WorldWideScience

Sample records for vessel microport technique

  1. Processing and analysis techniques involving in-vessel material generation

    Science.gov (United States)

    Schabron, John F [Laramie, WY; Rovani, Jr., Joseph F.

    2011-01-25

    In at least one embodiment, the inventive technology relates to in-vessel generation of a material from a solution of interest as part of a processing and/or analysis operation. Preferred embodiments of the in-vessel material generation (e.g., in-vessel solid material generation) include precipitation; in certain embodiments, analysis and/or processing of the solution of interest may include dissolution of the material, perhaps as part of a successive dissolution protocol using solvents of increasing ability to dissolve. Applications include, but are by no means limited to estimation of a coking onset and solution (e.g., oil) fractionating.

  2. AN EFFICIENT TECHNIQUE FOR RETINAL VESSEL SEGMENTATION AND DENOISING USING MODIFIED ISODATA AND CLAHE

    Directory of Open Access Journals (Sweden)

    Khan Bahadar Khan

    2016-11-01

    Full Text Available Retinal damage caused due to complications of diabetes is known as Diabetic Retinopathy (DR. In this case, the vision is obscured due to the damage of retinal tinny blood vessels of the retina. These tinny blood vessels may cause leakage which affect the vision and can lead to complete blindness. Identification of these new retinal vessels and their structure is essential for analysis of DR. Automatic blood vessels segmentation plays a significant role to assist subsequent automatic methodologies that aid to such analysis. In literature most of the people have used computationally hungry a strong preprocessing steps followed by a simple thresholding and post processing, But in our proposed technique we utilize an arrangement of  light pre-processing which consists of Contrast Limited Adaptive Histogram Equalization (CLAHE for contrast enhancement, a difference image of green channel from its Gaussian blur filtered image to remove local noise or geometrical object, Modified Iterative Self Organizing Data Analysis Technique (MISODATA for segmentation of vessel and non-vessel pixels based on global and local thresholding, and a strong  post processing using region properties (area, eccentricity to eliminate the unwanted region/segment, non-vessel pixels and noise that never been used to reject misclassified foreground pixels. The strategy is tested on the publically accessible DRIVE (Digital Retinal Images for Vessel Extraction and STARE (STructured Analysis of the REtina databases. The performance of proposed technique is assessed comprehensively and the acquired accuracy, robustness, low complexity and high efficiency and very less computational time that make the method an efficient tool for automatic retinal image analysis. Proposed technique perform well as compared to the existing strategies on the online available databases in term of accuracy, sensitivity, specificity, false positive rate, true positive rate and area under receiver

  3. Extraction of Blood Vessels in Retinal Images Using Four Different Techniques

    Directory of Open Access Journals (Sweden)

    Asloob Ahmad Mudassar

    2013-01-01

    Full Text Available A variety of blood vessel extraction (BVE techniques exist in the literature, but they do not always lead to acceptable solutions especially in the presence of anomalies where the reported work is limited. Four techniques are presented for BVE: (1 BVE using Image Line Cross-Sections (ILCS, (2 BVE using Edge Enhancement and Edge Detection (EEED, (3 BVE using Modified Matched Filtering (MMF, and (4 BVE using Continuation Algorithm (CA. These four techniques have been designed especially for abnormal retinal images containing low vessel contrasts, drusen, exudates, and other artifacts. The four techniques were applied to 30 abnormal retinal images, and the success rate was found to be (95 to 99% for CA, (88–91% for EEED, (80–85% for MMF, and (74–78% for ILCS. Application of these four techniques to 105 normal retinal images gave improved results: (99-100% for CA, (96–98% for EEED, (94-95% for MMF, and (88–93% for ILCS. Investigations revealed that the four techniques in the order of increasing performance could be arranged as ILCS, MMF, EEED, and CA. Here we demonstrate these four techniques for abnormal retinal images only. ILCS, EEED, and CA are novel additions whereas MMF is an improved and modified version of an existing matched filtering technique. CA is a promising technique.

  4. Generic technique to grow III-V semiconductor nanowires in a closed glass vessel

    Directory of Open Access Journals (Sweden)

    Kan Li

    2016-06-01

    Full Text Available Crystalline III-V semiconductor nanowires have great potential in fabrication of nanodevices for applications in nanoelectronics and optoelectronics, and for studies of novel physical phenomena. Sophisticated epitaxy techniques with precisely controlled growth conditions are often used to prepare high quality III-V nanowires. The growth process and cost of these experiments are therefore dedicated and very high. Here, we report a simple but generic method to synthesize III-V nanowires with high crystal quality. The technique employs a closed evacuated tube vessel with a small tube carrier containing a solid source of materials and another small tube carrier containing a growth substrate inside. The growth of nanowires is achieved after heating the closed vessel in a furnace to a preset high temperature and then cooling it down naturally to room temperature. The technique has been employed to grow InAs, GaAs, and GaSb nanowires on Si/SiO2 substrates. The as-grown nanowires are analyzed by SEM, TEM and Raman spectroscopy and the results show that the nanowires are high quality zincblende single crystals. No particular condition needs to be adjusted and controlled in the experiments. This technique provides a convenient way of synthesis of III-V semiconductor nanowires with high material quality for a wide range of applications.

  5. Subadventitial techniques for chronic total occlusion percutaneous coronary intervention: The concept of "vessel architecture".

    Science.gov (United States)

    Azzalini, Lorenzo; Carlino, Mauro; Brilakis, Emmanouil S; Vo, Minh; Rinfret, Stéphane; Uretsky, Barry F; Karmpaliotis, Dimitri; Colombo, Antonio

    2017-03-17

    Despite improvements in guidewire technologies, the traditional antegrade wire escalation approach to chronic total occlusion (CTO) recanalization is successful in only 60-80% of selected cases. In particular, long, calcified, and tortuous occlusions are less successfully approached with a true-to-true lumen approach. Frequently, the guidewire tracks into the subadventitial space, with no guarantee of distal re-entry into the true lumen. The ability to manage the subadventitial space has been a key step in the tremendous improvement in success rates of contemporary CTO percutaneous coronary intervention (PCI), whether operating antegradely or retrogradely. A modern approach to CTO PCI involves understanding the concept of "vessel architecture," which is based on the distinction between coronary structures (occlusive plaque, comprising the disrupted intima and media, and the outer adventitia) and extravascular space. The vessel architecture represents a safe work environment for guidewire and device manipulation. This review provides an anatomy-based description of the concept of vessel architecture, along with a historical perspective of subadventitial techniques for CTO PCI, and outcome data of CTO PCI utilizing the subadventitial space. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  6. Bolted Ribs Analysis for the ITER Vacuum Vessel using Finite Element Submodelling Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Zarzalejos, José María, E-mail: jose.zarzalejos@ext.f4e.europa.eu [External at F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019, Barcelona (Spain); Fernández, Elena; Caixas, Joan; Bayón, Angel [F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019, Barcelona (Spain); Polo, Joaquín [Iberdrola Ingeniería y Construcción, Avenida de Manoteras 20, 28050 Madrid (Spain); Guirao, Julio [Numerical Analysis Technologies, S L., Marqués de San Esteban 52, Entlo, 33209 Gijon (Spain); García Cid, Javier [Iberdrola Ingeniería y Construcción, Avenida de Manoteras 20, 28050 Madrid (Spain); Rodríguez, Eduardo [Mechanical Engineering Department EPSIG, University of Oviedo, Gijon (Spain)

    2014-10-15

    Highlights: • The ITER Vacuum Vessel Bolted Ribs assemblies are modelled using Finite Elements. • Finite Element submodelling techniques are used. • Stress results are obtained for all the assemblies and a post-processing is performed. • All the elements of the assemblies are compliant with the regulatory provisions. • Submodelling is a time-efficient solution to verify the structural integrity of this type of structures. - Abstract: The ITER Vacuum Vessel (VV) primary function is to enclose the plasmas produced by the ITER Tokamak. Since it acts as the first radiological barrier of the plasma, it is classified as a class 2 welded box structure, according to RCC-MR 2007. The VV is made of an inner and an outer D-shape, 60 mm-thick double shell connected through thick massive bars (housings) and toroidal and poloidal structural stiffening ribs. In order to provide neutronic shielding to the ex-vessel components, the space between shells is filled with borated steel plates, called In-Wall Shielding (IWS) blocks, and water. In general, these blocks are connected to the IWS ribs which are connected to adjacent housings. The development of a Finite Element model of the ITER VV including all its components in detail is unaffordable from the computational point of view due to the large number of degrees of freedom it would require. This limitation can be overcome by using submodelling techniques to simulate the behaviour of the bolted ribs assemblies. Submodelling is a Finite Element technique which allows getting more accurate results in a given region of a coarse model by generating an independent, finer model of the region under study. In this paper, the methodology and several simulations of the VV bolted ribs assemblies using submodelling techniques are presented. A stress assessment has been performed for the elements involved in the assembly considering possible types of failure and including stress classification and categorization techniques to analyse

  7. Virtual cisternoscopy of intracranial vessels: a novel visualization technique using virtual reality.

    Science.gov (United States)

    Fellner, F; Blank, M; Fellner, C; Böhm-Jurkovic, H; Bautz, W; Kalender, W A

    1998-11-01

    This paper introduces a different visualization method which we call "virtual cisternoscopy" using 3D MRA data sets. Virtual cisternoscopy uses well known tools, such as perspective volume rendering (pVR), fly-through techniques, and interactive visualization and combines them to a new approach featuring motion to resolve spatial relationships of intracranial vessels and vascular malformations. With a dedicated flight protocol extraluminal topography of intracranial arteries was analyzed using pVR. For evaluation of difficult vascular malformations extraluminal views are necessary. Therefore, movies of pVR views were produced simulating virtual tracks of neurosurgical flexible endoscopes, by flying around the intracranial vessels and vascular malformations within the cisterns. Endoluminal views were acquired additionally for precise evaluation of cases with complex vessel topography. Two healthy volunteers and three patients were examined. Comparing MIP and pVR images relevant advantages of pVR were found, such as depth information, perspective, lighting, and color. In contrast to MIP and source images of the MRA data set, virtual cisternoscopy of an aneurysm of the left middle cerebral artery demonstrated clearly an early origin of an artery in the region of the aneurysm neck/sac. In this case only virtual cisternoscopy led to the correct therapeutical decision. In a newborn, the type of a vein of Galen aneurysmal malformation could only be evaluated reliably by means of virtual cisternoscopy. The third case of a patient with a clipped aneurysm was evaluated more easily with virtual cisternoscopy than with DSA. In conclusion, virtual cisternoscopy may improve the pretherapeutic visualization of intracranial vascular malformations.

  8. "Snare-Ride": A Bailout Technique to Catheterize Target Vessels With Unfriendly Anatomy in Branched Endovascular Aortic Repair.

    Science.gov (United States)

    Ferreira, Marcelo; Katsargyris, Athanasios; Rodrigues, Eduardo; Ferreira, Diego; Cunha, Rodrigo; Bicalho, Guilherme; Oderich, Gustavo; Verhoeven, Eric L G

    2017-08-01

    To describe a novel endovascular bailout technique for successful completion of target vessel stenting during branched stent-graft repair of thoracoabdominal aortic aneurysms (TAAA) after encountering difficulties with standard catheterization techniques. Technical difficulties when using fenestrated and branched grafts should be expected, especially in difficult anatomy or when an off-the-shelf device (eg, standard 4-branch device) is used that does not perfectly "match" the anatomy. The "snare-ride technique" facilitates antegrade transaxillary side branch catheterization and stent placement during TAAA branched grafting using a snare via a transfemoral approach. The branch of the graft is catheterized from an axillary access. The respective target vessel is then catheterized via a femoral access. An Indy snare is advanced over the transfemoral wire and positioned near the entrance of the target vessel. The transaxillary wire inside the branch of the graft is then advanced, snared, and pushed inside the target vessel with the snare. The procedure is thereafter continued with antegrade bridging of the target vessel in routine fashion. The snare-ride technique can be a useful maneuver to catheterize target vessels with difficult anatomy in TAAA branched stent-graft repair. Early experience shows safety and feasibility.

  9. Visualization of simulated small vessels on computed tomography using a model-based iterative reconstruction technique.

    Science.gov (United States)

    Higaki, Toru; Tatsugami, Fuminari; Fujioka, Chikako; Sakane, Hiroaki; Nakamura, Yuko; Baba, Yasutaka; Iida, Makoto; Awai, Kazuo

    2017-08-01

    This article describes a quantitative evaluation of visualizing small vessels using several image reconstruction methods in computed tomography. Simulated vessels with diameters of 1-6 mm made by 3D printer was scanned using 320-row detector computed tomography (CT). Hybrid iterative reconstruction (hybrid IR) and model-based iterative reconstruction (MBIR) were performed for the image reconstruction.

  10. Visualization of simulated small vessels on computed tomography using a model-based iterative reconstruction technique

    OpenAIRE

    Toru Higaki; Fuminari Tatsugami; Chikako Fujioka; Hiroaki Sakane; Yuko Nakamura; Yasutaka Baba; Makoto Iida; Kazuo Awai

    2017-01-01

    This article describes a quantitative evaluation of visualizing small vessels using several image reconstruction methods in computed tomography. Simulated vessels with diameters of 1?6?mm made by 3D printer was scanned using 320-row detector computed tomography (CT). Hybrid iterative reconstruction (hybrid IR) and model-based iterative reconstruction (MBIR) were performed for the image reconstruction.

  11. Visualization of simulated small vessels on computed tomography using a model-based iterative reconstruction technique

    Directory of Open Access Journals (Sweden)

    Toru Higaki

    2017-08-01

    Full Text Available This article describes a quantitative evaluation of visualizing small vessels using several image reconstruction methods in computed tomography. Simulated vessels with diameters of 1–6 mm made by 3D printer was scanned using 320-row detector computed tomography (CT. Hybrid iterative reconstruction (hybrid IR and model-based iterative reconstruction (MBIR were performed for the image reconstruction.

  12. Techniques for transcatheter recanalization of completely occluded vessels and pathways in patients with congenital heart disease

    Directory of Open Access Journals (Sweden)

    Latson Larry

    2010-01-01

    Full Text Available Occlusions of major vessels in patients with congenital heart disease may occur due to a variety of factors. These occlusions are often felt to be best addressed surgically; however, we and others have been successful in recanalizing most of these vessels in the catheterization laboratory. Most of these patients will require multiple procedures in the catheterization laboratory to ensure vessel patency and to facilitate vessel growth. Physicians performing the procedure should have a thorough understanding of the anatomic considerations for the intended procedure and have access to a variety of devices and equipment to optimize the result of the procedure. In this article, we review some of the technical aspects that are vital for the success of the procedure.

  13. Leveraging Multiscale Hessian-Based Enhancement With a Novel Exudate Inpainting Technique for Retinal Vessel Segmentation.

    Science.gov (United States)

    Annunziata, Roberto; Garzelli, Andrea; Ballerini, Lucia; Mecocci, Alessandro; Trucco, Emanuele

    2016-07-01

    Accurate vessel detection in retinal images is an important and difficult task. Detection is made more challenging in pathological images with the presence of exudates and other abnormalities. In this paper, we present a new unsupervised vessel segmentation approach to address this problem. A novel inpainting filter, called neighborhood estimator before filling, is proposed to inpaint exudates in a way that nearby false positives are significantly reduced during vessel enhancement. Retinal vascular enhancement is achieved with a multiple-scale Hessian approach. Experimental results show that the proposed vessel segmentation method outperforms state-of-the-art algorithms reported in the recent literature, both visually and in terms of quantitative measurements, with overall mean accuracy of 95.62% on the STARE dataset and 95.81% on the HRF dataset.

  14. Implementation of 3D-Imaging technique for visual testing in a nuclear reactor pressure vessel

    OpenAIRE

    Tanco, André

    2014-01-01

    This master thesis has been performed by request of Dekra Industrial AB. Dekra Industrial AB is a Swedish subsidiary company of the German company Dekra and works for example with safety inspections within the nuclear power industry. The inspections performed by the company are often non-destructive testing (NDT) such as visual inspections of nuclear reactor pressure vessels. The inspection methods used today are considered to be further developed and there is a strong demand of improving the...

  15. Low Background Techniques And Experimental Challenges For Borexino And Its Nylon Vessels

    CERN Document Server

    Pocar, A P

    2003-01-01

    Borexino is an experiment for low energy (<1 MeV) solar neutrino spectroscopy approaching completion at the underground Gran Sasso laboratories in Italy. It is specifically designed to measure in real time the flux of mono-energetic [/berillium] neutrinos produced by fusion reactions in the Sun. Its 300-ton liquid scintillator target is contained in an 8.5 meter diameter nylon inner vessel (IV) and is surrounded by 1000 tons of buffer fluid. A second, 11.5 meter diameter concentric nylon outer vessel (OV) around the IV serves as a barrier for radon emanated at the periphery of the detector. Borexino requires unprecedented low levels of radioactive impurities to be a success (∼1 background event/day in the central 100-tons of scintillator). The IV, which is in direct contact with the scintillator, also has to meet extremely stringent radioactive and cleanliness requirements. Intrinsic levels ∼10 −12 g/g for U and Th and ∼10−8 g/g for K are needed. The vessels,...

  16. Five cases of iatrogenic foreign body in the heart and/or great vessels. Retrieved percutaneously by interventional radiological technique

    Energy Technology Data Exchange (ETDEWEB)

    Uda, Mitsunobu; Sawada, Satoshi; Oshima, Taichi; Kato, Tsutomu; Harima, Keizo; Tanaka, Yoshimasa

    1988-07-01

    5 cases of iatrogenic foreign body in the heart and/or great vessels were reported. We retrieved these foreign bodies (broken catheters) percutaneously by interventional radiologic technique. We detected foreign bodies by chest X-ray film, echogram and DSA. Echogram was useful in the case of radiopague foreign bodies. DSA revealed foreign bodies more clearly than chest X-ray films. We used multipurpose grasping forceps and loop snare combined with pigtail catheter to retrieve. We could retrieve foreign bodies percutaneously in all cases.

  17. Comparison of a Vessel Sealing System with a Conventional Technique in Hemorrhoidectomy

    Directory of Open Access Journals (Sweden)

    Serkan Teksöz

    2011-06-01

    Full Text Available Objective: Milligan-Morgan, Park and Ferguson hemorrhoidectomy procedures are the ones most frequently used for the surgical treatment of hemorrhoidal disease. Attempts to modify these conventional approaches are made by using different techniques or tools to decrease blood loss, and reduce operating time and postoperative analgesic requirement. In this prospective randomized trial, the conventional Ferguson hemorrhoidectomy method is compared with the LigaSure® hemorrhoidectomy according to various criteria. Material and Methods: Forty patients who had grade 3-4 hemorrhoidal disease were randomly divided into two equal groups: the Ferguson Hemorrhoidectomy (n=20 and the LigaSure® hemorrhoidectomy (n=20. Operating time, demographic data, intraoperative and postoperative complications, postoperative pain, return of bowel movements and postoperative hospital stay were evaluated. The visual analogue score was used for the evaluation of pain on the first postoperative day. The patients have been followed up for at least 19 months. Results: The pain score, blood loss and operating time were significantly reduced in the LigaSure® hemorrhoidectomy group. Conclusion: LigaSure® hemorrhoidectomy is safe and feasible for the surgeon, and more comfortable than classical surgery for the patient.

  18. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  19. Effective and efficient lymphaticovenular anastomosis using preoperative ultrasound detection technique of lymphatic vessels in lower extremity lymphedema.

    Science.gov (United States)

    Hayashi, Akitatsu; Hayashi, Nobuko; Yoshimatsu, Hidehiko; Yamamoto, Takumi

    2017-10-23

    Identification of functional lymphatic vessels and localization of lymphatic vessels are important for lymphaticovenular anastomosis (LVA). Indocyanine green (ICG) lymphography is useful for localization of superficial lymphatic vessels where dermal backflow is not observed, but not for lymphatic vessels in deep layer or where dermal backflow is observed. Ultrasound has been applied in LVA and is considered useful for localization of lymphatic vessels with ICG lymphography cannot be visualized. Fifty-five secondary lower extremity lymphedema (LEL) patients who underwent LVA were classified into two groups, ultrasound-detection-of-lymphatic group (US group, n = 29) and non-ultrasound-detection-of-lymphatic group (non-US group, n = 26), and assessed. Sensitivity and specificity to detect lymphatic vessel were evaluated in US group. Intraoperative findings, required time for dissecting lymphatic vessels and veins, length of skin incision, and postoperative lymphedematous volume reduction were compared between the groups. Lymphatic vessels were detected in all incisions in both groups. LVA resulted in 232 anastomoses in US group and 210 anastomoses in non-US group. Sensitivity and specificity of ultrasound for detection of lymphatic vessels were 88.2% and 92.7%, respectively. Diameter of lymphatic vessels found in US group was significantly larger than that in non-US group (0.66 ± 0.18 vs 0.45 ± 0.20 mm; P = 0.042). Time required for dissecting lymphatic vessels and veins in US group was shorter than that in non-US group (9.2 ± 1.7 vs 14.7 ± 2.4 min; P = 0.026). LEL index reduction was significantly greater in US group than that in non-US group (26.7 ± 13.6 vs 7.8 ± 11.3; P = 0.031). Ultrasound-guided detection of lymphatic vessels for lymphedema was performed with high precision, and allows easier and more effective LVA surgery. © 2017 Wiley Periodicals, Inc.

  20. A contrast enhancement and scanning techniques for CT angiography of head and neck. One phase injection method for simultaneous imaging of vessels and tumor

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Yasuhiko; Indo, Hiroko; Noikura, Takenori [Kagoshima Univ. (Japan). Dental School

    1999-09-01

    We report on a method of CT-Angiography useful for examining lesion of the head and neck using three-dimensional images and measured CT value. This study focused on some of the important blood vessels in the head and neck. The aim of this method was to obtain high-contrast enhancement for both vessels and tumors at same time. A total amount of 100 ml nonionic contrast media (Omnipaque 240, 240 mg iodine per milliliter, Daiichi seiyaku, Tokyo, Japan) was injected intravenously with a flow of 1.5 ml/sec. Spiral scans, 24 rotations with 24 seconds, were started at a time when remaining amount of contrast media had become 30 to 20 ml. All CT scans were performed using double speed spiral scan technique with a slice thickness of 2 to 3 mm and table speeds from 3 to 5 mm/rotation. The patients populations consisted of 9 men and 6 women who ranged in age from 37 to 85 years. Sixteen CT-angiography were performed according to this method. Mean CT values of major blood vessels were measured in order to find out threshold at the level of submandibular gland in 13 examinations for 12 subjects. Important vessels like the common, internal, and the external artery, internal and external jugular vein were clearly visible in all subjects. Three dimensional images of these vessels could also be reconstructed for 15 of the subjects. Mean CT values were 211 Hounsfield units (HU) and 209 HU for the right and left internal carotid artery, respectively, and 204 HU and 206 HU for the right and left external carotid artery, respectively. Mean CT values for right and left internal jugular vein were 195 HU and 194 HU respectively. Measured CT values at each important blood vessels showed this method could yields acceptable enhancements. Good enhancement effect of tumor and blood vessels in the same scan seems to be mutually incompatible. One very important trade-off is the early enhancement effect at blood vessels versus the late enhancement effect at tumors. The other important trade

  1. The effects of 595- and 1,064-nm lasers on rooster comb blood vessels using dual-wavelength and multipulse techniques.

    Science.gov (United States)

    Li, Guang; Sun, Jianfang; Shao, Xuebao; Sang, Honggui; Zhou, Zhanchao

    2011-10-01

    After laser irradiation, hemoglobin can transform into methemoglobin and coagulum, which have high absorptivity of near-infrared light. Sequential irradiation with 595 nm and 1,064 nm may be more effective than single wavelength to decrease residual vessel number in rooster combs. Six protocols (single pulse with 595 nm, double pulse with 595 nm, single pulse with 1,064 nm, double pulse with 1,064 nm, sequential irradiation with 595 nm and 1,064 nm (multiplex), and a blank control group) were used to compare the effects of sequential and single-wavelength irradiation on reducing residual vessel number, as well as the epidermal side effects, in the rooster comb. Different treatment techniques were applied to the same comb, at the same time. The treated areas of the epidermis and the residual vessels were observed using an optical microscope. All five techniques were effective in decreasing the number of residual vessels in the comb, and the side effects on the epidermis were similar for all. Considering the selectivity of the 595-nm laser and the rich melanin in the human epidermis, the dual-wavelength laser has a distinct advantage in treating vascular lesions. The authors have indicated no significant interest with commercial supporters. © 2011 by the American Society for Dermatologic Surgery, Inc.

  2. Microbubble Void Imaging: A Non-invasive Technique for Flow Visualisation and Quantification of Mixing in Large Vessels Using Plane Wave Ultrasound and Controlled Microbubble Contrast Agent Destruction.

    Science.gov (United States)

    Leow, Chee Hau; Iori, Francesco; Corbett, Richard; Duncan, Neill; Caro, Colin; Vincent, Peter; Tang, Meng-Xing

    2015-11-01

    There is increasing recognition of the influence of the flow field on the physiology of blood vessels and their development of pathology. Preliminary work is reported on a novel non-invasive technique, microbubble void imaging, which is based on ultrasound and controlled destruction of microbubble contrast agents, permitting flow visualisation and quantification of flow-induced mixing in large vessels. The generation of microbubble voids can be controlled both spatially and temporally using ultrasound parameters within the safety limits. Three different model vessel geometries-straight, planar-curved and helical-with known effects on the flow field and mixing were chosen to evaluate the technique. A high-frame-rate ultrasound system with plane wave transmission was used to acquire the contrast-enhanced ultrasound images, and an entropy measure was calculated to quantify mixing. The experimental results were cross-compared between the different geometries and with computational fluid dynamics. The results indicated that the technique is able to quantify the degree of mixing within the different configurations, with a helical geometry generating the greatest mixing, and a straight geometry, the lowest. There is a high level of concordance between the computational fluid dynamics and experimental results. The technique could also serve as a flow visualisation tool. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  3. 4D Flow of the Whole Heart and Great Vessels Using a Real Time Self Respiratory Gating Technique

    DEFF Research Database (Denmark)

    Uribe, Sergio; Beerbaum, Philipp; Sørensen, Thomas Sangild

    To evaluate the feasibility of a 4D-flow sequence of the whole heart and great vessel to retrospectively quantify blood flow within the entire heart. 4D-flow has been introduced as a means of acquiring anatomical and three-directional velocity information for all pixels within a 3D volume over...

  4. Evaluation of an improved technique for lumen path definition and lumen segmentation of atherosclerotic vessels in CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Velsen, Evert F.S. van; Niessen, Wiro J.; Meijering, Erik; Stokking, Rik [University Medical Center Rotterdam, Departments of Radiology and Medical Informatics, Biomedical Imaging Group Rotterdam, Erasmus MC, Rotterdam (Netherlands); Weert, Thomas T. de; Monye, Cecile de; Lugt, Aad van der [University Medical Center Rotterdam, Department of Radiology, Erasmus MC, Rotterdam (Netherlands)

    2007-07-15

    Vessel image analysis is crucial when considering therapeutical options for (cardio-) vascular diseases. Our method, VAMPIRE (Vascular Analysis using Multiscale Paths Inferred from Ridges and Edges), involves two parts: a user defines a start- and endpoint upon which a lumen path is automatically defined, and which is used for initialization; the automatic segmentation of the vessel lumen on computed tomographic angiography (CTA) images. Both parts are based on the detection of vessel-like structures by analyzing intensity, edge, and ridge information. A multi-observer evaluation study was performed to compare VAMPIRE with a conventional method on the CTA data of 15 patients with carotid artery stenosis. In addition to the start- and endpoint, the two radiologists required on average 2.5 (SD: 1.9) additional points to define a lumen path when using the conventional method, and 0.1 (SD: 0.3) when using VAMPIRE. The segmentation results were quantitatively evaluated using Similarity Indices, which were slightly lower between VAMPIRE and the two radiologists (respectively 0.90 and 0.88) compared with the Similarity Index between the radiologists (0.92). The evaluation shows that the improved definition of a lumen path requires minimal user interaction, and that using this path as initialization leads to good automatic lumen segmentation results. (orig.)

  5. Randomized comparison between provisional and routine kissing-balloon technique after main vessel crossover stenting for coronary bifurcation lesions.

    Science.gov (United States)

    Yamawaki, Masahiro; Fujita, Masaki; Sasaki, Shinya; Tsurugida, Masanori; Nanasato, Mamoru; Araki, Motoharu; Hirano, Keisuke; Ito, Yoshiaki; Tsukahara, Reiko; Muramatsu, Toshiya

    2017-04-11

    We compared the myocardial ischemic burden of provisional and routine final kissing-balloon inflation (FKI) with the 1-stent strategy using a second-generation drug-eluting stent for coronary bifurcation lesions (CBL). There are no established guidelines for side branch (SB) intervention after main vessel stenting. In total, 113 CBL patients were randomized to receive different SB intervention strategies: provisional-FKI group (n = 57; FKI only when SB flow was TIMI stress myocardial perfusion scintigraphy with (99m)Tc was performed after 8 months. The regional summed-difference score (r-SDS) was calculated according to the coronary territory. The primary endpoint included target vessel ischemia (TVI; r-SDS ≥ 2) at 8 months, whereas the clinical primary endpoint was major adverse cardiovascular events (MACE) at 3 years. The percent (%) myocardial ischemia (100 × SDS/68) was also calculated. At 8 months, TVI was identified in 11 and 4% in the provisional-FKI and routine-FKI groups, respectively (p = 0.226). SB-binary restenosis (48 vs. 4%, p 10% myocardial ischemia) was not observed in the target vessel in either group. Long-term cumulative MACE were similar between the groups (9 vs. 14%; p = 0.358). Provisional-FKI according to TIMI-SB flow grade led to similar and acceptable myocardial ischemia, in comparison with routine-FKI, which may contribute to the identical long-term follow-up.

  6. Particle Imaging Velocimetry Technique Development for Laboratory Measurement of Fracture Flow Inside a Pressure Vessel Using Neutron Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Polsky, Yarom [ORNL; Bingham, Philip R [ORNL; Bilheux, Hassina Z [ORNL; Carmichael, Justin R [ORNL

    2015-01-01

    This paper will describe recent progress made in developing neutron imaging based particle imaging velocimetry techniques for visualizing and quantifying flow structure through a high pressure flow cell with high temperature capability (up to 350 degrees C). This experimental capability has great potential for improving the understanding of flow through fractured systems in applications such as enhanced geothermal systems (EGS). For example, flow structure measurement can be used to develop and validate single phase flow models used for simulation, experimentally identify critical transition regions and their dependence on fracture features such as surface roughness, and study multiphase fluid behavior within fractured systems. The developed method involves the controlled injection of a high contrast fluid into a water flow stream to produce droplets that can be tracked using neutron radiography. A description of the experimental setup will be provided along with an overview of the algorithms used to automatically track droplets and relate them to the velocity gradient in the flow stream. Experimental results will be reported along with volume of fluids based simulation techniques used to model observed flow.

  7. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    by the research vessels RV Gaveshani and ORV Sagar Kanya are reported. The work carried out by the three charted ships is also recorded. A short note on cruise plans for the study of ferromanganese nodules is added...

  8. PCs and networking for oceanographic research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Desai, R.G.P.; Desa, E.; Vithayathil, G.

    This paper, first describes briefly the evolution of data acquisition techniques and different system implementation, on board research vessels. A data acquisition system being developed for a coastal research vessel is then described which is based...

  9. Pressure vessel design manual

    Energy Technology Data Exchange (ETDEWEB)

    Moss, D.R.

    1987-01-01

    The first section of the book covers types of loadings, failures, and stress theories, and how they apply to pressure vessels. The book delineates the procedures for designing typical components as well as those for designing large openings in cylindrical shells, ring girders, davits, platforms, bins and elevated tanks. The techniques for designing conical transitions, cone-cylinder intersections, intermediate heads, flat heads, and spherically dished covers are also described. The book covers the design of vessel supports subject to wind and seismic loads and one section is devoted to the five major ways of analyzing loads on shells and heads. Each procedure is detailed enough to size all welds, bolts, and plate thicknesses and to determine actual stresses.

  10. Use of a Temporary Shunt as a Salvage Technique for Distal Extremity Amputations Requiring Repair by Vessel Grafting during Critical Ischemia

    Directory of Open Access Journals (Sweden)

    Bilsev Ince

    2016-11-01

    Full Text Available BackgroundAlthough the use of temporary shunts in proximal extremity amputations has been reported, no study has described the use of temporary shunts in distal extremity amputations that require vein grafting. Moreover, the total volume of blood loss when temporary shunts are used has not been reported. The aim of this study was to investigate the applicability of a temporary shunt for distal extremity amputations requiring repair by vessel grafting with an ischemia time of >6 hours. This study also aimed to determine the total volume of blood loss when temporary shunts were used.MethodsPatients who underwent distal major extremity replantation and/or revascularization with a vessel graft and who experienced ischemia for 6–8 hours between 2013 and 2014 were included in the study. A 6-Fr suction catheter was cut to 5 cm in length after the infusion of heparin, and secured with a 5-0 silk suture between the distal and the proximal ends of the artery. While bleeding continued, the bones were shortened and fixed. After the complete restoration of circulation, the arterial shunt created using the catheter was also repaired with a vein graft.ResultsSix patients were included in this study. The mean duration of ischemia was 7.25 hours. The mean duration of suction catheter use during limb revascularization was 7 minutes. The mean transfusion volume was 7.5 units. No losses of the extremity were observed.ConclusionsThis procedure should be considered in distal extremity amputations requiring repair by vessel grafting during critical ischemia.

  11. Total ‘rib’-preservation technique of internal mammary vessel exposure for free flap breast reconstruction: A 5-year prospective cohort study and instructional video

    Directory of Open Access Journals (Sweden)

    Anais Rosich-Medina

    2015-09-01

    Discussion & conclusion: The total ‘rib’-preservation technique of IMV exposure is a safe, reliable and versatile method for microvascular breast reconstruction and should be considered as a valid alternative to the ‘rib’-sacrificing techniques.

  12. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  13. The Assessment and Validation of Mini-Compact Tension Test Specimen Geometry and Progress in Establishing Technique for Fracture Toughness Master Curves for Reactor Pressure Vessel Steels

    Energy Technology Data Exchange (ETDEWEB)

    Sokolov, Mikhail A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nanstad, Randy K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    Small specimens are playing the key role in evaluating properties of irradiated materials. The use of small specimens provides several advantages. Typically, only a small volume of material can be irradiated in a reactor at desirable conditions in terms of temperature, neutron flux, and neutron dose. A small volume of irradiated material may also allow for easier handling of specimens. Smaller specimens reduce the amount of radioactive material, minimizing personnel exposures and waste disposal. However, use of small specimens imposes a variety of challenges as well. These challenges are associated with proper accounting for size effects and transferability of small specimen data to the real structures of interest. Any fracture toughness specimen that can be made out of the broken halves of standard Charpy specimens may have exceptional utility for evaluation of reactor pressure vessels (RPVs) since it would allow one to determine and monitor directly actual fracture toughness instead of requiring indirect predictions using correlations established with impact data. The Charpy V-notch specimen is the most commonly used specimen geometry in surveillance programs. Assessment and validation of mini-CT specimen geometry has been performed on previously well characterized HSST Plate 13B, an A533B class 1 steel. It was shown that the fracture toughness transition temperature measured by these Mini-CT specimens is within the range of To values that were derived from various large fracture toughness specimens. Moreover, the scatter of the fracture toughness values measured by Mini-CT specimens perfectly follows the Weibull distribution function providing additional proof for validation of this geometry for the Master Curve evaluation of rector pressure vessel steels. Moreover, the International collaborative program has been developed to extend the assessment and validation efforts to irradiated weld metal. The program is underway and involves ORNL, CRIEPI, and EPRI.

  14. Analyzing Vessel Behavior Using Process Mining

    NARCIS (Netherlands)

    Maggi, F.M.; Mooij, A.J.; Aalst, W.M.P. van der

    2013-01-01

    In the maritime domain, electronic sensors such as AIS receivers and radars collect large amounts of data about the vessels in a certain geographical area. We investigate the use of process mining techniques for analyzing the behavior of the vessels based on these data. In the context of maritime

  15. BIOASSAY VESSEL FAILURE ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    Vormelker, P

    2008-09-22

    Two high-pressure bioassay vessels failed at the Savannah River Site during a microwave heating process for biosample testing. Improper installation of the thermal shield in the first failure caused the vessel to burst during microwave heating. The second vessel failure is attributed to overpressurization during a test run. Vessel failure appeared to initiate in the mold parting line, the thinnest cross-section of the octagonal vessel. No material flaws were found in the vessel that would impair its structural performance. Content weight should be minimized to reduce operating temperature and pressure. Outer vessel life is dependent on actual temperature exposure. Since thermal aging of the vessels can be detrimental to their performance, it was recommended that the vessels be used for a limited number of cycles to be determined by additional testing.

  16. [Anesthesia for the surgery of delayed postoperative stenosis in the pulmonary suture in children with corrected transposition of the great vessels with Jatene's technique].

    Science.gov (United States)

    Suán, C; Cerro, J; Ojeda, R; García-Perla, J L

    1996-11-01

    Any patient with congenital heart disease is at high risk for anesthesia no matter what surgical procedure is performed. Children undergoing D-transposition of the great arteries using Jatene's technique present stenosis of the pulmonary artery in 10-20% of cases and may require surgery to correct that or some other surgically caused anomally. In either case the children must be managed as patients with heart disease, with special attention to cardiovascular depression and rhythm abnormalities. We report the cases of two children who underwent D-transposition of the great arteries in the neonatal period using Jatene's anatomical technique. They were later anesthetized at ages 5 and 6 years to correct pulmonary suture stenosis. Recovery was good.

  17. Guam Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Guam. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  18. Florida Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Florida. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  19. Vessel Arrival Info - Legacy

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Vessel Arrival Info is a spreadsheet that gets filled out during the initial stage of the debriefing process by the debriefer. It contains vessel name, trip...

  20. ALICE HMPID Radiator Vessel

    CERN Multimedia

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  1. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  2. Maury Journals - German Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — German vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  3. Recent Advancements in Retinal Vessel Segmentation.

    Science.gov (United States)

    L Srinidhi, Chetan; Aparna, P; Rajan, Jeny

    2017-04-01

    Retinal vessel segmentation is a key step towards the accurate visualization, diagnosis, early treatment and surgery planning of ocular diseases. For the last two decades, a tremendous amount of research has been dedicated in developing automated methods for segmentation of blood vessels from retinal fundus images. Despite the fact, segmentation of retinal vessels still remains a challenging task due to the presence of abnormalities, varying size and shape of the vessels, non-uniform illumination and anatomical variability between subjects. In this paper, we carry out a systematic review of the most recent advancements in retinal vessel segmentation methods published in last five years. The objectives of this study are as follows: first, we discuss the most crucial preprocessing steps that are involved in accurate segmentation of vessels. Second, we review most recent state-of-the-art retinal vessel segmentation techniques which are classified into different categories based on their main principle. Third, we quantitatively analyse these methods in terms of its sensitivity, specificity, accuracy, area under the curve and discuss newly introduced performance metrics in current literature. Fourth, we discuss the advantages and limitations of the existing segmentation techniques. Finally, we provide an insight into active problems and possible future directions towards building successful computer-aided diagnostic system.

  4. PRESSURE-RESISTANT VESSEL

    NARCIS (Netherlands)

    Beukers, A.; De Jong, T.

    1997-01-01

    Abstract of WO 9717570 (A1) The invention is directed to a wheel-shaped pressure-resistant vessel for gaseous, liquid or liquefied material having a substantially rigid shape, said vessel comprising a substantially continuous shell of a fiber-reinforced resin having a central opening, an inner

  5. Containment vessel drain system

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  6. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  7. 2011 Passenger Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  8. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  9. 2013 Passenger Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  10. 2013 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  11. 2013 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  12. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  13. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  14. Maury Journals - US Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — U.S. vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  15. 2011 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  16. 2011 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  17. 2013 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  18. Coastal Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels that have been issued a Federal permit for the Gulf of Mexico reef fish,...

  19. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  20. Enhancing supply vessel safety

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    A supply-vessel bridge installation consists of a navigating bridge and a control position aft, from which operators control the ship when close to rigs or platforms, and operate winches and other loading equipment. The international Convention for Safety of I Ale at Sea (SOLAS) does not regulate the layout, so design varies to a large degree, often causing an imperfect working environment. As for other types of ships, more than half the offshore service vessel accidents at sea are caused by bridge system failures. A majority can be traced back to technical design, and operational errors. The research and development project NAUT-OSV is a response to the offshore industry's safety concerns. Analysis of 24 incidents involving contact or collision between supply vessels and offshore installations owned or operated by Norwegian companies indicated that failures in the bridge system were often the cause.

  1. Intracranial vessel wall imaging at 7.0 tesla MRI

    NARCIS (Netherlands)

    van der Kolk, A.G.

    2014-01-01

    Intracranial atherosclerosis is one of the main causes of ischemic stroke. Current conventional imaging techniques assessing intracranial arterial disease in vivo only visualize the vessel wall lumen instead of the pathological vessel wall itself. Therefore, not much is known about the imaging

  2. Thermal destruction of vessels with liquid upon heating

    Science.gov (United States)

    Zverev, V. G.; Goldin, V. D.; Svetashkov, A. A.

    2016-04-01

    A new engineering technique of calculating the heating and thermal destruction of vessels containing liquid under extreme thermal loading conditions is offered. The heating of the shell and the internal vessel volume is described on the basis of the thermodynamic approach. The pressure growth in a vessel is a result of gas heating and liquid evaporation. Stresses within the shell and its destruction conditions are determined, which allows predicting the critical time of destruction upon heating. The calculation and experimental data for pressure growth inside the vessel are in good agreement.

  3. GOLD PRESSURE VESSEL SEAL

    Science.gov (United States)

    Smith, A.E.

    1963-11-26

    An improved seal between the piston and die member of a piston-cylinder type pressure vessel is presented. A layer of gold, of sufficient thickness to provide an interference fit between the piston and die member, is plated on the contacting surface of at least one of the members. (AEC)

  4. Network of endocardial vessels.

    Science.gov (United States)

    Lee, Byung-Cheon; Kim, Hong Bae; Sung, Baeckkyoung; Kim, Ki Woo; Sohn, Jamin; Son, Boram; Chang, Byung-Joon; Soh, Kwang-Sup

    2011-01-01

    Although there have been reports on threadlike structures inside the heart, they have received little attention. We aimed to develop a method for observing such structures and to reveal their ultrastructures. An in situ staining method, which uses a series of procedures of 0.2-0.4% trypan blue spraying and washing, was applied to observe threadlike structures on the surfaces of endocardia. The threadlike structures were isolated and observed by using confocal laser scanning microscopy (CLSM) and transmission electron microscopy (TEM). Networks of endocardial vessels (20 μm in thickness) with expansions (40-100 μm in diameter) were visualized; they were movable on the endocardium of the bovine atrium and ventricle. CLSM showed that (1) rod-shaped nuclei were aligned along the longitudinal direction of the endocardial vessel and (2) there were many cells inside the expansion. TEM on the endocardial vessel revealed that (1) there existed multiple lumens (1-7 μm in diameter) and (2) the extracellular matrices mostly consisted of collagen fibers, which were aligned along the longitudinal direction of the endocardial vessel or were locally organized in reticular structures. We investigated the endocardial circulatory system in bovine cardiac chambers and its ultrastructures, such as nucleic distributions, microlumens, and collagenous extracellular matrices. Copyright © 2011 S. Karger AG, Basel.

  5. Pressurized Vessel Slurry Pumping

    Energy Technology Data Exchange (ETDEWEB)

    Pound, C.R.

    2001-09-17

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air.

  6. Computer Analysis of Eye Blood-Vessel Images

    Science.gov (United States)

    Wall, R. J.; White, B. S.

    1984-01-01

    Technique rapidly diagnoses diabetes mellitus. Photographs of "whites" of patients' eyes scanned by computerized image analyzer programmed to quantify density of small blood vessels in conjuctiva. Comparison with data base of known normal and diabetic patients facilitates rapid diagnosis.

  7. Detection of Blood Vessels in Retinal Fundus Images

    Directory of Open Access Journals (Sweden)

    Faraz Oloumi

    2014-07-01

    Full Text Available Detection of blood vessels in retinal fundus images is an important initial step in the development of systems for computer-aided diagnosis of pathologies of the eye. In this study, we perform multifeature analysis for the detection of blood vessels in retinal fundus images. The vessel detection techniques implemented include multiscale vesselness measures, Gabor filters, line operators, and matched filters. The selection of an appropriate threshold is crucial for accurate detection of retinal blood vessels. We evaluate an adaptive threshold selection method along with several others for this purpose. We also propose a postprocessing technique for removal of false-positive pixels around the optic nerve head. Values of the area under the receiver operating haracteristic curve of up to $0.961$ were obtained using the $20$ test images of the DRIVE database.

  8. Cholinergic innervation of human mesenteric lymphatic vessels.

    Science.gov (United States)

    D'Andrea, V; Bianchi, E; Taurone, S; Mignini, F; Cavallotti, C; Artico, M

    2013-11-01

    The cholinergic neurotransmission within the human mesenteric lymphatic vessels has been poorly studied. Therefore, our aim is to analyse the cholinergic nerve fibres of lymphatic vessels using the traditional enzymatic techniques of staining, plus the biochemical modifications of acetylcholinesterase (AChE) activity. Specimens obtained from human mesenteric lymphatic vessels were subjected to the following experimental procedures: 1) drawing, cutting and staining of tissues; 2) staining of total nerve fibres; 3) enzymatic staining of cholinergic nerve fibres; 4) homogenisation of tissues; 5) biochemical amount of proteins; 6) biochemical amount of AChE activity; 6) quantitative analysis of images; 7) statistical analysis of data. The mesenteric lymphatic vessels show many AChE positive nerve fibres around their wall with an almost plexiform distribution. The incubation time was performed at 1 h (partial activity) and 6 h (total activity). Moreover, biochemical dosage of the same enzymatic activity confirms the results obtained with morphological methods. The homogenates of the studied tissues contain strong AChE activity. In our study, the lymphatic vessels appeared to contain few cholinergic nerve fibres. Therefore, it is expected that perivascular nerve stimulation stimulates cholinergic nerves innervating the mesenteric arteries to release the neurotransmitter AChE, which activates muscarinic or nicotinic receptors to modulate adrenergic neurotransmission. These results strongly suggest, that perivascular cholinergic nerves have little or no effect on the adrenergic nerve function in mesenteric arteries. The cholinergic nerves innervating mesenteric arteries do not mediate direct vascular responses.

  9. Trends in Tissue Engineering for Blood Vessels

    Directory of Open Access Journals (Sweden)

    Judee Grace Nemeno-Guanzon

    2012-01-01

    Full Text Available Over the years, cardiovascular diseases continue to increase and affect not only human health but also the economic stability worldwide. The advancement in tissue engineering is contributing a lot in dealing with this immediate need of alleviating human health. Blood vessel diseases are considered as major cardiovascular health problems. Although blood vessel transplantation is the most convenient treatment, it has been delimited due to scarcity of donors and the patient’s conditions. However, tissue-engineered blood vessels are promising alternatives as mode of treatment for blood vessel defects. The purpose of this paper is to show the importance of the advancement on biofabrication technology for treatment of soft tissue defects particularly for vascular tissues. This will also provide an overview and update on the current status of tissue reconstruction especially from autologous stem cells, scaffolds, and scaffold-free cellular transplantable constructs. The discussion of this paper will be focused on the historical view of cardiovascular tissue engineering and stem cell biology. The representative studies featured in this paper are limited within the last decade in order to trace the trend and evolution of techniques for blood vessel tissue engineering.

