  1. Heat flux to the helium cryogenic system elements in the case of incidental vacuum vessel ventilation with atmospheric air

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The selection process for size in safety equipment for cold vessels or process pipes in cryogenic systems should take into consideration the incidental ventilation of the vacuum vessel with atmospheric air. In this case, a significant heat input toward the cold elements of the system can be expected. A number of experimental investigations have been done for the elements at liquid helium temperature which have been covered with 10 layers of MLI. The typical values of the heat flux were measured in a range of 3.7 to 5.0 kW/m2 of the element surface. The helium temperature parts are typically surrounded by thermal shields that are kept in a temperature range of 50-80K. On the external side, the thermal shields are covered with 30-40 layers of MLI while on the internal side, the shields are bare. The theoretical calculations of heat flux to the thermal shield, with respect to the possibility of air condensation and freezing on the bare side of the thermal shield, show that the heat flux to the thermal shield can...

  2. RESULTS OF EXPERIMENT TO DETERMINE CORROSION RATES FOR 304L IN HB-LINE DISSOLVER VESSEL VENTILATION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Mickalonis, J; Kathryn Counts, K

    2008-02-22

    Radioactive material being processed as part of the DE3013 program for HB-Line will result in the presence of chlorides, and in some cases fluorides, in the dissolver. Material Science and Technology developed an experimental plan to evaluate the impact of chloride on corrosion of the dissolver vessel ventilation system. The plan set test variables from the proposed operating parameters, previous test results, and a desired maximum chloride concentration for processing. The test variables included concentrations of nitric acid, fluorides and chlorides, and the presence of a welded and stressed metal coupon. Table 1 contains expected general corrosion rates in the HB-Line vessel vent system from dissolution of 3013 contents of varying nitric acid and chloride content. These general corrosion rates were measured upstream of the condenser in the experiment's offgas system near the entrance to the dissolver. However, they could apply elsewhere in the offgas system, depending on factors not simulated in the testing, including offgas system temperatures and airflow. Localized corrosion was significant in Tests One, Two, and Three. This corrosion is significant because it will probably be the first mode of penetration of the 304L steel in several places in the system. See Table 2. For Tests One and Three, the penetration rate of localized corrosion was much higher than that for general corrosion. It was approximately four times higher in Test One and at least 45 times higher in Test Three, penetrating an entire coupon thickness of 54 mils in 186 hours or less. There was no significant difference in corrosion between welded areas and un-welded areas on coupons. There was also no significant attack on stressed portions of coupons. It is probable that the lack of corrosion was because the stressed areas were facing downwards and offered no place for condensation or deposits to form. Had deposits formed, pitting may have occurred and led to stress corrosion cracking. The

  3. Containment vessel drain system

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  4. [Comparative studies of the circulatory system during high frequency inspiratory ventilation and inspiratory positive pressure ventilation].

    Science.gov (United States)

    Nestorowicz, A; Powała-Niedźwiecki, K

    1989-02-06

    The studies were carried out in 14 dogs in which two different ventilation techniques were used under the general anaesthesia: HFIV and IPPV. Functioning of the cardio-vascular system was evaluated, basing on the measurements of pulse rate, pressure in the peripheral vessels, pulmonary artery and central venous pressure and calculation of the stroke volume, cardiac index, and pulmonary vessels resistance index. It was found that both techniques of ventilation did not exert any effect on the functioning of cardio-vascular system. Stroke volume was lower during IPPV than that during HFIV ventilation.

  5. Ventilation and Heat Recovering System

    Directory of Open Access Journals (Sweden)

    Olga Bancea

    2007-01-01

    Full Text Available Some aspects concerning the heat reducing for ventilation, achieved by using heat recovering components and a combined heating--ventilating system, assuring both comfort and human health are presented. The floor imbedded systems together with air outlets elements could fulfill all the aesthetically desires, as well as comfort and they are ideal for family houses.

  6. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Walker, Iain S.

    2011-04-01

    Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

  7. 46 CFR 32.55-1 - Ventilation of tank vessels constructed on or after July 1, 1951-TB/ALL.

    Science.gov (United States)

    2010-10-01

    ... natural ventilation, with at least one duct extending to immediately below the floor plates will be... 46 Shipping 1 2010-10-01 2010-10-01 false Ventilation of tank vessels constructed on or after July... VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Ventilation and Venting § 32.55-1 Ventilation...

  8. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  9. Preoperational test report, vent building ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Vent Building Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides Heating, Ventilation, and Air Conditioning (HVAC) for the W-030 Ventilation Building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  10. Ventilation systems for high halls

    Energy Technology Data Exchange (ETDEWEB)

    Sodec, F.; Veldboer, W.

    1982-02-01

    A ventilation system for high halls is described which meets the demands of steady air flow in spite of inverse thermal currents, intensive ventilation of working areas during heating and cooling and ventilation free of draught. The main element of the ventilation system is the air outlet in the ceiling, with variable beam direction. The horizontal, rotated beams are superimposed by a vertical beam whose strength may be varied. This way, the beam direction can be adapted to the thermal load of the hall and the height of blowout. The blowout angle is large for heating and small for cooling. Studies have shown that halls are ventilated thoroughly and free of draught by this system. The variable, rotary outlet presented in the article is best suited for heights of 4.00 to 12.00 m. The outlet, with a rated diameter of 400 mm, has been in use for two years now in fields as varied as diecasting works, halls at fairs, sports halls, etc. The air volume flow rate is 1000 to 3000 m/sup 3//h per outlet. A bigger version is now being developed; it will have a rated diameter of 710 mm and an air volume flow rate of 3000 to 9000 m/sup 3//h.

  11. 14 CFR 252.9 - Ventilation systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Ventilation systems. 252.9 Section 252.9... REGULATIONS SMOKING ABOARD AIRCRAFT § 252.9 Ventilation systems. Air carriers shall prohibit smoking whenever the ventilation system is not fully functioning. Fully functioning for this purpose means operating so...

  12. Preoperational test report, primary ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  13. 46 CFR 32.55-5 - Ventilation of tank vessels constructed between November 10, 1936, and July 1, 1951-TB/ALL.

    Science.gov (United States)

    2010-10-01

    ... actuated gas ejectors or blowers or ventilators fitted with heads for natural ventilation, will be approved... 46 Shipping 1 2010-10-01 2010-10-01 false Ventilation of tank vessels constructed between November... HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Ventilation and Venting...

  14. Preoperational test report, primary ventilation condensate system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-01-29

    Preoperational test report for Primary Ventilation Condensate System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides a collection point for condensate generated by the W-030 primary vent offgas cooling system serving tanks AYIOI, AY102, AZIOI, AZI02. The system is located inside a shielded ventilation equipment cell and consists of a condensate seal pot, sampling features, a drain line to existing Catch Tank 241-AZ-151, and a cell sump jet pump. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  15. Hybrid ventilation systems and high performance buildings

    Energy Technology Data Exchange (ETDEWEB)

    Utzinger, D.M. [Wisconsin Univ., Milwaukee, WI (United States). School of Architecture and Urban Planning

    2009-07-01

    This paper described hybrid ventilation design strategies and their impact on 3 high performance buildings located in southern Wisconsin. The Hybrid ventilation systems combined occupant controlled natural ventilation with mechanical ventilation systems. Natural ventilation was shown to provide adequate ventilation when appropriately designed. Proper control integration of natural ventilation into hybrid systems was shown to reduce energy consumption in high performance buildings. This paper also described the lessons learned from the 3 buildings. The author served as energy consultant on all three projects and had the responsibility of designing and integrating the natural ventilation systems into the HVAC control strategy. A post occupancy evaluation of building energy performance has provided learning material for architecture students. The 3 buildings included the Schlitz Audubon Nature Center completed in 2003; the Urban Ecology Center completed in 2004; and the Aldo Leopold Legacy Center completed in 2007. This paper included the size, measured energy utilization intensity and percentage of energy supplied by renewable solar power and bio-fuels on site for each building. 6 refs., 2 tabs., 6 figs.

  16. Modelling and Simulation of Volume Controlled Mechanical Ventilation System

    Directory of Open Access Journals (Sweden)

    Yan Shi

    2014-01-01

    Full Text Available Volume controlled mechanical ventilation system is a typical time-delay system, which is applied to ventilate patients who cannot breathe adequately on their own. To illustrate the influences of key parameters of the ventilator on the dynamics of the ventilated respiratory system, this paper firstly derived a new mathematical model of the ventilation system; secondly, simulation and experimental results are compared to verify the mathematical model; lastly, the influences of key parameters of ventilator on the dynamics of the ventilated respiratory system are carried out. This study can be helpful in the VCV ventilation treatment and respiratory diagnostics.

  17. Evaluating Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Arena, Lois [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2013-02-01

    In an effort to improve housing options near Las Vegas, Nevada, the Clark County Community Resources Division (CCCRD) performs substantial renovations to foreclosed homes. After dramatic energy, aesthetic, and health and safety improvements are made, homes are rented or sold to qualified residents. This report describes the evaluation and selection of ventilation systems for these homes, including key considerations when selecting an ideal system. The report then describes CCCRD’s decision process with respect to ventilation.

  18. 46 CFR 154.1200 - Mechanical ventilation system: General.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Mechanical ventilation system: General. 154.1200 Section... Equipment Cargo Area: Mechanical Ventilation System § 154.1200 Mechanical ventilation system: General. (a... cargo handling equipment must have a fixed, exhaust-type mechanical ventilation system. (b) The...

  19. 46 CFR 154.1205 - Mechanical ventilation system: Standards.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Mechanical ventilation system: Standards. 154.1205... Equipment Cargo Area: Mechanical Ventilation System § 154.1205 Mechanical ventilation system: Standards. (a) Each exhaust type mechanical ventilation system required under § 154.1200 (a) must have ducts for...

  20. Intelligent decision support systems for mechanical ventilation.

    Science.gov (United States)

    Tehrani, Fleur T; Roum, James H

    2008-11-01

    An overview of different methodologies used in various intelligent decision support systems (IDSSs) for mechanical ventilation is provided. The applications of the techniques are compared in view of today's intensive care unit (ICU) requirements. Information available in the literature is utilized to provide a methodological review of different systems. Comparisons are made of different systems developed for specific ventilation modes as well as those intended for use in wider applications. The inputs and the optimized parameters of different systems are discussed and rule-based systems are compared to model-based techniques. The knowledge-based systems used for closed-loop control of weaning from mechanical ventilation are also described. Finally, in view of increasing trend towards automation of mechanical ventilation, the potential utility of intelligent advisory systems for this purpose is discussed. IDSSs for mechanical ventilation can be quite helpful to clinicians in today's ICU settings. To be useful, such systems should be designed to be effective, safe, and easy to use at patient's bedside. In particular, these systems must be capable of noise removal, artifact detection and effective validation of data. Systems that can also be adapted for closed-loop control/weaning of patients at the discretion of the clinician, may have a higher potential for use in the future.

  1. 33 CFR 183.620 - Natural ventilation system.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Natural ventilation system. 183... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Ventilation § 183.620 Natural ventilation system. (a) Except for compartments open to the atmosphere, a natural ventilation system that meets the...

  2. Preoperational test report, recirculation ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-11

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  3. Multiple factors influencing OR ventilation system effectiveness

    Directory of Open Access Journals (Sweden)

    Buhl Sebastian

    2016-09-01

    Full Text Available The issue of surgical site infections has become more critical during the last years. The number of airborne microbes depends on the number released by the staff in the room or supplied from neighbouring rooms. In order to minimize the risk of nosocomial infections during surgical procedures technical developments like ventilation systems were introduced in the operating room (OR. In this study several factors like clothing and types of ventilation systems have been investigated and their impact on the effectiveness for reducing microbial burden in the OR has been assessed. In case of OR-gowns we found a benefit for a disposable Swedish clothing concept regarding microbiological contamination in comparison with the German standard multiuse clothing. Moreover our study shows that there is comparable effectiveness of a fairly novel temperature controlled airflow ventilation system (TAF compared to standard low turbulent uni-directional airflow (TAV.

  4. Advanced design of local ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Kulmala, I. [VTT Manufacturing Technology, Espoo (Finland). Safety Technology

    1997-12-31

    Local ventilation is widely used in industry for controlling airborne contaminants. However, the present design practices of local ventilation systems are mainly based on empirical equations and do not take quantitatively into account the various factors affecting the performance of these systems. The aim of this study was to determine the applicability and limitations of more advanced fluid mechanical methods to the design and development of local ventilation systems. The most important factors affecting the performance of local ventilation systems were determined and their effect was studied in a systematic manner. The numerical calculations were made with the FLUENT computer code and they were verified by laboratory experiments, previous measurements or analytical solutions. The results proved that the numerical calculations can provide a realistic simulation of exhaust openings, effects of ambient air flows and wake regions. The experiences with the low-velocity local supply air showed that these systems can also be modelled fairly well. The results were used to improve the efficiency and thermal comfort of a local ventilation unit and to increase the effective control range of exhaust hoods. In the simulation of the interaction of a hot buoyant source and local exhaust, the predicted capture efficiencies were clearly higher than those observed experimentally. The deviations between measurements and non-isothermal flow calculations may have partly been caused by the inability to achieve grid independent solutions. CFD simulations is an advanced and flexible tool for designing and developing local ventilation. The simulations can provide insight into the time-averaged flow field which may assist us in understanding the observed phenomena and to explain experimental results. However, for successful calculations the applicability and limitations of the models must be known. (orig.) 78 refs.

  5. Vessel Permit System Data Set

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — GARFO issues federal fishing permits annually to owners of fishing vessels who fish in the Greater Atlantic region, as required by federal regulation. These permits...

  6. Energy diagnosis of industrial ventilation systems; Diagnostic energetique des installations de ventilation industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-11-01

    Industrial ventilation systems are numerous and represent an important source of potential energy saving. This book shades light on the principles of ventilation systems used in companies and on the investigation methods to be implemented for an energy diagnosis of these systems. It proposes some solutions for the improvement of existing ventilation systems and some suggestions for the formulation and presentation of recommendations. (J.S.)

  7. Dimensionless study on dynamics of pressure controlled mechanical ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Yan; Niu, Jinglong; Cai, Maolin; Xu, Weiqing [Beihang University, Beijing (Korea, Republic of)

    2015-02-15

    Dynamics of mechanical ventilation system can be referred in pulmonary diagnostics and treatments. In this paper, to conveniently grasp the essential characteristics of mechanical ventilation system, a dimensionless model of mechanical ventilation system is presented. For the validation of the mathematical model, a prototype mechanical ventilation system of a lung simulator is proposed. Through the simulation and experimental studies on the dimensionless dynamics of the mechanical ventilation system, firstly, the mathematical model is proved to be authentic and reliable. Secondly, the dimensionless dynamics of the mechanical ventilation system are obtained. Last, the influences of key parameters on the dimensionless dynamics of the mechanical ventilation system are illustrated. The study provides a novel method to study the dynamic of mechanical ventilation system, which can be referred in the respiratory diagnostics and treatment.

  8. Design guidelines for natural ventilation systems in tertiary sector buildings

    OpenAIRE

    Van Moeseke, Geoffrey; Bruyère, Isabelle; De Herde, André; CISBAT 2005: Renewables in a changing climate

    2005-01-01

    Parameters determining efficiency of natural ventilation systems are numerous. The most important are architecture and system design. This article get onto both but focuses on system design. Through dynamic simulations it shows that natural ventilation management has a large impact on energy saving but most of all on thermal comfort. Natural ventilation techniques are also weighted against hybrid solutions and high efficiency mechanical cooling solutions. Natural ventilation techniques show t...

  9. Modeling and Control of Livestock Ventilation Systems and Indoor Environments

    DEFF Research Database (Denmark)

    Wu, Zhuang; Heiselberg, Per; Stoustrup, Jakob

    2005-01-01

    The hybrid ventilation systems have been widely used for livestock barns to provide optimum indoor climate by controlling the ventilation rate and air flow distribution within the ventilated building structure. The purpose of this paper is to develop models for livestock ventilation systems and i...... constraints and random disturbances is designed through system linearization. The well designed control systems are able to determine the demand ventilation rate and airflow pattern, improve and optimize the indoor Thermal Comfort (TC), Indoor Air Quality (IAQ) and energy use....

  10. Design study: fishing vessel technical information system

    National Research Council Canada - National Science Library

    Park, C.H

    1979-01-01

    ... out. This study is primarily concerned with the design of a Fishing Vessel Technical Information System that will meet the requirements of the Department, and the determination of a schedule and means of data collection and management.

  11. Ion transport membrane module and vessel system

    Energy Technology Data Exchange (ETDEWEB)

    Stein, VanEric Edward [Allentown, PA; Carolan, Michael Francis [Allentown, PA; Chen, Christopher M [Allentown, PA; Armstrong, Phillip Andrew [Orefield, PA; Wahle, Harold W [North Canton, OH; Ohrn, Theodore R [Alliance, OH; Kneidel, Kurt E [Alliance, OH; Rackers, Keith Gerard [Louisville, OH; Blake, James Erik [Uniontown, OH; Nataraj, Shankar [Allentown, PA; van Doorn, Rene Hendrik Elias (Obersulm-Willsbach, DE); Wilson, Merrill Anderson [West Jordan, UT

    2008-02-26

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel.The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  12. Ion transport membrane module and vessel system

    Energy Technology Data Exchange (ETDEWEB)

    Stein, VanEric Edward; Carolan, Michael Francis; Chen, Christopher M.; Armstrong, Phillip Andrew; Wahle, Harold W.; Ohrn, Theodore R.; Kneidel, Kurt E.; Rackers, Keith Gerard; Blake, James Erik; Nataraj, Shankar; van Doorn, Rene Hendrik Elias; Wilson, Merrill Anderson

    2007-02-20

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel. The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  13. Ion transport membrane module and vessel system

    Energy Technology Data Exchange (ETDEWEB)

    Stein, VanEric Edward [Allentown, PA; Carolan, Michael Francis [Allentown, PA; Chen, Christopher M [Allentown, PA; Armstrong, Phillip Andrew [Orefield, PA; Wahle, Harold W [North Canton, OH; Ohrn, Theodore R [Alliance, OH; Kneidel, Kurt E [Alliance, OH; Rackers, Keith Gerard [Louisville, OH; Blake, James Erik [Uniontown, OH; Nataraj, Shankar [Allentown, PA; Van Doorn, Rene Hendrik Elias (Obersulm-Willsbach, DE); Wilson, Merrill Anderson [West Jordan, UT

    2012-02-14

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel. The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  14. Advanced Controls for Residential Whole-House Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    Whole-house ventilation systems are becoming commonplace in new construction, remodeling/renovation, and weatherization projects, driven by combinations of specific requirements for indoor air quality (IAQ), health and compliance with standards, such as ASHRAE 62.2. Ventilation systems incur an energy penalty on the home via fan power used to drive the airflow, and the additional space-conditioning load associated with heating or cooling the ventilation air. Finding a balance between IAQ and energy use is important if homes are to be adequately ventilated while not increasing the energy burden. This study used computer simulations to examine RIVEC the Residential Integrated Ventilation Controller - a prototype ventilation controller that aims to deliver whole-house ventilation rates that comply with ventilation standards, for the minimum use of energy. Four different whole-house ventilation systems were simulated, both with and without RIVEC, so that the energy and IAQ results could be compared. Simulations were conducted for 13 US climate zones, three house designs, and three envelope leakage values. The results showed that the RIVEC controller could typically return ventilation energy savings greater than 40percent without compromising long-term chronic or short-term acute exposures to relevant indoor contaminants. Critical and average peak power loads were also reduced as a consequence of using RIVEC.

  15. Calculation of Industrial Enterprise Ventilation System by Network Integral Method

    Directory of Open Access Journals (Sweden)

    Mihienkova Evgeniya I.

    2016-01-01

    Full Text Available This paper describe a ventilation system calculation of the technology building industrial enterprise. On the basis of the calculation model for the enterprise offered technical decision of ventilation systems, subject to a compliance exchange multiplicity, purification efficiency, decontamination from the work area; provided the required volume of gas extraction from process equipment according to the sanitary standards and environmental requirements. Produced selection of ventilation equipment parameters, solved the problem of the air exchange balancing between ventilation systems to prevent the emergence of parasitic flows between the rooms building. SigmaNet software package was used for the implement the calculation.

  16. 46 CFR 72.15-20 - Ventilation for crew quarters and passenger spaces.

    Science.gov (United States)

    2010-10-01

    ... shown that a natural system will provide adequate ventilation. However, vessels which trade regularly in... 46 Shipping 3 2010-10-01 2010-10-01 false Ventilation for crew quarters and passenger spaces. 72... VESSELS CONSTRUCTION AND ARRANGEMENT Ventilation § 72.15-20 Ventilation for crew quarters and passenger...

  17. 46 CFR 92.15-15 - Ventilation for crew quarters and, where provided, passenger spaces.

    Science.gov (United States)

    2010-10-01

    ..., unless it can be shown that a natural system will provide adequate ventilation. However, vessels which... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation for crew quarters and, where provided...) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT Ventilation § 92.15-15 Ventilation for crew...

  18. Vessel Electronic Reporting System (VERS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The VERS system is composed of a database and other related applications which facilitate the reporting of electronically collected research data via Fisheries...

  19. [Large vessels vasculopathy in systemic sclerosis].

    Science.gov (United States)

    Tejera Segura, Beatriz; Ferraz-Amaro, Iván

    2015-12-07

    Vasculopathy in systemic sclerosis is a severe, in many cases irreversible, manifestation that can lead to amputation. While the classical clinical manifestations of the disease have to do with the involvement of microcirculation, proximal vessels of upper and lower limbs can also be affected. This involvement of large vessels may be related to systemic sclerosis, vasculitis or atherosclerotic, and the differential diagnosis is not easy. To conduct a proper and early diagnosis, it is essential to start prompt appropriate treatment. In this review, we examine the involvement of large vessels in scleroderma, an understudied manifestation with important prognostic and therapeutic implications. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  20. Ventilation Systems Operating Experience Review for Fusion Applications

    Energy Technology Data Exchange (ETDEWEB)

    L. C. Cadwallader

    1999-12-01

    This report is a collection and review of system operation and failure experiences for air ventilation systems in nuclear facilities. These experiences are applicable for magnetic and inertial fusion facilities since air ventilation systems are support systems that can be considered generic to nuclear facilities. The report contains descriptions of ventilation system components, operating experiences with these systems, component failure rates, and component repair times. Since ventilation systems have a role in mitigating accident releases in nuclear facilities, these data are useful in safety analysis and risk assessment of public safety. An effort has also been given to identifying any safety issues with personnel operating or maintaining ventilation systems. Finally, the recommended failure data were compared to an independent data set to determine the accuracy of individual values. This comparison is useful for the International Energy Agency task on fusion component failure rate data collection.

  1. A RESEARCH ON VENTILATION EFFICIENCY OF PIPED VENTILATION SYSTEMS IN GEOTHERMALLY HEATED GREENHOUSES

    Directory of Open Access Journals (Sweden)

    İbrahim Örüng

    2016-07-01

    Full Text Available Greenhouse play significant roles in human nutrition. Vegetable and fruit consumption at certain amounts is the basic pre-condition for a well nutrition. It is possible to produce sufficient quantities of fruits and vegetables in places with available climate conditions. However, fruits and vegetables should be grown in special buildings to have a year-long production in places without available climate conditions. These places include under-cover production facilities, greenhouses, low and high tunnel facilities. Environmental conditions are adjusted are adjusted in greenhouses as to provide proper conditions for plant growth and development. Ventilation is used to remove excess heat, moisture and carbon dioxide from the greenhouses. Either natural or mechanical ventilation is used in greenhouses. Mechanical ventilation systems have various advantages over natural systems. However, mostly natural ventilation systems are preferred because of their low installation and operational costs. Both systems operates based on negative pressure. Air exchange rates are usually low in winters and it is quite hard to evenly distribute cold fresh air within the greenhouse. Air inlets are usually placed over side walls and outlets are commonly placed along the ridge. In this study an alternative natural ventilation system was proposed for more efficient ventilation of the greenhouses. In this system, fresh air gets into the greenhouse through ventilation pipes installed beneath the greenhouse floor. The incoming fresh air also heated with geothermal hot water lines, thus direct contact of cold fresh air is prevented. The design and efficiency of piped ventilation systems were provided in this paper.

  2. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  3. Fire protection countermeasures for containment ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Alvares, N.; Beason, D.; Bergman, V.; Creighton, J.; Ford, H.; Lipska, A.

    1980-08-25

    The goal of this project is to find countermeasures to protect High Efficiency Particulate Air (HEPA) filters, in exit ventilation ducts, from the heat and smoke generated by fire. Initially, methods were developed to cool fire-heated air by fine water spray upstream of the filters. It was recognized that smoke aerosol exposure to HEPA filters could also cause disruption of the containment system. Through testing and analysis, several methods to partially mitigate the smoke exposure to the HEPA filters were identified. A continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. The technique is capable of protecting HEPA filters over the total time duration of the test fires. The reason for success involved the modification of the prefiltration media. Commercially available filter media has particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, rolling filter media were laminated with the desired properties. The approach was Edisonian, but truncation in short order to a combination of prefilters was effective. The application of this technique was qualified, since it is of use only to protect HEPA filters from fire-generated smoke aerosols. It is not believed that this technique is cost effective in the total spectrum of containment systems, especially if standard fire protection systems are available in the space. But in areas of high-fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified.

  4. 46 CFR 169.315 - Ventilation (other than machinery spaces).

    Science.gov (United States)

    2010-10-01

    ... section is satisfied, a vessel having only a natural ventilation system must satisfy the following: V/A≥1... 46 Shipping 7 2010-10-01 2010-10-01 false Ventilation (other than machinery spaces). 169.315... SCHOOL VESSELS Construction and Arrangement Hull Structure § 169.315 Ventilation (other than machinery...

  5. Uncertainties in different level assessments of domestic ventilation systems

    NARCIS (Netherlands)

    Bokel, R.M.J.; Yang, Z.; Cauberg, J.J.M.

    2013-01-01

    In order to improve the quality of ventilation systems, assessments are widely used. In this paper, 3 main assessment levels are distinguished based on the number of ventilation systems to be assessed and the assessment objective. The main assessment levels distinguished in this paper are global

  6. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Somerville, MA (United States); Bergey, Daniel [Building Science Corporation, Somerville, MA (United States)

    2014-02-01

    In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  7. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bergey, Daniel [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  8. YMP Engineered Barrier Systems Scaled Ventilation Testing

    Energy Technology Data Exchange (ETDEWEB)

    S.D. Dunn; B. Lowry; B. Walsh; J.D. Mar; C. Howard; R. Johnston; T. Williams

    2002-11-22

    Yucca Mountain, approximately 100 miles northwest of Las Vegas, Nevada, has been selected as the site for the nation's first geologic repository for high level nuclear waste. The Yucca Mountain Project (YMP) is currently developing the design for the underground facilities. Ventilation is a key component of the design as a way to maintain the desired thermal conditions in the emplacement drifts prior to closure. As a means of determining the effects of continuous ventilation on heat removal from the emplacement drifts two series of scaled ventilation tests have been performed. Both test series were performed in the DOE/North Las Vegas Atlas facility. The tests provided scaled (nominally 25% of the full scale emplacement drift design) thermal and flow process data that will be used to validate YMP heat and mass transport codes. The Phase I Ventilation Test series evaluated the ability of ambient ventilation air to remove energy under varying flow and input power conditions. The Phase II Ventilation Test series evaluated the ability of pre-conditioned ventilation air to remove energy under varying flow, input temperature and moisture content, and simulated waste package input power conditions. Twenty-two distinct ventilation tests were run.

  9. 46 CFR 177.600 - Ventilation of enclosed and partially enclosed spaces.

    Science.gov (United States)

    2010-10-01

    ... ventilation system unless natural ventilation in all ordinary weather conditions is satisfactory to the OCMI... 46 Shipping 7 2010-10-01 2010-10-01 false Ventilation of enclosed and partially enclosed spaces... PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Ventilation § 177.600 Ventilation of...

  10. On analysis of operating efficiency of autonomous ventilation systems

    Directory of Open Access Journals (Sweden)

    Kostuganov Arman

    2017-01-01

    Full Text Available The paper deals with the causes and consequences of malfunctioning of natural and mechanical ventilation systems in civil buildings of Russia. Furthermore it gives their classification and analysis based on the literature review. On the basis of the analysis technical solutions for improving the efficiency of ventilation systems in civil buildings are summarized and the field of their application is specified. Among the offered technical solutions the use of autonomous ventilation systems with heat recovery is highlighted as one of the most promising and understudied. Besides it has a wide range of applications. The paper reviews and analyzes the main Russian and foreign designs of ventilation systems with heat recovery that are mostly used in practice. Three types of such systems: UVRK-50, Prana-150, ТеFо are chosen for consideration. The sequence of field tests of selected autonomous ventilation systems have been carried out in order to determine the actual air exchange and efficiency of heat recovery. The paper presents the processed results of the research on the basis of which advantages and disadvantages of the tested ventilation systems are identified and recommendations for engineering and manufacturing of new design models of autonomous ventilation systems with heat recovery are formulated.

  11. Nuclear reactor pressure vessel support system

    Science.gov (United States)

    Sepelak, George R.

    1978-01-01

    A support system for nuclear reactor pressure vessels which can withstand all possible combinations of stresses caused by a postulated core disrupting accident during reactor operation. The nuclear reactor pressure vessel is provided with a flange around the upper periphery thereof, and the flange includes an annular vertical extension formed integral therewith. A support ring is positioned atop of the support ledge and the flange vertical extension, and is bolted to both members. The plug riser is secured to the flange vertical extension and to the top of a radially outwardly extension of the rotatable plug. This system eliminates one joint through which fluids contained in the vessel could escape by making the fluid flow path through the joint between the flange and the support ring follow the same path through which fluid could escape through the plug risers. In this manner, the sealing means to prohibit the escape of contained fluids through the plug risers can also prohibit the escape of contained fluid through the securing joint.

  12. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2014-02-01

    This report, developed by Building America research team CARB, addresses adding or improving mechanical ventilation systems to existing homes. The goal of this report is to assist decision makers and contractors in making informed decisions when selecting ventilation systems for homes. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including examination of relevant codes and standards. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors.

  13. Characterization of natural ventilation in wastewater collection systems.

    Science.gov (United States)

    Ward, Matthew; Corsi, Richard; Morton, Robert; Knapp, Tom; Apgar, Dirk; Quigley, Chris; Easter, Chris; Witherspoon, Jay; Pramanik, Amit; Parker, Wayne

    2011-03-01

    The purpose of the study was to characterize natural ventilation in full-scale gravity collection system components while measuring other parameters related to ventilation. Experiments were completed at four different locations in the wastewater collection systems of Los Angeles County Sanitation Districts, Los Angeles, California, and the King County Wastewater Treatment District, Seattle, Washington. The subject components were concrete gravity pipes ranging in diameter from 0.8 to 2.4 m (33 to 96 in.). Air velocity was measured in each pipe using a carbon-monoxide pulse tracer method. Air velocity was measured entering or exiting the components at vents using a standpipe and hotwire anemometer arrangement. Ambient wind speed, temperature, and relative humidity; headspace temperature and relative humidity; and wastewater flow and temperature were measured. The field experiments resulted in a large database of measured ventilation and related parameters characterizing ventilation in full-scale gravity sewers. Measured ventilation rates ranged from 23 to 840 L/s. The experimental data was used to evaluate existing ventilation models. Three models that were based upon empirical extrapolation, computational fluid dynamics, and thermodynamics, respectively, were evaluated based on predictive accuracy compared to the measured data. Strengths and weaknesses in each model were found and these observations were used to propose a concept for an improved ventilation model.

  14. 46 CFR 190.15-15 - Ventilation for living spaces and quarters.

    Science.gov (United States)

    2010-10-01

    ... mechanical system unless it can be shown that a natural system will provide adequate ventilation. By a... 46 Shipping 7 2010-10-01 2010-10-01 false Ventilation for living spaces and quarters. 190.15-15... VESSELS CONSTRUCTION AND ARRANGEMENT Ventilation § 190.15-15 Ventilation for living spaces and quarters...

  15. Preoperational test report, primary ventilation condenser cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-10-29

    This represents the preoperational test report for the Primary Ventilation Condenser Cooling System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system uses a closed chilled water piping loop to provide offgas effluent cooling for tanks AY101, AY102, AZ1O1, AZ102; the offgas is cooled from a nominal 100 F to 40 F. Resulting condensation removes tritiated vapor from the exhaust stack stream. The piping system includes a package outdoor air-cooled water chiller with parallel redundant circulating pumps; the condenser coil is located inside a shielded ventilation equipment cell. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  16. Optimized damper control of pressure and airflow in ventilation systems

    DEFF Research Database (Denmark)

    Koulani, Chrysanthi Sofia; Hviid, Christian Anker; Terkildsen, Søren

    2014-01-01

    Conventional control strategies in variable air volume (VAV) ventilation systems do not take fully into advantage the potential energy savings since the system operation is based on maintaining a constant static pressure (CSP) set point in the main duct irrespective of the actual pressure demand...... by using the Simulink programming tool which is addon software to MATLAB mathematical programming language. A model of a VAV ventilation system was created in Simulink based on the International Building Physics Toolbox (IBPT); the IBPT thermal zone was remodelled in order to calculate dynamically...... the airflow demand according to the zone air temperature. The performance of the Simulink model was evaluated based on the experimental setup of the ventilation system. The SPR control method established stable system operation and was proven efficient to maintain comfortable space conditions while reducing...

  17. Mixing Ventilation System in a Single-Aisle Aircraft Cabin

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Zhang, Chen; Wojcik, Kamil

    2014-01-01

    Traditionally, air is supplied to the aircraft cabin either by individual nozzles or by supply slots. The air is expected to be fully mixed in the cabin, and the system is considered to be a mixing ventilation system. This paper will provide measurements on the mixing flow in an aircraft cabin...... and present a design procedure of the system. Finally, a personalised ventilation system will be described, which can be used together with the mixing ventilation system. The experiments are made in a full-scale, left side mock-up of a single-aisle (Boeing 737) cabin with four seats. The four passengers...... are simulated by thermal manikins. Velocity, temperature and cross-infection risk are measured. The experiments proved that fully developed turbulent flow will take place in the cabin and that the flow element theory can be used for the design procedure when the air flow rate is above a certain level...

  18. Design of energy efficient ventilation and air-conditioning systems

    CERN Document Server

    Seppänen, Olli; Bertilsson, Thore; Maripuu, Mari-Liis; Lamy, Hervé; Vanden Borre, Alex

    2012-01-01

    This guidebook covers numerous system components of ventilation and air-conditioning systems and shows how they can be improved by applying the latest technology products. Special attention is paid to details, which are often overlooked in the daily design practice, resulting in poor performance of high quality products once they are installed in the building system.

  19. Implementation and assessment of a novel mechanical ventilatory system following a noisy ventilation regime

    OpenAIRE

    Marcus Henrique Victor Júnior

    2014-01-01

    This study concerns the development of a novel mechanical ventilation system, with a view to analysing the results of a new mechanical ventilation technique, referred to noisy ventilation. Additionally, the study addresses the assessment of the system, involving the estimation of certain mechanical parameters of the respiratory system under noisy ventilation and discusses a pilot trial in vivo, with a pig. During acute respiratory failure, intubation and invasive mechanical ventilation may be...

  20. Water spray ventilator system for continuous mining machines

    Science.gov (United States)

    Page, Steven J.; Mal, Thomas

    1995-01-01

    The invention relates to a water spray ventilator system mounted on a continuous mining machine to streamline airflow and provide effective face ventilation of both respirable dust and methane in underground coal mines. This system has two side spray nozzles mounted one on each side of the mining machine and six spray nozzles disposed on a manifold mounted to the underside of the machine boom. The six spray nozzles are angularly and laterally oriented on the manifold so as to provide non-overlapping spray patterns along the length of the cutter drum.

  1. A decision support system to determine optimal ventilator settings.

    Science.gov (United States)

    Akbulut, Fatma Patlar; Akkur, Erkan; Akan, Aydin; Yarman, B Siddik

    2014-01-10

    Choosing the correct ventilator settings for the treatment of patients with respiratory tract disease is quite an important issue. Since the task of specifying the parameters of ventilation equipment is entirely carried out by a physician, physician's knowledge and experience in the selection of these settings has a direct effect on the accuracy of his/her decisions. Nowadays, decision support systems have been used for these kinds of operations to eliminate errors. Our goal is to minimize errors in ventilation therapy and prevent deaths caused by incorrect configuration of ventilation devices. The proposed system is designed to assist less experienced physicians working in the facilities without having lung mechanics like cottage hospitals. This article describes a decision support system proposing the ventilator settings required to be applied in the treatment according to the patients' physiological information. The proposed model has been designed to minimize the possibility of making a mistake and to encourage more efficient use of time in support of the decision making process while the physicians make critical decisions about the patient. Artificial Neural Network (ANN) is implemented in order to calculate frequency, tidal volume, FiO2 outputs, and this classification model has been used for estimation of pressure support / volume support outputs. For the obtainment of the highest performance in both models, different configurations have been tried. Various tests have been realized for training methods, and a number of hidden layers mostly affect factors regarding the performance of ANNs. The physiological information of 158 respiratory patients over the age of 60 and were treated in three different hospitals between the years 2010 and 2012 has been used in the training and testing of the system. The diagnosed disease, core body temperature, pulse, arterial systolic pressure, diastolic blood pressure, PEEP, PSO2, pH, pCO2, bicarbonate data as well as the

  2. Validation of the performance of a practical blood vessel imaging system to facilitate vessel punctures

    Science.gov (United States)

    Cuper, Natascha J.; Verdaasdonk, Rudolf M.; de Roode, Rowland

    2009-02-01

    A practical system to visualize vessels underneath the skin has been developed, based on near-infrared (NIR) transillumination. A study in the clinical setting proved the system to be useful as a support in blood withdrawal in young children. During clinical application it was found that performance varied depending on vessel size, depth of vessels and surrounding lighting conditions. To gain more insight on the different variables that determine functioning of the system, we performed phantom studies. A combined liquid/solid phantom was fabricated with similar optical properties as the tissue layers of skin reported in literature at 850 nm. This phantom was used to estimate the depth of visibility in the relation to vessel size and darkness of the skin. Vessel contrast was determined analytically from images and evaluated by 3 independent observers. The knowledge gained from these experiments will be helpful to improve the imaging system and develop a solid phantom to be used as a gold standard to test the system under various clinical lighting conditions. The working range of the system was found to be appropriate to visualize the vessels used for the most procedures, such as blood withdrawal and placement of intravenous lines.

  3. Radioactive waste tank ventilation system incorporating tritium control

    Energy Technology Data Exchange (ETDEWEB)

    Rice, P.D. [ICF Kaiser Hanford Company, Richland, WA (United States)

    1997-08-01

    This paper describes the development of a ventilation system for radioactive waste tanks at the U.S. Department of Energy`s (DOE) Hanford Site in Richland, Washington. The unique design of the system is aimed at cost-effective control of tritiated water vapor. The system includes recirculation ventilation and cooling for each tank in the facility and a central exhaust air clean-up train that includes a low-temperature vapor condenser and high-efficiency mist eliminator (HEME). A one-seventh scale pilot plant was built and tested to verify predicted performance of the low-temperature tritium removal system. Tests were conducted to determine the effectiveness of the removal of condensable vapor and soluble and insoluble aerosols and to estimate the operating life of the mist eliminator. Definitive design of the ventilation system relied heavily on the test data. The unique design features of the ventilation system will result in far less release of tritium to the atmosphere than from conventional high-volume dilution systems and will greatly reduce operating costs. NESHAPs and TAPs NOC applications have been approved, and field construction is nearly complete. Start-up is scheduled for late 1996. 3 refs., 4 figs., 2 tabs.

  4. Effective, industrial ventilation systems. New generation of ventilation systems under development; Effectieve, industriele ventilatiesystemen

    Energy Technology Data Exchange (ETDEWEB)

    Moons, A.; Knoll, B. [TNO Bouw en Ondergrond, Delft (Netherlands)

    2008-02-15

    Industrial processes and tools can expose employees to various harmful substances. This is a burden that often takes place decentralized. Room ventilation alone usually does not offer enough protection. New ventilation concepts can offer employees effective protection. (mk) [Dutch] Industriele processen en gereedschappen kunnen werknemers blootstellen aan allerlei schadelijke stoffen. Een belasting die vaak zeer decentraal plaatsheeft. Alleen ruimteventilatie biedt doorgaans onvoldoende bescherming. Nieuwe ventilatieconcepten kunnen medewerkers wel een effectieve bescherming bieden.

  5. Experimental Study of Air Distribution and Ventilation Effectiveness in a Room with a Combination of Different Mechanical Ventilation and Heating/Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Simone, Angela; Krajcik, Michal

    2011-01-01

    Mixing and displacement ventilation are common systems in commercial buildings, while mixing ventilation is used in residential buildings. Displacement ventilation provides fresh air to the occupied zone in a more efficient way than mixing ventilation but it is important to know how well it works...

  6. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  7. Availability Analysis of the Ventilation Stack CAM Interlock System

    CERN Document Server

    Young, J

    2000-01-01

    Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies, and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability.

  8. Heating, Ventilation and Air-Conditioning Systems, Part of Indoor Air Quality Design Tools for Schools

    Science.gov (United States)

    The main purposes of a Heating, Ventilation, and Air-Conditioning system are to help maintain good indoor air quality through adequate ventilation with filtration and provide thermal comfort. HVAC systems are among the largest energy consumers in schools.

  9. Possible scenarios for a safety upgrade of the ventilation system

    CERN Document Server

    Inigo-Golfin, J

    2009-01-01

    This paper/presentation describes the existing LHC ventilation (HVAC) system, the design principle followed for the LEP Project and the modifications implemented for the LHC Project. A discussion on possible referential standards to compare the existing system with is presented and possible axes for its improvement, based on these referentials, are discussed. Finally, some recommendations are given based on the system's present capabilities and the estimated investment necessary to achieve compliance to the referentials chosen.

  10. Development of an integrated data acquision system for research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Mehra, P.; Desai, R.G.P.

    This article describes an integrated data acquisition system (IDAS) designed and developed for multi-oceanographic research vessels. The prime motivation was to provide a flexible system, which could be used in the context of ocean related...

  11. Vessel Monitoring Systems Study. Volume I - Technical Analysis.

    Science.gov (United States)

    1980-09-01

    In the Port and Tanker Safety Act of 1978 the U.S. Conress directed the Department of Transportation to performa a study on the desirability and feasibility of a shore-station system for monitoring vessels (including fishing vessels)offshore within t...

  12. Pressure Dynamic Characteristics of Pressure Controlled Ventilation System of a Lung Simulator

    OpenAIRE

    Yan Shi; Shuai Ren; Maolin Cai; Weiqing Xu; Qiyou Deng

    2014-01-01

    Mechanical ventilation is an important life support treatment of critically ill patients, and air pressure dynamics of human lung affect ventilation treatment effects. In this paper, in order to obtain the influences of seven key parameters of mechanical ventilation system on the pressure dynamics of human lung, firstly, mechanical ventilation system was considered as a pure pneumatic system, and then its mathematical model was set up. Furthermore, to verify the mathematical model, a prototyp...

  13. VWPS: A Ventilator Weaning Prediction System with Artificial Intelligence

    Science.gov (United States)

    Chen, Austin H.; Chen, Guan-Ting

    How to wean patients efficiently off mechanical ventilation continues to be a challenge for medical professionals. In this paper we have described a novel approach to the study of a ventilator weaning prediction system (VWPS). Firstly, we have developed and written three Artificial Neural Network (ANN) algorithms to predict a weaning successful rate based on the clinical data. Secondly, we have implemented two user-friendly weaning success rate prediction systems; the VWPS system and the BWAP system. Both systems could be used to help doctors objectively and effectively predict whether weaning is appropriate for patients based on the patients' clinical data. Our system utilizes the powerful processing abilities of MatLab. Thirdly, we have calculated the performance through measures such as sensitivity and accuracy for these three algorithms. The results show a very high sensitivity (around 80%) and accuracy (around 70%). To our knowledge, this is the first design approach of its kind to be used in the study of ventilator weaning success rate prediction.

  14. Exposure of ventilation system cleaning workers to harmful microbiological agents.

    Science.gov (United States)

    Gołofit-Szymczak, Małgorzata; Ławniczek-Wałczyk, Anna; Górny, Rafał L

    2013-01-01

    Regular inspection of the cleanliness of the ventilation systems, as well as their periodic cleaning and disinfection, if necessary, are the main factors of the proper maintenance of each system. Performing maintenance operations on the ventilation system, workers are exposed to risk associated with the exposure to harmful biological agents. The aim of this study was to assess the employees' exposure to bioaerosols during maintenance work on ventilation systems. Bioaerosol measurements were carried out using a button sampler. The microbial particles were collected on gelatin filters. Settled-dust samples from the inner surface of the air ducts and filter-mat samples were selected for the microbiological analysis. In the collected air, dust and filter samples the concentration of bacteria and fungi were determined. Bacteria and fungi concentrations ranged between 3.6 x 10(2)-2.2 x 10(4) CFU/m3 and 4.7 x 10(2)-4.5 x 10(3) CFU/m3 at workplaces where the operations connected with mechanical ventilation cleaning were performed and 2.2 x 10(4)-1.2 x 10(5) CFU/m2 and 9.8 x 10(1)-2.5 x 10(2) CFU/m3 at workplaces where filter exchange was performed, respectively. The qualitative analysis of microorganisms isolated from the air in all studied workplaces revealed that the most prevalent bacteria belonged to Bacillus genus. The average concentrations of bacteria and fungi in filter-mat samples were 3.3 x 10(3) CFU/cm2 and 1.4 x 10(4) CFU/cm2, respectively. In settled-dust samples, average concentrations were 591 CFU/100 cm2 and 52 CFU/100 cm2, for bacteria and fungi respectively. Workers cleaning ventilation systems are exposed to harmful biological agents classified into risk groups, 1 and 2, according to their level of the risk of infection. The research conducted in the workplace can be the basis of risk assessment related to exposure to harmful biological agents during maintenance work in ventilation.

  15. Exposure of ventilation system cleaning workers to harmful microbiological agents

    Directory of Open Access Journals (Sweden)

    Małgorzata Gołofit-Szymczak

    2013-10-01

    Full Text Available Background: Regular inspection of the cleanliness of the ventilation systems, as well as their periodic cleaning and disinfection, if necessary, are the main factors of the proper maintenance of each system. Performing maintenance operations on the ventilation system, workers are exposed to risk associated with the exposure to harmful biological agents. The aim of this study was to assess the employees' exposure to bioaerosols during maintenance work on ventilation systems. Material and Methods: Bioaerosol measurements were carried out using a button sampler. The microbial particles were collected on gelatin filters. Settled-dust samples from the inner surface of the air ducts and filter-mat samples were selected for the microbiological analysis. In the collected air, dust and filter samples the concentration of bacteria and fungi were determined. Results: Bacteria and fungi concentrations ranged between 3.6×102-2.2×104 CFU/m3 and 4.7×102-4.5×103 CFU/m3 at workplaces where the operations connected with mechanical ventilation cleaning were performed and 2.2×104-1.2×105 CFU/m3 and 9.8×101-2.5×102 CFU/m3 at workplaces where filter exchange was performed, respectively. The qualitative analysis of microorganisms isolated from the air in all studied workplaces revealed that the most prevalent bacteria belonged to Bacillus genus. The average concentrations of bacteria and fungi in filter-mat samples were 3.3×103 CFU/cm2 and 1.4×104 CFU/cm2, respectively. In settled-dust samples, average concentrations were 591 CFU/100 cm2 and 52 CFU/100 cm2, for bacteria and fungi respectively. Conclusions: Workers cleaning ventilation systems are exposed to harmful biological agents classified into risk groups, 1 and 2, according to their level of the risk of infection. The research conducted in the workplace can be the basis of risk assessment related to exposure to harmful biological agents during maintenance work in ventilation. Med Pr 2013;64(5:613–623

  16. Airflow Sensitivity Assessment Based on Underground Mine Ventilation Systems Modeling

    Directory of Open Access Journals (Sweden)

    Wacław Dziurzyński

    2017-09-01

    Full Text Available This paper presents a method for determining the sensitivity of the main air flow directions in ventilation subnetworks to changes in aerodynamic resistance and air density in mine workings. The authors have developed formulae for determining the sensitivity of the main subnetwork air flows by establishing the degree of dependency of the air volume stream in a given working on the variations in resistance or air density of other workings of the network. They have been implemented in the Ventgraph mine ventilation network simulator. This software, widely used in Polish collieries, provides an extended possibility to predict the process of ventilation, air distribution and, in the case of underground fire, the spread of combustion gasses. The new method facilitates an assessment by mine ventilation services of the stability of ventilation systems in exploitation areas and determines the sensitivity of the main subnetwork air flow directions to changes in aerodynamic resistance and air density. Recently in some Polish collieries new longwalls are developed in seams located deeper than the bottom of the intake shaft. Such a solution is called “exploitation below the level of access” or “sublevel”. The new approach may be applied to such developments to assess the potential of changes in direction and air flow rates. In addition, an interpretation of the developed sensitivity indicator is presented. While analyzing air distributions for sublevel exploitation, the application of current numerical models for calculations of the distribution results in tangible benefits, such as the evaluation of the safety or risk levels for such exploitation. Application of the Ventgraph computer program, and particularly the module POŻAR (fire with the newly developed options, allows for an additional approach to the sensitivity indicator in evaluating air flow safety levels for the risks present during exploitation below the level of the intake shaft. The

  17. Method to assess the performance of ventilation systems in dwellings considering the influence of uncertainties

    NARCIS (Netherlands)

    Yang, Z.; Cauberg, J.J.M.; Tenpierik, M.J.

    2011-01-01

    Normally, the design of a ventilation system in a dwelling is based on national regulations, related design rules, building tradition and general knowledge about healthy indoor air quality, ventilation and air handling units. In practice, the actual performance of ventilation systems is determined

  18. Confinement Vessel Assay System: Design and Implementation Report

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine C. [Los Alamos National Laboratory; Bourne, Mark M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Evans, Louise [Los Alamos National Laboratory; Mayo, Douglas R. [Los Alamos National Laboratory; Gomez, Cipriano D. [Retired CMR-OPS: OPERATIONS; Miko, David K. [Los Alamos National Laboratory; Salazar, William R. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory

    2012-07-18

    Los Alamos National Laboratory has a number of spherical confinement vessels remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1- to 2-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. We have developed a neutron assay system for the purposes of Materials Control and Accountability (MC&A) measurements of the vessel prior to and after cleanout. We present our approach to confronting the challenges in designing, building, and testing such a system. The system was designed to meet a set of functional and operational requirements. A Monte Carlo model was developed to aid in optimizing the detector design as well as to predict the systematic uncertainty associated with confinement vessel measurements. Initial testing was performed to optimize and determine various measurement parameters, and then the system was characterized using {sup 252}Cf placed a various locations throughout the measurement system. Measurements were also performed with a {sup 252}Cf source placed inside of small steel and HDPE shells to study the effect of moderation. These measurements compare favorably with their MCNPX model equivalent, making us confident that we can rely on the Monte Carlo simulation to predict the systematic uncertainty due to variations in response to material that may be localized at different points within a vessel.

  19. Evaluating Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R.; Arena, L.

    2013-02-01

    During the course of this project, an affordable and high performance ductwork system to directly address the problems of thermal losses, poor efficiency, and air leakage was designed. To save space and enable direct connections between different floors of the building, the ductwork system was designed in such a way that it occupied interior or exterior frame wall cavities. The ductwork system satisfied building regulations for structural support when bridging multiple floors, the spread of fire and smoke, and insulation to reduce the heat flow into or out of the building. Retrofits of urban residential buildings will be the main focus for the application of this ductwork system. Highly reflective foils and insulating materials were used to aid in the increase of the overall R-value of the ductwork itself and the wall assembly. It is expected that the proposed system will increase the efficiency of the HVAC system and the thermal resistance of the building envelope. The performance of the proposed ductwork design was numerically evaluated in a number of different ways. Our results indicate that the duct method is a very cost attractive alternative to the conventional method.

  20. Numerical simulation of volume-controlled mechanical ventilated respiratory system with 2 different lungs.

    Science.gov (United States)

    Shi, Yan; Zhang, Bolun; Cai, Maolin; Zhang, Xiaohua Douglas

    2017-09-01

    Mechanical ventilation is a key therapy for patients who cannot breathe adequately by themselves, and dynamics of mechanical ventilation system is of great significance for life support of patients. Recently, models of mechanical ventilated respiratory system with 1 lung are used to simulate the respiratory system of patients. However, humans have 2 lungs. When the respiratory characteristics of 2 lungs are different, a single-lung model cannot reflect real respiratory system. In this paper, to illustrate dynamic characteristics of mechanical ventilated respiratory system with 2 different lungs, we propose a mathematical model of mechanical ventilated respiratory system with 2 different lungs and conduct experiments to verify the model. Furthermore, we study the dynamics of mechanical ventilated respiratory system with 2 different lungs. This research study can be used for improving the efficiency and safety of volume-controlled mechanical ventilation system. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Histological evaluation and optimization of surgical vessel sealing systems

    Science.gov (United States)

    Lathrop, Robert; Ryan, Thomas; Gaspredes, Jonathan; Woloszko, Jean; Coad, James E.

    2017-02-01

    Surgical vessel sealing systems are widely used to achieve hemostasis and dissection in open surgery and minimally invasive, laparoscopic surgery. This enabling technology was developed about 17 years ago and continues to evolve with new devices and systems achieving improved outcomes. Histopathological assessment of thermally sealed tissues is a valuable tool for refining and comparing performance among surgical vessel sealing systems. Early work in this field typically assessed seal time, burst rate, and failure rate (in-situ). Later work compared histological staining methods with birefringence to assess the extent of thermal damage to tissues adjacent to the device. Understanding the microscopic architecture of a sealed vessel is crucial to optimizing the performance of power delivery algorithms and device design parameters. Manufacturers rely on these techniques to develop new products. A system for histopathological evaluation of vessels and sealing performance was established, to enable the direct assessment of a treatment's tissue effects. The parameters included the commonly used seal time, pressure burst rate and failure rate, as well as extensions of the assessment to include its likelihood to form steam vacuoles, adjacent thermal effect near the device, and extent of thermally affected tissue extruded back into the vessel lumen. This comprehensive assessment method provides an improved means of assessing the quality of a sealed vessel and understanding the exact mechanisms which create an optimally sealed vessel.

  2. Exergy analysis of ventilation systems with energy recovery

    OpenAIRE

    I.O. Sukhodub; V.I. Deshko

    2014-01-01

    Thermal, mechanical and chemical components of room air exergy and its change depending on the outside air parameters (temperature, humidity and pressure) have been examined for different periods of the year, using the climatic data for Kiev (IWEC). In winter the thermal component dominates, whereas in summer the chemical one prevails. Various approaches to exergy efficiency definition of ventilation systems with energy recovery (namely, a universal, functional and maximum exergy efficien...

