein graft aneurysm with a maximal diameter of 40 mm (Figure 1 A-B. The management course was complicated with prolonged respiratory failure, persistent infection, despite negative cultures and extended hospital stay. After 50 days of slow recovery the patient was discharged with a need for home oxygen therapy. Ten days later, he was re-admitted with chest pain requiring admission to the coronary care unit where severe pulmonary hypertension was diagnosed with Doppler echocardiography. Troponin-T was mildly elevated, 1,3 ug/L (ref <0,01, CRP was 50 mg/L and chest X-ray showed bilateral lung infiltrates and wide pulmonary vessels. At this point a systo-diastolic murmur was heard at the left lower sternal edge. With a view of potential coronary reintervention and to evaluate the pulmonary hypertension, a coronary angiogram and a pulmonary artery cathetherisation were performed. This showed a new stenosis in the left anterior descending coronary artery and the pulmonary catheterisation showed a “step-up” in oxygen saturation in the pulmonary artery, suggesting a left-to-right shunt. The vein graft aneurysm did not contribute to the coronary circulation. A cardiovascular magnetic resonance scan revealed a communication between the vein graft aneurysm and the left branch pulmonary artery

  13. Importance of CMR within the Task Force Criteria for the diagnosis of ARVC in children and adolescents.

    Science.gov (United States)

    Etoom, Yousef; Govindapillai, Sindu; Hamilton, Robert; Manlhiot, Cedric; Yoo, Shi-Joon; Farhan, Maryam; Sarikouch, Samir; Peters, Brigitte; McCrindle, Brian W; Grosse-Wortmann, Lars

    2015-03-17

    Cardiac magnetic resonance (CMR) is a component of the revised Task Force Criteria (rTFC) for the diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC). However, its diagnostic value in a pediatric population is unknown. This study examined the contribution of CMR to diagnosing ARVC using the rTFC in a pediatric population. Clinical CMR studies of 142 pediatric patients evaluated for ARVC between 2005 and 2009 were reviewed. Patients were categorized into "definitive," "borderline," "possible," or "no" ARVC diagnostic groups based on the rTFC. The extent to which each element of the rTFC contributed to diagnosing ARVC was determined using a c-statistics model. A total of 23 (16%), 32 (23%), 37 (26%), and 50 (35%) patients had definite, borderline, possible, and no ARVC, respectively, applying the rTFC. The prevalence of regional wall motion abnormalities in these groups was 83%, 53%, 22%, and 16%, respectively (p important contributors to a diagnosis of ARVC in children, using the rTFC. Fatty infiltration and myocardial fibrosis provide limited value in children and adolescents. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. High-resolution 3D coronary vessel wall imaging with near 100% respiratory efficiency using epicardial fat tracking: reproducibility and comparison with standard methods.

    Science.gov (United States)

    Scott, Andrew D; Keegan, Jennifer; Firmin, David N

    2011-01-01

    To quantitatively assess the performance and reproducibility of 3D spiral coronary artery wall imaging with beat-to-beat respiratory-motion-correction (B2B-RMC) compared to navigator gated 2D spiral and turbo-spin-echo (TSE) acquisitions. High-resolution (0.7 × 0.7 mm) cross-sectional right coronary wall acquisitions were performed in 10 subjects using four techniques (B2B-RMC 3D spiral with alternate (2RR) and single (1RR) R-wave gating, navigator-gated 2D spiral (2RR) and navigator-gated 2D TSE (2RR)) on two occasions. Wall thickness measurements were compared with repeated measures analysis of variance (ANOVA). Reproducibility was assessed with the intraclass correlation coefficient (ICC). In all, 91% (73/80) of acquisitions were successful (failures: four TSE, two 3D spiral (1RR) and one 3D spiral (2RR)). Respiratory efficiency of the B2B-RMC was less variable and substantially higher than for navigator gating (99.6 ± 1.2% vs. 39.0 ± 7.5%, P B2B-RMC permits coronary vessel wall assessment over multiple thin contiguous slices in a clinically feasible duration. Excellent reproducibility of the technique potentially enables studies of disease progression/regression. Copyright © 2010 Wiley-Liss, Inc.

  15. PET-CMR in heart failure - synergistic or redundant imaging?

    Science.gov (United States)

    Quail, Michael A; Sinusas, Albert J

    2017-07-01

    Imaging in heart failure (HF) provides data for diagnosis, prognosis and disease monitoring. Both MRI and nuclear imaging techniques have been successfully used for this purpose in HF. Positron Emission Tomography-Cardiac Magnetic Resonance (PET-CMR) is an example of a new multimodality diagnostic imaging technique with potential applications in HF. The threshold for adopting a new diagnostic tool to clinical practice must necessarily be high, lest they exacerbate costs without improving care. New modalities must demonstrate clinical superiority, or at least equivalence, combined with another important advantage, such as lower cost or improved patient safety. The purpose of this review is to outline the current status of multimodality PET-CMR with regard to HF applications, and determine whether the clinical utility of this new technology justifies the cost.

  16. Myocardial Blood Volume Is Associated with Myocardial Oxygen Consumption: An Experimental Study with CMR in a Canine Model

    Science.gov (United States)

    McCommis, Kyle S.; Zhang, Haosen; Goldstein, Thomas A.; Misselwitz, Bernd; Abendschein, Dana R.; Gropler, Robert J.; Zheng, Jie

    2009-01-01

    OBJECTIVES To evaluate the feasibility of cardiovascular MR (CMR) to determine regional myocardial perfusion and O2 metabolism, and assess the role of myocardial blood volume (MBV) on oxygen supply. BACKGROUND Coronary artery disease presents as an imbalance of myocardial oxygen supply and demand. We have developed relevant CMR methods to determine the relationship of myocardial blood flow (MBF) and MBV to oxygen consumption (MVO2) during pharmacologic hyperemia. METHODS Twenty-one mongrel dogs were studied with varying stenosis severities imposed on the proximal left anterior descending (LAD) coronary artery. MBF and MBV were determined by CMR first-pass perfusion, while the oxygen extraction fraction (OEF) and MVO2 were determined by the myocardial Blood-Oxygen-Level-Dependent (BOLD) effect and Fick’s law, respectively. MR imaging was performed at rest, and during either dipyridamole-induced vasodilation or dobutamine-induced hyperemia. Regional differences in myocardial perfusion and oxygenation were then evaluated. RESULTS Dipyridamole and dobutamine both led to 145–200% increases in MBF and 50–80% increases in MBV in normal perfused myocardium. As expected, MVO2 increased more significantly with dobutamine (~175%) than dipyridamole (~40%). Coronary stenosis resulted in an attenuation of MBF, MBV, and MVO2 in both the LAD-subtended stenosis region and the left circumflex subtended remote region. Liner regression analysis showed that MBV reserve appears to be more correlated with MVO2 reserve during dobutamine stress than MBF reserve, particularly in the stenotic regions. Conversely, MBF reserve appears to be more correlated with MVO2 reserve during dipyridamole, although neither of these differences was significant. CONCLUSIONS Noninvasive evaluation of both myocardial perfusion and oxygenation by CMR facilitates direct monitoring of regional myocardial ischemia and provides a valuable tool for better understanding microvascular pathophysiology. These

  17. Remodeling after acute myocardial infarction: mapping ventricular dilatation using three dimensional CMR image registration

    Directory of Open Access Journals (Sweden)

    O’Regan Declan P

    2012-06-01

    Full Text Available Abstract Background Progressive heart failure due to remodeling is a major cause of morbidity and mortality following myocardial infarction. Conventional clinical imaging measures global volume changes, and currently there is no means of assessing regional myocardial dilatation in relation to ischemic burden. Here we use 3D co-registration of Cardiovascular Magnetic Resonance (CMR images to assess the long-term effects of ischemia-reperfusion injury on left ventricular structure after acute ST-elevation myocardial infarction (STEMI. Methods Forty six patients (age range 33–77 years underwent CMR imaging within 7 days following primary percutaneous coronary intervention (PPCI for acute STEMI with follow-up at one year. Functional cine imaging and Late Gadolinium Enhancement (LGE were segmented and co-registered. Local left ventricular wall dilatation was assessed by using intensity-based similarities to track the structural changes in the heart between baseline and follow-up. Results are expressed as means, standard errors and 95% confidence interval (CI of the difference. Results Local left ventricular remodeling within infarcted myocardium was greater than in non-infarcted myocardium (1.6% ± 1.0 vs 0.3% ± 0.9, 95% CI: -2.4% – -0.2%, P = 0.02. One-way ANOVA revealed that transmural infarct thickness had a significant effect on the degree of local remodeling at one year (P 20% (4.8% ± 1.4 vs −0.15% ± 1.2, 95% CI: -8.9% – -0.9%, P = 0.017. Conclusions The severity of ischemic injury has a significant effect on local ventricular wall remodeling with only modest dilatation observed within non-ischemic myocardium. Limitation of chronic remodeling may therefore depend on therapies directed at modulating ischemia-reperfusion injury. CMR co-registration has potential for assessing dynamic changes in ventricular structure in relation to therapeutic interventions.

  18. An objective method to optimize the MR sequence set for plaque classification in carotid vessel wall images using automated image segmentation.

    Directory of Open Access Journals (Sweden)

    Ronald van 't Klooster

    Full Text Available A typical MR imaging protocol to study the status of atherosclerosis in the carotid artery consists of the application of multiple MR sequences. Since scanner time is limited, a balance has to be reached between the duration of the applied MR protocol and the quantity and quality of the resulting images which are needed to assess the disease. In this study an objective method to optimize the MR sequence set for classification of soft plaque in vessel wall images of the carotid artery using automated image segmentation was developed. The automated method employs statistical pattern recognition techniques and was developed based on an extensive set of MR contrast weightings and corresponding manual segmentations of the vessel wall and soft plaque components, which were validated by histological sections. Evaluation of the results from nine contrast weightings showed the tradeoff between scan duration and automated image segmentation performance. For our dataset the best segmentation performance was achieved by selecting five contrast weightings. Similar performance was achieved with a set of three contrast weightings, which resulted in a reduction of scan time by more than 60%. The presented approach can help others to optimize MR imaging protocols by investigating the tradeoff between scan duration and automated image segmentation performance possibly leading to shorter scanning times and better image interpretation. This approach can potentially also be applied to other research fields focusing on different diseases and anatomical regions.

  19. Inner and outer coronary vessel wall segmentation from CCTA using an active contour model with machine learning-based 3D voxel context-aware image force

    Science.gov (United States)

    Sivalingam, Udhayaraj; Wels, Michael; Rempfler, Markus; Grosskopf, Stefan; Suehling, Michael; Menze, Bjoern H.

    2016-03-01

    In this paper, we present a fully automated approach to coronary vessel segmentation, which involves calcification or soft plaque delineation in addition to accurate lumen delineation, from 3D Cardiac Computed Tomography Angiography data. Adequately virtualizing the coronary lumen plays a crucial role for simulating blood ow by means of fluid dynamics while additionally identifying the outer vessel wall in the case of arteriosclerosis is a prerequisite for further plaque compartment analysis. Our method is a hybrid approach complementing Active Contour Model-based segmentation with an external image force that relies on a Random Forest Regression model generated off-line. The regression model provides a strong estimate of the distance to the true vessel surface for every surface candidate point taking into account 3D wavelet-encoded contextual image features, which are aligned with the current surface hypothesis. The associated external image force is integrated in the objective function of the active contour model, such that the overall segmentation approach benefits from the advantages associated with snakes and from the ones associated with machine learning-based regression alike. This yields an integrated approach achieving competitive results on a publicly available benchmark data collection (Rotterdam segmentation challenge).

  20. Vascular wall-resident CD44+ multipotent stem cells give rise to pericytes and smooth muscle cells and contribute to new vessel maturation.

    Directory of Open Access Journals (Sweden)

    Diana Klein

    Full Text Available Here, we identify CD44(+CD90(+CD73(+CD34(-CD45(- cells within the adult human arterial adventitia with properties of multipotency which were named vascular wall-resident multipotent stem cells (VW-MPSCs. VW-MPSCs exhibit typical mesenchymal stem cell characteristics including cell surface markers in immunostaining and flow cytometric analyses, and differentiation into adipocytes, chondrocytes and osteocytes under culture conditions. Particularly, TGFß1 stimulation up-regulates smooth muscle cell markers in VW-MPSCs. Using fluorescent cell labelling and co-localisation studies we show that VW-MPSCs differentiate to pericytes/smooth muscle cells which cover the wall of newly formed endothelial capillary-like structures in vitro. Co-implantation of EGFP-labelled VW-MPSCs and human umbilical vein endothelial cells into SCID mice subcutaneously via Matrigel results in new vessels formation which were covered by pericyte- or smooth muscle-like cells generated from implanted VW-MPSCs. Our results suggest that VW-MPSCs are of relevance for vascular morphogenesis, repair and self-renewal of vascular wall cells and for local capacity of neovascularization in disease processes.

  1. Effects of Simulated Microgravity on Otolith Growth of Larval Zebrafish using a Rotating-Wall Vessel: Appropriate Rotation Speed and Fish Developmental Stage

    Science.gov (United States)

    Li, Xiaoyan; Anken, Ralf; Liu, Liyue; Wang, Gaohong; Liu, Yongding

    2017-02-01

    Stimulus dependence is a general feature of developing animal sensory systems. In this respect, it has extensively been shown earlier that fish inner ear otoliths can act as test masses as their growth is strongly affected by altered gravity such as hypergravity obtained using centrifuges, by (real) microgravity achieved during spaceflight or by simulated microgravity using a ground-based facility. Since flight opportunities are scarce, ground-based simulators of microgravity, using a wide variety of physical principles, have been developed to overcome this shortcoming. Not all of them, however, are equally well suited to provide functional weightlessness from the perspective of the biosystem under evaluation. Therefore, the range of applicability of a particular simulator has to be extensively tested. Earlier, we have shown that a Rotating-Wall Vessel (RWV) can be used to provide simulated microgravity for developing Zebrafish regarding the effect of rotation on otolith development. In the present study, we wanted to find the most effective speed of rotation and identify the appropriate developmental stage of Zebrafish, where effects are the largest, in order to provide a methodological basis for future in-depth analyses dedicated to the physiological processes underlying otolith growth at altered gravity. Last not least, we compared data on the effect of simulated microgravity on the size versus the weight of otoliths, since the size usually is measured in related studies due to convenience, but the weight more accurately approximates the physical capacity of an otolith. Maintaining embryos at 10 hours post fertilization for three days in the RWV, we found that 15 revolutions per minute (rpm) yielded the strongest effects on otolith growth. Maintenance of Zebrafish staged at 10 hpf, 1 day post fertilization (dpf), 4 dpf, 7 dpf and 14 dpf for three days at 15 rpm resulted in the most prominent effects in 7 dpf larvae. Weighing versus measuring the size of otoliths

  2. Formation of three-dimensional cell/polymer constructs for bone tissue engineering in a spinner flask and a rotating wall vessel bioreactor

    Science.gov (United States)

    Sikavitsas, Vassilios I.; Bancroft, Gregory N.; Mikos, Antonios G.; McIntire, L. V. (Principal Investigator)

    2002-01-01

    The aim of this study is to investigate the effect of the cell culture conditions of three-dimensional polymer scaffolds seeded with rat marrow stromal cells (MSCs) cultured in different bioreactors concerning the ability of these cells to proliferate, differentiate towards the osteoblastic lineage, and generate mineralized extracellular matrix. MSCs harvested from male Sprague-Dawley rats were culture expanded, seeded on three-dimensional porous 75:25 poly(D,L-lactic-co-glycolic acid) biodegradable scaffolds, and cultured for 21 days under static conditions or in two model bioreactors (a spinner flask and a rotating wall vessel) that enhance mixing of the media and provide better nutrient transport to the seeded cells. The spinner flask culture demonstrated a 60% enhanced proliferation at the end of the first week when compared to static culture. On day 14, all cell/polymer constructs exhibited their maximum alkaline phosphatase activity (AP). Cell/polymer constructs cultured in the spinner flask had 2.4 times higher AP activity than constructs cultured under static conditions on day 14. The total osteocalcin (OC) secretion in the spinner flask culture was 3.5 times higher than the static culture, with a peak OC secretion occurring on day 18. No considerable AP activity and OC secretion were detected in the rotating wall vessel culture throughout the 21-day culture period. The spinner flask culture had the highest calcium content at day 14. On day 21, the calcium deposition in the spinner flask culture was 6.6 times higher than the static cultured constructs and over 30 times higher than the rotating wall vessel culture. Histological sections showed concentration of cells and mineralization at the exterior of the foams at day 21. This phenomenon may arise from the potential existence of nutrient concentration gradients at the interior of the scaffolds. The better mixing provided in the spinner flask, external to the outer surface of the scaffolds, may explain the

  3. Morphological changes of cerebral vessels and expression patterns of MMP-2 and MMP-9 on cerebrovascular wall of alcoholic rats.

    Science.gov (United States)

    Qi, Qian; Liu, Xia; Zhang, Guozhong; He, Wenjing; Ma, Rufei; Cong, Bin; Li, Yingmin

    2014-01-01

    Alcohol abuse increases the incidence of cerebral accidents, which correlates with cerebrovascular structural changes. The present study was designed to observe the cerebrovascular remodeling of drinking rats with light microscopy and transmission electron microscopy (TEM). Short-term alcohol administration induced apparent amplification of perivascular spaces around small vessels in brain tissue, while long-term administration caused pathological changes of basilar arteries (BAs), including endothelial exfoliation, inner elastic lamina (IEL) fragmentation and thickening of tunica media and adventitia. In addition, the relationship between cerebrovascular remodeling and MMP-2 and MMP-9 synthesized by endothelial cells and vascular smooth muscle cells was explored by immunohistochemistry. The two protein expression in cerebral vessels changed dynamically, peaking at 1-2 weeks after treatment, and decreasing as treatment continued. These results suggest that MMP-2 and MMP-9 may play a significant role in blood-brain barrier disruption after alcohol abuse. But the chronic changes of cerebral arteries resulted from drinking are not coincident with time course of MMP-2 and MMP-9 expression in situ.

  4. In-vessel calibration of the imaging diagnostics for the real-time protection of the JET ITER-like wall

    Energy Technology Data Exchange (ETDEWEB)

    Huber, V., E-mail: V.Huber@fz-juelich.de [Forschungszentrum Jülich GmbH, Supercomputing Centre, 52425 Jülich (Germany); Huber, A.; Mertens, Ph.; Sergienko, G. [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung—Plasmaphysik, Partner of the Trilateral Euregio Cluster (TEC), 52425 Jülich (Germany); Kinna, D.; Balboa, I.; Collins, S.; Conway, N.; Maggi, C. F.; Matthews, G. F.; Meigs, A. G.; Price, M.; Silburn, S.; Zastrow, K.-D. [CCFE, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Drewelow, P. [MPI für Plasmaphysik, Greifswald (Germany); Wynn, A. [York Plasma Institute, University of York, Heslington, York YO10 5DD (United Kingdom)

    2016-11-15

    The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.

  5. Impact of scaffold micro and macro architecture on Schwann cell proliferation under dynamic conditions in a rotating wall vessel bioreactor

    International Nuclear Information System (INIS)

    Valmikinathan, Chandra M.; Hoffman, John; Yu, Xiaojun

    2011-01-01

    Over the last decade tissue engineering has emerged as a powerful alternative to regenerate lost tissues owing to trauma or tumor. Evidence shows that Schwann cell containing scaffolds have improved performance in vivo as compared to scaffolds that depend on cellularization post implantation. However, owing to limited supply of cells from the patients themselves, several approaches have been taken to enhance cell proliferation rates to produce complete and uniform cellularization of scaffolds. The most common approach is the application of a bioreactor to enhance cell proliferation rate and therefore reduce the time needed to obtain sufficiently significant number of glial cells, prior to implantation. In this study, we show the application of a rotating wall bioreactor system for studying Schwann cell proliferation on nanofibrous spiral shaped scaffolds, prepared by solvent casting and salt leaching techniques. The scaffolds were fabricated from polycaprolactone (PCL), which has ideal mechanical properties and upon degradation does not produce acidic byproducts. The spiral scaffolds were coated with aligned or random nanofibers, produced by electrospinning, to provide a substrate that mimics the native extracellular matrix and the essential contact guidance cues. At the 4 day time point, an enhanced rate of cell proliferation was observed on the open structured nanofibrous spiral scaffolds in a rotating wall bioreactor, as compared to static culture conditions. However, the cell proliferation rate on the other contemporary scaffolds architectures such as the tubular and cylindrical scaffolds show reduced cell proliferation in the bioreactor as compared to static conditions, at the same time point. Moreover, the rotating wall bioreactor does not alter the orientation or the phenotype of the Schwann cells on the aligned nanofiber containing scaffolds, wherein, the cells remain aligned along the length of the scaffolds. Therefore, these open structured spiral

  6. Comparison of CT and CMR for detection and quantification of carotid artery calcification

    DEFF Research Database (Denmark)

    Mujaj, Blerim; Lorza, Andrés M. Arias; van Engelen, Arna

    2017-01-01

    interscan interval: 4.9 ± 1.2 years). We investigated the correlation between the amount of calcification measured on CT and CMR using Spearman's correlation coefficient, Bland-Altman plots, and linear regression. In addition, using logistic regression modeling, we assessed the association of CT and CMR...... larger. Finally, calcification volume assessed with either imaging modality was associated with a history of stroke with similar effect estimates (odds ratio (OR) per 1-SD increase in calcification volume: 1.52 (95% CI:1.00;2.30) for CT, and 1.47 (95% CI:1.01;2.14) for CMR. CONCLUSION: CT based and CMR...

  7. Return to normal of sup(99m)Tc-plasmin test after deep venous thrombosis and its relationship to vessel wall fibrinolysis

    Energy Technology Data Exchange (ETDEWEB)

    Edenbrandt, C.M.; Hedner, U.; Tengborn, L.; Nilsson, J.; Ohlin, P.

    1986-08-01

    Fourteen patients with deep venous thrombosis (DVT) and a positive sup(99m)Tc-plasmin test were followed up to determine how soon a negative test was obtained. Localization and extension of the thrombi were determined by phlebography. Plasminogen activator activity in vein walls and local fibrinolytic activity after venous occlusion were measured in order to find out what the prerequisites for impaired thrombolysis are. The time required to obtain a negative sup(99m)Tc-plasmin test showed considerable variation, ranging from less than 1 week to more than 6 months. The sup(99m)Tc-plasmin test had returned to normal in 64% of the patients after 6 months. No relationship was found between vessel wall fibrinolysis and time to normalization. Instead, we found an association between the time to normalization of the sup(99m)Tc-plasmin test and the size of the thrombus, according to phlebography, as well as between the time to normalization of the sup(99m)Tc-plasmin test and the extension of leg points with a positive sup(99m)Tc-plasmin test at admission. The finding of abnormal sup(99m)Tc-plasmin test results more than 6 months after acute DVT is of practical importance and warrants caution when evaluating patients with symptoms and signs suggestive of acute recurrent DVT.

  8. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  9. Incremental value of regional wall motion analysis immediately after exercise for the detection of single-vessel coronary artery disease. Study by separate acquisition, dual-isotope ECG-gated single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yoda, Shunichi; Sato, Yuichi; Matsumoto, Naoya; Tani, Shigemasa; Takayama, Tadateru; Uchiyama, Takahisa; Saito, Satoshi

    2005-01-01

    Although the detection of wall motion abnormalities gives incremental value to myocardial perfusion single-photon emission computed tomography (SPECT) in the diagnosis of extensive coronary artery disease (CAD) and high-grade single-vessel CAD, whether or not it is useful in the diagnosis of mild, single-vessel CAD has not been studied previously. Separate acquisition, dual isotope electrocardiogram (ECG)-gated SPECT was performed in 97 patients with a low likelihood of CAD (Group 1) and 46 patients with single-vessel CAD (Group 2). Mild CAD was defined by stenosis of 50-75% (Group 2a, n=22) and moderate to severe CAD was defined by stenosis ≥76% (Group 2b, n=24). Myocardial perfusion and wall motion were graded by a 5 point-scale, 20-segment model. The sensitivity of myocardial perfusion alone was 50% for Group 2a, 83% for Group 2b and 67% for Group 2 as a whole. The overall specificity was 90%. When the wall motion analysis was combined, the sensitivity was increased to 82% in Group 2a and 92% in Group 2b. The ability to detect a wall motion abnormality immediately after exercise gives incremental diagnostic value to myocardial perfusion SPECT in the identification of mild, single-vessel CAD. (author)

  10. Crystallization and preliminary X-ray diffraction analysis of the CRISPR-Cas RNA-silencing Cmr complex.

    Science.gov (United States)

    Osawa, Takuo; Inanaga, Hideko; Numata, Tomoyuki

    2015-06-01

    Clustered regularly interspaced short palindromic repeat (CRISPR)-derived RNA (crRNA) and CRISPR-associated (Cas) proteins constitute a prokaryotic adaptive immune system (CRISPR-Cas system) that targets and degrades invading genetic elements. The type III-B CRISPR-Cas Cmr complex, composed of the six Cas proteins (Cmr1-Cmr6) and a crRNA, captures and cleaves RNA complementary to the crRNA guide sequence. Here, a Cmr1-deficient functional Cmr (CmrΔ1) complex composed of Pyrococcus furiosus Cmr2-Cmr3, Archaeoglobus fulgidus Cmr4-Cmr5-Cmr6 and the 39-mer P. furiosus 7.01-crRNA was prepared. The CmrΔ1 complex was cocrystallized with single-stranded DNA (ssDNA) complementary to the crRNA guide by the vapour-diffusion method. The crystals diffracted to 2.1 Å resolution using synchrotron radiation at the Photon Factory. The crystals belonged to the triclinic space group P1, with unit-cell parameters a = 75.5, b = 76.2, c = 139.2 Å, α = 90.3, β = 104.8, γ = 118.6°. The asymmetric unit of the crystals is expected to contain one CmrΔ1-ssDNA complex, with a Matthews coefficient of 2.03 Å(3) Da(-1) and a solvent content of 39.5%.

  11. Breast arterial calcification and risk of carotid atherosclerosis: Focusing on the preferentially affected layer of the vessel wall

    Energy Technology Data Exchange (ETDEWEB)

    Sedighi, Nahid, E-mail: nsedighi@sina.tums.ac.ir [Department of Radiology, Shariati Hospital, Tehran University of Medical Sciences. North Kargar Ave., Tehran 14114 (Iran, Islamic Republic of); Radmard, Amir Reza, E-mail: radmard@ams.ac.ir [Department of Radiology, Shariati Hospital, Tehran University of Medical Sciences. North Kargar Ave., Tehran 14114 (Iran, Islamic Republic of); Radmehr, Ali, E-mail: radmehr@sina.tums.ac.ir [Department of Radiology, Shariati Hospital, Tehran University of Medical Sciences. North Kargar Ave., Tehran 14114 (Iran, Islamic Republic of); Hashemi, Pari, E-mail: phtums@yahoo.com [Department of Radiology, Shariati Hospital, Tehran University of Medical Sciences. North Kargar Ave., Tehran 14114 (Iran, Islamic Republic of); Hajizadeh, Abdolmahmoud, E-mail: mroomezi@yahoo.com [Department of Radiology, Shariati Hospital, Tehran University of Medical Sciences. North Kargar Ave., Tehran 14114 (Iran, Islamic Republic of); Taheri, Amir Pejman Hashemi, E-mail: hashemip@sina.tums.ac.ir [Department of Radiology, Shariati Hospital, Tehran University of Medical Sciences. North Kargar Ave., Tehran 14114 (Iran, Islamic Republic of)

    2011-08-15

    Objective: To assess the relationship between breast arterial calcification (BAC) detected on screening mammography and atherosclerosis of carotid arteries considering the most likely involved layer of the arterial wall. Materials and methods: A total of 537 consecutive women who underwent screening mammography were enrolled in this study. Seventy-nine subjects having BAC, aged 46-75 years, and 125 age-matched controls from those without BAC were selected for ultrasound examination of carotid arteries assessing intima-media thickness (IMT) and plaque presence. Participants were divided into three groups of risk including, low-risk: IMT < 0.6 mm without plaque, medium-risk: 0.6 mm {<=} IMT {<=} 0.8 mm without plaque and high-risk: IMT > 0.8 mm and/or plaque. Risk factors for atherosclerosis were obtained from medical records for independent effects. Results: BAC was present in 14.7% of mammograms. According to multivariable logistic regression analyses, significant association was identified between the carotid atherosclerosis risk and presence of BAC. Compared to women with IMT < 0.6 mm, those with 0.6 mm {<=} IMT{<=} 0.8 mm and IMT > 0.8 mm had OR (95% CI) of 4.88 (1.47-16.16) and 23.36 (4.54-120.14), respectively. The OR (95% CI) for carotid plaque was 3.13 (1.3-7.57). There was no interaction between IMT category and plaque. Significant associations were also detected with postmenopausal duration (P = 0.02) and hypertension (P = 0.004). Conclusion: The risk of carotid atherosclerosis increases with the presence of BAC. Women with BAC are more likely to have thicker IMT than plaque, which could be attributed to the preferentially similar affected layer of media causing thick IMT rather than plaque.

  12. Breast arterial calcification and risk of carotid atherosclerosis: Focusing on the preferentially affected layer of the vessel wall

    International Nuclear Information System (INIS)

    Sedighi, Nahid; Radmard, Amir Reza; Radmehr, Ali; Hashemi, Pari; Hajizadeh, Abdolmahmoud; Taheri, Amir Pejman Hashemi

    2011-01-01

    Objective: To assess the relationship between breast arterial calcification (BAC) detected on screening mammography and atherosclerosis of carotid arteries considering the most likely involved layer of the arterial wall. Materials and methods: A total of 537 consecutive women who underwent screening mammography were enrolled in this study. Seventy-nine subjects having BAC, aged 46-75 years, and 125 age-matched controls from those without BAC were selected for ultrasound examination of carotid arteries assessing intima-media thickness (IMT) and plaque presence. Participants were divided into three groups of risk including, low-risk: IMT 0.8 mm and/or plaque. Risk factors for atherosclerosis were obtained from medical records for independent effects. Results: BAC was present in 14.7% of mammograms. According to multivariable logistic regression analyses, significant association was identified between the carotid atherosclerosis risk and presence of BAC. Compared to women with IMT 0.8 mm had OR (95% CI) of 4.88 (1.47-16.16) and 23.36 (4.54-120.14), respectively. The OR (95% CI) for carotid plaque was 3.13 (1.3-7.57). There was no interaction between IMT category and plaque. Significant associations were also detected with postmenopausal duration (P = 0.02) and hypertension (P = 0.004). Conclusion: The risk of carotid atherosclerosis increases with the presence of BAC. Women with BAC are more likely to have thicker IMT than plaque, which could be attributed to the preferentially similar affected layer of media causing thick IMT rather than plaque.

  13. Tamoxifen up-regulates catalase production, inhibits vessel wall neutrophil infiltration, and attenuates development of experimental abdominal aortic aneurysms.

    Science.gov (United States)

    Grigoryants, Vladimir; Hannawa, Kevin K; Pearce, Charles G; Sinha, Indranil; Roelofs, Karen J; Ailawadi, Gorav; Deatrick, Kristopher B; Woodrum, Derek T; Cho, Brenda S; Henke, Peter K; Stanley, James C; Eagleton, Matthew J; Upchurch, Gilbert R

    2005-01-01

    controls on day 7 (P = .05). Administration of the direct catalase inhibitor AT to tamoxifen-treated rats partially reversed the aneurysm inhibitory effect of tamoxifen by nearly 30% (P = .02). In contrast, catalase administration inhibited AAA formation by 44% (P = .002). The selective estrogen receptor modulator tamoxifen inhibits the development of AAAs in male rats in association with an up-regulation of catalase and inhibition of aortic wall neutrophil infiltration.

  14. Investigation of radial shear in the wall-base juncture of a 1:4 scale prestressed concrete containment vessel model

    Energy Technology Data Exchange (ETDEWEB)

    Dameron, R.A.; Rashid, Y.R. [ANATECH Corp., San Diego, CA (United States); Luk, V.K.; Hessheimer, M.F. [Sandia National Labs., Albuquerque, NM (United States)

    1998-04-01

    Construction of a prestressed concrete containment vessel (PCCV) model is underway as part of a cooperative containment research program at Sandia National Laboratories. The work is co-sponsored by the Nuclear Power Engineering Corporation (NUPEC) of Japan and US Nuclear Regulatory Commission (NRC). Preliminary analyses of the Sandia 1:4 Scale PCCV Model have determined axisymmetric global behavior and have estimated the potential for failure in several areas, including the wall-base juncture and near penetrations. Though the liner tearing failure mode has been emphasized, the assumption of a liner tearing failure mode is largely based on experience with reinforced concrete containments. For the PCCV, the potential for shear failure at or near the liner tearing pressure may be considerable and requires detailed investigation. This paper examines the behavior of the PCCV in the region most susceptible to a radial shear failure, the wall-basemat juncture region. Prediction of shear failure in concrete structures is a difficult goal, both experimentally and analytically. As a structure begins to deform under an applied system of forces that produce shear, other deformation modes such as bending and tension/compression begin to influence the response. Analytically, difficulties lie in characterizing the decrease in shear stiffness and shear stress and in predicting the associated transfer of stress to reinforcement as cracks become wider and more extensive. This paper examines existing methods for representing concrete shear response and existing criteria for predicting shear failure, and it discusses application of these methods and criteria to the study of the 1:4 scale PCCV.

  15. Investigation of radial shear in the wall-base juncture of a 1:4 scale prestressed concrete containment vessel model

    International Nuclear Information System (INIS)

    Dameron, R.A.; Rashid, Y.R.; Luk, V.K.; Hessheimer, M.F.

    1998-04-01

    Construction of a prestressed concrete containment vessel (PCCV) model is underway as part of a cooperative containment research program at Sandia National Laboratories. The work is co-sponsored by the Nuclear Power Engineering Corporation (NUPEC) of Japan and US Nuclear Regulatory Commission (NRC). Preliminary analyses of the Sandia 1:4 Scale PCCV Model have determined axisymmetric global behavior and have estimated the potential for failure in several areas, including the wall-base juncture and near penetrations. Though the liner tearing failure mode has been emphasized, the assumption of a liner tearing failure mode is largely based on experience with reinforced concrete containments. For the PCCV, the potential for shear failure at or near the liner tearing pressure may be considerable and requires detailed investigation. This paper examines the behavior of the PCCV in the region most susceptible to a radial shear failure, the wall-basemat juncture region. Prediction of shear failure in concrete structures is a difficult goal, both experimentally and analytically. As a structure begins to deform under an applied system of forces that produce shear, other deformation modes such as bending and tension/compression begin to influence the response. Analytically, difficulties lie in characterizing the decrease in shear stiffness and shear stress and in predicting the associated transfer of stress to reinforcement as cracks become wider and more extensive. This paper examines existing methods for representing concrete shear response and existing criteria for predicting shear failure, and it discusses application of these methods and criteria to the study of the 1:4 scale PCCV

  16. Presence of calcium in the vessel walls after end-to-end arterial anastomoses with polydioxanone and polypropylene sutures in growing dogs.

    Science.gov (United States)

    Gersak, B

    1993-10-01

    The presence of calcium in the vessel walls after end-to-end arterial anastomoses performed with polydioxanone and polypropylene interrupted sutures was studied in 140 anastomoses in 35 10-week-old German shepherd dogs. Histologic examination with hematoxylin and eosin, van Gieson, and von Kossa staining techniques was performed after the animals were killed 6 months after the operation. Ketamine hydrochloride was used as an anesthetic agent. At the start of the investigation the dogs weighed 14.5 +/- 2.6 kg (mean +/- standard deviation, n = 35), and after 6 months they weighed 45.3 +/- 3.1 kg (mean +/- standard deviation, n = 35). The diameter of the sutured arteries in the first operation was 2.6 +/- 0.5 mm (mean +/- standard deviation, n = 140). With each dog, both brachial and both femoral arteries were used--one artery for each different type of suture. In different dogs, different arteries were used for the same type of suture. The prevalence of calcifications after 6 months was determined from the numeric density of calcifications with standard stereologic techniques. The sutured and sutureless parts taken from longitudinal sections from each artery were studied, and t test values were calculated as follows: In paired samples, statistically significant differences in numerical density of calcifications were seen between sutured and sutureless arterial parts for both materials (sutureless part versus part with polydioxanone sutures, p 0.05, n = 70) and sutureless parts (p > 0.05, n = 70).

  17. Structure of the Cmr2 Subunit of the CRISPR-Cas RNA Silencing Complex

    Energy Technology Data Exchange (ETDEWEB)

    Cocozaki, Alexis I.; Ramia, Nancy F.; Shao, Yaming; Hale, Caryn R.; Terns, Rebecca M.; Terns, Michael P.; Li, Hong (FSU); (Georgia)

    2012-08-10

    Cmr2 is the largest and an essential subunit of a CRISPR RNA-Cas protein complex (the Cmr complex) that cleaves foreign RNA to protect prokaryotes from invading genetic elements. Cmr2 is thought to be the catalytic subunit of the effector complex because of its N-terminal HD nuclease domain. Here, however, we report that the HD domain of Cmr2 is not required for cleavage by the complex in vitro. The 2.3 {angstrom} crystal structure of Pyrococcus furiosus Cmr2 (lacking the HD domain) reveals two adenylyl cyclase-like and two {alpha}-helical domains. The adenylyl cyclase-like domains are arranged as in homodimeric adenylyl cyclases and bind ADP and divalent metals. However, mutagenesis studies show that the metal- and ADP-coordinating residues of Cmr2 are also not critical for cleavage by the complex. Our findings suggest that another component provides the catalytic function and that the essential role by Cmr2 does not require the identified ADP- or metal-binding or HD domains in vitro.

  18. Varied exposure to carcinogenic, mutagenic, and reprotoxic (CMR) chemicals in occupational settings in France

    Energy Technology Data Exchange (ETDEWEB)

    Havet, Nathalie [Univ. Claude Bernard Lyon 1 (France). Lab. SAF; Penot, Alexis [Lyon Univ. (France). ENS Lyon, GATE-UMR 5824-CNRS; Morelle, Magali; Perrier, Lionel [Lyon Univ. (France). Direction de la Recherche Clinique et de l' Innovation; Charbotel, Barbara [Univ. Claude Bernard Lyon 1 (France). Centre Hospitalier Lyon Sud Service des Maladies Professionnelles; Fervers, Beatrice [Lyon Univ. (France). Dept. Cancer and Environment

    2017-02-15

    To explore varied exposure to carcinogenic, mutagenic, and reprotoxic chemicals (CMR) for French employees. Our study assessed data from the French national cross-sectional survey of occupational risks (SUMER) that was conducted in 2010 in a national representative sample of employees. We selected 28 CMR agents that were classified by the International Agency for Research on Cancer or European Union as being known or presumed to have CMR potential in humans. The association of individual and job characteristics with exposure prevalence, duration, and intensity of the CMR agents during a 1-week period was examined using multilevel logistic regression analysis. Overall, 10.4% of employees in 2010 were exposed to one or more CMR agents at their workplace, and 3.4% were subjected to multiple CMR exposures. Blue-collar workers, night-shift workers and workers with short-term employment contracts experienced higher exposure prevalence (p < 0.01) and intensity (p < 0.05). Bluecollar workers and shift workers experienced also longer exposure duration (p < 0.001). Conversely, managers, workers of large companies, and women were less exposed to CMR agents (p < 0.001). The presence of a Committee for Health, Safety, and Working Conditions, and intervention by Occupational Health and Safety officers were significantly associated with reduced exposure intensities (p < 0.001 and p < 0.05). Establishment of European CMR regulations and the existence of an applicable substitution principle reduced the exposure duration (p < 0.001) and intensity (p < 0.05). Our results point out disparities in CMR exposure and identify high-priority targets for prevention measures to help reducing social health discrepancies.

  19. Varied exposure to carcinogenic, mutagenic, and reprotoxic (CMR) chemicals in occupational settings in France

    International Nuclear Information System (INIS)

    Havet, Nathalie; Penot, Alexis; Morelle, Magali; Perrier, Lionel; Charbotel, Barbara; Fervers, Beatrice

    2017-01-01

    To explore varied exposure to carcinogenic, mutagenic, and reprotoxic chemicals (CMR) for French employees. Our study assessed data from the French national cross-sectional survey of occupational risks (SUMER) that was conducted in 2010 in a national representative sample of employees. We selected 28 CMR agents that were classified by the International Agency for Research on Cancer or European Union as being known or presumed to have CMR potential in humans. The association of individual and job characteristics with exposure prevalence, duration, and intensity of the CMR agents during a 1-week period was examined using multilevel logistic regression analysis. Overall, 10.4% of employees in 2010 were exposed to one or more CMR agents at their workplace, and 3.4% were subjected to multiple CMR exposures. Blue-collar workers, night-shift workers and workers with short-term employment contracts experienced higher exposure prevalence (p < 0.01) and intensity (p < 0.05). Bluecollar workers and shift workers experienced also longer exposure duration (p < 0.001). Conversely, managers, workers of large companies, and women were less exposed to CMR agents (p < 0.001). The presence of a Committee for Health, Safety, and Working Conditions, and intervention by Occupational Health and Safety officers were significantly associated with reduced exposure intensities (p < 0.001 and p < 0.05). Establishment of European CMR regulations and the existence of an applicable substitution principle reduced the exposure duration (p < 0.001) and intensity (p < 0.05). Our results point out disparities in CMR exposure and identify high-priority targets for prevention measures to help reducing social health discrepancies.