  10. Hawaii Abandoned Vessel Inventory, Kauai

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Kauai. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  11. CNMI Abandoned Vessel Inventory, Tinian

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Tinian. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  12. Puerto Rico Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Puerto Rico. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  13. American Samoa Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for American Samoa. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  14. Hawaii Abandoned Vessel Inventory, Oahu

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Oahu, Hawaii. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  15. Hawaii Abandoned Vessel Inventory, Molokai

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Molokai, Hawaii. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  16. CNMI Abandoned Vessel Inventory, Rota

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Rota. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  17. Hawaii Abandoned Vessel Inventory, Lanai

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Lanai. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  18. For-Hire Vessel Directory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Vessel Directory is maintained as the sample frame for the For-Hire Survey. I contains data on for-hire vessels on the Atlantic and Gulf coasts. Data include...

  19. CNMI Abandoned Vessel Inventory, Saipan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Saipan. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  20. Hawaii Abandoned Vessel Inventory, Maui

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Maui. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  1. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  2. New research vessels

    Science.gov (United States)

    1984-04-01

    Two “new” ocean-going research vessels operated by the Scripps Institution of Oceanography and the National Science Foundation (NSF) will soon begin full-time scientific duties off the coast of California and in the Antarctic, respectively. The 37.5-m Scripps vessel, named Robert Gordon Sprout in honor of the ex-president of the University of California, replaces the smaller ship Ellen B. Scripps, which had served the institution since 1965. The new ship is a slightly modified Gulf Coast workboat. Under the name of Midnight Alaskan, it had been used for high-resolution geophysical surveys in American and Latin American waters by such firms as Arco Oil & Gas, Exxon, Pennzoil, and Racal-Decca before its purchase by Scripps from a Lousiana chartering firm last summer.

  3. Large vessel vasculitides

    OpenAIRE

    Morović-Vergles, Jadranka; Pukšić, Silva; Gudelj Gračanin, Ana

    2013-01-01

    Large vessel vasculitis includes Giant cell arteritis and Takayasu arteritis. Giant cell arteritis is the most common form of vasculitis affect patients aged 50 years or over. The diagnosis should be considered in older patients who present with new onset of headache, visual disturbance, polymyalgia rheumatica and/or fever unknown cause. Glucocorticoides remain the cornerstone of therapy. Takayasu arteritis is a chronic panarteritis of the aorta ant its major branches presenting commonly in y...

  4. Very Versatile Vessel

    Science.gov (United States)

    2009-09-01

    data. This source provides information on aluminum hydrofoil vessels without the added weight of foil structures. The composite armor around the...seating compartment. The sides should also limit wave splash on the deck. The freeboard should contribute reserve buoyancy , increasing large-angle and...Resistance, Powering, and Propulsion Savitsky’s Method Since model testing data or other reliable performance data was unavailable for the proposed

  5. Retinal vessel centerline extraction using multiscale matched filters, confidence and edge measures.

    Science.gov (United States)

    Sofka, Michal; Stewart, Charles V

    2006-12-01

    Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence measures and vessel boundary measures. Matched filter responses are derived in scale-space to extract vessels of widely varying widths. A vessel confidence measure is defined as a projection of a vector formed from a normalized pixel neighborhood onto a normalized ideal vessel profile. Vessel boundary measures and associated confidences are computed at potential vessel boundaries. Combined, these responses form a six-dimensional measurement vector at each pixel. A training technique is used to develop a mapping of this vector to a likelihood ratio that measures the "vesselness" at each pixel. Results comparing this vesselness measure to matched filters alone and to measures based on the Hessian of intensities show substantial improvements, both qualitatively and quantitatively. The Hessian can be used in place of the matched filter to obtain similar but less-substantial improvements or to steer the matched filter by preselecting kernel orientations. Finally, the new vesselness likelihood ratio is embedded into a vessel tracing framework, resulting in an efficient and effective vessel centerline extraction algorithm.

  6. Boosted learned kernels for data-driven vesselness measure

    Science.gov (United States)

    Grisan, E.

    2017-03-01

    Common vessel centerline extraction methods rely on the computation of a measure providing the likeness of the local appearance of the data to a curvilinear tube-like structure. The most popular techniques rely on empirically designed (hand crafted) measurements as the widely used Hessian vesselness, the recent oriented flux tubeness or filters (e.g. the Gaussian matched filter) that are developed to respond to local features, without exploiting any context information nor the rich structural information embedded in the data. At variance with the previously proposed methods, we propose a completely data-driven approach for learning a vesselness measure from expert-annotated dataset. For each data point (voxel or pixel), we extract the intensity values in a neighborhood region, and estimate the discriminative convolutional kernel yielding a positive response for vessel data and negative response for non-vessel data. The process is iterated within a boosting framework, providing a set of linear filters, whose combined response is the learned vesselness measure. We show the results of the general-use proposed method on the DRIVE retinal images dataset, comparing its performance against the hessian-based vesselness, oriented flux antisymmetry tubeness, and vesselness learned with a probabilistic boosting tree or with a regression tree. We demonstrate the superiority of our approach that yields a vessel detection accuracy of 0.95, with respect to 0.92 (hessian), 0.90 (oriented flux) and 0.85 (boosting tree).

  7. Vessel Traffic Services.

    Science.gov (United States)

    1982-12-01

    Yorker" articles titled Silent Spring by Rachel Carson in 1963 produced a unifying effect, "the sort of rallying point of the movement to protect the...6232, 92d Cong., 1st. sess., 1971, p. 2. 15. Carson , Rachel L. , The Sea Around Us, New York: Oxford Univesity Press, 195-, p. IV. 16. U.S., Congress...Government Printing Office, 1974. 63. Buhler, L. and Geiger, J., Vessel Traffic Data Extraction MethodoloqX, Silver Spring , Maryland, O6erFae-tns

  8. Vanishing corneal vessels

    Science.gov (United States)

    Nicholson, Luke; Chana, Rupinder

    2013-01-01

    We wish to highlight the importance of acknowledging the accompanying effects of topical phenylephrine drops on the eye other than its intended mydriasis. We reported a case of a 92-year-old woman with a corneal graft who was noted to have superficial corneal vascularisation which was not documented previously. After the instillation of topical tropicamide 1% and phenylephrine 2.5%, for funduscopy, the corneal vascularisation was not visible. When reassessed on another visit, tropicamide had no effect on the vessels and only phenylephrine did. We wish to highlight that when reviewing patients in cornea clinics, instilling phenylephrine prior to being seen may mask important corneal vascularisation. PMID:24121816

  9. 46 CFR 289.2 - Vessels included.

    Science.gov (United States)

    2010-10-01

    ... CONSTRUCTION-DIFFERENTIAL SUBSIDY VESSELS, OPERATING-DIFFERENTIAL SUBSIDY VESSELS AND OF VESSELS SOLD OR ADJUSTED UNDER THE MERCHANT SHIP SALES ACT 1946 § 289.2 Vessels included. Vessels subject to the provisions of this part are: (a) All vessels which may in the future be constructed or sold with construction...

  10. Vessel wall characterization using quantitative MRI: what's in a number?

    Science.gov (United States)

    Coolen, Bram F; Calcagno, Claudia; van Ooij, Pim; Fayad, Zahi A; Strijkers, Gustav J; Nederveen, Aart J

    2018-02-01

    The past decade has witnessed the rapid development of new MRI technology for vessel wall imaging. Today, with advances in MRI hardware and pulse sequences, quantitative MRI of the vessel wall represents a real alternative to conventional qualitative imaging, which is hindered by significant intra- and inter-observer variability. Quantitative MRI can measure several important morphological and functional characteristics of the vessel wall. This review provides a detailed introduction to novel quantitative MRI methods for measuring vessel wall dimensions, plaque composition and permeability, endothelial shear stress and wall stiffness. Together, these methods show the versatility of non-invasive quantitative MRI for probing vascular disease at several stages. These quantitative MRI biomarkers can play an important role in the context of both treatment response monitoring and risk prediction. Given the rapid developments in scan acceleration techniques and novel image reconstruction, we foresee the possibility of integrating the acquisition of multiple quantitative vessel wall parameters within a single scan session.

  11. Blood flow reprograms lymphatic vessels to blood vessels.

    Science.gov (United States)

    Chen, Chiu-Yu; Bertozzi, Cara; Zou, Zhiying; Yuan, Lijun; Lee, John S; Lu, MinMin; Stachelek, Stan J; Srinivasan, Sathish; Guo, Lili; Vicente, Andres; Vincente, Andres; Mericko, Patricia; Levy, Robert J; Makinen, Taija; Oliver, Guillermo; Kahn, Mark L

    2012-06-01

    Human vascular malformations cause disease as a result of changes in blood flow and vascular hemodynamic forces. Although the genetic mutations that underlie the formation of many human vascular malformations are known, the extent to which abnormal blood flow can subsequently influence the vascular genetic program and natural history is not. Loss of the SH2 domain-containing leukocyte protein of 76 kDa (SLP76) resulted in a vascular malformation that directed blood flow through mesenteric lymphatic vessels after birth in mice. Mesenteric vessels in the position of the congenital lymphatic in mature Slp76-null mice lacked lymphatic identity and expressed a marker of blood vessel identity. Genetic lineage tracing demonstrated that this change in vessel identity was the result of lymphatic endothelial cell reprogramming rather than replacement by blood endothelial cells. Exposure of lymphatic vessels to blood in the absence of significant flow did not alter vessel identity in vivo, but lymphatic endothelial cells exposed to similar levels of shear stress ex vivo rapidly lost expression of PROX1, a lymphatic fate-specifying transcription factor. These findings reveal that blood flow can convert lymphatic vessels to blood vessels, demonstrating that hemodynamic forces may reprogram endothelial and vessel identity in cardiovascular diseases associated with abnormal flow.

  12. Segmentation of vessels: the corkscrew algorithm

    Science.gov (United States)

    Wesarg, Stefan; Firle, Evelyn A.

    2004-05-01

    Medical imaging is nowadays much more than only providing data for diagnosis. It also links 'classical' diagnosis to modern forms of treatment such as image guided surgery. Those systems require the identification of organs, anatomical regions of the human body etc., i. e. the segmentation of structures from medical data sets. The algorithms used for these segmentation tasks strongly depend on the object to be segmented. One structure which plays an important role in surgery planning are vessels that are found everywhere in the human body. Several approaches for their extraction already exist. However, there is no general one which is suitable for all types of data or all sorts of vascular structures. This work presents a new algorithm for the segmentation of vessels. It can be classified as a skeleton-based approach working on 3D data sets, and has been designed for a reliable segmentation of coronary arteries. The algorithm is a semi-automatic extraction technique requiring the definition of the start and end the point of the (centerline) path to be found. A first estimation of the vessel's centerline is calculated and then corrected iteratively by detecting the vessel's border perpendicular to the centerline. We used contrast enhanced CT data sets of the thorax for testing our approach. Coronary arteries have been extracted from the data sets using the 'corkscrew algorithm' presented in this work. The segmentation turned out to be robust even if moderate breathing artifacts were present in the data sets.

  13. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  14. [Large vessel vasculitides].

    Science.gov (United States)

    Morović-Vergles, Jadranka; Puksić, Silva; Gracanin, Ana Gudelj

    2013-01-01

    Large vessel vasculitis includes Giant cell arteritis and Takayasu arteritis. Giant cell arteritis is the most common form of vasculitis affect patients aged 50 years or over. The diagnosis should be considered in older patients who present with new onset of headache, visual disturbance, polymyalgia rheumatica and/or fever unknown cause. Glucocorticoides remain the cornerstone of therapy. Takayasu arteritis is a chronic panarteritis of the aorta ant its major branches presenting commonly in young ages. Although all large arteries can be affected, the aorta, subclavian and carotid arteries are most commonly involved. The most common symptoms included upper extremity claudication, hypertension, pain over the carotid arteries (carotidynia), dizziness and visual disturbances. Early diagnosis and treatment has improved the outcome in patients with TA.

  15. Vessel segmentation in screening mammograms

    Science.gov (United States)

    Mordang, J. J.; Karssemeijer, N.

    2015-03-01

    Blood vessels are a major cause of false positives in computer aided detection systems for the detection of breast cancer. Therefore, the purpose of this study is to construct a framework for the segmentation of blood vessels in screening mammograms. The proposed framework is based on supervised learning using a cascade classifier. This cascade classifier consists of several stages where in each stage a GentleBoost classifier is trained on Haar-like features. A total of 30 cases were included in this study. In each image, vessel pixels were annotated by selecting pixels on the centerline of the vessel, control samples were taken by annotating a region without any visible vascular structures. This resulted in a total of 31,000 pixels marked as vascular and over 4 million control pixels. After training, the classifier assigns a vesselness likelihood to the pixels. The proposed framework was compared to three other vessel enhancing methods, i) a vesselness filter, ii) a gaussian derivative filter, and iii) a tubeness filter. The methods were compared in terms of area under the receiver operating characteristics curves, the Az values. The Az value of the cascade approach is 0:85. This is superior to the vesselness, Gaussian, and tubeness methods, with Az values of 0:77, 0:81, and 0:78, respectively. From these results, it can be concluded that our proposed framework is a promising method for the detection of vessels in screening mammograms.

  16. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  17. Flattening maps for the visualization of multibranched vessels.

    Science.gov (United States)

    Zhu, Lei; Haker, Steven; Tannenbaum, Allen

    2005-02-01

    In this paper, we present two novel algorithms which produce flattened visualizations of branched physiological surfaces, such as vessels. The first approach is a conformal mapping algorithm based on the minimization of two Dirichlet functionals. From a triangulated representation of vessel surfaces, we show how the algorithm can be implemented using a finite element technique. The second method is an algorithm which adjusts the conformal mapping to produce a flattened representation of the original surface while preserving areas. This approach employs the theory of optimal mass transport. Furthermore, a new way of extracting center lines for vessel fly-throughs is provided.

  18. Microsurgical Training using Reusable Human Vessels from Discarded Tissues in Lymph Node Dissection

    Directory of Open Access Journals (Sweden)

    Naohiro Ishii

    2016-11-01

    Full Text Available The use of human vessels at the beginning of microsurgery training is highly recommended. But vessels with the appropriate length for training are not often obtained. Whether these vessels may be reused for training has not been reported. Accordingly, we harvested vessels from discarded tissues in lymph node dissection and demonstrated that vascular anastomosis training using the same human vessels several times is possible by placing the vessels in a freezer and defrosting them with hot water. Vascular walls can be stored for microsurgical training until about 4 years after harvest, as shown in the gross appearance and histologic findings of our preserved vessels. We recommend the technique presented here for the longterm reuse of human vessels for microsurgery training that closely resembles real procedures.

  19. 50 CFR 648.8 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 8 2010-10-01 2010-10-01 false Vessel identification. 648.8 Section 648.8... identification. (a) Vessel name and official number. Each fishing vessel subject to this part and over 25 ft (7.6... or ocean quahog vessels licensed under New Jersey law may use the appropriate vessel identification...

  20. Primo-vessels and primo-nodes in rat brain, spine and sciatic nerve.

    Science.gov (United States)

    Lee, Byung-Cheon; Eom, Ki-Hoon; Soh, Kwang-Sup

    2010-06-01

    We report a method using Trypan blue staining to detect primo-vessels in the nervous system on internal organs or in the skin of rat. We applied this technique to visualize the primo-vessels and primo-nodes in the brain, spinal cord and sciatic nerve of a rat. Primo-vessels and primo-nodes were preferentially stained at nerves, blood vessels, or fascia-like membranes and turned blue after the spread and washing of Trypan blue. The physiological role of the primo-vessels within the nervous system is an important question warranting further investigation. Copyright 2010 Korean Pharmacopuncture Institute. Published by .. All rights reserved.

  1. 2D Fast Vessel Visualization Using a Vessel Wall Mask Guiding Fine Vessel Detection

    Directory of Open Access Journals (Sweden)

    Sotirios Raptis

    2010-01-01

    and then try to approach the ridges and branches of the vasculature's using fine detection. Fine vessel screening looks into local structural inconsistencies in vessels properties, into noise, or into not expected intensity variations observed inside pre-known vessel-body areas. The vessels are first modelled sufficiently but not precisely by their walls with a tubular model-structure that is the result of an initial segmentation. This provides a chart of likely Vessel Wall Pixels (VWPs yielding a form of a likelihood vessel map mainly based on gradient filter's intensity and spatial arrangement parameters (e.g., linear consistency. Specific vessel parameters (centerline, width, location, fall-away rate, main orientation are post-computed by convolving the image with a set of pre-tuned spatial filters called Matched Filters (MFs. These are easily computed as Gaussian-like 2D forms that use a limited range sub-optimal parameters adjusted to the dominant vessel characteristics obtained by Spatial Grey Level Difference statistics limiting the range of search into vessel widths of 16, 32, and 64 pixels. Sparse pixels are effectively eliminated by applying a limited range Hough Transform (HT or region growing. Major benefits are limiting the range of parameters, reducing the search-space for post-convolution to only masked regions, representing almost 2% of the 2D volume, good speed versus accuracy/time trade-off. Results show the potentials of our approach in terms of time for detection ROC analysis and accuracy of vessel pixel (VP detection.

  2. Histological evaluation and optimization of surgical vessel sealing systems

    Science.gov (United States)

    Lathrop, Robert; Ryan, Thomas; Gaspredes, Jonathan; Woloszko, Jean; Coad, James E.

    2017-02-01

    Surgical vessel sealing systems are widely used to achieve hemostasis and dissection in open surgery and minimally invasive, laparoscopic surgery. This enabling technology was developed about 17 years ago and continues to evolve with new devices and systems achieving improved outcomes. Histopathological assessment of thermally sealed tissues is a valuable tool for refining and comparing performance among surgical vessel sealing systems. Early work in this field typically assessed seal time, burst rate, and failure rate (in-situ). Later work compared histological staining methods with birefringence to assess the extent of thermal damage to tissues adjacent to the device. Understanding the microscopic architecture of a sealed vessel is crucial to optimizing the performance of power delivery algorithms and device design parameters. Manufacturers rely on these techniques to develop new products. A system for histopathological evaluation of vessels and sealing performance was established, to enable the direct assessment of a treatment's tissue effects. The parameters included the commonly used seal time, pressure burst rate and failure rate, as well as extensions of the assessment to include its likelihood to form steam vacuoles, adjacent thermal effect near the device, and extent of thermally affected tissue extruded back into the vessel lumen. This comprehensive assessment method provides an improved means of assessing the quality of a sealed vessel and understanding the exact mechanisms which create an optimally sealed vessel.

  3. BY FRUSTUM CONFINING VESSEL

    Directory of Open Access Journals (Sweden)

    Javad Khazaei

    2016-09-01

    Full Text Available Helical piles are environmentally friendly and economical deep foundations that, due to environmental considerations, are excellent additions to a variety of deep foundation alternatives available to the practitioner. Helical piles performance depends on soil properties, the pile geometry and soil-pile interaction. Helical piles can be a proper alternative in sensitive environmental sites if their bearing capacity is sufficient to support applied loads. The failure capacity of helical piles in this study was measured via an experimental research program that was carried out by Frustum Confining Vessel (FCV. FCV is a frustum chamber by approximately linear increase in vertical and lateral stresses along depth from top to bottom. Due to special geometry and applied bottom pressure, this apparatus is a proper choice to test small model piles which can simulate field stress conditions. Small scale helical piles are made with either single helix or more helixes and installed in fine grained sand with three various densities. Axial loading tests including compression and tension tests were performed to achieve pile ultimate capacity. The results indicate the helical piles behavior depends essentially on pile geometric characteristics, i.e. helix configuration and soil properties. According to the achievements, axial uplift capacity of helical model piles is about equal to usual steel model piles that have the helixes diameter. Helical pile compression bearing capacity is too sufficient to act as a medium pile, thus it can be substituted other piles in special geoenvironmental conditions. The bearing capacity also depends on spacing ratio, S/D, and helixes diameter.

  4. Southeast Region Headboat Survey-Vessel list/Vessel Directory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is a database of vessels that have been on the SRHS through time, their owners/operators, marinas/docks and their contact information. This assists in...

  5. Comparison of approaches for microscopic imaging of skin lymphatic vessels.

    Science.gov (United States)

    Wu, Xiufeng; Yu, Zheyuan; Liu, Ningfei

    2012-01-01

    Assessment of skin lymphatic vessels is of great significance in understanding their roles in many pathological conditions. Our aim was to identify the optimal approach for investigation of cutaneous lymphatic system. We performed comparative studies on skin lymphatic vessels using immunohistochemistry of tissue sections, computer graphic reconstruction method together with immunohistochemically stained serial sections and whole mount fluorescence in human lower limb. Lymphatic vessels were identified with podoplanin antibody. The relative merits and drawbacks of each method in evaluation of structure, spatial organization, and distribution of cutaneous lymphatic vessels were described. Immunohistology of tissue sections enabled the investigation of the structure and distribution of the whole cutaneous lymphatic system in two-dimensional slices, whereas three-dimensional morphology of only the most superficial lymph capillary network immediately under the epidermis could be evaluated with the whole mount technique. Meanwhile, only little segmentation of skin lymphatic vessel from five immunohistochemically stained serial sections was reconstructed and evaluated due to expense and special skills required using computer graphic three-dimensional reconstruction. Furthermore, a great number of artifacts and special skills required in its processes leaded to less accurate structure of skin lymphatic vessels. Our findings demonstrated that the use of either of the proposed techniques alone could not allow a comprehensive analysis of the skin lymphatic system due to their relative drawbacks. Combination of immunohistology of tissue sections and three-dimensional whole-mount preparations appears to be the best candidate for comprehensive evaluation of skin lymphatic system. © Wiley Periodicals, Inc.

  6. Efficient Vessel Tracking  with Accuracy Guarantees

    DEFF Research Database (Denmark)

    Redoutey, Martin; Scotti, Eric; Jensen, Christian Søndergaard

    2008-01-01

    Safety and security are top concerns in maritime navigation, particularly as maritime traffic continues to grow and as crew sizes are reduced. The Automatic Identification System (AIS) plays a key role in regard to these concerns. This system, whose objective is in part to identify and locate ves...... accuracies at lower communication costs. The techniques employ movement predictions that are shared between vessels and the VTS. Empirical studies with a prototype implementation and real vessel data demonstrate that the techniques are capable of significantly improving the AIS....

  7. 2013 East Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  8. SC/OQ Vessel Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data tables holding information for the Surf Clam/Ocean Quahog vessel and dealer/processor logbooks (negative and positive), as well as individual tag information...

  9. 2011 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  10. 2011 West Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  11. 2013 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  12. 2011 East Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  13. Integrin binding: Sticking around vessels

    Science.gov (United States)

    Blatchley, Michael R.; Gerecht, Sharon

    2017-09-01

    A study demonstrates that controlled integrin binding on a biomaterial was capable of promoting vascular cell sprouting and formation of a non-leaky blood vessel network in a healthy and diseased state.

  14. Transposition of the great vessels

    Science.gov (United States)

    ... vessel called the ductus arteriosus open, allowing some mixing of the 2 blood circulations. A procedure using ... they are not already immune. Eating well, avoiding alcohol, and controlling diabetes both before and during pregnancy ...

  15. 2013 West Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  16. Vessel Permit System Data Set

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — GARFO issues federal fishing permits annually to owners of fishing vessels who fish in the Greater Atlantic region, as required by federal regulation. These permits...

  17. 2011 Tug Towing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  18. Caribbean PR Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels fishing in Puerto Rico. The catch and effort data for the entire trip are...

  19. Coastal Discard Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data on the type and amount of marine resources that are discarded or interacted with by vessels that are selected to report to the Southeast...

  20. Prosopomorphic vessels from Moesia Superior

    Directory of Open Access Journals (Sweden)

    Nikolić Snežana

    2008-01-01

    Full Text Available The prosopomorphic vessels from Moesia Superior had the form of beakers varying in outline but similar in size. They were wheel-thrown, mould-made or manufactured by using a combination of wheel-throwing and mould-made appliqués. Given that face vessels are considerably scarcer than other kinds of pottery, more than fifty finds from Moesia Superior make an enviable collection. In this and other provinces face vessels have been recovered from military camps, civilian settlements and necropolises, which suggests that they served more than one purpose. It is generally accepted that the faces-masks gave a protective role to the vessels, be it to protect the deceased or the family, their house and possessions. More than forty of all known finds from Moesia Superior come from Viminacium, a half of that number from necropolises. Although tangible evidence is lacking, there must have been several local workshops producing face vessels. The number and technological characteristics of the discovered vessels suggest that one of the workshops is likely to have been at Viminacium, an important pottery-making centre in the second and third centuries.

  1. Robust shape regression for supervised vessel segmentation and its application to coronary segmentation in CTA

    DEFF Research Database (Denmark)

    Schaap, Michiel; van Walsum, Theo; Neefjes, Lisan

    2011-01-01

    This paper presents a vessel segmentation method which learns the geometry and appearance of vessels in medical images from annotated data and uses this knowledge to segment vessels in unseen images. Vessels are segmented in a coarse-to-fine fashion. First, the vessel boundaries are estimated...... with multivariate linear regression using image intensities sampled in a region of interest around an initialization curve. Subsequently, the position of the vessel boundary is refined with a robust nonlinear regression technique using intensity profiles sampled across the boundary of the rough segmentation...... and using information about plausible cross-sectional vessel shapes. The method was evaluated by quantitatively comparing segmentation results to manual annotations of 229 coronary arteries. On average the difference between the automatically obtained segmentations and manual contours was smaller than...

  2. Automated method for identification and artery-venous classification of vessel trees in retinal vessel networks.

    Directory of Open Access Journals (Sweden)

    Vinayak S Joshi

    Full Text Available The separation of the retinal vessel network into distinct arterial and venous vessel trees is of high interest. We propose an automated method for identification and separation of retinal vessel trees in a retinal color image by converting a vessel segmentation image into a vessel segment map and identifying the individual vessel trees by graph search. Orientation, width, and intensity of each vessel segment are utilized to find the optimal graph of vessel segments. The separated vessel trees are labeled as primary vessel or branches. We utilize the separated vessel trees for arterial-venous (AV classification, based on the color properties of the vessels in each tree graph. We applied our approach to a dataset of 50 fundus images from 50 subjects. The proposed method resulted in an accuracy of 91.44% correctly classified vessel pixels as either artery or vein. The accuracy of correctly classified major vessel segments was 96.42%.

  3. 50 CFR 697.8 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel identification. 697.8 Section 697.8 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION....8 Vessel identification. (a) Vessel name and official number. Each fishing vessel issued a limited...

  4. Mechanosensing in developing lymphatic vessels.

    Science.gov (United States)

    Planas-Paz, Lara; Lammert, Eckhard

    2014-01-01

    The lymphatic vasculature is responsible for fluid homeostasis, transport of immune cells, inflammatory molecules, and dietary lipids. It is composed of a network of lymphatic capillaries that drain into collecting lymphatic vessels and ultimately bring fluid back to the blood circulation. Lymphatic endothelial cells (LECs) that line lymphatic capillaries present loose overlapping intercellular junctions and anchoring filaments that support fluid drainage. When interstitial fluid accumulates within tissues, the extracellular matrix (ECM) swells and pulls the anchoring filaments. This results in opening of the LEC junctions and permits interstitial fluid uptake. The absorbed fluid is then transported within collecting lymphatic vessels, which exhibit intraluminal valves that prevent lymph backflow and smooth muscle cells that sequentially contract to propel lymph.Mechanotransduction involves translation of mechanical stimuli into biological responses. LECs have been shown to sense and respond to changes in ECM stiffness, fluid pressure-induced cell stretch, and fluid flow-induced shear stress. How these signals influence LEC function and lymphatic vessel growth can be investigated by using different mechanotransduction assays in vitro and to some extent in vivo.In this chapter, we will focus on the mechanical forces that regulate lymphatic vessel expansion during embryonic development and possibly secondary lymphedema. In mouse embryos, it has been recently shown that the amount of interstitial fluid determines the extent of lymphatic vessel expansion via a mechanosensory complex formed by β1 integrin and vascular endothelial growth factor receptor-3 (VEGFR3). This model might as well apply to secondary lymphedema.

  5. Fourier cross-sectional profile for vessel detection on retinal images.

    Science.gov (United States)

    Zhu, Tao

    2010-04-01

    Retinal blood vessels are important objects in ophthalmologic images. In spite of many attempts for vessel detection, it appears that existing methodologies are based on edge detection or modeling of vessel cross-sectional profiles in intensity. The application of these methodologies is hampered by the presence of a wide range of retinal vessels. In this paper we define a universal representation for upward and downward vessel cross-sectional profiles with varying boundary sharpness. This expression is used to define a new scheme of vessel detection based on symmetry and asymmetry in the Fourier domain. Phase congruency is utilized for measuring symmetry and asymmetry so that our scheme is invariant to vessel brightness variations. We have performed experiments on fluorescein images and color fundus images to show the efficiency of the proposed algorithm technique. We also have performed a width measurement study, using an optimal medial axis skeletonization scheme as a post-processing step, to compare the technique with the generalized Gaussian profile modeling. The new algorithm technique is promising for automated vessel detection where optimizing profile models is difficult and preserving vessel width information is necessary. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  6. Magnetic resonance imaging of vessel wall morphology and function

    NARCIS (Netherlands)

    Kröner, Eleanore Sophie Jeanine

    2015-01-01

    This thesis evaluates morphological and functional vessel wall properties measured by magnetic resonance imaging techniques in healthy volunteers and patients with various diseases (i.e. Marfan syndrome patients (MFS), patients with thoracic aortic aneurysm and patients with a previous myocardial

  7. Grounding Damage to Conventional Vessels

    DEFF Research Database (Denmark)

    Lützen, Marie; Simonsen, Bo Cerup

    2003-01-01

    regulations for design of bottom compartment layout with regard to grounding damages are largely based on statistical damage data. New and updated damage statistics holding 930 grounding accident records has been investigated. The bottom damage statistics is compared to current regulations for the bottom......The present paper is concerned with rational design of conventional vessels with regard to bottom damage generated in grounding accidents. The aim of the work described here is to improve the design basis, primarily through analysis of new statistical data for grounding damage. The current...... for the relation between the amount of deformed structure and the energy absorption. Finally, the paper shows how damage statistics for existing, conventional vessels can be used together with theoretical prediction methods for determining grounding damage distributions for new vessel types not included...

  8. 19 CFR 4.5 - Government vessels.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Government vessels. 4.5 Section 4.5 Customs Duties... VESSELS IN FOREIGN AND DOMESTIC TRADES Arrival and Entry of Vessels § 4.5 Government vessels. (a) No... that is the property of, the U.S. Department of Defense (DoD) will be treated as a Government vessel...

  9. [Pulmonary blood vessels in goats].

    Science.gov (United States)

    Roos, H; Hegner, K; Vollmerhaus, B

    1999-05-01

    The blood vessels in the lung of the goat, which until now have received little attention, are described in detail for the first time. With regard to the segments of the lung, blood vessels are bronchovascular units in the lobi craniales, lobus medius and lobus accessorius, but bronchoartery units in the lobi caudales. We investigated the types of branches of the Aa. pulmonales dextra et sinistra, the inter- and intraspecific principles of the outlet of the pulmonary veins and the importance of bronchopulmonary segmentation of the lungs.

  10. Timing-Invariant Imaging of Collateral Vessels in Acute Ischemic Stroke

    NARCIS (Netherlands)

    Smit, E.J.; Vonken, E.J.; Seeters, T. van; Dankbaar, J.W.; Schaaf, I.C. van der; Kappelle, L.J.; Ginneken, B. van; Velthuis, B.K.; Prokop, M.

    2013-01-01

    BACKGROUND AND PURPOSE: Although collateral vessels have been shown to be an important prognostic factor in acute ischemic stroke, patients with lack of collaterals on standard imaging techniques may still have good clinical outcome. We postulate that in these cases collateral vessels are present

  11. Commercial Passenger Fishing Vessel Fishery

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains the logbook data from U.S.A. Commercial Passenger Fishing Vessels (CPFV) fishing in the U.S.A. EEZ and in waters off of Baja California, from...

  12. Pressure vessel and method therefor

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, Timothy

    2017-09-05

    A pressure vessel includes a pump having a passage that extends between an inlet and an outlet. A duct at the pump outlet includes at least one dimension that is adjustable to facilitate forming a dynamic seal that limits backflow of gas through the passage.

  13. BPC 157 and blood vessels.

    Science.gov (United States)

    Seiwerth, Sven; Brcic, Luka; Vuletic, Lovorka Batelja; Kolenc, Danijela; Aralica, Gorana; Misic, Marija; Zenko, Anita; Drmic, Domagoj; Rucman, Rudolf; Sikiric, Predrag

    2014-01-01

    This review focuses on the described effects of BPC 157 on blood vessels after different types of damage, and elucidate by investigating different aspects of vascular response to injury (endothelium damage, clotting, thrombosis, vasoconstriction, vasodilatation, vasculoneogenesis and edema formation) especially in connection to the healing processes. In this respect, BPC 157 was concluded to be the most potent angiomodulatory agent, acting through different vasoactive pathways and systems (e.g. NO, VEGF, FAK) and leading to optimization of the vascular response followed, as it has to be expected, by optimization of the healing process. Formation of new blood vessels involves two main, partly overlapping mechanisms, angiogenesis and vasculogenesis. The additional mechanism of arteriogenesis is involved in the formation of collaterals. In conjunction with blood vessel function, we at least have to consider leakage of fluid/proteins/plasma, resulting in edema/exudate formation as well as thrombogenesis. Blood vessels are also strongly involved in tumor biology. In this aspect, we have neoangiogenesis resulting in pathological vascularization, vascular invasion resulting in release of metastatic cells and the phenomenon of homing resulting in formation of secondary tumors--metastases.

  14. The determinants of fishing vessel accident severity.

    Science.gov (United States)

    Jin, Di

    2014-05-01

    The study examines the determinants of fishing vessel accident severity in the Northeastern United States using vessel accident data from the U.S. Coast Guard for 2001-2008. Vessel damage and crew injury severity equations were estimated separately utilizing the ordered probit model. The results suggest that fishing vessel accident severity is significantly affected by several types of accidents. Vessel damage severity is positively associated with loss of stability, sinking, daytime wind speed, vessel age, and distance to shore. Vessel damage severity is negatively associated with vessel size and daytime sea level pressure. Crew injury severity is also positively related to the loss of vessel stability and sinking. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Reactor vessel lower head integrity

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, A.M.

    1997-02-01

    On March 28, 1979, the Three Mile Island Unit 2 (TMI-2) nuclear power plant underwent a prolonged small break loss-of-coolant accident that resulted in severe damage to the reactor core. Post-accident examinations of the TMI-2 reactor core and lower plenum found that approximately 19,000 kg (19 metric tons) of molten material had relocated onto the lower head of the reactor vessel. Results of the OECD TMI-2 Vessel Investigation Project concluded that a localized hot spot of approximately 1 meter diameter had existed on the lower head. The maximum temperature on the inner surface of the reactor pressure vessel (RPV) in this region reached 1100{degrees}C and remained at that temperature for approximately 30 minutes before cooling occurred. Even under the combined loads of high temperature and high primary system pressure, the TMI-2 RPV did not fail. (i.e. The pressure varied from about 8.5 to 15 MPa during the four-hour period following the relocation of melt to the lower plenum.) Analyses of RPV failure under these conditions, using state-of-the-art computer codes, predicted that the RPV should have failed via local or global creep rupture. However, the vessel did not fail; and it has been hypothesized that rapid cooling of the debris and the vessel wall by water that was present in the lower plenum played an important role in maintaining RPV integrity during the accident. Although the exact mechanism(s) of how such cooling occurs is not known, it has been speculated that cooling in a small gap between the RPV wall and the crust, and/or in cracks within the debris itself, could result in sufficient cooling to maintain RPV integrity. Experimental data are needed to provide the basis to better understand these phenomena and improve models of RPV failure in severe accident codes.

  16. Evolutionary algorithm for automatic detection of blood vessel shapes

    Science.gov (United States)

    Kutics, Andrea

    1996-04-01

    Automatic detection of blood vessel shapes locating in the skin has a great diagnostic importance. In this work, an evolutionary approach operating on morphological operator and operation structures is proposed for the determination of the shape and network of blood vessels located in upper skin layers. A population of individuals comprising morphological structures is generated. A two-dimensional queue like data representation of individuals is applied in order to provide an appropriate representation of the connectivity constraints originated in the two dimensional nature of the structuring elements. Two-dimensional crossover and mutation type manipulation operations are carried out on selected elements of the population. Unlike the usual techniques, in our approach no constraints are used for background and smoothness as no matched filter or linear operator is applied. Also no a priori knowledge of the vessel shape is necessary due to the evolutionary method. Unlike the usual imaging techniques, that mainly use angiograms as input, in this work infrared filtered images taken by CCD camera are applied to investigate the blood vessels of broad skin areas. The method is implemented parallel on a lattice network of transputers resulting in a significantly decreased processing time compared to the usual techniques.

  17. 46 CFR 42.05-63 - Ship(s) and vessel(s).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Ship(s) and vessel(s). 42.05-63 Section 42.05-63... BY SEA Definition of Terms Used in This Subchapter § 42.05-63 Ship(s) and vessel(s). The terms ship(s) and vessel(s) are interchangeable or synonymous words, and include every description of watercraft...

  18. Vessel tree extraction using locally optimal paths

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau; van Ginneken, Bram; de Bruijne, Marleen

    2010-01-01

    This paper proposes a method to extract vessel trees by continually extending detected branches with locally optimal paths. Our approach uses a cost function from a multi scale vessel enhancement filter. Optimal paths are selected based on rules that take into account the geometric characteristics...... of the vessel tree. Experiments were performed on 10 low dose chest CT scans for which the pulmonary vessel trees were extracted. The proposed method is shown to extract a better connected vessel tree and extract more of the small peripheral vessels in comparison to applying a threshold on the output...

  19. Electrically conductive containment vessel for molten aluminum

    Science.gov (United States)

    Holcombe, C.E.; Scott, D.G.

    1984-06-25

    The present invention is directed to a containment vessel which is particularly useful in melting aluminum. The vessel of the present invention is a multilayered vessel characterized by being electrically conductive, essentially nonwettable by and nonreactive with molten aluminum. The vessel is formed by coating a tantalum substrate of a suitable configuration with a mixture of yttria and particulate metal 10 borides. The yttria in the coating inhibits the wetting of the coating while the boride particulate material provides the electrical conductivity through the vessel. The vessel of the present invention is particularly suitable for use in melting aluminum by ion bombardment.

  20. Detecting Vessels Carrying Migrants Using Machine Learning

    Science.gov (United States)

    Sfyridis, A.; Cheng, T.; Vespe, M.

    2017-10-01

    Political instability, conflicts and inequalities result into significant flows of people worldwide, moving to different countries in search of a better life, safety or to be reunited with their families. Irregular crossings into Europe via sea routes, despite not being new, have recently increased together with the loss of lives of people in the attempt to reach EU shores. This highlights the need to find ways to improve the understanding of what is happening at sea. This paper, intends to expand the knowledge available on practices among smugglers and contribute to early warning and maritime situational awareness. By identifying smuggling techniques and based on anomaly detection methods, behaviours of interest are modelled and one class support vector machines are used to classify unlabelled data and detect potential smuggling vessels. Nine vessels are identified as potentially carrying irregular migrants and refugees. Though, further inspection of the results highlights possible misclassifications caused by data gaps and limited knowledge on smuggling tactics. Accepted classifications are considered subject to further investigation by the authorities.

  1. DETECTING VESSELS CARRYING MIGRANTS USING MACHINE LEARNING

    Directory of Open Access Journals (Sweden)

    A. Sfyridis

    2017-10-01

    Full Text Available Political instability, conflicts and inequalities result into significant flows of people worldwide, moving to different countries in search of a better life, safety or to be reunited with their families. Irregular crossings into Europe via sea routes, despite not being new, have recently increased together with the loss of lives of people in the attempt to reach EU shores. This highlights the need to find ways to improve the understanding of what is happening at sea. This paper, intends to expand the knowledge available on practices among smugglers and contribute to early warning and maritime situational awareness. By identifying smuggling techniques and based on anomaly detection methods, behaviours of interest are modelled and one class support vector machines are used to classify unlabelled data and detect potential smuggling vessels. Nine vessels are identified as potentially carrying irregular migrants and refugees. Though, further inspection of the results highlights possible misclassifications caused by data gaps and limited knowledge on smuggling tactics. Accepted classifications are considered subject to further investigation by the authorities.

  2. Gamma radiography of refractory-lined vessels and components

    Energy Technology Data Exchange (ETDEWEB)

    Lapinski, N. P.

    1978-08-01

    Materials used in coal-conversion systems are exposed to high pressure, high temperature, corrosive and erosive gases, and liquids containing particulate matter. These severe environments necessitate an assessment of the integrity of components to prevent premature failures. Gamma radiography was evaluated as a viable technique for testing such components in the laboratory or after operation in situ. Penetrameters (image-quality indicators) were developed for refractory-lined vessels and transfer lines, and exposure times for various combinations of refractory-steel thicknesses were determined. Radiography with /sup 60/Co was performed on gasifier vessels, combustor vessels, and critical transfer lines in existing pilot plants using the experience gained through laboratory experiments. The results show that gamma radiography is a practical and effective method to detect critical conditions in coal-conversion system components. 18 figures, 3 tables.

  3. Customizable engineered blood vessels using 3D printed inserts.

    Science.gov (United States)

    Pinnock, Cameron B; Meier, Elizabeth M; Joshi, Neeraj N; Wu, Bin; Lam, Mai T

    2016-04-15

    Current techniques for tissue engineering blood vessels are not customizable for vascular size variation and vessel wall thickness. These critical parameters vary widely between the different arteries in the human body, and the ability to engineer vessels of varying sizes could increase capabilities for disease modeling and treatment options. We present an innovative method for producing customizable, tissue engineered, self-organizing vascular constructs by replicating a major structural component of blood vessels - the smooth muscle layer, or tunica media. We utilize a unique system combining 3D printed plate inserts to control construct size and shape, and cell sheets supported by a temporary fibrin hydrogel to encourage cellular self-organization into a tubular form resembling a natural artery. To form the vascular construct, 3D printed inserts are adhered to tissue culture plates, fibrin hydrogel is deposited around the inserts, and human aortic smooth muscle cells are then seeded atop the fibrin hydrogel. The gel, aided by the innate contractile properties of the smooth muscle cells, aggregates towards the center post insert, creating a tissue ring of smooth muscle cells. These rings are then stacked into the final tubular construct. Our methodology is robust, easily repeatable and allows for customization of cellular composition, vessel wall thickness, and length of the vessel construct merely by varying the size of the 3D printed inserts. This platform has potential for facilitating more accurate modeling of vascular pathology, serving as a drug discovery tool, or for vessel repair in disease treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. [Study on distribution and drainage of lymphatic vessels of tongue].

    Science.gov (United States)

    Han, Xin-guang; Li, Jin-rong; Pi, Xin

    2005-10-01

    To investigate the distribution and drainage of lymphatic vessels of tongue, and to provide anatomical evidence for treatment of tongue cancer. Indirect lymphatic injection was employed, combined with clearing method with winter green oil and corrosive cast technique, to study the distribution of lymphatic vessels of tongue. Anatomical methods were used to detect the sentinel lymph nodes in different region of tongue. The lymphatic vessels of dorsal mucosa composed of lymphocapillary vessels and anstomosing side branches were present by superficial and deep capillary networks. The distribution of lymphatic networks extend from tip to base and from one board to another, and was not influenced by the sulcus tenninalis and median lingual sulcus. Lymphatic vessels in the muscular portion communicated with lymphocapillary network of dorsal and ventral mucosa, which made the lymphatic vessels of tongue to be an integrity network structure. These characters of distribution influenced the lymphatic drainage of tongue. The results showed principal sentinel lymph nodes (SLNs) for anterior part of tongue were submental lymph nodes, submandibular lymph nodes and juguloomohyoid lymph nodes, for lateral part and middle part of tongue were submandibular lymph nodes, jugulodigastric lymph nodes and thyroid lymph nodes, and for root part of tongue were jugulodigastric lymph nodes. SLNs for every injection region were all presented at bilatral neck, but the frequency of stained SLNs at homolateral neck was more than that at contralateral neck. The lymphatic vessels of tongue arranged like a network, which made the lymphatic drainage at various ways and made the distribution of sentinel lymph nodes to be bilateral and dispersive.

  5. Blood Vessel Normalization in the Hamster Oral Cancer Model for Experimental Cancer Therapy Studies

    Energy Technology Data Exchange (ETDEWEB)

    Ana J. Molinari; Romina F. Aromando; Maria E. Itoiz; Marcela A. Garabalino; Andrea Monti Hughes; Elisa M. Heber; Emiliano C. C. Pozzi; David W. Nigg; Veronica A. Trivillin; Amanda E. Schwint

    2012-07-01

    Normalization of tumor blood vessels improves drug and oxygen delivery to cancer cells. The aim of this study was to develop a technique to normalize blood vessels in the hamster cheek pouch model of oral cancer. Materials and Methods: Tumor-bearing hamsters were treated with thalidomide and were compared with controls. Results: Twenty eight hours after treatment with thalidomide, the blood vessels of premalignant tissue observable in vivo became narrower and less tortuous than those of controls; Evans Blue Dye extravasation in tumor was significantly reduced (indicating a reduction in aberrant tumor vascular hyperpermeability that compromises blood flow), and tumor blood vessel morphology in histological sections, labeled for Factor VIII, revealed a significant reduction in compressive forces. These findings indicated blood vessel normalization with a window of 48 h. Conclusion: The technique developed herein has rendered the hamster oral cancer model amenable to research, with the potential benefit of vascular normalization in head and neck cancer therapy.

  6. Brain blood vessel segmentation using line-shaped profiles

    Science.gov (United States)

    Babin, Danilo; Pižurica, Aleksandra; De Vylder, Jonas; Vansteenkiste, Ewout; Philips, Wilfried

    2013-11-01

    Segmentation of cerebral blood vessels is of great importance in diagnostic and clinical applications, especially for embolization of cerebral aneurysms and arteriovenous malformations (AVMs). In order to perform embolization of the AVM, the structural and geometric information of blood vessels from 3D images is of utmost importance. For this reason, the in-depth segmentation of cerebral blood vessels is usually done as a fusion of different segmentation techniques, often requiring extensive user interaction. In this paper we introduce the idea of line-shaped profiling with an application to brain blood vessel and AVM segmentation, efficient both in terms of resolving details and in terms of computation time. Our method takes into account both local proximate and wider neighbourhood of the processed pixel, which makes it efficient for segmenting large blood vessel tree structures, as well as fine structures of the AVMs. Another advantage of our method is that it requires selection of only one parameter to perform segmentation, yielding very little user interaction.

  7. AFSC/FMA/Vessel Assessment Logging

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Vessels fishing trawl gear, vessels fishing hook-and-line and pot gear that are also greater than 57.5 feet overall, and shoreside and floating processing facilities...

  8. Hawaii Abandoned Vessel Inventory, Hawaii Island

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Hawaii Island. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  9. US Virgin Islands Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for US Virgin Islands. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of...

  10. Hawaii Abandoned Vessel Inventory, Midway Island, NWHI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Midway Island, NWHI. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of...

  11. Hawaii Abandoned Vessel Inventory, Kure, NWHI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Kure, NWHI. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  12. Actemra Approved for Certain Blood Vessel Inflammation

    Science.gov (United States)

    ... 165836.html Actemra Approved for Certain Blood Vessel Inflammation Drug will treat adults with a condition called ... to treat adults with giant cell arteritis, an inflammation of the blood vessels (vasculitis). In a media ...

  13. Hawaii Abandoned Vessel Inventory, Maro Reef, NWHI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Maro Reef, NWHI. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  14. Hawaii Abandoned Vessel Inventory, Lisianski Island, NWHI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Lisianski Island, NWHI. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction...