  3. Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, G.C.; Corsi, R.L.; Destaillats, H.; Nazaroff, W.W.; Wells, J.R.

    2006-05-01

    Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.

  4. Expert system for determining welding condition for a pressure vessel

    National Research Council Canada - National Science Library

    Fukuda, Shuichi; Morita, Hideki; Yamauchi, Yoshihisa; Nagasawa, Isao; Tsuji, Shuichi

    1990-01-01

    This paper describes the outline of the expert system for producing a Welding Procedure Specification for a pressure vessel which was developed with the grant from the Ministry of International Trade...

  5. Systems Theoretic Process Analysis Applied to an Offshore Supply Vessel Dynamic Positioning System

    Science.gov (United States)

    2016-06-01

    support vessels, cable layers, pipe-laying vessels, shuttle tankers , trenching and dredging vessels, [and] supply vessels” [3]. The term DP system ... SYSTEMS THEORETIC PROCESS ANALYSIS APPLIED TO AN OFFSHORE SUPPLY VESSEL DYNAMIC POSITIONING SYSTEM by Blake Ryan Abrecht B.S. Systems ...Engineering with a Focus on Human Factors United States Air Force Academy, 2014 SUBMITTED TO THE INSTITUTE FOR DATA, SYSTEMS , AND SOCIETY IN PARTIAL

  6. 77 FR 18689 - Changes to Standard Numbering System, Vessel Identification System, and Boating Accident Report...

    Science.gov (United States)

    2012-03-28

    ..., Vessel Identification System, and Boating Accident Report Database AGENCY: Coast Guard, DHS. ACTION... Standard Numbering System (SNS), the Vessel Identification System, and accident reporting; require... Vessel Identification System II. Regulatory History On May 7, 2010, we published a notice of proposed...

  7. Testing and Evaluation of the Bear Medical Systems, Inc. Bear 33 Volume Ventilator System

    Science.gov (United States)

    1990-12-01

    the ventilator and humidifier were attached to a Michigan Instruments Model 1600 mechanical lung analyzer, which simulated the patient’s lungs. We...AD-A241 836 USAFSAM-TR-90-22 TESTING AND EVALUATION OF THE BEAR MEDICAL SYSTEMS, INC. BEAR 33 VOLUME VENTILATOR SYSTEM Teresa R. Lewis, Captain, USAF...Medical Systems, Inc. PE - 62202F Bear 33 Volume Ventilator System PR - 7930 6. AUTHOR(S) TA - 16 WU - 12 Teresa R. Lewis, and Thomas E. Philbeck, Jr. 7

  8. Controlled ventilation with the Mapleson D system A theoretical and experimental study.

    Science.gov (United States)

    Seeley, H F; Barnes, P K; Conway, C M

    1977-02-01

    A theoretical analysis has been performed to show the interrelationships between alveolar carbon dioxide concentration, carbon dioxide output, alveolar ventilation and fresh gas flow during controlled ventilation with the Mapleson D system. The model and forms of equation used have been substantiated by experiments in which dogs were ventilated through a coaxial version of the Mapleson D system at varying levels of fresh gas flow and alveolar ventilation. By assuming that man ventilated with this system behaves as does the dog, a nomogram has been produced to predict alveolar carbon dioxide concentrations at any levels of fresh gas flow and minute volume.

  9. Comparison of physical performances of the ventilation systems in low-energy residential houses

    Energy Technology Data Exchange (ETDEWEB)

    Maier, T. [Buero V. Maier, Hoechstadt, Erlangen (Germany); Krzaczek, M.; Tejchman, J. [Gdansk University of Technology, Faculty of Civil and Environmental Engineering, 80-952 Gdansk-Wrzeszcz, Narutowicza 11/12 (Poland)

    2009-03-15

    The paper presents experimental results of the effect of ventilation systems in modern residential low-energy houses on thermal and humid conditions, heat consumption and perception of thermal comfort and air quality by their residents. Practical projects of modern residential houses with various ventilation systems which realize thermal, humid and psycho-physical comfort were worked out. To analyze the influence of ventilation systems on human comfort, results of questionnaires and comprehensive experimental measurements were taken into account. For measurements, 22 identical residential houses in Germany were chosen where 4 various ventilation systems were installed: gravitational (natural) ventilation, air heating system, mechanical ventilation with in- and out-leading air elements and a function of heat recovery and mechanical ventilation with single ventilators. The following parameters were measured in test units: relative air humidity, concentration of CO{sub 2} in the air, air temperature, consumption of electricity, gas and heat, working time of the window opening, working time of the mechanical ventilation and number of residents. Advantages and disadvantages of ventilation systems were outlined. Experimental results were evaluated. Relationships between ventilation systems and thermal comfort were discussed by taking into account opinions of house residents. (author)

  10. Ventilation System Type and the Resulting Classroom Temperature and Air Quality During Heating Season

    DEFF Research Database (Denmark)

    Gao, Jie; Wargocki, Pawel; Wang, Yi

    2014-01-01

    The present study investigated how different ventilation system types influence classroom temperature and air quality. Five classrooms were selected in the same school. They were ventilated by manually operable windows, manually operable windows with exhaust fan, automatically operable windows...... with and without exhaust fan and by mechanical ventilation system. Temperature, relative humidity, carbon dioxide (CO2) concentration and opening of windows were continuously monitored for one month during heating season in 2012. Classroom with manually operable windows had the highest carbon dioxide concentration...... levels so that the estimated ventilation rate was the lowest compared with the classrooms ventilated with other systems. Temperatures were slightly lower in classroom ventilated by manually operable windows with exhaust fan. Windows were opened seldom even in the classroom ventilated by manually operable...

  11. Technology Solutions Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    A. Rudd and D. Bergey

    2015-08-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.

  12. Firefighter's compressed air breathing system pressure vessel development program

    Science.gov (United States)

    Beck, E. J.

    1974-01-01

    The research to design, fabricate, test, and deliver a pressure vessel for the main component in an improved high-performance firefighter's breathing system is reported. The principal physical and performance characteristics of the vessel which were required are: (1) maximum weight of 9.0 lb; (2) maximum operating pressure of 4500 psig (charge pressure of 4000 psig); (3) minimum contained volume of 280 in. 3; (4) proof pressure of 6750 psig; (5) minimum burst pressure of 9000 psig following operational and service life; and (6) a minimum service life of 15 years. The vessel developed to fulfill the requirements described was completely sucessful, i.e., every category of performence was satisfied. The average weight of the vessel was found to be about 8.3 lb, well below the 9.0 lb specification requirement.

  13. Pressure Dynamic Characteristics of Pressure Controlled Ventilation System of a Lung Simulator

    Directory of Open Access Journals (Sweden)

    Yan Shi

    2014-01-01

    Full Text Available Mechanical ventilation is an important life support treatment of critically ill patients, and air pressure dynamics of human lung affect ventilation treatment effects. In this paper, in order to obtain the influences of seven key parameters of mechanical ventilation system on the pressure dynamics of human lung, firstly, mechanical ventilation system was considered as a pure pneumatic system, and then its mathematical model was set up. Furthermore, to verify the mathematical model, a prototype mechanical ventilation system of a lung simulator was proposed for experimental study. Last, simulation and experimental studies on the air flow dynamic of the mechanical ventilation system were done, and then the pressure dynamic characteristics of the mechanical system were obtained. The study can be referred to in the pulmonary diagnostics, treatment, and design of various medical devices or diagnostic systems.

  14. Building America Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts, Tyler, Texas

    Energy Technology Data Exchange (ETDEWEB)

    2015-08-01

    ?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.

  15. [Sanitary and epidemiological evaluation of the ventilation and air-conditioning systems of public buildings].

    Science.gov (United States)

    Dvorianov, V V

    2012-01-01

    The microbial contamination of ventilation and air conditioning systems was examined in the administrative buildings. The author proposes a set of indicators, methods for determining the scope of investigations, as well as sampling tactics and criteria for evaluating the microbial contamination of the ventilation and air-conditioning systems. The content of yeasts and molds in the delivered air has been found to be of importance for evaluating the sanitary-and epidemiological state of ventilation systems.

  16. Ventilation systems for multi-unit residential buildings : performance requirements and alternative approaches

    Energy Technology Data Exchange (ETDEWEB)

    Hill, D.

    2003-09-01

    A growing proportion of housing in Canada consists of multi-unit residential buildings (MURBs). Ventilation strategies have not changed much over the past three decades. Research conducted by Canada Mortgage and Housing Corporation (CMHC) and others has shown that conventional ventilation strategies consume significant amounts of energy, are noisy, consume internal floor area, and can become conduits for pests and smoke. As a result, a research project was initiated to develop performance requirements and alternative approaches for ventilation systems in MURBs. The issues to be addressed by alternative ventilation systems were identified through literature review. The various codes and standards applicable to ventilation capacities for apartments in MURBs in Canada were evaluated. It was revealed that the ventilation system airflow rates required for any given apartment and the amount of ventilation that should be provided by infiltration varies greatly depending on the codes or standards selected. The performance parameters that were identified in this paper were: ventilation performance, capital and operating costs, maintenance, fire and smoke control, noise issues, comfort, system issues, and owner and designer construction issues. The following four different alternative ventilation systems were discussed: (1) passive vents with suite-based mechanical exhaust, (2) balanced individual suites with heat recovery (HRV) units, (3) balanced floor-by-floor systems with heat recovery, and (4) balanced central systems with heat recovery. Further testing and assessment is needed before these proposed systems can enter the marketable phase. More research is also needed into the characterization of stack and wind pressures in MURBs. 5 tabs.

  17. Development of automatic reactor vessel inspection systems: development of data acquisition and analysis system for the nuclear vessel weld

    Energy Technology Data Exchange (ETDEWEB)

    Park, C. H.; Lim, H. T.; Um, B. G. [Korea Advanced Institute of Science and Technology, Taejeon (Korea)

    2001-03-01

    The objective of this project is to develop an automated ultrasonic data acquisition and data analysis system to examine the reactor vessel weldsIn order to examine nuclear vessel welds including reactor pressure vessel(RPV), huge amount of ultrasonic data from 6 channels should be able to be on-line processed. In addition, ultrasonic transducer scanning device should be remotely controlled, because working place is high radiation area. This kind of an automated ultrasonic testing equipment has not been developed domestically yet In order to develop an automated ultrasonic testing system, RPV ultrasonic testing equipments developed in foreign countries were investigated and the capability of high speed ultrasonic signal processing hardwares was analyzed in this study, ultrasonic signal processing system was designed. And also, ultrasonic data acquisition and analysis software was developed. 11 refs., 6 figs., 9 tabs. (Author)

  18. Control Strategies to Conserve Energy in All-Air Heating Ventilation and Air Conditioning Systems.

    Science.gov (United States)

    1979-05-14

    York, ASHRAE, Inc. American Society of Heating, Refrigerating and Air- Conditioning Engineers. "Standards for Natural and Mechanical Ventilation ...or REPoRT a P61mO0 COVERED 1 Control Strategies to Conserve Energy in All-Air Heating Ventilation and Air Conditioning THESIS 14Systems o ~~~sGOG...Morrison, William James (M. S., Civil Engineering) Control Strategies to Conserve Energy in All-Air Heating Ventilation and Air Conditioning Systems Report

  19. An overview of the TA-55, Building PF-4 ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-02-22

    An overview of the TA-55, Building PF-4 ventilation system is provided in the following sections. Included are descriptions of the zone configurations, equipment-performance criteria, ventilation support systems, and the ventilation-system evaluation criteria. Section 4.2.1.1 provides a brief discussion of the ventilation system function. Section 4.2.1.2 provides details on the overall system configuration. Details of system interfaces and support systems are provided in Section 4.2.1.3. Section 4.2.1.4 describes instrumentation and control needed to operate the ventilation system. Finally, Sections 4.2.1.5 and 4.2.1.6 describe system surveillance/maintenance and Technical Safety Requirements (TSR) Limitations, respectively. Note that the numerical parameters included in this description are considered nominal; set points and other specifications actually fall within operational bands.

  20. Real-time evaluation of ventilation filter-bank systems.

    Science.gov (United States)

    Moyer, Ernest S; Commodore, Michael A; Hayes, Jeffrey L; Fotta, Steven A; Berardinelli, Stephen P

    2007-01-01

    This study evaluated two government facility ventilation systems. One was a metropolitan government office complex with a recirculation system where outside air was the makeup air; the other was a NIOSH facility that used 100% outside air with no recirculation. The methodology employed was a modified American Society of Agricultural Engineers standard (S525) for testing total enclosure filtration efficiency, in agricultural tractor cabs, with optical particle counters (OPC). The low-efficiency bag filters were tested when new and after being in the ventilation system for 3 months. The replacement medium-efficiency filters were evaluated for 6 months (the manufacturer's suggested change-out schedule). These eight-chamber, medium-efficiency filters had an increased filter surface area that resulted in increased airflow through the system. Unfortunately, these filters contained electrostatic filter media and lost filtration efficiency rapidly, which was subsequently confirmed in a 30-day study conducted to determine an appropriate change-out schedule for the eight-chamber bag filters. The study determined that less than 6 months' use was justified due to the reduced efficiency of the electrostatic filter media. The NIOSH facility's air handler #8 (100% outside air unit) was upgraded from electrostatic bag filters, which had a suggested 9-month change-out schedule, to V Bank mechanical, wet-laid, glass fiber filters. The results of a 3-year evaluation showed that the V Bank filters had better filter efficiency after 3 years of service than the electrostatic filters had at 9 months. Both studies employed matched OPC instruments to reduce instrument-to-instrument bias. The methodology is adaptable to monitoring the total efficiency of most air filtration systems, and results can help make decisions about upgrading filter performance.

  1. Applied patent RFID systems for building reacting HEPA air ventilation system in hospital operation rooms.

    Science.gov (United States)

    Lin, Jesun; Pai, Jar-Yuan; Chen, Chih-Cheng

    2012-12-01

    RFID technology, an automatic identification and data capture technology to provide identification, tracing, security and so on, was widely applied to healthcare industry in these years. Employing HEPA ventilation system in hospital is a way to ensure healthful indoor air quality to protect patients and healthcare workers against hospital-acquired infections. However, the system consumes lots of electricity which cost a lot. This study aims to apply the RFID technology to offer a unique medical staff and patient identification, and reacting HEPA air ventilation system in order to reduce the cost, save energy and prevent the prevalence of hospital-acquired infection. The system, reacting HEPA air ventilation system, contains RFID tags (for medical staffs and patients), sensor, and reacting system which receives the information regarding the number of medical staff and the status of the surgery, and controls the air volume of the HEPA air ventilation system accordingly. A pilot program was carried out in a unit of operation rooms of a medical center with 1,500 beds located in central Taiwan from Jan to Aug 2010. The results found the air ventilation system was able to function much more efficiently with less energy consumed. Furthermore, the indoor air quality could still keep qualified and hospital-acquired infection or other occupational diseases could be prevented.

  2. 78 FR 6732 - Changes to Standard Numbering System, Vessel Identification System, and Boating Accident Report...

    Science.gov (United States)

    2013-01-31

    ... SECURITY Coast Guard 33 CFR Parts 173, 174, 181, and 187 RIN 1625-AB45 Changes to Standard Numbering System, Vessel Identification System, and Boating Accident Report Database AGENCY: Coast Guard, DHS. ACTION: Rule... Numbering System, Vessel Identification System, and Boating Accident Report Database rule became effective...

  3. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Science.gov (United States)

    Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik

    2017-12-01

    The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  4. Computer-simulation study on fire behaviour in the ventilated cavity of ventilated façade systems

    Directory of Open Access Journals (Sweden)

    Giraldo María P.

    2013-11-01

    Full Text Available Fire spread through the façades is widely recognized as one of the fastest pathways of fire spreading in the buildings. Fire may spread through the façade in different ways depending on the type of façade system and on the elements and materials from which it is constructed. Ventilated façades are multilayer systems whose main feature is the creation of an air chamber of circulating air between the original building wall and the external cladding. The “chimney effect” in the air cavity is a mechanism that improves the façade's thermal behaviour and avoids the appearance of moisture from rain or condensation. However, in a event of fire, it may contribute to the quickest spreading of fire, representing a significant risk to the upper floors of a building. This study deals with some aspects of fire propagation through the ventilated cavity in ventilated façade systems. Also we review the provisions stipulated by the Spanish building code (Código Técnico de la Edificación, CTE [1] to avoid fire spread outside the building. The results highlight the importance of the use of proper fire barriers to ensure the compartmentalization of the ventilated cavity, as well as the use of non-combustible thermal insulation materials, among others. In addition, based on the results, it might be considered that the measures stipulated by the CTE are insufficient to limit the risks associated with this kind of façades systems. The study has been performed using field models of computational fluid-dynamics. In particular, the Fire Dynamics Simulator (FDS software has been used to numerically solve the mathematical integration models.

  5. FAST FLUX TEST FACILITY CONCEPTUAL SYSTEM DESIGN DESCRIPTION FOR THE HEATING AND VENTILATION SYSTEM NO. 25

    Energy Technology Data Exchange (ETDEWEB)

    None

    1969-12-05

    The Heating and Ventilation System provides the atmospheric conditions in FFTF as required to assure that plant objectives can be met in a safe and practical manner. Included are functions and design requirements, a physical description of the system, safety considerations, principles of operation, and maintenance principles.

  6. Energy analysis of the personalized ventilation system in hot and humid climates

    DEFF Research Database (Denmark)

    Schiavon, S.; Melikov, Arsen Krikor; Sekhar, C.

    2010-01-01

    Personalized ventilation (PV) is an individually controlled air distribution system aimed at improving the quality of inhaled air and the thermal comfort of each occupant. Numerous studies have shown that PV in comparison with traditional mechanical ventilation systems may improve occupants’ health......, inhaled air quality, thermal comfort, and self-estimated productivity. Little is known about its energy performance. In this study, the energy consumption of a personalized ventilation system introduced in an office building located in a hot and humid climate (Singapore) has been investigated by means...... of simulations with the empirically tested IDA-ICE software. The results reveal that the use of PV may reduce the energy consumption substantially (up to 51%) compared to mixing ventilation when the following control strategies are applied: (a) reducing the airflow rate due to the higher ventilation...

  7. Performance analysis of a new design of office diffuse ceiling ventilation system

    DEFF Research Database (Denmark)

    Fan, Jianhua; Hviid, Christian Anker; Yang, Honglu

    2013-01-01

    This paper aims to document and analyse performance of a new design of diffuse ceiling ventilation system in a typical office room. A full scale measurement is carried out in a climate chamber with an office setup at the Technical University of Denmark. Indoor air temperatures, air speeds, wall...... surface temperatures, pressure loss of the ceiling and ventilation effectiveness are measured for an air change rate of 3.5 h-1 and 5.1 h -1 respectively. A computational fluid dynamics model of the office with the diffuse ceiling ventilation system is built and validated by the full scale measurement....... The measurements of pressure loss across the ceiling show a low pressure drop between the plenum and the occupied zone. Ventilation effectiveness is measured to be close to 1 on average under the tested conditions. It is shown that the diffuse ceiling ventilation system is able to remove indoor pollutant...

  8. Passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2008-01-01

    In building design the requirements for energy consumption for ventilation, heating and cooling and the requirements for increasingly better indoor climate are two opposing factors. This paper presents the schematic layout and simulation results of an innovative multifunc-tional ventilation concept...... with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University...

  9. An Evaluation of a Proposed Ventilation System for Melbourne's CH2 Building

    Directory of Open Access Journals (Sweden)

    Lu Aye

    2012-11-01

    Full Text Available The understanding of ventilation requirements in commercial buildings has been significantly revised in the last 10-15 years. A link between health, productivity and increased fresh air use has been established by some research and this understanding underpins the ventilation philosophy adopted for the CH2 building. The ventilation system design for CH2 that has been evaluated in this paper envisages a mechanically driven system during the day, using the displacement technique to distribute filtered air. All introduced air will be drawn from outside and no recycling of air will occur. Natural ventilation will be employed at night using the stack effect, enhanced by turbine ventilators. This paper critiques the proposed ventilation system in the light of international experience and the particular conditions of the building's location. The evidence suggests that natural ventilation sometimes may be inadequate to achieve the desired objectives. Minimization of indoor pollutants, adequate filtration and high levels of ventilation should, however, ensure satisfactory air quality during occupied hours.

  10. Development of ROV System for FOSAR in Reactor Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Soo; Kim, Tae Won; Lee, Sung Uk; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Nam Kyun [Korea Plant Service and Engineering Co., Seongnam (Korea, Republic of)

    2011-10-15

    Foreign object in the reactor vessel is susceptible to damage the fuel. Prior to reloading fuel assemblies into the core, FOSAR(Foreign Object Search And Retrieval) activities were performed on and beneath the lower core plate with conventional equipment. However, the reactor vessel is limited to humans who are susceptible to radiation exposure, and conventional equipment is hard to access because of the complexity of the structure. To improve the convenience of use and retrieval ability in the under-core plate region, we are developing a FOSAR system carried by ROV (Remotely Operated Vehicle). In this paper, we describe a ROV system developed. The ROV system is composed of robot vehicle and remote control unit. The vehicle has 4 thrusters, tilt, camera, light and depth sensor, etc. Considering radiation damage, processors are not equipped on the vehicle. Control signals and sensing signals are transferred through umbilical cable. Remote control unit is composed of electric driving module and two computers which one is for the control and the other is for the detection of robot position. Control computer has a joystick user input and video/signal input, and transmit motor control signal and lens control signal via CAN/RS485 communication. And the other computers transmit information of vehicle position to the control computer via serial communication. Information of vehicle position is obtained through image processing algorithm. The acquiring camera of vehicle is on the flange of reactor vessel. Simulations on the detection of vehicle position are performed at the reactor vessel mockup which scaled down by 6 and verified to use in the control of robot by visual tracking. And functional test has been performed on the air condition. In the future, performance test will be carried out real sized mockup and underwater condition

  11. Noxious gases in rabbit housing systems: effects of cross and longitudinal ventilation

    Directory of Open Access Journals (Sweden)

    Francesco da Borso

    2016-12-01

    Full Text Available Animal welfare is a matter of increasing interest due to ethical and economical worries regarding animal rights and the sustainability of meat production. Ammonia, carbon dioxide, and methane can be produced in the livestock buildings and, if not adequately controlled by ventilation, can be dangerous for animals and farmers. The aim of the present paper is to study the effects of different ventilation systems in rabbit buildings based on the temporal patterns and the spatial distribution of these noxious gases. The experimental measurements were conducted in two rabbit farms with genetically homogeneous animals subjected to the same diet. Two buildings with different forced ventilation layouts (cross ventilation - building A and longitudinal ventilation - building B were subjected to the monitoring of indoor environmental conditions (temperature, relative humidity, ammonia, carbon dioxide, methane over a whole year. In both the buildings, ventilation was adjusted automatically by means of electronic control units, which were controlled by temperature sensors, located at the centre of the buildings. Gas concentrations inside the buildings followed clearly defined sinusoidal patterns on a daily basis with the highest values reached in winter during the morning hours for ammonia and during the night hours for carbon dioxide and methane. In particular, ammonia revealed a maximum concentration of 30.7 mg m–3 in building A (cross ventilation and 12.9 mg m–3 in building B (longitudinal ventilation, whereas the minimum values were 6.0 and 4.2 mg m–3, in building A and B, respectively. As a consequence, daily mean concentrations of noxious gases, solely could not be considered representative of the actual conditions of air quality in the buildings. The airflow direction clearly influenced the spatial concentration of ammonia, which showed different patterns in the two buildings. In building A, the highest ammonia concentration was in a diffuse

  12. 46 CFR 25.45-1 - Heating and lighting systems on vessels carrying passengers for hire.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Heating and lighting systems on vessels carrying... UNINSPECTED VESSELS REQUIREMENTS Cooking, Heating, and Lighting Systems § 25.45-1 Heating and lighting systems on vessels carrying passengers for hire. (a) No fuel may be used in any heating or lighting system on...

  13. TVENT: a computer program for analysis of tornado-induced transients in ventilation systems. [TVENT

    Energy Technology Data Exchange (ETDEWEB)

    Duerre, K.H.; Andrae, R.W.; Gregory, W.S.

    1978-07-01

    The report describes TVENT, a portable FORTRAN computer program for predicting flows and pressures in a ventilation system subject to a tornado. The pressure and flow values calculated by TVENT can be used as a basis for structural analysis. TVENT is a one-dimensional, lumped-parameter model with incompressible flow augmented by fluid storage. The theoretical basis for the mathematical modeling and analysis is presented, and a description of the input for the computer code is provided. Modeling techniques specific to ventilation systems are described. Sample problems illustrate the use of TVENT in analyzing ventilation systems. Other sample problems illustrate modeling techniques used in reducing complex systems.

  14. A Bayesian decision-support system for diagnosing ventilator-associated pneumonia

    NARCIS (Netherlands)

    Schurink, C.A.; Visscher, S.; Lucas, P.J.; van Leeuwen, H.J.; Buskens, E.; Hoff, R.G.; Hoepelman, A.I.; Bonten, M.J.

    2007-01-01

    OBJECTIVE: To determine the diagnostic performance of a Bayesian Decision-Support System (BDSS) for ventilator-associated pneumonia (VAP). DESIGN: A previously developed BDSS, automatically obtaining patient data from patient information systems, provides likelihood predictions of VAP. In a

  15. Power Efficiency of Systems Applied for Heating Building and Structure External Walls with Ventilated Air Spaces

    OpenAIRE

    I. F. Fialko; A. S. Statsenko

    2009-01-01

    The paper considers power-efficient systems applied for heating building and structure external walls with ventilated air spaces and prescribes directions and problems pertaining to power-efficiency improvement of such systems.

  16. Development of automatic reactor vessel inspection systems; development of data acquisition and analysis system for the nuclear vessel weld

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Po; Park, C. H.; Kim, H. T.; Noh, H. C.; Lee, J. M.; Kim, C. K.; Um, B. G. [Research Institute of KAITEC, Seoul (Korea)

    2002-03-01

    The objective of this project is to develop an automated ultrasonic data acquisition and data analysis system to examine heavy vessel welds. In order to examine nuclear vessel welds including reactor pressure vessel(RPV), huge amount of ultrasonic data from 6 channels should be able to be on-line processed. In addition, ultrasonic transducer scanning device should be remotely controlled, because working place is high radiation area. This kind of an automated ultrasonic testing equipment has not been developed domestically yet. In order to develop an automated ultrasonic testing system, RPV ultrasonic testing equipments developed in foreign countries were investigated and the capability of high speed ultrasonic signal processing hardwares was analyzed. In this study, ultrasonic signal processing system was designed. And also, ultrasonic data acquisition software was developed. The new systems were tested on the RPV welds of Ulchin Unit 6 to confirm their functions and capabilities. They worked very well as designed and the tests were successfully completed. 13 refs., 34 figs., 11 tabs. (Author)

  17. Structural and functional features of central nervous system lymphatic vessels.

    Science.gov (United States)

    Louveau, Antoine; Smirnov, Igor; Keyes, Timothy J; Eccles, Jacob D; Rouhani, Sherin J; Peske, J David; Derecki, Noel C; Castle, David; Mandell, James W; Lee, Kevin S; Harris, Tajie H; Kipnis, Jonathan

    2015-07-16

    One of the characteristics of the central nervous system is the lack of a classical lymphatic drainage system. Although it is now accepted that the central nervous system undergoes constant immune surveillance that takes place within the meningeal compartment, the mechanisms governing the entrance and exit of immune cells from the central nervous system remain poorly understood. In searching for T-cell gateways into and out of the meninges, we discovered functional lymphatic vessels lining the dural sinuses. These structures express all of the molecular hallmarks of lymphatic endothelial cells, are able to carry both fluid and immune cells from the cerebrospinal fluid, and are connected to the deep cervical lymph nodes. The unique location of these vessels may have impeded their discovery to date, thereby contributing to the long-held concept of the absence of lymphatic vasculature in the central nervous system. The discovery of the central nervous system lymphatic system may call for a reassessment of basic assumptions in neuroimmunology and sheds new light on the aetiology of neuroinflammatory and neurodegenerative diseases associated with immune system dysfunction.

  18. Computational study of smoke flow control in garage fires and optimization of the ventilation system

    Directory of Open Access Journals (Sweden)

    Banjac Miloš J.

    2009-01-01

    Full Text Available With the aim of evaluating capabilities of a ventilation system to control the spread of smoke in the emergency operating mode, thereby providing conditions for safe evacuation of people from a fire-struck area, computational fluid dynamics simulation of a fire in a semi-bedded garage was conducted. Using the experimental results of combustion dynamics of a passenger car on fire, optimal positions of ventilation openings were determined. According to recommendations by DIN EN 12101 standard, the operating modes of a ventilation system were verified and optimal start time of the smoke extraction system was defined.

  19. 46 CFR 27.205 - What are the requirements for internal communication systems on towing vessels?

    Science.gov (United States)

    2010-10-01

    ... requirements for internal communication systems on towing vessels? (a) You must ensure that your vessel is fitted with a communication system between the engine room and the operating station that— (1) Consists... electrical system on your towing vessel; and (2) Provides two-way voice communication and calling between the...

  20. Ventilation system type, classroom environmental quality and pupils' perceptions and symptoms

    DEFF Research Database (Denmark)

    Gao, Jie; Wargocki, Pawel; Wang, Yi

    2014-01-01

    The present study investigated indoor climate and window opening behaviour by pupils, as well as their perceptions and symptoms in classrooms with different types of ventilation systems. Four classrooms were selected in the same school in suburban Denmark. Classroom ventilation was achieved either......-heating and heating seasons; CO2 concentration was used to estimate average classroom ventilation rates. At the end of each measuring period, the pupils were asked to report their perceptions of the indoor environment and their acute health-related symptoms. The classroom in which ventilation was achieved by manually...... operable windows had the highest air temperatures and CO2 concentrations during both non-heating and heating season; the estimated average air-change rate was lowest in this classroom. The classroom with mechanical ventilation had the highest estimated average air-change rate. Windows were frequently...

  1. Upgrade of a transverse ventilation system in a bi-directional tunnel

    Directory of Open Access Journals (Sweden)

    Vidmar Peter

    2012-01-01

    Full Text Available The Karavanke tunnel forms an important link between Slovenia and Austria. The almost 8 km long tunnel is operated with bi-directional traffic and does not have dedicated escape routes. Moreover, the ventilation in case of fire does not satisfy requirements of the EU Directive 2004/54/EC that specifies the minimum requirements for tunnels in the trans-European road network. The paper present results of the research conducted regarding the possibility of upgrade the existing system in order to reach the required level of safety at lower costs possible. It is shown that with simple but novel adaptations of the ventilation system, a sizeable increase in the overall level of safety can be achieved. The methodology applied is a combination of a simple pipe model for tunnel ventilation and for detailed fluid dynamics analysis the CFD model is used. The existing ventilation system that in fire ventilation extracts smoke from a single duct is replaced with the smoke extraction from both ducts applying four axial fans. The analysis is focused on air/smoke flow through the vents and ducts and on pressure drops calculated over the length of the ventilation duct and its influence on the total flow. The change of the flow condition also has influence on ventilation fan operation point that is investigated in the paper as well.

  2. Association of ventilation system type with SBS symptoms in office workers

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli; Fisk, William J.

    2001-02-07

    This paper provides a review and synthesis of current knowledge about the associations of ventilation system types in office buildings with sick building syndrome symptoms and discusses potential explanations for the associations. Relative to natural ventilation, air conditioning, with or without humidification, was consistently associated with a statistically significant increase in the prevalence of one or more SBS symptoms. Prevalences were typically higher by approximately 30% to 200% in the air conditioned buildings. In two of three assessments from a single study, symptom prevalences were also significantly higher in air conditioned buildings than in buildings with simple mechanical ventilation and no humidification. In approximately half of assessments, SBS symptom prevalences were significantly higher in buildings with simple mechanical ventilation than in buildings with natural ventilation. Insufficient information was available for conclusions about the potential increased risk of SBS symptoms with humidification. The statistically significant associations of mechanical ventilation and air conditioning with SBS symptoms are much more frequent than expected from chance and also not likely to be a consequence of confounding by several potential personal, job, or building related confounders. The reasons for the increases in symptom prevalences with mechanical ventilation and particularly with air conditioning remain unclear. Multiple deficiencies in HVAC system design, construction, operation, or maintenance, including some which cause pollutant emissions from HVAC systems, may contribute to the increases in symptom prevalences.

  3. Use of VOC sensors for air quality control of building ventilation systems

    National Research Council Canada - National Science Library

    M Großklos

    2015-01-01

    .... An air quality control was developed and tested in four single-family passive house dwellings to control the building ventilation system via VOC sensors and a special adaptation algorithm to handle...

  4. Research on risk long range identification for vessel traffic dynamic system

    Science.gov (United States)

    Qi, Ji; Guo, Ruijuan; Wang, Xiaoyu; Zhang, Hainan

    2017-09-01

    Vessel Long-range identification and tracking system has already been widely installed and applied in vessel. In this paper AIS system, vessel reporting system and LRIT in China are compared and analyzed based on the coverage area, confidentiality and accuracy of the LRIT information. Vessel Long-range identification and tracking model is established through a combination of AIS with LRIT system, which is applied to the research of vessel traffic dynamic system risk long range identification. Finally, the application of LRIT in the maritime field is discussed.

  5. In vitro growth and leaf anatomy of Cattleya walkeriana (Gardner, 1839 grown in natural ventilation system

    Directory of Open Access Journals (Sweden)

    Adriano Bortolotti da Silva

    2014-12-01

    Full Text Available Natural ventilation system facilitates gaseous exchanges in in vitro plants promoting changes in the leaf tissue, which can be evaluated through the leaf anatomy, and it allows a cultivation closer to the photoautrophic micropropagation. The objective of this work was to evaluate the effects on in vitro growth and on the leaf anatomy of Cattleya walkeriana grown in natural and conventional ventilation system with different concentrations of sucrose (0; 15; 30 and 45 L-1 combined with different cultivation systems (conventional micropropagation and natural ventilation system. The culture medium was composed of MS salts, solidified with 7 g L-1 of agar and pH adjusted to 5.8. Forty milliliters of culture medium were distributed in 250 mL flasks, autoclaved at 120 ºC for 20 minutes. The greater plant growth, as well as the greater thickness of the mesophyll was observed with the use of 20 g L-1 sucrose in natural ventilation system. Plants grown in natural ventilation system showed a thicker leaf mesophyll, which is directly related to photoautotrophic crops. The natural ventilation system induced more elliptical stomata and probably more functional formats.

  6. Project W-320 high vacuum 241-AY-102 annulus ventilation system operability test report

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.W.

    1998-03-12

    This report documents the test results of OTP-320-001, Tank 241-AY-102 Annulus Ventilation System Testing. Included in the appendices are: (1) Supporting documentation prepared to demonstrate the structural integrity of the tank at high annulus vacuum (<20 INWG), and (2) a report that identifies potential cross connections between the primary and annulus ventilation systems. These cross connections were verified to be eliminated prior to the start of testing.

  7. Study on pollution control in residential kitchen based on the push-pull ventilation system

    DEFF Research Database (Denmark)

    Zhou, Bin; Chen, Feng; Dong, Zhibo

    2016-01-01

    Highlights •The push-pull ventilation system is proposed to improve IAQ inside kitchen, where air is supplied through slot air curtain and then exhausted through range hood. •CO2 reduction efficiency with application of air curtain in experiment and simulation in breathing zone was 23.7% and 23.......1%, respectively. •By orthogonal method, the influence of factors on pollution control of the push-pull ventilation system was presented....

  8. Indoor temperatures for calculating room heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Olesen, Bjarne W.; Fang, Lei

    2016-01-01

    In this study, a typical office room with a radiant heating system and a mechanical ventilation system was selected as the research subject. Indoor temperature formulas for calculating the room heat loss (including transmission heat loss and ventilation heat loss) and heating capacity of the hybrid...... for calculating ventilation heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems. (C) 2015 Elsevier B.V. All rights reserved....... change rates on the indoor temperatures were performed using the proposed model. When heated surface temperatures and air change rates were from 21.0 to 29.0 degrees C and from 0.5 to 4.0 h-1, the indoor temperatures for calculating the transmission heat loss and ventilation heat loss were between 20...

  9. A novel system solution for cooling and ventilation in office buildings

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo

    2015-01-01

    technologies and renewable energy sources have risen. Based on a literature review of natural ventilation, building thermal mass activation and diffuse ceiling ventilation, this paper proposes a new system solution combining these three technologies for cooling and ventilation in office buildings. This new......As a response to new energy policies in the building sector, office buildings have become well-insulated and highly-airtight, resulting in an increasing cooling need both in summer and in winter. In order to effectively save energy, new interests in cooling concepts using passive cooling...

  10. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Kazemi, Seyed Hossein; Ardkapan, Siamak Rahimi

    Ventilation is needed for diluting and removing the contaminants, odour and excess heat from the building interior. It is important that the inhabitants perceive the ventilated spaces as comfortable. Therefore, the supply air should reach all parts of the occupied zones. Troldtekt has been...... manufacturing perforated acoustic panels for the last 13 years. The panels can be used not only in applications related to acoustics but also as low pressure drop supply air diffusers, particularly in diffuse ceiling ventilation systems. The present study verifies on a theoretically level the performance...

  11. Change-over natural and mechanical ventilation system energy consumption in single-family buildings

    Science.gov (United States)

    Kostka, Maria; Szulgowska-Zgrzywa, Małgorzata

    2017-11-01

    The parameters of the outside air in Poland cause that in winter it is reasonable to use a mechanical ventilation equipped with a heat recovery exchanger. The time of spring, autumn, summer evenings and nights are often characterized by the parameters of the air, which allow for a natural ventilation and reduce the electricity consumption. The article presents the possibilities of energy consumption reduction for three energy standards of buildings located in Poland, ventilated by a change-over hybrid system. The analysis was prepared on the assumption that the air-to-water heat pump is the heat source for the buildings.

  12. Control system design for a continuous positive airway pressure ventilator

    Directory of Open Access Journals (Sweden)

    Chen Zheng-Long

    2012-02-01

    Full Text Available Abstract Continuous Positive Airway Pressure (CPAP ventilation remains a mainstay treatment for obstructive sleep apnea syndrome (OSAS. Good pressure stability and pressure reduction during exhalation are of major importance to ensure clinical efficacy and comfort of CPAP therapy. In this study an experimental CPAP ventilator was constructed using an application-specific CPAP blower/motor assembly and a microprocessor. To minimize pressure variations caused by spontaneous breathing as well as the uncomfortable feeling of exhaling against positive pressure, we developed a composite control approach including the feed forward compensator and feedback proportional-integral-derivative (PID compensator to regulate the pressure delivered to OSAS patients. The Ziegler and Nichols method was used to tune PID controller parameters. And then we used a gas flow analyzer (VT PLUS HF to test pressure curves, flow curves and pressure-volume loops for the proposed CPAP ventilator. The results showed that it met technical criteria for sleep apnea breathing therapy equipment. Finally, the study made a quantitative comparison of pressure stability between the experimental CPAP ventilator and commercially available CPAP devices.

  13. Ion transport membrane module and vessel system with directed internal gas flow

    Science.gov (United States)

    Holmes, Michael Jerome; Ohrn, Theodore R.; Chen, Christopher Ming-Poh

    2010-02-09

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an inlet adapted to introduce gas into the interior of the vessel, an outlet adapted to withdraw gas from the interior of the vessel, and an axis; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region; and (c) one or more gas flow control partitions disposed in the interior of the pressure vessel and adapted to change a direction of gas flow within the vessel.

  14. Measuring Residential Ventilation System Airflows: Part 1 – Laboratory Evaluation of Airflow Meter Devices

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, J. Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Turner, W. J. N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Wray, Craig P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division

    2012-11-12

    Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must be measured so that energy is not wasted with over ventilation and occupants’ health is not compromised by under ventilation. Flow hoods are used to measure these ventilation flows, but there is currently no standard specifying the measurement procedure and measurement devices that should be used. This study evaluates the accuracy of six commercially available flow hoods under laboratory conditions configured to emulate a residential mechanical ventilation duct system. The measurements taken with the flow hoods were compared to simultaneous measurements taken by an in-line reference flow meter having a known uncertainty. Results indicate that powered flow hoods yield more accurate measurements than non-powered flow hoods, and that a majority of the flow hoods measured inlet flows more accurately than outlet flows. In several cases, there was little resemblance between the manufacturers’ stated accuracy and the accuracy we found in our laboratory measurements. It is clear that current flow hood calibration procedures may not consider field application variables such as flow asymmetry, flow angle, and flow direction. A new flow hood measurement standard that takes these ‘real world’ conditions into account should be developed to ensure that residential buildings receive the intended ventilation flows.

  15. Measuring Residential Ventilation System Airflows: Part 1 – Laboratory Evaluation of Airflow Meter Devices

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, J. Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Turner, W. J. N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Wray, Craig P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division

    2012-11-30

    Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must be measured so that energy is not wasted with over ventilation and occupants’ health is not compromised by under ventilation. Flow hoods are used to measure these ventilation flows, but there is currently no standard specifying the measurement procedure and measurement devices that should be used. This study evaluates the accuracy of six commercially available flow hoods under laboratory conditions configured to emulate a residential mechanical ventilation duct system. The measurements taken with the flow hoods were compared to simultaneous measurements taken by an in-line reference flow meter having a known uncertainty. Results indicate that powered flow hoods yield more accurate measurements than non-powered flow hoods, and that a majority of the flow hoods measured inlet flows more accurately than outlet flows. In several cases, there was little resemblance between the manufacturers’ stated accuracy and the accuracy we found in our laboratory measurements. It is clear that current flow hood calibration procedures may not consider field application variables such as flow asymmetry, flow angle, and flow direction. A new flow hood measurement standard that takes these ‘real world’ conditions into account should be developed to ensure that residential buildings receive the intended ventilation flows.

  16. A new system for continuous and remote monitoring of patients receiving home mechanical ventilation

    Science.gov (United States)

    Battista, L.

    2016-09-01

    Home mechanical ventilation is the treatment of patients with respiratory failure or insufficiency by means of a mechanical ventilator at a patient's home. In order to allow remote patient monitoring, several tele-monitoring systems have been introduced in the last few years. However, most of them usually do not allow real-time services, as they have their own proprietary communication protocol implemented and some ventilation parameters are not always measured. Moreover, they monitor only some breaths during the whole day, despite the fact that a patient's respiratory state may change continuously during the day. In order to reduce the above drawbacks, this work reports the development of a novel remote monitoring system for long-term, home-based ventilation therapy; the proposed system allows for continuous monitoring of the main physical quantities involved during home-care ventilation (e.g., differential pressure, volume, and air flow rate) and is developed in order to allow observations of different remote therapy units located in different places of a city, region, or country. The developed remote patient monitoring system is able to detect various clinical events (e.g., events of tube disconnection and sleep apnea events) and has been successfully tested by means of experimental tests carried out with pulmonary ventilators typically used to support sick patients.

  17. Ventilation patterns of the songbird lung/air sac system during different behaviors.

    Science.gov (United States)

    Mackelprang, Rebecca; Goller, Franz

    2013-10-01

    Unidirectional, continuous airflow through the avian lung is achieved through an elaborate air sac system with a sequential, posterior to anterior ventilation pattern. This classical model was established through various approaches spanning passively ventilated systems to mass spectrometry analysis of tracer gas flow into various air sacs during spontaneous breathing in restrained ducks. Information on flow patterns in other bird taxa is missing, and these techniques do not permit direct tests of whether the basic flow pattern can change during different behaviors. Here we use thermistors implanted into various locations of the respiratory system to detect small pulses of tracer gas (helium) to reconstruct airflow patterns in quietly breathing and behaving (calling, wing flapping) songbirds (zebra finch and yellow-headed blackbird). The results illustrate that the basic pattern of airflow in these two species is largely consistent with the model. However, two notable differences emerged. First, some tracer gas arrived in the anterior set of air sacs during the inspiration during which it was inhaled, suggesting a more rapid throughput through the lung than previously assumed. Second, differences in ventilation between the two anterior air sacs emerged during calling and wing flapping, indicating that adjustments in the flow pattern occur during dynamic behaviors. It is unclear whether this modulation in ventilation pattern is passive or active. This technique for studying ventilation patterns during dynamic behaviors proves useful for establishing detailed timing of airflow and modulation of ventilation in the avian respiratory system.

  18. Alternatives generation and analysis for double-shell tank primary ventilation systems emissions control and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    SEDERBURG, J.P.

    1999-09-30

    This AGA addresses the question: ''What equipment upgrades, operational changes, and/or other actions are required relative to the DST tanks farms' ventilation systems to support retrieval, staging (including feed sampling), and delivery of tank waste to the Phase I private contractor?'' Issues and options for the various components within the ventilation subsystem affect each other. Recommended design requirements are presented and the preferred alternatives are detailed.

  19. Some approaches to improve the ventilation system in underground potash mines

    OpenAIRE

    Bascompta Massanes, Marc

    2016-01-01

    Mine ventilation is a crucial factor for the sake of underground operations. Not only does it affect efficiency and effectiveness rates, but it also influence the health and safety of the employees. Despite it is a topic thoroughly analysed, every mine has its particularities and there is not much specific information concerning potash mines currently. This thesis investigates the main characteristics of the ventilation system in two potash mines, using a room and pillar method, with the i...

  20. Active cooling system for Tokamak in-vessel operation manipulator

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Jianjun, E-mail: yuanjj@sjtu.edu.cn; Chen, Tan; Li, Fashe; Zhang, Weijun; Du, Liang

    2015-10-15

    Highlights: • We summarized most of the challenges of fusion devices to robot systems. • Propose an active cooling system to protect all of the necessary components. • Trial design test and theoretical analysis were conducted. • Overall implementation of the active cooling system was demonstrated. - Abstract: In-vessel operation/inspection is an indispensable task for Tokamak experimental reactor, for a robot/manipulator is more capable in doing this than human being with more precise motion and less risk of damaging the ambient equipment. Considering the demanding conditions of Tokamak, the manipulator should be adaptable to rapid response in the extreme conditions such as high temperature, vacuum and so on. In this paper, we propose an active cooling system embedded into such manipulator. Cameras, motors, gearboxes, sensors, and other mechanical/electrical components could then be designed under ordinary conditions. The cooling system cannot only be a thermal shield since the components are also heat sources in dynamics. We carry out a trial test to verify our proposal, and analyze the active cooling system theoretically, which gives a direction on the optimization by varying design parameters, components and distribution. And based on thermal sensors monitoring and water flow adjusting a closed-loop feedback control of temperature is added to the system. With the preliminary results, we believe that the proposal gives a way to robust and inexpensive design in extreme environment. Further work will concentrate on overall implementation and evaluation of this cooling system with the whole inspection manipulator.

  1. 50 CFR 300.116 - Requirements for a vessel monitoring system for U.S. vessels.

    Science.gov (United States)

    2010-10-01

    ... procedures indicated on an installation and activation checklist, which is available from OLE; and (2) Submit to OLE a statement certifying compliance with the checklist, as prescribed on the checklist. (c... instructions from that office. If notified by NMFS that a vessel's VMS is not operating properly, the owner and...

  2. Mobile zone, spray booth ventilation system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-26

    This concept endeavors to reduce the volume of air (to be treated) from spray paint booths, thereby increasing efficiency and improving air pollution abatement (VOC emissions especially). Most of the ventilation air is recycled through the booth to maintain laminar flow; the machinery is located on the supply side of the booth rather than on the exhaust side. 60 to 95% reduction in spray booth exhaust rate should result. Although engineering and production prototypes have been made, demand is low.

  3. VENTILATION NEEDS DURING CONSTRUCTION

    Energy Technology Data Exchange (ETDEWEB)

    C.R. Gorrell

    1998-07-23

    The purpose of this analysis is to determine ventilation needs during construction and development of the subsurface repository and develop systems to satisfy those needs. For this analysis, construction is defined as pre-emplacement excavation and development is excavation that takes place simultaneously with emplacement. The three options presented in the ''Overall Development and Emplacement Ventilation Systems'' analysis (Reference 5.5) for development ventilation will be applied to construction ventilation in this analysis as well as adding new and updated ventilation factors to each option for both construction and development. The objective of this analysis is to develop a preferred ventilation system to support License Application Design. The scope of this analysis includes: (1) Description of ventilation conditions; (2) Ventilation factors (fire hazards, dust control, construction logistics, and monitoring and control systems); (3) Local ventilation alternatives; (4) Global ventilation options; and (5) Evaluation of options.

  4. An in situ optical imaging system for measuring lipid uptake, vessel contraction, and lymph flow in small animal lymphatic vessels

    Science.gov (United States)

    Kassis, Timothy; Weiler, Michael J.; Dixon, J. Brandon

    2012-03-01

    All dietary lipids are transported to venous circulation through the lymphatic system, yet the underlying mechanisms that regulate this process remain unclear. Understanding how the lymphatics functionally respond to changes in lipid load is important in the diagnosis and treatment of lipid and lymphatic related diseases such as obesity, hypercholesterolemia, and lymphedema. Therefore, we sought to develop an in situ imaging system to quantify and correlate lymphatic function as it relates to lipid transport. A custom-built optical set-up provides us with the capability of dual-channel imaging of both high-speed bright-field video and fluorescence simultaneously. This is achieved by dividing the light path into two optical bands. Utilizing high-speed and back-illuminated CCD cameras and post-acquisition image processing algorithms, we have the potential quantify correlations between vessel contraction, lymph flow and lipid concentration of mesenteric lymphatic vessels in situ. Local flow velocity is measured through lymphocyte tracking, vessel contraction through measurements of the vessel walls and lipid uptake through fluorescence intensity tracking of a fluorescent long chain fatty acid analogue, Bodipy FL C16. This system will prove to be an invaluable tool for both scientists studying lymphatic function in health and disease, and those investigating strategies for targeting the lymphatic system with orally delivered drugs.

  5. Economizer system cost effectiveness: Accounting for the influence of ventilation rate on sick leave

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Seppanen, Olli; Faulkner, David; Huang, Joe

    2003-06-01

    This study estimated the health, energy, and economic benefits of an economizer ventilation control system that increases outside air supply during mild weather to save energy. A model of the influence of ventilation rate on airborne transmission of respiratory illnesses was used to extend the limited data relating ventilation rate with illness and sick leave. An energy simulation model calculated ventilation rates and energy use versus time for an office building in Washington, DC with fixed minimum outdoor air supply rates, with and without an economizer. Sick leave rates were estimated with the disease transmission model. In the modeled 72-person office building, our analyses indicate that the economizer reduces energy costs by approximately $2000 and, in addition, reduces sick leave. The financial benefit of the decrease in sick leave is estimated to be between $6,000 and $16,000. This modelling suggests that economizers are much more cost effective than currently recognized.

  6. Assessment of Pollutant Spread from a Building Basement with three Ventilation Systems

    CERN Document Server

    Koffi, Juslin

    2010-01-01

    Ventilation aims at providing a sufficient air renewal for ensuring a good indoor air quality (IAQ), yet building energy policies are leading to adapting various ventilation strategies minimising energy losses through air renewal. A recent IAQ evaluation campaign in French dwellings shows important pollution of living spaces by VOCs such as formaldehyde, acetaldehyde or hexanal, particularly in buildings equipped with a garage. Besides, radon emission from soil is a subject of concern in many countries. Several studies are done to understand its release mode and deal with the spread of this carcinogen gas. This paper aims to experimentally assess a contaminant spread from a house basement using mechanical exhaust and balanced ventilation systems, and natural ventilation.

  7. Modelling of pressure increase protection system for the vacuum vessel of W7-X device

    Energy Technology Data Exchange (ETDEWEB)

    Kaliatka, Tadas, E-mail: tadas.kaliatka@lei.lt; Uspuras, Eugenijus; Kaliatka, Algirdas

    2016-11-01

    Highlights: • Two in-vessel LOCAs (partial and guillotine break of 40 mm diameter pipe of cooling system) for Wendelstein 7-X fusion device were analyzed. • The analysis of the processes in the cooling system, vacuum vessel and pressure increase protection system were performed using thermal-hydraulic RELAP5 Mod3.3 code. • The suitability of pressure increase protection system was assessed. - Abstract: In fusion devices, plasma is contained in a vacuum vessel. The vacuum vessel cannot withstand a pressure above atmospheric. Any damage of in-vessel components could lead to water ingress and may lead to pressure increase and possible damage of vacuum vessel. In order to avoid such undesirable consequences, the pressure increase protection system is designed. In this article, the processes occurring in the vacuum vessel and pressure increase protection system of W7-X device during LOCA (small and guillotine pipe break) event are analyzed. The model of W7-X cooling system, vacuum vessel and pressure increase protection system was developed using RELAP5 code. Numerical analysis of partial and guillotine break of 40 mm diameter pipe of cooling system was performed. Calculation results showed that burst disc of the pressure increase protection system does not open when the cross section area of partial break in the cooling system is smaller than 1 mm{sup 2}. During the guillotine break of cooling system, the burst disc opens, but pressure increase protection system is capable to prevent overpressure of the vacuum vessel.

  8. PV Systems Installed in Marine Vessels: Technologies and Specifications

    Directory of Open Access Journals (Sweden)

    Ioannis Kobougias

    2013-01-01

    Full Text Available Considerations are held about the specificationin whichthe PV plants have to fulfill so that they can be installed on marine vessels. Initially, a brief description of the typical electrical grid of ships is presented, distinguishing the main parts, reporting the typical electrical magnitudes, and choosing the most preferable installation areas. The technical specifications,in whichthe PV plants have to be compatible with, are fully described. They are determined by the special marine environmental conditions, taking into consideration parameters like wind, humidity, shading, corrosion, and limited installation area. The work is carried out with the presentation of the most popular trends in the field of solar cell types and PV system technologies and their ability to keep up with the aforementioned specifications.

  9. Design Principles for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system -Hybrid Ventilation. ....... The hybrid ventilation concepts, design challenges and - principles are discussed and illustrated by four building examples....

  10. 46 CFR 69.11 - Determining the measurement system or systems for a particular vessel.

    Science.gov (United States)

    2010-10-01

    ... Measurement System, for applying the International Convention for the Safety of Life at Sea (SOLAS), the... system or systems for a particular vessel. (a) Convention Measurement System (subpart B). (1) Except as... construction before January 1, 1986, unless the owner requests measurement under the Convention Measurement...

  11. Dynamic Characteristics of Mechanical Ventilation System of Double Lungs with Bi-Level Positive Airway Pressure Model

    Directory of Open Access Journals (Sweden)

    Dongkai Shen

    2016-01-01

    Full Text Available In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics.