  20. Multiple shell pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.

    1988-01-01

    A method is described of fabricating a pressure vessel comprising the steps of: attaching a first inner pressure vessel having means defining inlet and outlet openings to a top flange, placing a second inner pressure vessel, having means defining inlet and outlet opening, concentric with and spaced about the first inner pressure vessel and attaching the second inner pressure vessel to the top flange, placing an outer pressure vessel, having inlet and outlet openings, concentric with and spaced apart about the second inner pressure vessel and attaching the outer pressure vessel to the top flange, attaching a generally cylindrical inner inlet conduit and a generally cylindrical inner outlet conduit respectively to the inlet and outlet openings in the first inner pressure vessel, attaching a generally cylindrical outer inlet conduit and a generally cylindrical outer outlet conduit respectively to the inlet and outlet opening in the second inner pressure vessel, heating the assembled pressure vessel to a temperature above the melting point of a material selected from the group, lead, tin, antimony, bismuth, potassium, sodium, boron and mixtures thereof, filling the space between the first inner pressure vessel and the second inner pressure vessel with material selected from the group, filling the space between the second inner pressure vessel and the outer pressure vessel with material selected from the group, and pressurizing the material filling the spaces between the pressure vessels to a predetermined pressure, the step comprising: pressurizing the spaces to a pressure whereby the wall of the first inner pressure vessel is maintained in compression during steady state operation of the pressure vessel

  1. Simulated Microgravity Regulates Gene Transcript Profiles of 2T3 Preosteoblasts: Comparison of the Random Positioning Machine and the Rotating Wall Vessel Bioreactor

    Science.gov (United States)

    Patel, Mamta J.; Liu, Wenbin; Sykes, Michelle C.; Ward, Nancy E.; Risin, Semyon A.; Risin, Diana; Hanjoong, Jo

    2007-01-01

    Microgravity of spaceflight induces bone loss due in part to decreased bone formation by osteoblasts. We have previously examined the microgravity-induced changes in gene expression profiles in 2T3 preosteoblasts using the Random Positioning Machine (RPM) to simulate microgravity conditions. Here, we hypothesized that exposure of preosteoblasts to an independent microgravity simulator, the Rotating Wall Vessel (RWV), induces similar changes in differentiation and gene transcript profiles, resulting in a more confined list of gravi-sensitive genes that may play a role in bone formation. In comparison to static 1g controls, exposure of 2T3 cells to RWV for 3 days inhibited alkaline phosphatase activity, a marker of differentiation, and downregulated 61 genes and upregulated 45 genes by more than two-fold as shown by microarray analysis. The microarray results were confirmed with real time PCR for downregulated genes osteomodulin, bone morphogenic protein 4 (BMP4), runx2, and parathyroid hormone receptor 1. Western blot analysis validated the expression of three downregulated genes, BMP4, peroxiredoxin IV, and osteoglycin, and one upregulated gene peroxiredoxin I. Comparison of the microarrays from the RPM and the RWV studies identified 14 gravi-sensitive genes that changed in the same direction in both systems. Further comparison of our results to a published database showing gene transcript profiles of mechanically loaded mouse tibiae revealed 16 genes upregulated by the loading that were shown to be downregulated by RWV and RPM. These mechanosensitive genes identified by the comparative studies may provide novel insights into understanding the mechanisms regulating bone formation and potential targets of countermeasure against decreased bone formation both in astronauts and in general patients with musculoskeletal disorders.

  2. Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE

    International Nuclear Information System (INIS)

    Gao, Hao; Luo, Xiaoyu; Allan, Andrew; McComb, Christie; Berry, Colin

    2014-01-01

    Measurement of local strain provides insight into the biomechanical significance of viable myocardium. We attempted to estimate myocardial strain from cine cardiovascular magnetic resonance (CMR) images by using a b-spline deformable image registration method. Three healthy volunteers and 41 patients with either recent or chronic myocardial infarction (MI) were studied at 1.5 Tesla with both cine and DENSE CMR. Regional circumferential and radial left ventricular strains were estimated from cine and DENSE acquisitions. In all healthy volunteers, there was no difference for peak circumferential strain (− 0.18 ± 0.04 versus − 0.18 ± 0.03, p = 0.76) between cine and DENSE CMR, however peak radial strain was overestimated from cine (0.84 ± 0.37 versus 0.49 ± 0.2, p < 0.01). In the patient study, the peak strain patterns predicted by cine were similar to the patterns from DENSE, including the strain evolution related to recovery time and strain patterns related to MI scar extent. Furthermore, cine-derived strain disclosed different strain patterns in MI and non-MI regions, and regions with transmural and non-transmural MI as DENSE. Although there were large variations with radial strain measurements from cine CMR images, useful circumferential strain information can be obtained from routine clinical CMR imaging. Cine strain analysis has potential to improve the diagnostic yield from routine CMR imaging in clinical practice. (paper)

  3. Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE.

    Science.gov (United States)

    Gao, Hao; Allan, Andrew; McComb, Christie; Luo, Xiaoyu; Berry, Colin

    2014-07-07

    Measurement of local strain provides insight into the biomechanical significance of viable myocardium. We attempted to estimate myocardial strain from cine cardiovascular magnetic resonance (CMR) images by using a b-spline deformable image registration method. Three healthy volunteers and 41 patients with either recent or chronic myocardial infarction (MI) were studied at 1.5 Tesla with both cine and DENSE CMR. Regional circumferential and radial left ventricular strains were estimated from cine and DENSE acquisitions. In all healthy volunteers, there was no difference for peak circumferential strain (- 0.18 ± 0.04 versus - 0.18 ± 0.03, p = 0.76) between cine and DENSE CMR, however peak radial strain was overestimated from cine (0.84 ± 0.37 versus 0.49 ± 0.2, p cine were similar to the patterns from DENSE, including the strain evolution related to recovery time and strain patterns related to MI scar extent. Furthermore, cine-derived strain disclosed different strain patterns in MI and non-MI regions, and regions with transmural and non-transmural MI as DENSE. Although there were large variations with radial strain measurements from cine CMR images, useful circumferential strain information can be obtained from routine clinical CMR imaging. Cine strain analysis has potential to improve the diagnostic yield from routine CMR imaging in clinical practice.

  4. The association of lesion eccentricity with plaque morphology and components in the superficial femoral artery: a high-spatial-resolution, multi-contrast weighted CMR study

    Directory of Open Access Journals (Sweden)

    Zhao Xihai

    2010-07-01

    Full Text Available Abstract Background Atherosclerotic plaque morphology and components are predictors of subsequent cardiovascular events. However, associations of plaque eccentricity with plaque morphology and plaque composition are unclear. This study investigated associations of plaque eccentricity with plaque components and morphology in the proximal superficial femoral artery using cardiovascular magnetic resonance (CMR. Methods Twenty-eight subjects with an ankle-brachial index less than 1.00 were examined with 1.5T high-spatial-resolution, multi-contrast weighted CMR. One hundred and eighty diseased locations of the proximal superficial femoral artery (about 40 mm were analyzed. The eccentric lesion was defined as [(Maximum wall thickness- Minimum wall thickness/Maximum wall thickness] ≥ 0.5. The arterial morphology and plaque components were measured using semi-automatic image analysis software. Results One hundred and fifteen locations were identified as eccentric lesions and sixty-five as concentric lesions. The eccentric lesions had larger wall but similar lumen areas, larger mean and maximum wall thicknesses, and more calcification and lipid rich necrotic core, compared to concentric lesions. For lesions with the same lumen area, the degree of eccentricity was associated with an increased wall area. Eccentricity (dichotomous as eccentric or concentric was independently correlated with the prevalence of calcification (odds ratio 3.78, 95% CI 1.47-9.70 after adjustment for atherosclerotic risk factors and wall area. Conclusions Plaque eccentricity is associated with preserved lumen size and advanced plaque features such as larger plaque burden, more lipid content, and increased calcification in the superficial femoral artery.

  5. Automated assessments of circumferential strain from cine CMR correlate with LVEF declines in cancer patients early after receipt of cardio-toxic chemotherapy.

    Science.gov (United States)

    Jolly, Marie-Pierre; Jordan, Jennifer H; Meléndez, Giselle C; McNeal, Gary R; D'Agostino, Ralph B; Hundley, W Gregory

    2017-08-02

    In patients with cancer receiving potentially cardio-toxic chemotherapy, measurements of left ventricular (LV) circumferential or longitudinal strain are often used clinically to identify myocardial dysfunction. Using a new software algorithm, we sought to determine in individuals receiving treatment for cancer the association between automated assessments of LV mean mid-wall circumferential strain and conventional measures of LV ejection fraction (EF) both obtained from cardiovascular magnetic resonance (CMR) cine balanced steady-state free-precession (bSSFP) white-blood acquisitions. Before and 3 months after initiating treatment with potentially cardio-toxic chemotherapy, 72 individuals (aged 54 ± 14 years with breast cancer [39%], lymphoma [49%], or sarcoma [12%]) underwent serial CMR cine bSSFP assessments of LV volumes and EF, and mean mid-wall circumferential strain determined from these same cine images as well as from additional tagged CMR images. On the cine images, assessments of strain were obtained using the newly developed deformation-based segmentation algorithm. Assessments of LV volumes/EF from the cine images and strain from tagged CMR were accomplished using commercially available software. All measures were analyzed in a blinded fashion independent of one another. Acceptable measures for the automated assessments of mean mid-wall circumferential strain from the cine images were obtained in 142 of 144 visits (98.6%) with an overall analysis time averaging 6:47 ± 1:06 min. The results from these automated measures averaged -18.8 ± 2.9 at baseline and -17.6 ± 3.1 at 3 months (p = 0.001). Left ventricular EF declined slightly from 65 ± 7% at baseline to 62 ± 7% at 3 months (p = 0.0002). The correlation between strain from cine imaging and LVEF was r = -0.61 (p cine and tagged derived assessments of strain was r = 0.23; p = 0.01. Automated measures of LV mean mid-wall circumferential strain can be obtained in 6

  6. Nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Blackstone, E.G.; Lofy, R.A.; Williams, L.P.

    1979-01-01

    Apparatus for the in situ inspection of a nuclear reactor vessel to detect the location and character of flaws in the walls of the vessel, in the welds joining the various sections of the vessel, in the welds joining attachments such as nozzles, elbows and the like to the reactor vessel and in such attachments wherein an inspection head carrying one or more ultrasonic transducers follows predetermined paths in scanning the various reactor sections, welds and attachments

  7. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  8. Advanced myocardial tissue characterisation by a multi-component CMR protocol in patients with rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Greulich, Simon; Kaesemann, Philipp; Patrascu, Alexandru; Sechtem, Udo; Mahrholdt, Heiko [Robert-Bosch-Medical Center Stuttgart, Division of Cardiology, Stuttgart (Germany); Mayr, Agnes [University Hospital Innsbruck, Division of Radiology, Innsbruck (Austria); Kitterer, Daniel; Latus, Joerg; Braun, Niko; Alscher, M.D. [Robert-Bosch-Medical Center Stuttgart, Division of Nephrology, Department of Internal Medicine, Stuttgart (Germany); Henes, Joerg [University Hospital Tuebingen, Centre for Interdisciplinary Clinical Immunology, Rheumatology and Auto-inflammatory Diseases and Department of Internal Medicine II (Oncology, Haematology, Immunology, Rheumatology, Pulmology), Tuebingen (Germany); Vecchio, Francesco [Robert-Bosch-Medical Center Stuttgart, Division of Cardiology, Stuttgart (Germany); Universita degli Studi di Roma ' ' Tor Vergata' ' , Division of Cardiology, Rome (Italy); Greiser, Andreas; Groeninger, Stefan [Siemens Healthcare GmbH, Erlangen (Germany); Romeo, Francesco [Universita degli Studi di Roma ' ' Tor Vergata' ' , Division of Cardiology, Rome (Italy)

    2017-11-15

    Rheumatoid arthritis (RA) patients are at increased risk of suffering from adverse cardiovascular events. Cardiovascular magnetic resonance (CMR) mapping techniques might be appropriate tools to complement late gadolinium enhancement (LGE) for the assessment of myocardial involvement. This study aimed to perform advanced myocardial tissue characterisation in RA patients by a multicomponent CMR protocol. 22 RA patients were prospectively enrolled and underwent CMR, including LGE and T1/T2 mapping sequences; 20 volunteers served as controls. Mean LV-EF was 66%; prevalence of LGE was 18%. RA patients had increased native T1 (985 vs. 959 ms, p = 0.03), expanded extracellular volume (ECV) (27 vs. 25%, p = 0.02) and higher T2 values (52 vs. 49 ms, p < 0.001) compared to controls irrespective of the presence of LGE. T2 mapping showed the highest prevalence of values beyond the 95% percentile of controls. RA patients demonstrated higher T1, ECV and T2 values compared to controls, with most significant differences for T2. Since these results seem to be independent of the presence of LGE, advanced myocardial tissue characterisation including CMR mapping techniques in addition to LGE-CMR might be useful in the evaluation of myocardial involvement in RA patients. (orig.)

  9. In-vessel tritium

    International Nuclear Information System (INIS)

    Ueda, Yoshio; Ohya, Kaoru; Ashikawa, Naoko; Ito, Atsushi M.; Kato, Daiji; Kawamura, Gakushi; Takayama, Arimichi; Tomita, Yukihiro; Nakamura, Hiroaki; Ono, Tadayoshi; Kawashima, Hisato; Shimizu, Katsuhiro; Takizuka, Tomonori; Nakano, Tomohide; Nakamura, Makoto; Hoshino, Kazuo; Kenmotsu, Takahiro; Wada, Motoi; Saito, Seiki; Takagi, Ikuji; Tanaka, Yasunori; Tanabe, Tetsuo; Yoshida, Masafumi; Toma, Mitsunori; Hatayama, Akiyoshi; Homma, Yuki; Tolstikhina, Inga Yu.

    2012-01-01

    The in-vessel tritium research is closely related to the plasma-materials interaction. It deals with the edge-plasma-wall interaction, the wall erosion, transport and re-deposition of neutral particles and the effect of neutral particles on the fuel recycling. Since the in-vessel tritium shows a complex nonlinear behavior, there remain many unsolved problems. So far, behaviors of in-vessel tritium have been investigated by two groups A01 and A02. The A01 group performed experiments on accumulation and recovery of tritium in thermonuclear fusion reactors and the A02 group studied theory and simulation on the in-vessel tritium behavior. In the present article, outcomes of the research are reviewed. (author)

  10. CRISPR/Cas and Cmr modules, mobility and evolution of adaptive immune systems

    DEFF Research Database (Denmark)

    Shah, Shiraz Ali; Garrett, Roger Antony

    2011-01-01

    CRISPR/Cas and CRISPR/Cmr immune machineries of archaea and bacteria provide an adaptive and effective defence mechanism directed specifically against viruses and plasmids. Present data suggest that both CRISPR/Cas and Cmr modules can behave like integral genetic elements. They tend to be located...... in the more variable regions of chromosomes and are displaced by genome shuffling mechanisms including transposition. CRISPR loci may be broken up and dispersed in chromosomes by transposons with the potential for creating genetic novelty. Both CRISPR/Cas and Cmr modules appear to exchange readily between...... the significant barriers imposed by their differing conjugative, transcriptional and translational mechanisms. There are parallels between the CRISPR crRNAs and eukaryal siRNAs, most notably to germ cell piRNAs which are directed, with the help of effector proteins, to silence or destroy transposons...

  11. Evaluation of contrast wash-in and peak enhancement in adenosine first pass perfusion CMR in patients post bypass surgery

    Directory of Open Access Journals (Sweden)

    Schnackenburg Bernhard

    2010-05-01

    Full Text Available Abstract Background Adenosine first pass perfusion cardiovascular magnetic resonance (CMR yields excellent results for the detection of significant coronary artery disease (CAD. In patients with coronary artery bypass grafts (CABG the kinetics of a contrast bolus may by altered only due to different distances through the bypass grafts compared to native vessels, thereby possibly imitating a perfusion defect. The aim of the study was to evaluate semiquantitative perfusion parameters in order to assess possible differences in epicardial contrast kinetics in areas supplied by native coronaries and CABG, both without significant stenosis. Methods Twenty patients with invasive exclusion of significant CAD (control group and 38 patients with CABG without angiographically significant (≥50% stenosis in unbypassed coronaries or grafts were retrospectively included in the study. They underwent adenosine first pass (0.05 mmol/kg Gd-DTPA perfusion (3 short axis views/heart beat and late gadolinium enhancement (LGE imaging 1 day before invasive coronary angiography. Areas perfused by native coronaries and/or the different bypasses were identified in X-ray angiography using the 16 segment model. In each of these areas upslope and maximal signal intensity (SImax relative to the left ventricular parameters, time to 50% maximal signal intensity (TSI50%max and time to maximal signal intensity (TSImax were calculated. Results In areas perfused by coronary arteries with bypasses compared to native coronaries relative upslope and relative SImax did not show a significant difference. TSI50%max and TSImax in native coronaries and bypasses were 7.2s ± 1.9s vs. 7.5s ± 1.9s (p max resulted in a significant (p Conclusion Adenosine perfusion CMR in patients post CABG may be associated with a short delay in contrast arrival. However, once the contrast is in the myocardium there is similar wash-in kinetics and peak enhancement. Therefore, since the delay is only short

  12. Routine cine-CMR for prosthesis-associated mitral regurgitation: a multicenter comparison to echocardiography.

    Science.gov (United States)

    Simprini, Lauren A; Afroz, Anika; Cooper, Mitchell A; Klem, Igor; Jensen, Christoph; Kim, Raymond J; Srichai, Monvadi B; Heitner, John F; Sood, Michael; Chandy, Elizabeth; Shah, Dipan J; Lopez-Mattei, Juan; Biederman, Robert W; Grizzard, John D; Fuisz, Anthon; Ghafourian, Kambiz; Farzaneh-Far, Afshin; Weinsaft, Jonathan

    2014-09-01

    Mitral regurgitation (MR) is an important complication after prosthetic mitral valve (PMV) implantation. Transthoracic echocardiography is widely used to screen for native MR, but can be limited with PMV. Cine-cardiac magnetic resonance (CMR) holds the potential for the non-invasive assessment of regurgitant severity based on MR-induced inter-voxel dephasing. The study aim was to evaluate routine cine-CMR for the visual assessment of PMV-associated MR. Routine cine-CMR was performed at nine sites. A uniform protocol was used to grade MR based on jet size in relation to the left atrium (mild 2/3). MR was graded in each long-axis orientation, with overall severity based on cumulative grade. Cine-CMR was also scored for MR density and pulmonary vein systolic flow reversal (PVSFR). Visual interpretation was compared to quantitative analysis in a single-center (derivation) cohort, and to transesophageal echocardiography (TEE) in a multicenter (validation) cohort. The population comprised 85 PMV patients (59% mechanical valves, 41% bioprostheses). Among the derivation cohort (n = 25), quantitative indices paralleled visual scores, with stepwise increases in jet size and density in relation to visually graded MR severity (both p = 0.001). Patients with severe MR had an almost three-fold increase in quantitative jet area (p = 0.002), and a two-fold increase in density (p = 0.04) than did other patients. Among the multicenter cohort, cine-CMR and TEE (Δ =. 2 ± 3 days) demonstrated moderate agreement (κ = 0.44); 64% of discordances differed by ≤ 1 grade (Δ = 1.2 ± 0.5). Using a TEE reference, cine-CMR yielded excellent diagnostic performance for severe MR (sensitivity, negative predictive value = 100%). Patients with visually graded severe MR also had more frequent PVSFR (p cine-CMR. Cine-CMR is useful for the assessment of PMV-associated MR, which manifests concordant quantitative and qualitative changes in size and density of inter-voxel dephasing. Visual MR

  13. Routine Cine-CMR for Prosthesis Associated Mitral Regurgitation – A Multicenter Comparison to Echocardiography

    Science.gov (United States)

    Simprini, Lauren A.; Afroz, Anika; Cooper, Mitchell A.; Klem, Igor; Jensen, Christoph; Kim, Raymond J.; Srichai, Monvadi B.; Heitner, John F.; Sood, Michael; Chandy, Elizabeth; Shah, Dipan J.; Lopez-Mattei, Juan; Biederman, Robert W.; Grizzard, John D.; Fuisz, Anthon; Ghafourian, Kambiz; Farzaneh-Far, Afshin; Weinsaft, Jonathan

    2016-01-01

    Background/Aim MR is an important complication after PMV. Transthoracic echocardiography is widely used to screen for native MR, but can be limited with PMV. Cine-CMR holds potential to non-invasively assess regurgitant severity based on MR-induced inter-voxel dephasing. This study evaluated routine cine-CMR for visual assessment of prosthetic mitral valve (PMV) associated mitral regurgitation (MR). Methods Routine cine-CMR was performed at 9 sites. A uniform protocol was used to grade MR based on jet size in relation to the left atrium (mild 2/3): MR was graded in each long axis orientation, with overall severity based on cumulative grade. Cine-CMR was also scored for MR density and pulmonary vein systolic flow reversal (PSFR). Visual interpretation was compared to quantitative analysis in a single center (derivation) cohort, and to transesophageal echocardiography (TEE) in a multicenter (validation) cohort. Results The population comprised 85 PMV patients (59% mechanical, 41% bioprosthetic). Among the derivation cohort (n=25), quantitative indices paralleled visual scores, with stepwise increases in jet size and density in relation to visually graded MR severity (both p=0.001): Patients with severe MR had nearly a 3-fold increase in quantitative jet area (p=0.002), and 2-fold increase in density (p=0.04) than did others. Among the multicenter cohort, cine-CMR and TEE (Δ=2±3 days) demonstrated moderate agreement (κ=0.44); 64% of discordances differed by ≤ 1 grade (Δ=1.2±0.5). Using a TEE reference, cine-CMR yielded excellent diagnostic performance for severe MR (sensitivity, negative predictive value=100%). Patients with visually graded severe MR also had more frequent PVSFR (pcine-CMR. Conclusions Cine-CMR is useful for assessment of PMV-associated MR, which manifests concordant quantitative and qualitative changes in size and density of inter-voxel dephasing. Visual MR assessment based on jet size provides an accurate non-invasive means of screening for

  14. Involvement of phenazines and biosurfactants in biocontrol of Pythium myriotylum root rot on cocoyam by Pseudomonas sp. CMR12A

    Science.gov (United States)

    Pseudomonas sp. CMR12a was isolated from the rhizosphere of the tropical tuber crop cocoyam and produces both phenazines and cyclic lipopeptide (CLP) biosurfactants. CMR12a was shown to be an efficient biocontrol agent of P. myriotylum on cocoyam. To assess the importance of phenazine and biosurfact...

  15. Cardiovascular magnetic resonance imaging (CMR) reveals characteristic pattern of myocardial damage in patients with mitochondrial myopathy.

    Science.gov (United States)

    Yilmaz, Ali; Gdynia, Hans-Jürgen; Ponfick, Matthias; Rösch, Sabine; Lindner, Alfred; Ludolph, Albert C; Sechtem, Udo

    2012-04-01

    Mitochondrial myopathy comprises various clinical subforms of neuromuscular disorders that are characterised by impaired mitochondrial energy metabolism due to dysfunction of the mitochondrial respiratory chain. No comprehensive and targeted cardiovascular magnetic resonance (CMR) studies have been performed so far in patients with mitochondrial disorders. The present study aimed at characterising cardiac disease manifestations in patients with mitochondrial myopathy and elucidating the in vivo cardiac damage pattern of patients with different subforms of mitochondrial disease by CMR studies. In a prospective study, 37 patients with mitochondrial myopathy underwent comprehensive neurological and cardiac evaluations including physical examination, resting ECG and CMR. The CMR studies comprised cine-CMR, T2-weighted "edema" imaging and T1-weighted late-gadolinium-enhancement (LGE) imaging. Various patterns and degrees of skeletal myopathy were present in the participants of this study, whereas clinical symptoms such as chest pain symptoms (in eight (22%) patients) and various degrees of dyspnea (in 16 (43%) patients) were less frequent. Pathological ECG findings were documented in eight (22%) patients. T2-weighted "edema" imaging was positive in one (3%) patient with MELAS (mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes) only. LGE imaging demonstrated the presence of non-ischemic LGE in 12 (32%) patients: 10 out of 24 (42%) patients with CPEO (chronic progressive external ophthalmoplegia) or KSS (Kearns-Sayre syndrome) and 2 of 3 (67%) patients with MELAS were LGE positive. All 10 LGE-positive patients with CPEO or KSS demonstrated a potentially typical pattern of diffuse intramural LGE in the left-ventricular (LV) inferolateral segments. Cardiac involvement is a frequent finding in patients with mitochondrial myopathy. A potentially characteristic pattern of diffuse intramural LGE in the LV inferolateral segments was identified in

  16. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Kurita, Gen-ichi; Onozuka, Masaki; Suzuki, Masaru.

    1997-01-01

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and γ rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  17. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Kurita, Gen-ichi [Japan Atomic Energy Research Inst., Tokyo (Japan); Onozuka, Masaki; Suzuki, Masaru

    1997-07-31

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and {gamma} rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  18. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using CMR: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Seed Mike

    2012-11-01

    Full Text Available Abstract Background We present the first phase contrast (PC cardiovascular magnetic resonance (CMR measurements of the distribution of blood flow in twelve late gestation human fetuses. These were obtained using a retrospective gating technique known as metric optimised gating (MOG. Methods A validation experiment was performed in five adult volunteers where conventional cardiac gating was compared with MOG. Linear regression and Bland Altman plots were used to compare MOG with the gold standard of conventional gating. Measurements using MOG were then made in twelve normal fetuses at a median gestational age of 37 weeks (range 30–39 weeks. Flow was measured in the major fetal vessels and indexed to the fetal weight. Results There was good correlation between the conventional gated and MOG measurements in the adult validation experiment (R=0.96. Mean flows in ml/min/kg with standard deviations in the major fetal vessels were as follows: combined ventricular output (CVO 540±101, main pulmonary artery (MPA 327±68, ascending aorta (AAo 198±38, superior vena cava (SVC 147±46, ductus arteriosus (DA 220±39,pulmonary blood flow (PBF 106±59,descending aorta (DAo 273±85, umbilical vein (UV 160±62, foramen ovale (FO107±54. Results expressed as mean percentages of the CVO with standard deviations were as follows: MPA 60±4, AAo37±4, SVC 28±7, DA 41±8, PBF 19±10, DAo50±12, UV 30±9, FO 21±12. Conclusion This study demonstrates how PC CMR with MOG is a feasible technique for measuring the distribution of the normal human fetal circulation in late pregnancy. Our preliminary results are in keeping with findings from previous experimental work in fetal lambs.

  19. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using CMR: a cross-sectional study.

    Science.gov (United States)

    Seed, Mike; van Amerom, Joshua F P; Yoo, Shi-Joon; Al Nafisi, Bahiyah; Grosse-Wortmann, Lars; Jaeggi, Edgar; Jansz, Michael S; Macgowan, Christopher K

    2012-11-26

    We present the first phase contrast (PC) cardiovascular magnetic resonance (CMR) measurements of the distribution of blood flow in twelve late gestation human fetuses. These were obtained using a retrospective gating technique known as metric optimised gating (MOG). A validation experiment was performed in five adult volunteers where conventional cardiac gating was compared with MOG. Linear regression and Bland Altman plots were used to compare MOG with the gold standard of conventional gating. Measurements using MOG were then made in twelve normal fetuses at a median gestational age of 37 weeks (range 30-39 weeks). Flow was measured in the major fetal vessels and indexed to the fetal weight. There was good correlation between the conventional gated and MOG measurements in the adult validation experiment (R=0.96). Mean flows in ml/min/kg with standard deviations in the major fetal vessels were as follows: combined ventricular output (CVO) 540 ± 101, main pulmonary artery (MPA) 327 ± 68, ascending aorta (AAo) 198 ± 38, superior vena cava (SVC) 147 ± 46, ductus arteriosus (DA) 220 ± 39,pulmonary blood flow (PBF) 106 ± 59,descending aorta (DAo) 273 ± 85, umbilical vein (UV) 160 ± 62, foramen ovale (FO)107 ± 54. Results expressed as mean percentages of the CVO with standard deviations were as follows: MPA 60 ± 4, AAo37 ± 4, SVC 28 ± 7, DA 41 ± 8, PBF 19 ± 10, DAo50 ± 12, UV 30 ± 9, FO 21 ± 12. This study demonstrates how PC CMR with MOG is a feasible technique for measuring the distribution of the normal human fetal circulation in late pregnancy. Our preliminary results are in keeping with findings from previous experimental work in fetal lambs.

  20. Novel structural features drive DNA binding properties of Cmr, a CRP family protein in TB complex mycobacteria.

    Science.gov (United States)

    Ranganathan, Sridevi; Cheung, Jonah; Cassidy, Michael; Ginter, Christopher; Pata, Janice D; McDonough, Kathleen A

    2018-01-09

    Mycobacterium tuberculosis (Mtb) encodes two CRP/FNR family transcription factors (TF) that contribute to virulence, Cmr (Rv1675c) and CRPMt (Rv3676). Prior studies identified distinct chromosomal binding profiles for each TF despite their recognizing overlapping DNA motifs. The present study shows that Cmr binding specificity is determined by discriminator nucleotides at motif positions 4 and 13. X-ray crystallography and targeted mutational analyses identified an arginine-rich loop that expands Cmr's DNA interactions beyond the classical helix-turn-helix contacts common to all CRP/FNR family members and facilitates binding to imperfect DNA sequences. Cmr binding to DNA results in a pronounced asymmetric bending of the DNA and its high level of cooperativity is consistent with DNA-facilitated dimerization. A unique N-terminal extension inserts between the DNA binding and dimerization domains, partially occluding the site where the canonical cAMP binding pocket is found. However, an unstructured region of this N-terminus may help modulate Cmr activity in response to cellular signals. Cmr's multiple levels of DNA interaction likely enhance its ability to integrate diverse gene regulatory signals, while its novel structural features establish Cmr as an atypical CRP/FNR family member. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  1. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    Science.gov (United States)

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory

  2. Effects of High-sugar and High-fat Diet on Fat Deposition and Blood Vessel Wall on Sprague Dawley Rats Liver

    Directory of Open Access Journals (Sweden)

    Vera Citra Setiawan Hoei

    2013-11-01

    Full Text Available People nowadays tend to consume more fast food and sweetened beverages. These foods usually contain high amount sugar and fat that have effects on the body including liver.This study was conducted to explore the effects of extensive intake of sugar and fat on blood glucose and  cholesterol level as well as changes in liver. Research was conducted with experimental method using 20 Sprague Dawley rats which were divided into 4 groups; 2 controls and 2 treatments. Rats were given 5 ml sugar or lard alternatively every 2 consecutive days for 1-month and 2-month respectively. Data was retrieved include blood glucose and cholesterol level, fatty liver percentage and blood vessel thickening after intervention through HE staining. The results showed that both 1-month and 2-month intervention group has significant increase in blood glucose and cholesterol level. However, the enhancement of fatty liver percentage and number of thickened blood vessels (p<0.05 were only foundsignificant (p<0.05 in 1-month intervention group.  We concluded that high intake of sugar and fat within 1-monthintervention have significant effects on the rat body including liver. Nevertheless, it was not found significant in 2-months intervention. Further studies are still needed to analyze this incongruent result.Key words: high-sugar diet, high-fat diet, fatty liver, atherosclerosis 

  3. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    The role of the research vessels as a tool for marine research and exploration is very important. Technical requirements of a suitable vessel and the laboratories needed on board are discussed. The history and the research work carried out...

  4. Vacuum vessel for plasma devices

    International Nuclear Information System (INIS)

    Yamada, Masao; Taguchi, Masami.

    1975-01-01

    Object: To permit effective utility of the space in the inner and outer sides of the container wall and also permit repeated assembly for use. Structure: Vacuum vessel wall sections are sealed together by means of welding bellows, and also flange portions formed at the end of the wall sections are coupled together by bolts and are sealed together with a seal ring and a seal cap secured by welding. (Nakamura, S.)

  5. Motion compensated cine CMR of the fetal heart using radial undersampling and compressed sensing

    OpenAIRE

    Roy, Christopher W.; Seed, Mike; Kingdom, John C.; Macgowan, Christopher K.

    2017-01-01

    Background To develop and evaluate a reconstruction framework for high resolution time-resolved CMR of the fetal heart in the presence of motion. Methods Data were acquired using a golden angle radial trajectory in seven fetal subjects and reconstructed as real-time images to detect fetal movement. Data acquired during through-plane motion were discarded whereas in-plane motion was corrected. A fetal cardiac gating signal was extracted to sort the corrected data by cardiac phase, allowing rec...

  6. Probability mapping of scarred myocardium using texture and intensity features in CMR images

    Science.gov (United States)

    2013-01-01

    Background The myocardium exhibits heterogeneous nature due to scarring after Myocardial Infarction (MI). In Cardiac Magnetic Resonance (CMR) imaging, Late Gadolinium (LG) contrast agent enhances the intensity of scarred area in the myocardium. Methods In this paper, we propose a probability mapping technique using Texture and Intensity features to describe heterogeneous nature of the scarred myocardium in Cardiac Magnetic Resonance (CMR) images after Myocardial Infarction (MI). Scarred tissue and non-scarred tissue are represented with high and low probabilities, respectively. Intermediate values possibly indicate areas where the scarred and healthy tissues are interwoven. The probability map of scarred myocardium is calculated by using a probability function based on Bayes rule. Any set of features can be used in the probability function. Results In the present study, we demonstrate the use of two different types of features. One is based on the mean intensity of pixel and the other on underlying texture information of the scarred and non-scarred myocardium. Examples of probability maps computed using the mean intensity of pixel and the underlying texture information are presented. We hypothesize that the probability mapping of myocardium offers alternate visualization, possibly showing the details with physiological significance difficult to detect visually in the original CMR image. Conclusion The probability mapping obtained from the two features provides a way to define different cardiac segments which offer a way to identify areas in the myocardium of diagnostic importance (like core and border areas in scarred myocardium). PMID:24053280

  7. Voluntary Consensus Organization Standards for Nondestructive Evaluation of Thin-Walled Metallic Liners and Composite Overwraps in Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Waller, Jess; Saulsberry, Regor

    2012-01-01

    NASA fracture control requirements outlined in NASA-STD-5009 and NASA-STD-5014 are predicated on the availability and use of sensitive nondestructive evaluation (NDE) methods that can detect and monitor defects, thereby providing data that can be used to predict failure or reduce the risk of failure in fracture critical components. However, in the case of composite materials and components, including composite overwrapped pressure vessels (COPVs), the effect of defects is poorly understood, the NDE methods used to evaluate locate and size defects are typically at lower technical readiness level than analogous NDE methods used for metals, and demonstration studies to verify the probability of detection (POD) are generally lacking or unavailable. These factors together make failure prediction of fracture critical composite materials and components based on size, quantity, or orientation of defects nearly impossible. Also, when inspecting metal liners in as-manufactured COPVs, sensitivity is lost and only the inner surface of the liner is accessible. Also, NDE of COPVs as applied during manufacturing varies significantly from manufacturer to manufacturer and has not yet been standardized. Although requirements exist to perform NDE immediately after manufacturing to establish initial integrity of the parts, procedural detail for NDE of composites is still nonexistent or under development. For example, in practice, only a visual inspection of COPVs is performed during manufacturing and service, leaving in question whether defects of concern, for example, bridging, overwrap winding anomalies, impact damage below visible threshold, out-of-family strain growth, and liner buckling have been adequately detected and monitored. To address these shortcomings, in 2005 the NASA Nondestructive Evaluation Working Group (NNWG) began funding work to develop and adopt standards for nondestructive evaluation of aerospace composites in collaboration with the American Society for Testing

  8. Modelling of in-vessel retention after relocation of corium into the lower plenum - Evaluation of the temperature field and of the viscoplastic deformation of the vessel wall. Reactor safety research, project No.:150 1254 - Final report; Beitrag zur Modellierung der Schmelzerueckhaltung im RDB nach Verlagerung von Corium in das untere Plenum - Berechnung des Temperaturfeldes und der viskoplastischen Verformung der Behaelterwand. Reaktorsicherheitsforschung, Vorhaben-Nr.: 150 1254 - Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Altstadt, E.; Willschuetz, H.G. [Forschungszentrum Rossendorf e.V. (FZR), Dresden (Germany)

    2005-01-01

    Considering the hypothetical core melt down scenario for a light water reactor (LWR) a possible failure mode of the reactor pressure vessel (RPV) and its failure time has to be investigated for a determination of the loadings on the containment. Several experiments have been performed accompanied with material properties evaluation, theoretical, and numerical work. At the Institute Of Safety Research of the FZR a finite element model has been developed simulating the thermal processes and the viscoplastic behaviour of the vessel wall. An advanced model for creep and material damage has been established and has been validated using experimental data. The thermal hydraulic and the mechanical calculations are sequentially and recursively coupled. The model is capable of evaluating fracture time and fracture position of a vessel with an internally heated melt pool. The model was applied to pre- and post test calculations for the FOREVER test series representing the RPV of a PWR in the scale of 1:10. These experiments were performed at the Royal Institute of Technology in Stockholm. The results of the calculations can be summarised as follows: The creeping process is caused by the simultaneous presence of high temperature (>600 C) and pressure (>1 MPa). The hot focus region is the most endangered zone exhibiting the highest creep strain rates. The exact level of temperature and pressure has an influence on the vessel failure time but not on the failure position. The failure time can be predicted with an uncertainty of 20 to 25%. This uncertainty is caused by the large scatter and the high temperature sensitivity of the viscoplastic properties of the RPV steel. Contrary to the hot focus region, the lower centre of the vessel head exhibits a higher strength because of the lower temperatures in this zone. The lower part moves down without significant deformation. Therefore it can be assumed, that the vessel failure can be retarded or prevented by supporting this range. The

  9. Radioactive liquid containing vessel

    International Nuclear Information System (INIS)

    Sakurada, Tetsuo; Kawamura, Hironobu.

    1993-01-01

    Cooling jackets are coiled around the outer circumference of a container vessel, and the outer circumference thereof is covered with a surrounding plate. A liquid of good conductivity (for example, water) is filled between the cooling jackets and the surrounding plate. A radioactive liquid is supplied to the container vessel passing through a supply pipe and discharged passing through a discharge pipe. Cooling water at high pressure is passed through the cooling water jackets in order to remove the heat generated from the radioactive liquid. Since cooling water at high pressure is thus passed through the coiled pipes, the wall thickness of the container vessel and the cooling water jackets can be reduced, thereby enabling to reduce the cost. Further, even if the radioactive liquid is leaked, there is no worry of contaminating cooling water, to prevent contamination. (I.N.)