  15. Purification of Mouse Brain Vessels.

    Science.gov (United States)

    Boulay, Anne-Cécile; Saubaméa, Bruno; Declèves, Xavier; Cohen-Salmon, Martine

    2015-11-10

    In the brain, most of the vascular system consists of a selective barrier, the blood-brain barrier (BBB) that regulates the exchange of molecules and immune cells between the brain and the blood. Moreover, the huge neuronal metabolic demand requires a moment-to-moment regulation of blood flow. Notably, abnormalities of these regulations are etiological hallmarks of most brain pathologies; including glioblastoma, stroke, edema, epilepsy, degenerative diseases (ex: Parkinson's disease, Alzheimer's disease), brain tumors, as well as inflammatory conditions such as multiple sclerosis, meningitis and sepsis-induced brain dysfunctions. Thus, understanding the signaling events modulating the cerebrovascular physiology is a major challenge. Much insight into the cellular and molecular properties of the various cell types that compose the cerebrovascular system can be gained from primary culture or cell sorting from freshly dissociated brain tissue. However, properties such as cell polarity, morphology and intercellular relationships are not maintained in such preparations. The protocol that we describe here is designed to purify brain vessel fragments, whilst maintaining structural integrity. We show that isolated vessels consist of endothelial cells sealed by tight junctions that are surrounded by a continuous basal lamina. Pericytes, smooth muscle cells as well as the perivascular astrocyte endfeet membranes remain attached to the endothelial layer. Finally, we describe how to perform immunostaining experiments on purified brain vessels.

  16. Collapsible Cryogenic Storage Vessel Project

    Science.gov (United States)

    Fleming, David C.

    2002-01-01

    Collapsible cryogenic storage vessels may be useful for future space exploration missions by providing long-term storage capability using a lightweight system that can be compactly packaged for launch. Previous development efforts have identified an 'inflatable' concept as most promising. In the inflatable tank concept, the cryogen is contained within a flexible pressure wall comprised of a flexible bladder to contain the cryogen and a fabric reinforcement layer for structural strength. A flexible, high-performance insulation jacket surrounds the vessel. The weight of the tank and the cryogen is supported by rigid support structures. This design concept is developed through physical testing of a scaled pressure wall, and through development of tests for a flexible Layered Composite Insulation (LCI) insulation jacket. A demonstration pressure wall is fabricated using Spectra fabric for reinforcement, and burst tested under noncryogenic conditions. An insulation test specimens is prepared to demonstrate the effectiveness of the insulation when subject to folding effects, and to examine the effect of compression of the insulation under compressive loading to simulate the pressure effect in a nonrigid insulation blanket under the action atmospheric pressure, such as would be seen in application on the surface of Mars. Although pressure testing did not meet the design goals, the concept shows promise for the design. The testing program provides direction for future development of the collapsible cryogenic vessel concept.

  17. 50 CFR 660.305 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel identification. 660.305 Section 660.305 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC... Fisheries § 660.305 Vessel identification. (a) Display. The operator of a vessel that is over 25 ft (7.6 m...

  18. 50 CFR 660.704 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel identification. 660.704 Section 660.704 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC... § 660.704 Vessel identification. (a) General. This section only applies to commercial fishing vessels...

  19. 50 CFR 660.504 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel identification. 660.504 Section 660.504 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC... § 660.504 Vessel identification. (a) Official number. Each fishing vessel subject to this subpart must...

  20. 50 CFR 665.16 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel identification. 665.16 Section 665... identification. (a) Applicability. Each fishing vessel subject to this part, except those identified in paragraph (e) of this section, must be marked for identification purposes, as follows: (1) A vessel that is...

  1. Integrating Multiple Autonomous Underwater Vessels, Surface Vessels and Aircraft into Oceanographic Research Vessel Operations

    Science.gov (United States)

    McGillivary, P. A.; Borges de Sousa, J.; Martins, R.; Rajan, K.

    2012-12-01

    Autonomous platforms are increasingly used as components of Integrated Ocean Observing Systems and oceanographic research cruises. Systems deployed can include gliders or propeller-driven autonomous underwater vessels (AUVs), autonomous surface vessels (ASVs), and unmanned aircraft systems (UAS). Prior field campaigns have demonstrated successful communication, sensor data fusion and visualization for studies using gliders and AUVs. However, additional requirements exist for incorporating ASVs and UASs into ship operations. For these systems to be optimally integrated into research vessel data management and operational planning systems involves addressing three key issues: real-time field data availability, platform coordination, and data archiving for later analysis. A fleet of AUVs, ASVs and UAS deployed from a research vessel is best operated as a system integrated with the ship, provided communications among them can be sustained. For this purpose, Disruptive Tolerant Networking (DTN) software protocols for operation in communication-challenged environments help ensure reliable high-bandwidth communications. Additionally, system components need to have considerable onboard autonomy, namely adaptive sampling capabilities using their own onboard sensor data stream analysis. We discuss Oceanographic Decision Support System (ODSS) software currently used for situational awareness and planning onshore, and in the near future event detection and response will be coordinated among multiple vehicles. Results from recent field studies from oceanographic research vessels using AUVs, ASVs and UAS, including the Rapid Environmental Picture (REP-12) cruise, are presented describing methods and results for use of multi-vehicle communication and deliberative control networks, adaptive sampling with single and multiple platforms, issues relating to data management and archiving, and finally challenges that remain in addressing these technological issues. Significantly, the

  2. Use of helical CT in assessment of crossing vessels in pelviureteric junction obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Lacey, N.A.; Massouh, H

    2000-03-01

    AIM: The purpose of this study is to confirm the accuracy of non-invasive helical computed tomography (CT) with multiplanar reformatting in the diagnosis of crossing vessels in patients with pelviureteric junction (PUJ) obstruction. MATERIALS AND METHODS: Nineteen patients with confirmed PUJ obstruction underwent CT of the renal area with intravenous contrast medium. Patients shown to have crossing vessels had to undergo a pyeloplasty by open surgery or laparoscopy. Patients with no vessels could have their PUJ obstruction safely treated with less invasive techniques such as balloon dilatation. RESULTS: Fourteen patients were shown to have crossing vessels. Of these, 10 had their relationship to the PUJ confirmed at a subsequent laparotomy. Of the remaining four patients, one was lost to follow-up and two were unwell due to unrelated disease. The other patient had already had a vessel moved at a previous laparotomy. Of the five patients without obstructing vessels, two were confirmed not to have a related vessel at laparotomy, one has undergone balloon dilatation and the other two were lost to follow-up. CONCLUSION: Helical CT is an accurate and non-invasive method of demonstrating crossing vessels in PUJ obstruction. Diagnosis of these vessels has a major role in the choice of therapeutic treatment. Lacey, N.A., Massouh, H. (2000)

  3. Effects of ligation of lateral intermuscular septum perforating vessels on blood supply to the femur.

    Science.gov (United States)

    Grob, K; Manestar, M; Lang, A; Ackland, T; Gilbey, H; Kuster, M S

    2015-12-01

    With a subvastus approach to the femur, the vessels that perforate the lateral intermuscular septum (LISP-vessels) must be ligated. The effect on the blood supply to the femur remains unclear. The purpose of the current study was to investigate the effect of ligation of the LISP-Vessels on the blood supply and to examine the anatomy of the LISP-vessels and the anastomoses around the femur. In six human cadavers the LISP vessels were ligated by a lateral subvastus approach on one side. The contralateral side served as control group. After bilateral injection of different coloured silicon dyes into the lateral and medial circumflex femoral artery (green), deep femoral artery (red) and the superficial femoral artery (blue) dissection was performed bilaterally. The arterial perfusion on both sides was compared and the anatomy of the LISP vessels studied. The medullary perfusion of the femur was not altered by the ligation of the LISP vessels. It did also not lead to a decrease in periosteal vessel filling. The LISP vessels were shown to be a part of a complex and rich anastomotic network and play an important role in the perfusion of the femur and quadriceps muscle group. The ligature could be compensated for by this anastomotic network. Branches to the periosteum separate from the LISP vessels immediately after perforating the lateral intermuscular septum. The linea aspera turned out to be an important area for the femoral blood supply. Exposure of the femur through a lateral subvastus approach with ligation of LISP vessels causes a certain degree of soft tissue trauma. However, by using a gentle surgical technique the periostal perfusion of the femur can be preserved by a potent anastomotic network after ligation of the LISP vessels if they are not ligated to close to the lateral intermuscular septum and the linea aspera is not unnecessarily exposed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Progress of ITER vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, K., E-mail: Kimihiro.Ioki@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Bayon, A. [F4E, c/ Josep Pla, No. 2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain); Choi, C.H.; Daly, E.; Dani, S.; Davis, J.; Giraud, B.; Gribov, Y.; Hamlyn-Harris, C.; Jun, C.; Levesy, B. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Kim, B.C. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Kuzmin, E. [NTC “Sintez”, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Le Barbier, R.; Martinez, J.-M. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Pathak, H. [ITER-India, A-29, GIDC Electronic Estate, Sector 25, Gandhinagar 382025 (India); Preble, J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Sa, J.W. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Terasawa, A.; Utin, Yu. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); and others

    2013-10-15

    Highlights: ► This covers the overall status and progress of the ITER vacuum vessel activities. ► It includes design, R and D, manufacturing and approval process of the regulators. ► The baseline design was completed and now manufacturing designs are on-going. ► R and D includes ISI, dynamic test of keys and lip-seal welding/cutting technology. ► The VV suppliers produced full-scale mock-ups and started VV manufacturing. -- Abstract: Design modifications were implemented in the vacuum vessel (VV) baseline design in 2011–2012 for finalization. The modifications are mostly due to interface components, such as support rails and feedthroughs for the in-vessel coils (IVC). Manufacturing designs are being developed at the domestic agencies (DAs) based on the baseline design. The VV support design was also finalized and tests on scale mock-ups are under preparation. Design of the in-wall shielding (IWS) has progressed, considering the assembly methods and the required tolerances. Further modifications are required to be consistent with the DAs’ manufacturing designs. Dynamic tests on the inter-modular and stub keys to support the blanket modules are being performed to measure the dynamic amplification factor (DAF). An in-service inspection (ISI) plan has been developed and R and D was launched for ISI. Conceptual design of the VV instrumentation has been developed. The VV baseline design was approved by the agreed notified body (ANB) in accordance with the French Nuclear Pressure Equipment Order procedure.

  5. Splenic vessel preservation versus splenic vessel resection in laparoscopic spleen-preserving distal pancreatectomy.

    Science.gov (United States)

    Hou, Baohua; Xiong, Dailan; Chen, Sheng; Ma, Tingting; Zhang, Chuanzhao; Zhou, Yu; Yin, Zi

    2017-11-09

    Laparoscopic spleen-preserving distal pancreatectomy for low-grade malignant pancreas tumours was recently demonstrated and can be performed with splenic vessel preservation (SVP) or splenic vessel resection (SVR). Whether one approach is superior to another is still a matter of debate. A systematic literature search (PubMed, Embase, Science Citation Index, Springer-Link and Cochrane Central Register of Controlled Trials) was performed. Pooled intra- and post-operative outcomes were evaluated. Stratified and sensitivity analyses were performed to explore heterogeneity between studies and to assess the effects of the study qualities. A total of six studies were included. There was no significant difference for SVR and SVP in terms of overall post-operative complications and the pooled odds ratio (OR) was 0.87 (95% confidence interval (CI) 0.55-1.38, I2  = 25%). Meta-analysis on the pooled outcome of intraoperative operative time and blood loss favoured SVR; the mean differences were 18.64 min (95% CI 6.91-30.37 min, I2  = 21%) and 65.67 mL (95% CI 18.88-112.45 mL, I2  = 48%), respectively. Subgroup analysis showed a decrease incidences in perigastric varices (OR = 0.07, 95% CI 0.03-0.18, I2  = 29%) and splenic infarction (OR = 0.16, 95% CI 0.08-0.32, I2  = 0%) in SVP. For selected patients who underwent laparoscopic spleen-preserving distal pancreatectomy, an increased preference for the SVP technique should be suggested considering its short-term benefits. However, in case of large tumours that distort and compress vessel course, SVR could be applied with acceptable splenic ischaemia and perigastric varices. © 2017 Royal Australasian College of Surgeons.

  6. Stress Rupture Life Reliability Measures for Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Murthy, Pappu L. N.; Thesken, John C.; Phoenix, S. Leigh; Grimes-Ledesma, Lorie

    2007-01-01

    Composite Overwrapped Pressure Vessels (COPVs) are often used for storing pressurant gases onboard spacecraft. Kevlar (DuPont), glass, carbon and other more recent fibers have all been used as overwraps. Due to the fact that overwraps are subjected to sustained loads for an extended period during a mission, stress rupture failure is a major concern. It is therefore important to ascertain the reliability of these vessels by analysis, since the testing of each flight design cannot be completed on a practical time scale. The present paper examines specifically a Weibull statistics based stress rupture model and considers the various uncertainties associated with the model parameters. The paper also examines several reliability estimate measures that would be of use for the purpose of recertification and for qualifying flight worthiness of these vessels. Specifically, deterministic values for a point estimate, mean estimate and 90/95 percent confidence estimates of the reliability are all examined for a typical flight quality vessel under constant stress. The mean and the 90/95 percent confidence estimates are computed using Monte-Carlo simulation techniques by assuming distribution statistics of model parameters based also on simulation and on the available data, especially the sample sizes represented in the data. The data for the stress rupture model are obtained from the Lawrence Livermore National Laboratories (LLNL) stress rupture testing program, carried out for the past 35 years. Deterministic as well as probabilistic sensitivities are examined.

  7. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  8. An angiogenesis platform using a cubic artificial eggshell with patterned blood vessels on chicken chorioallantoic membrane.

    Directory of Open Access Journals (Sweden)

    Wenjing Huang

    Full Text Available The chorioallantoic membrane (CAM containing tiny blood vessels is an alternative to large animals for studies involving angiogenesis and tissue engineering. However, there is no technique to design the direction of growing blood vessels on the CAM at the microscale level for tissue engineering experiments. Here, a methodology is provided to direct blood vessel formation on the surface of a three-dimensional egg yolk using a cubic artificial eggshell with six functionalized membranes. A structure on the lateral side of the eggshell containing a straight channel and an interlinked chamber was designed, and the direction and formation area of blood vessels with blood flow was artfully defined by channels with widths of 70-2000 μm, without sharply reducing embryo viability. The relationship between the size of interlinked chamber and the induction of blood vessels was investigated to establish a theory of design. Role of negative and positive pressure in the induction of CAM with blood vessels was investigated, and air pressure change in the culture chamber was measured to demonstrate the mechanism for blood vessel induction. Histological evaluation showed that components of CAM including chorionic membrane and blood vessels were induced into the channels. Based on our design theory, blood vessels were induced into arrayed channels, and channel-specific injection and screening were realized, which demonstrated proposed applications. The platform with position- and space-controlled blood vessels is therefore a powerful tool for biomedical research, which may afford exciting applications in studies involved in local stimulation of blood vessel networks and those necessary to establish a living system with blood flow from a beating heart.

  9. Exponential Stabilization of an Underactuated Surface Vessel

    Directory of Open Access Journals (Sweden)

    Kristin Y. Pettersen

    1997-07-01

    Full Text Available The paper shows that a large class of underactuated vehicles cannot be asymptotically stabilized by either continuous or discontinuous state feedback. Furthermore, stabilization of an underactuated surface vessel is considered. Controllability properties of the surface vessels is presented, and a continuous periodic time-varying feedback law is proposed. It is shown that this feedback law exponentially stabilizes the surface vessel to the origin, and this is illustrated by simulations.

  10. Regression of mature lymphatic vessels in the cornea by photodynamic therapy.

    Science.gov (United States)

    Bucher, F; Bi, Y; Gehlsen, U; Hos, D; Cursiefen, C; Bock, F

    2014-03-01

    Corneal (lymph) angiogenesis is a predominant risk-factor for immune rejection after transplantation. Techniques to regress pre-existing pathological corneal lymphatic vessels prior to transplantation are missing so far. Therefore we analysed the possibility to regress corneal lymphatic vessels by photodynamic therapy (PDT), after intrastromal verteporfin injection. Combined hemangiogenesis and lymphangiogenesis was induced in female BALB/c mice using the murine model of suture-induced inflammatory neovascularisation. Thereafter, the treatment group received an intrastromal injection of verteporfin (controls: phosphate buffered saline (PBS)) followed by PDT. Corneas were excised at different time points (1 day, 5 days and 10 days) after PDT and corneal whole mounts were stained with CD31 and LYVE-1 to quantify hemangiogenesis and lymphangiogenesis. Whereas blood vessels showed no significant reduction after PDT, lymphatic vessels could significantly be reduced with PDT after intrastromal verteporfin injection: 1 day after PDT, lymphatic vessels were reduced by 62% (p=0.20). After 5 days and 10 days, lymphatic vessels were reduced by 51% and 48% (plymphatic vessels. This may become a new 'preconditioning strategy' to reduce pre-existing corneal lymphatic vessels prior to transplantation and thereby reduce allograft rejection in high-risk patients.

  11. Cathepsin B-mediated CD18 shedding regulates leukocyte recruitment from angiogenic vessels.

    Science.gov (United States)

    Nakao, Shintaro; Zandi, Souska; Sun, Dawei; Hafezi-Moghadam, Ali

    2018-01-01

    Cathepsin B (CtsB) contributes to atherosclerosis and cancer progression by processing the extracellular matrix and promoting angiogenesis. Although CtsB was reported to promote and reduce angiogenesis, there is no mechanistic explanation that reconciles this apparent discrepancy. CtsB cleaves CD18 from the surface of immune cells, but its contribution to angiogenesis has not been studied. We developed an in vivo technique for visualization of immune cell transmigration from corneal vessels toward implanted cytokines. Wild-type (WT) leukocytes extravasated from limbal vessels, angiogenic stalks, and growing tip vessels and migrated toward the cytokines, indicating immune competence of angiogenic vessels. Compared to WT leukocytes, CtsB-/- leukocytes accumulated in a higher number in angiogenic vessels, but extravasated less toward the implanted cytokine. The accumulated CtsB-/- leukocytes in angiogenic vessels expressed more CD18. CD18-/- leukocytes extravasated later than WT leukocytes. However, once extravasated, CD18-/- leukocytes transmigrated more rapidly than their WT counterparts. These results suggest that, although CD18 facilitates efficient extravasation, outside of the vessel CD18 interaction with the extracellular matrix, it reduced transmigration velocity. Our results reveal an unexpected role for CtsB in leukocyte extravasation and transmigration, which advances our understanding of the complex contribution of CtsB to angiogenesis.-Nakao, S., Zandi, S., Sun, D., Hafezi-Moghadam, A. Cathepsin B-mediated CD18 shedding regulates leukocyte recruitment from angiogenic vessels. © FASEB.

  12. Numerical investigation of vessel heating using a copper vapor laser and a pulsed dye laser in treating vascular skin lesions

    Science.gov (United States)

    Pushkareva, A. E.; Ponomarev, I. V.; Isaev, A. A.; Klyuchareva, S. V.

    2018-02-01

    A computer simulation technique was employed to study the selective heating of a tissue vessel using emission from a pulsed copper vapor laser and a pulsed dye laser. The depth and size of vessels that could be selectively and safely removed were determined for the lasers under examination.

  13. Visualisation of blood and lymphatic vessels with increasing exposure time of the detector

    Science.gov (United States)

    Kalchenko, V. V.; Kuznetsov, Yu L.; Meglinski, I. V.

    2013-07-01

    We describe the laser speckle contrast method for simultaneous noninvasive imaging of blood and lymphatic vessels of living organisms, based on increasing detector exposure time. In contrast to standard methods of fluorescent angiography, this technique of vascular bed imaging and lymphatic and blood vessel demarcation does not employ toxic fluorescent markers. The method is particularly promising with respect to the physiology of the cardiovascular system under in vivo conditions.

  14. Vessel classification method based on vessel behavior in the port of Rotterdam

    NARCIS (Netherlands)

    Zhou, Y.; Daamen, W.; Vellinga, T.; Hoogendoorn, S.P.

    2015-01-01

    AIS (Automatic Identification System) data have proven to be a valuable source to investigate vessel behavior. The analysis of AIS data provides a possibility to recognize vessel behavior patterns in a waterway area. Furthermore, AIS data can be used to classify vessel behavior into several

  15. A computational algorithm addressing how vessel length might depend on vessel diameter

    Science.gov (United States)

    Jing Cai; Shuoxin Zhang; Melvin T. Tyree

    2010-01-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...

  16. 76 FR 59660 - Proposed Information Collection; Comment Request; Permitting, Vessel Identification, and Vessel...

    Science.gov (United States)

    2011-09-27

    ...; Permitting, Vessel Identification, and Vessel Monitoring System Requirements for the Commercial Bottomfish... compliance with federal identification requirements and carry and maintain a satellite- based vessel monitoring system (VMS). This collection of information is needed for permit issuance, to identify actual or...

  17. Image-guided optical measurement of blood oxygen saturation within capillary vessels (Conference Presentation)

    Science.gov (United States)

    Akons, Kfir; Zeidan, Adel; Yeheskely-Hayon, Daniella; Minai, Limor; Yelin, Dvir

    2016-03-01

    Values of blood oxygenation levels are useful for assessing heart and lung conditions, and are frequently monitored during routine patient care. Independent measurement of the oxygen saturation in capillary blood, which is significantly different from that of arterial blood, is important for diagnosing tissue hypoxia and for increasing the accuracy of existing techniques that measure arterial oxygen saturation. Here, we developed a simple, non-invasive technique for measuring the reflected spectra from individual capillary vessels within a human lip, allowing local measurement of the blood oxygen saturation. The optical setup includes a spatially incoherent broadband light that was focused onto a specific vessel below the lip surface. Backscattered light was imaged by a camera for identifying a target vessel and pointing the illumination beam to its cross section. Scattered light from the vessel was then collected by a single-mode fiber and analyzed by a fast spectrometer. Spectra acquired from small capillary vessels within a volunteer lip showed the characteristic oxyhemoglobin absorption bands in real time and with a high signal-to-noise ratio. Measuring capillary oxygen saturation using this technique would potentially be more accurate compared to existing pulse oximetry techniques due to its insensitivity to the patient's skin color, pulse rate, motion, and medical condition. It could be used as a standalone endoscopic technique for measuring tissue hypoxia or in conjunction with conventional pulse oximetry for a more accurate measurement of oxygen transport in the body.

  18. MDCT of renal and mesenteric vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, D. [Dept. of Radiology, Stanford Univ. Medical Center, Stanford, CA (United States)

    2003-12-01

    Computed tomography angiography (CTA) with multiple detector-row CT (MDCT) has evolved into an established technique for non-invasive imaging of renal and mesenteric vessels. With adequate selection of acquisition parameters (thin collimation) high spatial-resolution volumetric data sets for subsequent 2D and 3D reformation can be acquired. Contrast medium (CM) injection parameters need to be adjusted to the acquisition speed of the scanners. Whereas fast acquisitions allow a reduction of total CM volume in the setting of CTA, this is not the case when CTA is combined with a second-phase abdominal MDCT acquisition for parenchymal (e.g., hepatic) imaging. Renal CTA is an accurate and reliable test for visualizing vascular anatomy and renal artery stenosis, and therefore a viable alternative to MRA in the assessment of patients with renovascular hypertension and in potential living related renal donors. CTA, combined with abdominal/parenchymal MDCT is a first-line diagnostic test in patients with suspected abdominal vascular emergencies, such as acute mesenteric ischemia, and an excellent tool to assess a wide variety of vascular abnormalities of the abdominal viscera. (orig.)

  19. 15 CFR 970.205 - Vessel safety.

    Science.gov (United States)

    2010-01-01

    ... following: (1) That any foreign flag vessel whose flag state is party to the International Convention for Safety of Life at Sea, 1974 (SOLAS 74) possesses current valid SOLAS 74 certificates; (2) That any foreign flag vessel whose flag state is not party to SOLAS 74 but is party to the International Convention...

  20. Assessing Vessel Traffic Service Operator Situation Awareness

    NARCIS (Netherlands)

    Wiersma, J.W.F.

    2010-01-01

    This thesis describes my study of situation awareness assessment of Vessel Traffic Service (VTS) operators. VTS operators are the traffic controllers on the water. They are responsible for a safe and efficient handling of vessel traffic. They monitor traffic, provide information on request and

  1. Hereditary cerebral small vessel disease and stroke

    DEFF Research Database (Denmark)

    Søndergaard, Christian Baastrup; Nielsen, Jørgen Erik; Hansen, Christine Krarup

    2017-01-01

    Cerebral small vessel disease is considered hereditary in about 5% of patients and is characterized by lacunar infarcts and white matter hyperintensities on MRI. Several monogenic hereditary diseases causing cerebral small vessel disease and stroke have been identified. The purpose of this system...

  2. 33 CFR 401.67 - Explosive vessels.

    Science.gov (United States)

    2010-07-01

    ... TRANSPORTATION SEAWAY REGULATIONS AND RULES Regulations Dangerous Cargo § 401.67 Explosive vessels. A vessel carrying explosives, either Government or commercial, as defined in the Dangerous Cargo Act of the United States and in the International Maritime Dangerous Goods Code, Class 1, Divisions 1.1 to 1.5 inclusive...

  3. 78 FR 39649 - Passenger Vessels Accessibility Guidelines

    Science.gov (United States)

    2013-07-02

    ... TRANSPORTATION BARRIERS COMPLIANCE BOARD 36 CFR Part 1196 RIN 3014-AA11 Passenger Vessels Accessibility... Tuesday, June 25, 2013, make the following correction: PART 1196--PASSENGER VESSELS ACCESSIBILITY... ``Figure V703.7.2.1 International Symbol of Accessibility'' and are added to read as set forth below...

  4. Nuclear reactor vessel fuel thermal insulating barrier

    Science.gov (United States)

    Keegan, C. Patrick; Scobel, James H.; Wright, Richard F.

    2013-03-19

    The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel that has a hemispherical lower section that increases in volume from the center line of the reactor to the outer extent of the diameter of the thermal insulating barrier and smoothly transitions up the side walls of the vessel. The space between the thermal insulating harrier and the reactor vessel forms a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive inlet valve for the cooling water includes a buoyant door that is normally maintained sealed under its own weight and floats open when the cavity is Hooded. Passively opening steam vents are also provided.

  5. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV)

    Energy Technology Data Exchange (ETDEWEB)

    Qian Ming; Niu Lili; Jiang Bo; Jin Qiaofeng; Jiang Chunxiang; Zheng Hairong [Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Wang Yanping, E-mail: hr.zheng@siat.ac.c [Medical School of Jinan University, Guangzhou (China)

    2010-10-21

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  6. New techniques in CT angiography.

    Science.gov (United States)

    Lell, Michael M; Anders, Katharina; Uder, Michael; Klotz, Ernst; Ditt, Hendrik; Vega-Higuera, Fernando; Boskamp, Tobias; Bautz, Werner A; Tomandl, Bernd F

    2006-10-01

    Computed tomographic (CT) angiography has been improved significantly with the introduction of four- to 64-section spiral CT scanners, which offer rapid acquisition of isotropic data sets. A variety of techniques have been proposed for postprocessing of the resulting images. The most widely used techniques are multiplanar reformation (MPR), thin-slab maximum intensity projection, and volume rendering. Sophisticated segmentation algorithms, vessel analysis tools based on a centerline approach, and automatic lumen boundary definition are emerging techniques; bone removal with thresholding or subtraction algorithms has been introduced. These techniques increasingly provide a quality of vessel analysis comparable to that achieved with intraarterial three-dimensional rotational angiography. Neurovascular applications for these various image postprocessing methods include steno-occlusive disease, dural sinus thrombosis, vascular malformations, and cerebral aneurysms. However, one should keep in mind the potential pitfalls of these techniques and always double-check the final results with source or MPR imaging. .(c) RSNA, 2006.

  7. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D. [UCSF Benioff Children' s Hospital, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2014-07-15

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model

  8. Reactor pressure vessel. Status report

    Energy Technology Data Exchange (ETDEWEB)

    Elliot, B.J.; Hackett, E.M.; Lee, A.D. [and others

    1996-10-01

    This report describes the issues raised as a result of the staffs review of Generic Letter (GL) 92-01, Revision 1, responses and plant-specific reactor pressure vessel (RPV) assessments and the actions taken or work in progress to address these issues. In addition, the report describes actions taken by the staff and the nuclear industry to develop a thermal annealing process for use at U.S. commercial nuclear power plants. This process is intended to be used as a means of mitigating the effects of neutron radiation on the fracture toughness of RPV materials. The Nuclear Regulatory Commission (NRC) issued GL 92-01, Revision 1, Supplement 1, to obtain information needed to assess compliance with regulatory requirements and licensee commitments regarding RPV integrity. GL 92-01, Revision 1, Supplement 1, was issued as a result of generic issues that were raised in the NRC staff`s reviews of licensee responses to GL 92-01, Revision 1, and plant-specific RPV evaluations. In particular, an integrated review of all data submitted in response to GL 92-01, Revision 1, indicated that licensees may not have considered all relevant data in their RPV assessments. This report is representative of submittals to and evaluations by the staff as of September 30, 1996. An update of this report will be issued at a later date.

  9. 46 CFR 535.312 - Vessel charter party-exemption.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 9 2010-10-01 2010-10-01 false Vessel charter party-exemption. 535.312 Section 535.312... Vessel charter party-exemption. (a) For purposes of this section, vessel charter party shall mean a... operational limitations, if any) under which the vessel will be employed. (b) Vessel charter parties, as...

  10. Building foundations for transcatheter intervascular anastomoses: 3D anatomy of the great vessels in large experimental animals

    NARCIS (Netherlands)

    Sizarov, Aleksander; de Bakker, Bernadette S.; Klein, Karina; Ohlerth, Stefanie

    2014-01-01

    To provide comprehensive illustrations of anatomy of the relevant vessels in large experimental animals in an interactive format as preparation for developing an effective and safe transcatheter technique of aortopulmonary and bidirectional cavopulmonary intervascular anastomoses. Computed

  11. Technology and Organisation of Inka Pottery Production in the Leche Valley. Part II: Study of Fired Vessels

    Energy Technology Data Exchange (ETDEWEB)

    Hayashida, F. [Pennsylvania State University, Department of Anthropology (United States); Haeusler, W. [Technische Universitaet Muenchen, Physik-Department E15 (Germany); Riederer, J. [Rathgen-Forschungslabor (Germany); Wagner, U., E-mail: uwagner@ph.tum.de [Pennsylvania State University, Department of Anthropology (United States)

    2003-09-15

    Ceramic finds from the Inka workshops at Tambo Real and La Vina in the Leche Valley in northern Peru were studied by Moessbauer spectroscopy, thin section microscopy and X-ray diffraction. Sherds of Inka style vessels and of local style vessels can be distinguished by their shape, although local techniques appear to have been used in making both types. A reconstruction of the firing techniques by scientific studies of the ceramic material does not reveal a substantial difference in material or in the firing of both forms, although high firing temperatures were necessary to achieve sufficient stability of the large Inka style vessels. It cannot be decided whether the smaller local vessels were fired together with the Inka vessels or separately. Most of the variation in the maximum firing temperature can be explained with the normal temperature and atmosphere fluctuations in an open pit kiln.

  12. Technology and Organisation of Inka Pottery Production in the Leche Valley. Part II: Study of Fired Vessels

    Science.gov (United States)

    Hayashida, F.; Häusler, W.; Riederer, J.; Wagner, U.

    2003-09-01

    Ceramic finds from the Inka workshops at Tambo Real and La Viña in the Leche Valley in northern Peru were studied by Mössbauer spectroscopy, thin section microscopy and X-ray diffraction. Sherds of Inka style vessels and of local style vessels can be distinguished by their shape, although local techniques appear to have been used in making both types. A reconstruction of the firing techniques by scientific studies of the ceramic material does not reveal a substantial difference in material or in the firing of both forms, although high firing temperatures were necessary to achieve sufficient stability of the large Inka style vessels. It cannot be decided whether the smaller local vessels were fired together with the Inka vessels or separately. Most of the variation in the maximum firing temperature can be explained with the normal temperature and atmosphere fluctuations in an open pit kiln.

  13. Automatic Detection and Distinction of Retinal Vessel Bifurcations and Crossings in Colour Fundus Photography

    Directory of Open Access Journals (Sweden)

    Harry Pratt

    2017-12-01

    Full Text Available The analysis of retinal blood vessels present in fundus images, and the addressing of problems such as blood clot location, is important to undertake accurate and appropriate treatment of the vessels. Such tasks are hampered by the challenge of accurately tracing back problems along vessels to their source. This is due to the unresolved issue of distinguishing automatically between vessel bifurcations and vessel crossings in colour fundus photographs. In this paper, we present a new technique for addressing this problem using a convolutional neural network approach to firstly locate vessel bifurcations and crossings and then to classifying them as either bifurcations or crossings. Our method achieves high accuracies for junction detection and classification on the DRIVE dataset and we show further validation on an unseen dataset from which no data has been used for training. Combined with work in automated segmentation, this method has the potential to facilitate: reconstruction of vessel topography, classification of veins and arteries and automated localisation of blood clots and other disease symptoms leading to improved management of eye disease.

  14. A study of reactor vessel integrity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hoon [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Kim, Jong Kyung; Shin, Chang Ho; Seo, Bo Kyun [Hanyang Univ., Seoul (Korea, Republic of)

    1999-02-15

    The fast neutron fluence at the Reactor Pressure Vessel(RPV) of KNGR designed for 60 years lifetime was calculated by full-scope Monte Carlo simulation for reactor vessel integrity assessment. KNGR core geometry was modeled on a three-dimensional representation of the one-sixteenth of the reactor in-vessel component. Each fuel assemblies were modeled explicitly, and each fuel pins were axially divided into 5 segments. The maximum flux of 4.3 x 10{sup 10} neutrons/cm{sup 2}. sec at the RPV was obtained by tallying neutrons crossing the beltline of inner surface of the RPV.

  15. Use of kurtosis for locating deep blood vessels in raw speckle imaging using a homogeneity representation

    Science.gov (United States)

    Peregrina-Barreto, Hayde; Perez-Corona, Elizabeth; Rangel-Magdaleno, Jose; Ramos-Garcia, Ruben; Chiu, Roger; Ramirez-San-Juan, Julio C.

    2017-06-01

    Visualization of deep blood vessels in speckle images is an important task as it is used to analyze the dynamics of the blood flow and the health status of biological tissue. Laser speckle imaging is a wide-field optical technique to measure relative blood flow speed based on the local speckle contrast analysis. However, it has been reported that this technique is limited to certain deep blood vessels (about ρ=300 μm) because of the high scattering of the sample; beyond this depth, the quality of the vessel's image decreases. The use of a representation based on homogeneity values, computed from the co-occurrence matrix, is proposed as it provides an improved vessel definition and its corresponding diameter. Moreover, a methodology is proposed for automatic blood vessel location based on the kurtosis analysis. Results were obtained from the different skin phantoms, showing that it is possible to identify the vessel region for different morphologies, even up to 900 μm in depth.

  16. Segmenting Retinal Blood Vessels With Deep Neural Networks.

    Science.gov (United States)

    Liskowski, Pawel; Krawiec, Krzysztof

    2016-11-01

    The condition of the vascular network of human eye is an important diagnostic factor in ophthalmology. Its segmentation in fundus imaging is a nontrivial task due to variable size of vessels, relatively low contrast, and potential presence of pathologies like microaneurysms and hemorrhages. Many algorithms, both unsupervised and supervised, have been proposed for this purpose in the past. We propose a supervised segmentation technique that uses a deep neural network trained on a large (up to 400[Formula: see text]000) sample of examples preprocessed with global contrast normalization, zero-phase whitening, and augmented using geometric transformations and gamma corrections. Several variants of the method are considered, including structured prediction, where a network classifies multiple pixels simultaneously. When applied to standard benchmarks of fundus imaging, the DRIVE, STARE, and CHASE databases, the networks significantly outperform the previous algorithms on the area under ROC curve measure (up to > 0.99) and accuracy of classification (up to > 0.97 ). The method is also resistant to the phenomenon of central vessel reflex, sensitive in detection of fine vessels ( sensitivity > 0.87 ), and fares well on pathological cases.

  17. Cutaneous Small Vessel Vasculitis Accompanied by Pustulosis Palmaris et Plantaris

    Directory of Open Access Journals (Sweden)

    Motoko Kosaka

    2012-03-01

    Full Text Available We present the case of a 64-year-old woman who has suffered from pustulosis palmaris et plantaris for 10 years. At the first examination, many erythematous lesions with purpura, blood crusts, and blisters were present in the lower legs and dorsum of the feet. Painful swelling in the sternal region and dorsal pain were also noted. Elevation of the CRP and myogenic enzyme levels, and liver and renal dysfunctions were noted on blood testing. Histopathologically, leukocytoclastic vasculitis was noted in small blood vessels in the whole dermal layers, and deposition of IgM and C3 in the vascular wall was detected by the direct immunofluorescence techniques. Based on these findings, cutaneous small vessel vasculitis was diagnosed. Because the patient complained of a toothache during the clinical course, an X-ray examination was performed. On pantomography, a radicular cyst and apical periodontitis were noted. The tooth symptoms changed with exacerbation and remission of the skin symptoms. These findings indicate that odontogenic infection is very likely to be a cause of cutaneous small vessel vasculitis in a manner similar to pustulosis palmaris et plantaris.

  18. ATLAS Supplier Award for the ECT Vacuum Vessels

    CERN Multimedia

    Jenni, P

    On 12 February the Netherlands firm Schelde Exotech was awarded the ATLAS Supplier Award for the construction of the two vacuum vessels for the ATLAS End- Cap Toroid (ECT) magnets. ATLAS Supplier Award ceremonies have now become something of a tradition. For the third consecutive year, ATLAS has given best supplier awards for the most exceptional contributors to the construction of the detector. The Netherlands firm Schelde Exotech has just received the award for the construction of the two vacuum vessels for the ECTs. With a diameter of 11 metres and a volume of 550 cubic metres, the ECT vacuum vessels are obviously impressive in scale. They consist of large aluminium plates and a stainless steel central bore tube. In order to obtain the required undulations, the firm had to develop a special assembly and welding technique. Despite the chambers' imposing size, a very high degree of precision has been achieved in their geometry. Moreover, the chambers, which were delivered in July 2002 to CERN, were built i...

  19. Molecular magnetic resonance imaging of atherosclerotic vessel wall disease

    Energy Technology Data Exchange (ETDEWEB)

    Noerenberg, Dominik [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); University of Munich - Grosshadern, Department of Clinical Radiology, Munich (Germany); Ebersberger, Hans U. [Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Diederichs, Gerd; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Botnar, Rene M. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Makowski, Marcus R. [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2016-03-15

    Molecular imaging aims to improve the identification and characterization of pathological processes in vivo by visualizing the underlying biological mechanisms. Molecular imaging techniques are increasingly used to assess vascular inflammation, remodeling, cell migration, angioneogenesis and apoptosis. In cardiovascular diseases, molecular magnetic resonance imaging (MRI) offers new insights into the in vivo biology of pathological vessel wall processes of the coronary and carotid arteries and the aorta. This includes detection of early vascular changes preceding plaque development, visualization of unstable plaques and assessment of response to therapy. The current review focuses on recent developments in the field of molecular MRI to characterise different stages of atherosclerotic vessel wall disease. A variety of molecular MR-probes have been developed to improve the non-invasive detection and characterization of atherosclerotic plaques. Specifically targeted molecular probes allow for the visualization of key biological steps in the cascade leading to the development of arterial vessel wall lesions. Early detection of processes which lead to the development of atherosclerosis and the identification of vulnerable atherosclerotic plaques may enable the early assessment of response to therapy, improve therapy planning, foster the prevention of cardiovascular events and may open the door for the development of patient-specific treatment strategies. (orig.)

  20. Development of advanced manufacturing technologies for low cost hydrogen storage vessels

    Energy Technology Data Exchange (ETDEWEB)

    Leavitt, Mark [Quantum Fuel Systems Technologies Worldwide, Inc., Irvine, CA (United States); Lam, Patrick [Boeing Research and Technology (BR& T), Seattle, WA (United States)

    2014-12-29

    The U.S. Department of Energy (DOE) defined a need for low-cost gaseous hydrogen storage vessels at 700 bar to support cost goals aimed at 500,000 units per year. Existing filament winding processes produce a pressure vessel that is structurally inefficient, requiring more carbon fiber for manufacturing reasons, than would otherwise be necessary. Carbon fiber is the greatest cost driver in building a hydrogen pressure vessel. The objective of this project is to develop new methods for manufacturing Type IV pressure vessels for hydrogen storage with the purpose of lowering the overall product cost through an innovative hybrid process of optimizing composite usage by combining traditional filament winding (FW) and advanced fiber placement (AFP) techniques. A numbers of vessels were manufactured in this project. The latest vessel design passed all the critical tests on the hybrid design per European Commission (EC) 79-2009 standard except the extreme temperature cycle test. The tests passed include burst test, cycle test, accelerated stress rupture test and drop test. It was discovered the location where AFP and FW overlap for load transfer could be weakened during hydraulic cycling at 85°C. To design a vessel that passed these tests, the in-house modeling software was updated to add capability to start and stop fiber layers to simulate the AFP process. The original in-house software was developed for filament winding only. Alternative fiber was also investigated in this project, but the added mass impacted the vessel cost negatively due to the lower performance from the alternative fiber. Overall the project was a success to show the hybrid design is a viable solution to reduce fiber usage, thus driving down the cost of fuel storage vessels. Based on DOE’s baseline vessel size of 147.3L and 91kg, the 129L vessel (scaled to DOE baseline) in this project shows a 32% composite savings and 20% cost savings when comparing Vessel 15 hybrid design and the Quantum

  1. Caribbean ST Croix Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels fishing in St. Croix. The catch and effort data for the entire trip are...

  2. Caribbean ST Thomas trap Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels fishing in St. Thomas. The catch and effort data for the entire trip are...

  3. 2013 Gulf of Mexico Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  4. 2013 Tug and Towing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  5. High Toughness Light Weight Pressure Vessel Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposed is a pressure vessel with 25% better Fracture Strength over equal strength designed Fiberglass to help reduce 10 to 25% weight for aerospace use. Phase I is...

  6. Large Pelagic Logbook Set Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch and effort for fishing trips that are taken by vessels with a Federal permit issued for the swordfish and sharks under the Highly...

  7. Caribbean Marine Mammal Assessment Vessel Surveys

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data sets are a compilation of large vessel surveys for marine mammal stock assessments in Caribbean waters conducted during 2000-2001. These surveys were...

  8. 2011 Pleasure Craft Sailing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  9. Atlantic Marine Mammal Assessment Vessel Surveys

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data sets are a compilation of large vessel surveys for marine mammal stock assessments in South Atlantic (Florida to Maryland) waters from 1994 to the...

  10. Large Pelagic Logbook Trip Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch and effort for fishing trips that are taken by vessels with a Federal permit issued for the swordfish and sharks under the Highly...

  11. 2011 Gulf of Mexico Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  12. 2013 Pleasure Craft and Sailing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  13. Ion transport membrane module and vessel system

    Energy Technology Data Exchange (ETDEWEB)

    Stein, VanEric Edward [Allentown, PA; Carolan, Michael Francis [Allentown, PA; Chen, Christopher M [Allentown, PA; Armstrong, Phillip Andrew [Orefield, PA; Wahle, Harold W [North Canton, OH; Ohrn, Theodore R [Alliance, OH; Kneidel, Kurt E [Alliance, OH; Rackers, Keith Gerard [Louisville, OH; Blake, James Erik [Uniontown, OH; Nataraj, Shankar [Allentown, PA; van Doorn, Rene Hendrik Elias (Obersulm-Willsbach, DE); Wilson, Merrill Anderson [West Jordan, UT

    2008-02-26

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel.The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  14. Ion transport membrane module and vessel system

    Energy Technology Data Exchange (ETDEWEB)

    Stein, VanEric Edward; Carolan, Michael Francis; Chen, Christopher M.; Armstrong, Phillip Andrew; Wahle, Harold W.; Ohrn, Theodore R.; Kneidel, Kurt E.; Rackers, Keith Gerard; Blake, James Erik; Nataraj, Shankar; van Doorn, Rene Hendrik Elias; Wilson, Merrill Anderson

    2007-02-20

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel. The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  15. Ion transport membrane module and vessel system

    Energy Technology Data Exchange (ETDEWEB)

    Stein, VanEric Edward [Allentown, PA; Carolan, Michael Francis [Allentown, PA; Chen, Christopher M [Allentown, PA; Armstrong, Phillip Andrew [Orefield, PA; Wahle, Harold W [North Canton, OH; Ohrn, Theodore R [Alliance, OH; Kneidel, Kurt E [Alliance, OH; Rackers, Keith Gerard [Louisville, OH; Blake, James Erik [Uniontown, OH; Nataraj, Shankar [Allentown, PA; Van Doorn, Rene Hendrik Elias (Obersulm-Willsbach, DE); Wilson, Merrill Anderson [West Jordan, UT

    2012-02-14

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel. The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  16. Design study: fishing vessel technical information system

    National Research Council Canada - National Science Library

    Park, C.H

    1979-01-01

    ... out. This study is primarily concerned with the design of a Fishing Vessel Technical Information System that will meet the requirements of the Department, and the determination of a schedule and means of data collection and management.

  17. LYMPHATIC VESSELS IN HEALTH AND DISEASE

    Science.gov (United States)

    Kesler, Cristina T.; Liao, Shan; Munn, Lance L.; Padera, Timothy P.

    2012-01-01

    The lymphatic vasculature plays vital roles in tissue fluid balance, immune defense, metabolism and cancer metastasis. In adults, lymphatic vessel formation and remodeling occurs primarily during inflammation, development of the corpus luteum, wound healing, and tumor growth. Unlike the blood circulation, where unidirectional flow is sustained by the pumping actions of the heart, pumping actions intrinsic to the lymphatic vessels themselves are important drivers of lymphatic flow. This review summarizes critical components that control lymphatic physiology. PMID:23209022

  18. Resistance of acrylic vessel to gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Andre Cavalcanti; Menezes, Maria Angela de B.C.; Pereira, Marcio Tadeu; Rocha, Nirlando Antonio; Vilela, Jefferson Jose, E-mail: andreccarneiro@gmail.com, E-mail: menezes@cdtn.br, E-mail: mtp@cdtn.br, E-mail: nar@cdtn.br, E-mail: jjv@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Braga, Mario Roberto Martins S.S., E-mail: mariomartins@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2013-07-01

    This paper describes the preliminary studies made in acrylic material in order to verify the effects of radiolysis in acrylic recipients in which the uranium ore standards are conditioned and check if the material is able to keep the {sup 222}Rn inside the vessel. The preliminary results after gamma irradiation of two kinds of recipients indicate no differences between the vessels irradiated and the ones no irradiated, related to color changes and tension resistance. (author)

  19. Interplay between Inflammatory Responses and Lymphatic Vessels.

    Science.gov (United States)

    Shin, Kihyuk; Lee, Seung-Hyo

    2014-08-01

    Lymphatic vessels are routes for leukocyte migration and fluid drainage. In addition to their passive roles in migration of leukocytes, increasing evidence indicates their active roles in immune regulation. Tissue inflammation rapidly induces lymphatic endothelial cell proliferation and chemokine production, thereby resulting in lymphangiogenesis. Furthermore, lymphatic endothelial cells induce T cell tolerance through various mechanisms. In this review, we focus on the current knowledge on how inflammatory cytokines affect lymphangiogenesis and the roles of lymphatic vessels in modulating immune responses.

  20. Transient evolution of inter vessel gap pressure due to relative thermal expansion between two vessels

    Science.gov (United States)

    Natesan, K.; Selvaraj, P.; Chellapandi, P.; Chetal, S. C.

    2002-08-01

    In a typical liquid metal cooled fast breeder reactor (LMFBR), a cylindrical sodium filled main vessel, which carries the internals such as reactor core, pumps, intermediate heat exchangers etc. is surrounded by another vessel called safety vessel. The inter vessel gap is filled with nitrogen. During a thermal transient in the pool sodium, because of the relative delay involved in the thermal diffusion between MV and SV, they are subjected to relative thermal expansion or contraction between them. This in turn results in pressurisation and depressurisation of inter vessel gap nitrogen respectively. In order to obtain the external pressurization for the buckling design of MV, transient thermal models for obtaining the evolutions of MV, SV and inter gap nitrogen temperatures and hence their relative thermal expansion and inter vessel gap pressure have been developed. This paper gives the details of the mathematical model, assumptions made in the calculation and the results of the analysis.