  12. Combining a building simulation with energy systems analysis to assess the benefits of natural ventilation

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg; Remmen, Arne

    2013-01-01

    a thermal air flow simulation program - Into the energy systems analysis model. Descriptions of the energy systems in two geographical locations, i.e. Mexico and Denmark, are set up as inputs. Then, the assessment is done by calculating the energy impacts as well as environmental benefits in the energy......This article shows the combination of a thermal air flow simulation program with an energy systems analysis model in order to assess the use of natural ventilation as a method for saving energy within residential buildings in large-scale scenarios. The aim is to show the benefits for utilizing...... natural airflow instead of active systems such as mechanical ventilation or air-conditioning in buildings where the indoor temperature is over the upper limit of the comfort range. The combination is done by introducing the energy saving output - calculated with a model of natural ventilation using...

  13. 76 FR 36071 - Atlantic Highly Migratory Species; Vessel Monitoring Systems

    Science.gov (United States)

    2011-06-21

    ... agents have also reported difficulty communicating with vessels when needed, such as when closed areas... professionally installed and used to replace the dated MTU VMS units, NMFS will ensure that newer, more reliable... enforcement agents with the ability to communicate directly with vessels at sea via electronic messaging and...

  14. 76 FR 75492 - Atlantic Highly Migratory Species; Vessel Monitoring Systems

    Science.gov (United States)

    2011-12-02

    ... rather than cell towers as the principle means of transmitting data. Furthermore, vessels need to provide position reports every hour when they are away from port, and cell phones cannot consistently provide that... and fishing gears possessed to be made by phone. Some small fishing vessels remain within cell phone...

  15. Ventilator graphics.

    Science.gov (United States)

    Prabhakaran, Priya; Sasser, William C; Kalra, Yuvrai; Rutledge, Chrystal; Tofil, Nancy M

    2016-12-01

    Providing optimal mechanical ventilation to critically-ill children remains a challenge. Patient-ventilator dyssynchrony results frequently with numerous deleterious consequences on patient outcome including increased requirement for sedation, prolonged duration of ventilation, and greater imposed work of breathing. Most currently used ventilators have real-time, continuously-displayed graphics of pressure, volume, and flow versus time (scalars) as well as pressure, and flow versus volume (loops). A clear understanding of these graphics provides a lot of information about the mechanics of the respiratory system and the patient ventilator interaction in a dynamic fashion. Using this information will facilitate tailoring the support provided and the manner in which it is provided to best suit the dynamic needs of the patient. This paper starts with a description of the scalars and loops followed by a discussion of the information that can be obtained from each of these graphics. A review will follow, on the common types of dyssynchronous interactions and how each of these can be detected on the ventilator graphics. The final section discusses how graphics can be used to optimize the ventilator support provided to patients.

  16. Procedures and Standards for Residential Ventilation System Commissioning: An Annotated Bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, J. Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wray, Craig P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    Beginning with the 2008 version of Title 24, new homes in California must comply with ANSI/ASHRAE Standard 62.2-2007 requirements for residential ventilation. Where installed, the limited data available indicate that mechanical ventilation systems do not always perform optimally or even as many codes and forecasts predict. Commissioning such systems when they are installed or during subsequent building retrofits is a step towards eliminating deficiencies and optimizing the tradeoff between energy use and acceptable IAQ. Work funded by the California Energy Commission about a decade ago at Berkeley Lab documented procedures for residential commissioning, but did not focus on ventilation systems. Since then, standards and approaches for commissioning ventilation systems have been an active area of work in Europe. This report describes our efforts to collect new literature on commissioning procedures and to identify information that can be used to support the future development of residential-ventilation-specific procedures and standards. We recommend that a standardized commissioning process and a commissioning guide for practitioners be developed, along with a combined energy and IAQ benefit assessment standard and tool, and a diagnostic guide for estimating continuous pollutant emission rates of concern in residences (including a database that lists emission test data for commercially-available labeled products).

  17. Split-bolus MR urography: synchronous visualization of obstructing vessels and collecting system in children

    National Research Council Canada - National Science Library

    Bilal Battal; Murat Kocaoglu; Veysel Akgün; Selami Ince; Faysal Gök; Mustafa Tasar

    2015-01-01

      Several vascular abnormalities related with urinary system such as crossing accessory renal vessels, retroiliac ureters, retrocaval ureters, posterior nutcracker syndrome, and ovarian vein syndrome...

  18. The influence of an estimated energy saving due to natural ventilation on the Mexican energy system

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2014-01-01

    This article shows the impacts of the extensive use of NV (natural ventilation) in the Mexican residential sector on the Mexican energy system. By integrating a thermal-airflow simulation programme with an energy systems analysis model, the impact on the Mexican energy system of replacing air...... conditioning, in particular, with natural ventilation to cool residential buildings is determined. It is shown that when, as in Mexico, there is a relatively simple connection between supply and electricity demand, NV creates savings which could be used to reduce either the fossil-fuel-based generation...

  19. Numerical Field Model Simulation of Full-Scale Fire Tests in a Closed Spherical/Cylindrical Vessel with Internal Ventilation

    Science.gov (United States)

    1988-09-01

    tional speed and massive storage capability, offer a researcher the option of computer modeling of fires. The systems of partial differen- tial...SMP123+SMPP12 i’.S 00101800 RI(I,JK I=-BUOY* DROGA /(RtI,J,K)*STRAIN) 00101900 ABRIPR:ABTURB+RI(I ,J,K )/PRT 00102000 IF(AF’.IPR .LT. 0.) GO TO b00 00102100

  20. A perfluorochemical loss/restoration (L/R) system for tidal liquid ventilation.

    Science.gov (United States)

    Libros, R; Philips, C M; Wolfson, M R; Shaffer, T H

    2000-01-01

    Tidal liquid ventilation is the transport of dissolved respiratory gases via volume exchange of perfluorochemical (PFC) liquid to and from the PFC-filled lung. All gas-liquid surface tension is eliminated, increasing compliance and providing lung protection due to lower inflation pressures. Tidal liquid ventilation is achieved by cycling fluid from a reservoir to and from the lung by a ventilator. Current approaches are microprocessor-based with feedback control. During inspiration, warmed oxygenated PFC liquid is pumped from a fluid reservoir/gas exchanger into the lung. PFC fluid is conserved by condensing (60-80% efficiency) vapor in the expired gas. A feedback-control system was developed to automatically replace PFC lost due to condenser inefficiency. This loss/restoration (L/R) system consists of a PFC-vapor thermal detector (+/- 2.5%), pneumatics, amplifiers, a gas flow detector (+/- 1%), a PFC pump (+/- 5%), and a controller. Gravimetric studies of perflubron loss from a flask due to evaporation were compared with experimental L/R results and found to be within +/- 1.4%. In addition, when L/R studies were conducted with a previously reported liquid ventilation system over a four-hour period, the L/R system maintained system perflubron volume to within +/- 1% of prime volume and 11.5% of replacement volume, and the difference between experimental PFC loss and that of the L/R system was 1.8 mL/hr. These studies suggest that the PFC L/R system may have significant economic (appropriate dosing for PFC loss) as well as physiologic (maintenance of PFC inventory in the lungs and liquid ventilator) impact on liquid ventilation procedures.

  1. Assessment of Natural Ventilation System for a Typical Residential House in Poland

    Science.gov (United States)

    Antczak-Jarząbska, Romana; Krzaczek, Marek

    2016-09-01

    The paper presents the research results of field measurements campaign of natural ventilation performance and effectiveness in a residential building. The building is located in the microclimate whose parameters differ significantly in relation to a representative weather station. The measurement system recorded climate parameters and the physical variables characterizing the air flow in the rooms within 14 days of the winter season. The measurement results showed that in spite of proper design and construction of the ventilation system, unfavorable microclimatic conditions that differed from the predicted ones caused significant reduction in the efficiency of the ventilation system. Also, during some time periods, external climate conditions caused an opposite air flow direction in the vent inlets and outlets, leading to a significant deterioration of air quality and thermal comfort measured by CO2 concentration and PMV index in a residential area.

  2. Parameter estimation of an artificial respiratory system under mechanical ventilation following a noisy regime

    Directory of Open Access Journals (Sweden)

    Marcus Henrique Victor Júnior

    Full Text Available Abstract Introduction: This work concerns the assessment of a novel system for mechanical ventilation and a parameter estimation method in a bench test. The tested system was based on a commercial mechanical ventilator and a personal computer. A computational routine was developed do drive the mechanical ventilator and a parameter estimation method was utilized to estimate positive end-expiratory pressure, resistance and compliance of the artificial respiratory system. Methods The computational routine was responsible for establishing connections between devices and controlling them. Parameters such as tidal volume, respiratory rate and others can be set for standard and noisy ventilation regimes. Ventilation tests were performed directly varying parameters in the system. Readings from a calibrated measuring device were the basis for analysis. Adopting a first-order linear model, the parameters could be estimated and the outcomes statistically analysed. Results Data acquisition was effective in terms of sample frequency and low noise content. After filtering, cycle detection and estimation took place. Statistics of median, mean and standard deviation were calculated, showing consistent matching with adjusted values. Changes in positive end-expiratory pressure statistically imply changes in compliance, but not the opposite. Conclusion The developed system was satisfactory in terms of clinical parameters. Statistics exhibited consistent relations between adjusted and estimated values, besides precision of the measurements. The system is expected to be used in animals, with a view to better understand the benefits of noisy ventilation, by evaluating the estimated parameters and performing cross relations among blood gas, ultrasonography and electrical impedance tomography.

  3. Microprocessor-controlled ventilation system in the House of German-Soviet Friendship in Dresden

    Energy Technology Data Exchange (ETDEWEB)

    Naumann, B.

    1983-01-01

    A description is given of the use of a universal programmable PS 2000 control system and peripherals in a prototype project to control ventilation systems. Reference is made to the partial operations, of control and monitoring of the fan and pump drives, multi-channel governors, actuator control and automatic timing. New problems occurring in preparation and implementation are outlined.

  4. The Design and Simulation of Natural Personalised Ventilation (NPV System for Multi-Bed Hospital Wards

    Directory of Open Access Journals (Sweden)

    Zulfikar A. Adamu

    2015-05-01

    Full Text Available Adequate ventilation is necessary for thermal comfort and reducing risks from infectious bio-aerosols in hospital wards, but achieving this with mechanical ventilation has carbon and energy implications. Natural ventilation is often limited to window-based designs whose dilution/mixing effectiveness are subject to constraints of wind speed, cross ventilation, and in the case of hospital wards, proximity of patients to external walls. A buoyancy-driven natural ventilation system capable of achieving dilution/mixing was shown to be feasible in a preceding study of novel system called natural personalised ventilation (NPV. This system combined both architecture and airflow engineering principles of space design and buoyancy and was tested and validated (salt-bath experiment for a single bed ward. This research extends the previous work and is proof-of-concept on the feasibility of NPV system for multi-bed wards. Two different four-bed ward types were investigated of using computational fluid dynamics (CFD simulations under wind-neutral conditions. Results predict that NPV system could deliver fresh air to multiple patients, including those located 10 m away from external wall, with absolute flow rates of between 32 L·s−1 and 54 L·s−1 for each patient/bed. Compared to same wards simulated using window design, ingress of airborne contaminants into patients’ breathing zone and summer overheating potential were minimised, while overall ward dilution was maximised. Findings suggest the NPV has potentials for enabling architects and building service engineers to decouple airflow delivery from the visualisation and illumination responsibilities placed upon windows.

  5. ADMINISTRATIVE AND ENGINEERING CONTROLS FOR THE OPERATION OF VENTILATION SYSTEMS FOR UNDERGROUND RADIOACTIVE WASTE STORAGE TANKS

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, B.; Hansen, A.

    2013-11-13

    Liquid radioactive wastes from the Savannah River Site are stored in large underground carbon steel tanks. The majority of the waste is confined in double shell tanks, which have a primary shell, where the waste is stored, and a secondary shell, which creates an annular region between the two shells, that provides secondary containment and leak detection capabilities should leakage from the primary shell occur. Each of the DST is equipped with a purge ventilation system for the interior of the primary shell and annulus ventilation system for the secondary containment. Administrative flammability controls require continuous ventilation to remove hydrogen gas and other vapors from the waste tanks while preventing the release of radionuclides to the atmosphere. Should a leak from the primary to the annulus occur, the annulus ventilation would also serve this purpose. The functionality of the annulus ventilation is necessary to preserve the structural integrity of the primary shell and the secondary. An administrative corrosion control program is in place to ensure integrity of the tank. Given the critical functions of the purge and annulus ventilation systems, engineering controls are also necessary to ensure that the systems remain robust. The system consists of components that are constructed of metal (e.g., steel, stainless steel, aluminum, copper, etc.) and/or polymeric (polypropylene, polyethylene, silicone, polyurethane, etc.) materials. The performance of these materials in anticipated service environments (e.g., normal waste storage, waste removal, etc.) was evaluated. The most aggressive vapor space environment occurs during chemical cleaning of the residual heels by utilizing oxalic acid. The presence of NO{sub x} and mercury in the vapors generated from the process could potentially accelerate the degradation of aluminum, carbon steel, and copper. Once identified, the most susceptible materials were either replaced and/or plans for discontinuing operations

  6. Cleanup and Dismantling of Highly Contaminated Ventilation Systems Using Robotic Tools - 13162

    Energy Technology Data Exchange (ETDEWEB)

    Chambon, Frederic [AREVA FEDERAL SERVICES, Columbia MD (United States); CIZEL, Jean-Pierre [AREVA BE/NV, Marcoule (France); Blanchard, Samuel [CEA DEN/DPAD, Marcoule (France)

    2013-07-01

    The UP1 plant reprocessed nearly 20,000 tons of used natural uranium gas cooled reactor fuel coming from the first generation of civil nuclear reactors in France. Following operating incidents in the eighties, the ventilation system of the continuous dissolution line facility was shut down and replaced. Two types of remote controlled tool carriers were developed to perform the decontamination and dismantling operations of the highly contaminated ventilation duct network. The first one, a dedicated small robot, was designed from scratch to retrieve a thick powder deposit within a duct. The robot, managed and confined by two dedicated glove boxes, was equipped for intervention inside the ventilation duct and used for carrying various cleanup and inspection tools. The second type, consisting of robotic tools developed on the base of an industrial platform, was used for the clean-up and dismantling of the ventilation duct system. Depending on the type of work to be performed, on the shape constraints of the rooms and any equipment to be dismantled, different kinds of robotic tools were developed and installed on a Brokk 40 carrier. After more than ten years of ventilation duct D and D operations at the UP1 plant, a lot of experience was acquired about remote operations. The three main important lessons learned in terms of remote controlled operation are: characterizing the initial conditions as much as reasonably possible, performing non-radioactive full scale testing and making it as simple and modular as possible. (authors)

  7. CFD-based design of the ventilation system for the PHENIX detector

    Energy Technology Data Exchange (ETDEWEB)

    Parietti, L.; Martin, R.A.; Gregory, W.S.

    1996-10-01

    The three-dimensional flow and thermal fields surrounding the large PHENIX sub-atomic particle detector enclosed in the Major Facility Hall are simulated numerically in this study using the CFX finite volume, commercial, computer code. The predicted fields result from the interaction of an imposed downward ventilation system cooling flow and a buoyancy-driven thermal plume rising from the warm detector. An understanding of the thermal irregularities on the surface of the detector and in the flow surrounding is needed to assess the potential for adverse thermal expansion effects in detector subsystems, and to prevent ingestion of electronics cooling air from hot spots. With a computational model of the thermal fields on and surrounding the detector, HVAC engineers can evaluate and improve the ventilation system design prior to the start of construction. This paper summarizes modeling and results obtained for a conceptual MFH ventilation scheme.

  8. Experimental Evaluation of Ventilation Systems in a Single-Family Dwelling

    CERN Document Server

    Koffi, Juslin; Akoua, Jean-Jacques

    2010-01-01

    The French regulation on residential building ventilation relies on an overall and continuous air renewal. The fresh air should enter the building through the "habitable rooms" while the polluted air is extracted in the service rooms. In this way, internal air is drained from the lowest polluted rooms to the highest polluted ones. However, internal pressure equilibrium and air movements in buildings result from the combined effects ventilation system and parameters such as wind, temperature difference or doors opening. This paper aims to analyse the influence of these parameters on pollutant transfer within buildings. In so doing, experiments are carried out using tracer gas release for representing pollution sources in an experimental house. Mechanical exhaust, balanced and natural ventilation systems are thus tested. Results show the followings: - For all cases, internal doors' opening causes the most important pollutant spread. - When doors are closed, the best performances are obtained with balanced venti...

  9. AUTOPILOT-BT: a system for knowledge and model based mechanical ventilation.

    Science.gov (United States)

    Lozano, S; Möller, K; Brendle, A; Gottlieb, D; Schumann, S; Stahl, C A; Guttmann, J

    2008-01-01

    A closed-loop system (AUTOPILOT-BT) for the control of mechanical ventilation was designed to: 1) autonomously achieve goals specified by the clinician, 2) optimize the ventilator settings with respect to the underlying disease and 3) automatically adapt to the individual properties and specific disease status of the patient. The current realization focuses on arterial oxygen saturation (SpO(2)), end-tidal CO(2) pressure (P(et)CO(2)), and positive end-expiratory pressure (PEEP) maximizing respiratory system compliance (C(rs)). The "AUTOPILOT-BT" incorporates two different knowledge sources: a fuzzy logic control reflecting expert knowledge and a mathematical model based system that provides individualized patient specific information. A first evaluation test with respect to desired end-tidal-CO(2)-level was accomplished using an experimental setup to simulate three different metabolic CO(2) production rates by means of a physical lung simulator. The outcome of ventilator settings made by the "AUTOPILOT-BT" system was compared to those produced by clinicians. The model based control system proved to be superior to the clinicians as well as to a pure fuzzy logic based control with respect to precision and required settling time into the optimal ventilation state.

  10. The effect of a personalized ventilation system on perceived air quality and SBS symptoms

    DEFF Research Database (Denmark)

    Kaczmarczyk, Jan; Zeng, Q.; Melikov, Arsen Krikor

    2002-01-01

    Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled....... Subjects participated in four experiments: (1) PVS supplying outdoor air at 20 deg.C; (2) PVS supplying outdoor air at 23 deg.C; (3) PVS supplying recirculated room air; and (4) mixing ventilation. Room temperature was kept constant at 23 deg.C and relative humidity at 30%. Results showed that the best...

  11. Development of mechanical ventilation system with low energy consumption for renovation of buildings

    DEFF Research Database (Denmark)

    Terkildsen, Søren

    in reducing CO2-emmissions. Over the last decade, initiatives have been taken to reduce its energy consumption e.g. by the European Union, national governments or NGOs. The initiatives have mostly focused on improving the thermal properties of the building envelope to reduce heat losses. Building services......A general reduction in total energy consumption is needed, due to the increasing concerns about climate change caused by CO2-emmissions from fossil fuels. In 2004, the building sector accounted for 40% of the total energy consumption in the EU and the US and therefore must play a crucial role......, including ventilation, therefore now represent a larger part of the total energy consumption. Mechanical ventilation has been the most widely used principle of ventilation over the last 50 years, but the conventional system design needs revising to meet future energy requirements. The increase in the use...

  12. Automated Control of Shipboard Ventilation Systems: Phase 2 Part B Test Results (CD-ROM)

    Science.gov (United States)

    Smoke Control Dampers and fourteen Smoke Purge Dampers. Most of the ventilation terminals serve the Main and 2nd Decks, and to a lesser extent, the 01 Level and 03 Decks. Under the existing control system, the SES system is capable of two modes of operation, Collective Protection System (CPS) and SES. These two modes were replaced by a single automated mode, AUTO mode. This system takes its cues from sensors and automatically goes to smoke ejection under fire and smoke

  13. Design, Implementation & Assessment of Local Exhaust Ventilation System and dust collectors for crushing unit

    Directory of Open Access Journals (Sweden)

    Farshid Ghorbani shahna

    2015-09-01

    Full Text Available Background & objective: Industrial ventilation systems and dust collectors are effective solutions to reduce particulate emissions in the workplace and environmental in mineral processes. In this study, Local Exhaust Ventilation System and dust collectors for control of emitted silica, coke, silicon carbide dusts from crushing unit was designed and evaluated. Methods: : Local Exhaust ventilation system based on standards and guides was designed and implemented after field study of the processes and sources of air pollutants. A set comprised of the four parallel cyclones (Stairmand model and a new design of the scrubber had been used for dust control. After set-up of systems, its effectiveness in reducing the exposure of workers in the workshops and dust collecting were assessed. Results: Test results were significant differences between the concentration of particles in both on and off the ventilation system revealed (P <0.05. The system has been implemented as means of personal exposure to pollutants and environmental emissions were reduced 93.01% and 64.64%, respectively. Also, alone and integrated collection efficiency of cyclone and scrubber, were 94.2%, 59.05% and 97.4%, respectively. The results show good agreement with the values of the parameters ventilation system was designed. Conclusion: Implementation of integrated dust collectors is a good option in industries that have the financial and technical constraints to improve change processes and devices. This method with attainment to health and environmental standards not only can be resolve of the pollution problems, but also will be economically justified of such projects with reduction of depreciation expense and dust recycling.

  14. Experimental study of a semi-passive ventilation grille with a feedback control system

    Science.gov (United States)

    D'Orazio, A.; Fontana, L.; Salata, F.

    2011-08-01

    The diffusion of window frames with low air permeability, due to the energy saving regulations, has implied in several cases the worsening of the indoor microclimate and air quality. On the other hand, air-tight window frames imply uncontrolled and too high air change rates. The mechanical ventilation not always is a practicable solution because of economic reasons and because it implies energy waste. Various Italian and European environmental and energetic laws take into consideration and promote the use of controlled natural ventilation, though this definition is not associated to well defined and tested technical solutions. An adequate solution can be achieved by using semi-passive self adjustable ventilation devices, able to ensure controlled changes of indoor air. In this paper, a semi-passive damper with a feedback control system is proposed and its behavior is investigated by means of experimental study. The presented semi-passive grille allows to control the air flow rate, injected into the room by natural or artificial pressure gradient, more effectively than the usual passive ventilation grilles made available by the present industrial production. However, since the semi-passive grille has a one-way flow, in the natural ventilation of a flat the proper functioning of the system could be ensured with a more complex configuration, with respect to the passive self-regulating grilles, able to limit the flow of fresh air in the presence of high levels of Δp; conversely, it could have widespread use in applications requiring a more accurate control of airflow in case of mechanical ventilation plants.

  15. Diffuse ceiling ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen

    Diffuse ceiling ventilation is an innovative ventilation concept where the suspended ceiling serves as air diffuser to supply fresh air into the room. Compared with conventional ventilation systems, diffuse ceiling ventilation can significantly reduce or even eliminate draught risk due to the low...... momentum supply. In addition, this ventilation system uses a ceiling plenum to deliver air and requires less energy consumption for air transport than full-ducted systems. There is a growing interest in applying diffuse ceiling ventilation in offices and other commercial buildings due to the benefits from...... both thermal comfort and energy efficient aspects. The present study aims to characterize the air distribution and thermal comfort in the rooms with diffuse ceiling ventilation. Both the stand-alone ventilation system and its integration with a radiant ceiling system are investigated. This study also...

  16. Experimental Study of an Integrated System with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per

    The experiments are carried out in a climate chamber located at the Department of Civil Engineering Aalborg University. The objective of the experiments is to evaluate the performance of the system combining diffuse ceiling ventilation and thermally activated building construction (TABS) in terms...

  17. A method for evaluating the problem complex of choosing the ventilation system for a new building

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2007-01-01

    The application of a ventilation system in a new building is a multidimensional complex problem that involves quantifiable and non-quantifiable data like energy consump¬tion, indoor environment, building integration and architectural expression. This paper presents a structured method for evaluat...

  18. Calculation notes in support of ammonia releases from waste tank ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Wojdac, L.F.

    1996-09-05

    Ammonia is generated in waste tanks via the degradation of nitrogen compounds. The ammonia is released from the liquids by a mechanism which is dependent on temperature, pH, ionic strength and ammonia concentration. The release of ammonia to the environment occurs via diffusion of ammonia through a stagnant air mass and into the ventilation system.

  19. The respiratory system during resuscitation: a review of the history, risk of infection during assisted ventilation, respiratory mechanics, and ventilation strategies for patients with an unprotected airway.

    Science.gov (United States)

    Wenzel, V; Idris, A H; Dörges, V; Nolan, J P; Parr, M J; Gabrielli, A; Stallinger, A; Lindner, K H; Baskett, P J

    2001-05-01

    The fear of acquiring infectious diseases has resulted in reluctance among healthcare professionals and the lay public to perform mouth-to-mouth ventilation. However, the benefit of basic life support for a patient in cardiopulmonary or respiratory arrest greatly outweighs the risk for secondary infection in the rescuer or the patient. The distribution of ventilation volume between lungs and stomach in the unprotected airway depends on patient variables such as lower oesophageal sphincter pressure, airway resistance and respiratory system compliance, and the technique applied while performing basic or advanced airway support, such as head position, inflation flow rate and time, which determine upper airway pressure. The combination of these variables determines gas distribution between the lungs and the oesophagus and subsequently, the stomach. During bag-valve-mask ventilation of patients in respiratory or cardiac arrest with oxygen supplementation (> or = 40% oxygen), a tidal volume of 6-7 ml kg(-1) ( approximately 500 ml) given over 1-2 s until the chest rises is recommended. For bag-valve-mask ventilation with room-air, a tidal volume of 10 ml kg(-1) (700-1000 ml) in an adult given over 2 s until the chest rises clearly is recommended. During mouth-to-mouth ventilation, a breath over 2 s sufficient to make the chest rise clearly (a tidal volume of approximately 10 ml kg(-1) approximately 700-1000 ml in an adult) is recommended.

  20. Positioning of sensors for control of ventilation systems in broiler houses: a case study

    Directory of Open Access Journals (Sweden)

    Thayla Morandi Ridolfi de Carvalho Curi

    Full Text Available ABSTRACT Ventilation systems are incorporated at intensive poultry farms to control environment conditions and thermal comfort of broilers. The ventilation system operates based on environmental data, particularly measured by sensors of temperature and relative humidity. Sensors are placed at different positions of the facility. Quality, number and positioning of the sensors are critical factors to achieve an efficient performance of the system. For this reason, a strategic positioning of the sensors associated to controllers could support the maintenance and management of the microclimate inside the facility. This research aims to identify the three most representative points for the positioning of sensors in order to support the ventilation system during the critical period from 12h00 to 15h00 on summer days. Temperature, relative humidity and wind speed were measured in four different tunnel ventilated barns at the final stage of the production cycle. The descriptive analysis was performed on these data. The Temperature and Humidity Index (THI was also calculated. Then, the geostatistical analysis of THI was performed by GS+ and the position of sensors was determined by ordinary kriging. The methodology was able to detect the most representative points for the positioning of sensors in a case study (southeastern Brazil. The results suggested that this strategic positioning would help controllers to obtain a better inference of the microclimate during the studied period (the hottest microclimate, considered critical in Brazil. In addition, these results allow developing a future road map for a decision support system based on 24 h monitoring of the ventilation systems in broiler houses.

  1. A novel fiber-optic measurement system for the evaluation of performances of neonatal pulmonary ventilators

    Science.gov (United States)

    Battista, L.; Scorza, A.; Botta, F.; Sciuto, S. A.

    2016-02-01

    Published standards for the performance evaluation of pulmonary ventilators are mainly directed to manufacturers rather than to end-users and often considered inadequate or not comprehensive. In order to contribute to overcome the problems above, a novel measurement system was proposed and tested with waveforms of mechanical ventilation by means of experimental trials carried out with infant ventilators typically used in neonatal intensive care units: the main quantities of mechanical ventilation in newborns are monitored, i.e. air flow rate, differential pressure and volume from infant ventilator are measured by means of two novel fiber-optic sensors (OFSs) developed and characterized by the authors, while temperature and relative humidity of air mass are obtained by two commercial transducers. The proposed fiber-optic sensors (flow sensor Q-OFS, pressure sensor P-OFS) showed measurement ranges of air flow and pressure typically encountered in neonatal mechanical ventilation, i.e. the air flow rate Q ranged from 3 l min-1 to 18 l min-1 (inspiratory) and from  -3 l min-1 to  -18 l min-1 (expiratory), the differential pressure ΔP ranged from  -15 cmH2O to 15 cmH2O. In each experimental trial carried out with different settings of the ventilator, outputs of the OFSs are compared with data from two reference sensors (reference flow sensor RF, reference pressure sensor RP) and results are found consistent: flow rate Q showed a maximum error between Q-OFS and RF up to 13 percent, with an output ratio Q RF/Q OFS of not more than 1.06  ±  0.09 (least square estimation, 95 percent confidence level, R 2 between 0.9822 and 0.9931). On the other hand the maximum error between P-OFS and RP on differential pressure ΔP was lower than 10 percent, with an output ratio ΔP RP/ΔP OFS between 0.977  ±  0.022 and 1.0  ±  0.8 (least square estimation, 95 percent confidence level, R 2 between 0.9864 and 0.9876). Despite the possible improvements

  2. ITER cryostat main chamber and vacuum vessel pressure suppression system design

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Akira; Nakahira, Masataka; Takahashi, Hiroyuki; Tada, Eisuke [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Nakashima, Yoshitane; Ueno, Osamu

    1999-03-01

    Design of Cryostat Main Chamber and Vacuum Vessel Pressure Suppression System (VVPS) of International Thermonuclear Experimental Reactor (ITER) has been conducted. The cryostat is a cylindrical vessel that includes in-vessel component such as vacuum vessel, superconducting toroidal coils and poloidal coils. This cryostat provides the adiabatic vacuum about 10{sup -4} Pa for the superconducting coils operating at 4 K and forms the second confinement barrier to tritium. The adiabatic vacuum is to reduce thermal loads applied to the superconducting coils and their supports so as to keep their temperature 4 K. The VVPS consists of a suppression tank located under the lower bio-shield and 4 relief pipes to connect the vacuum vessel and the suppression tank. The VVPS is to keep the maximum pressure rise of the vacuum vessel below the design value of 0.5 MPa in case of the in-vessel LOCA (water spillage from in-vessel component). The spilled water and steam are lead to the suppression tank through the relief pipes when the internal pressure of vacuum vessel is over 0.2 MPa, and then the internal pressure is kept below 0.5 MPa. This report summarizes the structural design of the cryostat main chamber and pressure suppression system, together with their fabrication and installation. (author)

  3. Energy Performance of a Novel System Combining Natural Ventilation with Diffuse Ceiling Inlet and Thermally Activated Building Systems (TABS)

    DEFF Research Database (Denmark)

    Yu, Tao

    As a response to new stringent energy policies in the building sector, office buildings have become well-insulated and highly-airtight, resulting in an increasing cooling need in both summer and winter. This study proposes a novel system combining natural ventilation with diffuse ceiling inlet...... and thermally activated building systems (TABS) for cooling and ventilation in future Danish office buildings. The new solution would have the special potential of using natural ventilation all year round even in the extremely cold seasons without any draught risk. The main focuses of this study are the energy...... saving potential and the steady-state and dynamic energy performance of this system. The presented work utilizes building simulation method to investigate the energy saving potential of this novel system. Afterwards, an experimental set-up is built in the laboratory to simulate a real office environment...

  4. Design and implementation of visual inspection system handed in tokamak flexible in-vessel robot

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hesheng; Xu, Lifei [Department of Automation, Shanghai Jiao Tong University, Shanghai 200240 (China); Key Laboratory of System Control and Information Processing, Ministry of Education of China (China); Chen, Weidong, E-mail: wdchen@sjtu.edu.cn [Department of Automation, Shanghai Jiao Tong University, Shanghai 200240 (China); Key Laboratory of System Control and Information Processing, Ministry of Education of China (China)

    2016-05-15

    In-vessel viewing system (IVVS) is a fundamental tool among the remote handling systems for ITER, which is used to providing information on the status of the in-vessel components. The basic functional requirement of in-vessel visual inspection system is to perform a fast intervention with adequate optical resolution. In this paper, we present the software and hardware solution, which is designed and implemented for tokamak in-vessel viewing system that installed on end-effector of flexible in-vessel robot working under vacuum and high temperature. The characteristic of our in-vessel viewing system consists of two parts: binocular heterogeneous vision inspection tool and first wall scene emersion based augment virtuality. The former protected with water-cooled shield is designed to satisfy the basic functional requirement of visual inspection system, which has the capacity of large field of view and high-resolution for detection precision. The latter, achieved by overlaying first wall tiles images onto virtual first wall scene model in 3D virtual reality simulation system, is designed for convenient, intuitive and realistic-looking visual inspection instead of viewing the status of first wall only by real-time monitoring or off-line images sequences. We present the modular division of system, each of them in smaller detail, and go through some of the design choices according to requirements of in-vessel visual inspection task.

  5. Aerial Remote Radio Frequency Identification System for Small Vessel Monitoring

    Science.gov (United States)

    2009-12-01

    Adventure vs. ecotourism —Environmental impact of so-called ecotourist activities—Brief Article. E: The Environmental Magazine. Retrieved December 18...2008, from http://www.dhs.gov/xlibrary/assets/small_vessel_NSVSS_Report_HQ_508.pdf Buckley, R. (2004). Environmental impacts of ecotourism . Cambridge

  6. Personal warning system for vessels under bad weather conditions

    NARCIS (Netherlands)

    Scholte, K.; Rothkrantz, L.J.M.

    2014-01-01

    Many services provide weather forecasts, including severe weather alerts for the marine. It proves that many ships neglect the warnings because they expect to be able to handle the bad weather conditions. In order to identify possible unsafe situations the Coast Guard needs to observe marine vessel

  7. Atherosclerosis of coronary blood vessels - local or systemic inflamation?

    Science.gov (United States)

    Pejkov, Hristo; Kedev, Sasko; Panov, Saso; Srbinovska-Kostovska, Elizabeta; Lang, Irene

    2013-01-01

    The presence of atherosclerotic lesions in the blood vessels is a predisposition for the development and occurrence of acute ischaemic attacks. Bigger atherosclerotic lesions in the coronary blood vessels cause lumen occlusion, which is a cause of acute myocardial infarction. Endothelial dysfunction is defined as an ability of the endothelium to produce vasorelaxing nitric oxide (NO), or deregulation of the other vasoactive substances, such as angiotensin II and endothelin [13]. This definition describes endothelial dysfunction as an improper vasomotor constriction of the vessel, that leads to lumen occlusion of the already existing atherosclerotic lesions. According to the modern model, the development of atherosclerotic plaque and inappropriate endothelial NO production have a synergistic role in patho-physiological and molecular processes in the blood vessels [14]. Lesions in the coronary arteries are deposits of huge quantities of foamy cells and fibrous plaques. The thin fibrous plaques are 10-20% of the total plaque population and are the cause of 80-90% of clinical cases due to their ability to rupture [48]. According to all the results from published studies by far, it has been pointed out that the plaque stability, not the absolute size influences the rupture potential. Elucidating the risk factors that may modify in the atherogenesis and the consequent atherothrombic effect is the first step to this goal.

  8. 47 CFR 80.383 - Vessel Traffic Services (VTS) system frequencies.

    Science.gov (United States)

    2010-10-01

    ... geographic radio protected areas. (a) Assigned frequencies: Vessel Traffic Control Frequencies Carrier frequencies (MHz) Geographic areas 156.250 Seattle. 156.550 New York, New Orleans, 2 Houston, Prince William... SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Frequencies Vessel Traffic Services System (vts...

  9. Natural ventilation systems to enhance sustainability in buildings: a review towards zero energy buildings in schools

    Directory of Open Access Journals (Sweden)

    Gil-Baez Maite

    2017-01-01

    Full Text Available European regulations set the condition of Zero Energy Buildings for new buildings since 2020, with an intermediate milestone in 2018 for public buildings, in order to control greenhouse gases emissions control and climate change mitigation. Given that main fraction of energy consumption in buildings operation is due to HVAC systems, advances in its design and operation conditions are required. One key element for energy demand control is passive design of buildings. On this purpose, different recent studies and publications analyse natural ventilation systems potential to provide indoor air quality and comfort conditions minimizing electric power consumption. In these passive systems are of special relevance their capacities as passive cooling systems as well as air renovation systems, especially in high-density occupied spaces. With adequate designs, in warm/mild climates natural ventilation systems can be used along the whole year, maintaining indoor air quality and comfort conditions with small support of other heating/cooling systems. In this paper is analysed the state of the art of natural ventilation systems applied to high density occupied spaces with special focus on school buildings. The paper shows the potential and applicability of these systems for energy savings and discusses main criteria for their adequate integration in school building designs.

  10. Natural ventilation systems to enhance sustainability in buildings: a review towards zero energy buildings in schools

    Science.gov (United States)

    Gil-Baez, Maite; Barrios-Padura, Ángela; Molina-Huelva, Marta; Chacartegui, Ricardo

    2017-11-01

    European regulations set the condition of Zero Energy Buildings for new buildings since 2020, with an intermediate milestone in 2018 for public buildings, in order to control greenhouse gases emissions control and climate change mitigation. Given that main fraction of energy consumption in buildings operation is due to HVAC systems, advances in its design and operation conditions are required. One key element for energy demand control is passive design of buildings. On this purpose, different recent studies and publications analyse natural ventilation systems potential to provide indoor air quality and comfort conditions minimizing electric power consumption. In these passive systems are of special relevance their capacities as passive cooling systems as well as air renovation systems, especially in high-density occupied spaces. With adequate designs, in warm/mild climates natural ventilation systems can be used along the whole year, maintaining indoor air quality and comfort conditions with small support of other heating/cooling systems. In this paper is analysed the state of the art of natural ventilation systems applied to high density occupied spaces with special focus on school buildings. The paper shows the potential and applicability of these systems for energy savings and discusses main criteria for their adequate integration in school building designs.

  11. Assessment of dynamic mechanical properties of the respiratory system during high-frequency oscillatory ventilation*.

    Science.gov (United States)

    Dellacà, Raffaele L; Zannin, Emanuela; Ventura, Maria L; Sancini, Giulio; Pedotti, Antonio; Tagliabue, Paolo; Miserocchi, Giuseppe

    2013-11-01

    1) To investigate the possibility of estimating respiratory system impedance (Zrs, forced oscillation technique) by using high-amplitude pressure oscillations delivered during high-frequency oscillatory ventilation; 2) to characterize the relationship between Zrs and continuous distending pressure during an increasing/decreasing continuous distending pressure trial; 3) to evaluate how the optimal continuous distending pressure identified by Zrs relates to the point of maximal curvature of the deflation limb of the quasi-static pressure-volume curve. Prospective laboratory animal investigation. Experimental medicine laboratory. Eight New Zealand rabbits. The rabbits were ventilated with high-frequency oscillatory ventilation. Zrs was measured while continuous distending pressure was increased and decreased between 2 and 26 cm H2O in 1-minute steps of 4 cm H2O. At each step, a low-amplitude (6 cm H2O) sinusoidal signal was alternated with a high-amplitude (18 cm H2O) asymmetric high-frequency oscillatory ventilation square pressure waveform. Pressure-volume curves were determined at the end of the continuous distending pressure trial. All measurements were repeated after bronchoalveolar lavage. Zrs was estimated from flow and pressure measured at the inlet of the tracheal tube and expressed as resistance (Rrs) and reactance (Xrs). Linear correlation between the values, measured by applying the small-amplitude sinusoidal signal and the ventilator waveform, was good for Xrs (r = 0.95 ± 0.04) but not for Rrs (r = 0.60 ± 0.34). Following lavage, the Xrs-continuous distending pressure curves presented a maximum on the deflation limb, identifying an optimal continuous distending pressure that was, on average, 1.1 ± 1.7 cm H2O below the point of maximal curvature of the deflation limb of the pressure-volume curves. Xrs can be accurately measured during high-frequency oscillatory ventilation without interrupting ventilation and/or connecting additional devices. An optimal

  12. Occupational exposure to nitrous oxide - the role of scavenging and ventilation systems in reducing the exposure level in operating rooms.

    Science.gov (United States)

    Krajewski, Wojciech; Kucharska, Malgorzata; Wesolowski, Wiktor; Stetkiewicz, Jan; Wronska-Nofer, Teresa

    2007-03-01

    The aim of this study was to assess the level of occupational exposure to nitrous oxide (N(2)O) in operating rooms (ORs), as related to different ventilation and scavenging systems used to remove waste anaesthetic gases from the work environment. The monitoring of N(2)O in the air covered 35 ORs in 10 hospitals equipped with different systems for ventilation and anaesthetic scavenging. The examined systems included: natural ventilation with supplementary fresh air provided by a pressure ventilation system (up to 6 air changes/h); pressure and exhaust ventilation systems equipped with ventilation units supplying fresh air to and discharging contaminated air outside the working area (more than 10 air changes/h); complete air-conditioning system with laminar air flow (more than 15 air changes/h). The measurements were carried out during surgical procedures (general anaesthesia induced intravenously and maintained with inhaled N(2)O and sevofluran delivered through cuffed endotracheal tubes) with connected or disconnected air scavenging. Air was collected from the breathing zone of operating personnel continuously through the whole time of anaesthesia to Tedlar((R)) bags, and N(2)O concentrations in air samples were analyzed by adsorption gas chromatography/mass spectrometry. N(2)O levels in excess of the occupational exposure limit (OEL) value of 180mg/m(3) were registered in all ORs equipped with ventilation systems alone. The OEL value was exceeded several times in rooms with natural ventilation plus supplementary pressure ventilations and twice or less in those with pressure/exhaust ventilation systems or air conditioning. N(2)O levels below or within the OEL value were observed in rooms where the system of air conditioning or pressure/exhaust ventilation was combined with scavenging systems. Systems combining natural/pressure ventilation with scavenging were inadequate to maintain N(2)O concentration below the OEL value. Air conditioning and an efficient pressure

  13. Airtightness and ventilation system performance of apartments in new multi-unit residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Cooke, G. [Air Solutions Inc., Toronto, ON (Canada); Kokko, J.; Greene, T. [Enermodal Engineering Ltd., Kitchener, ON (Canada)

    2005-07-01

    There are growing concerns that conventional air handling systems in apartment buildings cannot ventilate individual apartments, are expensive in terms of initial cost and maintenance, have little impact on indoor air quality, and negatively impact the integrity of fire and smoke control separations. This paper discusses the strategy of compartmentalizing individual apartments to eliminate uncontrolled air movement as well as providing efficient and effective ventilation in each suite. The findings of recent air leakage testing and ventilation system performance testing in several recently constructed high-rise buildings were documented in this paper. Results indicated that compartmentalization was a viable strategy. However, ventilation strategies for both common corridors and apartments required adjustments. Air leakage testing showed that individual apartments were relatively airtight. However, concerns were raised that continuous negative pressure could induce water leakage through the building envelope. Testing also discovered that airflow capacities of in-suite exhaust equipment was less than manufacturer's specifications. Duct lengths, diameters, fittings, elbows and termination details had an impact on airflow performance. Testing also confirmed that the corridor ventilation systems were not energy efficient as a significant amount of outdoor air was required to pressurize leaks in the corridors and to ensure sufficient air was available to make-up air requirements in each apartment in response to intermittent exhaust fan operation. It was also determined that a very small positive pressure was required to accomplish the task of pressurizing corridors to minimize odour transmission. The provision of weather-stripping on corridor to apartment doors would reduce the quantity of airflow required for pressurization, helping to prevent shifts in pressure due to opening doors, elevators and wind and stack pressures acting in varying ways. 8 refs., 4 tabs., 2

  14. Advanced Hybrid Spacesuit Concept Featuring Integrated Open Loop and Closed Loop Ventilation Systems

    Science.gov (United States)

    Daniel, Brian A.; Fitzpatrick, Garret R.; Gohmert, Dustin M.; Ybarra, Rick M.; Dub, Mark O.

    2013-01-01

    A document discusses the design and prototype of an advanced spacesuit concept that integrates the capability to function seamlessly with multiple ventilation system approaches. Traditionally, spacesuits are designed to operate both dependently and independently of a host vehicle environment control and life support system (ECLSS). Spacesuits that operate independent of vehicle-provided ECLSS services must do so with equipment selfcontained within or on the spacesuit. Suits that are dependent on vehicle-provided consumables must remain physically connected to and integrated with the vehicle to operate properly. This innovation is the design and prototype of a hybrid spacesuit approach that configures the spacesuit to seamlessly interface and integrate with either type of vehicular systems, while still maintaining the ability to function completely independent of the vehicle. An existing Advanced Crew Escape Suit (ACES) was utilized as the platform from which to develop the innovation. The ACES was retrofitted with selected components and one-off items to achieve the objective. The ventilation system concept was developed and prototyped/retrofitted to an existing ACES. Components were selected to provide suit connectors, hoses/umbilicals, internal breathing system ducting/ conduits, etc. The concept utilizes a lowpressure- drop, high-flow ventilation system that serves as a conduit from the vehicle supply into the suit, up through a neck seal, into the breathing helmet cavity, back down through the neck seal, out of the suit, and returned to the vehicle. The concept also utilizes a modified demand-based breathing system configured to function seamlessly with the low-pressure-drop closed-loop ventilation system.

  15. A Bayesian decision-support system for diagnosing ventilator-associated pneumonia

    OpenAIRE

    Schurink, C.A.; Visscher, S.; Lucas, P.J.; van Leeuwen, H.J.; Buskens, E.; Hoff, R.G.; Hoepelman, A.I.; Bonten, M.J.

    2007-01-01

    OBJECTIVE: To determine the diagnostic performance of a Bayesian Decision-Support System (BDSS) for ventilator-associated pneumonia (VAP). DESIGN: A previously developed BDSS, automatically obtaining patient data from patient information systems, provides likelihood predictions of VAP. In a prospectively studied cohort of 872 ICU patients, VAP was diagnosed by two infectious-disease specialists using a decision tree (reference diagnosis). After internal validation daily BDSS predictions were ...

  16. Alternative ventilation system for operating theaters: parameter study and full-scale assessment of the performance of a local ventilation system

    NARCIS (Netherlands)

    J.G.H. Loogman; Dr. H.S.M. Kort; I.M. de Visser; M.G.L.C. Loomans

    2016-01-01

    A local operating theater ventilation device to specifically ventilate the wound area has been developed and investigated. The ventilation device is combined with a blanket which lies over the patient during the operation. Two configurations were studied: Configuration 1 where HEPA-filtered air was

  17. A novel simulator for mechanical ventilation in newborns: MEchatronic REspiratory System SImulator for Neonatal Applications.

    Science.gov (United States)

    Baldoli, Ilaria; Cuttano, Armando; Scaramuzzo, Rosa T; Tognarelli, Selene; Ciantelli, Massimiliano; Cecchi, Francesca; Gentile, Marzia; Sigali, Emilio; Laschi, Cecilia; Ghirri, Paolo; Menciassi, Arianna; Dario, Paolo; Boldrini, Antonio

    2015-08-01

    Respiratory problems are among the main causes of mortality for preterm newborns with pulmonary diseases; mechanical ventilation provides standard care, but long-term complications are still largely reported. In this framework, continuous medical education is mandatory to correctly manage assistance devices. However, commercially available neonatal respiratory simulators are rarely suitable for representing anatomical and physiological conditions; a step toward high-fidelity simulation, therefore, is essential for nurses and neonatologists to acquire the practice needed without any risk. An innovative multi-compartmental infant respirator simulator based on a five-lobe model was developed to reproduce different physio-pathological conditions in infants and to simulate many different kinds of clinical scenarios. The work consisted of three phases: (1) a theoretical study and modeling phase, (2) a prototyping phase, and (3) testing of the simulation software during training courses. The neonatal pulmonary simulator produced allows the replication and evaluation of different mechanical ventilation modalities in infants suffering from many different kinds of respiratory physio-pathological conditions. In particular, the system provides variable compliances for each lobe in an independent manner and different resistance levels for the airway branches; moreover, it allows the trainer to simulate both autonomous and mechanically assisted respiratory cycles in newborns. The developed and tested simulator is a significant contribution to the field of medical simulation in neonatology, as it makes it possible to choose the best ventilation strategy and to perform fully aware management of ventilation parameters. © IMechE 2015.

  18. Comparison of indoor air distribution and thermal environment for different combinations of radiant heating systems with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2018-01-01

    air distribution and the thermal environment for all combinations of radiant heating systems with mechanical ventilation systems. Therefore, in this article, the indoor air distribution and the thermal environment were comparatively analyzed in a room with floor heating (FH) or ceiling heating (CH...

  19. Progressive loss of lymphatic vessels in skin of patients with systemic sclerosis.

    Science.gov (United States)

    Manetti, Mirko; Milia, Anna Franca; Guiducci, Serena; Romano, Eloisa; Matucci-Cerinic, Marco; Ibba-Manneschi, Lidia

    2011-02-01

    Systemic sclerosis (SSc) is a connective tissue disorder characterized by microvascular and fibrotic changes in the skin and internal organs. The role of blood vessel dysfunction in the pathogenesis of SSc has been extensively investigated, but few studies have addressed the involvement of the lymphatic vascular system. Our aim was to evaluate dermal lymphatic vessels in patients with SSc according to different phases of skin involvement. Skin biopsies were obtained from the forearm of 25 SSc patients (10 early/15 late-stage disease) and 13 healthy controls. Skin sections were immunostained for podoplanin (D2-40), which is selectively expressed in lymphatic endothelial cells, and examined by confocal laser scanning microscopy. Lymphatic vessels were counted in the papillary and reticular dermis. Data were analyzed using Student's t test. The number of lymphatic vessels was significantly reduced in the papillary and reticular dermis of SSc patients compared with controls. In early SSc, lymphatic vessel counts were not different from controls in the papillary dermis, and showed a trend toward a reduction in the reticular dermis. In late SSc, a significant reduction in lymphatic vessels compared with controls was found in both the papillary and reticular dermis. The number of lymphatic vessels in the papillary dermis of late SSc was significantly lower than in early SSc. In SSc, lymphatic microangiopathy is linked to the progression of skin involvement. The progressive disappearance of lymphatic vessels may have a critical pathogenetic role in the progression of SSc from an early edematous phase to overt fibrosis.

  20. Energy saving effect of desiccant ventilation system using Wakkanai siliceous shale

    Science.gov (United States)

    Nabeshima, Yuki; Togawa, Jun-ya; Nagano, Katsunori; Kazuyo, Tsuzuki

    2017-10-01

    The nuclear power station accident resulting from the Great East Japan Earthquake disaster has resulted in a constrained electricity supply. However, in this Asian region there is high temperature and high humidity and consequently dehumidification process requires a huge amount of energy. This is the reason for the increasing energy consumption in the residential and commercial sectors. Accordingly, a high efficiency air-conditioning system is needed to be developed. The desiccant ventilation system is effective to reduce energy consumption for the dehumidification process. This system is capable of dehumidifying without dew condensing unlike a conventional air-conditioning system. Then we focused on Wakkanai Siliceous Shale (WSS) as a desiccant material to develop a new desiccant ventilation system. This is low priced, high performance, new type of thing. The aim of this study is to develop a desiccant ventilation unit using the WSS rotor which can be regenerated with low-temperature by numerical calculation. The results of performance prediction of the desiccant unit, indicate that it is possible to regenerate the WSS rotor at low-temperature of between 35 - 45 °C. In addition, we produced an actual measurement for the desiccant unit and air-conditioning unit. This air-conditioning system was capable to reduce roughly 40 % of input energy consumption.

  1. Performance of a demand controlled mechanical extract ventilation system for dwellings

    Directory of Open Access Journals (Sweden)

    I. Pollet

    2013-10-01

    Full Text Available The main aim of ventilation is to guarantee a good indoor air quality, related to the energy consumed for heating and fan(s. Active or passive heat recovery systems seem to focus on the reduction of heating consumption at the expense of fan electricity consumption and maintenance. In this study, demandcontrolled mechanical extract ventilation systems of Renson (DCV1 and DCV2, based on natural supply in the habitable rooms and mechanical extraction in the wet rooms (or even the bedrooms, was analysed for one year by means of multi-zone Contam simulations on a reference detached house and compared with standard MEV and mechanical extract ventilation systems with heat recovery (MVHR. To this end, IAQ, total energy consumption, CO2 emissions and total cost of the systems are determined. The results show that DCV systems with increased supply air flow rates or direct mechanical extract from bedrooms can significantly improve IAQ, while reducing total energy consumption compared to MEV. Applying DCV reduces primary heating energy consumption and yearly fan electricity consumption at most by 65% to 50% compared to MEV. Total operational energy costs and CO2 emissions of DCV are similar when compared to MVHR. Total costs of DCV systems over 15 years are smaller when compared to MVHR due to lower investment and maintenance costs.

  2. Personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    The thermal environment and air quality in buildings affects occupants' health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard...... microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews...... existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice...

  3. Designing, Constructing and Installing a Local Exhaust Ventilation System to Minimize Welders\\' Exposure to Welding Fumes

    Directory of Open Access Journals (Sweden)

    Sajad Zare

    2017-10-01

    Full Text Available Background & Aims of the Study: Welder’s exposure to welding fumes can cause occupational diseases. The current study sought to examine exposure to welding fumes among welders who work in the repair shop of Sarcheshmeh Copper Complex and design a local exhaust ventilation system to control exposure to welding fumes. Materials & Methods: This applied analytical study was conducted in the summer of 2016 among welders working in the repair shop of Sarcheshmeh Copper Complex. The study comprised three phases; in the first one, welders’ exposure to welding fumes was assessed at the beginning of the study. After that, a local exhaust ventilation system was designed and installed in the aforementioned repair shop. In the final stage, welders’ exposure to welding fumes was assessed again after installation of the ventilation system. The procedure recommended by NIOSH (method number 7300 was used for individual sampling of welders. Results: Based on the obtained findings, before installing the ventilation system, welding technicians were exposed to 0.3 mg/m3 of copper fumes and 0.04 mg/m3 of chromium fumes. Journeyman welders were also exposed to 2.16 mg/m3 of manganese fumes, while stellar welders were exposed to 6.9 mg/m3 of iron fumes. In the light of these measurements, a local exhaust ventilation system was designed and installed. Subsequently, measurement of exposure to welding fumes showed a significant reduction. That is, welding technicians were exposed to 0.17 mg/m3 and 0.015 mg/m3 of copper and chromium fumes respectively. Additionally, journeyman welders were exposed to 0.86 mg/m3 of manganese fumes, whereas stellar welders were exposed to 4.3 mg/m3 of iron fumes. Conclusions: A comparison of standard limits of exposure to welding fumes and the results obtained from measurements in sampling stations before and after the installation of the local exhaust ventilation system reveals that this controlling measure was very effective in the

  4. Control System Implementation and Follow-up within the Cooling and Ventilation Contracts for the LHC

    CERN Document Server

    Body, Y; Morodo, M C

    2001-01-01

    The control system implementation for the cooling and ventilation facilities connected to the LHC Project relies on the technical and human resources that are organised within large-size industrial contracts. Beside the technical aspects, the follow-up of the implementation activities in the framework of such contracts also involves a managerial effort in order to achieve a flexible and coherent control system. The purpose is to assure precise and reliable regulation together with accurate local and remote supervision in conformity with the operational requirements. These objectives can only be reached by a systematic approach that keeps the co-ordination between the in-house and external cross-disciplinary teams as well as the fulfilment of the validation procedures and the contractual formalities. The case that here illustrates this approach is the control system implementation for the heating, ventilation and air conditioning of the LHC surface buildings, which shall extend up to 2004.