  10. Development of PWR pressure vessel steels

    International Nuclear Information System (INIS)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed

  11. Development of PWR pressure vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed.

  12. Novel 3D ultrasound image-based biomarkers based on a feature selection from a 2D standardized vessel wall thickness map: a tool for sensitive assessment of therapies for carotid atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, Bernard; Bing, Li; Chow, Tommy W S, E-mail: bcychiu@cityu.edu.hk, E-mail: bingli5@student.cityu.edu.hk, E-mail: eetchow@cityu.edu.hk [Department of Electronic Engineering, City University of Hong Kong (Hong Kong)

    2013-09-07

    With the advent of new therapies and management strategies for carotid atherosclerosis, there is a parallel need for measurement tools or biomarkers to evaluate the efficacy of these new strategies. 3D ultrasound has been shown to provide reproducible measurements of plaque area/volume and vessel wall volume. However, since carotid atherosclerosis is a focal disease that predominantly occurs at bifurcations, biomarkers based on local plaque change may be more sensitive than global volumetric measurements in demonstrating efficacy of new therapies. The ultimate goal of this paper is to develop a biomarker that is based on the local distribution of vessel-wall-plus-plaque thickness change (VWT-Change) that has occurred during the course of a clinical study. To allow comparison between different treatment groups, the VWT-Change distribution of each subject must first be mapped to a standardized domain. In this study, we developed a technique to map the 3D VWT-Change distribution to a 2D standardized template. We then applied a feature selection technique to identify regions on the 2D standardized map on which subjects in different treatment groups exhibit greater difference in VWT-Change. The proposed algorithm was applied to analyse the VWT-Change of 20 subjects in a placebo-controlled study of the effect of atorvastatin (Lipitor). The average VWT-Change for each subject was computed (i) over all points in the 2D map and (ii) over feature points only. For the average computed over all points, 97 subjects per group would be required to detect an effect size of 25% that of atorvastatin in a six-month study. The sample size is reduced to 25 subjects if the average were computed over feature points only. The introduction of this sensitive quantification technique for carotid atherosclerosis progression/regression would allow many proof-of-principle studies to be performed before a more costly and longer study involving a larger population is held to confirm the treatment

  13. Novel 3D ultrasound image-based biomarkers based on a feature selection from a 2D standardized vessel wall thickness map: a tool for sensitive assessment of therapies for carotid atherosclerosis

    International Nuclear Information System (INIS)

    Chiu, Bernard; Li Bing; Chow, Tommy W S

    2013-01-01

    With the advent of new therapies and management strategies for carotid atherosclerosis, there is a parallel need for measurement tools or biomarkers to evaluate the efficacy of these new strategies. 3D ultrasound has been shown to provide reproducible measurements of plaque area/volume and vessel wall volume. However, since carotid atherosclerosis is a focal disease that predominantly occurs at bifurcations, biomarkers based on local plaque change may be more sensitive than global volumetric measurements in demonstrating efficacy of new therapies. The ultimate goal of this paper is to develop a biomarker that is based on the local distribution of vessel-wall-plus-plaque thickness change (VWT-Change) that has occurred during the course of a clinical study. To allow comparison between different treatment groups, the VWT-Change distribution of each subject must first be mapped to a standardized domain. In this study, we developed a technique to map the 3D VWT-Change distribution to a 2D standardized template. We then applied a feature selection technique to identify regions on the 2D standardized map on which subjects in different treatment groups exhibit greater difference in VWT-Change. The proposed algorithm was applied to analyse the VWT-Change of 20 subjects in a placebo-controlled study of the effect of atorvastatin (Lipitor). The average VWT-Change for each subject was computed (i) over all points in the 2D map and (ii) over feature points only. For the average computed over all points, 97 subjects per group would be required to detect an effect size of 25% that of atorvastatin in a six-month study. The sample size is reduced to 25 subjects if the average were computed over feature points only. The introduction of this sensitive quantification technique for carotid atherosclerosis progression/regression would allow many proof-of-principle studies to be performed before a more costly and longer study involving a larger population is held to confirm the treatment

  14. Nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    This patent describes an improved liquid metal nuclear reactor construction comprising: (a) a nuclear reactor core having a bottom platform support structure; (b) a reactor vessel for holding a large pool of low pressure liquid metal coolant and housing the core; (c) a containment structure surrounding the reactor vessel and having a sidewall spaced outwardly from the reactor vessel side wall and having a base mat spaced below the reactor vessel bottom end wall; (d) a central small diameter post anchored to the containment structure base mat and extending upwardly to the reactor vessel to axially fix the bottom end wall of the reactor vessel and provide a center column support for the lower end of the reactor core; (e) annular support structure disposed in the reactor vessel on the bottom end wall and extending about the lower end of the core; (f) structural support means disposed between the containment structure base mat and bottom end of the reactor vessel wall and cooperating for supporting the reactor vessel at its bottom end wall on the containment structure base mat to allow the reactor vessel to expand radially but substantially prevent any lateral motions that might be imposed by the occurrence of a seismic event; (g) a bed of insulating material disposed between the containment structure base mat and the bottom end wall of the reactor vessel and uniformly supporting the reactor vessel at its bottom end wall; freely expand radially from the central post as it heats up while providing continuous support thereof; (h) a deck supported upon the wall of the containment vessel above the top open end of the reactor vessel; and (i) extendible and retractable coupling means extending between the deck and the top open end of the reactor vessel and flexibly and sealably interconnecting the reactor vessel at its top end to the deck

  15. A tight binding model study of tunneling conductance spectra of spin and orbitally ordered CMR manganites

    Science.gov (United States)

    Panda, Saswati; Sahoo, D. D.; Rout, G. C.

    2018-04-01

    We report here a tight binding model for colossal magnetoresistive (CMR) manganites to study the pseudo gap (PG) behavior near Fermi level. In the Kubo-Ohata type DE model, we consider first and second nearest neighbor interactions for transverse spin fluctuations in core band and hopping integrals in conduction band, in the presence of static band Jahn-Teller distortion. The model Hamiltonian is solved using Zubarev's Green's function technique. The electron density of states (DOS) is found out from the Green's functions. We observe clear PG near Fermi level in the electron DOS.

  16. Contrast-enhanced CMR in patients after percutaneous closure of the left atrial appendage: A pilot study

    Directory of Open Access Journals (Sweden)

    Petersen Steffen E

    2011-07-01

    Full Text Available Abstract Background To evaluate the feasibility and value of first-pass contrast-enhanced dynamic and post-contrast 3D CMR in patients after transcatheter occlusion of left atrial appendage (LAA to identify incorrect placement and persistent leaks. Methods 7 patients with different occluder systems (n = 4 PLAATO; n = 2 Watchman; n = 1 ACP underwent 2 contrast-enhanced (Gd-DOTA CMR sequences (2D TrueFISP first-pass perfusion and 3D-TurboFLASH to assess localization, artifact size and potential leaks of the devices. Perfusion CMR was analyzed visually and semi-quantitatively to identify potential leaks. Results All occluders were positioned within the LAA. The ACP occluder presented the most extensive artifact size. Visual assessment revealed a residual perfusion of the LAA apex in 4 cases using first-pass perfusion and 3D-TurboFLASH indicating a suboptimal LAA occlusion. By assessing signal-to-time-curves the cases with a visually detected leak showed a 9-fold higher signal-peak in the LAA apex (567 ± 120% increase from baseline signal than those without a leak (61 ± 22%; p Conclusion This CMR pilot study provides valuable non-invasive information in patients after transcatheter occlusion of the LAA to identify correct placement and potential leaks. We recommend incorporating CMR in future clinical studies to evaluate new device types.

  17. PWR vessel inspection performance improvements

    International Nuclear Information System (INIS)

    Blair Fairbrother, D.; Bodson, Francis

    1998-01-01

    A compact robot for ultrasonic inspection of reactor vessels has been developed that reduces setup logistics and schedule time for mandatory code inspections. Rather than installing a large structure to access the entire weld inspection area from its flange attachment, the compact robot examines welds in overlapping patches from a suction cup anchor to the shell wall. The compact robot size allows two robots to be operated in the vessel simultaneously. This significantly reduces the time required to complete the inspection. Experience to date indicates that time for vessel examinations can be reduced to fewer than four days. (author)

  18. Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation.

    Science.gov (United States)

    Mekkaoui, Choukri; Huang, Shuning; Chen, Howard H; Dai, Guangping; Reese, Timothy G; Kostis, William J; Thiagalingam, Aravinda; Maurovich-Horvat, Pal; Ruskin, Jeremy N; Hoffmann, Udo; Jackowski, Marcel P; Sosnovik, David E

    2012-10-12

    The study of myofiber reorganization in the remote zone after myocardial infarction has been performed in 2D. Microstructural reorganization in remodeled hearts, however, can only be fully appreciated by considering myofibers as continuous 3D entities. The aim of this study was therefore to develop a technique for quantitative 3D diffusion CMR tractography of the heart, and to apply this method to quantify fiber architecture in the remote zone of remodeled hearts. Diffusion Tensor CMR of normal human, sheep, and rat hearts, as well as infarcted sheep hearts was performed ex vivo. Fiber tracts were generated with a fourth-order Runge-Kutta integration technique and classified statistically by the median, mean, maximum, or minimum helix angle (HA) along the tract. An index of tract coherence was derived from the relationship between these HA statistics. Histological validation was performed using phase-contrast microscopy. In normal hearts, the subendocardial and subepicardial myofibers had a positive and negative HA, respectively, forming a symmetric distribution around the midmyocardium. However, in the remote zone of the infarcted hearts, a significant positive shift in HA was observed. The ratio between negative and positive HA variance was reduced from 0.96 ± 0.16 in normal hearts to 0.22 ± 0.08 in the remote zone of the remodeled hearts (p layers of the myocardium. Tractography-based quantification, performed here for the first time in remodeled hearts, may provide a framework for assessing regional changes in the left ventricle following infarction.

  19. Pressure vessel for nuclear reactors

    International Nuclear Information System (INIS)

    1975-01-01

    The invention applies to a pressure vessel for nuclear reactors whose shell, made of cast metal segments, has a steel liner. This liner must be constructed to withstand all operational stresses and to be easily repairable. The invention solves this problem by installing the liner at a certain distance from the inner wall of the pressure vessel shell and by filling this clearance with supporting concrete. Both the concrete and the steel liner must have a lower prestress than the pressure vessel shell. In order to avoid damage to the liner when prestressing the pressure vessel shell, special connecting elements are provided which consist of welded-on fastening elements projecting into recesses in the cast metal segments of the pressure vessel. Their design is described in detail. (TK) [de

  20. Nuclear reactor vessel decontamination systems

    International Nuclear Information System (INIS)

    McGuire, P. J.

    1985-01-01

    There is disclosed in the present application, a decontamination system for reactor vessels. The system is operatable without entry by personnel into the contaminated vessel before the decontamination operation is carried out and comprises an assembly which is introduced into the vertical cylindrical vessel of the typical boiling water reactor through the open top. The assembly includes a circular track which is centered by guideways permanently installed in the reactor vessel and the track guides opposed pairs of nozzles through which water under very high pressure is directed at the wall for progressively cutting and sweeping a tenacious radioactive coating as the nozzles are driven around the track in close proximity to the vessel wall. The whole assembly is hoisted to a level above the top of the vessel by a crane, outboard slides on the assembly brought into engagement with the permanent guideways and the assembly progressively lowered in the vessel as the decontamination operation progresses. The assembly also includes a low pressure nozzle which forms a spray umbrella above the high pressure nozzles to contain radioactive particles dislodged during the decontamination

  1. Cmr1/WDR76 defines a nuclear genotoxic stress body linking genome integrity and protein quality control

    DEFF Research Database (Denmark)

    Gallina, Irene; Colding, Camilla Skettrup; Henriksen, Peter

    2015-01-01

    DNA replication stress is a source of genomic instability. Here we identify changed mutation rate 1 (Cmr1) as a factor involved in the response to DNA replication stress in Saccharomyces cerevisiae and show that Cmr1-together with Mrc1/Claspin, Pph3, the chaperonin containing TCP1 (CCT) and 25...... other proteins-define a novel intranuclear quality control compartment (INQ) that sequesters misfolded, ubiquitylated and sumoylated proteins in response to genotoxic stress. The diversity of proteins that localize to INQ indicates that other biological processes such as cell cycle progression...... propose that Cmr1/WDR76 plays a role in the recovery from genotoxic stress through regulation of the turnover of sumoylated and phosphorylated proteins....

  2. Phenomenological vessel burst investigations

    International Nuclear Information System (INIS)

    Hippelein, K.W.; Julisch, P.; Muz, J.; Schiedermaier, J.

    1985-07-01

    Fourteen burst experiments have been carried out using vessels with circumferential and longitudinal flaws, for investigation of the fracture behaviour, i.e. the time-related fracture opening. The vessels had dimensions (outer diameter x wall thickness = 800 x 47 mm) which correspond to the dimensions of the main coolant piping of a 1300 MW e PWR. The test specimens had been made of the base-safe material 20 MnMoNi 55 and of a special, 22 NiMoCr 37 base alloy. The experimental conditions with regard to pressure and temperature have been chosen so as to correspond to normal operating conditions of a PWR (p∝17.5 MPa, T∝300 0 C), i.e. the flaws have been so dimensioned that failure was to be expected at a pressure of p∝17.5 MPa. As a rule, water has been used as the pressure medium, or in some cases air, in order to influence the time-dependent pressure decrease. Fluid and structural dynamics calculations have also been made. In order to determine the impact of a fast propagating crack on the leak-to-fracture curve, which normally is defined by quasistationary experiments, suitable tests have been made with large-volume, cylindrical vessels (outer diameter x wall thickness x length = 3000 x 21 x 14000 mm) made of the material WSt E 43. The leak-before-fracture criterion has been confirmed. (orig./HP) [de

  3. Optimizing {sup 18}F-FDG PET/CT imaging of vessel wall inflammation: the impact of {sup 18}F-FDG circulation time, injected dose, uptake parameters, and fasting blood glucose levels

    Energy Technology Data Exchange (ETDEWEB)

    Bucerius, Jan [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, One Gustave L. Levy Place, P.O. Box 1234, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States); Maastricht University Medical Center, Department of Nuclear Medicine, Maastricht (Netherlands); Maastricht University Medical Center, Cardiovascular Research Institute Maastricht (CARIM), Maastricht (Netherlands); University Hospital, RWTH Aachen, Department of Nuclear Medicine, Aachen (Germany); Mani, Venkatesh; Fayad, Zahi A. [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, One Gustave L. Levy Place, P.O. Box 1234, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States); Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Moncrieff, Colin [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, One Gustave L. Levy Place, P.O. Box 1234, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States); Machac, Josef [Mount Sinai School of Medicine, Division of Nuclear Medicine, Department of Radiology, New York, NY (United States); Fuster, Valentin [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); The Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid (Spain); Farkouh, Michael E. [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Mount Sinai School of Medicine, Cardiovascular Imaging Clinical Trials Unit, New York, NY (United States); Tawakol, Ahmed [Massachusetts General Hospital, Harvard University, Cardiac MR PET CT Program, Boston, MA (United States); Rudd, James H.F. [Cambridge University, Division of Cardiovascular Medicine, Cambridge (United Kingdom)

    2014-02-15

    {sup 18}F-FDG PET is increasingly used for imaging of vessel wall inflammation. However, limited data are available on the impact of methodological variables, i.e. prescan fasting glucose, FDG circulation time and injected FDG dose, and of different FDG uptake parameters, in vascular FDG PET imaging. Included in the study were 195 patients who underwent vascular FDG PET/CT of the aorta and the carotids. Arterial standardized uptake values ({sub mean}SUV{sub max}), target-to-background ratios ({sub mean}TBR{sub max}) and FDG blood-pool activity in the superior vena cava (SVC) and the jugular veins (JV) were quantified. Vascular FDG uptake values classified according to the tertiles of prescan fasting glucose levels, the FDG circulation time, and the injected FDG dose were compared using ANOVA. Multivariate regression analyses were performed to identify the potential impact of all variables described on the arterial and blood-pool FDG uptake. Tertile analyses revealed FDG circulation times of about 2.5 h and prescan glucose levels of less than 7.0 mmol/l, showing a favorable relationship between arterial and blood-pool FDG uptake. FDG circulation times showed negative associations with aortic{sub mean}SUV{sub max} values as well as SVC and JV FDG blood-pool activity, but positive correlations with aortic and carotid{sub mean}TBR{sub max} values. Prescan glucose levels were negatively associated with aortic and carotid{sub mean}TBR{sub max} and carotid{sub mean}SUV{sub max} values, but were positively correlated with SVC blood-pool uptake. The injected FDG dose failed to show any significant association with vascular FDG uptake. FDG circulation times and prescan blood glucose levels significantly affect FDG uptake in the aortic and carotid walls and may bias the results of image interpretation in patients undergoing vascular FDG PET/CT. The injected FDG dose was less critical. Therefore, circulation times of about 2.5 h and prescan glucose levels less than 7.0 mmol

  4. Concise biomarker for spatial-temporal change in three-dimensional ultrasound measurement of carotid vessel wall and plaque thickness based on a graph-based random walk framework: Towards sensitive evaluation of response to therapy.

    Science.gov (United States)

    Chiu, Bernard; Chen, Weifu; Cheng, Jieyu

    2016-12-01

    Rapid progression in total plaque area and volume measured from ultrasound images has been shown to be associated with an elevated risk of cardiovascular events. Since atherosclerosis is focal and predominantly occurring at the bifurcation, biomarkers that are able to quantify the spatial distribution of vessel-wall-plus-plaque thickness (VWT) change may allow for more sensitive detection of treatment effect. The goal of this paper is to develop simple and sensitive biomarkers to quantify the responsiveness to therapies based on the spatial distribution of VWT-Change on the entire 2D carotid standardized map previously described. Point-wise VWT-Changes computed for each patient were reordered lexicographically to a high-dimensional data node in a graph. A graph-based random walk framework was applied with the novel Weighted Cosine (WCos) similarity function introduced, which was tailored for quantification of responsiveness to therapy. The converging probability of each data node to the VWT regression template in the random walk process served as a scalar descriptor for VWT responsiveness to treatment. The WCos-based biomarker was 14 times more sensitive than the mean VWT-Change in discriminating responsive and unresponsive subjects based on the p-values obtained in T-tests. The proposed framework was extended to quantify where VWT-Change occurred by including multiple VWT-Change distribution templates representing focal changes at different regions. Experimental results show that the framework was effective in classifying carotid arteries with focal VWT-Change at different locations and may facilitate future investigations to correlate risk of cardiovascular events with the location where focal VWT-Change occurs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Containment vessel construction for nuclear power reactors

    International Nuclear Information System (INIS)

    Sulzer, H.D.; Coletti, J.L.

    1975-01-01

    A nuclear containment vessel houses an inner reactor housing structure whose outer wall is closely spaced from the inner wall of the containment vessel. The inner reactor housing structure is divided by an intermediate floor providing an upper chamber for housing the reactor and associated steam generators and a lower chamber directly therebeneath containing a pressure suppression pool. Communication between the upper chamber and the pressure suppression pool is established by conduits extending through the intermediate floor which terminate beneath the level of the pressure suppression pool and by inlet openings in the reactor housing wall beneath the level of the pressure suppression pool which communicate with the annulus formed between the outer wall of the reactor housing structure and the inner wall of the containment vessel. (Official Gazette)

  6. Using NJOY99 and MCNP4B2 to Estimate the Radiation Damage Displacements per Atom per Second in Steel Within the Boiling Water Reactor Core Shroud and Vessel Wall from Reactor-Grade Mixed-Oxide/Uranium Oxide Fuel for the Nuclear Power Plant at Laguna Verde, Veracruz, Mexico

    International Nuclear Information System (INIS)

    Vickers, Lisa

    2003-01-01

    The government of Mexico has expressed interest in utilizing the Laguna Verde boiling water reactor (BWR) nuclear power plant for the disposition of reprocessed spent uranium oxide (UOX) fuel in the form of reactor-grade mixed-oxide (MOX) fuel. MOX fuel would replace spent UOX fuel as a fraction in the core from 18 to 30% depending on the fuel loading cycle. MOX fuel is expected to increase the neutron fluence, flux, fuel centerline temperature, reactor core pressure, and yield higher energy neutrons.There is concern that a core with a fraction of MOX fuel (i.e., increased 239 Pu wt%) would increase the radiation damage displacements per atom per second (dpa-s -1 ) in steel within the core shroud and vessel wall as compared to only conventional, enriched UOX fuel in the core. The evaluation of radiation damage within the core shroud and vessel wall is a concern because of the potentially adverse affect to personnel and public safety, environment, and operating life of the reactor.The primary uniqueness of this paper is the computation of radiation damage (dpa-s -1 ) using NJOY99-processed cross sections for steel within the core shroud and vessel wall. Specifically, the unique radiation damage results are several orders of magnitude greater than results of previous works. In addition, the conclusion of this paper was that the addition of the maximum fraction of one-third MOX fuel to the LV1 BWR core did significantly increase the radiation damage in steel within the core shroud and vessel wall such that without mitigation of radiation damage by periodic thermal annealing or reduction in operating parameters such as neutron fluence, core temperature, and pressure, it posed a potentially adverse affect to the personnel and public safety, environment, and operating life of the reactor

  7. Elastic plastic buckling of elliptical vessel heads

    International Nuclear Information System (INIS)

    Alix, M.; Roche, R.L.

    1981-08-01

    The risks of buckling of dished vessel head increase when the vessel is thin walled. This paper gives the last results on experimental tests of 3 elliptical heads and compares all the results with some empirical formula dealing with elastic and plastic buckling

  8. Recommendations for a Software Quality Assurance Plan for the CMR Facility at LANL

    International Nuclear Information System (INIS)

    Adams, K.; Matthews, S. D.; McQueen, M. A.

    1998-01-01

    The Nuclear Materials Technology (NMT) organizations 1 and 3 within the Chemical and Metallurgical Research (CMR) facility at the Los Alamos National Laboratory are working to achieve Waste Isolation Pilot Plant (WIPP) certification to enable them to transport their TRU waste to WIPP. This document is intended to provide not only recommendations to address the necessary software quality assurance activities to enable the NMT-1 and NMT-3 organizations to be WIPP compliant but is also meant to provide a template for the final Software Quality Assurance Plan (SQAP). This document specifically addresses software quality assurance for all software used in support of waste characterization and analysis. Since NMT-1 and NMT-3 currently have several operational software products that are used for waste characterization and analysis, these software quality assurance recommendations apply to the operations, maintenance and retirement of the software and the creation and development of any new software required for waste characterization and analyses

  9. Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation

    Directory of Open Access Journals (Sweden)

    Mekkaoui Choukri

    2012-10-01

    Full Text Available Abstract Background The study of myofiber reorganization in the remote zone after myocardial infarction has been performed in 2D. Microstructural reorganization in remodeled hearts, however, can only be fully appreciated by considering myofibers as continuous 3D entities. The aim of this study was therefore to develop a technique for quantitative 3D diffusion CMR tractography of the heart, and to apply this method to quantify fiber architecture in the remote zone of remodeled hearts. Methods Diffusion Tensor CMR of normal human, sheep, and rat hearts, as well as infarcted sheep hearts was performed ex vivo. Fiber tracts were generated with a fourth-order Runge-Kutta integration technique and classified statistically by the median, mean, maximum, or minimum helix angle (HA along the tract. An index of tract coherence was derived from the relationship between these HA statistics. Histological validation was performed using phase-contrast microscopy. Results In normal hearts, the subendocardial and subepicardial myofibers had a positive and negative HA, respectively, forming a symmetric distribution around the midmyocardium. However, in the remote zone of the infarcted hearts, a significant positive shift in HA was observed. The ratio between negative and positive HA variance was reduced from 0.96 ± 0.16 in normal hearts to 0.22 ± 0.08 in the remote zone of the remodeled hearts (p Conclusions A significant reorganization of the 3D fiber continuum is observed in the remote zone of remodeled hearts. The positive (rightward shift in HA in the remote zone is greatest in the subepicardium, but involves all layers of the myocardium. Tractography-based quantification, performed here for the first time in remodeled hearts, may provide a framework for assessing regional changes in the left ventricle following infarction.

  10. The structural revision of piericidin A by combination of CMR spectroscopic and biosynthetic studies

    International Nuclear Information System (INIS)

    Yoshida, Shigeo; Shiraishi, Shiro; Takahashi, Nobutaka

    1977-01-01

    The structure of piericidin A was reexamined by means of the CMR spectroscopy and the 13 C feeding studies, and the structure Ia was revised to IIa. This structure was further confirmed by the selective reduction of PA and by the mass spectral analysis. Twelve signals due to sp 3 carbons were readily assigned by selective 13 C-H decoupling technique. On the other hand, assignment of five signals due to sp 2 carbons carrying a proton could not be done by the technique because five olefinic protons appear in a narrow region in the PMR spectrum of PA. This problem was solved by the introduction of ''the graphical decoupling method''. Notwithstanding that the assignment of residual signals due to eight substituted sp 2 carbons, C-3, C-7, C-11 and the piridine carbons, could not be made at this stage, the analysis of the CMR spectrum of PA afforded enough information on the recognition of two carbons in question, C-4 and C-6. Thus the signals at delta 43.2 and delta 135.9 should be assigned to C-6 and C-4 in Ia, or C-4 and C-6 in IIa respectively. Then the feeding experiments of sodium acetate-1-13C were carried out. The spectrum of 13 C-enriched PA by acetate-1- 13 C shows a clear intensified signal at delta 43.2. On the other hand, another signal at delta 135.9 was enhanced by the feeding of propionate-1- 13 C. Obviously, these evidences indicate that the signal at delta 43.2 should be assigned to C-4 and that at delta 135.9 to C-6. Therefore, IIa represents the correct structure of PA, excluding Ia. (Iwakiri, K.)

  11. Environmental assessment for the proposed CMR Building upgrades at the Los Alamos National Laboratory, Los Alamos, New Mexico. Final document

    International Nuclear Information System (INIS)

    1997-01-01

    In order to maintain its ability to continue to conduct uninterrupted radioactive and metallurgical research in a safe, secure, and environmentally sound manner, the US Department of Energy (DOE) proposes to upgrade the Los Alamos National Laboratory (LANL) Chemistry and Metallurgy Research (CMR) Building. The building was built in the early 1950s to provide a research and experimental facility for analytical chemistry, plutonium and uranium chemistry, and metallurgy. Today, research and development activities are performed involving nuclear materials. A variety of radioactive and chemical hazards are present. The CMR Building is nearing the end of its original design life and does not meet many of today's design codes and standards. The Proposed Action for this Environmental Assessment (EA) includes structural modifications to some portions of the CMR Building which do not meet current seismic criteria for a Hazard Category 2 Facility. Also included are upgrades and improvements in building ventilation, communications, monitoring, and fire protection systems. This EA analyzes the environmental effects of construction of the proposed upgrades. The Proposed Action will have no adverse effects upon agricultural and cultural resources, wetlands and floodplains, endangered and threatened species, recreational resources, or water resources. The Proposed Action would have negligible effects on human health and transportation, and would not pose a disproportionate adverse health or environmental impact on minority or low-income populations within an 80 kilometer (50 mile) radius of the CMR Building

  12. Environmental assessment for the proposed CMR Building upgrades at the Los Alamos National Laboratory, Los Alamos, New Mexico. Final document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-04

    In order to maintain its ability to continue to conduct uninterrupted radioactive and metallurgical research in a safe, secure, and environmentally sound manner, the US Department of Energy (DOE) proposes to upgrade the Los Alamos National Laboratory (LANL) Chemistry and Metallurgy Research (CMR) Building. The building was built in the early 1950s to provide a research and experimental facility for analytical chemistry, plutonium and uranium chemistry, and metallurgy. Today, research and development activities are performed involving nuclear materials. A variety of radioactive and chemical hazards are present. The CMR Building is nearing the end of its original design life and does not meet many of today`s design codes and standards. The Proposed Action for this Environmental Assessment (EA) includes structural modifications to some portions of the CMR Building which do not meet current seismic criteria for a Hazard Category 2 Facility. Also included are upgrades and improvements in building ventilation, communications, monitoring, and fire protection systems. This EA analyzes the environmental effects of construction of the proposed upgrades. The Proposed Action will have no adverse effects upon agricultural and cultural resources, wetlands and floodplains, endangered and threatened species, recreational resources, or water resources. The Proposed Action would have negligible effects on human health and transportation, and would not pose a disproportionate adverse health or environmental impact on minority or low-income populations within an 80 kilometer (50 mile) radius of the CMR Building.

  13. Comparison of exercise electrocardiography and stress perfusion CMR for the detection of coronary artery disease in women

    Directory of Open Access Journals (Sweden)

    Greulich Simon

    2012-06-01

    Full Text Available Abstract Background Exercise electrocardiography (ECG is frequently used in the work-up of patients with suspected coronary artery disease (CAD, however the accuracy is reduced in women. Cardiovascular magnetic resonance (CMR stress testing can accurately diagnose CAD in women. To date, a direct comparison of CMR to ECG has not been performed. Methods and results We prospectively enrolled 88 consecutive women with chest pain or other symptoms suggestive of CAD. Patients underwent a comprehensive clinical evaluation, exercise ECG, a CMR stress test including perfusion and infarct imaging, and x-ray coronary angiography (CA within 24 hours. CAD was defined as stenosis ≥70% on quantitative analysis of CA. Exercise ECG, CMR and CA was completed in 68 females (age 66.4 ± 8.8 years, number of CAD risk factors 3.5 ± 1.4. The prevalence of CAD on CA was 29%. The Duke treadmill score (DTS in the entire group was −3.0 ± 5.4 and was similar in those with and without CAD (−4.5 ± 5.8 and −2.4 ± 5.1; P = 0.12. Sensitivity, specificity and accuracy for CAD diagnosis was higher for CMR compared with exercise ECG (sensitivities 85% and 50%, P = 0.02, specificities 94% and 73%, P = 0.01, and accuracies 91% and 66%, P = 0.0007, respectively. Even after applying the DTS the accuracy of CMR was higher compared to exercise ECG (area under ROC curve 0.94 ± 0.03 vs 0.56 ± 0.07; P = 0.0001. Conclusions In women with intermediate-to-high risk for CAD who are able to exercise and have interpretable resting ECG, CMR stress perfusion imaging has higher accuracy for the detection of relevant obstruction of the epicardial coronaries when directly compared to exercise ECG.

  14. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-07-01

    A successful technical demonstration of simulated reactor vessel sectioning was completed using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel: an air arc gouger was chosen to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. After the simulated vessel was successfully cut from the SS side, another cut was made, starting from the carbon steel side. This cut was also successful. Cutting from the carbon steel side has the advantages of cost reduction since the air arc gouging step is eliminated and contamination controlled because the molten metal is blown inward

  15. Motional Effect on Wall Shear Stresses

    DEFF Research Database (Denmark)

    Kock, Samuel Alberg; Torben Fründ, Ernst; Yong Kim, Won

    Atherosclerosis is the leading cause of death and severe disability. Wall Shear Stress (WSS), the stress exerted on vessel walls by the flowing blood is a key factor in the development of atherosclerosis. Computational Fluid Dynamics (CFD) is widely used for WSS estimations. Most CFD simulations...... are based on static models to ease computational burden leading to inaccurate estimations. The aim of this work was to estimate the effect of vessel wall deformations (expansion and bending) on WSS levels....

  16. CMR of EEX? Van samenloop, litispendentie en het vrij verkeer van beslissingen in Europa. Hof van Justitie EU 4 mei 2010, zaak C-533/08 (TNT Express/AXA)

    NARCIS (Netherlands)

    M.A.I.H. Hoeks (Marian)

    2011-01-01

    textabstractAbstract The seed from which the problem sprouted in the TNT-AXA case is the fact that the CMR, an international road carriage convention, refers to national law in Article 29 CMR. This Article determines that if the CMR carrier has caused damage to the cargo ‘by such default on his

  17. Containment vessel

    International Nuclear Information System (INIS)

    Zbirohowski-Koscia, K.F.; Roberts, A.C.

    1980-01-01

    A concrete containment vessel for nuclear reactors is disclosed that is spherical and that has prestressing tendons disposed in first, second and third sets, the tendons of each set being all substantially concentric and centred around a respective one of the three orthogonal axes of the sphere; the tendons of the first set being anchored at each end at a first anchor rib running around a circumference of the vessel, the tendons of the second set being anchored at each end at a second anchor rib running around a circumference of the sphere and disposed at 90 0 to the first rib, and the tendons of the third set being anchored some to the first rib and the remainder to the second rib. (author)

  18. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Nagashima, Keisuke; Suzuki, Masaru; Onozuka, Masaki.

    1997-01-01

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  19. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Nagashima, Keisuke [Japan Atomic Energy Research Inst., Tokyo (Japan); Suzuki, Masaru; Onozuka, Masaki

    1997-07-11

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  20. Inspection apparatus for a vessel made of magnetic metal

    International Nuclear Information System (INIS)

    Clark, J.P.; Foster, A.C.; Smith, T.D.

    1976-01-01

    Previous systems intended for in-situ inspection of the pressure vessels of nuclear reactors are of uneasy use on encumbered surfaces. Said invention relates to a remote-control device for inspecting vessel walls. It comprises a conveyor able to be propelled, possibly around obstacles, towards any place inside the vessel; said vehicle is provided with magnetic wheels driven by an electric motor and separately controlled. The conveyor is accurately located on the vessel by using an acoustic device involving a triangular method, and consisting in an acoustic signal emitter mounted on the conveyor and at least three receiving transducers mounted on the vessel wall [fr

  1. Prestressed reactor vessel for nuclear power plants

    International Nuclear Information System (INIS)

    Schoening, J.; Schwiers, H.G.

    1982-01-01

    With usual pressure vessels for nuclear reactor plants, especially for gas-cooled nuclear reactors, the load occurring due to the inner overpressure, especially the tensile load affecting the vessel top and/or bottom, their axis of inertia being horizontal, shall be compensated without a supplementary modification in design of the top and/or the bottom. This is attained by choosing an appropriate prestressing system of the vessel wall in the field the top and/or the bottom, so that the top and/or the bottom form a tension vault directed towards the interior of the vessel. (orig.) [de

  2. Increase of cyclic durability of pressure vessels

    International Nuclear Information System (INIS)

    Vorona, V.A.; Zvezdin, Yu.I.

    1980-01-01

    The durability of multilayer pressure vessels under cyclic loading is compared with single-layer vessels. The relative conditional durability is calculated taking into account the assumption on the consequent destruction of layers and viewing a vessel wall as an indefinite plate. It is established that the durability is mainly determined by the number of layers and to a lesser degree depends on the relative size of the defect for the given layer thickness. The advantage of the multilayer vessels is the possibility of selecting layer materials so that to exclude the effect of agressive corrosion media on the strength [ru

  3. Cloud-processed 4D CMR flow imaging for pulmonary flow quantification

    Energy Technology Data Exchange (ETDEWEB)

    Chelu, Raluca G., E-mail: ralucachelu@hotmail.com [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Department of Cardiology, Erasmus MC, Rotterdam (Netherlands); Wanambiro, Kevin W. [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Department of Radiology, Aga Khan University Hospital, Nairobi (Kenya); Hsiao, Albert [Department of Radiology, University of California, San Diego, CA (United States); Swart, Laurens E. [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Department of Cardiology, Erasmus MC, Rotterdam (Netherlands); Voogd, Teun [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Hoven, Allard T. van den; Kranenburg, Matthijs van [Department of Cardiology, Erasmus MC, Rotterdam (Netherlands); Coenen, Adriaan [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Department of Cardiology, Erasmus MC, Rotterdam (Netherlands); Boccalini, Sara [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Department of Radiology, University Hospital, Genoa (Italy); Wielopolski, Piotr A. [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Vogel, Mika W. [MR Applications and Workflow – Europe, GE Healthcare B.V. Hoevelaken (Netherlands); Krestin, Gabriel P. [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Vasanawala, Shreyas S. [Department of Radiology, Stanford University, Stanford, CA (United States); Budde, Ricardo P.J. [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Department of Cardiology, Erasmus MC, Rotterdam (Netherlands); Roos-Hesselink, Jolien W. [Department of Cardiology, Erasmus MC, Rotterdam (Netherlands); Nieman, Koen [Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Department of Cardiology, Erasmus MC, Rotterdam (Netherlands)

    2016-10-15

    Highlights: • With 4D flow, any plane of interest can be interactively chosen for quantitative measurements. • Anatomical and flow data are obtained during an approximately 10-min free-breathing scan. • 4D CMR flow measurements correlated well with the 2D PC ones. • Eddy current correction is important for good results with 4D flow. - Abstract: Objectives: In this study, we evaluated a cloud-based platform for cardiac magnetic resonance (CMR) four-dimensional (4D) flow imaging, with fully integrated correction for eddy currents, Maxwell phase effects, and gradient field non-linearity, to quantify forward flow, regurgitation, and peak systolic velocity over the pulmonary artery. Methods: We prospectively recruited 52 adult patients during one-year period from July 2014. The 4D flow and planar (2D) phase-contrast (PC) were acquired during same scanning session, but 4D flow was scanned after injection of a gadolinium-based contrast agent. Eddy-currents were semi-automatically corrected using the web-based software. Flow over pulmonary valve was measured and the 4D flow values were compared against the 2D PC ones. Results: The mean forward flow was 92 (±30) ml/cycle measured with 4D flow and 86 (±29) ml/cycle measured with 2D PC, with a correlation of 0.82 and a mean difference of −6 ml/cycle (−41–29). For the regurgitant fraction the correlation was 0.85 with a mean difference of −0.95% (−17–15). Mean peak systolic velocity measured with 4D flow was 92 (±49) cm/s and 108 (±56) cm/s with 2D PC, having a correlation of 0.93 and a mean difference of 16 cm/s (−24–55). Conclusion: 4D flow imaging post-processed with an integrated cloud-based application accurately quantifies pulmonary flow. However, it may underestimate the peak systolic velocity.

  4. Cloud-processed 4D CMR flow imaging for pulmonary flow quantification

    International Nuclear Information System (INIS)

    Chelu, Raluca G.; Wanambiro, Kevin W.; Hsiao, Albert; Swart, Laurens E.; Voogd, Teun; Hoven, Allard T. van den; Kranenburg, Matthijs van; Coenen, Adriaan; Boccalini, Sara; Wielopolski, Piotr A.; Vogel, Mika W.; Krestin, Gabriel P.; Vasanawala, Shreyas S.; Budde, Ricardo P.J.; Roos-Hesselink, Jolien W.; Nieman, Koen

    2016-01-01

    Highlights: • With 4D flow, any plane of interest can be interactively chosen for quantitative measurements. • Anatomical and flow data are obtained during an approximately 10-min free-breathing scan. • 4D CMR flow measurements correlated well with the 2D PC ones. • Eddy current correction is important for good results with 4D flow. - Abstract: Objectives: In this study, we evaluated a cloud-based platform for cardiac magnetic resonance (CMR) four-dimensional (4D) flow imaging, with fully integrated correction for eddy currents, Maxwell phase effects, and gradient field non-linearity, to quantify forward flow, regurgitation, and peak systolic velocity over the pulmonary artery. Methods: We prospectively recruited 52 adult patients during one-year period from July 2014. The 4D flow and planar (2D) phase-contrast (PC) were acquired during same scanning session, but 4D flow was scanned after injection of a gadolinium-based contrast agent. Eddy-currents were semi-automatically corrected using the web-based software. Flow over pulmonary valve was measured and the 4D flow values were compared against the 2D PC ones. Results: The mean forward flow was 92 (±30) ml/cycle measured with 4D flow and 86 (±29) ml/cycle measured with 2D PC, with a correlation of 0.82 and a mean difference of −6 ml/cycle (−41–29). For the regurgitant fraction the correlation was 0.85 with a mean difference of −0.95% (−17–15). Mean peak systolic velocity measured with 4D flow was 92 (±49) cm/s and 108 (±56) cm/s with 2D PC, having a correlation of 0.93 and a mean difference of 16 cm/s (−24–55). Conclusion: 4D flow imaging post-processed with an integrated cloud-based application accurately quantifies pulmonary flow. However, it may underestimate the peak systolic velocity.

  5. On the Adequacy of API 521 Relief-Valve Sizing Method for Gas-Filled Pressure Vessels Exposed to Fire

    DEFF Research Database (Denmark)

    Andreasen, Anders; Nieto, Marcos Zan; Borroni, Filippo

    2018-01-01

    sense of security. Often the vessel wall will be weakened by high temperatures, before the PRV relieving pressure is reached. In this article, a multiparameter study has been performed taking into consideration various vessel sizes, design pressures (implicitly vessel wall thickness), vessel operating...

  6. Brain regions involved in voluntary movements as revealed by radioisotopic mapping of CBF or CMR-glucose changes

    DEFF Research Database (Denmark)

    Lassen, N A; Ingvar, D H

    1990-01-01

    Mapping of cortical and subcortical grey matter active during voluntary movements by means of measurements of local increases of CBF or CMR-Glucose is reviewed. Most of the studies concern observations in man during hand movements using the intracarotid Xenon-133 injection technique, an approach...... that only allows to image the cortex of the hemisphere on one side (the injected side) of the brain. The results show that simple static or repetitive movements mainly activate the contralateral primary hand area (MI and SI); complex preprogrammed or spontaneous purposeful movements the supplementary motor...... area SMA on both sides increase in CBF/CMR-glucose and even internally ("mentally") going through the trained movements, causes such changes; complex purposeful movements also activate the premotor cortex, a response that is bilateral with greatest response contralaterally. Studies in patients...

  7. Evaluation of a chemical risk assessment method of South Korea for chemicals classified as carcinogenic, mutagenic or reprotoxic (CMR).

    Science.gov (United States)

    Kim, Min-Uk; Byeon, Sang-Hoon

    2017-12-12

    Chemicals were used in various fields by the development of industry and science and technology. The Chemical Hazard Risk Management (CHARM) was developed to assess the risk of chemicals in South Korea. In this study, we were to evaluate the CHARM model developed for the effective management of workplace chemicals. We used 59 carcinogenic, mutagenic or reprotoxic (CMR) materials, which are both the work environment measurement result and the usage information among the manufacturer data. The CHARM model determines the risk to human health using the exposure level (based on working environment measurements or a combination of the quantity used and chemical physical properties (e.g., fugacity and volatility)), hazard (using occupational exposure limit (OEL) or Risk phrases (R-phrases)/Hazard statements (H-statements) from the Material Safety Data Sheet (MSDS)). The risk level was lower when using the results of the work environment measurement than when applying the chemical quantity and physical properties in the exposure level evaluation method. It was evaluated as grade 4 for the CMR material in the hazard class determination. The risk assessment method by R-phrases was evaluated more conservatively than the risk assessment method by OEL. And the risk assessment method by H-statements was evaluated more conservatively than the risk assessment method by R-phrases. The CHARM model was gradually conservatively assessed as it proceeded in the next step without quantitative information for individual workplaces. The CHARM is expected to help identify the risk if the hazards and exposure levels of chemicals were identified in individual workplaces. For CMR substances, although CHARM is highly evaluated for hazards, the risk is assessed to be low if exposure levels are assessed low. When evaluating the risk of highly hazardous chemicals such as CMR substances, we believe the model should be adapted to be more conservative and classify these as higher risk. This work is

  8. The TPX vacuum vessel and in-vessel components

    International Nuclear Information System (INIS)

    Heitzenroeder, P.; Bialek, J.; Ellis, R.; Kessel, C.; Liew, S.