  1. Osteoid osteoma - the CT vessel sign

    Energy Technology Data Exchange (ETDEWEB)

    Yaniv, Gal; Shabshin, Noga; Sharon, Michal; Garniack, Alex [Sheba Medical Center, Dept. of Diagnostic Imaging, Tel Hashomer (Israel); Liberman, Boaz [Sheba Medical Center, Division of Orthopedics, Tel Hashomer, Sackler School of Medicine, Tel Aviv (Israel); Rimon, Uri [Sheba Medical Center, Dept. of Diagnostic Imaging, Tel Hashomer, Sackler School of Medicine, Tel Aviv (Israel); Eshed, Iris [Sheba Medical Center, Dept. of Diagnostic Imaging, Tel Hashomer, Tel Aviv University Sackler School of Medicine, Tel Aviv (Israel)

    2011-10-15

    To evaluate whether the presence of a feeding vessel in proximity to osteoid osteomas of long bones on multidetector CT (MDCT) can be an adjuvant clue for the diagnosis of osteoid osteoma. Forty-nine CT scans of patients with radiological and clinical diagnosis of osteoid osteoma of long bones and a control group of 20 CT scans of patients with cortical-based lesions other then osteoid osteoma were analyzed. Two radiologists evaluated the CT images in consensus for the presence of a blood vessel in the same axial slices in which the nidus of osteoid osteoma was seen and to determine the incidence. In 39 cases (79.6%) of osteoid osteoma, a blood vessel either entered the nidus (23 patients) or was seen in proximity to it (16 patients). This was significantly different (P<0.05) from the cortical-based lesions, in which only two CT scans (10%) showed a blood vessel in the lesion's proximity. In the majority of osteoid osteoma lesions in long bones, a blood vessel can be seen on MDCT either entering the nidus itself or in its proximity. The role of this vessel in the lesion pathogenesis and whether it improves diagnostic accuracy need further evaluation. (orig.)

  2. Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler.

    Science.gov (United States)

    Li, You Leo; Hyun, Dongwoon; Abou-Elkacem, Lotfi; Willmann, Juergen Karl; Dahl, Jeremy J

    2016-11-01

    Power Doppler (PD) imaging is a widely used technique for flow detection. Despite the wide use of Doppler ultrasound, limitations exist in the ability of Doppler ultrasound to assess slow flow in the small-diameter vasculature, such as the maternal spiral arteries and fetal villous arteries of the placenta and focal liver lesions. The sensitivity of PD in small vessel detection is limited by the low signal produced by slow flow and the noise associated with small vessels. The noise sources include electronic noise, stationary or slowly moving tissue clutter, reverberation clutter, and off-axis scattering from tissue, among others. In order to provide more sensitive detection of slow flow in small diameter vessels, a coherent flow imaging technique, termed coherent flow PD (CFPD), is characterized and evaluated with simulation, flow phantom experiment studies, and an in vivo animal small vessel detection study. CFPD imaging was introduced as a technique to detect slow blood flow. It has been demonstrated to detect slow flow below the detection threshold of conventional PD imaging using identical pulse sequences and filter parameters. In this paper, we compare CFPD with PD in the detection of blood flow in small-diameter vessels. The results from the study suggest that CFPD is able to provide a 7.5-12.5-dB increase in the signal-to-noise ratio (SNR) over PD images for the same physiological conditions and is less susceptible to reverberation clutter and thermal noise. Due to the increase in SNR, CFPD is able to detect small vessels in high channel noise cases, for which PD was unable to generate enough contrast to observe the vessel.

  3. Sustainable Oceanographic Vessels - Setting an Example

    Science.gov (United States)

    van Leer, J. C.

    2009-12-01

    In response to climate change, global warming and post “peak oil” fuel scarcity, the oceanographic community should consider reducing its carbon foot print. Why should scientists operate inefficient vessels while lecturing the general public on the need to reduce CO2 emissions? We have already seen curtailment of ship schedules and ship lay-ups, due in part to rising fuel costs, following $140/barrel crude oil. When the global recession ends, upward pressure on oil prices will again commence. Who can forecast how high fuel prices may ultimately rise during the typical 25-30 year lifetime of a research vessel? Are we to curtail future work at sea when oceanic climate research is becoming ever more important? A catamaran research vessel has been designed which can be electrically propelled from by a combination of high efficiency generators, photovoltaic panels and/or sails. Sail produced power is transformed with propellers and motor/generators into electric power which is stored in battery banks. This vessel could operate as the first true hybrid oceanographic research vessel. It could even continue operations without fuel in cases of a severe fuel shortage or fueling denial. Since the power produced by any water turbine increases with the cube of the velocity flowing over its propeller, the low fluid friction and high stability of a catamaran, with reasonably slender hulls, provide an important boost to efficient hybrid operation. The author has chartered a 42’ hybrid catamaran sailboat and found it efficient and extremely easy to operate and control. A 79’ motor sailing catamaran research vessel by Lock Crowther Designs will be presented as one example of a sustainable research vessel with excellent speed and sea-keeping. A center well makes operation as a small drilling/coring ship for coastal climate investigation possible. The center well also supports a host of remote sensing and robotic gear handling capabilities.

  4. Vessel discoloration detection in malarial retinopathy

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Barriga, S.; Soliz, P.; MacCormick, I.; Taylor, T.; Harding, S.; Lewallen, S.; Joshi, V.

    2016-03-01

    Cerebral malaria (CM) is a life-threatening clinical syndrome associated with malarial infection. It affects approximately 200 million people, mostly sub-Saharan African children under five years of age. Malarial retinopathy (MR) is a condition in which lesions such as whitening and vessel discoloration that are highly specific to CM appear in the retina. Other unrelated diseases can present with symptoms similar to CM, therefore the exact nature of the clinical symptoms must be ascertained in order to avoid misdiagnosis, which can lead to inappropriate treatment and, potentially, death. In this paper we outline the first system to detect the presence of discolored vessels associated with MR as a means to improve the CM diagnosis. We modified and improved our previous vessel segmentation algorithm by incorporating the `a' channel of the CIELab color space and noise reduction. We then divided the segmented vasculature into vessel segments and extracted features at the wall and in the centerline of the segment. Finally, we used a regression classifier to sort the segments into discolored and not-discolored vessel classes. By counting the abnormal vessel segments in each image, we were able to divide the analyzed images into two groups: normal and presence of vessel discoloration due to MR. We achieved an accuracy of 85% with sensitivity of 94% and specificity of 67%. In clinical practice, this algorithm would be combined with other MR retinal pathology detection algorithms. Therefore, a high specificity can be achieved. By choosing a different operating point in the ROC curve, our system achieved sensitivity of 67% with specificity of 100%.

  5. The influence of multidirectional vibrations on wound healing and on regeneration of blood- and lymph vessels.

    Science.gov (United States)

    Leduc, A; Lievens, P; Dewald, J

    1981-12-01

    Experiments show that the multidirectional vibration therapy is not an aggressive technique: when applied to the newly-formed lymph-vessels in the scar, we observed that they were not damaged by this technique whereas we had found in earlier studies that a gentle effleurage destructed the newly formed lymph network in the scar. When using this treatment, little or no adhesion of the scar to the underlying tissues is observed. There is a significant decrease of the local edema when compared to a standard group of wound-healing without multidirectional vibrations. There is also a significant decrease of general and local congestion and no increase in the permeability of veins and lymph vessels is present. The application of the local multidirectional vibration therapy accelerates the regeneration of the severed vein and lymph vessel.

  6. Tip Vortex Index (TVI) Technique for Inboard Propeller Noise Estimation

    OpenAIRE

    Sezen, Savaş; Dogrul, Ali; Bal, Şakir

    2018-01-01

    Cavitating marine propeller is one of the most dominant noise sources inmarine vessels.  The aim of this study isto examine the cavitating propeller noise induced by tip vortices for twinscrew passenger vessels. To determine the noise level inboard, tip vortex index(TVI) technique has been used. This technique is an approximate method based onnumerical and experimental data. In this study, it is aimed to predict theunderwater noise of a marine propeller by applying TVI technique for ...

  7. 50 CFR 654.6 - Vessel and gear identification.

    Science.gov (United States)

    2010-10-01

    ... Section 654.6 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC... enforcement vessel or aircraft. (ii) In block arabic numerals permanently affixed to or painted on the vessel... enforcement vessel or aircraft. (ii) In the form of a circle permanently affixed to or painted on the vessel...

  8. 46 CFR 153.9 - Foreign flag vessel endorsement application.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Foreign flag vessel endorsement application. 153.9... Foreign flag vessel endorsement application. (a) Application for a vessel whose flag administration is... endorsement from the cognizant Officer in Charge, Marine Inspection and have aboard the vessel copies of IMO...

  9. 46 CFR 356.17 - Annual requirements for vessel owners.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Annual requirements for vessel owners. 356.17 Section... DOCUMENTATION Requirements for Vessel Owners § 356.17 Annual requirements for vessel owners. (a) An owner of a... section. The vessel owner does not have to submit duplicate copies of documents that have already been...

  10. 46 CFR 169.307 - Plans for sister vessels.

    Science.gov (United States)

    2010-10-01

    ... Construction and Arrangement Plans § 169.307 Plans for sister vessels. Plans are not required for any vessel which is a sister ship to a vessel, provided that— (a) The approved plans for the original vessels are... new construction; (c) The regulations have not changed since the original plan approval; and (d) There...

  11. 46 CFR 184.115 - Applicability to existing vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Applicability to existing vessels. 184.115 Section 184... 100 GROSS TONS) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT General Provisions § 184.115 Applicability to existing vessels. (a) An existing vessel need not comply with §§ 184.402(c), 184.404, 184.410...

  12. 46 CFR 15.405 - Familiarity with vessel characteristics.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Familiarity with vessel characteristics. 15.405 Section... MANNING REQUIREMENTS Manning Requirements; All Vessels § 15.405 Familiarity with vessel characteristics. Each credentialed individual must become familiar with the relevant characteristics of the vessel on...

  13. Lymphatic vessels in osteoarthritic human knees.

    Science.gov (United States)

    Walsh, D A; Verghese, P; Cook, G J; McWilliams, D F; Mapp, P I; Ashraf, S; Wilson, D

    2012-05-01

    The distribution and function of lymphatic vessels in normal and diseased human knees are understood incompletely. This study aimed to investigate whether lymphatic density is associated with clinical, histological or radiographic parameters in osteoarthritis (OA). Sections of synovium from 60 knees from patients with OA were compared with 60 post mortem control knees (from 37 individuals). Lymphatic vessels were identified using immunohistochemistry for podoplanin, and quantified as lymphatic vessel density (LVD) and lymphatic endothelial cell (LEC) fractional area. Effusion status was determined by clinical examination, radiographs were scored for OA changes, and inflammation grading used haematoxylin and eosin stained sections of synovium. Lymphatic vessels were present in synovia from both disease groups, but were not identified in subchondral bone. Synovial lymphatic densities were independent of radiological severity and age. Synovia from patients with OA displayed lower LVD (z=-3.4, P=0.001) and lower LEC fractional areas (z=-4.5, Plymphatics and OA/effusion appeared to be independent of other measured confounders. Lymphatic vessels are present in lower densities in OA synovia. Abnormalities of synovial fluid drainage may confound the value of effusion as a clinical sign of synovitis in OA. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  14. Deaths Related to Vessel Injuries in Extremities

    Directory of Open Access Journals (Sweden)

    Nursel Türkmen

    2003-12-01

    Full Text Available Lethal or non-lethal extremity injuries are often seen in medico-legal practice. In this study, we planned to investigate medico-legal properties of deaths related to vessel injuries in extremities. In forensic autopsies performed in Bursa, we examined total 4242 autopsy reports between 1996-2003 in included 40 (0,94% cases of deaths caused by vessel injuries in extremities. 90% of cases were male with median age 35.87 (17-66. Stabbing device account for 60% of injuries. Most frequent injuries were in femoral artery and branches. In 82.5% of cases, homicide was the origin of death. In 30% of cases, mean 159.33 mg/dl alcohol blood concentration was detected. In the scene investigation reports, 47.5% of documented incidents were outdoor and 47.5% of the cases died in the scene. As a conclusion, it is observed that alcoholic males of middle age are the risk group for vascular injuries in extremities. In the deaths related to isolated vessel injuries in extremities, the detection of injured vessel, localisation and number of total and lethal wounds would offer a solution for the evil intent; and as in the other violent death cases autopsy is required in the deaths due to vessel injuries in extremities. Key words: Vascular injuries, Extremity, Forensic autopsy.

  15. Lymphatic vessel density and function in experimental bladder cancer

    Directory of Open Access Journals (Sweden)

    Maier Julie

    2007-11-01

    Full Text Available Abstract Background The lymphatics form a second circulatory system that drains the extracellular fluid and proteins from the tumor microenvironment, and provides an exclusive environment in which immune cells interact and respond to foreign antigen. Both cancer and inflammation are known to induce lymphangiogenesis. However, little is known about bladder lymphatic vessels and their involvement in cancer formation and progression. Methods A double transgenic mouse model was generated by crossing a bladder cancer-induced transgenic, in which SV40 large T antigen was under the control of uroplakin II promoter, with another transgenic mouse harboring a lacZ reporter gene under the control of an NF-κB-responsive promoter (κB-lacZ exhibiting constitutive activity of β-galactosidase in lymphatic endothelial cells. In this new mouse model (SV40-lacZ, we examined the lymphatic vessel density (LVD and function (LVF during bladder cancer progression. LVD was performed in bladder whole mounts and cross-sections by fluorescent immunohistochemistry (IHC using LYVE-1 antibody. LVF was assessed by real-time in vivo imaging techniques using a contrast agent (biotin-BSA-Gd-DTPA-Cy5.5; Gd-Cy5.5 suitable for both magnetic resonance imaging (MRI and near infrared fluorescence (NIRF. In addition, IHC of Cy5.5 was used for time-course analysis of co-localization of Gd-Cy5.5 with LYVE-1-positive lymphatics and CD31-positive blood vessels. Results SV40-lacZ mice develop bladder cancer and permitted visualization of lymphatics. A significant increase in LVD was found concomitantly with bladder cancer progression. Double labeling of the bladder cross-sections with LYVE-1 and Ki-67 antibodies indicated cancer-induced lymphangiogenesis. MRI detected mouse bladder cancer, as early as 4 months, and permitted to follow tumor sizes during cancer progression. Using Gd-Cy5.5 as a contrast agent for MRI-guided lymphangiography, we determined a possible reduction of lymphatic

  16. Modeling the microclimate inside a vessel in in vitro culture : vessel ...

    African Journals Online (AJOL)

    Numerical simulations show that variations in vessel internal humidity was sensitive to transfer coefficient, climatic conditions within the growth chamber, evaporation and condensation of water vapor on the walls of the vessel. The variations in water vapor pressure deficits (VPD) (low during the nyctiperiod and high during ...

  17. 40 CFR 1042.650 - Exemptions for migratory vessels and auxiliary engines on Category 3 vessels.

    Science.gov (United States)

    2010-07-01

    ... International Convention for the Protection of Life at Sea (SOLAS). The vessel owner must maintain compliance.... (b) SOLAS exemption. We may approve a permanent exemption from the prohibitions in 40 CFR 1068.101(a... 40 CFR 1042.650 AND IS FOR USE SOLELY IN SOLAS VESSELS. INSTALLATION OR USE OF THIS ENGINE IN ANY...

  18. Smooth muscle cell recruitment to lymphatic vessels requires PDGFB and impacts vessel size but not identity.

    Science.gov (United States)

    Wang, Yixin; Jin, Yi; Mäe, Maarja Andaloussi; Zhang, Yang; Ortsäter, Henrik; Betsholtz, Christer; Mäkinen, Taija; Jakobsson, Lars

    2017-10-01

    Tissue fluid drains through blind-ended lymphatic capillaries, via smooth muscle cell (SMC)-covered collecting vessels into venous circulation. Both defective SMC recruitment to collecting vessels and ectopic recruitment to lymphatic capillaries are thought to contribute to vessel failure, leading to lymphedema. However, mechanisms controlling lymphatic SMC recruitment and its role in vessel maturation are unknown. Here, we demonstrate that platelet-derived growth factor B (PDGFB) regulates lymphatic SMC recruitment in multiple vascular beds. PDGFB is selectively expressed by lymphatic endothelial cells (LECs) of collecting vessels. LEC-specific deletion of Pdgfb prevented SMC recruitment causing dilation and failure of pulsatile contraction of collecting vessels. However, vessel remodelling and identity were unaffected. Unexpectedly, Pdgfb overexpression in LECs did not induce SMC recruitment to capillaries. This was explained by the demonstrated requirement of PDGFB extracellular matrix (ECM) retention for lymphatic SMC recruitment, and the low presence of PDGFB-binding ECM components around lymphatic capillaries. These results demonstrate the requirement of LEC-autonomous PDGFB expression and retention for SMC recruitment to lymphatic vessels, and suggest an ECM-controlled checkpoint that prevents SMC investment of capillaries, which is a common feature in lymphedematous skin. © 2017. Published by The Company of Biologists Ltd.

  19. Smooth muscle cell recruitment to lymphatic vessels requires PDGFB and impacts vessel size but not identity

    Science.gov (United States)

    Wang, Yixin; Jin, Yi; Mäe, Maarja Andaloussi; Zhang, Yang; Ortsäter, Henrik; Betsholtz, Christer; Mäkinen, Taija

    2017-01-01

    Tissue fluid drains through blind-ended lymphatic capillaries, via smooth muscle cell (SMC)-covered collecting vessels into venous circulation. Both defective SMC recruitment to collecting vessels and ectopic recruitment to lymphatic capillaries are thought to contribute to vessel failure, leading to lymphedema. However, mechanisms controlling lymphatic SMC recruitment and its role in vessel maturation are unknown. Here, we demonstrate that platelet-derived growth factor B (PDGFB) regulates lymphatic SMC recruitment in multiple vascular beds. PDGFB is selectively expressed by lymphatic endothelial cells (LECs) of collecting vessels. LEC-specific deletion of Pdgfb prevented SMC recruitment causing dilation and failure of pulsatile contraction of collecting vessels. However, vessel remodelling and identity were unaffected. Unexpectedly, Pdgfb overexpression in LECs did not induce SMC recruitment to capillaries. This was explained by the demonstrated requirement of PDGFB extracellular matrix (ECM) retention for lymphatic SMC recruitment, and the low presence of PDGFB-binding ECM components around lymphatic capillaries. These results demonstrate the requirement of LEC-autonomous PDGFB expression and retention for SMC recruitment to lymphatic vessels, and suggest an ECM-controlled checkpoint that prevents SMC investment of capillaries, which is a common feature in lymphedematous skin. PMID:28851707

  20. Intravital two-photon microscopy of immune cell dynamics in corneal lymphatic vessels.

    Directory of Open Access Journals (Sweden)

    Philipp Steven

    Full Text Available BACKGROUND: The role of lymphatic vessels in tissue and organ transplantation as well as in tumor growth and metastasis has drawn great attention in recent years. METHODOLOGY/PRINCIPAL FINDINGS: We now developed a novel method using non-invasive two-photon microscopy to simultaneously visualize and track specifically stained lymphatic vessels and autofluorescent adjacent tissues such as collagen fibrils, blood vessels and immune cells in the mouse model of corneal neovascularization in vivo. The mouse cornea serves as an ideal tissue for this technique due to its easy accessibility and its inducible and modifiable state of pathological hem- and lymphvascularization. Neovascularization was induced by suture placement in corneas of Balb/C mice. Two weeks after treatment, lymphatic vessels were stained intravital by intrastromal injection of a fluorescently labeled LYVE-1 antibody and the corneas were evaluated in vivo by two-photon microscopy (TPM. Intravital TPM was performed at 710 nm and 826 nm excitation wavelengths to detect immunofluorescence and tissue autofluorescence using a custom made animal holder. Corneas were then harvested, fixed and analyzed by histology. Time lapse imaging demonstrated the first in vivo evidence of immune cell migration into lymphatic vessels and luminal transport of individual cells. Cells immigrated within 1-5.5 min into the vessel lumen. Mean velocities of intrastromal corneal immune cells were around 9 µm/min and therefore comparable to those of T-cells and macrophages in other mucosal surfaces. CONCLUSIONS: To our knowledge we here demonstrate for the first time the intravital real-time transmigration of immune cells into lymphatic vessels. Overall this study demonstrates the valuable use of intravital autofluorescence two-photon microscopy in the model of suture-induced corneal vascularizations to study interactions of immune and subsequently tumor cells with lymphatic vessels under close as possible

  1. Ultrafast high-resolution in vivo volume-CTA of mice cerebral vessels.

    Science.gov (United States)

    Schambach, Sebastian J; Bag, Simona; Steil, Volker; Isaza, Cristina; Schilling, Lothar; Groden, Christoph; Brockmann, Marc A

    2009-04-01

    Animal models developed in rats and mice have become indispensable in preclinical cerebrovascular research. Points of interest include the investigation of the vascular bed and the morphology and function of the arterial, capillary, and venous vessels. Because of their extremely small caliber, in vivo examination of these vessels is extremely difficult. In the present study we have developed a method to provide fast 3D in vivo analysis of cerebral murine vessels using volume computed tomography-angiography (vCTA). Using an industrial X-ray inspection system equipped with a multifocus cone beam X-ray source and a 12-bit direct digital flatbed detector, high-speed vCTA (180 degrees rotation in 40 s. at 30 fps) was performed in anesthetized mice. During the scan an iodinated contrast agent was infused via a tail vein. Images were reconstructed using a filtered backprojection algorithm. Image analysis was performed by maximum intensity projection (MIP) and 3D volume reconstruction. All mice tolerated i.v. injection of the iodinated contrast agent well. Smallest achievable voxel size of raw data while scanning the whole neurocranium was 16 mum. Anatomy of cerebral vessels was assessable in all animals, and anatomic differences between mouse strains could easily be detected. Mean vessel diameter was measured in C57BL/6 and BALBc mice. Changes of vessel caliber were assessable by repeated vCTA. Ultra fast in vivo vCTA of murine cerebral vasculature is feasible at resolutions down to 16 mum. The technique allows the assessment of vessel caliber changes in living mice, thus providing an interesting tool to monitor different features such as vasospasm or vessel patency.

  2. Nonlinear retinal image enhancement for vessel detection

    Science.gov (United States)

    Wang, Xiaohong; Jiang, Xudong

    2017-07-01

    Retinal vessel detection is an essential part of the computer-aided diagnosis of eye diseases. Due to non-perfect imaging environment, retinal images often appear with intensity variations and artificial noises. This work proposes a two-step nonlinear retinal image enhancement to compensate for those imperfections of retinal images. The first step reduces intensity fluctuations of the image and the second step attenuates impulsive noise while preserving retinal vessels. Classification on the feature vector extracted from the enhanced retinal images is performed by using a linear SVM classifier. Experimental results demonstrate that the proposed method of two-step nonlinear image enhancement visibly improves the vessel detection performance, achieving better accuracy than that without enhancement process on the both DRIVE and STARE databases.

  3. [Large vessels vasculopathy in systemic sclerosis].

    Science.gov (United States)

    Tejera Segura, Beatriz; Ferraz-Amaro, Iván

    2015-12-07

    Vasculopathy in systemic sclerosis is a severe, in many cases irreversible, manifestation that can lead to amputation. While the classical clinical manifestations of the disease have to do with the involvement of microcirculation, proximal vessels of upper and lower limbs can also be affected. This involvement of large vessels may be related to systemic sclerosis, vasculitis or atherosclerotic, and the differential diagnosis is not easy. To conduct a proper and early diagnosis, it is essential to start prompt appropriate treatment. In this review, we examine the involvement of large vessels in scleroderma, an understudied manifestation with important prognostic and therapeutic implications. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  4. Variation and treatment of vessels in laparoscopic right hemicolectomy.

    Science.gov (United States)

    Ye, Kai; Lin, Jianan; Sun, Yafeng; Wu, Yiyang; Xu, Jianhua; He, Songbing

    2018-03-01

    With the introduction of complete mesocolic excision (CME) and the application of laparoscopic technique, surgery for colon cancer has become more standardized and the curative effect has improved [1]. The key points in laparoscopic right hemicolectomy are high ligation of main vessels and root dissection of lymph nodes. The wide range of variations in vascular architecture and intraoperative bleeding are common causes of prolonged surgical time, wound hemorrhage, and even transfer to the opening operation. The superior mesenteric vein (SMV) is the most important anatomical landmark in CME for the right colon, and guides all the steps of lymph node dissection. The SMV appears as a pale blue bulge on laparoscopy, which enables accurate positioning. The ileocolic vessel pedicle is relatively constant and facilitates accurate positioning. The intersection of the ileocolic vessel pedicle and the SMV is the optimal starting point in laparoscopic right hemicolectomy using a medial-to-lateral approach. A sheath with an avascular plane can be reached after opening the SMV vascular sheath, which results in less bleeding and enables vascular root and thorough lymph node dissection. The first step is to manage the ileocolic vessels. The ileocolic artery (ICA) is located anterior to the ileocolic vein (ICV) for about one-third of the incidence. The ileocolic vessels are relatively long and are easy to work with. In the vast majority of cases, the ICV drains into the SMV, and into the gastrocolic trunk (GCT) in about 2.5% of cases. The reported incidence of a right colic artery (RCA) is controversial; the RCA is absent in about 50% of cases and often crosses the SMV. The right colic vein (RCV) usually drains into the GCT, but sometimes drains directly into the SMV. The middle colic vessels have great variability and a close anatomical relationship with the pancreas, duodenum, and GCT. Moreover, the transverse colon and mesentery are long, and root positioning and processing of

  5. Academic Research Vessels 1985-1990.

    Science.gov (United States)

    1982-01-01

    of them MVC ). Recommnendati ons. * Complete reliance of the academic community on non-academic vessels should be avoided, since such vessels are not...responsible for management of a major fishery on the Bering Sea shelf. This area is covered by ice much of the year. With the spring melting of the ice is...of the group. 5. Meetings of the group shall normally be held four times yearly in- *1 cluding spring and fall semi-annual UNOLS meetings, and at

  6. Polymethylmethacrylate extrusion into the femoral nutrient vessel during arthroplasty: A phenomenon to be aware of

    Directory of Open Access Journals (Sweden)

    Steve Eastaugh-Waring

    2009-01-01

    Full Text Available Third generation cementing technique is now commonly used for total hip arthroplasty. The aim of this technique is to sufficiently pressurise the cement and allow maximal penetration of the cement into any remaining trabecular bone to provide a stable fixation of the prosthesis. We report a case where this pressurisation resulted in Polymethylmethacrylate retrograde filling of the nutrient vessel and we discuss the controversial diagnosis and current literature surrounding this rare phenomenon.

  7. Experimental techniques; Techniques experimentales

    Energy Technology Data Exchange (ETDEWEB)

    Roussel-Chomaz, P. [GANIL CNRS/IN2P3, CEA/DSM, 14 - Caen (France)

    2007-07-01

    This lecture presents the experimental techniques, developed in the last 10 or 15 years, in order to perform a new class of experiments with exotic nuclei, where the reactions induced by these nuclei allow to get information on their structure. A brief review of the secondary beams production methods will be given, with some examples of facilities in operation or under project. The important developments performed recently on cryogenic targets will be presented. The different detection systems will be reviewed, both the beam detectors before the targets, and the many kind of detectors necessary to detect all outgoing particles after the reaction: magnetic spectrometer for the heavy fragment, detection systems for the target recoil nucleus, {gamma} detectors. Finally, several typical examples of experiments will be detailed, in order to illustrate the use of each detector either alone, or in coincidence with others. (author)

  8. Calcification of intracranial vessels in neurocysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Bouzas, A. [ENEP Iztacala, Universidad Nacional Autonoma de Mexico, Mexico (Mexico); Ballesteros-Maresma, A. [Radiologia Clinica de Cuernavaca (Mexico); Casian, G.; Hernandez-Martinez, P. [Hospital Juarez de Mexico S. S. (Mexico); Martinez-Lopez, M. [Fundacion Clinica Medica Sur (Mexico)

    2000-07-01

    We report calcification of intracranial vessels in neurocysticercosis. Calcification was observed in the middle cerebral arteries in two patients, and the circle of Willis in two others. The patients with middle cerebral artery calcification underwent CT with inhaled stable xenon and an area of mild hypoperfusion was observed in the ipsilateral cerebral hemisphere. (orig.)

  9. Hereditary cerebral small vessel disease and stroke.

    Science.gov (United States)

    Søndergaard, Christian Baastrup; Nielsen, Jørgen Erik; Hansen, Christine Krarup; Christensen, Hanne

    2017-04-01

    Cerebral small vessel disease is considered hereditary in about 5% of patients and is characterized by lacunar infarcts and white matter hyperintensities on MRI. Several monogenic hereditary diseases causing cerebral small vessel disease and stroke have been identified. The purpose of this systematic review is to provide a guide for determining when to consider molecular genetic testing in patients presenting with small vessel disease and stroke. CADASIL, CARASIL, collagen type IV mutations (including PADMAL), retinal vasculopathy with cerebral leukodystrophy, Fabry disease, hereditary cerebral hemorrhage with amyloidosis, and forkhead box C1 mutations are described in terms of genetics, pathology, clinical manifestation, imaging, and diagnosis. These monogenic disorders are often characterized by early-age stroke, but also by migraine, mood disturbances, vascular dementia and often gait disturbances. Some also present with extra-cerebral manifestations such as microangiopathy of the eyes and kidneys. Many present with clinically recognizable syndromes. Investigations include a thorough family medical history, medical history, neurological examination, neuroimaging, often supplemented by specific examinations e.g of the of vision, retinal changes, as well as kidney and heart function. However molecular genetic analysis is the final gold standard of diagnosis. There are increasing numbers of reports on new monogenic syndromes causing cerebral small vessel disease. Genetic counseling is important. Enzyme replacement therapy is possible in Fabry disease, but treatment options remain overall very limited. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Bilateral Variations of the Testicular Vessels: Embryological ...

    African Journals Online (AJOL)

    Bilateral Variations of the Testicular Vessels: Embryological Background and Clinical Implications. Yogesh Diwan, Rikki Singal1, Deepa Diwan, Subhash Goyal1, Samita Singal2, Mausam Kapil1. Department of Anatomy, Indira Gandhi Medical College, Shimla, 1Surgery and 2Radiology, Maharishi Markandeshwer Institute ...

  11. Joint High Speed Vessel (JHSV) Program

    Science.gov (United States)

    2007-05-23

    OPERATIONALY throughout the world • EUCOM – Norway to Africa • CENTCOM • PACOM • SOUTHCOM • CONUS • Leased vessels have undergone significant sea trials and... Austral ia to the Persian Gul f to support C E N T C O M t a s k i n g s JOINT VENTURE SWIFT 22 UNCLASSIFIED UNCLASSIFIED Acquisition Constraints

  12. Liquid Nitrogen Subcooler Pressure Vessel Engineering Note

    Energy Technology Data Exchange (ETDEWEB)

    Rucinski, R.; /Fermilab

    1997-04-24

    The normal operating pressure of this dewar is expected to be less than 15 psig. This vessel is open to atmospheric pressure thru a non-isolatable vent line. The backpressure in the vent line was calculated to be less than 1.5 psig at maximum anticipated flow rates.

  13. 50 CFR 300.13 - Vessel permits.

    Science.gov (United States)

    2010-10-01

    ... vessel undermined the effectiveness of international conservation and management measures, and the new... special product or service. The fee is specified with the application form. The appropriate fee must... applicant of any deficiency in the application. (f) Validity. Permits issued under this subpart are valid...

  14. 78 FR 63235 - Tank Vessel Oil Transfers

    Science.gov (United States)

    2013-10-23

    ... engaged in oil transfer operations? 12. Are there conflicts or areas of improvement with regard to... SECURITY Coast Guard Tank Vessel Oil Transfers AGENCY: Coast Guard, DHS. ACTION: Notice and request for comments. SUMMARY: The Coast Guard announces that it is considering new measures to reduce the risks of oil...

  15. 78 FR 14053 - Vessel Documentation Renewal Fees

    Science.gov (United States)

    2013-03-04

    ... the comment, if submitted on behalf of an association, business, labor union, etc.). You may review a... effects, distributive impacts, and equity). Executive Order 13563 emphasizes the importance of quantifying... additional costs due to increased need in labor and capital costs, would cost each vessel owner $26 per...

  16. 76 FR 49975 - Inspection of Towing Vessels

    Science.gov (United States)

    2011-08-11

    ... related materials. All comments received will be posted, without change, to http://www.regulations.gov and... comments and material received during the comment period and may change this proposed rule based on your... consideration its size, organizational structure, and vessel types and services. Towing Safety Management System...

  17. 78 FR 38102 - Passenger Vessels Accessibility Guidelines

    Science.gov (United States)

    2013-06-25

    ... vessels a limited use-limited application elevator (LULA) or platform lift, would be required to connect..., we estimate an elevator to cost $371,000; a LULA to cost $297,400; and a platform lift to cost $108.... See 42 U.S.C. 12101 et seq. Title II of the ADA applies to state and local governments and Title III...

  18. Sensitivity coefficients for the stochastic estimation of the radiation damage to the reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, C.M.; Hernandez Valle, S. [Centro de Investigaciones Tecnologicas, Nucleares y Ambientales, La Habana (Cuba). E-mail: calvarez@ctn.isctn.edu.cu; svalle@ctn.isctn.edu.cu

    2000-07-01

    The construction of the sensitivity matrix in the case of the vessel radiation damage estimation by Monte Carlo techniques poses new problems related to the uncertainties of the obtained responses. In the case of deterministic calculations, the sensitivity coefficient obtention is a straightforward procedure based on the perturbation formalism through the calculation of the adjoint fluxes. In the paper an alternative procedure implementation based on the differential operator method is described with the modifications needed to the used HEXANN-EVALU code for the response estimations in the VVER-440 pressure vessel. (author)

  19. Effect of Rolling Massage on the Vortex Flow in Blood Vessels with Lattice Boltzmann Simulation

    Science.gov (United States)

    Yi, Hou Hui

    The rolling massage manipulation is a classic Chinese Medical Massage, which is a nature therapy in eliminating many diseases. Here, the effect of the rolling massage on the cavity flows in blood vessel under the rolling manipulation is studied by the lattice Boltzmann simulation. The simulation results show that the vortex flows are fully disturbed by the rolling massage. The flow behavior depends on the rolling velocity and the rolling depth. Rolling massage has a better effect on the flows in the cavity than that of the flows in a planar blood vessel. The result is helpful to understand the mechanism of the massage and develop the rolling techniques.

  20. An automated method for accurate vessel segmentation

    Science.gov (United States)

    Yang, Xin; Liu, Chaoyue; Le Minh, Hung; Wang, Zhiwei; Chien, Aichi; (Tim Cheng, Kwang-Ting

    2017-05-01

    Vessel segmentation is a critical task for various medical applications, such as diagnosis assistance of diabetic retinopathy, quantification of cerebral aneurysm’s growth, and guiding surgery in neurosurgical procedures. Despite technology advances in image segmentation, existing methods still suffer from low accuracy for vessel segmentation in the two challenging while common scenarios in clinical usage: (1) regions with a low signal-to-noise-ratio (SNR), and (2) at vessel boundaries disturbed by adjacent non-vessel pixels. In this paper, we present an automated system which can achieve highly accurate vessel segmentation for both 2D and 3D images even under these challenging scenarios. Three key contributions achieved by our system are: (1) a progressive contrast enhancement method to adaptively enhance contrast of challenging pixels that were otherwise indistinguishable, (2) a boundary refinement method to effectively improve segmentation accuracy at vessel borders based on Canny edge detection, and (3) a content-aware region-of-interests (ROI) adjustment method to automatically determine the locations and sizes of ROIs which contain ambiguous pixels and demand further verification. Extensive evaluation of our method is conducted on both 2D and 3D datasets. On a public 2D retinal dataset (named DRIVE (Staal 2004 IEEE Trans. Med. Imaging 23 501-9)) and our 2D clinical cerebral dataset, our approach achieves superior performance to the state-of-the-art methods including a vesselness based method (Frangi 1998 Int. Conf. on Medical Image Computing and Computer-Assisted Intervention) and an optimally oriented flux (OOF) based method (Law and Chung 2008 European Conf. on Computer Vision). An evaluation on 11 clinical 3D CTA cerebral datasets shows that our method can achieve 94% average accuracy with respect to the manual segmentation reference, which is 23% to 33% better than the five baseline methods (Yushkevich 2006 Neuroimage 31 1116-28; Law and Chung 2008

  1. AAV vector encoding human VEGF165–transduced pectineus muscular flaps increase the formation of new tissue through induction of angiogenesis in an in vivo chamber for tissue engineering: A technique to enhance tissue and vessels in microsurgically engineered tissue

    Directory of Open Access Journals (Sweden)

    Silvia Moimas

    2015-12-01

    Full Text Available In regenerative medicine, new approaches are required for the creation of tissue substitutes, and the interplay between different research areas, such as tissue engineering, microsurgery and gene therapy, is mandatory. In this article, we report a modification of a published model of tissue engineering, based on an arterio-venous loop enveloped in a cross-linked collagen–glycosaminoglycan template, which acts as an isolated chamber for angiogenesis and new tissue formation. In order to foster tissue formation within the chamber, which entails on the development of new vessels, we wondered whether we might combine tissue engineering with a gene therapy approach. Based on the well-described tropism of adeno-associated viral vectors for post-mitotic tissues, a muscular flap was harvested from the pectineus muscle, inserted into the chamber and transduced by either AAV vector encoding human VEGF165 or AAV vector expressing the reporter gene β-galactosidase, as a control. Histological analysis of the specimens showed that muscle transduction by AAV vector encoding human VEGF165 resulted in enhanced tissue formation, with a significant increase in the number of arterioles within the chamber in comparison with the previously published model. Pectineus muscular flap, transduced by adeno-associated viral vectors, acted as a source of the proangiogenic factor vascular endothelial growth factor, thus inducing a consistent enhancement of vessel growth into the newly formed tissue within the chamber. In conclusion, our present findings combine three different research fields such as microsurgery, tissue engineering and gene therapy, suggesting and showing the feasibility of a mixed approach for regenerative medicine.

  2. Brain Vascular Imaging Techniques

    Directory of Open Access Journals (Sweden)

    Bàrbara Laviña

    2016-12-01

    Full Text Available Recent major improvements in a number of imaging techniques now allow for the study of the brain in ways that could not be considered previously. Researchers today have well-developed tools to specifically examine the dynamic nature of the blood vessels in the brain during development and adulthood; as well as to observe the vascular responses in disease situations in vivo. This review offers a concise summary and brief historical reference of different imaging techniques and how these tools can be applied to study the brain vasculature and the blood-brain barrier integrity in both healthy and disease states. Moreover, it offers an overview on available transgenic animal models to study vascular biology and a description of useful online brain atlases.

  3. Role of arginase in vessel wall remodeling

    Directory of Open Access Journals (Sweden)

    William eDurante

    2013-05-01

    Full Text Available Arginase metabolizes the semi-essential amino acid L-arginine to L-ornithine and urea. There are two distinct isoforms of arginase, arginase I and II, which are encoded by separate genes and display differences in tissue distribution, subcellular localization, and molecular regulation. Blood vessels express both arginase I and II but their distribution appears to be cell-, vessel-, and species-specific. Both isoforms of arginase are induced by numerous pathologic stimuli and contribute to vascular cell dysfunction and vessel wall remodeling in several diseases. Clinical and experimental studies have documented increases in the expression and/or activity of arginase I or II in blood vessels following arterial injury and in pulmonary and arterial hypertension, aging, and atherosclerosis. Significantly, pharmacological inhibition or genetic ablation of arginase in animals ameliorates abnormalities in vascular cells and normalizes blood vessel architecture and function in all of these pathological states. The detrimental effect of arginase in vascular remodeling is attributable to its ability to stimulate vascular smooth muscle cell and endothelial cell proliferation, and collagen deposition by promoting the synthesis of polyamines and L-proline, respectively. In addition, arginase adversely impacts arterial remodeling by directing macrophages towards an inflammatory phenotype. Moreover, the proliferative, fibrotic, and inflammatory actions of arginase in the vasculature are further amplified by its capacity to inhibit nitric oxide synthesis by competing with nitric oxide synthase for substrate, L-arginine. Pharmacologic or molecular approaches targeting specific isoforms of arginase represent a promising strategy in treating obstructive fibroproliferative vascular disease.

  4. Computerized Reconstruction of Pulpal Blood Vessels Examined under Confocal Microscope

    Directory of Open Access Journals (Sweden)

    Digka Anna

    2015-03-01

    Full Text Available The purpose of this study was the evaluation of 3 different histological methods for studying pulpal blood vessels in combination with 2 types of confocal microscope and computer assisted 3-dimensional reconstruction. 10 human, healthy, free of restorations or caries teeth that were extracted for orthodontic reasons were used. From these teeth, the pulp tissues of 5 were removed, fixed in formalin solution, dehydrated and embedded in paraffin. Serial cross sections 5μm thick were taken from 3 of the above mentioned pulpal tissues and stained with CD34 according to the immunohistochemical ABC technique, while the rest 2 were stained with CD34 and Cy5 by means of immunofluorescence after serial cross sectioning of 10μm. 5 of the 10 teeth were fixed, decalcified, serial cross sectioned (30μm thickness and stained with eosin. The physical sections were examined under 2 types of confocal laser microscope. Serial images were taken for each section, alignment of the images was followed and finally 3-dimensional reconstructions of the pulpal vessels were achieved.

  5. War injuries of the blood vessels of the extremities

    Directory of Open Access Journals (Sweden)

    Radulović Svetozar

    2002-01-01

    Full Text Available Treatment results of 200 injured with the lesions of 282 magisterial blood vessels were analyzed. All were combat injuries, and the majority was caused by the fragments of explosive device. The mechanism of such the injuries produced large defects of soft tissues as well as the high level of the wound contamination, which aggravated reconstructive procedures and increased the risk of infection. In the majority of cases anatomic reconstruction of the artery was performed, and the ligature was used only in the case of graft infection and in the injuries of one artery of the lower leg or the forearm. The majority of injuries was solved by lateral suture or patch plastic, since postoperative constriction caused by those methods did not cause greater hemodynamic disorders due to the size of venous lumen. The duration of ischemic interval was of the utmost importance for the favorable final result of the treatment, as well as the adequate debridement of the wound, good soft-tissue cover of the reconstructed blood vessel and precise a traumatic technique. Total percentage of amputations was 14.5%, and all were involving the lower extremities, and were mostly caused by popliteal artery lesion.

  6. Polymer-based blood vessel models with micro-temperature sensors in EVE

    Science.gov (United States)

    Mizoshiri, Mizue; Ito, Yasuaki; Hayakawa, Takeshi; Maruyama, Hisataka; Sakurai, Junpei; Ikeda, Seiichi; Arai, Fumihito; Hata, Seiichi

    2017-04-01

    Cu-based micro-temperature sensors were directly fabricated on poly(dimethylsiloxane) (PDMS) blood vessel models in EVE using a combined process of spray coating and femtosecond laser reduction of CuO nanoparticles. CuO nanoparticle solution coated on a PDMS blood vessel model are thermally reduced and sintered by focused femtosecond laser pulses in atmosphere to write the sensors. After removing the non-irradiated CuO nanoparticles, Cu-based microtemperature sensors are formed. The sensors are thermistor-type ones whose temperature dependences of the resistance are used for measuring temperature inside the blood vessel model. This fabrication technique is useful for direct-writing of Cu-based microsensors and actuators on arbitrary nonplanar substrates.

  7. Validation of the performance of a practical blood vessel imaging system to facilitate vessel punctures

    Science.gov (United States)

    Cuper, Natascha J.; Verdaasdonk, Rudolf M.; de Roode, Rowland

    2009-02-01

    A practical system to visualize vessels underneath the skin has been developed, based on near-infrared (NIR) transillumination. A study in the clinical setting proved the system to be useful as a support in blood withdrawal in young children. During clinical application it was found that performance varied depending on vessel size, depth of vessels and surrounding lighting conditions. To gain more insight on the different variables that determine functioning of the system, we performed phantom studies. A combined liquid/solid phantom was fabricated with similar optical properties as the tissue layers of skin reported in literature at 850 nm. This phantom was used to estimate the depth of visibility in the relation to vessel size and darkness of the skin. Vessel contrast was determined analytically from images and evaluated by 3 independent observers. The knowledge gained from these experiments will be helpful to improve the imaging system and develop a solid phantom to be used as a gold standard to test the system under various clinical lighting conditions. The working range of the system was found to be appropriate to visualize the vessels used for the most procedures, such as blood withdrawal and placement of intravenous lines.

  8. Metallography and microstructure interpretation of some archaeological tin bronze vessels from Iran

    Energy Technology Data Exchange (ETDEWEB)

    Oudbashi, Omid, E-mail: o.oudbashi@aui.ac.ir [Department of Conservation of Historic Properties, Faculty of Conservation, Art University of Isfahan, Hakim Nezami Street, Sangtarashha Alley, P.O. Box 1744, Isfahan (Iran, Islamic Republic of); Davami, Parviz, E-mail: pdavami@razi-foundation.com [Faculty of Material Science and Engineering, Sharif University of Technology/Razi Applied Science Foundation, No. 27, Fernan St., Shahid Ghasem Asghari Blvd., km 21 of Karadj Makhsous Road, Tehran (Iran, Islamic Republic of)

    2014-11-15

    Archaeological excavations in western Iran have recently revealed a significant Luristan Bronzes collection from Sangtarashan archaeological site. The site and its bronze collection are dated to Iron Age II/III of western Iran (10th–7th century BC) according to archaeological research. Alloy composition, microstructure and manufacturing technique of some sheet metal vessels are determined to reveal metallurgical processes in western Iran in the first millennium BC. Experimental analyses were carried out using Scanning Electron Microscopy–Energy Dispersive X-ray Spectroscopy and Optical Microscopy/Metallography methods. The results allowed reconstructing the manufacturing process of bronze vessels in Luristan. It proved that the samples have been manufactured with a binary copper–tin alloy with a variable tin content that may relates to the application of an uncontrolled procedure to make bronze alloy (e.g. co-smelting or cementation). The presence of elongated copper sulphide inclusions showed probable use of copper sulphide ores for metal production and smelting. Based on metallographic studies, a cycle of cold working and annealing was used to shape the bronze vessels. - Highlights: • Sangtarashan vessels are made by variable Cu-Sn alloys with some impurities. • Various compositions occurred due to applying uncontrolled smelting methods. • The microstructure represents thermo-mechanical process to shape bronze vessels. • In one case, the annealing didn’t remove the eutectoid remaining from casting. • The characteristics of the bronzes are similar to other Iron Age Luristan Bronzes.

  9. Continuous Cooling Transformations in Nuclear Pressure Vessel Steels

    Science.gov (United States)

    Pous-Romero, Hector; Bhadeshia, Harry K. D. H.

    2014-10-01

    A class of low-alloy steels often referred to as SA508 represent key materials for the manufacture of nuclear reactor pressure vessels. The alloys have good properties, but the scatter in properties is of prime interest in safe design. Such scatter can arise from microstructural variations but most studies conclude that large components made from such steels are, following heat treatment, fully bainitic. In the present work, we demonstrate with the help of a variety of experimental techniques that the microstructures of three SA508 Gr.3 alloys are far from homogeneous when considered in the context of the cooling rates encountered in practice. In particular, allotriomorphic ferrite that is expected to lead to a deterioration in toughness, is found in the microstructure for realistic combinations of austenite grain size and the cooling rate combination. Parameters are established to identify the domains in which SA508 Gr.3 steels transform only into the fine bainitic microstructures.