  5. An assessment of a partial pit ventilation system to reduce emission under slatted floor

    DEFF Research Database (Denmark)

    Wu, Wentao; Zhang, Guoqiang; Bjerg, Bjarne Schmidt

    2012-01-01

    CFD simulations were carried out to assess the feasibility of using RANS (Reynolds – averaged Navier– Stokes) turbulence models to evaluate the performance of a partial pit ventilation system to reduce gas emission under slatted floor. The entire system included a pit model with slatted floor...... and pit exhaust system, a wind table to simulate ground and a wind tunnel to simulate room space of a naturally ventilated livestock house. CFD simulations started with the selection of a proper domain. Two domains were chosen to evaluate the effect of domain simplification. The results showed...... mechanism of pollutant through slatted floor, vertical mean and turbulent flux were defined and calculated. It was found that turbulence diffusion dominates the transportation of pollutant from the pit headspace into the free stream. Although discrepancies existed for some conditions, good agreements...

  6. Active Fault Tolerant Control of Livestock Stable Ventilation System

    DEFF Research Database (Denmark)

    Gholami, Mehdi

    2011-01-01

    degraded performance even in the faulty case. In this thesis, we have designed such controllers for climate control systems for livestock buildings in three steps: Deriving a model for the climate control system of a pig-stable. Designing a active fault diagnosis (AFD) algorithm for different kinds......). In the FTC part of the thesis, first a passive fault tolerant controller (PFTC) based on state feed-back is proposed for discretetime PWA systems. only actuator faults are considered. By dissipativity theory and H1 analysis, the problem is cast as a set of linear matrix inequalities (LMIs). In the next...... contribution, the problem of reconfigurability of PWA systems is evaluated. A system subject to a fault is considered as reconfigurable if it can be stabilized by a state feedback controller and the optimal cost of the performance of the systems is admissible. In the previous methods the input constraints...

  7. On the thermal interaction of building structure and heating and ventilation system

    Science.gov (United States)

    Hensen, Joannes Laurentius Maria

    Developments in the field of building performance evaluation tools for thermal interaction of building structure and heating and ventilating systems are described. The technique employed is computer simulation of the integrated dynamic system comprising the occupants, the building and its heating and ventilating system. Assessment criteria from a literature review in thermal comfort to examine acceptable fluctuations in indoor climate are defined. Building and plant energy simulation within the context of Computer Aided Building Design (CABD) is described. An exisiting energy simulation environment ESP(R) (Environmental Systems Performance (Research version)) is chosen. A fluid flow network simulation module is described. Extensions to ESP(R) to predict the dynamic behavior of the heating and ventilation system are described. The coupling of fluid flow, plant side energy and mass, and building side energy simulation into one integrated program is described. A multistage verification and validation methodology is demonstrated by examples addressing each successive step. Imaginary and real world cases are described to demonstrate application of the study in a modeling orientated and a building engineering context.

  8. Performance potential of mechanical ventilation systems with minimized pressure loss

    DEFF Research Database (Denmark)

    Terkildsen, Søren; Svendsen, Svend

    2013-01-01

    simulations that quantify fan power consumption, heating demand and indoor environmental conditions. The system was designed with minimal pressure loss in the duct system and heat exchanger. Also, it uses state-of-the-art components such as electrostatic precipitators, diffuse ceiling inlets and demand...

  9. Draft report: application of organic Rankine cycle heat recovery systems to diesel powered marine vessels

    Energy Technology Data Exchange (ETDEWEB)

    1977-07-15

    The analysis and results of an investigation of the application of organic Rankine cycle heat recovery systems to diesel-powered marine vessels are described. The program under which this study was conducted was sponsored jointly by the US Energy Research and Development Administration, the US Navy, and the US Maritime Administration. The overall objective of this study was to investigate diesel bottoming energy recovery systems, currently under development by three US concerns, to determine the potential for application to marine diesel propulsion and auxiliary systems. The study primarily focused on identifying the most promising vessel applications (considering vessel type, size, population density, operational duty cycle, etc.) so the relative economic and fuel conservation merits of energy recovery systems could be determined and assessed. Vessels in the current fleet and the projected 1985 fleet rated at 1000 BHP class and above were investigated.

  10. Design and simulation of a hybrid ventilation system with earth-air heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Athienitis, A.K.; Zhao, M. [Concordia Univ., Centre for Building Studies, Montreal, PQ (Canada). Dept. of Building, Civil and Environmental Engineering; Roy, M. [Martin Roy and Associes Group Conseil Inc., Montreal, PQ (Canada)

    2005-07-01

    A simulation study was conducted during the design phase of a new circus building in Montreal which includes a hybrid ventilation system through which fresh air is supplied from an earth-air heat exchanger (EAHE). The EAHE has the potential to satisfy the cooling needs of the building and can also be used to preheat fresh air, thereby satisfying one-third or more of the building's heating needs. Another feature of the building is that it uses displacement ventilation by which the air is supplied at low velocities through large diffusers behind the top level seats or under the seats. In this study, computational fluid dynamics (CFD) simulations were carried out to help size the supply and return units of the heating, ventilating and air conditioning (HVAC) system, as well as the exhaust chimney. The primary objective of the CFD simulation was to determine the maximum velocity and temperature in the seated area to ensure thermal comfort. CFD simulation predictions were found to be in good agreement with preliminary measurements taken in the building. In order to monitor the operation of the system over the next year, the underground ducts were equipped with temperature sensors at several depths into the soil. The energy efficiency of the hybrid HVAC system will be assessed and the velocity and temperature distribution in the theatre will be examined under various operating and energy load conditions. 8 refs., 6 figs.

  11. Results of long-term field tests of protective earthing device for vessel electric systems

    Directory of Open Access Journals (Sweden)

    Blaginin V.A.

    2015-03-01

    Full Text Available The results of prolonged natural tests of protective neutral earthing device for controlling the fire and electrical safety of vessel electric systems have been shown. The use of such devices provides safe single-phase fault currents and reducing arc overvoltage during the long-term operation of a ship. The results of long-term monitoring of the device operation as part of the existing vessel electric power system have confirmed its effectiveness

  12. Cost optimization for buildings with hybrid ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Kun; Lu, Yan

    2018-02-13

    A method including: computing a total cost for a first zone in a building, wherein the total cost is equal to an actual energy cost of the first zone plus a thermal discomfort cost of the first zone; and heuristically optimizing the total cost to identify temperature setpoints for a mechanical heating/cooling system and a start time and an end time of the mechanical heating/cooling system, based on external weather data and occupancy data of the first zone.

  13. Ventilator Data Extraction with a Video Display Image Capture and Processing System.

    Science.gov (United States)

    Wax, David B; Hill, Bryan; Levin, Matthew A

    2017-06-01

    Medical hardware and software device interoperability standards are not uniform. The result of this lack of standardization is that information available on clinical devices may not be readily or freely available for import into other systems for research, decision support, or other purposes. We developed a novel system to import discrete data from an anesthesia machine ventilator by capturing images of the graphical display screen and using image processing to extract the data with off-the-shelf hardware and open-source software. We were able to successfully capture and verify live ventilator data from anesthesia machines in multiple operating rooms and store the discrete data in a relational database at a substantially lower cost than vendor-sourced solutions.

  14. EVALUATION OF BEST AVAILABLE CONTROL TECHNOLOGY FOR TOXICS -TBACT- DOUBLE SHELL TANK FARMS PRIMARY VENTILATION SYSTEMS SUPPORTING WASTE TRANSFER OPERATIONS

    Energy Technology Data Exchange (ETDEWEB)

    HAAS CC; KOVACH JL; KELLY SE; TURNER DA

    2010-06-24

    This report is an evaluation of Best Available Control Technology for Toxics (tBACT) for installation and operation of the Hanford double shell (DST) tank primary ventilation systems. The DST primary ventilation systems are being modified to support Hanford's waste retrieval, mixing, and delivery of single shell tank (SST) and DST waste through the DST storage system to the Waste Treatment and Immobilizaiton Plant (WTP).

  15. EVALUATION OF BEST AVAILABLE CONTROL TECHNOLOGY FOR TOXICS (TBACT) DOUBLE SHELL TANK FARMS PRIMARY VENTILATION SYSTEM SUPPORTING WASTE TRANSFER OPERATIONS

    Energy Technology Data Exchange (ETDEWEB)

    KELLY SE; HAASS CC; KOVACH JL; TURNER DA

    2010-06-03

    This report is an evaluation of Best Available Control Technology for Toxics (tBACT) for installation and operation of the Hanford double shell (DST) tank primary ventilation systems. The DST primary ventilation systems are being modified to support Hanford's waste retrieval, mixing, and delivery of single shell tank (SST) and DST waste throught the DST storage system to the Waste Treatment and Immobilization Plant (WTP).

  16. SIMULATION OF FREE CURRENT FLOWS IN BUOYANCY-DRIVEN VENTILATION SYSTEMS

    Directory of Open Access Journals (Sweden)

    D. V. Abramkina

    2017-01-01

    Full Text Available Objectives. The aim of the study is to analyse the effect of the design and methods for heating the ventilation duct of a buoyancy- driven system on the formation of free convective air currents in it.Methods. The study of free convection under the conditions of interior problem was carried out using the CFD software, based on  the finite volume method with unstructured grid. Ansys Fluent software was used as a calculation tool in the study, due to its having a high convergence of numerical solutions offering full-scale  measurements of convective currents.To evaluate the reliability of  the results obtained, a validation procedure was carried out, allowing us to determine how accurately the selected conceptual model describes the investigated flow through a comparison of experimental and numerical data.Results. The results of numerical modelling of free convective currents occurring in the heated channel of the ventilation system of  the top floor of a multi-storey residential building are presented in  the article. In the course of the study, the air velocity at the entrance to the ventilation duct was found to depend on the calculated  temperature difference θ ˚C for various heating methods. A gradual  increase in the discrepancy between the numerical simulation and  experimental results is observed if the calculated temperature  difference > 20 ° C. This phenomenon is due to the fact that with  increased duct temperature, it is quite difficult to achieve even  heating under actual conditions; this is especially noticeable when  considering the variant when the vertical part of the vent duct and the take-off are both heated. The maximum deviation of the  results is 4.4%. The obtained velocity profiles in the calculated  sections indicate the impact of the ventilation take-off on the nature  of the air flow motion.Conclusion. One of the drawbacks of the existing systems of natural ventilation of residential

  17. Assessment of buildings with ventilated facade systems and evaluation of point thermal bridges

    OpenAIRE

    Šadauskienė, Jolanta; Šeduikytė, Lina; Juozas RAMANAUSKAS; Buska, Andrius

    2017-01-01

    Analyzes of influence of the point thermal bridges of buildings with ventilated facade systems on the thermal properties of envelops are presented in the paper. The relation between the separate components of the envelop were made: thermal properties and thickness of supporting wall's layer; value of thermal conductivity and thickness of insulation layer. Studies have shown, that the value of the point thermal transmittance, which depended on the thermal properties of the envelop and thicknes...

  18. Plan of action for quality improvement of ventilation systems; Actieplan Kwaliteitsverbetering Ventilatievoorzieningen

    Energy Technology Data Exchange (ETDEWEB)

    Atsma, J. [Ministerie van Infrastructuur en Milieu IenM, Den Haag (Netherlands); Calon, M. [Aedes vereniging van woningcorporaties, Den Haag (Netherlands); Schoorl, F.J. [Bond Nederlandse Architecten BNA, Amsterdam (Netherlands); Van Tuinen, J.L. [Bouwend Nederland, Zoetermeer (Netherlands); Bodewes, W.J. [Vereniging van Nederlandse projectontwikkeling Maatschappijen Neprom, Voorburg (Netherlands); Goossens, J.H. [Vereniging voor ontwikkelaars en bouwondernemers NVB, Voorburg (Netherlands); Polman, E.J.M. [Stichting Waarborgfonds Koopwoningen SWK, Rotterdam (Netherlands); Engels, M. [Uneto-VNI, Zoetermeer (Netherlands); Werner-van Beek, H. J. [VACpunt Wonen, Utrecht (Netherlands); Mulder, R.J. [Vereniging Eigen Huis VEH, Amersfoort (Netherlands); Rook, G. [Vereniging Leveranciers van Luchttechnische Apparaten VLA, Zoetermeer (Netherlands); Van Noord, P. [Woningborg, Gouda (Netherlands); Paping, R.H.M. [De Nederlandse Woonbond, Amsterdam (Netherlands)

    2012-06-15

    The action plan comprises the agreements made by the Ministry of Infrastructure and Environment and the Ministry of Internal Affairs in the Netherlands with representatives of building organizations to improve the quality of ventilation systems in newly built houses [Dutch] Het actieplan bevat de afspraken die het ministerie van Infrastructuur en Milieu en het ministerie van Binnenlandse Zaken met de bouwpartijen hebben gemaakt om de kwaliteit van de ventilatievoorzieningen van nieuwbouwwoningen te verbeteren.

  19. State of Lipid Peroxidation and Antioxidant Defense System in Newborns Requiring Artificial Lung Ventilation

    OpenAIRE

    Kh.B. Slivinska-Kurchak; Yu.S. Korzhynsky; Ya.M. Mykytyn; O.M. Fitsala

    2013-01-01

    The article deals with studying indicators of lipid peroxidation (TBA-active products, lipid hydroperoxides, diene conjugates) and antioxidant defense (superoxide dismutase, glutathione peroxidase, vitamins A and E) in the blood of newborns on synchronized intermittent ventilation with pressure support and spontaneous breathing with continuous positive airway pressure via nasal cannula. The results show a more significant activation of lipid peroxidation system in newborns on synchronized int...

  20. Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-11-01

    The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

  1. Use of VOC sensors for air quality control of building ventilation systems

    OpenAIRE

    Großklos, M.

    2015-01-01

    Air quality control with VOC (volatile organic compound) sensors in residential buildings could increase user comfort by adapting to the actual contaminant level. Preliminary tests assessed the dynamics of VOC levels in single-family passive houses with a ventilation system. At normal and exceptional usages, sufficient signal variations were measured for air quality control. An air quality control was developed and tested in four single-family passive house dwellings to cont...

  2. Heating and cooling system for an on-board gas adsorbent storage vessel

    Energy Technology Data Exchange (ETDEWEB)

    Tamburello, David A.; Anton, Donald L.; Hardy, Bruce J.; Corgnale, Claudio

    2017-06-20

    In one aspect, a system for controlling the temperature within a gas adsorbent storage vessel of a vehicle may include an air conditioning system forming a continuous flow loop of heat exchange fluid that is cycled between a heated flow and a cooled flow. The system may also include at least one fluid by-pass line extending at least partially within the gas adsorbent storage vessel. The fluid by-pass line(s) may be configured to receive a by-pass flow including at least a portion of the heated flow or the cooled flow of the heat exchange fluid at one or more input locations and expel the by-pass flow back into the continuous flow loop at one or more output locations, wherein the by-pass flow is directed through the gas adsorbent storage vessel via the by-pass line(s) so as to adjust an internal temperature within the gas adsorbent storage vessel.

  3. A Novel In-Line Delivery System to Administer Dry Powder Mannitol to Mechanically Ventilated Patients.

    Science.gov (United States)

    Feng, Benny; Tang, Patricia; Leung, Sharon Shui Yee; Dhanani, Jayesh; Chan, Hak-Kim

    2017-04-01

    Mechanically ventilated patients commonly suffer from ventilator-associated pneumonia, hypoxemia, and other lower respiratory tract infection as a result of pathogen colonization and poor sputum clearance. Consequently, there is a high rate of morbidity and mortality in these patients. Dry powder mannitol increases sputum clearance, and therefore, we developed a system to administer it to mechanically ventilated patients without disconnection from the ventilator. The inspiratory line from a ventilator was split by using a three-way valve into two parallel lines where one contains a humidifier for normal breathing cycle and the other line contains a dry powder inhaler (Osmohaler™). The inspiratory air went through the dry powder line and aerosolized the mannitol powder only when its administration to a patient is required. We determined the delivered dose and particle size distributions of emitted aerosols in vitro from 9.5 mm endotracheal and 7.5 mm tracheostomy tubes, with inspiratory airflow of 60, 70, and 80 L/min. This novel setup was able to deliver 24.6% ± 3.33% of the 160 mg loaded dose mannitol powder (4 × 40 mg capsules) and 26.7% ± 2.19% of the 320 mg dose (4 × 80 mg capsules) when the endotracheal tube was used. With the shorter tracheostomy tube, the delivery dose increased to 35.6% ± 3.01% and 39.5% ± 2.04% of the 160 and 320 mg doses, respectively. The volume median diameters of the aerosols were in the respirable range with the largest value being 5.17 ± 0.87 μm. This delivery system has been shown to consistently deliver a high respirable dose of mannitol powder. Since this setup does not require disconnection of patients from the ventilator, it is safer for hypoxemic patients and easier to be adapted in a real clinical use.

  4. Flow change in a mine ventilation system with diagonal branch connections due to variations in aerodynamic resistances during transient regimes

    Energy Technology Data Exchange (ETDEWEB)

    Vuletic, V.

    1981-01-01

    The paper deals with investigations of parameters of ventilation systems affecting flow changes due to variations in the resistances in individual branches. The problem was studied on an analog computer.

  5. Correlation between germ and particle measurements for the qualification of ventilation systems in the OR

    Directory of Open Access Journals (Sweden)

    Bulitta Clemens

    2017-09-01

    Full Text Available Healthcare associated infections in surgical procedures have long been the focus of scientific research. In Germany, more than 225,000 patients suffer from such infections each year [1]. However, the reduction of the microbiological contamination is not only limited by cleaning and disinfecting measures. The choice of the ventilation system in the operating room or the type of the clothing of the personnel during the operation is also an important factor contributing to patient safety and infection control. Currently there are different approaches for assessing the hygienic situation in an operating room. In Germany, the air quality and cleanliness is evaluated by the DIN 1946-4: 2008-12 [2] and is based on the measurement of particles in the operating theatre. Other countries i.eSweden. focus on the biological contamination and use microbiological methods for the assessment and surveillance of the operating room ventilation (SIS-TS 39: 2015 [3].

  6. Dispersion of Exhalation Pollutants in a Two-bed Hospital Ward with a Downward Ventilation System

    DEFF Research Database (Denmark)

    Qian, Hua; Nielsen, Peter V.; Hyldgård, Carl-Erik

    2006-01-01

    The Centers for Disease Control and Prevention has recommended the use of downward ventilation systems in isolation rooms to reduce the risk of cross-infection from airborne transmissible diseases. The expected airflow pattern of a downward ventilation design would supply cooler and slightly...... heavier clean air from a ceiling diffuser to push down contaminants, which would then be removed via outlets at floor level. A "laminar" (strictly speaking, unidirectional) flow is expected to be produced to avoid flow mixing and thus reduce cross-infection risk. Experiments were carried out in a full...... to investigate the airflow pattern and pollutant dispersion in the test ward. Based on both experimental and numerical results, the laminar airflow pattern was shown to be impossible to achieve due to turbulent flow mixing and flow entrainment into the supply air stream. The thermal plumes produced above people...

  7. Effect of ventilation procedures on the behaviour of a fire compartment scenario

    Energy Technology Data Exchange (ETDEWEB)

    Pretrel, H. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Service d' Etude et de Recherches Experimentales sur les Accidents (SEREA), Laboratoire d' Experimentation des Feux -LEF, Centre de Cadarache, 13108 Cedex Saint Paul-lez-Durance (France)]. E-mail: hugues.pretrel@irsn.fr; Such, J.M. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Service d' Etude et de Recherches Experimentales sur les Accidents (SEREA), Laboratoire d' Experimentation des Feux - LEF, Centre de Cadarache, 13108 Cedex Saint Paul-lez-Durance (France)

    2005-09-01

    This contribution presents a study on the consequences of applying ventilation procedures during a fire scenario involving a TPH/TBP pool fire in a ventilated enclosure. This research is addressed to fire safety in the nuclear industry in which ventilated enclosures remain a configuration frequently encountered. This work presents experiments comprising a 300 kW liquid pool fire in a 400 m{sup 3} vessel connected to an industrial ventilation system featuring one inlet and one exhaust branch. The investigated ventilation procedures consist in closing the inlet branch only or closing both inlet and exhaust branches. The analysis compares fire behaviour with and without the implementation of a ventilation procedure and points out the effects of said procedures on the combustion rate, fire duration and gas temperature within the vessel. It highlights pressure variations within the vessel when both the inlet and exhaust ventilation branches are closed. Conclusions provide practical answers that would be useful when designing appropriate ventilation strategies limiting fire hazards.

  8. Numerical analysis of natural ventilation system in a studio apartment in Bangladesh

    Science.gov (United States)

    Kabir, K. M. Ariful; Hasan, Md. Rakibul; Khan, Md. Abdul Hakim

    2017-07-01

    The study of temperature and air flow for natural ventilation system has been investigated numerically. A finite element model for studio apartment was developed with the aim of achieving detail energy allocation in the real buildings during the transient process in the walls and internal air. A tool of computational fluid dynamics (CFD) is employed to assist the process. In the tropical regions most of the energy is consumed by the heating, cooling and ventilation appliances. Therefore, the optimize ventilation system will be a suitable and valid option for the saving of energy from the household sector to increase cooling performance and ensuring thermal comfort as well. A mathematical exploration is carried out on full scale dwelling and small scale model and indication is given on the relevance of such a comparison. Calculations are carried out with household heat sources for calm and windy period, but without any human. As expected, for windy periods, the wind is the main driving force behind the internal air flow. However, in calm periods for unsteady flow the internal airflow looks like more complexes through observation.

  9. Design Principles for Natural and Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation. ....... The hybrid ventilation concepts, design challenges and principles are discussed and illustrated by four building examples....

  10. Design Principles for Natural and Hybrid Ventilation

    OpenAIRE

    Heiselberg, Per

    2000-01-01

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation. The hybrid ventilation concepts, design challenges and principles are discussed and illustrated by four building examples.

  11. [A design of simple ventilator control system based on LabVIEW].

    Science.gov (United States)

    Pei, Baoqing; Xu, Shengwei; Li, Hui; Li, Deyu; Pei, Yidong; He, Haixing

    2011-01-01

    This paper designed a ventilator control system to control proportional valves and motors. It used LabVIEW to control the object mentioned above and design ,validate, evaluate arithmetic, and establish hardware in loop platform. There are two system' s hierarchies. The high layer was used to run non-real time program and the low layer was used to run real time program. The two layers communicated through TCP/IP net. The program can be divided into several modules, which can be expanded and maintained easily. And the harvest in the prototype designing can be seamlessly used to embedded products. From all above, this system was useful in employing OEM products.

  12. Physicochemical Characterization of Nanoparticles from Indoor Ventilation Systems and Their Potential Health Impacts

    Science.gov (United States)

    Dalton, G.; Revkin, A. C.; Gruenspecht, H.; Ramanathan, V.; Brown, M. A.; Nagel, D. C.; Revkin, A. C.; Umo, N. S.; Oseghe, E. O.

    2016-12-01

    Indoor air pollution remains a major concern to humans considering that we spend about 90% of our daily lives indoors [1,2]. Air pollutants, which ranges from gases to aerosol particles, vary considerably from our homes, public/work places and confined environments such as cars. They can impact on our health depending on the nature and concentration of the pollutants as well as the duration of exposure [3,4]. Particulate matter (PM), which is one of the major air pollutant markers, is present indoors and can be circulated for days to months within a confined space by the ventilation systems. In this study, both physical and chemical compositional evaluation of PM2.5 - 10 was carried out and the recirculation model of these particulates is presented based on the study of some ventilation systems such as air conditioners, cooling vents, and fans. For the first time, it is shown that the compositional variability of PM does not just depend on the source or the ongoing activities in the confined space but also on the recirculation time. Mineral dust particles were found to be dominant, some mixed with organics and soot or BC particles; heavy metals such as lead (Pb), cadmium (Cd), nickel (Ni), iron (Fe) and others were also analysed from the collected PM. Ventilation systems trap these particulates and do recirculate them over time and this can increase their toxicities and influences their composition. From this study, it can be suggested that regular cleaning of ventilation systems and flushing closed spaces with fresh air may become the most effective ways of controlling the concentration of PM in closed spaces with ventilation units such as indoors and cars. [1] H. K. Lai, et al., Atmospheric Environment 38 (37)(2004). [2] N.E. Klepeis, et al., J. of Exposure Analysis and Environmental Epidemiology 11(2001). [3] N. Bruce, et al., Bul. of the World Health Organization, 78 (9)(2000). [4] K.A. Miller, et al, The New England Journal of Medicine 356 (2007).

  13. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems

    DEFF Research Database (Denmark)

    Qian, H.; Li, Y.; Nielsen, Peter V.

    2006-01-01

    hospital ward with three ventilation systems, i.e. mixing, downward and displacement ventilation. Two life-size breathing thermal manikins were used to simulate a source patient and a receiving patient. The exhalation jet from a bed-lying manikin was visualized using smoke. N2O was used as tracer gas......Effective ventilation in general hospital wards is important for controlling the airborne transmission of infectious respiratory diseases. Experiments have been carried out to increase our understanding of the interaction of the breathing flows of two individuals in a full-scale experimental...

  14. Ventilator waveform interpretation in mechanically ventilated small animals.

    Science.gov (United States)

    Corona, Terry M; Aumann, Marcel

    2011-10-01

    To review the topic of ventilator waveforms analysis with emphasis on interpretation of ventilator waveforms and their use in the management and monitoring of mechanically ventilated small animal patients. Human clinical studies, scientific reviews, and textbooks, as well as veterinary textbooks and clinical examples of ventilator waveforms in mechanically ventilated dogs. Ventilator waveforms are graphic representations of data collected from the ventilator and reflect patient-ventilator interactions. The 4 parameters pressure, volume, flow, and time are most descriptive of mechanical ventilation. Typically, 3 different graphs, also referred to as scalars, consisting of pressure versus time, volume versus time, and flow versus time, with time always plotted on the x-axis, are used. Changes in the ventilator settings as well as in the characteristics of the lungs such as airway resistance (R(aw)) and respiratory system compliance (C(rs)) can be recognized from specific variations in the waveforms. Flow-volume and pressure-volume loops provide additional information about changes in lung function. Patient-ventilator dyssynchrony is a common problem during mechanical ventilation and can lead to patient discomfort and an increased work of breathing. Ventilator waveforms are helpful to identify dyssynchrony, which can be divided into trigger, flow, cycle, and expiratory dyssynchrony. Ventilator waveforms allow the clinician to assess changes in respiratory mechanics, and can be useful in monitoring the progression of disease pathology and response to therapy. Adjustments in ventilator settings based on proper analysis and interpretation of these waveforms can help the clinician to optimize ventilation therapy. Ventilator waveforms are graphic representations of patient-ventilator interactions. Proper interpretation of ventilator waveforms affords the critical care clinician a better understanding of the patient's respiratory function, response to therapy, and causes

  15. Numerical Study on Different Series Modes of Jet Fan in a Longitudinal Tunnel Ventilation System

    Directory of Open Access Journals (Sweden)

    Guihong Pei

    2014-01-01

    Full Text Available Efficient ventilation systems will contribute to maintaining air quality in the tunnel. In order to improve ventilation performance in normal traffic condition, the 3D tunnel models were established according to the original design for the tunnel located in central plains of China. Based on the commercial CFD software Fluent 6.3 and k-ε turbulence model, numerical simulations were carried out to study the patterns of jet flow and the optimization of fan combinations. It is found that the axial velocity profile obtained from numerical simulation agrees quite well with turbulent free jet theory although there is a little difference on the magnitude. The comparison of four combination modes under the condition of operating four fans indicates that the ventilation effectiveness is affected mainly by both the interval of adjacent groups of fans and the combination modes of operational fans. According to the simulation results, a novel combination mode which consists of a group double paralleled fans and two groups single fan is designed. The novel combination mode is regarded as the optimum combination mode with respect to maximizing air velocity in the tunnel. Compared to the traditional combination modes, it will increase the air velocity by 5.7%.

  16. State of Lipid Peroxidation and Antioxidant Defense System in Newborns Requiring Artificial Lung Ventilation

    Directory of Open Access Journals (Sweden)

    Kh.B. Slivinska-Kurchak

    2013-11-01

    Full Text Available The article deals with studying indicators of lipid peroxidation (TBA-active products, lipid hydroperoxides, diene conjugates and antioxidant defense (superoxide dismutase, glutathione peroxidase, vitamins A and E in the blood of newborns on synchronized intermittent ventilation with pressure support and spontaneous breathing with continuous positive airway pressure via nasal cannula. The results show a more significant activation of lipid peroxidation system in newborns on synchronized intermittent ventilation with pressure support. The level of TBA-active products, lipid hydroperoxides, diene conjugates in their blood is 1.4 times higher, than the corresponding rates in children on continuous positive airway pressure via nasal cannula. In addition to activation of lipid peroxidation we observed a decrease of antioxidant protection in newborns on synchronized intermittent ventilation with pressure support. The level of superoxide dismutase in erythrocytes was 1.3 times lower, glutathione peroxidase in erythrocytes — 1,7 times lower, the serum level of vitamin A — 2.8 times lower and the serum vitamin E — 2.2 times lower comparing with newborns on continuous positive airway pressure via nasal cannula.

  17. Online Design Aid for Evaluating Manure Pit Ventilation Systems to Reduce Entry Risk

    Directory of Open Access Journals (Sweden)

    Harvey B. Manbeck

    2016-05-01

    Full Text Available On-farm manure storage pits contain both toxic and asphyxiating gases such as hydrogen sulfide, carbon dioxide, methane and ammonia. Farmers and service personnel occasionally need to enter these pits to conduct repair and maintenance tasks. One intervention to reduce the toxic and asphyxiating gas exposure risk to farm workers when entering manure pits is manure pit ventilation. This article describes an online computational fluid dynamics based design aid for evaluating the effectiveness of manure pit ventilation systems to reduce the concentrations of toxic and asphyxiating gases in the manure pits. This design aid, developed by a team of agricultural engineering and agricultural safety specialists at Pennsylvania State University, represents the culmination of more than a decade of research and technology development effort. The article includes a summary of the research efforts leading to the online design aid development and describes protocols for using the online design aid, including procedures for data input and for accessing design aid results. Design aid results include gas concentration decay and oxygen replenishment curves inside the manure pit and inside the barns above the manure pits, as well as animated motion pictures of individual gas concentration decay and oxygen replenishment in selected horizontal and vertical cut plots in the manure pits and barns. These results allow the user to assess: (1 how long one needs to ventilate the pits to remove toxic and asphyxiating gases from the pit and barn, (2 from which portions of the barn and pit these gases are most and least readily evacuated, and (3 whether or not animals and personnel need to be removed from portions of the barn above the manure pit being ventilated.

  18. Personalized ventilation.

    Science.gov (United States)

    Melikov, A K

    2004-01-01

    The thermal environment and air quality in buildings affects occupants' health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard to physiological and psychological response, clothing insulation, activity, air temperature and air movement preference, etc. Environmental conditions acceptable for most occupants in rooms may be achieved by providing each occupant with the possibility to generate and control his/her own preferred microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice. Performance criteria are defined. Recommendations for design of PV that would be in compliance with the criteria are given. Future research needed on the topic is outlined. Personalized ventilation can improve occupants' comfort, decrease SBS symptoms and reduce the risk of transmission of contagion between occupants in comparison with total volume ventilation. However in order to perform efficiently in rooms in practice, the design (air distribution, control, etc.) has to be carefully considered together with type of occupant activity (occupancy rate, occupied density, etc.).

  19. Contribution to the study of hybrid ventilation system effectiveness in office and educational buildings; Contribution a l'etude de l'efficacite des systemes de ventilation hybride dans les batiments du secteur tertiaire

    Energy Technology Data Exchange (ETDEWEB)

    Cron, F.

    2004-06-15

    This study is part of the International Energy Agency Annex 35, 'Hybrid Ventilation in New and Retro-fitted Office Buildings', also called the HybVent Project. It presents the numerical analyses of a number of hybrid ventilation systems and their potential for several buildings in relation to local climate characteristics. The first part of this work reviews the state-of-the-art of existing ventilation systems and details the principles, expectations and features of hybrid ventilation systems. This first section also examines some examples of hybrid systems extracted from the collection of Annex 35 case studies. A comprehensive bibliography of numerical tools available for this type of analysis is given in the second section. The numerical models for building simulation and the object-oriented environment used to develop our simulation tool are presented in this section as well. Two single-zone studies undertaken in this project are reported in the third section. The first study concerns an experimental cell simulation. Numerical results are compared to experimental data to validate the use of the simulation tool developed. The second single-zone study predicts the potential of a specific hybrid ventilation system in a typical classroom, given climatic conditions. Finally, the last section presents a more complete study - a multi-zone study of the Tonga school, an Annex 35 case study located in Sweden. Three rooms were modelled initially to compare numerical results to experimental data and then to analyse the performance of the existing hybrid ventilation system and two other systems. This final study was completed for three European cities with very different climates. The overall analysis of the potential of the hybrid ventilation systems considered and the perspective for future work are outlined in the conclusion. (author)

  20. Experimental research on the indoor temperature and humidity fields in radiant ceiling air-conditioning system under natural ventilation

    Science.gov (United States)

    Huang, Tao; Xiang, Yutong; Wang, Yonghong

    2017-05-01

    In this paper, the indoor temperature and humidity fields of the air in a metal ceiling radiant panel air conditioning system with fresh air under natural ventilation were researched. The temperature and humidity distributions at different height and different position were compared. Through the computation analysis of partial pressure of water vapor, the self-recovery characteristics of humidity after the natural ventilation was discussed.

  1. Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients.

    Science.gov (United States)

    Palomero-Rodríguez, Miguel Angel; de Arteaga, Héctor Chozas; Báez, Yolanda Laporta; de Vicente Sánchez, Jesús; Carretero, Pascual Sanabria; Conde, Pilar Sánchez; Pérez Ferrer, Antonio

    2016-01-01

    Over the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants ("Mapleson D CPAP system"). The primary goal of this study was to assess the usefulness of the "Mapleson D CPAP system" for weaning of mechanical ventilation (MV) in infants who received MV over 24 h. All infants who received MV for more than 24 h in the last year were enrolled in the study. Demographic data included age, gender, weight, and admission diagnosis. Heart rate, respiratory rate, blood pressure, and oxygen saturation were measured during MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation. Patients were classified into two groups: patients MV more than 48 h, and patients with MV fewer than 48 h. P Mapleson D CPAP system and 2 h after extubation and spontaneous ventilation with the nasopharyngeal Mapleson D CPAP system or with nasal prongs. The overall extubation failure rate was 26% (n = 13). Weight and age were significantly associated with extubation failure (P Mapleson D CPAP system, in our opinion, is a useful and safe alternative to more complex and expensive noninvasive CPAP and BiPAP weaning from MV in infants.

  2. Experimental Study of Air Vessel Behavior for Energy Storage or System Protection in Water Hammer Events

    Directory of Open Access Journals (Sweden)

    Mohsen Besharat

    2017-01-01

    Full Text Available An experimental assessment of an air pocket (AP, confined in a compressed air vessel (CAV, has been investigated under several different water hammer (WH events to better define the use of protection devices or compressed air energy storage (CAES systems. This research focuses on the size of an AP within an air vessel and tries to describe how it affects important parameters of the system, i.e., the pressure in the pipe, stored pressure, flow velocity, displaced volume of water and water level in the CAV. Results present a specific range of air pockets based on a dimensionless parameter extractable for other real systems.

  3. Evaluation of local exhaust ventilation system performance for control of Fe2O3 dust at an iron making unit

    Directory of Open Access Journals (Sweden)

    Mahdi Jamshidi Rastani

    2016-06-01

    Full Text Available Introduction: Adherence to the design values and ventilation standards (VS after installing and also maintaining continuous work of ventilation system with maximum performance throughout its life are amongst the reasons of ventilation systems monitoring. Therefore, the aim of this study was to evaluate performance of local exhaust ventilation system for control of dust by measuring the operating parameters and also to compare it with ventilation standards (VS and design values. Material and Method: The present research is a descriptive and cross-sectional study, conducted in three sections of measuring, monitoring and evaluating the operating parameters on hoods, channels and fan of ventilation system based on the current status of the system, documentation (design, and recommended standards (VS. Static pressure, velocity pressure, surface area, and flow rate were measured based on the recommendations of various sources and ACGIH industrial ventilation manual, and the data were compared with the design and recommended values, using the SPSS software version 16.   Result: The results of paired sample t-test between flow rate and velocities of design and current status, showed significant differences in various parts. Accordingly, the results revealed a reduction of more than 50% in the design duct velocity compared to the current duct velocity, while design duct velocity is 1.3 more than the standard duct velocity of current status, and current duct velocity is about 65% of standard duct velocity. Conclusion: The reduction and nonconformity of the results of measurements of operating parameters (after a minimum of two decades with design and standard values are corroborant and sufficient reason for obstructions, abrasions, leaks, imbalance of system ducts and their inefficiency in some branches. Since there is no base line measurements for system (supposing that the system worked with maximum amounts of setup time, one of the reasons for these

  4. Neuroradiologic Characteristics of Primary Angiitis of the Central Nervous System According to the Affected Vessel Size.

    Science.gov (United States)

    Thaler, Christian; Kaufmann-Bühler, Ann-Katrin; Gansukh, Tserenchunt; Gansukh, Amarjargal; Schuster, Simon; Bachmann, Henrike; Thomalla, Götz; Magnus, Tim; Matschke, Jakob; Fiehler, Jens; Siemonsen, Susanne

    2017-09-05

    Magnetic resonance imaging (MRI) has an important impact in diagnosing primary angiitis of the central nervous system (PACNS). However, neuroradiologic findings may vary immensely, making an easy and definite diagnosis challenging. In this retrospective, single center study, we analyzed neuroradiologic findings of patients with PACNS diagnosed at our hospital between 2009 and 2014. Furthermore, we classified patients according to the affected vessel size and compared imaging characteristics between the subgroups. Thirty-three patients were included (mean age 43 [±15.3] years, 17 females) in this study. Patients with positive angiographic findings were classified as either medium or large vessel PACNS and presented more ischemic lesions (p < 0.001) and vessel wall enhancement (p = 0.017) compared to patients with small vessel PACNS. No significant differences were detected for the distribution of contrast-enhancing lesions (parenchymal or leptomeningeal), hemorrhages, or lesions with mass effect. Twenty-five patients underwent brain biopsy. Patients with medium or large vessel PACNS were less likely to have positive biopsy results. It is essential to differentiate between small and medium/large vessel PACNS since results in MRI, digital subtraction angiography and brain biopsy may differ immensely. Since image quality of MR scanners improves gradually and brain biopsy may often be nonspecific or negative, our results emphasize the importance of MRI/MRA in the diagnosis process of PACNS.

  5. Individually ventilated cages impose cold stress on laboratory mice: a source of systemic experimental variability.

    Science.gov (United States)

    David, John M; Knowles, Scott; Lamkin, Donald M; Stout, David B

    2013-11-01

    Individual ventilated cages (IVC) are increasing in popularity. Although mice avoid IVC in preference testing, they show no aversion when provided additional nesting material or the cage is not ventilated. Given the high ventilation rate in IVC, we developed 3 hypotheses: that mice housed in IVC experience more cold stress than do mice housed in static cages; that IVC-induced cold stress affects the results of experiments using mice; and that, when provided shelters, mice behaviorally thermoregulate and thereby rescue the cold-stress effects of IVC. To test these hypotheses, we housed mice in IVC, IVC with shelters, and static cages maintained at 20 to 21 °C. We quantified the cold stress of each housing system on mice by assessing nonshivering thermogenesis and brown adipose vacuolation. To test housing effects in a common, murine model of human disease, we implanted mice with subcutaneous epidermoid carcinoma cells and quantified tumor growth, tumor metabolism, and adrenal weight. Mice housed in IVC had histologic signs of cold stress and significantly higher nonshivering thermogenesis, smaller subcutaneous tumors, lower tumor metabolism, and larger adrenal weights than did mice in static cages. Shelters rescued IVC-induced nonshivering thermogenesis, adrenal enlargement, and phenotype-dependent cold-mediated histologic changes in brown adipose tissue and tumor size. IVC impose chronic cold stress on mice, alter experimental results, and are a source of systemic confounders throughout rodent-dependent research. Allowing mice to exhibit behavioral thermoregulation through seeking shelter markedly rescues the experiment-altering effects of housing-imposed cold stress, improves physiologic uniformity, and increases experimental reproducibility across housing systems.

  6. A Dual Vessel System of Phosphating Ferrous Alloys under Steam Pressure

    Science.gov (United States)

    1979-08-01

    2. Manganese phosphate 5. Pressure process 3. Heat resistance 20. ABSTRACT fConfftiue MX r...success of pressure phosphating using consecutive produc- tion-type runs in the dual vessel system. For this manganese tartrate bath, 30% of the...recycling system is recommended for utilization of this process in the application of heavy manganese phosphate coatings to ferrous metal items. (U

  7. 46 CFR 25.45-2 - Cooking systems on vessels carrying passengers for hire.

    Science.gov (United States)

    2010-10-01

    ... stated therein, and liquefied petroleum gas (LPG), or compressed natural gas (CNG). (b) Cooking systems... the appliance. The valve must be located between the fuel tank and the point where the fuel supply... for hire. (a) No fuel may be used in any cooking system on any vessel carrying passengers for hire...

  8. Applications and Energy Consumption of Demand Controlled Ventilation Systems. Modelling, Simulation and Implementation of Modular Built Dynamical VAV Systems and Control Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Bjoern R.

    2002-07-01

    This thesis discusses many topics of heating and ventilation. This is because the ventilation system is an integrated part of its host building. The functionality and effectiveness of the ventilation system are very much dependent on the building's architectural design, its internal materials, its occupants, its air tightness characteristics and its placement in the terrain. Although this thesis emphasizes strongly on VAV (Variable Air Volume) systems and, in particular, modelling and simulation of such systems, it touches a range of important HVAC related issues. The scope is however, limited to the field of comfort ventilation. That is because ventilation in industrial environments often is subject to separate regulations, and requires other and specialized methods of design and evaluation of ventilation performance. The main objectives have been to: (1) Develop mathematical models for VAV components and systems. (2) Evaluate existing and develop new strategies for VAV demand controlled ventilation by system simulation. (3) Investigate the potential for saving energy and the impact on indoor climate. The development of mathematical models and simulation of VAV systems are given quite much attention compared to the other topics discussed.

  9. Heat pipes as perspective base elements of heat recovery in heat supply and ventilating systems

    Directory of Open Access Journals (Sweden)

    Matveev Andrey

    2017-01-01

    Full Text Available Thermotechnical characteristics of heat pipes are considered as high-efficient heat-transfer devices, which can provide energy-saving technologies for heat supply and ventilating systems and for different branches of industry. Thermotechnical and working (”performance capability” characteristics of heat pipes are investigated. By ”performance capability” of heat pipes and heat-transfer devices on heat pipes we mean the system state, where it can perform set functions and keep parameter values (thermal power, conductivity, thermal resistance, heat-transfer coefficient, temperature level and differential, etc. within the regulations of standardized specifications. The article presents theoretical and experimental methods of «gaslock» length determination on noncondensable gases during long-lasting tests of ammonia heat pipes made of aluminum shape АS – КRА 7.5 – R1 (alloy АD – 31. The paper gives results of research of thermotechnical characteristics of heat pipes in horizontal and vertical states (separate and as a set part while using different systems of thermal insulation. The obtained results of thermotechnical and resource tests show the advantages of ammonia heat pipes as basic elements for heat exchanger design in heating and ventilation systems.

  10. A method for evaluating the problem complex of choosing the ventilation system for a new building

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2007-01-01

    for evaluating the performance of a ventilation system in the design proces by treating quantifiable and non-quantifiable datasets together. The method is based on general morphological analysis and applies cross-consistency assessment for reducing the problem complex, thus treating the multi......-dimensionality, the uncertainty and the subjectivity that arises in the design proces on a sound methodological and scientific basis. Through a distance analysis of the shared parameter values the solution scenarios may be plotted relative to each other, hence providing the designer with an illustrated ‘space of solutions...

  11. Closed system cell culture protocol using HYPERStack vessels with gas permeable material technology.

    Science.gov (United States)

    Titus, Kim; Klimovich, Vitaly; Rothenberg, Mark; Pardo, Pilar; Tanner, Allison; Martin, Greg

    2010-11-29

    Large volume adherent cell culture is currently standardized on stacked plate cell growth products when microcarrier beads are not an optimal choice. HYPERStack vessels allow closed system scale up from the current stacked plate products and delivers >2.5X more cells in the same volumetric footprint. The HYPERStack vessels function via gas permeable material which allows gas exchange to occur, therefore eliminating the need for internal headspace within a vessel. The elimination of headspace allows the compartment where cell growth occurs to be minimized to reduce space, allowing more layers of cell growth surface area within the same volumetric footprint. For many applications such as cell therapy or vaccine production, a closed system is required for cell growth and harvesting. The HYPERStack vessel allows cell and reagent addition and removal via tubing from media bags or other methods. This protocol will explain the technology behind the gas permeable material used in the HYPERStack vessels, gas diffusion results to meet the metabolic needs of cells, closed system cell growth protocols, and various harvesting methods.

  12. Composite Overwrapped Pressure Vessels (COPV) Monitoring System Using Fiber Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Intelligent Fiber Optic Systems Corporation (IFOS) proposes, in this Phase 1 SBIR project, to demonstrate the feasibility of innovations based on an...

  13. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan

    2017-01-01

    A novel system combining diffuse ceiling ventilation and radiant ceiling was proposed recently, with the aim of providing energy efficient and comfort environment to office buildings. Designing of such a system is challenging because of complex interactions between the two subsystems and a large...... model was further applied to evaluate the effects of different design parameters, including the U-value of the diffuse ceiling panel, plenum height, plenum depth, and inlet configuration. In the integrated system, diffuse ceiling separated the radiant ceiling from the rest of the room and consequently...... changed the energy efficiency of the radiant system. The simulated results demonstrated that using ceiling panel with a higher U-value can minimize this impact and make the system to cool down space efficiently. Low plenum height was beneficial to the energy efficiency, but aggravated the non...

  14. Electro-mechanical connection system for ITER in-vessel magnetic sensors

    Energy Technology Data Exchange (ETDEWEB)

    Rizzolo, Andrea; Brombin, Matteo; Gonzalez, Winder [Consorzio RFX, Corso Stati Uniti, 4, 35127 Padova (Italy); Marconato, Nicolò, E-mail: nicolo.marconato@igi.cnr.it [Consorzio RFX, Corso Stati Uniti, 4, 35127 Padova (Italy); Peruzzo, Simone [Consorzio RFX, Corso Stati Uniti, 4, 35127 Padova (Italy); Arshad, Shakeib [Fusion for Energy, C/Josep Pla, 2, 08019 Barcelona (Spain); Ma, Yunxing; Vayakis, George [ITER Organization, Route de Vinon-sur-Verdon, 13067 St Paul Lez Durance (France); Williams, Adrian [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon, Oxon, OX14 1RL (United Kingdom)

    2016-11-01

    Highlights: • Latest status of the ITER “Generic In-Vessel Magnetic Platform” design activity. • Integration within the ITER In-Vessel configuration model. • Geometry optimization based on thermo-mechanical and magnetic field 3D calculation. • Assessment of the remote handling maintenance compatibility. - Abstract: This paper presents the preliminary design of the “In-Vessel Magnetic platform”, which is a subsystem of the magnetic diagnostics formed by all the components necessary for guaranteeing the thermo-mechanical interface of the actual magnetic sensors with the vacuum vessel (VV), their protection and the electrical connection to the in-vessel wiring for the transmission of the detected signal with a minimum level of noise. The design has been developed in order to comply with different functional requirements: the mechanical attachment to the VV; the electrical connection to the in-vessel wiring; efficient heat transfer to the VV; the compatibility with Remote Handling (RH) system for replacement; the integration of metrology features for post-installation control; the Electro Magnetic Interference (EMI) shielding from Electron Cyclotron Heating (ECH) stray radiation without compromising the sensor pass band (15 kHz). Significant effort has been dedicated to develop the CAD model, integrated within the ITER In-Vessel configuration model, taking care of the geometrical compliance with the Blanket modules (modified in order to accommodate the magnetic sensors in suitable grooves) and the RH compatibility. Thorough thermo-mechanical and electro-magnetic Finite Element Method (FEM) analyses have been performed to assess the reliability of the system in standard and off-normal operating conditions for the low frequency magnetic sensors.

  15. A novel adaptive control system for noisy pressure-controlled ventilation: a numerical simulation and bench test study.

    Science.gov (United States)

    Beda, Alessandro; Spieth, Peter M; Handzsuj, Thomas; Pelosi, Paolo; Carvalho, Nadja C; Koch, Edmund; Koch, Thea; Gama de Abreu, Marcelo

    2010-01-01

    There is growing interest in the use of both variable and pressure-controlled ventilation (PCV). The combination of these approaches as "noisy PCV" requires adaptation of the mechanical ventilator to the respiratory system mechanics. Thus, we developed and evaluated a new control system based on the least-mean-squares adaptive approach, which automatically and continuously adjusts the driving pressure during PCV to achieve the desired variability pattern of tidal volume (V (T)). The controller was tested during numerical simulations and with a physical model reproducing the mechanical properties of the respiratory system. We applied step changes in respiratory system mechanics and mechanical ventilation settings. The time needed to converge to the desired V (T) variability pattern after each change (t (c)) and the difference in minute ventilation between the measured and target pattern of V (T) (DeltaMV) were determined. During numerical simulations, the control system for noisy PCV achieved the desired variable V (T) pattern in less than 30 respiratory cycles, with limited influence of the dynamic elastance (E*) on t (c), except when E* was underestimated by >25%. We also found that, during tests in the physical model, the control system converged in mechanical ventilation in the intensive care unit.

  16. Flow requirements and rebreathing during mechanically controlled ventilation in a T-piece (Mapleson E) system.

    Science.gov (United States)

    Hatch, D J; Yates, A P; Lindahl, S G

    1987-12-01

    The influence of fresh gas flow (FGF) setting on rebreathing was investigated in 15 infants and children (weight 3.5-21.8 kg) during balanced anaesthesia with mechanically controlled ventilation using a T-piece (Mapleson E) system and a Nuffield ventilator 200. Tidal volume (VT), minute volume (VE), maximal inspired (PICO2) and end-tidal (PE'CO2) carbon dioxide tensions and airway pressure were measured. VE, set to produce a PE'CO2 of about 4.5 kPa and measured at a high FGF (minimal rebreathing), was unchanged throughout the study and the regression equation for VE and weight was: VE (ml min-1) = 146 x kg + 482, r = 0.92. Measurements were then repeated at FGF:VE ratios reduced to 1.5 and 1.0. To achieve minimal rebreathing (PICO2 less than 0.5 kPa), FGF:VE ratios greater than 1.8 (range 1.8-4.9) had to be used. At FGF:VE ratios of 1.5, some alveolar rebreathing occurred, indicated by increased inspired (P less than 0.001) and end-tidal (P less than 0.001) carbon dioxide tensions. At FGF:VE ratios equal to 1.0, alveolar rebreathing was more pronounced and hypercapnoea occurred with a PE'CO2 (mean +/- 1 SD) of 5.89 +/- 0.53 kPa. At this FGF setting, change in I:E ratio from 1:2 to 1:1 did not influence the level of alveolar rebreathing. A minimal FGF (ml min-1) setting of 1.5 x VE (that is, 1.5 (146 x kg + 482), approximated to the expression (200 x kg + 1000) is recommended for controlled ventilation to avoid hypercapnoea when using the T-piece system in children weighing less than 20 kg.

  17. Modifications of tissular oxygenation and systemic hemodynamics after the correction of hypocapnia induced by mechanical ventilation.

    Science.gov (United States)

    Boix, J H; Marin, J; Enrique, E; Monferrer, J; Bataller, A; Servera, E

    1994-03-01

    The modifications of systemic hemodynamics, oxygen transport and tissular oxygenation in mechanically-ventilated critical ARF (acute respiratory failure) patients, after the correction of its hypocapnia by addition of dead space (VD) are determined. The prospective and randomized study was carried out in a multidisciplinary ICU. Fifteen ARF patients were studied within the first 48 hours of evolution. All the patients were intubated and mechanically ventilated. Three stages were delimited: I) 30 min after the beginning of anesthesia; II) 30 min after adding 30 cm of VD; III) 30 min after replacing the previous VD with a VD of 60 cm. Similar steady states had been reached when the measurements were taken. Ventilation parameters and FiO2 were kept stable. In stage I the patients presented a pure respiratory alkalosis and, with respect to hemodynamics, a hyperdynamic situation. In stage II the acid-base balance was normalized with a continuation of the hyperdynamic situation and an increase in mixed venous oxygen tension and saturation (PvO2 and SvO2) (p < 0.001). Stage III was characterized by a pure hypercapnic acidosis and an increase in capillary wedge pressure (CWP) (p < 0.05), right atrial pressure (RAP) (p < 0.001) and cardiac output (Qt) (p < 0.001); simultaneously, the systemic vascular resistances (SVR) decreased (p < 0.01), the PvO2, SvO2 and oxygen delivery (DO2) increased (p < 0.001); oxygen utilization coefficient (OUC) decreased (p < 0.01). The results suggest that the variations in PvO2 and SvO2 are a direct consequence of the modifications in blood flow.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Displacement ventilation

    DEFF Research Database (Denmark)

    Kosonen, Risto; Melikov, Arsen Krikor; Mundt, Elisabeth

    The aim of this Guidebook is to give the state-of-the art knowledge of the displacement ventilation technology, and to simplify and improve the practical design procedure. The Guidebook discusses methods of total volume ventilation by mixing ventilation and displacement ventilation and it gives...... insights of the performance of the displacement ventilation. It also shows practical case studies in some typical applications and the latest research findings to create good local micro-climatic conditions....

  19. Problems with combined fresh air - off-air systems. Ventilation systems; Probleme bei kombinierten Zu- und Abluftgeraeten. Lueftungstechnische Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    Lexis, J.

    2003-12-01

    As a rule, specifications on air volumes are made for ventilation systems for fresh air supply only or, alternatively, off-air removal only. In case of mixed air or recirculation, the required air volumes may differ considerably from the specifications. [German] In der Regel beziehen sich die Ausschreibungs- bzw. Garantieluftmengen auf den Betrieb einer lueftungstechnischen Anlage mit reiner Aussen- und Fortluft. Bei Umluft- oder Mischluftbetrieb koennen die geforderten Luftmengen jedoch erheblich von den Ausschreibungsforderungen abweichen. (orig.)