    1994-01-01

    The Tokamak Physics Experiment (TPX) is a superconducting tokamak with double-null diverters. TPX is designed for 1,000-second discharges with the capability of being upgraded to steady state operation. High neutron yields resulting from the long duration discharges require that special consideration be given to materials and maintainability. A unique feature of the TPX is the use of a low activation, titanium alloy vacuum vessel. Double-wall vessel construction is used since it offers an efficient solution for shielding, bakeout and cooling. Contained within the vacuum vessel are the passive coil system, Plasma Facing Components (PFCs), magnetic diagnostics, and the internal control coils. All PFCs utilize carbon-carbon composites for exposed surfaces

  9. Diagnostic and Prognostic Value of CMR T1-Mapping in Patients With Heart Failure and Preserved Ejection Fraction.

    Science.gov (United States)

    Rommel, Karl-Philipp; Lücke, Christian; Lurz, Philipp

    2017-10-01

    Heart failure with preserved ejection fraction (HFpEF) presents a major challenge in modern cardiology. Although this syndrome is of increasing prevalence and is associated with unfavorable outcomes, treatment trials have failed to establish effective therapies. Currently, solutions to this dilemma are being investigated, including categorizing and characterizing patients more diversely to individualize treatment. In this regard, new imaging techniques might provide important information. Diastolic dysfunction is a diagnostic and pathophysiological cornerstone in HFpEF and is believed to be caused by systemic inflammation with the development of interstitial myocardial fibrosis and myocardial stiffening. Cardiac magnetic resonance (CMR) T 1 -mapping is a novel tool, which allows noninvasive quantification of the extracellular space and diffuse myocardial fibrosis. This review provides an overview of the potential of myocardial tissue characterization with CMR T 1 mapping in HFpEF patients, outlining its diagnostic and prognostic implications and discussing future directions. We conclude that CMR T 1 mapping is potentially an effective tool for patient characterization in large-scale epidemiological, diagnostic, and therapeutic HFpEF trials beyond traditional imaging parameters. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Neutron Assay System for Confinement Vessel Disposition

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Valdez, Jose I.; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the CVs. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of special nuclear material (SNM) in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le)100-g 239 Pu equivalent in a vessel for safeguards termination. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements.

  11. Transcription factor VdCmr1 is required for pigment production, protection from UV irradiation, and regulates expression of melanin biosynthetic genes in Verticillium dahliae.

    Science.gov (United States)

    Wang, Yonglin; Hu, Xiaoping; Fang, Yulin; Anchieta, Amy; Goldman, Polly H; Hernandez, Gustavo; Klosterman, Steven J

    2018-04-01

    Verticillium dahliae is a soilborne fungus that causes vascular wilt diseases on numerous plant species worldwide. The production of darkly melanized microsclerotia is crucial in the disease cycle of V. dahliae, as these structures allow for long-term survival in soil. Previously, transcriptomic and genomic analysis identified a cluster of genes in V. dahliae that encodes some dihydroxynaphthalene (DHN) melanin biosynthetic pathway homologues found in related fungi. In this study, we explored the roles of cluster-specific transcription factor VdCmr1, as well as two other genes within the cluster encoding a polyketide synthase (VdPKS1) and a laccase (VdLac1), enzymes at initial and endpoint steps in DHN melanin production. The results revealed that VdCmr1 and VdPKS1 are required for melanin production, but neither is required for microsclerotia production. None of the three genes were required for pathogenesis on tobacco and lettuce. Exposure of ΔVdCmr1 and wild-type strains to UV irradiation, or to high temperature (40 °C), revealed an approx. 50 % reduction of survival in the ΔVdCmr1 strain, relative to the wild-type strain, in response to either condition. Expression profiles revealed that expression of some melanin biosynthetic genes are in part dependent on VdCmr1. Combined data indicate VdCmr1 is a key regulator of melanin biosynthesis, and that via regulation of melanogenesis, VdCmr1 affects survival of V. dahliae in response to abiotic threats. We conclude with a model showing regulation of VdCmr1 by a high osmolarity glycerol response (Hog)-type MAP kinase pathway.

  12. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.I.; Kim, B.S.; Kim, D.H. [Korea Atomic Energy Research Inst., Thermal Hydraulic Safety Research, Taejon (Korea, Republic of)

    2001-07-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  13. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    International Nuclear Information System (INIS)

    Ahn, K.I.; Kim, B.S.; Kim, D.H.

    2001-01-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  14. Simulation of In-Vessel Corium Retention through External Reactor Vessel Cooling for SMART using SIMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin-Sung; Son, Donggun; Park, Rae-Joon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Thermal load analysis from the corium pool to the outer reactor vessel in the lower plenum of the reactor vessel is necessary to evaluate the effect of the IVR-ERVC during a severe accident for SMART. A computational code called SIMPLE (Sever Invessel Melt Progression in Lower plenum Environment) has been developed for analyze transient behavior of molten corium in the lower plenum, interaction between corium and coolant, and heat-up and ablation of reactor vessel wall. In this study, heat load analysis of the reactor vessel for SMART has been conducted using the SIMPLE. Transient behavior of the molten corium in the lower plenum and IVR-ERVC for SMART has been simulated using SIMPLE. Heat flux from the corium pool to the outer reactor vessel is concentrated in metallic layer by the focusing effect. As a result, metallic layer shows higher temperature than the oxidic layer. Also, vessel wall of metallic layer has been ablated by the high in-vessel temperature. Ex-vessel temperature of the metallic layer was maintained 390 K and vessel thickness was maintained 14 cm. It means that the reactor vessel integrity is maintained by the IVR-ERVC.

  15. The Combined Incremental Prognostic Value of LVEF, Late Gadolinium Enhancement, and Global Circumferential Strain Assessed by CMR.

    Science.gov (United States)

    Mordi, Ify; Bezerra, Hiram; Carrick, David; Tzemos, Nikolaos

    2015-05-01

    This study aimed to assess the incremental prognostic value of global circumferential strain (GCS), as measured using cardiac magnetic resonance (CMR) tagging, in addition to baseline clinical characteristics, left ventricular ejection fraction (LVEF), and late gadolinium enhancement (LGE), in the prediction of major adverse cardiovascular events (MACE) in an unselected cohort of patients. LVEF is a powerful predictor of mortality and is used for guiding treatment decisions. It is, however, subject to limitations. The value of GCS measured by CMR tagging in patients with suspected cardiac disease has not been fully explored despite its being considered as the gold standard noninvasive method of assessment of LV deformation. We prospectively evaluated data from 539 consecutive patients referred for CMR who underwent a CMR protocol that included cine imaging, tagging, and LGE. The primary endpoint was the prevalence of MACE, defined as a composite of all-cause mortality, heart failure-related hospitalization, and aborted sudden cardiac death. MACE occurred in 62 of 539 patients (11.5%) over a mean follow-up period of 2.2 years. History of ischemic heart disease (IHD) and beta-blocker use were both significant clinical predictors of adverse outcomes. All 3 CMR parameters were significant multivariate predictors of the primary outcome when added to significant clinical predictors (LVEF, hazard ratio [HR]: 0.96 [95% confidence interval [CI]: 0.94 to 0.99; p = 0.005]; presence of LGE, HR: 2.07 [95% CI: 1.03 to 4.14; p = 0.04]; GCS, HR: 1.11 [95% CI: 1.02 to 1.21; p = 0.041]). Global chi-square increased significantly with the addition of both LGE and GCS. Both the presence of LGE and reduced GCS had independent prognostic value in the overall cohort. Patients with LVEF ≥35% but LGE present and reduced GCS had a poor outcome similar to that in those with LVEF value. This measure could provide further risk stratification, especially in patients with mild LV impairment

  16. In-vessel core debris retention experiments. Final report

    International Nuclear Information System (INIS)

    1998-10-01

    The in-vessel cooling experimental program (Phase 1 and 2) was motivated by the survivability of the TMI lower vessel head during the TMI-2 accident. During that accident, molten debris relocation into the water filled lower head resulted in a localized hot spot in the lower head, but no lower head failure occurred. A postulated set of mechanisms which could be involved in and responsible for the survivability of the TMI lower head were identified and experimentally investigated as part of this program. These mechanisms included: the formation of a gap (contact resistance) between the relocated and frozen debris and the vessel wall was a key aspect of the in-vessel cooling mechanism; wall heatup due to the relocated debris in the presence of wall stress due to a pressure gradient across the vessel wall; gap growth due to a lack of debris adherence to the vessel wall and material creep of the heated vessel wall; and the potential for enhanced wall cooling due to gap growth. Each of these postulated mechanisms was investigated in this experimental program. This report summarizes the several insights and conclusions that were obtained from this experimental program. This report documents the entire set of five experiments completed in Phase 2 of this experimental program. Results from the Phase 1 effort were used to plan and select the Phase 2 test matrix. Conclusions from the Phase 1 and 2 experiments are identified and recommendations for future work are provided

  17. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  18. Nuclear reactor vessel fuel thermal insulating barrier

    Science.gov (United States)

    Keegan, C. Patrick; Scobel, James H.; Wright, Richard F.

    2013-03-19

    The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel that has a hemispherical lower section that increases in volume from the center line of the reactor to the outer extent of the diameter of the thermal insulating barrier and smoothly transitions up the side walls of the vessel. The space between the thermal insulating harrier and the reactor vessel forms a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive inlet valve for the cooling water includes a buoyant door that is normally maintained sealed under its own weight and floats open when the cavity is Hooded. Passively opening steam vents are also provided.

  19. Safety vessels for explosive fusion reactor

    International Nuclear Information System (INIS)

    Mineev, V.

    1994-01-01

    The failure of several types of geometrically similar cylindrical and spherical steel and glass fibers vessels filled with water or air was investigated when an explosive charge of TNT was detonated in the center. Vessels had radius 50-1000 mm, thickness of walls 2-20%. The detonation on TNT imitated energy release. The parameter: K = M/mf is a measure of the strength of the vessel where M is the mass of the vessel, and mf is the mass of TNT for which the vessel fails. This demanded 2-4 destroyed and nondestroyed shots. It may be showed that: K=A/σ f where σ f is the fracture stress of the material vessel, and A = const = F(energy TNT, characteristic of elasticity of vessel material). The chief results are the following: (1) A similar increase in the geometrical dimensions of steel vessels by a factor of 10 leads to the increase of parameter K in about 5 times and to decrease of failure deformation in 7 times (scale effect). (2) For glass fibers, scale effect is absent. (3) This problem is solved in terms of theory energetic scale effect. (4) The concept of TNT equivalent explosive makes it possible to use these investigations to evaluate the response of safety vessels for explosive fusion reactor

  20. Evaluating the systemic right ventricle by CMR: the importance of consistent and reproducible delineation of the cavity

    Directory of Open Access Journals (Sweden)

    van Dijk Arie PJ

    2008-08-01

    Full Text Available Abstract Background The method used to delineate the boundary of the right ventricle (RV, relative to the trabeculations and papillary muscles in cardiovascular magnetic resonance (CMR ventricular volume analysis, may matter more when these structures are hypertrophied than in individuals with normal cardiovascular anatomy. This study aimed to compare two methods of cavity delineation in patients with systemic RV. Methods Twenty-nine patients (mean age 34.7 ± 12.4 years with a systemic RV (12 with congenitally corrected transposition of the great arteries (ccTGA and 17 with atrially switched (TGA underwent CMR. We compared measurements of systemic RV volumes and function using two analysis protocols. The RV trabeculations and papillary muscles were either included in the calculated blood volume, the boundary drawn immediately within the apparently compacted myocardial layer, or they were manually outlined and excluded. RV stroke volume (SV calculated using each method was compared with corresponding left ventricular (LV SV. Additionally, we compared the differences in analysis time, and in intra- and inter-observer variability between the two methods. Paired samples t-test was used to test for differences in volumes, function and analysis time between the two methods. Differences in intra- and inter-observer reproducibility were tested using an extension of the Bland-Altman method. Results The inclusion of trabeculations and papillary muscles in the ventricular volume resulted in higher values for systemic RV end diastolic volume (mean difference 28.7 ± 10.6 ml, p Conclusion The choice of method for systemic RV cavity delineation significantly affected volume measurements, given the CMR acquisition and analysis systems used. We recommend delineation outside the trabeculations for routine clinical measurements of systemic RV volumes as this approach took less time and gave more reproducible measurements.

  1. Design of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.

    1995-01-01

    The ITER vacuum vessel is a major safety barrier and must support electromagnetic loads during plasma disruptions and vertical displacement events (VDE) and withstand plausible accidents without losing confinement.The vacuum vessel has a double wall structure to provide structural and electrical continuity in the toroidal direction. The inner and outer shells and poloidal stiffening ribs between them are joined by welding, which gives the vessel the required mechanical strength. The space between the shells will be filled with steel balls and plate inserts to provide additional nuclear shielding. Water flowing in this space is required to remove nuclear heat deposition, which is 0.2-2.5% of the total fusion power. The minor and major radii of the tokamak are 3.9 m and 13 m respectively, and the overall height is 15 m. The total thickness of the vessel wall structure is 0.4-0.7 m.The inboard and outboard blanket segments are supported from the vacuum vessel. The support structure is required to withstand a large total vertical force of 200-300 MN due to VDE and to allow for differential thermal expansion.The first candidate for the vacuum vessel material is Inconel 625, due to its higher electric resistivity and higher yield strength, even at high temperatures. Type 316 stainless steel is also considered a vacuum vessel material candidate, owing to its large database and because it is supported by more conventional fabrication technology. (orig.)

  2. The tight binding model study of the role of anisotropic AFM spin ordering in the charge ordered CMR manganites

    Science.gov (United States)

    Kar, J. K.; Panda, Saswati; Rout, G. C.

    2017-05-01

    We propose here a tight binding model study of the interplay between charge and spin orderings in the CMR manganites taking anisotropic effect due to electron hoppings and spin exchanges. The Hamiltonian consists of the kinetic energies of eg and t2g electrons of manganese ion. It further includes double exchange and Heisenberg interactions. The charge density wave interaction (CDW) describes an extra mechanism for the insulating character of the system. The CDW gap and spin parameters are calculated using Zubarev's Green's function technique and computed self-consistently. The results are reported in this communication.

  3. ITER vacuum vessel design and electromagnetic analysis on in-vessel components

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.; Iizuka, T.

    1995-01-01

    Major functional requirements for the vacuum vessel are to provide the first safety barrier and to support electromagnetic loads due to plasma disruptions and vertical displacement events, and to withstand plausible accidents without losing confinement. A double wall structure concept has been developed for the vacuum vessel due to its beneficial characteristics from the viewpoints of structural integrity and electrical continuity. An electromagnetic analysis of the blanket modules and the vacuum vessel has been performed to investigate force distributions on in-vessel components. According to the vertical displacement events (VDE) scenario, which assumes a critical q-value of 1.5, the total downward vertical force, induced by coupling between the eddy current and external fields, is about 110 MN. We have performed a stress analysis for the vacuum vessel using the VDE disruption forces acting on the blankets, and a maximum stress intensity of 112 MPa was obtained in the vicinity of the lower support of the vessel. (orig.)

  4. Enhanced wall pumping in JET

    International Nuclear Information System (INIS)

    Ehrenberg, J.; Harbour, P.J.

    1991-01-01

    The enhanced wall pumping phenomenon in JET is observed for hydrogen or deuterium plasmas which are moved from the outer (larger major radius) limiter position either to the inner wall or to the top/bottom wall of the vacuum vessel. This phenomenon is analysed by employing a particle recycling model which combines plasma particle transport with particle re-emission from and retention within material surfaces. The model calculates the important experimentally observable quantities, such as particle fluxes, global particle confinement time, plasma density and density profile. Good qualitative agreement is found and, within the uncertainties, the agreement is quantitative if the wall pumping is assumed to be caused by two simultaneously occurring effects: (1) Neutral particle screening at the inner wall and the top/bottom wall is larger than that at the outer limiter because of different magnetic topologies at different poloidal positions; and (2) although most of the particles (≥ 90%) impacting on the wall can be promptly re-emitted, a small fraction (≤ 10%) of them must be retained in the wall for a period of time which is similar to or larger than the global plasma particle confinement time. However, the wall particle retention time need not be different from that of the outer limiter, i.e. pumping can occur when there is no difference between the material properties of the limiter and those of the wall. (author). 45 refs, 18 figs

  5. Fast wall of thermonuclear device

    International Nuclear Information System (INIS)

    Kitamura, Kazunori.

    1990-01-01

    A protruding molten metal reservoir is disposed to a sealing vessel embedded in the armour tile of fast walls, and molten metal of low melting point such as tin, lead or alloy thereof is filled in the sealing vessel. The volume of the molten metal reservoir is determined such that the surface level of the molten metal is kept within the molten metal reservoir even when the sealed low melting point metal is solidified at room temperature. When the temperature is lowered during plasma interruption period and the sealed low melting molten metal is solidified to reduce the volume, most of the molten metal reservoir regioin constitutes a vacuum gap. However, the inner wall of the sealing vessel other than the molten metal reservior region can be kept into contact with the sealed metal. Accordingly, the temperature and the sublimation loss of the armour tile can be kept low even upon plasma heat application. (I.N.)

  6. Modeling the Thermal Mechanical Behavior of a 300 K Vacuum Vessel that is Cooled by Liquid Hydrogen in Film Boiling

    International Nuclear Information System (INIS)

    Yang, S.Q.; Green, M.A.; Lau, W.

    2004-01-01

    This report discusses the results from the rupture of a thin window that is part of a 20-liter liquid hydrogen vessel. This rupture will spill liquid hydrogen onto the walls and bottom of a 300 K cylindrical vacuum vessel. The spilled hydrogen goes into film boiling, which removes the thermal energy from the vacuum vessel wall. This report analyzes the transient heat transfer in the vessel and calculates the thermal deflection and stress that will result from the boiling liquid in contact with the vessel walls. This analysis was applied to aluminum and stainless steel vessels

  7. Differences in quantitative assessment of myocardial scar and gray zone by LGE-CMR imaging using established gray zone protocols.

    Science.gov (United States)

    Mesubi, Olurotimi; Ego-Osuala, Kelechi; Jeudy, Jean; Purtilo, James; Synowski, Stephen; Abutaleb, Ameer; Niekoop, Michelle; Abdulghani, Mohammed; Asoglu, Ramazan; See, Vincent; Saliaris, Anastasios; Shorofsky, Stephen; Dickfeld, Timm

    2015-02-01

    Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) imaging is the gold standard for myocardial scar evaluation. Heterogeneous areas of scar ('gray zone'), may serve as arrhythmogenic substrate. Various gray zone protocols have been correlated to clinical outcomes and ventricular tachycardia channels. This study assessed the quantitative differences in gray zone and scar core sizes as defined by previously validated signal intensity (SI) threshold algorithms. High quality LGE-CMR images performed in 41 cardiomyopathy patients [ischemic (33) or non-ischemic (8)] were analyzed using previously validated SI threshold methods [Full Width at Half Maximum (FWHM), n-standard deviation (NSD) and modified-FWHM]. Myocardial scar was defined as scar core and gray zone using SI thresholds based on these methods. Scar core, gray zone and total scar sizes were then computed and compared among these models. The median gray zone mass was 2-3 times larger with FWHM (15 g, IQR: 8-26 g) compared to NSD or modified-FWHM (5 g, IQR: 3-9 g; and 8 g. IQR: 6-12 g respectively, p zone extent (percentage of total scar that was gray zone) also varied significantly among the three methods, 51 % (IQR: 42-61 %), 17 % (IQR: 11-21 %) versus 38 % (IQR: 33-43 %) for FWHM, NSD and modified-FWHM respectively (p zone and scar core. Infarct core and total myocardial scar mass also differ using these methods. Further evaluation of the most accurate quantification method is needed.

  8. Adjustable guide for a testing system for reactor pressure vessels

    International Nuclear Information System (INIS)

    Seifert, W.

    1980-01-01

    The device consisting of a guide rail and a manipulator is introduced into the gap between pressure vessel wall and biological shield by means of suspending wire drums and manipulator drums. For adjustment of the device an elbow telescope is used. The guide rail is fixed to the pressure vessel wall by means of electromagnets. The movements of the manipulator with respect to the guide rail are performed with the aid of a motor. (DG) [de

  9. Interstitial Cells of Blood Vessels

    Directory of Open Access Journals (Sweden)

    Vladimír Pucovský

    2010-01-01

    Full Text Available Blood vessels are made up of several distinct cell types. Although it was originally thought that the tunica media of blood vessels was composed of a homogeneous population of fully differentiated smooth muscle cells, more recent data suggest the existence of multiple smooth muscle cell subpopulations in the vascular wall. One of the cell types contributing to this heterogeneity is the novel, irregularly shaped, noncontractile cell with thin processes, termed interstitial cell, found in the tunica media of both veins and arteries. While the principal role of interstitial cells in veins seems to be pacemaking, the role of arterial interstitial cells is less clear. This review summarises the knowledge of the functional and structural properties of vascular interstitial cells accumulated so far, offers hypotheses on their physiological role, and proposes directions for future research.

  10. Leukoaraiosis is associated with arterial wall thickness: a quantitative analysis.

    Science.gov (United States)

    Auriel, Eitan; Csiba, Laszlo; Berenyi, Ervin; Varkonyi, Ildiko; Mehes, Gabor; Kardos, Laszlo; Karni, Arnon; Bornstein, Natan M

    2012-06-01

    Leukoaraiosis refers to an age-related, abnormal appearance of the brain white matter on neuroimaging. The association between leukoaraiosis and cerebrovascular disease suggests that ischemia may be an important contributing factor; however, the pathogenesis of the condition remains controversial. We hypothesized that physical abnormalities of blood vessels might be culpable and compared the external and internal measurements of blood vessel walls between brains that demonstrated leukoaraiosis on imaging and normal control brains. Fourteen brains of individuals who had been diagnosed as having severe leukoaraiosis and five non-leukoaraiosis control brains were studied. Arterial cross-sections were evaluated by length measurements with an image analysis device. Arterial wall thickness and the ratio of the outer and inner diameters of the vessel were measured. We measured a total of 108 vessels in the leukoaraiosis group and 95 vessels in the control group. The vessel walls of the leukoaraiosis patients were an average of 5.5 µm thicker than the walls of control vessels of the same inside diameter (P = 0.0000, 95% CI 3.01-8.08) and an average of 2.3 µm thicker than walls of control vessels of the same outside diameter (P = 0.016, 95% CI 0.48-4.17). Our data provide evidence that leukoaraiosis is associated with vessel wall thickening in an additive fashion and indicate that structural vascular abnormalities are associated with leukoaraiosis. © 2011 Japanese Society of Neuropathology.

  11. Pulmonary artery pulsatility and effect on vessel diameter assessment in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Shariat, Masoud; Schantz, Daryl; Yoo, Shi-Joon; Wintersperger, Bernd J.; Seed, Mike; Alnafisi, Bahiyah; Chu, Leysia; MacGowan, Christopher K.; Amerom, Joshua van; Grosse-Wortmann, Lars

    2014-01-01

    Background: Information about thoracic vascular sizes can crucially affect clinical decision-making in cardiovascular disease. A variety of imaging techniques such as catheter angiography, contrast enhanced computed tomography (CT) and cardiac magnetic resonance imaging (CMR) are routinely used to measure vascular diameters. Traditionally, CMR black blood sequences were the main anatomical tool for visualization of vascular anatomy and still are in many centers. More recently, the vessel diameters are measured on multiplanar reconstructions derived from static magnetic resonance angiography (MRA). This study was performed to investigate the variation of vessel diameter measurements on different CMR techniques with respect to their data acquisition scheme. Methods: We recruited two groups of patients for this prospective study. One group included patients with repaired tetralogy of Fallot (TOF), with at least moderate pulmonary insufficiency and another group of patients who underwent CMR as part of a diagnostic work-up for arrhythmogenic right ventricular cardiomyopathy (ARVC). Additional images of the right pulmonary artery (RPA) were acquired in the double inversion recovery (DIR) black blood, cine steady state free precession (SSFP) and MRA. All images were reviewed by two CMR trained readers using the electronic caliper provided within the picture archiving and communication system package. The maximum diameter of each artery was recorded in millimeters with up to one decimal point. Paired t-tests and Bland–Altman plots were used for comparison of measurements between different sequences. Results: A total of 52 patients were recruited for this study, 26 patients in the TOF group (15 males, age 12.55 ± 2.9) and 26 patients in the ARVC group (15 males, age 15.6 ± 2.3). In both groups, the RPA sizes were not significantly different between the DIR images and diastolic cine SSFP (p > 0.05). Measurements on DIR were significantly smaller than those made on

  12. Pulmonary artery pulsatility and effect on vessel diameter assessment in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shariat, Masoud, E-mail: masoudshariat@gmail.com [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Schantz, Daryl, E-mail: daryl.schantz@gmail.com [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Yoo, Shi-Joon, E-mail: shi-joon.yoo@sickkids.ca [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Wintersperger, Bernd J., E-mail: bernd.wintersperger@uhn.ca [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Seed, Mike, E-mail: mike.seed@sickkids.ca [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Department of Cardiology, Hospital for Sick Children, Toronto, Ontario (Canada); Alnafisi, Bahiyah, E-mail: bahiyah.alnafisi@uhn.ca [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Chu, Leysia, E-mail: leysia_99@yahoo.com [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); MacGowan, Christopher K., E-mail: christopher.macgowan@sickkids.ca [Department of Physiology and Experimental Medicine, Hospital for Sick Children, Toronto, Ontario (Canada); Amerom, Joshua van, E-mail: Joshu.vanamerom@sickkids.ca [Department of Physiology and Experimental Medicine, Hospital for Sick Children, Toronto, Ontario (Canada); Grosse-Wortmann, Lars, E-mail: lars.grosse-wortmann@sickkids.ca [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario (Canada); Department of Cardiology, Hospital for Sick Children, Toronto, Ontario (Canada)

    2014-02-15

    Background: Information about thoracic vascular sizes can crucially affect clinical decision-making in cardiovascular disease. A variety of imaging techniques such as catheter angiography, contrast enhanced computed tomography (CT) and cardiac magnetic resonance imaging (CMR) are routinely used to measure vascular diameters. Traditionally, CMR black blood sequences were the main anatomical tool for visualization of vascular anatomy and still are in many centers. More recently, the vessel diameters are measured on multiplanar reconstructions derived from static magnetic resonance angiography (MRA). This study was performed to investigate the variation of vessel diameter measurements on different CMR techniques with respect to their data acquisition scheme. Methods: We recruited two groups of patients for this prospective study. One group included patients with repaired tetralogy of Fallot (TOF), with at least moderate pulmonary insufficiency and another group of patients who underwent CMR as part of a diagnostic work-up for arrhythmogenic right ventricular cardiomyopathy (ARVC). Additional images of the right pulmonary artery (RPA) were acquired in the double inversion recovery (DIR) black blood, cine steady state free precession (SSFP) and MRA. All images were reviewed by two CMR trained readers using the electronic caliper provided within the picture archiving and communication system package. The maximum diameter of each artery was recorded in millimeters with up to one decimal point. Paired t-tests and Bland–Altman plots were used for comparison of measurements between different sequences. Results: A total of 52 patients were recruited for this study, 26 patients in the TOF group (15 males, age 12.55 ± 2.9) and 26 patients in the ARVC group (15 males, age 15.6 ± 2.3). In both groups, the RPA sizes were not significantly different between the DIR images and diastolic cine SSFP (p > 0.05). Measurements on DIR were significantly smaller than those made on

  13. Heat treatment device for extending the life of a pressure vessel, particularly a reactor pressure vessel

    International Nuclear Information System (INIS)

    Krauss, P.; Mueller, E.; Poerner, H.; Weber, R.

    1979-01-01

    A support body in the form of an insulating cylinder is tightly sealed by connected surfaces at its outer circumference to the inner wall of the pressure vessel. It forms an annular heating space. The heat treatment or tempering of the pressure vessel takes place with the reactor space empty and screened from the outside by ceiling bolts. Heating gas or an induction winding can be used as the means of heating. (DG) [de

  14. Improved nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    An improved liquid metal nuclear reactor construction has a reactor core and a generally cylindrical reactor vessel for holding liquid metal coolant and housing the core within the pool. A generally cylindrical concrete containment structure surrounds the reactor vessel and a central support pedestal is anchored to the containment structure base mat and supports the bottom wall of the reactor vessel and the reactor core. The periphery of the reactor vessel bore is supported by an annular structure which allows thermal expansion but not seismic motion of the vessel, and a bed of thermally insulating material uniformly supports the vessel base whilst allowing expansion thereof. A guard ring prevents lateral seismic motion of the upper end of the reactor vessel. The periphery of the core is supported by an annular structure supported by the vessel base and keyed to the vessel wall so as to be able to expand but not undergo seismic motion. A deck is supported on the containment structure above the reactor vessel open top by annular bellows, the deck carrying the reactor control rods such that heating of the reactor vessel results in upward expansion against the control rods. (author)

  15. Prestressed pressure vessel for nuclear power plants

    International Nuclear Information System (INIS)

    1974-01-01

    The pressure vessel consists of a wall, a bottom, and a closure head, the wall being composed of annular segments. The closure head can be seated on the edge of the wall. Wall and closure head have got axial prestressing channels in which through-going steel tendons are arranged. They are concentrated in bundles and held above the head by anchoring devices. Within the prestressing channels of the head there are supporting jackets attached to the edge of the wall and projecting from the head through a coller. The anchoring devices, e.g. anchoring plates, may be optionally supported on the collars of the supporting jackets or on the closure head by means of auxiliary devices. The auxiliary devices for this purpose consist of extension nuts attached to the anchoring plates and closure head connecting shells. The closure head therefore may be drawn off over the anchoring devices. (DG) [de

  16. Ambiguous walls

    DEFF Research Database (Denmark)

    Mody, Astrid

    2012-01-01

    The introduction of Light Emitting Diodes (LEDs) in the built environment has encouraged myriad applications, often embedded in surfaces as an integrated part of the architecture. Thus the wall as responsive luminous skin is becoming, if not common, at least familiar. Taking into account how wall...

  17. Ambiguous walls

    DEFF Research Database (Denmark)

    Mody, Astrid

    2012-01-01

    The introduction of Light Emitting Diodes (LEDs) in the built environment has encouraged myriad applications, often embedded in surfaces as an integrated part of the architecture. Thus the wall as responsive luminous skin is becoming, if not common, at least familiar. Taking into account how walls...... have encouraged architectural thinking of enclosure, materiality, construction and inhabitation in architectural history, the paper’s aim is to define new directions for the integration of LEDs in walls, challenging the thinking of inhabitation and program. This paper introduces the notion...... of “ambiguous walls” as a more “critical” approach to design [1]. The concept of ambiguous walls refers to the diffuse status a lumious and possibly responsive wall will have. Instead of confining it can open up. Instead of having a static appearance, it becomes a context over time. Instead of being hard...

  18. Pressure vessels fabricated with high-strength wire and electroformed nickel

    Science.gov (United States)

    Roth, B.

    1966-01-01

    Metal pressure vessels of various shapes having high strength-to-weight ratios are fabricated by using known techniques of filament winding and electroforming. This eliminates nonuniform wall thickness and unequal wall strength which resulted from welding formed vessel segments together.

  19. Probabilistic retinal vessel segmentation

    Science.gov (United States)

    Wu, Chang-Hua; Agam, Gady

    2007-03-01

    Optic fundus assessment is widely used for diagnosing vascular and non-vascular pathology. Inspection of the retinal vasculature may reveal hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. Due to various imaging conditions retinal images may be degraded. Consequently, the enhancement of such images and vessels in them is an important task with direct clinical applications. We propose a novel technique for vessel enhancement in retinal images that is capable of enhancing vessel junctions in addition to linear vessel segments. This is an extension of vessel filters we have previously developed for vessel enhancement in thoracic CT scans. The proposed approach is based on probabilistic models which can discern vessels and junctions. Evaluation shows the proposed filter is better than several known techniques and is comparable to the state of the art when evaluated on a standard dataset. A ridge-based vessel tracking process is applied on the enhanced image to demonstrate the effectiveness of the enhancement filter.

  20. Initial phase wall conditioning in KSTAR

    International Nuclear Information System (INIS)

    Hong, Suk-Ho; Kim, Kwang-Pyo; Kim, Sungwoo; Lee, Dong-Su; Kim, Kyung-Min; Lee, Kun-Su; Kim, Jong-Su; Park, Jae-Min; Kim, Woong-Chae; Kim, Hak-Kun; Park, Kap-Rai; Yang, Hyung-Lyeol; Sun, Jong-Ho; Woo, Hyun-Jong; Lee, Sang-Yong; Lee, Sang-Hwa; Park, Eun-Kyung; Park, Sang-Joon; Kim, Sun-Ho; Wang, Sun-Jung

    2011-01-01

    The initial phase wall conditioning in KSTAR is depicted. The KSTAR wall conditioning procedure consists of vessel baking, glow discharge cleaning (GDC), ICRH wall conditioning (ICWC) and boronization (Bz). Vessel baking is performed for the initial vacuum conditioning in order to remove various kinds of impurities including H 2 O, carbon and oxygen and for the plasma operation. The total outgassing rates after vessel baking in three successive KSTAR campaigns are compared. GDC is regularly performed as a standard wall cleaning procedure. Another cleaning technique is ICWC, which is useful for inter-shot wall conditioning under a strong magnetic field. In order to optimize the operation time and removal efficiency of ICWC, a parameter scan is performed. Bz is a standard technique to remove oxygen impurity from a vacuum vessel. KSTAR has used carborane powder which is a non-toxic boron-containing material. The KSTAR Bz has been successfully performed through two campaigns: water and oxygen levels in the vacuum vessel are reduced significantly. As a result, KSTAR has achieved its first L-H mode transition, although the input power was marginal for the L-H transition threshold. The characteristics of boron-containing thin films deposited for boronization are investigated.

  1. Improvement to reactor vessel

    International Nuclear Information System (INIS)

    1974-01-01

    The vessel described includes a prestressed concrete vessel containing a chamber and a removable cover closing this chamber. The cover is in concrete and is kept in its closed position by main and auxiliary retainers, comprising fittings integral with the concrete of the vessel. The auxiliary retainers pass through the concrete of the cover. This improvement may be applied to BWR, PWR and LMFBR type reactor vessel [fr

  2. Certifying the decommissioned Shippingport reactor vessel for transport

    International Nuclear Information System (INIS)

    Towell, R.H.

    1990-01-01

    The decommissioned Shippingport reactor pressure vessel with its concentric neutron shield tank was shipped to Hanford, WA as part of the effort to restore the Shippingport Station to its original condition. The metal walls of the reactor vessel had become radioactive from neutron bombardment while the reactor was operating so it had to be shipped under the regulations for transporting radioactive material. Because of the large amount of radioactivity in the walls, 16,467 Curies, and because the potentially dispersible corrosion layer on the inner walls of both tanks was also radioactive, the Shippingport reactor vessel was transported under the most stringent of the regulations, those for a type B package. Compliance with the packaging regulations was confirmed via independent analysis by the staff of the Department of Energy certifying official and the Shippingport reactor vessel was shipped under DOE Certificate of Compliance USA/9515/B(U)

  3. Myocardial deformation assessed by longitudinal strain. Chamber specific normative data for CMR-feature tracking from the German competence network for congenital heart defects

    International Nuclear Information System (INIS)

    Shang, Quanliang; Patel, Shivani; Danford, David A.; Kutty, Shelby; Steinmetz, Michael; Schuster, Andreas; Beerbaum, Philipp; Sarikouch, Samir

    2018-01-01

    Left ventricular two-dimensional global longitudinal strain (LS) is superior to ejection fraction (EF) as predictor of outcome. We provide reference data for atrial and ventricular global LS during childhood and adolescence by CMR feature tracking (FT). We prospectively enrolled 115 healthy subjects (56 male, mean age 12.4 ± 4.1 years) at a single institution. CMR consisted of standard two-dimensional steady-state free-precession acquisitions. CMR-FT was performed on ventricular horizontal long-axis images for derivation of right and left atrial (RA, LA) and right and left ventricular (RV, LV) peak global LS. End-diastolic volumes (EDVs) and EF were measured. Correlations were explored for LS with age, EDV and EF of each chamber. Mean±SD of LS (%) for RA, RV, LA and LV were 26.56±10.2, -17.96±5.4, 26.45±10.6 and -17.47±5, respectively. There was a positive correlation of LS in LA, LV, RA and RV with corresponding EF (all P<0.05); correlations with age were weak. Gender-wise differences were not significant for atrial and ventricular LS, strain rate and displacement. Inter- and intra-observer comparisons showed moderate agreements. Chamber-specific nomograms for paediatric atrial and ventricular LS are provided to serve as clinical reference, and to facilitate CMR-based deformation research. (orig.)

  4. Myocardial deformation assessed by longitudinal strain. Chamber specific normative data for CMR-feature tracking from the German competence network for congenital heart defects

    Energy Technology Data Exchange (ETDEWEB)

    Shang, Quanliang [University of Nebraska College of Medicine, Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Central South University, Department of Radiology, Second Xiangya Hospital, Changsha, Hunan Province (China); Patel, Shivani; Danford, David A.; Kutty, Shelby [University of Nebraska College of Medicine, Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Steinmetz, Michael [Georg-August-University and German Centre for Cardiovascular Research (DZHK, Partner Site), Department of Paediatric Cardiology, Goettingen (Germany); Schuster, Andreas [Georg-August-University and German Centre for Cardiovascular Research (DZHK, Partner Site), Department of Cardiology and Pulmonology, Goettingen (Germany); Beerbaum, Philipp; Sarikouch, Samir [Hanover Medical School, Hanover (Germany)

    2018-03-15

    Left ventricular two-dimensional global longitudinal strain (LS) is superior to ejection fraction (EF) as predictor of outcome. We provide reference data for atrial and ventricular global LS during childhood and adolescence by CMR feature tracking (FT). We prospectively enrolled 115 healthy subjects (56 male, mean age 12.4 ± 4.1 years) at a single institution. CMR consisted of standard two-dimensional steady-state free-precession acquisitions. CMR-FT was performed on ventricular horizontal long-axis images for derivation of right and left atrial (RA, LA) and right and left ventricular (RV, LV) peak global LS. End-diastolic volumes (EDVs) and EF were measured. Correlations were explored for LS with age, EDV and EF of each chamber. Mean±SD of LS (%) for RA, RV, LA and LV were 26.56±10.2, -17.96±5.4, 26.45±10.6 and -17.47±5, respectively. There was a positive correlation of LS in LA, LV, RA and RV with corresponding EF (all P<0.05); correlations with age were weak. Gender-wise differences were not significant for atrial and ventricular LS, strain rate and displacement. Inter- and intra-observer comparisons showed moderate agreements. Chamber-specific nomograms for paediatric atrial and ventricular LS are provided to serve as clinical reference, and to facilitate CMR-based deformation research. (orig.)

  5. The adventitia: essential regulator of vascular wall structure and function.

    Science.gov (United States)

    Stenmark, Kurt R; Yeager, Michael E; El Kasmi, Karim C; Nozik-Grayck, Eva; Gerasimovskaya, Evgenia V; Li, Min; Riddle, Suzette R; Frid, Maria G

    2013-01-01

    The vascular adventitia acts as a biological processing center for the retrieval, integration, storage, and release of key regulators of vessel wall function. It is the most complex compartment of the vessel wall and is composed of a variety of cells, including fibroblasts, immunomodulatory cells (dendritic cells and macrophages), progenitor cells, vasa vasorum endothelial cells and pericytes, and adrenergic nerves. In response to vascular stress or injury, resident adventitial cells are often the first to be activated and reprogrammed to influence the tone and structure of the vessel wall; to initiate and perpetuate chronic vascular inflammation; and to stimulate expansion of the vasa vasorum, which can act as a conduit for continued inflammatory and progenitor cell delivery to the vessel wall. This review presents the current evidence demonstrating that the adventitia acts as a key regulator of vascular wall function and structure from the outside in.

  6. Cardiac magnetic resonance and the need for routine cardiac catheterization in single ventricle patients prior to Fontan: a comparison of 3 groups: pre-Fontan CMR versus cath evaluation.

    Science.gov (United States)

    Fogel, Mark A; Pawlowski, Thomas W; Whitehead, Kevin K; Harris, Matthew A; Keller, Marc S; Glatz, Andrew C; Zhu, Winnie; Shore, David; Diaz, Laura K; Rome, Jonathan J

    2012-09-18

    This study investigated whether cardiac magnetic resonance (CMR) and echocardiography (echo) can replace catheterization (cath) for routine evaluation prior to Fontan and under what circumstances CMR and cath are used together. Routine cath prior to Fontan has been utilized for years; noninvasive methods, however, may be sufficient. This study reviews clinical data in 119 consecutive patients investigating 3 groups: those who underwent CMR alone (MR; n = 41), cath alone (C; n = 41), or both cath and CMR (C+M; n = 37) prior to Fontan. No clinically significant differences were noted in patient characteristics, hemodynamics, or clinical status prior to or after surgery between the C and MR groups. CMR added information in 82%. There were no discrepant findings between CMR and cath data in the C+M group. Diagnostic success was ≥95% in all groups. Of those undergoing Fontan completion, the C+M group had similar outcomes to C and MR; C and CMR were utilized in combination to assess aortopulmonary collaterals or the need for an intervention or evaluate its success. Echo could not delineate pulmonary arterial anatomy in 46% to 53% of patients. The C+M and C groups were exposed to 6.8 ± 4.1 mSv of radiation. Single ventricle patients not requiring an intervention can undergo successful Fontan completion with CMR and echo alone with similar short-term outcomes to C, which was used as a control, preventing an invasive test and exposure to radiation. CMR can add information in a significant number of patients. Cath and CMR are utilized together for interventions and assessment of aortopulmonary collaterals. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Manufacture, testing and assembly preparation of the JET vacuum vessel

    International Nuclear Information System (INIS)

    Arbez, J.; Baeumel, S.; Dean, J.R.; Duesling, G.; Froger, C.; Hemmerich, J.L.; Walravens, M.; Walter, K.; Winkel, T.