  10. Triple-Vessel Percutaneous Coronary Revascularization In Situs Inversus Dextrocardia

    Directory of Open Access Journals (Sweden)

    Nikolaos Kakouros

    2010-01-01

    Full Text Available Dextrocardia with situs inversus occurs in approximately one in 10,000 individuals of whom 20% have primary ciliary dyskinesia inherited as an autosomal recessive trait. These patients have a high incidence of congenital cardiac disease but their risk of coronary artery disease is similar to that of the general population. We report what is, to our knowledge, the first case of total triple-vessel coronary revascularization by percutaneous stent implantation in a 79-year-old woman with situs inversus dextrocardia. We describe the successful use of standard diagnostic and interventional guide catheters with counter rotation and transversely inversed image acquisition techniques. The case also highlights that the right precordial pain may represent cardiac ischemia in this population.

  11. Hawaii Abandoned Vessel Inventory, French Frigate Shoals, NWHI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for French Frigate Shoals. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of...

  12. Hawaii Abandoned Vessel Inventory, Pearl & Hermes Atoll, NWHI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for , Pearl & Hermes, Atoll, NWHI. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical...

  13. 49 CFR 176.5 - Application to vessels.

    Science.gov (United States)

    2010-10-01

    ... (explosive) materials, Class 3 (flammable liquids), or Division 2.1 (flammable gas) materials, in which case... extinguish fire as the Coast Guard may prescribe; (7) A cable vessel, dredge, elevator vessel, fireboat...

  14. Drug Beats Steroids for Controlling Blood Vessel Inflammation in Study

    Science.gov (United States)

    ... html Drug Beats Steroids for Controlling Blood Vessel Inflammation in Study With tocilizumab's approval, there's an alternative ... treating the most common form of blood vessel inflammation known as giant cell arteritis, a new study ...

  15. Great Lakes Research Vessel Operations 1958-2016

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Great Lakes Research Vessel Operations data release is taken from the Research Vessel Catch (RVCAT) database curated at the Great Lakes Science Center (GLSC)....

  16. 19 CFR 4.60 - Vessels required to clear.

    Science.gov (United States)

    2010-04-01

    ... contiguous country otherwise than by sea. (c) Vessels which will merely transit the Panama Canal without... of clearance and related papers shall be surrendered. (e) No vessel shall be cleared for the high...

  17. Great Lakes Research Vessel Operations 1958-2016: OP

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — These data have been collected on various vessel operations on the Great Lakes and select connecting waterways. This vessel operations data set is part of and...

  18. Liver vessel segmentation based on extreme learning machine.

    Science.gov (United States)

    Zeng, Ye Zhan; Zhao, Yu Qian; Liao, Miao; Zou, Bei Ji; Wang, Xiao Fang; Wang, Wei

    2016-05-01

    Liver-vessel segmentation plays an important role in vessel structure analysis for liver surgical planning. This paper presents a liver-vessel segmentation method based on extreme learning machine (ELM). Firstly, an anisotropic filter is used to remove noise while preserving vessel boundaries from the original computer tomography (CT) images. Then, based on the knowledge of prior shapes and geometrical structures, three classical vessel filters including Sato, Frangi and offset medialness filters together with the strain energy filter are used to extract vessel structure features. Finally, the ELM is applied to segment liver vessels from background voxels. Experimental results show that the proposed method can effectively segment liver vessels from abdominal CT images, and achieves good accuracy, sensitivity and specificity. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Genetics of hereditary large vessel diseases.

    Science.gov (United States)

    Morisaki, Takayuki; Morisaki, Hiroko

    2016-01-01

    Recent progress in the study of hereditary large vessel diseases such as Marfan syndrome (MFS) have not only identified responsible genes but also provided better understanding of the pathophysiology and revealed possible new therapeutic targets. Genes identified for these diseases include FBN1, TGFBR1, TGFBR2, SMAD3, TGFB2, TGFB3, SKI, EFEMP2, COL3A1, FLNA, ACTA2, MYH11, MYLK and SLC2A10, as well as others. Their dysfunction disrupts the function of transforming growth factor-β (TGF-β) signaling pathways, as well as that of the extracellular matrix and smooth muscle contractile apparatus, resulting in progression of structural damage to large vessels, including aortic aneurysms and dissections. Notably, it has been shown that the TGF-β signaling pathway has a key role in the pathogenesis of MFS and related disorders, which may be important for development of strategies for medical and surgical treatment of thoracic aortic aneurysms and dissections.

  20. Immersive volume rendering of blood vessels

    Science.gov (United States)

    Long, Gregory; Kim, Han Suk; Marsden, Alison; Bazilevs, Yuri; Schulze, Jürgen P.

    2012-03-01

    In this paper, we present a novel method of visualizing flow in blood vessels. Our approach reads unstructured tetrahedral data, resamples it, and uses slice based 3D texture volume rendering. Due to the sparse structure of blood vessels, we utilize an octree to efficiently store the resampled data by discarding empty regions of the volume. We use animation to convey time series data, wireframe surface to give structure, and utilize the StarCAVE, a 3D virtual reality environment, to add a fully immersive element to the visualization. Our tool has great value in interdisciplinary work, helping scientists collaborate with clinicians, by improving the understanding of blood flow simulations. Full immersion in the flow field allows for a more intuitive understanding of the flow phenomena, and can be a great help to medical experts for treatment planning.

  1. Investigation of impulsively loaded pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Brown, N.; Cornwell, R.; Hanner, D.; Leichter, H.; Mohr, P.

    1963-10-15

    Explosion containment vessels for containing from 2,000 to 3,000 five ton nuclear explosions are considered. Analysis methods appear adequate and lowest weights using the most advanced materials available in the next five years are projected.None of these materials can be fabricated today and all require extensive development. Present material technology limits the choice of materials and defines the weight. The addition of safety factors and fixtures (nozzles, etc.) will add to this weight considerably, and may well radically alter the vessel response. Improvements in the strength weight ratios of metals and glasses over those considered in this report do not appear reasonable at this time. Winding schemes to utilize the high strength of steel wires and somehow maintain a reasonable thickness appear to offer the most promise. A `ductile` beryllium would of course offer vast improvement, but no indications that this is being developed have appeared and all presently known beryllium is much too brittle.

  2. Vessel-guided airway tree segmentation

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau; Sporring, Jon; Ashraf, Haseem

    2010-01-01

    method is evaluated on 250 low dose computed tomography images from a lung cancer screening trial. Our experiments showed that applying the region growing algorithm on the airway appearance model produces more complete airway segmentations, leading to on average 20% longer trees, and 50% less leakage......This paper presents a method for airway tree segmentation that uses a combination of a trained airway appearance model, vessel and airway orientation information, and region growing. We propose a voxel classification approach for the appearance model, which uses a classifier that is trained...... to differentiate between airway and non-airway voxels. This is in contrast to previous works that use either intensity alone or hand crafted models of airway appearance. We show that the appearance model can be trained with a set of easily acquired, incomplete, airway tree segmentations. A vessel orientation...

  3. TMI-2 reactor vessel head removal

    Energy Technology Data Exchange (ETDEWEB)

    Bengel, P.R.; Smith, M.D.; Estabrook, G.A.

    1985-09-01

    This report describes the safe removal and storage of the Three Mile Island Unit 2 (TMI-2) reactor vessel head. The head was removed in July 1984 to permit the removal of the plenum and the reactor core, which were damaged during the 1979 accident. From July 1982, plans and preparations were made using a standard head removal procedure modified by the necessary precautions and changes to account for conditions caused by the accident. After data acquisition, equipment and structure modifications, and training, the head was safely removed and stored; and the internals indexing fixture and a work platform were installed on top of the vessel. Dose rates during and after the operation were lower than expected; lessons were learned from the operation which will be applied to the continuing fuel removal operations activities.

  4. TMI-2 reactor vessel head removal

    Energy Technology Data Exchange (ETDEWEB)

    Bengel, P.R.; Smith, M.D.; Estabrook, G.A.

    1984-12-01

    This report describes the safe removal and storage of the Three Mile Island Unit 2 reactor vessel head. The head was removed in July 1984 to permit the removal of the plenum and the reactor core, which were damaged during the 1979 accident. From July 1982, plans and preparations were made using a standard head removal procedure modified by the necessary precautions and changes to account for conditions caused by the accident. After data acquisition, equipment and structure modifications, and training the head was safely removed and stored and the internals indexing fixture and a work platform were installed on top of the vessel. Dose rates during and after the operation were lower than expected; lessons were learned from the operation which will be applied to the continuing fuel removal operations activities.

  5. Wave intensity analysis in air-filled flexible vessels.

    Science.gov (United States)

    Clavica, Francesco; Parker, Kim H; Khir, Ashraf W

    2015-02-26

    Wave intensity analysis (WIA) is an analytical technique generally used to investigate the propagation of waves in the cardiovascular system. Despite its increasing usage in the cardiovascular system, to our knowledge WIA has never been applied to the respiratory system. Given the analogies between arteries and airways (i.e. fluid flow in flexible vessels), the aim of this work is to test the applicability of WIA with gas flow instead of liquid flow. The models employed in this study are similar to earlier studies used for arterial investigations. Simultaneous pressure (P) and velocity (U) measurements were initially made in a single tube and then in several flexible tubes connected in series. Wave speed was calculated using the foot-to-foot method (cf), which was used to separate analytically the measured P and U waveforms into their forward and backward components. Further, the data were used to calculate wave intensity, which was also separated into its forward and backward components. Although the measured wave speed was relatively high, the results showed that the onsets and the nature of reflections (compression/expansion) derived with WIA, corresponded well to those anticipated using the theory of waves in liquid-filled elastic tubes. On average the difference between the experimental and theoretical arrival time of reflection was 6.1% and 3.6% for the single vessel and multivessel experiment, respectively. The results suggest that WIA can provide relatively accurate information on reflections in air-filled flexible tubes, warranting further studies to explore the full potential of this technique in the respiratory system. Copyright © 2015. Published by Elsevier Ltd.

  6. Interplay between Inflammatory Responses and Lymphatic Vessels

    OpenAIRE

    Shin, Kihyuk; Lee, Seung-Hyo

    2014-01-01

    Lymphatic vessels are routes for leukocyte migration and fluid drainage. In addition to their passive roles in migration of leukocytes, increasing evidence indicates their active roles in immune regulation. Tissue inflammation rapidly induces lymphatic endothelial cell proliferation and chemokine production, thereby resulting in lymphangiogenesis. Furthermore, lymphatic endothelial cells induce T cell tolerance through various mechanisms. In this review, we focus on the current knowledge on h...

  7. Multiscale Vessel-guided Airway Tree Segmentation

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau; Sporring, Jon; de Bruijne, Marleen

    2009-01-01

    This paper presents a method for airway tree segmentation that uses a combination of a trained airway appearance model, vessel and airway orientation information, and region growing. The method uses a voxel classification based appearance model, which involves the use of a classifier...... is evaluated within EXACT’09 on a diverse set of CT scans. Results show a favorable combination of a relatively large portion of the tree detected correctly with very few false positives....

  8. LQG Dynamic Positioning for a Supply Vessel

    Science.gov (United States)

    Hansen, Scott Ron

    The purpose of this study is to merge my on the job marine experience and the control knowledge gathered throughout my studies at University of California San Diego into a practical control design. This thesis creates a Dynamic Positioning (DP) control loop for a supply vessel which utilizes two azimuthal thrusters as actuators. The control loop is designed to also account for external environmental disturbances and sensor measurement noise. The control loop is accomplished using modern control theory which makes use of known vessel dynamics and assumptions associated with the environment and sensor measurement variances. During this thesis research and design period, a testing platform for the control loop was required. Without the ability to retrofit a physical vessel with the proposed azimuthal thrusters it was determined that a simulation model would be required and was designed and implemented in Matlab Simulink to allow for control loop testing and validation. This simulation model is presented as part of the thesis research and design flow as it was a required element of the design and encompasses the knowledge acquired in my marine work and during my period at UCSD. Control loop performance results were obtained through testing on the generated simulation model. These results allowed for validation and optimization during the design phases of the vessel control loop. The principal conclusions were that the simulation model provided sufficient dynamics to properly execute the required tests to the control loop and that the implemented control loop was capable of operating within the determined parameters set forth in the design validation testing.

  9. ITER Vacuum Vessel design and construction

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, K., E-mail: Kimihiro.Ioki@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Choi, C.H.; Daly, E.; Dani, S.; Davis, J.; Giraud, B.; Gribov, Y.; Hamlyn-Harris, C. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Jones, L. [F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain); Jun, C. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Kim, B.C. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Kuzmin, E. [NTC ' Sintez' , Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Le Barbier, R.; Martinez, J.-M. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Pathak, H. [ITER-India, A-29, GIDC Electronic Estate, Sector -25, Gandhinagar 382025 (India); Preble, J.; Reich, J. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Sa, J.W. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Terasawa, A.; Utin, Yu. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); and others

    2012-08-15

    After implementing a few design modifications (referred to as the 'Modified Reference Design') in 2009, the Vacuum Vessel (VV) design had been stabilized. The VV design is being finalized, including interface components such as support rails and feedthroughs for the in-vessel coils. It is necessary to make adjustments to the locations of the blanket supports and manifolds to accommodate design modifications to the in-vessel coils. The VV support design is also being finalized considering a structural simplification. Design of the in-wall shielding (IWS) has progressed, considering the assembly methods and the required tolerances. The detailed layout of ferritic steel plates and borated steel plates was optimized based on the toroidal field ripple analysis. A dynamic test on the inter-modular key to support the blanket modules was performed to measure the dynamic amplification factor (DAF). An R and D program has started to select and qualify the welding and cutting processes for the port flange lip seal. The ITER VV material 316 L(N) IG was already qualified and the Modified Reference Design was approved by the Agreed Notified Body (ANB) in accordance with the Nuclear Pressure Equipment Order procedure.

  10. Nuclear reactor pressure vessel support system

    Science.gov (United States)

    Sepelak, George R.

    1978-01-01

    A support system for nuclear reactor pressure vessels which can withstand all possible combinations of stresses caused by a postulated core disrupting accident during reactor operation. The nuclear reactor pressure vessel is provided with a flange around the upper periphery thereof, and the flange includes an annular vertical extension formed integral therewith. A support ring is positioned atop of the support ledge and the flange vertical extension, and is bolted to both members. The plug riser is secured to the flange vertical extension and to the top of a radially outwardly extension of the rotatable plug. This system eliminates one joint through which fluids contained in the vessel could escape by making the fluid flow path through the joint between the flange and the support ring follow the same path through which fluid could escape through the plug risers. In this manner, the sealing means to prohibit the escape of contained fluids through the plug risers can also prohibit the escape of contained fluid through the securing joint.

  11. The oral mucosal surface and blood vessels.

    Science.gov (United States)

    Naumova, Ella A; Dierkes, Tobias; Sprang, Jürgen; Arnold, Wolfgang H

    2013-03-12

    Detailed information about the size of the oral mucosa is scarce in the literature, and those studies that do exist do not take into account the size of the tongue or the enlargement of the surface by the papillae. Because of the various functions of the oral mucosa in the maintenance of oral health, knowledge of its true size may provide a better understanding of the physiology of the oral cavity and some oral diseases and direct future therapeutic strategies. The aim of this study was to determine the total size of the oral mucosa. Five human adult cadaver heads were cut in the median sagittal plane, and the total area of the oral surface was determined using silicon casts. The surface of the tongue was measured with quantitative profilometry. Photographs of oral blood vessels were taken in different areas of the oral mucosa of adult test subjects using intravital microscopy, and the pictures were compared with vessel casts of the oral mucosal capillaries of a maccaca fasciculrais monkey, which was studied using a scanning electron microscope. The results showed that the dorsal side of the tongue comprises a large proportion of the total oral mucosal surface. The surface area of the epithelium increases moving from anterior to posterior on the tongue, and the number of underlying blood vessels increases proportionally. It can be concluded that the back of the tongue plays an important role in the oral resorption of drugs. The results may be of relevance for the delivery and development of oral drug application.

  12. 75 FR 74674 - Updates to Vessel Inspection Fees

    Science.gov (United States)

    2010-12-01

    .... commercial vessels required to maintain a Certificate of Inspection and foreign tankships and mobile offshore... owned ferries from payment of vessel inspection fees. The interim rule also revised the existing... covers U.S. vessel inspection fees plus other fees charged for foreign tankships and foreign mobile...

  13. 50 CFR 622.6 - Vessel and gear identification.

    Science.gov (United States)

    2010-10-01

    ... Section 622.6 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC... permanently affixed to or painted on the vessel in contrasting color to the background. (C) At least 18 inches... vessel or aircraft. (B) In the form of a circle permanently affixed to or painted on the vessel. (C) At...

  14. 46 CFR 308.2 - Requirements for eligible vessels.

    Science.gov (United States)

    2010-10-01

    ... the characteristics, employment, and general management of the vessel. The Maritime Administrator... breach of the warranty prescribed hereunder as to vessels in all categories with respect to Department of... warranties as to vessels in categories (b)(1) and (b)(2) of this section, with respect to maintenance of...

  15. 50 CFR 660.336 - Pacific whiting vessel licenses.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Pacific whiting vessel licenses. 660.336 Section 660.336 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND... Groundfish Fisheries § 660.336 Pacific whiting vessel licenses. (a) Pacific whiting vessel license—(1...

  16. 50 CFR 300.130 - Vessel and gear restrictions.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Vessel and gear restrictions. 300.130... gear restrictions. (a) Factory vessels. Factory vessels are prohibited from operating in treaty waters... top of the trap that, when removed, will leave an opening no smaller than the throat or entrance of...

  17. 46 CFR 308.1 - Eligibility for vessel insurance.

    Science.gov (United States)

    2010-10-01

    ... for sport fishing. (b) Any vessel, other than a vessel described in paragraph (a) of this section determined by the Maritime Administrator to be engaged in the national defense or the national economy of the... national defense or the national economy of the United States. Vessels in this category are not eligible...

  18. 46 CFR 42.13-10 - Freeboards assigned vessels.

    Science.gov (United States)

    2010-10-01

    ... with mechanical means of propulsion, or lighters, barges, or other vessels without independent means of... Commandant under the procedure of paragraph (f) of this section. (d) Vessels of wood or of composite construction, or of other materials the use of which the Commandant has approved, or vessels whose...

  19. 46 CFR 25.26-5 - Commercial fishing industry vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Commercial fishing industry vessels. 25.26-5 Section 25.26-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS Emergency Position Indicating Radio Beacons (EPIRB) § 25.26-5 Commercial fishing industry vessels. (a) The owner of a...

  20. 46 CFR 111.105-35 - Vessels carrying coal.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying coal. 111.105-35 Section 111.105-35...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-35 Vessels carrying coal. (a) The following are Class II, Division 1, (Zone 10 or Z) locations on a vessel that carries coal: (1) The interior of each coal...

  1. Vessel involvement in giant cell arteritis : an imaging approach

    NARCIS (Netherlands)

    Holm, Pieter W.; Sandovici, Maria; Slart, Riemer H. J. A.; Glaudemans, Andor W. J. M.; Rutgers, Abraham; Brouwer, Elisabeth

    Vasculitis is classified based on the size of the involved vessels. The two major forms are small vessel vasculitis and large vessel vasculitis (LVV). Main forms of LVV are Takayasu arteritis, giant cell arteritis (GCA), isolated aortitis and chronic periaortitis. This manuscript will focus on GCA,

  2. 46 CFR 90.10-16 - Industrial vessel.

    Science.gov (United States)

    2010-10-01

    ... PROVISIONS Definition of Terms Used in This Subchapter § 90.10-16 Industrial vessel. This term means every vessel which by reason of its special outfit, purpose, design, or function engages in certain industrial... 46 Shipping 4 2010-10-01 2010-10-01 false Industrial vessel. 90.10-16 Section 90.10-16 Shipping...

  3. Page 1 Multiferforate Plates in Xylem Vessels of Monocotyledonous ...

    Indian Academy of Sciences (India)

    Transverse section of a root of Alocasia indica showing 6 multiperforate plates in the vessel segments of the metaxylem. X46. FIG. 2.-A number of vessel segments from the root of Crinum asiaticum showing the two ends, x 15. FIG. 3.-Figure showing the arrangement of adjacent vessel segments with long oblique ends.

  4. 27 CFR 28.22 - Vessels employed in the fisheries.

    Science.gov (United States)

    2010-04-01

    ... fisheries. 28.22 Section 28.22 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... Lading for Use on Certain Vessels and Aircraft § 28.22 Vessels employed in the fisheries. Liquors may be... the fisheries, only for use on vessels of the United States documented to engage in the fisheries and...

  5. Coronary magnetic resonance angiography and vessel wall imaging in children with Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Greil, Gerald F.; Hofbeck, Michael; Sieverding, Ludger [University of Tuebingen, Department of Pediatric Cardiology, Children' s Hospital, Tuebingen (Germany); Seeger, Achim; Miller, Stephan; Claussen, Claus D. [University of Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Botnar, Rene M. [Technical University Munich, Department of Nuclear Medicine, Cardiovascular Division, Munich (Germany)

    2007-07-15

    In patients with Kawasaki disease (KD) serial evaluation of the distribution and size of coronary artery aneurysms (CAA) is necessary for risk stratification and therapeutic management. To apply whole-heart coronary MR angiography (CMRA) and black-blood coronary vessel wall imaging in children with KD. Six children (mean age 4.6 years, range 2.5-7.8 years) with KD underwent CMRA using a free-breathing, T2-prepared, three-dimensional steady-state free-precession (3D-SSFP), whole-heart approach with navigator gating and tracking. Vessel walls were imaged with an ECG-triggered and navigator-gated double inversion recovery (DIR) black-blood segmented turbo spin-echo sequence. There was complete agreement between CMRA and conventional angiography (n=6) in the detection of CAA (n=15). Excellent agreement was found between the two techniques in determining the maximal diameter (mean difference 0.2{+-}0.7 mm), length (mean difference 0.1{+-}0.8 mm) and distance from the ostium (mean difference -0.8{+-}2.1 mm) of the CAAs. In all subjects with a CAA, abnormally thickened vessel walls were found (2.5{+-}0.5 mm). CMRA accurately defines CAA in free-breathing sedated children with KD using the whole-heart approach and detects abnormally thickened vessel walls. This technique may reduce the need for serial X-ray coronary angiography, and improve risk stratification and monitoring of therapy. (orig.)

  6. [Morphogenesis, structure and properties of lymphatic vessels].

    Science.gov (United States)

    Ratajska, Anna; Jankowska-Steifer, Ewa; Czarnowska, Elżbieta; Flaht, Aleksandra; Radomska-Leśniewska, Dorota

    2012-11-19

    In this paper, we present literature results related to structure and various manners of lymphatic vessel formation during embryonic development and in pathological events, such as tumorigenesis, wound healing, and other diseases. The functions of the lymphatic system include the collection of fluids that enter tissues from the circulation, absorption of lipids and lipid-soluble vitamins from the intestine and their subsequent transport, participation in antigen, dendritic cell, and lymphocyte migration. The lymphatic system is also a route for tumor cell and inflammatory cell transport. Native lymphatic capillaries differ from blood capillaries by having an irregular lumen, a discontinuous basement membrane, absence of pericytes, and a strong anchorage of their endothelial cells to the extracellular matrix via microfibrils built of emilin and fibrillin. Lymphatic endothelial cells express surface antigens such as Lyve-1, podoplanin, VEGFR3 (Flk4) and transcription factor Prox-1, as well as molecules which are common for blood endothelial cells and lymphatic endothelial cells (CD31, CD34, Flk-1, Tie-1, Tie-2, neuropilin 2). Lymphatic vessel formation during embryonic development starts with the occurrence of lymphatic sacs sprouting from systemic jugular veins and/or by co-option of lymphangioblasts or hematopoietic-derived cells. It can also proceed by dedifferentiation of venous endothelial cells after their detachment from the venous system, migration to the target places within the body and assembly in the lymphatic lumen. Mechanisms of lymphatic vessel formation during embryonic development and in pathological conditions, such as tumorigenesis, wound healing, and metastasis, is regulated by a plethora of growth factors and molecules, among which the most important are VEGF-C, VEGF-D, HGF, FGF, retinoic acid, IL-3, and IL-7. Macrophages and cells bearing CD45 phenotype seem to take part in the formation of lymphatics. Macrophages might act as a source of growth

  7. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    Energy Technology Data Exchange (ETDEWEB)

    Heel, A.M.J.M. van

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP).

  8. 75 FR 39957 - Certificate of Alternative Compliance for the Offshore Supply Vessel/Well Stimulation Vessel BLUE...

    Science.gov (United States)

    2010-07-13

    ... Vessel BLUE TARPON AGENCY: Coast Guard, DHS. ACTION: Notice. SUMMARY: The Coast Guard announces that a Certificate of Alternative Compliance was issued for the offshore supply vessel BLUE TARPON as required by 33... Title 33, Code of Federal Regulation, Parts 81 and 89, has been issued for the offshore supply vessel...

  9. Model Of Navigational Safety Of Fishing Vessels In Polish EEZ

    Directory of Open Access Journals (Sweden)

    Przywarty Marcin

    2014-06-01

    Full Text Available The paper presents the assumptions of a simulation model for assessing the navigational safety of fishing vessels. The model consist of submodels of merchant and fishing vessels traffic, submodel of external condition and submodel of accident consequences. Paper present also a results of simulation experiment which was carried out for Polish EEZ. Model takes into account all Polish fishing vessels operating in the Polish EEZ with length more than 15 meters and the merchant vessels traffic in South Baltic Sea area. As a results positions of simulated collisions of fishing and merchant vessels, positions and sizes of simulated bunker spills and the positions of losses of fishing equipment were achieved.

  10. The passive biomechanics of human pelvic collecting lymphatic vessels.

    Science.gov (United States)

    Athanasiou, Dimitrios; Edgar, Lowell T; Jafarnejad, Mohammad; Nixon, Katherine; Duarte, Delfim; Hawkins, Edwin D; Jamalian, Samira; Cunnea, Paula; Lo Celso, Cristina; Kobayashi, Shunichi; Fotopoulou, Christina; Moore, James E

    2017-01-01

    The lymphatic system has a major significance in the metastatic pathways in women's cancers. Lymphatic pumping depends on both extrinsic and intrinsic mechanisms, and the mechanical behavior of lymphatic vessels regulates the function of the system. However, data on the mechanical properties and function of human lymphatics are lacking. Our aim is to characterize, for the first time, the passive biomechanical behavior of human collecting lymphatic vessels removed at pelvic lymph node dissection during primary debulking surgeries for epithelial ovarian cancer. Isolated vessels were cannulated and then pressurized at varying levels of applied axial stretch in a calcium-free Krebs buffer. Pressurized vessels were then imaged using multi-photon microscopy for collagen-elastin structural composition and fiber orientation. Both pressure-diameter and force-elongation responses were highly nonlinear, and axial stretching of the vessel served to decrease diameter at constant pressure. Pressure-diameter behavior for the human vessels is very similar to data from rat mesenteric vessels, though the human vessels were approximately 10× larger than those from rats. Multiphoton microscopy revealed the vessels to be composed of an inner layer of elastin with an outer layer of aligned collagen fibers. This is the first study that successfully described the passive biomechanical response and composition of human lymphatic vessels in patients with ovarian cancer. Future work should expand on this knowledge base with investigations of vessels from other anatomical locations, contractile behavior, and the implications on metastatic cell transport.

  11. Risk Assessment for Fishing Vessels at Fishing Grounds

    Directory of Open Access Journals (Sweden)

    Sergey Moyseenko

    2015-09-01

    Full Text Available Safety and efficiency of fishing fleet activity depend largely on the quality of management decisions. Cause-and-effect relationships of accidents involving fishing vessels were identified by means of an analysis of emergencies and fishing incidents. The suggested method of risks calculation is based on the use of statistical methods, fuzzy sets/expert estimations method and the probability theory. The following most common tasks are presented and solved: - there is an impact of two or more independent negative factors/events on the vessel such as failure of a sonar, a vessel operator error, another vessel operator error. - a transport vessel carries out loading and unloading of fishing vessels under different environmental conditions. The value of the risk of an emergency incident is determined. - the fishing vessel navigation performs under various meteorological conditions. A priori probability of incident-free operation is calculated according to expert estimations.

  12. Percutaneous Retrieval of Foreign Bodies Around Vital Vessels Aided with Vascular Intervention: A Technical Note

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiu-Jun, E-mail: woothingyang2008@126.com [Shanghai Eighth People’s Hospital, Department of Radiology (China); Xing, Guang-Fu, E-mail: xgf8848@126.com [Shanghai Eighth People’s Hospital, Department of General Surgery (China)

    2015-10-15

    ObjectiveTo describe a new interventional technique to remove foreign bodies (FBs) embedded in soft tissues around vital vessels.MethodsUnder fluoroscopic guidance and using local anesthesia, percutaneous removal of FBs was performed using forceps in nine patients. All patients suffered from a metallic soft tissue FB located in close proximity to important vessels and one also had a small traumatic pseudoaneurysm adjacent to the FB. Prior to removal of the FB, the position of the nearest vessel was identified using a guide wire or catheter placed into the vessel. Balloon catheter was also simultaneously used to temporarily stop the blood flow of the nearest artery during the FB removal in three of the nine patients.ResultsAll of the nine FBs with 0–2 mm interval to the nearest vessel were successfully removed in the nine patients without any serious complications. The removed FBs measured 3–12 mm in length and 1–3 mm in width. The total fluoroscopic time of retrieval of each FB was 5–9 min (mean, 6.4 min). The volume of intraoperative bleeding ranged from 5 to 12 ml (mean, 7.5 ml). The length of hospital stay for each patient ranged from 4 to 8 days (mean, 5.5 days).ConclusionVascular intervention-aided percutaneous FB removal is minimally invasive and an effective method for removal of FBs around vital vessels.

  13. Maritime Training Serbian Autonomous Vessel Protection Detachment

    Directory of Open Access Journals (Sweden)

    Šoškić Svetislav D.

    2014-06-01

    Full Text Available The crisis in Somalia has caused appearance of piracy at sea in the Gulf of Aden and the Western Indian Ocean. Somali pirates have become a threat to economic security of the world because almost 30 percent of world oil and 20 percent of global trade passes through the Gulf of Aden. Solving the problem of piracy in this part of the world have included international organizations, institutions, military alliances and the states, acting in accordance with international law and UN Security Council resolutions. The European Union will demonstrate the application of a comprehensive approach to solving the problem of piracy at sea and the crisis in Somalia conducting naval operation — EU NAVFOR Atalanta and operation EUTM under the Common Security and Defense Policy. The paper discusses approaches to solving the problem of piracy in the Gulf of Aden and the crisis in Somalia. Also, the paper points to the complexity of the crisis in Somalia and dilemmas correctness principles that are applied to solve the problem piracy at sea. One of goals is protections of vessels of the World Food Programme (WFP delivering food aid to displaced persons in Somalia. Republic of Serbia joined in this mission and trained and sent one a autonomous team in this military operation for protection WFP. This paper consist the problem of modern piracy, particularly in the area of the Horn of Africa became a real threat for the safety of maritime ships and educational process of Serbian Autonomous vessel protection detachment. Serbian Military Academy adopted and developed educational a training program against piracy applying all the provisions and recommendations of the IMO conventions and IMO model courses for Serbian Autonomous vessel protection detachment.

  14. Partial sternotomy coronary surgery with triple-vessel disease in dextrocardia and situs inversus totalis.

    Science.gov (United States)

    Su, Pi Xiong; Gu, Song; Liu, Yan; Gao, Jie

    2013-07-01

    Dextrocardia associated with situs inversus totalis is a rare congenital condition. A small number of cases with these conditions have been reported who underwent myocardial revascularization via the on-pump or off-pump techniques. Among them, only 1 patient with dextrocardia and situs inversus totalis was reported to have the procedure performed with minimally invasive coronary surgery via a right anterior small thoracotomy. However, the case was a single-vessel disease and only one graft was achieved. We describe the case of a 65-year old female patient with triple-vessel obstructive coronary diseases who was successfully revascularized with three grafts using a minimally invasive technique. This was achieved via partial sternotomy and employing off-pump coronary artery bypass grafting.

  15. Asymmetric dimethylarginine and coronary collateral vessel development.

    Science.gov (United States)

    Kocaman, Sinan Altan; Sahinarslan, Asife; Biberoglu, Gursel; Hasanoglu, Alev; Akyel, Ahmet; Timurkaynak, Timur; Cengel, Atiye

    2008-11-01

    Nitric oxide (NO) plays a major role in collateral vessel development. Asymmetric dimethylarginine (ADMA) that is an endogenous inhibitor of NO synthesis may impair the effective coronary collateral vessel development. The aim of this study was to evaluate the relationship between plasma ADMA level and coronary collateral vessel development. The patients with a greater than or equal to 95% obstruction in at least one epicardial coronary artery were included in the study. Degree of coronary collateral development was determined according to Rentrop method. Patients with grade 2-3 collateral development were regarded as good collateral group and formed group I. The patients with grade 0-1 collateral development were regarded as poor collateral group and were included in group II. Group III that had been formed as a control group included the patients with a normal coronary angiogram. We compared the plasma ADMA, symmetric dimethylarginine, L-arginine/ADMA ratio among three groups. Seventy-four patients have been included in the study. Patients with good collateral development had lower plasma ADMA level in comparison with patients with poor collateral development (0.41+/-0.25 micromol/l vs. 0.70+/-0.23 micromol/l, P=0.001) and had similar plasma ADMA levels with the patients who have normal coronary arteries. When we compared L-arginine/ADMA ratio between good and poor collateral groups, we found that the patients with higher L-arginine/ADMA ratio have significantly better collateral development (270.8+/-168.0 vs. 120.9+/-92.1, P<0.001). In the analyses comparing Rentrop score with ADMA level and L-arginine/ADMA ratio, there were significant correlations (r=-0.444, P=0.008 and r=0.553, P=0.001, respectively). In multivariate analysis, ADMA level (odds ratio, 0.009; 95% confidence interval, 0.000-0.466, P=0.020) and L-arginine/ADMA ratio (odds ratio, 1.010; 95% confidence interval, 1.001-1.020, P=0.032) were independent predictors of collateral development. Increased

  16. Kendall Analysis of Cannon Pressure Vessels

    Science.gov (United States)

    2012-04-11

    Comparisons”, Journal of Pressure Vessel Technology, Vol. 123, 271-281. [5] Underwood, J.H., deSwardt, R.R., Venter, A.M., Troiano , E., Hyland...Pressure and Fatigue Life,” ASME PVP Conference, San Antonio, TX, July 22-26, 2007. [6] J.H. Underwood, A.P. Parker, E. Troiano , 2006, “Effect of...Paris and G..R. Irwin, 1985, The Stress Analysis of Cracks Handbook, Paris Productions Inc., St. Louis, MO. [8] E. Troiano , A.P. Parker and J.H

  17. Reactor Pressure Vessel (RPV) Acquisition Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Mizia, Ronald Eugene [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2008-04-01

    The Department of Energy has selected the High Temperature Gas-cooled Reactor design for the Next Generation Nuclear Plant (NGNP) Project. The NGNP will demonstrate the use of nuclear power for electricity and hydrogen production. It will have an outlet gas temperature in the range of 900°C and a plant design service life of 60 years. The reactor design will be a graphite moderated, helium-cooled, prismatic or pebble-bed reactor and use low-enriched uranium, TRISO-coated fuel. The plant size, reactor thermal power, and core configuration will ensure passive decay heat removal without fuel damage or radioactive material releases during accidents. The NGNP Materials Research and Development (R&D) Program is responsible for performing R&D on likely NGNP materials in support of the NGNP design, licensing, and construction activities. Selection of the technology and design configuration for the NGNP must consider both the cost and risk profiles to ensure that the demonstration plant establishes a sound foundation for future commercial deployments. The NGNP challenge is to achieve a significant advancement in nuclear technology while at the same time setting the stage for an economically viable deployment of the new technology in the commercial sector soon after 2020. The purpose of this report is to address the acquisition strategy for the NGNP Reactor Pressure Vessel (RPV). This component will be larger than any nuclear reactor pressure vessel presently in service in the United States. The RPV will be taller, larger in diameter, thicker walled, heavier and most likely fabricated at the Idaho National Laboratory (INL) site of multiple subcomponent pieces. The pressure vessel steel can either be a conventional materials already used in the nuclear industry such as listed within ASME A508/A533 specifications or it will be fabricated from newer pressure vessel materials never before used for a nuclear reactor in the US. Each of these characteristics will present a

  18. Waterborne Transportation Lines of the United States : calendar year 2008. Volume 2 : vessel company summary

    Science.gov (United States)

    2009-11-16

    The Vessel Company Summary, Volume 2, : is one of three publications for the annual : revision of the WTLUS, which provides a summary : of the vessel companies detailed in the : WTLUS, Vessel Characteristics, Volume 3. : The names of the vessel compa...

  19. Qualification according to PDI's techniques UT EPRI methodology Phased Array for the inspection of vessels of PWR reactor with advanced robotic equipment; Cualificacion segun metodologia PDI de EPRI de te cnicas UT Phased Array para la inspeccion de vasijas de reactor PWR con eq uipos roboticos avanzados

    Energy Technology Data Exchange (ETDEWEB)

    Gadea, J. R.; Gonzalez, P.; Fernandez, F.

    2014-07-01

    The techniques and procedures qualified in the program EPRI PDI are directly applicable in plants whose reference code is ASME XI - specifically the Appendix VIII-, mainly USA and countries in which it is established American PWR technology. While countries with reactors in operation technology ABB (Sweden) or type VVER (Finland and Eastern countries) requires a qualification of specific technical type ENIQ, PDI qualification is a valuable reference since it allows to deal with such qualifications with guarantees. (Author)

  20. Inspection of dissimilar metal welds in reactor pressure vessels in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Gadea, J.R.; Regidor, J.J.; Pelaez, J.A.; Serrano, P. [Tecnatom, S.A., San Sebastian de los Reyes, Madrid (Spain)

    2011-07-01

    MRP-139 recommendations for inspection of dissimilar metal (DM) welds in PWR vessels were launched in the last years in the USA. Basically, it increases the frequency of the examinations in these type of welds, with major emphasis in the hot loops, adding one intermediate inspection at the ten years interval in outlet nozzles. The spanish nuclear power plants (NPP's) have begun the implementation of this type of inspections on the vessel nozzles DM welds. As this type of inspections could have an impact in the critical path duration of the outage, it is necessary the use of a mechanical equipment able to examine the nozzles DM welds in a short vessel occupation time (VOT) with high quality, qualified techniques and minimum requirements of the refuelling platform. Tecnatom undertook the design and development of a new more advanced equipment, named TENIS-DM, for implementing the reactor pressure vessel (RPV) nozzles examination. This equipment was designed in order to accomplish the stringent requirements and the updated examination techniques; it was used for the inspection of the DM welds of Asco 1 NPP inlet and outlet nozzles in March 2011. Examination techniques and procedures were qualified through the GRUVAL validation program, based on ENIC methodology. Mechanical scanner was equipped with a large number of examination probes, and TV cameras -for visual inspection and also for monitoring the ultrasonic inspections. A remote operated submarine was also used to give support to the operational personnel during the manipulation of the equipment and its movements from one nozzle to the others. During two months before the inspection, tests of the complete inspection system were made on a nozzle mock-up installed in a 4 meters deep well at Tecnatom's facilities; this scenario was also used during the training sessions of the inspection crew. The defined technical and practical objectives were achieved: use of qualified techniques and minimal impact on the

  1. A SURVEY OF RETINA BASED DISEASE IDENTIFICATION USING BLOOD VESSEL SEGMENTATION

    Directory of Open Access Journals (Sweden)

    P Kuppusamy

    2016-11-01

    Full Text Available The colour retinal photography is one of the most essential features to identify the confirmation of various eye diseases. The iris is primary attribute to authenticate the human. This research work presents the survey and comparison of various blood vessel related feature identification, segmentation, extraction and enhancement methods. Additionally, this study is observed the various databases performance for storing the images and testing in minimal time. This paper is also provides the better performance techniques based on the survey.

  2. Optic disc segmentation: level set methods and blood vessels inpainting

    Science.gov (United States)

    Almazroa, A.; Sun, Weiwei; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-03-01

    Segmenting the optic disc (OD) is an important and essential step in creating a frame of reference for diagnosing optic nerve head (ONH) pathology such as glaucoma. Therefore, a reliable OD segmentation technique is necessary for automatic screening of ONH abnormalities. The main contribution of this paper is in presenting a novel OD segmentation algorithm based on applying a level set method on a localized OD image. To prevent the blood vessels from interfering with the level set process, an inpainting technique is applied. The algorithm is evaluated using a new retinal fundus image dataset called RIGA (Retinal Images for Glaucoma Analysis). In the case of low quality images, a double level set is applied in which the first level set is considered to be a localization for the OD. Five hundred and fifty images are used to test the algorithm accuracy as well as its agreement with manual markings by six ophthalmologists. The accuracy of the algorithm in marking the optic disc area and centroid is 83.9%, and the best agreement is observed between the results of the algorithm and manual markings in 379 images.

  3. New technique for withdrawing broken sheath

    Directory of Open Access Journals (Sweden)

    Süleyman Cagan Efe

    2016-03-01

    Full Text Available A sheath that is broken inside vessel is a rare complication, and intravascular fragments from broken sheaths are retrieving transcutaneously by techniques including the loop snare catheter, basket catheter, and grasping/biopsy forceps. We reported a less common type of broken central venous sheath in location and a successful unique technique for retrieving it from subclavian vein by using noncompliant balloon from 40 year old female patient.

  4. Young capillary vessels rejuvenate aged pancreatic islets

    Science.gov (United States)

    Almaça, Joana; Molina, Judith; Arrojo e Drigo, Rafael; Abdulreda, Midhat H.; Jeon, Won Bae; Berggren, Per-Olof; Caicedo, Alejandro; Nam, Hong Gil

    2014-01-01

    Pancreatic islets secrete hormones that play a key role in regulating blood glucose levels (glycemia). Age-dependent impairment of islet function and concomitant dysregulation of glycemia are major health threats in aged populations. However, the major causes of the age-dependent decline of islet function are still disputed. Here we demonstrate that aging of pancreatic islets in mice and humans is notably associated with inflammation and fibrosis of islet blood vessels but does not affect glucose sensing and the insulin secretory capacity of islet beta cells. Accordingly, when transplanted into the anterior chamber of the eye of young mice with diabetes, islets from old mice are revascularized with healthy blood vessels, show strong islet cell proliferation, and fully restore control of glycemia. Our results indicate that beta cell function does not decline with age and suggest that islet function is threatened by an age-dependent impairment of islet vascular function. Strategies to mitigate age-dependent dysregulation in glycemia should therefore target systemic and/or local inflammation and fibrosis of the aged islet vasculature. PMID:25404292

  5. Analisa Greenwater Akibat Gerakan Offshore Security Vessel

    Directory of Open Access Journals (Sweden)

    Maulidya Octaviani Bustamin

    2012-09-01

    Full Text Available Analisa  Tugas  Akhir  ini,  terdiri  atas  beberapa  tahapan.  Yang pertama yaitu perancangan struktur Offshore Security Vessel (OSV dengan bantuan software MAXSURF guna mendapatkan Lines Plan. Offset data yang diperoleh digunakan dalam pemodelan menggunakan MOSES,  kemudian  dilakukan  analisa  gerak  OSV  dalam  gelombang  regular  dan dinyatakan dalam grafik RAO. Analisa gerak relatif vertikal  haluan dihitung dari RAO gerakan, dan kemudian melakukan evaluasi perilaku di gelombang acak dengan analisis spektra gelombang. Dari analisa spektra didapatkan parameter greenwater sehingga dapat dihitung peluang, intensitas dan tekanan greenwater. Dari hasil analisa diperoleh RAO gerak vertikal Offshore Security Vessel (OSV pada  gelombang  reguler yang dipengaruhi  oleh  kecepatan,  kondisi  muatan  dan arah gelombang. Peluang terjadinya greenwater terbesar terjadi pada sudut datang gelombang following sea (0o dimana harga terbesar terjadi pada ω = 0.2 rad/sec dengan periode 29 detik mencapai 0.477. Intensitas greenwater terbesar terjadi pada saat sudut datang gelombang following sea (0o adalah sebanyak 59.265 per jam dan 0.378 per detik. Tekanan greenwater terbesar terjadi pada saat sudut datang gelombang head sea (180o sebesar 1678x10-6 MPa. Dengan nilai tersebut, deck mampu menahan beban akibat tekanan greenwater.

  6. Structural integrity of nuclear reactor pressure vessels

    Science.gov (United States)

    Knott, John F.

    2013-09-01

    The paper starts from concerns expressed by Sir Alan Cottrell, in the early 1970s, related to the safety of the pressurized water reactor (PWR) proposed at that time for the next phase of electrical power generation. It proceeds to describe the design and operation of nuclear generation plant and gives details of the manufacture of PWR reactor pressure vessels (RPVs). Attention is paid to stress-relief cracking and under-clad cracking, experienced with early RPVs, explaining the mechanisms for these forms of cracking and the means taken to avoid them. Particular note is made of the contribution of non-destructive inspection to structural integrity. Factors affecting brittle fracture in RPV steels are described: in particular, effects of neutron irradiation. The use of fracture mechanics to assess defect tolerance is explained, together with the failure assessment diagram embodied in the R6 procedure. There is discussion of the Master Curve and how it incorporates effects of irradiation on fracture toughness. Dangers associated with extrapolation of data to low probabilities are illustrated. The treatment of fatigue-crack growth is described, in the context of transients that may be experienced in the operation of PWR plant. Detailed attention is paid to the thermal shock associated with a large loss-of-coolant accident. The final section reviews the arguments advanced to justify 'Incredibility of Failure' and how these are incorporated in assessments of the integrity of existing plant and proposed 'new build' PWR pressure vessels.

  7. Using Seasonal Forecasting Data for Vessel Routing

    Science.gov (United States)

    Bell, Ray; Kirtman, Ben

    2017-04-01

    We present an assessment of seasonal forecasting of surface wind speed, significant wave height and ocean surface current speed in the North Pacific for potential use of vessel routing from Singapore to San Diego. WaveWatchIII is forced with surface winds and ocean surface currents from the Community Climate System Model 4 (CCSM4) retrospective forecasts for the period of 1982-2015. Several lead time forecasts are used from zero months to six months resulting in 2,720 model years, ensuring the findings from this study are robust. July surface wind speed and significant wave height can be skillfully forecast with a one month lead time, with the western North Pacific being the most predictable region. Beyond May initial conditions (lead time of two months) the El Niño Southern Oscillation (ENSO) Spring predictability barrier limits skill of significant wave height but there is skill for surface wind speed with January initial conditions (lead time of six months). In a separate study of vessel routing between Norfolk, Virginia and Gibraltar we demonstrate the benefit of a multimodel approach using the North American Multimodel Ensemble (NMME). In collaboration with Charles River Analytics an all-encompassing forecast is presented by using machine learning on the various ensembles which can be using used for industry applications.

  8. Development and plasticity of meningeal lymphatic vessels.

    Science.gov (United States)

    Antila, Salli; Karaman, Sinem; Nurmi, Harri; Airavaara, Mikko; Voutilainen, Merja H; Mathivet, Thomas; Chilov, Dmitri; Li, Zhilin; Koppinen, Tapani; Park, Jun-Hee; Fang, Shentong; Aspelund, Aleksanteri; Saarma, Mart; Eichmann, Anne; Thomas, Jean-Léon; Alitalo, Kari

    2017-11-15

    The recent discovery of meningeal lymphatic vessels (LVs) has raised interest in their possible involvement in neuropathological processes, yet little is known about their development or maintenance. We show here that meningeal LVs develop postnatally, appearing first around the foramina in the basal parts of the skull and spinal canal, sprouting along the blood vessels and cranial and spinal nerves to various parts of the meninges surrounding the central nervous system (CNS). VEGF-C, expressed mainly in vascular smooth muscle cells, and VEGFR3 in lymphatic endothelial cells were essential for their development, whereas VEGF-D deletion had no effect. Surprisingly, in adult mice, the LVs showed regression after VEGF-C or VEGFR3 deletion, administration of the tyrosine kinase inhibitor sunitinib, or expression of VEGF-C/D trap, which also compromised the lymphatic drainage function. Conversely, an excess of VEGF-C induced meningeal lymphangiogenesis. The plasticity and regenerative potential of meningeal LVs should allow manipulation of cerebrospinal fluid drainage and neuropathological processes in the CNS. © 2017 Antila et al.

  9. 77 FR 55439 - Vessel Traffic Service Updates, Including Establishment of Vessel Traffic Service Requirements...

    Science.gov (United States)

    2012-09-10

    ... SOLAS Convention since 2004. Because AIS carriage is required by regulation under 33 CFR 164.46 for... Waterway Safety Assessment PAWSS Port and Waterways Safety System PWSA Ports and Waterways Safety Act SOLAS International Convention for the Safety of Life at Sea U.S.C. United States Code VTM Vessel Traffic Management...

  10. Modeling the microclimate inside a vessel in in vitro culture : vessel ...

    African Journals Online (AJOL)

    M

    Numerical simulations show that variations in vessel internal humidity was ... Keywords : Agar, in vitro culture, microclimate, modeling, transfer coefficient. ... determining the atmospheric conditions inside .... is a function of air speed was used. .... latent heat of evaporation, R the gas constant and .... mesoscale circulation.

  11. 78 FR 51664 - Vessel Traffic Service Updates, Including Establishment of Vessel Traffic Service Requirements...

    Science.gov (United States)

    2013-08-21

    ... pool gauge is at approximately 13.0 feet or above. Lower Mississippi River--0036699952: New Orleans... of Vessel Traffic Service Requirements for Port Arthur, Texas and Expansion of VTS Special Operating... for Port Arthur, Texas and Expansion of VTS Special Operating Area in Puget Sound'' (77 FR 55439). The...

  12. Cognitive profiles in degenerative dementia without evidence of small vessel pathology and small vessel vascular dementia.

    Science.gov (United States)

    De Carolis, Antonella; Cipollini, Virginia; Donato, Nicole; Sepe-Monti, Micaela; Orzi, Francesco; Giubilei, Franco

    2017-01-01

    Although a large number of studies have examined possible differences in cognitive performance between Alzheimer's disease (AD) and vascular dementia (VaD), the data in the literature are conflicting. The aims of this study were to analyze the neuropsychological pattern of subjects affected by degenerative dementia without evidence of small vessel pathology (DD) and small vessel VaD subjects in the early stages and to investigate differences in the progression of cognitive impairment. Seventy-five patients with probable VaD and 75 patients with probable DD were included. All the subjects underwent a standard neuropsychological evaluation, including the following test: Visual Search, Attentional matrices, Story Recall, Raven's Coloured Progressive Matrices, Phonological and Semantic Verbal Fluency, Token, and Copying Drawings. The severity of cognitive impairment was stratified according to the MMSE score. Fifteen subjects with probable DD and 10 subjects with probable VaD underwent a 12-month cognitive re-evaluation. No significant difference was found between DD and VaD subjects in any of the neuropsychological tests except Story Recall in the mild cognitive impairment (P dementia without evidence of small vessel pathology from small vessel VaD in the early stages of these diseases.

  13. 50 CFR 300.116 - Requirements for a vessel monitoring system for U.S. vessels.

    Science.gov (United States)

    2010-10-01

    ... procedures indicated on an installation and activation checklist, which is available from OLE; and (2) Submit to OLE a statement certifying compliance with the checklist, as prescribed on the checklist. (c... instructions from that office. If notified by NMFS that a vessel's VMS is not operating properly, the owner and...

  14. 46 CFR 380.11 - Designation of American Great Lakes Vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Designation of American Great Lakes Vessels. 380.11... Application for Designation of Vessels as American Great Lakes Vessels § 380.11 Designation of American Great Lakes Vessels. The Secretary shall designate a vessel as an American Great Lakes vessel if— (a) The...

  15. 46 CFR 69.7 - Vessels transiting the Panama and Suez Canals.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Vessels transiting the Panama and Suez Canals. 69.7... MEASUREMENT OF VESSELS MEASUREMENT OF VESSELS General § 69.7 Vessels transiting the Panama and Suez Canals. (a) All vessels intending to transit the Panama Canal, other than vessels of war, must be measured and...

  16. 77 FR 74777 - Safety Zones; Grain-Shipment Assistance Vessels; Columbia and Willamette Rivers

    Science.gov (United States)

    2012-12-18

    ... Foss, IMO 7638454, the motor vessel Washington, IMO 8207733, the motor vessel George W, IMO 9153329... 7638454, the motor vessel Washington, IMO 8207733, the motor vessel George W, IMO 9153329, and the motor... of the motor vessel George W, IMO 9153329, and 50 yards abeam and astern of this vessel while it is...

  17. Standard practice for examination of seamless, gas-filled, steel pressure vessels using angle beam ultrasonics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice describes a contact angle-beam shear wave ultrasonic technique to detect and locate the circumferential position of longitudinally oriented discontinuities and to compare the amplitude of the indication from such discontinuities to that of a specified reference notch. This practice does not address examination of the vessel ends. The basic principles of contact angle-beam examination can be found in Practice E 587. Application to pipe and tubing, including the use of notches for standardization, is described in Practice E 213. 1.2 This practice is appropriate for the ultrasonic examination of cylindrical sections of gas-filled, seamless, steel pressure vessels such as those used for the storage and transportation of pressurized gasses. It is applicable to both isolated vessels and those in assemblies. 1.3 The practice is intended to be used following an Acoustic Emission (AE) examination of stacked seamless gaseous pressure vessels (with limited surface scanning area) described in Test Met...

  18. UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences

    Science.gov (United States)

    2015-01-01

    Purpose: The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US) for evaluating hepatic vessels in liver recipients. Methods: Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. Results: The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924). The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251±99 seconds) and conventional (231±117 seconds) Doppler studies (P=0.306). In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272±157 seconds) required a shorter time than conventional Doppler US (381±133 seconds; P=0.005). There was no difference between the two techniques with respect to technical failures and clinical decisions. Conclusion: UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up. PMID:25409662

  19. VESSEL CENTERLINE TRACKING AND BOUNDARY SEGMENTATION IN CORONARY MRA WITH MINIMAL MANUAL INTERACTION.

    Science.gov (United States)

    Soleimanifard, Sahar; Schär, Michael; Hays, Allison G; Weiss, Robert G; Stuber, Matthias; Prince, Jerry L

    2012-01-01

    Magnetic resonance angiography (MRA) provides a noninvasive means to detect the presence, location and severity of atherosclerosis throughout the vascular system. In such studies, and especially those in the coronary arteries, the vessel luminal area is typically measured at multiple cross-sectional locations along the course of the artery. The advent of fast volumetric imaging techniques covering proximal to mid segments of coronary arteries necessitates automatic analysis tools requiring minimal manual interactions to robustly measure cross-sectional area along the three-dimensional track of the arteries in under-sampled and non-isotropic datasets. In this work, we present a modular approach based on level set methods to track the vessel centerline, segment the vessel boundaries, and measure transversal area using two user-selected endpoints in each coronary of interest. Arterial area and vessel length are measured using our method and compared to the standard Soap-Bubble reformatting and analysis tool in in-vivo non-contrast enhanced coronary MRA images.

  20. Vessel packaging effect in laser speckle contrast imaging and laser Doppler imaging

    Science.gov (United States)

    Fredriksson, Ingemar; Larsson, Marcus

    2017-10-01

    Laser speckle-based techniques are frequently used to assess microcirculatory blood flow. Perfusion estimates are calculated either by analyzing the speckle fluctuations over time as in laser Doppler flowmetry (LDF), or by analyzing the speckle contrast as in laser speckle contrast imaging (LSCI). The perfusion estimates depend on the amount of blood and its speed distribution. However, the perfusion estimates are commonly given in arbitrary units as they are nonlinear and depend on the magnitude and the spatial distribution of the optical properties in the tissue under investigation. We describe how the spatial confinement of blood to vessels, called the vessel packaging effect, can be modeled in LDF and LSCI, which affect the Doppler power spectra and speckle contrast, and the underlying bio-optical mechanisms for these effects. As an example, the perfusion estimate is reduced by 25% for LDF and often more than 50% for LSCI when blood is located in vessels with an average diameter of 40 μm, instead of being homogeneously distributed within the tissue. This significant effect can be compensated for only with knowledge of the average diameter of the vessels in the tissue.

  1. UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences

    Energy Technology Data Exchange (ETDEWEB)

    Hur, Bo Yun; Lee, Jae Young; Chu, A Jung; Kim, Se Hyung; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-01-15

    The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US) for evaluating hepatic vessels in liver recipients. Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924). The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251±99 seconds) and conventional (231±117 seconds) Doppler studies (P=0.306). In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272±157 seconds) required a shorter time than conventional Doppler US (381±133 seconds; P=0.005). There was no difference between the two techniques with respect to technical failures and clinical decisions. UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up.

  2. UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences

    Directory of Open Access Journals (Sweden)

    Bo Yun Hur

    2015-01-01

    Full Text Available Purpose: The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US for evaluating hepatic vessels in liver recipients. Methods: Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. Results: The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924. The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251±99 seconds and conventional (231±117 seconds Doppler studies (P=0.306. In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272±157 seconds required a shorter time than conventional Doppler US (381±133 seconds; P=0.005. There was no difference between the two techniques with respect to technical failures and clinical decisions. Conclusion: UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up.

  3. Computational Fluid Dynamics Analysis of Pulsatile Blood Flow Behavior in Modelled Stenosed Vessels with Different Severities

    Directory of Open Access Journals (Sweden)

    Mohsen Mehrabi

    2012-01-01

    Full Text Available This study focuses on the behavior of blood flow in the stenosed vessels. Blood is modelled as an incompressible non-Newtonian fluid which is based on the power law viscosity model. A numerical technique based on the finite difference method is developed to simulate the blood flow taking into account the transient periodic behaviour of the blood flow in cardiac cycles. Also, pulsatile blood flow in the stenosed vessel is based on the Womersley model, and fluid flow in the lumen region is governed by the continuity equation and the Navier-Stokes equations. In this study, the stenosis shape is cosine by using Tu and Devil model. Comparing the results obtained from three stenosed vessels with 30%, 50%, and 75% area severity, we find that higher percent-area severity of stenosis leads to higher extrapressure jumps and higher blood speeds around the stenosis site. Also, we observe that the size of the stenosis in stenosed vessels does influence the blood flow. A little change on the cross-sectional value makes vast change on the blood flow rate. This simulation helps the people working in the field of physiological fluid dynamics as well as the medical practitioners.

  4. Improved vessel painting with carbocyanine dye-liposome solution for visualisation of vasculature.

    Science.gov (United States)

    Konno, Alu; Matsumoto, Naoya; Okazaki, Shigetoshi

    2017-08-30

    Vessel painting is one of the most accessible and cost-effective techniques for visualising vasculature by fluorescence microscopy. In this method, the hydrophobic carbocyanine dye DiIC18 labels the plasma membrane via insertion of its alkyl chains into the lipid bilayer. A major disadvantage of this procedure is that it does not stain veins and some microvessels in mouse brain. Furthermore, DiIC18 molecules can aggregate during perfusion, thereby occluding arteries and reducing the success rate and reproducibility of the experiment. To overcome these problems, we developed an improved vessel painting procedure that employs neutral liposomes (NLs) and DiIC12. NLs prevented DiI aggregation under physiological conditions whereas DiIC12 showed enhanced dye incorporation into liposomes and consequently increased staining intensity. Using this method, we successfully labelled all major blood vessel types in the mouse brain, including both veins and microvessels. Thus, liposome-mediated vessel painting is a simple and efficient method for visualising vasculature.

  5. Vessel Sampling and Blood Flow Velocity Distribution With Vessel Diameter for Characterizing the Human Bulbar Conjunctival Microvasculature.

    Science.gov (United States)

    Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua

    2016-03-01

    This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, P<0.05). This was the first study to determine the sampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.

  6. Distribution of the In-Vessel Diagnostics in ITER Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    González, Jorge, E-mail: Jorge.Gonzalez@iter.org [Rüecker Lypsa, Carretera del Prat, 65, Cornellá de Llobregat (Spain); Clough, Matthew; Martin, Alex; Woods, Nick; Suarez, Alejandro [ITER Organization, Route de Vinon sur Verdon-CS 90 046 13067 Saint Paul Lez Durance (France); Martinez, Gonzalo [Technical University Of Catalonia (UPC), Barcelona-Tech, Barcelona (Spain); Stefan, Gicquel; Yunxing, Ma [ITER Organization, Route de Vinon sur Verdon-CS 90 046 13067 Saint Paul Lez Durance (France)

    2017-01-15

    The ITER In-Vessel Diagnostics have been distributed around the In-Vessel shell to understand burning plasma physics and assist in machine operation. Each diagnostics component has its own requirements, constraints, and even exclusion among them for the highly complex In-Vessel environment. The size of the plasma, the requirement to be able to align the blanket system to the magnetic centre of the machine, the cooling requirements of the blanket system and the size of the pressure vessel itself all add to the difficulties of integrating these systems into the remaining space available. The available space for the cables inside the special trays (in-Vessel looms) is another constraint to allocate In-Vessel electrical sensors. Besides this, there are issues with the Assembly sequences and surface & volumetric neutron heating considerations that have imposed several additional restrictions.

  7. Bone marrow blood vessels: normal and neoplastic niche

    Directory of Open Access Journals (Sweden)

    Saeid Shahrabi

    2016-11-01

    Full Text Available Blood vessels are among the most important factors in the transport of materials such as nutrients and oxygen. This study will review the role of blood vessels in normal bone marrow hematopoiesis as well as pathological conditions like leukemia and metastasis. Relevant literature was identified by a Pubmed search (1992-2016 of English-language papers using the terms bone marrow, leukemia, metastasis, and vessel. Given that blood vessels are conduits for the transfer of nutrients, they create a favorable situation for cancer cells and cause their growth and development. On the other hand, blood vessels protect leukemia cells against chemotherapy drugs. Finally, it may be concluded that the vessels are an important factor in the development of malignant diseases.

  8. [Addiction among patients hospitalized due to peripheral vessels disorders].

    Science.gov (United States)

    Wójcik, Alicja; Sodolski, Wojciech; Jaworska, Elzbieta; Borzecki, Andrzej; Brzeski, Zdzisław

    2005-01-01

    The study covered 160 patients - 80 females and 80 males, hospitalised due to arterial and venous vessels disorders. The objective of the study was an attempt to evaluate selected behaviours, such as tobacco smoking, consumption of alcohol and coffee among people with diseases of peripheral vessels. The research tool was a questionnaire form. Participation in the study was voluntary and patients were selected at random. The study showed that 60% of respondents suffered from peripheral vessels disorders, 67.5% of females had venous vessels disorders, and 87.5% of males - arterial vessels disorders. In the total population examined 69.38% of respondents consumed alcohol, 47.5% were current smokers, and 56.88% consumed coffee. The style of life of the people examined may result in the development of peripheral vessel disorders.

  9. Determining the best recipient vessel site for autologous microsurgical breast reconstruction with DIEP flaps: An anatomical study.

    Science.gov (United States)

    Lhuaire, Martin; Hivelin, Mikael; Dramé, Moustapha; Abrahams, Peter; Kianmanesh, Reza; Fontaine, Christian; Lantieri, Laurent

    2017-06-01

    The deep inferior epigastric perforator (DIEP) flap is a reliable and reproducible technique for autologous microsurgical breast reconstruction. Several recipient vessels sites for microvascular anastomosis have been described such as the internal thoracic vessels, the thoracodorsal vessels, and the circumflex scapular vessels. Nonetheless, the choice of the recipient site depends mainly on individual operator's experience and preferences, and currently the best recipient vessel site is under debate. This anatomical observational study aimed to determine whether anatomy could address this dilemma by determining the best vessel diameter to match the donor with these three recipient sites. Our series reports 80 dissections of the three anatomical regions of interest. Forty formalin-preserved female cadavers were dissected bilaterally. Internal vessels diameter measurements were recorded with a vascular gauge ranging from 1.0 to 5.0 mm with successive half-millimeter graduations. The median diameter of the deep inferior epigastric (DIEA), internal thoracic (ITA), circumflex scapular (CSA), and thoracodorsal arteries (TDA) were: 2.0, 2.5, 2.5, and 1.5 mm, respectively. The median diameter of the deep inferior epigastric, internal thoracic, circumflex scapular, and thoracodorsal veins were: 3.0, 3.0, 3.0, and 2.5 mm, respectively. At the individual level, the perfect match between DIEA and ITA was significantly more frequent than between DIEA and TDA (p = 0.002), and it was more frequent between DIEA and CSA than between DIEA and TDA (p = 0.009). This study supports the use of the internal thoracic pedicle as the first recipient vessel choice, which should be considered, at least anatomically, as the best one with the closest diameter matching with the donor pedicle. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Acquired Techniques

    DEFF Research Database (Denmark)

    Lunde Nielsen, Espen; Halse, Karianne

    2013-01-01

    Acquired Techniques - a Leap into the Archive, at Aarhus School of Architecture. In collaboration with Karianne Halse, James Martin and Mika K. Friis. Following the footsteps of past travelers this is a journey into tools and techniques of the architectural process. The workshop will focus upon...

  11. Lung vessel segmentation in CT images using graph-cuts

    Science.gov (United States)

    Zhai, Zhiwei; Staring, Marius; Stoel, Berend C.

    2016-03-01

    Accurate lung vessel segmentation is an important operation for lung CT analysis. Filters that are based on analyzing the eigenvalues of the Hessian matrix are popular for pulmonary vessel enhancement. However, due to their low response at vessel bifurcations and vessel boundaries, extracting lung vessels by thresholding the vesselness is not sufficiently accurate. Some methods turn to graph-cuts for more accurate segmentation, as it incorporates neighbourhood information. In this work, we propose a new graph-cuts cost function combining appearance and shape, where CT intensity represents appearance and vesselness from a Hessian-based filter represents shape. Due to the amount of voxels in high resolution CT scans, the memory requirement and time consumption for building a graph structure is very high. In order to make the graph representation computationally tractable, those voxels that are considered clearly background are removed from the graph nodes, using a threshold on the vesselness map. The graph structure is then established based on the remaining voxel nodes, source/sink nodes and the neighbourhood relationship of the remaining voxels. Vessels are segmented by minimizing the energy cost function with the graph-cuts optimization framework. We optimized the parameters used in the graph-cuts cost function and evaluated the proposed method with two manually labeled sub-volumes. For independent evaluation, we used 20 CT scans of the VESSEL12 challenge. The evaluation results of the sub-volume data show that the proposed method produced a more accurate vessel segmentation compared to the previous methods, with F1 score 0.76 and 0.69. In the VESSEL12 data-set, our method obtained a competitive performance with an area under the ROC curve of 0.975, especially among the binary submissions.

  12. Have "formal investigations" into fishing vessel losses ceased?

    OpenAIRE

    Reilly, M S

    1987-01-01

    Systematic studies of 618 fishing vessel losses between January 1961 and December 1982 have shown a significantly increased incidence of total losses from 1972 onwards. Comparison of mean pre- and post-1972 rates indicated an increase of 120% from 2.54 to 5.58 losses per 1000 vessels at risk. Parallel examination of the mortality of fishermen from all occupational accidents showed no improvement. For deaths arising from vessel losses alone, the mean crude death rate, for the same periods, inc...

  13. Vessel detection in ultrasound images using deep convolutional neural networks

    OpenAIRE

    Smistad, Erik; Løvstakken, Lasse

    2016-01-01

    Deep convolutional neural networks have achieved great results on image classification problems. In this paper, a new method using a deep convolutional neural network for detecting blood vessels in B-mode ultrasound images is presented. Automatic blood vessel detection may be useful in medical applications such as deep venous thrombosis detection, anesthesia guidance and catheter placement. The proposed method is able to determine the position and size of the vessels in images in real-time. 1...

  14. Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

    Science.gov (United States)

    Ellis, Tayera

    2015-01-01

    Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in

  15. Skeletonization algorithm-based blood vessel quantification using in vivo 3D photoacoustic imaging

    Science.gov (United States)

    Meiburger, K. M.; Nam, S. Y.; Chung, E.; Suggs, L. J.; Emelianov, S. Y.; Molinari, F.

    2016-11-01

    Blood vessels are the only system to provide nutrients and oxygen to every part of the body. Many diseases can have significant effects on blood vessel formation, so that the vascular network can be a cue to assess malicious tumor and ischemic tissues. Various imaging techniques can visualize blood vessel structure, but their applications are often constrained by either expensive costs, contrast agents, ionizing radiations, or a combination of the above. Photoacoustic imaging combines the high-contrast and spectroscopic-based specificity of optical imaging with the high spatial resolution of ultrasound imaging, and image contrast depends on optical absorption. This enables the detection of light absorbing chromophores such as hemoglobin with a greater penetration depth compared to purely optical techniques. We present here a skeletonization algorithm for vessel architectural analysis using non-invasive photoacoustic 3D images acquired without the administration of any exogenous contrast agents. 3D photoacoustic images were acquired on rats (n  =  4) in two different time points: before and after a burn surgery. A skeletonization technique based on the application of a vesselness filter and medial axis extraction is proposed to extract the vessel structure from the image data and six vascular parameters (number of vascular trees (NT), vascular density (VD), number of branches (NB), 2D distance metric (DM), inflection count metric (ICM), and sum of angles metric (SOAM)) were calculated from the skeleton. The parameters were compared (1) in locations with and without the burn wound on the same day and (2) in the same anatomic location before (control) and after the burn surgery. Four out of the six descriptors were statistically different (VD, NB, DM, ICM, p  <  0.05) when comparing two anatomic locations on the same day and when considering the same anatomic location at two separate times (i.e. before and after burn surgery). The study demonstrates an

  16. [Ultrasound of the large abdominal vessels].

    Science.gov (United States)

    Oviedo-García, A A; Algaba-Montes, M; Segura-Grau, A; Rodríguez-Lorenzo, Á

    2016-01-01

    Ultrasound has recently become an indispensable tool for the family physician, whether exercised in primary care and emergency department; and likewise it has spread to many other specialties: internal medicine, critical care, neurology, pneumology, digestive, etc. and that ultrasound has proven to be a safe diagnostic tool and have great capacity. We firmly believe that ultrasound done to «bedside» the patient by the family doctor, can greatly complement the physical examination and greatly improve clinical effectiveness, allowing the browser an immediate view of the anatomy and physiology of certain structures. It is within this context is particularly relevant ultrasonography of the Aorta and large abdominal vessels, made by the family doctor or the emergency itself, which will develop along this chapter. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Blood vessel segmentation in magnetic resonance angiography imagery

    Science.gov (United States)

    Kozaitis, S. P.; Chandramohan, R.

    2011-06-01

    Small blood vessels may be difficult to detect in magnetic resonance angiography due to the lack of blood flow caused by disease or injury. Our method, which uses a block-matching denoising approach to segment blood vessels, works well in the presence of noise. We examined extended regions of an image to determine whether they contained blood vessels by fitting a Gaussian mixture model to a region's histogram. Then, dissimilar regions were denoised separately. This approach was beneficial in low-contrast settings. It can be used to detect higher-order blood vessels that may be difficult to detect under normal conditions.

  18. Application of lightweighting technology to military aircraft, vessels, and vehicles

    National Research Council Canada - National Science Library

    2012-01-01

    .... Application of lightweighting technology to military aircraft, vessels, and vehicles assesses the current state of lightweighting implementation in land, sea, and air vehicles and recommends ways...

  19. Hygro-Thermo-Mechanical Analysis of a Reactor Vessel

    Directory of Open Access Journals (Sweden)

    Jaroslav Kruis

    2012-01-01

    Full Text Available Determining the durability of a reactor vessel requires a hygro-thermo-mechanical analysis of the vessel throughout its service life. Damage, prestress losses, distribution of heat and moisture and some other quantities are needed for a durability assessment. A coupled analysis was performed on a two-level model because of the huge demands on computer hardware. This paper deals with a hygro-thermo-mechanical analysis of a reactor vessel made of prestressed concrete with a steel inner liner. The reactor vessel is located in Temelín, Czech Republic.

  20. NDE and Stress Monitoring on Composite Overwrapped Pressure Vessels Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Damage caused by composite overwrapped pressure vessels (COPVs) failure can be catastrophic. Thus, monitoring condition and stress in the composite overwrap,...

  1. Dynamic stroma reorganization drives blood vessel dysmorphia during glioma growth.

    Science.gov (United States)

    Mathivet, Thomas; Bouleti, Claire; Van Woensel, Matthias; Stanchi, Fabio; Verschuere, Tina; Phng, Li-Kun; Dejaegher, Joost; Balcer, Marly; Matsumoto, Ken; Georgieva, Petya B; Belmans, Jochen; Sciot, Raf; Stockmann, Christian; Mazzone, Massimiliano; De Vleeschouwer, Steven; Gerhardt, Holger

    2017-10-16

    Glioma growth and progression are characterized by abundant development of blood vessels that are highly aberrant and poorly functional, with detrimental consequences for drug delivery efficacy. The mechanisms driving this vessel dysmorphia during tumor progression are poorly understood. Using longitudinal intravital imaging in a mouse glioma model, we identify that dynamic sprouting and functional morphogenesis of a highly branched vessel network characterize the initial tumor growth, dramatically changing to vessel expansion, leakage, and loss of branching complexity in the later stages. This vascular phenotype transition was accompanied by recruitment of predominantly pro-inflammatory M1-like macrophages in the early stages, followed by in situ repolarization to M2-like macrophages, which produced VEGF-A and relocate to perivascular areas. A similar enrichment and perivascular accumulation of M2 versus M1 macrophages correlated with vessel dilation and malignancy in human glioma samples of different WHO malignancy grade. Targeting macrophages using anti-CSF1 treatment restored normal blood vessel patterning and function. Combination treatment with chemotherapy showed survival benefit, suggesting that targeting macrophages as the key driver of blood vessel dysmorphia in glioma progression presents opportunities to improve efficacy of chemotherapeutic agents. We propose that vessel dysfunction is not simply a general feature of tumor vessel formation, but rather an emergent property resulting from a dynamic and functional reorganization of the tumor stroma and its angiogenic influences. © 2017 The Authors. Published under the terms of the CC BY 4.0 license.

  2. Alternative welding reconditioning solutions without post welding heat treatment of pressure vessel

    Science.gov (United States)

    Cicic, D. T.; Rontescu, C.; Bogatu, A. M.; Dijmărescu, M. C.

    2017-08-01

    In pressure vessels, working on high temperature and high pressure may appear some defects, cracks for example, which may lead to failure in operation. When these nonconformities are identified, after certain examination, testing and result interpretation, the decision taken is to repair or to replace the deteriorate component. In the current legislation it’s stipulated that any repair, alteration or modification to an item of pressurised equipment that was originally post-weld heat treated after welding (PWHT) should be post-weld heat treated again after repair, requirement that cannot always be respected. For that reason, worldwide, there were developed various welding repair techniques without PWHT, among we find the Half Bead Technique (HBT) and Controlled Deposition Technique (CDT). The paper presents the experimental results obtained by applying the welding reconditioning techniques HBT and CDT in order to restore as quickly as possible the pressure vessels made of 13CrMo4-5. The effects of these techniques upon the heat affected zone are analysed, the graphics of the hardness variation are drawn and the resulted structures are compared in the two cases.

  3. Single vessel air injection estimates of xylem resistance to cavitation are affected by vessel network characteristics and sample length.

    Science.gov (United States)

    Venturas, Martin D; Rodriguez-Zaccaro, F Daniela; Percolla, Marta I; Crous, Casparus J; Jacobsen, Anna L; Pratt, R Brandon

    2016-10-01

    Xylem resistance to cavitation is an important trait that is related to the ecology and survival of plant species. Vessel network characteristics, such as vessel length and connectivity, could affect the spread of emboli from gas-filled vessels to functional ones, triggering their cavitation. We hypothesized that the cavitation resistance of xylem vessels is randomly distributed throughout the vessel network. We predicted that single vessel air injection (SVAI) vulnerability curves (VCs) would thus be affected by sample length. Longer stem samples were predicted to appear more resistant than shorter samples due to the sampled path including greater numbers of vessels. We evaluated the vessel network characteristics of grapevine (Vitis vinifera L.), English oak (Quercus robur L.) and black cottonwood (Populus trichocarpa Torr. & A. Gray), and constructed SVAI VCs for 5- and 20-cm-long segments. We also constructed VCs with a standard centrifuge method and used computer modelling to estimate the curve shift expected for pathways composed of different numbers of vessels. For all three species, the SVAI VCs for 5 cm segments rose exponentially and were more vulnerable than the 20 cm segments. The 5 cm curve shapes were exponential and were consistent with centrifuge VCs. Modelling data supported the observed SVAI VC shifts, which were related to path length and vessel network characteristics. These results suggest that exponential VCs represent the most realistic curve shape for individual vessel resistance distributions for these species. At the network level, the presence of some vessels with a higher resistance to cavitation may help avoid emboli spread during tissue dehydration. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Weight optimization of offshore supply vessel based on structural analysis using finite element meth

    Directory of Open Access Journals (Sweden)

    Ahmed M.H. Elhewy

    2016-06-01

    Full Text Available Ship design process usually relies on statistics and comparisons with existing ships, rather than analytical approaches and optimization techniques. Designers found this way as the best to fulfil the owner’s requirements, but better solutions, for both the shipyard and the owner may exist. Assessing ship life cycle cost is one of the most attractive tasks for shipyard during early design stage. Structural optimization can be used to achieve that task. In this paper, a comprehensive study on the structural optimization of an offshore supply vessel (OSV, as a case study, is presented. Detailed structural modeling of the vessel is created. Various environmental loads acting on the ship hull such as still water loads and wave induced loads are briefly explained. Different loading conditions and corresponding structural responses have been investigated to assign the most severe one on the vessel. The basic concept of structural optimization and optimization characteristics is highlighted. Blind search optimization technique is applied and approximately forty-two percent weight and cost savings are found by comparing the weight of various design scenarios together without showing any structural inadequacy.

  5. [Microsurgical blood vessel sutures using the so-called fibrin adhesive].

    Science.gov (United States)

    Meyermann, R; Ahyai, A; Pini, C

    1982-01-01

    Since the development of microvascular surgery by Jacobson and Suarez, adaptation of vessel ends of less than 1 mm diameter has been performed by means of 8-10 interrupted sutures. Even the finest suture material, however, produces a foreign body reaction. In addition, necrosis of the media can be seen after insertion of interrupted sutures. After the initial demonstration in 1940 that divided nerves could be successfully rejoined by means of factors from the blood coagulation system, this technique was introduced to microsurgery in 1977. The present investigation was carried out on 50 end-to-end anastomoses in rat common carotid arteries. Subsequently, the healing process was studied by light and electron microscopy. The adhesive used was fibrinogen cryoprecipitate (Fibrinkleber-Human-Immuno), which polymerises after simultaneous application of thrombin. Electron microscopy shows no basic difference between the healing after this technique and the healing process after trauma to the vessel wall. This method, however, prevents regional necrosis of the vessel wall and reduces intimal thickening. The condition of the intimal lining appears better than in sutured anastomoses. The question, whether this change is due only to the absence of sutures or due also to application of fibrinogen, cannot be answered, however.

  6. Dating Techniques

    Indian Academy of Sciences (India)

    Absolute dating technique (such as stylistic affiliation, association with datable deposits, amino acid study of protein in pigments, and direct radiocarbon dating of the organic fraction of pigments or desert varnish).

  7. Towards cavitation-enhanced permeability in blood vessel on a chip

    Science.gov (United States)

    De Luca, R.; Silvani, G.; Scognamiglio, C.; Sinibaldi, G.; Peruzzi, G.; Chinappi, M.; Kiani, M. F.; Casciola, C. M.

    2017-08-01

    The development of targeted delivery systems releasing pharmaceutical agents directly at the desired site of action may improve their therapeutic efficiency while minimizing damage to healthy tissues, toxicity to the patient and drug waste. In this context, we have developed a bio-inspired microdevice mimicking the tumour microvasculature which represents a valuable tool for assessing the enhancement of blood vessel permeability due to cavitation. This novel system allows us to investigate the effects of ultrasound-driven microbubbles that temporarily open the endothelial intercellular junctions allowing drug to extravasate blood vessels into tumour tissues. The blood vessel on a chip consists of a tissue chamber and two independent vascular channels (width 200 µm, height 100 µm, length 2762 µm) cultured with endothelial cells placed side-by-side and separated by a series of 3 µm pores. Its geometry and dimensions mimic the three-dimensional morphology, size and flow characteristics of microvessels in vivo. The early stage of this project had a twofold objective: 1. To define the protocol for culturing of Human Umbilical Vein Endothelial Cells (HUVECs) within the vascular channel; 2. To develop a fluorescence based microscopy technique for measuring permeability. We have developed a reliable and reproducible protocol to culture endothelial cells within the artificial vessels in a realistic manner: HUVECs show the typical elongated shape in the direction of flow, exhibit tight junction formation and form a continuous layer with a central lumen that completely covers the channels wall. As expected, the permeability of cell-free device is higher than the one cultured with HUVECs in the vascular channels. The proposed blood vessel on a chip and the permeability measurement protocol have a significant potential to allow for the study of cavitation-enhanced permeability of the endothelium and improve efficiency in screening drug delivery systems.

  8. Intensity techniques

    DEFF Research Database (Denmark)

    Jacobsen, Finn

    2008-01-01

    The Handbook of Signal Processing in Acoustics will compile the techniques and applications of signal processing as they are used in the many varied areas of Acoustics. The Handbook will emphasize the interdisciplinary nature of signal processing in acoustics. Each Section of the Handbook...... from different areas, will find the self-contained chapters accessible and will be interested in the similarities and differences between the approaches and techniques used in different areas of acoustics....

  9. Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties

    Science.gov (United States)

    Chen, Alvin I.; Balter, Max L.; Chen, Melanie I.; Gross, Daniel; Alam, Sheikh K.; Maguire, Timothy J.; Yarmush, Martin L.

    2016-01-01

    work simulate the mechanical, optical, and acoustic properties of human skin tissues, vessel tissue, and blood. In this way, the phantoms are uniquely suited to serve as test models for multimodal imaging techniques and image-guided interventions. PMID:27277058

  10. Bioinspired Coordinated Path Following for Vessels with Speed Saturation Based on Virtual Leader

    Directory of Open Access Journals (Sweden)

    Mingyu Fu

    2016-01-01

    Full Text Available This paper investigates the coordinated path following of multiple marine vessels with speed saturation. Based on virtual leader strategy, the authors show how the neural dynamic model and passivity-based techniques are brought together to yield a distributed control strategy. The desired path following is achieved by means of a virtual dynamic leader, whose controller is designed based on the biological neural shunting model. Utilizing the characteristic of bounded and smooth output of neural dynamic model, the tracking error jump is avoided and speed saturation problem is solved in straight path. Meanwhile, the coordinated path following of multiple vessels with a desired spatial formation is achieved through defining the formation reference point. The consensus of formation reference point is realized by using the synchronization controller based on passivity. Finally, simulation results validate the effectiveness of the proposed coordinated algorithm.

  11. Multiplane magnetic resonance imaging of the heart and major vessels: studies in normal volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Higgins, C.B.; Stark, D.; McNamara, M.; Lanzer, P.; Crooks, L.E.; Kaufman, L.

    1984-04-01

    The feasibility of magnetic resonance imaging for defining anatomy of internal cardiac structures and major blood vessels was assessed in 14 normal subjects. Both electrocardiogram-gated and standard spin-echo images were obtained. Gated images provided better visualization of internal cardiac morphology and of upper mediastinal vessels than did nongated images. Trabecular detail and components of the mitral valve could be resolved. All segments of the left ventricular wall could be evaluated by combining axial, coronal, and sagittal images. Gated acquisition of magnetic resonance images did not increase imaging time; five transverse slices of the left ventricle were obtained in 6.0-8.5 min. The good image quality, ease of gated acquisition, large field of view, capability of direct imaging in multiple planes, and noninvasiveness of the technique suggest that it will be an important imaging method in cardiovascular disease.

  12. A Constraint Programming model for fast optimal stowage of container vessel bays

    DEFF Research Database (Denmark)

    Delgado, Alberto; Jensen, Rune Møller; Janstrup, Kira

    2012-01-01

    planning phase that distributes the containers to bay sections and a slot planning phase that assigns containers of each bay section to slots. In this paper, we focus on the slot planning phase of this approach and present a Constraint Programming and Integer Programming model for stowing a set......Container vessel stowage planning is a hard combinatorial optimization problem with both high economic and environmental impact. We have developed an approach that often is able to generate near-optimal plans for large container vessels within a few minutes. It decomposes the problem into a master...... of containers in a single bay section. This so-called slot planning problem is NP-hard and often involves stowing several hundred containers. Using state-of-the-art constraint solvers and modeling techniques, however, we were able to solve 90% of 236 real instances from our industrial collaborator to optimality...

  13. Retinal vessel enhancement based on the Gaussian function and image fusion

    Science.gov (United States)

    Moraru, Luminita; Obreja, Cristian Dragoş

    2017-01-01

    The Gaussian function is essential in the construction of the Frangi and COSFIRE (combination of shifted filter responses) filters. The connection of the broken vessels and an accurate extraction of the vascular structure is the main goal of this study. Thus, the outcome of the Frangi and COSFIRE edge detection algorithms are fused using the Dempster-Shafer algorithm with the aim to improve detection and to enhance the retinal vascular structure. For objective results, the average diameters of the retinal vessels provided by Frangi, COSFIRE and Dempster-Shafer fusion algorithms are measured. These experimental values are compared to the ground truth values provided by manually segmented retinal images. We prove the superiority of the fusion algorithm in terms of image quality by using the figure of merit objective metric that correlates the effects of all post-processing techniques.

  14. 50 CFR 635.6 - Vessel and gear identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 8 2010-10-01 2010-10-01 false Vessel and gear identification. 635.6 Section 635.6 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC... or aircraft. (ii) In block arabic numerals permanently affixed to or painted on the vessel in...

  15. 75 FR 66309 - Vessel Traffic Service Lower Mississippi River

    Science.gov (United States)

    2010-10-28

    ... consisting of measures for controlling or supervising vessel traffic to protect the marine environment. 33 U... working group. The Coast Guard encourages stakeholders to provide feedback on VTS operations by contacting... supervising vessel traffic to protect the marine environment. In enacting PWSA in 1972, Congress found that...

  16. 33 CFR 104.305 - Vessel Security Assessment (VSA) requirements.

    Science.gov (United States)

    2010-07-01

    ... baggage; and (vi) Vessel stores; (2) Threat assessments, including the purpose and methodology of the... availability of security communications, information, and equipment. (c) Analysis and recommendations. In... may, if damaged or used illicitly, pose a risk to people, property, or operations on board the vessel...

  17. Vessel Monitoring Systems Study. Volume I - Technical Analysis.

    Science.gov (United States)

    1980-09-01

    In the Port and Tanker Safety Act of 1978 the U.S. Conress directed the Department of Transportation to performa a study on the desirability and feasibility of a shore-station system for monitoring vessels (including fishing vessels)offshore within t...

  18. 76 FR 36071 - Atlantic Highly Migratory Species; Vessel Monitoring Systems

    Science.gov (United States)

    2011-06-21

    ... agents have also reported difficulty communicating with vessels when needed, such as when closed areas... professionally installed and used to replace the dated MTU VMS units, NMFS will ensure that newer, more reliable... enforcement agents with the ability to communicate directly with vessels at sea via electronic messaging and...

  19. 40 CFR 63.646 - Storage vessel provisions.

    Science.gov (United States)

    2010-07-01

    ...) National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries § 63.646 Storage vessel... operator may use good engineering judgment or test results to determine the stored liquid weight percent... 63.120(b)(10)(iii) for all or some storage vessels at petroleum refineries subject to this subpart...

  20. Information Sharing of Vessel Traffic Service (VTS) and Maritime ...

    African Journals Online (AJOL)

    The marine information system provides a central database with online access to support the monitoring of violating vessels, aid to navigation. The system provides emergency response to increase safety within marine activities. Violating vessels data registered by the VTS is collected as evidence for assessment.

  1. The Cape commercial linefishery consists of about 2 500 vessels ...

    African Journals Online (AJOL)

    spamer

    engines, nylon lines, echo-sounders, electronic navigational aids, onboard freezer facilities and larger vessels, declines in catch rate indicative ... Most of these were higher-trophic-level species from the warm/temperate. East Coast, several of which .... of vessels active at each of several fishing centres were obtained for the ...

  2. What are the residual stresses doing in our blood vessels?

    Science.gov (United States)

    Fung, Y C

    1991-01-01

    We show that the residual strain and stress in the blood vessels are not zero, and that the zero-stress state of a blood vessel consists of open-sector segments whose opening angles vary along the longitudinal axis of the vessel. When the homeostatic state of the blood vessel is changed, e.g., by a sudden hypertension, the opening angle will change. The time constant of the opening angle change is a few hours (e.g., in the pulmonary artery) or a few days (e.g., in the aorta). From a kinematic point of view, a change of opening angle is a bending of the blood vessel wall, which is caused by a nonuniformly distributed residual strain. From a mechanics point of view, changes of blood pressure and residual strain cause change of stress in the blood vessel wall. Correlating the stress with the change of residual strain yields a fundamental biological law relating the rate of growth or resorption of tissue with the stress in the tissue. Thus, residual stresses are related to the remodeling of the blood vessel wall. Our blood vessel remodels itself when stress changes. The stress-growth law provides a biomechanical foundation for tissue engineering.

  3. Diaphragmatic lymphatic vessel behavior during local skeletal muscle contraction.

    Science.gov (United States)

    Moriondo, Andrea; Solari, Eleonora; Marcozzi, Cristiana; Negrini, Daniela

    2015-02-01

    The mechanism through which the stresses developed in the diaphragmatic tissue during skeletal muscle contraction sustain local lymphatic function was studied in 10 deeply anesthetized, tracheotomized adult Wistar rats whose diaphragm was exposed after thoracotomy. To evaluate the direct effect of skeletal muscle contraction on the hydraulic intraluminal lymphatic pressures (Plymph) and lymphatic vessel geometry, the maximal contraction of diaphragmatic fibers adjacent to a lymphatic vessel was elicited by injection of 9.2 nl of 1 M KCl solution among diaphragmatic fibers while Plymph was recorded through micropuncture and vessel geometry via stereomicroscopy video recording. In lymphatics oriented perpendicularly to the longitudinal axis of muscle fibers and located at 900 μm from the vessel, Dmc enlarged to 131.1 ± 2.3% of Drest. In vessels parallel to muscle fibers, Dmc increased to 122.8 ± 2.9% of Drest. During contraction, Plymph decreased as much as 22.5 ± 2.6 cmH2O in all submesothelial superficial vessels, whereas it increased by 10.7 ± 5.1 cmH2O in deeper vessels running perpendicular to contracting muscle fibers. Hence, the three-dimensional arrangement of the diaphragmatic lymphatic network seems to be finalized to efficiently exploit the stresses exerted by muscle fibers during the contracting inspiratory phase to promote lymph formation in superficial submesothelial lymphatics and its further propulsion in deeper intramuscular vessels. Copyright © 2015 the American Physiological Society.

  4. 76 FR 75492 - Atlantic Highly Migratory Species; Vessel Monitoring Systems

    Science.gov (United States)

    2011-12-02

    ... rather than cell towers as the principle means of transmitting data. Furthermore, vessels need to provide position reports every hour when they are away from port, and cell phones cannot consistently provide that... and fishing gears possessed to be made by phone. Some small fishing vessels remain within cell phone...

  5. Clustering vessel trajectories with alignment kernels under trajectory compression

    NARCIS (Netherlands)

    de Vries, G.; van Someren, M.

    2010-01-01

    In this paper we apply a selection of alignment measures, such as dynamic time warping and edit distance, to the problem of clustering vessel trajectories. Vessel trajectories are an example of moving object trajectories, which have recently become an important research topic. The alignment measures

  6. A model based method for retinal blood vessel detection

    NARCIS (Netherlands)

    Vermeer, K. A.; Vos, F. M.; Lemij, H. G.; Vossepoel, A. M.

    2004-01-01

    Retinal blood vessels are important structures in ophthalmological images. Many detection methods are available, but the results are not always satisfactory. In this paper, we present a novel model based method for blood vessel detection in retinal images. It is based on a Laplace and thresholding

  7. 46 CFR 154.409 - Dynamic loads from vessel motion.

    Science.gov (United States)

    2010-10-01

    ... to the probability level of 10−8, by using one of the following methods: (1) Method 1 is a detailed analysis of the vessel's acceleration components. (2) Method 2 applies to vessels of 50 m (164 ft) or more in length and is an analysis by the following formulae that corresponds to a 10−8 probability level...

  8. Pathogenesis and pathology of HIVrelated large-vessel disease ...

    African Journals Online (AJOL)

    The first reported series of large-vessel aneurysms in patients with HIV infection emanated from Zimbabwe.1,2 A more comprehensive study of the pathology was reported by Nair et al. in 1999.3 More recently there has been some focus on occlusive large-vessel disease, with separate reports by Nair et al.4 and Mulaudzi et ...

  9. A note on vessels in Hypolytreae of Cyperaceae

    NARCIS (Netherlands)

    Cheadle, Vernon I.; Kosakai, Hatsume

    1974-01-01

    In an earlier paper (Cheadle and Kosakai, 1972) on vessels in Cyperaceae we had available only two genera ( Chorizandra and Chrysithrix) and two species of the tribe Hypolytreae. This was unfortunate, for it turned out that Hypolytreae has the most primitive vessels on the whole. After reading the

  10. 46 CFR 188.10-53 - Oceanographic research vessel.

    Science.gov (United States)

    2010-10-01

    ... research, including those studies about the sea such as seismic, gravity meter, and magnetic exploration... 46 Shipping 7 2010-10-01 2010-10-01 false Oceanographic research vessel. 188.10-53 Section 188.10-53 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS...

  11. 49 CFR 176.145 - Segregation in single hold vessels.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Segregation in single hold vessels. 176.145 Section 176.145 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... VESSEL Detailed Requirements for Class 1 (Explosive) Materials Segregation § 176.145 Segregation in...

  12. 33 CFR 164.19 - Requirements for vessels at anchor.

    Science.gov (United States)

    2010-07-01

    ... anchor. 164.19 Section 164.19 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... vessels at anchor. The master or person in charge of each vessel that is anchored shall ensure that: (a) A proper anchor watch is maintained; (b) Procedures are followed to detect a dragging anchor; and (c...

  13. Keeping control when cutting through a reactor vessel

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1997-09-01

    UK Robotics` Advanced Teleoperation Controller (ATC) is a key component of one of the most extensive remote handling operations currently being undertaken - the removal of 165 mm diameter, 90 mm thick samples of carbon-manganese steel from the base of the Trawsfyndd reactor pressure vessel. These will then be used to assess the material properties of the vessel welds. (author).

  14. Some functional and adaptive aspects of vessel member morphology

    NARCIS (Netherlands)

    Baas, P.

    1976-01-01

    The hypothesis of functionally adaptive diversification of wood structure in the course of evolution as advanced by Carlquist is critically tested for vessel member length and type of perforation plate. The functional significance of within-tree variation in vessel member morphology is discussed

  15. 19 CFR 4.90 - Simultaneous vessel transactions.

    Science.gov (United States)

    2010-04-01

    ... transactions. (a) A vessel may proceed from port to port in the United States for the purpose of engaging in two or more of the following transactions simultaneously, 121 subject to the limitations hereafter... 19 Customs Duties 1 2010-04-01 2010-04-01 false Simultaneous vessel transactions. 4.90 Section 4...

  16. Neovascularisation of the ovary post ligation of ovarian vessels in ...

    African Journals Online (AJOL)

    The viable ovarian tissues noticed on histology were evidence of revascularization suggestive of newer invasion of blood vessels from the ovarian attachment from the retroperitoneal tissues and likely from the subcutaneous supplies. Consequently, it is not advisable to neuter a bitch by ligation of the ovarian vessels ...