  20. Exploration Mission Particulate Matter Filtration Technology Performance Testing in a Simulated Spacecraft Cabin Ventilation System

    Science.gov (United States)

    Agui, Juan H.; Vijayakumar, R.; Perry, Jay L.; Frederick, Kenneth R.; Mccormick, Robert M.

    2017-01-01

    Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.

  1. Natural Ventilation in Atria

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Heiselberg, Per; Hendriksen, Ole Juhl

    This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions.......This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions....

  2. Analysis and Choice of Optimal Heating Ventilation Air Conditioning System for a Teaching Unit

    Directory of Open Access Journals (Sweden)

    Marina Verdeş

    2007-01-01

    Full Text Available Under the conditions of present society in which providing an optimum interior comfort is confronted with the necessity of the energy consumption reduction, solving this problem depends on the factors which contribute to the achievements of this comfort. Modern buildings -- implicitly teaching unit -- may be equipped with installations which have low energy consumption, respective a heating, cooling and ventilating integrated system with heat pumps system which can assure all the required comfort conditions. This paper underlines the necessity to use the heat pump in heating system for a teaching unit, energetic and economic guides and the possibility to increase them when using cooling and heating mixed. The solution of heat pumps for heating of the teaching unit and the energetic and economic advantages of the system is made in study.

  3. ASSESSMENT of POTENTIAL CARBON DIOXIDE-BASED DEMAND CONTROL VENTILATION SYSTEM PERFORMANCE in SINGLE ZONE SYSTEMS

    Science.gov (United States)

    2013-03-21

    8  Figure 3. Summer Philadelphia Office Space Indoor CO2 Concentration (Rackes and...Calculated Outdoor air Ventilation Rate (Jeong et al., 2010) .......................... 26  Figure 8. Calculated Zone CO2 Concentration (Jeong et al., 2010...29 Figure 11. Resulting CO2 Concentration in Different DCV Implementation

  4. IDENTIFICATION SYSTEM, TRACKING AND SUPPORT FOR VESSELS ON RIVERS

    Directory of Open Access Journals (Sweden)

    SAMOILESCU Gheorghe

    2015-05-01

    Full Text Available According to the program COMPRIS (Consortium Operational Management Platform River Information Services, AIS (Automatic Identification System, RIS (River Information Services have compiled a reference model based on the perspective of navigation on the river with related information services. This paper presents a tracking and monitoring surveillance system necessary for assistance of each ship sailing in an area of interest. It shows the operating principle of the composition and role of each equipment. Transferring data to traffic monitoring authority is part of this work.

  5. A computerized decision support system to predict the variations in the cerebral blood flow of mechanically ventilated infants.

    Science.gov (United States)

    Tehrani, Fleur T

    2013-10-01

    A computerized decision support system is described to predict the changes in the cerebral blood flow (CBF) of mechanically ventilated infants in response to different ventilatory settings. A CBF controller was developed and combined with a mathematical model of the infant's respiratory system to simulate the effects of ventilatory settings on the infant's CBF. The performance of the system was examined under various ventilatory treatments and the results were compared with available experimental data. The comparisons showed good agreement between the simulation results and experimental data for preterm infants. These included the results obtained under conditions of hypoventilation, hyperventilation, hypoxia, and hyperoxia. The presented decision support system has the potential to be used as an aide to the intensivist in choosing appropriate ventilation treatments for infants to prevent the untoward consequences of hazardous changes in CBF in mechanically ventilated infants such as hypoxic-ischemic brain injuries. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Integrated data acquisition system for coastal research vessel

    Digital Repository Service at National Institute of Oceanography (India)

    Desai, R.G.P.; Desa, E.

    transportability. The data is logged on a central file server based on a Novell Netware operating system with fault tolerant features. Remote node communication allows easy access to data from shore-based LAN. The network supports microcontroller interface to log...

  7. Complications of mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Drašković Biljana

    2011-01-01

    Full Text Available Mechanical ventilation of the lungs, as an important therapeutic measure, cannot be avoided in critically ill patients. However, when machines take over some of vital functions there is always a risk of complications and accidents. Complications associated with mechanical ventilation can be divided into: 1 airway-associated complications; 2 complications in the response of patients to mechanical ventilation; and 3 complications related to the patient’s response to the device for mechanical ventilation. Complications of artificial airway may be related to intubation and extubation or the endotracheal tube. Complications of mechanical ventilation, which arise because of the patient’s response to mechanical ventilation, may primarily cause significant side effects to the lungs. During the last two decades it was concluded that mechanical ventilation can worsen or cause acute lung injury. Mechanical ventilation may increase the alveolar/capillary permeability by overdistension of the lungs (volutrauma, it can exacerbate lung damage due to the recruitment/derecruitment of collapsed alveoli (atelectrauma and may cause subtle damages due to the activation of inflammatory processes (biotrauma. Complications caused by mechanical ventilation, beside those involving the lungs, can also have significant effects on other organs and organic systems, and can be a significant factor contributing to the increase of morbidity and mortality in critically ill of mechanically ventilated patients. Complications are fortunately rare and do not occur in every patient, but due to their seriousness and severity they require extensive knowledge, experience and responsibility by health-care workers.

  8. Double Shell Tank (DST) Ventilation System Vapor Sampling and Analysis Plan

    Energy Technology Data Exchange (ETDEWEB)

    SASAKI, L.M.

    2000-06-08

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples from the primary ventilation systems of the AN, AP, AW, and AY/AZ tank farms. Sampling will be performed in accordance with Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Air DQO) (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications. Vapor samples will be obtained from tank farm ventilation systems, downstream from the tanks and upstream of any filtration. Samples taken in support of the DQO will consist of SUMMA{trademark} canisters, triple sorbent traps (TSTs), sorbent tube trains (STTs), polyurethane foam (PUF) samples. Particulate filter samples and tritium traps will be taken for radiation screening to allow the release of the samples for analysis. The following sections provide the general methodology and procedures to be used in the preparation, retrieval, transport, analysis, and reporting of results from the vapor samples.

  9. CFD Simulation and Optimisation of a Low Energy Ventilation and Cooling System

    Directory of Open Access Journals (Sweden)

    John Kaiser Calautit

    2015-04-01

    Full Text Available Mechanical Heating Ventilation and Air-Conditioning (HVAC systems account for 60% of the total energy consumption of buildings. As a sector, buildings contributes about 40% of the total global energy demand. By using passive technology coupled with natural ventilation from wind towers, significant amounts of energy can be saved, reducing the emissions of greenhouse gases. In this study, the development of Computational Fluid Dynamics (CFD analysis in aiding the development of wind towers was explored. Initial concepts of simple wind tower mechanics to detailed design of wind towers which integrate modifications specifically to improve the efficiency of wind towers were detailed. From this, using CFD analysis, heat transfer devices were integrated into a wind tower to provide cooling for incoming air, thus negating the reliance on mechanical HVAC systems. A commercial CFD code Fluent was used in this study to simulate the airflow inside the wind tower model with the heat transfer devices. Scaled wind tunnel testing was used to validate the computational model. The airflow supply velocity was measured and compared with the numerical results and good correlation was observed. Additionally, the spacing between the heat transfer devices was varied to optimise the performance. The technology presented here is subject to a patent application (PCT/GB2014/052263.

  10. Multifamily Ventilation Retrofit Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Lstiburek, J.; Bergey, D.

    2012-12-01

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  11. Influence of paravertebral miorelaxant on arbitrary maximal ventilation of respirators system at skilled sportsmen

    Directory of Open Access Journals (Sweden)

    Syshko D.V.

    2012-09-01

    Full Text Available The functional being of the respirator system of the skilled sportsmen, engaged in the greco-roman fight (n=22, heavy athletics (n=25 and football (n=24 before and after course of paravertebral miorelaxant, is studied. The course of paravertebral miorelaxant was the system of exercises in a water environment with the use of «noodle». The necessity of application of correction influences, for sportsmen, was conditioned by the presence of hypertonic of paravertebral muscles, registered through miotonometric. It is got, those parameters of arbitrary maximal ventilation of respirators system (MVR, after the course of paravertebral miorelaxant, changed depending on the orientation of the training process determined by the type of sport. It is certain, whatever the change of tone of paravertebral muscles renders the reliable changes in the structure of arbitrary MVL at footballers, for certain affects chronotropics to the component at heavy athletics and inotropics at the representatives of the greco-roman fight.

  12. OPAL - extension for use with ventilation and pump systems; OPAL-Erweiterung mit Luefter- und Pumpensystemen

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, R.

    2003-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) discusses how an existing software tool called OPAL that supports the energy-efficient dimensioning of electrical drive systems was extended to cover pump and fan applications. According to the authors, the new version 3 allows the energy efficiency of such systems as well as the economic feasibility of many types of improvement projects to be evaluated in a fast and accurate manner. Software is described that has been designed and optimised using real world examples that can be often found in the water supply and facility management areas. These include heating-system pumps as well as ventilation and pressure-boosting applications. The practicability and benefits offered by the tool are demonstrated using several examples.

  13. K West Basin Integrated Water Treatment System (IWTS) E-F Annular Filter Vessel Accident Calculations

    Energy Technology Data Exchange (ETDEWEB)

    PIEPHO, M.G.

    2000-01-10

    Four bounding accidents postulated for the K West Basin integrated water treatment system are evaluated against applicable risk evaluation guidelines. The accidents are a spray leak during fuel retrieval, spray leak during backflushing a hydrogen explosion, and a fire breaching filter vessel and enclosure. Event trees and accident probabilities are estimated. In all cases, the unmitigated dose consequences are below the risk evaluation guidelines.

  14. Thermal-Hydraulic Assessment of W7-X Plasma Vessel Venting System in Case of 40 mm In-Vessel LOCA

    Directory of Open Access Journals (Sweden)

    E. Urbonavičius

    2015-01-01

    Full Text Available This paper presents assessment of the capacity of W7-X venting system in response to in-vessel LOCA, rupture of 40 mm diameter pipe during operation mode “baking.” The integral analysis of the coolant release from the cooling system, pressurisation of PV, and response of the venting system is performed using RELAP5 code. The same coolant release rate was introduced to the COCOSYS code, which is a lumped-parameter code developed for analysis of processes in containment of the light water reactors and the detailed analysis of the plasma vessel and the venting system is performed. Different options of coolant release modeling available in COCOSYS are compared to define the base case model, which is further used for assessment of the other parameters, that is, the failure of one burst disk, the temperature in the environment, and the pressure losses in the piping of venting system. The performed analysis identified the best option for coolant release modeling and showed that the capacity of the W7-X venting system is enough to prevent overpressure of the plasma vessel in the case of in-vessel LOCA.

  15. Performance Analysis of Multipurpose Refrigeration System (MRS on Fishing Vessel

    Directory of Open Access Journals (Sweden)

    Ust Y.

    2016-04-01

    Full Text Available The use of efficient refrigerator/freezers helps considerably to reduce the amount of the emitted greenhouse gas. A two-circuit refrigerator-freezer cycle (RF reveals a higher energy saving potential than a conventional cycle with a single loop of serial evaporators, owing to pressure drop in each evaporator during refrigeration operation and low compression ratio. Therefore, several industrial applications and fish storage systems have been utilized by using multipurpose refrigeration cycle. That is why a theoretical performance analysis based on the exergetic performance coefficient, coefficient of performance (COP, exergy efficiency and exergy destruction ratio criteria, has been carried out for a multipurpose refrigeration system by using different refrigerants in serial and parallel operation conditions. The exergetic performance coefficient criterion is defined as the ratio of exergy output to the total exergy destruction rate (or loss rate of availability. According to the results of the study, the refrigerant R32 shows the best performance in terms of exergetic performance coefficient, COP, exergy efficiency, and exergy destruction ratio from among the other refrigerants (R1234yf, R1234ze, R404A, R407C, R410A, R143A and R502. The effects of the condenser, freezer-evaporator and refrigerator-evaporator temperatures on the exergetic performance coefficient, COP, exergy efficiency and exergy destruction ratios have been fully analyzed for the refrigerant R32.

  16. Assessment of the Economic and Environmental Impact of Double Glazed Façade Ventilation Systems in Mediterranean Climates

    Directory of Open Access Journals (Sweden)

    Pere Alavedra

    2013-09-01

    Full Text Available Free convection is the most often used method in order to reduce solar load gains on a building with double glazed façades (DGFs. However, depending on the climate factors, the thermal performance of a DGF may not be satisfactory and extra energy costs are required to obtain suitable comfort conditions inside the building. Forced ventilation systems are a feasible alternative to improve the thermal performance of a DGF in Mediterranean climates where large solar gains are a permanent condition throughout the year. In this paper the feasibility of using diverse forced ventilation methods in DGF is evaluated. In addition, an economical comparison between different mechanical ventilation systems was performed in order to demonstrate the viability of DGF forced ventilation. Moreover, an environmental study was carried out to prove the positive energetic balance on cooling loads between free and forced convection in DGF for Mediterranean climates. For this investigation, a CFD model was used to simulate the thermal conditions in a DGF for the different ventilation systems. Results obtained for heat flux, temperature and reductions in solar load gains were analyzed and applied for the economic and environmental research.

  17. Experimental analysis of fuzzy controlled energy efficient demand controlled ventilation economizer cycle variable air volume air conditioning system

    Directory of Open Access Journals (Sweden)

    Rajagopalan Parameshwaran

    2008-01-01

    Full Text Available In the quest for energy conservative building design, there is now a great opportunity for a flexible and sophisticated air conditioning system capable of addressing better thermal comfort, indoor air quality, and energy efficiency, that are strongly desired. The variable refrigerant volume air conditioning system provides considerable energy savings, cost effectiveness and reduced space requirements. Applications of intelligent control like fuzzy logic controller, especially adapted to variable air volume air conditioning systems, have drawn more interest in recent years than classical control systems. An experimental analysis was performed to investigate the inherent operational characteristics of the combined variable refrigerant volume and variable air volume air conditioning systems under fixed ventilation, demand controlled ventilation, and combined demand controlled ventilation and economizer cycle techniques for two seasonal conditions. The test results of the variable refrigerant volume and variable air volume air conditioning system for each techniques are presented. The test results infer that the system controlled by fuzzy logic methodology and operated under the CO2 based mechanical ventilation scheme, effectively yields 37% and 56% per day of average energy-saving in summer and winter conditions, respectively. Based on the experimental results, the fuzzy based combined system can be considered to be an alternative energy efficient air conditioning scheme, having significant energy-saving potential compared to the conventional constant air volume air conditioning system.

  18. A study of energy use for ventilation and air-conditioning systems in Hong Kong

    Science.gov (United States)

    Yu, Chung Hoi Philip

    Most of the local modern buildings are high-rise with enclosed structure. Mechanical ventilation and air conditioning (MVAC) systems are installed for thermal comfort. Various types of MVAC systems found in Hong Kong were critically reviewed with comments on their characteristics in energy efficiency as well as application. The major design considerations were also discussed. Besides MVAC, other energy-consuming components in commercial buildings were also identified, such as lighting, lifts and escalators, office equipment, information technology facilities, etc. A practical approach has been adopted throughout this study in order that the end results will have pragmatic value to the heating, ventilating and air-conditioning (HVAC) industry in Hong Kong. Indoor Air Quality (IAQ) has become a major issue in commercial buildings worldwide including Hong Kong. Ventilation rate is no doubt a critical element in the design of HVAC systems, which can be realized more obviously in railway train compartments where the carbon dioxide level will be built up quickly when the compartments are crowded during rush hours. A study was carried out based on a simplified model using a train compartment that is equipped with an MVAC system. Overall Thermal Transfer Value (OTTV) is a single-value parameter for controlling building energy use and is relatively simple to implement legislatively. The local government has taken a first step in reacting to the worldwide concern of energy conservation and environmental protection since 1995. Different methods of OTTV calculation were studied and the computation results were compared. It gives a clear picture of the advantages and limitations for each method to the building designers. However, due to the limitations of using OTTV as the only parameter for building energy control, some new approaches to a total control of building energy use were discussed and they might be considered for future revision of the building energy codes in Hong

  19. The role of ventilation and HVAC systems for human health in nonindustrial indoor environments. A supplementary review by EUROVEN group

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Sundell, Jan; Bischof, W.

    2002-01-01

    with increased productivity, and that air-conditioning systems may increase the risk of sick building syndrome (SBS) symptoms. Taking these findings into account, the group has elaborated 35 hypotheses on the role of ventilation ahd HVAC systems in nonindustrial indoor environments with regard to human health...

  20. Dependence of flow variations on changes in aerodynamic resistances in underground mine ventilation systems with line-parallel branch connections

    Energy Technology Data Exchange (ETDEWEB)

    Vuletic, V.

    1980-01-01

    The parameters of ventilation systems which affect the interdependence of flow variations and changes of resistance in individual branches of the system are discussed. The investigation was carried out by simulation on an analogue computer. (11 refs.) (In Serbo-Croat)

  1. Experimental study including subjective evaluations of mixing and displacement ventilation combined with radiant floor heating/cooling system

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2013-01-01

    heating or by a combination of radiant floor heating and mixing ventilation system. The vertical air temperature distribution was more uniform for floor heating. The discomfort due to cold feet/lower legs was higher for warm air heating, but no significant difference in thermal perceptions between the two...... lower floor temperature, warmer supply air, and less homogeneous vertical temperature profile, but it did not result in thermal discomfort on feet/lower legs or discomfort due to a vertical air temperature difference higher than for a displacement ventilation system alone, where the floor temperature...

  2. Effect of a ceiling fan ventilation system on finishing young bulls' health, behaviour and growth performance.

    Science.gov (United States)

    Magrin, L; Brscic, M; Lora, I; Rumor, C; Tondello, L; Cozzi, G; Gottardo, F

    2017-06-01

    This research aimed at assessing the effects of a ceiling fan ventilation system on health, feeding, social behaviour and growth response of finishing young bulls fattened indoors during a mild summer season. A total of 69 Charolais young bulls were housed in six pens without any mechanical ventilation system (Control) and in six pens equipped with ceiling fans. The experimental period lasted 98 days from June until mid-September 2014. Four experimental days were considered in order to assess the effect of the ventilation system under two different microclimatic conditions: 2 alert days at monthly interval with temperature humidity index (THI) between 75 and 78, and 2 normal days with THI⩽74. Health and behaviour of the bulls were evaluated through 8-h observation sessions starting after morning feed delivery. The study was carried out during a rather cool summer with a climate average THI of 68.9 and 4 days with average THI>75. Despite these mild climate conditions, ceiling fans lowered litter moisture and acted as a preventive measure for bulls' dirtiness (odd ratio=47.9; 95% CI 19.6 to 117.4). The risk of abnormal breathing was increased for Control bulls (odd ratio=40.7; 95% CI 5.4 to 304.2). When exposed to alert THI conditions, respiration rate and panting scores increased and rumination duration dropped in Control bulls compared with bulls provided with a ceiling fan. During observations under alert THI, bulls spent less time eating, more time being inactive and consumed more water compared with normal THI conditions. Bulls' daily dry matter intake measured during the observation sessions decreased on alert compared with normal THI days (PCeiling fan treatment had no effect on bulls' growth performance or water consumption but these results most likely depended on the mild climate conditions. Ceiling fans proved to mitigate some of the negative effects of heat stress on bulls' behaviour (rumination, lying down and drinking water) and respiration rate

  3. Analysis and optimization on in-vessel inspection robotic system for EAST

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Weijun, E-mail: zhangweijun@sjtu.edu.cn; Zhou, Zeyu; Yuan, Jianjun; Du, Liang; Mao, Ziming

    2015-12-15

    Since China has successfully built her first Experimental Advanced Superconducting TOKAMAK (EAST) several years ago, great interest and demand have been increasing in robotic in-vessel inspection/operation systems, by which an observation of in-vessel physical phenomenon, collection of visual information, 3D mapping and localization, even maintenance are to be possible. However, it has been raising many challenges to implement a practical and robust robotic system, due to a lot of complex constraints and expectations, e.g., high remanent working temperature (100 °C) and vacuum (10{sup −3} pa) environment even in the rest interval between plasma discharge experiments, close-up and precise inspection, operation efficiency, besides a general kinematic requirement of D shape irregular vessel. In this paper we propose an upgraded robotic system with redundant degrees of freedom (DOF) manipulator combined with a binocular vision system at the tip and a virtual reality system. A comprehensive comparison and discussion are given on the necessity and main function of the binocular vision system, path planning for inspection, fast localization, inspection efficiency and success rate in time, optimization of kinematic configuration, and the possibility of underactuated mechanism. A detailed design, implementation, and experiments of the binocular vision system together with the recent development progress of the whole robotic system are reported in the later part of the paper, while, future work and expectation are described in the end.

  4. Analysis of hybrid interface cooling system using air ventilation and nanofluid

    Science.gov (United States)

    Rani, M. F. H.; Razlan, Z. M.; Bakar, S. A.; Desa, H.; Wan, W. K.; Ibrahim, I.; Kamarrudin, N. S.; Bin-Abdun, Nazih A.

    2017-09-01

    The hybrid interface cooling system needs to be designed for maintaining the electric vehicle's battery cell temperature at 25°C. The hybrid interface cooling system is a combination of two individual systems, where the primary cooling system (R-134a) and the secondary cooling system (CuO + Water) will be used to absorb the heat generated by the battery cells. The ventilation system is designed using air as the medium to transfer the heat from the batteries to the refrigeration system (R-134a). Research will focus on determining the suitable compressor displacement, the heat exchanger volume and the expansion valve resistance value. The analysis for the secondary cooling system is focused on the cooling coil where low temperature nanofluid is passing through each interval of the battery cells. For analysing purposes, the thermal properties of the mixture of 50 grams, Copper (II) Oxide and the base fluid have been determined. The hybrid interface cooling system are able to achieve 57.82% increments in term of rate of heat transfer as compared to the individual refrigeration system.

  5. Fungal colonization of air filters for use in heating, ventilating, and air conditioning (HVAC) systems.

    Science.gov (United States)

    Simmons, R B; Crow, S A

    1995-01-01

    New and used cellulosic air filters for HVAC systems including those treated with antimicrobials were suspended in vessels with a range of relative humidities (55-99%) and containing non-sterile potting soil which stimulates fungal growth. Most filters yielded fungi prior to suspension in the chambers but only two of 14 nontreated filters demonstrated fungal colonization following use in HVAC systems. Filters treated with antimicrobials, particularly a phosphated amine complex, demonstrated markedly less fungal colonization than nontreated filters. In comparison with nontreated cellulosic filters, fungal colonization of antimicrobial-treated cellulosic filters was selective and delayed.

  6. Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients

    Directory of Open Access Journals (Sweden)

    Miguel Angel Palomero-Rodríguez

    2016-01-01

    Full Text Available Background: Over the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants (“Mapleson D CPAP system”. The primary goal of this study was to assess the usefulness of the “Mapleson D CPAP system” for weaning of mechanical ventilation (MV in infants who received MV over 24 h. Materials and Methods: All infants who received MV for more than 24 h in the last year were enrolled in the study. Demographic data included age, gender, weight, and admission diagnosis. Heart rate, respiratory rate, blood pressure, and oxygen saturation were measured during MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation. Patients were classified into two groups: patients MV more than 48 h, and patients with MV fewer than 48 h. P < 0.05 was considered statistically significant. Results: A total of 50 children were enrolled in the study, with a median age was 34 ± 45 months (range, 1-59 months and median weight was 11.98 ± 9.31 kg (range, 1-48 kg. Median duration of MV was 480 h (range, 2-570. There were no significant differences in PaO 2 , PaCO 2 , and pH among MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation and spontaneous ventilation with the nasopharyngeal Mapleson D CPAP system or with nasal prongs. The overall extubation failure rate was 26% (n = 13. Weight and age were significantly associated with extubation failure (P < 0.05. Conclusions: The Mapleson D CPAP system, in our opinion, is a useful and safe alternative to more complex and expensive noninvasive CPAP and BiPAP weaning from MV in infants.

  7. Subjective Evaluation of the Microenvironment Generated by a Hospital Bed with Localized Ventilation System

    DEFF Research Database (Denmark)

    Kehayova, Nushka; Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor

    2016-01-01

    A novel method for local hospital bed ventilation, called HBIVCU (Hospital Bed with Integrated Ventilation and Cleansing Unit), was studied in a human subject experiment. The goal of this study was to identify human response to the microenvironment generated by a hospital bed with installed HBIVCU...... and to compare with human response to the micro-environment at a hospital bed without local ventilation. 32 participants took part in two experimental conditions - hospital bed with and without installed HBIVCU. Subject’s votes on the bed microenvironment were collected via standardized questionnaires....... The subjects evaluated the perceived air quality in the ventilated bed as better compared to that in the non-ventilated bed. The whole body thermal sensation (WTS) and acceptability votes were decreasing over time for the non-ventilated bed condition. Significant differences in the local thermal sensation LTS...

  8. Evaluation of a Shaker Dust Collector for Use in a Recirculating Ventilation System.

    Science.gov (United States)

    Peters, Thomas M; Sawvel, Russell A; Park, Jae Hong; Anthony, T Renée

    2015-01-01

    General ventilation with recirculated air may be cost-effective to control the concentration of low-toxicity, contaminants in workplaces with diffuse, dusty operations, such as in agriculture. Such systems are, however, rarely adopted with little evidence showing improved air quality and ability to operate under harsh conditions. The goal of this work was to examine the initial and long-term performance of a fabric-filter shaker dust collector (SDC) in laboratory tests and as deployed within a recirculating ventilation system in an agricultural building. In laboratory tests, collection efficiency and pressure drop were tracked over several filter loading cycles, and the recovery of filter capacity (pressure drop) from filter shaking was examined. Collection efficiencies of particles larger than 5 μm was high (>95%) even when the filter was pristine, showing effective collection of large particles that dominate inhalable concentrations typical of agricultural dusts. For respirable-sized particles, collection efficiencies were low when the filter was pristine (e.g., 27% for 1 μm) but much higher when a dust cake developed on the filter (>99% for all size particles), even after shaking (e.g., 90% for 1 μm). The first shake of a filter was observed to recovery a substantial fraction of filter capacity, with subsequent shakes providing little benefit. In field tests, the SDC performed effectively over a period of three months in winter when incorporated in a recirculating ventilation system of a swine farrowing room. Trends in collection efficiency and pressure drop with loading were similar to those observed in the laboratory with overall collection efficiencies high (>80%) when pressure drop exceeded 230 Pa, or 23% of the maximum loading recommended by the manufacturer. This work shows that the SDC can function effectively over the harsh winter in swine rearing operations. Together with findings of improved air quality in the farrowing room reported in a

  9. Completing fishing monitoring with spaceborne Vessel Detection System (VDS) and Automatic Identification System (AIS) to assess illegal fishing in Indonesia.

    Science.gov (United States)

    Longépé, Nicolas; Hajduch, Guillaume; Ardianto, Romy; Joux, Romain de; Nhunfat, Béatrice; Marzuki, Marza I; Fablet, Ronan; Hermawan, Indra; Germain, Olivier; Subki, Berny A; Farhan, Riza; Muttaqin, Ahmad Deni; Gaspar, Philippe

    2017-10-26

    The Indonesian fisheries management system is now equipped with the state-of-the-art technologies to deter and combat Illegal, Unreported and Unregulated (IUU) fishing. Since October 2014, non-cooperative fishing vessels can be detected from spaceborne Vessel Detection System (VDS) based on high resolution radar imagery, which directly benefits to coordinated patrol vessels in operation context. This study attempts to monitor the amount of illegal fishing in the Arafura Sea based on this new source of information. It is analyzed together with Vessel Monitoring System (VMS) and satellite-based Automatic Identification System (Sat-AIS) data, taking into account their own particularities. From October 2014 to March 2015, i.e. just after the establishment of a new moratorium by the Indonesian authorities, the estimated share of fishing vessels not carrying VMS, thus being illegal, ranges from 42 to 47%. One year later in January 2016, this proportion decreases and ranges from 32 to 42%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Mechanical ventilation in children.

    Science.gov (United States)

    Kendirli, Tanil; Kavaz, Asli; Yalaki, Zahide; Oztürk Hişmi, Burcu; Derelli, Emel; Ince, Erdal

    2006-01-01

    Mechanical ventilation can be lifesaving, but > 50% of complications in conditions that require intensive care are related to ventilatory support, particularly if it is prolonged. We retrospectively evaluated the medical records of patients who had mechanical ventilation in the Pediatric Intensive Care Unit (PICU) during a follow-up period between January 2002-May 2005. Medical records of 407 patients were reviewed. Ninety-one patients (22.3%) were treated with mechanical ventilation. Ages of all patients were between 1-180 (median: 8) months. The mechanical ventilation time was 18.8 +/- 14.1 days. Indication of mechanical ventilation could be divided into four groups as respiratory failure (64.8%), cardiovascular failure (19.7%), central nervous system disease (9.8%) and safety airway (5.4%). Tracheostomy was performed in four patients. The complication ratio of mechanically ventilated children was 42.8%, and diversity of complications was as follows: 26.3% atelectasia, 17.5% ventilator-associated pneumonia, 13.1% pneumothorax, 5.4% bleeding, 4.3% tracheal edema, and 2.1% chronic lung disease. The mortality rate of mechanically ventilated patients was 58.3%, but the overall mortality rate in the PICU was 12.2%. In conclusion, there are few published epidemiological data on the follow-up results and mortality in infants and children who are mechanically ventilated.

  11. Control and prevention of ice formation and accretion on heat exchangers for ventilation systems

    DEFF Research Database (Denmark)

    Rahimi, Maral; Afshari, Alireza

    2015-01-01

    In cold climates, the application of mechanical ventilation systems with heat recovery like are airto-air exchangers is used for reducing energy consumption for heating buildings by transferring heat exhausted air to supply air. However, increase efficiency of heat exchanger results in lower...... exhaust air temperatures and Ice formation on heat exchanger fins, which can cause problem and is not favourable. Therefore, prevention and control of ice formation on heat exchangers is necessary. The existing methods are divided into two different methods: active and passive ice control methods....... The active methods are e.g. bypass, recirculation, preheating. The passive methods relate to the surface characteristics of the heat exchanger fins as they have effect on ice formation in initial phase. All these methods have varying levels of success, cost, and effectiveness, which are depending on the heat...

  12. Conceptual design of the handling and storage system of the spent target vessel for neutron scattering facility 2

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Junichi; Kaminaga, Masanori; Sasaki, Shinobu; Haga, Katsuhiro; Aso, Tomokazu; Kinoshita, Hidetaka; Hino, Ryutaro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-01-01

    In designing the neutron scattering facility, a spent target vessel should be replaced with remote handling devices in order to protect radioactive exposure, since it would be highly activated through the high energy neutron irradiation caused by the spallation reaction between mercury of the target material and the MW-class proton beam. In the storage of the spent target vessel, it is necessary to consider decay heat of the target vessel and mercury contamination caused by vaporization of the residual mercury in the vessel. A conceptual design has been carried out to establish basic concept and to clarify its specification of main equipments on handling and storage systems for the spent target vessel. This report presents the basic concept and a system plot plan based on latest design works of remote handling devices such as a spent target vessel storage cask and a target vessel exchange trolley, which aim at reasonability and simplification. In addition, storage systems for the spent moderator vessel, the spent proton beam window and the spent reflector vessel are also investigated based on the plot plan. (author)

  13. Clinical experience and incidence of ventilator-associated pneumonia using closed versus open suction-system.

    Science.gov (United States)

    Åkerman, Eva; Larsson, Catharina; Ersson, Anders

    2014-01-01

    Studies have shown a decreasing ventilator-associated pneumonia (VAP) incidence after prophylactic interventions bundles. The use of closed suction systems (CSS) has been suggested beneficial as a prophylactic measure. To investigate the effects of a CSS on VAP incidence, suction circuit contamination and adverse events (AEs) compared to an open suction system (OSS) approach in a general mixed intensive care unit (ICU). Adult patients on mechanical ventilation were consecutively included. Data were collected during four 1-month periods where CSS and OSS were used on an alternating basis. Airway cultures were obtained at intubation, after 72 h and every Monday. After changing CSS and at extubation, the catheter tip was cultured. AEs and desaturation events during suction were monitored. Descriptive analysis and differences between the groups were analysed using comparative methods. No differences in airway colonization at admission between the groups were detected (Table 2). The CSS group had a higher Simplified Acute Physiology Score (SAPS) III and also a non-significant increase in VAP incidence. Positive cultures were obtained in 50% of all the retrieved CSS catheters. There was no inter-patient contamination in either group. Six AEs versus one (CSS/OSS) related to tube-occlusion and secretion clogging was seen. Desaturations at suctioning were rare in both groups. No beneficial effects were seen on VAP incidence or inter-patient contamination compared to OSS. A high frequency of circuit contamination in the CSS group paralleled with experienced secretions clearance problems seem unfavourable and in concordance with previous studies. © 2013 The Authors. Nursing in Critical Care © 2013 British Association of Critical Care Nurses.

  14. The Impact of an Extensive Usage of Controlled Natural Ventilation in the Residential Sector on Large-Scale Energy Systems

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan

    energy in the world. Of this energy consumption, one of the highest energy-consuming activities within the buildings is concerning cooling. Technologies such as mechanical ventilation and air-conditioning are very used to achieve a certain thermal comfort within the building when there are periods...... simulation program and an energy systems analysis model are used as tools. The residential sectors of Denmark – temperate conditions – and Mexico – warm conditions – are used as case studies. In both scenarios, potential energy savings are assessed after using natural ventilation. Thereafter, environmental...

  15. Impact of ventilation systems and energy savings in a building on the mechanisms governing the indoor radon activity concentration.

    Science.gov (United States)

    Collignan, Bernard; Powaga, Emilie

    2017-11-23

    For a given radon potential in the ground and a given building, the parameters affecting the indoor radon activity concentration (IRnAC) are indoor depressurization of a building and its air change rate. These parameters depend mainly on the building characteristics, such as airtightness, and on the nature and performances of the ventilation system. This study involves a numerical sensitivity assessment of the indoor environmental conditions on the IRnAC in buildings. A numerical ventilation model has been adapted to take into account the effects of variations in the indoor environmental conditions (depressurization and air change rate) on the radon entry rate and on the IRnAC. In the context of the development of a policy to reduce energy consumption in a building, the results obtained showed that IRnAC could be strongly affected by variations in the air permeability of the building associated with the ventilation regime. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Blood-Vessel-on-a-Chip Platforms for Evaluating Nanoparticle Drug Delivery Systems.

    Science.gov (United States)

    Li, Yuancheng; Zhu, Kai; Liu, Xiao; Zhang, Y Shrike

    2017-09-24

    Nanoparticle-based drug delivery systems hold great promise for the treatment of major diseases. However, their slow translation from bench to the clinic posts a serious concern. It is mainly attributed to the lack of suitable in vitro platforms for rapid and accurate screening of nanomedicine. Recent developments in microfluidic technologies have provided the possibility to reproduce the biomimetic blood vessel microenvironments outside the body, thus offering a convenient means to characterize the in vivo dynamics and biological responses of nanoparticles. In this review, we discuss the challenges facing the field of nanoparticle drug delivery and highlight the urgent need for construction of blood-vessel-on-a-chip platforms for testing nanomedicine. We subsequently illustrate advances in fabricating various well-controlled blood-vessel-on-a-chip platforms, covering a few examples that have used such models for evaluating nanoparticles behaviors. We then summarize with conclusions and perspectives. We anticipate that, further development of these blood-vessel-on-a-chip platforms with improved biomimetic parameters, tissue specificity, and personalization, will enable their wide applications in drug screening including nanomedicine. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. Researches Regarding the Efficiency of Water to Air Heat Exchanger with Heat Pipes for the Mechanical Ventilation System

    OpenAIRE

    Andrei Burlacu; Theodor Mateescu

    2007-01-01

    The present paper proposes the analysis of the efficiency of water to air heat exchanger with heat pipes for the mechanical ventilation system. The performed study is based on the necessity of the unconventional energy forms capitalization, increasing of the energy efficiency and the energy consumption decrease in concordance with the sustainable development concept.

  18. HOW THE LEED VENTILATION CREDIT IMPACTS ENERGY CONSUMPTION OF GSHP SYSTEMS A CASE STUDY FOR PRIMARY SCHOOLS

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL

    2011-01-01

    This paper presents a study on the impacts of increased outdoor air (OA) ventilation on the performance of ground-source heat pump (GSHP) systems that heat and cool typical primary schools. Four locations Phoenix, Miami, Seattle, and Chicago are selected in this study to represent different climate zones in the United States. eQUEST, an integrated building and HVAC system energy analysis program, is used to simulate a typical primary school and the GSHP system at the four locations with minimum and 30% more than minimum OA ventilation. The simulation results show that, without an energy recovery ventilator, the 30% more OA ventilation results in an 8.0 13.3% increase in total GSHP system energy consumption at the four locations. The peak heating and cooling loads increase by 20.2 30% and 14.9 18.4%, respectively, at the four locations. The load imbalance of the ground heat exchanger is increased in hot climates but reduced in mild and cold climates.

  19. Removal of Particles from the Supply Air of Ventilation Systems Avoiding the Formation of Sensory Pollution Source

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2008-01-01

    an important role. Sensory pollutants emitted from used filters can have significant adverse impact on occupant performance. Therefore, removal of particles from the supply air of ventilation systems without the subsequent emission of pollutants into the airstream seems to be essential. Correct maintenance...

  20. Researches Regarding the Efficiency of Water to Air Heat Exchanger with Heat Pipes for the Mechanical Ventilation System

    Directory of Open Access Journals (Sweden)

    Andrei Burlacu

    2007-01-01

    Full Text Available The present paper proposes the analysis of the efficiency of water to air heat exchanger with heat pipes for the mechanical ventilation system. The performed study is based on the necessity of the unconventional energy forms capitalization, increasing of the energy efficiency and the energy consumption decrease in concordance with the sustainable development concept.

  1. Ontology for Life-Cycle Modeling of Heating, Ventilating, and Air Conditioning (HVAC) Systems: Experimental Applications Using Revit

    Science.gov (United States)

    2012-03-01

    Center, Construction Engineering Research Laboratory (ERDC-CERL) has developed a core life- cycle building information model ( BIM ) based on three...was to promote consistency and quality of content created for Building Information Models ( BIMs ) across various disciplines. The HVAC MVD was...MVD. 15. SUBJECT TERMS building information modeling ( BIM ), ontology, Army facilities, heating, ventilating, and air-conditioning (HVAC) systems

  2. JACoW Virtual control commissioning for a large critical ventilation system: The CMS cavern use case

    CERN Document Server

    Booth, William; Bradu, Benjamin; Sourisseau, Samuel

    2018-01-01

    The current cavern ventilation control system of the CMS experiment at CERN is based on components which are already obsolete: the SCADA system, or close to the end of life: the PLCs. The control system is going to be upgraded during the LHC Long Shutdown 2 (2019-2020) and will be based on the CERN industrial control standard: UNICOS employing WinCC OA as SCADA and Schneider PLCs. Due to the critical nature of the CMS ventilation installation and the short allowed downtime, the approach was to design an environment based on the virtual commissioning of the new control. This solution uses a first principles model of the ventilation system to simulate the real process. The model was developed with the modelling and simulation software EcosimPro. In addition, the current control application of the cavern ventilation will also be re-engineered as it is not completely satisfactory in some transients where many sequences are performed manually and some pressure fluctuations observed could potentially cause issues t...

  3. Experimental Investigation of Convective Heat Transfer during Night Cooling with Different Ventilation Systems and Surface Emissivities

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2013-01-01

    Night-time ventilation is a promising approach to reduce the energy needed for cooling buildings without reducing thermal comfort. Nevertheless actual building simulation tools have showed their limits in predicting accurately the efficiency of night-time ventilation, mainly due to inappropriate ...

  4. Prestressed-concrete pressure vessels and their applicability to advanced-energy-system concepts

    Energy Technology Data Exchange (ETDEWEB)

    Naus, D.J

    1983-01-01

    Prestressed concrete pressure vessels (PCPVs) are, in essence, spaced steel structures since their strength is derived from a multitude of steel elements made up of deformed reinforcing bars and prestressing tendons which are present in sufficient quantities to carry tension loads imposed on the vessel. Other major components of a PCPV include the concrete, liner and cooling system, and insulation. PCPVs exhibit a number of advantages which make them ideally suited for application to advanced energy concepts: fabricability in virtually any size and shape using available technology, improved safety, reduced capital costs, and a history of proven performance. PCPVs have many applications to both nuclear- and non-nuclear-based energy systems concepts. Several of these concepts will be discussed as well as the research and development activities conducted at ORNL in support of PCPV development.

  5. Optimization of Composite Material System and Lay-up to Achieve Minimum Weight Pressure Vessel

    Science.gov (United States)

    Mian, Haris Hameed; Wang, Gang; Dar, Uzair Ahmed; Zhang, Weihong

    2013-10-01

    The use of composite pressure vessels particularly in the aerospace industry is escalating rapidly because of their superiority in directional strength and colossal weight advantage. The present work elucidates the procedure to optimize the lay-up for composite pressure vessel using finite element analysis and calculate the relative weight saving compared with the reference metallic pressure vessel. The determination of proper fiber orientation and laminate thickness is very important to decrease manufacturing difficulties and increase structural efficiency. In the present work different lay-up sequences for laminates including, cross-ply [ 0 m /90 n ] s , angle-ply [ ±θ] ns , [ 90/±θ] ns and [ 0/±θ] ns , are analyzed. The lay-up sequence, orientation and laminate thickness (number of layers) are optimized for three candidate composite materials S-glass/epoxy, Kevlar/epoxy and Carbon/epoxy. Finite element analysis of composite pressure vessel is performed by using commercial finite element code ANSYS and utilizing the capabilities of ANSYS Parametric Design Language and Design Optimization module to automate the process of optimization. For verification, a code is developed in MATLAB based on classical lamination theory; incorporating Tsai-Wu failure criterion for first-ply failure (FPF). The results of the MATLAB code shows its effectiveness in theoretical prediction of first-ply failure strengths of laminated composite pressure vessels and close agreement with the FEA results. The optimization results shows that for all the composite material systems considered, the angle-ply [ ±θ] ns is the optimum lay-up. For given fixed ply thickness the total thickness of laminate is obtained resulting in factor of safety slightly higher than two. Both Carbon/epoxy and Kevlar/Epoxy resulted in approximately same laminate thickness and considerable percentage of weight saving, but S-glass/epoxy resulted in weight increment.

  6. Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation

    Directory of Open Access Journals (Sweden)

    Carlo Massaroni

    2017-04-01

    Full Text Available During mechanical ventilation, the humidification of the dry air delivered by the mechanical ventilator is recommended. Among several solutions, heated wire humidifiers (HWHs have gained large acceptance to be used in this field. The aim of this work is to fabricate a measuring system based on fiber Bragg grating (FBG for the simultaneous monitoring of gas relative humidity (RH and temperature, intended to be used for providing feedback to the HWHs’ control. This solution can be implemented using an array of two FBGs having a different center wavelength. Regarding RH monitoring, three sensors have been fabricated by coating an FBG with two different moisture-sensitive and biocompatible materials: the first two sensors were fabricated by coating the grating with a 3 mm × 3 mm layer of agar and agarose; to investigate the influence of the coating thickness to the sensor response, a third sensor was developed with a 5 mm × 5 mm layer of agar. The sensors have been assessed in a wide range of RH (up to 95% during both an ascending and a subsequent descending phase. Only the response of the 3 mm × 3 mm-coated sensors were fast enough to follow the RH changes, showing a mean sensitivity of about 0.14 nm/% (agar-coated and 0.12 nm/% (agarose-coated. The hysteresis error was about <10% in the two sensors. The contribution of temperature changes on these RH sensors was negligible. The temperature measurement was performed by a commercial FBG insensitive to RH changes. The small size of these FBG-based sensors, the use of biocompatible polymers, and the possibility to measure both temperature and RH by using the same fiber optic embedding an array of two FBGs make intriguing the use of this solution for application in the control of HWHs.

  7. Mild hypothermia attenuates changes in respiratory system mechanics and modifies cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation.

    Science.gov (United States)

    Dostál, P; Senkeřík, M; Pařízková, R; Bareš, D; Zivný, P; Zivná, H; Cerný, V

    2010-01-01

    Hypothermia was shown to attenuate ventilator-induced lung injury due to large tidal volumes. It is unclear if the protective effect of hypothermia is maintained under less injurious mechanical ventilation in animals without previous lung injury. Tracheostomized rats were randomly allocated to non-ventilated group (group C) or ventilated groups of normothermia (group N) and mild hypothermia (group H). After two hours of mechanical ventilation with inspiratory fraction of oxygen 1.0, respiratory rate 60 min(-1), tidal volume 10 ml x kg(-1), positive end-expiratory pressure (PEEP) 2 cm H2O or immediately after tracheostomy in non-ventilated animals inspiratory pressures were recorded, rats were sacrificed, pressure-volume (PV) curve of respiratory system constructed, bronchoalveolar lavage (BAL) fluid and aortic blood samples obtained. Group N animals exhibited a higher rise in peak inspiratory pressures in comparison to group H animals. Shift of the PV curve to right, higher total protein and interleukin-6 levels in BAL fluid were observed in normothermia animals in comparison with hypothermia animals and non-ventilated controls. Tumor necrosis factor-alpha was lower in the hypothermia group in comparison with normothermia and non-ventilated groups. Mild hypothermia attenuated changes in respiratory system mechanics and modified cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation in animals without previous lung injury.

  8. NASA Requirements for Ground-Based Pressure Vessels and Pressurized Systems (PVS). Revision C

    Science.gov (United States)

    Greulich, Owen Rudolf

    2017-01-01

    The purpose of this document is to ensure the structural integrity of PVS through implementation of a minimum set of requirements for ground-based PVS in accordance with this document, NASA Policy Directive (NPD) 8710.5, NASA Safety Policy for Pressure Vessels and Pressurized Systems, NASA Procedural Requirements (NPR) 8715.3, NASA General Safety Program Requirements, applicable Federal Regulations, and national consensus codes and standards (NCS).

  9. Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M.A.; D.A. Springer

    2008-06-18

    The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the

  10. Design Procedure for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Tjelflaat, Per Olaf

    Mechanical and natural ventilation systems have developed separately during many years. The natural next step in this development is development of ventilation concepts that utilises and combines the best features from each system into a new type of ventilation system - Hybrid Ventilation....... Buildings with hybrid ventilation often include other sustainable technologies and an energy optimisation requires an integrated approach in the design of the building and its mechanical systems. Therefore, the hybrid ventilation design procedure differs from the design procedure for conventional HVAC....... The first ideas on a design procedure for hybrid ventilation is presented and the different types of design methods, that is needed in different phases of the design process, is discussed....

  11. Slurry Ice as a Cooling System on 30 GT Fishing Vessel

    Directory of Open Access Journals (Sweden)

    Alam Baheramsyah

    2017-06-01

    Full Text Available Indonesia is the largest archipelago country in the world that has a sea area that is very spacious. Indonesian sea area is 5.8 million square kilometers and a coastline of 95 181 km has huge potential in the fisheries sector. In line with the need to further improve on the quality of the fish catch. One way to preserve fish is to use a slurry of ice. Slurry ice proved more effective preserving fishery products instead of using ice cubes. Ice slurry cooling system was designed and applied to the fishing vessel 30 GT. The cooling system uses a simple vapor compression system consists of five major components consisting of evaporator, condenser, compressor, and two pumps.In designing this system determined the type of refrigerant used in advance which type of refrigerant R-507a. Then do the design or selection of its main components. The design is only done on the evaporator. As for the other major components such as condensers, compressors, and pumps election in accordance with the specification of the power needed. After that dialakukan depiction of each system component. Then subsequently designing the laying of ice slurry cooling system components on a fishing vessel 30 GT.            Through calculations using simple thermodynamic equations obtained cooling load on this system amounted to 32.06 kW. Condenser with a power of 40 kW. Compressor with power 12 kW. Pump with capacity 10 m3 / h. With memepertimbangkan space left on the ship in the ice slurry system design on the main deck of the ship to the efficient use of space on board. The power requirements of the generator vessel increases due to the addition of ice slurry system components therefore do replacement generator into the generator with a power of 100 kW and penambahn fuel tank to 6,000 L.

  12. Ventilation and Heart Rate Monitoring in Drivers using a Contactless Electrical Bioimpedance System

    Science.gov (United States)

    Macías, R.; García, M. A.; Ramos, J.; Bragós, R.; Fernández, M.

    2013-04-01

    Nowadays, the road safety is one of the most important priorities in the automotive industry. Many times, this safety is jeopardized because of driving under inappropriate states, e.g. drowsiness, drugs and/or alcohol. Therefore several systems for monitoring the behavior of subjects during driving are researched. In this paper, a device based on a contactless electrical bioimpedance system is shown. Using the four-wire technique, this system is capable of obtaining the heart rate and the ventilation of the driver through multiple textile electrodes. These textile electrodes are placed on the car seat and the steering wheel. Moreover, it is also reported several measurements done in a controlled environment, i.e. a test room where there are no artifacts due to the car vibrations or the road state. In the mentioned measurements, the system response can be observed depending on several parameters such as the placement of the electrodes or the number of clothing layers worn by the driver.

  13. Measurement of contrast of phantom and in vivo subsurface blood vessels using two near-infrared imaging systems

    Science.gov (United States)

    Hebden, Jeremy C.; Alkhaja, Aysha; Mahe, Laure; Powell, S.; Everdell, N. L.

    2015-03-01

    A quantitative comparison has been performed between two commercial near-infrared (NIR) vein-viewing systems which are designed to supplement the clinician's traditional skills in locating veins by means of visualization and palpation. The AccuVein AV300 and Novarix IV-eye real-time imaging systems employ very different imaging geometries; the former generates an image from reflected NIR light produced by a beam scanned across the surface, while the latter illuminates the viewed region at four points on the periphery and records the resulting distribution of diffusely transmitted light. The comparison involved measuring the contrast produced by absorbing rods (simulated blood vessels) in a cylindrical phantom with tissue-like optical properties, and the contrast of superficial blood vessels in the arms of healthy volunteers. The locations and sizes of the blood vessels were independently verified using a clinical ultrasound imaging system. The phantom measurements suggested that the AV300 displays the most superficial vessels with greater contrast, but the IV-eye is able to detect vessels when they are at a depth up to 2 mm greater than the limit observed for the AV300. The results for thirty healthy volunteers also indicated that the AV300 typically displays vessels with higher overall contrast, but the effectiveness of the IV-eye at visualizing deeper vessels was even more pronounced, with a maximum depth several millimeters greater than that achieved by the AV300, and more than ten times as many vessels observed at depths below 4 mm.

  14. [Assessment of the air quality improment of cleaning and disinfection on central air-conditioning ventilation system].

    Science.gov (United States)

    Liu, Hongliang; Zhang, Lei; Feng, Lihong; Wang, Fei; Xue, Zhiming

    2009-09-01

    To assess the effect of air quality of cleaning and disinfection on central air-conditioning ventilation systems. 102 air-conditioning ventilation systems in 46 public facilities were sampled and investigated based on Hygienic assessment criterion of cleaning and disinfection of public central air-conditioning systems. Median dust volume decreased from 41.8 g/m2 to 0.4 g/m2, and the percentage of pipes meeting the national standard for dust decreased from 17.3% (13/60) to 100% (62/62). In the dust, median aerobic bacterial count decreased from 14 cfu/cm2 to 1 cfu/cm2. Median aerobic fungus count decreased from 10 cfu/cm2 to 0 cfu/cm2. The percentage of pipes with bacterial and fungus counts meeting the national standard increased from 92.4% (171/185) and 82.2% (152/185) to 99.4% (165/166) and 100% (166/166), respectively. In the ventilation air, median aerobic bacterial count decreased from 756 cfu/m3 to 229 cfu/m3. Median aerobic fungus count decreased from 382 cfu/m3 to 120 cfu/m3. The percentage of pipes meeting the national standard for ventilation air increased from 33.3% (81/243) and 62.1% (151/243) to 79.8% (292/366) and 87.7% (242/276), respectively. But PM10 rose from 0.060 mg/m3 to 0.068 mg/m3, and the percentage of pipes meeting the national standard for PM10 increased from 74.2% (13/60) to 90.2% (46/51). The cleaning and disinfection of central air-conditioning ventilation systems could have a beneficial effect of air quality.

  15. Dynamic and quasi-static lung mechanics system for gas-assisted and liquid-assisted ventilation.

    Science.gov (United States)

    Alvarez, Francisco J; Gastiasoro, Elena; Rey-Santano, M Carmen; Gomez-Solaetxe, Miguel A; Publicover, Nelson G; Larrabe, Juan L

    2009-07-01

    Our aim was to develop a computerized system for real-time monitoring of lung mechanics measurements during both gas and liquid ventilation. System accuracy was demonstrated by calculating regression and percent error of the following parameters compared to standard device: airway pressure difference (Delta P(aw)), respiratory frequency (f(R) ), tidal volume (V(T)), minute ventilation (V'(E)), inspiratory and expiratory maximum flows (V'(ins,max), V'(exp,max)), dynamic lung compliance (C(L,dyn) ), resistance of the respiratory system calculated by method of Mead-Whittenberger (R(rs,MW)) and by equivalence to electrical circuits (R(rs,ele)), work of breathing (W(OB)), and overdistension. Outcome measures were evaluated as function of gas exchange, cardiovascular parameters, and lung mechanics including mean airway pressure (mP(aw)). Delata P(aw), V(T), V'(ins,max), V'(exp,max), and V'(E) measurements had correlation coefficients r = 1.00, and %error or = 0.98 and %error ventilated groups had increased mP(aw) and W(OB), with decreased V(T), V'(E), C(L,dyn), R(rs,MW), and R(rs,ele) compared to controls. After 1-h ventilation, both injured group had decreased V(T), V'(E) , and C(L,dyn), with increased mP(aw), R(rs,MW), R(rs,ele), and W(OB) . In lung-injured animals, liquid ventilation restored gas exchange, and cardiovascular and lung functions. Our lung mechanics system was able to closely monitor pulmonary function, including during transitions between gas and liquid phases.

  16. The effects of individually ventilated cages on the respiratory systems of male and female Wistar rats from birth until adulthood.