    1983-01-01

    To reach the target pressure of 10 -9 mbar, JET's double-walled Inconel vacuum vessel is being manufactured and assembled in clean conditions and with meticulous leak detection. Each octant (1/8 of the torus) is baked in an oven to 520 0 C and leak tested at 350 0 C to reveal leaks as small as 10 -9 mbar l/s, which are repaired. In service the vessel will be baked periodically to 500 0 C by CO 2 passing between its walls. The single-walled ports will be electrically heated. (author)

  8. Behavior of platelets stained by 5,6-CF-encapsulated PEGylated liposomes after laser irradiation of vessel wall: an in-vivo model for studying site-selective delivery of diagnostic or therapeutic agents

    Science.gov (United States)

    Mordon, Serge R.; Begu, Sylvie; Buys, Bruno; Tourne-Peteilh, Corine; Devoisselle, Jean-Marie

    2001-05-01

    Vascular endothelium serves as an extensive interface between circulating blood and various tissues and organs of the body. As such, it offers an accessible target for blood-borne pharmacological and genetic manipulations that can mediate both local and systemic effects. Thus, targeting of liposomes to activated vascular endothelial cells may provide a strategy for site-selective delivery in the vascular system with broad therapeutic applicability. This study aimed to evaluate an intravital fluorescence imaging technique to visualize in-situ and in real-time the activation of platelets after staining by 5,6-CF- encapsulated PEGylated liposomes injected intravenously. The study was performed on skin by using a dorsal skin-fold chamber implanted in golden hamsters using intravital microscopy. The skin micro circulation was observed with an intravital microscope (using x25 and x40 magnification) fitted with a Xenon light source and an epi-fluorescence assembly. An ultra-high sensitivity video-camera mounted on the microscope projected the image onto a monitor, and the images were recorded for play-back analysis with a digital video cassette recorder. An inflammatory response was induced by an Argon laser emitting at 514.5nm. The 80micrometers laser beam was focused on a vessel and its position was controlled with the microscope imaging system, it was possible to see individual platelets flowing in blood vessels. As liposomes were labeled with a fluorescent probe which was hydrophilic (located in the aqueous phase), the fluorescence of platelets was due only to the uptake of liposomes. After laser irradiation, platelets activation at sites of vascular injury was obtained. Tethering, translocation of some platelets inside the irradiated zone were clearly seen. At last, detachment and extravasation of platelets were observed. A perivascular fluorescence confirmed that platelets migrated across the basal lamina into the dermal connective tissue. In conclusion, staining of

  9. ALICE HMPID Radiator Vessel

    CERN Document Server

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  10. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-09-01

    A technical demonstration was successfully completed of simulated reactor vessel sectioning using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in. layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel; air arc gouging was selected to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. Three sectioning operations were demonstrated. For all three, the operating parameters were the same; but the position of the sample was varied. For the first cut, the sample was placed in a horizontal position, and it was successfully severed from the SS side. For the second cut, the sample was turned over and cut from the carbon steel side. Cutting from the carbon steel side has the advantages of cost reduction

  11. Wall Turbulence.

    Science.gov (United States)

    Hanratty, Thomas J.

    1980-01-01

    This paper gives an account of research on the structure of turbulence close to a solid boundary. Included is a method to study the flow close to the wall of a pipe without interferring with it. (Author/JN)

  12. Baking results of KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. T.; Kim, Y. J.; Kim, K. M.; Im, D. S.; Joung, N. Y.; Yang, H. L.; Kim, Y. S.; Kwon, M. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The Korea Superconducting Tokamak Advanced Research (KSTAR) is an advanced superconducting tokamak designed to establish a scientific and technological basis for an attractive fusion reactor. The fusion energy in the tokamak device is released through fusion reactions of light atoms such as deuterium or helium in hot plasma state, of which temperature reaches several hundreds of millions Celsius. The high temperature plasma is created in the vacuum vessel that provides ultra high vacuum status. Accordingly, it is most important for the vacuum condition to keep clean not only inner space but also surface of the vacuum vessel to make high quality plasma. There are two methods planned to clean the wall surface of the KSTAR vacuum vessel. One is surface baking and the other is glow discharge cleaning (GDC). To bake the vacuum vessel, De-Ionized (DI) water is heated to 130 .deg. C and circulated in the passage between double walls of the vacuum vessel (VV) in order to bake the surface. The GDC operation uses hydrogen and inert gas discharges. In this paper, general configuration and brief introduction of the baking result will be reported.

  13. Baking results of KSTAR vacuum vessel

    International Nuclear Information System (INIS)

    Kim, S. T.; Kim, Y. J.; Kim, K. M.; Im, D. S.; Joung, N. Y.; Yang, H. L.; Kim, Y. S.; Kwon, M.

    2009-01-01

    The Korea Superconducting Tokamak Advanced Research (KSTAR) is an advanced superconducting tokamak designed to establish a scientific and technological basis for an attractive fusion reactor. The fusion energy in the tokamak device is released through fusion reactions of light atoms such as deuterium or helium in hot plasma state, of which temperature reaches several hundreds of millions Celsius. The high temperature plasma is created in the vacuum vessel that provides ultra high vacuum status. Accordingly, it is most important for the vacuum condition to keep clean not only inner space but also surface of the vacuum vessel to make high quality plasma. There are two methods planned to clean the wall surface of the KSTAR vacuum vessel. One is surface baking and the other is glow discharge cleaning (GDC). To bake the vacuum vessel, De-Ionized (DI) water is heated to 130 .deg. C and circulated in the passage between double walls of the vacuum vessel (VV) in order to bake the surface. The GDC operation uses hydrogen and inert gas discharges. In this paper, general configuration and brief introduction of the baking result will be reported

  14. Head spray nozzle in reactor pressure vessel

    International Nuclear Information System (INIS)

    Hatano, Shun-ichi.

    1990-01-01

    In a reactor pressure vessel of a BWR type reactor, a head spray nozzle is used for cooling the head of the pressure vessel and, in view of the thermal stresses, it is desirable that cooling is applied as uniformly as possible. A conventional head spray is constituted by combining full cone type nozzles. Since the sprayed water is flown down upon water spraying and the sprayed water in the vertical direction is overlapped, the flow rate distribution has a high sharpness to form a shape as having a maximum value near the center and it is difficult to obtain a uniform flow rate distribution in the circumferential direction. Then, in the present invention, flat nozzles each having a spray water cross section of laterally long shape, having less sharpness in the circumferential distribution upon spraying water to the inner wall of the pressure vessel and having a wide angle of water spray are combined, to make the flow rate distribution of spray water uniform in the inner wall of the pressure vessel. Accordingly, the pressure vessel can be cooled uniformly and thermal stresses upon cooling can be decreased. (N.H.)

  15. Foundamental characteristics of layered pressure vessel

    International Nuclear Information System (INIS)

    Moriwaki, Yoshikazu; Fugino, Masayuki; Shimizu, Yasuhiro; Nakamura, Takeshi

    1978-01-01

    Pressure vessels become larger and the working pressure become higher with the remarkable development of petroleum, chemical, thermal power generation and atomic energy industries. Multi-layered pressure vessels can be manufactured cheaply without large installations, and large wall thickness can be made, therefore they are suitable for large pressure vessels. The stress and deformation behaviors of such vessels are very complex because of the effect of frictional force working between layers. In this study, the phenomena arising in multiple layers and the difference as compared with single wall were studied fundamentally as one step for analyzing multi-layered pressure vessels as a whole. Finite element technique was employed as the analyzing method, and the behavior of multiple layers was analyzed, regarding it as multiple contact problem. The behavior of multiple layers seems to appear conspicuously in case of bending load, therefore the basic characteristics regarding bending were examined. The evaluation of interfacial stiffness was carried out by experiment. The computer program for analyzing multiple contact problem was developed. In order to examine the validity of the program, comparison with the analytical solution heretofore and the result of calculation by finite element technique was carried out. Moreover, the experimental proof with multi-layered models was made. The frictional force between layers hardly contributes to the stiffness. (Kako, I.)

  16. Pressure vessels for reactors made from structural steel with limited tensile strength

    International Nuclear Information System (INIS)

    Machatti, H.

    1973-01-01

    The reactor pressure vessel is prestressed in several directions with prestressing elements fabricated of steel with a high yielding point. This design allows a substantial reduction of wall thickness or an increase of the inner diameter at equal wall thickness. The prestress of the prestressing elements is designed to achieve a maximum stress release of the vessel walls at normal operating conditions and to fully utilize the maximum load of the vessel walls. For safety reasons the cross section of the prestressing elements is constructed in a way that strain is always 20 % lower the yield point. (P.K.)

  17. Navigator-gated 3D blood oxygen level-dependent CMR at 3.0-T for detection of stress-induced myocardial ischemic reactions.

    Science.gov (United States)

    Jahnke, Cosima; Gebker, Rolf; Manka, Robert; Schnackenburg, Bernhard; Fleck, Eckart; Paetsch, Ingo

    2010-04-01

    This study determined the value of navigator-gated 3-dimensional blood oxygen level-dependent (BOLD) cardiac magnetic resonance (CMR) at 3.0-T for the detection of stress-induced myocardial ischemic reactions. Although BOLD CMR has been introduced for characterization of myocardial oxygenation status, previously reported CMR approaches suffered from a low signal-to-noise ratio and motion-related artifacts with impaired image quality and a limited diagnostic value in initial patient studies. Fifty patients with suspected or known coronary artery disease underwent CMR at 3.0-T followed by invasive X-ray angiography within 48 h. Three-dimensional BOLD images were acquired during free breathing with full coverage of the left ventricle in a short-axis orientation. The BOLD imaging was performed at rest and under adenosine stress, followed by stress and rest first-pass perfusion and delayed enhancement imaging. Quantitative coronary X-ray angiography (QCA) was used for coronary stenosis definition (diameter reduction > or =50%). The BOLD and first-pass perfusion images were semiquantitatively evaluated (for BOLD imaging, signal intensity differences between stress and rest [DeltaSI]; for perfusion imaging, myocardial perfusion reserve index [MPRI]). The image quality of BOLD CMR at rest and during adenosine stress was considered good to excellent in 90% and 84% of the patients, respectively. The DeltaSI measurements differed significantly between normal myocardium, myocardium supplied by a stenotic coronary artery, and infarcted myocardium (p exogenous contrast-enhancement studies. Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Cylindrical pressure vessel constructed of several layers

    International Nuclear Information System (INIS)

    Yamauchi, Takeshi.

    1976-01-01

    For a cylindrical pressure vessel constructed of several layers whose jacket has at least one circumferential weld joining the individual layers, it is proposed to provide this at least at the first bending line turning point (counting from the weld between the jacket and vessel floor), which the sinusoidally shaped jacket has. The section of the jacket extending in between should be made as a full wall section. The proposal is based on calculations of the bending stiffness of cylindrical jackets, which could not yet be confirmed for jackets having several layers. (UWI) [de

  19. Integration of ITER in-vessel diagnostic components in the vacuum vessel

    International Nuclear Information System (INIS)

    Encheva, A.; Bertalot, L.; Macklin, B.; Vayakis, G.; Walker, C.

    2009-01-01

    The integration of ITER in-vessel diagnostic components is an important engineering activity. The positioning of the diagnostic components must correlate not only with their functional specifications but also with the design of the major parts of ITER torus, in particular the vacuum vessel, blanket modules, blanket manifolds, divertor, and port plugs, some of which are not yet finally designed. Moreover, the recently introduced Edge Localised Mode (ELM)/Vertical Stability (VS) coils mounted on the vacuum vessel inner wall call for not only more than a simple review of the engineering design settled down for several years now, but also for a change in the in-vessel distribution of the diagnostic components and their full impact has yet to be determined. Meanwhile, the procurement arrangement (a document defining roles and responsibilities of ITER Organization and Domestic Agency(s) (DAs) for each in-kind procurement including technical scope of work, quality assurance requirements, schedule, administrative matters) for the vacuum vessel must be finalized. These make the interface process even more challenging in terms of meeting the vacuum vessel (VV) procurement arrangement's deadline. The process of planning the installation of all the ITER diagnostics and integrating their installation into the ITER Integrated Project Schedule (IPS) is now underway. This paper covers the progress made recently on updating and issuing the interfaces of the in-vessel diagnostic components with the vacuum vessel, outlines the requirements for their attachment and summarises the installation sequence.

  20. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Chen Huijun

    2009-12-01

    Full Text Available Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR of the carotid vessel wall is one promising modality in the evaluation of patients with carotid atherosclerotic disease. Advances in carotid vessel wall CMR allow comprehensive assessment of morphology inside the wall, contributing substantial disease-specific information beyond luminal stenosis. Although carotid vessel wall CMR has not been widely used to screen for carotid atherosclerotic disease, many trials support its potential for this indication. This review summarizes the current state of knowledge regarding carotid vessel wall CMR and its potential clinical application for management of carotid atherosclerotic disease.

  1. Confinement Vessel Assay System: Calibration and Certification Report

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine C. [Los Alamos National Laboratory; Bourne, Mark M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Evans, Louise [Los Alamos National Laboratory; Gomez, Cipriano [Retired CMR-OPS: OPERATIONS; Mayo, Douglas R. [Los Alamos National Laboratory; Miko, David K. [Los Alamos National Laboratory; Salazar, William R. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory

    2012-07-17

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of {le} 100-g {sup 239}Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  2. Confinement Vessel Assay System: Calibration and Certification Report

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Gomez, Cipriano; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le) 100-g 239 Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  3. Problems in Pressure Vessel Design and Manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, O [Uddeholms AB, Degerfors (Sweden); Nilson, Ragnar [AB Atomenergi, Nykoeping (Sweden)

    1963-05-15

    The general desire by the power reactor process makers to increase power rating and their efforts to involve more advanced thermal behaviour and fuel handling facilities within the reactor vessels are accompanied by an increase in both pressure vessel dimensions and various difficulties in giving practical solutions of design materials and fabrication problems. In any section of this report it is emphasized that difficulties and problems already met with will meet again in the future vessels but then in modified forms and in many cases more pertinent than before. As for the increase in geometrical size it can be postulated that with use of better materials and adjusted fabrication methods the size problems can be taken proper care of. It seems likely that vessels of sufficient large diameter and height for the largest power output, which is judged as interesting in the next ten year period, can be built without developing totally new site fabrication technique. It is, however, supposed that such a fabrication technique will be feasible though at higher specific costs for the same quality requirements as obtained in shop fabrication. By the postulated use of more efficient vessel material with principally the same good features of easy fabrication in different stages such as preparation, welding, heat treatment etc as ordinary or slightly modified carbon steels the increase in wall thickness might be kept low. There exists, however, a development work to be done for low-alloy steels to prove their justified use in large reactor pressure vessels.

  4. The pressure vessel for the NSF tandem

    International Nuclear Information System (INIS)

    Jones, C.W.

    1979-04-01

    The pressure vessel is a major component of the 30 MV tandem Van de Graaff electrostatic accelerator to be used in nuclear structure research at Daresbury Laboratory. The accelerator will be capable of accelerating the full range of ions in the form of a beam. Acceleration takes place in a vertical evacuated tube (beam tube) by means of a high potential on a terminal at the central position, the terminal and beam tube assembly being supported by an insulated stack structure within the pressure vessel. Under operating conditions the vessel is filled with sulphur hexafluoride gas (SF 6 ) at high pressure which acts as an insulating medium between the centre terminal and the vessel wall. The vessel is situated inside a concrete tower which besides supporting the injector room above the vessel also acts as radiation shielding around the accelerator. The report covers: functional requirements; fundamental considerations with regard to the design and procurement; detail design; materials; manufacture; acceptance test; surface treatment; final leak test. (U.K.)

  5. Crack propagation on spherical pressure vessels

    International Nuclear Information System (INIS)

    Lebey, J.; Roche, R.

    1975-01-01

    The risk presented by a crack on a pressure vessel built with a ductile steel cannot be well evaluated by simple application of the rules of Linear Elastic Fracture Mechanics, which only apply to brittle materials. Tests were carried out on spherical vessels of three different scales built with the same steel. Cracks of different length were machined through the vessel wall. From the results obtained, crack initiation stress (beginning of stable propagation) and instable propagation stress may be plotted against the lengths of these cracks. For small and medium size, subject to ductile fracture, the resulting curves are identical, and may be used for ductile fracture prediction. Brittle rupture was observed on larger vessels and crack propagation occurred at lower stress level. Preceedings curves are not usable for fracture analysis. Ultimate pressure can be computed with a good accuracy by using equivalent energy toughness, Ksub(1cd), characteristic of the metal plates. Satisfactory measurements have been obtained on thin samples. The risks of brittle fracture may then judged by comparing Ksub(1cd) with the calculated K 1 value, in which corrections for vessel shape are taken into account. It is thus possible to establish the bursting pressure of cracked spherical vessels, with the help of two rules, one for brittle fracture, the other for ductile instability. A practical method is proposed on the basis of the work reported here

  6. Problems in Pressure Vessel Design and Manufacture

    International Nuclear Information System (INIS)

    Hellstroem, O.; Nilson, Ragnar

    1963-05-01

    The general desire by the power reactor process makers to increase power rating and their efforts to involve more advanced thermal behaviour and fuel handling facilities within the reactor vessels are accompanied by an increase in both pressure vessel dimensions and various difficulties in giving practical solutions of design materials and fabrication problems. In any section of this report it is emphasized that difficulties and problems already met with will meet again in the future vessels but then in modified forms and in many cases more pertinent than before. As for the increase in geometrical size it can be postulated that with use of better materials and adjusted fabrication methods the size problems can be taken proper care of. It seems likely that vessels of sufficient large diameter and height for the largest power output, which is judged as interesting in the next ten year period, can be built without developing totally new site fabrication technique. It is, however, supposed that such a fabrication technique will be feasible though at higher specific costs for the same quality requirements as obtained in shop fabrication. By the postulated use of more efficient vessel material with principally the same good features of easy fabrication in different stages such as preparation, welding, heat treatment etc as ordinary or slightly modified carbon steels the increase in wall thickness might be kept low. There exists, however, a development work to be done for low-alloy steels to prove their justified use in large reactor pressure vessels

  7. Comparison of {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG PET) and cardiac magnetic resonance (CMR) in corticosteroid-naive patients with conduction system disease due to cardiac sarcoidosis

    Energy Technology Data Exchange (ETDEWEB)

    Ohira, Hiroshi; Birnie, David H.; Mc Ardle, Brian; Dick, Alexander; Klein, Ran; Renaud, Jennifer; DeKemp, Robert A.; Davies, Ross; Hessian, Renee; Liu, Peter; Nery, Pablo B. [University of Ottawa Heart Institute, Molecular Function and Imaging Program, National Cardiac PET Centre, Ottawa, ON (Canada); University of Ottawa Heart Institute, Arrhythmia Service, Division of Cardiology, Department of Medicine, Ottawa, ON (Canada); Pena, Elena; Dennie, Carole [The Ottawa Hospital, Medical Imaging Department, Ottawa, ON (Canada); University of Ottawa, Department of Radiology, Ottawa, ON (Canada); Bernick, Jordan; Wells, George A. [University of Ottawa Heart Institute, Cardiovascular Research Methods Center, Ottawa, ON (Canada); Leung, Eugene [The Ottawa Hospital, Division of Nuclear Medicine, Department of Medicine, Ottawa, Ontario (Canada); Yoshinaga, Keiichiro [Hokkaido University School of Medicine, Department of Molecular Imaging, Hokkaido (Japan); Tsujino, Ichizo; Sato, Takahiro; Nishimura, Masaharu [Hokkaido University School of Medicine, First Department of Medicine, Hokkaido (Japan); Manabe, Osamu; Tamaki, Nagara [Hokkaido University School of Medicine, Department of Nuclear Medicine, Hokkaido (Japan); Oyama-Manabe, Noriko [Hokkaido University Hospital, Diagnostic and Interventional Radiology, Hokkaido (Japan); Ruddy, Terrence D.; Beanlands, Rob S.B. [University of Ottawa Heart Institute, Molecular Function and Imaging Program, National Cardiac PET Centre, Ottawa, ON (Canada); University of Ottawa Heart Institute, Arrhythmia Service, Division of Cardiology, Department of Medicine, Ottawa, ON (Canada); The Ottawa Hospital, Medical Imaging Department, Ottawa, ON (Canada); University of Ottawa, Department of Radiology, Ottawa, ON (Canada); The Ottawa Hospital, Division of Nuclear Medicine, Department of Medicine, Ottawa, Ontario (Canada); Chow, Benjamin J.W. [University of Ottawa Heart Institute, Molecular Function and Imaging Program, National Cardiac PET Centre, Ottawa, ON (Canada); University of Ottawa Heart Institute, Arrhythmia Service, Division of Cardiology, Department of Medicine, Ottawa, ON (Canada); The Ottawa Hospital, Medical Imaging Department, Ottawa, ON (Canada); University of Ottawa, Department of Radiology, Ottawa, ON (Canada)

    2016-02-15

    Cardiac sarcoidosis (CS) is a cause of conduction system disease (CSD). {sup 18}F-Fluorodeoxyglucose-positron emission tomography (FDG PET) and cardiac magnetic resonance (CMR) are used for detection of CS. The relative diagnostic value of these has not been well studied. The aim was to compare these imaging modalities in this population. We recruited steroid-naive patients with newly diagnosed CSD due to CS. All CS patients underwent both imaging studies within 12 weeks of each other. Patients were classified into two groups: group A with chronic mild CSD (right bundle branch block and/or axis deviation), and group B with new-onset atrioventricular block (AVB, Mobitz type II or third-degree AVB). Thirty patients were included. Positive findings on both imaging studies were seen in 72 % of patients (13/18) in group A and in 58 % of patients (7/12) in group B. The remainder (28 %) of the patients in group A were positive only on CMR. Of the patients in group B, 8 % were positive only on CMR and 33 % were positive only on FDG PET. Patients in group A were more likely to be positive only on CMR, and patients in group B were more likely to be positive only on FDG PET (p = 0.02). Patients in group B positive only on FDG PET underwent CMR earlier relative to their symptomatology than patients positive only on CMR (median 7.0, IQR 1.5 - 34.3, vs. 72.0, IQR 25.0 - 79.5 days; p = 0.03). The number of positive FDG PET and CMR studies was different in patients with CSD depending on their clinical presentation. This study demonstrated that CMR can adequately detect cardiac involvement associated with chronic mild CSD. In patients presenting with new-onset AVB and a negative CMR study, FDG PET may be useful for detecting cardiac involvement due to CS. (orig.)

  8. A water inner circulation device for a reactor vessel

    International Nuclear Information System (INIS)

    Eriksson, O.

    1976-01-01

    A water inner circulation device for a reactor vessel comprising a pump mounted in the reactor vessel and driven by a water-cooled electric motor mounted in a housing outside the reactor vessel, the shaft of the pump passing through the reactor-vessel bottom and being coupled to the motor shaft in a member mechanically connected to the bottom of the reactor vessel in the vicinity of the motor housing, the pump shaft being surrounded by a resilient sealing ring, the reactor vessel communicating with the cooling channels of the pump, when the latter is operating, via a slot surrounding the pump hollow cylindrical shaft, characterized in that the slot inner end is used for/forming a circular space surrounding the pump shaft and surrounded by the motorhousing, in which is coaxially mounted a separating cylindral wall, the upper edge of which is tightly applied against the inner wall of the motor-housing to which it is fastened vertically, the inner surface of said wall being turned towards the outer surface of a circular packing-box, the outer surface of said separating wall constituting a separating radical inner surface for a circular chamber through which flow the motor cooling water. (author)

  9. Vacuum vessel for a nuclear fusion device

    International Nuclear Information System (INIS)

    Watanabe, Takashi; Sato, Hiroshi; Owada, Koro.

    1976-01-01

    Object: To provide a reinforcing member on a bellows portion to reduce a stress at the bellows portion thereby increasing the strength of a vessel. Structure: A vacuum vessel for a nuclear fusion device has a bellows portion and a wall thick portion. A support extended toward the bellows portion is secured inside of a toroidal section in order to reduce the stress at the bellows portion. An insulator is interposed between the support and the bellows portion and is retained on the support by a bolt. Since the stress may be reduced by the support, the wall thick of the bellows portion may be decreased to sufficiently secure the low electric resistance value. (Yoshihara, H.)

  10. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  11. Tumor Blood Vessel Dynamics

    Science.gov (United States)

    Munn, Lance

    2009-11-01

    ``Normalization'' of tumor blood vessels has shown promise to improve the efficacy of chemotherapeutics. In theory, anti-angiogenic drugs targeting endothelial VEGF signaling can improve vessel network structure and function, enhancing the transport of subsequent cytotoxic drugs to cancer cells. In practice, the effects are unpredictable, with varying levels of success. The predominant effects of anti-VEGF therapies are decreased vessel leakiness (hydraulic conductivity), decreased vessel diameters and pruning of the immature vessel network. It is thought that each of these can influence perfusion of the vessel network, inducing flow in regions that were previously sluggish or stagnant. Unfortunately, when anti-VEGF therapies affect vessel structure and function, the changes are dynamic and overlapping in time, and it has been difficult to identify a consistent and predictable normalization ``window'' during which perfusion and subsequent drug delivery is optimal. This is largely due to the non-linearity in the system, and the inability to distinguish the effects of decreased vessel leakiness from those due to network structural changes in clinical trials or animal studies. We have developed a mathematical model to calculate blood flow in complex tumor networks imaged by two-photon microscopy. The model incorporates the necessary and sufficient components for addressing the problem of normalization of tumor vasculature: i) lattice-Boltzmann calculations of the full flow field within the vasculature and within the tissue, ii) diffusion and convection of soluble species such as oxygen or drugs within vessels and the tissue domain, iii) distinct and spatially-resolved vessel hydraulic conductivities and permeabilities for each species, iv) erythrocyte particles advecting in the flow and delivering oxygen with real oxygen release kinetics, v) shear stress-mediated vascular remodeling. This model, guided by multi-parameter intravital imaging of tumor vessel structure

  12. Maury Journals - German Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — German vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  13. Expanding plasma jet in a vacuum vessel

    International Nuclear Information System (INIS)

    Chutov, Yu.I.; Kravchenko, A.Yu.; Yakovetskij, V.S.

    1998-01-01

    The paper deals with numerical calculations of parameters of a supersonic quasi-neutral argon plasma jet expanding into a cylindrical vacuum vessel and interacting with its inner surface. A modified method of large particles was used, the complex set of hydrodynamic equations being broken into simpler components, each of which describes a separate physical process. Spatial distributions of the main parameters of the argon plasma jet were simulated at various times after the jet entering the vacuum vessel, the parameters being the jet velocity field, the full plasma pressure, the electron temperature, the temperature of heavy particles, and the degree of ionization. The results show a significant effect of plasma jet interaction on the plasma parameters. The jet interaction with the vessel walls may result e.g. in excitation of shock waves and rotational plasma motions. (J.U.)

  14. PWR pressure vessel integrity during overcooling accidents

    International Nuclear Information System (INIS)

    Cheverton, R.D.

    1981-01-01

    Pressurized water reactors are susceptible to certain types of hypothetical accidents that under some circumstances, including operation of the reactor beyond a critical time in its life, could result in failure of the pressure vessel as a result of propagation of crack-like defects in the vessel wall. The accidents of concern are those that result in thermal shock to the vessel while the vessel is subjected to internal pressure. Such accidents, referred to as pressurized thermal shock or overcooling accidents (OCA), include a steamline break, small-break LOCA, turbine trip followed by stuck-open bypass valves, the 1978 Rancho Seco and the TMI accidents and many other postulated and actual accidents. The source of cold water for the thermal shock is either emergency core coolant or the normal primary-system coolant. ORNL performed fracture-mechanics calculations for a steamline break in 1978 and for a turbine-trip case in 1980 and concluded on the basis of the results that many more such calculations would be required. To meet the expected demand in a realistic way a computer code, OCA-I, was developed that accepts primary-system temperature and pressure transients as input and then performs one-dimensional thermal and stress analyses for the wall and a corresponding fracture-mechanics analysis for a long axial flaw. The code is briefly described, and its use in both generic and specific plant analyses is discussed

  15. Thickness dependent properties of CMR Manganite thin films on lattice mismatched substrates: Distinguishing Strain and Interface Effects

    Science.gov (United States)

    Davidson, Anthony, III; Kolagani, Rajeswari; Bacharova, Ellisaveta; Yong, Grace; Smolyaninova, Vera; Schaefer, David; Mundle, Rajeh

    2007-03-01

    Epitaxial thin films of CMR manganite materials have been known to show thickness dependent electrical and magnetic properties on lattice mismatched substrates. Below a critical thickness, insulator-metal transition is suppressed. These effects have been largely attributed to the role of bi-axial lattice mismatch strain. Our recent results of epitaxial thin films of La0.67Ca0.33MnO3 (LCMO) on two substrates with varying degrees of compressive lattice mismatch indicate that, in addition to the effect of lattice mismatch strain, the thickness dependence of the properties are influenced by other factors possibly related to the nature of the film substrate interface and defects such as twin boundaries. We have compared the properties of LCMO films on (100) oriented LaAlO3 and (001) oriented NdCaAlO4 both of which induce compressive bi-axial strain. Interestingly, the suppression of the insulator-metal transition is less in films on NCAO which has a larger lattice mismatch. We will present results correlating the electrical and magneto transport properties with the structure and morphology of the films.

  16. RV Fractional Area Change and TAPSE as Predictors of Severe Right Ventricular Dysfunction in Pulmonary Hypertension: A CMR Study.

    Science.gov (United States)

    Hoette, Susana; Creuzé, Nicolas; Günther, Sven; Montani, David; Savale, Laurent; Jaïs, Xavier; Parent, Florence; Sitbon, Olivier; Rochitte, Carlos Eduardo; Simonneau, Gerald; Humbert, Marc; Souza, Rogerio; Chemla, Denis

    2018-04-01

    The right ventricular ejection fraction (RVEF) is a surrogate marker of right ventricular function in pulmonary hypertension (PH), but its measurement is complicated and time consuming. The tricuspid annular plane systolic excursion (TAPSE) measures only the longitudinal component of RV contraction while the right ventricular fractional area change (RVFAC) takes into account both the longitudinal and the transversal components. The aim of our study was to evaluate the relationship between RVEF, RVFAC, and TAPSE according to hemodynamic severity in two groups of patients with PH: pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH). Fifty-four patients with PAH (n = 15) and CTEPH (n = 39) underwent right heart catheterization and cardiac magnetic resonance (CMR). The ventricular volumes and areas, TAPSE, and eccentricity index were measured. The RVFAC was more strongly correlated with the RVEF (r = 0.81, p good index to estimate RVEF in PH patients; even better than the TAPSE in patients with more severe hemodynamic profile, possibly for including the transversal component of right ventricular function in its measurement. Furthermore, RVFAC performance was similar in the two PH groups (PAH and CTEPH).

  17. Coronary artery anomalies. Diagnosis and classification based on cardiac CT and MRI (CMR) - from ALCAPA to anomalies of termination

    International Nuclear Information System (INIS)

    Heermann, Philipp; Heindel, Walter; Schuelke, Christoph

    2017-01-01

    Coronary artery anomalies encompass a clinically and anatomically variable spectrum including physiological variants and pathophysiologically relevant anomalies. The majority of the variants has no hemodynamic relevance and is often detected accidentally. The recognition of the rare and relevant anomalies that cause either relevant shunt volumes leading to myocardial ischemia or ventricular tachyarrhythmias with the risk of sudden cardiac death is of major importance. This review is based on a literature search in PubMed conducted using the key words ''coronary artery'' and/or ''anomaly'' and/or ''anomalous origin'' and/or ''myocardial bridging'' and/or ''coronary artery fistula'' and/or ''Bland-White-Garland'' and/or ''ALCAPA''. Coronary artery anomalies can be anatomically subdivided into anomalies of origin, course and termination. The method of choice for anatomical imaging is ECG-triggered or gated multislice CT (MSCT) that provides high spatial resolution and the capability of multiplanar reconstructions. It facilitates the delineation of the precise course of all three coronary arteries and thus allows for correct classification in the anatomical classification system of coronary artery anomalies. The strengths of cardiac magnetic resonance imaging (CMR) are the evaluation of cardiac morphology, myocardial tissue properties and myocardial function. Basic methods are the analysis of myocardial contraction and perfusion with and without pharmacologic stress. Furthermore, potential shunt volumes could be quantified by phase contrast imaging or volumetry.

  18. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W. Sr.

    1992-01-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system use relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, Monte Carlo calculations were performed using the code Electron Gamma Shower (EGS4). Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessel sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was or cross fire between blood vessels was assumed. Results are useful in assessing the doses to blood and blood vessel walls for different nuclear medicine procedures

  19. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W.

    1991-05-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system used relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, EGS4 Monte Carlo calculations were performed. Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessels sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was assumed nor cross fire between vessel was assumed. Results are useful in assessing the dose in blood and blood vessel walls for different nuclear medicine procedures. 6 refs., 6 figs., 5 tabs

  20. Quench of molten aluminum oxide associated with in-vessel debris retention by RPV internal water

    International Nuclear Information System (INIS)

    Maruyama, Yu; Yamano, Norihiro; Moriyama, Kiyofumi; Park, Hyun Sun; Kudo, Tamotsu; Yang, Yanhua; Sugimoto, Jun

    1999-01-01

    In-vessel debris coolability experiments were performed in ALPHA program at JAERI. Molten aluminum oxide (Al 2 O 3 ) was poured into a pool of water in a lower head experimental vessel. Post-test observation and measurement using an ultrasonic technique indicated the formation of the interfacial gap between the solidified Al 2 O 3 and the vessel wall. Thermal responses of the vessel wall implied that the interfacial gap acted initially as a thermal resistance and water subsequently penetrated into the interfacial gap. The maximum heat flux at the inner surface of the vessel facing to the solidified Al 2 O 3 was roughly evaluated to be ranged from 320 kW/m 2 to 600 kW/m 2 . A post-test analysis was conducted with CAMP code. The influence of the interfacial gap on thermal behavior of Al 2 O 3 and the vessel wall was examined. (authors)

  1. TPX vacuum vessel transient thermal and stress conditions

    International Nuclear Information System (INIS)

    Feldshteyn, Y.; Dinkevich, S.; Feng, T.; Majumder, D.

    1995-01-01

    The TPX vacuum vessel provides the vacuum boundary for the plasma and the mechanical support for the internal components. Another function of the vacuum vessel is to contain neutron shielding water in the double wall space during normal operation. This double wall space serves as a heat reservoir for the entire vacuum vessel during bakeout. The vacuum vessel and the internal components are subjected to thermal stresses induced by a nonuniform temperature distribution within the structure during bakeout. A successful Conceptual Design Review in March 1993 has established superheated steam as the heating source of the vacuum vessel. A transient bakeout mode of the vacuum vessel and in-vessel components has been analyzed to evaluate transient period duration, proper temperature level, actual thermal stresses and performance of the steam equipment. Thermally, the vacuum vessel structure may be considered as an adiabatic system because it is perfectly insulated by the strong surrounding vacuum and multiple layers of superinsulation. Important aspects of the analysis are described herein

  2. Myocardial Fibrosis in Competitive Triathletes Detected by Contrast-Enhanced CMR Correlates With Exercise-Induced Hypertension and Competition History.

    Science.gov (United States)

    Tahir, Enver; Starekova, Jitka; Muellerleile, Kai; von Stritzky, Alexandra; Münch, Julia; Avanesov, Maxim; Weinrich, Julius M; Stehning, Christian; Bohnen, Sebastian; Radunski, Ulf K; Freiwald, Eric; Blankenberg, Stefan; Adam, Gerhard; Pressler, Axel; Patten, Monica; Lund, Gunnar K

    2017-12-08

    This study analyzed the presence of myocardial fibrosis detected by late gadolinium-enhancement (LGE) cardiac magnetic resonance (CMR) in correlation with the performance of competitive triathletes objectified by an exercise test and individual competition history. Myocardial fibrosis detected by LGE CMR has been reported to occur in 0% to 50% of asymptomatic athletes. However, the cause and mechanisms of myocardial fibrosis are unclear. Eighty-three asymptomatic triathletes undergoing >10 training h per week (43 ± 10 years of age; 65% male) and 36 sedentary controls were studied by using LGE and extracellular volume (ECV) CMR. Parameters of physical fitness were measured by spiroergometry. Triathletes reported their lifetime competition results. LGE CMR revealed focal nonischemic myocardial fibrosis in 9 of 54 (17%) male triathletes (LGE + ) but in none of the female triathletes (p pressure (213 ± 24 mm Hg) than LGE - triathletes (194 ± 26 mm Hg; p 1,880 km completed during competition had the highest accuracy to predict LGE, with an area under the curve value of 0.876 (p pressure (p < 0.05) and the swimming race distance (p < 0.01) as independent predictors of LGE presence. Myocardial fibrosis in asymptomatic triathletes seems to be associated with exercise-induced hypertension and the race distances. There appears to be a safe upper limit, beyond which exercise may result in myocardial fibrosis. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  4. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  5. Progress of ITER vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, K., E-mail: Kimihiro.Ioki@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Bayon, A. [F4E, c/ Josep Pla, No. 2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain); Choi, C.H.; Daly, E.; Dani, S.; Davis, J.; Giraud, B.; Gribov, Y.; Hamlyn-Harris, C.; Jun, C.; Levesy, B. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Kim, B.C. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Kuzmin, E. [NTC “Sintez”, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Le Barbier, R.; Martinez, J.-M. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Pathak, H. [ITER-India, A-29, GIDC Electronic Estate, Sector 25, Gandhinagar 382025 (India); Preble, J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Sa, J.W. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Terasawa, A.; Utin, Yu. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); and others

    2013-10-15

    Highlights: ► This covers the overall status and progress of the ITER vacuum vessel activities. ► It includes design, R and D, manufacturing and approval process of the regulators. ► The baseline design was completed and now manufacturing designs are on-going. ► R and D includes ISI, dynamic test of keys and lip-seal welding/cutting technology. ► The VV suppliers produced full-scale mock-ups and started VV manufacturing. -- Abstract: Design modifications were implemented in the vacuum vessel (VV) baseline design in 2011–2012 for finalization. The modifications are mostly due to interface components, such as support rails and feedthroughs for the in-vessel coils (IVC). Manufacturing designs are being developed at the domestic agencies (DAs) based on the baseline design. The VV support design was also finalized and tests on scale mock-ups are under preparation. Design of the in-wall shielding (IWS) has progressed, considering the assembly methods and the required tolerances. Further modifications are required to be consistent with the DAs’ manufacturing designs. Dynamic tests on the inter-modular and stub keys to support the blanket modules are being performed to measure the dynamic amplification factor (DAF). An in-service inspection (ISI) plan has been developed and R and D was launched for ISI. Conceptual design of the VV instrumentation has been developed. The VV baseline design was approved by the agreed notified body (ANB) in accordance with the French Nuclear Pressure Equipment Order procedure.

  6. Progress of ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Bayon, A.; Choi, C.H.; Daly, E.; Dani, S.; Davis, J.; Giraud, B.; Gribov, Y.; Hamlyn-Harris, C.; Jun, C.; Levesy, B.; Kim, B.C.; Kuzmin, E.; Le Barbier, R.; Martinez, J.-M.; Pathak, H.; Preble, J.; Sa, J.W.; Terasawa, A.; Utin, Yu.

    2013-01-01

    Highlights: ► This covers the overall status and progress of the ITER vacuum vessel activities. ► It includes design, R and D, manufacturing and approval process of the regulators. ► The baseline design was completed and now manufacturing designs are on-going. ► R and D includes ISI, dynamic test of keys and lip-seal welding/cutting technology. ► The VV suppliers produced full-scale mock-ups and started VV manufacturing. -- Abstract: Design modifications were implemented in the vacuum vessel (VV) baseline design in 2011–2012 for finalization. The modifications are mostly due to interface components, such as support rails and feedthroughs for the in-vessel coils (IVC). Manufacturing designs are being developed at the domestic agencies (DAs) based on the baseline design. The VV support design was also finalized and tests on scale mock-ups are under preparation. Design of the in-wall shielding (IWS) has progressed, considering the assembly methods and the required tolerances. Further modifications are required to be consistent with the DAs’ manufacturing designs. Dynamic tests on the inter-modular and stub keys to support the blanket modules are being performed to measure the dynamic amplification factor (DAF). An in-service inspection (ISI) plan has been developed and R and D was launched for ISI. Conceptual design of the VV instrumentation has been developed. The VV baseline design was approved by the agreed notified body (ANB) in accordance with the French Nuclear Pressure Equipment Order procedure

  7. Integrated conjugate heat transfer analysis method for in-vessel retention with external reactor vessel cooling - 15477

    International Nuclear Information System (INIS)

    Park, J.W.; Bae, J.H.; Seol, W.C.

    2015-01-01

    An integrated conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue. The method calculates steady-state 3-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel 3-layered stratified corium (metallic pool, oxide pool and heavy metal) and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel. The 3-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method and ex-vessel boiling regimes are parametrically considered. The thermal integrity of a reactor vessel is addressed in terms of un-molten thickness profile. The vessel 3-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate inside the oxide pool and the 3-dimensional vessel heat transfer provides a much larger minimum vessel wall thickness. (authors)

  8. Method of detecting construction faults in concrete pressure vessels

    International Nuclear Information System (INIS)

    Robertson, S.A.; Duhoux, M.; Dawance, G.; Carrie, C.; Morel, D.

    1976-01-01

    A major problem in the design and construction of concrete pressure vessels for nuclear power stations is the risk of excessive air leaks through the concrete itself, due to faulty construction. The 'sonic coring' method of non-destructive concrete testing has been used successfully in pile and diaphragm wall construction control for several years, and the potential use of this method to control the presence of faults in concrete pressure vessels is here described. (author)

  9. Cholinergic innervation of human mesenteric lymphatic vessels.

    Science.gov (United States)

    D'Andrea, V; Bianchi, E; Taurone, S; Mignini, F; Cavallotti, C; Artico, M

    2013-11-01

    The cholinergic neurotransmission within the human mesenteric lymphatic vessels has been poorly studied. Therefore, our aim is to analyse the cholinergic nerve fibres of lymphatic vessels using the traditional enzymatic techniques of staining, plus the biochemical modifications of acetylcholinesterase (AChE) activity. Specimens obtained from human mesenteric lymphatic vessels were subjected to the following experimental procedures: 1) drawing, cutting and staining of tissues; 2) staining of total nerve fibres; 3) enzymatic staining of cholinergic nerve fibres; 4) homogenisation of tissues; 5) biochemical amount of proteins; 6) biochemical amount of AChE activity; 6) quantitative analysis of images; 7) statistical analysis of data. The mesenteric lymphatic vessels show many AChE positive nerve fibres around their wall with an almost plexiform distribution. The incubation time was performed at 1 h (partial activity) and 6 h (total activity). Moreover, biochemical dosage of the same enzymatic activity confirms the results obtained with morphological methods. The homogenates of the studied tissues contain strong AChE activity. In our study, the lymphatic vessels appeared to contain few cholinergic nerve fibres. Therefore, it is expected that perivascular nerve stimulation stimulates cholinergic nerves innervating the mesenteric arteries to release the neurotransmitter AChE, which activates muscarinic or nicotinic receptors to modulate adrenergic neurotransmission. These results strongly suggest, that perivascular cholinergic nerves have little or no effect on the adrenergic nerve function in mesenteric arteries. The cholinergic nerves innervating mesenteric arteries do not mediate direct vascular responses.

  10. Radon diffusion in polymer vessels using CR-39 solid state nuclear track detector

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Andre Cavalcanti; Menezes, Maria Angela de B.C.; Rocha, Zildete; Pereira, Marcio Tadeu, E-mail: andreccarneiro@gmail.com, E-mail: menezes@cdtn.br, E-mail: zildete@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Santos, Talita de Oliveira; Lara, Evelise Gomes; Braga, Mario Roberto Martins S.S., E-mail: mariomartins@gmail.com, E-mail: evelise.lara@gmail.com, E-mail: talitaolsantos@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2015-07-01

    At CDTN/CNEN, the method to determine {sup 226}Ra in several matrices by gamma spectrometry is already established; however, the method should be improved. This paper is about the first step of this improvement. Several polymer vessels were studied verifying the effect of radiolysis on the walls of the vessel. A test about the diffusion of {sup 222}Rn through the walls was carried out using the CR-39 solid state nuclear track detector. The results pointed out that the vessel made up by acrylic material is the best candidate to replace the vessel actually used. (author)

  11. The Combined Effects of Stress Concentration and Tensile Stresses from Autofrettage on the Life of Pressure Vessels

    Science.gov (United States)

    2017-02-01

    Approved for public release; distribution is unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT Thick walled pressure vessels are often...studies which will identify the cause of the reduced lives and propose corrective action. 15. SUBJECT TERMS Thick Walled Pressure Vessels...are indicated, follow agency authorization procedures, e.g. RD/FRD, PROPIN, ITAR, etc. Include copyright information. 13. SUPPLEMENTARY NOTES

  12. Continuum mathematical modelling of pathological growth of blood vessels

    Science.gov (United States)

    Stadnik, N. E.; Dats, E. P.

    2018-04-01

    The present study is devoted to the mathematical modelling of a human blood vessel pathological growth. The vessels are simulated as the thin-walled circular tube. The boundary value problem of the surface growth of an elastic thin-walled cylinder is solved. The analytical solution is obtained in terms of velocities of stress strain state parameters. The condition of thinness allows us to study finite displacements of cylinder surfaces by means of infinitesimal deformations. The stress-strain state characteristics, which depend on the mechanical parameters of the biological processes, are numerically computed and graphically analysed.

  13. Vessel discoloration detection in malarial retinopathy

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Barriga, S.; Soliz, P.; MacCormick, I.; Taylor, T.; Harding, S.; Lewallen, S.; Joshi, V.

    2016-03-01

    Cerebral malaria (CM) is a life-threatening clinical syndrome associated with malarial infection. It affects approximately 200 million people, mostly sub-Saharan African children under five years of age. Malarial retinopathy (MR) is a condition in which lesions such as whitening and vessel discoloration that are highly specific to CM appear in the retina. Other unrelated diseases can present with symptoms similar to CM, therefore the exact nature of the clinical symptoms must be ascertained in order to avoid misdiagnosis, which can lead to inappropriate treatment and, potentially, death. In this paper we outline the first system to detect the presence of discolored vessels associated with MR as a means to improve the CM diagnosis. We modified and improved our previous vessel segmentation algorithm by incorporating the `a' channel of the CIELab color space and noise reduction. We then divided the segmented vasculature into vessel segments and extracted features at the wall and in the centerline of the segment. Finally, we used a regression classifier to sort the segments into discolored and not-discolored vessel classes. By counting the abnormal vessel segments in each image, we were able to divide the analyzed images into two groups: normal and presence of vessel discoloration due to MR. We achieved an accuracy of 85% with sensitivity of 94% and specificity of 67%. In clinical practice, this algorithm would be combined with other MR retinal pathology detection algorithms. Therefore, a high specificity can be achieved. By choosing a different operating point in the ROC curve, our system achieved sensitivity of 67% with specificity of 100%.

  14. Quality assurance in thick-walled weldments

    International Nuclear Information System (INIS)

    Straub, H.

    1978-01-01

    Some guidelines are given here for judging the magnitude of flaws in welded thick-walled components (such as nuclear reactor vessels). The actually critical defect sizes are analysed, taking into account the residual stresses after welding and after annealing also. Various procedures for repairing such work are then indicated. (Auth.)

  15. Appearance of microvascular obstruction on high resolution first-pass perfusion, early and late gadolinium enhancement CMR in patients with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Redwood Simon

    2009-08-01

    Full Text Available Abstract Background The presence and extent of microvascular obstruction (MO after acute myocardial infarction can be measured by first-pass gadolinium-enhanced perfusion cardiovascular magnetic resonance (CMR or after gadolinium injection with early or late enhancement (EGE/LGE imaging. The volume of MO measured by these three methods may differ because contrast agent diffusion into the MO reduces its apparent extent over time. Theoretically, first-pass perfusion CMR should be the most accurate method to measure MO, but this technique has been limited by lower spatial resolution than EGE and LGE as well as incomplete cardiac coverage. These limitations of perfusion CMR can be overcome using spatio-temporal undersampling methods. The purpose of this study was to compare the extent of MO by high resolution first-pass k-t SENSE accelerated perfusion, EGE and LGE. Methods 34 patients with acute ST elevation myocardial infarction, treated successfully with primary percutaneous coronary intervention (PPCI, underwent CMR within 72 hours of admission. k-t SENSE accelerated first-pass perfusion MR (7 fold acceleration, spatial resolution 1.5 mm × 1.5 mm × 10 mm, 8 slices acquired over 2 RR intervals, 0.1 mmol/kg Gd-DTPA, EGE (1–4 minutes after injection with a fixed TI of 440 ms and LGE images (10–12 minutes after injection, TI determined by a Look-Locker scout were acquired. MO volume was determined for each technique by manual planimetry and summation of discs methodology. Results k-t SENSE first-pass perfusion detected more cases of MO than EGE and LGE (22 vs. 20 vs. 14, respectively. The extent of MO imaged by first-pass perfusion (median mass 4.7 g, IQR 6.7 was greater than by EGE (median mass 2.3 g, IQR 7.1, p = 0.002 and LGE (median mass 0.2 g, IQR 2.4, p = 0.0003. The correlation coefficient between MO mass measured by first-pass perfusion and EGE was 0.91 (p Conclusion The extent of MO following acute myocardial infarction appears larger on

  16. NCSX Vacuum Vessel Fabrication

    International Nuclear Information System (INIS)

    Viola ME; Brown T; Heitzenroeder P; Malinowski F; Reiersen W; Sutton L; Goranson P; Nelson B; Cole M; Manuel M; McCorkle D.

    2005-01-01

    The National Compact Stellarator Experiment (NCSX) is being constructed at the Princeton Plasma Physics Laboratory (PPPL) in conjunction with the Oak Ridge National Laboratory (ORNL). The goal of this experiment is to develop a device which has the steady state properties of a traditional stellarator along with the high performance characteristics of a tokamak. A key element of this device is its highly shaped Inconel 625 vacuum vessel. This paper describes the manufacturing of the vessel. The vessel is being fabricated by Major Tool and Machine, Inc. (MTM) in three identical 120 o vessel segments, corresponding to the three NCSX field periods, in order to accommodate assembly of the device. The port extensions are welded on, leak checked, cut off within 1-inch of the vessel surface at MTM and then reattached at PPPL, to accommodate assembly of the close-fitting modular coils that surround the vessel. The 120 o vessel segments are formed by welding two 60 o segments together. Each 60 o segment is fabricated by welding ten press-formed panels together over a collapsible welding fixture which is needed to precisely position the panels. The vessel is joined at assembly by welding via custom machined 8-inch (20.3 cm) wide spacer ''spool pieces''. The vessel must have a total leak rate less than 5 X 10 -6 t-l/s, magnetic permeability less than 1.02(micro), and its contours must be within 0.188-inch (4.76 mm). It is scheduled for completion in January 2006

  17. Pulse wave velocity as a diagnostic index: The effect of wall thickness

    Science.gov (United States)

    Hodis, Simona

    2018-06-01

    Vascular compliance is a major determinant of wave propagation within the vascular system, and hence the measurement of pulse wave velocity (PWV) is commonly used clinically as a method of detecting vascular stiffening. The accuracy of that assessment is important because vascular stiffening is a major risk factor for hypertension. PWV is usually measured by timing a pressure wave as it travels from the carotid artery to the femoral or radial artery and estimating the distance that it traveled in each case to obtain the required velocity. A major assumption on which this technique is based is that the vessel wall thickness h is negligibly small compared with the vessel radius a . The extent to which this assumption is satisfied in the cardiovascular system is not known because the ratio h /a varies widely across different regions of the vascular tree and under different pathological conditions. Using the PWV as a diagnostic test without knowing the effect of wall thickness on the measurement could lead to error when interpreting the PWV value as an index of vessel wall compliance. The aim of the present study was to extend the validity of the current practice of assessing wall stiffness by developing a method of analysis that goes beyond the assumption of a thin wall. We analyzed PWVs calculated with different wall models, depending on the ratio of wall thickness to vessel radius and the results showed that PWV is not reliable when it is estimated with the classic thin wall theory if the vessel wall is not around 25% of vessel radius. If the arterial wall is thicker than 25% of vessel radius, then the wave velocity calculated with the thin wall theory could be overestimated and in the clinical setting, this could lead to a false positive. For thicker walls, a thick wall model presented here should be considered to account for the stresses within the wall thickness that become dominant compared with the wall inertia.

  18. Radioactive waste processing vessel

    International Nuclear Information System (INIS)

    Hayashi, Masaru; Suzuki, Osamu; Ishizaki, Kanjiro.

    1987-01-01

    Purpose: To obtain a vessel of a reduced weight and with no external leaching of radioactive materials. Constitution: The vessel main body is constituted, for example, with light weight concretes or foamed concretes, particularly, foamed concretes containing fine closed bubbles in the inside. Then, layers having dense texture made of synthetic resin such as polystylene, vinylchloride resin, etc. or metal plate such as stainless plate are integrally disposed to the inner surface of the vessel main body. The cover member also has the same structure. (Sekiya, K.)

  19. Tempest in a vessel

    International Nuclear Information System (INIS)

    Barre, Bertrand

    2015-01-01

    As the ASN made some statements about anomalies of carbon content in the EPR vessel bottom and top, the author recalls and comments some technical issues to better understand the information published on this topic. He notably addresses the role of the vessel, briefly indicates its operating conditions, shape and structure, and mechanical components for the top, its material and mechanical properties, and test samples used to assess mechanical properties. He also comments the phenomenon of radio-induced embrittlement, the vessel manufacturing process, and evokes the applicable regulations. He quotes and comments statements made by the ASN and Areva which evoke further assessments of the concerned components

  20. Prestressed concrete pressure vessels for boiling water reactors

    International Nuclear Information System (INIS)

    Menon, S.

    1979-12-01

    Following a general description of the Scandinavian cooperative project on prestressed concrete pressure vessels for boiling water reactors, detailed discussion is given in four appendices of the following aspects: the verification programme of tests and studies, the development and testing of a liner venting system, a preliminary safety philosophy and comparative assessment of cold and hot liners. Vessel failure probability is briefly discussed and some figures presented. The pressure gradients in the vessel wall resulting from various stipulated linear cracks, with a liner venting system are presented graphically. (JIW)

  1. RAPID COMMUNICATION: Magnetic resonance imaging inside metallic vessels

    Science.gov (United States)

    Han, Hui; Balcom, Bruce J.

    2010-10-01

    We introduce magnetic resonance imaging (MRI) measurements inside metallic vessels. Until now, MRI has been unusable inside metallic vessels because of eddy currents in the walls. We have solved the problem and generated high quality images by employing a magnetic field gradient monitoring method. The ability to image within metal enclosures and structures means many new samples and systems are now amenable to MRI. Most importantly this study will form the basis of new MRI-compatible metallic pressure vessels, which will permit MRI of macroscopic systems at high pressure.

  2. Vessel Enhancement and Segmentation of 4D CT Lung Image Using Stick Tensor Voting

    Science.gov (United States)

    Cong, Tan; Hao, Yang; Jingli, Shi; Xuan, Yang

    2016-12-01

    Vessel enhancement and segmentation plays a significant role in medical image analysis. This paper proposes a novel vessel enhancement and segmentation method for 4D CT lung image using stick tensor voting algorithm, which focuses on addressing the vessel distortion issue of vessel enhancement diffusion (VED) method. Furthermore, the enhanced results are easily segmented using level-set segmentation. In our method, firstly, vessels are filtered using Frangi's filter to reduce intrapulmonary noises and extract rough blood vessels. Secondly, stick tensor voting algorithm is employed to estimate the correct direction along the vessel. Then the estimated direction along the vessel is used as the anisotropic diffusion direction of vessel in VED algorithm, which makes the intensity diffusion of points locating at the vessel wall be consistent with the directions of vessels and enhance the tubular features of vessels. Finally, vessels can be extracted from the enhanced image by applying level-set segmentation method. A number of experiments results show that our method outperforms traditional VED method in vessel enhancement and results in satisfied segmented vessels.

  3. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  4. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  5. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  6. 2011 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  7. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  8. 2013 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  9. Maury Journals - US Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — U.S. vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  10. Coastal Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels that have been issued a Federal permit for the Gulf of Mexico reef fish,...

  11. Reactor pressure vessel support

    International Nuclear Information System (INIS)

    Butti, J.P.

    1977-01-01

    A link and pin support system provides the primary vertical and lateral support for a nuclear reactor pressure vessel without restricting thermally induced radial and vertical expansion and contraction. (Auth.)

  12. 2013 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  13. 2013 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  14. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  15. Ocean Station Vessel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean Station Vessels (OSV) or Weather Ships captured atmospheric conditions while being stationed continuously in a single location. While While most of the...

  16. Vessel Sewage Discharges

    Science.gov (United States)

    Vessel sewage discharges are regulated under Section 312 of the Clean Water Act, which is jointly implemented by the EPA and Coast Guard. This homepage links to information on marine sanitation devices and no discharge zones.

  17. Reactor pressure vessel design

    International Nuclear Information System (INIS)

    Foehl, J.

    1998-01-01

    As a result of the popularity of the Agencies report 'Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels' of 1975, it was decided that another report on this broad subject would be of use. In this report, background and contemporary views on specially identified areas of the subject are considered as self-contained chapters, written by experts. In chapter 2, the general principles of reactor pressure vessel design are elaborated. Crack and fracture initiation and propagation are treated in some detail

  18. Graywater Discharges from Vessels

    Science.gov (United States)

    2011-11-01

    metals (e.g., cadmium, chromium, lead, copper , zinc, silver, nickel, and mercury), solids, and nutrients (USEPA, 2008b; USEPA 2010). Wastewater from... flotation ), and disinfection (using ultraviolet light) as compared to traditional Type II MSDs that use either simple maceration and chlorination, or...Coliform Naval Vessels Oceanographic Vessels Small Cruise Ships 25a Vendor 2 Hamann AG Biological Treatment with Dissolved Air Flotation and

  19. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  20. Heat insulation device for reactor pressure vessel in water

    International Nuclear Information System (INIS)

    Nakamura, Heiichiro; Tanaka, Yoshimi.

    1993-01-01

    Outer walls of a reactor pressure vessel are covered with water-tight walls made of metals. A heat insulation metal material is disposed between them. The water tight walls are joined by welding and flanges. A supply pipeline for filling gases and a discharge pipeline are in communication with the inside of the water tight walls. Further, a water detector is disposed in the midway of the gas discharge pipeline. With such a constitution, the following advantages can be attained. (1) Heat transfer from the reactor pressure vessel to water of a reactor container can be suppressed by filled gases and heat insulation metal material. (2) Since the pressure at the inside of the water tight walls can be equalized with the pressure of the inside of the reactor container, the thickness of the water-tight walls can be reduced. (3) Since intrusion of water to the inside of the walls due to rupture of the water tight walls is detected by the water detector, reactor scram can be conducted rapidly. (4) The sealing property of the flange joint portion is sufficient and detaching operation thereof is easy. (I.S.)

  1. FFTF and CRBRP reactor vessels

    International Nuclear Information System (INIS)

    Morgan, R.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) reactor vessel and the Clinch River Breeder Reactor Plant (CRBRP) reactor vessel each serve to enclose a fast spectrum reactor core, contain the sodium coolant, and provide support and positioning for the closure head and internal structure. Each vessel is located in its reactor cavity and is protected by a guard vessel which would ensure continued decay heat removal capability should a major system leak develop. Although the two plants have significantly different thermal power ratings, 400 megawatts for FFTF and 975 megawatts for CRBRP, the two reactor vessels are comparable in size, the CRBRP vessel being approximately 28% longer than the FFTF vessel. The FFTF vessel diameter was controlled by the space required for the three individual In-Vessel Handling Machines and Instrument Trees. Utilization of the triple rotating plug scheme for CRBRP refueling enables packaging of the larger CRBRP core in a vessel the same diameter as the FFTF vessel

  2. Trajectory planning of tokamak flexible in-vessel inspection robot

    International Nuclear Information System (INIS)

    Wang, Hesheng; Chen, Weidong; Lai, Yinping; He, Tao

    2015-01-01

    Highlights: • A tokamak flexible in-vessel inspection robot is designed. • Two trajectory planning methods are used to ensure the full coverage of the first wall scanning. • The method is tested on a simulated platform of EAST with the flexible in-vessel inspection robot. • Experimental results show the effectiveness of the proposed algorithm. - Abstract: Tokamak flexible in-vessel inspection robot is mainly designed to carry a camera for close observation of the first wall of the vacuum vessel, which is essential for the maintenance of the future tokamak reactor without breaking the working condition of the vacuum vessel. A tokamak flexible in-vessel inspection robot is designed. In order to improve efficiency of the remote maintenance, it is necessary to design a corresponding trajectory planning algorithm to complete the automatic full coverage scanning of the complex tokamak cavity. Two different trajectory planning methods, RS (rough scanning) and FS (fine scanning), according to different demands of the task, are used to ensure the full coverage of the first wall scanning. To quickly locate the damage position, the first trajectory planning method is targeted for quick and wide-ranging scan of the tokamak D-shaped section, and the second one is for careful observation. Furthermore, both of the two different trajectory planning methods can ensure the full coverage of the first wall scanning with an optimal end posture. The method is tested on a simulated platform of EAST (Experimental Advanced Superconducting Tokamak) with the flexible in-vessel inspection robot, and the results show the effectiveness of the proposed algorithm.

  3. Trajectory planning of tokamak flexible in-vessel inspection robot

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hesheng [Department of Automation, Shanghai Jiao Tong University, 200240 Shanghai (China); Key Laboratory of System Control and Information Processing, Ministry of Education of China, 200240 Shanghai (China); Chen, Weidong, E-mail: wdchen@sjtu.edu.cn [Department of Automation, Shanghai Jiao Tong University, 200240 Shanghai (China); Key Laboratory of System Control and Information Processing, Ministry of Education of China, 200240 Shanghai (China); Lai, Yinping; He, Tao [Department of Automation, Shanghai Jiao Tong University, 200240 Shanghai (China); Key Laboratory of System Control and Information Processing, Ministry of Education of China, 200240 Shanghai (China)

    2015-10-15

    Highlights: • A tokamak flexible in-vessel inspection robot is designed. • Two trajectory planning methods are used to ensure the full coverage of the first wall scanning. • The method is tested on a simulated platform of EAST with the flexible in-vessel inspection robot. • Experimental results show the effectiveness of the proposed algorithm. - Abstract: Tokamak flexible in-vessel inspection robot is mainly designed to carry a camera for close observation of the first wall of the vacuum vessel, which is essential for the maintenance of the future tokamak reactor without breaking the working condition of the vacuum vessel. A tokamak flexible in-vessel inspection robot is designed. In order to improve efficiency of the remote maintenance, it is necessary to design a corresponding trajectory planning algorithm to complete the automatic full coverage scanning of the complex tokamak cavity. Two different trajectory planning methods, RS (rough scanning) and FS (fine scanning), according to different demands of the task, are used to ensure the full coverage of the first wall scanning. To quickly locate the damage position, the first trajectory planning method is targeted for quick and wide-ranging scan of the tokamak D-shaped section, and the second one is for careful observation. Furthermore, both of the two different trajectory planning methods can ensure the full coverage of the first wall scanning with an optimal end posture. The method is tested on a simulated platform of EAST (Experimental Advanced Superconducting Tokamak) with the flexible in-vessel inspection robot, and the results show the effectiveness of the proposed algorithm.

  4. Automatic design of prestressed concrete vessels

    International Nuclear Information System (INIS)

    Sotomura, Kentaro; Murazumi, Yasuyuki

    1984-01-01

    Prestressed concrete appeared after high strnegth steel had been produced, therefore it has the history of only 40 years even in Europe where it was developed. High compressive force is given to concrete beforehand by high strength steel to resist tensile force. It is superior to ordinary steel in strength, economy, rust prevention, fire protection and workability, and it competes with ordinary steel in the fields of bridges, towers, water tanks, water pipes, barges, LPG and LNG tanks, reactor pressure vessels, reactor containment vessels and so on. The design of prestressed concrete containment vessels (PCCV) being constructed in Japan adopts the form of mounting a semi-spherical dome on a cylindrical wall of 43m inside diameter and about 1.5m thickness, and the steel pipe sheaths for inserting tendons are arranged in the wall. The Taisei Construction Co. has developed the PC-ADE system which enables the optimum design of PCCVs. The outline of the automatic design system, the design of tendon arrangement, the preparation of the data on the load for stress analysis, the stress analysis by axisymmetric finite element method and the calculation of cross sections are explained. Design is a creative activity, and in the design of PCCVs also, the intention of designers should be materialized when this program is utilized. (Kako, I.)

  5. Cooling of pressurized water nuclear reactor vessels

    International Nuclear Information System (INIS)

    Curet, H.D.

    1978-01-01

    The improvement of pressurized water nuclear reactor vessels comprising flow dividers providing separate and distinct passages for the flow of core coolant water from each coolant water inlet, the flow dividers being vertically disposed in the annular flow areas provided by the walls of the vessel, the thermal shield (if present), and the core barrel is described. In the event of rupture of one of the coolant water inlet lines, water, especially emergency core coolant water, in the intact lines is thus prevented from by-passing the core by circumferential flow around the outermost surface of the core barrel and is instead directed so as to flow vertically downward through the annulus area between the vessel wall and the core barrel in a more normal manner to increase the probability of cooling of the core by the available cooling water in the lower plenum, thus preventing or delaying thermal damage to the core, and providing time for other appropriate remedial or damage preventing action by the operator

  6. Spent nuclear fuel assembly storage vessel

    International Nuclear Information System (INIS)

    Yagishita, Takuya

    1998-01-01

    The vessel of the present invention promotes an effect of removing after heat of spent nuclear fuel assemblies so as not to give force to the storage vessel caused by expansion of heat removing partitioning plates. Namely, the vessel of the present invention comprises a cylinder body having closed upper and lower portions and a plurality of heat removing partitioning cylinders disposed each at a predetermined interval in the circumferential direction of the above-mentioned cylinder body. The heat removing partitioning cylinders comprises (1) first heat removing partitioning plates extended in the radial direction of the cylinder body and opposed at a predetermined gap in the circumferential direction of the cylinder body, and having the base ends on the side of the inner wall of the cylinder body being secured to the inner wall of the cylinder body and (2) a second heat removing plate for connecting the top ends of both opposed heat removing partitioning plates on the central side of the cylinder body with each other. Spent nuclear fuel assemblies are contained in a plurality of closed spaces surrounded by the first heat removing partitioning plates and the second heat removing partitioning plate. With such constitution, since after heat is partially transferred from the heat removing partitioning plates to the cylindrical body directly by heat conduction, the heat removing effect can be promoted compared with the prior art. (I.S.)

  7. Cooling system for the connecting rings of a fast neutron reactor vessel

    International Nuclear Information System (INIS)

    Martin, J.-P.; Malaval, Claude

    1974-01-01

    A description is given of a cooling system for the vessel connecting rings of a fast neutron nuclear reactor, particularly of a main vessel containing the core of the reactor and a volume of liquid metal coolant at high temperature and a safety vessel around the main vessel, both vessels being suspended to a rigid upper slab kept at a lower temperature. It is mounted in the annular space between the two vessels and includes a neutral gas circuit set up between the wall of the main vessel to be cooled and that of the safety vessel itself cooled from outer. The neutral gas system comprises a plurality of ventilators fitted in holes made through the thickness of the upper slab and opening on to the space between the two vessels. It also includes two envelopes lining the walls of these vessels, establishing with them small section channels for the circulation of the neutral gas cooled against the safety vessel and heated against the main vessel [fr

  8. [Microscopic investigation of vessel wall after endovascular catheter atherectomy].

    Science.gov (United States)

    Tsygankov, V N; Khovalkin, R G; Chekmareva, I A; Kalinin, D V; Filippova, E M

    2014-01-01

    Endovascular target catheter atherectomy (ETCA) - method of artery patency allowing to obtain occlusion substrate. Given the high destructive effect of atherectome's elements on tissue the objective was determination possibility of histological and electron microscopic investigation of this substrate after atherectomy. The research included 8 patients who underwent ETCA of legs arteries. It was observed substrate removal from broken stent in 1 case. 2 of 8 patients had diabetes. Obtained substrate was available for histological and electron microscopic investigation. Atherosclerosis was confirmed in all cases. It was not observed substrate significant morphological changes in patients with presence or absence of diabetes. Microscopic investigation of substrate from broken stent shows pronounced development of granulation tissue that was regarded as special form of reparative regeneration. Finding internal elastic membrane during microscopic investigation in some cases proves radical intervention. The authors consider that microscopic investigation of substrate after ETCA may be used for diagnosis verification, thorough analysis of morphological changes in lesion area and radicalism of atherectomy.

  9. Formal consensus to identify clinically important changes in management resulting from the use of cardiovascular magnetic resonance (CMR) in patients who activate the primary percutaneous coronary intervention (PPCI) pathway.

    Science.gov (United States)

    Pufulete, Maria; Brierley, Rachel C; Bucciarelli-Ducci, Chiara; Greenwood, John P; Dorman, Stephen; Anderson, Richard A; Harris, Jessica; McAlindon, Elisa; Rogers, Chris A; Reeves, Barnaby C

    2017-06-22

    To define important changes in management arising from the use of cardiovascular magnetic resonance (CMR) in patients who activate the primary percutaneous coronary intervention (PPCI) pathway. Formal consensus study using literature review and cardiologist expert opinion to formulate consensus statements and setting up a consensus panel to review the statements (by completing a web-based survey, attending a face-to-face meeting to discuss survey results and modify the survey to reflect group discussion and completing the modified survey to determine which statements were in consensus). Formulation of consensus statements: four cardiologists (two CMR and two interventional) and six non-clinical researchers. Formal consensus: seven cardiologists (two CMR and three interventional, one echocardiography and one heart failure). Forty-nine additional cardiologists completed the modified survey. Thirty-seven draft statements describing changes in management following CMR were generated; these were condensed into 12 statements and reviewed through the formal consensus process. Three of 12 statements were classified in consensus in the first survey; these related to the role of CMR in identifying the cause of out-of-hospital cardiac arrest, providing a definitive diagnosis in patients found to have unobstructed arteries on angiography and identifying patients with left ventricular thrombus. Two additional statements were in consensus in the modified survey, relating to the ability of CMR to identify patients who have a poor prognosis after PPCI and assess ischaemia and viability in patients with multivessel disease. There was consensus that CMR leads to clinically important changes in management in five subgroups of patients who activate the PPCI pathway. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Acrylic vessel cleaning tests

    International Nuclear Information System (INIS)

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-01-01

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory

  11. Automatic segmentation of myocardium at risk from contrast enhanced SSFP CMR: validation against expert readers and SPECT

    International Nuclear Information System (INIS)

    Tufvesson, Jane; Carlsson, Marcus; Aletras, Anthony H.; Engblom, Henrik; Deux, Jean-François; Koul, Sasha; Sörensson, Peder; Pernow, John; Atar, Dan; Erlinge, David; Arheden, Håkan; Heiberg, Einar

    2016-01-01

    Efficacy of reperfusion therapy can be assessed as myocardial salvage index (MSI) by determining the size of myocardium at risk (MaR) and myocardial infarction (MI), (MSI = 1-MI/MaR). Cardiovascular magnetic resonance (CMR) can be used to assess MI by late gadolinium enhancement (LGE) and MaR by either T2-weighted imaging or contrast enhanced SSFP (CE-SSFP). Automatic segmentation algorithms have been developed and validated for MI by LGE as well as for MaR by T2-weighted imaging. There are, however, no algorithms available for CE-SSFP. Therefore, the aim of this study was to develop and validate automatic segmentation of MaR in CE-SSFP. The automatic algorithm applies surface coil intensity correction and classifies myocardial intensities by Expectation Maximization to define a MaR region based on a priori regional criteria, and infarct region from LGE. Automatic segmentation was validated against manual delineation by expert readers in 183 patients with reperfused acute MI from two multi-center randomized clinical trials (RCT) (CHILL-MI and MITOCARE) and against myocardial perfusion SPECT in an additional set (n = 16). Endocardial and epicardial borders were manually delineated at end-diastole and end-systole. Manual delineation of MaR was used as reference and inter-observer variability was assessed for both manual delineation and automatic segmentation of MaR in a subset of patients (n = 15). MaR was expressed as percent of left ventricular mass (%LVM) and analyzed by bias (mean ± standard deviation). Regional agreement was analyzed by Dice Similarity Coefficient (DSC) (mean ± standard deviation). MaR assessed by manual and automatic segmentation were 36 ± 10 % and 37 ± 11 %LVM respectively with bias 1 ± 6 %LVM and regional agreement DSC 0.85 ± 0.08 (n = 183). MaR assessed by SPECT and CE-SSFP automatic segmentation were 27 ± 10 %LVM and 29 ± 7 %LVM respectively with bias 2 ± 7 %LVM. Inter-observer variability was 0 ± 3 %LVM for manual delineation and

  12. Vacuum vessel of thermonuclear device and manufacturing method thereof

    International Nuclear Information System (INIS)

    Kurita, Genichi; Nagashima, Keisuke; Uchida, Takaho; Shibui, Masanao; Ebisawa, Katsuyuki; Nakagawa, Satoshi.

    1997-01-01

    The present invention provides a vacuum vessel of a thermonuclear device using, as a material of a plasma vacuum vessel, a material to be less activated and having excellent strength as well as a manufacturing method thereof. Namely, the vacuum vessel is made of titanium or a titanium alloy. In addition, a liner layer comprising a manganese alloy, nickel alloy, nickel-chromium alloy or aluminum or aluminum alloy is formed. With such a constitution, the wall substrate made of titanium or a titanium alloy can be isolated by the liner from hydrogen or plasmas. As a result, occlusion of hydrogen to titanium or the titanium alloy can be prevented thereby enabling to prevent degradation of the material of the wall substrate of the vacuum vessel. In addition, since the liner layer has relatively high electric resistance, a torus circumferential resistance value required for plasma ignition can be ensured by using it together with the vessel wall made of titanium alloy. (I.S.)

  13. Stress analysis of blanket vessel for JAERI experimental fusion reactor

    International Nuclear Information System (INIS)

    Sako, K.; Minato, A.

    1979-01-01

    A blanket structure of JAERI Experimental Fusion Reactor (JXFR) consists of about 2,300 blanket cells with round cornered rectangular cross sections (twelve slightly different shapes) and is placed in a vacuum vessel. Each blanket vessel is a double-walled thin-shell structure made of Type 316 stainless steel with a spherical domed surface at the plasma side. Ribs for coolant channel are provided between inner and outer walls. The blanket cell contains Li 2 O pebbles and blocks for tritium breeding and stainless steel blocks for neutron reflection. A coolant is helium gas at 10 kgf/cm 2 (0.98 MPa) and its inlet and outlet temperatures are 300 0 C and 500 0 C. The maxima of heat flux and nuclear heating rate at the first wall are 12 W/cm 2 and 2 W/cc. A design philosophy of the blanket structure is based on high tritium breeding ratio and more effective shielding performance. The thin-shell vessel with a rectangular cross section satisfies the design philosophy. We have designed the blanket structure so that the adjacent vessels are mutually supporting in order to decrease the large deformation and stress due to internal pressure in case of the thin-shell vessel. (orig.)

  14. Criticality Safety Evaluation for Small Sample Preparation and Non-Destructive Assay (NDA) Operations in Wing 7 Basement of the CMR Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kunkle, Paige Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Zhang, Ning [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-02

    Nuclear Criticality Safety (NCS) has reviewed the fissionable material small sample preparation and NDA operations in Wing 7 Basement of the CMR Facility. This is a Level-1 evaluation conducted in accordance with NCS-AP-004 [Reference 1], formerly NCS-GUIDE-01, and the guidance set forth on use of the Standard Criticality Safety Requirements (SCSRs) [Reference 2]. As stated in Reference 2, the criticality safety evaluation consists of both the SCSR CSED and the SCSR Application CSED. The SCSR CSED is a Level-3 CSED [Reference 3]. This Level-1 CSED is the SCSR Application CSED. This SCSR Application (Level-1) evaluation does not derive controls, it simply applies controls derived from the SCSR CSED (Level-3) for the application of operations conducted here. The controls derived in the SCSR CSED (Level-3) were evaluated via the process described in Section 6.6.5 of SD-130 (also reproduced in Section 4.3.5 of NCS-AP-004 [Reference 1]) and were determined to not meet the requirements for consideration of elevation into the safety basis documentation for CMR. According to the guidance set forth on use of the SCSRs [Reference 2], the SCSR CSED (Level-3) is also applicable to the CMR Facility because the process and the normal and credible abnormal conditions in question are bounded by those that are described in the SCSR CSED. The controls derived in the SCSR CSED include allowances for solid materials and solution operations. Based on the operations conducted at this location, there are less-than-accountable (LTA) amounts of 233U. Based on the evaluation documented herein, the normal and credible abnormal conditions that might arise during the execution of this process will remain subcritical with the following recommended controls.

  15. Heissdampfreaktor (HDR) steel-containment-vessel and floodwater-storage-tank structural-dynamics tests

    International Nuclear Information System (INIS)

    Arendts, J.G.

    1982-01-01

    Inertance (vibration) testing of two significant vessels at the Heissdampfreaktor (HDR) facility, located near Kahl, West Germany, was recently completed. Transfer functions were obtained for determination of the modal properties (frequencies, mode shapes and damping) of the vessels using two different test methods for comparative purposes. One of the vessels tested was the steel containment vessel (SCV). The SCV is approximately 180 feet high and 65 feet in diameter with a 1.2-inch wall thickness. The other vessel, called the floodwater storage tank (FWST), is a vertically standing vessel approximately 40 feet high and 10 feet in diameter with a 1/2-inch wall thickness. The FWST support skirt is square (in plan views) with its corners intersecting the ellipsoidal bottom head near the knuckle region

  16. Status of the ITER vacuum vessel construction

    Energy Technology Data Exchange (ETDEWEB)

    Choi, C.H.; Sborchia, C.; Ioki, K.; Giraud, B.; Utin, Yu.; Sa, J.W. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Wang, X., E-mail: xiaoyuwww@gmail.com [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Teissier, P.; Martinez, J.M.; Le Barbier, R.; Jun, C.; Dani, S.; Barabash, V.; Vertongen, P.; Alekseev, A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Jucker, P.; Bayon, A. [F4E, c/ Josep Pla, n. 2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain); Pathak, H.; Raval, J. [ITER-India, IPR, A-29, Electronics Estate, GIDC, Sector-25, Gandhinagar 382025 (India); Ahn, H.J. [ITER Korea, National Fusion Research Institute, Daejeon (Korea, Republic of); and others

    2014-10-15

    Highlights: • Final design of the ITER vacuum vessel (VV). • Procurement of the ITER VV. • Manufacturing results of real scale mock-ups. • Manufacturing status of the VV in domestic agencies. - Abstract: The ITER vacuum vessel (VV) is under manufacturing by four domestic agencies after completion of engineering designs that have been approved by the Agreed Notified Body (ANB). Manufacturing designs of the VV have been being completed, component by component, by accommodating requirements of the RCC-MR 2007 edition. Manufacturing of the VV first sector has been started in February 2012 in Korea and in-wall shielding in May 2013 in India. EU will start manufacturing of its first sector from September 2013 and Russia the upper port by the end of 2013. All DAs have manufactured several mock-ups including real-size ones to justify/qualify and establish manufacturing techniques and procedures.

  17. Modeling and measurement of the motion of the DIII-D vacuum vessel during vertical instabilities

    International Nuclear Information System (INIS)

    Reis, E.; Blevins, R.D.; Jensen, T.H.; Luxon, J.L.; Petersen, P.I.; Strait, E.J.

    1991-11-01

    The motions of the D3-D vacuum vessel during vertical instabilities of elongated plasmas have been measured and studied over the past five years. The currents flowing in the vessel wall and the plasma scrapeoff layer were also measured and correlated to a physics model. These results provide a time history load distribution on the vessel which were input to a dynamic analysis for correlation to the measured motions. The structural model of the vessel using the loads developed from the measured vessel currents showed that the calculated displacement history correlated well with the measured values. The dynamic analysis provides a good estimate of the stresses and the maximum allowable deflection of the vessel. In addition, the vessel motions produce acoustic emissions at 21 Hertz that are sufficiently loud to be felt as well as heard by the D3-D operators. Time history measurements of the sounds were correlated to the vessel displacements. An analytical model of an oscillating sphere provided a reasonable correlation to the amplitude of the measured sounds. The correlation of the theoretical and measured vessel currents, the dynamic measurements and analysis, and the acoustic measurements and analysis show that: (1) The physics model can predict vessel forces for selected values of plasma resistivity. The model also predicts poloidal and toroidal wall currents which agree with measured values; (2) The force-time history from the above model, used in conjunction with an axisymmetric structural model of the vessel, predicts vessel motions which agree well with measured values; (3) The above results, input to a simple acoustic model predicts the magnitude of sounds emitted from the vessel during disruptions which agree with acoustic measurements; (4) Correlation of measured vessel motions with structural analysis shows that a maximum vertical motion of the vessel up to 0.24 in will not overstress the vessel or its supports. 11 refs., 10 figs., 1 tab

  18. In service inspection of SUPERPHENIX 1 vessels: MIR

    International Nuclear Information System (INIS)

    Asty, M.; Viard, J.; Lerat, B.; Saglio, R.

    1985-01-01

    Although no in-service inspection constraints were imposed on the Phenix vessels, the Safety Authorities asked that the design of SUPERPHENIX 1 makes it possible to monitor throughout the lifetime of the reactor, surface and internal defects on the main vessel. A pool design and the presence of heat baffles inside the main vessel make access from the inside of the vessel impossible. Thus, an inspection can only be performed from the outside of the main vessel: the distance between the walls of the main and safety vessels is such that an inspection device can be introduced into the corresponding space. As the design of the reactor precludes radiographic inspection, the method which was selected for monitoring internal defects in the main vessel is ultrasonics. However, the anisotropic structure of austenitic stainless steel welds limits the performance of this technique. The authors present the in-service inspection device, MIR, which has been specially developed for the visual and ultrasonic examination of SUPERPHENIX 1 vessels

  19. First wall

    International Nuclear Information System (INIS)

    Omori, Junji.

    1991-01-01

    Graphite and C/C composite are used recently for the first wall of a thermonuclear device since materials with small atom number have great impurity allowable capacity for plasmas. Among them, those materials having high thermal conduction are generally anisotropic and have an upper limit for the thickness upon production. Then, anisotropic materials are used for a heat receiving plate, such that the surfaces of the heat receiving plate on the side of lower heat conductivity are brought into contact with each other, and the side of higher thermal conductivity is arranged in parallel with small radius direction and the toroidal direction of the thermonuclear device. As a result, the incident heat on an edge portion can be transferred rapidly to the heat receiving plate, which can suppress the temperature elevation at the surface to thereby reduce the amount of abrasion. Since the heat expansion coefficient of the anisotropic materials is great in the direction of the lower heat conductivity and small in the direction of the higher heat conductivity, the gradient of a thermal load distribution in the direction of the higher heat expansion coefficient is small, and occurrence of thermal stresses due to temperature difference is reduced, to improve the reliability. (N.H.)

  20. Falling walls

    CERN Multimedia

    It was 20 years ago this week that the Berlin wall was opened for the first time since its construction began in 1961. Although the signs of a thaw had been in the air for some time, few predicted the speed of the change that would ensue. As members of the scientific community, we can take a moment to reflect on the role our field played in bringing East and West together. CERN’s collaboration with the East, primarily through links with the Joint Institute for Nuclear Research, JINR, in Dubna, Russia, is well documented. Less well known, however, is the role CERN played in bringing the scientists of East and West Germany together. As the Iron curtain was going up, particle physicists on both sides were already creating the conditions that would allow it to be torn down. Cold war historian Thomas Stange tells the story in his 2002 CERN Courier article. It was my privilege to be in Berlin on Monday, the anniversary of the wall’s opening, to take part in a conference entitled &lsquo...

  1. New baking system for the RFX vacuum vessel

    International Nuclear Information System (INIS)

    Collarin, P.; Luchetta, A.; Sonato, P.; Toigo, V.; Zaccaria, P.; Zollino, G.

    1996-01-01

    A heating system based on eddy currents has been developed for the vacuum vessel of the RFX Reversed Field Pinch device. After a testing phase, carried out at low power, the final power supply system has been designed and installed. It has been used during last year to bake out the vessel and the graphite first wall up to 320 degree C. Recently the heating system has been completed with a control system that allows for baking sessions with an automatic control of the vacuum vessel temperature and for pulse sessions with a heated first wall. After the description of the preliminary analyses and tests, and of the main characteristics of the power supply and control systems, the experimental results of the baking sessions performed during last year are presented. 6 refs., 7 figs

  2. New baking system for the RFX vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Collarin, P.; Luchetta, A.; Sonato, P.; Toigo, V.; Zaccaria, P.; Zollino, G. [Universita di Padova (Italy)

    1996-12-31

    A heating system based on eddy currents has been developed for the vacuum vessel of the RFX Reversed Field Pinch device. After a testing phase, carried out at low power, the final power supply system has been designed and installed. It has been used during last year to bake out the vessel and the graphite first wall up to 320{degree}C. Recently the heating system has been completed with a control system that allows for baking sessions with an automatic control of the vacuum vessel temperature and for pulse sessions with a heated first wall. After the description of the preliminary analyses and tests, and of the main characteristics of the power supply and control systems, the experimental results of the baking sessions performed during last year are presented. 6 refs., 7 figs.

  3. An interior vessel viewing system for DIII-D

    International Nuclear Information System (INIS)

    Senior, R.

    1989-11-01

    It was anticipated that there could be damage to the interior walls of the vacuum vessel during operations of the DIII-D tokamak. A method of viewing the inside of the vessel from the outside was required, that would allow the interior walls to be inspected visually for damage and to locate any debris resulting from operations. A miniature closed circuit television color camera system was developed which could be inserted into one of several ports of the vessel during a 'clean' vent, i.e., vented to inert gas. The system has pan, tilt and zoom capability and carries its own lighting. The use of this system allows a quick assessment of the condition of the vessel to be made under 'clean' vent conditions. This precludes the need for the permit process and manned entry into the vessel which would allow air inside the vessel. A permanent record of the inspection can then be made on video tape. The design and configuration of this camera system is presented and its use as a diagnostic tool discussed. 2 refs., 5 figs

  4. Integral experiments on in-vessel coolability and vessel creep: results and analysis of the FOREVER-C1 test

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R.; Nourgaliev, R.R.; Dinh, T.N.; Karbojian, A. [Division of Nuclear Power Safety, Royal Institute of Technology, Drottning Kristinas Vaeg., Stockholm (Sweden)

    1999-07-01

    This paper describes the FOREVER (Failure Of REactor VEssel Retention) experimental program, which is currently underway at the Division of Nuclear Power Safety, Royal Institute of Technology (RIT/NPS). The objectives of the FOREVER experiments are to obtain data and develop validated models (i) on the melt coolability process inside the vessel, in the presence of water (in particular, on the efficacy of the postulated gap cooling to preclude vessel failure); and (ii) on the lower head failure due to the creep process in the absence of water inside and/or outside the lower head. The paper presents the experimental results and analysis of the first FOREVER-C1 test. During this experiment, the 1/10th scale pressure vessel, heated to about 900degC and pressurized to 26 bars, was subjected to creep deformation in a non-stop 24-hours test. The vessel wall displacement data clearly shows different stages of the vessel deformation due to thermal expansion, elastic, plastic and creep processes. The maximum displacement was observed at the lowermost region of the vessel lower plenum. Information on the FOREVER-C1 measured thermal characteristics and analysis of the observed thermal and structural behavior is presented. The coupled nature of thermal and mechanical processes, as well as the effect of other system conditions (such as depressurization) on the melt pool and vessel temperature responses are analyzed. (author)

  5. Pressure vessel integrity 1991

    International Nuclear Information System (INIS)

    Bhandari, S.; Doney, R.O.; McDonald, M.S.; Jones, D.P.; Wilson, W.K.; Pennell, W.E.

    1991-01-01

    This volume contains papers relating to the structural integrity assessment of pressure vessels and piping, with special emphasis on nuclear industry applications. The papers were prepared for technical sessions developed under the sponsorship of the ASME Pressure Vessels and Piping Division Committees for Codes and Standards, Computer Technology, Design and Analysis, and Materials Fabrication. They were presented at the 1991 Pressure Vessels and Piping Division Conference in San Diego, California, June 23-27. The primary objective of the sponsoring organization is to provide a forum for the dissemination and discussion of information on development and application of technology for the structural integrity assessment of pressure vessels and piping. This publication includes contributions from authors from Australia, France, Japan, Sweden, Switzerland, the United Kingdom, and the United States. The papers here are organized in six sections, each with a particular emphasis as indicated in the following section titles: Fracture Technology Status and Application Experience; Crack Initiation, Propagation and Arrest; Ductile Tearing; Constraint, Stress State, and Local-Brittle-Zones Effects; Computational Techniques for Fracture and Corrosion Fatigue; and Codes and Standards for Fatigue, Fracture and Erosion/Corrosion

  6. The reactor vessel steels

    International Nuclear Information System (INIS)

    Bilous, W.; Hajewska, E.; Szteke, W.; Przyborska, M.; Wasiak, J.; Wieczorkowski, M.

    2005-01-01

    In the paper the fundamental steels using in the construction of pressure vessel water reactor are discussed. The properties of these steels as well as the influence of neutron irradiation on its degradation in the time of exploitation are also done. (authors)

  7. Vacuum distilling vessel

    Energy Technology Data Exchange (ETDEWEB)

    Reik, H

    1928-12-27

    Vacuum distilling vessel for mineral oil and the like, characterized by the ring-form or polyconal stiffeners arranged inside, suitably eccentric to the casing, being held at a distance from the casing by connecting members of such a height that in the resulting space if necessary can be arranged vapor-distributing pipes and a complete removal of the residue is possible.

  8. Visualization of vessel traffic

    NARCIS (Netherlands)

    Willems, C.M.E.

    2011-01-01

    Moving objects are captured in multivariate trajectories, often large data with multiple attributes. We focus on vessel traffic as a source of such data. Patterns appearing from visually analyzing attributes are used to explain why certain movements have occurred. In this research, we have developed

  9. GOLD PRESSURE VESSEL SEAL

    Science.gov (United States)

    Smith, A.E.

    1963-11-26

    An improved seal between the piston and die member of a piston-cylinder type pressure vessel is presented. A layer of gold, of sufficient thickness to provide an interference fit between the piston and die member, is plated on the contacting surface of at least one of the members. (AEC)

  10. Reactor vessel stud tensioner

    International Nuclear Information System (INIS)

    Malandra, L.J.; Beer, R.W.; Salton, R.B.; Spiegelman, S.R.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner, for facilitating the loosening or tightening of a stud nut on a reactor vessel stud, has gripper jaws which when the tensioner is lowered into engagement with the upper end of the stud are moved inwards to grip the upper end and which when the tensioner is lifted move outward to release the upper end. (author)

  11. Plasma-Wall Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Li, J; Chen, J L [Institute of Plasma Physics, Chinese Academy of Sciences (China); Guo, H Y [Tri Alpha Energy (United States); Institute of Plasma Physics, Chinese Academy of Sciences (China); McCracken, G M [Culham Science Centre, UKAEA, Abingdon (United Kingdom)

    2012-09-15

    The problem of impurities in fusion plasmas has been recognized since the beginning of the fusion programme. Early experiments in glass vacuum vessels released gas from the wall to such an extent that the radiation from the impurities prevented the plasma from being heated above about 50 eV. The radiative power loss is principally due to line radiation from partially stripped ions, which is particularly a problem during the plasma startup phase. Another problem is fuel dilution, which arises because impurity atoms produce many electrons and, for a given plasma pressure, these electrons take the place of fuel particles. Impurities can also lead to disruptions, as a result of edge cooling and consequent current profile modification. The fractional impurity level which radiates 10% of the total thermonuclear power for a 10 keV plasma is 50% for helium, 7% for carbon, and less than 0.1% for molybdenum. Clearly, impurities of low atomic number are a much less serious problem than those of high atomic number. (author)

  12. Characteristics of carotid atherosclerotic plaques of chronic lipid apheresis patients as assessed by In Vivo High-Resolution CMR - a comparative analysis

    Directory of Open Access Journals (Sweden)

    Grimm Jochen M

    2012-11-01

    Full Text Available Abstract Background Components of carotid atherosclerotic plaques can reliably be identified and quantified using high resolution in vivo 3-Tesla CMR. It is suspected that lipid apheresis therapy in addition to lowering serum lipid levels also has an influence on development and progression of atherosclerotic plaques. The purpose of this study was to evaluate the influence of chronic lipid apheresis (LA on the composition of atherosclerotic carotid plaques. Methods 32 arteries of 16 patients during chronic LA-therapy with carotid plaques and stenosis of 1–80% were matched according to degree of stenosis with 32 patients, who had recently suffered an ischemic stroke. Of these patients only the asymptomatic carotid artery was analyzed. All patients underwent black-blood 3 T CMR of the carotids using parallel imaging and dedicated surface coils. Cardiovascular risk factors were recorded. Morphology and composition of carotid plaques were evaluated. For statistical evaluation Fisher’s Exact and unpaired t-test were used. A p-value Results Patients in the LA-group were younger (63.5 vs. 73.9. years, p2, p Conclusion Results of this study suggest that, despite a severer risk profile for cardiovascular complications in LA-patients, chronic LA is associated with significantly lower lipid content in carotid plaques compared to plaques of patients without LA with similar degrees of stenosis, which is characteristic of clinically stable plaques.

  13. Light Water Reactor-Pressure Vessel Surveillance project computer system

    International Nuclear Information System (INIS)

    Merriman, S.H.

    1980-10-01

    A dedicated process control computer has been implemented for regulating the metallurgical Pressure Vessel Wall Benchmark Facility (PSF) at the Oak Ridge Research Reactor. The purpose of the PSF is to provide reliable standards and methods by which to judge the radiation damage to reactor pressure vessel specimens. Benchmark data gathered from the PSF will be used to improve and standardize procedures for assessing the remaining safe operating lifetime of aging reactors. The computer system controls the pressure vessel specimen environment in the presence of gamma heating so that in-vessel conditions are simulated. Instrumented irradiation capsules, in which the specimens are housed, contain temperature sensors and electrical heaters. The computer system regulates the amount of power delivered to the electrical heaters based on the temperature distribution within the capsules. Time-temperature profiles are recorded along with reactor conditions for later correlation with specimen metallurgical changes

  14. Vessel used in radiation counting to determine radioactivity levels

    International Nuclear Information System (INIS)

    Charlton, J.C.; Glover, J.S.; Shephard, B.P.

    1977-01-01

    This invention concerns the vessels used in radiation counting to determine radioactivity levels. These vessels prove to be particularly useful in analyses of the kind where a radioactive element or compound is separated into two phases and the radioactivity of one phase is determined. Such a vessel used in the counting of radiation includes an organic plastic substance tube appreciably cylindrical in shape whose upper end is open whilst the lower end is closed and integral with it, and an anti-radiation shield in metal or in metal reinforced plastic located at the lower end of the tube and extending along the wall of the tube up to a given height. The vessel contains a reaction area of 1 to 10 ml for holding fluid reagents [fr

  15. Automatic Segmentation of Vessels in In-Vivo Ultrasound Scans

    DEFF Research Database (Denmark)

    Tamimi-Sarnikowski, Philip; Brink-Kjær, Andreas; Moshavegh, Ramin

    2017-01-01

    presents a fully automatic segmentation algorithm, for robustly segmenting the vessel lumen in longitudinal B-mode ultrasound images. The automatic segmentation is performed using a combination of B-mode and power Doppler images. The proposed algorithm includes a series of preprocessing steps, and performs......Ultrasound has become highly popular to monitor atherosclerosis, by scanning the carotid artery. The screening involves measuring the thickness of the vessel wall and diameter of the lumen. An automatic segmentation of the vessel lumen, can enable the determination of lumen diameter. This paper...... a vessel segmentation by use of the marker-controlled watershed transform. The ultrasound images used in the study were acquired using the bk3000 ultrasound scanner (BK Ultrasound, Herlev, Denmark) with two transducers ”8L2 Linear” and ”10L2w Wide Linear” (BK Ultrasound, Herlev, Denmark). The algorithm...

  16. Safety margins of PWR irradiated vessels - The Chooz A issue

    Energy Technology Data Exchange (ETDEWEB)

    Hedin, F; Barthelet, B [Electricite de France (EDF), 75 - Paris (France); Guilleret, J C

    1988-12-31

    In 1986, some irradiated specimen of CHOOZ A (SENA) vessel showed a significant excess of {delta} RTNDT to former previsions. The lack of data on one of the two irradiated shells, and discrepancies between dosimeters results and available previous fluence calculations whose accuracy was questionable, cause the safety authorities to require an important complementary work program before putting again the plant on the grid after 1987 fuel reloading. These works are presented and discussed. They lead to a state that a conservative to day value of the vessel RTNDT is 64 degrees Celsius and that there is no underclad defect in the vessel wall and welds. Then the plant was allowed to restart with certitude that vessel irradiation will not impair its lifetime. (author). 4 refs.

  17. Calculation of voltages and currents induced in the vacuum vessel of ASDEX by plasma disruptions

    International Nuclear Information System (INIS)

    Preis, H.

    1978-01-01

    An approximation method is used to analyze the electromagnetic diffusion process induced in the walls of the ASDEX vacuum vessel by plasma disruptions. For this purpose the rotational-symmetric vessel is regarded as N = 82 circular conductors connected in parallel and inductively coupled with one another and with the plasma. The transient currents and voltages occurring in this circuit are calculated with computer programs. From the calculated currents it is possible to determine the time behavior of the distributions of the current density and magnetic force density in the vessel walls. (orig.) [de

  18. VISA-2, Reactor Vessel Failure Probability Under Thermal Shock

    International Nuclear Information System (INIS)

    Simonen, F.; Johnson, K.

    1992-01-01

    1 - Description of program or function: VISA2 (Vessel Integrity Simulation Analysis) was developed to estimate the failure probability of nuclear reactor pressure vessels under pressurized thermal shock conditions. The deterministic portion of the code performs heat transfer, stress, and fracture mechanics calculations for a vessel subjected to a user-specified temperature and pressure transient. The probabilistic analysis performs a Monte Carlo simulation to estimate the probability of vessel failure. Parameters such as initial crack size and position, copper and nickel content, fluence, and the fracture toughness values for crack initiation and arrest are treated as random variables. Linear elastic fracture mechanics methods are used to model crack initiation and growth. This includes cladding effects in the heat transfer, stress, and fracture mechanics calculations. The simulation procedure treats an entire vessel and recognizes that more than one flaw can exist in a given vessel. The flaw model allows random positioning of the flaw within the vessel wall thickness, and the user can specify either flaw length or length-to-depth aspect ratio for crack initiation and arrest predictions. The flaw size distribution can be adjust on the basis of different inservice inspection techniques and inspection conditions. The toughness simulation model includes a menu of alternative equations for predicting the shift in the reference temperature of the nil-ductility transition. 2 - Method of solution: The solution method uses closed form equations for temperatures, stresses, and stress intensity factors. A polynomial fitting procedure approximates the specified pressure and temperature transient. Failure probabilities are calculated by a Monte Carlo simulation. 3 - Restrictions on the complexity of the problem: Maxima of 30 welds. VISA2 models only the belt-line (cylindrical) region of a reactor vessel. The stresses are a function of the radial (through-wall) coordinate only

  19. Calculation of the electromagnetic forces on the ASDEX upgrade vacuum vessel on disruption of the plasma current

    International Nuclear Information System (INIS)

    Preis, H.

    1986-01-01

    This study investigates the magnetic field diffusion through the vacuum vessel of the ASDEX Upgrade tokamak that occurs on sudden disruption of the plasma current. Eddy currents are thereby produced in the vessel wall. Their time behaviour and distribution are determined. Furthermore, the vessel is permeated by various magnetic fields which, together with the eddy currents, exert magnetic forces in the vessel wall. These are also calculated. These numerical analyses are performed for two of the modes of operation envisaged for ASDEX Upgrade: the so-called limiter and single-null magnetic field configurations. (orig.)

  20. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  1. The evaluation of pressure effects on the ex-vessel cooling for KNGR with MELCOR

    International Nuclear Information System (INIS)

    Park, Jong Hwa; Park, Soo Yong; Kim, Dong Ha

    2001-03-01

    In this report, the effect of external vessel cooling on debris coolability and vessel integrity for the KNGR were examined from the two typical pressure range of high(170 bar) and low(5 bar)case using the lower plenum model in MELCOR1.8.4. As the conditions of these calculations, 80 ton of debris was relocated simultaneously into the lower vessel head and the debris relocation temperature from the core region was 2700 K. The decay heat has been assumed to be that of one hour after reactor shutdown. The creep failure of the vessel wall was simulated with 1-D model, which can consider the rapid temperature gradient over the wall thickness during the ex-vessel cooling. From the calculation results, both the coolant temperature and the total amount of coolant mass injected into the cavity are known to be the important factors in determining the time period to keep the external vessel cool. Therefore, a long-term strategy to keep the coolant temperature subcooled throughout the transient is suggested to sustain or prolong the effect of external vessel cooling. Also, it is expected that to keep the primary side at low pressure and to perform the ex-vessel flooding be the essential conditions to sustain the vessel integrity. From MELCOR, the penetration failure always occurs after relocation regardless of the RCS pressure or availability of the external vessel cooling. Therefore, It is expected that the improvement of the model for the penetration tube failure will be necessary

  2. The evaluation of pressure effects on the ex-vessel cooling for KNGR with MELCOR

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hwa; Park, Soo Yong; Kim, Dong Ha

    2001-03-01

    In this report, the effect of external vessel cooling on debris coolability and vessel integrity for the KNGR were examined from the two typical pressure range of high(170 bar) and low(5 bar)case using the lower plenum model in MELCOR1.8.4. As the conditions of these calculations, 80 ton of debris was relocated simultaneously into the lower vessel head and the debris relocation temperature from the core region was 2700 K. The decay heat has been assumed to be that of one hour after reactor shutdown. The creep failure of the vessel wall was simulated with 1-D model, which can consider the rapid temperature gradient over the wall thickness during the ex-vessel cooling. From the calculation results, both the coolant temperature and the total amount of coolant mass injected into the cavity are known to be the important factors in determining the time period to keep the external vessel cool. Therefore, a long-term strategy to keep the coolant temperature subcooled throughout the transient is suggested to sustain or prolong the effect of external vessel cooling. Also, it is expected that to keep the primary side at low pressure and to perform the ex-vessel flooding be the essential conditions to sustain the vessel integrity. From MELCOR, the penetration failure always occurs after relocation regardless of the RCS pressure or availability of the external vessel cooling. Therefore, It is expected that the improvement of the model for the penetration tube failure will be necessary.

  3. Confinement Vessel Assay System: Design and Implementation Report

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Gomez, Cipriano D.; Miko, David K.; Salazar, William R.; Stange, Sy; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1- to 2-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. We have developed a neutron assay system for the purposes of Materials Control and Accountability (MC and A) measurements of the vessel prior to and after cleanout. We present our approach to confronting the challenges in designing, building, and testing such a system. The system was designed to meet a set of functional and operational requirements. A Monte Carlo model was developed to aid in optimizing the detector design as well as to predict the systematic uncertainty associated with confinement vessel measurements. Initial testing was performed to optimize and determine various measurement parameters, and then the system was characterized using 252 Cf placed a various locations throughout the measurement system. Measurements were also performed with a 252 Cf source placed inside of small steel and HDPE shells to study the effect of moderation. These measurements compare favorably with their MCNPX model equivalent, making us confident that we can rely on the Monte Carlo simulation to predict the systematic uncertainty due to variations in response to material that may be localized at different points within a vessel.

  4. Prestressed concrete vessels suitable for helium high temperature reactors

    International Nuclear Information System (INIS)

    Lockett, G.E.; Kinkead, A.N.

    1967-02-01

    In considering prestressed concrete vessels for use with helium cooled high temperature reactors, a number of new problems arise and projected designs involve new approaches and new solutions. These reactors, having high coolant outlet temperature from the core and relatively high power densities, can be built into compact designs which permit usefully high working pressures. Consequently, steam generators and circulating units tend to be small. Although circuit activity can be kept quite low with coated particle fuels, designs which involve entry for subsequent repair are not favoured, and coupled with the preferred aim of using fully shop fabricated units within the designs with removable steam generators which involve no tube welding inside the vessel. A particular solution uses a number of slim cylindrical assemblies housed in the wall of the pressure vessel and this vessel design concept is presented. The use of helium requires very high sealing standards and one of the important requirements is a vessel design which permits leak testing during construction, so that a repair seal can be made to any faulty part in a liner seam. Very good demountable joint seals can be made without particular difficulty and Dragon experience is used to provide solutions which are suitable for prestressed concrete vessel penetrations. The concept layout is given of a vessel meeting these requirements; the basis of design is outlined and special features of importance discussed. (author)

  5. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    An apparatus is described for sealing a cold leg nozzle of a nuclear reactor pressure vessel from a remote location comprising: at least one sealing plug for mechanically sealing the nozzle from the inside of the reactor pressure vessel. The sealing plug includes a plate and a cone assembly having an end part receptive in the nozzle, the plate being axially moveable relative to the cone assembly. The plate and cone assembly have confronting bevelled edges defining an opening therebetween. A primary O-ring is disposed about the opening and is supported on the bevelled edges, the plate being guidably mounted to the cone assembly for movement toward the cone assembly to radially expand the primary O-ring into sealing engagement with the nozzle. A means is included for providing relative movement between the outer plate and the cone assembly

  6. Mobile nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Thompson, R.E.; Spurrier, F.R.; Jones, A.R.

    1978-01-01

    A containment vessel for use in mobile nuclear reactor installations is described. The containment vessel completely surrounds the entire primary system, and is located as close to the reactor primary system components as is possible in order to minimize weight. In addition to being designed to withstand a specified internal pressure, the containment vessel is also designed to maintain integrity as a containment vessel in case of a possible collision accident

  7. Reactor vessel stud closure system

    International Nuclear Information System (INIS)

    Spiegelman, S.R.; Salton, R.B.; Beer, R.W.; Malandra, L.J.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner apparatus for enabling the loosening or tightening of a stud nut on a reactor vessel stud. The apparatus is adapted to engage the vessel stud by closing a gripper around an upper end of the vessel stud when the apparatus is seated on the stud. Upon lifting the apparatus, the gripper releases the vessel stud so that the apparatus can be removed

  8. Design and implementation of visual inspection system handed in tokamak flexible in-vessel robot

    International Nuclear Information System (INIS)

    Wang, Hesheng; Xu, Lifei; Chen, Weidong

    2016-01-01

    In-vessel viewing system (IVVS) is a fundamental tool among the remote handling systems for ITER, which is used to providing information on the status of the in-vessel components. The basic functional requirement of in-vessel visual inspection system is to perform a fast intervention with adequate optical resolution. In this paper, we present the software and hardware solution, which is designed and implemented for tokamak in-vessel viewing system that installed on end-effector of flexible in-vessel robot working under vacuum and high temperature. The characteristic of our in-vessel viewing system consists of two parts: binocular heterogeneous vision inspection tool and first wall scene emersion based augment virtuality. The former protected with water-cooled shield is designed to satisfy the basic functional requirement of visual inspection system, which has the capacity of large field of view and high-resolution for detection precision. The latter, achieved by overlaying first wall tiles images onto virtual first wall scene model in 3D virtual reality simulation system, is designed for convenient, intuitive and realistic-looking visual inspection instead of viewing the status of first wall only by real-time monitoring or off-line images sequences. We present the modular division of system, each of them in smaller detail, and go through some of the design choices according to requirements of in-vessel visual inspection task.

  9. Design and implementation of visual inspection system handed in tokamak flexible in-vessel robot

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hesheng; Xu, Lifei [Department of Automation, Shanghai Jiao Tong University, Shanghai 200240 (China); Key Laboratory of System Control and Information Processing, Ministry of Education of China (China); Chen, Weidong, E-mail: wdchen@sjtu.edu.cn [Department of Automation, Shanghai Jiao Tong University, Shanghai 200240 (China); Key Laboratory of System Control and Information Processing, Ministry of Education of China (China)

    2016-05-15

    In-vessel viewing system (IVVS) is a fundamental tool among the remote handling systems for ITER, which is used to providing information on the status of the in-vessel components. The basic functional requirement of in-vessel visual inspection system is to perform a fast intervention with adequate optical resolution. In this paper, we present the software and hardware solution, which is designed and implemented for tokamak in-vessel viewing system that installed on end-effector of flexible in-vessel robot working under vacuum and high temperature. The characteristic of our in-vessel viewing system consists of two parts: binocular heterogeneous vision inspection tool and first wall scene emersion based augment virtuality. The former protected with water-cooled shield is designed to satisfy the basic functional requirement of visual inspection system, which has the capacity of large field of view and high-resolution for detection precision. The latter, achieved by overlaying first wall tiles images onto virtual first wall scene model in 3D virtual reality simulation system, is designed for convenient, intuitive and realistic-looking visual inspection instead of viewing the status of first wall only by real-time monitoring or off-line images sequences. We present the modular division of system, each of them in smaller detail, and go through some of the design choices according to requirements of in-vessel visual inspection task.

  10. Myocytes of chorionic vessels from placentas with meconium-associated vascular necrosis exhibit apoptotic markers.

    Science.gov (United States)

    King, Erin L; Redline, Raymond W; Smith, Steven D; Kraus, Frederick T; Sadovsky, Yoel; Nelson, D Michael

    2004-04-01

    Meconium-associated vascular necrosis (MAVN) is a histological abnormality of human placental chorionic vessels that is associated with poor neonatal outcome. We tested the hypothesis that MAVN shows apoptosis in the walls of chorionic vessels. Archival placental specimens with MAVN (n = 5) were compared with specimens from uncomplicated pregnancies at term (n = 5) and from placentas with intense chorionic vasculitis associated with acute chorioamnionitis with (n = 5) or without (n = 5) a clinical history of meconium in the amniotic fluid. Sections from all placentas were processed by the TUNEL method, and 2 observers who were blinded to specimen diagnosis quantified the immunofluorescent TUNEL staining in both the amnion-facing and villous-facing walls of the larger chorionic vessels in each specimen. Compared with the other 3 groups, only the amnion-facing wall of chorionic vessels in MAVN showed a significantly greater number of apoptotic cells. This was verified by morphological criteria and caspase 3 staining. There were limited or no detectable TUNEL-stained cells in either the villous-facing walls of vessels in the MAVN specimens or in any of the vessels of the placentas from uncomplicated pregnancies. There was a negligible level of apoptosis in chorionic vessels of placentas with intense chorionic vasculitis, with or without meconium, despite the inflammatory response or presence of meconium. We conclude that apoptosis contributes to the pathophysiology of MAVN.

  11. Physico-Chemistry and Corium Properties for In-Vessel Retention

    International Nuclear Information System (INIS)

    Froment, K.; Seiler, J.M.; Gueneau, C.; Dauvois, V.; Barbier, F.; Bellon, M.; Tourasse, M.; Ducros, G.; Cognet, G.; Sudreau, F.

    1999-01-01

    This paper focuses on some important aspects of consequences of material behaviour and interactions on in-vessel retention capabilities. It discusses the behaviour of corium oxide mixtures at elevated temperatures (miscibility gap and density effects, separation due to density effects in the solid-liquid mixture according to the analysis of the Rasplav experiment results), and then the interaction between metallic layer and vessel wall (physical-chemical interaction of corium with the carbon steel vessel wall, migration of low melting point metallic elements in the solid vessel wall). It proposes a mode for the calculation of melt viscosity (liquid phase viscosity and viscosity in the solidification range), addresses the issue of barium release and residual power and of distribution of the residual power in an oxidic corium

  12. A continuum damage analysis of hydrogen attack in 2.25 Cr-1Mo vessel

    DEFF Research Database (Denmark)

    van der Burg, M.W.D.; van der Giessen, E.; Tvergaard, Viggo

    1998-01-01

    A micromechanically based continuum damage model is presented to analyze the stress, temperature and hydrogen pressure dependent material degradation process termed hydrogen attack, inside a pressure vessel. Hydrogen attack (HA) is the damage process of grain boundary facets due to a chemical...... reaction of carbides with hydrogen, thus forming cavities with high pressure methane gas. Driven by the methane gas pressure, the cavities grow, while remote tensile stresses can significantly enhance the cavitation rate. The damage model gives the strain-rate and damage rate as a function...... of the temperature, hydrogen pressure and applied stresses. The model is applied to study HA in a vessel wall, where nonuniform distributions of hydrogen pressure, temperature and stresses result in a nonuniform damage distribution over the vessel wall. Stresses inside the vessel wall first tend to accelerate...

  13. Reactor pressure vessel steels

    International Nuclear Information System (INIS)

    Van De Velde, J.; Fabry, A.; Van Walle, E.; Chaouuadi, R.

    1998-01-01

    Research and development activities related to reactor pressure vessel steels during 1997 are reported. The objectives of activities of the Belgian Nuclear Research Centre SCK/CEN in this domain are: (1) to develop enhanced surveillance concepts by applying micromechanics and fracture-toughness tests to small specimens, and by performing damage modelling and microstructure characterization; (2) to demonstrate a methodology on a broad database; (3) to achieve regulatory acceptance and industrial use

  14. Reactor Pressure Vessel Steels

    Energy Technology Data Exchange (ETDEWEB)

    Van de Velde, J.; Fabry, A.; Van Walle, E.; Chaoudi, R

    1998-07-01

    SCK-CEN's R and D programme on Reactor Pressure Vessel (RPV) Steels in performed in support of the RVP integrity assessment. Its main objectives are: (1) to develop enhanced surveillance concepts by applying micromechanics and fracture-toughness tests to small specimens, and by performing damage modelling and microstructure characterization; (2) to demonstrate the applied methodology on a broad database; (3) to achieve regulatory acceptance and industrial use. Progress and achievements in 1999 are reported.

  15. Blood Vessels in Allotransplantation.

    Science.gov (United States)

    Abrahimi, P; Liu, R; Pober, J S

    2015-07-01

    Human vascularized allografts are perfused through blood vessels composed of cells (endothelium, pericytes, and smooth muscle cells) that remain largely of graft origin and are thus subject to host alloimmune responses. Graft vessels must be healthy to maintain homeostatic functions including control of perfusion, maintenance of permselectivity, prevention of thrombosis, and participation in immune surveillance. Vascular cell injury can cause dysfunction that interferes with these processes. Graft vascular cells can be activated by mediators of innate and adaptive immunity to participate in graft inflammation contributing to both ischemia/reperfusion injury and allograft rejection. Different forms of rejection may affect graft vessels in different ways, ranging from thrombosis and neutrophilic inflammation in hyperacute rejection, to endothelialitis/intimal arteritis and fibrinoid necrosis in acute cell-mediated or antibody-mediated rejection, respectively, and to diffuse luminal stenosis in chronic rejection. While some current therapies targeting the host immune system do affect graft vascular cells, direct targeting of the graft vasculature may create new opportunities for preventing allograft injury and loss. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  16. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomenology of radiation-induced changes in blood vessels are systematized and authors' experience is generalized. Modern concepts about processes leading to vessel structure injury after irradiation is critically analyzed. Special attention is paid to reparation and compensation of X-ray vessel injury, consideration of which is not yet sufficiently elucidated in literature

  17. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  18. Processing vessel for high level radioactive wastes

    International Nuclear Information System (INIS)

    Maekawa, Hiromichi

    1998-01-01

    Upon transferring an overpack having canisters containing high level radioactive wastes sealed therein and burying it into an underground processing hole, an outer shell vessel comprising a steel plate to be fit and contained in the processing hole is formed. A bury-back layer made of dug earth and sand which had been discharged upon forming the processing hole is formed on the inner circumferential wall of the outer shell vessel. A buffer layer having a predetermined thickness is formed on the inner side of the bury-back layer, and the overpack is contained in the hollow portion surrounded by the layer. The opened upper portion of the hollow portion is covered with the buffer layer and the bury-back layer. Since the processing vessel having a shielding performance previously formed on the ground, the state of packing can be observed. In addition, since an operator can directly operates upon transportation and burying of the high level radioactive wastes, remote control is no more necessary. (T.M.)

  19. Design of High Temperature Reactor Vessel Using ANSYS Software

    International Nuclear Information System (INIS)

    Bandriyana; Kasmudin

    2003-01-01

    Design calculation and evaluation of material strength for high temperature reactor vessel based on the design of HTR-10 high temperature reactor vessel were carried out by using the ANSYS 5.4 software. ANSYS software was applied to calculate the combined load from thermal and pressure load. Evaluation of material strength was performed by calculate and determine the distribution of temperature, stress and strain in the thickness direction of vessel, and compared with its material strength for designed. The calculation was based on the inner wall temperature of vessel of 600 o C and the outer temperature of 500 and 600 o C. Result of calculation gave the maximum stress for outer temperature of 600 o C was 288 N/ mm 2 and strain of 0.000187. For outer temperature of 500 o C the maximum stress was 576 N/ mm 2 and strain of 0.003. Based on the analysis result, the material of steel SA 516-70 with limited stress for design of 308 N/ mm 2 can be used for vessel material with outer wall temperature of 600 o C

  20. Method of transferring regular shaped vessel into cell

    International Nuclear Information System (INIS)

    Murai, Tsunehiko.

    1997-01-01

    The present invention concerns a method of transferring regular shaped vessels from a non-contaminated area to a contaminated cell. A passage hole for allowing the regular shaped vessels to pass in the longitudinal direction is formed to a partitioning wall at the bottom of the contaminated cell. A plurality of regular shaped vessel are stacked in multiple stages in a vertical direction from the non-contaminated area present below the passage hole, allowed to pass while being urged and transferred successively into the contaminated cell. As a result, since they are transferred while substantially closing the passage hole by the regular shaped vessels, radiation rays or contaminated materials are prevented from discharging from the contaminated cell to the non-contaminated area. Since there is no requirement to open/close an isolation door frequently, the workability upon transfer can be improved remarkably. In addition, the sealing member for sealing the gap between the regular shaped vessel passing through the passage hole and the partitioning wall of the bottom is disposed to the passage hole, the contaminated materials in the contaminated cells can be prevented from discharging from the gap to the non-contaminated area. (N.H.)

  1. Nuclear reactor installation with outer shell enclosing a primary pressure vessel

    International Nuclear Information System (INIS)

    1975-01-01

    The high temperature nuclear reactor installation described includes a fluid cooled nuclear heat source, a primary pressure vessel containing the heat source, an outer shell enclosing the primary pressure vessel and acting as a secondary means of containment for this vessel against outside projectiles. Multiple auxiliary equipment points are arranged outside the outer shell which comprises a part of a lower wall around the primary pressure vessel, an annular part integrated in the lower wall and extending outwards as from this wall and an upper part integrated in the annular part and extending above this annular part and above the primary pressure vessel. The annular part and the primary pressure vessel are formed with vertical penetrations which can be closed communicating respectively with the auxiliary equipment points and with inside the pressure vessel whilst handling gear is provided in the upper part for vertically raising reactor components through these penetrations and for transporting them over the annular part and over the primary pressure vessel [fr

  2. Combining endoscopes with PIV and digital holography for the study of vessel model mechanics

    International Nuclear Information System (INIS)

    Arévalo, Laura; Palero, Virginia; Andrés, Nieves; Arroyo, M P; Lobera, Julia

    2015-01-01

    In this work traditional fluid and solid mechanics measurement techniques have been combined with endoscopes for the study of blood vessel models’ mechanical properties. Endoscopes have been used as the imaging part of a high-speed PIV system to obtain the velocity field in a vessel model immersed in a container with a refractive index-matching liquid. In this way, we take advantage of the fact that the endoscope tip can be immersed in liquid. Endoscopes have also been used as the imaging and illuminating part of a digital holographic set-up for wall deformation measurement. The novelty of this work is that only one endoscope was used for illuminating and observing the vessel model, using the endoscope’s own illuminating system as the illumination source. The performance of endoscopes in different vessel models has been tested. The results of flow velocity and wall deformation in the different blood vessel models are presented. (paper)

  3. Multi-vendor, multicentre comparison of contrast-enhanced SSFP and T2-STIR CMR for determining myocardium at risk in ST-elevation myocardial infarction

    Science.gov (United States)

    Nordlund, David; Klug, Gert; Heiberg, Einar; Koul, Sasha; Larsen, Terje H.; Hoffmann, Pavel; Metzler, Bernhard; Erlinge, David; Atar, Dan; Aletras, Anthony H.; Carlsson, Marcus; Engblom, Henrik; Arheden, Håkan

    2016-01-01

    Aims Myocardial salvage, determined by cardiac magnetic resonance imaging (CMR), is used as end point in cardioprotection trials. To calculate myocardial salvage, infarct size is related to myocardium at risk (MaR), which can be assessed by T2-short tau inversion recovery (T2-STIR) and contrast-enhanced steady-state free precession magnetic resonance imaging (CE-SSFP). We aimed to determine how T2-STIR and CE-SSFP perform in determining MaR when applied in multicentre, multi-vendor settings. Methods and results A total of 215 patients from 17 centres were included after percutaneous coronary intervention (PCI) for ST-elevation myocardial infarction. CMR was performed within 1–8 days. These patients participated in the MITOCARE or CHILL-MI cardioprotection trials. Additionally, 8 patients from a previous study, imaged 1 day post-CMR, were included. Late gadolinium enhancement, T2-STIR, and CE-SSFP images were acquired on 1.5T MR scanners (Philips, Siemens, or GE). In 65% of the patients, T2-STIR was of diagnostic quality compared with 97% for CE-SSFP. In diagnostic quality images, there was no difference in MaR by T2-STIR and CE-SSFP (bias: 0.02 ± 6%, P = 0.96, r2 = 0.71, P < 0.001), or between treatment and control arms. No change in size or quality of MaR nor ability to identify culprit artery was seen over the first week after the acute event (P = 0.44). Conclusion In diagnostic quality images, T2-STIR and CE-SSFP provide similar estimates of MaR, were constant over the first week, and were not affected by treatment. CE-SSFP had a higher degree of diagnostic quality images compared with T2 imaging for sequences from two out of three vendors. Therefore, CE-SSFP is currently more suitable for implementation in multicentre, multi-vendor clinical trials. PMID:27002140

  4. Fabrication of toroidal composite pressure vessels. Final report

    International Nuclear Information System (INIS)

    Dodge, W.G.; Escalona, A.

    1996-01-01

    A method for fabricating composite pressure vessels having toroidal geometry was evaluated. Eight units were fabricated using fibrous graphite material wrapped over a thin-walled aluminum liner. The material was wrapped using a machine designed for wrapping, the graphite material was impregnated with an epoxy resin that was subsequently thermally cured. The units were fabricated using various winding patterns. They were hydrostatically tested to determine their performance. The method of fabrication was demonstrated. However, the improvement in performance to weight ratio over that obtainable by an all metal vessel probably does not justify the extra cost of fabrication

  5. Conformable pressure vessel for high pressure gas storage

    Science.gov (United States)

    Simmons, Kevin L.; Johnson, Kenneth I.; Lavender, Curt A.; Newhouse, Norman L.; Yeggy, Brian C.

    2016-01-12

    A non-cylindrical pressure vessel storage tank is disclosed. The storage tank includes an internal structure. The internal structure is coupled to at least one wall of the storage tank. The internal structure shapes and internally supports the storage tank. The pressure vessel storage tank has a conformability of about 0.8 to about 1.0. The internal structure can be, but is not limited to, a Schwarz-P structure, an egg-crate shaped structure, or carbon fiber ligament structure.

  6. Materials requirements for the ITER vacuum vessel and in-vessel components - approaching the construction phase

    International Nuclear Information System (INIS)

    Barabash, V.; Ioki, K.; Pick, M.; Girard, J.P.; Merola, M.

    2007-01-01

    Full text of publication follows: The ITER activities are fully devoted toward its construction. In accordance with the ITER integrated project schedule, the procurement specifications for the manufacturing of the Vacuum Vessel should be prepared by March 2008 and the procurement specifications for the in-vessel components (first wall/blanket, divertor) by 2009. To update the design, considering design and technology evolution, the ITER Design Review has been launched. Among the various topics being discussed are the important issues related to selection of materials, material procurement, and assessment of performance during operation. The main requirements related to materials for the vacuum vessel and the in-vessel components are summarized in the paper. The specific licensing requirements are to be followed for structural materials of pressure and nuclear pressure equipment components for construction of ITER. In addition, the procurements in ITER will be done mostly 'in-kind' and it is assumed that materials for these components will be produced by different Parties. However, in accordance with the regulatory requirements and quality requirements for operation, common specifications and the general rules to fulfill these requirements are to be adopted. For some ITER components (e.g. first wall, divertor high heat flux components), the ultimate qualification of the joining technologies (Be/Cu, SS/Cu, CFC/Cu, W/Cu) is under final evaluation. Successful accomplishment of the qualification program will allow to proceed with procurements of the components for ITER. The criteria for acceptance of these components and materials after manufacturing are described and the main results will be reported. Additional materials issues, which come from the on-going manufacturing R and D program, will be also described. Finally, further materials activity during the construction phase, needs for final qualification and acceptance of materials are discussed. (authors)

  7. Customizable engineered blood vessels using 3D printed inserts.

    Science.gov (United States)

    Pinnock, Cameron B; Meier, Elizabeth M; Joshi, Neeraj N; Wu, Bin; Lam, Mai T

    2016-04-15

    Current techniques for tissue engineering blood vessels are not customizable for vascular size variation and vessel wall thickness. These critical parameters vary widely between the different arteries in the human body, and the ability to engineer vessels of varying sizes could increase capabilities for disease modeling and treatment options. We present an innovative method for producing customizable, tissue engineered, self-organizing vascular constructs by replicating a major structural component of blood vessels - the smooth muscle layer, or tunica media. We utilize a unique system combining 3D printed plate inserts to control construct size and shape, and cell sheets supported by a temporary fibrin hydrogel to encourage cellular self-organization into a tubular form resembling a natural artery. To form the vascular construct, 3D printed inserts are adhered to tissue culture plates, fibrin hydrogel is deposited around the inserts, and human aortic smooth muscle cells are then seeded atop the fibrin hydrogel. The gel, aided by the innate contractile properties of the smooth muscle cells, aggregates towards the center post insert, creating a tissue ring of smooth muscle cells. These rings are then stacked into the final tubular construct. Our methodology is robust, easily repeatable and allows for customization of cellular composition, vessel wall thickness, and length of the vessel construct merely by varying the size of the 3D printed inserts. This platform has potential for facilitating more accurate modeling of vascular pathology, serving as a drug discovery tool, or for vessel repair in disease treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Assessment of reactor vessel integrity (ARVI)

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R. [Division of Nuclear Power Safety (NPS), Royal Institute of Technology (KTH), Drottning Kristinas Vaeg 33A, 10044 Stockholm (Sweden)]. E-mail: sehgal@ne.kth.se; Karbojian, A. [Division of Nuclear Power Safety (NPS), Royal Institute of Technology (KTH), Drottning Kristinas Vaeg 33A, 10044 Stockholm (Sweden); Giri, A. [Division of Nuclear Power Safety (NPS), Royal Institute of Technology (KTH), Drottning Kristinas Vaeg 33A, 10044 Stockholm (Sweden); Kymaelaeinen, O. [FortumEngNP (Finland); Bonnet, J.M. [CEA (France); Ikkonen, K. [Division of Nuclear Power Safety (NPS), Royal Institute of Technology (KTH), Drottning Kristinas Vaeg 33A, 10044 Stockholm (Sweden); Sairanen, R. [VTT (Finland); Bhandari, S. [FRAMATOME (France); Buerger, M. [USTUTT (Germany); Dienstbier, J. [NRI Rez (Czech Republic); Techy, Z. [VEIKI (Hungary); Theofanous, T. [UCSB (United States)

    2005-02-01

    The assessment of reactor vessel integrity (ARVI) project involved a total of nine organizations from Europe and USA. The work consisted of experiments and analysis development. The modeling activities in the area of structural analyses were focused on the support of EC-FOREVER experiments as well as on the exploitation of the data obtained from those experiments for modeling of creep deformation and the validation of the industry structural codes. Work was also performed for extension of melt natural convection analyses to consideration of stratification, and mixing (in the CFD codes). Other modeling activities were for (1) gap cooling CHF and (2) developing simple models for system code. Finally, the methodology and data was applied for the design of IVMR severe accident management scheme for VVER-440/213 plants. The work was broken up into five packages. They were divided into tasks, which were performed by different partners. The major experimental project continued was EC-FOREVER in which data was obtained on in-vessel melt pool coolability. In previous EC-FOREVER experiments data was obtained on melt pool natural convection and lower head creep failure and rupture. Those results obtained were related to the following issues: (1) multiaxial creep laws for different vessel steels (2) effects of penetrations, and (3) mode and location of lower head failure. The two EC-FOREVER tests reported here are related to (a) the effectiveness of gap cooling and (b) water ingression for in vessel melt coolability. Two other experimental projects were also conducted. One was the COPO experiments, which was concerned with the effects of stratification and metal layer on the thermal loads on the lower head wall during melt pool convection. The second experimental project was conducted at ULPU facility, which provided data and correlations of CHF due to the external cooling of the lower head.

  9. Dynamic properties of the Sulfolobus CRISPR/Cas and CRISPR/Cmr systems when challenged with vector-borne viral and plasmid genes and protospacers

    DEFF Research Database (Denmark)

    Guðbergsdóttir, Sóley Ruth; Deng, Ling; Chen, Zhengjun

    2011-01-01

    The adaptive immune CRISPR/Cas and CRISPR/Cmr systems of the crenarchaeal thermoacidophile Sulfolobus were challenged by a variety of viral and plasmid genes, and protospacers preceded by different dinucleotide motifs. The genes and protospacers were constructed to carry sequences matching...... individual spacers of CRISPR loci, and a range of mismatches were introduced. Constructs were cloned into vectors carrying pyrE/pyrF genes and transformed into uracil auxotrophic hosts derived from Sulfolobus solfataricus P2 or Sulfolobus islandicus REY15A. Most constructs, including those carrying different...... protospacer mismatches, yielded few viable transformants. These were shown to carry either partial deletions of CRISPR loci, covering a broad spectrum of sizes and including the matching spacer, or deletions of whole CRISPR/Cas modules. The deletions occurred independently of whether genes or protospacers...

  10. A CMR study of the effects of tissue edema and necrosis on left ventricular dyssynchrony in acute myocardial infarction: implications for cardiac resynchronization therapy

    Directory of Open Access Journals (Sweden)

    Manka Robert

    2012-07-01

    Full Text Available Abstract Background In acute myocardial infarction (AMI, both tissue necrosis and edema are present and both might be implicated in the development of intraventricular dyssynchrony. However, their relative contribution to transient dyssynchrony is not known. Cardiovascular magnetic resonance (CMR can detect necrosis and edema with high spatial resolution and it can quantify dyssynchrony by tagging techniques. Methods Patients with a first AMI underwent percutaneous coronary interventions (PCI of the infarct-related artery within 24 h of onset of chest pain. Within 5–7 days after the event and at 4 months, CMR was performed. The CMR protocol included the evaluation of intraventricular dyssynchrony by applying a novel 3D-tagging sequence to the left ventricle (LV yielding the CURE index (circumferential uniformity ratio estimate; 1 = complete synchrony. On T2-weighted images, edema was measured as high-signal (>2 SD above remote tissue along the LV mid-myocardial circumference on 3 short-axis images (% of circumference corresponding to the area-at-risk. In analogy, on late-gadolinium enhancement (LGE images, necrosis was quantified manually as percentage of LV mid-myocardial circumference on 3 short-axis images. Necrosis was also quantified on LGE images covering the entire LV (expressed as %LV mass. Finally, salvaged myocardium was calculated as the area-at-risk minus necrosis (expressed as % of LV circumference. Results After successful PCI (n = 22, 2 female, mean age: 57 ± 12y, peak troponin T was 20 ± 36ug/l and the LV ejection fraction on CMR was 41 ± 8%. Necrosis mass was 30 ± 10% and CURE was 0.91 ± 0.05. Edema was measured as 58 ± 14% of the LV circumference. In the acute phase, the extent of edema correlated with dyssynchrony (r2 = −0.63, p 2 = −0.19, p = 0.05. PCI resulted in salvaged myocardium of 27 ± 14%. LV dyssynchrony (=CURE decreased at 4 months from 0.91

  11. Large vessel involvement by IgG4-related disease

    Science.gov (United States)

    Perugino, Cory A.; Wallace, Zachary S.; Meyersohn, Nandini; Oliveira, George; Stone, James R.; Stone, John H.

    2016-01-01

    Abstract Objectives: IgG4-related disease (IgG4-RD) is an immune-mediated fibroinflammatory condition that can affect multiple organs and lead to tumefactive, tissue-destructive lesions. Reports have described inflammatory aortitis and periaortitis, the latter in the setting of retroperitoneal fibrosis (RPF), but have not distinguished adequately between these 2 manifestations. The frequency, radiologic features, and response of vascular complications to B cell depletion remain poorly defined. We describe the clinical features, radiology findings, and treatment response in a cohort of 36 patients with IgG4-RD affecting large blood vessels. Methods: Clinical records of all patients diagnosed with IgG4-RD in our center were reviewed. All radiologic studies were reviewed. We distinguished between primary large blood vessel inflammation and secondary vascular involvement. Primary involvement was defined as inflammation in the blood vessel wall as a principal focus of disease. Secondary vascular involvement was defined as disease caused by the effects of adjacent inflammation on the blood vessel wall. Results: Of the 160 IgG4-RD patients in this cohort, 36 (22.5%) had large-vessel involvement. The mean age at disease onset of the patients with large-vessel IgG4-RD was 54.6 years. Twenty-eight patients (78%) were male and 8 (22%) were female. Thirteen patients (36%) had primary IgG4-related vasculitis and aortitis with aneurysm formation comprised the most common manifestation. This affected 5.6% of the entire IgG4-RD cohort and was observed in the thoracic aorta in 8 patients, the abdominal aorta in 4, and both the thoracic and abdominal aorta in 3. Three of these aneurysms were complicated by aortic dissection or contained perforation. Periaortitis secondary to RPF accounted for 27 of 29 patients (93%) of secondary vascular involvement by IgG4-RD. Only 5 patients demonstrated evidence of both primary and secondary blood vessel involvement. Of those treated with

  12. Pressure vessel lid

    International Nuclear Information System (INIS)

    Schoening, J.; Elter, C.; Becker, G.; Pertiller, S.

    1986-01-01

    The invention concerns a lid for closing openings in reactor pressure vessels containing helium, which is made as a circular casting with hollow spaces and a flat floor and is set on the opening and kept down. It consists of helium-tight metal cast material with sufficient temperature resistance. There are at least two concentric heat resistant seals let into the bottom of the lid. The bottom is in immediate contact with the container atmosphere and has hollow spaces in its inside in the area opposite to the opening. (orig./HP) [de

  13. [Small vessel cerebrovascular disease].

    Science.gov (United States)

    Cardona Portela, P; Escrig Avellaneda, A

    2018-05-09

    Small vessel vascular disease is a spectrum of different conditions that includes lacunar infarction, alteration of deep white matter, or microbleeds. Hypertension is the main risk factor, although the atherothrombotic lesion may be present, particularly in large-sized lacunar infarctions along with other vascular risk factors. MRI findings are characteristic and the lesions authentic biomarkers that allow differentiating the value of risk factors and defining their prognostic value. Copyright © 2018 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Cell tracking and therapy evaluation of bone marrow monocytes and stromal cells using SPECT and CMR in a canine model of myocardial infarction

    Directory of Open Access Journals (Sweden)

    Merrifield Peter

    2009-04-01

    Full Text Available Abstract Background The clinical application of stem cell therapy for myocardial infarction will require the development of methods to monitor treatment and pre-clinical assessment in a large animal model, to determine its effectiveness and the optimum cell population, route of delivery, timing, and flow milieu. Objectives To establish a model for a in vivo tracking to monitor cell engraftment after autologous transplantation and b concurrent measurement of infarct evolution and remodeling. Methods We evaluated 22 dogs (8 sham controls, 7 treated with autologous bone marrow monocytes, and 7 with stromal cells using both imaging of 111Indium-tropolone labeled cells and late gadolinium enhancement CMR for up to12 weeks after a 3 hour coronary occlusion. Hearts were also examined using immunohistochemistry for capillary density and presence of PKH26 labeled cells. Results In vivo Indium imaging demonstrated an effective biological clearance half-life from the injection site of ~5 days. CMR demonstrated a pattern of progressive infarct shrinkage over 12 weeks, ranging from 67–88% of baseline values with monocytes producing a significant treatment effect. Relative infarct shrinkage was similar through to 6 weeks in all groups, following which the treatment effect was manifest. There was a trend towards an increase in capillary density with cell treatment. Conclusion This multi-modality approach will allow determination of the success and persistence of engraftment, and a correlation of this with infarct size shrinkage, regional function, and left ventricular remodeling. There were overall no major treatment effects with this particular model of transplantation immediately post-infarct.

  15. Analysis code for pressure in reactor containment vessel of ATR. CONPOL

    International Nuclear Information System (INIS)

    1997-08-01

    For the evaluation of the pressure and temperature in containment vessels in the events which are classified in the abnormal change of pressure, atmosphere and others in reactor containment vessels in accident among the safety evaluation events of the ATR, the analysis code for the pressure in reactor containment vessels CONPOL is used. In this report, the functions of the analysis code and the analysis model are shown. By using this analysis code, the rise of the pressure and temperature in a containment vessel is evaluated when loss of coolant accident occurs, and high temperature, high pressure coolant flows into it. This code possesses the functions of computing blow-down quantity and heat dissipation from reactor cooling facility, steam condensing heat transfer to containment vessel walls, and the cooling effect by containment vessel spray system. As for the analysis techniques, the models of reactor cooling system, containment vessel and steam discharge pool, and the computation models for the pressure and temperature in containment vessels, wall surface temperature, condensing heat transfer, spray condensation and blow-down are explained. The experimental analysis of the evaluation of the pressure and temperature in containment vessels at the time of loss of coolant accident is reported. (K.I.)

  16. Reconstruction of the full thickness chest wall defect. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Moriguchi, T; Sano, S; Ogawa, Y; Fujimori, Y [Kyoto Univ. (Japan). Faculty of Medicine; Abe, R

    1977-03-01

    To treat the chest wall defect following the postoperative radiotherapy for breast cancer, we used an island flap prepared from the opposite mammary region preserving the perforating vessels from the internal thoracic artery.

  17. Integrity of PWR pressure vessels during overcooling accidents

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Iskander, S.K.; Whitman, G.D.

    1982-01-01

    The reactor pressure vessel in a pressurized water reactor is normally subjected to temperatures and pressures that preclude propagation of sharp, crack-like defects that might exist in the wall of the vessel. However, there is a class of postulated accidents, referred to as overcooling accidents, that can subject the pressure vessel to severe thermal shock while the pressure is substantial. As a result of such accidents vessels containing high concentrations of copper and nickel, which enhance radiation embrittlement, may possess a potential for extensive propagation of preexistent inner surface flaws prior to the vessel's normal end of life. For the purpose of evaluating this problem a state-of-the-art fracture mechanics model was developed and has been used for conducting parametric analyses and for calculating several recorded PWR transients. Results of the latter analysis indicate that there may be some vessels that have a potential for failure today if subjected to a Rancho Seco (1978) or TMI-2 (1979) type transient. However, the calculational model may be excessively conservative, and this possibility is under investigation

  18. Integrity of PWR pressure vessels during overcooling accidents

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Iskander, S.K.; Whitman, G.D.

    1982-01-01

    The reactor pressure vessel in a pressurized water reactor is normally subjected to temperatures and pressures that preclude propagation of sharp, crack-like defects that might exist in the wall of the vessel. However, there is a class of postulated accidents, referred to as overcooling accidents, that can subject the pressure vessel to severe thermal shock while the pressure is substantial. As a result of such accidents, vessels containing high concentrations of copper and nickel, which enhance radiation embrittlement, may possess a potential for extensive propagation of preexistent inner surface flaws prior to the vessel's normal end of life. A state-of-the-art fracture-mechanics model was developed and has been used for conducting parametric analyses and for calculating several recorded PWR transients. Results of the latter analysis indicate that there may be some vessels that have a potential for failure in a few years if subjected to a Rancho Seco-type transient. However, the calculational model may be excessively conservative, and this possibility is under investigation

  19. GAREC analyses in Support of In-Vessel Retention Concept

    International Nuclear Information System (INIS)

    Azarian, G.; Gandrille, P.; Dumontet, A.; Grange; Barbier, F; Bellon, M.; Bordier, G.; Boulanger, F.; Cognet, G.; Gatt, J.M.; Humbert, J.M.; Laporte, T.; Lepareux, M.; Richard, P.; Robert, G.; Seiler, J.M.; Szabo, I.; Tourasse, M.; Valin, F.; Van Dorsselaere, J.P.

    1999-01-01

    The authors describe the analyses of the in-vessel retention capability which the GAREC group has performed for present and future French PWR designs. They present the reactor characteristics which are considered, describe the physical situations which are analysed and the relocation processes initiated by a corium flow, discuss the jet impacts, the debris formation and behaviour in the vessel lower head in a dry situation with absence of cooling, in wet situations in absence of external cooling, in wet situation with external cooling, in dry situation with external cooling. In this last case, they discuss the power dissipated in the corium, the molten salt behaviour, the heat flux distribution from the pool, the residual wall thickness, the heat flux distribution from the metal layer, the thermal-hydraulic aspects of water injection in the pool, the effects of crust instabilities, the external cooling, and the vessel mechanical behaviour. Then, they address the vapour explosion which may occur: mechanical loads leading to vessel failure in the cases of an eroded or non-eroded vessel, corium masses participating to the interaction (corium jets to the lower head, reflooding of corium pools with water). They finally briefly discuss the possible design improvements for in-vessel retention

  20. ITER vacuum vessel dynamic stress analysis of a disruption

    International Nuclear Information System (INIS)

    Riemer, B.W.; Conner, D.L.; Strickler, D.J.; Williamson, D.E.

    1994-01-01

    Dynamic stress analysis of the International Thermonuclear Experimental Reactor vacuum vessel loaded by disruption forces was performed. The deformation and stress results showed strong inertial effects when compared to static analyses. Maximum stress predicted dynamically was 300 MPa, but stress shown by static analysis from loads at the same point in time reached only 80 MPa. The analysis also provided a reaction load history in the vessel's supports which is essential in evaluating support design. The disruption forces were estimated by assuming a 25-MA plasma current decaying at 1 MA/ms while moving vertically. In addition to forces developed within the vessel, vertical loadings from the first wall/strong back assemblies and the divertor were applied to the vessel at their attachment points. The first 50 natural modes were also determined. The first mode's frequency was 6.0 Hz, and its shape is characterized by vertical displacement of the vessel inner leg. The predicted deformation of the vessel appeared similar to its first mode shape combined with radial contraction. Kinetic energy history from the analysis also correlated with the first mode frequency

  1. An automated vessel segmentation of retinal images using multiscale vesselness

    International Nuclear Information System (INIS)

    Ben Abdallah, M.; Malek, J.; Tourki, R.; Krissian, K.

    2011-01-01

    The ocular fundus image can provide information on pathological changes caused by local ocular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. Automated analysis and interpretation of fundus images has become a necessary and important diagnostic procedure in ophthalmology. The extraction of blood vessels from retinal images is an important and challenging task in medical analysis and diagnosis. In this paper, we introduce an implementation of the anisotropic diffusion which allows reducing the noise and better preserving small structures like vessels in 2D images. A vessel detection filter, based on a multi-scale vesselness function, is then applied to enhance vascular structures.

  2. Comparison of usefulness of N-terminal pro-brain natriuretic peptide as an independent predictor of cardiac function among admission cardiac serum biomarkers in patients with anterior wall versus nonanterior wall ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    Science.gov (United States)

    Haeck, Joost D E; Verouden, Niels J W; Kuijt, Wichert J; Koch, Karel T; Van Straalen, Jan P; Fischer, Johan; Groenink, Maarten; Bilodeau, Luc; Tijssen, Jan G P; Krucoff, Mitchell W; De Winter, Robbert J

    2010-04-15

    The purpose of the present study was to determine the prognostic value of N-terminal pro-brain natriuretic peptide (NT-pro-BNP), among other serum biomarkers, on cardiac magnetic resonance (CMR) imaging parameters of cardiac function and infarct size in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. We measured NT-pro-BNP, cardiac troponin T, creatinine kinase-MB fraction, high-sensitivity C-reactive protein, and creatinine on the patients' arrival at the catheterization laboratory in 206 patients with ST-segment elevation myocardial infarction. The NT-pro-BNP levels were divided into quartiles and correlated with left ventricular function and infarct size measured by CMR imaging at 4 to 6 months. Compared to the lower quartiles, patients with nonanterior wall myocardial infarction in the highest quartile of NT-pro-BNP (> or = 260 pg/ml) more often had a greater left ventricular end-systolic volume (68 vs 39 ml/m(2), p pro-BNP level of > or = 260 pg/ml was the strongest independent predictor of left ventricular ejection fraction in patients with nonanterior wall myocardial infarction compared to the other serum biomarkers (beta = -5.8; p = 0.019). In conclusion, in patients with nonanterior wall myocardial infarction undergoing primary percutaneous coronary intervention, an admission NT-pro-BNP level of > or = 260 pg/ml was a strong, independent predictor of left ventricular function assessed by CMR imaging at follow-up. Our findings suggest that NT-pro-BNP, a widely available biomarker, might be helpful in the early risk stratification of patients with nonanterior wall myocardial infarction. Copyright 2010 Elsevier Inc. All rights reserved.

  3. 1D/2D analyses of the lower head vessel in contact with high temperature melt

    International Nuclear Information System (INIS)

    Chang, Jong Eun; Cho, Jae Seon; Suh, Kune Y.; Chung, Chang H.

    1998-01-01

    One- and two-dimensional analyses were performed for the ceramic/metal melt and the vessel to interpret the temperature history of the outer surface of the vessel wall measured from typical Al 2 O 3 /Fe thermite melt tests LAVA (Lower-plenum Arrested Vessel Attack) spanning heatup and cooldown periods. The LAVA tests were conducted at the Korea Atomic Energy Research Institute (KAERI) during the process of high temperature molten material relocation from the delivery duct down into the water in the test vessel pressurized to 2.0 MPa. Both analyses demonstrated reasonable predictions of the temperature history of the LHV (Lower Head Vessel). The comparison sheds light on the thermal hydraulic and material behavior of the high temperature melt within the hemispherical vessel

  4. Targeting Therapy Resistant Tumor Vessels

    Science.gov (United States)

    2008-08-01

    Morris LS. Hysterectomy vs. resectoscopic endometrial ablation for the control of abnormal uterine bleeding . A cost-comparative study. J Reprod Med 1994;39...after the antibody treatment contain a pericyte coat, vessel architecture is normal, the diameter of the vessels is smaller (dilated, abnormal vessels...involvement of proteases from inflammatory mast cells and functionally abnormal (Carmeliet and Jain, 2000; Pasqualini (Coussens et al., 1999) and other bone

  5. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  6. Americium behaviour in plastic vessels

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.; Abelairas, A.

    2010-01-01

    The adsorption of 241 Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of 241 Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of 241 Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  7. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  8. Americium behaviour in plastic vessels.

    Science.gov (United States)

    Legarda, F; Herranz, M; Idoeta, R; Abelairas, A

    2010-01-01

    The adsorption of (241)Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of (241)Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of (241)Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification. Copyright 2009 Elsevier Ltd. All rights reserved.

  9. Iter in vessel viewing system design and assessment activities

    Energy Technology Data Exchange (ETDEWEB)

    Neri, C., E-mail: carlo.neri@enea.it [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Costa, P.; Ferri De Collibus, M.; Florean, M.; Mugnaini, G.; Pillon, M.; Pollastrone, F.; Rossi, P. [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy)

    2011-10-15

    The In Vessel Viewing System (IVVS) is fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A prototype of a laser In Vessel Viewing and ranging System was developed and tested at ENEA laboratories in Frascati under EFDA task agreements, it is able to perform sub-millimetric bi-dimensional and three-dimensional images inside ITER during maintenance procedure allowing the evaluation of the state and damages of the in-vessel surface. The present prototype has been designed to operate under room conditions and starting from springtime 2009 a Grant with F4E is in progress for the design and the assessment of the IVVS system for ITER, keeping in account all the environmental conditions and constraints.

  10. CT and MR angiographic findings in dissection of cervical vessels

    International Nuclear Information System (INIS)

    Link, J.; Brinkmann, G.; Heuser, K.; Heller, M.

    1996-01-01

    Purpose: To determine the usefulness of CT angiography (CTA) and MR angiography (MRA) for evaluation of dissection in cervical vessels. Material and methods: Dissection of cervical vessels was revealed by conventional angiography in 4 patients (two female, two male) of 30-62 years of age. Dissection was located in the carotid artery (n=3) and in the vertebral artery (n=1). In two patients CTA and in two patients MRA was performed. Results: Diagnosis of dissection was possible by CTA (internal carotid artery: n=2) and by MRA (internal carotid artery and vertebral artery). Imaging of the dissection membrane of the vessel wall was possible in one case with MRA. Conclusion: CT and MR angiography was successful for detection of typical morphology of dissection in all cases. If results in a greater number can be obtained it seems to be conceivable that both methods can be used in primary diagnosis. (orig.) [de

  11. Optimized Baking of the DIII-D Vessel

    International Nuclear Information System (INIS)

    Anderson, P.M.; Kellman, A.G.

    1999-01-01

    The DIII-D tokamak vacuum vessel baking system is used to heat the vessel walls and internal hardware to an average temperature of 350 C to allow rapid conditioning of the vacuum surfaces. The system combines inductive heating and a circulating hot air system to provide rapid heating with temperature uniformity required by stress considerations. In recent years, the time to reach 350 C had increased from 9 hrs to 14 hrs. To understand and remedy this sluggish heating rate, an evaluation of the baking system was recently performed. The evaluation indicated that the mass of additional in-vessel hardware (50% increase in mass) was primarily responsible. This paper reports on this analysis and the results of the addition of an electric air heater and procedural changes that have been implemented. Preliminary results indicate that the time to 350 C has been decreased to 4.5 hours and the temperature uniformity has improved

  12. [Large vessel vasculitides].

    Science.gov (United States)

    Morović-Vergles, Jadranka; Puksić, Silva; Gracanin, Ana Gudelj

    2013-01-01

    Large vessel vasculitis includes Giant cell arteritis and Takayasu arteritis. Giant cell arteritis is the most common form of vasculitis affect patients aged 50 years or over. The diagnosis should be considered in older patients who present with new onset of headache, visual disturbance, polymyalgia rheumatica and/or fever unknown cause. Glucocorticoides remain the cornerstone of therapy. Takayasu arteritis is a chronic panarteritis of the aorta ant its major branches presenting commonly in young ages. Although all large arteries can be affected, the aorta, subclavian and carotid arteries are most commonly involved. The most common symptoms included upper extremity claudication, hypertension, pain over the carotid arteries (carotidynia), dizziness and visual disturbances. Early diagnosis and treatment has improved the outcome in patients with TA.

  13. Reactor pressure vessel embrittlement

    International Nuclear Information System (INIS)

    1992-07-01

    Within the framework of the IAEA extrabudgetary programme on the Safety of WWER-440/230 NPPs, a list of safety issues requiring broad studies of generic interest have been agreed upon by an Advisory Group who met in Vienna in September 1990. The list was later revised in the light of the programme findings. The information on the status of the issues, and on the amount of work already completed and under way in the various countries, needs to be compiled. Moreover, an evaluation of what further work is required to resolve each one of the issues is also necessary. In view of this, the IAEA has started the preparation of a series of status reports on the various issues. This report on the generic safety issue ''Reactor Pressure Vessel Embrittlement'' presents a comprehensive survey of technical information available in the field and identifies those aspects which require further investigation. 39 refs, 21 figs, 4 tabs

  14. Reactor containment vessel

    International Nuclear Information System (INIS)

    Ochiai, Kanehiro; Hayagumo, Sunao; Morikawa, Matsuo.

    1981-01-01

    Purpose: To safety and simplify the structure in a reactor containment vessel. Constitution: Steam flow channels with steam jetting ports communicating to coolants are provided between a communication channel and coolants in a pressure suppression chamber. Upon loss of coolant accidents, pressure in a dry well will increase, then force downwards water in an annulus portion and further flow out the water through steam jetting ports into a suppression pool. Thus, the steam flow channel is filled with steams or airs present in the dry well, which are released through the steam jetting ports into the pressure suppression chamber. Even though water is violently vibrated owing to the upward movement of air bubbles and condensation of steam bubbles, the annular portion and the steam jetting ports are filled with steams or the like, direct dynamic loads onto the structures such as communication channels can be avoided. (J.P.N.)

  15. Coupled thermo-mechanical creep analysis for boiling water reactor pressure vessel lower head

    International Nuclear Information System (INIS)

    Villanueva, Walter; Tran, Chi-Thanh; Kudinov, Pavel

    2012-01-01

    Highlights: ► We consider a severe accident in a BWR with melt pool formation in the lower head. ► We study the influence of pool depth on vessel failure mode with creep analysis. ► There are two modes of failure; ballooning of vessel bottom and a localized creep. ► External vessel cooling can suppress creep and subsequently prevent vessel failure. - Abstract: In this paper we consider a hypothetical severe accident in a Nordic-type boiling water reactor (BWR) at the stage of relocation of molten core materials to the lower head and subsequent debris bed and then melt pool formation. Nordic BWRs rely on reactor cavity flooding as a means for ex-vessel melt coolability and ultimate termination of the accident progression. However, different modes of vessel failure may result in different regimes of melt release from the vessel, which determine initial conditions for melt coolant interaction and eventually coolability of the debris bed. The goal of this study is to define if retention of decay-heated melt inside the reactor pressure vessel is possible and investigate modes of the vessel wall failure otherwise. The mode of failure is contingent upon the ultimate mechanical strength of the vessel structures under given mechanical and thermal loads and applied cooling measures. The influence of pool depth and respective transient thermal loads on the reactor vessel failure mode is studied with coupled thermo-mechanical creep analysis. Efficacy of control rod guide tube (CRGT) cooling and external vessel wall cooling as potential severe accident management measures is investigated. First, only CRGT cooling is considered in simulations revealing two different modes of vessel failure: (i) a ‘ballooning’ of the vessel bottom and (ii) a ‘localized creep’ concentrated within the vicinity of the top surface of the melt pool. Second, possibility of in-vessel retention with CRGT and external vessel cooling is investigated. We found that the external vessel

  16. ITER vacuum vessel, in vessel components and plasma facing materials

    International Nuclear Information System (INIS)

    Ioki, Kimihiro; Enoeda, M.; Federici, G.

    2007-01-01

    Design of the NB ports including duct liners under heat loads of the neutral beams has been developed. Design of the in-wall shielding has been developed in more details considering the supporting structure and the assembly method. The ferromagnetic inserts have previously not been installed in the outboard midplane region due to irregularity caused by the tangential ports for NB injection. Due to this configuration, the maximum ripple is relatively large (∝1 %) in a limited region of the plasma and the toroidal field flux lines fluctuate ∝10 mm in the FW region. To avoid these problems, additional ferromagnetic inserts are to be installed in the equatorial port region. Detailed studies were carried out on the ITER vacuum vessel to define appropriate codes and standards in the context of the ITER licensing in France. A set of draft documents regarding the ITER vacuum vessel structural code were prepared including an RCC-MR Addendum for the ITER VV with justified exceptions or modifications. The main deviation from the base Code is the extensive use of UT in lieu of radiography for the volumetric examination of all one-side access welds of the outer shell and field joint. The procurement allocation of blanket modules among 6 parties was fixed and the blanket module design has progressed in cooperation with parties. Fabrication of mock-ups for prequalification testing is under way and the tests will be performed in 2007-2008. Development of new beryllium materials is progressing in China and Russia. The ITER limiters will be installed in equatorial ports at two toroidal locations. The limiter plasma-facing surface protrudes ∝8 cm from the FW during the start-up and shutdown phase. In the new limiter concept, the limiters are retracted by ∝8 cm during the plasma flat top phase. This concept gives important advantages; (i) mitigation of the particle and heat loads due to disruptions, ELMs and blobs, (ii) improvement of the power coupling with the ICRH antenna

  17. Noninvasive detection of coronary artery wall thickening with age in healthy subjects using high resolution MRI with beat-to-beat respiratory motion correction.

    Science.gov (United States)

    Scott, Andrew D; Keegan, Jennifer; Mohiaddin, Raad H; Firmin, David N

    2011-10-01

    To demonstrate coronary artery wall thickening with age in a small healthy cohort using a highly efficient, reliable, and reproducible high-resolution MR technique. A 3D cross-sectional MR vessel wall images (0.7 × 0.7 × 3 mm resolution) with retrospective beat-to-beat respiratory motion correction (B2B-RMC) were obtained in the proximal right coronary artery of 21 healthy subjects (age, 22-62 years) with no known cardiovascular disease. Lumen and outer wall (lumen + vessel wall) areas were measured in one central slice from each subject and average wall thickness and wall area/outer wall area ratio (W/OW) calculated. Imaging was successful in 18 (86%) subjects with average respiratory efficiency 99.3 ± 1.7%. Coronary vessel wall thickness and W/OW significantly correlate with subject age, increasing by 0.088 mm and 0.031 per decade respectively (R = 0.53, P = 0.024 and R = 0.48, P = 0.046). No relationship was found between lumen area and vessel wall thickness (P = NS), but outer wall area increased significantly with vessel wall thickness at 19 mm(2) per mm (P = 0.046). This is consistent with outward vessel wall remodeling. Despite the small size of our healthy cohort, using high-resolution MR imaging and B2B-RMC, we have demonstrated increasing coronary vessel wall thickness and W/OW with age. The results obtained are consistent with outward vessel wall remodeling. Copyright © 2011 Wiley-Liss, Inc.

  18. Thinner regions of intracranial aneurysm wall correlate with regions of higher wall shear stress: a 7.0 tesla MRI

    Science.gov (United States)

    Blankena, Roos; Kleinloog, Rachel; Verweij, Bon H.; van Ooij, Pim; ten Haken, Bennie; Luijten, Peter R.; Rinkel, Gabriel J.E.; Zwanenburg, Jaco J.M.

    2016-01-01

    Purpose To develop a method for semi-quantitative wall thickness assessment on in vivo 7.0 tesla (7T) MRI images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. Materials and Methods Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients, who underwent 7T MRI with a TSE based vessel wall sequence (0.8 mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to signal of nearby brain tissue and were used as measure for apparent wall thickness (AWT). Spatial wall thickness variation was determined as the interquartile range in AWT (the middle 50% of the AWT range). Wall shear stress was determined using phase contrast MRI (0.5 mm isotropic resolution). We performed visual and statistical comparisons (Pearson’s correlation) to study the relation between wall thickness and wall shear stress. Results 3D colored AWT maps of the aneurysms showed spatial AWT variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of one voxel (0.8mm)). In all aneurysms, AWT was inversely related to WSS (mean correlation coefficient −0.35, P<0.05). Conclusions A method was developed to measure the wall thickness semi-quantitatively, using 7T MRI. An inverse correlation between wall shear stress and AWT was determined. In future studies, this non-invasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and –rupture. PMID:26892986

  19. Shear buckling of cylindrical vessels benchmark exercise

    International Nuclear Information System (INIS)

    Dostal, M; Austin, N.; Combescure, A.; Peano, A.; Angeloni, P.

    1987-01-01

    In Liquid Metal Fast Breeder Reactors (LMFBR) potential shear buckling failures of the primary vessel, induced through seismic excitations, have to be considered. The problem is particularly severe in pool type reactors due to their large size, radius of approximately 10 m, coupled with small wall thicknesses of 50 mm and less. The object of this paper is to provide a comparison of three different computer codes capable of performing buckling analyses and to demonstrate on practical problems the level of accuracy that may be expected in design analyses. Three computer codes were examined ABAQUS, CASTEM (INCA/BILBO) and NOVNL and the computer results were compared directly with experimental data and other commonly used empirical formula. The joint effort was co-ordinated through the CEC Working Group on Codes and Standards AG2. (orig./GL)

  20. Rupture of major vessels after radiation

    International Nuclear Information System (INIS)

    Fajardo, L.F.; Lee, A.

    1975-01-01

    Rupture of irradiated large vessels is an uncommon complication which tends to occur in carotid, aorta, and femoral arteries, in decreasing order of incidence. It particularly affects men subjected to surgery and radiotherapy for epidermoid carcinomas in oropharynx, esophagus, or genitalia. Contrary to some opinion, radiation is not the most significant cause; this spontaneous arterial rupture can occur without radiation. The perforation is not associated with tumor invasion of arterial wall, as has been claimed. Surgical complications, especially necrosis of skin flaps, infection, and fistulas are most important etiologically. Only 2 of the 11 instances that we describe appear to have been caused mainly by radiation. The perforation is usually fatal, but several patients, including 3 of our series (2 carotid, 1 femoral), have been saved by hospital personnel aware of this complication. To prevent it, prolonged exposure or infection of arteries, whether irradiated or not, should be avoided. (auth)

  1. On the Adequacy of API 521 Relief-Valve Sizing Method for Gas-Filled Pressure Vessels Exposed to Fire

    Directory of Open Access Journals (Sweden)

    Anders Andreasen

    2018-03-01

    Full Text Available In this paper, the adequacy of the legacy API 521 guidance on pressure relief valve (PRV sizing for gas-filled vessels subjected to external fire is investigated. Multiple studies show that in many cases, the installation of a PRV offers little or no protection—therefore provides an unfounded sense of security. Often the vessel wall will be weakened by high temperatures, before the PRV relieving pressure is reached. In this article, a multiparameter study has been performed taking into consideration various vessel sizes, design pressures (implicitly vessel wall thickness, vessel operating pressure, fire type (pool fire or jet fire by applying the methodology presented in the Scandpower guideline. A transient thermomechanical response analysis has been carried out to accurately determine vessel rupture times. It is demonstrated that only vessels with relatively thick walls, as a result of high design pressures, benefit from the presence of a PRV, while for most cases no appreciable increase in the vessel survival time beyond the onset of relief is observed. For most of the cases studied, vessel rupture will occur before the relieving pressure of the PRV is reached.

  2. Wall conditioning and particle control in Extrap T2

    Science.gov (United States)

    Bergsåker, H.; Larsson, D.; Brunsell, P.; Möller, A.; Tramontin, L.

    1997-02-01

    The Extrap T2 reversed field pinch experiment is operated with the former OHTE vacuum vessel, of dimensions R = 1.24 m and a = 0.18 m and with a complete graphite liner. It is shown that a rudimentary density control can be achieved by means of frequent helium glow discharge conditioning of the wall. The standard He-GDC is well characterized and reproducible. The trapping and release of hydrogen and impurities at the wall surfaces have been studied by mass spectrometry and surface analysis. The shot to shot particle exchange between wall and plasma can be approximately accounted for.

  3. Analysis, design, and constrution of a sacrificial shield wall

    International Nuclear Information System (INIS)

    Fialkow; Shah, S.B.

    1978-01-01

    The sacrificial shield wall, a cylindrical enclosure around the reactor pressure vessel (RPV), is a major component of nuclear power plants of the Boiling Water Reactor (BWR) type. A method developed for the analysis and design of such walls is described which eliminates shortcomings in methods used in current practice. The method treats the wall as a space frame of ring beams and columns and includes the skin plates as finite elements. Design loadings, load combinations, and acceptance criteria are presented. Results by this method are furnished and compared with results by an alternate method. Significant design features are described and a narrative of construction procedures is included. (Author)

  4. Finite difference program for calculating hydride bed wall temperature profiles

    International Nuclear Information System (INIS)

    Klein, J.E.

    1992-01-01

    A QuickBASIC finite difference program was written for calculating one dimensional temperature profiles in up to two media with flat, cylindrical, or spherical geometries. The development of the program was motivated by the need to calculate maximum temperature differences across the walls of the Tritium metal hydrides beds for thermal fatigue analysis. The purpose of this report is to document the equations and the computer program used to calculate transient wall temperatures in stainless steel hydride vessels. The development of the computer code was motivated by the need to calculate maximum temperature differences across the walls of the hydrides beds in the Tritium Facility for thermal fatigue analysis

  5. Particle Trajectories in Rotating Wall Cell Culture Devices

    Science.gov (United States)

    Ramachandran N.; Downey, J. P.

    1999-01-01

    Cell cultures are extremely important to the medical community since such cultures provide an opportunity to perform research on human tissue without the concerns inherent in experiments on individual humans. Development of cells in cultures has been found to be greatly influenced by the conditions of the culture. Much work has focused on the effect of the motions of cells in the culture relative to the solution. Recently rotating wall vessels have been used with success in achieving improved cellular cultures. Speculation and limited research have focused on the low shear environment and the ability of rotating vessels to keep cells suspended in solution rather than floating or sedimenting as the primary reasons for the improved cellular cultures using these devices. It is widely believed that the cultures obtained using a rotating wall vessel simulates to some degree the effect of mi