  17. Summary of Reported Whale-Vessel Collisions in Alaskan Waters

    Directory of Open Access Journals (Sweden)

    Janet L. Neilson

    2012-01-01

    Full Text Available Here we summarize 108 reported whale-vessel collisions in Alaska from 1978–2011, of which 25 are known to have resulted in the whale's death. We found 89 definite and 19 possible/probable strikes based on standard criteria we created for this study. Most strikes involved humpback whales (86% with six other species documented. Small vessel strikes were most common (<15 m, 60%, but medium (15–79 m, 27% and large (≥80 m, 13% vessels also struck whales. Among the 25 mortalities, vessel length was known in seven cases (190–294 m and vessel speed was known in three cases (12–19 kn. In 36 cases, human injury or property damage resulted from the collision, and at least 15 people were thrown into the water. In 15 cases humpback whales struck anchored or drifting vessels, suggesting the whales did not detect the vessels. Documenting collisions in Alaska will remain challenging due to remoteness and resource limitations. For a better understanding of the factors contributing to lethal collisions, we recommend (1 systematic documentation of collisions, including vessel size and speed; (2 greater efforts to necropsy stranded whales; (3 using experienced teams focused on determining cause of death; (4 using standard criteria for validating collision reports, such as those presented in this paper.

  18. Interpretation of Strain Measurements on Nuclear Pressure Vessels

    DEFF Research Database (Denmark)

    Andersen, Svend Ib Smidt; Engbæk, Preben

    1980-01-01

    Selected results from strain measurements on four nuclear pressure vessels are presented and discussed. The measurements were made in several different regions of the vessels: transition zones in vessel heads, flanges and bottom parts, nozzles, internal vessel structure and flange bolts. The resu......Selected results from strain measurements on four nuclear pressure vessels are presented and discussed. The measurements were made in several different regions of the vessels: transition zones in vessel heads, flanges and bottom parts, nozzles, internal vessel structure and flange bolts....... The results presented are based on data obtained by approximately 700 strain-gauges, and a comprehensive knowledge of the quality obtained by such measurements is established. It is shown that a thorough control procedure before and after the test as well as a detailed knowledge of the behaviour of the signal...... from the individual gauges during the test is necessary. If this is omitted, it can be extremely difficult to distinguish between the real structural behaviour and a malfunctioning of a specific gauge installation. In general, most of the measuring results exhibit a very linear behaviour...

  19. Root resistance to cavitation is accurately measured using a centrifuge technique.

    Science.gov (United States)

    Pratt, R B; MacKinnon, E D; Venturas, M D; Crous, C J; Jacobsen, A L

    2015-02-01

    Plants transport water under negative pressure and this makes their xylem vulnerable to cavitation. Among plant organs, root xylem is often highly vulnerable to cavitation due to water stress. The use of centrifuge methods to study organs, such as roots, that have long vessels are hypothesized to produce erroneous estimates of cavitation resistance due to the presence of open vessels through measured samples. The assumption that roots have long vessels may be premature since data for root vessel length are sparse; moreover, recent studies have not supported the existence of a long-vessel artifact for stems when a standard centrifuge technique was used. We examined resistance to cavitation estimated using a standard centrifuge technique and compared these values with native embolism measurements for roots of seven woody species grown in a common garden. For one species we also measured vulnerability using single-vessel air injection. We found excellent agreement between root native embolism and the levels of embolism measured using a centrifuge technique, and with air-seeding estimates from single-vessel injection. Estimates of cavitation resistance measured from centrifuge curves were biologically meaningful and were correlated with field minimum water potentials, vessel diameter (VD), maximum xylem-specific conductivity (Ksmax) and vessel length. Roots did not have unusually long vessels compared with stems; moreover, root vessel length was not correlated to VD or to the vessel length of stems. These results suggest that root cavitation resistance can be accurately and efficiently measured using a standard centrifuge method and that roots are highly vulnerable to cavitation. The role of root cavitation resistance in determining drought tolerance of woody species deserves further study, particularly in the context of climate change. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Decomposition techniques

    Science.gov (United States)

    Chao, T.T.; Sanzolone, R.F.

    1992-01-01

    Sample decomposition is a fundamental and integral step in the procedure of geochemical analysis. It is often the limiting factor to sample throughput, especially with the recent application of the fast and modern multi-element measurement instrumentation. The complexity of geological materials makes it necessary to choose the sample decomposition technique that is compatible with the specific objective of the analysis. When selecting a decomposition technique, consideration should be given to the chemical and mineralogical characteristics of the sample, elements to be determined, precision and accuracy requirements, sample throughput, technical capability of personnel, and time constraints. This paper addresses these concerns and discusses the attributes and limitations of many techniques of sample decomposition along with examples of their application to geochemical analysis. The chemical properties of reagents as to their function as decomposition agents are also reviewed. The section on acid dissolution techniques addresses the various inorganic acids that are used individually or in combination in both open and closed systems. Fluxes used in sample fusion are discussed. The promising microwave-oven technology and the emerging field of automation are also examined. A section on applications highlights the use of decomposition techniques for the determination of Au, platinum group elements (PGEs), Hg, U, hydride-forming elements, rare earth elements (REEs), and multi-elements in geological materials. Partial dissolution techniques used for geochemical exploration which have been treated in detail elsewhere are not discussed here; nor are fire-assaying for noble metals and decomposition techniques for X-ray fluorescence or nuclear methods be discussed. ?? 1992.

  1. Design and analysis of multicavity prestressed concrete reactor vessels. [HTGR

    Energy Technology Data Exchange (ETDEWEB)

    Goodpasture, D.W.; Burdette, E.G.; Callahan, J.P.

    1977-01-01

    During the past 25 years, a rather rapid evolution has taken place in the design and use of prestressed concrete reactor vessels (PCRVs). Initially the concrete vessel served as a one-to-one replacement for its steel counterpart. This was followed by the development of the integral design which led eventually to the more recent multicavity vessel concept. Although this evolution has seen problems in construction and operation, a state-of-the-art review which was recently conducted by the Oak Ridge National Laboratory indicated that the PCRV has proven to be a satisfactory and inherently safe type of vessel for containment of gas-cooled reactors from a purely functional standpoint. However, functionalism is not the only consideration in a demanding and highly competitive industry. A summary is presented of the important considerations in the design and analysis of multicavity PCRVs together with overall conclusions concerning the state of the art of these vessels.

  2. Studies on in-vessel debris coolability in ALPHA program

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Yu; Yamano, Norihiro; Moriyama, Kiyofumi [Japan Atomic Energy Research Institute, Ibaraki-ken (Japan)] [and others

    1997-02-01

    In-vessel debris coolability experiments have been performed in ALPHA Program at JAERI. Aluminum oxide (Al{sub 2}O{sub 3}) produced by a thermite reaction was applied as a debris simulant. Two scoping experiments using approximately 30 kg or 50 kg of Al{sub 2}O{sub 3} were conducted. In addition to post-test observations, temperature histories of the debris simulant and the lower head experimental vessel were evaluated. Rapid temperature reduction observed on the outer surface of the experimental vessel may imply that water penetration into a gap between the solidified debris and the experimental vessel occurred resulting in an effective cooling of once heated vessel wall. Preliminary measurement of a gap width was made with an ultrasonic device. Signals to show the existence of gaps, ranging from 0.7 mm to 1.4 mm, were detected at several locations.

  3. Nuclear reactor construction with bottom supported reactor vessel

    Science.gov (United States)

    Sharbaugh, John E.

    1987-01-01

    An improved liquid metal nuclear reactor construction has a reactor core and a generally cylindrical reactor vessel for holding a large pool of low pressure liquid metal coolant and housing the core within the pool. The reactor vessel has an open top end, a closed flat bottom end wall and a continuous cylindrical closed side wall interconnecting the top end and bottom end wall. The reactor also has a generally cylindrical concrete containment structure surrounding the reactor vessel and being formed by a cylindrical side wall spaced outwardly from the reactor vessel side wall and a flat base mat spaced below the reactor vessel bottom end wall. A central support pedestal is anchored to the containment structure base mat and extends upwardly therefrom to the reactor vessel and upwardly therefrom to the reactor core so as to support the bottom end wall of the reactor vessel and the lower end of the reactor core in spaced apart relationship above the containment structure base mat. Also, an annular reinforced support structure is disposed in the reactor vessel on the bottom end wall thereof and extends about the lower end of the core so as to support the periphery thereof. In addition, an annular support ring having a plurality of inward radially extending linear members is disposed between the containment structure base mat and the bottom end of the reactor vessel wall and is connected to and supports the reactor vessel at its bottom end on the containment structure base mat so as to allow the reactor vessel to expand radially but substantially prevent any lateral motions that might be imposed by the occurrence of a seismic event. The reactor construction also includes a bed of insulating material in sand-like granular form, preferably being high density magnesium oxide particles, disposed between the containment structure base mat and the bottom end wall of the reactor vessel and uniformly supporting the reactor vessel at its bottom end wall on the containment

  4. Lymphatic Vessels: The Next Frontier in Lung Transplant.

    Science.gov (United States)

    Cui, Ye; Liu, Kaifeng; Lamattina, Anthony Mark; Visner, Gary; El-Chemaly, Souheil

    2017-09-01

    Lymphatic vessels are essential for the uptake of fluid, immune cells, macromolecules, and lipids from the interstitial space. During lung transplant surgery, the pulmonary lymphatic vessel continuum is completely disrupted, and, as a result, lymphatic drainage function is severely compromised. After transplantation, the regeneration of an effective lymphatic drainage system plays a crucial role in maintaining interstitial fluid balance in the lung allograft. In the meantime, these newly formed lymphatic vessels are commonly held responsible for the development of immune responses leading to graft rejection, because they are potentially capable of transporting antigen-presenting cells loaded with allogeneic antigens to the draining lymph nodes. However, despite remarkable progress in the understanding of lymphatic biology, there is still a paucity of consistent evidence that demonstrates the exact impacts of lymphatic vessels on lung graft function. In this review, we examine the current literature related to roles of lymphatic vessels in the pathogenesis of lung transplant rejection.

  5. Roi Detection and Vessel Segmentation in Retinal Image

    Science.gov (United States)

    Sabaz, F.; Atila, U.

    2017-11-01

    Diabetes disrupts work by affecting the structure of the eye and afterwards leads to loss of vision. Depending on the stage of disease that called diabetic retinopathy, there are sudden loss of vision and blurred vision problems. Automated detection of vessels in retinal images is a useful study to diagnose eye diseases, disease classification and other clinical trials. The shape and structure of the vessels give information about the severity of the disease and the stage of the disease. Automatic and fast detection of vessels allows for a quick diagnosis of the disease and the treatment process to start shortly. ROI detection and vessel extraction methods for retinal image are mentioned in this study. It is shown that the Frangi filter used in image processing can be successfully used in detection and extraction of vessels.

  6. Earlywood vessels of Castanea sativa record temperature before their formation.

    Science.gov (United States)

    Fonti, Patrick; Solomonoff, Natalie; García-González, Ignacio

    2007-01-01

    The aim of this study was to identify the climatic signal contained in the earlywood vessel size of the ring-porous chestnut (Castanea sativa) and the physiological processes involved in the underlying mechanisms. In order to assign the encoded signal to a specific physiological process, bud phenology and vessel formation were monitored along an elevation transect and chronologies of the size of the first row of earlywood vessels were retrospectively correlated with 40 yr of early spring temperatures. The first vessels appeared in late April to early May, after encoding both a negative temperature signal in February-March (during tree quiescence) and a positive temperature signal in early April (at the time of resumption of shoot growth). We hypothesize that February and March temperatures affect cambial sensitivity to auxin, preconditioning tree responses later in the season. Furthermore, April temperature is related to tree activation whereby new hormone production fosters vessel expansion.

  7. Curvature affects Doppler investigation of vessels: implications for clinical practice.

    Science.gov (United States)

    Balbis, S; Roatta, S; Guiot, C

    2005-01-01

    In clinical practice, blood velocity estimations from Doppler examination of curved vascular segments are normally different from those of nearby straight segments. The observed "accelerations," sometimes considered as a sort of stochastic disturbances, can actually be related to very specific physical effects due to vessel curvature (i.e., the development of nonaxial velocity [NAV] components) and the spreading of the axial velocity direction in the Doppler sample volume with respect to the insonation axis. The relevant phenomena and their dependence on the radius of curvature of the vessels and on the insonation angle are investigated with a beam-vessel geometry as close as possible to clinical setting, with the simplifying assumptions of steady flow, mild vessel curvature, uniform ultrasonic beam and complete vessel insonation. The insonation angles that minimize the errors are provided on the basis of the study results.

  8. [Bladder injury by penetration of artificial vessel graft].

    Science.gov (United States)

    Wada, Naoki; Tamaki, Gaku; Kura, Tatsuhiko; Saga, Yuji; Kakizaki, Hidehiro

    2009-01-01

    Iatrogenic bladder injury by artificial vessel graft is extremely rare and only 3 cases have been reported. Herein, we report a case of bladder injury by penetration of artificial vessel graft. An 80-year-old male underwent a femoro-femoral crossover bypass surgery for arteriosclerosis obliterans in our hospital. Postoperatively he complained of urinary incontinence and was referred to the urology department. Ultrasonography for evaluating microscopic hematuria revealed a high echoic linear structure in the bladder and subsequent cystoscopy found an artificial vessel graft penetrating bladder wall. Vascular surgeons reconstructed femoro-femoral bypass and we removed the artificial vessel graft and repaired the injured bladder wall. This is the fourth case of bladder penetrating injury by artificial vessel graft and we summarize the reported cases.

  9. In vivo imaging of stepwise vessel occlusion in cerebral photothrombosis of mice by 19F MRI.

    Directory of Open Access Journals (Sweden)

    Gesa Weise

    Full Text Available (19F magnetic resonance imaging (MRI was recently introduced as a promising technique for in vivo cell tracking. In the present study we compared (19F MRI with iron-enhanced MRI in mice with photothrombosis (PT at 7 Tesla. PT represents a model of focal cerebral ischemia exhibiting acute vessel occlusion and delayed neuroinflammation.Perfluorocarbons (PFC or superparamagnetic iron oxide particles (SPIO were injected intravenously at different time points after photothrombotic infarction. While administration of PFC directly after PT induction led to a strong (19F signal throughout the entire lesion, two hours delayed application resulted in a rim-like (19F signal at the outer edge of the lesion. These findings closely resembled the distribution of signal loss on T2-weighted MRI seen after SPIO injection reflecting intravascular accumulation of iron particles trapped in vessel thrombi as confirmed histologically. By sequential administration of two chemically shifted PFC compounds 0 and 2 hours after illumination the different spatial distribution of the (19F markers (infarct core/rim could be visualized in the same animal. When PFC were applied at day 6 the fluorine marker was only detected after long acquisition times ex vivo. SPIO-enhanced MRI showed slight signal loss in vivo which was much more prominent ex vivo indicative for neuroinflammation at this late lesion stage.Our study shows that vessel occlusion can be followed in vivo by (19F and SPIO-enhanced high-field MRI while in vivo imaging of neuroinflammation remains challenging. The timing of contrast agent application was the major determinant of the underlying processes depicted by both imaging techniques. Importantly, sequential application of different PFC compounds allowed depiction of ongoing vessel occlusion from the core to the margin of the ischemic lesions in a single MRI measurement.

  10. Radiation effects on reactor pressure vessel supports

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.E. [Nuclear Regulatory Commission, Washington, DC (United States). Div. of Engineering Technology; Lipinski, R.E. [Idaho National Engineering Lab., Rockville, MD (United States)

    1996-05-01

    The purpose of this report is to present the findings from the work done in accordance with the Task Action Plan developed to resolve the Nuclear Regulatory Commission (NRC) Generic Safety Issue No. 15, (GSI-15). GSI-15 was established to evaluate the potential for low-temperature, low-flux-level neutron irradiation to embrittle reactor pressure vessel (RPV) supports to the point of compromising plant safety. An evaluation of surveillance samples from the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL) had suggested that some materials used for RPV supports in pressurized-water reactors could exhibit higher than expected embrittlement rates. However, further tests designed to evaluate the applicability of the HFIR data to reactor RPV supports under operating conditions led to the conclusion that RPV supports could be evaluated using traditional method. It was found that the unique HFIR radiation environment allowed the gamma radiation to contribute significantly to the embrittlement. The shielding provided by the thick steel RPV shell ensures that degradation of RPV supports from gamma irradiation is improbable or minimal. The findings reported herein were used, in part, as the basis for technical resolution of the issue.

  11. Aqueous Solution Vessel Thermal Model Development II

    Energy Technology Data Exchange (ETDEWEB)

    Buechler, Cynthia Eileen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-28

    The work presented in this report is a continuation of the work described in the May 2015 report, “Aqueous Solution Vessel Thermal Model Development”. This computational fluid dynamics (CFD) model aims to predict the temperature and bubble volume fraction in an aqueous solution of uranium. These values affect the reactivity of the fissile solution, so it is important to be able to calculate them and determine their effects on the reaction. Part A of this report describes some of the parameter comparisons performed on the CFD model using Fluent. Part B describes the coupling of the Fluent model with a Monte-Carlo N-Particle (MCNP) neutron transport model. The fuel tank geometry is the same as it was in the May 2015 report, annular with a thickness-to-height ratio of 0.16. An accelerator-driven neutron source provides the excitation for the reaction, and internal and external water cooling channels remove the heat. The model used in this work incorporates the Eulerian multiphase model with lift, wall lubrication, turbulent dispersion and turbulence interaction. The buoyancy-driven flow is modeled using the Boussinesq approximation, and the flow turbulence is determined using the k-ω Shear-Stress-Transport (SST) model. The dispersed turbulence multiphase model is employed to capture the multiphase turbulence effects.

  12. Embryonic development and malformation of lymphatic vessels.

    Science.gov (United States)

    Wilting, Jörg; Buttler, Kerstin; Rössler, Jochen; Norgall, Susanne; Schweigerer, Lothar; Weich, Herbert A; Papoutsi, Maria

    2007-01-01

    In the human, malformations of lymphatic vessels can be observed as lymphangiectasia, lymphangioma and lymphangiomatosis, with a prevalence of 1.2-2.8 per thousand. Their aetiology is unknown and a causal therapy does not exist. We investigated the origin of lymphatic endothelial cells (LECs) in avian and murine embryos, and compared the molecular profile of LECs from normal and malformed lymphatics of children. In avian embryos, Prox1+ lymphangioblasts are located in the confluence of the cranial and caudal cardinal veins, where the jugular lymph sac (JLS) forms. Cell lineage studies show that the JLS is of venous origin. In contrast, the lymphatics of the dermis are derived from mesenchymal lymphangioblasts located in the dermatomes, suggesting a dual origin of LECs in avian embryos. The same may hold true for murine embryos, where Lyve1+ LEC precursors are found in the cardinal veins, and in the mesenchyme. The mesenchymal cells express the pan-leukocyte marker CD45, indicating a cell type with lymphendothelial and leukocyte characteristics. In the human, such cells might give rise to Kaposi's sarcoma. Microarray analyses of LECs from lymphangiomas of children show a large number of regulated genes, such as VEGFR3. Our studies show that lymphvasculogenesis and lymphangiogenesis occur simultaneously in the embryo, and suggest a function for VEGFR3 in lymphangiomas.

  13. Welding the AT-400A Containment Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Brandon, E.

    1998-11-01

    Early in 1994, the Department of Energy assigned Sandia National Laboratories the responsibility for designing and providing the welding system for the girth weld for the AT-400A containment vessel. (The AT-400A container is employed for the shipment and long-term storage of the nuclear weapon pits being returned from the nation's nuclear arsenal.) Mason Hanger Corporation's Pantex Plant was chosen to be the production facility. The project was successfully completed by providing and implementing a turnkey welding system and qualified welding procedure at the Pantex Plant. The welding system was transferred to Pantex and a pilot lot of 20 AT-400A containers with W48 pits was welded in August 1997. This document is intended to bring together the AT-400A welding system and product (girth weld) requirements and the activities conducted to meet those requirements. This document alone is not a complete compilation of the welding development activities but is meant to be a summary to be used with the applicable references.

  14. Determinants of Vessel Targeting in Vasculitis

    Directory of Open Access Journals (Sweden)

    Gary S. Hoffman

    2004-01-01

    Full Text Available Studies of autoimmune diseases have not yet elucidated why certain organs or vessels become the objects of injury while others are spared. This paper will explore the hypothesis that important differences exist in regions of the aorta that determine vulnerability to diseases, such as atherosclerosis, aortitis, giant cell arteritis and Takayasu's disease. The reader is invited to reassess; (1 whether the aorta is indeed a single homogeneous structure, and (2 whether the initial stage of aortitis (and indeed other diseases considered “autoimmune” may be primarily due to acquired alterations of substrate, that influence unique immune profiles, which by themselves may not be pathogenic. Disease susceptibility and patterns are influenced by many factors that are inborn and acquired. Examples include genetic background, gender, ethnicity, aging, prior and concomitant illnesses, habits, diet, toxin and environmental exposures. Studies of vascular diseases must assess how such variables may affect regional differences in endothelial cells, subendothelial matrix, vascular smooth muscle and the response of each to a variety of stimuli.

  15. Integral experiments on in-vessel coolability and vessel creep: results and analysis of the FOREVER-C1 test

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R.; Nourgaliev, R.R.; Dinh, T.N.; Karbojian, A. [Division of Nuclear Power Safety, Royal Institute of Technology, Drottning Kristinas Vaeg., Stockholm (Sweden)

    1999-07-01

    This paper describes the FOREVER (Failure Of REactor VEssel Retention) experimental program, which is currently underway at the Division of Nuclear Power Safety, Royal Institute of Technology (RIT/NPS). The objectives of the FOREVER experiments are to obtain data and develop validated models (i) on the melt coolability process inside the vessel, in the presence of water (in particular, on the efficacy of the postulated gap cooling to preclude vessel failure); and (ii) on the lower head failure due to the creep process in the absence of water inside and/or outside the lower head. The paper presents the experimental results and analysis of the first FOREVER-C1 test. During this experiment, the 1/10th scale pressure vessel, heated to about 900degC and pressurized to 26 bars, was subjected to creep deformation in a non-stop 24-hours test. The vessel wall displacement data clearly shows different stages of the vessel deformation due to thermal expansion, elastic, plastic and creep processes. The maximum displacement was observed at the lowermost region of the vessel lower plenum. Information on the FOREVER-C1 measured thermal characteristics and analysis of the observed thermal and structural behavior is presented. The coupled nature of thermal and mechanical processes, as well as the effect of other system conditions (such as depressurization) on the melt pool and vessel temperature responses are analyzed. (author)

  16. Miscellaneous Techniques

    Science.gov (United States)

    Jha, Shyam N.

    Nondestructive way of determining the food quality is the need of the hour. Till now major methods such as colour measurements and their modeling; machine vision systems; X-ray, CT and MRI; NIR spectroscopy; electronic nose and tongue; and ultrasonic technology have been discussed in detail. These techniques, in general, are considered to be sophisticated and costly, and therefore probably are not being adopted as fast as it should be. I am however of the reverse opinion. While going through these techniques, it has been seen that majority of quality parameters have been measured and correlated with the signals obtained using different equipment.

  17. 19 CFR 4.85 - Vessels with residue cargo for domestic ports.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Vessels with residue cargo for domestic ports. 4...; DEPARTMENT OF THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Coastwise Procedure § 4.85 Vessels with residue cargo for domestic ports. (a) Any foreign vessel or documented vessel with a registry or, where...

  18. 19 CFR 4.87 - Vessels proceeding foreign via domestic ports.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Vessels proceeding foreign via domestic ports. 4...; DEPARTMENT OF THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Coastwise Procedure § 4.87 Vessels proceeding foreign via domestic ports. (a) Any foreign vessel or documented vessel with a registry may...

  19. Measurement techniques for liquid metals

    Science.gov (United States)

    Ratajczak, M.; Hernández, D.; Richter, T.; Otte, D.; Buchenau, D.; Krauter, N.; Wondrak, T.

    2017-07-01

    The measurement of flow properties of liquid metals, such as flow rate, flow structure and gas distribution, is a challenging task due to the opaqueness, the high temperatures (e. g. 1500 °C for liquid steel or liquid silicon) and the corrosiveness of those fluids. In this paper, a short review about the recent developments of measurement techniques in the framework of the Helmholtz Alliance Liquid Metal Technologies (LIMTECH) is presented. It focuses on the development of contactless inductive measurement techniques exploiting the high electrical conductivity of those melts. These measurement techniques include the contactless inductive flow tomography (CIFT), which is able to reconstruct the mean three-dimensional velocity structure in liquid melts, local Lorentz force velocimetry (local LFV), which enables the local assessment of flows close to the wall, and inductive methods for bubble detection, which are based on mutual inductance tomography (MIT). Additionally, a short overview of contactless inductive flow rate measurement techniques is given. Furthermore, an ultrasound technique called ultrasound transit-time technique (UTTT) will be presented which enables the measurement of position and size of bubbles in large vessels.

  20. Test of 6-in. -thick pressure vessels. Series 3: intermediate test vessel V-7. [PWR and BWR

    Energy Technology Data Exchange (ETDEWEB)

    Merkle, J.G.; Robinson, G.C.; Holz, P.P.; Smith, J.E.; Bryan, R.H.

    1976-08-01

    The test of intermediate test vessel V-7 was a crack-initiation fracture test of a 152-mm-thick (6-in.), 990-mm-OD (39-in.) vessel of ASTM A533, grade B, class 1 steel plate with a sharp outside surface flaw 457 mm (18 in.) long and about 135 mm (5.3 in.) deep. The vessel was heated to 91/sup 0/C (196/sup 0/F) and pressurized hydraulically until leakage through the flaw terminated the test at a peak pressure of 147 MPa (21,350 psi). Fracture toughness data obtained by testing precracked Charpy-V and compact-tension specimens machined from a prolongation of the cylindrical test shell were used in pretest analyses of the flawed vessel. The vessel, as expected, did not burst. Upon depressurization, the ruptured ligament closed so as to maintain static pressure without leakage at about 129 MPa (18,700 psi).

  1. Short time effects of radiotherapy on lymphatic vessels and restorative lymphatic pathways: experimental approaches ina mouse model.

    Science.gov (United States)

    Pastouret, F; Lievens, P; Leduc, O; Bourgeois, P; Tournel, K; Lamote, J; Zirak, C; Leduc, A

    2014-06-01

    Radiotherapy (RT) is an important component in the therapeutic approach to oncologic conditions. This study presents the investigative results on the impact of RT on lymphatic vessels and on the regenerative response of the lymphatic system in a mouse model. We first irradiated 3 groups of ten mice using brachytherapy in a single treatment of 20 Gy. We then performed morphological examination of the irradiated lymphatic vessels using an in vivo microscopic transillumination technique at 2, 4, and 6 weeks. Next we evaluated lymphatic flow using lymphoscintigraphy and in vivo microscopy at 6 to 11 weeks in: 10 additional mice following irradiation as above (IR), in 10 mice following incision of a lymphatic vessel (I), and in a non-treated control group of 10 mice (N). Intact lymphatic vessels were observed in all mice at 2, 4, and 8 weeks following the single dose of radiotherapy in the first group of mice and normal lymphatic flow was fully restored in the irradiated (IR) and incised (I) mice indicating that the reparative substitution lymphatic pathways are functioning normally. We found that following irradiation with one dose of 20 Gy, lymphatic vessels were not visibly damaged and also that lymphatic flow was consistently restored and substitutive lymphatic pathways formed.

  2. Enhancement of downward-facing saturated boiling heat transfer by the cold spray technique

    Energy Technology Data Exchange (ETDEWEB)

    Sohag, Frauk A.; Beck, Faith R.; Mohanta, Lokanath; Cheung, Fan Bill; Segall, Albert E.; Eden, Timothy J.; Potter, John K. [Pennsylvania State University, University Park (United States)

    2017-02-15

    In-vessel retention by passive external reactor vessel cooling under severe accident conditions is a viable approach for retention of radioactive core melt within the reactor vessel. In this study, a new and versatile coating technique known as 'cold spray' that can readily be applied to operating and advanced reactors was developed to form a microporous coating on the outer surface of a simulated reactor lower head. Quenching experiments were performed under simulated in-vessel retention by passive external reactor vessel cooling conditions using test vessels with and without cold spray coatings. Quantitative measurements show that for all angular locations on the vessel outer surface, the local critical heat flux (CHF) values for the coated vessel were consistently higher than the corresponding CHF values for the bare vessel. However, it was also observed for both coated and uncoated surfaces that the local rate of boiling and local CHF limit vary appreciably along the outer surface of the test vessel. Nonetheless, results of this intriguing study clearly show that the use of cold spray coatings could enhance the local CHF limit for downward-facing boiling by > 88%.

  3. Enhancement of Downward-Facing Saturated Boiling Heat Transfer by the Cold Spray Technique

    Directory of Open Access Journals (Sweden)

    Faruk A. Sohag

    2017-02-01

    Full Text Available In-vessel retention by passive external reactor vessel cooling under severe accident conditions is a viable approach for retention of radioactive core melt within the reactor vessel. In this study, a new and versatile coating technique known as “cold spray” that can readily be applied to operating and advanced reactors was developed to form a microporous coating on the outer surface of a simulated reactor lower head. Quenching experiments were performed under simulated in-vessel retention by passive external reactor vessel cooling conditions using test vessels with and without cold spray coatings. Quantitative measurements show that for all angular locations on the vessel outer surface, the local critical heat flux (CHF values for the coated vessel were consistently higher than the corresponding CHF values for the bare vessel. However, it was also observed for both coated and uncoated surfaces that the local rate of boiling and local CHF limit vary appreciably along the outer surface of the test vessel. Nonetheless, results of this intriguing study clearly show that the use of cold spray coatings could enhance the local CHF limit for downward-facing boiling by > 88%.

  4. Aged Lymphatic Vessels and Mast Cells in Perilymphatic Tissues.

    Science.gov (United States)

    Pal, Sarit; Meininger, Cynthia J; Gashev, Anatoliy A

    2017-05-03

    This review provides a comprehensive summary of research on aging-associated alterations in lymphatic vessels and mast cells in perilymphatic tissues. Aging alters structure (by increasing the size of zones with low muscle cell investiture), ultrastructure (through loss of the glycocalyx), and proteome composition with a concomitant increase in permeability of aged lymphatic vessels. The contractile function of aged lymphatic vessels is depleted with the abolished role of nitric oxide and an increased role of lymphatic-born histamine in flow-dependent regulation of lymphatic phasic contractions and tone. In addition, aging induces oxidative stress in lymphatic vessels and facilitates the spread of pathogens from these vessels into perilymphatic tissues. Aging causes the basal activation of perilymphatic mast cells, which, in turn, restricts recruitment/activation of immune cells in perilymphatic tissues. This aging-associated basal activation of mast cells limits proper functioning of the mast cell/histamine/NF-κB axis that is essential for the regulation of lymphatic vessel transport and barrier functions as well as for both the interaction and trafficking of immune cells near and within lymphatic collecting vessels. Cumulatively, these changes play important roles in the pathogenesis of alterations in inflammation and immunity associated with aging.

  5. Lymphatic vessels: new targets for the treatment of inflammatory diseases.

    Science.gov (United States)

    Dieterich, Lothar C; Seidel, Catharina D; Detmar, Michael

    2014-04-01

    The lymphatic system plays an important role in the physiological control of the tissue fluid balance and in the initiation of immune responses. Recent studies have shown that lymphangiogenesis, the growth of new lymphatic vessels and/or the expansion of existing lymphatic vessels, is a characteristic feature of acute inflammatory reactions and of chronic inflammatory diseases. In these conditions, lymphatic vessel expansion occurs at the tissue level but also within the draining lymph nodes. Surprisingly, activation of lymphatic vessel function by delivery of vascular endothelial growth factor-C exerts anti-inflammatory effects in several models of cutaneous and joint inflammation. These effects are likely mediated by enhanced drainage of extravasated fluid and inflammatory cells, but also by lymphatic vessel-mediated modulation of immune responses. Although some of the underlying mechanisms are just beginning to be identified, lymphatic vessels have emerged as important targets for the development of new therapeutic strategies to treat inflammatory conditions. In this context, it is of great interest that some of the currently used anti-inflammatory drugs also potently activate lymphatic vessels.

  6. Confinement Vessel Assay System: Design and Implementation Report

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine C. [Los Alamos National Laboratory; Bourne, Mark M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Evans, Louise [Los Alamos National Laboratory; Mayo, Douglas R. [Los Alamos National Laboratory; Gomez, Cipriano D. [Retired CMR-OPS: OPERATIONS; Miko, David K. [Los Alamos National Laboratory; Salazar, William R. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory

    2012-07-18

    Los Alamos National Laboratory has a number of spherical confinement vessels remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1- to 2-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. We have developed a neutron assay system for the purposes of Materials Control and Accountability (MC&A) measurements of the vessel prior to and after cleanout. We present our approach to confronting the challenges in designing, building, and testing such a system. The system was designed to meet a set of functional and operational requirements. A Monte Carlo model was developed to aid in optimizing the detector design as well as to predict the systematic uncertainty associated with confinement vessel measurements. Initial testing was performed to optimize and determine various measurement parameters, and then the system was characterized using {sup 252}Cf placed a various locations throughout the measurement system. Measurements were also performed with a {sup 252}Cf source placed inside of small steel and HDPE shells to study the effect of moderation. These measurements compare favorably with their MCNPX model equivalent, making us confident that we can rely on the Monte Carlo simulation to predict the systematic uncertainty due to variations in response to material that may be localized at different points within a vessel.

  7. A Vessel Active Contour Model for Vascular Segmentation

    Directory of Open Access Journals (Sweden)

    Yun Tian

    2014-01-01

    Full Text Available This paper proposes a vessel active contour model based on local intensity weighting and a vessel vector field. Firstly, the energy function we define is evaluated along the evolving curve instead of all image points, and the function value at each point on the curve is based on the interior and exterior weighted means in a local neighborhood of the point, which is good for dealing with the intensity inhomogeneity. Secondly, a vascular vector field derived from a vesselness measure is employed to guide the contour to evolve along the vessel central skeleton into thin and weak vessels. Thirdly, an automatic initialization method that makes the model converge rapidly is developed, and it avoids repeated trails in conventional local region active contour models. Finally, a speed-up strategy is implemented by labeling the steadily evolved points, and it avoids the repeated computation of these points in the subsequent iterations. Experiments using synthetic and real vessel images validate the proposed model. Comparisons with the localized active contour model, local binary fitting model, and vascular active contour model show that the proposed model is more accurate, efficient, and suitable for extraction of the vessel tree from different medical images.

  8. Quick and effective hyperpolarization of the membrane potential in intact smooth muscle cells of blood vessels by synchronization modulation electric field.

    Science.gov (United States)

    Zhang, Liping; Fang, Zhihui; Chen, Wei

    2012-06-01

    Blood vessel dilation starts from activation of the Na/K pumps and inward rectifier K channels in the vessel smooth muscle cells, which hyperpolarizes the cell membrane potential and closes the Ca channels. As a result, the intracellular Ca concentration reduces, and the smooth muscle cells relax and the blood vessel dilates. Activation of the Na/K pumps and the membrane potential hyperpolarization plays a critical role in blood vessel functions. Previously, we developed a new technique, synchronization modulation, to control the pump functions by electrically entraining the pump molecules. We have applied the synchronization modulation electric field noninvasively to various intact cells and demonstrated the field-induced membrane potential hyperpolarization. We further applied the electric field to blood vessels and investigated the field induced functional changes of the vessels. In this paper, we report the results in a study of the membrane potential change in the smooth muscle cells of mesenteric blood vessels in response to the oscillating electric field. We found that the synchronization modulation electric field can effectively hyperpolarize the muscle membrane potential quickly in seconds under physiological conditions.

  9. Immunolocalization of lymphatic vessels in human fetal knee joint tissues.

    Science.gov (United States)

    Melrose, James; Little, Christopher B

    2010-08-01

    We immunolocalized lymphatic and vascular blood vessels in 12- and 14-week-old human fetal knee joint tissues using a polyclonal antibody to a lymphatic vascular endothelium specific hyaluronan receptor (LYVE-1) and a monoclonal antibody to podoplanin (mAb D2-40). A number of lymphatic vessels were identified in the stratified connective tissues surrounding the cartilaginous knee joint femoral and tibial rudiments. These tissues also contained small vascular vessels with entrapped red blood cells which were imaged using Nomarsky DIC microscopy. Neither vascular nor lymphatic vessels were present in the knee joint cartilaginous rudiments. The menisci in 12-week-old fetal knees were incompletely demarcated from the adjacent tibial and femoral cartilaginous rudiments which was consistent with the ongoing joint cavitation process at the femoral-tibial junction. At 14 weeks of age the menisci were independent structural entities; they contained a major central blood vessel containing red blood cells and numerous communicating vessels at the base of the menisci but no lymphatic vessels. In contrast to the 12-week-old menisci, the 14-week meniscal rudiments contained abundant CD-31 and CD-34 positive but no lymphatic vessels. Isolated 14-week-old meniscal cells also were stained with the CD-31 and CD 34 antibodies; CD-68 +ve cells, also abundant in the 14-week-old menisci, were detectable to a far lesser degree in the 12-week menisci and were totally absent from the femoral and tibial rudiments. The distribution of lymphatic vessels and tissue macrophages in the fetal joint tissues was consistent with their roles in the clearance of metabolic waste and extracellular matrix breakdown products arising from the rapidly remodelling knee joint tissues.

  10. Simulation of liquid dynamics in a cryogenic mobile vessels

    Directory of Open Access Journals (Sweden)

    E. Lisowski

    2010-07-01

    Full Text Available Technical gases becomes liquid in extremely low temperature ranging minus 200 °C and very high pressure what makes that transportationdevices have to perform very strict requirement. Presented paper shows selected aspect of simulation of liquefied gas sloshing in aspect of requirements that mobile vessels have to fulfill. Mobile vessel which is the object of simulation is a two shell tank with vacuum and layer insulation between shells adapted to 20 ft container. It is assigned for see, railway and road transport and have to follow all of requirements for such transportation systems. Requirements for such tank are enclosed in standard ISO 1496-3 which deals with freight containers and standard EN13530-2 that describes vacuum, cryogenic vessels. The standards EN13530-2 defines that vessels which are to be filled equal or less than 80% should be fitted with surge plates to provide vessel stability and limit dynamic loads. Additionally surge plates area has tobe at least 70% of cross section of the vessel and volume between surge plates shall be not higher than 7.5 m3. Structure of the vessel as well as the surge plate should resist of longitudinal acceleration of 2g. Additionally surge plates shall resists stresses caused by pressure distributed across the area of surge plate and the pressure shall be calculated as mass of liquid between plates and acceleration 2g. In this paper is presented way of simulation of dynamic behavior of liquefied Argon on vessel structure. A numerical methods likeComputational Fluid Dynamics (CFD and Finite Element Analysis (FEA were used for this purpose. Combination of both tools allowedto get pick value of dynamic pressure that arising during acceleration of 2g, which was assumed is 0.2 s and investigate resistance of vessel and container structure. Presented approach is called Fluid – Structure Interaction simulation. In CFD simulation was used Ansys CFX code, while for FEA calculations Pro/Mechanica package.

  11. EDS V26 Containment Vessel Explosive Qualification Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Crocker, Robert W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Haroldsen, Brent L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stofleth, Jerome H. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-11-01

    The objective of the test was to qualify the vessel for its intended use by subjecting it to a 1.25 times overtest. The criteria for success are that the measured strains do not exceed the calculated strains from the vessel analysis, there is no significant additional plastic strain on subsequent tests at the rated design load (shakedown), and there is no significant damage to the vessel and attached hardware that affect form, fit, or function. Testing of the V25 Vessel in 2011 established a precedent for testing V26 [2]. As with V25, two tests were performed to satisfy this objective. The first test used 9 pounds of Composition C-4 (11.25 lbs. TNT-equivalent), which is 125 percent of the design basis load. The second test used 7.2 pounds of Composition C-4 (9 lbs. TNT-equivalent) which is 100 percent of the design basis load. The first test provided the required overtest while the second test served to demonstrate shakedown and the absence of additional plastic deformation. Unlike the V25 vessel, which was mounted in a shipping cradle during testing, the V26 vessel was mounted on the EDS P2U3 trailer prior to testing. Visual inspections of the EDS vessel, surroundings, and diagnostics were completed before and after each test event. This visual inspection included analyzing the seals, fittings, and interior surfaces of the EDS vessel and documenting any abnormalities or damages. Photographs were used to visually document vessel conditions and findings before and after each test event.

  12. Modular scaffolding for assembling the inside of an LNG vessel

    Energy Technology Data Exchange (ETDEWEB)

    Lienhard, R.W.

    1977-11-15

    A new scaffolding arrangement developed by Swiss Fabricating Inc., Pittsburgh, for finishing the inside of LNG vessels offers greater mobility and outrigger adjustability than conventional scaffolding and need not be specially constructed for each job. The scaffolding provides relatively large and open horizontal work areas without cross-bracing or tie rods. The structural steel base is supported from the bottom of the vessel by adjustable screw-jack supports. Adjustable outriggers can be extended to come close to the vessel's sides.

  13. Absence of lymphatic vessels in the developing human sclera.

    Science.gov (United States)

    Schlereth, Simona L; Neuser, Barbara; Herwig, Martina C; Müller, Annette M; Koch, Konrad R; Reitsamer, Herbert A; Schrödl, Falk; Cursiefen, Claus; Heindl, Ludwig M

    2014-08-01

    The adult sclera is free of lymphatic vessels, but contains a net of blood vessels. Whether and when this selectively lymphangiogenic privilege is achieved during embryologic development is not known yet. Therefore, we investigated the developing human sclera for blood- and lymphatic vessels in 34 abortions/stillborns (12-38 weeks of gestation). The probes were subdivided into three groups (group 1: 12-18 weeks of gestation, n = 10; group 2: 19-23 weeks of gestation, n = 13; group 3: 24-38 weeks of gestation, n = 11), and prepared for paraffin sections followed by immunohistochemistry against CD31 to detect blood vessels, and against lymphatic vessel endothelial hyaluronan receptor-1 (LYVE1)/podoplanin to detect lymphatic vessels. We could show, that in the human episclera distinct CD31 + blood vessels are present as early as week of gestation 13. Their amount increased during pregnancy, whereas stromal CD31 + blood vessels were elevated in early pregnancy and regressed with ongoing pregnancy. In the lamina fusca CD31 + blood vessels were absent at any time point investigated. Single LYVE1 + cells were identified primarily in the episclera; their amount decreased significantly with increasing gestational ages (group 1 compared to group 3: p lymphatic vessels were not detectable in the sclera at any gestational ages analyzed. In contrast to the conjunctiva where LYVE1+/podoplanin + lymphatic vessels were detectable as early as week 17, the amount of LYVE1 + cells in the sclera was highest in early pregnancy (group 1), with a significant decrease during continuing pregnancy (p < 0.001). These findings are the first evidence for a fetal lymphangiogenic privilege of the sclera and show, that the fetal human sclera contains CD31 + blood vessels, but is primarily alymphatic. Our findings suggest a strong expression of selectively antilymphangiogenic factors, making the developing sclera a potential model to discern antilymphangiogenic mechanisms

  14. Heat transfer unit and method for prefabricated vessel

    Energy Technology Data Exchange (ETDEWEB)

    Tamburello, David A.; Kesterson, Matthew R; Hardy, Bruce J.

    2017-11-07

    Vessel assemblies, heat transfer units for prefabricated vessels, and methods for heat transfer prefabricated vessel are provided. A heat transfer unit includes a central rod, and a plurality of peripheral rods surrounding the central rod and connected to the central rod. The plurality of peripheral rods are movable between a first collapsed position and a second bowed position, wherein in the second bowed position a midpoint of each of the plurality of peripheral rods is spaced from the central rod relative to in the first position. The heat transfer unit further includes a heat transfer element connected to one of the plurality of peripheral rods.

  15. Electrochemical Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2008-07-20

    Sensitive and selective detection techniques are of crucial importance for capillary electrophoresis (CE), microfluidic chips, and other microfluidic systems. Electrochemical detectors have attracted considerable interest for microfluidic systems with features that include high sensitivity, inherent miniaturization of both the detection and control instrumentation, low cost and power demands, and high compatibility with microfabrication technology. The commonly used electrochemical detectors can be classified into three general modes: conductimetry, potentiometry, and amperometry.

  16. Experimental Techniques

    DEFF Research Database (Denmark)

    Wyer, Jean

    2013-01-01

    Gas-phase ion spectroscopy requires specialised apparatus, both when it comes to measuring photon absorption and light emission (fluorescence). The reason is much lower ion densities compared to solution-phase spectroscopy. In this chapter different setups are described, all based on mass spectro...... in data interpretation, and the advantages and disadvantages of the different techniques are clarified. New instrumental developments involving cryo-cooled storage rings, which show great promise for the future, are briefly touched upon....

  17. Astrophysical techniques

    CERN Document Server

    Kitchin, CR

    2013-01-01

    DetectorsOptical DetectionRadio and Microwave DetectionX-Ray and Gamma-Ray DetectionCosmic Ray DetectorsNeutrino DetectorsGravitational Radiation Dark Matter and Dark Energy Detection ImagingThe Inverse ProblemPhotographyElectronic ImagingScanningInterferometrySpeckle InterferometryOccultationsRadarElectronic ImagesPhotometryPhotometryPhotometersSpectroscopySpectroscopy SpectroscopesOther TechniquesAstrometryPolarimetrySolar StudiesMagnetometryComputers and The Internet.

  18. 78 FR 40891 - Revisions to the Export Administration Regulations: Military Vehicles; Vessels of War...

    Science.gov (United States)

    2013-07-08

    ..., et al. Revisions to the Export Administration Regulations: Military Vehicles; Vessels of War... the Export Administration Regulations: Military Vehicles; Vessels of War; Submersible Vessels..., Department of Commerce. ACTION: Final rule. SUMMARY: This rule adds to the Export Administration Regulations...

  19. 78 FR 30388 - Requested Administrative Waiver of the Coastwise Trade Laws: Vessel SAFARI; Invitation for Public...

    Science.gov (United States)

    2013-05-22

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Maritime Administration Requested Administrative Waiver of the Coastwise Trade Laws: Vessel SAFARI... of the vessel SAFARI is: Intended Commercial Use Of Vessel: ``Sailing charters, tourism''. Geographic...

  20. 76 FR 79763 - Requested Administrative Waiver of the Coastwise Trade Laws: Vessel TANGO; Invitation for Public...

    Science.gov (United States)

    2011-12-22

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Maritime Administration Requested Administrative Waiver of the Coastwise Trade Laws: Vessel TANGO... of the vessel TANGO is: INTENDED COMMERCIAL USE OF VESSEL: ``Sightseeing, sportfishing, scuba diving...

  1. Development of FB-MultiPier dynamic vessel-collision analysis models, phase 2 : [summary].

    Science.gov (United States)

    2014-07-01

    When collisions between large vessels and bridge : supports occur, they can result in significant : damage to bridge and vessel. These collisions : are extremely hazardous, often taking lives on : the vessel and the bridge. Direct costs of repair : a...

  2. Development of FB-MultiPier dynamic vessel-collision analysis models, phase 2.

    Science.gov (United States)

    2014-07-01

    Massive waterway vessels such as barges regularly transit navigable waterways in the U.S. During passages that fall within : the vicinity of bridge structures, vessels may (under extreme circumstances) deviate from the intended vessel transit path. A...

  3. 77 FR 13696 - Requested Administrative Waiver of the Coastwise Trade Laws: Vessel SIREN; Invitation for Public...

    Science.gov (United States)

    2012-03-07

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Maritime Administration Requested Administrative Waiver of the Coastwise Trade Laws: Vessel SIREN... the vessel SIREN is: Intended Commercial Use Of Vessel: ``Sailing charters.'' Geographic Region...

  4. The impact of vessel size on vulnerability curves: data and models for within-species variability in saplings of aspen, Populus tremuloides Michx.

    Science.gov (United States)

    Cai, Jing; Tyree, Melvin T

    2010-07-01

    The objective of this study was to quantify the relationship between vulnerability to cavitation and vessel diameter within a species. We measured vulnerability curves (VCs: percentage loss hydraulic conductivity versus tension) in aspen stems and measured vessel-size distributions. Measurements were done on seed-grown, 4-month-old aspen (Populus tremuloides Michx) grown in a greenhouse. VCs of stem segments were measured using a centrifuge technique and by a staining technique that allowed a VC to be constructed based on vessel diameter size-classes (D). Vessel-based VCs were also fitted to Weibull cumulative distribution functions (CDF), which provided best-fit values of Weibull CDF constants (c and b) and P(50) = the tension causing 50% loss of hydraulic conductivity. We show that P(50) = 6.166D(-0.3134) (R(2) = 0.995) and that b and 1/c are both linear functions of D with R(2) > 0.95. The results are discussed in terms of models of VCs based on vessel D size-classes and in terms of concepts such as the 'pit area hypothesis' and vessel pathway redundancy.

  5. Nuclear analysis and shielding optimisation in support of the ITER In-Vessel Viewing System design

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Andrew, E-mail: andrew.turner@ccfe.ac.uk [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Pampin, Raul [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Loughlin, M.J. [ITER Organisation, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Ghani, Zamir; Hurst, Gemma [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Lo Bue, Alessandro [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Mangham, Samuel [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Puiu, Adrian [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Zheng, Shanliang [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)

    2014-10-15

    The In-Vessel Viewing System (IVVS) units proposed for ITER are deployed to perform in-vessel examination. During plasma operations, the IVVS is located beyond the vacuum vessel, with shielding blocks envisaged to protect components from neutron damage and reduce shutdown dose rate (SDR) levels. Analyses were conducted to determine the effectiveness of several shielding configurations. The neutron response of the system was assessed using global variance reduction techniques and a surface source, and shutdown dose rate calculations were undertaken using MCR2S. Unshielded, the absorbed dose to piezoelectric motors (PZT) was found to be below stable limits, however activation of the primary closure plate (PCP) was prohibitively high. A scenario with shielding blocks at probe level showed significantly reduced PCP contact dose rate, however still marginally exceeded port cell requirements. The addition of shielding blocks at the bioshield plug demonstrated PCP contact dose rates below project requirements. SDR levels in contact with the isolated IVVS cartridge were found to marginally exceed the hands-on maintenance limit. For engineering feasibility, shielding blocks at bioshield level are to be avoided, however the port cell SDR field requires further consideration. In addition, alternative low-activation steels are being considered for the IVVS cartridge.

  6. Fabrication Flaw Density and Distribution In Repairs to Reactor Pressure Vessel and Piping Welds

    Energy Technology Data Exchange (ETDEWEB)

    GJ Schuster, FA Simonen, SR Doctor

    2008-04-01

    The Pacific Northwest National Laboratory is developing a generalized fabrication flaw distribution for the population of nuclear reactor pressure vessels and for piping welds in U.S. operating reactors. The purpose of the generalized flaw distribution is to predict component-specific flaw densities. The estimates of fabrication flaws are intended for use in fracture mechanics structural integrity assessments. Structural integrity assessments, such as estimating the frequency of loss-of-coolant accidents, are performed by computer codes that require, as input, accurate estimates of flaw densities. Welds from four different reactor pressure vessels and a collection of archived pipes have been studied to develop empirical estimates of fabrication flaw densities. This report describes the fabrication flaw distribution and characterization in the repair weld metal of vessels and piping. This work indicates that large flaws occur in these repairs. These results show that repair flaws are complex in composition and sometimes include cracks on the ends of the repair cavities. Parametric analysis using an exponential fit is performed on the data. The relevance of construction records is established for describing fabrication processes and product forms. An analysis of these records shows there was a significant change in repair frequency over the years when these components were fabricated. A description of repair flaw morphology is provided with a discussion of fracture mechanics significance. Fabrication flaws in repairs are characterized using optimized-access, high-sensitivity nondestructive ultrasonic testing. Flaw characterizations are then validated by other nondestructive evaluation techniques and complemented by destructive testing.

  7. High frequency ultrasound in-plane registration of deformable finger vessels

    Science.gov (United States)

    Che, Chengqian; Wang, Jihang; Gorantla, Vijay S.; Galeotti, John

    2017-02-01

    Ultrasound imaging is widely used in clinical imaging because it is non-invasive, real-time, and inexpensive. Due to the freehand nature of clinical ultrasound, analysis of an image sequence often requires registration between the images. Of the previously developed mono-modality ultrasound registration frameworks, only few were designed to register small anatomical structures. Monitoring of small finger vessels, in particular, is essential for the treatment of vascular diseases such as Raynaud's Disease. High frequency ultrasound (HFUS) can now image smaller anatomic details down to 30 microns within the vessels, but no work has been done to date on such small-scale ultrasound registration. Due to the complex internal finger structure and increased noise of HFUS, it is difficult to register 2D images of finger vascular tissue, especially under deformation. We studied a variety of similarity measurements with different pre-processing techniques to find which registration similarity metrics were best suited for HFUS vessel tracking. The overall best performance was obtained with a normalized correlation metric coupled with HFUS downsampling and a one-plus-one evolutionary optimizer, yielding a mean registration error of 0.05 mm. We also used HFUS to study how finger tissue deforms under an ultrasound transducer, comparing internal motion vs. transducer motion. Improving HFUS registration and tissue modeling may lead to new research and improved treatments for peripheral vascular disorders.

  8. Correlation between radiation damage and magnetic properties in reactor vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Kempf, R.A., E-mail: kempf@cnea.gov.ar [División Caracterización, GCCN, CAC-CNEA (Argentina); Sacanell, J. [Departamento Física de la Materia Condensada, GIyA, CAC-CNEA, CONICET (Argentina); Milano, J. [División Resonancias Magnéticas, CAB-CNEA, CONICET (Argentina); Guerra Méndez, N. [Departamento Física de la Materia Condensada, GIyA, CAC-CNEA, CONICET (Argentina); Winkler, E.; Butera, A. [División Resonancias Magnéticas, CAB-CNEA, CONICET (Argentina); Troiani, H. [División Física de Metales, CAB-CNEA and Instituto Balseiro (UNCU), CONICET (Argentina); Saleta, M.E. [División Resonancias Magnéticas, CAB-CNEA, CONICET (Argentina); Fortis, A.M. [Departamento Estructura y Comportamiento. Gerencia Materiales-GAEN, CAC-CNEA (Argentina)

    2014-02-01

    Since reactor pressure vessel steels are ferromagnetic, provide a convenient means to monitor changes in the mechanical properties of the material upon irradiation with high energy particles, by measuring their magnetic properties. Here, we discuss the correlation between mechanical and magnetic properties and microstructure, by studying the flux effect on the nuclear pressure vessel steel used in reactors currently under construction in Argentina. Charpy-V notched specimens of this steel were irradiated in the RA1 experimental reactor at 275 °C with two lead factors (LFs), 93 and 183. The magnetic properties were studied by means of DC magnetometry and ferromagnetic resonance. The results show that the coercive field and magnetic anisotropy spatial distribution are sensitive to the LF and can be explained by taking into account the evolution of the microstructure with this parameter. The saturation magnetization shows a dominant dependence on the accumulated damage. Consequently, the mentioned techniques are suitable to estimate the degradation of the reactor vessel steel.

  9. Breast Contrast Enhanced MR Imaging: Semi-Automatic Detection of Vascular Map and Predominant Feeding Vessel.

    Science.gov (United States)

    Petrillo, Antonella; Fusco, Roberta; Filice, Salvatore; Granata, Vincenza; Catalano, Orlando; Vallone, Paolo; Di Bonito, Maurizio; D'Aiuto, Massimiliano; Rinaldo, Massimo; Capasso, Immacolata; Sansone, Mario

    2016-01-01

    To obtain breast vascular map and to assess correlation between predominant feeding vessel and tumor location with a semi-automatic method compared to conventional radiologic reading. 148 malignant and 75 benign breast lesions were included. All patients underwent bilateral MR imaging. Written informed consent was obtained from the patients before MRI. The local ethics committee granted approval for this study. Semi-automatic breast vascular map and predominant vessel detection was performed on MRI, for each patient. Semi-automatic detection (depending on grey levels threshold manually chosen by radiologist) was compared with results of two expert radiologists; inter-observer variability and reliability of semi-automatic approach were assessed. Anatomic analysis of breast lesions revealed that 20% of patients had masses in internal half, 50% in external half and the 30% in subareolar/central area. As regards the 44 tumors in internal half, based on radiologic consensus, 40 demonstrated a predominant feeding vessel (61% were supplied by internal thoracic vessels, 14% by lateral thoracic vessels, 16% by both thoracic vessels and 9% had no predominant feeding vessel-pfeeding vessel (66% were supplied by internal thoracic vessels, 11% by lateral thoracic vessels, 9% by both thoracic vessels and 14% had no predominant feeding vessel-pfeeding vessel (25% were supplied by internal thoracic vessels, 39% by lateral thoracic vessels, 18% by both thoracic vessels and 18% had no predominant feeding vessel-pfeeding vessel (27% were supplied by internal thoracic vessels, 45% by lateral thoracic vessels, 4% by both thoracic vessels and 24% had no predominant feeding vessel-pfeeding vessel. An excellent reliability for semi-automatic assessment (Cronbach's alpha = 0.96) was reported. Predominant feeding vessel location was correlated with breast lesion location: internal thoracic artery supplied the highest proportion of breasts with tumor in internal half and lateral thoracic

  10. Segmentation of retinal blood vessels using normalized Gabor filters and automatic thresholding

    Directory of Open Access Journals (Sweden)

    Mandlenkosi Victor Gwetu

    2014-12-01

    Full Text Available Although computerized retinal image blood vessel segmentation has been extensively researched, there is still room for improvement in the quality of the segmented images. Since retinal image analysis is still widely used in the diagnosis of diabetic retinopathy, efficient and accurate image characterization techniques are required. Previous work has mainly focused on improving segmentation accuracy rates with little regard to the false positives that are produced by illumination variation. This research work presents a hybrid approach towards the segmentation of retinal blood vessels. New approaches towards the reduction of background illumination variation are proposed using normalized Gabor filtering. These are the base-offset encoding and a modified version of an existing zero-integral kernel technique. The valley emphasis automatic thresholding scheme is used to segment the Gabor response images. Experiments are conducted on the DRIVE and STARE retinal image data sets. Accuracy rates of up to 94% are achieved through the zero-integral and base offset methods. This is comparable with results from literature, where the same data sets are segmented using other classification techniques. The median-offset method is found to most effectively reduce background illumination variation.

  11. Finding an optimal method for imaging lymphatic vessels of the upper limb

    Energy Technology Data Exchange (ETDEWEB)

    O' Mahony, Susan; Purushotham, Arnie D. [Cambridge Breast Unit, Addenbrooke' s Hospital, Cambridge (United Kingdom); Rose, Sarah L.; Chilvers, Alison J.; Ballinger, James R.; Solanki, Chandra K.; Barber, Robert W.; Peters, A. Michael [Department of Nuclear Medicine, Addenbrooke' s Hospital, Hills Road, CB2 2QQ, Cambridge (United Kingdom); Mortimer, Peter S. [Department of Medicine, St George' s Hospital, London (United Kingdom)

    2004-04-01

    Lymphoscintigraphy involves interstitial injection of radiolabelled particulate materials or radioproteins. Although several variations in the technique have been described, their place in clinical practice remains controversial. Traditional diagnostic criteria are based primarily on lymph node appearances but in situations such as breast cancer, where lymph nodes may have been excised, these criteria are of limited use. In these circumstances, lymphatic vessel morphology takes on greater importance as a clinical endpoint, so a method that gives good definition of lymphatic vessels would be useful. In patients with breast cancer, for example, such a method, used before and after lymph node resection, may assist in predicting the development of breast cancer-related lymphoedema. The aim of this study was to optimise a method for the visualisation of lymphatic vessels. Subcutaneous (sc) and intradermal (id) injection sites were compared, and technetium-99m nanocolloid, a particulate material, was compared with {sup 99m}Tc-human immunoglobulin (HIG), which is a soluble macromolecule. Twelve normal volunteers were each studied on two occasions. In three subjects, id {sup 99m}Tc-HIG was compared with sc {sup 99m}Tc-HIG, in three id {sup 99m}Tc-nanocolloid was compared with sc {sup 99m}Tc-nanocolloid, in three id {sup 99m}Tc-HIG was compared with id {sup 99m}Tc-nanocolloid and in three sc {sup 99m}Tc-HIG was compared with sc {sup 99m}Tc-nanocolloid. Endpoints were quality of lymphatic vessel definition, the time after injection at which vessels were most clearly visualised, the rate constant of depot disappearance (k) and the systemic blood accumulation rate as measured by gamma camera imaging over the liver or cardiac blood pool. Excellent definition of lymphatic vessels was obtained following id injection of either radiopharmaceutical, an injection route that was clearly superior to sc. Differences between radiopharmaceuticals were less clear, although after id

  12. Study of evaluation methods for in-vessel corium retention through external vessel cooling and safety of reactor cavity

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Hoon; Chang, Soon Heung; Kim, Soo Hyung; Kim, Kee Poong; Lee, Hyoung Wook; Jang, Kwang Keol; Jeong, Yong Hoon; Kim, Sang Jin; Lee, Seong Jin [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Park, Jae Hong [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    2001-03-15

    In this work, assessment system for methodology for reactor pressure vessel integrity is developed. Assessment system is make up of severe accident assessment code which can calculate the conditions of plant and structural analysis code which can assess the integrity of reactor vessel using given plant conditions. An assessment of cavity flooding using containment spray system has been done. As a result, by the containment spray, cavity can be flooded successfully and CCI can be reduced. The technical backgrounds for external vessel cooling and corium cooling on the cavity are summarized and provided in this report.

  13. Remote through-wall sampling of the Trawsfynydd reactor pressure vessel: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Curry, A.; Clayton, R. [Magnox Electric, Berkeley (United Kingdom)

    1997-02-01

    This paper summarizes the application of robotic equipment for gaining access to, and removing through-wall samples, from, welds of the reactor pressure vessel at Trawsfyndd power station. The environment, which presents hazards due to ionising radiation, radioactive contamination and asbestos-bearing materials is described. The means of access, by use of remote vehicles with robotic manipulators supported by additional vehicles, it reviewed. The use of abrasive water jet cutting for sample removal is introduced. The relative advantages and disadvantages of this technique are discussed. (Author).

  14. Remote through-wall sampling of the Trawsfynydd reactor pressure vessel: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Curry, A.; Clayton, R. [Magnox Electric, Dartford (United Kingdom). Remote Operations

    1996-12-31

    This paper summarises the application of robotic equipment for gaining access to and removing through-wall samples from welds of the reactor pressure vessel at Trawsfynydd power station. The environment, which presents hazards due to ionising radiation, radioactive contamination and asbestos bearing materials is described. The means of access, by use of remote vehicles complete with robotic manipulators supported by additional vehicles, is reviewed. The use of Abrasive Water Jet Cutting for sample removal is introduced. The relative advantages and disadvantages of this technique are discussed. (UK).

  15. Elliptical Local Vessel Density: a Fast and Robust Quality Metric for Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Chaum, Edward [ORNL; Karnowski, Thomas Paul [ORNL; Meriaudeau, Fabrice [ORNL; Tobin Jr, Kenneth William [ORNL; Abramoff, M.D. [University of Iowa

    2008-01-01

    A great effort of the research community is geared towards the creation of an automatic screening system able to promptly detect diabetic retinopathy with the use of fundus cameras. In addition, there are some documented approaches to the problem of automatically judging the image quality. We propose a new set of features independent of Field of View or resolution to describe the morphology of the patient's vessels. Our initial results suggest that they can be used to estimate the image quality in a time one order of magnitude shorter respect to previous techniques.

  16. Expert system for determining welding condition for a pressure vessel

    National Research Council Canada - National Science Library

    Fukuda, Shuichi; Morita, Hideki; Yamauchi, Yoshihisa; Nagasawa, Isao; Tsuji, Shuichi

    1990-01-01

    This paper describes the outline of the expert system for producing a Welding Procedure Specification for a pressure vessel which was developed with the grant from the Ministry of International Trade...

  17. Great Lakes Research Vessel Operations 1958-2016: Trawl

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — All trawl data represented here expand upon vessel operations (OP table) data, all of which are collected by the United States Geological Survey, Great Lakes Science...

  18. A model for ultrasound contrast agent in a phantom vessel

    KAUST Repository

    Qamar, Adnan

    2014-02-01

    A theoretical framework to model the dynamics of Ultrasound Contrast Agent (UCA) inside a phantom vessel is presented. The model is derived from the reduced Navier-Stokes equation and is coupled with the evolving flow field solution inside the vessel by a similarity transformation approach. The results are computed, and compared with experiments available in literature, for the initial UCA radius of Ro=1.5 μm and 2 μm for the vessel diameter of D=12 μm and 200 μm with the acoustic parameters as utilized in the experiments. When compared to other models, better agreement on smaller vessel diameter is obtained with the proposed coupled model. The model also predicts, quite accurately, bubble fragmentation in terms of acoustic and geometric parameters. © 2014 IEEE.

  19. Great Lakes Research Vessel Operations 1958-2016: Mysis

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — All mysis data represented here expand upon vessel operations (OP table) data, all of which are collected by the United States Geological Survey, Great Lakes Science...

  20. 76 FR 18132 - Interest on Untimely Paid Vessel Repair Duties

    Science.gov (United States)

    2011-04-01

    ..., Reporting and recordkeeping requirements, Shipping, Vessels. 19 CFR Part 24 Accounting, Claims, Customs... ``will''; and m. In paragraph (c)(1), by removing the words ``CBP Office of Finance, Indianapolis...

  1. Great Lakes Research Vessel Operations 1958-2016: Mensuration

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — All mensuration data represented here expand upon vessel operations (OP table) data, all of which are collected by the United States Geological Survey, Great Lakes...

  2. Light-induced bird strikes on vessels in Southwest Greenland

    DEFF Research Database (Denmark)

    Merkel, Flemming Ravn; Johansen, Kasper Lambert

    2011-01-01

    Light-induced bird strikes are known to occur when vessels navigate during darkness in icy waters using powerful searchlight. In Southwest Greenland, which is important internationally for wintering seabirds, we collected reports of incidents of bird strikes over 2–3 winters (2006–2009) from navy...... vessels, cargo vessels and trawlers (total n = 19). Forty-one incidents were reported: mainly close to land (birds were reported killed in a single incident. All occurred between 5 p.m. and 6 a.m. and significantly more birds were involved when...... visibility was poor (snow) rather than moderate or good. Among five seabird species reported, the common eider (Somateria mollissima) accounted for 95% of the bird casualties. Based on spatial analyses of data on vessel traffic intensity and common eider density we are able to predict areas with high risk...

  3. Great Lakes Research Vessel Operations 1958-2016: Gillnet

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — All gillnet data represented here expand upon vessel operations (OP table) data, all of which are collected by the United States Geological Survey, Great Lakes...

  4. Great Lakes Research Vessel Operations 1958-2016: Reference

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The RVCAT database contains data that have been collected on various vessel operations on the Great Lakes and select connecting waterways. This section of Reference...

  5. Gulf of Mexico Marine Mammal Assessment Vessel Surveys

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data sets are a compilation of large vessel surveys for marine mammal stock assessments in the Gulf of Mexico from 1991 to the present. These are designed as...

  6. AFSC/NMML: Southeast Alaska Cetacean Vessel Surveys, 1991 - 2012

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — In 1991, NMML initiated cetacean studies with vessel coverage throughout inland waters of Southeast Alaska. Between 1991 and 1993, line-transect methodology was used...

  7. Solitonlike attractor for blood vessel tip density in angiogenesis

    Science.gov (United States)

    Bonilla, L. L.; Carretero, M.; Terragni, F.

    2016-12-01

    Recently, numerical simulations of a stochastic model have shown that the density of vessel tips in tumor-induced angiogenesis adopts a solitonlike profile [Sci. Rep. 6, 31296 (2016), 10.1038/srep31296]. In this work, we derive and solve the equations for the soliton collective coordinates that indicate how the soliton adapts its shape and velocity to varying chemotaxis and diffusion. The vessel tip density can be reconstructed from the soliton formulas. While the stochastic model exhibits large fluctuations, we show that the location of the maximum vessel tip density for different replicas follows closely the soliton peak position calculated either by ensemble averages or by solving an alternative deterministic description of the density. The simple soliton collective coordinate equations may also be used to ascertain the response of the vessel network to changes in the parameters and thus to control it.

  8. Caribbean ST Thomas all gears Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels fishing in St. Thomas. The catch and effort data for the entire trip are...

  9. ISO and EIGA standards for cryogenic vessels and accessories

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The EIGA/WG 6’s scope is cryogenic vessels and accessories, including their design, material compatibility, operational requirements and periodical inspection. The specific responsibilities include monitoring international standardization (ISO, CEN) and regulations (UN, TPED, PED...

  10. AKRO/SF: Vessel (at-sea) Production Reports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Vessel (at-sea) production reports are mandatory reports submitted by catcher/processors and motherships that are issued a Federal Fishing Permit. These reports...

  11. Great Lakes Research Vessel Operations 1958-2016: Benthos Ponar

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — All benthos data represented here expand upon vessel operations (OP table) data, all of which are collected by the United States Geological Survey, Great Lakes...

  12. Firefighter's compressed air breathing system pressure vessel development program

    Science.gov (United States)

    Beck, E. J.

    1974-01-01

    The research to design, fabricate, test, and deliver a pressure vessel for the main component in an improved high-performance firefighter's breathing system is reported. The principal physical and performance characteristics of the vessel which were required are: (1) maximum weight of 9.0 lb; (2) maximum operating pressure of 4500 psig (charge pressure of 4000 psig); (3) minimum contained volume of 280 in. 3; (4) proof pressure of 6750 psig; (5) minimum burst pressure of 9000 psig following operational and service life; and (6) a minimum service life of 15 years. The vessel developed to fulfill the requirements described was completely sucessful, i.e., every category of performence was satisfied. The average weight of the vessel was found to be about 8.3 lb, well below the 9.0 lb specification requirement.

  13. Development of an integrated data acquision system for research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Mehra, P.; Desai, R.G.P.

    This article describes an integrated data acquisition system (IDAS) designed and developed for multi-oceanographic research vessels. The prime motivation was to provide a flexible system, which could be used in the context of ocean related...

  14. Aging changes in the heart and blood vessels

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/004006.htm Aging changes in the heart and blood vessels To use ... the heart. Watch this video about: Blood flow AGING CHANGES Heart: The heart has a natural pacemaker system ...

  15. Randomized comparison of coronary bifurcation stenting with the crush versus the culotte technique using sirolimus eluting stents: the Nordic stent technique study

    DEFF Research Database (Denmark)

    Erglis, Andrejs; Kumsars, Indulis; Niemelä, Matti

    2009-01-01

    BACKGROUND: In a number of coronary bifurcation lesions, both the main vessel and the side branch need stent coverage. Using sirolimus eluting stents, we compared 2 dedicated bifurcation stent techniques, the crush and the culotte techniques in a randomized trial with separate clinical and angiog......BACKGROUND: In a number of coronary bifurcation lesions, both the main vessel and the side branch need stent coverage. Using sirolimus eluting stents, we compared 2 dedicated bifurcation stent techniques, the crush and the culotte techniques in a randomized trial with separate clinical...

  16. Surveillance Techniques for the Vessel Traffic Service Systems of the U. S. Coast Guard

    Science.gov (United States)

    1990-06-01

    Inf’orniation Processing Stundards (F! PS). These include: e POSIX (FIPS 151). Portable Opcratin; System lnterflacc flor Computer Environ- ment. *fhis standard...GUARD V’TS SUTR VEIL LA NC’E A. ASSUMPTIONS FOR TECHNOLOGY SELECTION * During the author’s interviews and research, several themes ran through the opin...reduction in required mani-ower, rental cost% ( flor leased s’ stems), or maintenance costs (ror USCO owned systems) are theref’ore key elements inl

  17. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    Energy Technology Data Exchange (ETDEWEB)

    Ruparelia, Neil [San Raffaele Scientific Institute, Milan (Italy); Imperial College, London (United Kingdom); Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio [San Raffaele Scientific Institute, Milan (Italy); Latib, Azeem, E-mail: info@emocolumbus.it [San Raffaele Scientific Institute, Milan (Italy)

    2015-09-15

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  18. Does sample length influence the shape of xylem embolism vulnerability curves? A test with the Cavitron spinning technique.

    Science.gov (United States)

    Cochard, Hervé; Herbette, Stéphane; Barigah, Têtè; Badel, Eric; Ennajeh, Mustapha; Vilagrosa, Alberto

    2010-09-01

    The Cavitron spinning technique is used to construct xylem embolism vulnerability curves (VCs), but its reliability has been questioned for species with long vessels. This technique generates two types of VC: sigmoid 's'-shaped and exponential, levelling-off 'r'-shaped curves. We tested the hypothesis that 'r'-shaped VCs were anomalous and caused by the presence of vessels cut open during sample preparation. A Cavitron apparatus was used to construct VCs from samples of different lengths in species with contrasting vessel lengths. The results were compared with VCs obtained using other independent techniques. When vessel length exceeded sample length, VCs were 'r'-shaped and anomalous. Filling vessels cut open at both ends with air before measurement produced more typical 's'-shaped VCs. We also found that exposing segments of 11 woody species in a Cavitron at the pressure measured in planta before sampling considerably increased the degree of embolism above the native state level for species with long vessels. We concluded that open vessels were abnormally more vulnerable to cavitation than intact vessels. We recommend restricting this technique to species with short conduits. The relevance of our conclusions for other spinning techniques is discussed.

  19. Identification of periodontal pathogens in atherosclerotic vessels

    DEFF Research Database (Denmark)

    Fiehn, Nils-Erik; Larsen, Tove; Christiansen, Natalia

    2005-01-01

    Epidemiological studies have shown that periodontitis may be associated with presence of atherosclerosis. DNA from periodontal pathogens has been detected in atherosclerotic lesions, but viable oral bacteria have not yet been isolated from atherosclerotic plaques. The purpose of the present study...... was to determine if viable oral bacteria could be isolated from atherosclerotic lesions and if DNA from periodontal pathogens could be detected by use of polymerase chain reaction (PCR) techniques....

  20. Postchemotherapy laparoscopic retroperitoneal lymph node dissection for nonseminomatous germ cell tumors infiltrating the great vessels.

    Science.gov (United States)

    Aufderklamm, Stefan; Todenhöfer, Tilman; Hennenlotter, Joerg; Mischinger, Johannes; Böttge, Johannes; Rausch, Steffen; Halalsheh, Omar; Stenzl, Arnulf; Gakis, Georgios; Schwentner, Christian

    2014-06-01

    Laparoscopic retroperitoneal lymph node dissection (L-RPLND) is an alternative in patients with metastatic nonseminomatous germcell tumors (NSGCT) necessitating resection of residuals postchemotherapy. With the advancement of laparoscopic vascular surgery, prospective management of the great vessels has become feasible and safe. We present our experience with L-RPLND in NSGCT residuals with significant vascular involvement necessitating intracorporeal reconstruction. We have retrospectively identified 19 NSGCT patients (mean age 27 years) who presented with residuals postchemotherapy. A bilateral L-RPLND was performed in all men. Infiltration of the great vessels was confirmed intraoperatively. Prospective vascular control and temporary clamping was performed in all cases. The vessel wall was reconstructed using vascular surgery techniques. All patients had at least clinical stages of IIA or higher. Follow-up was obtained in all. There were no conversions to open surgery. The mean size of the residuals after chemotherapy was 3.87 cm (1.5-9.7 cm). The mean blood loss was 310 mL (50-1000 mL). Mean hospital stay was 6 days (3-9 days). There were no perioperative complications exceeding grade II according to the Clavien-Dindo classification. Distant or in-field recurrence (mean observational period 18 months) did not develop in any patient. Laparoscopic RPLND may be considered a safe alternative concept for the management of post-chemotherapy NSGCT residuals involving the great vessels. Bilateral L-RPLND in patients with vascular infiltration is feasible and reproducible when laparoscopic vascular surgery can be reliably handled. All standard principles of open surgery are respected, and initial oncologic results are promising.

  1. Terahertz Techniques

    CERN Document Server

    Bründermann, Erik; Kimmitt, Maurice FitzGerald

    2012-01-01

    Research and development in the terahertz portion of the electromagnetic spectrum has expanded very rapidly during the past fifteen years due to major advances in sources, detectors and instrumentation. Many scientists and engineers are entering the field and this volume offers a comprehensive and integrated treatment of all aspects of terahertz technology. The three authors, who have been active researchers in this region over a number of years, have designed Terahertz Techniques to be both a general introduction to the subject and a definitive reference resource for all those involved in this exciting research area.

  2. Analysis and Visualization of Nerve Vessel Contacts for Neurovascular Decompression

    Science.gov (United States)

    Süßmuth, Jochen; Piazza, Alexander; Enders, Frank; Naraghi, Ramin; Greiner, Günther; Hastreiter, Peter

    Neurovascular compression syndromes are caused by a pathological contact between cranial nerves and vascular structures at the surface of the brainstem. Aiming at improved pre-operative analysis of the target structures, we propose calculating distance fields to provide quantitative information of the important nerve-vessel contacts. Furthermore, we suggest reconstructing polygonal models for the nerves and vessels. Color-coding with the respective distance information is used for enhanced visualization. Overall, our new strategy contributes to a significantly improved clinical understanding.

  3. Three - dimensional magnetic field observation vessel using magnetic fluid

    OpenAIRE

    櫻井, 勇良

    2011-01-01

    In this study, an observation vessel which could depict magnetic field distributions in threedimensionswas produced. The magnetic field observation vessel was made by putting magnetic fluid and water in a transparent square shaped glass container. Observation of both permanent magnet andelectromagnets was carried out. The movement of the magnetic fluid is different depending on the placement of the magnetic poles. The magnetic fluid showed a tendency to gather near each magnetic pole, when it...

  4. Distribution of the lymphatic vessels in the prostatic fascia.

    Science.gov (United States)

    Soga, Hideo; Takenaka, Atsushi; Murakami, Gen; Haraguchi, Takahiro; Miyake, Hideaki; Tanaka, Kazushi; Fujisawa, Masato

    2011-09-01

    The prostatic fascia-preserving procedure is effective for the early recovery of erectile function after radical prostatectomy; however, the long-term influence of on cancer control was unknown. This study clarified the distribution of lymphatic vessels in the prostatic fascia. The lymphatic vessels were analyzed in 10 prostates obtained from fixed Japanese cadavers (aged, 71-90 years old). Specimens were taken from the apex, the middle part, and the base of the right-hand side of the prostate. Lymphatic vessels were detected by immunohistochemical stain using an antibody specific for the lymphatic endothelial cells (clone D2-40). The lymphatic vessels were counted in the prostate capsule and the prostatic fascia of each section by light microscopy at low power (100×). The median number of lymphatic vessels in the prostatic capsule per prostatic half was 21.0, 14.0, and 21.0 in the apex, middle, and base part of the prostate, respectively. In the prostatic facia the median number of lymphatic vessels per prostatic half was 8.0, 3.0, and 13.0 in the apex, middle, and the base part of the prostate, respectively. In the apex and the middle part the lymphatic vessels in the prostatic fascia were fewer than those in the prostatic capsule. However, in the base part the number of lymphatic vessels in the prostatic fascia was similar to that in the prostatic capsule. The present study suggested the surgeon to pay more attention for the dissection of the fascia at the base of the prostate. Copyright © 2011 Wiley-Liss, Inc.

  5. Structural design for a 10-GWh SMES vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, J.G.; Anderson, C.A.

    1978-01-01

    An approximate solution to the problem of the nonlinear elastic deformation of a periodically point-supported cylindrical shell is obtained. This solution is used to investigate the structural design of the vacuum vessel for the large underground superconducting magnetic energy storage (SMES) concept. Vacuum vessel designs are evaluated by varying such parameters as shell thickness, support spacing, material properties and physical configuration to keep the amount of material used and construction cost to a minimum.

  6. On-line monitoring and analysis of reactor vessel integrity

    Energy Technology Data Exchange (ETDEWEB)

    Ackerson, D.S.; Impink, A.J. Jr.; Balkey, K.R.; Andreychek, T.S.

    1989-01-31

    A method is described for on-line monitoring and analysis of nuclear reactor pressure vessel integrity in a unit in which reactor coolant is circulated along the inner wall of the pressure vessel, the method comprising the steps of: generating on an on-line basis, temperature signals representative of the temperature of the reactor coolant circulating along the inner wall of the pressure vessel; generating on an on-line basis, a pressure signal representative of the reactor coolant pressure; generating a signal representative of fast neutron fluence to which the reactor pressure vessel has been subjected; generating as a function of the fluence signal a visual representation of the actual real time reference nil-ductibility transition temperature (RT/sub ndt/) across the entire pressure vessel wall thickness at a preselected critical location in the wall; generating as a function of transients in the reactor coolant temperature and pressur signals, a visual representation of the real time required RT/sub ndt/, across the entire pressure vessel wall thickness at the selected critical location, the required RT/sub ndt/ being the RT/sub ndt/ that would be required in the pressure vessel wall for flaw initiation to occur as a result of stresses set-up by the transients; and superimposing the visual representations of the real-time actual and required RT/sub ndt's/ for flaw initiation across the entire pressure vessel wall thickness for the selected critical location to generate a visual representation of the difference in value between the actual and required RT/sub ndt/ presented as an RT/sub ndt/ margin.

  7. Using SA508/533 for the HTGR Vessel Material

    Energy Technology Data Exchange (ETDEWEB)

    Larry Demick

    2012-06-01

    This paper examines the influence of High Temperature Gas-cooled Reactor (HTGR) module power rating and normal operating temperatures on the use of SA508/533 material for the HTGR vessel system with emphasis on the calculated times at elevated temperatures approaching or exceeding ASME Code Service Limits (Levels B&C) to which the reactor pressure vessel could be exposed during postulated pressurized and depressurized conduction cooldown events over its design lifetime.

  8. Semi-automated retinal vessel analysis in nonmydriatic fundus photography.

    Science.gov (United States)

    Schuster, Alexander Karl-Georg; Fischer, Joachim Ernst; Vossmerbaeumer, Urs

    2014-02-01

    Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial-venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the results were ascertained using nonmydriatic photographs of 50 eyes from 25 subjects recorded from a 3DOCT device (Topcon Corp.). Two hundred and thirty-three eyes of 121 healthy subjects were evaluated to define normative values. A software tool was developed using image thresholds for vessel recognition and vessel width calculation in a semi-automated three-step procedure: vessel recognition on the photograph and artery/vein designation, width measurement and calculation of central retinal vessel equivalents. Mean vessel recognition rate was 78%, vessel class designation rate 75% and reproducibility between 0.78 and 0.91. Mean A/V ratio was 0.84. Application on a healthy norm cohort showed high congruence with prior published manual methods. Processing time per image was one minute. Quantitative geometrical assessment of the retinal vasculature may be performed in a semi-automated manner using dedicated software tools. Yielding reproducible numerical data within a short time leap, this may contribute additional value to mere morphological estimates in the clinical evaluation of fundus photographs. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Bladder injury by penetration of artificial vessel graft

    OpenAIRE

    和田, 直樹; 玉木, 岳; 倉, 達彦; 佐賀, 祐司; 柿崎, 秀宏

    2009-01-01

    Iatrogenic bladder injury by artificial vessel graft is extremely rare and only 3 cases have been reported. Herein, we report a case of bladder injury by penetration of artificial vessel graft. An 80-year-old male underwent a femoro-femoral crossover bypass surgery for arteriosclerosis obliterans in our hospital. Postoperatively he complained of urinary incontinence and was referred to the urology department. Ultrasonography for evaluating microscopic hematuria revealed a high echoic linear s...

  10. The impact of vessel speed reduction on port accidents.

    Science.gov (United States)

    Chang, Young-Tae; Park, Hyosoo

    2016-03-19

    Reduced-speed zones (RSZs) have been designated across the world to control emissions from ships and prevent mammal strikes. While some studies have examined the effectiveness of speed reduction on emissions and mammal preservation, few have analyzed the effects of reduced ship speed on vessel safety. Those few studies have not yet measured the relationship between vessel speed and accidents by using real accident data. To fill this gap in the literature, this study estimates the impact of vessel speed reduction on vessel damages, casualties and frequency of vessel accidents. Accidents in RSZ ports were compared to non-RSZ ports by using U.S. Coast Guard data to capture the speed reduction effects. The results show that speed reduction influenced accident frequency as a result of two factors, the fuel price and the RSZ designation. Every $10 increase in the fuel price led to a 10.3% decrease in the number of accidents, and the RSZ designation reduced vessel accidents by 47.9%. However, the results do not clarify the exact impact of speed reduction on accident casualty. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Robust hepatic vessel segmentation using multi deep convolution network

    Science.gov (United States)

    Kitrungrotsakul, Titinunt; Han, Xian-Hua; Iwamoto, Yutaro; Foruzan, Amir Hossein; Lin, Lanfen; Chen, Yen-Wei

    2017-03-01

    Extraction of blood vessels of the organ is a challenging task in the area of medical image processing. It is really difficult to get accurate vessel segmentation results even with manually labeling by human being. The difficulty of vessels segmentation is the complicated structure of blood vessels and its large variations that make them hard to recognize. In this paper, we present deep artificial neural network architecture to automatically segment the hepatic vessels from computed tomography (CT) image. We proposed novel deep neural network (DNN) architecture for vessel segmentation from a medical CT volume, which consists of three deep convolution neural networks to extract features from difference planes of CT data. The three networks have share features at the first convolution layer but will separately learn their own features in the second layer. All three networks will join again at the top layer. To validate effectiveness and efficiency of our proposed method, we conduct experiments on 12 CT volumes which training data are randomly generate from 5 CT volumes and 7 using for test. Our network can yield an average dice coefficient 0.830, while 3D deep convolution neural network can yield around 0.7 and multi-scale can yield only 0.6.

  12. Novel Method for Vessel Cross-Sectional Shear Wave Imaging.

    Science.gov (United States)

    He, Qiong; Li, Guo-Yang; Lee, Fu-Feng; Zhang, Qihao; Cao, Yanping; Luo, Jianwen

    2017-07-01

    Many studies have investigated the applications of shear wave imaging (SWI) to vascular elastography, mainly on the longitudinal section of vessels. It is important to investigate SWI in the arterial cross section when evaluating anisotropy of the vessel wall or complete plaque composition. Here, we proposed a novel method based on the coordinate transformation and directional filter in the polar coordinate system to achieve vessel cross-sectional shear wave imaging. In particular, ultrasound radiofrequency data were transformed from the Cartesian to the polar coordinate system; the radial displacements were then estimated directly. Directional filtering was performed along the circumferential direction to filter out the reflected waves. The feasibility of the proposed vessel cross-sectional shear wave imaging method was investigated through phantom experiments and ex vivo and in vivo studies. Our results indicated that the dispersion relation of the shear wave (i.e., the guided circumferential wave) within the vessel can be measured via the present method, and the elastic modulus of the vessel can be determined. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Color doppler in diagnosis of pathological changes in blood vessels

    Directory of Open Access Journals (Sweden)

    Mladenović Saša

    2014-01-01

    Full Text Available Color Doppler ultrasound is a method that allows noninvasive imaging of blood flow through a blood vessel and analysis of blood vessels, which can be made to flow disturbance and the presence of plaque and narrowing of the blood vessel. Color Doppler ultrasonography allows early detection of pathological changes in blood vessels, which contributes to adequate preventive and therapeutic procedures in the prevention of cerebrovascular disorders. The aim of this paper is to demonstrate the importance of color Doppler ultrasound blood vessels in the diagnosis of pathological changes in the blood vessels of the neck. To create a work used the material of the Cabinet of color Doppler ultrasonography of the Health Center in Donja Gusterica in a prospective study of a random sample of 60 patients were reviewed in January 2014. Gender analysis examined patients, women were 32 (53.33% and 28 men (46.67%. Looking at the age of examined patients, we have found that most of them 43 (71.67% over the age of 50 years, while we found 17 (28.33% patients under 50 years. Atherosclerotic plaques were diagnosed in 36, a change in the shape of the carotid arteries in 29 patients. Atherosclerotic plaque, we usually find the bifurcation ACC and the Origin ACI in 23 (63.89%. Duplex sonography shows what angioneurologists and vascular surgeons are most interested in: the morphology of arterial lesions and hemodynamic effects.

  14. [Polyurethane vessels for microvascular surgical training to reduce animal use].

    Science.gov (United States)

    Meier, Sonja A; Lang, Axel; Beer, Gertrude M

    2004-01-01

    Systematic training of the manual skills is inevitable in learning microsurgery. Generally, first exercises are done on two-dimensional models, then the training continues on animals. With the growing ethical awareness, the obligation to protect animals and the stricter animal protection laws, realistic three-dimensional models have become necessary for training of microsurgery. However, the available alternatives all have certain disadvantages. We tested vessels made of polyurethane for microvascular surgical training and compared them to the available three-dimensional synthetic alternatives. Rose-coloured (arteries) or blue (veins), opaque vessels with a minimal wall thickness of 0.12 mm and a minimal internal diameter of 1 mm are used. To mimic the surgical access and the depth of the operative field, the vessels can be embedded in a synthetic box with or without a cap. The completed anastomosis is checked by injection of a coloured fluid. The consistency and the variable relation of the thickness of the wall to the internal diameter very closely reflect the biological situation. Even training on very fragile venous walls is possible in all manners. After completion of anastomosis the vessels can be opened longitudinally to check the patency of the anastomotic site. The described polyurethane vessels are very suitable for microsurgical training as a useful step between the two-dimensional model and the animal. The number of animals required for microsurgical training can clearly be reduced by the use of such synthetic polyurethane vessels.

  15. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents1

    Science.gov (United States)

    Galiè, Mirco; D'Onofrio, Mirko; Montani, Maura; Amici, Augusto; Calderan, Laura; Marzola, Pasquina; Benati, Donatella; Merigo, Flavia; Marchini, Cristina; Sbarbati, Andrea

    2005-01-01

    Abstract Contrast-enhanced ultrasound (CEUS) is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 µm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes. PMID:15967105

  16. Vacuum vessels for the LHC magnets arrive at CERN

    CERN Multimedia

    2001-01-01

    The first batch of pre-series vacuum vessels for the LHC dipole magnets has just been delivered to CERN. The vessels are components of the cryostats and will provide the thermal insulation for the superconducting magnets. The first batch of vacuum vessels for the LHC dipole magnets with the team taking part at CERN in ordering and installing them. Left to right : Claude Hauviller, Monique Dupont, Lloyd Williams, Franck Gavin, Alain Jacob, Christophe Vuitton, Davide Bozzini, Laure Sandri, Mikael Sjoholm and André de Saever. In 2006 all that will be seen of the LHC superconducting dipoles in the LHC tunnel will be a line of over 1230 blue cylindrical vacuum vessels. Ten vessels, each weighing 4 tonnes, are already at CERN. On 6 July the first batch of pre-series vessels reached the Lab-oratory from the firm SIMIC Spa whose works are near Savona in north-western Italy. Despite appearances, these 15-metre long, 1-metre diameter blue tubes are much more sophisticated than sections of a run-of-the-mill...

  17. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents

    Directory of Open Access Journals (Sweden)

    Mirco Galiè

    2005-05-01

    Full Text Available Contrast-enhanced ultrasound (CEUS is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 μm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI. Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes.

  18. A Measure of Similarity Between Trajectories of Vessels

    Directory of Open Access Journals (Sweden)

    Le QI

    2016-03-01

    Full Text Available The measurement of similarity between trajectories of vessels is one of the kernel problems that must be addressed to promote the development of maritime intelligent traffic system (ITS. In this study, a new model of trajectory similarity measurement was established to improve the data processing efficiency in dynamic application and to reflect actual sailing behaviors of vessels. In this model, a feature point detection algorithm was proposed to extract feature points, reduce data storage space and save computational resources. A new synthesized distance algorithm was also created to measure the similarity between trajectories by using the extracted feature points. An experiment was conducted to measure the similarity between the real trajectories of vessels. The growth of these trajectories required measurements to be conducted under different voyages. The results show that the similarity measurement between the vessel trajectories is efficient and correct. Comparison of the synthesized distance with the sailing behaviors of vessels proves that results are consistent with actual situations. The experiment results demonstrate the promising application of the proposed model in studying vessel traffic and in supplying reliable data for the development of maritime ITS.

  19. D-Zero Central Calorimeter Pressure Vessel and Vacuum Vessel Safety Notes

    Energy Technology Data Exchange (ETDEWEB)

    Rucinski, R.; Luther, R.; /Fermilab

    1990-10-25

    The relief valve and relief piping capacity was calculated to be 908 sefm air. This exceeds all relieving conditions. The vessel also has a rupture disc with a 2640 scfm air stamped capacity. In order to significantly decrease the amount of time required to fill the cryostats, it is desired to raise the setpoint of the 'operating' relief valve on the argon storage dewar to 20 psig from its existing 16 psig setting. This additional pressure increases the flow to the cryostats and will overwhelm the relief capacity if the temperature of the modules within these vessels is warm enough. Using some conservative assumptions and simple calculations within this note, the maximum average temperature that the modules within each cryostat can be at prior to filling from the storage dewar with liquid argon is at least 290 K. The average temperature of the module mass for any of the three cryostats can be as high as 290 K prior to filling that particular cryostat. This should not be confused with the average temperature of a single type or location which is useful in protecting the modules-not necessarily the vessel itself. A few modules of each type and at different elevations should be used in an average which would account for the different weights of each module. Note that at 290 K, the actual flow of argon through the relief valve and the rupture disk was under the maximum theoretical flows for each relief device. This means that the bulk temperature could actually have been raised to flow argon through the reliefs at their maximum capacity. Therefore, the temperature of 290 K is a conservative value for the calculated flow rate of 12.3 gpm. Safeguards in addition to and used in conjunction with operating procedures shall be implemented in such a way so that the above temperature limitation is not exceeded and such that it is exclusive of the programmable logic controller (PLC). One suggestion is using a toggle switch for each cryostat mounted in the PLC I/O box

  20. Detectability of cerebral aneurysms and surrounding vessels by three-dimensional evaluation using helical scanning CT (HES-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Ogura, Yuko; Katada, Kazuhiro; Sano, Hirotoshi; Kato, Yoko; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko (Fujita Health Univ., Toyoake, Aichi (Japan))

    1994-09-01

    Helical scanning CT (HES-CT) is a new technique to enable high-speed volumetric data acquisition. We have applied HES-CT to the diagnosis of cerebral vascular diseases. In our experience, the relationship between the scanning parameters of HES-CT and image quality was complex and reciprocal, so that optimization of the parameters according to the clinical demands was essential. We compared HES-CT with conventional cerebral angiography to determine the detectability of the aneurysm and surrounding vessels, and sought the optimal parameters to delineate small vessels. All aneurysms were detected in multiplanar reconstruction (MPR) images. The smallest one was 3 x 4 mm. MPR images were found to have some advantages over conventional cerebral angiography in delineation of intracranial aneurysms: (1) scanning was over in a short time (30 s), (2) the relationship between the aneurysm and surrounding vessels was easily recognized, (3) the diameter of the neck could be measured, because the neck of the aneurysm and parent artery could be imaged on the same plane without overlapping another vessel, (4) calcified lesions on the aneurysmal wall were detected, and (5) HES-CT was done safety without arterial puncture. However, the detectability of unknown aneurysm was less than the detectability of known aneurysm in MPR images. The 180deg interpolation algorithm and 1 mm slice were effective in detecting small vessels. However, vessels with a diameter less than 1 mm could not be detected by HES-CT. HES-CT was considered to be useful as a supplementary examination to conventional angiography for the diagnosis of intracranial aneurysms. (author).