    Science.gov (United States)

    Marchesi, Guilherme D'Aprile; Soto, Sônia de Fatima; Castro, Isac de; Rodrigues, Thiago Guimarães; Moriya, Henrique Takachi; Almeida, Francine Maria de; Pazetti, Rogerio; Heimann, Joel Claudio; Furukawa, Luzia Naôko Shinohara

    2017-03-01

    To evaluate the respiratory systems of male and female rats maintained in individually ventilated cages (IVCs) from birth until adulthood. Female Wistar rats were housed in individually ventilated cages or conventional cages (CCs) and mated with male Wistar rats. After birth and weaning, the male offspring were separated from the females and kept in cages of the same type until 12 weeks of age. The level of food consumption was lower in male offspring (IVC=171.7±9; CC=193.1±20) than in female offspring (IVC=100.6±7; CC=123.4±0.4), whereas the water intake was higher in female offspring (IVC=149.8±11; CC=99.2±0) than in male offspring (IVC=302.5±25; CC=249.7±22) at 11 weeks of age when housed in IVCs. The cage temperature was higher in individually ventilated cages than in conventional cages for both male (IVCs=25.9±0.5; CCs=22.95±0.3) and female (IVCs=26.2±0.3; CCs=23.1±0.3) offspring. The respiratory resistance (IVC=68.8±2.8; CC=50.6±3.0) and elastance (IVC=42.0±3.9; CC=32.4±2.0) at 300 µm/kg were higher in the female offspring housed in ventilated cages. The ciliary beat values were lower in both the male (IVCs=13.4±0.2; CC=15±0.4) and female (IVC=13.5±0.4; CC=15.9±0.6) offspring housed in individually ventilated cages than in those housed in conventional cages. The total cell (IVC=117.5±9.7; CC=285.0±22.8), neutrophil (IVC=13.1±4.8; CC=75.6±4.1) and macrophage (IVC=95.2±11.8; CC=170.0±18.8) counts in the bronchoalveolar lavage fluid were lower in the female offspring housed in individually ventilated cages than in those housed in conventional cages. The environmental conditions that exist in individually ventilated cages should be considered when interpreting the results of studies involving laboratory animals. In this study, we observed gender dimorphism in both the water consumption and respiratory mechanics of rats kept in ventilated cages.

  17. The effects of individually ventilated cages on the respiratory systems of male and female Wistar rats from birth until adulthood

    Directory of Open Access Journals (Sweden)

    Guilherme D’Aprile Marchesi

    Full Text Available OBJECTIVE: To evaluate the respiratory systems of male and female rats maintained in individually ventilated cages (IVCs from birth until adulthood. METHODS: Female Wistar rats were housed in individually ventilated cages or conventional cages (CCs and mated with male Wistar rats. After birth and weaning, the male offspring were separated from the females and kept in cages of the same type until 12 weeks of age. RESULTS: The level of food consumption was lower in male offspring (IVC=171.7±9; CC=193.1±20 than in female offspring (IVC=100.6±7; CC=123.4±0.4, whereas the water intake was higher in female offspring (IVC=149.8±11; CC=99.2±0 than in male offspring (IVC=302.5±25; CC=249.7±22 at 11 weeks of age when housed in IVCs. The cage temperature was higher in individually ventilated cages than in conventional cages for both male (IVCs=25.9±0.5; CCs=22.95±0.3 and female (IVCs=26.2±0.3; CCs=23.1±0.3 offspring. The respiratory resistance (IVC=68.8±2.8; CC=50.6±3.0 and elastance (IVC=42.0±3.9; CC=32.4±2.0 at 300 µm/kg were higher in the female offspring housed in ventilated cages. The ciliary beat values were lower in both the male (IVCs=13.4±0.2; CC=15±0.4 and female (IVC=13.5±0.4; CC=15.9±0.6 offspring housed in individually ventilated cages than in those housed in conventional cages. The total cell (IVC=117.5±9.7; CC=285.0±22.8, neutrophil (IVC=13.1±4.8; CC=75.6±4.1 and macrophage (IVC=95.2±11.8; CC=170.0±18.8 counts in the bronchoalveolar lavage fluid were lower in the female offspring housed in individually ventilated cages than in those housed in conventional cages. CONCLUSIONS: The environmental conditions that exist in individually ventilated cages should be considered when interpreting the results of studies involving laboratory animals. In this study, we observed gender dimorphism in both the water consumption and respiratory mechanics of rats kept in ventilated cages.

  18. Nuclear analysis and shielding optimisation in support of the ITER In-Vessel Viewing System design

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Andrew, E-mail: andrew.turner@ccfe.ac.uk [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Pampin, Raul [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Loughlin, M.J. [ITER Organisation, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Ghani, Zamir; Hurst, Gemma [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Lo Bue, Alessandro [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Mangham, Samuel [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Puiu, Adrian [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Zheng, Shanliang [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)

    2014-10-15

    The In-Vessel Viewing System (IVVS) units proposed for ITER are deployed to perform in-vessel examination. During plasma operations, the IVVS is located beyond the vacuum vessel, with shielding blocks envisaged to protect components from neutron damage and reduce shutdown dose rate (SDR) levels. Analyses were conducted to determine the effectiveness of several shielding configurations. The neutron response of the system was assessed using global variance reduction techniques and a surface source, and shutdown dose rate calculations were undertaken using MCR2S. Unshielded, the absorbed dose to piezoelectric motors (PZT) was found to be below stable limits, however activation of the primary closure plate (PCP) was prohibitively high. A scenario with shielding blocks at probe level showed significantly reduced PCP contact dose rate, however still marginally exceeded port cell requirements. The addition of shielding blocks at the bioshield plug demonstrated PCP contact dose rates below project requirements. SDR levels in contact with the isolated IVVS cartridge were found to marginally exceed the hands-on maintenance limit. For engineering feasibility, shielding blocks at bioshield level are to be avoided, however the port cell SDR field requires further consideration. In addition, alternative low-activation steels are being considered for the IVVS cartridge.

  19. Coefficients of Propeller-hull Interaction in Propulsion System of Inland Waterway Vessels with Stern Tunnels

    Directory of Open Access Journals (Sweden)

    Jan Kulczyk

    2014-09-01

    Full Text Available Propeller-hull interaction coefficients - the wake fraction and the thrust deduction factor - play significant role in design of propulsion system of a ship. In the case of inland waterway vessels the reliable method of predicting these coefficients in early design stage is missing. Based on the outcomes from model tests and from numerical computations the present authors show that it is difficult to determine uniquely the trends in change of wake fraction and thrust deduction factor resulting from the changes of hull form or operating conditions. Nowadays the resistance and propulsion model tests of inland waterway vessels are carried out rarely because of relatively high costs. On the other hand, the degree of development of computational methods enables’ to estimate the reliable values o interaction coefficients. The computations referred to in the present paper were carried out using the authors’ own software HPSDKS and the commercial software Ansys Fluent.

  20. Small-Medium Vessel Vasculitides: is the Complement System a Potential Forgotten Target?

    Science.gov (United States)

    Ballanti, Eleonora; Chimenti, Maria S; Perricone, Roberto

    2015-02-01

    Systemic vasculitides are a group of uncommon diseases characterized by blood vessel inflammation. The complement system is involved in the pathogenesis and clinical manifestations of several autoimmune diseases, including systemic vasculitides. This enzymatic system is a component of the innate immune system. Its main function was initially believed to be limited to the recognition and elimination of pathogens, but research in recent years has demonstrated the important role that complement proteins play in modulating adaptive immunity and in bridging innate and adaptive responses. Its activation is also critical for the development of T cell immunity and natural antibodies as well as for the regulation of autoreactive B cells. In systemic vasculitides, particularly small-medium vesselvasculitides, the complement system has been shown to contribute to the development of inflammatory damage. In view of these crucial functions, the complement system represents an attractive therapeutic target for a wide range of diseases. including vasculitic disorders.

  1. A static pressure reset control system with a new type of flow damper for use in low pressure ventilation systems

    DEFF Research Database (Denmark)

    Terkildsen, Søren; Svendsen, Svend

    2012-01-01

    The control strategy for mechanical ventilation systems has significant impact on the performance of the system, in terms of energy consumption and correct air distribution. This paper presents a static pressure reset control system employing a new type of flow damper with lower pressure loss...... shows that the droplet shaped damper resulted in an airflow of 234 L/s at 30 Pa pressure loss, more than twice the airflow past a flat-plate damper at the same pressure loss (114 L/s). Also the droplet shaped damper could operate precisely down to 5 Pa pressure loss. The programmed control algorithm...... significant fan power saving compared to a fixed static pressure control. A maximum static pressure of 15 Pa is a reduction of more than 50% compared to flat-plate dampers that required at least 30 Pa to operate precisely; this is expected to yield fan energy savings in practice....

  2. Measurement of HVAC system performance and local ventilation using passive perfluorocarbon tracer technology

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, R.N.; Goodrich, R.W.

    1995-06-01

    In April of 1993, two (2) perfluorocarbon tracer (PFT) ventilation/indoor air quality assessment tests were performed in the Gleeson Hall building of the SUNY Farmingdale campus. The building was being modified, in part, as a result of significant occupant complaints of perceived poor air quality. The four story building had a basement first floor with air supplied normally by an HVAC system labelled as AC1. During this study, AC1 was inoperational and the basement interior rooms (walls) were primarily gone; the other three floors were still being used for classes. It is possible that a sense of poor air quality may have been perceived by first-floor occupants because they were working in the basement, but this issue could not be addressed. The second floor had two (2) lecture halls--Rm 202 (handled by AC4) and Rm 204 (handled by AC5); the balance of the second floor interior rooms and corridors was split between two other air handling systems, AC2 for the west side of the building and AC3 for the east side. The remaining 3rd and 4th floors were also split about evenly between AC2 and AC3. The perimeter rooms, equipped with wall units having their own outside air (OA) source plus centralized return air (RA) bypasses, were not included in this testing which was restricted to the basement floor (1st floor) and the four operating air handling systems, AC2 to AC5, during Test 1 and only AC2 to AC5 during Test 2. Two types of tests were performed using the full suite of 5 PFT types available. The first test was designed to measure the infiltration, exfiltration, and air exchange between the 5 AC zones above and the second test used the 5th tracer, which had been in the basement, as a distributed source throughout the four other zones to act as a surrogate pollutant source. This report provides final conclusions of both tests and suggestions regarding its usefulness in similar building ventilation and indoor air quality assessments.

  3. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  4. Silver zeolite antimicrobial activity in aluminium heating, ventilation and air conditioning system ducts.

    Science.gov (United States)

    Rizzetto, R; Mansi, A; Panatto, D; Rizzitelli, E; Tinteri, C; Sasso, T; Gasparini, R; Crovari, P

    2008-03-01

    Air pollution in confined environments is a serious health problem, in that most people spend long periods indoors (in homes, offices, classrooms etc.). Some people (children, the elderly, heart disease patients, asthmatic or allergic subjects) are at greater risk because of their conditions of frailty. The growing use of air-conditioning systems in many public and private buildings aggravates this health risk, especially when these systems are not correctly installed or regularly serviced. The aim of our study was to verify the capacity of Ag+ ions to stop the growth of bacteria and moulds inside the ducts of Heating, Ventilation and Air Conditioning system ducts (HVAC) systems when these ducts were lined with active Ag+ ions zeolite-coated panels. A Y-shaped HVAC model with two branches was used; one branch was made of traditional galvanized iron, as was the whole system, while the other was lined with active Ag+ zeolite-coated polyurethane panels. During the test, samples of dust present inside both ducts were collected and seeded in liquid and solid media to detect bacteria and moulds. The presence of bacteria was also sought in the air emerging from the outlets of both ducts. Tests made on samples of particulate collected from the two different ducts revealed a lower total bacterial load in the samples collected from the Ag+ zeolite-coated duct than in the samples from the traditional Zn galvanized duct. In addition, the values of bacterial load found in the air emerging from the Ag+ ions zeolite-lined duct were 5 times lower than those found in the air from the traditional galvanized iron duct. The utilization of Ag+ zeolite-coated panels in air-conditioning systems could improve the quality of the emerging air in comparison with traditional installations in galvanized iron. This innovation could prove particularly advantageous in the event of accidents during the installation of air-conditioning systems or of contaminated aerosols coming from outside.

  5. Demand Controlled Ventilation and Classroom Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-05-01

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  6. Demand controlled ventilation and classroom ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-06

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  7. Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    Displacement ventilation is an interesting new type of air distribution principle which should be considered in connection with design of comfort ventilation in both smal1 and large spaces. Research activities on displacement ventilation are large all over the world and new knowledge of design...... methods appears continuously. This book gives an easy introduction to the basis of displacement ventilation and the chapters are written in the order which is used in a design procedure. The main text is extended by five appendices which show some of the new research activities taking place at Aalborg...

  8. High frequency mechanical ventilation affects respiratory system mechanics differently in C57BL/6J and BALB/c adult mice.

    Science.gov (United States)

    Hadden, Hélène

    2013-01-15

    We tested the hypothesis that high frequency ventilation affects respiratory system mechanical functions in C57BL/6J and BALB/c mice. We measured respiratory mechanics by the forced oscillation technique over 1h in anesthetized, intubated, ventilated BALB/c and C57BL/6J male mice. We did not detect any change in airway resistance, Rn, tissue damping, G, tissue elastance, H and hysteresivity, eta in BALB/c mice during 1h of ventilation at 150 or at 450 breaths/min; nor did we find a difference between BALB/c mice ventilated at 150 breaths/min compared with 450 breaths/min. Among C57BL/6J mice, except for H, all parameters remained unchanged over 1h of ventilation in mice ventilated at 150 breaths/min. However, after 10 and 30 min of ventilation at 450 breaths/min, Rn, and respiratory system compliance were lower, and eta was higher, than their starting value. We conclude that high frequency mechanical ventilation affects respiratory system mechanics differently in C57BL/6J and BALB/c adult mice. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Reducing Mortality from Terrorist Releases of Chemical and Biological Agents: I. Filtration for Ventilation Systems in Commercial Building

    Energy Technology Data Exchange (ETDEWEB)

    Thatcher, Tracy L.; Daisey, Joan M.

    1999-09-01

    There is growing concern about potential terrorist attacks involving releases of chemical and/or biological (CB) agents, such as sarin or anthrax, in and around buildings. For an external release, the CB agent can enter the building through the air intakes of a building's mechanical ventilation system and by infiltration through the building envelope. For an interior release in a single room, the mechanical ventilation system, which often recirculates some fraction of the air within a building, may distribute the released CB agent throughout the building. For both cases, installing building systems that remove chemical and biological agents may be the most effective way to protect building occupants. Filtration systems installed in the heating, ventilating and air-conditioning (HVAC) systems of buildings can significantly reduce exposures of building occupants in the event of a release, whether the release is outdoors or indoors. Reduced exposures can reduce the number of deaths from a terrorist attack. The purpose of this report is to provide information and examples of the design of filtration systems to help building engineers retrofit HVAC systems. The report also provides background information on the physical nature of CB agents and brief overviews of the basic principles of particle and vapor filtration.

  10. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (autho0008.

  11. Experimental study on the dynamic performance of a novel system combining natural ventilation with diffuse ceiling inlet and TABS

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo

    2016-01-01

    Highlights • Dynamic experiments are performed to study energy performance of a new HVAC system. • Designed control strategies show good utilization of natural ventilation cooling. • TABS work well with the diffuse ceiling in the dynamic measurements. • No local thermal comfort problem is found...... even in the extreme winter case. • Designed control strategies can be used in the future application of this system....

  12. PCR testing of a ventilated caging system to detect murine fur mites.

    Science.gov (United States)

    Jensen, Eric S; Allen, Kenneth P; Henderson, Kenneth S; Szabo, Aniko; Thulin, Joseph D

    2013-01-01

    Rodents housed in microisolation caging are commonly monitored for infectious agents by the use of soiled bedding sentinels. This strategy relies on the successful transmission of rodent pathogens from the index rodents via soiled bedding to sentinel cages and the subsequent infection or colonization of sentinel rodents. When the prevalence of a pathogen is low or the target agent is not readily transmitted by soiled bedding, alternative testing methodologies should be used. Given the continued prevalence of institutions self-reporting murine fur mites and with the advent of a new sensitive and specific PCR assay for mites, we sought to determine whether the exhaust system of an individual ventilated caging (IVC) system could be used for monitoring the rack's rodent population for mites rather than relying on the responses of sentinels. We deployed single cages of mice (Mus musculus) that were known to be infested with either Radfordia affinis or Myobia musculi on a 70-cage rack, sampled the horizontal exhaust manifolds weekly, and used the new PCR assay to test these samples for mite DNA. We detected the presence of fur mites at a 94.1% probability of detection within 4 wk of placement. Therefore, we recommend swabbing and testing the shelf exhaust manifolds of IVC racks rather than relying on soiled-bedding sentinels as an indicator of the mite status of the rodents on that rack.

  13. Use of Disinfectants and Sanitizers in Heating, Ventilation, Air Conditioning, and Refrigeration Systems

    Science.gov (United States)

    This letter is to brings attention several concerns that the Agency has regarding the use of sanitizer and/or disinfectant products, and other types of antimicrobial products, to treat the surfaces of heating, ventilation

  14. Effectiveness of a personalized ventilation system in reducing personal exposure against directly released simulated cough droplets

    DEFF Research Database (Denmark)

    Pantelic, J.; Tham, K. W.; Licina, Dusan

    2015-01-01

    The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal...... manikin at distances between 1 and 4m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced...... the inhalation intake fraction compared to mixing ventilation for all investigated distances and orientations of the cough release. The results point out that the orientation between the cough source and the breathing zone of the exposed occupant is an important factor that substantially influences exposure...

  15. Mathematical model and minimal measurement system for optimal control of heated humidifiers in neonatal ventilation.

    Science.gov (United States)

    Verta, Antonella; Schena, Emiliano; Silvestri, Sergio

    2010-06-01

    The control of thermo-hygrometric conditions of gas delivered in neonatal mechanical ventilation appears to be a particularly difficult task, mainly due to the vast number of parameters to be monitored and the control strategies of heated humidifiers to be adopted. In the present paper, we describe the heat and fluid exchange occurring in a heated humidifier in mathematical terms; we analyze the sensitivity of the relative humidity of outlet gas as a function of thermo-hygrometric and fluid-dynamic parameters of delivered gas; we propose a control strategy that will enable the stability of outlet gas thermo-hygrometric conditions. The mathematical model is represented by a hyper-surface containing the functional relations between the input variables, which must be measured, and the output variables, which have to remain constant. Model sensitivity analysis shows that heated humidifier efficacy and stability of outlet gas thermo-hygrometric conditions are principally influenced by four parameters: liquid surface temperature, gas flow rate, inlet gas temperature and inlet gas relative humidity. The theoretical model has been experimentally validated in typical working conditions of neonatal applications. The control strategy has been implemented by a minimal measurement system composed of three thermometers, a humidity sensor, and a flow rate sensor, and based on the theoretical model. Outlet relative humidity, contained in the range 90+/-4% and 94+/-4%, corresponding with temperature variations in the range 28+/-2 degrees C and 38+/-2 degrees C respectively, has been obtained in the whole flow rate range typical of neonatal ventilation from 1 to 10 L/min. We conclude that in order to obtain the stability of the thermo-hygrometric conditions of the delivered gas mixture: (a) a control strategy with a more complex measurement system must be implemented (i.e. providing more input variables); (b) and the gas may also need to be pre-warmed before entering the humidifying

  16. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per; Nielsen, Peter V.

    2014-01-01

    As a novel air distribution system, diffuse ceiling ventilation combines the suspended acoustic ceiling with ventilation supply. Due to the low-impulse supply from the large ceiling area, the system does not generate draught when supplying cold air. However, heat sources play an important role on...... temperature as well as optimizing the radiant cooling potential by combining with thermal mass is conducted and gives a direction for further investigation....

  17. Demonstration of the Performance of an Air-Type Photovoltaic Thermal (PVT System Coupled with a Heat-Recovery Ventilator

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2016-09-01

    Full Text Available A heat-recovery ventilator (HRV effectively conducts ventilation by recovering waste heat from indoors to outdoors during heating periods. However, dew condensation associated with the HRV system may arise due to the difference between the indoor temperature and the very low outdoor temperature in winter, and this can decrease the heat exchange efficiency. These problems can be solved by the pre-heating of the incoming air, but additional energy is required when pursuing such a strategy. On the other hand, an air-type photovoltaic thermal (PVT system produces electricity and thermal energy simultaneously using air as the heat transfer medium. Moreover, the heated air from the air-type PVT system can be connected to the HRV to pre-heat the supply air instead of taking in the cold outdoor air. Thus, the ventilation efficiency can be improved and the problems arising during the heating period can be resolved. Consequentially, the heating energy required in a building can be reduced, with additional electricity acquired as well. In this paper, the performance of an air-type PVT system coupled with an HRV is assessed. To do this, air-type PVT collectors operating at 1 kWp were installed in an experimental house and coupled to an HRV system. Thermal performance and heating energy required during the winter season were analyzed experimentally. Furthermore, the electrical performances of the air-type PVT system with and without ventilation at the back side of the PV during the summer season were analyzed.

  18. DETERMINATION OF THE ZONE ENDANGERED BY METHANE EXPLOSION IN GOAF WITH CAVING OF LONGWALLS VENTILATED ON „Y” SYSTEM

    Directory of Open Access Journals (Sweden)

    Jarosław BRODNY

    2016-10-01

    Full Text Available One of the most dangerous and most commonly present risks in hard coal mines is methane hazard. During exploitation by longwall system with caving, methane is emitted to mine heading from the mined coal and coal left in a pile. A large amount of methane also flows from neighboring seams through cracks and fissures formed in rock mass. In a case of accumulation of explosive methane concentration in goaf zone and with appropriate oxygen concentration and occur-rence of initials (e.g. spark or endogenous fire, it may come to the explosion of this gas. In the paper there are present-ed results of numerical analysis of mixture of air and methane streams flow through the real heading system of a mine, characterized by high methane hazard. The aim of the studies was to analyze the ventilation system of considered head-ing system and determination of braking zones in goaf zone, in which dangerous and explosive concertation of methane can occur with sufficient oxygen concentration equal to at least 12%. Determination of position of these zones is neces-sary for the selection of appropriate parameters of the ventilation system to ensure safety of the crew. Analysis of the scale of methane hazard allows to select such a ventilation system of exploitation and neighboring headings that ensures chemical composition of mining atmosphere required by regulation, and required efficiency of methane drainage. The obtained results clearly show that numerical methods, combined with the results of tests in real conditions can be suc-cessfully used for the analysis of variants of processes related to ventilation of underground mining, and also in the anal-ysis of emergency states.

  19. Design and Integrate Improved Systems for Nuclear Facility Ventilation and Exhaust Operations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Murray E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-04-15

    Objective: The objective of this R&D project would complete the development of three new systems and integrate them into a single experimental effort. However, each of the three systems has stand-alone applicability across the DOE complex. At US DOE nuclear facilities, indoor air is filtered and ventilated for human occupancy, and exhaust air to the outdoor environment must be regulated and monitored. At least three technical standards address these functions, and the Los Alamos National Laboratory would complete an experimental facility to answer at least three questions: (1) Can the drag coefficient of a new Los Alamos air mixer be reduced for better operation in nuclear facility exhaust stacks? (2) Is it possible to verify the accuracy of a new dilution method for HEPA filter test facilities? (3) Is there a performance-based air flow metric (volumetric flow or mass flow) for operating HEPA filters? In summary, the three new systems are: a mixer, a diluter and a performance-based metric, respectively. The results of this project would be applicable to at least four technical standards: ANSI N13.1 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities; ASTM F1471 Standard Test Method for Air Cleaning Performance of a High-Efficiency Particulate Air Filter System, ASME N511: In-Service Testing of Nuclear Air Treatment, Heating, Ventilating, and Air-Conditioning Systems, and ASME AG-1: Code On Nuclear Air And Gas Treatment. All of the three proposed new systems must be combined into a single experimental device (i.e. to develop a new function of the Los Alamos aerosol wind tunnel). Technical Approach: The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally (2006) designed to evaluate small air samplers (cf. US EPA 40 CFR 53.42). In 2009, the tunnel was modified for exhaust stack verifications per the ANSI N13.1 standard. In 2010, modifications were started on the

  20. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    -cooling period and night cooling potential. The investment cost of this ventilation system is about 5-10% lower than the conventional ones, because the acoustic ceiling could be directly applied as air diffuser and the use of plenum to distribute air reduces the cost of ductwork. There is a growing interest...... in applying diffuse ceiling ventilation in offices and other commercial buildings because of the benefits from both thermal comfort and energy efficiency aspects. The design guide introduces the principle and key characteristics of room air distribution with diffuse ceiling ventilation and the design...

  1. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    -of-the-art of ventilative cooling potentials and limitations, its consideration in current energy performance regulations, available building components and control strategies and analysis methods and tools. In addition, the report provides twenty six examples of operational buildings using ventilative cooling ranging from...

  2. Ventilation Effectiveness

    DEFF Research Database (Denmark)

    Mundt, M.; Mathisen, H. M.; Moser, M.

    Improving the ventilation effectiveness allows the indoor air quality to be significantly enhanced without the need for higher air changes in the building, thereby avoiding the higher costs and energy consumption associated with increasing the ventilation rates. This Guidebook provides easy...

  3. Total System Performance Assessment- License Appication Design Selection (LADS) Phase 1 Analysis for Post-Closure Ventilation (Design Alternative 3)

    Energy Technology Data Exchange (ETDEWEB)

    N. Erb

    1999-06-21

    The objective of this report is to evaluate the effect of potential changes to the TSPA-VA base case design on long-term repository performance. The design changes that are evaluated in this report include two configurations for post-closure ventilation. bow tie and open loop (Design Alternative 3 or D3). The following paragraphs briefly describe the motivation for evaluating post-closure ventilation. The bow tie configuration for post closure ventilation has been identified as a design alternative to the TSPA-VA base case model (CRWMS M&O, 1998a) that may provide improved performance by reducing the temperature and relative humidity within the waste package drifts. The bow tie configuration for post-closure ventilation is a closed-loop design. In this design. cross drifts are placed in pairs with each drift angling up on opposite sides of the repository. From the side, the cross drifts and side drifts form the shape of a bow tie. Movement of air through the system is driven by convective heating from the waste packages in the cross drifts. The open loop configuration is also being considered for its potential to improve post-closure performance of the repository. As with the bow tie configuration, the open loop is designed to decrease temperature and relative humidity within the waste package drifts. For the open loop configuration, air is drawn into the drifts from outside the mountain. The configuration for the repository with open-loop ventilation is similar to the base case repository design with a few added shafts to increase air flow through the drifts. This report documents the modeling assumptions and calculations conducted to evaluate the long-term performance of Design Alternative 3. The performance measure for this evaluation is dose rate. Results are presented that compare the dose-rate time histories with the new design alternatives to that for the TSPA-VA base case calculation (CRWMS M&O, 1998a).

  4. Inverse Modeling of Respiratory System during Noninvasive Ventilation by Maximum Likelihood Estimation

    Directory of Open Access Journals (Sweden)

    Esra Saatci

    2010-01-01

    Full Text Available We propose a procedure to estimate the model parameters of presented nonlinear Resistance-Capacitance (RC and the widely used linear Resistance-Inductance-Capacitance (RIC models of the respiratory system by Maximum Likelihood Estimator (MLE. The measurement noise is assumed to be Generalized Gaussian Distributed (GGD, and the variance and the shape factor of the measurement noise are estimated by MLE and Kurtosis method, respectively. The performance of the MLE algorithm is also demonstrated by the Cramer-Rao Lower Bound (CRLB with artificially produced respiratory signals. Airway flow, mask pressure, and lung volume are measured from patients with Chronic Obstructive Pulmonary Disease (COPD under the noninvasive ventilation and from healthy subjects. Simulations show that respiratory signals from healthy subjects are better represented by the RIC model compared to the nonlinear RC model. On the other hand, the Patient group respiratory signals are fitted to the nonlinear RC model with lower measurement noise variance, better converged measurement noise shape factor, and model parameter tracks. Also, it is observed that for the Patient group the shape factor of the measurement noise converges to values between 1 and 2 whereas for the Control group shape factor values are estimated in the super-Gaussian area.

  5. Computational fluid dynamics simulation of an earth-air heat exchanger for ventilation system

    Science.gov (United States)

    Raczkowski, Andrzej; Suchorab, Zbigniew; Czechowska-Kosacka, Aneta

    2017-07-01

    Directive 2010/31/EU (EPBD Recast) obligates European Union members to improve energetic performance of the buildings. One of the crucial standards of energy-saving buildings are the passive houses, which are characterized by annual maximum space heating below 15 kWh/(m2.a) and the use of the specific primary energy for all domestic applications (also heating, hot water production and electricity) below 120 kWh/(m2.a). To achieve this standard there should be applied the solutions based on ground energy acquisition. One of them is the earth-air heat exchanger (EAHC) for ventilation systems. The article presents numerical simulations conducted by solving partial differential equations for three dimensional heat transfer. For the simulations it was applied Computational Fluid Dynamics (CFD) technique. The efficiency of EAHC was considered under different values of external temperature during the winter period (from -24 to -8 °C). Obtained results prove linear correlation with calculations of EAHC according to standards of the Polish National Energy Conservation Agency (NAPE). The slope of regression between outlet temperatures calculated with CFD model and NAPE standards, equals 0.59 which means, that according the CFD model, the efficiency of the exchanger is lower.

  6. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Qutaiba A. Tawfic

    2011-01-01

    Full Text Available Mammals have lungs to breathe air and they have no gills to breath liquids. When the surface tension at the air-liquid interface of the lung increases, as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen, as the inert carrier of oxygen and carbon dioxide offers a number of theoretical advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. The potential for multiple clinical applications for liquid-assisted ventilation will be clarified and optimized in future. Keywords: Liquid ventilation; perfluorochemicals; perfluorocarbon; respiratory distress; surfactant.

  7. Patient-ventilator dyssynchrony during assisted invasive mechanical ventilation.

    Science.gov (United States)

    Murias, G; Villagra, A; Blanch, L

    2013-04-01

    Patient-ventilator dyssynchrony is common during mechanical ventilation. Dyssynchrony decreases comfort, prolongs mechanical ventilation and intensive care unit stays, and might lead to worse outcome. Dyssynchrony can occur during the triggering of the ventilator, the inspiration period after triggering, the transition from inspiration to expiration, and the expiratory phase. The most common dyssynchronies are delayed triggering, autotriggering, ineffective inspiratory efforts (which can occur at any point in the respiratory cycle), mismatch between the patient's and ventilator's inspiratory times, and double triggering. At present, the detection of dyssynchronies usually depends on healthcare staff observing ventilator waveforms; however, performance is suboptimal and many events go undetected. To date, technological complexity has made it impossible to evaluate patient-ventilator synchrony throughout the course of mechanical ventilation. Studies have shown that a high index of dyssynchrony may increase the duration of mechanical ventilation. Better training, better ventilatory modes, and/or computerized systems that permit better synchronization of patients' demands and ventilator outputs are necessary to improve patient-ventilator synchrony.

  8. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined...... air heating and ventilation system in a high performance single family house using BSim simulation software. The provision of the desired thermal conditions in different rooms was examined. Results show that the new control strategy can facilitate maintaining of desired temperatures in various rooms....... Moreover, this control strategy enables controlled temperature differentiation between rooms within the house and therefore provides flexibility and better balance in heat delivery. Consequently, the thermal conditions in the building can be improved....

  9. Morphometric analysis of rat femoral vessels under a video magnification system

    Directory of Open Access Journals (Sweden)

    Rui Sergio Monteiro de Barros

    Full Text Available Abstract The right femoral vessels of 80 rats were identified and dissected. External lengths and diameters of femoral arteries and femoral veins were measured using either a microscope or a video magnification system. Findings were correlated to animals’ weights. Mean length was 14.33 mm for both femoral arteries and femoral veins, mean diameter of arteries was 0.65 mm and diameter of veins was 0.81 mm. In our sample, rats’ body weights were only correlated with the diameter of their femoral veins.

  10. [Biological contamination in office buildings related to ventilation/air conditioning system].

    Science.gov (United States)

    Bródka, Karolina; Sowiak, Małgorzata; Kozajda, Anna; Cyprowski, Marcin; Irena, Szadkowska-Stańczyk

    2012-01-01

    Indoor air is contaminated with microorganisms coming from both the atmospheric air and sources present in premises. The aim of this study was to analyze the concentrations of biological agents in office buildings, dependending on ventilation/air conditioning system and season. The study covered office buildings (different in the system of ventila-tion/air conditioning). Air samples for assessing the levels of inhalable dust, endotoxins and (1-->3)-beta-D-glucans, were taken at the selected stationary points of each building during summer and winter. The air was sampled for 6 h, using portable sets consisting of the GilAir 5 pump and the head filled with a filter of fiber glass. The samples for the presence of airborne bacteria and fungi were collected twice during the day using the impaction method. Average concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans in office premises were 0.09 mg/m3, 6.00 x 10(2) cfu/m3, 4.59 x 10(1) cfu/m3, 0.42 ng/m3 and 3.91 ng/m3, respectively. Higher concentrations of the investigated agents were found in summer. In premises with air conditioning concentrations of airborne fungi, (1-->3)-beta-D-glucans and inhalable dust were significantly lower in winter. In summer the trend was reverse except for (1-->3)-beta-D-glucans. Concentrations of biological agents were affected by the season and the presence of air conditioning. Concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans, observed inside the office buildings, were significantly higher in summer than in winter. The presence of the air conditioning system modified in various ways the levels of biological agents. Its influence was greater on the concentration of fungi and (1-->3)-beta-D-glucans than on that of bacteria and endotoxins.

  11. Investigation into the effect of closed-system suctioning on the frequency of pediatric ventilator-associated pneumonia in a developing country.

    Science.gov (United States)

    Morrow, Brenda M; Mowzer, Rukaiya; Pitcher, Richard; Argent, Andrew C

    2012-01-01

    To investigate the effect of closed-system vs. open endotracheal suctioning on the frequency of ventilator-associated pneumonia and outcome in a pediatric intensive care unit in a developing country. Prospective observational and nonrandomized controlled clinical study. A 20-bed pediatric intensive care unit in a tertiary pediatric hospital. Infants and children mechanically ventilated for >24 hrs. : Pediatric intensive care unit suctioning systems were alternated monthly. An 8-month interim analysis was planned with a priori efficacy and futility study termination boundaries set at p .52, respectively. Demographic, clinical, and laboratory data were prospectively recorded. Ventilator-associated pneumonia was diagnosed using the Clinical Pulmonary Infection Score, and the results were confirmed retrospectively using Centers for Disease Control criteria. A total of 250 patients (median [interquartile range] age of 3.8 [1.2-15.0] months) in 263 pediatric intensive care unit admissions were included. Fifty-nine admissions developed ventilator-associated pneumonia, with a calculated rate of 45.1 infections per 1000 ventilated days. There was no difference in characteristics or outcome between patients on closed-system suctioning (n = 83) and those on open endotracheal suctioning (n = 180). The frequencies of ventilator-associated pneumonia for patients on closed-system suctioning and open endotracheal suctioning were 20.5% and 23.3%, respectively (p = .6), reaching the a priori set limit of futility. Patients who developed ventilator-associated pneumonia spent a median (interquartile range) of 22 (13-37) and 11 (8-16) days in the hospital and pediatric intensive care unit, respectively, compared to 14.5 (10-24) and 6 (4-8) days for those without ventilator-associated pneumonia (p < .001). A 22% proportion of patients who developed ventilator-associated pneumonia died compared to 11.3% of those without ventilator-associated pneumonia (p = .03). Risk factors for

  12. A Bayesian decision-support system for diagnosing ventilator-associated pneumonia.

    Science.gov (United States)

    Schurink, Carolina A M; Visscher, Stefan; Lucas, Peter J F; van Leeuwen, Henk J; Buskens, Erik; Hoff, Reinier G; Hoepelman, Andy I M; Bonten, Marc J M

    2007-08-01

    To determine the diagnostic performance of a Bayesian Decision-Support System (BDSS) for ventilator-associated pneumonia (VAP). A previously developed BDSS, automatically obtaining patient data from patient information systems, provides likelihood predictions of VAP. In a prospectively studied cohort of 872 ICU patients, VAP was diagnosed by two infectious-disease specialists using a decision tree (reference diagnosis). After internal validation daily BDSS predictions were compared with the reference diagnosis. For data analysis two approaches were pursued: using BDSS predictions (a) for all 9422 patient days, and (b) only for the 238 days with presumed respiratory tract infections (RTI) according to the responsible physicians. 157 (66%) of 238 days with presumed RTI fulfilled criteria for VAP. In approach (a), median daily BDSS likelihood predictions for days with and without VAP were 77% [Interquartile range (IQR) = 56-91%] and 14% [IQR 5-42%, p BDSS cut-off point for VAP was 46%, and with this cut-off point positive predictive value (PPV) and negative predictive value (NPV) were 6.1 and 99.6%, respectively [AUC = 0.857 (95% CI 0.827-0.888)]. In approach (b), optimal cut-off for VAP was 78%, and with this cut-off point PPV and NPV were 86 and 66%, respectively [AUC = 0.846 (95% CI 0.794-0.899)]. As compared with the reference diagnosis, the BDSS had good test characteristics for diagnosing VAP, and might become a useful tool for assisting ICU physicians, both for routinely daily assessment and in patients clinically suspected of having VAP. Empirical validation of its performance is now warranted.

  13. DNA accumulation on ventilation system filters in university buildings in Singapore.

    Directory of Open Access Journals (Sweden)

    Irvan Luhung

    Full Text Available Biological particles deposit on air handling system filters as they process air. This study reports and interprets abundance and diversity information regarding biomass accumulation on ordinarily used filters acquired from several locations in a university environment.DNA-based analysis was applied both to quantify (via DNA fluorometry and qPCR and to characterize (via high-throughput sequencing the microbial material on filters, which mainly processed recirculated indoor air. Results were interpreted in relation to building occupancy and ventilation system operational parameters.Based on accumulated biomass, average DNA concentrations per AHU filter surface area across nine indoor locations after twelve weeks of filter use were in the respective ranges 1.1 to 41 ng per cm2 for total DNA, 0.02 to 3.3 ng per cm2 for bacterial DNA and 0.2 to 2.0 ng DNA per cm2 for fungal DNA. The most abundant genera detected on the AHU filter samples were Clostridium, Streptophyta, Bacillus, Acinetobacter and Ktedonobacter for bacteria and Aspergillus, Cladosporium, Nigrospora, Rigidoporus and Lentinus for fungi. Conditional indoor airborne DNA concentrations (median (range were estimated to be 13 (2.6-107 pg/m3 for total DNA, 0.4 (0.05-8.4 pg/m3 for bacterial DNA and 2.3 (1.0-5.1 pg/m3 for fungal DNA.Conditional airborne concentrations and the relative abundances of selected groups of genera correlate well with occupancy level. Bacterial DNA was found to be more responsive than fungal DNA to differences in occupancy level and indoor environmental conditions.

  14. COST EFFECTIVE VOC EMISSION CONTROL STARTEGIES FOR MILITARY, AEROSPACE,AND INDUSTRIAL PAINT SPRAY BOOTH OPERATIONS: COMBINING IMPROVED VENTILATION SYSTEMS WITH INNOVATIVE, LOW COST EMISSION CONTROL TECHNOLOGIES

    Science.gov (United States)

    The paper describes a full-scale demonstration program in which several paint booths were modified for recirculation ventilation; the booth exhaust streams are vented to an innovative volatile organic compound (VOC) emission control system having extremely low operating costs. ...

  15. 46 CFR 32.60-20 - Pumprooms on tank vessels carrying Grade A, B, C, D and/or E liquid cargo-TB/ALL.

    Science.gov (United States)

    2010-10-01

    .... Ventilation from the weather deck shall be provided. Power supply ventilation may be fitted in lieu of natural... not exceed 500 °F. (b) Ventilation for pumprooms on tank vessels the construction or conversion of... with power ventilation. Pumprooms equipped with power ventilation shall have the ventilation outlets...

  16. Assessment of materials technology of pressure vessels and piping for coal conversion systems

    Energy Technology Data Exchange (ETDEWEB)

    Canonico, D.A.; Cooper, R.H.; Foster, B.E.; McClung, R.W.; Nanstad, R.K.; Robinson, G.C.; Slaughter, G.M.

    1978-08-01

    The current technology of the materials, fabrication, and inspection of pressure vessels and piping for commercial coal conversion systems is reviewed. Comparison is made between the various codes applicable to these conversion systems. Areas of concern, such as material compatibility and fracture toughness, are cited. Recommendations are made that should increase the reliability of these components, the failure of which would result in a major outage of the plant. We believe that to date most of the current studies of various competing processes have emphasized the capital cost aspects to show potential competition with other energy sources but have not adequately examined the influence of design features on both potential maintenance and disruptive failure costs. It appears, for example, that the choice of vessel size (which is dictated by single vs multiple train process designs) has been examined primarily from the standpoint of capital costs. Maintenance, operation, relative part load capability, and relative probability of failure are unanswered questions. The materials having the most favorable mechanical properties and costs, unfortunately, are sensitive to various embrittling phenomena.

  17. Bed-integrated local exhaust ventilation system combined with local air cleaning for improved IAQ in hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Mizutani, Chiyomi

    2016-01-01

    micro-environment was exhausted. Two modes of operation were studied: 1) the exhausted polluted air was discharged out of the room and 2) the polluted air was cleaned by the ACF material installed inside the mattress and recirculated back into the room. Both modes of operation efficiently reduced......The performance of a ventilated mattress (VM) used as a bed-integrated local exhaust ventilation system combined with air cleaning fabric (acid-treated activated carbon fibre (ACF) fabric) was developed and studied. The separate and combined effect of the VM and the local air cleaning for reducing....... The patient's body was covered with either a cotton sheet or with the ACF material used as a blanket. Ammonia gas released from the patient's groins simulated the body generated bio-effluents. At the location of the groins the surface area of the VM was perforated through which the contaminated air of the bed...

  18. Lecture Notes on Mixing Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    The main task of the ventilation system or the air-conditioning system is to supply· and remove air and airborne materials and to supply or remove heat from a room. The necessary level of fresh air will be supplied to· a room by a ventilation system, and heat from equipment or solar radiation can...

  19. Descriptions and diagrams of the primary and annulus ventilation systems of the double-shell tank farms as of January 1988

    Energy Technology Data Exchange (ETDEWEB)

    Blackman, A.E.; Waters, E.D.

    1994-12-28

    This document is a compilation of information describing the ventilation systems of the Double-Shell Tank farms (214-AN, -AP, -AW, -AW, -AY, -AZ, and -SY). A general description of the primary tank and annulus ventilation systems is given along with specific information on the high efficiency particulate air (HEPA) filters, condensers, preheaters, exhaust fans, and piping. This information is considered to be current as of January 1988. 38 refs, 20 figs, 30 tabs.

  20. Atherosclerotic vessel damage in systemic lupus erythematosus and antiphospholipid syndrome in men

    Directory of Open Access Journals (Sweden)

    A. I. Iljina

    2005-01-01

    Full Text Available Objective. To study prevalence of clinical and subclinical atherosclerosis signs in men with systemic lupus erythematosus (SLE and antiphospholipid syndrome, to assess relationship between atherosclerotic vessel damage, risk factors, CRP and anti-cardiolipin antibodies (АСА Material and methods. 62 pts were included. Mean age was 35,7+11,6 years, mean disease duration - 129,3± 102 months. Traditional and related to the disease risk factors were analyzed. To reveal atherosclerotic vessel damage carotid sonographic examination was performed. Serum CRP concentration was evaluated by high sensitivity nephelometric immunoassay. IgG and IgM АСА were assessed by solid-phase immuno-enzyme assay. Results. Sonographic signs of carotid damage was revealed in 58% of pts, clinical signs of atherosclerosis - in 42%. Pts were divided into two groups according to intima-media complex thickness (IMCT. Group I included 36 pts with atherosclerotic vessel damage signs (IMCT?0,9 mm. Group 2-26 pts with IMCT<0,9 mm. Mean age at the examination, age of disease onset, disease duration, smoking frequency damage index in group I pts were higher than in group 2 pts. Mean CRP concentration in atherosclerosis group was significantly higher than in group 2 (p=0,007. 19 pts had APS signs. 43 pts did not. CRP level significantly correlated with IMCT in SLE pts with and without APS (p<0,05. Pts with atherosclerosis had higher IgG АСА level though the differences were not statistically significant. Conclusion. Men with SLE with or without APS have high risk of atherosclerosis development. CRP elevation is associated with IMCT increase.

  1. Radiological and toxicological analyses of tank 241-AY-102 and tank 241-C-106 ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Himes, D.A.

    1998-08-11

    The high heat content solids contained in Tank 241-C-106 are to be removed and transferred to Tank 241-AY-102 by sluicing operations, to be authorized under project W320. While sluicing operations are underway, the state of these tanks will be transformed from unagitated to agitated. This means that the partition fraction which describes the aerosol content of the head space will increase from IE-10 to IE-8 (see WHC-SD-WM-CN062, Rev. 2 for discussion of partition fractions). The head spare will become much more loaded with suspended material. Furthermore, the nature of this suspended material can change significantly: sluicing could bring up radioactive solids which normally would lay under many meters of liquid supernate. It is assumed that the headspace and filter aerosols in Tank 241-AY-102 are a 90/10 liquid/solid split. It is further assumed that the sluicing line, the headspace in Tank 241-C-106, and the filters on Tank 241-C-106 contain aerosols which are a 67/33 liquid/solid split. The bases of these assumptions are discussed in Section 3.0. These waste compositions (referred to as mitigated compositions) were used in Attachments 1 through 4 to calculate survey meter exposure rates per liter of inventory in the various system components. Three accident scenarios are evaluated: a high temperature event which melts or burns the HEPA filters and causes releases from other system components; an overpressure event which crushes and blows out the HEPA filters and causes releases from other system components; and an unfiltered release of tank headspace air. The initiating event for the high temperature release is a fire caused by a heater malfunction inside the exhaust dust or a fire outside the duct. The initiating event for the overpressure event could be a steam bump which over pressurizes the tank and leads to a blowout of the HEPA filters in the ventilation system. The catastrophic destruction of the HEPA filters would release a fraction of the accumulated

  2. Mechanical Ventilation

    Science.gov (United States)

    ... cared for in a hospital’s intensive care unit (ICU). People who need a ventilator for a longer time may be in a regular unit of a hospital, a rehabilitation facility, or cared for at home. Why are ...

  3. Development of Integrated Regulatory Aging Management System related to Reactor Vessel Internals

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Hanok; Park, Jeongsoon; Kim, Seonjae; Jhung, Myungjo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-05-15

    The primary function of the reactor vessel internals (RVIs) is to support the core, the control rod assemblies, the core support structure and the reactor pressure vessel (RPV) surveillance capsules. The RVIs have the additional function to direct the flow of the reactor coolant and provide shielding for the RPV. Ageing mechanisms are specific processes that gradually change characteristics of a component with time and use. According to the Generic Aging Lessons Learned (GALL) report, aging mechanisms, such as fatigue, embrittlement, corrosion, wear, radiation induced creep, relaxation and swelling, is related to RVIs. Establishing that effects of aging degradation in RVIs are adequately managed is vital for assuring continued functionality of RVIs. To achieve this goal, it is necessary to develop the regulatory standard as well as generic inspection and evaluation guideline for RVIs. In this paper, the Integrated Regulatory Aging Management System (IR-Aging), which efficiently manages key data necessary to the development of regulatory standards and assists effective evaluation of RVIs, is proposed. By using the proposed system, experts in different fields can co-operate to resolve safety issues and all users can share information and create valuable knowledge-base. In this paper, the Integrated Regulatory Aging Management System (IR-Aging) is proposed in order to manage data necessary to the development of regulatory standards and assists effective evaluation of RVIs. The proposed system provides various documents, such as US NRC and domestic regulatory documents, licensee's documents submitted to a regulatory body, and research documents. By using the proposed system, experts in different fields can co-operate to resolve safety issues and all users can share information and create valuable knowledge-base.

  4. Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system - a human response study in hot and humid climate

    DEFF Research Database (Denmark)

    Bin, Yang; Sekhar, S.C.; Melikov, Arsen Krikor

    2010-01-01

    The benefits of thermal comfort and indoor air quality with personalized ventilation (PV) systems have been demonstrated in recent studies. One of the barriers for wide spread acceptance by architects and HVAC designers has been attributed to challenges and constraints faced in the integration...

  5. Improving the energy and IAQ performance of ventilation systems in Dutch dwellings

    NARCIS (Netherlands)

    Holsteijn, R.C.A. van; Li, W.L.; Valk, H.J.J.; Kornaat, W.

    2016-01-01

    MONICAIR - MONItoring & Control of Air quality in Individual Rooms - is a pre-competitive field research project of a broad consortium of Dutch ventilation unit manufacturers and research institutes, supported by the Dutch government. The first aim of the project is to investigate and compare the

  6. A step towards seascape scale conservation: using vessel monitoring systems (VMS to map fishing activity.

    Directory of Open Access Journals (Sweden)

    Matthew J Witt

    Full Text Available BACKGROUND: Conservation of marine ecosystems will require a holistic understanding of fisheries with concurrent spatial patterns of biodiversity. METHODOLOGY/PRINCIPAL FINDINGS: Using data from the UK Government Vessel Monitoring System (VMS deployed on UK-registered large fishing vessels we investigate patterns of fisheries activity on annual and seasonal scales. Analysis of VMS data shows that regions of the UK European continental shelf (i.e. Western Channel and Celtic Sea, Northern North Sea and the Goban Spur receive consistently greater fisheries pressure than the rest of the UK continental shelf fishing zone. CONCLUSIONS/SIGNIFICANCE: VMS provides a unique and independent method from which to derive patterns of spatially and temporally explicit fisheries activity. Such information may feed into ecosystem management plans seeking to achieve sustainable fisheries while minimising putative risk to non-target species (e.g. cetaceans, seabirds and elasmobranchs and habitats of conservation concern. With multilateral collaboration VMS technologies may offer an important solution to quantifying and managing ecosystem disturbance, particularly on the high-seas.

  7. Efficiency Analysis of Additions of Ice Flake in Cargo Hold Cooling System of Fishing Vessel

    Directory of Open Access Journals (Sweden)

    Amiadji Amiadji

    2017-06-01

    Full Text Available As a maritime nation, the majority of people's livelihood in Indonesia coast is as a fishermen. The process of preserving fish after being caught will determine how good the product quality. One of process on preserving fish that can be done is to perform the cooling process using a cooling machine on board. Refrigeration system certainly requires high electrical power consumption. That high power usage can be reduced as much as possible, one of which is to add chopped ice (ice flake on a fishing boat cargo space. So that the load for cooling can be reduced.The purpose of this thesis is to find out how the influence of the addition of ice flake on cooling load in the cargo hold of fishing vessels, and to know how much power is used when the cooling machine is combined with the addition of ice flake. In this analysis cooling load calculation refers to the standard ISO 7547.from the results of analysis found that the addition of ice flake on cargo space can reduce cooling load and can reduce electricity consumption day in the main vessel for the addition comparison flake ice and fish weight of 1: 1.

  8. Ventilation and air conditioning systems in maritime productions units; Panorama dos sistemas de VAC em unidades maritimas de producao

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, Fernando Pedrosa; Sztajnbok, Ernani Luis [PETROBRAS, Rio de Janeiro, RJ (Brazil); Padua, Carlos Eduardo Dantas de; Passos, Alfredo Silveira [DUOVAC Engenharia Ltda. (Brazil)

    2004-07-01

    In an Offshore Stationary Production Unit (SPU), the adequate project of the Ventilation and Air Conditioning (VAC) System is not only a thermal comfort requirement but part of the essential safety services of the installation and complement for area classification requirements associated with electrical equipment. The VAC installations are sometimes the object of complaints by onboard team. Problems such as unsatisfactory system performance, high noise levels in the accommodation quarters, offices and other areas and the discomfort caused by unbalanced ventilation and air conditioning systems, are some of the most frequent complaints. Air Conditioning systems are classified as Direct and Indirect Expansion. Decentralized systems with Indirect Expansion has been adopted in PETROBRAS projects. This conception is not used in VAC Systems for platforms installed in North Sea, where the use of Centralized Systems with Direct Expansion are more common. The objective of this work is to compare the VAC conception projects, analyzing their advantages and disadvantages . The evaluation of VAC System in PETROBRAS project, and their steps in SPU development, is also scope of this paper. (author)

  9. Role of ventilation systems in the prevention of hospital infection; Innai kansen boshi ni okeru kanki system no yakuwari

    Energy Technology Data Exchange (ETDEWEB)

    Ayliffe, G.

    1996-05-05

    This paper investigates and considers the actual state of hospital infection. The 80% or more of surgical wound infection is self-infection, for which the factor is the microorganisms that exist in a surgical wound at the completion of an operation. Airborne infection is generally due to staphylococcus aureus. There rarely is a bacteria carrier, and the germ is dispersed from him in some instances. Staphylococcus epidermis sticks to prosthesis, propagates and causes wound infection in rare occasions. Clostridium perfringens and escherichia coli also sometimes cause self-infection from wound. An ordinary plenum ventilation system is less effective for the prevention of wound infection. A remarkable example for reduction in infection is the employment of an ultra clean air system in joint replacement operations, showing reduction in joint septicemic infection from 1.5 to 0.3%. A vertical air flow system may be effectively employed in an operation room for the purpose of improving the air stream. No interrelation exists between the total number of indoor bacteria and infection without staphylococcus aureus. A person infected by methicillin-resistant staphylococcus has to be isolated into a unit. 13 refs., 1 fig., 1 tab.

  10. Variable Ventilation Improved Respiratory System Mechanics and Ameliorated Pulmonary Damage in a Rat Model of Lung Ischemia-Reperfusion

    Directory of Open Access Journals (Sweden)

    Patricia R. M. Rocco

    2017-05-01

    Full Text Available Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1 ischemia-reperfusion (IR, in which the left pulmonary hilum was completely occluded and released after 30 min; and (2 Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured and right (contralateral lungs from 6 animals per group were removed, and served as non-ventilated group (NV for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV (n = 6/group [tidal volume (VT = 6 mL/kg, positive end-expiratory pressure (PEEP = 2 cmH2O, fraction of inspired oxygen (FiO2 = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated VT values (n = 1200; mean VT = 6 mL/kg, with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final, respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH20/ml and 2.0 ± 0.8 cmH20/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9–33.1] and VV 5.4% [3.1–8.8], p = 0.04, respectively. In left lungs of IR animals, VCV increased the expression of interleukin-6 and intercellular

  11. Variable Ventilation Improved Respiratory System Mechanics and Ameliorated Pulmonary Damage in a Rat Model of Lung Ischemia-Reperfusion.

    Science.gov (United States)

    Soluri-Martins, André; Moraes, Lillian; Santos, Raquel S; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Pelosi, Paolo; Silva, Pedro L; de Abreu, Marcelo Gama; Rocco, Patricia R M

    2017-01-01

    Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV) has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV) in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1) ischemia-reperfusion (IR), in which the left pulmonary hilum was completely occluded and released after 30 min; and (2) Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured) and right (contralateral) lungs from 6 animals per group were removed, and served as non-ventilated group (NV) for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV (n = 6/group) [tidal volume (VT) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 2 cmH2O, fraction of inspired oxygen (FiO2) = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated VT values (n = 1200; mean VT = 6 mL/kg), with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final), respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH20/ml and 2.0 ± 0.8 cmH20/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9-33.1] and VV 5.4% [3.1-8.8], p = 0.04, respectively). In left lungs of IR animals, VCV increased the expression of interleukin-6 and intercellular adhesion

  12. "Fighting the system": Families caring for ventilator-dependent children and adults with complex health care needs at home

    Directory of Open Access Journals (Sweden)

    Nielsen Erik W

    2011-07-01

    Full Text Available Abstract Background An increasing number of individuals with complex health care needs now receive life-long and life-prolonging ventilatory support at home. Family members often take on the role of primary caregivers. The aim of this study was to explore the experiences of families giving advanced care to family members dependent on home mechanical ventilation. Methods Using qualitative research methods, a Grounded Theory influenced approach was used to explore the families' experiences. A total of 15 family members with 11 ventilator-dependent individuals (three children and eight adults were recruited for 10 in-depth interviews. Results The core category, "fighting the system," became the central theme as family members were asked to describe their experiences. In addition, we identified three subcategories, "lack of competence and continuity", "being indispensable" and "worth fighting for". This study revealed no major differences in the families' experiences that were dependent on whether the ventilator-dependent individual was a child or an adult. Conclusions These findings show that there is a large gap between family members' expectations and what the community health care services are able to provide, even when almost unlimited resources are available. A number of measures are needed to reduce the burden on these family members and to make hospital care at home possible. In the future, the gap between what the health care can potentially provide and what they can provide in real life will rapidly increase. New proposals to limit the extremely costly provision of home mechanical ventilation in Norway will trigger new ethical dilemmas that should be studied further.

  13. "Fighting the system": families caring for ventilator-dependent children and adults with complex health care needs at home.

    Science.gov (United States)

    Dybwik, Knut; Tollåli, Terje; Nielsen, Erik W; Brinchmann, Berit S

    2011-07-04

    An increasing number of individuals with complex health care needs now receive life-long and life-prolonging ventilatory support at home. Family members often take on the role of primary caregivers. The aim of this study was to explore the experiences of families giving advanced care to family members dependent on home mechanical ventilation. Using qualitative research methods, a Grounded Theory influenced approach was used to explore the families' experiences. A total of 15 family members with 11 ventilator-dependent individuals (three children and eight adults) were recruited for 10 in-depth interviews. The core category, "fighting the system," became the central theme as family members were asked to describe their experiences. In addition, we identified three subcategories, "lack of competence and continuity", "being indispensable" and "worth fighting for". This study revealed no major differences in the families' experiences that were dependent on whether the ventilator-dependent individual was a child or an adult. These findings show that there is a large gap between family members' expectations and what the community health care services are able to provide, even when almost unlimited resources are available. A number of measures are needed to reduce the burden on these family members and to make hospital care at home possible. In the future, the gap between what the health care can potentially provide and what they can provide in real life will rapidly increase. New proposals to limit the extremely costly provision of home mechanical ventilation in Norway will trigger new ethical dilemmas that should be studied further.

  14. Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Black, Douglas R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-12-01

    This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration produced indoor PM2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection whereas supply MERV16 filtration reduced PM2.55 by 97-98% relative to outdoors. Supply filtration systems used little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 filters in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM2.5. Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.

  15. Mechanical ventilation in neurosurgical patients

    OpenAIRE

    Keshav Goyal; Ranadhir Mitra; Shweta Kedia

    2013-01-01

    Mechanical ventilation significantly affects cerebral oxygenation and cerebral blood flow through changes in arterial carbon dioxide levels. Neurosurgical patients might require mechanical ventilation for correction and maintenance of changes in the pulmonary system that occur either due to neurosurgical pathology or following surgery during the acute phase. This review discusses the basics of mechanical ventilation relevant to the neurosurgeon in the day-to-day management of neurosurgical pa...

  16. Mechanical ventilation in neurosurgical patients

    Directory of Open Access Journals (Sweden)

    Keshav Goyal

    2013-01-01

    Full Text Available Mechanical ventilation significantly affects cerebral oxygenation and cerebral blood flow through changes in arterial carbon dioxide levels. Neurosurgical patients might require mechanical ventilation for correction and maintenance of changes in the pulmonary system that occur either due to neurosurgical pathology or following surgery during the acute phase. This review discusses the basics of mechanical ventilation relevant to the neurosurgeon in the day-to-day management of neurosurgical patient requiring artificial support of the respiration.

  17. Comparison of a Constant Air Volume (CAV) and a Demand Controlled Ventilation (DCV) System in a Residential Building

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Topp, Claus

    2008-01-01

    hygroscopic properties on indoor climate and energy consumption was investigated for the two systems. Dynamic simulations of the studio apartment were carried out in the program WUFI+ with weather data from Copenhagen including outside temperature end relative humidity. For the non-hygroscopic case...... it was found that the energy consumption for heating and operating the ventilation system could be reduced by respectively 8.0% and 10.6 % in the case of DCV without negative impact on the indoor climate. Including the hygroscopic properties of the materials resulted in a reduction of the energy consumption...

  18. Ventilation distribution and small airway function in patients with systemic sclerosis

    Directory of Open Access Journals (Sweden)

    B.R.A. Silva

    2017-05-01

    Full Text Available Background: Despite the importance of traditional pulmonary function tests (PFTs in managing systemic sclerosis (SSc, many patients with pulmonary disease diagnosed by computed tomography (CT present with normal PFTs. Objective: To evaluate the efficacy of the nitrogen single-breath washout (N2SBW test in diagnosing SSc and to correlate N2SBW parameters with the PFT indexes used in the follow-up of these patients, clinical data, and CT findings. Methods: Cross-sectional study in which 52 consecutive SSc patients were subjected to spirometry, body plethysmography, analysis of the diffusing capacity for carbon monoxide (DLCO, analysis of respiratory muscle strength, N2SBW testing, and CT analysis. Results: Twenty-eight patients had a forced vital capacity (FVC that was 120% of the predicted value, while 15 patients had a closing volume/vital capacity (CV/VC that was >120% of the predicted value. A significant difference in Phase III slopeN2SBW was observed when the patients with predominant traction bronchiectasis and honeycombing were compared to the patients with other CT patterns (p < 0.0001. The Phase III slopeN2SBW was correlated with FVC (rs = −0.845, p < 0.0001 and DLCO (rs = −0.600, p < 0.0001, and the CV/VC was correlated with FVC (rs = −0.460, p = 0.0006 and residual volume/total lung capacity (rs = 0.328, p = 0.017. Conclusion: Ventilation heterogeneity is a frequent finding in SSc patients that is associated with restrictive damage, changes in pulmonary diffusion, and CT patterns. In addition, approximately one-third of the patients presented with findings that were compatible with small airway disease. Keywords: Systemic sclerosis, Respiratory function tests, Nitrogen single-breath washout test

  19. Software-assisted live visualization system for subjacent blood vessels in endonasal endoscopic approaches

    Science.gov (United States)

    Lempe, B.; Taudt, Ch.; Maschke, R.; Gruening, J.; Ernstberger, M.; Basan, F.; Baselt, T.; Grunert, R.; Hartmann, P.

    2013-02-01

    Minimal invasive surgery methods have received growing attention in recent years. In vital important areas, it is crucial for the surgeon to have a precise knowledge of the tissue structure. Especially the visualization of arteries is desirable, as the destruction of the same can be lethal to the patient. In order to meet this requirement, the study presents a novel assistance system for endoscopic surgery. While state-of-the art systems rely on pre-operational data like computer-tomographic maps and require the use of radiation, the goal of the presented approach is to provide the clarification of subjacent blood vessels on live images of the endoscope camera system. Based on the transmission and reflection spectra of various human tissues, a prototype system with a NIR illumination unit working at 808 nm was established. Several image filtering, processing and enhancement techniques have been investigated and evaluated on the raw pictures in order to obtain high quality results. The most important were increasing contrast and thresholding by difference of Gaussian method. Based on that, it is possible to rectify a fragmented artery pattern and extract geometrical information about the structure in terms of position and orientation. By superposing the original image and the extracted segment, the surgeon is assisted with valuable live pictures of the region of interest. The whole system has been tested on a laboratory scale. An outlook on the integration of such a system in a clinical environment and obvious benefits are discussed.

  20. Application of novel linear active disturbance rejection control in dynamic positioning control system of vessels

    Directory of Open Access Journals (Sweden)

    JIN Yue

    2017-01-01

    Full Text Available Aiming at the problem in which a vessel's dynamic positioning system can control it at an expected position,a novel linear active disturbance rejection controller is designed to solve the problem of poor dynamic performance due to the omission of a tracking differentiator. Based on the advantages of linear and nonlinear tracking differentiators,an improved tracking differentiator is designed which can track the differential signal and degrade the effects of noise; it constitutes a novel Linear Active Disturbance Rejection Controller(LADRC. The simulation results show that the novel LADRC based on the improved tracking differentiator has strong robustness,high control accuracy and good dynamic performance compared with the traditional LADRC.

  1. AIS as key component in modern vessel traffic management and information systems

    Energy Technology Data Exchange (ETDEWEB)

    Lamers, W. [DaimlerChrysler Aerospace AG (DASA), Ulm (Germany)

    1999-07-01

    The objective of this paper is to provide information in respect to universal shipborne identification system (UAIS) as main sensor in various vessel traffic applications. The presented paper will give general information concerning AIS functionality and the standardisation process. Based on experience from recent projects and various IALA working group activities, a typical future VTMIS architectures is also presented being based on AIS as key sensor. The required key performance of AIS associated with the HW components will be described. The results from European technology study Indris are presented and discussed. Finally, a summary and conclusion from the presented material will complete the technical paper. The elaboration of this presentation has been carried out as a joint task between Mr. Andre van Berg, MDS Suedafrika und Mr. Walter Lamers, DASA Ulm. (orig.)

  2. Mooring System Diagnosis and Structural Reliability Control for Position Moored Vessels

    DEFF Research Database (Denmark)

    Fang, Shaoji; Blanke, Mogens; Leira, Bernt J.

    2015-01-01

    Early diagnosis and fault-tolerant control are essential for safe operation of oating platforms where mooring systems maintain vessel position and must withstand environmental loads. This paper considers two critical faults, line breakage and loss of a buoyancy element and employs vector...... for monitoring the safety level of each mooring line and, a set-point chasing algorithm accommodates the eects of line failure, as an integral part of the reliability- based set-point chasing control algorithm. The feasibility of the diagnosis and of the fault-tolerant control strategy is veried in model basin...... statistical change detection for timely diagnosis of faults. Diagnosis design is scrutinized and a procedure is proposed based on specied false alarm probability and estimation of the distribution of the test statistics on which change detection is based. A structural reliability index is applied...

  3. Continuous on-line measurements of respiratory system, lung and chest wall mechanics during mechanic ventilation.

    Science.gov (United States)

    Kárason, S; Søndergaard, S; Lundin, S; Stenqvist, O

    2001-08-01

    We present a concept of on-line, manoeuvre-free monitoring of respiratory mechanics during dynamic conditions, displaying calculated alveolar pressure/volume curves continuously and separating lung and chest wall mechanics. Prospective observational study. Intensive care unit of a university hospital. Ten ventilator-treated patients with acute lung injury. Different positive end-expiratory pressure (PEEP) and tidal volumes, low flow inflation. Previously validated methods were used to present a single-value dynostatic compliance for the whole breath and a dynostatic volume-dependent initial, middle and final compliance within the breath. A high individual variation of respiratory mechanics was observed. Reproducibility of repeated measurements was satisfactory (coefficients of variations for dynostatic volume-dependent compliance: mechanics during ongoing ventilator treatment.

  4. The School Advanced Ventilation Engineering Software (SAVES)

    Science.gov (United States)

    The School Advanced Ventilation Engineering Software (SAVES) package is a tool to help school designers assess the potential financial payback and indoor humidity control benefits of Energy Recovery Ventilation (ERV) systems for school applications.

  5. Mechanisms of natural ventilation in livestock buildings

    DEFF Research Database (Denmark)

    Rong, Li; Bjerg, Bjarne Schmidt; Batzanas, Thomas

    2016-01-01

    Studies on the mechanisms of natural ventilation in livestock buildings are reviewed and influences on discharge and pressure coefficients are discussed. Compared to studies conducted on buildings for human occupation and industrial buildings which focus on thermal comfort, ventilation systems...

  6. Autonomic adjusting of activity of cardio-vessel system of girls of the prepubescence period, engaged in dancing aerobic

    Directory of Open Access Journals (Sweden)

    Romanchuk А.P.

    2010-03-01

    Full Text Available The vegetative adjusting of activity of the cardio-vessel system of girls is investigational. In an experiment took part girls of 9-12 years old. A type of sport is a dancing aerobics. The indexes of general power of spectrum of variability of cardiac rhythm are presented, systole and diastole arteriotony. Motion of the adaptation re-erecting is appraised under influence of the physical loadings in the conditions of current and operative control. Certain change activity and tone of vegetative influences on the cardio-vessel system. They determine the features of the further adaptation re-erecting in an organism.

  7. An ontology-based consultation system to support medical care on board seagoing vessels.

    Science.gov (United States)

    Carletti, Gabrielle; Giuliodori, Paolo; Di Pietri, Vincenzo; Peretti, Alessandro; Amenta, Francesco

    2016-01-01

    A realistic possibility to obtain medical care for patients located in remote sites such as seagoing vessels, in which health professionals are not available, is to contact a doctor via telecommunication systems. In general, the medical knowledge of who on board ships is in charge of medical care is quite limited and therefore, in a first level telemedical consultation, the flow of information should be correct and its efficiency should be maximised. This paper describes an application conceived to improve requests of medical assistance from sailing ships. The ultimate objective of this system is a) to standardise as much as possible the requests of medical advice at a distance, b) to overcome language barriers and jammed-related troubles that could make difficult or not understandable a telephone conversation. The application is based on a software engine extracting data from an ontological knowledgebase built ad hoc using Protégé. Compared to the conventional consultation systems based on telephone and e-mail, the proposed device is more accurate and complete in terms of information contained in the request of assistance. Moreover, data received by the medical centre can be more easily managed, as they can be standardised. The system described here allows people responsible of medical care on board ships to forward detailed requests of assistance containing symptom-guided information on patient clinical conditions. This may represent an innovative tool for medical consultations at distance allowing the remote centre to provide more precise and quicker medical advice.

  8. Ventilation with heat recovery

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    This paper presents the experiences from the use of ventilation with heat recovery in several experimental single-family houses developed and built within the last four years to meet the new Danish energy requirements of 2005. Included are descriptions of the ventilation system components...... and the main functional demands as well as measurements of the thermal efficiency, electricity consumptions and building air tightness. The paper addresses the aspects of minimizing the heat loss from the duct system and the heat recovery unit (when placed in an unheated attic space) in order to obtain...

  9. Thermal plumes in ventilated rooms

    DEFF Research Database (Denmark)

    Kofoed, Peter; Nielsen, Peter V.

    1990-01-01

    The design of a displacement ventilation system involves determination of the flow rate in the thermal plumes. The flow rate in the plumes and the vertical temperature gradient influence each other, and they are influenced by many factors. This paper shows some descriptions of these effects. Free...... to be the only possible approach to obtain the volume flow in: thermal plumes in ventilated rooms....

  10. Low-Flow Extracorporeal Carbon Dioxide Removal Using the Hemolung Respiratory Dialysis System(®) to Facilitate Lung-Protective Mechanical Ventilation in Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Akkanti, Bindu; Rajagopal, Keshava; Patel, Kirti P; Aravind, Sangeeta; Nunez-Centanu, Emmanuel; Hussain, Rahat; Shabari, Farshad Raissi; Hofstetter, Wayne L; Vaporciyan, Ara A; Banjac, Igor S; Kar, Biswajit; Gregoric, Igor D; Loyalka, Pranav

    2017-06-01

    Extracorporeal carbon dioxide removal (ECCO2R) permits reductions in alveolar ventilation requirements that the lungs would otherwise have to provide. This concept was applied to a case of hypercapnia refractory to high-level invasive mechanical ventilator support. We present a case of an 18-year-old man who developed post-pneumonectomy acute respiratory distress syndrome (ARDS) after resection of a mediastinal germ cell tumor involving the left lung hilum. Hypercapnia and hypoxemia persisted despite ventilator support even at traumatic levels. ECCO2R using a miniaturized system was instituted and provided effective carbon dioxide elimination. This facilitated establishment of lung-protective ventilator settings and lung function recovery. Extracorporeal lung support increasingly is being applied to treat ARDS. However, conventional extracorporeal membrane oxygenation (ECMO) generally involves using large cannulae capable of carrying high flow rates. A subset of patients with ARDS has mixed hypercapnia and hypoxemia despite high-level ventilator support. In the absence of profound hypoxemia, ECCO2R may be used to reduce ventilator support requirements to lung-protective levels, while avoiding risks associated with conventional ECMO.

  11. Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar ., S. C.; Melikov, Arsen Krikor

    2011-01-01

    A comprehensive study comprising physical measurements and human subject experiments was conducted to explore the potential for improving occupants' thermal comfort and indoor air quality (IAQ) using a personalized ventilation (PV) system combined with an under-floor air distribution(UFAD) system....... The integrated PV-UFAD system, when operated at relatively high temperature of the air supplied from the UFAD system, provided comfortable cooling of the facial region, improved inhaled air quality, and decreased the risk of "cold feet," which is often reported in rooms with UFAD alone. This article explores...... with thermal sensation at the face region. The measured inhaled air quality indices (personalized exposure effectiveness and personalized exposure index) were improved by decreasing PV supply air temperature. The perceived inhaled air freshness increased with the decrease of the inhaled air temperature...

  12. Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients

    OpenAIRE

    Miguel Angel Palomero-Rodríguez; Héctor Chozas de Arteaga; Yolanda Laporta Báez; Jesús de Vicente Sánchez; Pascual Sanabria Carretero; Pilar Sánchez Conde; Antonio Pérez Ferrer

    2016-01-01

    Background: Over the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants (“Mapleson D CPAP system”). The primary goal of this study was to assess the usefulness of the “Mapleson D CPAP system” for weaning of mechanical ventilation (MV) in infants who received MV over 24 h. Materials and Methods: All infants who received MV for more than 24 h in the last year were enrolled in the study. De...

  13. Fractals and fractal dimension of systems of blood vessels: An analogy between artery trees, river networks, and urban hierarchies

    CERN Document Server

    Chen, Yanguang

    2015-01-01

    An analogy between the fractal nature of networks of arteries and that of systems of rivers has been drawn in the previous works. However, the deep structure of the hierarchy of blood vessels has not yet been revealed. This paper is devoted to researching the fractals, allometric scaling, and hierarchy of blood vessels. By analogy with Horton-Strahler's laws of river composition, three exponential laws have been put forward. These exponential laws can be reconstructed and transformed into three linear scaling laws, which can be named composition laws of blood vessels network. From these linear scaling laws it follows a set of power laws, including the three-parameter Zipf's law on the rank-size distribution of blood vessel length and the allometric scaling law on the length-diameter relationship of blood vessels in different orders. The models are applied to the observed data on human beings and animals early given by other researchers, and an interesting finding is that human bodies more conform to natural r...

  14. Measurement of inner defects and out of plane deformation of pressure vessel in piping of circulation system using shearography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chan Geun; Kim, Hyun Ho; Jung, Hyun Il; Choi, Tae Ho; Jung, Hyun Chul; Kim, Kyeog Suk [Chosun University, Gwangju (Korea, Republic of)

    2014-10-15

    Wall thinning defects can occur in the pressure vessels used in a variety of industries. Such defects are related to the flow velocity. Considering the fact that such vessels constitute up to 70 or 80% of the plant structures in a power plant, it is important to measure internal defects as part of a safety evaluation. In this study, optical measurement were applied in a non-destructive evaluation using shearography to ensure the safety and improve the reliability of a power plant through the non-contact, non-destructive evaluation of pressure vessels. In order to verify whether the pressure vessels contained faults, experimental and analytical investigation were conducted to measure any internal defects and out-of-plane deformation from inner temperature changes and pressure changes in the piping of the circulation system. The most important factors in this research were the thickness, width, and length of a defect. An increase in these could confirm an increase in the deformation. Thus, internal defects in a pressure vessel were measured using shearography, which made it possible to ensure the reliability and integrity of the pipe.

  15. Hypoxic vasoconstriction of cyclostome systemic vessels: the antecedent of hypoxic pulmonary vasoconstriction?

    Science.gov (United States)

    Olson, K R; Russell, M J; Forster, M E

    2001-01-01

    Hypoxic vasoconstriction (HV) is an intrinsic response of mammalian pulmonary vascular smooth muscle (VSM). In the present study, HV was examined by myography of vessel rings from three primitive vertebrates: New Zealand hagfish (NZH), Pacific hagfish (PH), and sea lamprey (SL). Hypoxia dilated pre-gill arteries (ventral aorta, afferent branchial) from all species, whereas it contracted systemic arteries [dorsal aorta (DA), efferent branchial, celiacomesenteric]. DA HV was reproducible over several days, and it could be sustained in NZH for 8 h without adverse effects. Tension was proportional to PO(2), and half-maximal HV was obtained at PO(2) (mmHg) of 4.7 +/- 0. 2 (NZH), 0.8 +/- 0.1 (PH), and 10.7 +/- 1.9 (SL). HV did not require preconditioning (preexisting contractile stimulus) and was unaffected by elevated extracellular potassium (200 mM NZH; 80 mM SL); removal of the endothelium (NZH); or inhibitors of cyclooxygenase, lipoxygenase, cytochrome P-450 or antagonists of alpha-adrenergic, muscarinic, nicotinic, purinergic, or serotoninergic receptors. These results show that HV is an intrinsic feature of systemic VSM in cyclostomes and suggest that HV has been in the repertoire of VSM responses, since the origin of vertebrates. The exceptionally hardy HV in cyclostome DA may provide a useful model with which to examine both the phylogeny and mechanisms of this response.

  16. Aging in blood vessels. Medicinal agents FOR systemic arterial hypertension in the elderly.

    Science.gov (United States)

    Rubio-Ruiz, María Esther; Pérez-Torres, Israel; Soto, María Elena; Pastelín, Gustavo; Guarner-Lans, Verónica

    2014-11-01

    Aging impairs blood vessel function and leads to cardiovascular disease. The mechanisms underlying the age-related endothelial, smooth muscle and extracellular matrix vascular dysfunction are discussed. Vascular dysfunction is caused by: (1) Oxidative stress enhancement. (2) Reduction of nitric oxide (NO) bioavailability, by diminished NO synthesis and/or augmented NO scavenging. (3) Production of vasoconstrictor/vasodilator factor imbalances. (4) Low-grade pro-inflammatory environment. (5) Impaired angiogenesis. (6) Endothelial cell senescence. The aging process in vascular smooth muscle is characterized by: (1) Altered replicating potential. (2) Change in cellular phenotype. (3) Changes in responsiveness to contracting and relaxing mediators. (4) Changes in intracellular signaling functions. Systemic arterial hypertension is an age-dependent disorder, and almost half of the elderly human population is hypertensive. The influence of hypertension on the aging cardiovascular system has been studied in models of hypertensive rats. Treatment for hypertension is recommended in the elderly. Lifestyle modifications, natural compounds and hormone therapies are useful for initial stages and as supporting treatment with medication but evidence from clinical trials in this population is needed. Since all antihypertensive agents can lower blood pressure in the elderly, therapy should be based on its potential side effects and drug interactions. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Mine Ventilation System Variable Resistance Regulate Air Quantity Economy and Its Impacts on Artisanal Mine in Ivory Coast

    Directory of Open Access Journals (Sweden)

    Kouame Kouame Arthur Joseph

    2016-01-01

    Full Text Available The artisanal gold mining is one of the major illegal activities in Ivory Coast. Thousands of indigents and foreigners including men, women and children are involved in this dangerous activity. Contracting contagious diseases such as HIV/AIDS and multiple lung diseases are commonplace on the artisanal mining sites due to air pollution. For this reason, the differential analysis, research mine ventilation system by changing the working windage adjustment for air flow of the economy, identifies factors, obtained discriminant variable resistance air volume control economic quantitative criteria for underground actual situation of joint variable resistance method and economic variable resistance than the concept of the development of effective mine ventilation system to improve air quantity adjusting rheostat economical way. The findings of this study can help lead to better safety practices in mining in order to improve the health and safety of the miners who are involved in artisanal mining activities in Ivory Coast and other mining sites over the world.

  18. A Study on a Control Method with a Ventilation Requirement of a VAV System in Multi-Zone

    Directory of Open Access Journals (Sweden)

    Hyo-Jun Kim

    2017-11-01

    Full Text Available The objective of this study was to propose a control method with a ventilation requirement of variable air volume (VAV system in multi-zone. In order to control the VAV system inmulti-zone, it is essential to control the terminal unit installed in each zone. A VAV terminal unit with conventional control method using a fixed minimum air flow can cause indoor air quality (IAQ issues depending on the variation in the number of occupants. This research proposes a control method with a ventilation requirement of the VAV terminal unit and AHU inmulti-zone. The integrated control method with an air flow increase model in the VAV terminal unit, AHU, and outdoor air intake rate increase model in the AHU was based on the indoor CO2 concentration. The conventional and proposed control algorithms were compared through a TRNSYS simulation program. The proposed VAV terminal unit control method satisfies all the conditions of indoor temperature, IAQ, and stratification. An energy comparison with the conventional control method showed that the method satisfies not only the indoor thermal comfort, IAQ, and stratification issue, but also reduces the energy consumption.

  19. 78 FR 2683 - Carriage Standards for Bridge Navigational Watch Alarm Systems (BNWAS) Aboard U.S. Flagged Vessels

    Science.gov (United States)

    2013-01-14

    ... Systems (BNWAS), in accordance with the Articles of the International Convention for the Safety of Life at Sea (SOLAS) Chapter V, Regulation 19, for U.S. flagged vessels engaged on international voyages. The... effective date for the BNWAS standard, according to the terms of SOLAS Chapter V, Regulation 19, was January...

  20. CFD and Ventilation Research

    DEFF Research Database (Denmark)

    Li, Y.; Nielsen, Peter V.

    2011-01-01

    There has been a rapid growth of scientific literature on the application of computational fluid dynamics (CFD) in the research of ventilation and indoor air science. With a 1000–10,000 times increase in computer hardware capability in the past 20 years, CFD has become an integral part...... of scientific research and engineering development of complex air distribution and ventilation systems in buildings. This review discusses the major and specific challenges of CFD in terms of turbulence modelling, numerical approximation, and boundary conditions relevant to building ventilation. We emphasize...... the growing need for CFD verification and validation, suggest on-going needs for analytical and experimental methods to support the numerical solutions, and discuss the growing capacity of CFD in opening up new research areas. We suggest that CFD has not become a replacement for experiment and theoretical...

  1. Newer nonconventional modes of mechanical ventilation

    OpenAIRE

    Preet Mohinder Singh; Anuradha Borle; Anjan Trikha

    2014-01-01

    The conventional modes of ventilation suffer many limitations. Although they are popularly used and are well-understood, often they fail to match the patient-based requirements. Over the years, many small modifications in ventilators have been incorporated to improve patient outcome. The ventilators of newer generation respond to patient′s demands by additional feedback systems. In this review, we discuss the popular newer modes of ventilation that have been accepted in to clinical practice. ...

  2. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D.; Dakin, B.; German, A.

    2012-04-01

    The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  3. Ventilation for Free

    NARCIS (Netherlands)

    Scholten, R.D.; Ter Haar, J.

    2014-01-01

    This "designers' manual" is made during the TIDO-course AR0533 Innovation & Sustainability. The goal of this manual is to give a clear and simple overview of some of the possibilities for using natural ventilation in buildings. These systems are described through their formulas to give an idea of

  4. Fungal succession in an in-vessel composting system characterized using 454 pyrosequencing.

    Science.gov (United States)

    Langarica-Fuentes, Adrian; Zafar, Urooj; Heyworth, Alan; Brown, Thomas; Fox, Graeme; Robson, Geoffrey D

    2014-05-01

    Fungi are known to have an important role in the composting process as degraders of recalcitrant materials such as cellulose and lignin. Previous attempts to study the diversity and succession of fungi in compost systems have relied on the use of culture-dependent analyses and low-resolution DNA-fingerprinting techniques, lacking the necessary depth to analyse such a rich ecosystem. In this study, 454 pyrosequencing was used to characterize the fungal community composition at the different stages of an in-vessel composting process. A complex succession of fungi was revealed, with 251 fungal OTUs identified throughout the monitoring period. The Ascomycota were the dominant phylum (82.5% of all sequences recovered), followed by the Basidiomycota (10.4%) and the subphylum Mucoromycotina (4.9%). In the starting materials and early stages of the process, yeast species from the Saccharomycetales were abundant, while in latter stages and in the high temperature regions of the pile, fungi from the orders Eurotiales, Sordariales, Mucorales, Agaricales and Microascales were the most prominent. This study provides an improved understanding of the fungal diversity occurring during the composting of municipal solid waste, and this knowledge can lead to the development of more efficient composting practices and a better evaluation of the end-product quality. © 2014 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.

  5. Comparison of the electrothermal vessel-sealing system versus endoclip in laparoscopic appendectomy.

    Science.gov (United States)

    Aydogan, Fatih; Saribeyoglu, Kaya; Simsek, Osman; Salihoglu, Ziya; Carkman, Sinan; Salihoglu, Tamer; Karatas, Adem; Baca, Bilgi; Kucuk, Ozan; Yavuz, Nihat; Pekmezci, Salih

    2009-06-01

    Various techniques have been used for the division of mesoappendix, such as endoloops, endoscopic linear cutting staplers, an electrothermal vessel-sealing system (LigaSure), the Harmonic Scalpel, clips, and bipolar coagulation. In the present study, LigaSure and an endoclip were compared in laparoscopic appendectomy (LA). This study included patients who underwent LA for acute appendicitis at Istanbul University, Cerrahpasa Medical Faculty, Emergency Unit (Istanbul, Turkey) between May 2003 and April 2007. The patients were assigned to two groups according to the mesoappendix dissection device: LigaSure and endoclip groups. The main outcome measures (e.g., operating time, conversion rate, hospital stay, postoperative complications, etc.) were then compared. LA was performed in 280 patients with acute appendicitis. LigaSure and endoclips were used in 127 and 153 patients, respectively. The mean operative times were 41 and 54 minutes in the LigaSure and endoclip groups, respectively. Conversions to open rates were found to be 9.4% (12 patients) in the LigaSure and 11.1% (17 patients) in endoclip groups. No statistically significant differences regarding hospital stay or complications were found, whereas significant differences were observed in surgical time and conversion rate. The use of LigaSure facilitates the dissection of mesoappendix and shortens the operation time in LA. We believe that LigaSure is a safe, useful tool for mesoappendix dissection.

  6. Standards of the Polish Ultrasound Society. Ultrasound examination of the portal system and hepatic vessels

    Directory of Open Access Journals (Sweden)

    Robert Lechowicz

    2015-06-01

    Full Text Available Increased incidence of liver diseases, the development of liver surgery and other invasive methods for managing portal hypertension, plus an increasing number of liver transplant procedures pose more and more new challenges for ultrasonography. Ultrasonography, being an effective and clinically verifi ed modality, has been used for several decades for diagnosing diseases of the liver, its vessels and portal hypertension. It is used for both initial and specialist diagnosis (performed in reference centers. The diagnostic value of ultrasonography largely depends on the knowledge of anatomy, physiology, pathophysiology and clinical aspects as well as on the mastering of the scanning technique. In the hands of an experienced physician, it is an accurate and highly effective diagnostic tool; it is of little use otherwise. The paper presents elements of anatomy, physiology and pathophysiology which make the portal system exceptional and the knowledge of which is crucial and indispensable for a correct examination and, above all, for the correct interpretation of results. The authors also present requirements regarding the equipment. Moreover, various technical aspects of the examination are presented and the normal morphological picture and hemodynamic parameters of healthy individuals are described. The authors discuss the most common clinical situations and rare cases during ultrasound examinations. The paper is based on the experience of the author who works in the largest center of liver diseases in Poland, and on the current literature.

  7. Understanding mechanical ventilators.

    Science.gov (United States)

    Chatburn, Robert L

    2010-12-01

    The respiratory care academic community has not yet adopted a standardized system for classifying and describing modes of ventilation. As a result, there is enough confusion that patient care, clinician education and even ventilator sales are all put at risk. This article summarizes a ventilator mode taxonomy that has been extensively published over the last 15 years. Specifically, the classification system has three components: a description of the control variables within breath; a description of the sequence of mandatory and spontaneous breaths; and a specification for the targeting scheme. This three-level specification provides scalability of detail to make the mode description appropriate for the particular need. At the bedside, we need only refer to a mode briefly using the first or perhaps first and second components. To distinguish between similar modes and brand names, we would need to include all components. This taxonomy uses the equation of motion for the respiratory system as the underlying theoretical framework. All terms relevant to describing modes of mechanical ventilation are defined in an extensive appendix.

  8. Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar, S.C.; Melikov, Arsen Krikor

    2010-01-01

    The potential for improving occupants' thermal comfort with personalized ventilation (PV) system combined with under-floor air distribution (UFAD) system was explored through human response study. The hypothesis was that cold draught at feet can be reduced when relatively warm air is supplied...

  9. Installation system for ceramic self-ventilated roofs and facades called: SKIN-KER; Sistema para la instalacion de cubiertas y fachadas ceramicas autoventiladas denominado: SKIN-KER

    Energy Technology Data Exchange (ETDEWEB)

    Puerta Lopez, A.; Casanova Ramon-Borja, A.

    2012-07-01

    The Company Tejas Borja S.A.U. has been awarded by the Spanish Ceramic and Glass Society with the 2012 Golden Alfa Pize for its research in the development of an installation system that creates a self-ventilated roof with modified red body porcelain tiles, and make it extended to a ventilated facade, allowing the entire house wrap with the same quality and aesthetics. The article describes the various stages of the project design both of individual components as well as verification by simulations and lab testing of the different elements of the system and auxiliary materials involved in the installation. (Author)

  10. Heat Exchanger/Humidifier Trade Study and Conceptual Design for the Constellation Space Suit Portable Life Support System Ventilation Subsystem

    Science.gov (United States)

    Paul, Heather L.; Sompayrac, Robert; Conger, Bruce; Chamberlain, Mateo

    2009-01-01

    As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.

  11. Subjective study of thermal acceptability of novel enhanced displacement ventilation system and implication of occupants' personal control

    DEFF Research Database (Denmark)

    Sun, Weimeng; Cheong, K.W.D.; Melikov, Arsen Krikor

    2012-01-01

    A novel air distribution principle of cooler air near the floor level being propelled upward via four fans mounted at each corner of a chair was developed to enhance the performance of conventional displacement ventilation (DV) system. Experiments were conducted in a well-controlled climate chamber...... with DV and constant heat load at different supply air temperatures, namely 20, 22, and 24 °C and room air temperatures, 22, 24, and 26 °C. Subjective assessments were carried out with 32 tropically-acclimatized college students who were given the choice to adjust the fan speed. Subjects' thermal comfort...... of 22 and 24 °C when the fans were in operation. It was also found that the Whole Body Thermal Sensation (WBTS) reported by the subjects was correlated with the Local Thermal Sensation (LTS) at the waist, the arms, the calf and the feet when the novel DV system was employed. An expression which allows...

  12. GTP-W - the ventilation planning module of the GTP system; GTP-W - Das wettertechnische Planungsmodul des GTP-Systems

    Energy Technology Data Exchange (ETDEWEB)

    Langefeld, O. [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany). Inst. fuer Bergbau; Guder, R. [Deutsche Steinkohle AG, Herne (Germany); Reinartz, A. [XGraphic Ingenieurgesellschaft mbH, Aachen (Germany); Huenefeld, R. [Technische Hochschule Aachen (Germany). Lehrstuhl und Inst. fuer Bergwerks- und Huettenmaschinenkunde

    2001-11-08

    The geometrical technical planning at the DSK consists of several calculation modules and a graphic module as well as the material and information management. This has already been described in detail in this publication. The ventilation planning module (GTP-W) is a further module in this planning system. The individual partial modules Ventilation network planning with the applications 'lod roadway network/mine layout' and 'network planning', 'positioning of ventilation equipment and symbols', the 'main ventilation manual and the fire upthrust calculation' are described. Inter alia the graphic plan compilation and the differences from the predecessor system GRUBE-W are highlighted. The series of publications concerning geometrical technical planning is thus completed for the time being. The module for support technology still in the introductory and development phase will be described later. (orig.) [German] Die Geometrisch-Technische-Planung bei der DSK besteht aus einigen Berechnungs- und einem graphischen Modul sowie dem Material- und Informationsmanagement. Hierueber wurde an dieser Stelle bereits ausfuehrlich berichtet. Das wettertechnische Planungsmodul (GTP-W) ist ein weiterer Baustein in diesem Planungssystem. Beschrieben werden die einzelnen Teilmodule Wetternetzplanung mit den Anwendungen 'Streckennetz/Grubengebaeude laden' und 'Netzplanung', 'Positionierung von wettertechnischen Betriebsmitteln und Symbolen', das 'Hauptwetterbuch' und die 'Brandauftriebsberechnung'. Herausgestellt werden unter anderem die graphische Planerstellung und die Unterschiede zum Vorlaeufersystem GRUBE-W. Damit ist die Veroeffentlichungsreihe ueber die Geometrisch-Technische-Planung zunaechst beendet. Das noch in der Einfuehrungs- und Entwicklungsphase befindliche Modul zur Ausbautechnik wird spaeter vorgestellt. (orig.)

  13. Reactor moderator, pressure vessel, and heat rejection system of an open-cycle gas core nuclear rocket concept

    Science.gov (United States)

    Taylor, M. F.; Whitmarsh, C. L., Jr.; Sirocky, P. J., Jr.; Iwanczyke, L. C.

    1973-01-01

    A preliminary design study of a conceptual 6000-megawatt open-cycle gas-core nuclear rocket engine system was made. The engine has a thrust of 196,600 newtons (44,200 lb) and a specific impulse of 4400 seconds. The nuclear fuel is uranium-235 and the propellant is hydrogen. Critical fuel mass was calculated for several reactor configurations. Major components of the reactor (reflector, pressure vessel, and waste heat rejection system) were considered conceptually and were sized.

  14. Purge ventilation operability

    Energy Technology Data Exchange (ETDEWEB)

    Marella, J.R.

    1995-04-10

    A determination of minimum requirements for purge exhaust ventilation system operability has been performed. HLWE and HLW Regulatory Program personnel have evaluated the various scenarios of equipment conditions and HLWE has developed the requirements for purge exhaust systems. This report is provided to document operability requirements to assist Tank Farm personnel to determine whether a system is operable/inoperable and to define required compensatory actions.

  15. Decommissioning of Active Ventilation Systems in a Nuclear R and D Facility to Prepare for Building Demolition (Whiteshell Laboratories Decommissioning Project, Canada) - 13073

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, Brian; May, Doug; Howlett, Don; Bilinsky, Dennis [Atomic Energy of Canada Limited, Ara Mooradian Way, Pinawa, Manitoba (Canada)

    2013-07-01

    Whiteshell Laboratories (WL) is a nuclear research establishment owned by the Canadian government and operated by Atomic Energy of Canada Limited (AECL) since the early 1960's. WL is currently under a decommissioning license and the mandate is to remediate the nuclear legacy liabilities in a safe and cost effective manner. The WL Project is the first major nuclear decommissioning project in Canada. A major initiative underway is to decommission and demolish the main R and D Laboratory complex. The Building 300 R and D complex was constructed to accommodate laboratories and offices which were mainly used for research and development associated with organic-cooled reactors, nuclear fuel waste management, reactor safety, advanced fuel cycles and other applications of nuclear energy. Building 300 is a three storey structure of approximately 16,000 m{sup 2}. In order to proceed with building demolition, the contaminated systems inside the building have to be characterized, removed, and the waste managed. There is a significant focus on volume reduction of radioactive waste for the WL project. The active ventilation system is one of the significant contaminated systems in Building 300 that requires decommissioning and removal. The active ventilation system was designed to manage hazardous fumes and radioactivity from ventilation devices (e.g., fume hoods, snorkels and glove boxes) and to prevent the escape of airborne hazardous material outside of the laboratory boundary in the event of an upset condition. The system includes over 200 ventilation devices and 32 active exhaust fan units and high efficiency particulate air (HEPA) filters. The strategy to remove the ventilation system was to work from the laboratory end back to the fan/filter system. Each ventilation duct was radiologically characterized. Fogging was used to minimize loose contamination. Sections of the duct were removed by various cutting methods and bagged for temporary storage prior to disposition

  16. Concept design of the DEMO divertor cassette-to-vacuum vessel locking system adopting a systems engineering approach

    Energy Technology Data Exchange (ETDEWEB)

    Di Gironimo, G., E-mail: giuseppe.digironimo@unina.it [Università degli Studi di Napoli “Federico II”, Dipartimento di Ingegneria Industriale, Piazzale Tecchio 80, 80135 Napoli (Italy); Carfora, D. [Tampere University of Technology, Korkeakoulunkatu 6, 33720 Tampere (Finland); VTT Technical Research Centre of Finland, Tekniikankatu 1, PO Box 1300, FI-33101 Tampere (Finland); Università degli Studi di Napoli “Federico II”, Dipartimento di Ingegneria Industriale, Piazzale Tecchio 80, 80135 Napoli (Italy); Esposito, G.; Lanzotti, A.; Marzullo, D. [Università degli Studi di Napoli “Federico II”, Dipartimento di Ingegneria Industriale, Piazzale Tecchio 80, 80135 Napoli (Italy); Siuko, M. [VTT Technical Research Centre of Finland, Tekniikankatu 1, PO Box 1300, FI-33101 Tampere (Finland)

    2015-05-15

    Highlights: • An iterative and incremental design process for cassette-to-VV locking system of DEMO divertor is presented. • Three different concepts have been developed with a systematic design approach. • The final concept has been selected with Fuzzy-Analytic Hierarchy Process in virtual reality. - Abstract: This paper deals with pre-concept studies of DEMO divertor cassette-to-vacuum vessel locking system under the work program WP13-DAS-07-T06: Divertor Remote Maintenance System pre-concept study. An iterative design process, consistent with Systems Engineering guidelines and named Iterative and Participative Axiomatic Design Process (IPADeP), is used in this paper to propose new innovative solutions for divertor locking system, which can overcome the difficulties in applying the ITER principles to DEMO. The solutions conceived have been analysed from the structural point of view using the software Ansys and, eventually, evaluated using the methodology known as Fuzzy-Analytic Hierarchy Process. Due to the lack and the uncertainty of the requirements in this early conceptual design stage, the aim is to cover a first iteration of an iterative and incremental process to propose an innovative design concept to be developed in more details as the information will be completed.

  17. Comparison of vessel contrast measured with a scanning-beam digital x-ray system and an image intensifier/television system.

    Science.gov (United States)

    Speidel, M A; Wilfley, B P; Heanue, J A; Betts, T D; Van Lysel, M S

    2001-02-01

    Vessel contrast was measured in the fluoroscopic images produced by a scanning-beam digital x-ray (SBDX) system and an image intensifier/television (II/TV) based system. The SBDX system electronically scans a series of pencil x-ray beams across the patient, each of which is directed at a distant small-area detector array. The reduction in detected scatter achieved with this geometry was expected to provide an increase in image contrast. Vessel contrast was evaluated from images of a phantom containing iodinated tubes. The vessels were inserted into an acrylic stack to provide a patient-mimicking scattering medium. Vessel diameter ranged from 0.3 to 3.1 mm. Images were acquired at 100 kVp with the SBDX and II/TV systems and averaged to reduce x-ray noise. The II/TV system was operated in the 6-in. image intensifier mode with an anti-scatter grid. The increase in contrast in the SBDX images, expressed as a ratio of the measured SBDX and II/TV contrasts, ranged from 1.63 to 1.79 for individual vessels. This agreed well with a prediction of the contrast improvement ratio for this experiment, based on measurements of the scatter fraction, object-plane line spread functions, and consideration of the source spectrum and detector absorption properties. The predicted contrast improvement ratio for SBDX relative to II/TV images was 1.62 to 1.77.

  18. Short-term airing by natural ventilation

    DEFF Research Database (Denmark)

    Perino, Marco; Heiselberg, Per

    2009-01-01

    traditional mechanical ventilation components with natural ventilation devices, such as motorized windows and louvers. Among the various ventilation strategies that are currently available, buoyancy driven single-sided natural ventilation has proved to be very effective and can provide high air change rates...... that was aimed at developing and validating numerical models for the analysis of buoyancy driven single-sided natural ventilation systems. Once validated, these models can be used to optimize control strategies in order to achieve satisfactory indoor comfort conditions and IAQ.......The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. This kind of system frequently integrates...

  19. Human versus Computer Controlled Selection of Ventilator Settings: An Evaluation of Adaptive Support Ventilation and Mid-Frequency Ventilation

    Science.gov (United States)

    Mireles-Cabodevila, Eduardo; Diaz-Guzman, Enrique; Arroliga, Alejandro C.; Chatburn, Robert L.

    2012-01-01

    Background. There are modes of mechanical ventilation that can select ventilator settings with computer controlled algorithms (targeting schemes). Two examples are adaptive support ventilation (ASV) and mid-frequency ventilation (MFV). We studied how different clinician-chosen ventilator settings are from these computer algorithms under different scenarios. Methods. A survey of critical care clinicians provided reference ventilator settings for a 70 kg paralyzed patient in five clinical/physiological scenarios. The survey-derived values for minute ventilation and minute alveolar ventilation were used as goals for ASV and MFV, respectively. A lung simulator programmed with each scenario's respiratory system characteristics was ventilated using the clinician, ASV, and MFV settings. Results. Tidal volumes ranged from 6.1 to 8.3 mL/kg for the clinician, 6.7 to 11.9 mL/kg for ASV, and 3.5 to 9.9 mL/kg for MFV. Inspiratory pressures were lower for ASV and MFV. Clinician-selected tidal volumes were similar to the ASV settings for all scenarios except for asthma, in which the tidal volumes were larger for ASV and MFV. MFV delivered the same alveolar minute ventilation with higher end expiratory and lower end inspiratory volumes. Conclusions. There are differences and similarities among initial ventilator settings selected by humans and computers for various clinical scenarios. The ventilation outcomes are the result of the lung physiological characteristics and their interaction with the targeting scheme. PMID:23119152

  20. Human versus Computer Controlled Selection of Ventilator Settings: An Evaluation of Adaptive Support Ventilation and Mid-Frequency Ventilation

    Directory of Open Access Journals (Sweden)

    Eduardo Mireles-Cabodevila

    2012-01-01

    Full Text Available Background. There are modes of mechanical ventilation that can select ventilator settings with computer controlled algorithms (targeting schemes. Two examples are adaptive support ventilation (ASV and mid-frequency ventilation (MFV. We studied how different clinician-chosen ventilator settings are from these computer algorithms under different scenarios. Methods. A survey of critical care clinicians provided reference ventilator settings for a 70 kg paralyzed patient in five clinical/physiological scenarios. The survey-derived values for minute ventilation and minute alveolar ventilation were used as goals for ASV and MFV, respectively. A lung simulator programmed with each scenario’s respiratory system characteristics was ventilated using the clinician, ASV, and MFV settings. Results. Tidal volumes ranged from 6.1 to 8.3 mL/kg for the clinician, 6.7 to 11.9 mL/kg for ASV, and 3.5 to 9.9 mL/kg for MFV. Inspiratory pressures were lower for ASV and MFV. Clinician-selected tidal volumes were similar to the ASV settings for all scenarios except for asthma, in which the tidal volumes were larger for ASV and MFV. MFV delivered the same alveolar minute ventilation with higher end expiratory and lower end inspiratory volumes. Conclusions. There are differences and similarities among initial ventilator settings selected by humans and computers for various clinical scenarios. The ventilation outcomes are the result of the lung physiological characteristics and their interaction with the targeting scheme.

  1. Comparison of the Mapleson C system and adult and paediatric self-inflating bags for delivering guideline-consistent ventilation during simulated adult cardiopulmonary resuscitation.

    Science.gov (United States)

    Sherren, P B; Lewinsohn, A; Jovaisa, T; Wijayatilake, D S

    2011-07-01

    There is a discrepancy between resuscitation teaching and witnessed clinical practice. Furthermore, deleterious outcomes are associated with hyperventilation. We therefore conducted a manikin-based study of a simulated cardiac arrest to evaluate the ability of three ventilating devices to provide guideline-consistent ventilation. Mean (SD) minute ventilation was reduced with the paediatric self-inflating bag (7.0 (3.2) l.min⁻¹) compared with the Mapleson C system (9.8 (3.5) l.min⁻¹) and adult self-inflating bag (9.7 (4.2) l.min⁻¹ ; p = 0.003). Tidal volume was also lower with the paediatric self-inflating bag (391 (52) ml) compared with the others (582 (87) ml and 625 (103) ml, respectively; p < 0.001), as was peak airway pressure (14.5 (5.2) cmH₂O vs 20.7 (9.0) cmH₂O and 30.3 (11.4) cmH₂O, respectively; p < 0.001). Participants hyperventilated patients' lungs in simulated cardiac arrest with all three devices. The paediatric self-inflating bag delivered the most guideline-consistent ventilation. Its use in adult cardiopulmonary resuscitation may ensure delivery of more guideline-consistent ventilation in patients with tracheal intubation. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  2. Ligasure Vessel sealing system Tonsillectomy versus Cold Knife Tonsillectomy: A study ofefficy and Adverse effcts

    Directory of Open Access Journals (Sweden)

    Farahani F

    2017-06-01

    Full Text Available Introduction: Tonsillectomy is one of the most common procedures performed by otolaryngologists. Intraoperative bleeding is a significant problem, which requires hemostasis and causes prolonged operative time. Several different techniques are used to perform this operation. The Ligasure Vessel Sealing System (LVSST has been widely used in head and neck surgery because of its effectiveness and safety. Methods: This project was conducted at the department of otolaryngology of Besat Hospital, Hamadan, Iran. In this double-blinded clinical trial, 82 subjects, who were candidates for tonsillectomy and qualified in eligible criteria, were randomly assigned to 2 group of 41 subjects. Surgery was performed using Lvsst for one group and cold knife dissection for the other group. Measured outcomes for efficacy and adverse effect were intraoperative blood loss, operation time, post-operative pain in visual analogue scale, and post-operative bleeding for28 days after surgery. The SPSS 16 software was used for data analysis. Results: Method of LVSST was significantly better than CKT in operation time and bleeding on the first day after surgery, yet, postoperative blood loss in the first week after surgery in LVSST group was significantly higher than the CKT group. Severity of sore throat after surgery with Ligasure was higher than CKT the group, however the difference was not significant. Intraoperative bleeding in the LVSST group was significantly lower than that of the CKT group (P = 0.000. Conclusions: The results of this study showed that the prevalence of respiratory symptoms LVSST was better than CKT in intraoperative (not post-operative blood loss and operation time, yet there was no difference regarding postoperative pain. For workers with a history of allergies, this ratio is higher.

  3. Evaluation of Heating, Ventilation, and Air conditioning (HVAC System Performance in an Administrative Building in Tehran (Iran

    Directory of Open Access Journals (Sweden)

    H. Mari Oriyad

    2014-09-01

    Full Text Available Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .Material and Method: A questionnaire, developed in their research was used to assess the building occupants’ perception about the performance of HVAC system. To evaluate the performance of HVAC systems, air velocities were measured in the diffusers using a thermal anemometer. Moreover, CO2 concentration, air temperature and relative humidity were measured in the whole floors of the building. Air distribution inside the building was evaluated using smoke test. .Results: Most of the studied people complained about the direction of airflow, thermal conditions and cigarette odor. The highest level of carbon dioxide was measured at 930 ppm inside the restaurant. The maximum and minimum air temperatures and relative humidity were measured 28.3-13.8° C and 28.4-23% respectively. Smoke test showed that the air distribution/direction wasn’t suitable in one third of air diffusers. .Conclusion: Improper air distribution / direction was the main problem with the studied HVAC system which could be corrected by adjusting and balancing of the system.

  4. Displacement Ventilation

    DEFF Research Database (Denmark)

    Bjørn, Erik; Mattsson, Magnus; Sandberg, Mats

    Full-scale experiments were made in a displacement ventilated room with two breathing thermal manikins to study the effect of movements and breathing on the vertical contaminant distribution, and on the personal exposure of occupants. Concentrations were measured with tracer gas equipment...... in the room and in the inhalation of both manikins. Tracer gas was added in the heat plume above a sitting manikin, or in the exhalation through either the nose or the mouth. The other manikin moved back and forth at different speeds on a low trolley. The mentioned experimental conditions have a significant...

  5. Kitchen ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Kelso, R.M. [Univ. of Tennessee, Knoxville, TN (United States). College of Architecture; Rousseau, C. [Newcomb and Boyd Consulting Engineers, Atlanta, GA (United States)

    1995-09-01

    Kitchen ventilation is a subject that has not received the attention that has been given to more glamorous HVAC and R topics. Consequently, its theoretical and technical development has not advanced like these topics. However, a group has been working within the ASHRAE Technical Committee (TC) and Task Group (TG) framework to correct this situation. The group is TG5.KV and it achieved TG status last year after starting as an informal group and then a sub-committee of TC9.8. One of its efforts has been to write a Handbook chapter, which will appear in the 1995 ASHRAE Handbook -- Applications. This article is a survey of that chapter.

  6. Absence of Lymphatic Vessels in PCNSL May Contribute to Confinement of Tumor Cells to the Central Nervous System.

    Science.gov (United States)

    Deckert, Martina; Brunn, Anna; Montesinos-Rongen, Manuel; Siebert, Reiner

    2016-06-01

    Primary central nervous system (CNS) lymphoma (PCNSL) is a mature lymphoma of the diffuse large B-cell lymphoma (DLBCL) type confined to the CNS. Despite cytomorphological similarities between PCNSL and systemic DLBCL, molecular differences between both entities have been identified. The exclusively topographical restriction of PCNSL to the CNS is an unexplained mystery. To address the question of whether the unique lymphatic drainage system of the CNS, which differs from that of other organs, may play a role for this peculiar behavior, we investigated a series of 20 PCNSLs for the presence of lymphatic vessels by immunohistochemistry for Lyve-1, podoplanin, and Prox-1 expression. All PCNSLs lacked lymphatic vessels and, in this regard, were similar to 20 glioblastoma multiforme samples. In contrast to these tumors, all of which were located in the deep brain parenchyma, dural and meningeal DLBCL harbored lymphatic vessels that expressed Lyve-1 (3/8 tumors), podoplanin (5/8 tumors), and Prox-1 (5/8 tumors) in areas where the tumors had invaded the fibrous tissue of the dura. These data indicate that local topographical characteristics of the specific lymphatic drainage system may contribute to confinement of the tumor cells in PCNSL and malignant gliomas. © 2016 American Association of Neuropathologists, Inc. All rights reserved.

  7. Effects of pressure-controlled and volume-controlled ventilation on respiratory mechanics and systemic stress response during prone position.

    Science.gov (United States)

    Sen, Oznur; Bakan, Mefkur; Umutoglu, Tarik; Aydın, Nurdan; Toptas, Mehmet; Akkoc, Ibrahim

    2016-01-01

    Prone position during general anesthesia for special surgical operations may be related with increased airway pressure, decreased pulmonary and thoracic compliance that may be explained by restriction of chest expansion and compression of abdomen. The optimum ventilation mode for anesthetized patients on prone position was not described and studies comparing volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) during prone position are limited. We hypothesized that PCV instead of VCV during prone position could achieve lower airway pressures and reduce the systemic stress response. In this study, we aimed to compare the effects of PCV and VCV modes during prone position on respiratory mechanics, oxygenation, and hemodynamics, as well as blood cortisol and insulin levels, which has not been investigated before. Fifty-four ASA I-II patients, 18-70 years of age, who underwent percutaneous nephrolithotomy on prone position, were randomly selected to receive either the PCV (Group PC, n = 27) or VCV (Group VC, n = 27) under general anesthesia with sevoflurane and fentanyl. Blood sampling was made for baseline arterial blood gases (ABG), cortisol, insulin, and glucose levels. After anesthesia induction and endotracheal intubation, patients in Group PC were given pressure support to form 8 mL/kg tidal volume and patients in Group VC was maintained at 8 mL/kg tidal volume calculated using predicted body weight. All patients were maintained with 5 cmH2O PEEP. Respiratory parameters were recorded during supine and prone position. Assessment of ABG and sampling for cortisol, insulin and glucose levels were repeated during surgery and 60 min after extubation. P-peak and P-plateau levels during supine and prone positions were significantly higher and P-mean and compliance levels during prone position were significantly lower in Group VC when compared with Group PC. Postoperative PaO2 level was significantly higher in Group PC compared with Group

  8. New regulatory requirements of HVAC ventilation systems in nuclear installations Spanish; Nuevos requisitos reguladores de los sistemas de ventilacion HVAC en instalaciones nucleares espanolas

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, J. J.

    2011-07-01

    Ventilation systems serve a number of functions vital to the safe operation of nuclear facilities: the renewal of air, cooling components, prevent the release of contaminated air into the environment under both normal operating and accident, or ensure habitability of the control rooms in all situations.

  9. The Maintenance of Heating, Ventilating and Air-Conditioning Systems and Indoor Air Quality in Schools: A Guide for School Facility Managers. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    To help maintain good indoor air quality (IAQ) in schools, guidance for the development and implementation of an effective program for maintenance and operation of heating, ventilating, and air-conditioning (HVAC) systems are discussed. Frequently, a building's occupants will complain about IAQ when the temperature or humidity are at uncomfortable…

  10. Demand controlled ventilation in a bathroom

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Topp, Claus

    2008-01-01

    consumption during periods where the demand for ventilation is low and poor indoor climate during periods where the demand for ventilation is high. Controlling the ventilation rate by demand can improve the energy performance of the ventilation system and the indoor climate. This paper compares the indoor...... climate and energy consumption of a Constant Air Volume (CAV) system and a Demand Controlled Ventilation (DCV) system for two different bathroom designs. The air change rate of the CAV system corresponded to 0.5h-1. The ventilation rate of the DCV system was controlled by occupancy and by the relative....... The indoor climate and the energy consumption were estimated based on a simplified calculation of the variation of the water content within the bathroom during a day. The results showed that the DCV system controlled by occupancy and relative humidity had an improved energy performance and an improved indoor...

  11. The renin-angiotensin-aldosterone system in cerebral small vessel disease

    NARCIS (Netherlands)

    Brenner, D.; Labreuche, J.; Pico, F.; Scheltens, P.; Poirier, O.; Cambien, F.; Amarenco, P.

    2008-01-01

    Introduction: Cerebral small vessel disease (SVD) appears on magnetic resonance imaging (MRI) as leukoaraiosis (LA), état criblé (EC), and multiple lacunar infarctions (MLI). Although the pathophysiology of SVD is poorly understood, there is evidence of a genetic contribution. We sought to analyze

  12. Analysis of The Propulsion System Towards The Speed Reduction of Vessels Type PC-43

    Directory of Open Access Journals (Sweden)

    Arica Dwi Susanto

    2017-05-01

    Full Text Available (PC-43 is an Indonesian navy vessel type limited patrol craft made in Indonesian. The vessel was designed using a steel material with a maximum speed of 27 knots and using engine power by 3 x 1800 HP, T = 1.40 at the empty draft and T = 1.70 at full draft. The speed is decreased in the current conditions by 22 knots at 1.50 meters draft within 1 year after its launching. This fact is very interesting to be used as a paper project by analyzing the effect of changes in vessel’s draft to the resistance and analyze the current installed engine power, This paper carried two methods of calculation, namely: resistance and power calculation numerically along with resistance and power calculation using software maxsurf. The results from the manual calculations of power at T = 1.65 meters in 27 knots, the power needed is BHPscr = 4245.04 HP. From the data of power installed in the vessel, it was stated that the power is 3 x 1800 = 5400 HP, means a mathematical/theoretical speed of 27 knots can be achieved. Thus, the resistance and power is not one of the causes of speed reduction in Vessel Type PC- 43.

  13. Simulation test of aerosol generation from vessels in the pre-treatment system of fuel reprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Fujine, Sachio; Kitamura, Koichiro; Kihara, Takehiro [Japan Atomic Energy Research Institute (JAERI), Ibaraki-ken (Japan)

    1997-08-01

    Aerosol concentration and droplet size are measured in off-gas of vessel under various conditions by changing off-gas flow rate, stirring air flow rate, salts concentration and temperature of nitrate solution. Aerosols are also measured under evaporation and air-lift operation. 4 refs., 6 figs.

  14. Scaling Theory for Pulsed Jet Mixed Vessels, Sparging, and Cyclic Feed Transport Systems for Slurries

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, William L.; Rector, David R.; Rassat, Scot D.; Enderlin, Carl W.; Minette, Michael J.; Bamberger, Judith A.; Josephson, Gary B.; Wells, Beric E.; Berglin, Eric J.

    2013-09-27

    This document is a previously unpublished work based on a draft report prepared by Pacific Northwest National Laboratory (PNNL) for the Hanford Waste Treatment and Immobilization Plant (WTP) in 2012. Work on the report stopped when WTP’s approach to testing changed. PNNL is issuing a modified version of the document a year later to preserve and disseminate the valuable technical work that was completed. This document establishes technical bases for evaluating the mixing performance of Waste Treatment Plant (WTP) pretreatment process tanks based on data from less-than-full-scale testing, relative to specified mixing requirements. The technical bases include the fluid mechanics affecting mixing for specified vessel configurations, operating parameters, and simulant properties. They address scaling vessel physical performance, simulant physical performance, and “scaling down” the operating conditions at full scale to define test conditions at reduced scale and “scaling up” the test results at reduced scale to predict the performance at full scale. Essentially, this document addresses the following questions: • Why and how can the mixing behaviors in a smaller vessel represent those in a larger vessel? • What information is needed to address the first question? • How should the information be used to predict mixing performance in WTP? The design of Large Scale Integrated Testing (LSIT) is being addressed in other, complementary documents.

  15. 75 FR 63445 - Vessel Monitoring Systems; Approved Mobile Transmitting Units and Communications Service...

    Science.gov (United States)

    2010-10-15

    ... 750VMS with VTERM transceiver consists of an integrated dual model GPS/GSM/GPRS/Iridium Satellite... when the vessel goes to sea. The Faria WatchDog 750VMS has omni-directional Iridium, GPS, and GSM/GPRS antennas, providing operation from 5 degrees above or below the horizon anywhere on Earth. The GSM/GPRS...

  16. Performance of personalized ventilation in a room with an underfloor air distribution system: transport of contaminants between occupants

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2003-01-01

    Studies have documented that personalized ventilation, which provides clean air at each office workplace, is able to improve substantially the quality of air inhaled by occupants. However, the interaction between the airflow generated by personalized ventilation and the airflow pattern outside th...

  17. Boundary conditions for the use of personal ventilation over mixing ventilation in open plan offices

    DEFF Research Database (Denmark)

    Petersen, Steffen; Hviid, Christian Anker

    2013-01-01

    This paper investigates the boundary conditions for choosing a combined Personal Ventilation (PV) and Mixing Ventilation (MV) over conventional mixing ventilation in an office with multiple workers. A simplified procedure for annual performance assessment of PV/MV systems in terms of air quality,...

  18. 46 CFR 194.15-5 - Ventilation.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Ventilation. 194.15-5 Section 194.15-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194...

  19. Comparison of MLP neural network and neuro-fuzzy system in transcranial Doppler signals recorded from the cerebral vessels.

    Science.gov (United States)

    Hardalaç, Firat

    2008-04-01

    Transcranial Doppler signals recorded from cerebral vessels of 110 patients were transferred to a personal computer by using a 16 bit sound card. Spectral analyses of Transcranial Doppler signals were performed for determining the Multi Layer Perceptron (MLP) neural network and neuro Ankara-fuzzy system inputs. In order to do a good interpretation and rapid diagnosis, FFT parameters of Transcranial Doppler signals classified using MLP neural network and neuro-fuzzy system. Our findings demonstrated that 92% correct classification rate was obtained from MLP neural network, and 86% correct classification rate was obtained from neuro-fuzzy system.

  20. Contaminant Distribution Around Persons in Rooms Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter V.

    An optimal design of the ventilation system needs a proper prediction of the velocity, temperature and contaminant distribution in the room. Traditionally this is done either by the use of simplified models or by a somewhat more comprehensive CFD-simulation. Common to both methods is usually the ...... the lack of consideration for the persons present in the room. This paper deals with some of the effects of persons present in a displacement ventilated room, especially the effect on the contaminant distribution....

  1. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  2. 2011 Passenger Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  3. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  4. 2013 Passenger Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  5. 2013 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  6. 2013 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  7. 2011 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  8. 2011 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  9. 2013 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  10. Application of acoustic agglomeration to enhance air filtration efficiency in air-conditioning and mechanical ventilation (ACMV) systems

    Science.gov (United States)

    Xiong, Jin Wen; Wan, Man Pun

    2017-01-01

    The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV) systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency. PMID:28594862

  11. Application of acoustic agglomeration to enhance air filtration efficiency in air-conditioning and mechanical ventilation (ACMV systems.

    Directory of Open Access Journals (Sweden)

    Bing Feng Ng

    Full Text Available The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency.

  12. Application of acoustic agglomeration to enhance air filtration efficiency in air-conditioning and mechanical ventilation (ACMV) systems.

    Science.gov (United States)

    Ng, Bing Feng; Xiong, Jin Wen; Wan, Man Pun

    2017-01-01

    The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV) systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency.

  13. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    -cooling period and night cooling potential. The investment cost of this ventilation system is about 5-10% lower than the conventional ones, because the acoustic ceiling could be directly applied as air diffuser and the use of plenum to distribute air reduces the cost of ductwork. There is a growing interest...... and manufacturers and the users of diffuse ceiling technology. The design guide introduces the principle and key characteristics of room air distribution with diffuse ceiling ventilation. It provides an overview of potential benefit and limitations of this technology. The benefits include high thermal comfort, high...... cooling capacity, energy saving, low investment cost and low noise level; while the limitations include condensation risk and the limit on the room geometry. Furthermore, the crucial design parameters are summarized and their effects on the system performance are discussed. In addition to the stand...

  14. Reliability-based dynamic positioning of floating vessels with riser and mooring system

    DEFF Research Database (Denmark)

    Fang, Shaoji; Leira, Bernt J.; Blanke, Mogens

    2011-01-01

    To maintain safety of a floating vessel with associated slender components such as risers and mooring line, the vessel is normally kept within a limited region. To specify a safe position in that region, this paper suggests a new position chasing algorithm with the consideration of both riser...... angles and mooring line tensions. The riser angles were considered in an object function in [1] and the mooring line tension was considered in an object function in [2]. The contribution of this paper is to combine riser angle and mooring line tension together in one unified object function....... A combination of scaled riser angles and structural reliability index is utilized to evaluate the “reserve capacity” relative to failure events. With this object function, the riser angles and mooring line tension are considered in a unified formulation, with higher weight added to the riser angles due...

  15. Microwave release ofpectin from orange peel albedo using a closed vessel reactor system

    Science.gov (United States)

    Pectin was extracted from blood Moro orange in a closed vessel reactor heated with microwave irradiation. Time of heating was either 2 minutes at 110 °C or 210 minutes at 75 °C in pH range of 1.7 to 2.8. The run at 75 °C and a pH 1.7 with resistive heating was performed to simulate industrial proces...

  16. Elastomeric free-form blood vessels for interconnecting organs on chip systems.

    Science.gov (United States)

    Zhang, Weijia; Zhang, Yu Shrike; Bakht, Syeda Mahwish; Aleman, Julio; Shin, Su Ryon; Yue, Kan; Sica, Marco; Ribas, João; Duchamp, Margaux; Ju, Jie; Sadeghian, Ramin Banan; Kim, Duckjin; Dokmeci, Mehmet Remzi; Atala, Anthony; Khademhosseini, Ali

    2016-04-26

    Conventional blood vessel-on-a-chip models are typically based on microchannel-like structures enclosed within bulk elastomers such as polydimethylsiloxane (PDMS). However, these bulk vascular models largely function as individual platforms and exhibit limited flexibility particularly when used in conjunction with other organ modules. Oftentimes, lengthy connectors and/or tubes are still needed to interface multiple chips, resulting in a large waste volume counterintuitive to the miniaturized nature of organs-on-chips. In this work, we report the development of a novel form of a vascular module based on PDMS hollow tubes, which closely emulates the morphology and properties of human blood vessels to integrate multiple organs-on-chips. Specifically, we present two templating strategies to fabricate hollow PDMS tubes with adjustable diameters and wall thicknesses, where metal rods or airflow were employed as the inner templates, while plastic tubes were used as the outer template. The PDMS tubes could then be functionalized by human umbilical vein endothelial cells (HUVECs) in their interior surfaces to further construct elastomeric biomimetic blood vessels. The endothelium developed biofunctionality as demonstrated by the expression of an endothelial biomarker (CD31) as well as dose-dependent responses in the secretion of von Willebrand factor and nitric oxide upon treatment with pharmaceutical compounds. We believe that with their clear advantages including high optical transparency, gas permeability, and tunable elasticity matching those of native blood vessels, these free-form PDMS vascular modules can supplement bulk vascular organoids and likely replace inert plastic tubes in integrating multiple organoids into a single microfluidic circuitry.

  17. Elastomeric Free-Form Blood Vessels for Interconnecting Organs on Chip Systems

    Science.gov (United States)

    Zhang, Weijia; Zhang, Yu Shrike; Bakht, Syeda Mahwish; Aleman, Julio; Shin, Su-Ryon; Yue, Kan; Sica, Marco; Ribas, João; Duchamp, Margaux; Ju, Jie; Sadeghian, Ramin Banan; Kim, Duckjin; Dokmeci, Mehmet Remzi; Atala, Anthony; Khademhosseini, Ali

    2016-01-01

    Conventional blood vessel-on-a-chip models are typically based on microchannel-like structures enclosed within bulk elastomers such as polydimethylsiloxane (PDMS). However, these bulk vascular models largely function as individual platforms and exhibit limited flexibility particularly when used in conjunction with other organ modules. Oftentimes lengthy connectors and/or tubes are still needed to interface multiple chips, resulting in a large waste volume counterintuitive to the miniaturized nature of the organs-on-chips. In this work, we report the development of a novel form of vascular module based on PDMS hollow tubes, which closely emulates the morphology and properties of the human blood vessels to integrate multiple organ-on-chips. Specifically, we present two templating strategies to fabricate hollow PDMS tubes with adjustable diameters and wall thicknesses, where metal rods or airflow were employed as the inner templates, while plastic tubes were used as the outer template. The PDMS tubes could then be functionalized by human umbilical vein endothelial cells (HUVECs) in their interior surfaces to further construct the elastomeric biomimetic blood vessels. The endothelium developed biofunctionality as demonstrated by the expression of endothelial biomarker CD31 as well as dose-dependent responses in the secretion of von Willebrand factor and nitric oxide upon treatment with pharmaceutical compounds. We believe that, with their clear advantages including high optical transparency, gas permeability, and tunable elasticity matching those of native blood vessels, these free-form PDMS vascular modules can supplement the bulk vascular organoids and likely replace the inert plastic tubes in integrating multiple organoids into a single microfluidic circuitry. PMID:26999423

  18. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    by the research vessels RV Gaveshani and ORV Sagar Kanya are reported. The work carried out by the three charted ships is also recorded. A short note on cruise plans for the study of ferromanganese nodules is added...

  19. Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

    Science.gov (United States)

    Möritz, M; Peters, H; Nipko, B; Rüden, H

    2001-07-01

    The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 degrees C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70% and molds by > 80%). However, during long periods of high relative humidity (> 80% R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occurred. These microorganisms were mainly smaller than 1.1 microns therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80% R. H. (mean of 3 days), e.g. by using preheaters in front of air filters in HVAC-systems.

  20. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings – Guideline of the German Society for Hospital Hygiene (DGKH

    Directory of Open Access Journals (Sweden)

    Külpmann, Rüdiger

    2016-02-01

    Full Text Available Since the publication of the first “Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems in hospitals” ( in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section “Ventilation and air conditioning technology” attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  1. Applications of computational fluid dynamics (CFD) in the modelling and design of ventilation systems in the agricultural industry: a review.

    Science.gov (United States)

    Norton, Tomás; Sun, Da-Wen; Grant, Jim; Fallon, Richard; Dodd, Vincent

    2007-09-01

    The application of computational fluid dynamics (CFD) in the agricultural industry is becoming ever more important. Over the years, the versatility, accuracy and user-friendliness offered by CFD has led to its increased take-up by the agricultural engineering community. Now CFD is regularly employed to solve environmental problems of greenhouses and animal production facilities. However, due to a combination of increased computer efficacy and advanced numerical techniques, the realism of these simulations has only been enhanced in recent years. This study provides a state-of-the-art review of CFD, its current applications in the design of ventilation systems for agricultural production systems, and the outstanding challenging issues that confront CFD modellers. The current status of greenhouse CFD modelling was found to be at a higher standard than that of animal housing, owing to the incorporation of user-defined routines that simulate crop biological responses as a function of local environmental conditions. Nevertheless, the most recent animal housing simulations have addressed this issue and in turn have become more physically realistic.

  2. Summary of human responses to ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli A.; Fisk, William J.

    2004-06-01

    The effects of ventilation on indoor air quality and health is a complex issue. It is known that ventilation is necessary to remove indoor generated pollutants from indoor air or dilute their concentration to acceptable levels. But, as the limit values of all pollutants are not known, the exact determination of required ventilation rates based on pollutant concentrations and associated risks is seldom possible. The selection of ventilation rates has to be based also on epidemiological research (e.g. Seppanen et al., 1999), laboratory and field experiments (e.g. CEN 1996, Wargocki et al., 2002a) and experience (e.g. ECA 2003). Ventilation may also have harmful effects on indoor air quality and climate if not properly designed, installed, maintained and operated as summarized by Seppdnen (2003). Ventilation may bring indoors harmful substances that deteriorate the indoor environment. Ventilation also affects air and moisture flow through the building envelope and may lead to moisture problems that deteriorate the structures of the building. Ventilation changes the pressure differences over the structures of building and may cause or prevent the infiltration of pollutants from structures or adjacent spaces. Ventilation is also in many cases used to control the thermal environment or humidity in buildings. Ventilation can be implemented with various methods which may also affect health (e.g. Seppdnen and Fisk, 2002, Wargocki et al., 2002a). In non residential buildings and hot climates, ventilation is often integrated with air-conditioning which makes the operation of ventilation system more complex. As ventilation is used for many purposes its health effects are also various and complex. This paper summarizes the current knowledge on positive and negative effects of ventilation on health and other human responses. The focus of the paper is on office-type working environment and residential buildings. In the industrial premises the problems of air quality are usually

  3. Variable mechanical ventilation

    Science.gov (United States)

    Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini Jr., Luiz Alberto; Friedman, Gilberto

    2017-01-01

    Objective To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Methods Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE®, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". Results A total of 36 studies were selected. Of these, 24 were original studies, including 21 experimental studies and three clinical studies. Conclusion Several experimental studies reported the beneficial effects of distinct variable ventilation strategies on lung function using different models of lung injury and healthy lungs. Variable ventilation seems to be a viable strategy for improving gas exchange and respiratory mechanics and preventing lung injury associated with mechanical ventilation. However, further clinical studies are necessary to assess the potential of variable ventilation strategies for the clinical improvement of patients undergoing mechanical ventilation. PMID:28444076

  4. Variable mechanical ventilation.

    Science.gov (United States)

    Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini, Luiz Alberto; Friedman, Gilberto

    2017-01-01

    To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE®, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". A total of 36 studies were selected. Of these, 24 were original studies, including 21 experimental studies and three clinical studies. Several experimental studies reported the beneficial effects of distinct variable ventilation strategies on lung function using different models of lung injury and healthy lungs. Variable ventilation seems to be a viable strategy for improving gas exchange and respiratory mechanics and preventing lung injury associated with mechanical ventilation. However, further clinical studies are necessary to assess the potential of variable ventilation strategies for the clinical improvement of patients undergoing mechanical ventilation.

  5. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  6. Variable mechanical ventilation

    OpenAIRE

    Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini Jr.,Luiz Alberto; Friedman, Gilberto

    2017-01-01

    Objective To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Methods Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE?, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". Results A total of 36 studies were selected. ...

  7. Displacement Ventilation in a Room with Low-Level Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    Ventilation systems with vertical displacement flow have been used in industrial areas with high thermal loads for many years. Quite resently the vertical displacement flow systems have grown popular as comfort ventilation in rooms with thermal loads e.g. offices.......Ventilation systems with vertical displacement flow have been used in industrial areas with high thermal loads for many years. Quite resently the vertical displacement flow systems have grown popular as comfort ventilation in rooms with thermal loads e.g. offices....

  8. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  9. Effects of pressure-controlled and volume-controlled ventilation on respiratory mechanics and systemic stress response during laparoscopic cholecystectomy.

    Science.gov (United States)

    Sen, Oznur; Umutoglu, Tarik; Aydın, Nurdan; Toptas, Mehmet; Tutuncu, Ayse Cigdem; Bakan, Mefkur

    2016-01-01

    Pressure-controlled ventilation (PCV) is less frequently employed in general anesthesia. With its high and decelerating inspiratory flow, PCV has faster tidal volume delivery and different gas distribution. The same tidal volume setting, delivered by PCV versus volume-controlled ventilation (VCV), will result in a lower peak airway pressure and reduced risk of barotrauma. We hypothesized that PCV instead of VCV during laparoscopic surgery could achieve lower airway pressures and reduce the systemic stress response. Forty ASA I-II patients were randomly selected to receive either the PCV (Group PC, n = 20) or VCV (Group VC, n = 20) during laparoscopic cholecystectomy. Blood sampling was made for baseline arterial blood gases (ABG), cortisol, insulin, and glucose levels. General anesthesia with sevoflurane and fentanyl was employed to all patients. After anesthesia induction and endotracheal intubation, patients in Group PC were given pressure support to form 8 mL/kg tidal volume and patients in Group VC was maintained at 8 mL/kg tidal volume calculated using predicted body weight. All patients were maintained with 5 cmH2O positive-end expiratory pressure (PEEP). Respiratory parameters were recorded before and 30 min after pneumoperitonium. Assessment of ABG and sampling for cortisol, insulin and glucose levels were repeated 30 min after pneumoperitonium and 60 min after extubation. The P-peak levels observed before (18.9 ± 3.8 versus 15 ± 2.2 cmH2O) and during (23.3 ± 3.8 versus 20.1 ± 2.9 cmH2O) pneumoperitoneum in Group VC were significantly higher. Postoperative partial arterial oxygen pressure (PaO2) values are higher (98 ± 12 versus 86 ± 11 mmHg) in Group PC. Arterial carbon dioxide pressure (PaCO2) values (41.8 ± 5.4 versus 36.7 ± 3.5 mmHg) during pneumoperitonium and post-operative mean cortisol and insulin levels were higher in Group VC. When compared to VCV mode, PCV mode may improve compliance during pneumoperitoneum

  10. Thermal comfort of seated occupants in rooms with personalized ventilation combined with mixing or displacement ventilation

    DEFF Research Database (Denmark)

    Forejt, L.; Melikov, Arsen Krikor; Cermak, Radim

    2004-01-01

    The performance of two personalized ventilation systems combined with mixing or displacement ventilation was studied under different conditions in regard to thermal comfort of seated occupants. The cooling performance of personalized ventilation was found to be independent of room air distribution....... Differences between the personalized air terminal devices were identified in terms of the cooling distribution over the manikin¿s body. The personalized ventilation supplying air from the front towards the face provided a more uniform cooling of the body than the personalized ventilation supplying air from...

  11. Moving horizon control and estimation of livestock ventilation systems and indoor climate

    DEFF Research Database (Denmark)

    Wu, Zhuang; Stoustrup, Jakob; Jørgensen, John Bagterp

    2008-01-01

    In this paper, a new control strategy involves exploiting actuator redundancy in a multivariable system is developed for rejecting the covariance of the fast frequency disturbances and pursuing optimum energy solution. This strategy enhances the resilience of the control system to disturbances be...

  12. Numerical simulation of a cabin ventilation subsystem in a space station oriented real-time system

    Directory of Open Access Journals (Sweden)

    Zezheng QIU

    2017-12-01

    Full Text Available An environment control and life support system (ECLSS is an important system in a space station. The ECLSS is a typical complex system, and the real-time simulation technology can help to accelerate its research process by using distributed hardware in a loop simulation system. An implicit fixed time step numerical integration method is recommended for a real-time simulation system with time-varying parameters. However, its computational efficiency is too low to satisfy the real-time data interaction, especially for the complex ECLSS system running on a PC cluster. The instability problem of an explicit method strongly limits its application in the ECLSS real-time simulation although it has a high computational efficiency. This paper proposes an improved numerical simulation method to overcome the instability problem based on the explicit Euler method. A temperature and humidity control subsystem (THCS is firstly established, and its numerical stability is analyzed by using the eigenvalue estimation theory. Furthermore, an adaptive operator is proposed to avoid the potential instability problem. The stability and accuracy of the proposed method are investigated carefully. Simulation results show that this proposed method can provide a good way for some complex time-variant systems to run their real-time simulation on a PC cluster. Keywords: Numerical integration method, Real-time simulation, Stability, THCS, Time-variant system

  13. Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.

    Science.gov (United States)

    Agodi, A; Auxilia, F; Barchitta, M; Cristina, M L; D'Alessandro, D; Mura, I; Nobile, M; Pasquarella, C

    2015-07-01

    Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. To evaluate airborne microbial contamination in OTs during hip and knee replacement surgery, and compare the findings with values recommended for joint replacement surgery. Air samplings were performed in 28 OTs supplied with unidirectional, turbulent and mixed airflow ventilation. Samples were collected using passive sampling to determine the index of microbial air contamination (IMA). Active sampling was also performed in some of the OTs. The average number of people in the OT and the number of door openings during the sampling period were recorded. In total, 1228 elective prosthesis procedures (60.1% hip and 39.9% knee) were included in this study. Of passive samplings performed during surgical activity in unidirectional airflow ventilation OTs (U-OTs) and mixed airflow OTs (M-OTs), 58.9% and 87.6% had IMA values >2, respectively. Of samplings performed during surgical activity in turbulent airflow OTs (T-OTs) and in turbulent airflow OTs with the surgical team wearing Steri-Shield Turbo Helmets (TH-OTs), 8.6% and 60% had IMA values ≤ 2, respectively. Positive correlation was found between IMA values and the number of people in the OT and the number of door openings (P systems always provide acceptable airborne bacterial counts. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Decreased respiratory system compliance on the sixth day of mechanical ventilation is a predictor of death in patients with established acute lung injury

    Directory of Open Access Journals (Sweden)

    Matthay Michael A

    2011-04-01

    Full Text Available Abstract Background Multiple studies have identified single variables or composite scores that help risk stratify patients at the time of acute lung injury (ALI diagnosis. However, few studies have addressed the important question of how changes in pulmonary physiologic variables might predict mortality in patients during the subacute or chronic phases of ALI. We studied pulmonary physiologic variables, including respiratory system compliance, P/F ratio and oxygenation index, in a cohort of patients with ALI who survived more than 6 days of mechanical ventilation to see if changes in these variables were predictive of death and whether they are informative about the pathophysiology of subacute ALI. Methods Ninety-three patients with ALI who were mechanically ventilated for more than 6 days were enrolled in this prospective cohort study. Patients were enrolled at two medical centers in the US, a county hospital and a large academic center. Bivariate analyses were used to identify pulmonary physiologic predictors of death during the first 6 days of mechanical ventilation. Predictors on day 1, day 6 and the changes between day 1 and day 6 were compared in a multivariate logistic regression model. Results The overall mortality was 35%. In multivariate analysis, the PaO2/FiO2 (OR 2.09, p th day of acute lung injury. In addition, a decrease in respiratory system compliance between days 1 and days 6 (OR 2.14, p Conclusions A low respiratory system compliance on day 6 or a decrease in the respiratory system compliance between the 1st and 6th day of mechanical ventilation were associated with increased mortality in multivariate analysis of this cohort of patients with ALI. We suggest that decreased respiratory system compliance may identify a subset of patients who have persistent pulmonary edema, atelectasis or the fibroproliferative sequelae of ALI and thus are less likely to survive their hospitalization.

  15. Study of Air Pollution Due to Plasma Cutting Process and Designing Local Ventilation System with Collector in Central Workshop of Mobarakeh Steel Company

    Directory of Open Access Journals (Sweden)

    Farideh Atabi

    2014-06-01

    Full Text Available Background & Objectives : Cutting leads to production of different hazardous agents such as fumes, particles, gases and vapors. In various studies, the effects of fumes, gases, and vapors on workers and environment have been proved. Meanwhile, cutting alloying plates with plasma cutting machine due to containing various alloy materials produces a lot of air pollution. Therefore, using the ventilation system to remove the mentioned pollution has always been noteworthy. Method: This study was performed on plasma cutting machine at Mobarakeh Steel Company. At first, according to ASTM the elements from alloy plates with optical emission spectrometry crm-35000-quantometery were detected, the air pollution from cutting the mentioned plates was sampled and measured using NIOSH 7300 method and according to the ACGIH:VS-72-20, VS-70-12, VS-70-11 VS-916 push-pull ventilation with bag filter collector was designed. Results: Results of sampling from pollution of cutting the alloy material, concentration of iron, lead and cadmium fumes were more than the standard limits. After calculation for push system, air flow volume of 195.163 cfm, outgoing air velocity of 5937.4 fpm and for pull system air flow volume of 12498 cfm, minimum duct velocity of 3000 fpm and velocity pressure of duct of 0.717 inwg, for fan, total pressure of 6.301 inwg, static pressure of 0.587 inwg and power of 20.65 Bhp and for collector with pulse jet cleaning system air to cloth ratio of 7 and dimensions of 6.88ft × 6.56ft × 9.84ft were obtained. Conclusion: The result of study indicated that push pull ventilation compared to other ventilation system s for plasma cutting has more efficiency and makes suitable control for pollution.

  16. Fan System Optimization Improves Ventilation and Saves Energy at a Computer Chip Manufacturer

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-01-01

    This case study describes an optimization project implemented on a fan system at Ash Grove Cement Company, which led to annual energy and maintenance savings of $16,000 and 175,000 kilowatt-hours (kWh).

  17. TECHNICAL BASIS DOCUMENT FOR VENTILATION SYSTEM FILTRATION FAILURE LEADING TO AN UNFILTERED RELEASE

    Energy Technology Data Exchange (ETDEWEB)

    KOZLOWSKI, S.D.

    2005-01-06

    This document analyzed three scenarios involving failures of HEPA filtration systems leading to releases from liquid waste tanks. The scenarios are failure due to high temperature (fire), overpressure (filter blowout), and unfiltered release due to filter failure, improper installation. etc.

  18. Experimental study of hybrid interface cooling system using air ventilation and nanofluid

    Science.gov (United States)

    Rani, M. F. H.; Razlan, Z. M.; Bakar, S. A.; Desa, H.; Wan, W. K.; Ibrahim, I.; Kamarrudin, N. S.; Bin-Abdun, Nazih A.

    2017-09-01

    The hybrid interface cooling system needs to be established to chill the battery compartment of electric car and maintained its ambient temperature inside the compartment between 25°C to 35°C. The air cooling experiment has been conducted to verify the cooling capacity, compressor displacement volume, dehumidifying value and mass flow rate of refrigerant (R-410A). At the same time, liquid cooling system is analysed theoretically by comparing the performance of two types of nanofluid, i.e., CuO + Water and Al2O3 + Water, based on the heat load generated inside the compartment. In order for the result obtained to be valid and reliable, several assumptions are considered during the experimental and theoretical analysis. Results show that the efficiency of the hybrid interface cooling system is improved as compared to the individual cooling system.

  19. Dynamic oxygen transfer measurements under operating conditions as a basis for the optimization of ventilation systems; Dynamische Sauerstoffeintragsmessungen unter Betriebsbedingungen als Grundlage zur Optimierung von Belueftungssystemen

    Energy Technology Data Exchange (ETDEWEB)

    Libra, J.A.; Biskup, M.; Wiesmann, U. [Technische Univ. Berlin (Germany). Inst. fuer Verfahrenstechnik; Sahlmann, C.; Gnirss, R. [Berliner Wasserbetriebe, Berlin (Germany)

    1999-07-01

    The largest single energy consumer at sewage treatment plants is the ventilation system of activated sludge tanks. This is why controlling and optimizing ventilation systems is the most appropriate approach to the cutting down of energy costs. The present paper reports on measurements of dynamic oxygen transfer by means of the off-gas method under operating conditions at the Berlin-Ruhleben sewage treatment plant. (orig.) [German] Der groesste Einzelenergieverbraucher auf Klaerwerken ist das Belueftungssystem von Belebungsbecken. Deshalb ist die Kontrolle und Optimierung der Belueftungssysteme der geeignete Weg zur Verringerung der Energiekosten. In diesem Beitrag wird ueber Messungen des dynamischen Sauerstoffeintrags mit der Abluft-Methode unter Betriebsbedingungen im Klaerwerk Berlin-Ruhleben berichtet. (orig.)

  20. Meta-Analysis of Data from the Submarine Ventilation Doctrine Test Program

    National Research Council Canada - National Science Library

    Hoover, J

    1998-01-01

    .... The Submarine Ventilation Doctrine Test Program was developed to address submarine-specific issues regarding the use of ventilation systems to control smoke and heat movement, maintain habitability...

  1. Randomized crossover trial of a pressure sensing visual feedback system to improve mask fitting in noninvasive ventilation.

    Science.gov (United States)

    Brill, Anne-Kathrin; Moghal, Mohammad; Morrell, Mary J; Simonds, Anita K

    2017-10-01

    A good mask fit, avoiding air leaks and pressure effects on the skin are key elements for a successful noninvasive ventilation (NIV). However, delivering practical training for NIV is challenging, and it takes time to build experience and competency. This study investigated whether a pressure sensing system with real-time visual feedback improved mask fitting. During an NIV training session, 30 healthcare professionals (14 trained in mask fitting and 16 untrained) performed two mask fittings on the same healthy volunteer in a randomized order: one using standard mask-fitting procedures and one with additional visual feedback on mask pressure on the nasal bridge. Participants were required to achieve a mask fit with low mask pressure and minimal air leak (bridge, perceived comfort of mask fit and staff- confidence were measured. Compared with standard mask fitting, a lower pressure was exerted on the nasal bridge using the feedback system (71.1 ± 17.6 mm Hg vs 63.2 ± 14.6 mm Hg, P bridge (74.5 ± 21.2 mm Hg vs 66.1 ± 17.4 mm Hg, P = 0.023 and 67 ± 12.1 mm Hg vs 60 ± 10.6 mm Hg, P = 0.002, respectively) using the feedback system and self-rated confidence increased in the untrained group. Real-time visual feedback using pressure sensing technology supported healthcare professionals during mask-fitting training, resulted in a lower pressure on the skin and better mask fit for the volunteer, with increased staff confidence. © 2017 Asian Pacific Society of Respirology.

  2. Wings as impellers: honey bees co-opt flight system to induce nest ventilation and disperse pheromones.

    Science.gov (United States)

    Peters, Jacob M; Gravish, Nick; Combes, Stacey A

    2017-06-15

    Honey bees (Apis mellifera) are remarkable fliers that regularly carry heavy loads of nectar and pollen, supported by a flight system - the wings, thorax and flight muscles - that one might assume is optimized for aerial locomotion. However, honey bees also use this system to perform other crucial tasks that are unrelated to flight. When ventilating the nest, bees grip the surface of the comb or nest entrance and fan their wings to drive airflow through the nest, and a similar wing-fanning behavior is used to disperse volatile pheromones from the Nasonov gland. In order to understand how the physical demands of these impeller-like behaviors differ from those of flight, we quantified the flapping kinematics and compared the frequency, amplitude and stroke plane angle during these non-flight behaviors with values reported for hovering honey bees. We also used a particle-based flow visualization technique to determine the direction and speed of airflow generated by a bee performing Nasonov scenting behavior. We found that ventilatory fanning behavior is kinematically distinct from both flight and scenting behavior. Both impeller-like behaviors drive flow parallel to the surface to which the bees are clinging, at typical speeds of just under 1 m s-1 We observed that the wings of fanning and scenting bees frequently contact the ground during the ventral stroke reversal, which may lead to wing wear. Finally, we observed that bees performing Nasonov scenting behavior sometimes display 'clap-and-fling' motions, in which the wings contact each other during the dorsal stroke reversal and fling apart at the start of the downstroke. We conclude that the wings and flight motor of honey bees comprise a multifunctional system, which may be subject to competing selective pressures because of its frequent use as both a propeller and an impeller. © 2017. Published by The Company of Biologists Ltd.

  3. Angiotensin II type 1 and 2 receptors and lymphatic vessels modulate lung remodeling and fibrosis in systemic sclerosis and idiopathic pulmonary fibrosis.

    Science.gov (United States)

    Parra, Edwin Roger; Ruppert, Aline Domingos Pinto; Capelozzi, Vera Luiza

    2014-01-01

    To validate the importance of the angiotensin II receptor isotypes and the lymphatic vessels in systemic sclerosis and idiopathic pulmonary fibrosis. We examined angiotensin II type 1 and 2 receptors and lymphatic vessels in the pulmonary tissues obtained from open lung biopsies of 30 patients with systemic sclerosis and 28 patients with idiopathic pulmonary fibrosis. Their histologic patterns included cellular and fibrotic non-specific interstitial pneumonia for systemic sclerosis and usual interstitial pneumonia for idiopathic pulmonary fibrosis. We used immunohistochemistry and histomorphometry to evaluate the number of cells in the alveolar septae and the vessels stained by these markers. Survival curves were also used. We found a significantly increased percentage of septal and vessel cells immunostained for the angiotensin type 1 and 2 receptors in the systemic sclerosis and idiopathic pulmonary fibrosis patients compared with the controls. A similar percentage of angiotensin 2 receptor positive vessel cells was observed in fibrotic non-specific interstitial pneumonia and usual interstitial pneumonia. A significantly increased percentage of lymphatic vessels was present in the usual interstitial pneumonia group compared with the non-specific interstitial pneumonia and control groups. A Cox regression analysis showed a high risk of death for the patients with usual interstitial pneumonia and a high percentage of vessel cells immunostained for the angiotensin 2 receptor in the lymphatic vessels. We concluded that angiotensin II receptor expression in the lung parenchyma can potentially control organ remodeling and fibrosis, which suggests that strategies aimed at preventing high angiotensin 2 receptor expression may be used as potential therapeutic target in patients with pulmonary systemic sclerosis and idiopathic pulmonary fibrosis.

  4. Wii, Kinect, and Move. Heart Rate, Oxygen Consumption, Energy Expenditure, and Ventilation due to Different Physically Active Video Game Systems in College Students

    OpenAIRE

    SCHEER, KRISTA S.; SIEBRANT, SARAH M.; Brown, Gregory A.; Brandon S. Shaw; Shaw, Ina

    2014-01-01

    Nintendo Wii, Sony Playstation Move, and Microsoft XBOX Kinect are home video gaming systems that involve player movement to control on-screen game play. Numerous investigations have demonstrated that playing Wii is moderate physical activity at best, but Move and Kinect have not been as thoroughly investigated. The purpose of this study was to compare heart rate, oxygen consumption, and ventilation while playing the games Wii Boxing, Kinect Boxing, and Move Gladiatorial Combat. Heart rate, o...

  5. Use of solar electricity in near-production vehicles. [Solar-assisted air conditioning and electrical system; also ventilation of parked car

    Energy Technology Data Exchange (ETDEWEB)

    Grundmann, E.; Koenig, A. (Volkswagen AG, Research-New Technologies/ Energy Systems (DE))

    1992-01-01

    In a research project, support by the EEC, possible applications of PV power in near production passenger cars were examined. Solar ventilation of parked cars lowers the heat build up in the sun by more than 50%. Solar assisted a.c. systems can be designed for lower power input at improved performance. Supplying the electrical power for the vehicle consumers from a solar panel instead of the vehicles alternator lead to fuel economy improvements of 3 to 9%. (author).

  6. System Design for Demand Controlled Ventilation in Multi-Family Dwellings

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer

    2011-01-01

    exchanger should not exceed 3400 DKK per dwelling in regions with weather conditions similar to the Danish climate. A design expected to fulfil this requirement was investigated in detail with regard to its electricity consumption by evaluation of different control strategies. Systems with variable airflows...... are typically controlled by maintaining the static pressure at a fixed level at a selected point in the main duct. However, sustaining the static pressure at a fixed level at part load leads to throttling of all control components and thereby unnecessary energy consumption. Resetting the static pressure at part...... load reduces throttling and energy can be saved. A static pressure reset strategy was applied to a dwelling-specific DCV system where the airflow varied between three fixed rates. The system performance was evaluated for two diffusers. The annual electricity consumption was reduced by 20% to 30% when...

  7. Middle ear ventilation status postoperatively after translabyrinthine resection of vestibular schwannoma with mastoid obliteration and Eustachian tube occlusion: is the Eustachian tube enough to ventilate the middle ear without the mastoid air cell system?

    Science.gov (United States)

    Belyea, James; Wickens, Brandon; Bance, Manohar

    2016-08-30

    Gas pressure balance is essential for maintaining normal middle ear function. The mucosal surfaces of the middle ear, the mastoid air cell system (MACS), and the Eustachian tube (ET) play a critical role in this process; however, the extent that each of these factors contributes to overall middle ear ventilation is unknown. The objective of this study was to determine if the ET alone can maintain normal middle ear pressure without the MACS. To do this, we reviewed subjects who had their MACS completely removed with translabyrinthine (TL) surgery for vestibular schwannoma. A retrospective chart review was done to collect pre and postoperative tympanometry data from patients who underwent resection of vestibular schwannoma. Data from the operative side was compared to the non-operative side at 2 years post-op. Twenty-four patients were included in this study. Of these, 63 % achieved a type A tympanogram at 2 years post-op in the TL resection group, implying an ability to maintain middle ear pressure in the absence of a mastoid cavity. Because some had negative pressures post TL resection, the average change in pre and postoperative pressure was -37.5 daPa for the operative side and 7.8 daPa for the non-operative side. This was significantly different. The difference for change in pre and postoperative pressure and compliance between operative and non-operative side might be expected from the ET plugging during TL resection. However, more interesting are those patients in whom the ET presumably reopens, and in these subjects, despite having no mastoid compartment at all, and the space obliterated with fat, they were still able to maintain normal ventilation of the middle ear space. Our findings imply that the ET alone is adequate to ventilate at least the reduced middle ear space following TL surgery in most subjects, and perhaps in 100 % if the ET hadn't been plugged during surgery. Hence, the mastoid air cell system, even when healthy, is not needed to maintain

  8. An Intelligent Energy Saving System for Controlling the Lighting and Ventilation of an Area

    OpenAIRE

    Kadiri Kamoru. O; Omotosho O. J

    2014-01-01

    Intelligent Energy Saving System is a control system used to control a particular environment in other to optimize the energy. It can be used to control the lighting or air conditioning of an area. An example is the library which can be well illuminated with many lamps. When people are not present at a reading place, the lighting can be made OFF and when they are present, the lighting is made ON by using a sensor to sense the environment condition example temperature, obstacle etc. All these ...

  9. Ventilator associated pneumonia or ventilator induced pneumonia.

    Science.gov (United States)

    Khan, Zahid Hussain; Ceriana, Piero; Donner, Claudio F

    2017-01-01

    Ventilator associated pneumonia currently in vogue seems to have some pitfalls as far as the nomenclature is concerned and thus it imparts an erroneous impression to the reader. As the driving force is in fact the ventilator, the phraseology should preferably be changed to ventilator induced pneumonia to convey the in depth meaning of the term thus evading the terminology currently in practice. A new and emerging paradigm dealing with all side effects of mechanical ventilation can be helpful to solve this etymological conflict.

  10. Laboratory study of subjective perceptions to low temperature heating systems with exhaust ventilation in Nordic countries

    DEFF Research Database (Denmark)

    Jin, Quan; Simone, Angela; Olesen, Bjarne W.

    2017-01-01

    Given the global trends of rising energy demand and the increasing utilization of low-grade renewable energy, low-temperature heating systems can play key roles in improving building energy efficiency while providing a comfortable indoor environment. To meet the need to retrofit existing buildings...

  11. Laboratory study of subjective perceptions to low temperature heating systems with exhaust ventilation in Nordic countries

    DEFF Research Database (Denmark)

    Jin, Quan; Simone, Angela; Olesen, Bjarne W.

    2017-01-01

    Given the global trends of rising energy demand and the increasing utilization of low-grade renewable energy, low-temperature heating systems can play key roles in improving building energy efficiency while providing a comfortable indoor environment. To meet the need to retrofit existing building...

  12. SY Tank Farm ventilation isolation option risk assessment report

    Energy Technology Data Exchange (ETDEWEB)

    Powers, T.B.; Morales, S.D.

    1994-03-01

    The safety of the 241-SY Tank Farm ventilation system has been under extensive scrutiny due to safety concerns associated with tank 101-SY. Hydrogen and other gases are generated and trapped in the waste below the liquid surface. Periodically, these gases are released into the dome space and vented through the exhaust system. This attention to the ventilation system has resulted in the development of several alternative ventilation system designs. The ventilation system provides the primary means of mitigation of accidents associated with flammable gases. This report provides an assessment of various alternatives ventilation system designs.

  13. Decreased respiratory system compliance on the sixth day of mechanical ventilation is a predictor of death in patients with established acute lung injury.

    Science.gov (United States)

    Seeley, Eric J; McAuley, Daniel F; Eisner, Mark; Miletin, Michael; Zhuo, Hanjing; Matthay, Michael A; Kallet, Richard H

    2011-04-22

    Multiple studies have identified single variables or composite scores that help risk stratify patients at the time of acute lung injury (ALI) diagnosis. However, few studies have addressed the important question of how changes in pulmonary physiologic variables might predict mortality in patients during the subacute or chronic phases of ALI. We studied pulmonary physiologic variables, including respiratory system compliance, P/F ratio and oxygenation index, in a cohort of patients with ALI who survived more than 6 days of mechanical ventilation to see if changes in these variables were predictive of death and whether they are informative about the pathophysiology of subacute ALI. Ninety-three patients with ALI who were mechanically ventilated for more than 6 days were enrolled in this prospective cohort study. Patients were enrolled at two medical centers in the US, a county hospital and a large academic center. Bivariate analyses were used to identify pulmonary physiologic predictors of death during the first 6 days of mechanical ventilation. Predictors on day 1, day 6 and the changes between day 1 and day 6 were compared in a multivariate logistic regression model. The overall mortality was 35%. In multivariate analysis, the PaO2/FiO2 (OR 2.09, p lung injury. In addition, a decrease in respiratory system compliance between days 1 and days 6 (OR 2.14, p ventilation were associated with increased mortality in multivariate analysis of this cohort of patients with ALI. We suggest that decreased respiratory system compliance may identify a subset of patients who have persistent pulmonary edema, atelectasis or the fibroproliferative sequelae of ALI and thus are less likely to survive their hospitalization.

  14. The ability of hospital ventilation systems to filter Aspergillus and other fungi following a building implosion.

    Science.gov (United States)

    Srinivasan, Arjun; Beck, Christopher; Buckley, Timothy; Geyh, Allison; Bova, Greg; Merz, William; Perl, Trish M

    2002-09-01

    To assess the ability of hospital air handling systems to filter Aspergillus, other fungi, and particles following the implosion of an adjacent building; to measure the quantity and persistence of airborne fungi and particles at varying distances during a building implosion; and to determine whether manipulating air systems based on the movement of the dust cloud would be an effective strategy for managing the impact of the implosion. Air sampling study. A 976-bed teaching hospital in Baltimore, Maryland. Single-stage impactors and particle counters were placed at outdoor sites 100, 200, and 400 m from the implosion and in five locations in the hospital: two oncology floors, the human immunodeficiency virus unit, the cardiac surgical intensive care unit, and the ophthalmology unit. Air handling systems would operate normally unless the cloud approached the hospital. Wind carried the bulk of the cloud away from the hospital. Aspergillus counts rose more than tenfold at outdoor locations up to 200 m from the implosion, but did not increase at 400 m. Total fungal counts rose more than sixfold at 100 and 200 m and twofold at 400 m. Similar to Aspergillus, particle counts rose several-fold following the implosion at 100 and 200 m, but did not rise at 400 m. No increases in any fungi or particles were measured at indoor locations. Reacting to the movement of the cloud was effective, because normal operation of the hospital air handling systems was able to accommodate the modest increase in Aspergillus, other fungi, and particles generated by the implosion. Aspergillus measurements were paralleled by particle counts.

  15. Prediction and Monitoring Systems of Creep-Fracture Behavior of 9Cr-1Mo Steels for Teactor Pressure Vessels

    Energy Technology Data Exchange (ETDEWEB)

    Potirniche, Gabriel [Univ. of Idaho, Moscow, ID (United States); Barlow, Fred D. [Univ. of Idaho, Moscow, ID (United States); Charit, Indrajit [Univ. of Idaho, Moscow, ID (United States); Rink, Karl [Univ. of Idaho, Moscow, ID (United States)

    2013-11-26

    A recent workshop on next-generation nuclear plant (NGNP) topics underscored the need for research studies on the creep fracture behavior of two materials under consideration for reactor pressure vessel (RPV) applications: 9Cr-1Mo and SA-5XX steels. This research project will provide a fundamental understanding of creep fracture behavior of modified 9Cr-1Mo steel welds for through modeling and experimentation and will recommend a design for an RPV structural health monitoring system. Following are the specific objectives of this research project: Characterize metallurgical degradation in welded modified 9Cr-1Mo steel resulting from aging processes and creep service conditions; Perform creep tests and characterize the mechanisms of creep fracture process; Quantify how the microstructure degradation controls the creep strength of welded steel specimens; Perform finite element (FE) simulations using polycrystal plasticity to understand how grain texture affects the creep fracture properties of welds; Develop a microstructure-based creep fracture model to estimate RPVs service life; Manufacture small, prototypic, cylindrical pressure vessels, subject them to degradation by aging, and measure their leak rates; Simulate damage evolution in creep specimens by FE analyses; Develop a model that correlates gas leak rates from welded pressure vessels with the amount of microstructural damage; Perform large-scale FE simulations with a realistic microstructure to evaluate RPV performance at elevated temperatures and creep strength; Develop a fracture model for the structural integrity of RPVs subjected to creep loads; and Develop a plan for a non-destructive structural health monitoring technique and damage detection device for RPVs.

  16. Analysis of energy management for heating, ventilating and air-conditioning systems

    Directory of Open Access Journals (Sweden)

    Mohamed Elhelw

    2016-06-01

    Full Text Available In the office buildings, large energy is consumed due to poor thermal performance and low efficiencies of HVAC systems. A cooling load calculation is a basis for the design of building cooling systems. The current design methods are usually based on deterministic cooling loads, which are obtained by using design parameters. However, these parameters contain uncertainties, and they will be different from that used in the design calculation when the cooling system is put in use. The actual cooling load profile will deviate from that predicted in design. A modified bin method was used in this paper to optimize the energy efficiency ratio (EER. A design optimization method is proposed by considering uncertainties related to the cooling load calculation. Impacts caused by the uncertainties of seven factors are considered, including the outdoor weather conditions and internal heat sources. The cooling load distribution is analyzed. Comparison between the modified bin method and CLTD/SCL/CLF method is also conducted. With the distributions of their energy consumption, decision makers can select the optimal configuration based on quantified confidence. According to the economic benefits and energy efficiency ratio, using modified bin method will increase the overall energy efficiency ratio by 45.57%.

  17. Concentration Distribution in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Pedersen, D. N.; Nielsen, Peter Vilhelm

    2001-01-01

    Today there is an increasing focus on the importance of a proper ventilation system to obtain good working conditions in the term of air and thermal quality to ensure high productivity. Different ventilation principles are used, e.g., mixing ventilation and displacement ventilation. In order....... Full scale experiments along with a breathing thermal manikin (BTM) have been used. The results show that the location of the sources is of great importance, just as well as temperature differences. Furthermore, the concentration in the breathing zone showed large differences throughout the room....

  18. Sleep and Mechanical Ventilation in Critical Care.

    Science.gov (United States)

    Blissitt, Patricia A

    2016-06-01

    Sleep disturbances in critically ill mechanically ventilated patients are common. Although many factors may potentially contribute to sleep loss in critical care, issues around mechanical ventilation are among the more complex. Sleep deprivation has systemic effects that may prolong the need for mechanical ventilation and length of stay in critical care and result in worse outcomes. This article provides a brief review of the physiology of sleep, physiologic changes in breathing associated with sleep, and the impact of mechanical ventilation on sleep. A summary of the issues regarding research studies to date is also included. Recommendations for the critical care nurse are provided. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Concentration Distribution in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Pedersen, D.N.; Nielsen, Peter V.

    2001-01-01

    Today there is an increasing focus on the importance of a proper ventilation system to obtain good working conditions in the term of air and thermal quality to ensure high productivity. Different ventilation principles are used, e.g., mixing ventilation and displacement ventilation. In order...... that the air is fully mixed. The objective of this work is to determine the influence of the location of a pollutant, temperature differences and whether the room is furnished or not. It is also investigated if it is sufficient to determine the mean concentration in the room to determine the personal exposure...

  20. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    CERN Document Server

    2012-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre