WorldWideScience

Sample records for vessel dosimetry applications

  1. Dosimetry for Electron Beam Applications

    DEFF Research Database (Denmark)

    Miller, Arne

    1983-01-01

    This report describes two aspects of electron bean dosimetry, on one hand developaent of thin fil« dosimeters and measurements of their properties, and on the other hand developaent of calorimeters for calibration of routine dosimeters, e.g. thin films. Two types of radiochromic thin film...

  2. Radio-analysis. Applications: biological dosimetry; Radioanalyse. Applications: dosage biologique

    Energy Technology Data Exchange (ETDEWEB)

    Bourrel, F. [CEA Saclay, INSTN, Institut National des Sciences et Techniques Nucleaires, 91 - Gif-sur-Yvette (France); Courriere, Ph. [UFR de Pharmacie, 31 - Toulouse (France)

    2003-06-01

    Radioisotopes have revolutionized the medical biology. Radio-immunology remains the reference measurement of the infinitely small in biology. Constant efforts have been performed to improve the simpleness, detectability and fastness of the method thanks to an increasing automation. This paper presents: 1 - the advantages of compounds labelling and the isotopic dilution; 2 - the antigen-antibody system: properties, determination of the affinity constant using the Scatchard method; 3 - radio-immunologic dosimetry: competitive dosimetry (radioimmunoassay), calibration curve and mathematical data processing, application to the free thyroxine dosimetry, immunoradiometric dosimetry (immunoradiometric assay), evaluation of the analytical efficiency of a radioimmunoassay; 4 - detection of the radioactive signal (solid and liquid scintillation). (J.S.)

  3. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Kori Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Kim, Kwan Hyun; Hong, Joon Wha

    2007-02-15

    This report describes a neutron fluence assessment performed for the Kori Unit 1 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 22 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 1 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 23.

  4. Final report for the 2nd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Yonggwang Unit 2 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 2 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 16 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 2 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  5. Final report for the 3rd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Kori Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai (and others)

    2008-03-15

    This report describes a neutron fluence assessment performed for the Kori Unit 1 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. After Cycle 23 of reactor operation, 3rd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 1 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 24.

  6. Final report for the 1st ex-vessel neutron dosimetry installations and evaluations for Kori unit 2 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 2 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 20 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 20.

  7. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Kori Unit 2 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 21 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 21.

  8. Use of the GATE Monte Carlo package for dosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Visvikis, D. [INSERM U650, LaTIM, University Hospital Medical School, F 29609 Brest (France)]. E-mail: Visvikis.Dimitris@univ-brest.fr; Bardies, M. [INSERM U601, CHU Nantes, F 44093 Nantes (France); Chiavassa, S. [INSERM U601, CHU Nantes, F 44093 Nantes (France); Danford, C. [Department of Medical Physics, MSKCC, New York (United States); Kirov, A. [Department of Medical Physics, MSKCC, New York (United States); Lamare, F. [INSERM U650, LaTIM, University Hospital Medical School, F 29609 Brest (France); Maigne, L. [Departement de Curietherapie-Radiotherapie, Centre Jean Perrin, F 63000 Clemont-Ferrand (France); Staelens, S. [UGent-ELIS, St-Pietersnieuwstraat, 41, B 9000 Gent (Belgium); Taschereau, R. [CRUMP Institute for Molecular Imaging, UCLA, Los Angeles (United States)

    2006-12-20

    One of the roles for Monte Carlo (MC) simulation studies is in the area of dosimetry. A number of different codes dedicated to dosimetry applications are available and widely used today, such as MCNP, EGSnrc and PTRAN. However, such codes do not easily facilitate the description of complicated 3D sources or emission tomography systems and associated data flow, which may be useful in different dosimetry application domains. Such problems can be overcome by the use of specific MC codes such as GATE (GEANT4 Application to Tomographic Emission), which is based on Geant4 libraries, providing a scripting interface with a number of advantages for the simulation of SPECT and PET systems. Despite this potential, its major disadvantage is in terms of efficiency involving long execution times for applications such as dosimetry. The strong points and disadvantages of GATE in comparison to other dosimetry specific codes are discussed and illustrated in terms of accuracy, efficiency and flexibility. A number of features, such as the use of voxelised and moving sources, as well as developments such as advanced visualization tools and the development of dose estimation maps allowing GATE to be used for dosimetry applications are presented. In addition, different examples from dosimetry applications with GATE are given. Finally, future directions with respect to the use of GATE for dosimetry applications are outlined.

  9. Internal dosimetry for blood vessels radiotherapy; Dosimetria interna para terapia com radiacao em vasos sanguineos

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear] E-mail: lpbcampos@uol.com.br; Stabin, Michael Gregory [Vanderbilt Univ., Nashville, TN (United States). Dept. of Radiology and Radiological Sciences] E-mail: Michael.Stabin@mcmail.vanderbilt.edu

    2001-07-01

    Among the cardiovascular diseases, the most common is acute myocardial infarction, which occurs because of the occlusion of one or more coronary arteries. Balloon angioplasty has been a popular treatment which is less invasive than surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment). Known as Intravascular Brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis. In order to study the radiation dosimetry in the patient and radiological protection for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, 0.30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several radionuclides. Advantages and disadvantages of the radionuclides and source geometries are discussed and the dosimetry developed here will aid in the realization of the benefits obtained in patients. (author)

  10. Chemical dosimetry techniques for various applications under different geometries

    CERN Document Server

    Gupta, B L; Narayan, G R; Nilekani, S R

    2000-01-01

    This paper gives the results of dosimetry for various applications under different geometrical arrangements. These applications include: gamma chambers, blood irradiators, radiotherapy using both sup 6 sup 0 Co and accelerators, animal irradiations with different types of radiation sources, fluid irradiators for sludge and rubber latex and industrial electron irradiators. The dosimeters used were Fricke, FBX and alanine/glutamine (spectrophotometric readout).

  11. Luminescence dosimetry: recent developments in theory and applications

    Energy Technology Data Exchange (ETDEWEB)

    McKeever, S.W.S. [Department of Physics, Oklahoma State University, Stillwater, OK 74078-3072 (United States)

    2000-07-01

    Thermally and optically stimulated luminescence have been used in applications in solid state physics, radiation dosimetry and geological dating for several decades. This paper gives a generalized description of these methods in terms of non-equilibrium thermodynamics and in doing so highlights similarities and differences between the methods. Recent advances in both the theory and application of the techniques are highlighted with numerous specific examples. (Author)

  12. 46 CFR 153.9 - Foreign flag vessel endorsement application.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Foreign flag vessel endorsement application. 153.9... Foreign flag vessel endorsement application. (a) Application for a vessel whose flag administration is... endorsement from the cognizant Officer in Charge, Marine Inspection and have aboard the vessel copies of IMO...

  13. Applications of Cherenkov Light Emission for Dosimetry in Radiation Therapy

    Science.gov (United States)

    Glaser, Adam Kenneth

    Since its discovery in the 1930's, the Cherenkov effect has been paramount in the development of high-energy physics research. It results in light emission from charged particles traveling faster than the local speed of light in a dielectric medium. The ability of this emitted light to describe a charged particle's trajectory, energy, velocity, and mass has allowed scientists to study subatomic particles, detect neutrinos, and explore the properties of interstellar matter. However, only recently has the phenomenon been considered in the practical context of medical physics and radiation therapy dosimetry, where Cherenkov light is induced by clinical x-ray photon, electron, and proton beams. To investigate the relationship between this phenomenon and dose deposition, a Monte Carlo plug-in was developed within the Geant4 architecture for medically-oriented simulations (GAMOS) to simulate radiation-induced optical emission in biological media. Using this simulation framework, it was determined that Cherenkov light emission may be well suited for radiation dosimetry of clinically used x-ray photon beams. To advance this application, several novel techniques were implemented to realize the maximum potential of the signal, such as time-gating for maximizing the signal to noise ratio (SNR) and Cherenkov-excited fluorescence for generating isotropic light release in water. Proof of concept experiments were conducted in water tanks to demonstrate the feasibility of the proposed method for two-dimensional (2D) projection imaging, three-dimensional (3D) parallel beam tomography, large field of view 3D cone beam tomography, and video-rate dynamic imaging of treatment plans for a number of common radiotherapy applications. The proposed dosimetry method was found to have a number of unique advantages, including but not limited to its non-invasive nature, water-equivalence, speed, high-resolution, ability to provide full 3D data, and potential to yield data in-vivo. Based on

  14. 46 CFR 184.115 - Applicability to existing vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Applicability to existing vessels. 184.115 Section 184... 100 GROSS TONS) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT General Provisions § 184.115 Applicability to existing vessels. (a) An existing vessel need not comply with §§ 184.402(c), 184.404, 184.410...

  15. Optimization of CR-39 for fast neutron dosimetry applications

    CERN Document Server

    Vilela, E; Giacomelli, G; Giorgini, M; Morelli, B; Patrizii, L; Serra, P; Togo, V

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: sup 2 sup 4 sup 1 Am-Be, sup 2 sup 5 sup 2 Cf and sup 2 sup 3 sup 8 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose.

  16. Updating the INDAC computer application of internal dosimetry; Actualizacion de la aplicacion informatic INDAC de dosimetria interna

    Energy Technology Data Exchange (ETDEWEB)

    Bravo Perez-Tinao, B.; Marchena Gonzalez, P.; Sollet Sanudo, E.; Serrano Calvo, E.

    2013-07-01

    The initial objective of this project is to expand the application INDAC currently used in internal dosimetry services of the Spanish nuclear power plants and Tecnatom for estimating the effective doses of internal dosimetry of workers in direct action. or in-vivo dosimetry. (Author)

  17. RADIATION DOSIMETRY OF THE PRESSURE VESSEL INTERNALS OF THE HIGH FLUX BEAM REACTOR.

    Energy Technology Data Exchange (ETDEWEB)

    HOLDEN,N.E.; RECINIELLO,R.N.; HU,J.P.; RORER,D.C.

    2002-08-18

    In preparation for the eventual decommissioning of the High Flux Beam Reactor after the permanent removal of its fuel elements from the Brookhaven National Laboratory, both measurements and calculations of the decay gamma-ray dose rate have been performed for the reactor pressure vessel and vessel internal structures which included the upper and lower thermal shields, the transition plate, and the control rod blades. The measurements were made using Red Perspex{trademark} polymethyl methacrylate high-level film dosimeters, a Radcal ''peanut'' ion chamber, and Eberline's high-range ion chamber. To compare with measured gamma-ray dose rate, the Monte Carlo MCNP code and geometric progressive Microshield code were used to model the gamma transport and dose buildup.

  18. Dosimetry of a New P-32 Ophthalmic Applicator

    Science.gov (United States)

    Choi, Chang Heon; Han, Hyon Soo; Son, Kwang-Jae; Park, Ul Jae; Ye, Sung-Joon

    2010-11-01

    Purpose: A 90Sr/Y applicator has been used as a β-source for postoperative irradiation after pterygium excision. As an alternative to 90Sr/Y irradiation, we proposed treatments with 32P. This study aims to provide the dosimetry for this new applicator. Method and Materials: A 32P ophthalmic applicator, of which the design and materials were optimally designed by Monte Carlo simulations, was fabricated by the Korea Atomic Energy Research Institute. The absorbed dose at the front surface of the cylindrical 32P applicator was measured by using an extrapolation ionization chamber. Radiochromic film (RCF) was used to measure depth dose distributions and dose profiles at various depths. A micro-MOSFET detector was used for depth dose measurements. Results: The absorbed dose rates to the reference point (i.e., at the centre on the front surface of 32P applicator) were 0.238 ± 0.012 cGy/s for an extrapolation ionization chamber, 0.280 ± 0.001 cGy/s for RCF, and 0.257 ± 0.020 cGy/s for MOSFET. The axial depth dose rate was reduced into approximately 1/10 as 32P betas penetrate every 2 mm depth. Measured data in depths of 1 mm to 3.5 mm agreed with Monte Carlo data. Due to non-uniform absorption of 32P into an absorbent disk, the dose at the centre of trans-axial plane was 2%-4% less than the peak dose around the periphery. We confirmed no leakage of 32P activities and negligible exposure rate around the hand grip of the applicator. Conclusions: The 32P applicator can deliver uniform therapeutic doses to the surface of the conjunctiva, while sparing the lens better than 90Sr/Y applicators. The doses at any points from the 32P applicator can be calculated by using these measured data sets. The safety of 32P applicator was confirmed. However, prior to the clinical application of every new applicator, safety, dose uniformity, and absorbed dose rate at the reference point should be carefully evaluated by the method developed in this study.

  19. Dosimetry of a New P-32 Ophthalmic Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Ye, Sung-Joon [Department of Radiation Oncology, Seoul National University College of Medicine, Seoul Korea 110-744 (Korea, Republic of); Han, Hyon Soo; Son, Kwang-Jae; Park, Ul Jae, E-mail: sye@snu.ac.k [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon Korea 305-353 (Korea, Republic of)

    2010-11-01

    Purpose: A {sup 90}Sr/Y applicator has been used as a {beta}-source for postoperative irradiation after pterygium excision. As an alternative to {sup 90}Sr/Y irradiation, we proposed treatments with {sup 32}P. This study aims to provide the dosimetry for this new applicator. Method and Materials: A {sup 32}P ophthalmic applicator, of which the design and materials were optimally designed by Monte Carlo simulations, was fabricated by the Korea Atomic Energy Research Institute. The absorbed dose at the front surface of the cylindrical {sup 32}P applicator was measured by using an extrapolation ionization chamber. Radiochromic film (RCF) was used to measure depth dose distributions and dose profiles at various depths. A micro-MOSFET detector was used for depth dose measurements. Results: The absorbed dose rates to the reference point (i.e., at the centre on the front surface of {sup 32}P applicator) were 0.238 {+-} 0.012 cGy/s for an extrapolation ionization chamber, 0.280 {+-} 0.001 cGy/s for RCF, and 0.257 {+-} 0.020 cGy/s for MOSFET. The axial depth dose rate was reduced into approximately 1/10 as {sup 32}P betas penetrate every 2 mm depth. Measured data in depths of 1 mm to 3.5 mm agreed with Monte Carlo data. Due to non-uniform absorption of {sup 32}P into an absorbent disk, the dose at the centre of trans-axial plane was 2%-4% less than the peak dose around the periphery. We confirmed no leakage of {sup 32}P activities and negligible exposure rate around the hand grip of the applicator. Conclusions: The {sup 32}P applicator can deliver uniform therapeutic doses to the surface of the conjunctiva, while sparing the lens better than {sup 90}Sr/Y applicators. The doses at any points from the {sup 32}P applicator can be calculated by using these measured data sets. The safety of {sup 32}P applicator was confirmed. However, prior to the clinical application of every new applicator, safety, dose uniformity, and absorbed dose rate at the reference point should be

  20. Computational dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Siebert, B.R.L.; Thomas, R.H.

    1996-01-01

    The paper presents a definition of the term ``Computational Dosimetry`` that is interpreted as the sub-discipline of computational physics which is devoted to radiation metrology. It is shown that computational dosimetry is more than a mere collection of computational methods. Computational simulations directed at basic understanding and modelling are important tools provided by computational dosimetry, while another very important application is the support that it can give to the design, optimization and analysis of experiments. However, the primary task of computational dosimetry is to reduce the variance in the determination of absorbed dose (and its related quantities), for example in the disciplines of radiological protection and radiation therapy. In this paper emphasis is given to the discussion of potential pitfalls in the applications of computational dosimetry and recommendations are given for their avoidance. The need for comparison of calculated and experimental data whenever possible is strongly stressed.

  1. Application of lightweighting technology to military aircraft, vessels, and vehicles

    National Research Council Canada - National Science Library

    2012-01-01

    .... Application of lightweighting technology to military aircraft, vessels, and vehicles assesses the current state of lightweighting implementation in land, sea, and air vehicles and recommends ways...

  2. Dosimetry methods

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, A.; Kovacs, A.

    2003-01-01

    Chemical and physical radiation dosimetry methods, used for the measurement of absorbed dose mainly during the practical use of ionizing radiation, are discussed with respect to their characteristics and fields of application....

  3. Application of numerical analysis methods to thermoluminescence dosimetry; Aplicacion de metodos de analisis numerico a la dosimetria por termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Ros, J. M.; Delgado, A.

    1989-07-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs.

  4. Application of biological dosimetry in accidental radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Nosal, M.; Batora, I.; Kolesar, D.; Stojkovic, J. (Komenskeho Univ., Bratislava (Czechoslovakia). Lekarska Fakulta); Gaal, P.; Sklovsky, A. (Krajska Hygienicka Stanica, Bratislava (Czechoslovakia)); Cizova, O. (Sexuologicka Ambulancia KUNZ, Bratislava (Czechoslovakia))

    1982-03-01

    The case is described of accidental irradiation of a male person with /sup 137/Cs of an activity of 24.71 GBq. The first estimate induced a reasonable suspicion that the absorbed dose could be very high and life-threatening. On the other hand the clinical picture, usual laboratory examinations, findings in the fluorescent blood count, the analysis of chromosomal count of lymphocytes in the peripheral blood, the spermiogram, and the negative post-irradiation porphyrinuria suggested that the absorbed dose could be much lower than the original estimate. The results of dosimetry obtained after the reconstruction of the accident by measuring on a phantom revealed that the actual dose was very close to that presumed from the results of biological dosimetry during the first days of examination of the patient.

  5. Topics in radiation dosimetry radiation dosimetry

    CERN Document Server

    1972-01-01

    Radiation Dosimetry, Supplement 1: Topics in Radiation Dosimetry covers instruments and techniques in dealing with special dosimetry problems. The book discusses thermoluminescence dosimetry in archeological dating; dosimetric applications of track etching; vacuum chambers of radiation measurement. The text also describes wall-less detectors in microdosimetry; dosimetry of low-energy X-rays; and the theory and general applicability of the gamma-ray theory of track effects to various systems. Dose equivalent determinations in neutron fields by means of moderator techniques; as well as developm

  6. A parameterization method and application in breast tomosynthesis dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob [Division of Diagnostic Imaging Physics and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States)

    2013-09-15

    Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized using a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA

  7. Iron-based radiochromic systems for UV dosimetry applications

    Science.gov (United States)

    Lee, Hannah J.; Alqathami, Mamdooh; Blencowe, Anton; Ibbott, Geoffrey

    2018-01-01

    Phototherapy treatment using ultraviolet (UV) A and B light sources has long existed as a treatment option for various skin conditions. Quality control for phototherapy treatment recommended by the British Association of Dermatologists and British Photodermatology Group generally focused on instrumentation-based dosimetry measurements. The purpose of this study was to present an alternative, easily prepared dosimeter system for the measurement of UV dose and as a simple quality assurance technique for phototherapy treatments. Five different UVA-sensitive radiochromic dosimeter formulations were investigated and responded with a measurable and visible optical change both in solution and in gel form. Iron(III) reduction reaction formulations were found to be more sensitive to UVA compared to iron(II) oxidation formulations. One iron(III) reduction formulation was found to be especially promising due to its sensitivity to UVA dose, ease of production, and linear response up to a saturation point.

  8. Dosimetry; La dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Le Couteulx, I.; Apretna, D.; Beaugerie, M.F. [Electricite de France (EDF), 75 - Paris (France)] [and others

    2003-07-01

    Eight articles treat the dosimetry. Two articles evaluate the radiation doses in specific cases, dosimetry of patients in radiodiagnosis, three articles are devoted to detectors (neutrons and x and gamma radiations) and a computer code to build up the dosimetry of an accident due to an external exposure. (N.C.)

  9. Application of spherical diodes for megavoltage photon beams dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Barbés, Benigno, E-mail: bbarbes@unav.es [Servicio de Oncología Radioterápica, Clínica Universidad de Navarra, Avda. Pío XII, 36, E-31008 Pamplona, Navarra (Spain); Azcona, Juan D. [Department of Radiation Oncology, Stanford University, Stanford, California 94305 and Servicio de Oncología Radioterápica, Clínica Universidad de Navarra, Avda. Pío XII 36, E-31008 Pamplona, Navarra (Spain); Burguete, Javier [Departamento de Física y Matemática Aplicada, Facultad de Ciencias, Universidad de Navarra, Irunlarrea 1, E-31008 Pamplona, Navarra (Spain); Martí-Climent, Josep M. [Servicio de Medicina Nuclear, Clínica Universidad de Navarra, Avda. Pío XII 36, E-31008 Pamplona, Navarra (Spain)

    2014-01-15

    using the spherical diode described in this work show its feasibility for the dosimetry of megavoltage photon beams. A particularly important feature is its good angular response in the MV range. They would be good candidates forin vivo dosimetry, and quality assurance of VMAT and tomotherapy, and other modalities with beams irradiating from multiple orientations, such as Cyberknife and ViewRay, with minor modifications.

  10. Quantitative 3D Optical Imaging: Applications in Dosimetry and Biophysics

    Science.gov (United States)

    Thomas, Andrew Stephen

    Optical-CT has been shown to be a potentially useful imaging tool for the two very different spheres of biologists and radiation therapy physicists, but it has yet to live up to that potential. In radiation therapy, researchers have used optical-CT for the readout of 3D dosimeters, but it is yet to be a clinically relevant tool as the technology is too slow to be considered practical. Biologists have used the technique for structural imaging, but have struggled with emission tomography as the reality of photon attenuation for both excitation and emission have made the images quantitatively irrelevant. Dosimetry. The DLOS (Duke Large field of view Optical-CT Scanner) was designed and constructed to make 3D dosimetry utilizing optical-CT a fast and practical tool while maintaining the accuracy of readout of the previous, slower readout technologies. Upon construction/optimization/implementation of several components including a diffuser, band pass filter, registration mount & fluid filtration system the dosimetry system provides high quality data comparable to or exceeding that of commercial products. In addition, a stray light correction algorithm was tested and implemented. The DLOS in combination with the 3D dosimeter it was designed for, PREAGETM, then underwent rigorous commissioning and benchmarking tests validating its performance against gold standard data including a set of 6 irradiations. DLOS commissioning tests resulted in sub-mm isotropic spatial resolution (MTF >0.5 for frequencies of 1.5lp/mm) and a dynamic range of ˜60dB. Flood field uniformity was 10% and stable after 45minutes. Stray light proved to be small, due to telecentricity, but even the residual can be removed through deconvolution. Benchmarking tests showed the mean 3D passing gamma rate (3%, 3mm, 5% dose threshold) over the 6 benchmark data sets was 97.3% +/- 0.6% (range 96%-98%) scans totaling ˜10 minutes, indicating excellent ability to perform 3D dosimetry while improving the speed of

  11. Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications

    Directory of Open Access Journals (Sweden)

    Pradhan A

    2008-01-01

    Full Text Available During the last 10 years, optically stimulated luminescence (OSL has emerged as a formidable competitor not only to thermoluminescence dosimetry (TLD but also to several other dosimetry systems. Though a large number of materials have been synthesized and studied for OSL, Al 2 O 3 :C continues to dominate the dosimetric applications. Re-investigations of OSL in BeOindicate that this material might provide an alternative to Al 2 O 3 :C. Study of OSL of electronic components of mobile phones and ID cards appears to have opened up a feasibility of dosimetry and dose reconstruction using the electronic components of gadgets of everyday use in the events of unforeseen situations of radiological accidents, including the event of a dirty bomb by terrorist groups. Among the newly reported materials, a very recent development of NaMgF 3 :Eu 2+ appears fascinating because of its high OSL sensitivity and tolerable tissue equivalence. In clinical dosimetry, an OSL as a passive dosimeter could do all that TLD can do, much faster with a better or at least the same efficiency; and in addition, it provides a possibility of repeated readout unlike TLD, in which all the dose information is lost in a single readout. Of late, OSL has also emerged as a practical real-time dosimeter for in vivo measurements in radiation therapy (for both external beams and brachytherapy and in various diagnostic radiological examinations including mammography and CT dosimetry. For in vivo measurements, a probe of Al 2 O 3 :C of size of a fraction of a millimeter provides the information on both the dose rate and the total dose from the readout of radioluminescence and OSL signals respectively, from the same probe. The availability of OSL dosimeters in various sizes and shapes and their performance characteristics as compared to established dosimeters such as plastic scintillation dosimeters, diode detectors, MOSFET detectors, radiochromic films, etc., shows that OSL may soon become

  12. Synthetic diamond devices for medical dosimetry applied to radiotherapy; Etude et developpement de dispositifs en diamant synthetique pour la dosimetrie medicale: applications en radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Descamps, C

    2007-06-15

    The aim of this thesis, lead in the framework of an integrated European project entitled M.A.E.S.T.R.O. for ' Methods and Advanced Equipment for Simulation and Treatment in Radio Oncology', was to develop and test synthetic diamond detector in clinical environment for new modalities used in radiotherapy. Diamond is a good candidate for the detection of high energy beams in medical fields. It can be used for passive dosimetry, as thermoluminescent dosimeters or for active dosimetry as ionisation chambers. These two applications are presented here. Concerning the thermoluminescence, several impurities or dopants (boron, phosphorus, and nitrogen) have been incorporated in the diamond films during growth, in order to modify the material dosimetric properties and a detailed study of nitrogen-containing films is proposed. The second part presents the results obtained in active dosimetry. Two guide lines were followed: the measurement set-up optimisation and the material modification. The first dosimetric studies under radiotherapy beams concerning nitrogen-containing polycrystalline diamond as well as high purity single crystal diamond are conclusive. The detectors behaviours are in agreement with the recommendations of the International Atomic Energy Agency (IAEA). (author)

  13. Radiochromic film dosimetry

    CERN Document Server

    Xu Zhi Yong

    2002-01-01

    Radiochromic film dosimetry was developed to measure ionization irradiation dose for industry and medicine. At this time, there are no comprehensive guideline on the medical application, calibration method and densitometer system for medicine. The review gives update on Radiochromic film dosimetry used for medicine, including principles, film model and material, characteristics, calibration method, scanning densitometer system and medical application

  14. Application of jade samples for high-dose dosimetry using the EPR technique

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Instituto de Pesquisas Energeticas e Nucleares/Comissao Nacional de Energia Nuclear Av. Prof. Lineu Prestes 2242, 05508-000, Sao Paulo (Brazil)], E-mail: miteixei@ipen.br; Melo, Adeilson P. [Instituto de Pesquisas Energeticas e Nucleares/Comissao Nacional de Energia Nuclear Av. Prof. Lineu Prestes 2242, 05508-000, Sao Paulo (Brazil); Centro Federal de Educacao Tecnologica de Sergipe, Aracaju (Brazil)], E-mail: adeilson_pessoa_melo@yahoo.com.br; Ferraz, Gilberto M. [Depto. de Fisica Nuclear, Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo (Brazil)], E-mail: gmarconf@if.usp.br; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares/Comissao Nacional de Energia Nuclear Av. Prof. Lineu Prestes 2242, 05508-000, Sao Paulo (Brazil)], E-mail: lcaldas@ipen.br

    2010-04-15

    The dosimeter characteristics of jade samples were studied for application in high-dose dosimetry. Jade is the common denomination of two silicates: jadeite and actinolite. The EPR spectra of different jade samples were obtained after irradiation with absorbed doses of 100 Gy up to 20 kGy. The jade samples present signals that increase with the absorbed dose (g-factors around 2.00); they can be attributed to electron centers. The EPR spectra obtained for the USA jade samples and their main dosimetric properties as reproducibility, calibration curves and energy dependence were investigated.

  15. Verification of Dosimetry Measurements with Timepix Pixel Detectors for Space Applications

    Science.gov (United States)

    Kroupa, M.; Pinsky, L. S.; Idarraga-Munoz, J.; Hoang, S. M.; Semones, E.; Bahadori, A.; Stoffle, N.; Rios, R.; Vykydal, Z.; Jakubek, J.; hide

    2014-01-01

    The current capabilities of modern pixel-detector technology has provided the possibility to design a new generation of radiation monitors. Timepix detectors are semiconductor pixel detectors based on a hybrid configuration. As such, the read-out chip can be used with different types and thicknesses of sensors. For space radiation dosimetry applications, Timepix devices with 300 and 500 microns thick silicon sensors have been used by a collaboration between NASA and University of Houston to explore their performance. For that purpose, an extensive evaluation of the response of Timepix for such applications has been performed. Timepix-based devices were tested in many different environments both at ground-based accelerator facilities such as HIMAC (Heavy Ion Medical Accelerator in Chiba, Japan), and at NSRL (NASA Space Radiation Laboratory at Brookhaven National Laboratory in Upton, NY), as well as in space on board of the International Space Station (ISS). These tests have included a wide range of the particle types and energies, from protons through iron nuclei. The results have been compared both with other devices and theoretical values. This effort has demonstrated that Timepix-based detectors are exceptionally capable at providing accurate dosimetry measurements in this application as verified by the confirming correspondence with the other accepted techniques.

  16. Reactor Dosimetry State of the Art 2008

    Science.gov (United States)

    Voorbraak, Wim; Debarberis, Luigi; D'Hondt, Pierre; Wagemans, Jan

    2009-08-01

    . Williams, A. P. Ribaric and T. Schnauber. Agile high-fidelity MCNP model development techniques for rapid mechanical design iteration / J. A. Kulesza.Extension of Raptor-M3G to r-8-z geometry for use in reactor dosimetry applications / M. A. Hunter, G. Longoni and S. L. Anderson. In vessel exposure distributions evaluated with MCNP5 for Atucha II / J. M. Longhino, H. Blaumann and G. Zamonsky. Atucha I nuclear power plant azimutal ex-vessel flux profile evaluation / J. M. Longhino ... [et al.]. UFTR thermal column characterization and redesign for maximized thermal flux / C. Polit and A. Haghighat. Activation counter using liquid light-guide for dosimetry of neutron burst / M. Hayashi ... [et al.]. Control rod reactivity curves for the annular core research reactor / K. R. DePriest ... [et al.]. Specification of irradiation conditions in VVER-440 surveillance positions / V. Kochkin ... [et al.]. Simulations of Mg-Ar ionisation and TE-TE ionisation chambers with MCNPX in a straightforward gamma and beta irradiation field / S. Nievaart ... [et al.]. The change of austenitic stainless steel elements content in the inner parts of VVER-440 reactor during operation / V. Smutný, J. Hep and P. Novosad. Fast neutron environmental spectrometry using disk activation / G. Lövestam ... [et al.]. Optimization of the neutron activation detector location scheme for VVER-lOOO ex-vessel dosimetry / V. N. Bukanov ... [et al.]. Irradiation conditions for surveillance specimens located into plane containers installed in the WWER-lOOO reactor of unit 2 of the South-Ukrainian NPP / O. V. Grytsenko. V. N. Bukanov and S. M. Pugach. Conformity between LRO mock-ups and VVERS NPP RPV neutron flux attenuation / S. Belousov. Kr. Ilieva and D. Kirilova. FLUOLE: a new relevant experiment for PWR pressure vessel surveillance / D. Beretz ... [et al.]. Transport of neutrons and photons through the iron and water layers / M. J. Kost'ál ... [et al.]. Condition evaluation of spent nuclear fuel assemblies

  17. Fast protocol for radiochromic film dosimetry using a cloud computing web application.

    Science.gov (United States)

    Calvo-Ortega, Juan-Francisco; Pozo, Miquel; Moragues, Sandra; Casals, Joan

    2017-07-01

    To investigate the feasibility of a fast protocol for radiochromic film dosimetry to verify intensity-modulated radiotherapy (IMRT) plans. EBT3 film dosimetry was conducted in this study using the triple-channel method implemented in the cloud computing application (Radiochromic.com). We described a fast protocol for radiochromic film dosimetry to obtain measurement results within 1h. Ten IMRT plans were delivered to evaluate the feasibility of the fast protocol. The dose distribution of the verification film was derived at 15, 30, 45min using the fast protocol and also at 24h after completing the irradiation. The four dose maps obtained per plan were compared using global and local gamma index (5%/3mm) with the calculated one by the treatment planning system. Gamma passing rates obtained for 15, 30 and 45min post-exposure were compared with those obtained after 24h. Small differences respect to the 24h protocol were found in the gamma passing rates obtained for films digitized at 15min (global: 99.6%±0.9% vs. 99.7%±0.5%; local: 96.3%±3.4% vs. 96.3%±3.8%), at 30min (global: 99.5%±0.9% vs. 99.7%±0.5%; local: 96.5%±3.2% vs. 96.3±3.8%) and at 45min (global: 99.2%±1.5% vs. 99.7%±0.5%; local: 96.1%±3.8% vs. 96.3±3.8%). The fast protocol permits dosimetric results within 1h when IMRT plans are verified, with similar results as those reported by the standard 24h protocol. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Standard Practice for Application and Analysis of Nuclear Research Emulsions for Fast Neutron Dosimetry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 Nuclear Research Emulsions (NRE) have a long and illustrious history of applications in the physical sciences, earth sciences and biological sciences (1,2) . In the physical sciences, NRE experiments have led to many fundamental discoveries in such diverse disciplines as nuclear physics, cosmic ray physics and high energy physics. In the applied physical sciences, NRE have been used in neutron physics experiments in both fission and fusion reactor environments (3-6). Numerous NRE neutron experiments can be found in other applied disciplines, such as nuclear engineering, environmental monitoring and health physics. Given the breadth of NRE applications, there exist many textbooks and handbooks that provide considerable detail on the techniques used in the NRE method. As a consequence, this practice will be restricted to the application of the NRE method for neutron measurements in reactor physics and nuclear engineering with particular emphasis on neutron dosimetry in benchmark fields (see Matrix E706). 1...

  19. Thermoluminescent properties of CVD diamond: applications to ionising radiation dosimetry; Proprietes thermoluminescentes du diamant CVD: applications a la dosimetrie des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    Petitfils, A

    2007-09-15

    Remarkable properties of synthetic diamond (human soft tissue equivalence, chemical stability, non-toxicity) make this material suitable for medical application as thermoluminescent dosimeter (TLD). This work highlights the interest of this material as radiotherapy TLD. In the first stage of this work, we looked after thermoluminescent (TL) and dosimetric properties of polycrystalline diamond made by Chemically Vapor Deposited (CVD) synthesis. Dosimetric characteristics are satisfactory as TLD for medical application. Luminescence thermal quenching on diamond has been investigated. This phenomenon leads to a decrease of dosimetric TL peak sensitivity when the heating rate increases. The second part of this work analyses the use of synthetic diamond as TLD in radiotherapy. Dose profiles, depth dose distributions and the cartography of an electron beam obtained with our samples are in very good agreement with results from an ionisation chamber. It is clearly shown that CVD) diamond is of interest to check beams of treatment accelerators. The use of these samples in a control of treatment with Intensity Modulated Radiation Therapy underlines good response of synthetic diamond in high dose gradient areas. These results indicate that CVD diamond is a promising material for radiotherapy dosimetry. (author)

  20. Radiation protection and dosimetry issues in the medical applications of ionizing radiation

    Science.gov (United States)

    Vaz, Pedro

    2014-11-01

    The technological advances that occurred during the last few decades paved the way to the dissemination of CT-based procedures in radiology, to an increasing number of procedures in interventional radiology and cardiology as well as to new techniques and hybrid modalities in nuclear medicine and in radiotherapy. These technological advances encompass the exposure of patients and medical staff to unprecedentedly high dose values that are a cause for concern due to the potential detrimental effects of ionizing radiation to the human health. As a consequence, new issues and challenges in radiological protection and dosimetry in the medical applications of ionizing radiation have emerged. The scientific knowledge of the radiosensitivity of individuals as a function of age, gender and other factors has also contributed to raising the awareness of scientists, medical staff, regulators, decision makers and other stakeholders (including the patients and the public) for the need to correctly and accurately assess the radiation induced long-term health effects after medical exposure. Pediatric exposures and their late effects became a cause of great concern. The scientific communities of experts involved in the study of the biological effects of ionizing radiation have made a strong case about the need to undertake low dose radiation research and the International System of Radiological Protection is being challenged to address and incorporate issues such as the individual sensitivities, the shape of dose-response relationship and tissue sensitivity for cancer and non-cancer effects. Some of the answers to the radiation protection and dosimetry issues and challenges in the medical applications of ionizing radiation lie in computational studies using Monte Carlo or hybrid methods to model and simulate particle transport in the organs and tissues of the human body. The development of sophisticated Monte Carlo computer programs and voxel phantoms paves the way to an accurate

  1. The practical application of scintillation dosimetry in small-field photon-beam radiotherapy.

    Science.gov (United States)

    Burke, Elisa; Poppinga, Daniela; Schönfeld, Andreas A; Harder, Dietrich; Poppe, Björn; Looe, Hui Khee

    2017-03-22

    Plastic scintillation detectors are a new instrument of stereotactic photon-beam dosimetry. The clinical application of the plastic scintillation detector Exradin W1 at the Siemens Artiste and Elekta Synergy accelerators is a matter of current interest. In order to reduce the measurement uncertainty, precautions have to be taken with regard to the geometrical arrangement of the scintillator, the light-guide fiber and the photodiode in the radiation field. To determine the "Cerenkov light ratio" CLR with a type A uncertainty below 1%, the Cerenkov calibration procedure for small-field measurements based on the two-channel spectral method was used. Output factors were correctly measured with the W1 for field sizes down to 0.5×0.5cm(2) with a type A uncertainty of 1.8%. Measurements of small field dose profiles and percentage depth dose curves were carried out with the W1 using automated water phantom profile scans, and a type A uncertainty for dose maxima of 1.4% was achieved. The agreement with a synthetic diamond detector (microDiamond, PTW Freiburg) and a plane parallel ionization chamber (Roos chamber, PTW Freiburg) in relative dose measurements was excellent. In oversight of all results, the suitability of the plastic scintillation detector Exradin W1 for clinical dosimetry under stereotactic conditions, in particular the tried and tested procedures for CLR determination, output factor measurement and automated dose profile scans in water phantoms, have been confirmed. Copyright © 2017. Published by Elsevier GmbH.

  2. Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times.

    Science.gov (United States)

    De Lin, Ming; Toncheva, Greta; Nguyen, Giao; Kim, Sangroh; Anderson-Evans, Colin; Johnson, G Allan; Yoshizumi, Terry T

    2008-08-01

    Digital subtraction angiography (DSA) X-ray imaging for small animals can be used for functional phenotyping given its ability to capture rapid physiological changes at high spatial and temporal resolution. The higher temporal and spatial requirements for small-animal imaging drive the need for short, high-flux X-ray pulses. However, high doses of ionizing radiation can affect the physiology. The purpose of this study was to verify and apply metal oxide semiconductor field effect transistor (MOSFET) technology to dosimetry for small-animal diagnostic imaging. A tungsten anode X-ray source was used to expose a tissue-equivalent mouse phantom. Dose measurements were made on the phantom surface and interior. The MOSFETs were verified with thermoluminescence dosimeters (TLDs). Bland-Altman analysis showed that the MOSFET results agreed with the TLD results (bias, 0.0625). Using typical small animal DSA scan parameters, the dose ranged from 0.7 to 2.2 cGy. Application of the MOSFETs in the small animal environment provided two main benefits: (1) the availability of results in near real-time instead of the hours needed for TLD processes and (2) the ability to support multiple exposures with different X-ray techniques (various of kVp, mA and ms) using the same MOSFET. This MOSFET technology has proven to be a fast, reliable small animal dosimetry method for DSA imaging and is a good system for dose monitoring for serial and gene expression studies.

  3. Development of europium doped BaSO4 TL OSL dual phosphor for radiation dosimetry applications

    Science.gov (United States)

    Patle, Anita; Patil, R. R.; Kulkarni, M. S.; Bhatt, B. C.; Moharil, S. V.

    2015-08-01

    This paper presents the results on the preparation and characterization of Europium-doped Barium sulfate (BaSO4: Eu) TL /OSL dual phosphor. The OSL sensitivity was found to be 11% of the commercially available Al2O3: C, using area integration method. The sample also shows good TL sensitivity and the dosimetric peak appears around 190°C with a shoulder at 282°C. After OSL readout, No change in the TL glow curve is observed. Since the observed TL peaks are not responsible for the observed OSL, good OSL as well as TL sensitivity and low fading will make this phosphor suitable for applications in radiation dosimetry using OSL as well as TL.

  4. Development of A phantom for ophthalmic beta source applicator quality control using TL dosimetry

    Science.gov (United States)

    Barbosa, N. A.; da Rosa, L. A. R.; Braz, D.

    2015-11-01

    Concave eye applicators with 90Sr/90Y and 106Ru/106Rh beta ray sources are usually used in brachytherapy for the treatment of superficial intraocular tumors as uveal melanoma with thickness up to 5 mm. The calculation of the dose delivered to the eye is carried out based on the data present in the beta source calibration certificate. Therefore, it would be interesting to have a system that could evaluate that dose. In this work, an eye phantom to be used with 106Ru/106Rh betatherapy applicators was developed in solid water. This phantom can hold nine micro-cube thermoluminescent (TL) dosimeters, TLD-100. The characteristics of the TL response of the dosimeters, namely reproducibility and individual sensitivity, were determined for a 60Co source. Using Monte Carlo code MCNPX, the dose to a water eye was determined at different depths. Exposing the eye phantom with TL dosimeters to the 106Ru/106Rh applicator, it is possible to assess calibration factors using the dose values obtained by Monte Carlo simulation to each depth. Using mean calibration factors, dose values obtained by TL dosimetry were compared to the data present in the applicators certificate. Mean differences for both applicators were lower than ±10%, maximum value 17% and minimum value 0.08%. Considering that the certificate values present an uncertainty of ±20%, the calibration procedure and the developed phantom are validated and can be applied.

  5. 49 CFR 176.5 - Application to vessels.

    Science.gov (United States)

    2010-10-01

    ... (explosive) materials, Class 3 (flammable liquids), or Division 2.1 (flammable gas) materials, in which case... extinguish fire as the Coast Guard may prescribe; (7) A cable vessel, dredge, elevator vessel, fireboat...

  6. Radiation dosimetry

    CERN Document Server

    Hine, Gerald J; Hine, Gerald J

    1956-01-01

    Radiation Dosimetry focuses on the advancements, processes, technologies, techniques, and principles involved in radiation dosimetry, including counters and calibration and standardization techniques. The selection first offers information on radiation units and the theory of ionization dosimetry and interaction of radiation with matter. Topics include quantities derivable from roentgens, determination of dose in roentgens, ionization dosimetry of high-energy photons and corpuscular radiations, and heavy charged particles. The text then examines the biological and medical effects of radiation,

  7. Rare Earth Doped Silica Optical Fibre Sensors for Dosimetry in Medical and Technical Applications

    Directory of Open Access Journals (Sweden)

    N. Chiodini

    2014-01-01

    Full Text Available Radioluminescence optical fibre sensors are gaining importance since these devices are promising in several applications like high energy physics, particle tracking, real-time monitoring of radiation beams, and radioactive waste. Silica optical fibres play an important role thanks to their high radiation hardness. Moreover, rare earths may be incorporated to optimise the scintillation properties (emission spectrum, decay time according to the particular application. This makes doped silica optical fibres a very versatile tool for the detection of ionizing radiation in many contexts. Among the fields of application of optical fibre sensors, radiation therapy represents a driving force for the research and development of new devices. In this review the recent progresses in the development of rare earth doped silica fibres for dosimetry in the medical field are described. After a general description of advantages and challenges for the use of optical fibre based dosimeter during radiation therapy treatment and diagnostic irradiations, the features of the incorporation of rare earths in the silica matrix in order to prepare radioluminescent optical fibre sensors are presented and discussed. In the last part of this paper, recent results obtained by using cerium, europium, and ytterbium doped silica optical fibres in radiation therapy applications are reviewed.

  8. Preliminary study for precision dosimetry using electron paramagnetic resonance (EPR) in radiotherapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Shehzadi, N. N.; Kim, I. J.; Yi, C. Y. [Center for Ionizing Radiation, Korea Research for Standards and Science, Daejeon (Korea, Republic of)

    2015-10-15

    EPR (Electron paramagnetic resonance) dosimetry for radiotherapy dose range (1-10 Gy) is still being established.Alanine is an important material for EPR dosimetry because in terms of density and radiation absorption properties, it is water equivalent. High repeatability and high reproducibility of alanine spectrum measurement makes it possible to estimate the irradiation dose accurately. This baseline study has been carried out to establish precision EPR dosimetry in therapeutic photon range. For that purpose, an EPR dosimetry system has been setup and repeatability as well as reproducibility of measurements using alanine dosimeter have been evaluated. Effect of anisotropy of alanine dosimeter in spectrometer cavity has also been observed. EPR dosimetry system is set up at KRISS. It is found that reproducibility of the system at therapeutic photon range is 1.5 % - 6.6 %.

  9. Dosimetry Service

    CERN Multimedia

    2006-01-01

    Cern Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry Dosimetry Service is open every morning from 8.30 - 12.00. Closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after the use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel. 7 2155 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  10. The dosimetry of ionizing radiation

    CERN Document Server

    1990-01-01

    A continuation of the treatise The Dosimetry of Ionizing Radiation, Volume III builds upon the foundations of Volumes I and II and the tradition of the preceeding treatise Radiation Dosimetry. Volume III contains three comprehensive chapters on the applications of radiation dosimetry in particular research and medical settings, a chapter on unique and useful detectors, and two chapters on Monte Carlo techniques and their applications.

  11. Application of RADPOS in Vivo Dosimetry for QA of High Dose Rate Brachytherapy

    DEFF Research Database (Denmark)

    Cherpak, A.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Cygler, J.

    2012-01-01

    Purpose: The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing for simultaneous online measurements of dose and spatial position. In this work, we assess the potential use of RADPOS for measurements of motion and dose during prostate HDR......Gy. Conclusions: In vivo dosimetry can potentially signal errors in catheter placement or numbering before entire dose is delivered. The demonstrated accuracy of RADPOS dose measurements and its ability to simultaneously measure displacement makes it a powerful tool for HDR brachytherapy treatments for prostate...

  12. Evaluation of GAF chromic dosimetry and its application to PDD and OCR curves

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Yasushi; Takahashi, Shinobu; Komatsu, Akio [Shimane Medical Univ., Izumo (Japan). Hospital; Uchida, Nobue; Kato, Hirokazu

    2001-11-01

    GAF Chromic Dosimetry Media (GAF Media, Nuclear Associates Co. Ltd.) has been newly developed for the purpose of absorbed dose measurements with ionizing radiation. GAF Media is colorless and transparent before radiation exposure, and it changes progressively to a darker blue color with exposure. In contrast to conventional film, GAF Media can be used in room light and does not require any other procedure to develop or fix the image. In this study, we used a microdensitometer to evaluate the relationship between the absorbed dose and optical density of GAF Media types MD-55 and HD-810. We discuss the possibility of application of GAF Media as a simple dosimeter of percent depth dose (PDD) and off-center ratio (OCR) in the field of quality assurance (QA) of radiotherapy. The optical density derived by GAF Media could be converted into absorbed dose by using an approximation curve. However, the elevation of baseline density, the ''fog effect'', according to time was too great to be neglected. To measure the absorbed spectrum of GAF Media a microdensitometer attached with a Band Pass Filter, which selectively absorbed the spectrum at 671 nm, was useful. The PDD and OCR curves derived by GAF Media were accurate enough for QA of radiotherapy. GAF Media was simple to use, but further investigation will be required before applying it in other fields. (author)

  13. Study of TSL and OSL properties of dental ceramics for accidental dosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Veronese, Ivan, E-mail: ivan.veronese@unimi.i [Dipartimento di Fisica, Universita degli Studi di Milano and INFN Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Galli, Anna [CNR-INFM, via Cozzi 53, 20125 Milano (Italy); Dipartimento di Scienza dei Materiali, Universita degli Studi di Milano Bicocca and INFN Sezione di Milano Bicocca, via Cozzi 53, 20125 Milano (Italy); Cantone, Marie Claire [Dipartimento di Fisica, Universita degli Studi di Milano and INFN Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Martini, Marco [Dipartimento di Scienza dei Materiali, Universita degli Studi di Milano Bicocca and INFN Sezione di Milano Bicocca, via Cozzi 53, 20125 Milano (Italy); Vernizzi, Fabrizio; Guzzi, Gianpaolo [Italian Association for Metals and Biocompatibility Research - A.I.R.M.E.B., Milan (Italy)

    2010-01-15

    Interest is increasing in the development of new methodologies for accidental dose assessment, exploiting the luminescence and dosimetric properties of objects and materials which can be usually found directly on exposed subjects and/or in the contaminated area. In this work, several types of ceramics employed for dental prosthetics restoration, including both innovative materials used as sub-frames for the construction of the inner part of dental crowns (core), and conventional porcelains used for the fabrication of the external layer (veneer), were investigated with regard to their thermally and optically stimulated luminescence (TSL and OSL respectively) properties, in view of their potential application in accidental dosimetry. The sensitivity to ionizing radiation proved to strongly depend on the type and brand of ceramic, with minimum detectable dose ranging from few mGy up to several tens of mGy. A linear dose-response was observed for most of the samples. However, the luminescence signals were characterised by a significant fading, which has to be taken into account for a reliable accidental dose assessment after a radiation exposure event.

  14. Thermoluminescence Dosimetry Applied to Radiation Protection

    DEFF Research Database (Denmark)

    Christensen, Poul; Bøtter-Jensen, Lars; Majborn, Benny

    1982-01-01

    This is a general review of the present state of the development and application of thermoluminescence dosimetry (TLD) for radiation protection purposes. A description is given of commonly used thermoluminescent dosimeters and their main dosimetric properties, e.g. energy response, dose range......, fading, and LET dependence. The applications of thermoluminescence dosimetry in routine personnel monitoring, accident dosimetry, u.v. radiation dosimetry, and environmental monitoring are discussed with particular emphasis on current problems in routine personnel monitoring. Finally, the present state...

  15. Application of the OSL dosimetry technique in the identification of irradiated foods, such as condiments and spices

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Catherine C.O.; Alencar, Marcus A.V. de, E-mail: vallim@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    The use of ionizing radiation in food preservation is considered a well-established technique, so many countries, including Brazil, now allow the use of irradiated foods. Many methods have been tested for dosimetry and identification of irradiated foods including thermoluminescence, electron paramagnetic resonance, and others based on microbiological changes and in viscosity, and which requires a sample processing. The technique of optically stimulated luminescence (OSL) presents an advantage over other methods mentioned: The samples may be used without the need for a prior processing. This work aims to study the OSL properties of condiments and spices irradiated, in order to verify the possibility of the application of the OSL technique in identifying and dosimetry of irradiated foods. The samples used were of four kinds of spices: cumin, oregano, white pepper and black pepper. All samples were subjected to gamma irradiation from a Co-60 source with dose values of kerma in air of 100 Gy to 35 kGy. The samples of cumin presents the OSL signal, however, is only possible to identify whether the condiment was irradiated or not. The sample of oregano also presents the OSL signal, and for this condiment is possible to identify addition to its irradiation, the value of dose. The black pepper and white pepper samples don't presents the OSL signal. The results obtained in this study indicate the possibility of using the OSL technique for the identification and dosimetry of irradiated foods. (author)

  16. The dosimetry of ionizing radiation

    CERN Document Server

    Bjaerngard, Bengt E; Kase, Kenneth R

    1987-01-01

    The Dosimetry of Ionizing Radiation, Volume II, attempts to fill the need for updated reference material on the field of radiation dosimetry. This book presents some broad topics in dosimetry and a variety of radiation dosimetry instrumentation and its application. The book opens with a chapter that extends and applies the concepts of microdosimetry to biological systems. This is followed by separate chapters on the state- of-the-art equipment and techniques used to determine neutron spectra; studies to determine recombination effects in ionization chambers exposed to high-intensity pulsed ra

  17. A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Sarrut, David, E-mail: david.sarrut@creatis.insa-lyon.fr [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon (France); Université Lyon 1 (France); Centre Léon Bérard (France); Bardiès, Manuel; Marcatili, Sara; Mauxion, Thibault [Inserm, UMR1037 CRCT, F-31000 Toulouse, France and Université Toulouse III-Paul Sabatier, UMR1037 CRCT, F-31000 Toulouse (France); Boussion, Nicolas [INSERM, UMR 1101, LaTIM, CHU Morvan, 29609 Brest (France); Freud, Nicolas; Létang, Jean-Michel [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, Centre Léon Bérard, 69008 Lyon (France); Jan, Sébastien [CEA/DSV/I2BM/SHFJ, Orsay 91401 (France); Loudos, George [Department of Medical Instruments Technology, Technological Educational Institute of Athens, Athens 12210 (Greece); Maigne, Lydia; Perrot, Yann [UMR 6533 CNRS/IN2P3, Université Blaise Pascal, 63171 Aubière (France); Papadimitroulas, Panagiotis [Department of Biomedical Engineering, Technological Educational Institute of Athens, 12210, Athens (Greece); Pietrzyk, Uwe [Institut für Neurowissenschaften und Medizin, Forschungszentrum Jülich GmbH, 52425 Jülich, Germany and Fachbereich für Mathematik und Naturwissenschaften, Bergische Universität Wuppertal, 42097 Wuppertal (Germany); Robert, Charlotte [IMNC, UMR 8165 CNRS, Universités Paris 7 et Paris 11, Orsay 91406 (France); and others

    2014-06-15

    In this paper, the authors' review the applicability of the open-source GATE Monte Carlo simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry applications. The many applications of GATE for state-of-the-art radiotherapy simulations are described including external beam radiotherapy, brachytherapy, intraoperative radiotherapy, hadrontherapy, molecular radiotherapy, and in vivo dose monitoring. Investigations that have been performed using GEANT4 only are also mentioned to illustrate the potential of GATE. The very practical feature of GATE making it easy to model both a treatment and an imaging acquisition within the same frameworkis emphasized. The computational times associated with several applications are provided to illustrate the practical feasibility of the simulations using current computing facilities.

  18. A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications.

    Science.gov (United States)

    Sarrut, David; Bardiès, Manuel; Boussion, Nicolas; Freud, Nicolas; Jan, Sébastien; Létang, Jean-Michel; Loudos, George; Maigne, Lydia; Marcatili, Sara; Mauxion, Thibault; Papadimitroulas, Panagiotis; Perrot, Yann; Pietrzyk, Uwe; Robert, Charlotte; Schaart, Dennis R; Visvikis, Dimitris; Buvat, Irène

    2014-06-01

    In this paper, the authors' review the applicability of the open-source GATE Monte Carlo simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry applications. The many applications of GATE for state-of-the-art radiotherapy simulations are described including external beam radiotherapy, brachytherapy, intraoperative radiotherapy, hadrontherapy, molecular radiotherapy, and in vivo dose monitoring. Investigations that have been performed using GEANT4 only are also mentioned to illustrate the potential of GATE. The very practical feature of GATE making it easy to model both a treatment and an imaging acquisition within the same framework is emphasized. The computational times associated with several applications are provided to illustrate the practical feasibility of the simulations using current computing facilities.

  19. Draft report: application of organic Rankine cycle heat recovery systems to diesel powered marine vessels

    Energy Technology Data Exchange (ETDEWEB)

    1977-07-15

    The analysis and results of an investigation of the application of organic Rankine cycle heat recovery systems to diesel-powered marine vessels are described. The program under which this study was conducted was sponsored jointly by the US Energy Research and Development Administration, the US Navy, and the US Maritime Administration. The overall objective of this study was to investigate diesel bottoming energy recovery systems, currently under development by three US concerns, to determine the potential for application to marine diesel propulsion and auxiliary systems. The study primarily focused on identifying the most promising vessel applications (considering vessel type, size, population density, operational duty cycle, etc.) so the relative economic and fuel conservation merits of energy recovery systems could be determined and assessed. Vessels in the current fleet and the projected 1985 fleet rated at 1000 BHP class and above were investigated.

  20. Dosimetry; Dosimetria

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Adauto de Souza; Almeida, Eduardo de; Elias, Elimoel Abrao; Cunha e Silva, Richard Maximiliano da

    1998-07-01

    This document contains a comprehensive work on dosimetry, covering the following subjects: radiological quantities and unities; the biological effects os ionizing radiations; dose calculations; permissive maximum dose; safety requirements; precautions; and the radioisotopes laboratory.

  1. High frequency electromagnetic dosimetry

    CERN Document Server

    Sánchez-Hernández, David A

    2009-01-01

    Along with the growth of RF and microwave technology applications, there is a mounting concern about the possible adverse effects over human health from electromagnetic radiation. Addressing this issue and putting it into perspective, this groundbreaking resource provides critical details on the latest advances in high frequency electromagnetic dosimetry.

  2. Engineering a Blood Vessel Network Module for Body-on-a-Chip Applications.

    Science.gov (United States)

    Ryu, Hyunryul; Oh, Soojung; Lee, Hyun Jae; Lee, Jin Young; Lee, Hae Kwang; Jeon, Noo Li

    2015-06-01

    The blood circulatory system links all organs from one to another to support and maintain each organ's functions consistently. Therefore, blood vessels have been considered as a vital unit. Engineering perfusable functional blood vessels in vitro has been challenging due to difficulties in designing the connection between rigid macroscale tubes and fragile microscale ones. Here, we propose a generalizable method to engineer a "long" perfusable blood vessel network. To form millimeter-scale vessels, fibroblasts were co-cultured with human umbilical vein endothelial cells (HUVECs) in close proximity. In contrast to previous works, in which all cells were permanently placed within the device, we developed a novel method to culture paracrine factor secreting fibroblasts on an O-ring-shaped guide that can be transferred in and out. This approach affords flexibility in co-culture, where the effects of secreted factors can be decoupled. Using this, blood vessels with length up to 2 mm were successfully produced in a reproducible manner (>90%). Because the vessels form a perfusable network within the channel, simple links to inlets and outlets of the device allowed connections to the outside world. The robust and reproducible formation of in vitro engineered vessels can be used as a module to link various organ components as parts of future body-on-a-chip applications. © 2014 Society for Laboratory Automation and Screening.

  3. Low-cost flexible thin-film detector for medical dosimetry applications.

    Science.gov (United States)

    Zygmanski, P; Abkai, C; Han, Z; Shulevich, Y; Menichelli, D; Hesser, J

    2014-03-06

    The purpose of this study is to characterize dosimetric properties of thin film photovoltaic sensors as a platform for development of prototype dose verification equipment in radiotherapy. Towards this goal, flexible thin-film sensors of dose with embedded data acquisition electronics and wireless data transmission are prototyped and tested in kV and MV photon beams. Fundamental dosimetric properties are determined in view of a specific application to dose verification in multiple planes or curved surfaces inside a phantom. Uniqueness of the new thin-film sensors consists in their mechanical properties, low-power operation, and low-cost. They are thinner and more flexible than dosimetric films. In principle, each thin-film sensor can be fabricated in any size (mm² - cm² areas) and shape. Individual sensors can be put together in an array of sensors spreading over large areas and yet being light. Photovoltaic mode of charge collection (of electrons and holes) does not require external electric field applied to the sensor, and this implies simplicity of data acquisition electronics and low power operation. The prototype device used for testing consists of several thin film dose sensors, each of about 1.5 cm × 5 cm area, connected to simple readout electronics. Sensitivity of the sensors is determined per unit area and compared to EPID sensitivity, as well as other standard photodiodes. Each sensor independently measures dose and is based on commercially available flexible thin-film aSi photodiodes. Readout electronics consists of an ultra low-power microcontroller, radio frequency transmitter, and a low-noise amplification circuit implemented on a flexible printed circuit board. Detector output is digitized and transmitted wirelessly to an external host computer where it is integrated and processed. A megavoltage medical linear accelerator (Varian Tx) equipped with kilovoltage online imaging system and a Cobalt source are used to irradiate different thin

  4. Fine-grained visual marine vessel classification for coastal surveillance and defense applications

    Science.gov (United States)

    Solmaz, Berkan; Gundogdu, Erhan; Karaman, Kaan; Yücesoy, Veysel; Koç, Aykut

    2017-10-01

    The need for capabilities of automated visual content analysis has substantially increased due to presence of large number of images captured by surveillance cameras. With a focus on development of practical methods for extracting effective visual data representations, deep neural network based representations have received great attention due to their success in visual categorization of generic images. For fine-grained image categorization, a closely related yet a more challenging research problem compared to generic image categorization due to high visual similarities within subgroups, diverse applications were developed such as classifying images of vehicles, birds, food and plants. Here, we propose the use of deep neural network based representations for categorizing and identifying marine vessels for defense and security applications. First, we gather a large number of marine vessel images via online sources grouping them into four coarse categories; naval, civil, commercial and service vessels. Next, we subgroup naval vessels into fine categories such as corvettes, frigates and submarines. For distinguishing images, we extract state-of-the-art deep visual representations and train support-vector-machines. Furthermore, we fine tune deep representations for marine vessel images. Experiments address two scenarios, classification and verification of naval marine vessels. Classification experiment aims coarse categorization, as well as learning models of fine categories. Verification experiment embroils identification of specific naval vessels by revealing if a pair of images belongs to identical marine vessels by the help of learnt deep representations. Obtaining promising performance, we believe these presented capabilities would be essential components of future coastal and on-board surveillance systems.

  5. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images

    Energy Technology Data Exchange (ETDEWEB)

    Leal Neto, Viriato, E-mail: viriatoleal@yahoo.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil); Vieira, Jose Wilson [Universidade Federal de Pernambuco (UPE), Recife, PE (Brazil); Lima, Fernando Roberto de Andrade [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-09-15

    Objective: this article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. Materials and methods: a software called DoRadIo (Dosimetria das Radiacoes Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C ⧣ programming language. Results: with the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. Conclusion: the user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity. (author)

  6. Infants and young children modeling method for numerical dosimetry studies: application to plane wave exposure

    Science.gov (United States)

    Dahdouh, S.; Varsier, N.; Nunez Ochoa, M. A.; Wiart, J.; Peyman, A.; Bloch, I.

    2016-02-01

    Numerical dosimetry studies require the development of accurate numerical 3D models of the human body. This paper proposes a novel method for building 3D heterogeneous young children models combining results obtained from a semi-automatic multi-organ segmentation algorithm and an anatomy deformation method. The data consist of 3D magnetic resonance images, which are first segmented to obtain a set of initial tissues. A deformation procedure guided by the segmentation results is then developed in order to obtain five young children models ranging from the age of 5 to 37 months. By constraining the deformation of an older child model toward a younger one using segmentation results, we assure the anatomical realism of the models. Using the proposed framework, five models, containing thirteen tissues, are built. Three of these models are used in a prospective dosimetry study to analyze young child exposure to radiofrequency electromagnetic fields. The results lean to show the existence of a relationship between age and whole body exposure. The results also highlight the necessity to specifically study and develop measurements of child tissues dielectric properties.

  7. Application of Cerenkov radiation generated in plastic optical fibers for therapeutic photon beam dosimetry.

    Science.gov (United States)

    Jang, Kyoung Won; Yagi, Takahiro; Pyeon, Cheol Ho; Yoo, Wook Jae; Shin, Sang Hun; Jeong, Chiyoung; Min, Byung Jun; Shin, Dongho; Misawa, Tsuyoshi; Lee, Bongsoo

    2013-02-01

    A Cerenkov fiber-optic dosimeter (CFOD) is fabricated using plastic optical fibers to measure Cerenkov radiation induced by a therapeutic photon beam. We measured the Cerenkov radiation generated in optical fibers in various irradiation conditions to evaluate the usability of Cerenkov radiation for a photon beam therapy dosimetry. As a results, the spectral peak of Cerenkov radiation was measured at a wavelength of 515 nm, and the intensity of Cerenkov radiation increased linearly with increasing irradiated length of the optical fiber. Also, the intensity peak of Cerenkov radiation was measured in the irradiation angle range of 30 to 40 deg. In the results of Monte Carlo N-particle transport code simulations, the relationship between fluxes of electrons over Cerenkov threshold energy and energy deposition of a 6 MV photon beam had a nearly linear trend. Finally, percentage depth doses for the 6 MV photon beam could be obtained using the CFOD and the results were compared with those of an ionization chamber. Here, the mean dose difference was about 0.6%. It is anticipated that the novel and simple CFOD can be effectively used for measuring depth doses in radiotherapy dosimetry.

  8. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  9. (Biological dosimetry)

    Energy Technology Data Exchange (ETDEWEB)

    Preston, R.J.

    1990-12-17

    The traveler attended the 1st International Conference on Biological Dosimetry in Madrid, Spain. This conference was organized to provide information to a general audience of biologists, physicists, radiotherapists, industrial hygiene personnel and individuals from related fields on the current ability of cytogenetic analysis to provide estimates of radiation dose in cases of occupational or environmental exposure. There is a growing interest in Spain in biological dosimetry because of the increased use of radiation sources for medical and occupational uses, and with this the anticipated and actual increase in numbers of overexposure. The traveler delivered the introductory lecture on Biological Dosimetry: Mechanistic Concepts'' that was intended to provide a framework by which the more applied lectures could be interpreted in a mechanistic way. A second component of the trip was to provide advice with regard to several recent cases of overexposure that had been or were being assessed by the Radiopathology and Radiotherapy Department of the Hospital General Gregorio Maranon'' in Madrid. The traveler had provided information on several of these, and had analyzed cells from some exposed or purportedly exposed individuals. The members of the biological dosimetry group were referred to individuals at REACTS at Oak Ridge Associated Universities for advice on follow-up treatment.

  10. Three-Dimensional (X,Y,Z) Deterministic Analysis of the PCA-Replica Neutron Shielding Benchmark Experiment using the TORT-3.2 Code and Group Cross Section Libraries for LWR Shielding and Pressure Vessel Dosimetry

    Science.gov (United States)

    Pescarini, Massimo; Orsi, Roberto; Frisoni, Manuela

    2016-02-01

    The PCA-Replica 12/13 (H2O/Fe) neutron shielding benchmark experiment was analysed using the ORNL TORT-3.2 3D SN code. PCA-Replica, specifically conceived to test the accuracy of nuclear data and transport codes employed in LWR shielding and radiation damage calculations, reproduces a PWR ex-core radial geometry with alternate layers of water and steel including a PWR pressure vessel simulator. Three broad-group coupled neutron/photon working cross section libraries in FIDO-ANISN format with the same energy group structure (47 n + 20 γ) and based on different nuclear data were alternatively used: the ENEA BUGJEFF311.BOLIB (JEFF-3.1.1) and BUGENDF70.BOLIB (ENDF/B-VII.0) libraries and the ORNL BUGLE-96 (ENDF/B-VI.3) library. Dosimeter cross sections derived from the IAEA IRDF-2002 dosimetry file were employed. The calculated reaction rates for the Rh-103(n,n')Rh-103 m, In-115(n,n')In-115m and S-32(n,p)P-32 threshold activation dosimeters and the calculated neutron spectra are compared with the corresponding experimental results.

  11. In vivo photoacoustic monitoring of photosensitizer in skin: application to dosimetry for antibacterial photodynamic treatment

    Science.gov (United States)

    Hirao, Akihiro; Sato, Shunichi; Saitoh, Daizoh; Shinomiya, Nariyoshi; Ashida, Hiroshi; Obara, Minoru

    2009-02-01

    To obtain efficient antibacterial photodynamic effect in traumatic injuries such as burns, depth-resolved dosimetry of photosensitizer is required. In this study, we performed dual-wavelength photoacoustic (PA) measurement for rat burned skins injected with a photosensitizer. As a photosensitizer, methylene blue (MB) or porfimer sodium was injected into the subcutaneous tissue in rats with deep dermal burn. The wound was irradiated with red (665 nm or 630 nm) pulsed light to excite photosensitizers and green (532 nm) pulsed light to excite blood in the tissue; the latter signal was used to eliminate blood-associated component involved in the former signal. Acoustic attenuation was also compensated from the photosensitizer-associated PA signals. These signal processing was effective to obtain high-contrast image of a photosensitizer in the tissue. Behaviors of MB and porfimer sodium in the tissue were compared.

  12. Dosimetry Service

    CERN Multimedia

    Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter every month at least once and preferably during the first week. A regular read-out is indispensable in order to ensure a periodic monitoring of the personal dose. You should read your dosimeter even if you have not visited the controlled areas. If you still have the old dosimeter (film badge), please send it immediately for evaluation to us (Bdg 24 E-011). After January 2005 there will be no developing process for the old film system. Information for Contractors: Please remember also to bring the form ‘Confirm Reception of a CERN Dosimeter' signed with ‘Feuille d'enregistrement du CERN'. Without these forms the dosimeter cannot be assigned. Thank you for your cooperation. Dosimetry Service Tel 767 2155 http://cern.ch/rp-dosimetry

  13. Development of Kilovoltage X-ray Dosimetry Methods and Their Application to Cone Beam Computed Tomography

    Science.gov (United States)

    Lawless, Michael J.

    The increase in popularity of pre-treatment imaging procedures in radiation therapy, such as kilovoltage cone beam computed tomography (CBCT), has been accompanied by an increase in the dose delivered to the patient from these imaging procedures. The measurement of dose from CBCT scans is complicated, as currently available kilovoltage dosimetry protocols are based on air-kerma standards and radiation detectors exhibit large energy responses at the low photon energies used in the imaging procedures. This work aims to provide the tools and methodology needed to measure the dose from these scans more accurately and precisely. Through the use of a validated Monte Carlo (MC) model of the moderately filtered (M-series) x-ray beams at the University of Wisconsin Accredited Dosimetry Calibration Laboratory, dose-to-water rates were obtained in a water phantom for the M-series x-ray beams with tube potentials from 40-250 kVp. The resulting dose-to-water rates were consistent with previously established methods, but had significantly reduced uncertainties. While detectors are commonly used to measure dose in phantom, previous investigations of the energy response of common detectors in the kilovoltage energy range have been limited to in-air geometries. The newly determined dose-to-water rates were used to characterize the in-phantom energy and depth response of thermoluminescent dosimeters and ionization chambers. When compared to previous investigations of the in-air detector response, the impact of scatter and absorption of the photon beam by the water medium was found to have a significant impact on the response of certain detectors. The dose to water in the NIST-traceable M-series x-ray beams was transferred to clinical CBCT beams and the resulting doses agreed with other dose-to-water measurement techniques. The dose to water in the CBCT beams was used to characterize the energy and depth responses of a number of detectors. The energy response in the CBCT beams agreed

  14. Modeling physicochemical interactions affecting in vitro cellular dosimetry of engineered nanomaterials: application to nanosilver

    Science.gov (United States)

    Mukherjee, Dwaipayan; Leo, Bey Fen; Royce, Steven G.; Porter, Alexandra E.; Ryan, Mary P.; Schwander, Stephan; Chung, Kian Fan; Tetley, Teresa D.; Zhang, Junfeng; Georgopoulos, Panos G.

    2014-10-01

    Engineered nanomaterials (ENMs) possess unique characteristics affecting their interactions in biological media and biological tissues. Systematic investigation of the effects of particle properties on biological toxicity requires a comprehensive modeling framework which can be used to predict ENM particokinetics in a variety of media. The Agglomeration-diffusion-sedimentation-reaction model (ADSRM) described here is stochastic, using a direct simulation Monte Carlo method to study the evolution of nanoparticles in biological media, as they interact with each other and with the media over time. Nanoparticle diffusion, gravitational settling, agglomeration, and dissolution are treated in a mechanistic manner with focus on silver ENMs (AgNPs). The ADSRM model utilizes particle properties such as size, density, zeta potential, and coating material, along with medium properties like density, viscosity, ionic strength, and pH, to model evolving patterns in a population of ENMs along with their interaction with associated ions and molecules. The model predictions for agglomeration and dissolution are compared with in vitro measurements for various types of ENMs, coating materials, and incubation media, and are found to be overall consistent with measurements. The model has been implemented for an in vitro case in cell culture systems to inform in vitro dosimetry for toxicology studies, and can be directly extended to other biological systems, including in vivo tissue sub-systems by suitably modifying system geometry.

  15. On application of low doses from beta radiation source in OSL retrospective dosimetry

    Science.gov (United States)

    Przegietka, K.; Chruscinska, A.

    2014-11-01

    The paper reports on three levels of dose rates obtainable from single beta source: (133±3) mGy/s, (17.8±0.3) mGy/s and (1.94±0.04) mGy/s, as calibrated for quartz sand grains. These values were achieved for different attenuation stages of beta radiation emitted by standard 90Sr/90Y source with the nominal activity of 1.48 GBq attached to an automatic luminescence reader. Lower dose rates give opportunity for exact dosing, which is especially required in luminescence dating applied to young samples as well as in environmental dosimetry. Moreover new method for determining time lag in opening the source in the Riso beta irradiator is presented. This allowed to resolve the contradiction appearing in the literature. The time delay was found to be (0.15±0.01) s per single irradiation. For improving accuracy the dose rate correction is suggest to be taken into account for irradiations shorter than 30 s.

  16. ESR-dosimetry in thermal and epithermal neutron fields for application in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, Tobias

    2016-01-22

    Dosimetry is essential for every form of radiotherapy. In Boron Neutron Capture Therapy (BNCT) mixed neutron and gamma fields have to be considered. Dose is deposited in different neutron interactions with elements in the penetrated tissue and by gamma particles, which are always part of a neutron field. The therapeutic dose in BNCT is deposited by densely ionising particles, originating from the fragmentation of the isotope boron-10 after capture of a thermal neutron. Despite being investigated for decades, dosimetry in neutron beams or fields for BNCT remains complex, due to the variety in type and energy of the secondary particles. Today usually ionisation chambers combined with metal foils are used. The applied techniques require extensive effort and are time consuming, while the resulting uncertainties remain high. Consequently, the investigation of more effective techniques or alternative dosimeters is an important field of research. In this work the possibilities of ESR-dosimeters in those fields have been investigated. Certain materials, such as alanine, generate stable radicals upon irradiation. Using Electron Spin Resonance (ESR) spectrometry the amount of radicals, which is proportional to absorbed dose, can be quantified. Different ESR detector materials have been irradiated in the thermal neutron field of the research reactor TRIGA research reactor in Mainz, Germany, with five setups, generating different secondary particle spectra. Further irradiations have been conducted in two epithermal neutron beams. The detector response, however, strongly depends on the dose depositing particle type and energy. It is hence necessary to accompany measurements by computational modelling and simulation. In this work the Monte Carlo code FLUKA was used to calculate absorbed doses and dose components. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using amorphous track models. For the simulation, detailed models of

  17. The ratio of stopping powers of water and air for dosimetry applications in tumor therapy

    Science.gov (United States)

    Paul, Helmut; Geithner, Oksana; Jäkel, Oliver

    2007-03-01

    For the purpose of dosimetry in radiation therapy, one uses air filled ionization chambers and converts the reading to absorbed dose in water which is the standard reference medium. For this conversion, an accurate knowledge of the stopping powers of water and air is required. Since experimental data in the required energy range are almost non-existent, one has to rely on semi-empirical or theory-based stopping power tables. For the example of carbon ions of 400 MeV/nucleon, we calculate the stopping power ratio Sw,air as a function of depth in water, using Monte Carlo program SHIELD-HIT v.2 that takes the production of secondary particles by nuclear reactions into account. We find that the result is very nearly the same as the simple ratio of stopping powers of water and air, obtained using the simplest Bethe theory, and that this ratio is essentially determined by the mean ionization potentials Iwater and Iair. We find that the I values for water and air used in Reports 49 and 73 of the International Commission on Radiation Units and Measurements (ICRU) differ from each other, which leads to a peculiar shape of the curve Sw,air if the tables from Report 49 are used for p and α fragments and those from Report 73 for the rest. If a single set of I values is used instead, the curve is monotonely rising, and the absolute value is smaller. In view of newer published results, we suggest that the values Iwater and Iair should probably be increased from those given in the ICRU Reports. However, at the energy considered, all our results for Sw,air fit into the range 1.13 ± 0.02 determined in the IAEA Code of Practice.

  18. Application of a canine 238Pu dosimetry model to human bioassay data

    Energy Technology Data Exchange (ETDEWEB)

    Hickman, Jr., A. W. [Florida Univ., Gainesville, FL (United States)

    1991-08-01

    Associated with the use of 2238Pu in thermoelectric power sources for space probes and power supplies for cardiac devices is the potential for human exposure to 238Pu, primarily by inhalation. In the event of human internal exposure, a means is needed for assessing the level of intake and calculating radiation doses. Several bioassay/dosimetry models have been developed for 239Pu. However, results from studies with laboratory animals have indicated that the biokinetics, and therefore the descriptive models, of 238Pu are significantly different from those for 239Pu. A canine model accounting for these differences has been applied in this work to urinary excretion data from seven humans occupationally exposed to low levels of an insoluble 238Pu compound. The modified model provides a good description of the urinary excretion kinetics observed in the exposed humans. The modified model was also used to provide estimates of the initial intakes of 238Pu for the seven individuals; these estimates ranged from 4.5 nCi (170 Bq) to 87 nCi (3200 Bq). Autopsy data on the amount and distribution of 238Pu retained in the organs may be used in the future to validate or refute both these estimates and the assumptions used to formulate the human model. Modification of the human model to simulate an injection exposure to 239Pu gave patterns of retention in the organs and urinary excretion comparable to those seen previously in humans; further modification of the model using fecal data (unavailable for the subjects of this study) is indicated.

  19. Prestressed-concrete pressure vessels and their applicability to advanced-energy-system concepts

    Energy Technology Data Exchange (ETDEWEB)

    Naus, D.J

    1983-01-01

    Prestressed concrete pressure vessels (PCPVs) are, in essence, spaced steel structures since their strength is derived from a multitude of steel elements made up of deformed reinforcing bars and prestressing tendons which are present in sufficient quantities to carry tension loads imposed on the vessel. Other major components of a PCPV include the concrete, liner and cooling system, and insulation. PCPVs exhibit a number of advantages which make them ideally suited for application to advanced energy concepts: fabricability in virtually any size and shape using available technology, improved safety, reduced capital costs, and a history of proven performance. PCPVs have many applications to both nuclear- and non-nuclear-based energy systems concepts. Several of these concepts will be discussed as well as the research and development activities conducted at ORNL in support of PCPV development.

  20. Development of optically stimulated luminescence techniques using natural minerals and ceramics, and their application to retrospective dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Boetter-Jensen, L

    2000-09-01

    This thesis summarises research and development of optically stimulated luminescence (OSL) and its applications by the author at Risoe National Laboratory, up to 1999. These developments have been directed primarily at retrospective accident dosimetry and luminescence dating. Experimental investigations include the studies of OSL properties of the natural minerals quartz and feldspars and the artificial materials porcelain and aluminium oxide (Al{sub 2}O{sub 3}). Blue light emitting diodes and infrared laser diodes are shown to provide simple and practical alternatives to broad-band light and visible laser stimulation. The development of OSL apparatus designed for the rapid measurement of single grains of phosphors also opens up a new area of luminescence measurement, allowing the detailed examination of dose distributions within a multiple-grain sample. This is of particular importance to the studies of incompletely reset geological sediments, and to accident dosimetry measurements using unheated materials. Al{sub 2}O{sub 3}:C single crystals are tested as environmental OSL dosemeters for assessing both the natural background photon radiation dose rates in the field and the natural dose rates inside bricks collected for accident dose evaluation. Environmental doses of the order of few {mu}Gy are measured with high precision. UV photo-stimulated luminescence spectra obtained from porcelain samples are used to confirm that the main component responsible for the OSL signal from porcelain is Al{sub 2}O{sub 3}. OSL single-aliquot regenerative-dose (SAR) techniques are used with quartz extracted from Chernobyl bricks to determine the accrued dose after the accident. This has improved the measurement precision significantly, from about 5-6 % using traditional methods to now less than 2 %. Depth-dose profiles measured in Chernobyl bricks are compared with those obtained in the laboratory using different gamma sources and these comparisons show that the average energy of

  1. Measurements of planar and depth dose distributions using a scintillating fiber-optic image sensor system for dosimetry in radiotherapeutic applications

    Science.gov (United States)

    Shin, Sang Hun; Yoo, Wook Jae; Seo, Jeong Ki; Han, Ki-Tek; Jeon, Dayeong; Jang, Kyoung Won; Sim, Hyeok In; Cho, Seunghyun; Lee, Bongsoo

    2013-03-01

    We developed a scintillating fiber-optic image sensor system (SFISS) using square plastic optical fibers (POFs), a scintillating film, a right-angle mirror, and a complementary metal-oxide semiconductor (CMOS) image camera for dosimetry in radiotherapeutic applications. In this study, the scintillating light images were obtained for measuring two-dimensional planar dose distributions of a 6MV photon beam in a solid-water phantom. We also measured the percentage depth doses (PDDs) of 6 and 15MV photon beams using the SFISS and compared them with those obtained using conventional dosimetry films. The proposed sensor has many advantages, such as real-time readout, high-resolution measurement, and lack of corrections for temperature, pressure, and humidity. From the results of this study, it is expected that a SFISS can be developed to accurately measure the dose distribution in a small beam field for stereotactic radiosurgery (SRS).

  2. BUGJEFF311.BOLIB (JEFF-3.1.1 and BUGENDF70.BOLIB (ENDF/B-VII.0 – Generation Methodology and Preliminary Testing of two ENEA-Bologna Group Cross Section Libraries for LWR Shielding and Pressure Vessel Dosimetry

    Directory of Open Access Journals (Sweden)

    Pescarini Massimo

    2016-01-01

    Full Text Available Two broad-group coupled neutron/photon working cross section libraries in FIDO-ANISN format, dedicated to LWR shielding and pressure vessel dosimetry applications, were generated following the methodology recommended by the US ANSI/ANS-6.1.2-1999 (R2009 standard. These libraries, named BUGJEFF311.BOLIB and BUGENDF70.BOLIB, are respectively based on JEFF-3.1.1 and ENDF/B-VII.0 nuclear data and adopt the same broad-group energy structure (47 n + 20 γ of the ORNL BUGLE-96 similar library. They were respectively obtained from the ENEA-Bologna VITJEFF311.BOLIB and VITENDF70.BOLIB libraries in AMPX format for nuclear fission applications through problem-dependent cross section collapsing with the ENEA-Bologna 2007 revision of the ORNL SCAMPI nuclear data processing system. Both previous libraries are based on the Bondarenko self-shielding factor method and have the same AMPX format and fine-group energy structure (199 n + 42 γ as the ORNL VITAMIN-B6 similar library from which BUGLE-96 was obtained at ORNL. A synthesis of a preliminary validation of the cited BUGLE-type libraries, performed through 3D fixed source transport calculations with the ORNL TORT-3.2 SN code, is included. The calculations were dedicated to the PCA-Replica 12/13 and VENUS-3 engineering neutron shielding benchmark experiments, specifically conceived to test the accuracy of nuclear data and transport codes in LWR shielding and radiation damage analyses.

  3. The application of polymer gel dosimeters to dosimetry for targeted radionuclide therapy

    Science.gov (United States)

    Gear, J. I.; Flux, G. D.; Charles-Edwards, E.; Partridge, M.; Cook, G.; Ott, R. J.

    2006-07-01

    irradiated gels. Curve fits to the calibration data followed a single exponential function. The correlation coefficients for internally and externally irradiated gels were 0.991 and 0.985, respectively. With the ability to accurately calibrate internally dosed polymer gels, this technology shows promise as a means to evaluate dosimetry methods, particularly in cases of non-uniform uptake of a radionuclide.

  4. Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV.

    Science.gov (United States)

    Ehringfeld, Christian; Schmid, Susanne; Poljanc, Karin; Kirisits, Christian; Aiginger, Hannes; Georg, Dietmar

    2005-01-21

    The purpose of this study was to investigate the dosimetric characteristics (energy dependence, linearity, fading, reproducibility, etc) of MOSFET detectors for in vivo dosimetry in the kV x-ray range. The experience of MOSFET in vivo dosimetry in a pre-clinical study using the Alderson phantom and in clinical practice is also reported. All measurements were performed with a Gulmay D3300 kV unit and TN-502RDI MOSFET detectors. For the determination of correction factors different solid phantoms and a calibrated Farmer-type chamber were used. The MOSFET signal was linear with applied dose in the range from 0.2 to 2 Gy for all energies. Due to fading it is recommended to read the MOSFET signal during the first 15 min after irradiation. For long time intervals between irradiation and readout the fading can vary largely with the detector. The temperature dependence of the detector signal was small (0.3% degrees C(-1)) in the temperature range between 22 and 40 degrees C. The variation of the measuring signal with beam incidence amounts to +/-5% and should be considered in clinical applications. Finally, for entrance dose measurements energy-dependent calibration factors, correction factors for field size and irradiated cable length were applied. The overall accuracy, for all measurements, was dominated by reproducibility as a function of applied dose. During the pre-clinical in vivo study, the agreement between MOSFET and TLD measurements was well within 3%. The results of MOSFET measurements, to determine the dosimetric characteristics as well as clinical applications, showed that MOSFET detectors are suitable for in vivo dosimetry in the kV range. However, some energy-dependent dosimetry effects need to be considered and corrected for. Due to reproducibility effects at low dose levels accurate in vivo measurements are only possible if the applied dose is equal to or larger than 2 Gy.

  5. Dosimetry in dentistry.

    Science.gov (United States)

    Asha, M L; Chatterjee, Ingita; Patil, Preeti; Naveen, S

    2015-01-01

    The purpose of this paper was to review various dosimeters used in dentistry and the cumulative results of various studies done with various dosimeters. Several relevant PubMed indexed articles from 1999 to 2013 were electronically searched by typing "dosimeters", "dosimeters in dentistry", "properties of dosimeters", "thermoluminescent and optically stimulated dosimeters", "recent advancements in dosimetry in dentistry." The searches were limited to articles in English to prepare a concise review on dental dosimetry. Titles and abstracts were screened, and articles that fulfilled the criteria of use of dosimeters in dental applications were selected for a full-text reading. Article was divided into four groups: (1) Biological effects of radiation, (2) properties of dosimeters, (3) types of dosimeters and (4) results of various studies using different dosimeters. The present review on dosimetry based on various studies done with dosimeters revealed that, with the advent of radiographic technique the effective dose delivered is low. Therefore, selection of radiological technique plays an important role in dental dose delivery.

  6. Impact of source position on high-dose-rate skin surface applicator dosimetry.

    Science.gov (United States)

    Jeong, Jeho; Barker, Christopher A; Zaider, Marco; Cohen, Gil'ad N

    2016-01-01

    Skin surface dosimetric discrepancies between measured and treatment planning system predicted values were traced to source position sag inside the applicator and to source transit time. We quantified their dosimetric impact and propose corrections for clinical use. We measured the dose profiles from the Varian Leipzig-style high-dose-rate (HDR) skin applicator, using EBT3 film, photon diode, and optically stimulated luminescence dosimeter for three different GammaMedplus HDR afterloaders. The measured dose profiles at several depths were compared with BrachyVision Acuros calculated profiles. To assess the impact of the source sag, two different applicator orientations were considered. The dose contribution during source transit was assessed by comparing diode measurements using an HDR timer and an electrometer timer. Depth doses measured using the three dosimeters were in good agreement, but were consistently higher than the Acuros dose calculations. Measurements with the applicator face up were significantly (exceeding 10%) lower than those in the face down position, due to source sag inside the applicator. Based on the inverse square law, the effective source sag was evaluated to be about 0.5 mm from the planned position. The additional dose during source transit was evaluated to be about 2.8% for 30 seconds of treatment with a 40700 U (10 Ci) source. With a very short source-to-surface distance, the small source sag inside the applicator has a significant dosimetric impact. This effect is unaccounted for in the vendor's treatment planning template and should be considered before the clinical use of the applicator. Further investigation of other applicators with large source lumen diameter may be warranted. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  7. A Monte Carlo dosimetry study using Henschke applicator for cervical brachytherapy

    Science.gov (United States)

    Yu, Pei-Chieh; Chao, Tsi-Chian; Lee, Chung-Chi; Wu, Ching-Jung; Tung, Chuan-Jong

    2010-07-01

    In recent years the Henschke applicator has been widely used for gynecologic patients treated by brachytherapy in Taiwan. However, the commercial brachytherapy planning system did not properly evaluate the dose perturbation caused by the Henschke applicator. Since the European Society for Therapeutic Radiology and Oncology advised that the effect of source shielding should be incorporated into the brachytherapy planning system, it required calculation and comparison of the dose distribution around the applicator. This study used the Monte Carlo MCNP code to simulate the dose distribution in a water phantom that contained the Henschke applicator with one tandem and two ovoids. Three dwell positions of a high dose rate 192Ir source were simulated by including and excluding the applicator. The mesh tally option of the MCNP was applied to facilitate the calculation of a large number of tallies in the phantom. The voxel size effect and the charge particle equilibrium were studied by comparing the results calculated with different tally options. The calculated results showed that the brachytherapy planning system overestimated the rectal dose and that the shielding material in the applicator contributed more than 40% to the rectal dose.

  8. Evaluation of Mechanical Properties and Medical Applications of Polycaprolactone Small Diameter Artificial Blood Vessels

    Directory of Open Access Journals (Sweden)

    Mahnazsadat Mirbagheri

    2017-03-01

    Full Text Available Increasing the cardiovascular diseases and decreasing the possibility of autograft surgery are important factors that cause the choice of artificial vascular graft as an alternative treatment method. In this regard, producing artificial grafts similar to natural vessels is an important purpose that has long been followed as a gold standard by many researchers worldwide. In addition, mechanical properties including strength, long patency, bio-compatibility and hydrophobicity are necessary properties to achieve ideal vascular grafts. Hence there are various factors such as polymer type and preparation methods, which contribute to suitable mechanical properties. The electrospinning as an optimized method on one side and biocompatible, degradable and semicrystalline polycaprolactone (PCL on the other side are used for their acceptable mechanical properties to manufacture synthetic vessels. In this study, PCL vascular grafts have been reviewed and a wide range of parameters affecting the improvement of mechanical properties and their performance have been described along with clinical applications. Therefore, by investigating and comparing single and composite PCL vascular grafts, we achieved acceptable results in the field of cell growth and adhesion as well as implanting grafts in animals such as rat and rabbit. By reviewing other studies, it was revealed that synthetic composite vessels made of PCL and natural polymers such as collagen and chitosan and synthetic polymers such as polyurethane (PU for long patency and acceptable cell adhesion have shown good clinical results.

  9. Technical Note: Dosimetry of Leipzig and Valencia applicators without the plastic cap

    Energy Technology Data Exchange (ETDEWEB)

    Granero, D., E-mail: dgranero@eresa.com [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Candela-Juan, C. [National Dosimetry Centre (CND), Instituto Nacional de Gestión Sanitaria, Valencia 46009 (Spain); Vijande, J. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and Instituto de Física Corpuscular (UV-CSIC), Burjassot 46100 (Spain); Ballester, F. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and Instituto de Fisica Corpuscular (UV-CSIC), Burjassot 46100 (Spain); Perez-Calatayud, J. [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and Department of Radiotherapy, Clínica Benidorm, Benidorm 03501 (Spain); Jacob, D.; Mourtada, F. [Department of Radiation Oncology, Helen F. Graham Cancer Center, Christiana Care Health System, Newark, Delaware 19713 (United States)

    2016-05-15

    Purpose: High dose rate (HDR) brachytherapy for treatment of small skin lesions using the Leipzig and Valencia applicators is a widely used technique. These applicators are equipped with an attachable plastic cap to be placed during fraction delivery to ensure electronic equilibrium and to prevent secondary electrons from reaching the skin surface. The purpose of this study is to report on the dosimetric impact of the cap being absent during HDR fraction delivery, which has not been explored previously in the literature. Methods: GEANT4 Monte Carlo simulations (version 10.0) have been performed for the Leipzig and Valencia applicators with and without the plastic cap. In order to validate the Monte Carlo simulations, experimental measurements using radiochromic films have been done. Results: Dose absorbed within 1 mm of the skin surface increases by a factor of 1500% for the Leipzig applicators and of 180% for the Valencia applicators. Deeper than 1 mm, the overdosage flattens up to a 10% increase. Conclusions: Differences of treating with or without the plastic cap are significant. Users must check always that the plastic cap is in place before any treatment in order to avoid overdosage of the skin. Prior to skin HDR fraction delivery, the timeout checklist should include verification of the cap placement.

  10. Development and application of an initial quality assurance program for dosimetry at GSI

    Energy Technology Data Exchange (ETDEWEB)

    Heeg, P.; Hartmann, G.; Jaekel, O.; Karger, C.; Kriessbach, A. [DKFZ Heidelberg (Germany); Schardt, D. [GSI Darmstadt (Germany)

    1997-09-01

    c set of test procedures has been developed for dosimetric quality inspections at the heavy ion therapy facility at GSI. In some cases new test principles had to be established to meet the requirements at the heavy ion beam. As a first application the acceptance test has been carried out during the technical commissioning of the facility. (orig.)

  11. Dosimetry for radiation processing

    DEFF Research Database (Denmark)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both...... and sterilization dosimetry, optichromic dosimeters in the shape of small tubes for food processing, and ESR spectroscopy of alanine for reference dosimetry. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading...

  12. ESR dosimetry: achievements and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Baffa, O., E-mail: baffa@usp.br [Universidade de Sao Paulo, Departamento de Fisica, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, Sao Paulo (Brazil)

    2015-10-15

    Full text: Electron Spin Resonance (ESR), also known as Electron Paramagnetic Resonance (EPR) and more recently as Electron Magnetic Resonance (Emr), is a spectroscopy technique able to detect unpaired electrons such as those created by the interaction ionizing radiation with matter. When the unpaired electrons created by ionizing radiation are stable over some reasonable time, ESR can be used to measure the radiation dose deposited in the material under study. In principle, any insulating material that satisfies this requisite can be used as a dosimeter. ESR has been used in retrospective dosimetry in case of radiological accidents using natural constituents of human body such as teeth, bones and nails as well as fortuitous materials as sugar, sweeteners and plastics. When using teeth the typical detected dose is 0.5 Gy for, for X-Band spectrometers (9 GHz) and even lower doses if higher frequency spectrometers are used. Clinical dosimetry is another area of potential use of this dosimetric modality. In this application the amino acid alanine has been proposed and being used. Alanine dosimeters are very easy to prepare and require no complicated treatments for use. Alanine/ESR dosimetry satisfies many of the required properties for clinical applications such as water equivalent composition, independence of response for the energy range used in therapy and high precision. Other organic materials such as ammonium tartrate are being investigated to increase the sensitivity of ESR for clinical applications. Finally, industrial applications can also benefit from this dosimetry. The challenges to expand applications, the number of users and research groups of ESR dosimetry will be discussed. (Author)

  13. Accelerator mass spectrometry in the biomedical sciences: applications in low-exposure biomedical and environmental dosimetry

    Science.gov (United States)

    Felton, J. S.; Turteltaub, K. W.; Vogel, J. S.; Balhorn, R.; Gledhill, B. L.; Southon, J. R.; Caffee, M. W.; Finkel, R. C.; Nelson, D. E.; Proctor, I. D.; Davis, J. C.

    1990-12-01

    We are utilizing accelerator mass spectrometry as a sensitive detector for tracking the disposition of radioisotopically labeled molecules in the biomedical sciences. These applications have shown the effectiveness of AMS as a tool to quantify biologically important molecules at extremely low levels. For example, AMS is being used to determine the amount of carcinogen covalently bound to animal DNA (DNA adduct) at levels relevent to human exposure. Detection sensitivities are 1 carcinogen molecule bound in 1011 to 1012 DNA bases, depending on the specific activity of the radiolabeled carcinogen. Studies have been undertaken in our laboratory utilizing heterocyclic amine food-borne carcinogens and 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), a potent environmental carcinogen, to study the metabolism of carcinogens at low doses. In addition, AMS is being used to detect the presence of rare proteins (mutant forms of protamine) in human sperm. Approximately l per 106 sperm analyzed contain the rare form of the protamine. Protamine isolated from this small number of cells is being analyzed by AMS, following 14C labeling. Thus, AMS can be used to verify the identity of an extremely small amount of biological material. Furthermore, an additional improvement of 2 orders of magnitude in the sensitivity of biomédical tracer studies is suggested by preliminary work with bacterial hosts depleted in radiocarbon. Other problems in the life sciences where detection sensitivity or sample sizes are limitations should also benefit from AMS. Studies are underway to measure the molecular targeting of cancer chemotherapeutics in human tissue and to pursue applications for receptor biology. We are also applying other candidate isotopes, such as 3H (double labeling with 14C) and 41Ca (bone absorption) to problems in biology. The detection of 36Cl and 26Al have applications for determination of human neutron exposure and understanding neurological toxicity, respectively. The results

  14. Manufacturing polycrystalline pellets of natural quartz for applications in thermoluminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho Junior, Alvaro Barbosa de; Khoury, Helen Jamil [Federal University of Pernambuco (UFPE), Recife, PE (Brazil). Department of Nuclear Energy; Barros, Thiago Fernandes; Guzzo, Pedro Luiz [Federal University of Pernambuco (UFPE), Recife, PE (Brazil). Department of Mining Engineering

    2012-07-15

    This paper describes the manufacturing process of quartz-pellets and shows their potential use as thermoluminescence dosimeters (TLD) for those applications where low-levels of ionising radiation are present. Two batches of cold-pressed pellets were produced and their resistance were evaluated by vibration tests and weight-loss measurements. The batch manufactured with 75 Multiplication-Sign 150 Micro-Sign m particles showed enough resistance to be employed as TLD. The dosimetric properties of the 310 Degree-Sign C peak appearing in the glow curves of these pellets were characterized together with commercial TLD-100 units using {gamma}- and X-ray beams with different energies. The uncertainties related to reproducibility and stability of the TL signal were better than 10%. The sensitivity and the linearity of the TL response of quartz-pellets were better than that measured for TLD-100 for doses ranging from 0.5 to 200mGy. The energy dependence of the quartz-pellets was higher than that of TLD-100 but it cannot be considered a restriction to their use in clinical procedures and industrial applications. (author)

  15. Unique identification code for medical fundus images using blood vessel pattern for tele-ophthalmology applications.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore; Sharma, Dilip Kumar

    2016-10-01

    Identification of fundus images during transmission and storage in database for tele-ophthalmology applications is an important issue in modern era. The proposed work presents a novel accurate method for generation of unique identification code for identification of fundus images for tele-ophthalmology applications and storage in databases. Unlike existing methods of steganography and watermarking, this method does not tamper the medical image as nothing is embedded in this approach and there is no loss of medical information. Strategic combination of unique blood vessel pattern and patient ID is considered for generation of unique identification code for the digital fundus images. Segmented blood vessel pattern near the optic disc is strategically combined with patient ID for generation of a unique identification code for the image. The proposed method of medical image identification is tested on the publically available DRIVE and MESSIDOR database of fundus image and results are encouraging. Experimental results indicate the uniqueness of identification code and lossless recovery of patient identity from unique identification code for integrity verification of fundus images. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Monte Carlo dosimetry in simple geometries with interfaces: applications in radiotherapy; Dosimetria Monte Carlo en geometrias simples con interfases: aplicaciones en radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E.L

    2004-07-01

    In the last decade, dosimetry has evolved in an accelerated way due in part, to the development of new techniques and advances in instruments manufactured for several applications in Medical Physics. In order to improve achievements gotten with the use of radiation sources for therapeutic use, a guessed right dosimetry must be done and clinical data must be explained with the aid of investigation and supported with scientific bases. In this context, Monte Carlo (MC) method used to simulate radiation transport in materials, contribute with extensive knowledge and extremely useful information to that objective. MC dosimetry has some advantages over experimental and analytical dosimetry but it also has limitations. Maybe the most important is the computer time required to reach to an acceptable uncertainty level in a complex problem. Though this restrictive factor, a right application of MC simulation of radiation transport is a useful, reliable and versatile instrument for dosimetric calculations. From our point of view, the problem of heterogeneities in the sources or in the treatment targets in radiotherapy is of great importance, and this is the principal question to study aboard in this work. We use the MC simulation code Penelope to calculate some dosimetric quantities.The cases we study involve dosimetric aspects of different geometric distributions of radionuclides where interfaces are evident and must be taken into account. This work is divided in five chapters. In the first chapter we give a succinctly description of MC codes for simulation of the transport of particles in a medium and we describe the code Penelope. In chapter two, we study spherical distributions of radionuclides and the effect that interfaces in the target have in the dose received by the tumor. Specifically we study the application of radiocolloids with {sup 186} Re and {sup 32} P to treat homogeneous and nonhomogeneous cystic craniopharyngioma. Chapter three is dedicated to study plane

  17. MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

    Energy Technology Data Exchange (ETDEWEB)

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  18. First application of total skin electron beam irradiation in Greece: setup, measurements and dosimetry.

    Science.gov (United States)

    Platoni, K; Diamantopoulos, S; Panayiotakis, G; Kouloulias, V; Pantelakos, P; Kelekis, N; Efstathopoulos, E

    2012-04-01

    Total Skin Electron Beam (TSEB) irradiation is considered as the treatment of choice for cutaneous T-cell lymphoma internationally, for either curative purposes or palliative care. An attempt for the first application of this external radiation therapy technique in Greece took place at the Radiation Therapy Unit of 2(nd) Department of Radiology of University of Athens at University General Hospital "Attikon". TSEB modality was developed on a linear accelerator VARIAN Clinac 2100C. To create a uniform and sufficiently large field (≈200 cm × 80 cm) at SSD=380 cm, two symmetrical 6 MeV electron beams are combined with 17.5° tilts concerning the horizontal direction. An immobilization system was constructed to support patient during treatment and to modulate the composite electron field. Irradiation procedure demands a standing patient that takes, in total, six treatment positions. For the confirmation of treatment suitability and the determination of physical features of the clinical electron field, specific measurements were carried out using a parallel-plate ionization chamber and TLDs at water equivalent plastic and anthropomorphic phantoms. Measurements at the referred conditions showed a homogeneous total field with intensity variation of ±2% in the longitudinal axis and ±4% at horizontal axis. The mean energy of the composite field (E¯(o)) is 3.4 MeV, the most probable energy (E(p,0)) is 4.4 MeV and the half-value depth in water (R(50)) is 1.5 g/cm(2). The maximum X-ray background of the TSEB field is 2.1% at head and feet. The above results lead us to conclude that TSEB treatment using "Six-dual-field" technique can be applied in our department safely. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Hybrid nanostructured thin-films by PLD for enhanced field emission performance for radiation micro-nano dosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Manikandan, E., E-mail: maniphysics@gmail.com [UNESCO-UNISA AFNET in Nanosciences/Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), Materials Research Department, iThemba LABS–National Research Foundation (NRF), 1 Old Faure Road, Somerset West, PO Box 722, Western Cape (South Africa); Materials Science Group (MSG), Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam 603102 (India); Corrosion Science and Technology Group, Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam 603102 (India); Sree Balaji Medical College & Hospital (SBMCH), Bharath University, Chrompet, Chennai 600044 (India); Kennedy, J. [UNESCO-UNISA AFNET in Nanosciences/Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), Materials Research Department, iThemba LABS–National Research Foundation (NRF), 1 Old Faure Road, Somerset West, PO Box 722, Western Cape (South Africa); The MacDiarmid Institute for Advanced Materials and Nanotechnology (New Zealand); Kavitha, G. [UNESCO-UNISA AFNET in Nanosciences/Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), Materials Research Department, iThemba LABS–National Research Foundation (NRF), 1 Old Faure Road, Somerset West, PO Box 722, Western Cape (South Africa); PG& Research Dept of Physics, AM Jain College Affiliated to University of Madras, Chennai 600114 (India); and others

    2015-10-25

    We report the observation of hybrid nanostructured thin-films such as diamond-like carbon (DLC) signature on the ZnO epitaxial thin-films grown onto the device silicon/quartz substrate by reactive pulsed laser deposition (r-PLD) under the argon–oxygen (Ar|O{sub 2}) ambient at 573 K. Undoped and Carbon (C) doped epitaxial ZnO thin-film layer formation is revealed by the accelerator based ion-beam analysis (IBA) technique of resonant Rutherford backscattering spectrometry (RRBS), glancing-incidence X-ray diffraction (GIXRD) pattern, micro-Raman spectroscopy (μ-RS) and field-emission (F-E) studies. The RRBS and GIXRD results show the deposition of epitaxial thin-films containing C into ZnO. The μ-RS technique is a standard nondestructive tool (NDT) for the characterization of crystalline, nano-crystalline, and amorphous carbons (a-C). As grown ZnO and C-doped ZnO thin-films μ-RS result reveal the doping effect of C-impurities that appear in the form of DLC evident from Raman peaks at 1357 and 1575 cm{sup −1} along with a wurtzite structure peak at 438 cm{sup −1} with E{sub 2}(h) phonon of ZnO. The electron transport F-E result shows the hybrid thin-films has high conductivity than the un-doped film. Fabricated hybrid nanostructured thin-films materials could be very useful for the emerging applications of micro-nano dosimetry. - Highlights: • Observation of hybrid nanostructured diamond-like carbon (DLC) on ZnO epitaxial thin-films at 573 K. • Carbon doped epitaxial ZnO thin-film layer formation is revealed by RRBS, Micro-Raman. • Field-emission (F-E) study. • DLC formation evident from Raman peaks at 1357 and 1575 cm{sup −1} along with a wurtzite structure peak of ZnO. • The electron transport F-E result shows the hybrid thin-film has high conductivity than the undoped thin-film.

  20. Qualification of specially prepared clothing material for gamma dosimetry: applications to mixed neutron-photon radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Benabdesselam, M.; Iacconi, P.; Lapraz, D. [Nice Univ., 06 (France). LPES-CRESA; Serbat, A.; Laugier, J.; Dhermain, J. [DGA/CEB, 94, Arcueil (France)

    1996-12-31

    When an irradiation accident occurs, it is very important for medical treatment to be able to reconstruct the cartography of the dose absorbed by the irradiated person. The cotton textile `dosimetric cotton` to which an {alpha}-alumina dosimetric powder is fixed, has been devised in LPES-CRESA. It can be used to clothe persons subjected to irradiation risks. By taking a number of precautions, the dose may be determined from measurements of the thermoluminescence (TL). Some TL tests, which are meant to describe the characteristics of the dosimetric textile in various irradiation configurations, are described. In particular, it is shown that the dosimetric cotton is especially appropriate for gamma dosimetry in mixed neutron-gamma fields. It covers the field of accident dosimetry extensively and the low detection limit actually obtained is 0.10 Gy. (author).

  1. Application of a practical method for the isocenter point in vivo dosimetry by a transit signal

    Energy Technology Data Exchange (ETDEWEB)

    Piermattei, Angelo [UO di Fisica Sanitaria, Centro di Ricerca e Formazione ad Alta Tecnologia nelle Scienze Biomediche dell' Universita Cattolica Sacro Cuore, Campobasso (Italy); Fidanzio, Andrea [Istituto di Fisica, Universita Cattolica del Sacro Cuore, Rome (Italy); Azario, Luigi [Istituto di Fisica, Universita Cattolica del Sacro Cuore, Rome (Italy)] (and others)

    2007-08-21

    This work reports the results of the application of a practical method to determine the in vivo dose at the isocenter point, D{sub iso}, of brain thorax and pelvic treatments using a transit signal S{sub t}. The use of a stable detector for the measurement of the signal S{sub t} (obtained by the x-ray beam transmitted through the patient) reduces many of the disadvantages associated with the use of solid-state detectors positioned on the patient as their periodic recalibration, and their positioning is time consuming. The method makes use of a set of correlation functions, obtained by the ratio between S{sub t} and the mid-plane dose value, D{sub m}, in standard water-equivalent phantoms, both determined along the beam central axis. The in vivo measurement of D{sub iso} required the determination of the water-equivalent thickness of the patient along the beam central axis by the treatment planning system that uses the electron densities supplied by calibrated Hounsfield numbers of the computed tomography scanner. This way it is, therefore, possible to compare D{sub iso} with the stated doses, D{sub iso,TPS}, generally used by the treatment planning system for the determination of the monitor units. The method was applied in five Italian centers that used beams of 6 MV, 10 MV, 15 MV x-rays and {sup 60}Co {gamma}-rays. In particular, in four centers small ion-chambers were positioned below the patient and used for the S{sub t} measurement. In only one center, the S{sub t} signals were obtained directly by the central pixels of an EPID (electronic portal imaging device) equipped with commercial software that enabled its use as a stable detector. In the four centers where an ion-chamber was positioned on the EPID, 60 pelvic treatments were followed for two fields, an anterior-posterior or a posterior-anterior irradiation and a lateral-lateral irradiation. Moreover, ten brain tumors were checked for a lateral-lateral irradiation, and five lung tumors carried out with

  2. [Identification of perforating vessels by augmented reality: Application for the deep inferior epigastric perforator flap].

    Science.gov (United States)

    Bosc, R; Fitoussi, A; Pigneur, F; Tacher, V; Hersant, B; Meningaud, J-P

    2017-08-01

    The augmented reality on smart glasses allows the surgeon to visualize three-dimensional virtual objects during surgery, superimposed in real time to the anatomy of the patient. This makes it possible to preserve the vision of the surgical field and to dispose of added computerized information without the need to use a physical surgical guide or a deported screen. The three-dimensional objects that we used and visualized in augmented reality came from the reconstructions made from the CT-scans of the patients. These objects have been transferred through a dedicated application on stereoscopic smart glasses. The positioning and the stabilization of the virtual layers on the anatomy of the patients were obtained thanks to the recognition, by the glasses, of a tracker placed on the skin. We used this technology, in addition to the usual locating methods for preoperative planning and the selection of perforating vessels for 12 patients operated on a breast reconstruction, by perforating flap of deep lower epigastric artery. The "hands-free" smart glasses with two stereoscopic screens make it possible to provide the reconstructive surgeon with binocular visualization in the operative field of the vessels identified with the CT-scan. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Robust shape regression for supervised vessel segmentation and its application to coronary segmentation in CTA

    DEFF Research Database (Denmark)

    Schaap, Michiel; van Walsum, Theo; Neefjes, Lisan

    2011-01-01

    This paper presents a vessel segmentation method which learns the geometry and appearance of vessels in medical images from annotated data and uses this knowledge to segment vessels in unseen images. Vessels are segmented in a coarse-to-fine fashion. First, the vessel boundaries are estimated...... with multivariate linear regression using image intensities sampled in a region of interest around an initialization curve. Subsequently, the position of the vessel boundary is refined with a robust nonlinear regression technique using intensity profiles sampled across the boundary of the rough segmentation...... and using information about plausible cross-sectional vessel shapes. The method was evaluated by quantitatively comparing segmentation results to manual annotations of 229 coronary arteries. On average the difference between the automatically obtained segmentations and manual contours was smaller than...

  4. Thermoluminescence in medical dosimetry; Termoluminiscencia en dosimetria medica

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2011-10-15

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  5. [Application of right jugular vessels to build extracorporeal membrane oxygenation for treating the critically ill children].

    Science.gov (United States)

    Yan, X G; Lu, Z J; Zheng, J C; Zhang, W W; Lu, G P; Jia, B

    2016-07-01

    To summarize the experience in applying a technique of inserting a cannula through right internal jugular vein and common carotid artery to build extracorporeal membrane oxygenation (ECMO) for critically ill children. The data of critically ill patients received ECMO support through right internal jugular vein and common carotid artery between December 2011 and December 2015 from Children's Hospital of Fudan University were analyzed retrospectively.The data included diagnosis, age, body weight, time of cannula and ECMO running, complication and prognosis. In total 28 patients received ECMO support, 3 patients of post-cardiac surgery with transthoracic cannula were excluded.Twenty-five patients inserted cannula through neck vessels were enrolled, 15 boys and 10 girls, the median age was 1.8 years (range, 1 d-13 years), the median weight was 12.0 (2.8-50.0) kg.All the cannula sites were right internal jugular vein and right common carotid artery, before cannula use 5 patients had been inserted central vein tube and 3 patients with blood filter tube in right internal jugular vein, in one case cannula was applied during cardiopulmonary resuscitation.V-A ECMO had been built for all the cases successfully, the median operation time was (45±26) min.The pump flow was 80-150 ml/(kg·min), the median duration of ECMO support was 153(14-567) h. Sixteen (64%) patients weaned off ECMO successfully, 15(60%) survived to hospital discharge.About the complication of cannula, six patients developed cannula site bleeding, and two patients required re-fixation of cannula, one patient's external jugular vein had been hurt and sutured for bleeding. Application of right jugular vessels to build ECMO is easy and safe for treating the sick children. The skill should be proficient to assure ECMO run and reduce the complications.

  6. Development of Chinese reference man deformable surface phantom and its application to the influence of physique on electromagnetic dosimetry.

    Science.gov (United States)

    Yu, D; Wang, M; Liu, Q

    2015-09-07

    A reference man is a theoretical individual that represents the average anatomical structure and physiological and metabolic features of a specific group of people and has been widely used in radiation safety research. With the help of an advantage in deformation, the present work proposed a Chinese reference man adult-male polygon-mesh surface phantom based on the Visible Chinese Human segment image dataset by surface rendering and deforming. To investigate the influence of physique on electromagnetic dosimetry in humans, a series of human phantoms with 10th, 50th and 90th body mass index and body circumference percentile physiques for Chinese adult males were further constructed by deforming the Chinese reference man surface phantom. All the surface phantoms were then voxelized to perform electromagnetic field simulation in a frequency range of 20 MHz to 3 GHz using the finite-difference time-domain method and evaluate the whole-body average and organ average specific absorption rate and the ratios of absorbed energy in skin, fat and muscle to the whole body. The results indicate thinner physique leads to higher WBSAR and the volume of subcutaneous fat, the penetration depth of the electromagnetic field in tissues and standing-wave occurrence may be the influence factors of physique on electromagnetic dosimetry.

  7. Development of Chinese reference man deformable surface phantom and its application to the influence of physique on electromagnetic dosimetry

    Science.gov (United States)

    Yu, D.; Wang, M.; Liu, Q.

    2015-09-01

    A reference man is a theoretical individual that represents the average anatomical structure and physiological and metabolic features of a specific group of people and has been widely used in radiation safety research. With the help of an advantage in deformation, the present work proposed a Chinese reference man adult-male polygon-mesh surface phantom based on the Visible Chinese Human segment image dataset by surface rendering and deforming. To investigate the influence of physique on electromagnetic dosimetry in humans, a series of human phantoms with 10th, 50th and 90th body mass index and body circumference percentile physiques for Chinese adult males were further constructed by deforming the Chinese reference man surface phantom. All the surface phantoms were then voxelized to perform electromagnetic field simulation in a frequency range of 20 MHz to 3 GHz using the finite-difference time-domain method and evaluate the whole-body average and organ average specific absorption rate and the ratios of absorbed energy in skin, fat and muscle to the whole body. The results indicate thinner physique leads to higher WBSAR and the volume of subcutaneous fat, the penetration depth of the electromagnetic field in tissues and standing-wave occurrence may be the influence factors of physique on electromagnetic dosimetry.

  8. Microvega (micro Vessel for Geodetics Application): a Marine Drone for the Acquisition of Bathymetric Data for GIS Applications

    Science.gov (United States)

    Giordano, F.; Mattei, G.; Parente, C.; Peluso, F.; Santamaria, R.

    2015-04-01

    Bathymetric data are fundamental to produce navigational chart and sea-floor 3D models. They can be collected using different techniques and sensors on board of a variety of platforms, such as satellite, aircraft, ship and drone. The MicroVEGA drone is an Open Prototype of Autonomous Unmanned Surface Vessel (AUSV) conceived, designed and built to operate in the coastal areas (0-20 meters of depth), where a traditional boat is poorly manoeuvrable. It is equipped with a series of sensors to acquire the morpho-bathymetric high precision data. In this paper we presents the result of the first case study, a bathymetric survey carried out at Sorrento Marina Grande. This survey is a typical application case of this technology; the Open Prototype MicroVega has an interdisciplinary breath and it is going to be applied to various research fields. In future, it will expect to do new knowledge, new survey strategies and an industrial prototype in fiberglass.

  9. BiodosEPR-2006 Meeting: Acute dosimetry consensus committee recommendations on biodosimetry applications in events involving uses of radiation by terrorists and radiation accidents

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, George A. [U.S. Department of Health and Human Services, Office of Preparedness and Emergency Operations, 200 Independence Avenue, SW, Room 403B-1, Washington, DC 20201 (United States); Swartz, Harold M. [Dept. of Radiology and Physiology Dept., Dartmouth Medical School, HB 7785, Vail 702, Rubin 601, Hanover, NH 03755 (United States); Amundson, Sally A. [Center for Radiological Research, Columbia University Medical Center, 630 W. 168th Street, VC11-215, New York, NY 10032 (United States); Blakely, William F. [Armed Forces Radiobiology Research Inst., 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)], E-mail: blakely@afrri.usuhs.mil; Buddemeier, Brooke [Science and Technology, U.S. Department of Homeland Security, Washington, DC 20528 (United States); Gallez, Bernard [Biomedical Magnetic Resonance Unit and Lab. of Medicinal Chemistry and Radiopharmacy, Univ. Catholique de Louvain, Brussels (Belgium); Dainiak, Nicholas [Dept. of Medicine, Bridgeport Hospital, 267 Grant Street, Bridgeport, CT 06610 (United States); Goans, Ronald E. [MJW Corporation, 1422 Eagle Bend Drive, Clinton, TN 37716-4029 (United States); Hayes, Robert B. [Remote Sensing Lab., MS RSL-47, P.O. Box 98421, Las Vegas, NV 89193 (United States); Lowry, Patrick C. [Radiation Emergency Assistance Center/Training Site (REAC/TS), Oak Ridge Associated Universities, P.O. Box 117, Oak Ridge, TN 37831-0117 (United States); Noska, Michael A. [Food and Drug Administration, FDA/CDRH, 1350 Piccard Drive, HFZ-240, Rockville, MD 20850 (United States); Okunieff, Paul [Dept. of Radiation Oncology (Box 647), Univ. of Rochester, 601 Elmwood Avenue, Rochester, NY 14642 (United States); Salner, Andrew L. [Helen and Harry Gray Cancer Center, Hartford Hospital, 80 Seymour Street, Hartford, CT 06102 (United States); Schauer, David A. [National Council on Radiation Protection and Measurements, 7910 Woodmont Avenue, Suite 400, Bethesda, MD 20814-3095 (United States)] (and others)

    2007-07-15

    , USA; NCRP, 2005. Key elements of preparing emergency responders for nuclear and radiological terrorism. NCRP Commentary No. 19, Bethesda, Maryland, USA] and international [IAEA, 2005. Generic procedures for medical response during a nuclear or radiological emergency. EPR-Medical 2005, IAEA, Vienna, Austria] agencies have reviewed strategies for acute-phase biodosimetry. Consensus biodosimetric guidelines include: (a) clinical signs and symptoms, including peripheral blood counts, time to onset of nausea and vomiting and presence of impaired cognition and neurological deficits, (b) radioactivity assessment, (c) personal and area dosimetry, (d) cytogenetics, (e) in vivo electron paramagnetic resonance (EPR) and (f) other dosimetry approaches (i.e. blood protein assays, etc.). Emerging biodosimetric technologies may further refine triage and dose assessment strategies. However, guidance is needed regarding which biodosimetry techniques are most useful for different radiological scenarios and consensus protocols must be developed. The Local Organizing Committee for the Second International Conference on Biodosimetry and Seventh International Symposium on EPR Dosimetry and Applications (BiodosEPR-2006 Meeting) convened an Acute Dosimetry Consensus Committee composed of national and international experts to: (a) review the current literature for biodosimetry applications for acute-phase applications in radiological emergencies, (b) describe the strengths and weaknesses of each technique, (c) provide recommendations for the use of biodosimetry assays for selected defined radiation scenarios, and (d) develop protocols to apply these recommended biological dosimetry techniques with currently available supplies and equipment for first responders. The Acute Dosimetry Consensus Committee developed recommendations for use of a prioritized multiple-assay biodosimetric-based strategy, concluding that no single assay is sufficiently robust to address all of the potential radiation

  10. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  11. Fifth personnel dosimetry intercomparison study

    Energy Technology Data Exchange (ETDEWEB)

    Sims, C.S.

    1980-02-01

    The fifth Personnel Dosimetry Intercomparison Study (PDIS) was conducted at the Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research (DOSAR) facility on March 20-22, 1979. This study is the latest PDIS in the continuing series started at the DOSAR facility in 1974. The PDIS is a three day study, typically in March, where personnel dosimeters are mailed to the DOSAR facility, exposed to a range of low-level neutron radiation doses (1 to 15 mSv or equivalently, 100 to 1500 mrem) and neutron-to-gamma ratios (1:1-10:1) using the Health Physics Research Reactor (HPRR) as the radiation source, and returned to the participants for evaluation. This report is a summary and analysis of the results reported by the various participants. The participants are able to intercompare their results with those of others who made dose measurements under identical experimental conditions.

  12. SU-E-J-215: Towards MR-Only Image Guided Identification of Calcifications and Brachytherapy Seeds: Application to Prostate and Breast LDR Implant Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Elzibak, A; Fatemi-Ardekani, A; Soliman, A; Mashouf, S; Safigholi, H; Ravi, A; Morton, G; Song, WY [Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Han, D [Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); University of California, San Diego, La Jolla, CA (United States)

    2015-06-15

    Purpose: To identify and analyze the appearance of calcifications and brachytherapy seeds on magnitude and phase MRI images and to investigate whether they can be distinguished from each other on corrected phase images for application to prostate and breast low dose rate (LDR) implant dosimetry. Methods: An agar-based gel phantom containing two LDR brachytherapy seeds (Advantage Pd-103, IsoAid, 0.8mm diameter, 4.5mm length) and two spherical calcifications (large: 7mm diameter and small: 4mm diameter) was constructed and imaged on a 3T Philips MR scanner using a 16-channel head coil and a susceptibility weighted imaging (SWI) sequence (2mm slices, 320mm FOV, TR/ TE= 26.5/5.3ms, 15 degree flip angle). The phase images were unwrapped and corrected using a 32×32, 2D Hanning high pass filter to remove background phase noise. Appearance of the seeds and calcifications was assessed visually and quantitatively using Osirix (http://www.osirix-viewer.com/). Results: As expected, calcifications and brachytherapy seeds appeared dark (hypointense) relative to the surrounding gel on the magnitude MRI images. The diameter of each seed without the surrounding artifact was measured to be 0.1 cm on the magnitude image, while diameters of 0.79 and 0.37 cm were measured for the larger and smaller calcifications, respectively. On the corrected phase images, the brachytherapy seeds and the calcifications appeared bright (hyperintense). The diameter of the seeds was larger on the phase images (0.17 cm) likely due to the dipole effect. Conclusion: MRI has the best soft tissue contrast for accurate organ delineation leading to most accurate implant dosimetry. This work demonstrated that phase images can potentially be useful in identifying brachytherapy seeds and calcifications in the prostate and breast due to their bright appearance, which helps in their visualization and quantification for accurate dosimetry using MR-only. Future work includes optimizing phase filters to best identify

  13. Real-time optical-fibre luminescence dosimetry for radiotherapy: physical characteristics and applications in photon beams

    DEFF Research Database (Denmark)

    Aznar, M.C.; Andersen, C.E.; Bøtter-Jensen, L.

    2004-01-01

    A new optical-fibre radiation dosimeter system, based on radioluminescence and optically stimulated luminescence from carbon-doped aluminium oxide, was developed and tested in clinical photon beams. This prototype offers several features, such as a small detector (1 x 1 x 2 mm), high sensitivity......, real-time read-out and the ability to measure both dose rate and absorbed dose. The measurements describing reproducibility and output dependence on dose rate, field size and energy all had standard deviations smaller than 1%. The signal variation with the angle of incidence was smaller than 2% (1 SD......). Measurements performed in clinical situations suggest the potential of using this real-time system for in vivo dosimetry in radiotherapy....

  14. [The application of ultrasonography to estimate blood vessel injury of upper limbs sustaining electric burns].

    Science.gov (United States)

    Chai, Jia-ke; Li, Li-gen; Chen, Yue-xiu; Hu, Xiao-juan; Yang, Yong-ming

    2003-12-01

    To explore a new method in estimating extent and degree of arterial injury in upper limbs sustaining high tension electric burns. Eighteen patients (twenty-four upper limbs) with high tension electricity injury were admitted from December 1998 to September 2002, The damaged limbs consisted of four parts: wrist wound part, 5 cm, 10 cm, 15 cm parts around wrist wound, where the radial and ulnar arteries were detected using B ultrasound and color WP Doppler examination. The changes of endangium, vessel diameter, thickness of the vessel wall and volume of blood flow were recorded respectively. The parameters of normal radial and ulnar arteries were also determined as normal control. B ultrasound and color WP Doppler examination showed that the endangium in radial and ulnar arteries become coarse, edema or exfoliation. The vessel wall was thicker than that of the normal control and the thickness was heterogeneity. The vessel wall could be necrosis in severe patient and the vessel cavity was stricture or beaded. Thrombosis or occlusion could occur at the site of severe injury area in vessel. The decrease in volume of blood flow was observed. The condition of the radial and ulnar arteries become well apart from 10 - 15 cm of wrist wound. The ultrasonography can be used to detect the changes in endangium, diameter, thickness of the vessel wall, blood flow volume in injury blood vessel caused by electric burn injury. It is helpful in judging the degree and extent of injury vessel and could be a safe, non-invasive diagnostic method and is worth popularizing.

  15. Practical Application Limits of Fuel Cells and Batteries for Zero Emission Vessels

    Energy Technology Data Exchange (ETDEWEB)

    Minnehan, John J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Energy Innovation Dept.; Pratt, Joseph William [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Energy Innovation Dept.

    2017-11-01

    Batteries and hydrogen fuel cells provide zero emission power at the point of use. They are studied as an alternative powerplant for maritime vessels by considering 14 case studies of various ship sizes and routes varying from small passenger vessels to the largest cargo ships. The method used was to compare the mass and volume of the required zero emission solution to the available mass and volume on an existing vessel considering its current engine and fuel storage systems. The results show that it is practically feasible to consider these zero emission technologies for most vessels in the world's fleet. Hydrogen fuel cells proved to be the most capable while battery systems showed an advantage for high power, short duration missions. The results provide a guide to ship designers to determine the most suitable types of zero emission powerplants to fit a ship based on its size and energy requirements.

  16. 46 CFR 117.10 - Applicability to vessels on an international voyage.

    Science.gov (United States)

    2010-10-01

    ... international voyage. A vessel on an international voyage subject to the International Convention for Safety of Life at Sea, 1974, as amended, (SOLAS) must meet the requirements in subchapter W of this chapter for...

  17. Synthesis of calcium carbonate nanocrystals and their potential application as vessels for drug delivery

    Science.gov (United States)

    Vergaro, Viviana; Carata, Elisabetta; Panzarini, Elisa; Baldassare, Francesca; Dini, Luciana; Ciccarella, Giuseppe

    2015-06-01

    Pure and stable calcium carbonate (CaCO3) nanocrystals were synthesized by spray drying method. We exploited the opportunity to use them as vessels for drug delivery studying the biocompatibility and the internalization in HeLa cells.

  18. Streamlined vessels for speedboats: Macro modifications of shark skin design applications

    Science.gov (United States)

    Ibrahim, M. D.; Amran, S. N. A.; Zulkharnain, A.; Sunami, Y.

    2018-01-01

    Functional properties of shark denticles have caught the attention of engineers and scientist today due to the hydrodynamic effects of its skin surface roughness. The skin of a fast swimming shark reveals riblet structures that help to reduce skin friction drag, shear stresses, making its movement to be more efficient and faster. Inspired by the structure of the shark skin denticles, our team has conducted a study on alternative on improving the hydrodynamic design of marine vessels by applying the simplified version of shark skin skin denticles on the surface hull of the vessels. Models used for this study are constructed and computational fluid dynamic (CFD) simulations are then carried out to predict the effectiveness of the hydrodynamic effects of the biomimetic shark skins on those models. Interestingly, the numerical calculated results obtained shows that the presence of biomimetic shark skin implemented on the vessels give improvements in the maximum speed as well as reducing the drag force experience by the vessels. The pattern of the wave generated post cruising area behind the vessels can also be observed to reduce the wakes and eddies. Theoretically, reduction of drag force provides a more efficient vessel with a better cruising speed. To further improve on this study, the authors are now actively arranging an experimental procedure in order to verify the numerical results obtained by CFD. The experimental test will be carried out using an 8 metre flow channel provided by University Malaysia Sarawak, Malaysia.

  19. Theoretical modelling of physiologically stretched vessel in magnetisable stent assisted magnetic drug targeting application

    Energy Technology Data Exchange (ETDEWEB)

    Mardinoglu, Adil [Telecommunications Software and Systems Group (TSSG), Waterford Institute of Technology, Waterford (Ireland); Cregg, P.J.; Murphy, Kieran [Materials Characterisation and Processing Group, SEAM Centre, Waterford Institute of Technology, Waterford (Ireland); Curtin, Maurice [Trinity Centre for Bioengineering, Trinity College, Dublin 2 (Ireland); Prina-Mello, Adriele, E-mail: prinamea@tcd.i [Trinity Centre for Bioengineering, Trinity College, Dublin 2 (Ireland); Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College, Dublin 2 (Ireland)

    2011-02-15

    The magnetisable stent assisted magnetic targeted drug delivery system in a physiologically stretched vessel is considered theoretically. The changes in the mechanical behaviour of the vessel are analysed under the influence of mechanical forces generated by blood pressure. In this 2D mathematical model a ferromagnetic, coiled wire stent is implanted to aid collection of magnetic drug carrier particles in an elastic tube, which has similar mechanical properties to the blood vessel. A cyclic mechanical force is applied to the elastic tube to mimic the mechanical stress and strain of both the stent and vessel while in the body due to pulsatile blood circulation. The magnetic dipole-dipole and hydrodynamic interactions for multiple particles are included and agglomeration of particles is also modelled. The resulting collection efficiency of the mathematical model shows that the system performance can decrease by as much as 10% due to the effects of the pulsatile blood circulation. - Research highlights: Theoretical modelling of magnetic drug targeting on a physiologically stretched stent-vessel system. Cyclic mechanical force applied to mimic the mechanical stress and strain of both stent and vessel. The magnetic dipole-dipole and hydrodynamic interactions for multiple particles is modelled. Collection efficiency of the mathematical model is calculated for different physiological blood flow and magnetic field strength.

  20. I-124 Imaging and Dosimetry

    Directory of Open Access Journals (Sweden)

    Russ Kuker

    2017-02-01

    Full Text Available Although radioactive iodine imaging and therapy are one of the earliest applications of theranostics, there still remain a number of unresolved clinical questions as to the optimization of diagnostic techniques and dosimetry protocols. I-124 as a positron emission tomography (PET radiotracer has the potential to improve the current clinical practice in the diagnosis and treatment of differentiated thyroid cancer. The higher sensitivity and spatial resolution of PET/computed tomography (CT compared to standard gamma scintigraphy can aid in the detection of recurrent or metastatic disease and provide more accurate measurements of metabolic tumor volumes. However the complex decay schema of I-124 poses challenges to quantitative PET imaging. More prospective studies are needed to define optimal dosimetry protocols and to improve patient-specific treatment planning strategies, taking into account not only the absorbed dose to tumors but also methods to avoid toxicity to normal organs. A historical perspective of I-124 imaging and dosimetry as well as future concepts are discussed.

  1. Small fields: nonequilibrium radiation dosimetry.

    Science.gov (United States)

    Das, Indra J; Ding, George X; Ahnesjö, Anders

    2008-01-01

    Advances in radiation treatment with beamlet-based intensity modulation, image-guided radiation therapy, and stereotactic radiosurgery (including specialized equipments like CyberKnife, Gamma Knife, tomotherapy, and high-resolution multileaf collimating systems) have resulted in the use of reduced treatment fields to a subcentimeter scale. Compared to the traditional radiotherapy with fields > or =4 x 4 cm2, this can result in significant uncertainty in the accuracy of clinical dosimetry. The dosimetry of small fields is challenging due to nonequilibrium conditions created as a consequence of the secondary electron track lengths and the source size projected through the collimating system that are comparable to the treatment field size. It is further complicated by the prolonged electron tracks in the presence of low-density inhomogeneities. Also, radiation detectors introduced into such fields usually perturb the level of disequilibrium. Hence, the dosimetric accuracy previously achieved for standard radiotherapy applications is at risk for both absolute and relative dose determination. This article summarizes the present knowledge and gives an insight into the future procedures to handle the nonequilibrium radiation dosimetry problems. It is anticipated that new miniature detectors with controlled perturbations and corrections will be available to meet the demand for accurate measurements. It is also expected that the Monte Carlo techniques will increasingly be used in assessing the accuracy, verification, and calculation of dose, and will aid perturbation calculations of detectors used in small and highly conformal radiation beams. rican Association of Physicists in Medicine.

  2. Hybrid Computational Phantoms Representing the Reference Adult Male and Adult Female: Construction and Applications for Retrospective Dosimetry

    Science.gov (United States)

    Hurtado, Jorge L.; Lee, Choonsik; Lodwick, Daniel; Goede, Timothy; Williams, Jonathan L.; Bolch, Wesley E.

    2013-01-01

    Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Mathematical surface equations in stylized phantoms are flexible but the resulting anatomy is not as realistic. Voxel phantoms display far better anatomical realism, but they are limited in terms of their ability to alter organ shape, position, and depth, as well as body posture. A new class of computational phantoms - called hybrid phantoms - takes advantage of the best features of stylized and voxel phantoms - flexibility and anatomical realism, respectively. In the current study, hybrid computational phantoms representing the adult male and female reference anatomy and anthropometry are presented. These phantoms serve as the starting framework for creating patient or worker sculpted whole-body phantoms for retrospective dose reconstruction. Contours of major organs and tissues were converted or segmented from computed tomography images of a 36-year Korean volunteer and a 25-year U.S. female patient, respectively, with supplemental high-resolution CT images for the cranium. Polygon mesh models for the major organs and tissues were reconstructed and imported into Rhinoceros™ for non-uniform rational B-spline (NURBS) surface modeling. The resulting NURBS/polygon mesh models representing body contour and internal anatomy were matched to anthropometric data and reference organ mass data provided by Centers for Disease Control and Prevention (CDC) and International Commission on Radiation Protection (ICRP), respectively. Finally, two hybrid adult male and female phantoms were completed where a total of 8 anthropometric data categories were matched to standard values within 4% and organ volumes matched to ICRP data within 1% with the exception of total skin. The hybrid phantoms were voxelized from

  3. MO-B-BRB-00: Three Dimensional Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  4. MICROVEGA (MICRO VESSEL FOR GEODETICS APPLICATION: A MARINE DRONE FOR THE ACQUISITION OF BATHYMETRIC DATA FOR GIS APPLICATIONS

    Directory of Open Access Journals (Sweden)

    F. Giordano

    2015-04-01

    Full Text Available Bathymetric data are fundamental to produce navigational chart and sea-floor 3D models. They can be collected using different techniques and sensors on board of a variety of platforms, such as satellite, aircraft, ship and drone. The MicroVEGA drone is an Open Prototype of Autonomous Unmanned Surface Vessel (AUSV conceived, designed and built to operate in the coastal areas (0-20 meters of depth, where a traditional boat is poorly manoeuvrable. It is equipped with a series of sensors to acquire the morpho-bathymetric high precision data. In this paper we presents the result of the first case study, a bathymetric survey carried out at Sorrento Marina Grande. This survey is a typical application case of this technology; the Open Prototype MicroVega has an interdisciplinary breath and it is going to be applied to various research fields. In future, it will expect to do new knowledge, new survey strategies and an industrial prototype in fiberglass.

  5. Application of high strength MnMoNi steel to pressure vessels for nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K.; Kurihara, I.; Sasaki, T.; Koyama, Y.; Tanaka, Y. [The Japan Steel Works, Ltd. (Japan)

    1999-07-01

    Recent increase in output of nuclear power plant has been attained by enlargement of major components such as pressure vessels. Such large components have almost reached limit of size from the points of manufacturing capacity and cost in both forgemasters and fabricaters. In order to solve this problem, it must be beneficial to apply design by use of material of higher strength which brings reduction of pressure vessel thickness and weight. The Japan Steel Works, Ltd. (JSW) has many manufacturing experiences of large integrated forgings made from high strength MnMoNi steel with tensile strength level of 620MPa for steam generator (SG) pressure vessel, and has made confirmation tests of its material properties. This paper describes the confirmation test results such as tensile and impact properties, nil-ductility transition temperature (NDT-T), static and dynamic fracture toughness weldability including under clad cracking (UCC) sensitivity and metallurgical factors which influence on such material properties. (orig.)

  6. Application of high strength MnMoNi steel to pressure vessels for nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K. E-mail: koumei_suzuki@jsw.co.jp; Kurihara, I.; Sasaki, T.; Koyoma, Y.; Tanaka, Y

    2001-06-01

    Recent increase in output of nuclear power plant has been attained by enlargement of major components such as pressure vessels. Such large components have almost reached a size limit from the points of manufacturing capacity and cost in both forgemasters and fabricaters. In order to solve this problem, it must be beneficial to apply design by use of material of higher strength, which brings reduction of pressure vessel thickness and weight. The Japan Steel Works Ltd. (JSW) has many manufacturing experiences of large integrated forgings made from high strength MnMoNi steel with tensile strength level of 620 MPa for steam generator (SG) pressure vessel, and has performed confirmation tests of its material properties. This paper describes the confirmation test results such as tensile and impact properties, nil-ductility transition temperature (NDT-T), static and dynamic fracture toughness, weldability including under-clad cracking (UCC) sensitivity, as well as metallurgical factors which influence on such material properties.

  7. Active Contours Driven by Multi-Feature Gaussian Distribution Fitting Energy with Application to Vessel Segmentation.

    Science.gov (United States)

    Wang, Lei; Zhang, Huimao; He, Kan; Chang, Yan; Yang, Xiaodong

    2015-01-01

    Active contour models are of great importance for image segmentation and can extract smooth and closed boundary contours of the desired objects with promising results. However, they cannot work well in the presence of intensity inhomogeneity. Hence, a novel region-based active contour model is proposed by taking image intensities and 'vesselness values' from local phase-based vesselness enhancement into account simultaneously to define a novel multi-feature Gaussian distribution fitting energy in this paper. This energy is then incorporated into a level set formulation with a regularization term for accurate segmentations. Experimental results based on publicly available STructured Analysis of the Retina (STARE) demonstrate our model is more accurate than some existing typical methods and can successfully segment most small vessels with varying width.

  8. Individual dosimetry of workers and patients: implementation and perspectives; La dosimetrie individuelle des travailleurs et de patients: mise en oeuvre et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E

    2008-07-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  9. Probabilistic Analysis of Collision Damages with Application to ro-Ro Passenger Vessels

    DEFF Research Database (Denmark)

    Pedersen, Preben Terndrup; Hansen, Peter Friis; Nielsen, Lars Peter

    1997-01-01

    To quantify the risks involved in Ro-ro passenger vessel traffic, rational criteria for prediction and evaluation of collision accidents have to be developed. This implies that probabilities as well as the inherent consequences have to be analyzed and assessed.The present report outlines a method...... for evaluation of the probability of a Ro-Ro passenger vessel on a given route being struck by another ship. Given a collision has taken place the spatial distribution of the collision damages is calculated. Results are presented in terms of probability distributions, for indentation depth, length and height...

  10. New angiographic measurement tool for analysis of small cerebral vessels: application to a subarachnoid haemorrhage model in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Turowski, B.; Moedder, U. [Heinrich-Heine University, Institute of Diagnostic Radiology, Neuroradiology, Duesselorf (Germany); Haenggi, D.; Steiger, H.J. [Heinrich-Heine University, Department of Neurosurgery, Duesseldorf (Germany); Beck, A.; Aurich, V. [Heinrich-Heine University, Institute of Informatics, Duesseldorf (Germany)

    2007-02-15

    Exact quantification of vasospasm by angiography is known to be difficult especially in small vessels. The purpose of the study was to develop a new method for computerized analysis of small arteries and to demonstrate feasibility on cerebral angiographies of rats acquired on a clinical angiography unit. A new software tool analysing grey values and subtracting background noise was validated on a vessel model. It was tested in practice in animals with subarachnoid haemorrhage (SAH). A total of 28 rats were divided into four groups: SAH untreated, SAH treated with local calcium antagonist, SAH treated with placebo, and sham-operated. The diameters of segments of the internal carotid, caudal cerebral, middle cerebral, rostral cerebral and the stapedial arteries were measured and compared to direct measurements of the diameters on magnified images. There was a direct correlation between the cross-sectional area of vessels measured in a phantom and the measurements acquired using the new image analysis method. The spread of repeated measurements with the new software was small compared to the spread of direct measurements of vessel diameters on magnified images. Application of the measurement tool to experimental SAH in rats showed a statistically significant reduction of vasospasm in the SAH groups treated with nimodipine-releasing pellets in comparison to all the other groups combined. The presented computerized method for analysis of small intracranial vessels is a new method allowing precise relative measurements. Nimodipine-releasing subarachnoidal pellets reduce vasospasm, but further testing with larger numbers is necessary. The tool can be applied to human angiography without modification and offers the promise of substantial progress in the diagnosis of vasospasm after SAH. (orig.)

  11. Application of computational fluid dynamics to regional dosimetry of inhaled chemicals in the upper respiratory tract of the rat.

    Science.gov (United States)

    Kimbell, J S; Gross, E A; Joyner, D R; Godo, M N; Morgan, K T

    1993-08-01

    For certain inhaled air pollutants, such as reactive, water soluble gases, the distribution of nasal lesions observed in F344 rats may be closely related to regional gas uptake patterns in the nose. These uptake patterns can be influenced by the currents of air flowing through the upper respiratory tract during the breathing cycle. Since data on respiratory tract lesions in F344 rats are extrapolated to humans to make predictions of risk to human health, a better understanding of the factors affecting these responses is needed. To assess potential effects of nasal airflow on lesion location and severity, a methodology was developed for creation of computer simulations of steady-state airflow and gas transport using a three-dimensional finite element grid reconstructed from serial step-sections of the nasal passages of a male F344 rat. Simulations on a supercomputer used the computational fluid dynamics package FIDAP (FDI, Evanston, IL). Distinct streams of bulk flow evident in the simulations matched inspiratory streams reported for the F344 rat. Moreover, simulated regional flow velocities matched measured velocities in concurrent laboratory experiments with a hollow nasal mold. Computer-predicted flows were used in simulations of gas transport to nasal passage walls, with formaldehyde as a test case. Results from the uptake simulations were compared with the reported distribution of formaldehyde-induced nasal lesions observed in the F344 rat, and indicated that airflow-driven uptake patterns probably play an important role in determining the location of certain nasal lesions induced by formaldehyde. This work demonstrated the feasibility of applying computational fluid dynamics to airflow-driven dosimetry of inhaled chemicals in the upper respiratory tract.

  12. A new surrogate modeling technique combining Kriging and polynomial chaos expansions – Application to uncertainty analysis in computational dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kersaudy, Pierric, E-mail: pierric.kersaudy@orange.com [Orange Labs, 38 avenue du Général Leclerc, 92130 Issy-les-Moulineaux (France); Whist Lab, 38 avenue du Général Leclerc, 92130 Issy-les-Moulineaux (France); ESYCOM, Université Paris-Est Marne-la-Vallée, 5 boulevard Descartes, 77700 Marne-la-Vallée (France); Sudret, Bruno [ETH Zürich, Chair of Risk, Safety and Uncertainty Quantification, Stefano-Franscini-Platz 5, 8093 Zürich (Switzerland); Varsier, Nadège [Orange Labs, 38 avenue du Général Leclerc, 92130 Issy-les-Moulineaux (France); Whist Lab, 38 avenue du Général Leclerc, 92130 Issy-les-Moulineaux (France); Picon, Odile [ESYCOM, Université Paris-Est Marne-la-Vallée, 5 boulevard Descartes, 77700 Marne-la-Vallée (France); Wiart, Joe [Orange Labs, 38 avenue du Général Leclerc, 92130 Issy-les-Moulineaux (France); Whist Lab, 38 avenue du Général Leclerc, 92130 Issy-les-Moulineaux (France)

    2015-04-01

    In numerical dosimetry, the recent advances in high performance computing led to a strong reduction of the required computational time to assess the specific absorption rate (SAR) characterizing the human exposure to electromagnetic waves. However, this procedure remains time-consuming and a single simulation can request several hours. As a consequence, the influence of uncertain input parameters on the SAR cannot be analyzed using crude Monte Carlo simulation. The solution presented here to perform such an analysis is surrogate modeling. This paper proposes a novel approach to build such a surrogate model from a design of experiments. Considering a sparse representation of the polynomial chaos expansions using least-angle regression as a selection algorithm to retain the most influential polynomials, this paper proposes to use the selected polynomials as regression functions for the universal Kriging model. The leave-one-out cross validation is used to select the optimal number of polynomials in the deterministic part of the Kriging model. The proposed approach, called LARS-Kriging-PC modeling, is applied to three benchmark examples and then to a full-scale metamodeling problem involving the exposure of a numerical fetus model to a femtocell device. The performances of the LARS-Kriging-PC are compared to an ordinary Kriging model and to a classical sparse polynomial chaos expansion. The LARS-Kriging-PC appears to have better performances than the two other approaches. A significant accuracy improvement is observed compared to the ordinary Kriging or to the sparse polynomial chaos depending on the studied case. This approach seems to be an optimal solution between the two other classical approaches. A global sensitivity analysis is finally performed on the LARS-Kriging-PC model of the fetus exposure problem.

  13. Trainable COSFIRE filters for vessel delineation with application to retinal images

    NARCIS (Netherlands)

    Azzopardi, G; Strisciuglio, N.; Vento, M.; Petkov, N.

    2015-01-01

    Retinal imaging provides a non-invasive opportunity for the diagnosis of several medical pathologies. The automatic segmentation of the vessel tree is an important pre-processing step which facilitates subsequent automatic processes that contribute to such diagnosis. We introduce a novel method for

  14. Dosimetry of ionising radiation in modern radiation oncology

    Science.gov (United States)

    Kron, Tomas; Lehmann, Joerg; Greer, Peter B.

    2016-07-01

    Dosimetry of ionising radiation is a well-established and mature branch of physical sciences with many applications in medicine and biology. In particular radiotherapy relies on dosimetry for optimisation of cancer treatment and avoidance of severe toxicity for patients. Several novel developments in radiotherapy have introduced new challenges for dosimetry with small and dynamically changing radiation fields being central to many of these applications such as stereotactic ablative body radiotherapy and intensity modulated radiation therapy. There is also an increasing awareness of low doses given to structures not in the target region and the associated risk of secondary cancer induction. Here accurate dosimetry is important not only for treatment optimisation but also for the generation of data that can inform radiation protection approaches in the future. The article introduces some of the challenges and highlights the interdependence of dosimetric calculations and measurements. Dosimetric concepts are explored in the context of six application fields: reference dosimetry, small fields, low dose out of field, in vivo dosimetry, brachytherapy and auditing of radiotherapy practice. Recent developments of dosimeters that can be used for these purposes are discussed using spatial resolution and number of dimensions for measurement as sorting criteria. While dosimetry is ever evolving to address the needs of advancing applications of radiation in medicine two fundamental issues remain: the accuracy of the measurement from a scientific perspective and the importance to link the measurement to a clinically relevant question. This review aims to provide an update on both of these.

  15. Application of voxelised phantoms to the dosimetry simulation of radiation accidents; Application des fantomes voxelises pour la reconstitution dosimetrique d'accident radiologique

    Energy Technology Data Exchange (ETDEWEB)

    Lemosquet, A.; Clairand, I.; Carlan, L. de; Aubineau-Laniece, I.; Rioual, J.B.; Bottollier-Depois, J.F.; Franck, D. [Institut de Radioprotection et de Surete Nucleaire Departement de Protection de la sante de l' Homme et de Dosimetrie Service de Dosimetrie, 92 - Fontenay-aux-Roses (France)

    2003-07-01

    In the case of a radiation accident it is possible to estimate the radiation dose received by the victim by techniques of physical processing by calculation, especially to determine the heterogeneity of the distribution dose in depth. The work bears on the development of a new computer tool devoted to the dosimetry reconstitution of a radiation accident coming from an external source that has the particularity to associate a voxelised anthropomorph geometry to a Monte Carlo code. The functionalities of the tool are described. (N.C.)

  16. Commissioning of applicator-guided stereotactic body radiation therapy boost with high-dose-rate brachytherapy for advanced cervical cancer using radiochromic film dosimetry.

    Science.gov (United States)

    Aldelaijan, Saad; Wadi-Ramahi, Shada; Nobah, Ahmad; Moftah, Belal; Devic, Slobodan; Jastaniyah, Noha

    To describe an EBT3 GAFCHROMIC film-based dosimetry method to be used in commissioning of a combined HDR brachytherapy (HDRB) and stereotactic body radiation therapy (SBRT) boost for treatment of advanced cervical cancer involving extensive residual disease after external beam treatment. A cube phantom was designed to firmly fit an intrauterine tandem applicator and EBT3 radiochromic film pieces. A high-risk clinical target volume (CTVHR, Total) was contoured with an extended arm at one side. The HDRB treatment was planned to cover the proximal CTVHR, Total with 7 Gy and the distal volume, referred to as CTVHR, Distal, was planned by SBRT for dose augmentation. After HDRB treatment delivery, SBRT treatment was delivered within 1 hour by image guidance using the applicator geometry. Intentional 1D and 2D misalignments were introduced to evaluate the effect on target volumes. In addition, effect of film reirradiation at different time gaps and dose levels was evaluated. Film dosimetric accuracy, with up to 2 hours gap between irradiations, was shown to be unaffected. A 2%/2 mm gamma analysis between measured and planned doses showed agreement of >99%. Misalignments of more than 2 mm between applicator and SBRT isocenter resulted in suboptimal dose-volume histogram affecting mostly D98% and D90% of CTVHR, Distal. Visualizing how target dose-volume metrics are affected by minor misalignments between SBRT and HDRB dose gradients, in light of achievable phantom-based experimental quality assurance level, encourages the clinical applicability of this technique. Radiochromic film was shown to be a valuable tool to commission procedures combining two different treatment planning systems and modalities with varying dose rates and energy ranges. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Thermoluminescence dosimetry of rare earth doped calcium ...

    Indian Academy of Sciences (India)

    Unknown

    CaAl2O4) doped with different rare earth ions have been studied and their suitability for radiation dosimetry applications is discussed. It is observed that monocalcium aluminate doped with cerium is a good dosimeter having linear response up to ...

  18. Thermoluminescence dosimetry of rare earth doped calcium ...

    Indian Academy of Sciences (India)

    The thermoluminescence (TL) properties of calcium aluminate (CaAl2O4) doped with different rare earth ions have been studied and their suitability for radiation dosimetry applications is discussed. It is observed that monocalcium aluminate doped with cerium is a good dosimeter having linear response up to about 4 kGy of ...

  19. The Pelletron Accelerator of IFUNAM and its possible applications to the dosimetry; El Acelerador Pelletron del IFUNAM y sus posibles aplicaciones a la dosimetria

    Energy Technology Data Exchange (ETDEWEB)

    Rickards, J. [Instituto de Fisica, UNAM, Circuito Exterior, C.U. 04510 Mexico D.F. (Mexico)

    1999-07-01

    The Pelletron Accelerator of positive ions 3 MV in the Institute of Physics of UNAM has characteristics that make it useful for the application to the radiations dosimetry. It is ideal for studying the detailed mechanisms of the radiation interaction with matter, therefore it can be applied to know the performance of dosemeters. With this device can be accelerated almost any type of ion, including He, but excepting the others noble gases. The energies of the disposable ions are in the interval 1 MeV until several MeV, depending of the state of charge selected, the energy can be varied continuously with accuracy of some KeV. It can be achieved streams from 10{sup 4} until 10{sup 6} ions/cm{sup 2}, allowing studies of individual events (tracks) or of collective processes. the beam size can be varying from a diameter 1 mm until 5 cm. It is also took in account with detectors and other techniques associated that can be combined for supporting studies, as surface barrier detectors and of other types, as well as the RBS, PIXE, RN techniques and channeling. (Author)

  20. Application of the Electron paramagnetic resonance to the ionizing radiation dosimetry; Aplicacion de la Resonancia paramagnetica electronica a la dosimetria de las radiaciones ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Urena N, F. [Instituto Nacional de Investigaciones Nucleares, Km. 36.5 Carretera Mexico-Toluca, 52045 Salazar, Estado de Mexico (Mexico)

    2000-07-01

    The Electron Paramagnetic Resonance (EPR) is defined as the resonant absorption of electromagnetic energy in paramagnetic substances by the spin transition of a non-pairing electron between different energy levels in presence of a magnetic field. (Slighter, 1989). One of the more important characteristic of EPR is that the electron spin levels are subdivided by the electron interaction with the magnetic dipoles of the nearby nucleus giving occasion for a spectral structure called hyperfine structure. In this kind of interactions two limit cases are distinguished: 1. when the non-pairing electron is located in a central ion surrounded of atoms belonging to coordinate molecules. 2. When a non-pairing electron interactioning in the same form with a number of equivalent nucleus, which is common in organic radicals, these will give as result spectra. Some EPR spectrometer can be used to dosimetric purposes by free radicals via. In this work, it is presented the application of EPR to dosimetry of ionizing radiations by free radicals via which allows to determinations of high doses. (Author)

  1. Application of the correction factor for radiation qualityK{sub q} in dosimetry with pencil-type ionization chambers using a Tandem system

    Energy Technology Data Exchange (ETDEWEB)

    Fontes, Ladyjane Pereira; Potiens, Maria da Penha Albuquerque, E-mail: lpfontes@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    The pencil-type ionization chamber widely used in computed tomography (CT) dosimetry, is a measuring instrument that has a cylindrical shape and provides uniform response independent of the angle of incidence of ionizing radiation. Calibration and measurements performed with the pencil-type ionization chamber are done in terms of Kerma product in air-length (P{sub k,l}) and values are given in Gy.cm. To obtain the values of (P{sub k,l}) during clinical measurements, the readings performed with the ionization chamber are multiplied by the calibration coefficient (N{sub k,l}) and the correction factor C for quality (K{sub q}) which are given in Calibration certificates of the chambers. The application of the correction factor for radiation quality K{sub q} is done as a function of the effective energy of the beam that is determined by the Half Value layer (HVL) calculation. In order to estimate the HVL values in this work, a Tandem system made up of cylindrical aluminum and PMMA absorber layers was used as a low cost and easy to apply method. From the Tandem curve, it was possible to construct the calibration curve and obtain the appropriate K{sub q} to the beam of the computed tomography equipment studied. (author)

  2. Update of computer applications associated to measuring equipment of the services of internal dosimetry of NPPS and Tecnatom; Actualizacion de las aplicaciones informaticas asociadas a los equipos de medida de los Servicios de Dosimetria Interna de las CCNN y de Tecnatom

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, B.; Sollet, E.; Serrano, E.

    2014-07-01

    Within the continuous improvement processes that take place in all the activities taking place in the Spanish nuclear power plants, and as a result of implementation of ISO Standards for Internal Dosimetry, has undertaken a review, improvement and updating INDAC ALEDIN and applications associated with measuring equipment and DIYs Quicky kind Personal Internal Dosimetry Services of the Spanish nuclear power plants and Tecnatom This paper presents updates capacities both tools. (Author)

  3. Application of ion beam irradiated ePTFE to repair small vessel injuries

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, N. [Tokyo University of Science, 1-3 Kagurazaka, Shinjuku, Tokyo 162-8601 (Japan) and Beam Application Team, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)]. E-mail: norikichi@ionbeams.riken.jp; Suzuki, Y. [Beam Application Team, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Ujiie, H. [Tokyo Women' s Medical University, 8-1 Kawada-cho, Shinjuku, Tokyo 162-8666 (Japan); Hori, T. [Tokyo Women' s Medical University, 8-1 Kawada-cho, Shinjuku, Tokyo 162-8666 (Japan); Iwaki, M. [Beam Application Team, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Yamada, T. [Tokyo University of Science, 1-3 Kagurazaka, Shinjuku, Tokyo 162-8601 (Japan)

    2007-04-15

    In surgery, bleeding from small injured vessels often requires prompt hemostasis without occlusion. This study evaluated the usefulness of 0.06 mm thick ion beam irradiated ePTFE sheets to repair small holes in vessels. Both surfaces of ePTFE sheets were irradiated with a 150 keV-Ar{sup +} beam with fluences of 5 x 10{sup 14} ions/cm{sup 2}. A small hole up to 2 mm in diameter was created in the common carotid artery of a rabbit. The defect was wrapped with an ion beam irradiated or non-irradiated ePTFE sheet. Fibrin glue was used to fix the ePTFE sheets to the common carotid artery. Hemostasis was instantly obtained with ion beam irradiated ePTFE but was rather difficult when using a non-irradiated ePTFE sheet. Three weeks after implantation, no occlusion was observed. Histological examination showed that the ePTFE sheets functioned as a scaffold for vessel wall regeneration. Thin ion beam irradiated ePTFE would be useful in vascular surgery.

  4. Characterization dosimetry of applicators Valencia using different techniques; Caracterizacion dosimetrica de los aplicadores Valencia mediante diferentes tecnicas

    Energy Technology Data Exchange (ETDEWEB)

    Ferrer Garcia, C.; Huertas, C.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-07-01

    Valencia applicators, connected to a charging system deferred micro Selectron-HDR (Elekta-Nucletron), are used for treating small skin lesions, being an alternative to treatments with electron beams or orthovoltage equipment of X ray. These applicators are a modification of Leipzig applicators, consisting of a flatter filter, which flattens the dose distribution in the area of treatment [1,2]. In the present study are considered applicators with diameters of 2 and 3 cm (VH2 and ht5), with the parallel to the treatment area source. Due to the electronic pollution on the walls of the applicator, treatments are performed with a plastic cap. In this study are commissions Valencia applicators, checking the various options proposed in the literature. (Author)

  5. Nuclear medicine radiation dosimetry

    CERN Document Server

    McParland, Brian J

    2010-01-01

    Complexities of the requirements for accurate radiation dosimetry evaluation in both diagnostic and therapeutic nuclear medicine (including PET) have grown over the past decade. This is due primarily to four factors: growing consideration of accurate patient-specific treatment planning for radionuclide therapy as a means of improving the therapeutic benefit, development of more realistic anthropomorphic phantoms and their use in estimating radiation transport and dosimetry in patients, design and use of advanced Monte Carlo algorithms in calculating the above-mentioned radiation transport and

  6. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  7. Medical reference dosimetry using EPR measurements of alanine

    DEFF Research Database (Denmark)

    Helt-Hansen, Jakob; Rosendal, F.; Kofoed, I.M.

    2009-01-01

    Background. Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low...... methods the proposed algorithm can be applied without normalisation of phase shifts caused by changes in the g-value of the cavity. The study shows that alanine dosimetry is a suitable candidate for medical reference dosimetry especially for quality control applications....

  8. Status of radiation processing dosimetry

    DEFF Research Database (Denmark)

    Miller, A.

    1993-01-01

    Several milestones have marked the field of radiation processing dosimetry since IMRP 7. Among them are the IAEA symposium on High Dose Dosimetry for Radiation Processing and the international Workshops on Dosimetry for Radiation Processing organized by the ASTM. Several standards have been...... or are being published by the ASTM in this field, both on dosimetry procedures and on the proper use of specific dosimeter systems. Several individuals are involved in this international cooperation which contribute significantly to the broader understanding of the role of dosimetry in radiation processing....... The importance of dosimetry is emphasized in the standards on radiation sterilization which are currently drafted by the European standards organization CEN and by the international standards organization ISO. In both standards, dosimetry plays key roles in characterization of the facility, in qualification...

  9. [Ultrasound and color Doppler applications in nephrology. The normal kidney: anatomy, vessels and congenital anomalies].

    Science.gov (United States)

    Meola, Mario; Petrucci, Ilaria; Giovannini, Lisa; Samoni, Sara; Dellafiore, Carolina

    2012-01-01

    Gray-scale ultrasound is the diagnostic technique of choice in patients with suspected or known renal disease. Knowledge of the normal and abnormal sonographic morphology of the kidney and urinary tract is essential for a successful diagnosis. Conventional sonography must always be complemented by Doppler sampling of the principal arterial and venous vessels. B-mode scanning is performed with the patient in supine, prone or side position. The kidney can be imaged by the anterior, lateral or posterior approach using coronal, transverse and oblique scanning planes. Morphological parameters that must be evaluated are the coronal diameter, the parenchymal thickness and echogenicity, the structure and state of the urinary tract, and the presence of congenital anomalies that may mimic a pseudomass. The main renal artery and the hilar-intraparenchymal branches of the arterial and venous vessels should be accurately evaluated using color Doppler. Measurement of intraparenchymal resistance indices (IP, IR) provides an indirect and quantitative parameter of the stiffness and eutrophic or dystrophic remodeling of the intrarenal microvasculature. These parameters differ depending on age, diabetic and hypertensive disease, chronic renal glomerular disease, and interstitial, vascular and obstructive nephropathy.

  10. SU-E-T-459: Impact of Source Position and Traveling Time On HDR Skin Surface Applicator Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J; Barker, C; Zaider, M; Cohen, G [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2015-06-15

    Purpose: Observed dosimetric discrepancy between measured and treatment planning system (TPS) predicted values, during applicator commissioning, were traced to source position uncertainty in the applicator. We quantify the dosimetric impact of this geometric uncertainty, and of the source traveling time inside the applicator, and propose corrections for clinical use. Methods: We measured the dose profiles from the Varian Leipzig-style (horizontal) HDR skin applicator, using EBT3 film, photon diode, and optically stimulated luminescence dosimeter (OSLD) and three different GammaMed HDR afterloders. The dose profiles and depth dose of each aperture were measured at several depths (up to about 10 mm, depending on the dosimeter). The measured dose profiles were compared with Acuros calculated profiles in BrachyVision TPS. For the impact of the source position, EBT3 film measurements were performed with applicator, facing-down and facing-up orientations. The dose with and without source traveling was measured with diode detector using HDR timer and electrometer timer, respectively. Results: Depth doses measured using the three dosimeters were in good agreement, but were consistently higher than the Acuros dose calculations. Measurements with the applicator facing-up were significantly lower than those in the facing-down position with maximum difference of about 18% at the surface, due to source sag inside the applicator. Based on the inverse-square law, the effective source sag was evaluated to be about 0.5 mm from the planned position. The additional dose from the source traveling was about 2.8% for 30 seconds with 10 Ci source, decreasing with increased dwelling time and decreased source activity. Conclusion: Due to the short source-to-surface distance of the applicator, the small source sag inside the applicator has significant dosimetric impact, which should be considered before the clinical use of the applicator. Investigation of the effect for other applicators

  11. INDIVIDUAL DOSIMETRY SERVICE

    CERN Multimedia

    2002-01-01

    Deadline...Deadline...Deadline...Deadline...Deadline...Deadline...   Individual dosimetry service We inform all staffs and users under regular dosimetric control that the dosimeters for the monitoring period JANUARY/FEBRUARY 2002 are available from their usual dispatchers. Please have your films changed before the 15th of January. The color of the dosimeter valid in JANUARY/FEBRUARY is WHITE.

  12. Dosimetry in diagnostic radiology.

    Science.gov (United States)

    Meghzifene, Ahmed; Dance, David R; McLean, Donald; Kramer, Hans-Michael

    2010-10-01

    Dosimetry is an area of increasing importance in diagnostic radiology. There is a realisation amongst health professionals that the radiation dose received by patients from modern X-ray examinations and procedures can be at a level of significance for the induction of cancer across a population, and in some unfortunate instances, in the acute damage to particular body organs such as skin and eyes. The formulation and measurement procedures for diagnostic radiology dosimetry have recently been standardised through an international code of practice which describes the methodologies necessary to address the diverging imaging modalities used in diagnostic radiology. Common to all dosimetry methodologies is the measurement of the air kerma from the X-ray device under defined conditions. To ensure the accuracy of the dosimetric determination, such measurements need to be made with appropriate instrumentation that has a calibration that is traceable to a standards laboratory. Dosimetric methods are used in radiology departments for a variety of purposes including the determination of patient dose levels to allow examinations to be optimized and to assist in decisions on the justification of examination choices. Patient dosimetry is important for special cases such as for X-ray examinations of children and pregnant patients. It is also a key component of the quality control of X-ray equipment and procedures. Copyright © 2010. Published by Elsevier Ireland Ltd.

  13. Ion-kill dosimetry

    Science.gov (United States)

    Katz, R.; Cucinotta, F. A.; Fromm, M.; Chambaudet, A.

    2001-01-01

    Unanticipated late effects in neutron and heavy ion therapy, not attributable to overdose, imply a qualitative difference between low and high LET therapy. We identify that difference as 'ion kill', associated with the spectrum of z/beta in the radiation field, whose measurement we label 'ion-kill dosimetry'.

  14. Advances in radiation therapy dosimetry

    Directory of Open Access Journals (Sweden)

    Paliwal Bhudatt

    2009-01-01

    Full Text Available During the last decade, there has been an explosion of new radiation therapy planning and delivery tools. We went through a rapid transition from conventional three-dimensional (3D conformal radiation therapy to intensity-modulated radiation therapy (IMRT treatments, and additional new techniques for motion-adaptive radiation therapy are being introduced. These advances push the frontiers in our effort to provide better patient care; and with the addition of IMRT, temporal dimensions are major challenges for the radiotherapy patient dosimetry and delivery verification. Advanced techniques are less tolerant to poor implementation than are standard techniques. Mis-administrations are more difficult to detect and can possibly lead to poor outcomes for some patients. Instead of presenting a manual on quality assurance for radiation therapy, this manuscript provides an overview of dosimetry verification tools and a focused discussion on breath holding, respiratory gating and the applications of four-dimensional computed tomography in motion management. Some of the major challenges in the above areas are discussed.

  15. Application of novel linear active disturbance rejection control in dynamic positioning control system of vessels

    Directory of Open Access Journals (Sweden)

    JIN Yue

    2017-01-01

    Full Text Available Aiming at the problem in which a vessel's dynamic positioning system can control it at an expected position,a novel linear active disturbance rejection controller is designed to solve the problem of poor dynamic performance due to the omission of a tracking differentiator. Based on the advantages of linear and nonlinear tracking differentiators,an improved tracking differentiator is designed which can track the differential signal and degrade the effects of noise; it constitutes a novel Linear Active Disturbance Rejection Controller(LADRC. The simulation results show that the novel LADRC based on the improved tracking differentiator has strong robustness,high control accuracy and good dynamic performance compared with the traditional LADRC.

  16. A fiber-dosimetry method based on OSL from Al2O3:C for radiotherapy applications

    DEFF Research Database (Denmark)

    Gaza, R.; McKeever, S.W.S.; Akselrod, M.S.

    2004-01-01

    We describe a high-sensitivity, fiber-optic dosimetry system based on optically stimulated luminescence (OSL) and radioluminescence from Al2O3: C single-crystal fibers (detectors). The detectors are coupled to a fiber optic delivery system and OSL from the detector is stimulated via the optical f...

  17. SU-F-T-08: Brachytherapy Film Dosimetry in a Water Phantom for a Ring and Tandem HDR Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B; Grelewicz, Z; Kang, Z; Cutright, D; Gopalakrishnan, M; Sathiaseelan, V; Zhang, H [Northwestern Memorial Hospital, Chicago, IL (United States)

    2016-06-15

    Purpose: The feasibility of dose measurement using new generation EBT3 film was explored in a water phantom for a ring and tandem HDR applicator for measurements tracking mucosal dose during cervical brachytherapy. Methods: An experimental fixture was assembled to position the applicator in a water phantom. Prior to measurement, calibration curves for EBT3 film in water and in solidwater were verified. EBT3 film was placed at different known locations around the applicator in the water tank. A CT scan of the phantom with applicator was performed using clinical protocol. A typical cervical cancer treatment plan was then generated by Oncentra brachytherapy planning system. A dose of 500 cGy was prescribed to point A (2 cm, 2 cm). Locations measured by film included the outer surface of the ring, measurement point A-m (2.2 cm, 2.2 cm), and profiles extending from point A-m parallel to the tandem. Three independent measurements were conducted. The doses recorded by film were carefully analyzed and compared with values calculated by the treatment planning system. Results: Assessment of the EBT3 films indicate that the dose at point A matches the values predicted by the planning system. Dose to the point A-m was 411.5 cGy, and the outer circumferential surface dose of the ring was between 500 and 1150 cGy. It was found that from the point A-m, the dose drops 60% within 4.5 cm on the line parallel to the tandem. The measurement doses agree with the treatment planning system. Conclusion: Use of EBT3 film is feasible for in-water measurements for brachytherapy. A carefully machined apparatus will likely improve measurement accuracy. In a typical plan, our study found that the ring surface dose can be 2.5 times larger than the point A prescription dose. EBT3 film can be used to monitor mucosal dose in brachytherapy treatments.

  18. Hydroxyl Radical Dosimetry for High Flux Hydroxyl Radical Protein Footprinting Applications Using a Simple Optical Detection Method

    Science.gov (United States)

    Xie, Boer; Sharp, Joshua S.

    2015-01-01

    Hydroxyl radical protein footprinting (HRPF) by Fast Photochemical Oxidation of Proteins (FPOP) is a powerful benchtop tool used to probe protein structure, interactions, and conformational changes in solution. However, the reproducibility of all HRPF techniques is limited by the ability to deliver a defined concentration of hydroxyl radicals to the protein. This ability is impacted by both the amount of radical generated and the presence of radical scavengers in solution. In order to compare HRPF data from sample to sample, a hydroxyl radical dosimeter is needed that can measure the effective concentration of radical that is delivered to the protein, after accounting for both differences in hydroxyl radical generation and non-analyte radical consumption. Here, we test three radical dosimeters (Alexa Fluor 488, terepthalic acid, and adenine) for their ability to quantitatively measure the effective radical dose under the high radical concentration conditions of FPOP. Adenine has a quantitative relationship between UV spectrophotometric response, effective hydroxyl radical dose delivered, and peptide and protein oxidation levels over the range of radical concentrations typically encountered in FPOP. The simplicity of an adenine-based dosimeter allows for convenient and flexible incorporation into FPOP applications, and the ability to accurately measure the delivered radical dose will enable reproducible and reliable FPOP across a variety of platforms and applications. PMID:26455423

  19. X-ray dose response of calcite—A comprehensive analysis for optimal application in TL dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kalita, J.M., E-mail: jitukalita09@gmail.com; Wary, G.

    2016-09-15

    Highlights: • Effect of annealing temperature on TL signal of calcite has been studied. • Specific annealing treatment for optimal dose response has been evaluated. • The dose response of natural calcite has been analyzed quantitatively. - Abstract: The effect of various annealing treatments on dosimetric characteristics of orange calcite (CaCO{sub 3}) mineral has been studied in detail. Quantitative analysis on the dose response shows that the 573 K annealed sample showed sublinear dose response from 10 mGy to 1 Gy. The fading and reproducibility of this sample are also good enough for dosimetric application. However, a specific annealing treatment after irradiation shows some significant improvements in the dosimetric characteristics of the sample. The 773 K pre-annealed sample, after X-ray irradiation post-annealing at 340 K for 6 min provides linear dose response from 10 mGy to 3.60 Gy, very less fading and good reproducibility. Moreover, this sample after post-annealing at 380 K for 6 min shows linear dose response from 10 mGy to 5.40 Gy when analyzed from the ∼408 K thermoluminescence (TL) glow peak. Analysis of TL glow curves confirmed that the 1.30 eV trap center in calcite crystal is the most effective trapping site for dosimetric application.

  20. Neutron beam measurement dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Amaro, C.R. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1995-11-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR.

  1. INDIVIDUAL DOSIMETRY SERVICE

    CERN Document Server

    1999-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact the Individual Dosimetry ServiceWe inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period JANUARY/FEBRUARY will be available from their usual dispatchers on Monday the third of January 2000.Please have your films changed:before the 12 January.The colour of the dosimeter valid in JANUARY/FEBRUARY is WHITE.

  2. Application of Texture Analysis to Study Small Vessel Disease and Blood–Brain Barrier Integrity

    Directory of Open Access Journals (Sweden)

    Maria del C. Valdés Hernández

    2017-07-01

    Full Text Available ObjectivesWe evaluate the alternative use of texture analysis for evaluating the role of blood–brain barrier (BBB in small vessel disease (SVD.MethodsWe used brain magnetic resonance imaging from 204 stroke patients, acquired before and 20 min after intravenous gadolinium administration. We segmented tissues, white matter hyperintensities (WMH and applied validated visual scores. We measured textural features in all tissues pre- and post-contrast and used ANCOVA to evaluate the effect of SVD indicators on the pre-/post-contrast change, Kruskal–Wallis for significance between patient groups and linear mixed models for pre-/post-contrast variations in cerebrospinal fluid (CSF with Fazekas scores.ResultsTextural “homogeneity” increase in normal tissues with higher presence of SVD indicators was consistently more overt than in abnormal tissues. Textural “homogeneity” increased with age, basal ganglia perivascular spaces scores (p < 0.01 and SVD scores (p < 0.05 and was significantly higher in hypertensive patients (p < 0.002 and lacunar stroke (p = 0.04. Hypertension (74% patients, WMH load (median = 1.5 ± 1.6% of intracranial volume, and age (mean = 65.6 years, SD = 11.3 predicted the pre/post-contrast change in normal white matter, WMH, and index stroke lesion. CSF signal increased with increasing SVD post-contrast.ConclusionA consistent general pattern of increasing textural “homogeneity” with increasing SVD and post-contrast change in CSF with increasing WMH suggest that texture analysis may be useful for the study of BBB integrity.

  3. Dosimetry: an ARDENT topic

    CERN Multimedia

    CERN Bulletin

    2012-01-01

    The first annual ARDENT workshop took place in Vienna from 20 to 23 November. The workshop gathered together the Early-Stage Researchers (ESR) and their supervisors, plus other people involved from all the participating institutions.   “The meeting, which was organised with the local support of the Austrian Institute of Technology, was a nice opportunity for the ESRs to get together, meet each other, and present their research plans and some preliminary results of their work,” says Marco Silari, a member of CERN Radiation Protection Group and the scientist in charge of the programme. Two full days were devoted to a training course on radiation dosimetry, delivered by renowned experts. The workshop closed with a half-day visit to the MedAustron facility in Wiener Neustadt. ARDENT (Advanced Radiation Dosimetry European Network Training) is a Marie Curie ITN project funded under EU FP7 with €4 million. The project focuses on radiation dosimetry exploiting se...

  4. Development of a New Positron Emission Tomography Tracer for Targeting Tumor Angiogenesis: Synthesis, Small Animal Imaging, and Radiation Dosimetry

    Directory of Open Access Journals (Sweden)

    David S. Lalush

    2013-05-01

    Full Text Available Angiogenesis plays a key role in cancer progression and correlates with disease aggressiveness and poor clinical outcomes. Affinity ligands discovered by screening phage display random peptide libraries can be engineered to molecularly target tumor blood vessels for noninvasive imaging and early detection of tumor aggressiveness. In this study, we tested the ability of a phage-display-selected peptide sequence recognizing specifically bone marrow- derived pro-angiogenic tumor-homing cells, the QFP-peptide, radiolabeled with 64Cu radioisotope to selectively image tumor vasculature in vivo by positron emission tomography (PET. To prepare the targeted PET tracer we modified QFP-phage with the DOTA chelator and radiolabeled the purified QFP-phage-DOTA intermediate with 64Cu to obtain QFP-targeted radioconjugate with high radiopharmaceutical yield and specific activity. We evaluated the new PET tracer in vivo in a subcutaneous (s.c. Lewis lung carcinoma (LLC mouse model and conducted tissue distribution, small animal PET/CT imaging study, autoradiography, histology, fluorescence imaging, and dosimetry assessments. The results from this study show that, in the context of the s.c. LLC immunocompetent mouse model, the QFP-tracer can target tumor blood vessels selectively. However, further optimization of the biodistribution and dosimetry profile of the tracer is necessary to ensure efficient radiopharmaceutical applications enabled by the biological specificity of the QFP-peptide.

  5. Applications of a statistical model to the dosimetry of brachytherapy linear sources; Aplicaciones de un modelo estadistico a la dosimetria dde fuentes de braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Sabariego, M. P.; Lallena, A. M.; Porras, I.

    2011-07-01

    The dosimetry of photon brachytherapy sources often make use of simple analytical expressions with free parameters to fit experimental data or Monte Carlo simulation. Some planning systems make use of polynomials yi o exponential functions. By applying a statistical model developed by the authors-point source of photons that provides these functions, we try to describe the dosimetric parameters that characterize the linear brachytherapy sources by integrating them.

  6. Radioembolization dosimetry : the road ahead

    NARCIS (Netherlands)

    Smits, Maarten L J; Elschot, Mattijs; Sze, Daniel Y; Kao, Yung H; Nijsen, JFW; Iagaru, Andre H; de Jong, Hugo W A M; van den Bosch, Maurice A A J; Lam, Marnix G E H

    Methods for calculating the activity to be administered during yttrium-90 radioembolization (RE) are largely based on empirical toxicity and efficacy analyses, rather than dosimetry. At the same time, it is recognized that treatment planning based on proper dosimetry is of vital importance for the

  7. Technical basis document for internal dosimetry

    CERN Document Server

    Hickman, D P

    1991-01-01

    This document provides the technical basis for the Chem-Nuclear Geotech (Geotech) internal dosimetry program. Geotech policy describes the intentions of the company in complying with radiation protection standards and the as low as reasonably achievable (ALARA) program. It uses this policy and applicable protection standards to derive acceptable methods and levels of bioassay to assure compliance. The models and computational methods used are described in detail within this document. FR-om these models, dose- conversion factors and derived limits are computed. These computations are then verified using existing documentation and verification information or by demonstration of the calculations used to obtain the dose-conversion factors and derived limits. Recommendations for methods of optimizing the internal dosimetry program to provide effective monitoring and dose assessment for workers are provided in the last section of this document. This document is intended to be used in establishing an accredited dosi...

  8. Absolute and relative dosimetry for ELIMED

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G. A. P.; Schillaci, F.; Scuderi, V. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Institute of Physics Czech Academy of Science, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic); Cuttone, G.; Candiano, G.; Musumarra, A.; Pisciotta, P.; Romano, F. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania (Italy); Carpinelli, M. [INFN Sezione di Cagliari, c/o Dipartimento di Fisica, Università di Cagliari, Cagliari (Italy); Leonora, E.; Randazzo, N. [INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Presti, D. Lo [INFN-Sezione di Catania, Via Santa Sofia 64, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Raffaele, L. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Tramontana, A. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Cirio, R.; Sacchi, R.; Monaco, V. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino, Italy and Università di Torino, Dipartimento di Fisica, Via P.Giuria, 1 10125 Torino (Italy); Marchetto, F.; Giordanengo, S. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino (Italy)

    2013-07-26

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  9. Neutron dosimetry: problems, solutions, prospects and the role of trace detectors; Dosimetria neutronica: problemas, soluciones, perspectivas y el papel de los detectores de traza

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, F. [Consejo de Seguridad Nuclear, Justo Dorado 11, 28040 Madrid (Spain)

    2009-10-15

    It is present in schematic way, the origin of the neutrons; their interaction with matter, until its application in the field of dosimetry. It describes some measuring instruments based on thermoluminescence dosimetry, some activation detectors and trace detectors. Finally, it summarizes the work in neutron dosimetry have been carried out at the Autonomous University of Barcelona. (Author)

  10. Thermocurrent dosimetry with high purity aluminum oxide

    Energy Technology Data Exchange (ETDEWEB)

    Fullerton, G.D.; Cameron, J.R.; Moran, P.R.

    1976-01-01

    The application of thermocurrent (TC) to ionizing radiation dosimetry was studied. It was shown that TC in alumina (Al/sub 2/O/sub 3/) has properties that are suited to personnel dosimetry and environmental monitoring. TC dosimeters were made from thin disks of alumina. Aluminum electrodes were evaporated on each side: on one face a high voltage electrode and on the opposite face a measuring electrode encircled by a guard ring. Exposure to ionizing radiation resulted in stored electrons and holes in metastable trapping sites. The signal was read-out by heating the dosimeter with a voltage source and picnometer connected in series between the opposite electrodes. The thermally remobilized charge caused a transient TC. The thermogram, TC versus time or temperature, is similar to a TL glow curve. Either the peak current or the integrated current is a measure of absorbed dose. Six grades of alumina were studied from a total of four commercial suppliers. All six materials displayed radiation induced TC signals. Sapphire of uv-grade quality from the Adolf Meller Co. (AM) had the best dosimetry properties of those investigated. Sources of interference were studied. Thermal fading, residual signal and radiation damage do not limit TC dosimetry. Ultraviolet light can induce a TC response but it is readily excluded with uv-opaque cladding. Improper surface preparation prior to electrode evaporation was shown to cause interference. A spurious TC signal resulted from polarization of surface contaminants. Spurious TC was reduced by improved cleaning prior to electrode application. Polished surfaces resulted in blocking electrodes and caused a sensitivity shift due to radiation induced thermally activated polarization. This was not observed with rough cut surfaces.

  11. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    by the research vessels RV Gaveshani and ORV Sagar Kanya are reported. The work carried out by the three charted ships is also recorded. A short note on cruise plans for the study of ferromanganese nodules is added...

  12. Temperature variations as a source of uncertainty in medical fiber-coupled organic plastic scintillator dosimetry

    DEFF Research Database (Denmark)

    Buranurak, Siritorn; Andersen, Claus Erik; Beierholm, Anders Ravnsborg

    2013-01-01

    Fiber-coupled organic plastic scintillators have potential applications in medical dosimetry related to, for example, brachytherapy and external beam radiotherapy with MV photons. As medical dosimetry generally strives for high accuracy, we designed a study to assess if the light yield from...

  13. Relocation of Dosimetry Service

    CERN Document Server

    2007-01-01

    The Dosimetry Service is moving from Building 24 to Building 55 and will therefore be closed on Friday, March 30. From Monday, April 2 onwards you will find us in building 55/1-001. Please note that during that day we might still have some problems with the internet connections and cannot fully guarantee normal service procedures. The service's opening hours and telephone number will not change as a result of the move 8.30 - 12.00, afternoons closed Tel. 72155

  14. 46 CFR 167.15-15 - Application for inspection of a new nautical school ship or a conversion of a vessel to a...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Application for inspection of a new nautical school ship or a conversion of a vessel to a nautical school ship. 167.15-15 Section 167.15-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Inspections § 167.15-15 Application for inspection of...

  15. Application Waste Sawdust as Mixed Polyurethane Insulation in Traditional Cold Storage of Fishing Vessel

    Directory of Open Access Journals (Sweden)

    Sutopo Purwono Fitri

    2017-03-01

    Full Text Available In the process of fishing it takes some supplies such as fishing equipment, instrumentation and storage of fish. The traditional fishermen of their fishing days fishing usually only bring ice cubes. Solid plastic polyurethane foam is a mixture solution of polyols and isocyanates, commonly used as an insulating material storage. From the observation waste generated being sawmill sawdust per spindle with diameter of 30 cm and a length of 1 m with 5 times sawmill, Saws 0.8 cm thick produced 0.0088 m³ / burnable logs only discarded. Therefore takes thermal conductivity test to review mixture of sawdust and polyurethane comparison with variations different dosing. Maximum disposals sawdust can be done is 40% of the total volume of material mixture, polyurethane and sawdust because composite material (sawdust-polyurethane can not be bond with good so easy slab separately from origin form. Thermal Conductivity insulating good and economical on disposals 40% wood flour (0.05252 W / m°C and is able to maintain a 2 kg of ice crystals melt up perfect on 34 hours. Operating profits economical from 4,8 m³insulation composite application with obtained Rp 4.486.000 compared with 100% Polyurethane Insulation Manufacture.

  16. Assessment of Negligible Creep, Off-Normal Welding and Heat Treatment of Gr91 Steel for Nuclear Reactor Pressure Vessel Application

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Weiju [ORNL; Terry, Totemeier [Idaho National Laboratory (INL)

    2006-10-01

    Two different topics of Grade 91 steel are investigated for Gen IV nuclear reactor pressure vessel application. On the first topic, negligible creep of Grade 91 is investigated with the motivation to design the reactor pressure vessel in negligible creep regime and eliminate costly surveillance programs during the reactor operation. Available negligible creep criteria and creep strain laws are reviewed, and new data needs are evaluated. It is concluded that modifications of the existing criteria and laws, together with their associated parameters, are needed before they can be reliably applied to Grade 91 for negligible creep prediction and reactor pressure vessel design. On the second topic, effects of off-normal welding and heat treatment on creep behavior of Grade 91 are studied with the motivation to better define the control over the parameters in welding and heat treatment procedures. The study is focused on off-normal austenitizing temperatures and improper cooling after welding but prior to post-weld heat treatment.

  17. Hanford Internal Dosimetry Project manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Carbaugh, E.H.; Bihl, D.E.; MacLellan, J.A.; Long, M.P.

    1994-07-01

    This document describes the Hanford Internal Dosimetry Project, as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy and its Hanford contractors. Project services include administrating the bioassay monitoring program, evaluating and documenting assessment of potential intakes and internal dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. Specific chapters deal with the following subjects: practices of the project, including interpretation of applicable DOE Orders, regulations, and guidance into criteria for assessment, documentation, and reporting of doses; assessment of internal dose, including summary explanations of when and how assessments are performed; recording and reporting practices for internal dose; selection of workers for bioassay monitoring and establishment of type and frequency of bioassay measurements; capability and scheduling of bioassay monitoring services; recommended dosimetry response to potential internal exposure incidents; quality control and quality assurance provisions of the program.

  18. Diagnostic radiology dosimetry: status and trends

    Energy Technology Data Exchange (ETDEWEB)

    Rivera M, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    Full text: Medical radiation is by far the largest man-made source of public exposure to ionizing radiation. Since 1970 the expression of protection standards shifted from a dose- to a risk-based approach, with dose limits established to yield risks to radiation workers comparable with those for workers in other safe industries. Another hand, worldwide interest in patient dose measurement was stimulated by the publication of Patient Dose Reduction in Diagnostic Radiology by the UK National Radiological Protection Board (NRPB). In response to heightened awareness of the importance of patient dose contributed by radiology procedures, there has been a general trend to effect control of patient doses by applying the principles of optimization coupled with an increase in regulatory enforcement. In this sense, thermoluminescent dosimetry (TLD) has been actively proposed in the last 3 decades thanks to their successful applications in diagnostic radiology. At the same time, it is emerged as the best radiation dosimetry method. The present work presents advantages of thermoluminescent dosimetry for X-ray beams measurements and its optimization. (Author)

  19. Chromosomal analysis and application of biological dosimetry in two cases of apparent over exposure; Analisis cromosomico y aplicacion de la dosimetria biologica en dos casos de aparente sobreexposicion

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Brena V, M. [Departamento de Biologia, ININ A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The gamma radiation calibration curve of {sup 60} Co is used which was generated in the ININ Laboratory of Biology to calculate the exposure dose of two workers whose dosemeters marked values above of the limit allowed. The analysis indicates that in a first case, the aberrations frequency corresponded to the basal value, therefore there is not over exposure. The aberrations frequency of the second case is lightly above to the basal value and therefore the probability favors to what the physical dosimetry indicates. (Author)

  20. Application of numerical analysis in personal dosimetry by thermoluminescent; Aplicacion de metodos de analisis numerico en un sistema de dosimetria personal por termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Ros, J. M.; Delgado, A.; Fantuzzi, E.

    2003-07-01

    The main features of the methods for computerised glow curve analysis are presented in this communication together with a description of their advantages for TLD in replacement of standard procedures. A protocol for the employment of different kinds of computerised methods for personal dosimetry is proposed. The new results now presented demonstrate the possibility, using a very simple computerised analysis, of working with LiF GR-200 without any pre-heat or annealing simplifying the working procedures, now reduced to the simplest possible: a single step readout up to 240 degree celsius. (Author) 7 refs.

  1. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    Please note the following opening hours of the Service: From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  2. MO-B-BRB-01: 3D Dosimetry in the Clinic: Background and Motivation

    Energy Technology Data Exchange (ETDEWEB)

    Schreiner, L. [Cancer Center of Southeastern Ontario (Canada)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  3. MO-B-BRB-03: 3D Dosimetry in the Clinic: Validating Special Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Juang, T. [Stanford Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  4. MO-B-BRB-02: 3D Dosimetry in the Clinic: IMRT Technique Validation in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Ceberg, S. [Lund University (Sweden)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  5. On The Application of Flow Forming to the Fabrication of Type B Radioactive Material Package Containment Vessels, Rev. 1

    Energy Technology Data Exchange (ETDEWEB)

    Mok, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); DeMicco, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fischer, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hagler, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Russell, E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wen, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hafner, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Anderson, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-07-02

    Flow forming is a modernized and improved version of metal spinning, which is one of the oldest methods of chipless forming. The metal spinning method used a pivoted pointer to manually push a metal sheet mounted at one end of a spinning mandrel. As a result, the modernized version of metal spinning, i.e. flow forming evolved. The recent proposal in the radioactive material (RAM) packaging community to use flow forming for mass production of small containment vessels for drum packages is a natural continuation of the trend. We will discuss how the vessel can have the special material properties and stabilities required for a RAM containment vessel.

  6. BeOSL system for personal dosimetry : dosimetric characteristics and practical application; Sistema BeOSL para dosimetria personal : caracteristicas dosimetricas y la aplicacion practica

    Energy Technology Data Exchange (ETDEWEB)

    Mende, E. [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, Working Group Engineering, D-85764 Neuherberg (Germany)

    2015-10-15

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  7. Relationship between student selection criteria and learner success for medical dosimetry students

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Jamie, E-mail: jabaker@mdanderson.org [Medical Dosimetry Program, School of Health Professions, The University of Texas MD Anderson Cancer Center School of Health Professions, Houston, TX (United States); Tucker, Debra [Arizona State University, Phoenix, AZ (United States); Raynes, Edilberto [University of Phoenix, Phoenix, AZ (United States); Aitken, Florence [University of Nevada, Las Vegas, NV (United States); Allen, Pamela [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2016-04-01

    Medical dosimetry education occupies a specialized branch of allied health higher education. Noted international shortages of health care workers, reduced university funding, limitations on faculty staffing, trends in learner attrition, and increased enrollment of nontraditional students force medical dosimetry educational leadership to reevaluate current admission practices. Program officials wish to select medical dosimetry students with the best chances of successful graduation. The purpose of the quantitative ex post facto correlation study was to investigate the relationship between applicant characteristics (cumulative undergraduate grade point average (GPA), science grade point average (SGPA), prior experience as a radiation therapist, and previous academic degrees) and the successful completion of a medical dosimetry program, as measured by graduation. A key finding from the quantitative study was the statistically significant positive correlation between a student's previous degree and his or her successful graduation from the medical dosimetry program. Future research investigations could include a larger research sample, representative of more medical dosimetry student populations, and additional studies concerning the relationship of previous work as a radiation therapist and the effect on success as a medical dosimetry student. Based on the quantitative correlation analysis, medical dosimetry leadership on admissions committees could revise student selection rubrics to place less emphasis on an applicant's undergraduate cumulative GPA and increase the weight assigned to previous degrees.

  8. Thermoluminescence of metal oxides and its applications to the dosimetry of low energy ionizing radiation; Termoluminiscencia de oxidos metalicos y su aplicacion a la dosimetria de la radiacion ionizante de baja energia

    Energy Technology Data Exchange (ETDEWEB)

    Azorin N, J. [CICATA-IPN, 11500 Mexico D.F. (Mexico); Rivera M, T. [Universidad Autonoma Metropolitana-Iztapalapa, 09340 Mexico D.F. (Mexico); Falcony G, C. [CINVESTAV-IPN, DEpartamento de Fisica, 07300 Mexico D.F. (Mexico); Martinez S, E.; Garcia H, M. [Universidad Nacional Autonoma de Mexico, Instituto de Investigaciones en Materiales, 04510 Mexico D.F. (Mexico)

    1999-07-01

    There are presented the results obtained since 1997 at present in the project Study of the thermoluminescence of metal oxides and its applications to the dosimetry of ionizing radiation. Its have been developed ZrO{sub 2} films without doping and doped with Eu, Tb, and Mn as well as Al{sub 2}O{sub 3} films without doping and doped with Na. The results obtained to the irradiated films of ZrO{sub 2} with ultraviolet and visible lights have been satisfactory. The Al{sub 2}O{sub 3} in film form showed to be a promising material for the measuring ultraviolet light and the pellets of ZrO{sub 2} + Ptfe for X-rays and low energy gamma rays. (Author)

  9. Internal dosimetry technical basis manual

    Energy Technology Data Exchange (ETDEWEB)

    1990-12-20

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.

  10. Medical dosimetry in Hungary

    Science.gov (United States)

    Turák, O.; Osvay, M.; Ballay, L.

    2012-09-01

    Radiation exposure of medical staff during cardiological and radiological procedures was investigated. The exposure of medical staff is directly connected to patient exposure. The aim of this study was to determine the distribution of doses on uncovered part of body of medical staff using LiF thermoluminescent (TL) dosimeters in seven locations. Individual Kodak film dosimeters (as authorized dosimetry system) were used for the assessment of medical staff's effective dose. Results achieved on dose distribution measurements confirm that wearing only one film badge under the lead apron does not provide enough information on the personal dose. The value of estimated annual doses on eye lens and extremities (fingers) were in good correlation with international publications.

  11. Strahlungsmessung und Dosimetrie

    CERN Document Server

    Krieger, Hanno

    2013-01-01

    „Strahlungsquellen und Dosimetrie“ ist Teil einer Lehrbuchreihe zur Strahlungsphysik und zum Strahlenschutz. Der erste Teil befasst sich mit den physikalischen Grundlagen der Strahlungsdetektoren und der Strahlungsmessung. Im zweiten Teil werden die Konzepte und Verfahren der klinischen Dosimetrie dargestellt. Der dritte Abschnitt erläutert ausführlich die Dosisverteilungen der klinisch angewendeten Strahlungsarten. Im vierten Teil werden weitere Messaufgaben der Strahlungsphysik einschließlich der Messsysteme für die Bildgebung mit Röntgenstrahlung dargestellt. Neben den grundlegenden Ausführungen enthält dieser Band im laufenden Text zahlreiche Tabellen und Grafiken zur technischen und medizinischen Radiologie, die bei der praktischen Arbeit sehr hilfreich sein können und 199 Übungsaufgaben mit Lösungen zur Vertiefung der Inhalte. Für die zweite Auflage wurden die Darstellungen der Elektronen- und der Protonendosimetrie sowie der bildgebenden Verfahren mit Computertomografen deutlich erweit...

  12. Dosimetry of high energy radiation

    CERN Document Server

    Sahare, P D

    2018-01-01

    High energy radiation is hazardous to living beings and a threat to mankind. The correct estimation of the high energy radiation is a must and a single technique may not be very successful. The process of estimating the dose (the absorbed energy that could cause damages) is called dosimetry. This book covers the basic technical knowledge in the field of radiation dosimetry. It also makes readers aware of the dangers and hazards of high energy radiation.

  13. Dosimetry analysis of distributions radials dose profiles of {sup 90}Sr + {sup 90}Y beta therapy applicators using the MCNP-4C code and radio chromium films; Analise dosimetrica de perfis de distribuicoes radias de doses relativas de um aplicador de betaterapia de {sup 90}Sr + {sup 90}Y utilizando o codigo MCNP-4C e filmes radiocromicos

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Talita S.; Yoriyaz, Helio [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Fernandes, Marco A.R., E-mail: tasallesc@gmail.co [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina. Servico de Radioterapia; Louzada, Mario J.Q. [UNESP, Aracatuba, SP (Brazil). Curso de Medicina Veterinaria

    2011-07-01

    Although they are no longer manufactured, the applicators of {sup 90}Sr + {sup 90}Y acquired in the decades of 1990 are still in use, by having half-life of 28.5 years. These applicators have calibration certificate given by their manufacturers, where few have been re calibrated. Thus it becomes necessary to accomplish thorough dosimetry of these applicators. This paper presents a dosimetric analysis distribution radial dose profiles for emitted by an {sup 90}Sr + {sup 90}Y beta therapy applicator, using the MCNP-4C code to simulate the distribution radial dose profiles and radio chromium films to get them experimentally . The results with the simulated values were compared with the results of experimental measurements, where both curves show similar behavior, which may validate the use of MCNP-4C and radio chromium films for this type of dosimetry. (author)

  14. Dosimetry analysis of distribution radial dose profiles of {sup 90}Sr + {sup 90}Y beta therapy applicators using the MCNP-4C code and radio chromium films; Analise dosimetrica de perfis de distribuicoes radiais de doses relativas de um aplicador de betaterapia de {sup 90}Sr + {sup 90}Y utilizando o codigo MCNP-4C e filmes radiocromicos

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, T.S.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Fernandes, M.A.R. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Fac. de Medicina. Servico de Radioterapia; Louzada, M.J.Q. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Aracatuba, SP (Brazil). Curso de Medicina Veterinaria

    2010-07-01

    Although they are no longer manufactured, the applicators of {sup 90}Sr +{sup 90}Y acquired in the decades of 1990 are still in use, by having half-life of 28.5 years. These applicators have calibration certificate given by their manufacturers, where few have been recalibrated. Thus it becomes necessary to accomplish thorough dosimetry of these applicators. This paper presents a dosimetric analysis distribution radial dose profiles for emitted by an {sup 90}Sr+{sup 90}Y beta therapy applicator, using the MCNP-4C code to simulate the distribution radial dose profiles and radiochromium films to get them experimentally . The results with the simulated values were compared with the results of experimental measurements, where both curves show similar behavior, which may validate the use of MCNP-4C and radiochromium films for this type of dosimetry. (author)

  15. Tetrazolium salt monomers for gel dosimetry I: Principles

    Science.gov (United States)

    Penev, Kalin I.; Wang, Meng; Mequanint, Kibret

    2017-05-01

    Tetrazolium salts (TS) have been previously used for radiochromic dosimetry in solutions, films and three dimensional (3D) gelatine-based gels. However, widespread application for 3D dosimetry has not been achieved due to the required high concentrations and associated high costs of the TS dimer used in prior research. Through careful selection of TS monomer, sensitivity-enhancing additives and inert gel forming material, we report the preparation of a non-diffusing, chemically stable, 3D dosimeter with linear sensitivity between 0 and 80 Gy with submillimolar requirements for the active TS.

  16. RCT: Module 2.04, Dosimetry, Course 8769

    Energy Technology Data Exchange (ETDEWEB)

    Hillmer, Kurt T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-11

    This course will introduce the types of instruments used to measure external and internal radiation to people. Dosimetry is the quantitative assessment of radiation received by the human body. Several types of dosimeters are used worldwide. This information is valuable to all radiological control personnel because dosimeters are the only direct method to measure and document personnel radiation exposure and ensure regulatory compliance with applicable limits. This course will cover dosimetry terms, Department of Energy (DOE) limits, Los Alamos National Laboratory (LANL) administrative guidelines, thermoluminescent dosimeters (TLDs), LANL dosimetry, and bioassay assessment methods. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and providing in-thefield skills.

  17. Dosimetry in clinical static magnetic fields using plastic scintillation detectors

    DEFF Research Database (Denmark)

    Stefanowicz, S.; Latzel, H.; Lindvold, Lars René

    2013-01-01

    To further improve the accuracy of dose delivery to the patient, several projects are pursuing the integration of linear accelerators with magnetic resonance imaging systems. Generally, this is conceived as the next generation of image-guided radiotherapy. For technical and physical reason it is......, however, not clear yet how dosimetry will be conducted as standard methods and might not be easily transferred to systems with clinical magnetic fields. For dosimetry in MRI accelerators, we have tested plastic scintillation detectors (PSD) coupled to optical fibers. They are suitable for real-time and in......-vivo dosimetry in radiation treatments and diagnostics and could be, being all-optical, promising candidates for this application. To study the basic feasibility of using PSDs with organic scintillators in magnetic fields, we measured the response of these dosimeters in presence of magnetic fields up to 1 T...

  18. Applied physics of external radiation exposure dosimetry and radiation protection

    CERN Document Server

    Antoni, Rodolphe

    2017-01-01

    This book describes the interaction of living matter with photons, neutrons, charged particles, electrons and ions. The authors are specialists in the field of radiation protection. The book synthesizes many years of experiments with external radiation exposure in the fields of dosimetry and radiation shielding in medical, industrial and research fields. It presents the basic physical concepts including dosimetry and offers a number of tools to be used by students, engineers and technicians to assess the radiological risk and the means to avoid them by calculating the appropriate shields. The theory of radiation interaction in matter is presented together with empirical formulas and abacus. Numerous numerical applications are treated to illustrate the different topics. The state of the art in radiation protection and dosimetry is presented in detail, especially in the field of simulation codes for external exposure to radiation, medical projects and advanced research. Moreover, important data spread in differ...

  19. Graphite mixed magnesium borate TL dosemeters for beta ray dosimetry

    DEFF Research Database (Denmark)

    Prokic, M; Christensen, Poul

    1984-01-01

    Sintered MgB4O7:Dy dosemeters with graphite contents from 1 to 10% were investigated for application for personnel dosimetry. Data are given on dose response, dose threshold, reproducibility, beta energy response and fading. Furthermore, results from practical field experiments are presented...

  20. Optically stimulated luminescence dosimetry using natural and synthetic materials

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; McKeever, S.W.S.

    1996-01-01

    The application of optically stimulated luminescence (OSL) for use in radiation dosimetry is reviewed. A broad description is given of OSL techniques developed at Riso National Laboratory and at Oklahoma State University, and recent collaborative investigations on the properties of a variety...

  1. Cell culture for three-dimensional modeling in rotating-wall vessels: an application of simulated microgravity

    Science.gov (United States)

    Schwarz, R. P.; Goodwin, T. J.; Wolf, D. A.

    1992-01-01

    High-density, three-dimensional cell cultures are difficult to grow in vitro. The rotating-wall vessel (RWV) described here has cultured BHK-21 cells to a density of 1.1 X 10(7) cells/ml. Cells on microcarriers were observed to grow with enhanced bridging in this batch culture system. The RWV is a horizontally rotated tissue culture vessel with silicon membrane oxygenation. This design results in a low-turbulence, low-shear cell culture environment with abundant oxygenation. The RWV has the potential to culture a wide variety of normal and neoplastic cells.

  2. In vivo dosimetry with thermoluminescent dosimeters in external photon beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Alessandro M. [Departamento de Fisica e Matematica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, SP (Brazil)], E-mail: amcosta@usp.br; Barbi, Gustavo L.; Bertucci, Edenyse C.; Ferreira, Heberton; Sansavino, Simone Z.; Colenci, Beatriz [Servico de Radioterapia, Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, Universidade de Sao Paulo, Av. Bandeirantes 3900, 14048-900 Ribeirao Preto, SP (Brazil); Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)

    2010-04-15

    The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatment verification method and its applicability as a part of a quality assurance program in radiotherapy.

  3. Studies in Ultrasonic Dosimetry.

    Science.gov (United States)

    Zitouni, Abderrachid

    The widespread use of ultrasonic devices in both industry and medicine confirms the great importance of ultrasound as a source of nonionizing radiation. The biological effects of this type of radiation are not completely known up to today, and the need for proper dosimetry is evident. Previous work in the field has been limited to the determination of ultrasonic energy deposition by attenuation measurements of traveling sound waves in homogenized specimens. Alternatively, observed effects were correlated to the output of the source. The objective of this work was to correlate the absorption properties of sound absorbing media to their elastic properties and deduce a correlation between the sonic absorption coefficient and the corresponding Young's modulus. Energy deposition measurements were performed in isotropic rubber samples and in anisotropic meat specimens by the use of the thermocouple probe method which measures the absorbed energy directly. Elasticity measurements were performed for the different types of materials used. The Young's modulus for each type was deduced from defletion measurements on rectangular strips when subjected to successive forces of varying magnitude. The final experimental results showed the existence of a linear relationship between the absorption coefficient of a given elastic material and the inverse square root of its Young's modulus.

  4. For information: Individual dosimetry service

    CERN Multimedia

    2004-01-01

    The service has noticed that there are dosimeter holders who have changed their activities and thus have no longer need of dosimeter as a permanent basis in their work (persons who go rarely to the controlled areas). The reduction of persons in the regular distribution list of dosimeters will lighten the work of the service (distribution, evaluation and consolidation of doses) as well as the work of the distributors, needless to say the economical input this would have for CERN. For the persons who only need a dosimeter temporarily we would like to remind that there is a quick and simple procedure to have one immediately from the Individual Dosimetry Service. Please contact the service (dosimetry.service@cern.ch) if you do not need a dosimeter regularly. Thank you for your cooperation. http://cern.ch/rp-dosimetry

  5. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    Please note the following opening hours of the Service: In June: Every morning from 8:30 to 12:00 In July: Mondays, Wednesdays and Fridays from 8:30 to 11:30 Closed all day on Tuesdays and Thursdays From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  6. Dosimetry of radium-223 and progeny

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, D.R. [Pacific Northwest National Lab., Richland, WA (United States); Sgouros, G. [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    1999-01-01

    Radium-223 is a short-lived (11.4 d) alpha emitter with potential applications in radioimmunotherapy of cancer. Radium-223 can be complexed and linked to protein delivery molecules for specific tumor-cell targeting. It decays through a cascade of short-lived alpha- and beta-emitting daughters with emission of about 28 MeV of energy through complete decay. The first three alpha particles are essentially instantaneous. Photons associated with Ra-223 and progeny provide the means for tumor and normal-organ imaging and dosimetry. Two beta particles provide additional therapeutic value. Radium-223 may be produced economically and in sufficient amounts for widescale application. Many aspects of the chemistry of carrier-free isotope preparation, complexation, and linkage to the antibody have been developed and are being tested. The radiation dosimetry of a Ra-223-labeled antibody shows favorable tumor to normal tissue dose ratios for therapy. The 11.4-d half-life of Ra-223 allows sufficient time for immunoconjugate preparation, administration, and tumor localization by carrier antibodies before significant radiological decay takes place. If 0.01 percent of a 37 MBq (1 mCi) injection deposits in a one gram tumor mass, and if the activity is retained with a typical effective half-time (75 h), the absorbed dose will be 163 mGy MBq{sup {minus}1} (600 rad mCi{sup {minus}1}) administered. 49 refs., 5 figs., 2 tabs.

  7. Fabrication and electrical characterization of polyaniline-silicon heterojunction for gamma radiation dosimetry application; Fabricacao e caracterizacao eletrica de heterojuncoes de polianilina - silicio para aplicacao em dosimetria de radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Laranjeira, Jane Maria Goncalves

    2004-08-15

    In this work a technique has been developed to fabricate high quality polyaniline-silicon heterojunction diodes for use as gas and/or ionizing radiation sensors. Polyaniline thin films (40 nm thick) produced by spin-coating on silicon substrates, were the active part of the junction structure. The devices presented excellent reproducibility of their electrical characteristics with high rectification ratio, 60,000 at {+-}1.0 V, and typical reverse current at - 1.0 V of 3 nA at 295 K. A G/I x G plot has been used to analyze the current-voltage characteristics, yielding typical series resistance of 4 k{omega} {+-} 5% and ideality factor in a range of 1,9 {+-} 0.5%. The heterojunction diode presents high sensitivity to gamma radiation in the dose range of 3 x 10{sup -2} to 7 kGy with a linear response in the forward and reverse bias. The excellent electrical characteristics together with the linear response with the dose, strongly suggest the application of this device for spectrometry or dosimetry of high doses of gamma radiation. These devices presented high sensitivity to gas moistures such as ammonia, nitric acid and trichloroethylene. In both cases the sensitivity was observed through shifts of the current-voltage curves, which can be easily monitored to provide a calibration curve of the sensor either as a radiation dosimeter or as a gas sensor for use in applications for gas monitoring or radiation dosimetry. Several aspects of the reliability physics of silicon-polyaniline heterojunction, such as degradation effects induced by local heating, charge trapping and temperature changes, have been discussed. These results further confirm the quality of the devices electrical characteristics and their suitability for radiation and gas sensors applications. Another interesting results presented in this work was the use of polyemeraldine nanofilms (thickness in the range 30-50 nm) deposited by 'spin coating' on glass substrates as an optical dosimeter for

  8. Radiation chemical dosimetry by means of nitrate-nitrite; Dosimetria quimica de la radiacion aplicacion del sistema nitrato-nitrito

    Energy Technology Data Exchange (ETDEWEB)

    Tormo Ferrero, M. J.

    1977-07-01

    The different chemical systems used in dosimetry and the selection criteria for them are described. The general topics in dosimetry with alkali nitrates as well as the phenomena occurring in their radiolysis are also treated. The possibility of application in dosimetric areas useful in radiosterilization and industrial processes is studied too. (Author) 22 refs.

  9. Development and application of a set of mesh-based and age-dependent Chinese family phantoms for radiation protection dosimetry: Preliminary Data for external photon beams

    Science.gov (United States)

    Pi, Yifei; Zhang, Lian; Huo, Wanli; Feng, Mang; Chen, Zhi; Xu, X. George

    2017-09-01

    A group of mesh-based and age-dependent family phantoms for Chinese populations were developed in this study. We implemented a method for deforming original RPI-AM and RPI-AF models into phantoms of different ages: 5, 10 ,15 and adult. More than 120 organs for each model were processed to match with the values of the Chinese reference parameters within 0.5%. All of these phantoms were then converted to voxel format for Monte Carlo simulations. Dose coefficients for adult models were counted to compare with those of RPI-AM and RPI-AF. The results show that there are significant differences between absorbed doses of RPI phantoms and these of our adult phantoms at low energies. Comparisons for the dose coefficients among different ages and genders were also made. it was found that teenagers receive more radiation doses than adults under the same irradiation condition. This set of phantoms can be utilized to estimate dosimetry for Chinese population for radiation protection, medical imaging, and radiotherapy.

  10. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    CERN Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page http://cern.ch/rp-dosimetry. The Dosimetry Service is open every morning from 8.30 - 12.00, and closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats.

  11. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    CERN Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry. The Dosimetry Service is open every morning from 8.30 to 12.00 and is closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats.

  12. 50 CFR 665.16 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel identification. 665.16 Section 665... identification. (a) Applicability. Each fishing vessel subject to this part, except those identified in paragraph (e) of this section, must be marked for identification purposes, as follows: (1) A vessel that is...

  13. Characterization of jade and silicates of the jade family for application in radiation dosimetry; Caracterizacao do jade e dos silicatos da familia do jade para aplicacao em dosimetria das radiacoes

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Adeilson Pessoa de

    2007-07-01

    The main dosimetric properties of jade and of Brazilian silicates of the jade family were studied for application in radiation dosimetry of high doses. Jade is a common denomination of two different silicates: jadeite, Na Al(Si{sub 2}O{sub 6}), and nephrite, Ca{sub 2}(Mg, Fe){sub 5}(Si{sub 4}O{sub 11}){sub 2} (OH){sub 2}, that belong to the subclasses of the pyroxenes and amphiboles respectively. The jade samples studied in this work were from: Austria, New Zealand, United States and Brazil. The Brazilian silicates of the jade family studied in this work were the amphiboles: tremolite,Ca{sub 2}Mg{sub 5}(Si{sub 4}O{sub 11}){sub 2}(OH){sub 2} e actinolite, Ca{sub 2}Fe{sub 5}(Si{sub 4}O{sub 11}){sub 2}(OH){sub 2}; and the pyroxenes: rhodonite, MnSiO{sub 3} and diopside, Ca Mg(Si{sub 2}O{sub 6}). The mineralogical and chemical composition of these materials were obtained using the neutron activation analysis and X-ray diffraction techniques. The main dosimetric properties (emission curves, calibration curves, reproducibility, lower detection limits, angular and energy dependence, etc) were studied using the thermoluminescent (T L), thermally stimulated exo-emission (TSEE) and electronic paramagnetic resonance (EPR) techniques. The jade-Teflon and the silicate-Teflon samples present two T L peaks around 115 deg C (peak 1) and 210 deg C (peak 2). The calibration curves of the studied materials present a linear behaviour between 0.5 Gy and 1 kGy. The TSEE emission peak occurs at 240 deg C for all samples, and the calibration curves present a sub linear behaviour between 100 Gy and 20 kGy. In the case of the EPR technique, only jade USA has a potential application for radiation dosimetry. A static computational simulation of the most probable intrinsic and extrinsic defects in rhodonite was also realized. Among the basic defects, the Schottky defects of rhodonite are the most probable to occur and, among the extrinsic defects, the divalent and trivalent dopants present the

  14. Development and application of a dosimetry model (ExDoM2) for calculating internal dose of specific particle-bound metals in the human body.

    Science.gov (United States)

    Chalvatzaki, Eleftheria; Lazaridis, Mihalis

    2015-01-01

    The objective of the current study was to develop a dosimetry model (ExDoM2) for calculating internal dose of specific particle-bound metals (As, Pb, Cd, Cr and Mn) in the human body. The ExDoM2 is a revised version of a respiratory tract model (ExDoM) incorporating a new particle clearance mechanism in the respiratory tract model and a Physiologically-Based PharmacoKinetic (PBPK) model. The revised respiratory tract model was used to calculate the deposition, clearance and retention of particles in the human respiratory tract and the mass transferred to the oesophagus (gastrointestinal tract) and blood. The PBPK module was used to analyze the distribution of metals (As, Pb, Cd, Cr and Mn) from the blood circulation system to other organs or tissues like liver, kidneys, heart, brain, muscle and bone. The model was applied to calculate the internal human dose for an adult Caucasian male exposed to particulate mass matter (PM), PMPb, PMCd, PMMn and PMCr in an urban area (Athens, Greece). The analysis showed that at the end of the exposure (one day exposure scenario) to PMPb, the major accumulation occurs in the bone, blood and muscle, whereas as regards PMCd the major accumulation occurs in the other tissues, like kidney and liver. In addition, for PMMn, the major accumulation occurs in the other tissues and lungs, whereas as regards PMCr the major accumulation occurs in the gastrointestinal (GI) tract and lungs. Therefore, ExDoM2 is an important feature in studying deposition of particles in the human body.

  15. SU-D-19A-05: The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Simiele, S; Micka, J; Culberson, W; DeWerd, L [University of WI-Madison/ADCL, Madison, WI (United States)

    2014-06-01

    Purpose: A full TG-43 dosimetric characterization has not been performed for the Xoft Axxent ® electronic brachytherapy source (Xoft, a subsidiary of iCAD, San Jose, CA) within the Xoft 30 mm diameter vaginal applicator. Currently, dose calculations are performed using the bare-source TG-43 parameters and do not account for the presence of the applicator. This work focuses on determining the difference between the bare-source and sourcein- applicator TG-43 parameters. Both the radial dose function (RDF) and polar anisotropy function (PAF) were computationally determined for the source-in-applicator and bare-source models to determine the impact of using the bare-source dosimetry data. Methods: MCNP5 was used to model the source and the Xoft 30 mm diameter vaginal applicator. All simulations were performed using 0.84p and 0.03e cross section libraries. All models were developed based on specifications provided by Xoft. The applicator is made of a proprietary polymer material and simulations were performed using the most conservative chemical composition. An F6 collision-kerma tally was used to determine the RDF and PAF values in water at various dwell positions. The RDF values were normalized to 2.0 cm from the source to accommodate the applicator radius. Source-in-applicator results were compared with bare-source results from this work as well as published baresource results. Results: For a 0 mm source pullback distance, the updated bare-source model and source-in-applicator RDF values differ by 2% at 3 cm and 4% at 5 cm. The largest PAF disagreements were observed at the distal end of the source and applicator with up to 17% disagreement at 2 cm and 8% at 8 cm. The bare-source model had RDF values within 2.6% of the published TG-43 data and PAF results within 7.2% at 2 cm. Conclusion: Results indicate that notable differences exist between the bare-source and source-in-applicator TG-43 simulated parameters. Xoft Inc. provided partial funding for this work.

  16. In aqua vivo EPID dosimetry

    NARCIS (Netherlands)

    Wendling, Markus; McDermott, Leah N.; Mans, Anton; Olaciregui-Ruiz, Ígor; Pecharromán-Gallego, Raul; Sonke, Jan-Jakob; Stroom, Joep; van Herk, Marcel; Mijnheer, Ben J.

    2012-01-01

    At the Netherlands Cancer Institute--Antoni van Leeuwenhoek Hospital in vivo dosimetry using an electronic portal imaging device (EPID) has been implemented for almost all high-energy photon treatments of cancer with curative intent. Lung cancer treatments were initially excluded, because the

  17. Portal dosimetry in wedged beams

    NARCIS (Netherlands)

    Spreeuw, H.; Rozendaal, R.; Camargo, P.; Mans, A.; Wendling, M.; Olaciregui-Ruiz, I.; Sonke, J.J.; Herk, M. van; Mijnheer, B.

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the

  18. Radiation dosimetry by potassium feldspar

    Indian Academy of Sciences (India)

    Unknown

    Radiation dosimetry by potassium feldspar. ARUN PANDYA*, S G VAIJAPURKAR and P K BHATNAGAR. Defence Laboratory, Jodhpur 342 011, India. MS received 12 July 1999; revised 15 February 2000. Abstract. The thermoluminescence (TL) properties of raw and annealed feldspar have been studied for their.

  19. Radiation dosimetry by potassium feldspar

    Indian Academy of Sciences (India)

    The thermoluminescence (TL) properties of raw and annealed feldspar have been studied for their use in gamma dosimetry. The raw gamma exposed feldspar shows glow peaks at 120°C and 319°C. Gamma dose beyond 500 cGy can be measured without any significant fading even after 40 days of termination of ...

  20. Monte Carlo simulations for heavy ion dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Geithner, O.

    2006-07-26

    Water-to-air stopping power ratio (s{sub w,air}) calculations for the ionization chamber dosimetry of clinically relevant ion beams with initial energies from 50 to 450 MeV/u have been performed using the Monte Carlo technique. To simulate the transport of a particle in water the computer code SHIELD-HIT v2 was used which is a substantially modified version of its predecessor SHIELD-HIT v1. The code was partially rewritten, replacing formerly used single precision variables with double precision variables. The lowest particle transport specific energy was decreased from 1 MeV/u down to 10 keV/u by modifying the Bethe- Bloch formula, thus widening its range for medical dosimetry applications. Optional MSTAR and ICRU-73 stopping power data were included. The fragmentation model was verified using all available experimental data and some parameters were adjusted. The present code version shows excellent agreement with experimental data. Additional to the calculations of stopping power ratios, s{sub w,air}, the influence of fragments and I-values on s{sub w,air} for carbon ion beams was investigated. The value of s{sub w,air} deviates as much as 2.3% at the Bragg peak from the recommended by TRS-398 constant value of 1.130 for an energy of 50 MeV/u. (orig.)

  1. Clinical radionuclide therapy dosimetry: the quest for the ''Holy Gray''

    Energy Technology Data Exchange (ETDEWEB)

    Brans, B. [University Hospital Maastricht, Department of Nuclear Medicine, P.O. Box 5800, Maastricht (Netherlands); Bodei, L. [Istituto Europeo di Oncologia, Division of Nuclear Medicine, Milan (Italy); Giammarile, F. [Service de Medecine Nucleaire, Centre Leon Berard, Lyon (France); Linden, O.; Tennvall, J. [Lund University Hospital, Department of Oncology, Lund (Sweden); Luster, M. [University of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Oyen, W.J.G. [University Medical Center Nijmegen, Department of Nuclear Medicine, Nijmegen (Netherlands)

    2007-05-15

    Radionuclide therapy has distinct similarities to, but also profound differences from external radiotherapy. This review discusses techniques and results of previously developed dosimetry methods in thyroid carcinoma, neuro-endocrine tumours, solid tumours and lymphoma. In each case, emphasis is placed on the level of evidence and practical applicability. Although dosimetry has been of enormous value in the preclinical phase of radiopharmaceutical development, its clinical use to optimise administered activity on an individual patient basis has been less evident. In phase I and II trials, dosimetry may be considered an inherent part of therapy to establish the maximum tolerated dose and dose-response relationship. To prove that dosimetry-based radionuclide therapy is of additional benefit over fixed dosing or dosing per kilogram body weight, prospective randomised phase III trials with appropriate end points have to be undertaken. Data in the literature which underscore the potential of dosimetry to avoid under- and overdosing and to standardise radionuclide therapy methods internationally are very scarce. In each section, particular developments and insights into these therapies are related to opportunities for dosimetry. The recent developments in PET and PET/CT imaging, including micro-devices for animal research, and molecular medicine provide major challenges for innovative therapy and dosimetry techniques. Furthermore, the increasing scientific interest in the radiobiological features specific to radionuclide therapy will advance our ability to administer this treatment modality optimally. (orig.)

  2. Modeling corium jet breakup in water pool and application to ex-vessel fuel–coolant interaction analyses

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Kwang-Hyun, E-mail: khbang@hhu.ac.kr; Kumar, Rohit; Kim, Hyoung-Tak

    2014-09-15

    Highlights: • Kelvin–Helmholtz Instability on melt–steam–water interfaces was solved numerically. • Corium jet breakup model was developed for FCI codes based on the KHI solutions. • Ex-vessel steam explosions in reactor cavity were calculated using TRACER-II code. - Abstract: In light water reactor core melt accidents, the molten fuel can be brought into contact with coolant water in the course of the melt relocation in-vessel and ex-vessel as well as in an accident mitigation action of water addition. For the last several decades, the potential risk of energetic molten fuel coolant interactions (FCIs, steam explosions) has drawn substantial attention in the safety analysis of reactor severe accidents. In this paper, an improved melt jet breakup model is presented and analyses of an energetic fuel–coolant interaction in a PWR cavity (1) partially filled (4 m deep) and (2) completely filled (7 m deep) with water are presented. The TRACER-II code was used in the analyses. For jet breakup model, the full dispersion equation of Kelvin–Helmholtz instability for the melt jet–vapor film–water was solved numerically and the solutions were correlated for use in the TRACER-II code. The new jet breakup model was benchmarked using FARO L28 test data. In reactor calculations the mixing calculations showed that the average melt drop size was much smaller in 4 m deep pool with 3 m free-fall than in 7 m deep pool. The explosion calculations showed that the peak pressure at the center of mixture was ∼90 MPa in 4 m deep pool, ∼25 MPa in 7 m deep pool. It also showed that the maximum impulse at the cavity wall was found at the lower wall in both cases and it was 50 kPa s in 4 m deep pool and 150 kPa s in 7 m deep pool.

  3. Importance of the effective atomic number (Z{sub eff}) of TL materials for radiation dosimetry in clinical applications; Importancia del numero atomico efectivo (Z{sub eff}) de materiales TL para dosimetria de la radiacion en aplicaciones clinicas

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P.R. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: pgm@nuclear.inin.mx

    2008-07-01

    The electric power generation, it has been one of the radiation applications of bigger weight, mainly in developed countries. Another sector of more impact is without a doubt that of the medicine. However, for a sure operation with radiations, those international organisms of radiological safety, exist every time more precise detection systems. The thermoluminescent dosimetry is one of the more reliable methods for this purpose, for that several groups of investigators from different parts of the world, they have guided its investigations in the development of new TL materials. However, to avoid underestimate or overestimation of the measured dose with the use of these materials, it should take into account it effective atomic number (Z{sub eff}) it is well known that some TL materials considered as equivalent to the tissue, presents smaller TL intensity when being irradiated with low energy photons, while the TL material known as not equivalent to the tissue, they present the supra sensitivity effect for this radiation type. Nowadays, the estimate of the Z{sub eff} has not been clear, in this work the Z{sub eff} is determined by means of the traditional methods and an own method is presented for its determination. The results of the TL signal of different materials, when being irradiated with photons of effective energy between 24 keV and 1.25 MeV and their relationship with their calculated Z{sub eff} are also presented. (Author)

  4. Automated Vessel Segmentation Using Infinite Perimeter Active Contour Model with Hybrid Region Information with Application to Retinal Images.

    Science.gov (United States)

    Zhao, Yitian; Rada, Lavdie; Chen, Ke; Harding, Simon P; Zheng, Yalin

    2015-09-01

    Automated detection of blood vessel structures is becoming of crucial interest for better management of vascular disease. In this paper, we propose a new infinite active contour model that uses hybrid region information of the image to approach this problem. More specifically, an infinite perimeter regularizer, provided by using L(2) Lebesgue measure of the γ -neighborhood of boundaries, allows for better detection of small oscillatory (branching) structures than the traditional models based on the length of a feature's boundaries (i.e., H(1) Hausdorff measure). Moreover, for better general segmentation performance, the proposed model takes the advantage of using different types of region information, such as the combination of intensity information and local phase based enhancement map. The local phase based enhancement map is used for its superiority in preserving vessel edges while the given image intensity information will guarantee a correct feature's segmentation. We evaluate the performance of the proposed model by applying it to three public retinal image datasets (two datasets of color fundus photography and one fluorescein angiography dataset). The proposed model outperforms its competitors when compared with other widely used unsupervised and supervised methods. For example, the sensitivity (0.742), specificity (0.982) and accuracy (0.954) achieved on the DRIVE dataset are very close to those of the second observer's annotations.

  5. SU-F-T-578: Characterization of Vidar DosimetryPro Advantage RED Scanner with Application to SBRT and SRS QA

    Energy Technology Data Exchange (ETDEWEB)

    Dumas, M; Wen, N [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: To use Gafchromic EBT3 film to quantify key dosimetric characteristics of the Vidar DosimetryPro Advantage RED film scanner for use in SBRT/SRS QA, by analyzing scanner uniformity and dose sensitivity. Method: Gafchromic EBT3 film was used in this study. Films were irradiated using 6MV FFF and 10MV FFF beams from a Varian Edge linear accelerator, with setup of 100cm SAD at depth 5 cm. Nine doses were delivered per film, with calibration dose ranges of 1–10 Gy and 3–24 Gy for 6MV FFF, and 3–27 Gy for 10MV FFF. Films were scanned with the long side of the film parallel to the detector array. Dose calibration curves were fitted to a 3rd degree polynomial. The derivative of a calibration curve was taken to determine the scanner’s sensitivity per dose delivered (OD/Gy). Scanner non-uniformity was calculated in 2 dimensions by taking the mean of standard deviation in each row and column. Absolute dose SRS/SBRT Gamma analyses were performed with passing criteria of 3% and 1mm DTA. For comparison, Gamma analyses were also performed using an Epson Expression 10000 XL. Results: Uniformity for the Vidar scanner was 0.37% +/− 0.03% in the perpendicular to scan direction and 0.67% +/− 0.05% in the parallel to scan direction, with an overall uniformity of 0.52% +/− 0.03%. Epson red channel uniformity was 0.85% +/− 0.05% and 0.88% +/− 0.08% for the green channel. The Vidar average dose sensitivity from 1–10 Gy was 0.112 OD/Gy and 0.061 OD/Gy for 3–24 Gy. SBRT/SRS Gamma pass rates were 97.8 +/− 1.4 for Vidar and 97.5 +/− 1.4 for Epson. Conclusion: The Vidar scanner has 41% less non-uniformity compared to Epson XL10000 green channel. The dose sensitivity is 2–3 time greater for the Vidar scanner compared to the Epson in the SRS/SBRT dose range of 5–24 Gy.

  6. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications

    Science.gov (United States)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-01

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus Hp(3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  7. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications.

    Science.gov (United States)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-21

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus H p (3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  8. Dosimetric evaluation of the Fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry; Avaliacao dosimetrica da solucao Fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimetria de eletrons e neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Mangueira, Thyago Fressatti [Instituto de Pesquisas Energeticas e Nucleares (GMR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Metrologia das Radiacoes

    2011-07-01

    The main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a thermal neutron field were also evaluated for application in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometry. For clinical fields the intra and inter-batch reproducibility of FXG solution are better than 1.4% and 5.1%, respectively. The optical response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the electron energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h. The behavior of the dose-response curve does not change the obtained absorbance values relative to the non-irradiated dosimeter response during the studied period. The dose-response curve to industrial electron beam presented an exponential decreasing behavior. The optical response to thermal neutrons beam presented a linear behavior for the studied dose range. According to the obtained results to the different radiation fields studied it was not observed changes in the wavelength of the typical bands of the absorption spectrum radiation induced. Additional tests were performed with FXG solution to verify the viability and application of FXG dosimetry on intracavitary brachytherapy using digital photographic imaging. The excellent performance of the FXG dosimeter indicates that this dosimeter may be applied to tri-dimensional dose evaluation in radiotherapy treatments using electrons and neutron beams. (author)

  9. Monte Carol-Based Dosimetry of Beta-Emitters for Intravascular Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, C.K.

    2002-06-25

    Monte Carlo simulations for radiation dosimetry and the experimental verifications of the simulations have been developed for the treatment geometry of intravascular brachytherapy, a form of radionuclide therapy for occluded coronary disease (restenosis). Monte Carlo code, MCNP4C, has been used to calculate the radiation dose from the encapsulated array of B-emitting seeds (Sr/Y-source train). Solid water phantoms have been fabricated to measure the dose on the radiochromic films that were exposed to the beta source train for both linear and curved coronary vessel geometries. While the dose difference for the 5-degree curved vessel at the prescription point of f+2.0 mm is within the 10% guideline set by the AAPM, however, the difference increased dramatically to 16.85% for the 10-degree case which requires additional adjustment for the acceptable dosimetry planning. The experimental dose measurements agree well with the simulation results

  10. Towards an Ultrasonic Guided Wave Procedure for Health Monitoring of Composite Vessels: Application to Hydrogen-Powered Aircraft

    Directory of Open Access Journals (Sweden)

    Slah Yaacoubi

    2017-09-01

    Full Text Available This paper presents an overview and description of the approach to be used to investigate the behavior and the defect sensitivity of various ultrasonic guided wave (UGW modes propagating specifically in composite cylindrical vessels in the framework of the safety of hydrogen energy transportation such as hydrogen-powered aircrafts. These structures which consist of thick and multi-layer composites are envisioned for housing hydrogen gas at high pressures. Due to safety concerns associated with a weakened structure, structural health monitoring techniques are needed. A procedure for optimizing damage detection in these structural types is presented. It is shown that a finite element method can help identify useful experimental parameters including frequency range, excitation type, and receiver placement.

  11. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  12. The personal dosimetry in Mexico; La dosimetria personal en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A. [Proxtronics/ Asesoria Integral en Dosimetria Termoluminiscente S.A. de C.V., Canal de Miramontes 2030-14, Col. Educacion, 04400 Mexico D.F. (Mexico)]. e-mail: aidtsa@avantel.net

    2006-07-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  13. Optically stimulated luminescence techniques in retrospective dosimetry

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Murray, A.S.

    2001-01-01

    Optically stimulated luminescence signals from natural quartz and feldspar are now used routinely in dating geological and archaeological materials. More recently they have also been employed in accident dosimetry, i.e. the retrospective assessment of doses received as a result of a nuclear...... accident. Since 1990 the exploration of this wide variety of applications has driven an intensive investigation and development programme at Riso, in measurement facilities and techniques. This paper reviews some of the outcomes of this programme, including (i) optimisation of stimulation and emission...... windows, and detection sensitivity, (ii) experience with various stimulation light sources, including filtered incandescent lamps (420-550 nm) and high intensity light emitting diodes (470 nm) and laser diodes (830-850 nm). We also discuss recently developed high-precision single-aliquot measurement...

  14. Gel dosimetry for conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G. [Department of Physics of the University and INFN, Milan (Italy)]. e-mail: grazia.gambarini@mi.infn.it

    2005-07-01

    With the continuum development of conformal radio therapies, aimed at delivering high dose to tumor tissue and low dose to the healthy tissue around, the necessities has appeared of suitable improvement of dosimetry techniques giving the possibility of obtaining dose images to be compared with diagnostic images. Also if wide software has been developed for calculating dose distributions in the fields of various radiotherapy units, experimental verifications are necessary, in particular in the case of complex geometries in conformal radiotherapy. Gel dosimetry is a promising method for imaging the absorbed dose in tissue-equivalent phantoms, with the possibility of 3D reconstruction of the spatial dose distribution, with milli metric resolution. Optical imaging of gel dosimeters, based on visible light absorbance analysis, has shown to be a reliable technique for achieving dose distributions. (Author)

  15. NOTE FROM THE DOSIMETRY SERVICE

    CERN Multimedia

    2002-01-01

    During March, the Dosimetry Service will be opened from 8h30 to 12h in the morning and closed every afternoon.   We have established that many people, who are provided regularly with a personal dosimeter (film badge), have changed their activity and do not need it anymore, because they do not, or only exceptionally, enter controlled areas. If you are one of these persons, please contact the Personal Dosimeter Service (tel: 72155). There is a simplified procedure for obtaining a dosimeter if you have an immediate need for short-term visits in controlled areas. A reduction of the number of persons on the regular distribution list of dosimeters would decrease our and the distributors workload. It would also contribute to significant savings in the dosimetry, and thus CERN, budget. We thank you in advance for your understanding and for your collaboration.

  16. Dosimetry on the radiological risks prevention in radiotherapy; La dosimetria en la prevencion de riesgos radiologicos en radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Fornet R, O. M.; Perez G, F., E-mail: nuclear2@citmahlg.holguin.inf.cu [Delegacion Territorial del CITMA, Peralta 16 esq. P. Feria, Rpto. Peralta, 80400 Holguin (Cuba)

    2014-08-15

    Dosimetry in its various forms plays a determining role on the radiological risks prevention in radiotherapy. To prove this in this paper is shown an analysis based on the risk matrix method, how the dosimetry can influence in each stages of a radiotherapy service; installation and acceptance, operation, maintenance and calibration. For each one of these stages the role that can play is analyzed as either the initiating event of a radiological accident or limiting barrier of these events of the dosimetric processes used for the individual dosimetry, the area monitoring, fixed or portable, for radiation beam dosimetry and of the patients for a radiotherapy service with cobalt-therapy equipment. The result of the study shows that the application of a prospective approach in the role evaluation of dosimetry in the prevention and mitigation of the consequences of a radiological accident in radiotherapy is crucial and should be subject to permanent evaluation at each development stage of these services. (author)

  17. MISTI Shielding and Dosimetry Experiment Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Reliable on-orbit dosimetry is necessary for understanding effects of space radiation environments on spacecraft microelectronics performance and comparison of...

  18. Dosimetric evaluation of the Fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry; Avaliacao dosimetrica da solucao Fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimentria de eletrons e neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Mangueira, Thyago Fressatti

    2009-07-01

    In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams. (author)

  19. High sensitive radiation detector for radiology dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M.; Malano, F. [Instituto de Fisica Enrique Gaviola, Oficina 102 FaMAF - UNC, Av. Luis Medina Allende, Ciudad Universitaria, 5000 Cordoba (Argentina); Molina, W.; Vedelago, J., E-mail: valente@famac.unc.edu.ar [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  20. 46 CFR 380.11 - Designation of American Great Lakes Vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Designation of American Great Lakes Vessels. 380.11... Application for Designation of Vessels as American Great Lakes Vessels § 380.11 Designation of American Great Lakes Vessels. The Secretary shall designate a vessel as an American Great Lakes vessel if— (a) The...

  1. Dosimetry of {beta} extensive sources; Dosimetria de fuentes {beta} extensas

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E.L.; Lallena R, A.M. [Departamento de Fisica Moderna, Universidad de Granada, E-18071 Granada (Spain)

    2002-07-01

    In this work, we have been studied, making use of the Penelope Monte Carlo simulation code, the dosimetry of {beta} extensive sources in situations of spherical geometry including interfaces. These configurations are of interest in the treatment of the called cranealfaringyomes of some synovia leisure of knee and other problems of interest in medical physics. Therefore, its application can be extended toward problems of another areas with similar geometric situation and beta sources. (Author)

  2. EPR Dosimetry - Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Regulla, D.F. [GSF - National Research Centre for Environment and Health, Institute of Radiation Protection, 85764 Neuherberg (Germany)

    1999-07-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  3. Dosimetry studies in Zaborie village

    Energy Technology Data Exchange (ETDEWEB)

    Takada, J. E-mail: jtakada@ipc.hiroshima-u.ac.jp; Hoshi, M.; Endo, S.; Stepanenko, V.F.; Kondrashov, A.E.; Petin, D.; Skvortsov, V.; Ivannikov, A.; Tikounov, D.; Gavrilin, Y.; Snykov, V.P

    2000-05-15

    Dosimetry studies in Zaborie, a territory in Russia highly contaminated by the Chernobyl accident, were carried out in July, 1997. Studies on dosimetry for people are important not only for epidemiology but also for recovery of local social activity. The local contamination of the soil was measured to be 1.5-6.3 MBq/m{sup 2} of Cs-137 with 0.7-4 {mu}Sv/h of dose rate. A case study for a villager presently 40 years old indicates estimations of 72 and 269 mSv as the expected internal and external doses during 50 years starting in 1997 based on data of a whole-body measurement of Cs-137 and environmental dose rates. Mean values of accumulated external and internal doses for the period from the year 1986 till 1996 are also estimated to be 130 mSv and 16 mSv for Zaborie. The estimation of the 1986-1996 accumulated dose on the basis of large scale ESR teeth enamel dosimetry provides for this village, the value of 180 mSv. For a short term visitor from Japan to this area, external and internal dose are estimated to be 0.13 mSv/9d (during visit in 1997) and 0.024 mSv/50y (during 50 years starting from 1997), respectively.

  4. Comparison of applicability of current transition temperature shift models to SA533B-1 reactor pressure vessel steel of Korean nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji Hyun; Lee, Bong Sang [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-08-15

    The precise prediction of radiation embrittlement of aged reactor pressure vessels (RPVs) is a prerequisite for the long-term operation of nuclear power plants beyond their original design life. The expiration of the operation licenses for Korean reactors the RPVs of which are made from SA533B-1 plates and welds is imminent. Korean regulatory rules have adopted the US Nuclear Regulatory Commission's transition temperature shift (TTS) models to the prediction of the embrittlement of Korean reactor pressure vessels. The applicability of the TTS model to predict the embrittlement of Korean RPVs made of SA533B-1 plates and welds was investigated in this study. It was concluded that the TTS model of 10 CFR 50.61a matched the trends of the radiation embrittlement in the SA533B-1 plates and welds better than did that of Regulatory Guide (RG) 1.99 Rev. 2. This is attributed to the fact that the prediction performance of 10 CFR 50.61a was enhanced by considering the difference in radiation embrittlement sensitivity among the different types of RPV materials.

  5. A Feasibility Study of Fricke Dosimetry as an Absorbed Dose to Water Standard for 192Ir HDR Sources

    Science.gov (United States)

    deAlmeida, Carlos Eduardo; Ochoa, Ricardo; de Lima, Marilene Coelho; David, Mariano Gazineu; Pires, Evandro Jesus; Peixoto, José Guilherme; Salata, Camila; Bernal, Mario Antônio

    2014-01-01

    High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future. PMID:25521914

  6. International cooperation within the IRCP using the example of internal dosimetry; Internationale Zusammenarbeit innerhalb der ICRP am Beispiel der internen Dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Nosske, Dietmar

    2017-10-01

    IRCP is working since decades in the field of internal dosimetry and defines limiting values for occupational exposed persons, individuals in the population and patients in the diagnostic nuclear medicine that are worldwide included in the national and international radiation protection regulations. The effort to be as realistic as possible is producing continuously more complex models. This fact is delaying the respective values and aggravates the application of the models. In order to facilitate the application other institutions like EURADOS (European radiation dosimetry group) generate appropriate guidelines. Cooperation is taking place between ISRP and the respective institutions.

  7. Vision-Based Corrosion Detection Assisted by a Micro-Aerial Vehicle in a Vessel Inspection Application

    Directory of Open Access Journals (Sweden)

    Alberto Ortiz

    2016-12-01

    Full Text Available Vessel maintenance requires periodic visual inspection of the hull in order to detect typical defective situations of steel structures such as, among others, coating breakdown and corrosion. These inspections are typically performed by well-trained surveyors at great cost because of the need for providing access means (e.g., scaffolding and/or cherry pickers that allow the inspector to be at arm’s reach from the structure under inspection. This paper describes a defect detection approach comprising a micro-aerial vehicle which is used to collect images from the surfaces under inspection, particularly focusing on remote areas where the surveyor has no visual access, and a coating breakdown/corrosion detector based on a three-layer feed-forward artificial neural network. As it is discussed in the paper, the success of the inspection process depends not only on the defect detection software but also on a number of assistance functions provided by the control architecture of the aerial platform, whose aim is to improve picture quality. Both aspects of the work are described along the different sections of the paper, as well as the classification performance attained.

  8. Latest developments in silica fibre luminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, D. A.; Abdul S, S. F.; Jafari, S. M.; Alanazi, A. [University of Surrey, Department of Physics, GU2 7XH Guildford, Surrey (United Kingdom); Amouzad M, G. [University of Malaya, Faculty of Engineering, Department of Electrical Engineering, Integrated Lightwave Research Group, 50603 Kuala Lumpur (Malaysia); Addul R, H. A.; Mizanur R, A. K. M.; Zubair, H. T.; Begum, M.; Yusoff, Z.; Omar, N. Y. M. [Multimedia University, Faculty of Engineering, 2010 Cyberjaya, Selangor (Malaysia); Maah, M. J. [University of Malaya, Department of Chemistry, 50603 Kuala Lumpur (Malaysia); Collin, S. [National Physical Laboratory, Hampton Road, Teddington, TW11 OLW Middlesex (United Kingdom); Mat-Sharif, K. A.; Muhd-Yassin, S. Z.; Zulkifli, M. I., E-mail: d.a.bradley@surrey.ac.uk [Telekom Malaysia Research and Development Sdn Bhd., 63000 Cyberjaya, Selangor (Malaysia)

    2015-10-15

    Full text: Using tailor made sub-mm diameter doped-silica fibres, we are carrying out luminescence dosimetry studies for a range of situations, including thermoluminescence (Tl)investigations on a liquid alpha source formed of {sup 223}RaCl (the basis of the Bayer Health care product Xofigo), the Tl response to a 62 MeV proton source and Tl response to irradiation from an {sup 241}Am-Be neutron source. In regard to the former, in accord with the intrinsic high linear energy transfer (Let) and short path length (<100 um) of the α-particles in calcified tissue, the product is in part intended as a bone-seeking radionuclide for treatment of metastatic cancer, offering high specificity and efficacy. The Tl yield of Ge-doped SiO{sub 2} fibres has been investigated including for photonic crystal fibre un collapsed, flat fibres and single mode fibres, these systems offering many advantages over conventional passive dosimetry types. In particular, one can mention comparable and even superior sensitivity, an effective atomic number Z{sub eff} of the silica dosimetric material close to that of bone, and the glassy nature of the fibres offering the additional advantage of being able to place such dosimeters directly into liquid environments. Finally we review the use of our tailor made fibres for on-line radioluminescence measurements of radiotherapy beams. The outcome from these various lines of research is expected to inform development of doped fiber radiation dosimeters of versatile utility, ranging from clinical applications through to industrial studies and environmental evaluations. (Author)

  9. Pulse-resolved radiotherapy dosimetry using fiber-coupled organic scintillators

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg

    This PhD project pertains to the development and adaptation of a dosimetry system that can be used to verify the delivery of radiation in modern radiotherapy modalities involving small radiation fields and dynamic radiation delivery. The dosimetry system is based on fibre-coupled organic scintill......This PhD project pertains to the development and adaptation of a dosimetry system that can be used to verify the delivery of radiation in modern radiotherapy modalities involving small radiation fields and dynamic radiation delivery. The dosimetry system is based on fibre-coupled organic...... millimeter, which is small enough to resolve the small radiation fields encountered in modern radiotherapy. The fast readout of the dosimeter enables measurements on the same time scale as the pulsed radiation delivery from the medical linear accelerators used for treatment. The dosimetry system, comprising...... for both standard and small fields. This thesis concludes that the new pulse-resolved dosimetry system holds great potential for modern radiotherapy applications, such as stereotactic radiotherapy and intensity-modulated radiotherapy....

  10. High-dose dosimetry using natural silicate minerals

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Mendes, Leticia, E-mail: isatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina, E-mail: lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear; Barbosa, Renata F., E-mail: profcelta@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil). Departamento de Ciencias do Mar

    2015-07-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  11. The use of Monte Carlo codes in internal dosimetry; Utilisation des codes de Monte Carlo en dosimetrie interne

    Energy Technology Data Exchange (ETDEWEB)

    Ricard, M.; Coulot, J. [Institut Gustave-Roussy, Service de Physique, 94 - Villejuif (France)

    2003-07-01

    Internal dosimetry concerns the radiation sources inside human body. It contributes to determine the energy depositions in a living organism following the accidental or medical irradiation. In the case of an accidental irradiation, the aim is to evaluate the risk estimation; in the case of a medical use the dosimetry data are used in a radiation protection purpose. In any case, it is necessary to have references methods in order to know the dose absorbed bound to the radioactive product incorporation. Three levels have to be considered: the organ level in radiation protection, the cellular and tissue levels for application in radiotherapy. The analytical methods become rapidly difficult to use so the Monte Carlo methods give now a correct statistical precision. The advantages of this way of doing are developed in this article. (N.C.)

  12. ESR dosimetry using eggshells and tooth enamel for accidental dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Toshihide; Yamanaka, Chihiro; Ikeya, Motoji [Department of Earth and Space Science, Faculty of Science, Osaka Univ., Toyonaka, Osaka (Japan)

    1997-07-01

    The CO{sub 2}{sup -} signal of eggshells showed a good dose linearity and was appropriate in the wide dose range from 1 to 10 kGy, while ESR signal of CO{sub 2}{sup -} in sea and fresh water shells were saturated at a dose od below 10 kGy. The minimum detectable dose and G-value of CO{sub 2}{sup -} in eggshells were estimated 0.3 Gy and 0.28, respectively. The lifetime of CO{sub 2}{sup -} in eggshells could not be determined exactly because of overlapping organic signals, however it is still sufficiently long for practical use as ESR dosimeter materials. Various bird`s or reptile`s eggshells would be available as natural retrospective ESR dosimeter materials after nuclear accidents. Eggshells will be useful for the food irradiation dosimetry in the dose range of about a few kGy. Tooth enamel is one of the most useful dosimeter materials in public at a accident because of its high sensitivity. ESR dosimetry will replace TLD in near future if the cost of an ESR reader is further reduced . (author)

  13. The Future of Medical Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Robert D., E-mail: robert_adams@med.unc.edu

    2015-07-01

    The world of health care delivery is becoming increasingly complex. The purpose of this manuscript is to analyze current metrics and analytically predict future practices and principles of medical dosimetry. The results indicate five potential areas precipitating change factors: a) evolutionary and revolutionary thinking processes, b) social factors, c) economic factors, d) political factors, and e) technological factors. Outcomes indicate that significant changes will occur in the job structure and content of being a practicing medical dosimetrist. Discussion indicates potential variables that can occur within each process and change factor and how the predicted outcomes can deviate from normative values. Finally, based on predicted outcomes, future opportunities for medical dosimetrists are given.

  14. Relocation of the Dosimetry Service

    CERN Multimedia

    2007-01-01

    The Dosimetry Service is moving from Building 24 to Building 55 and will therefore be closed on Friday, 30 March. From Monday, 2 April onwards you will find us in Building 55/1-001. Please note that we cannot exclude problems with Internet connections on that day and are therefore unable to guarantee normal service. The Service's opening hours and telephone number will not change as a result of the move: Open from 8.30 - 12.00. Closed in the afternoons. Tel. 7 2155

  15. Applications of the Monte Carlo simulation in dosimetry and medical physics problems; Aplicaciones de la simulacion Monte Carlo en dosimetria y problemas de fisica medica

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E. L., E-mail: leticia.rojas@inin.gob.m [ININ, Gerencia de Ciencias Ambientales, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-07-01

    At the present time the computers use to solve important problems extends to all the areas. These areas can be of social, economic, of engineering, of basic and applied science, etc. With and appropriate handling of computation programs and information can be carried out calculations and simulations of real models, to study them and to solve theoretical or application problems. The processes that contain random variables are susceptible of being approached with the Monte Carlo method. This is a numeric method that, thanks to the improvements in the processors of the computers, it can apply in many tasks more than what was made in the principles of their practical application (at the beginning of the decade of 1950). In this work the application of the Monte Carlo method will be approached in the simulation of the radiation interaction with the matter, to investigate dosimetric aspects of some problems that exist in the medical physics area. Also, contain an introduction about some historical data and some general concepts related with the Monte Carlo simulation are revised. (Author)

  16. A mathematical model for cost of maritime transport. Application to competitiveness of nuclear vessels; Modele mathematique du cout de transport maritime application a la competitivite du navire nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Dorval, C. [Commissariat a l' Energie Atomique, 75 - Paris (France)

    1966-05-01

    In studying the competitiveness of a nuclear merchant vessel, economic assessments in terms of figures were discarded in favor of a simplified model, which gives a clearer idea of the mechanism of the comparison between alternative vessels and the particular influence of each parameter. An expression is formulated for the unit cost per ton carried over a given distance as a function of the variables (speed and deadweight tonnage) and is used to determine the optima for conventional and nuclear vessels. To represent the freight market involved in the optimization studies, and thus in the competitiveness computation, two cases are taken into account: the tonnage to be carried annually is limited, and the tonnage to be carried annually is not limited. In both cases the optima are calculated and compared for a conventional and a nuclear vessel. Competitiveness curves are plotted as a function of the ratios of nuclear and conventional fuel costs and nuclear and conventional marginal power costs. These curves express the limiting values of the above two ratios for which the transport costs of the nuclear and conventional vessels are equal. The competitiveness curves vary considerably according to the hypothesis adopted for the freight market and the limit of tonnage carried annually. (author) [French] Pour etudier la competitivite du navire marchand nucleaire, plutot que de nous livrer a des evaluations economiques chiffrees, discutables dans l'etat actuel des etudes, nous utilisons un modele simplifie permettant de mieux saisir le mecanisme de la comparaison des navires et l'influence particuliere de chaque parametre. Nous etablissons une expression du cout unitaire de la tonne transportee sur un parcours donne en fonction des variables vitesse et port en lourd. Et nous l'utilisons pour determiner les optima des navires classiques et nucleaires. Pour representer le marche du fret qui intervient dans les etudes d'optimisation, et donc dans la

  17. BIOASSAY VESSEL FAILURE ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    Vormelker, P

    2008-09-22

    Two high-pressure bioassay vessels failed at the Savannah River Site during a microwave heating process for biosample testing. Improper installation of the thermal shield in the first failure caused the vessel to burst during microwave heating. The second vessel failure is attributed to overpressurization during a test run. Vessel failure appeared to initiate in the mold parting line, the thinnest cross-section of the octagonal vessel. No material flaws were found in the vessel that would impair its structural performance. Content weight should be minimized to reduce operating temperature and pressure. Outer vessel life is dependent on actual temperature exposure. Since thermal aging of the vessels can be detrimental to their performance, it was recommended that the vessels be used for a limited number of cycles to be determined by additional testing.

  18. Temperature dependence of the Al2O3:C response in medical luminescence dosimetry

    DEFF Research Database (Denmark)

    Edmund, Jens Morgenthaler; Andersen, Claus Erik

    2007-01-01

    Over the last years, attention has been given to applications of Al2O3:C in space and medical dosimetry. One such application is in vivo dose verification in radiotherapy of cancer patients and here we investigate the temperature effects on the radioluminescence (RL) and optically stimulated...

  19. Dispensing-based bioprinting of mechanically-functional hybrid scaffolds with vessel-like channels for tissue engineering applications - A brief review.

    Science.gov (United States)

    Naghieh, Saman; Sarker, Md; Izadifar, Mohammad; Chen, Xiongbiao

    2018-02-01

    Over the past decades, significant progress has been achieved in the field of tissue engineering (TE) to restore/repair damaged tissues or organs and, in this regard, scaffolds made from biomaterials have played a critical role. Notably, recent advances in biomaterials and three-dimensional (3D) printing have enabled the manipulation of two or more biomaterials of distinct, yet complementary, mechanical and/or biological properties to form so-called hybrid scaffolds mimicking native tissues. Among various biomaterials, hydrogels synthesized to incorporate living cells and/or biological molecules have dominated due to their hydrated tissue-like environment. Moreover, dispensing-based bioprinting has evolved to the point that it can now be used to create hybrid scaffolds with complex structures. However, the complexities associated with multi-material bioprinting and synthesis of hydrogels used for hybrid scaffolds pose many challenges for their fabrication. This paper presents a brief review of dispensing-based bioprinting of hybrid scaffolds for TE applications. The focus is on the design and fabrication of hybrid scaffolds, including imaging techniques, potential biomaterials, physical architecture, mechanical properties, cell viability, and the importance of vessel-like channels. The key issues and challenges for dispensing-based bioprinting of hybrid scaffolds are also identified and discussed along with recommendations for future research directions. Addressing these issues will significantly enhance the design and fabrication of hybrid scaffolds to and pave the way for translating them into clinical applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Dosimetry in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing {sup 32} P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  1. Reactor lifetime under control: the contribution of the VENUS neutron dosimetry programme

    Energy Technology Data Exchange (ETDEWEB)

    Ait Abderrahim, H.; Minsart, G.; Dhondt, P. [SCK-CEN, Boeretang 200, B-2400 Mol (Belgium)

    1998-07-01

    Lifetime management of PWR reactors is an important stake concerning safety and competitiveness of these electricity production systems. The embrittlement of the pressure vessel is due to neutron exposure is the main limiting phenomenon of the PWR lifetime. Therefore, an accurate assessment of the pressure vessel fast fluency contributes deeply to a better management of the reactor lifetime. The Light Water Reactor Pressure Vessel Surveillance Dosimetry Improvement Program (LWR-PV-SDIP) was established in 1977 and sponsored by the US NRC. Its objectives were: improve, maintain and standardize neutron dosimetry, damage correlation and associated reactor analysis procedures used for predicting integrated effects of neutron exposure on LWR-PV. The VENUS PWR-Engineering Mock-up Experiment is part of the Belgian PWR- Pressure Vessel Surveillance Programme sponsored by the Belgian utilities. It contributed also, as one of the benchmark fields to the LWR-PV-SDIP, the VENUS mock-ups simulate the reflector geometry and the core boundary shape of a generic 3-loop PWR reactor. In this paper we will report on the three configurations considered in this programme namely: VENUS-1 simulating a PWR fresh core loading, VENUS-2 simulating a low-Ieakage core loading, and VENUS-3 simulating the PLSA (Partial Length Shielded Assembly) concept. Thanks to this programme, the PWR PV fast fluency can be assessed with an uncertainty ranging between 15 and 20%. (author)

  2. Magnetic Fluid Hyperthermia for Bladder Cancer: A Preclinical Dosimetry Study

    Science.gov (United States)

    Oliveira, Tiago R.; Stauffer, Paul R.; Lee, Chen-Ting; Landon, Chelsea D.; Etienne, Wiguins; Ashcraft, Kathleen A.; McNerny, Katie L.; Mashal, Alireza; Nouls, John; Maccarini, Paolo F.; Beyer, Wayne F.; Inman, Brant; Dewhirst, Mark W.

    2014-01-01

    Purpose This paper describes a preclinical investigation of the feasibility of thermotherapy treatment of bladder cancer with Magnetic Fluid Hyperthermia (MFH), performed by analyzing the thermal dosimetry of nanoparticle heating in a rat bladder model. Materials and Methods The bladders of twenty-five female rats were instilled with magnetite-based nanoparticles, and hyperthermia was induced using a novel small animal magnetic field applicator (Actium Biosystems, Boulder, CO). We aimed to increase the bladder lumen temperature to 42°C in <10 min and maintain that temperature for 60 min. Temperatures were measured within the bladder lumen and throughout the rat with seven fiberoptic probes (OpSens Technologies, Quebec, Canada). An MRI analysis was used to confirm the effectiveness of the catheterization method to deliver and maintain various nanoparticle volumes within the bladder. Thermal dosimetry measurements recorded the temperature rise of rat tissues for a variety of nanoparticle exposure conditions. Results Thermal dosimetry data demonstrated our ability to raise and control the temperature of rat bladder lumen ≥1°C/min to a steady-state of 42°C with minimal heating of surrounding normal tissues. MRI scans confirmed the homogenous nanoparticle distribution throughout the bladder. Conclusion These data demonstrate that our MFH system with magnetite-based nanoparticles provide well-localized heating of rat bladder lumen with effective control of temperature in the bladder and minimal heating of surrounding tissues. PMID:24050253

  3. A small-scale anatomical dosimetry model of the liver

    Science.gov (United States)

    Stenvall, Anna; Larsson, Erik; Strand, Sven-Erik; Jönsson, Bo-Anders

    2014-07-01

    Radionuclide therapy is a growing and promising approach for treating and prolonging the lives of patients with cancer. For therapies where high activities are administered, the liver can become a dose-limiting organ; often with a complex, non-uniform activity distribution and resulting non-uniform absorbed-dose distribution. This paper therefore presents a small-scale dosimetry model for various source-target combinations within the human liver microarchitecture. Using Monte Carlo simulations, Medical Internal Radiation Dose formalism-compatible specific absorbed fractions were calculated for monoenergetic electrons; photons; alpha particles; and 125I, 90Y, 211At, 99mTc, 111In, 177Lu, 131I and 18F. S values and the ratio of local absorbed dose to the whole-organ average absorbed dose was calculated, enabling a transformation of dosimetry calculations from macro- to microstructure level. For heterogeneous activity distributions, for example uptake in Kupffer cells of radionuclides emitting low-energy electrons (125I) or high-LET alpha particles (211At) the target absorbed dose for the part of the space of Disse, closest to the source, was more than eight- and five-fold the average absorbed dose to the liver, respectively. With the increasing interest in radionuclide therapy of the liver, the presented model is an applicable tool for small-scale liver dosimetry in order to study detailed dose-effect relationships in the liver.

  4. Introduction to radiological physics and radiation dosimetry

    CERN Document Server

    Attix, Frank Herbert

    2004-01-01

    A straightforward presentation of the broad concepts underlying radiological physics and radiation dosimetry for the graduate-level student. Covers photon and neutron attenuation, radiation and charged particle equilibrium, interactions of photons and charged particles with matter, radiotherapy dosimetry, as well as photographic, calorimetric, chemical, and thermoluminescence dosimetry. Includes many new derivations, such as Kramers X-ray spectrum, as well as topics that have not been thoroughly analyzed in other texts, such as broad-beam attenuation and geometrics, and the reciprocity theorem

  5. Guam Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Guam. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  6. Florida Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Florida. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  7. Vessel Arrival Info - Legacy

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Vessel Arrival Info is a spreadsheet that gets filled out during the initial stage of the debriefing process by the debriefer. It contains vessel name, trip...

  8. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  9. On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy

    Science.gov (United States)

    Chen, Zhe; Agostinelli, Alfred; Nath, Ravinder

    1998-03-01

    The dosimetry of total-skin electron therapy (TSET) usually requires ionization chamber measurements in a large electron beam (up to ). Exposing the chamber's electric cable, its connector and part of the extension cable to the large electron beam will introduce unwanted electronic signals that may lead to inaccurate dosimetry results. While the best strategy to minimize the cable-induced electronic signal is to shield the cables and its connector from the primary electrons, as has been recommended by the AAPM Task Group Report 23 on TSET, cables without additional shielding are often used in TSET dosimetry measurements for logistic reasons, for example when an automatic scanning dosimetry is used. This paper systematically investigates the consequences and the acceptability of using an unshielded cable in ionization chamber dosimetry in a large TSET electron beam. In this paper, we separate cable-induced signals into two types. The type-I signal includes all charges induced which do not change sign upon switching the chamber polarity, and type II includes all those that do. The type-I signal is easily cancelled by the polarity averaging method. The type-II cable-induced signal is independent of the depth of the chamber in a phantom and its magnitude relative to the true signal determines the acceptability of a cable for use under unshielded conditions. Three different cables were evaluated in two different TSET beams in this investigation. For dosimetry near the depth of maximum buildup, the cable-induced dosimetry error was found to be less than 0.2% when the two-polarity averaging technique was applied. At greater depths, the relative dosimetry error was found to increase at a rate approximately equal to the inverse of the electron depth dose. Since the application of the two-polarity averaging technique requires a constant-irradiation condition, it was demonstrated that an additional error of up to 4% could be introduced if the unshielded cable's spatial

  10. Development a high-resolution radiation dosimetry system based on Fricke solutions

    Energy Technology Data Exchange (ETDEWEB)

    Vedelago, J. [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina); Mattea, F. [Universidad Nacional de Cordoba, Facultad de Ciencias Quimicas, Departamento de Quimica Organica, Ciudad Universitaria, 5000 Cordoba (Argentina); Valente, M., E-mail: josevedelago@gmail.com [Instituto de Fisica E. Gaviola, Oficina 102 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  11. Statistical analysis of personal dosimetry of exposed workers; Analisis estadistico de la dosimetria personal de trabajadores expuestos

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Munoz, F. J.; Alejo Luque, L.; Mas Munoz, I.; Serrada Hierro, A.

    2013-07-01

    The dosimetry centers accredited by the Nuclear Safety Council (CSN) normally report overcoming legal limits, or some fraction thereof, but do not provide comparative dosimetric criteria indicating if assigned to a given dose is large TPE or small relative to that of their peers. In order to help to resolve the difficulties mentioned ds, it has developed an application that statistically processes the dosimetric data provided by the National Dosimetry Center. (Author)

  12. A new method for dosimetry with films radiochromic; Un nuevo metodo para la dosimetria con peliculas radiocromica

    Energy Technology Data Exchange (ETDEWEB)

    Mendez Carot, I.

    2013-07-01

    in this paper a new method is presented and the results of the comparison between the calibration is summarized based on a planning reference and calibration obtained from the irradiated fragments measure different dose levels multichannel compare dosimetry based on the weighted average dosimetry described by Micke et al.(present in the FilmQAPro software) and, finally, show different results obtained with the method proposed in several applications clinics. (Author)

  13. Development and application of a volume penalization immersed boundary method for the computation of blood flow and shear stresses in cerebral vessels and aneurysms

    NARCIS (Netherlands)

    Mikhal, Julia Olegivna; Geurts, Bernardus J.

    2013-01-01

    A volume-penalizing immersed boundary method is presented for the simulation of laminar incompressible flow inside geometrically complex blood vessels in the human brain. We concentrate on cerebral aneurysms and compute flow in curved brain vessels with and without spherical aneurysm cavities

  14. Dosimetry and radiobiology at the new RA-3 reactor boron neutron capture therapy (BNCT) facility: Application to the treatment of experimental oral cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, E. [Research and Production Reactors, National Atomic Energy Commission, Ezeiza Atomic Center (Argentina); Department of Radiobiology, National Atomic Energy Commission, Constituyentes Atomic Center (Argentina)], E-mail: epozzi@cnea.gov.ar; Nigg, D.W. [Idaho National Laboratory, Idaho Falls (United States); Miller, M.; Thorp, S.I. [Instrumentation and Control Department, National Atomic Energy Commission, Ezeiza Atomic Center (Argentina); Heber, E.M. [Department of Radiobiology, National Atomic Energy Commission, Constituyentes Atomic Center (Argentina); Zarza, L.; Estryk, G. [Research and Production Reactors, National Atomic Energy Commission, Ezeiza Atomic Center (Argentina); Monti Hughes, A.; Molinari, A.J.; Garabalino, M. [Department of Radiobiology, National Atomic Energy Commission, Constituyentes Atomic Center (Argentina); Itoiz, M.E. [Department of Radiobiology, National Atomic Energy Commission, Constituyentes Atomic Center (Argentina); Department of Oral Pathology, Faculty of Dentistry, University of Buenos Aires (Argentina); Aromando, R.F. [Department of Oral Pathology, Faculty of Dentistry, University of Buenos Aires (Argentina); Quintana, J. [Research and Production Reactors, National Atomic Energy Commission, Ezeiza Atomic Center (Argentina); Trivillin, V.A.; Schwint, A.E. [Department of Radiobiology, National Atomic Energy Commission, Constituyentes Atomic Center (Argentina)

    2009-07-15

    The National Atomic Energy Commission of Argentina (CNEA) constructed a novel thermal neutron source for use in boron neutron capture therapy (BNCT) applications at the RA-3 research reactor facility located in Buenos Aires. The aim of the present study was to perform a dosimetric characterization of the facility and undertake radiobiological studies of BNCT in an experimental model of oral cancer in the hamster cheek pouch. The free-field thermal flux was 7.1x10{sup 9} n cm{sup -2} s{sup -1} and the fast neutron flux was 2.5x10{sup 6} n cm{sup -2} s{sup -1}, indicating a very well-thermalized neutron field with negligible fast neutron dose. For radiobiological studies it was necessary to shield the body of the hamster from the neutron flux while exposing the everted cheek pouch bearing the tumors. To that end we developed a lithium (enriched to 95% in {sup 6}Li) carbonate enclosure. Groups of tumor-bearing hamsters were submitted to BPA-BNCT, GB-10-BNCT, (GB-10+BPA)-BNCT or beam only treatments. Normal (non-cancerized) hamsters were treated similarly to evaluate normal tissue radiotoxicity. The total physical dose delivered to tumor with the BNCT treatments ranged from 6 to 8.5 Gy. Tumor control at 30 days ranged from 73% to 85%, with no normal tissue radiotoxicity. Significant but reversible mucositis in precancerous tissue surrounding tumors was associated to BPA-BNCT. The therapeutic success of different BNCT protocols in treating experimental oral cancer at this novel facility was unequivocally demonstrated.

  15. An investigation of the thermoluminescence of Ge-doped SiO{sub 2} optical fibres for application in interface radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Abdul Rahman, A.T., E-mail: a.t.abdulrahman@surrey.ac.uk [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, GU2 7XH Guildford (United Kingdom); School of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA Malaysia (UiTM), Campus of Negeri Sembilan, 72000 Kuala Pilah (Malaysia); Hugtenburg, R.P. [Department of Medical Physics and Clinical Engineering, Abertawe Bro Morgannwg UHB and School of Medicine, Swansea University, Swansea SA2 8PP (United Kingdom); Abdul Sani, Siti Fairus; Alalawi, A.I.M. [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, GU2 7XH Guildford (United Kingdom); Issa, Fatma [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, GU2 7XH Guildford (United Kingdom); Department of Radiotherapy, Tripoli Medical Centre (TMC), Tripoli (Libya); Thomas, R. [Radiation Dosimetry Team, National Physical Laboratory, Teddington (United Kingdom); Barry, M.A. [Department of Medical Physics, The Royal Surrey County Hospital (RSCH) NHS Trust, Guildford, GU2 7XX Surrey (United Kingdom); Nisbet, A. [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, GU2 7XH Guildford (United Kingdom); Department of Medical Physics, The Royal Surrey County Hospital (RSCH) NHS Trust, Guildford, GU2 7XX Surrey (United Kingdom); Bradley, D.A. [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, GU2 7XH Guildford (United Kingdom); Department of Radiological Sciences, King Saud University, P.O. Box 10219, Riyadh 11432 (Saudi Arabia)

    2012-07-15

    We investigate the ability of high spatial resolution ({approx} 120 {mu}m) Ge-doped SiO{sub 2} TL dosimeters to measure photoelectron dose enhancement resulting from the use of a moderate to high-Z target (an iodinated contrast media) irradiated by 90 kVp X-rays. We imagine its application in a novel radiation synovectomy technique, modelled by a phantom containing a reservoir of I{sub 2} molecules at the interface of which the doped silica dosimeters are located. Measurements outside of the iodine photoelectron range are provided for using a stepped-design that allows insertion of the fibres within the phantom. Monte Carlo simulation (MCNPX) is used for verification. At the phantom medium I{sub 2}-interface additional photoelectron generation is observed, {approx}60% above that in the absence of the I{sub 2}, simulations providing agreement to within 3%. Percentage depth doses measured away from the iodine contrast medium reservoir are bounded by published PDDs at 80 kVp and 100 kVp. - Highlights: Black-Right-Pointing-Triangle Studies of dosimetric characteristic of commercially available doped silica optical fibres. Black-Right-Pointing-Triangle Investigation of the potential of the dosimeter in dose enhancement measurement. Black-Right-Pointing-Triangle Use of photoelectron dose enhancement as might be applied in radiation synovectomy. Black-Right-Pointing-Triangle Measurement of the percentage depth dose recorded by Ge-doped silica optical fibres. Black-Right-Pointing-Triangle The Monte Carlo simulation provides comparison against measured data.

  16. The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults—application to CT dosimetry

    Science.gov (United States)

    Geyer, Amy M.; O'Reilly, Shannon; Lee, Choonsik; Long, Daniel J.; Bolch, Wesley E.

    2014-09-01

    Substantial increases in pediatric and adult obesity in the US have prompted a major revision to the current UF/NCI (University of Florida/National Cancer Institute) family of hybrid computational phantoms to more accurately reflect current trends in larger body morphometry. A decision was made to construct the new library in a gridded fashion by height/weight without further reference to age-dependent weight/height percentiles as these become quickly outdated. At each height/weight combination, circumferential parameters were defined and used for phantom construction. All morphometric data for the new library were taken from the CDC NHANES survey data over the time period 1999-2006, the most recent reported survey period. A subset of the phantom library was then used in a CT organ dose sensitivity study to examine the degree to which body morphometry influences the magnitude of organ doses for patients that are underweight to morbidly obese in body size. Using primary and secondary morphometric parameters, grids containing 100 adult male height/weight bins, 93 adult female height/weight bins, 85 pediatric male height/weight bins and 73 pediatric female height/weight bins were constructed. These grids served as the blueprints for construction of a comprehensive library of patient-dependent phantoms containing 351 computational phantoms. At a given phantom standing height, normalized CT organ doses were shown to linearly decrease with increasing phantom BMI for pediatric males, while curvilinear decreases in organ dose were shown with increasing phantom BMI for adult females. These results suggest that one very useful application of the phantom library would be the construction of a pre-computed dose library for CT imaging as needed for patient dose-tracking.

  17. Dosimetry and radiobiology at the new RA-3 reactor boron neutron capture therapy (BNCT) facility: application to the treatment of experimental oral cancer.

    Science.gov (United States)

    Pozzi, E; Nigg, D W; Miller, M; Thorp, S I; Heber, E M; Zarza, L; Estryk, G; Monti Hughes, A; Molinari, A J; Garabalino, M; Itoiz, M E; Aromando, R F; Quintana, J; Trivillin, V A; Schwint, A E

    2009-07-01

    The National Atomic Energy Commission of Argentina (CNEA) constructed a novel thermal neutron source for use in boron neutron capture therapy (BNCT) applications at the RA-3 research reactor facility located in Buenos Aires. The aim of the present study was to perform a dosimetric characterization of the facility and undertake radiobiological studies of BNCT in an experimental model of oral cancer in the hamster cheek pouch. The free-field thermal flux was 7.1 x 10(9) n cm(-2)s(-1) and the fast neutron flux was 2.5 x 10(6) n cm(-2)s(-1), indicating a very well-thermalized neutron field with negligible fast neutron dose. For radiobiological studies it was necessary to shield the body of the hamster from the neutron flux while exposing the everted cheek pouch bearing the tumors. To that end we developed a lithium (enriched to 95% in (6)Li) carbonate enclosure. Groups of tumor-bearing hamsters were submitted to BPA-BNCT, GB-10-BNCT, (GB-10+BPA)-BNCT or beam only treatments. Normal (non-cancerized) hamsters were treated similarly to evaluate normal tissue radiotoxicity. The total physical dose delivered to tumor with the BNCT treatments ranged from 6 to 8.5 Gy. Tumor control at 30 days ranged from 73% to 85%, with no normal tissue radiotoxicity. Significant but reversible mucositis in precancerous tissue surrounding tumors was associated to BPA-BNCT. The therapeutic success of different BNCT protocols in treating experimental oral cancer at this novel facility was unequivocally demonstrated.

  18. ALICE HMPID Radiator Vessel

    CERN Multimedia

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  19. Innovation and the future of advanced dosimetry: 2D to 5D

    Science.gov (United States)

    Oldham, Mark

    2017-05-01

    Recent years have witnessed a remarkable evolution in the techniques, capabilities and applications of 3D dosimetry. Initially the goal was simple: to innovate new techniques capable of comprehensively measuring and verifying exquisitely intricate dose distributions from a paradigm changing emerging new therapy, IMRT. Basic questions emerged: how well were treatment planning systems modelling the complex delivery, and how could treatments be verified for safe use on patients? Since that time, equally significant leaps of innovation have continued in the technology of treatment delivery. In addition, clinical practice has been transformed by the addition of on-board imaging capabilities, which tend to hypo-fractionation strategies and margin reduction. The net result is a high stakes treatment setting where the clinical morbidity of any unintended treatment deviation is exacerbated by the combination of highly conformal dose distributions given with reduced margins with fractionation regimens unfriendly to healthy tissue. Not surprisingly this scenario is replete with challenges and opportunities for new and improved dosimetry systems. In particular tremendous interest exists in comprehensive 3D dosimetry systems, and systems that can resolve the dose in moving structures (4D) and even in deforming structures (5D). Despite significant progress in the capability of multi-dimensional dosimetry systems, it is striking that true 3D dosimetry systems are today largely found in academic institutions or specialist clinics. The reasons will be explored. We will highlight innovations occurring both in treatment delivery and in advanced dosimetry methods designed to verify them, and explore current and future opportunities for advanced dosimetry tools in clinical practice and translational research.

  20. Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry

    Science.gov (United States)

    Nagaoka, Tomoaki; Watanabe, Soichi; Sakurai, Kiyoko; Kunieda, Etsuo; Watanabe, Satoshi; Taki, Masao; Yamanaka, Yukio

    2004-01-01

    With advances in computer performance, the use of high-resolution voxel models of the entire human body has become more frequent in numerical dosimetries of electromagnetic waves. Using magnetic resonance imaging, we have developed realistic high-resolution whole-body voxel models for Japanese adult males and females of average height and weight. The developed models consist of cubic voxels of 2 mm on each side; the models are segmented into 51 anatomic regions. The adult female model is the first of its kind in the world and both are the first Asian voxel models (representing average Japanese) that enable numerical evaluation of electromagnetic dosimetry at high frequencies of up to 3 GHz. In this paper, we will also describe the basic SAR characteristics of the developed models for the VHF/UHF bands, calculated using the finite-difference time-domain method.

  1. Cross sections required for FMIT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Gold, R.; McElroy, W.N.; Lippincott, E.P.; Mann, F.M.; Oberg, D.L.; Roberts, J.H.; Ruddy, F.H.

    1980-05-02

    The Fusion Materials Irradiation Test (FMIT) facility, currently under construction, is designed to produce a high flux of high energy neutrons for irradiation effects experiments on fusion reactor materials. Characterization of the flux-fluence-spectrum in this rapidly varying neutron field requires adaptation and extension of currently available dosimetry techniques. This characterization will be carried out by a combination of active, passive, and calculational dosimetry. The goal is to provide the experimenter with accurate neutron flux-fluence-spectra at all positions in the test cell. Plans have been completed for a number of experimental dosimetry stations and provision for these facilities has been incorporated into the FMIT design. Overall needs of the FMIT irradiation damage program delineate goal accuracies for dosimetry that, in turn, create new requirements for high energy neutron cross section data. Recommendations based on these needs have been derived for required cross section data and accuracies.

  2. In vivo dosimetry in brachytherapy.

    Science.gov (United States)

    Tanderup, Kari; Beddar, Sam; Andersen, Claus E; Kertzscher, Gustavo; Cygler, Joanna E

    2013-07-01

    In vivo dosimetry (IVD) has been used in brachytherapy (BT) for decades with a number of different detectors and measurement technologies. However, IVD in BT has been subject to certain difficulties and complexities, in particular due to challenges of the high-gradient BT dose distribution and the large range of dose and dose rate. Due to these challenges, the sensitivity and specificity toward error detection has been limited, and IVD has mainly been restricted to detection of gross errors. Given these factors, routine use of IVD is currently limited in many departments. Although the impact of potential errors may be detrimental since treatments are typically administered in large fractions and with high-gradient-dose-distributions, BT is usually delivered without independent verification of the treatment delivery. This Vision 20/20 paper encourages improvements within BT safety by developments of IVD into an effective method of independent treatment verification.

  3. In vivo dosimetry in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tanderup, Kari [Department of Oncology, Aarhus University Hospital, Aarhus 8000 (Denmark); Department of Clinical Medicine, Aarhus University, Aarhus 8000 (Denmark); Beddar, Sam [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Andersen, Claus E.; Kertzscher, Gustavo [Center of Nuclear Technologies, Technical University of Denmark, Roskilde 4000 (Denmark); Cygler, Joanna E. [Department of Physics, Ottawa Hospital Cancer Centre, Ottawa, Ontario K1H 8L6 (Canada)

    2013-07-15

    In vivo dosimetry (IVD) has been used in brachytherapy (BT) for decades with a number of different detectors and measurement technologies. However, IVD in BT has been subject to certain difficulties and complexities, in particular due to challenges of the high-gradient BT dose distribution and the large range of dose and dose rate. Due to these challenges, the sensitivity and specificity toward error detection has been limited, and IVD has mainly been restricted to detection of gross errors. Given these factors, routine use of IVD is currently limited in many departments. Although the impact of potential errors may be detrimental since treatments are typically administered in large fractions and with high-gradient-dose-distributions, BT is usually delivered without independent verification of the treatment delivery. This Vision 20/20 paper encourages improvements within BT safety by developments of IVD into an effective method of independent treatment verification.

  4. Development of radiation biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chul Koo; Kim, Tae Hwan; Lee, Yun Sil; Son, Young Sook; Kim, Soo Kwan; Jang, Won Suk; Le, Sun Joo; Jee, Young Heun; Jung, Woo Jung

    1999-04-01

    Up until now, only a few methods have been developed for radiation biological dosimetry such as conventional chromosome aberration and micronucleus in peripheral blood cell. However, because these methods not only can be estimated by the expert, but also have a little limitation due to need high technique and many times in the case of radiation accident, it is very difficult to evaluate the absorbed dose of victims. Therefore, we should develop effective, easy, simple and rapid biodosimetry and its guideline (triage) to be able to be treated the victims as fast as possible. We established the premature chromosome condensation assay and apoptotic fragment assay which was the significant relationship between dose and cell damages to evaluate the irradiation dose as correct and rapid as possible using lymphocytes and crypt cells, and compared with conventional chromosome aberration assay and micronuclei assay.

  5. A Review of the Application of Rate Theory to Simulate Vacancy Cluster Formation and Interstitial Defect Formation in Reactor Pressure Vessel Steel

    Directory of Open Access Journals (Sweden)

    Fallon Laliberte

    2015-10-01

    Full Text Available The beltline region of the reactor pressure vessel (RPV is subject to an extreme radiation, temperature, and pressure environment over several decades of operation; therefore it is necessary to understand the mechanisms through which radiation damage occurs and how it affects the mechanical and chemical properties of the RPV steel. Chemical rate theory is a mean field rate theory simulation model which applies chemistry to the evaluation of irradiation-induced embrittlement. It presents one method of analysis that may be coupled to other distinct methods, in order to analyze defect formation, ultimately providing useful information on strength, ductility, toughness and dimensional stability changes for effects such as embrittlement, reduction in ductility and toughness, void swelling, hardening, irradiation creep, stress corrosion cracking, etc. over time as materials are subjected to reactor operational irradiation. This paper serves as a brief review of rate theory fundamentals and presents several examples of research that exemplify the application and importance of rate theory in examining the effects of radiation damage on RPV steel.

  6. Application of Response Surface Methodology for Modeling of Postweld Heat Treatment Process in a Pressure Vessel Steel ASTM A516 Grade 70.

    Science.gov (United States)

    Peasura, Prachya

    2015-01-01

    This research studied the application of the response surface methodology (RSM) and central composite design (CCD) experiment in mathematical model and optimizes postweld heat treatment (PWHT). The material of study is a pressure vessel steel ASTM A516 grade 70 that is used for gas metal arc welding. PWHT parameters examined in this study included PWHT temperatures and time. The resulting materials were examined using CCD experiment and the RSM to determine the resulting material tensile strength test, observed with optical microscopy and scanning electron microscopy. The experimental results show that using a full quadratic model with the proposed mathematical model is YTS = -285.521 + 15.706X1 + 2.514X2 - 0.004X1(2) - 0.001X2(2) - 0.029X1X2. Tensile strength parameters of PWHT were optimized PWHT time of 5.00 hr and PWHT temperature of 645.75°C. The results show that the PWHT time is the dominant mechanism used to modify the tensile strength compared to the PWHT temperatures. This phenomenon could be explained by the fact that pearlite can contribute to higher tensile strength. Pearlite has an intensity, which results in increased material tensile strength. The research described here can be used as material data on PWHT parameters for an ASTM A516 grade 70 weld.

  7. Trends in gel dosimetry: Preliminary bibliometric overview of active growth areas, research trends and hot topics from Gore’s 1984 paper onwards

    Science.gov (United States)

    Baldock, C.

    2017-05-01

    John Gore’s seminal 1984 paper on gel dosimetry spawned a vibrant research field ranging from fundamental science through to clinical applications. A preliminary bibliometric study was undertaken of the gel dosimetry family of publications inspired by, and resulting from, Gore’s original 1984 paper to determine active growth areas, research trends and hot topics from Gore’s paper up to and including 2016. Themes and trends of the gel dosimetry research field were bibliometrically explored by way of co-occurrence term maps using the titles and abstracts text corpora from the Web of Science database for all relevant papers from 1984 to 2016. Visualisation of similarities was used by way of the VOSviewer visualisation tool to generate cluster maps of gel dosimetry knowledge domains and the associated citation impact of topics within the domains. Heat maps were then generated to assist in the understanding of active growth areas, research trends, and emerging and hot topics in gel dosimetry.

  8. Uncertainty in 3D gel dosimetry

    Science.gov (United States)

    De Deene, Yves; Jirasek, Andrew

    2015-01-01

    Three-dimensional (3D) gel dosimetry has a unique role to play in safeguarding conformal radiotherapy treatments as the technique can cover the full treatment chain and provides the radiation oncologist with the integrated dose distribution in 3D. It can also be applied to benchmark new treatment strategies such as image guided and tracking radiotherapy techniques. A major obstacle that has hindered the wider dissemination of gel dosimetry in radiotherapy centres is a lack of confidence in the reliability of the measured dose distribution. Uncertainties in 3D dosimeters are attributed to both dosimeter properties and scanning performance. In polymer gel dosimetry with MRI readout, discrepancies in dose response of large polymer gel dosimeters versus small calibration phantoms have been reported which can lead to significant inaccuracies in the dose maps. The sources of error in polymer gel dosimetry with MRI readout are well understood and it has been demonstrated that with a carefully designed scanning protocol, the overall uncertainty in absolute dose that can currently be obtained falls within 5% on an individual voxel basis, for a minimum voxel size of 5 mm3. However, several research groups have chosen to use polymer gel dosimetry in a relative manner by normalizing the dose distribution towards an internal reference dose within the gel dosimeter phantom. 3D dosimetry with optical scanning has also been mostly applied in a relative way, although in principle absolute calibration is possible. As the optical absorption in 3D dosimeters is less dependent on temperature it can be expected that the achievable accuracy is higher with optical CT. The precision in optical scanning of 3D dosimeters depends to a large extend on the performance of the detector. 3D dosimetry with X-ray CT readout is a low contrast imaging modality for polymer gel dosimetry. Sources of error in x-ray CT polymer gel dosimetry (XCT) are currently under investigation and include inherent

  9. Chemical vapour deposited diamonds for dosimetry of radiotherapeutical beams

    Energy Technology Data Exchange (ETDEWEB)

    Bucciolini, M.; Mazzocchi, S. [Firenze Univ., Firenze (Italy). Dipartimento di Fisiopatologia Clinica; INFN, Firenze (Italy); Borchi, E.; Bruzzi, M.; Pini, S.; Sciortino, S. [Firenze Univ., Firenze (Italy). Dipartimento di Energetica; INFN, Firenze (Italy); Cirrone, G.A.P.; Guttone, G.; Raffaele, L.; Sabini, M.G. [INFN, Catania (Italy). Laboratori Nazionali del Sud

    2002-07-01

    This paper deals with the application of synthetic diamond detectors to the clinical dosimetry of photon and electron beams. It has been developed in the frame of INFN CANDIDO project and MURST Cofin. Diamonds grown with CVD (Chemical Vapour Deposition) technique have been studied; some of them are commercial samples while others have been locally synthesised. Experiments have been formed using both on-line and off-line approaches. For the off-line measurements, TL (thermoluminescent) and TSC (thermally stimulated current) techniques have been used.

  10. Pulsed beam dosimetry using fiber-coupled radioluminescence detectors

    DEFF Research Database (Denmark)

    Andersen, Claus Erik

    2012-01-01

    The objective of this work was to review and discuss the potential application of fiber-coupled radioluminescence detectors for dosimetry in pulsed MV photon beams. Two types of materials were used: carbon-doped aluminium oxide (Al2O3:C) and organic plastic scintillators. Special consideration...... was given to the discrimination between radioluminescence signals from the phosphors and unwanted light induced in the optical fiber cables during irradiation (Cerenkov and fluorescence). New instrumentation for dose-per-pulse measurements with organic plastic scintillators was developed....

  11. Application of luminescence techniques in retrospective dosimetry

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Jungner, H.

    1999-01-01

    Luminescence signals measured from minerals within bricks or ceramic samples can provide information about the absorbed radiation dose. This feature has for several years been used in dating archaeological and geological samples and recently luminescence techniques have been intensively used far...... retrospective assessment of accident doses received by the population after a nuclear accident. The development of new luminescence techniques after the Chernobyl accident has considerably improved the sensitivity and precision in the evaluation of accident doses. This paper reviews the development work......, especially on optically stimulated luminescence methods for retrospective assessment of accident doses carried out at Riso National Laboratory in collaboration with the University of Helsinki as part bf a joint European Union research project. We demonstrate that doses lower than 100 mGy can be measured from...

  12. Fourth conference on radiation protection and dosimetry: Proceedings, program, and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Casson, W.H.; Thein, C.M.; Bogard, J.S. [eds.

    1994-10-01

    This Conference is the fourth in a series of conferences organized by staff members of Oak Ridge National Laboratory in an effort to improve communication in the field of radiation protection and dosimetry. Scientists, regulators, managers, professionals, technologists, and vendors from the United States and countries around the world have taken advantage of this opportunity to meet with their contemporaries and peers in order to exchange information and ideas. The program includes over 100 papers in 9 sessions, plus an additional session for works in progress. Papers are presented in external dosimetry, internal dosimetry, radiation protection programs and assessments, developments in instrumentation and materials, environmental and medical applications, and on topics related to standards, accreditation, and calibration. Individual papers are indexed separately on EDB.

  13. A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI ☆

    OpenAIRE

    Okell, Thomas W.; Chappell, Michael A.; Jezzard, Peter

    2013-01-01

    Angiographic methods can provide valuable information on vessel morphology and hemodynamics, but are often qualitative in nature, somewhat limiting their ability for comparison across arteries and subjects. In this work we present a method for quantifying absolute blood volume flow rates within large vessels using dynamic angiographic data. First, a kinetic model incorporating relative blood volume, bolus dispersion and signal attenuation is fitted to the data. A self-calibration method is al...

  14. The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes

    NARCIS (Netherlands)

    Louwe, R. J. W.; McDermott, L. N.; Sonke, J. J.; Tielenburg, R.; Wendling, M.; van Herk, M. B.; Mijnheer, B. J.

    2004-01-01

    This study was carried out to determine the stability of the response of amorphous silicon (a-Si)-flat panel imagers for dosimetry applications. Measurements of the imager's response under reference conditions were performed on a regular basis for four detectors of the same manufacturer. We found

  15. Mathematics in medicine: tumor detection, radiation dosimetry, and simulation in psychotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bellman, R.; Kashef, B.; Smith, C.P.; Ueno, S.; Vasudevan, R.

    1975-05-01

    Work done in the application of mathematics to medicine over the last 20 years is briefly reviewed. Scan-rescan processes, radiation dosimetry, and medical interviewing are discussed. The first uses dynamic programming, the second invariant imbedding, and the third simulation. (ACR)

  16. Analysis of HFIR Dosimetry Experiments Performed in Cycles 400 and 401

    Energy Technology Data Exchange (ETDEWEB)

    Remec, Igor [ORNL; Baldwin, Charles A [ORNL

    2008-09-01

    The High Flux Isotope Reactor (HFIR) has been in operation at Oak Ridge National Laboratory since 1966. To upgrade and enhance capabilities for neutron science research at the reactor, a larger HB-2 beam tube was installed in April of 2002. To assess, experimentally, the impact of this larger beam tube on radiation damage rates [i.e., displacement-per-atom (dpa) rates] used in vessel life extension studies, dosimetry experiments were performed from April to August 2004 during fuel cycles 400 and 401. This report documents the analysis of the dosimetry experiments and the determination of best-estimate dpa rates. These dpa rates are obtained by performing a least-squares adjustment of calculated neutron and gamma-ray fluxes and the measured responses of radiometric monitors and beryllium helium accumulation fluence monitors. The best-estimate dpa rates provided here will be used to update HFIR pressure vessel life extension studies, which determine the pressure/temperature limits for reactor operation and the HFIR pressure vessel's remaining life. All irradiation parameters given in this report correspond to a reactor power of 85 MW.

  17. In aqua vivo EPID dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Wendling, Markus; McDermott, Leah N.; Mans, Anton; Olaciregui-Ruiz, Igor; Pecharroman-Gallego, Raul; Sonke, Jan-Jakob; Stroom, Joep; Herk, Marcel J.; Mijnheer, Ben van [Department of Radiation Oncology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands)

    2012-01-15

    Purpose: At the Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital in vivo dosimetry using an electronic portal imaging device (EPID) has been implemented for almost all high-energy photon treatments of cancer with curative intent. Lung cancer treatments were initially excluded, because the original back-projection dose-reconstruction algorithm uses water-based scatter-correction kernels and therefore does not account for tissue inhomogeneities accurately. The aim of this study was to test a new method, in aqua vivo EPID dosimetry, for fast dose verification of lung cancer irradiations during actual patient treatment. Methods: The key feature of our method is the dose reconstruction in the patient from EPID images, obtained during the actual treatment, whereby the images have been converted to a situation as if the patient consisted entirely of water; hence, the method is termed in aqua vivo. This is done by multiplying the measured in vivo EPID image with the ratio of two digitally reconstructed transmission images for the unit-density and inhomogeneous tissue situation. For dose verification, a comparison is made with the calculated dose distribution with the inhomogeneity correction switched off. IMRT treatment verification is performed for each beam in 2D using a 2D {gamma} evaluation, while for the verification of volumetric-modulated arc therapy (VMAT) treatments in 3D a 3D {gamma} evaluation is applied using the same parameters (3%, 3 mm). The method was tested using two inhomogeneous phantoms simulating a tumor in lung and measuring its sensitivity for patient positioning errors. Subsequently five IMRT and five VMAT clinical lung cancer treatments were investigated, using both the conventional back-projection algorithm and the in aqua vivo method. The verification results of the in aqua vivo method were statistically analyzed for 751 lung cancer patients treated with IMRT and 50 lung cancer patients treated with VMAT. Results: The improvements by

  18. Luminescence dosimetry using building materials and personal objects.

    Science.gov (United States)

    Göksu, H Y; Bailiff, I K

    2006-01-01

    There is a growing public awareness of the risk of accidental radiation exposure due to ageing nuclear power installations, illegal dumping of nuclear waste and terrorist activities, and of the consequential health risks to populations in addition to social and economic disturbance extending beyond national boundaries. In the event of catastrophic incidents where no direct radiation monitoring data are available, the application of retrospective dosimetry techniques such as luminescence may be employed with materials from the immediate environment to confirm values of cumulative gamma dose to compare with or augment computational modeling calculations. Application of the method to post-Chernobyl studies has resulted in the development of new procedures using fired building materials with the capability to measure cumulative doses owing to artificial sources of gamma radiation as low as 20 mGy. Combined with Monte Carlo simulations of photon transport, values of cumulative dose in brick can be presented in a form suitable for use in dose-reconstruction efforts. Recent investigations have also shown that certain types of cementitious building material, including concrete, mortar and plaster, and personal objects in the form of telephone cards containing microchips and dental ceramics have the potential to be used for retrospective dosimetry. Examples of the most recent research concerning new materials and examples of application to sites in the Former Soviet Union are discussed.

  19. Maury Journals - German Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — German vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  20. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    CERN Document Server

    Cooper, J R

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual.

  1. Dosimetry intercomparisons in European medical device sterilization plants

    DEFF Research Database (Denmark)

    Miller, A.; Sharpe, P.H.G.

    2000-01-01

    Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy of the o......Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy...

  2. 50 CFR 300.13 - Vessel permits.

    Science.gov (United States)

    2010-10-01

    ... vessel undermined the effectiveness of international conservation and management measures, and the new... special product or service. The fee is specified with the application form. The appropriate fee must... applicant of any deficiency in the application. (f) Validity. Permits issued under this subpart are valid...

  3. Fiber optically coupled radioluminescence detectors: A short review of key strengths and weaknesses of BCF-60 and Al2O3:C scintillating-material based systems in radiotherapy dosimetry applications

    Science.gov (United States)

    Buranurak, S.; Andersen, C. E.

    2017-06-01

    Radiotherapy technologies have improved for several decades aiming to effectively destroy cancerous tissues without overdosing surrounding healthy tissues. In order to fulfil this requirement, accurate and precise dosimetry systems play an important role. Throughout the years, ionization chambers have been used as a standard detector for basic linear accelerator calibrations and reference dosimetry in hospitals. However, they are not ideal for all treatment modalities: and limitations and difficulties have been reported in case of (i) small treatment fields, (ii) strong magnetic field used in the new hybrid MRI LINAC/cobalt systems, and (iii) in vivo measurements due to safety-issues related to the high operating voltage. Fiber optically coupled luminescence detectors provide a promising supplement to ionization chambers by offering the capability of real-time in vivo dose monitoring with high time resolution. In particular, the all-optical nature of these detectors is an advantage for in vivo measurements due to the absence of high voltage supply or electrical wire that could cause harm to the patient or disturb the treatment. Basically, fiber-coupled luminescence detector systems function by radiation-induced generation of radioluminescence from a sub-mm size organic/inorganic phosphor. A thin optical fiber cable is used for guiding the radioluminescence to a photomultiplier tube or similar sensitive light detection systems. The measured light intensity is proportional to dose rate. Throughout the years, developments and research of the fiber detector systems have undergone in several groups worldwide. In this article, the in-house developed fiber detector systems based on two luminescence phosphors of (i) BCF-60 polystyrene-based organic plastic scintillator and (ii) carbon-doped aluminum oxide crystal (Al2O3:C) are reviewed with comparison to the same material-based systems reported in the literature. The potential use of these detectors for reference

  4. PRESSURE-RESISTANT VESSEL

    NARCIS (Netherlands)

    Beukers, A.; De Jong, T.

    1997-01-01

    Abstract of WO 9717570 (A1) The invention is directed to a wheel-shaped pressure-resistant vessel for gaseous, liquid or liquefied material having a substantially rigid shape, said vessel comprising a substantially continuous shell of a fiber-reinforced resin having a central opening, an inner

  5. HTGR Base Technology Program. Task 2: concrete properties in nuclear environment. A review of concrete material systems for application to prestressed concrete pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Naus, D.J.

    1981-05-01

    Prestressed concrete pressure vessels (PCPVs) are designed to serve as primary pressure containment structures. The safety of these structures depends on a correct assessment of the loadings and proper design of the vessels to accept these loadings. Proper vessel design requires a knowledge of the component (material) properties. Because concrete is one of the primary constituents of PCPVs, knowledge of its behavior is required to produce optimum PCPV designs. Concrete material systems are reviewed with respect to constituents, mix design, placing, curing, and strength evaluations, and typical concrete property data are presented. Effects of extreme loadings (elevated temperature, multiaxial, irradiation) on concrete behavior are described. Finally, specialty concrete material systems (high strength, fibrous, polymer, lightweight, refractory) are reviewed. 235 references.

  6. Fast neutron spectrometry and dosimetry; Spectrometrie et dosimetrie des neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Blaize, S.; Ailloud, J.; Mariani, J.; Millot, J.P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author)Fren. [French] Nous avons etudie la spectrometrie et la dosimetrie des neutrons rapides en utilisant les protons de recul qu'ils produisent dans une matiere hydrogenee. En spectrometrie, nous avons employe des emulsions nucleaires, en dosimetrie, du polyethylene recouvert de sulfure de zinc place devant un photomultiplicateur. (auteur)

  7. Survey of international personnel radiation dosimetry programs

    Energy Technology Data Exchange (ETDEWEB)

    Swaja, R.E.

    1985-04-01

    In September of 1983, a mail survey was conducted to determine the status of external personnel gamma and neutron radiation dosimetry programs at international agencies. A total of 130 agencies participated in this study including military, regulatory, university, hospital, laboratory, and utility facilities. Information concerning basic dosimeter types, calibration sources, calibration phantoms, corrections to dosimeter responses, evaluating agencies, dose equivalent reporting conventions, ranges of typical or expected dose equivalents, and degree of satisfaction with existing systems was obtained for the gamma and neutron personnel monitoring programs at responding agencies. Results of this survey indicate that to provide the best possible occupational radiation monitoring programs and to improve dosimetry accuracy in performance studies, facility dosimetrists, regulatory and standards agencies, and research laboratories must act within their areas of responsibility to become familiar with their radiation monitoring systems, establish common reporting guidelines and performance standards, and provide opportunities for dosimetry testing and evaluation. 14 references, 10 tables.

  8. Instrumentation for the individual dosimetry of workers

    CERN Document Server

    Thévenin, J C

    2003-01-01

    The control of the radiation dose exposure of workers and personnel exposed to ionizing radiations (nuclear industry, nuclear medicine, army, university laboratories etc..) is ensured by individual dosemeters. This dosimetry is mandatory for all workers susceptible to be exposed to more than 30% of the regulatory dose limit. dosemeters are worn on the chest and in some particular cases, on the finger (dosemeter rings) or on the wrist. Passive dosemeters allow to measure the dose a posteriori, while electronic dosemeters allow a direct reading and recording of the dose. This article presents successively: 1 - the general principles of individual dosimetry: situations of exposure, radiation detection, operational data, standardization, calibration and quality assurance, measurement uncertainties; 2 - goals and regulatory framework of individual dosimetry: regulation and recommendations, optimization, respect of dose limits, accidental situations; 3 - passive dosemeters: film, thermoluminescent, radio-photolumin...

  9. Bayesian Methods for Radiation Detection and Dosimetry

    CERN Document Server

    Groer, Peter G

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed comp...

  10. Containment vessel drain system

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  11. OSL Based Anthropomorphic Phantom and Real-Time Organ Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    David E. Hintenlang, Ph.D

    2009-02-10

    The overall objective of this project was the development of a dosimetry system that provides the direct measurement of organ does in real-time with a sensitivity that makes it an effective tool for applications in a wide variety of health physics applications. The system included the development of a real-time readout system for fiber optic coupled (FOC) dosimeters that is integrated with a state-of-art anthropomorphic phantom to provide instantaneous measures of organ doses throughout the phantom. The small size of the FOC detectors and optical fibers allow the sensitive volume of the detector to be located at organ centroids (or multiple locations distributed through the organ) within a tissue equivalent, anthropomorphic phantom without perturbing the tissue equivalent features of the phantom. The developed phantom/dosimetry system can be used in any environment where personnel may be exposed to gamma or x-ray radiations to provide the most accurate determinations of organ and effective doses possible to date.

  12. Diamond dosimetry: Outcomes of the CANDIDO and CONRAD INFN projects

    Energy Technology Data Exchange (ETDEWEB)

    Bucciolini, M. [Dipartimento di Fisiopatologia dell' Universita and INFN, Florence (Italy)]. E-mail: marta@dfc.unifi.it; Borchi, E. [Dipartimento di Energetica dell' Universita and INFN, Florence (Italy); Bruzzi, M. [Dipartimento di Energetica dell' Universita and INFN, Florence (Italy); Casati, M. [Dipartimento di Fisiopatologia dell' Universita and INFN, Florence (Italy); Cirrone, P. [Laboratori Nazionali del SUD, INFN, Catania (Italy); Cuttone, G. [Laboratori Nazionali del SUD, INFN, Catania (Italy); De Angelis, C. [Dipartimento di Tecnologie e Salute, Istituto Superiore di Sanita and INFN, Rome (Italy); Lovik, I. [Dipartimento di Fisiopatologia dell' Universita and INFN, Florence (Italy); Onori, S. [Dipartimento di Tecnologie e Salute, Istituto Superiore di Sanita and INFN, Rome (Italy); Raffaele, L. [Laboratori Nazionali del SUD, INFN, Catania (Italy); Sciortino, S. [Dipartimento di Energetica dell' Universita and INFN, Florence (Italy)

    2005-10-21

    This paper reviews the main results of the study, carried out in the framework of the Italian National Institute of Nuclear Physics (INFN, Istituto Nazionale di Fisica Nucleare) projects, namely CANDIDO and CONRAD, on natural and synthetic diamond-based dosimeters for clinical radiotherapy. Characteristics of diamond such as radiation hardness, high sensitivity, tissue equivalence, etc., make this material interesting for dosimetry applications. For some years, natural diamonds have been commercially available for on-line radiotherapy dosimetry. Nevertheless, recent developments in the 'Chemical Vapour Deposition' (CVD) technique have addressed the attention on synthetic samples that potentially could be grown at low cost and with features suitable for dosimetric use. Several samples, differently grown and with different electrical contacts, have been compared by measuring their current response during irradiation with high-energy photon, electron and proton beams. Properties of dosimetric interest such as linearity, pre-irradiation dose, dose rate dependence, stability and rise time have been investigated. The results obtained so far within the INFN collaboration demonstrate the suitability of natural diamond detectors for many radiotherapy applications and the great potential of CVD diamond-based devices even though, at present, the commercial natural diamond dosimeters have a better behaviour with respect to the synthetic samples. Further efforts have to be made mainly to improve the dynamic of response and performance stability.

  13. Diamond dosimetry: Outcomes of the CANDIDO and CONRAD INFN projects

    Science.gov (United States)

    Bucciolini, M.; Borchi, E.; Bruzzi, M.; Casati, M.; Cirrone, P.; Cuttone, G.; De Angelis, C.; Lovik, I.; Onori, S.; Raffaele, L.; Sciortino, S.

    2005-10-01

    This paper reviews the main results of the study, carried out in the framework of the Italian National Institute of Nuclear Physics (INFN, Istituto Nazionale di Fisica Nucleare) projects, namely CANDIDO and CONRAD, on natural and synthetic diamond-based dosimeters for clinical radiotherapy. Characteristics of diamond such as radiation hardness, high sensitivity, tissue equivalence, etc., make this material interesting for dosimetry applications. For some years, natural diamonds have been commercially available for on-line radiotherapy dosimetry. Nevertheless, recent developments in the "Chemical Vapour Deposition" (CVD) technique have addressed the attention on synthetic samples that potentially could be grown at low cost and with features suitable for dosimetric use. Several samples, differently grown and with different electrical contacts, have been compared by measuring their current response during irradiation with high-energy photon, electron and proton beams. Properties of dosimetric interest such as linearity, pre-irradiation dose, dose rate dependence, stability and rise time have been investigated. The results obtained so far within the INFN collaboration demonstrate the suitability of natural diamond detectors for many radiotherapy applications and the great potential of CVD diamond-based devices even though, at present, the commercial natural diamond dosimeters have a better behaviour with respect to the synthetic samples. Further efforts have to be made mainly to improve the dynamic of response and performance stability.

  14. Transient impedance changes in venous endothelial monolayers as a biological radiation dosimetry response

    Directory of Open Access Journals (Sweden)

    Erik Fossum Young

    2012-10-01

    Full Text Available In March of 2011, a magnitude 9.0 earthquake and subsequent 14 m-high tsunami caused major damage to the Fukushima Daiichi nuclear power plant in Japan.  While cancer incidence in the radiation-exposed population is a logical concern, the complex effects of radiation on the heart and cardiovascular system are also of interest.  Immediate and early vascular radiation effects could be exploited as a dosimetry modality.  To test whether non-coronary vasculature exhibited transient perturbation in barrier function, video microscopy studies and Electric Cell Substrate Impedance Sensing technology were used to probe very subtle changes in primary human vascular endothelium.  Human umbilical vein endothelial cell (HUVEC monolayers exhibit a transient, statistically significant decrease (P = 0.017 in monolayer resistance 3 h after irradiation with 5.0 Gy of g rays.  Radiation induced perturbations in HUVEC monolayer permeability are similar in magnitude and kinetics to those observed in coronary arterial endothelium.  Therefore, at least two types of vasculature respond to radiation on ECIS arrays with an early transient disruption in permeability.  The finding supports the use of early passage HUVECs for use in bioelectric dosimetry studies of vasculature and suggests that permeability of vessels could potentially serve as a biological dosimetry tool.

  15. Technical basis for internal dosimetry at Hanford

    Energy Technology Data Exchange (ETDEWEB)

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1991-07-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ({sup 58}Co, {sup 60}Co, {sup 54}Mn, and {sup 59}Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium,. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation and bioassay follow-up treatment. 78 refs., 35 figs., 115 tabs.

  16. Technical basis for internal dosimetry at Hanford

    Energy Technology Data Exchange (ETDEWEB)

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1989-04-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products (/sup 58/Co, /sup 60/Co, /sup 54/Mn, and /sup 59/Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation; and bioassay follow-up treatment. 64 refs., 42 figs., 118 tabs.

  17. Dosimetry of Low-Energy Beta Radiation

    DEFF Research Database (Denmark)

    Borg, Jette

    Useful techniques and procedures for derermination of absorbed doses from exposure in a low-energy beta radiation were studied and evaluated. The four techniques included were beta spectrometry, extrapolation chamber dosimetry, Monte Carlo (MC) calculations, and exoelectron dosimetry. As a typical...... low-energy beta radiation field a moderated spectrum from a carbon-14 source was used. The measured responce of a Si(Li) detector to photons (bremsstrahlung) showed fine agreemant with the MC calculated photon response, whereas the difference between measured and MC calculated response to electrons...

  18. SNL RML recommended dosimetry cross section compendium

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, P.J.; Kelly, J.G.; Luera, T.F. [Sandia National Labs., Albuquerque, NM (United States); VanDenburg, J. [Science and Engineering Associates, Inc., Albuquerque, NM (United States)

    1993-11-01

    A compendium of dosimetry cross sections is presented for use in the characterization of fission reactor spectrum and fluence. The contents of this cross section library are based upon the ENDF/B-VI and IRDF-90 cross section libraries and are recommended as a replacement for the DOSCROS84 multigroup library that is widely used by the dosimetry community. Documentation is provided on the rationale for the choice of the cross sections selected for inclusion in this library and on the uncertainty and variation in cross sections presented by state-of-the-art evaluations.

  19. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards......, the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  20. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  1. Monte Carlo modelling of Germanium detectors for the measurement of low energy photons in internal dosimetry: Results of an international comparison

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Ros, J.M. [CIEMAT, Av. Complutense 22, E-28040 Madrid (Spain)], E-mail: jm.gomezros@ciemat.es; Carlan, L. de [CEA DRT/LIST/DETECS/LNHB/LMD, Bat 534, F-91191 Gif sur Yvette, Cedex (France); IRSN DRPH/SDI/LEDI, BP6, F-92262, Fontenay-aux-Roses, Cedex (France); Franck, D. [IRSN DRPH/SDI/LEDI, BP6, F-92262, Fontenay-aux-Roses, Cedex (France); Gualdrini, G. [ENEA ION-IRP, Via dei Colli 16, I-40136 Bologna (Italy); Lis, M.; Lopez, M.A.; Moraleda, M. [CIEMAT, Av. Complutense 22, E-28040 Madrid (Spain); Zankl, M. [GSF - National Research Center for Environment and Health, D-85764 Neuherberg (Germany); Badal, A. [Institut de Tecniques Energetiques, UPC, Diagonal 647, 08028 Barcelona (Spain); Capello, K. [Human Monitoring Laboratory (Canada); Cowan, P. [Serco Assurance, Bld. A32, Winfrith Tech. Centre Winfrith, Dorchester, Dorset DT2 8DH (United Kingdom); Ferrari, P. [ENEA ION-IRP, Via dei Colli 16, I-40136 Bologna (Italy); Heide, B. [Forschungszentrum Karlsruhe, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Henniger, J. [Technical University of Dresden, 01062 Dresden (Germany); Hooley, V. [Serco Assurance, Bld. A32, Winfrith Tech. Centre Winfrith, Dorchester, Dorset DT2 8DH (United Kingdom); Hunt, J. [IRD, Av. Salvador Allende, s/n, Recreio, Rio de Janeiro (Brazil); Kinase, S. [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Kramer, G.H. [Human Monitoring Laboratory (Canada); Loehnert, D. [Technical University of Dresden, 01062 Dresden (Germany); Lucas, S. [LARN Laboratory, University of Namur, Rue de Bruxelles 61, B-5000 Namur (Belgium)] (and others)

    2008-02-15

    This communication summarizes the results concerning the Monte Carlo (MC) modelling of Germanium detectors for the measurement of low energy photons arising from the 'International comparison on MC modelling for in vivo measurement of Americium in a knee phantom' organized within the EU Coordination Action CONRAD (Coordinated Network for Radiation Dosimetry) as a joint initiative of EURADOS working groups 6 (computational dosimetry) and 7 (internal dosimetry). MC simulations proved to be an applicable way to obtain the calibration factor that needs to be used for in vivo measurements.

  2. A reusable OSL-film for 2D radiotherapy dosimetry.

    Science.gov (United States)

    Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt

    2017-10-19

    Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff ). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film's reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after 'beam on' or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities  ⩽2.6%, a linear dose response (0-32 Gy), a linear signal decay (0.5% min -1 ) over the 20 min measured, and limited angular dependence  ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film's measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([-1.6%, 2.1%] versus [-2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after irradiation

  3. A reusable OSL-film for 2D radiotherapy dosimetry

    Science.gov (United States)

    Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt

    2017-11-01

    Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film’s reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after ‘beam on’ or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities  ⩽2.6%, a linear dose response (0–32 Gy), a linear signal decay (0.5% min‑1) over the 20 min measured, and limited angular dependence  ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film’s measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([‑1.6%, 2.1%] versus [‑2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after

  4. THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013): INTERNAL DOSIMETRY RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Vostrotin, V.; Birchall, Alan; Zhdanov, Alexey; Puncher, Mathew L.; Efimov, Alexander; Napier, Bruce A.; Sokolova, Alexandra; Miller, Scott C.; Suslova, K. G.

    2017-10-31

    The distribution of calculated internal doses was determined for 8043 Mayak Production Associate (Mayak PA) workers according to the epidemiological cohorts and groups of raw data used as well as the type of industrial compounds of inhaled aerosols. Statistical characteristics of point estimates of accumulated doses to 17 different tissues and organs and the uncertainty ranges were calculated. Under the MWDS-2013 dosimetry system, the mean accumulated lung dose was 185585 mGy, with a median value of 31 mGy and a maximum of 8980 mGy maximum. The ranges of relative standard uncertainty were: from 40 to 2200% for accumulated lung dose, from 25-90% to 2600-3000% for accumulated dose to different regions of respiratory tract, from 13-18% to 2300-2500% for systemic organs and tissues. The Mayak PA workers accumulated internal plutonium lung dose is shown to be close to lognormal. The accumulated internal plutonium dose to systemic organs was close to a log-triangle. The dependency of uncertainty of accumulated absorbed lung and liver doses on the dose estimates itself is also shown. The accumulated absorbed doses to lung, alveolar-interstitial region, liver, bone surface cells and red bone marrow, calculated both with MWDS-2013 and MWDS-2008 have been compared. In general, the accumulated lung doses increased by a factor of 1.8 in median value, while the accumulated doses to systemic organs decreased by factor of 1.3-1.4 in median value. For the cases with identical initial data, accumulated lung doses increased by a factor of 2.1 in median value, while accumulated doses to systemic organs decreased by 8-13% in median value. For the cases with both identical initial data and all of plutonium activity in urine measurements above the decision threshold, accumulated lung doses increased by a factor of 2.8 in median value, while accumulated doses to systemic organs increased by 6-12% in median value.

  5. Linearization of dose-response curve of the radiochromic film dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Devic, Slobodan; Tomic, Nada; Aldelaijan, Saad; DeBlois, Francois; Seuntjens, Jan; Chan, Maria F.; Lewis, Dave [Medical Physics Unit, McGill University, Montreal, Quebec H3G 1A4 (Canada) and Department of Radiation Oncology, SMBD Jewish General Hospital, McGill University, Montreal, Quebec H3T 1E2 (Canada); Executive Administration for Radiation Protection and Safety Medical Devices Sector, Saudi Food and Drug Authority, Riyadh, Kingdom of Saudi Arabia 13312 (Saudi Arabia); Medical Physics Unit, McGill University, Montreal, Quebec H3G 1A4 (Canada) and Department of Radiation Oncology, SMBD Jewish General Hospital, McGill University, Montreal, Quebec H3T 1E2 (Canada); Medical Physics Unit, McGill University, Montreal, Quebec H3G 1A4 (Canada); Department of Medical Physics, Memorial Sloan-Kettering Cancer Center Basking Ridge, New Jersey 07920 (United States); Ashland Inc., Wayne, New Jersey 07470 (United States)

    2012-08-15

    Purpose: Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. Methods: Functional form [{zeta}= (-1){center_dot}netOD{sup (2/3)}/ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to test the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC Trade-Mark-Sign film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. Results: Obtained R{sup 2} values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC Trade-Mark-Sign EBT3 film model are well within {+-}2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also

  6. Linearization of dose-response curve of the radiochromic film dosimetry system.

    Science.gov (United States)

    Devic, Slobodan; Tomic, Nada; Aldelaijan, Saad; Deblois, Francois; Seuntjens, Jan; Chan, Maria F; Lewis, Dave

    2012-08-01

    Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. Functional form [ζ = (-1)[middle dot]netOD((2∕3))∕ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to test the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC™ film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. Obtained R(2) values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC™ EBT3 film model are well within ±2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also found that criteria of 3%∕3 mm for an IMRT QA plan and 3%∕2

  7. PREFACE: 7th International Conference on 3D Radiation Dosimetry (IC3DDose)

    Science.gov (United States)

    Thwaites, David; Baldock, Clive

    2013-06-01

    IC3DDose 2013, the 7th International Conference on 3D Radiation Dosimetry held in Sydney, Australia from 4-8 November 2012, grew out of the DosGel series, which began as DosGel99, the 1st International Workshop on Radiation Therapy Gel Dosimetry in Lexington, Kentucky. Since 1999 subsequent DoSGel conferences were held in Brisbane, Australia (2001), Ghent, Belgium (2004), Sherbrooke, Canada (2006) and Crete, Greece (2008). In 2010 the conference was held on Hilton Head Island, South Carolina and underwent a name-change to IC3DDose. The aim of the first workshop was to bring together individuals, both researchers and users, with an interest in 3D radiation dosimetry techniques, with a mix of presentations from basic science to clinical applications, which has remained an objective for all of the meetings. One rationale of DosGel99 was stated as supporting the increasing clinical implementation of gel dosimetry, as the technique appeared, at that time, to be leaving the laboratories of gel dosimetry enthusiasts and entering clinical practice. Clearly by labelling the first workshop as the 1st, there was a vision of a continuing series, which has been fulfilled. On the other hand, the expectation of widespread clinical use of gel dosimetry has perhaps not been what was hoped for and anticipated. Nevertheless the rapidly increasing demand for advanced high-precision 3D radiotherapy technology and techniques has continued apace. The need for practical and accurate 3D dosimetry methods for development and quality assurance has only increased. By the 6th meeting, held in South Carolina in 2010, the Conference Scientific Committee recognised the wider developments in 3D systems and methods and decided to widen the scope, whilst keeping the same span from basic science to applications. This was signalled by a change of name from 'Dosgel' to 'IC3DDose', a name that has continued to this latest conference. The conference objectives were: to enhance the quality and accuracy of

  8. Development in neutron dosimetry: automatic traces reading system and albedo OSL dosimetry; Developpement en dosimetrie neutron: systeme automatique de lecture de traces et dosimetrie albedo OSL

    Energy Technology Data Exchange (ETDEWEB)

    Million, M.; Perks, C.A.; Faugoin, S.; Archambault, V. [LCIE Landauer, 92 - Fontenay aux Roses (France)

    2009-07-01

    To answer to a regulatory evolution and technical constraints, the Landauer group introduced on the make an automatic reading system of neutron traces and an albedo dosemeter based on the O.S.L. in light dosemeters (O.S.L. for optically stimulated luminescence). In this article are described the last developments in matter of neutron dosimetry. (N.C.)

  9. Advances in reference and transfer dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Desrosiers, M.F. [Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States)

    1999-07-01

    All prerequisites are now in place to create a fundamentally and radically different type of calibration service for the radiation processing industry. Advancements in dosimetry and information technology can be combined to provide industry with on-line calibrations, on demand at a low cost. The remote calibration service will serve as a basis for other areas of metrology. (Author)

  10. EPR-dosimetry of ionizing radiation

    Science.gov (United States)

    Popova, Mariia; Vakhnin, Dmitrii; Tyshchenko, Igor

    2017-09-01

    This article discusses the problems that arise during the radiation sterilization of medical products. It is propose the solution based on alanine EPR-dosimetry. The parameters of spectrometer and methods of absorbed dose calculation are given. In addition, the problems that arise during heavy particles irradiation are investigated.

  11. Operating parameters of CVD diamond detectors for radiation dosimetry

    Science.gov (United States)

    Betzel, G. T.; Lansley, S. P.; Baluti, F.; Reinisch, L.; Meyer, J.

    2010-02-01

    A prototype clinical radiation detector based on commercially available single crystal diamond film made via chemical vapor deposition was investigated to determine optimal operating parameters for clinical dosimetry. This study examined how changes in applied electric field affected dosimetric performance, and determined a preferred operating voltage within the limits of clinical dosimetry equipment. Dosimetric analysis included leakage current, response dynamics such as rise and fall times, sensitivity, polarity and dependence on dose and dose rate. The results of this study indicate a preference for using a setting of 62.5 V due to its minimal rise time of 2 s, including a faster time to equilibrium, yet sufficient sensitivity of 37 nC Gy -1, which was nearly independent of polarity. At this voltage, a wider range of dose may therefore be recorded with charge collecting instruments than at higher voltages. Additionally, no clear trend was found over the range of voltages tested when evaluating dose dependence ( R2=1 for 0.78-7.8 Gy) and dose rate dependence using Fowler fitting parameter Δ (0.95≤ Δ≤1.01). Leakage currents were negligible (rise times of ≥7 s may limit the use of this detector. Following the optimization of operating parameters, clinical studies are ongoing to evaluate the use of this detector for small field and IMRT applications.

  12. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  13. 2011 Passenger Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  14. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  15. 2013 Passenger Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  16. 2013 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  17. 2013 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  18. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  19. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  20. Maury Journals - US Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — U.S. vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  1. 2011 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  2. 2011 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  3. 2013 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  4. Coastal Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels that have been issued a Federal permit for the Gulf of Mexico reef fish,...

  5. Film dosimetry in conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Danciu, C.; Proimos, B.S. [Patras Univ. (Greece). Dept. of Medical Physics

    1995-12-01

    Dosimetry, through a film sandwiched in a transverse cross-section of a solid phantom, is a method of choice in Conformal Radiotherapy because: (a) the blackness (density) of the film at each point offers a measure of the total dose received at that point, and (b) the film is easily calibrated by exposing a film strip in the same cross-section, through a stationary field. The film must therefore have the following properties: (a) it must be slow, in order not to be overexposed, even at a therapeutic dose of 200 cGy, and (b) the response of the film (density versus dose curve) must be independent of the photon energy spectrum. A few slow films were compared. It was found that the Kodak X-Omat V for therapy verification was the best choice. To investigate whether the film response was independent of the photon energy, response curves for six depths, starting from the depth of maximum dose to the depth of 25 cm, in solid phantom were derived. The vertical beam was perpendicular to the anterior surface of the phantom, which was at the distance of 100 cm from the source and the field was 15x15 cm at that distance. This procedure was repeated for photon beams emitted by a Cobalt-60 unit, two 6 MV and 15 MV Linear Accelerators, as well as a 45 MV Betatron. For each of those four different beams the film response was the same for all six depths. The results, as shown in the diagrams, are very satisfactory. The response curve under a geometry similar to that actually applied, when the film is irradiated in a transverse cross-section of the phantom, was derived. The horizontal beam was almost parallel (angle of 85) to the plane of the film. The same was repeated with the central ray parallel to the film (angle 90) and at a distance of 1.5 cm from the horizontal film. The field size was again 15x15 at the lateral entrance surface of the beam. The response curves remained the same, as when the beam was perpendicular to the films.

  6. Femtosecond laser pulse filamentation characterized by polymer gel dosimetry and Fricke dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Meesat, Ridthee; Allard, Jean-Francois; Houde, Daniel; Tremblay, Luc; Khalil, Abdelouahed; Jay-Gerin, Jean-Paul; Lepage, Martin, E-mail: Martin.Lepage@USherbrooke.c [Departement de medecine nucleaire et de radiobiologie, Faculte de medecine et des sciences de la sante, Universite de Sherbrooke, Sherbrooke (Quebec) J1H 5N4 (Canada)

    2010-11-01

    A femtosecond laser pulse that can generate water radiolysis species was studied in view of its potential medical and biological applications. Intense ultra-short laser pulses can propagate in liquid water, leading to self-focusing and filamentation. Briefly, electrons produced by either multiphoton or tunnel ionization are further accelerated by the electric field of the pulse in an inverse Bremsstrahlung effect. If the electrons acquire enough kinetic energy, they will give rise to a second generation of electrons by impact ionization of other molecules in an avalanche-like process. The geometry and trajectory of femtosecond filaments were captured within a polymer gel dosimeter and imaged by magnetic resonance imaging (MRI) at high resolution. The results revealed that changing pulse duration modifies the penetration of the filament track in the medium. In addition, we used Fricke dosimetry to measure the absorbed dose and dose rate of the femtosecond laser pulse filamentation. A very high dose rate of 5.3 x 10{sup 12} Gy/s was calculated in filaments having a diameter of {approx}600 {mu}m.

  7. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  8. Collapsible Cryogenic Storage Vessel Project

    Science.gov (United States)

    Fleming, David C.

    2002-01-01

    Collapsible cryogenic storage vessels may be useful for future space exploration missions by providing long-term storage capability using a lightweight system that can be compactly packaged for launch. Previous development efforts have identified an 'inflatable' concept as most promising. In the inflatable tank concept, the cryogen is contained within a flexible pressure wall comprised of a flexible bladder to contain the cryogen and a fabric reinforcement layer for structural strength. A flexible, high-performance insulation jacket surrounds the vessel. The weight of the tank and the cryogen is supported by rigid support structures. This design concept is developed through physical testing of a scaled pressure wall, and through development of tests for a flexible Layered Composite Insulation (LCI) insulation jacket. A demonstration pressure wall is fabricated using Spectra fabric for reinforcement, and burst tested under noncryogenic conditions. An insulation test specimens is prepared to demonstrate the effectiveness of the insulation when subject to folding effects, and to examine the effect of compression of the insulation under compressive loading to simulate the pressure effect in a nonrigid insulation blanket under the action atmospheric pressure, such as would be seen in application on the surface of Mars. Although pressure testing did not meet the design goals, the concept shows promise for the design. The testing program provides direction for future development of the collapsible cryogenic vessel concept.

  9. 46 CFR 50.05-15 - Vessels subject to regulations in this subchapter.

    Science.gov (United States)

    2010-10-01

    ...-15 Section 50.05-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Application § 50.05-15 Vessels subject to regulations in this subchapter. (a) Passenger vessels, tank vessels, cargo and miscellaneous vessels, nautical schoolships, mobile offshore...

  10. EXPERIMENTAL STUDY OF CRITICAL HEAT FLUX WITH ALUMINA-WATER NANOFLUIDS IN DOWNWARD-FACING CHANNELS FOR IN-VESSEL RETENTION APPLICATIONS

    Directory of Open Access Journals (Sweden)

    G. DEWITT

    2013-06-01

    Full Text Available The Critical Heat Flux (CHF of water with dispersed alumina nanoparticles was measured for the geometry and flow conditions relevant to the In-Vessel Retention (IVR situation which can occur during core melting sequences in certain advanced Light Water Reactors (LWRs. CHF measurements were conducted in a flow boiling loop featuring a test section designed to be thermal-hydraulically similar to the vessel/insulation gap in the Westinghouse AP1000 plant. The effects of orientation angle, pressure, mass flux, fluid type, boiling time, surface material, and surface state were investigated. Results for water-based nanofluids with alumina nanoparticles (0.001% by volume on stainless steel surface indicate an average 70% CHF enhancement with a range of 17% to 108% depending on the specific flow conditions expected for IVR. Experiments also indicate that only about thirty minutes of boiling time (which drives nanoparticle deposition are needed to obtain substantial CHF enhancement with nanofluids.

  11. Photochemical Tissue Bonding for Military Medical Applications Practical Low Cost Low Damage Blood Vessel Repair: Albumin Stent Bonded With 19xx nm Laser

    Science.gov (United States)

    2011-02-24

    endotracheal anesthesia using 1-4% isoflurane inhalant administered via endotracheal tube. Intra- operatively, Bupivicaine will be used as a local...to dilate the artery. Heparin (5,000 u, IV) will be given before clamping the vessels and to be repeated every 90 minutes until the procedure is...by water and therefore cannot cause retinal injury . Moreover, the hazard zone of the device extends only tens of centimeters from the end of the

  12. Selecting passive dosimetry technologies for measuring the external dose of terrestrial wildlife.

    Science.gov (United States)

    Aramrun, Phakphum; Beresford, Nicholas A; Wood, Michael D

    2018-02-01

    Dosimeters attached to wild animals can be used to validate regulatory assessment approaches and models for estimating radiation exposure of wild animals. Such measurements are also necessary to ensure that robust dose-effect relationships can be developed from the results of field research programmes. This paper presents the first comprehensive evaluation of the different dosimetry technologies available for specifically measuring the external exposure of wildlife. Guidance is provided on the selection of appropriate passive dosimetry approaches for directly measuring external exposure of terrestrial wildlife under field conditions. The characteristics and performance of four available dosimetry technologies (thermoluminescent dosimeter (TLD), optically stimulated luminescent dosimeter (OSLD), radiophotoluminescent dosimeter (RPLD) and direct ion storage, (DIS)) are reviewed. Dosimeter properties, detection limit and dose range, study organisms and the intended application are variables that need to be considered when selecting a suitable dosimetry technology. Evaluated against these criteria, it is suggested that LiF based and Al2O3:C TLDs, OSLD and RPLD could all be used to estimate doses to wildlife. However, only LiF based TLDs have been used to directly measure wildlife doses in field studies to date. DIS is only suitable for comparatively large species (e.g. medium to large mammals), but has the advantage that temporal variation in dose can be recorded. In all cases, dosimeter calibration is required to ensure that the dose measurements reported can be interpreted appropriately for the organisms of interest. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. VIDA: a voxel-based dosimetry method for targeted radionuclide therapy using Geant4.

    Science.gov (United States)

    Kost, Susan D; Dewaraja, Yuni K; Abramson, Richard G; Stabin, Michael G

    2015-02-01

    We have developed the Voxel-Based Internal Dosimetry Application (VIDA) to provide patient-specific dosimetry in targeted radionuclide therapy performing Monte Carlo simulations of radiation transport with the Geant4 toolkit. The code generates voxel-level dose rate maps using anatomical and physiological data taken from individual patients. Voxel level dose rate curves are then fit and integrated to yield a spatial map of radiation absorbed dose. In this article, we present validation studies using established dosimetry results, including self-dose factors (DFs) from the OLINDA/EXM program for uniform activity in unit density spheres and organ self- and cross-organ DFs in the Radiation Dose Assessment Resource (RADAR) reference adult phantom. The comparison with reference data demonstrated agreement within 5% for self-DFs to spheres and reference phantom source organs for four common radionuclides used in targeted therapy ((131)I, (90)Y, (111)In, (177)Lu). Agreement within 9% was achieved for cross-organ DFs. We also present dose estimates to normal tissues and tumors from studies of two non-Hodgkin Lymphoma patients treated by (131)I radioimmunotherapy, with comparison to results generated independently with another dosimetry code. A relative difference of 12% or less was found between methods for mean absorbed tumor doses accounting for tumor regression.

  14. Nuclear accident dosimetry: Los Alamos measurements at the seventeenth nuclear accident dosimetry intercomparison study at the Oak Ridge National Lab. , DOSAR Facility, August 1980

    Energy Technology Data Exchange (ETDEWEB)

    Vasilik, D.G.; Martin, R.W.

    1981-04-01

    Teams from various US and foreign organizations participated in the Seventeenth Nuclear Accident Dosimetry Study held at the Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research (DOSAR) facility August 11 to 15, 1980. Criticality dosimeters were simultaneously exposed to pulses of mixed neutron and gamma radiation from the Health Physics Research Reactor (HPRR). This report summarizes the experimental work conducted by the Los Alamos team. In-air and phantom measurements were conducted by the Los Alamos team using area and personnel dosimeters. Combined blood sodium and sulfur fluence measurements of absorbed dose were also made. In addition, indium foils placed on phantoms were evaluated for the purpose of screening personnel for radiation exposure. All measurements were conducted for unshielded, 5-cm steel and 20-cm concrete shielding configurations. All participant dosimeters were exposed at 3 m from the center of the HPRR core.

  15. Dosimetry for computed tomography using Fricke gel dosimetry and magnetic resonance imaging; Dosimetria em tomografia computadorizada empregando dosimetro Fricke gel e a tecnica de imageamento por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Capeleti, Felipe Favaro; Campos, Leticia L., E-mail: felipe@gmpbrasil.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-04-15

    In this work it was determined a new method for the determination of absorbed doses in Computed Tomography (CT) examinations using Fricke gel dosimetry developed at IPEN. Absorbed doses were determined by different methods of analysis, such as optical absorption spectrometry, ionization chambers and magnetic resonance imaging. Lower limit of sensitivity of the Fricke gel solution, the solution repeatability signal Fricke gel and CT equipment, detection sensitivity, among other tests were performed. Different equipment of computed tomography with multiple detectors were used. The Fricke gel solution showed better repeatability than ±5.5% using the technique of optical absorption spectrophotometry and computed tomography equipment showed repeatability better than ±0.2%. The Fricke gel solution features an easy and relatively quick preparation, but it is necessary to be careful not to contaminate and lose the solution. With the results, it was confirmed the application of this type of dosimetry for computed tomography equipment. (author)

  16. Scientific days on electromagnetic fields: from dosimetry to human health - Conference proceedings; Journees scientifiques - Champs electromagnetiques: de la dosimetrie a la sante humaine - Recueil des resumes et presentations

    Energy Technology Data Exchange (ETDEWEB)

    Wiart, J.; Ghanmi, A.; Picon, O.; Conil, E.; Varsier, N.; Hadjem, A.; Sudret, B.; Magne, I.; Souques, M.; Gaudaire, F.; De Seze, R.; Jawad, O.; Lautru, D.; Dricot, J.M.; Horlin, F.; De Doncker, P.; Drissaoui, A.; Musy, F.; Nicolas, L.; Perrussel, R.; Scorretti, R.; Voyer, D.; Jala, M.; Moulines, E.; Levy-Leduc, C.; Mahfouz, Z.; Gati, A.; Fouad Hanna, V.; Leveque, P.; Arnaud-Cormos, D.; Zhadobov, M.; Jarrige, P.; Gaborit, G.; Kohler, S.; Ticaud, N.; Duvillaret, L.; Guelilia, Z.; Loison, R.; Gillard, R.; Laisne, A.; Favet, D.; Benadhira, R.; Mir, L.; Nadi, M.; Kourtiche, D.; Gazeau, F.; Wilhelm, C.; Delemotte, L.; Breton, M.; Tarek, M.; Marc-Vergnes, J.P.; Yardin, C.; Perrin, A.; Le Drean, Y.; Sauleau, R.; Lambrozo, J.; Selmaoui, B.; Ghosn, R.; Thuroczy, G.; Villegier, A.S.; Loos, N.; Brenet-Dufour, V.; Liabeuf, S.; Bach, V.; Moretti, D.; Lewis, N.; Garenne, A.; Poulletier De Gannes, F.; Haro, E.; Lagroye, I.; Bornat, Y.; Boutaib, Y.; Saighi, S.; Renaud, S.; Veyre, B.; Schuz, J.; Deltour, I.; Van Deventer, E.; Vecchia, P.; Merckel, O.; Bellaouel, A.; Demaret, P.; Donati, P.; Jovanovic, D.; Chauvin, S.; Desreumaux, J.P.; Fouquet, L.; Picard, D.; Massardier-Pilonchery, A.; Hours, M.; Bergeret, A.; Person, C.; Toutain, Y.; Butet, R.; Berrahma, K.; Balderelli, I.; Stelmaszyk, V.; Cretallaz, C.; Lamproglou, I.; Amourette, C.; Diserbo, M.; Fauquette, W.; Martigne, P.; Collin, A.; Lagroye, I.; Ait Aissa, S.; Hurtier, A.; Taxile, M.; Le Montagner, L.; Athane, A.; Duleu, S.; Percherancier, Y.; Geffard, M.; Ruffie, G.; Billaudel, B.; Veyret, B.; Pelletier, A.; Delanaud, S.; Libert, J.P.; Schunck, T.; Bieth, F.; Soubere Mahamoud, Y.; Le Quement, C.; Ferrand, G.; Le Guevel, R.; Carton, P.H.; Luong, M.; Tanvir, S.; Selmaoui, B.; Silva Pires-Antonietti, V.; Sonnet, P.; Pulvin, S.; Kuster, O.; Tetelin, C.

    2012-04-15

    This document brings together the available presentations (articles and slides) given at the URSI scientific days on electromagnetic fields: dosimetry, peoples' exposure, biological and health risks, risk management, and medical uses. 48 presentations are compiled in this document and deal with: 1 - Stochastic dosimetry: variability challenge; 2 - How to estimate the exposure to 50/60 Hz magnetic field in an epidemiological study?; 3 - Joint analysis of population exposure and radio coverage of GSM and UMTS mobile phone networks; 4 - Study of the specific energy absorption rate (SAR) sensitiveness to phone positions near the head for 2 GSM mobile phones; 5 - Statistical Study of SAR under Wireless Channel - Exposure in Indoor Environment; 6 - Uncertainty propagation in numerical dosimetry: how to reduce calculation costs?; 7 - Use of a simplified pregnant woman model for foetus exposure analysis; 8 - SAR estimation using multi-exposure with a mobile phone; 9 - State-of-the-art in experimental dosimetry (RF and pulses); 10 - Mm-waves dosimetry: issues, stakes and actual solutions; 11 - Use of DG-FDTD for a dosimetry calculation in a strongly multi-scale problem: determination of the eye-SAR near a HF/VHF vehicle-borne source; 12 - Dosimetric measurements with a fiber-type electro-optical sensor; 13 - Partial experimental evaluation of basic restrictions in the HF/VHF range; 14 - Repetitive trans-cranial magnetic stimulation Stimulation (rTMS) in psychiatry: present day situation and perspectives; 15 - Medical applications of electric fields; 16 - Measurements for life: new perspectives? 17 - Nano-particles and magnetic stimuli for medical imaging and therapy; 18 - Molecular Insights into electroporation and siRNA electro-transfer through model cell membranes; 19 - State of knowledge on electromagnetic fields hypersensitivity (HS-CEM); 20 - Experimentation methodology: from results to interpretation; 22 - Mm waves - update on biological effects at 40-60 GHz; 23

  17. Enhancing supply vessel safety

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    A supply-vessel bridge installation consists of a navigating bridge and a control position aft, from which operators control the ship when close to rigs or platforms, and operate winches and other loading equipment. The international Convention for Safety of I Ale at Sea (SOLAS) does not regulate the layout, so design varies to a large degree, often causing an imperfect working environment. As for other types of ships, more than half the offshore service vessel accidents at sea are caused by bridge system failures. A majority can be traced back to technical design, and operational errors. The research and development project NAUT-OSV is a response to the offshore industry's safety concerns. Analysis of 24 incidents involving contact or collision between supply vessels and offshore installations owned or operated by Norwegian companies indicated that failures in the bridge system were often the cause.

  18. High-dose dosimetry of beta rays using blue beryl dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do, E-mail: lsatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Bittencour, Jose F., E-mail: Lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear

    2015-07-01

    High dose radiation is widely used in industrial applications as sterilization of medical products, improvement of materials properties, color enhancement of jewelry stones, etc. The radiation dosimetry of high doses is quite important for these applications. In this work we have investigated the usage of blue beryl crystal also known as aquamarine in high dose dosimetry of beta rays. Some works have shown that silicate minerals exhibit a good Thermoluminescent response when irradiated up to 2000 kGy of gamma rays. Here, we have produced small beryl pellets of approximately 5 mm in diameter and 3 mm thickness to measure high doses of beta rays produced at an electron accelerator at IPEN. Twelve beryl dosimeters were made and six of them were irradiated from 10kGy up to 100 kGy. The technique used to create a calibration curve was the thermoluminescence using the glow peak at 310°C. (author)

  19. Microwave dielectric absorption spectroscopy aiming at novel dosimetry using DNAs

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Yoshinobu; Hirayama, Makoto; Matuo, Youichirou [Research Institute of Nuclear Engineering, University of Fukui, Fukui (Japan); Sunagawa, Takeyoshi [Fukui University of Technology, Fukui (Japan)

    2017-03-15

    We are developing L-band and S-band microwave dielectric absorption systems aiming novel dosimetry using DNAs, such as plasmid DNA and genomic DNA, and microwave technology. Each system is composed of a cavity resonator, analog signal generator, circulator, power meter, and oscilloscope. Since the cavity resonator is sensitive to temperature change, we have made great efforts to prevent the fluctuation of temperature. We have developed software for controlling and measurement. By using this system, we can measure the resonance frequency, f, and ΔQ (Q is a dimensionless parameter that describes how under-damped an oscillator or resonator is, and characterizes a resonator’s bandwidth relative to its center frequency) within about 3 minutes with high accuracy. This system will be expected to be applicable to DNAs evaluations and to novel dosimetric system.

  20. Thermoluminescent dosimetry in total body irradiation.

    Science.gov (United States)

    Rodríguez-Cortés, J; Rivera-Montalvo, T; Villaseñor Navarro, L F; Flores-López, O; Roman, J; Hernandez-Oviedo, J O

    2012-12-01

    The aim of this paper was to develop a thermoluminescent dosimetry method for the absorbed dose determination of 6 MeV high-energy electron beams by thermoluminescent dosimetry. Total body irradiation (TBI) was performed using four dual fields angled at 252° and 285° in high-dose rate (HDR) mode. TBI measurements were investigated to estimate the absorbed dose in different anatomical parts of the patient. Experimental results were obtained using thermoluminescent detectors and solid water phantoms. The TL response of the dosimeters, as a function of the high-energy electron beam (HEEB) absorbed dose, was linear, from 0.1 to 500 cGy. The entrance skin dose (ESD) and isodose distribution on the surface of the treatment were investigated graphically. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Trigeminal neuralgia treatment dosimetry of the Cyberknife

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Anthony [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Lo, Anthony T., E-mail: tonyho22003@yahoo.com [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Dieterich, Sonja; Soltys, Scott G.; Gibbs, Iris C. [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Chang, Steve G.; Adler, John R. [Department of Neurosurgery, Stanford University, Stanford, CA (United States)

    2012-04-01

    There are 2 Cyberknife units at Stanford University. The robot of 1 Cyberknife is positioned on the patient's right, whereas the second is on the patient's left. The present study examines whether there is any difference in dosimetry when we are treating patients with trigeminal neuralgia when the target is on the right side or the left side of the patient. In addition, we also study whether Monte Carlo dose calculation has any effect on the dosimetry. We concluded that the clinical and dosimetric outcomes of CyberKnife treatment for trigeminal neuralgia are independent of the robot position. Monte Carlo calculation algorithm may be useful in deriving the dose necessary for trigeminal neuralgia treatments.

  2. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2005-02-25

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database.

  3. Performance studies of an optical fiber OSL/RL dosimetry system in pulsed high-intensity radiation beams

    CERN Document Server

    Ravotti, F; Dusseau, Laurent; Mukherjee, Bhaskar; Glaser, Maurice; Ravotti, Federico

    2010-01-01

    The SrS:Ce,Sm phosphor is suitable for operation in harsh radiation environments where real-time dosimetry measurements are needed to survey the Total Ionizing Dose (TID) damage in electronic components. For these applications, the OSL and RL emissions from this phosphor can be exploited by mounting the SrS crystal at the edge of a single, radiation-hard, optical fiber. In this work we present an exhaustive characterization of this real-time OSL/RL probe including stability, repeatability of the measured signals, dosimetry performance and measurements of the temporal behavior of the RI signal in pulsed particle beams. (C) 2009 Elsevier Ltd. All rights reserved.

  4. Neutron dosimetry. Environmental monitoring in a BWR type reactor; Dosimetria de neutrones. Monitoreo ambiental en un reactor del tipo BWR

    Energy Technology Data Exchange (ETDEWEB)

    Tavera D, L.; Camacho L, M.E

    1991-01-15

    The measurements carried out on reactor dosimetry are applied mainly to the study on the effects of the radiation in 108 materials of the reactor; little is on the environmental dosimetry outside of the primary container of BWR reactors. In this work the application of a neutron spectrometer formed by plastic detectors of nuclear traces manufactured in the ININ, for the environmental monitoring in penetrations around the primary container of the unit I of the Laguna Verde central is presented. The neutron monitoring carries out with purposes of radiological protection, during the operational tests of the reactor. (Author)

  5. Experimental study of laminar and turbulent flame speed of a spherical flame in a fan-stirred closed vessel for hydrogen safety application

    Energy Technology Data Exchange (ETDEWEB)

    Goulier, J. [Institut de Combustion, Aérothermique, Réactivité et Environnement, CNRS-ICARE (France); Institut de Radioprotection et de Sûreté Nucléaire (IRSN) (France); Chaumeix, N., E-mail: chaumeix@cnrs-orleans.fr [Institut de Combustion, Aérothermique, Réactivité et Environnement, CNRS-ICARE (France); Halter, F. [Institut de Combustion, Aérothermique, Réactivité et Environnement, CNRS-ICARE (France); Meynet, N.; Bentaïb, A. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN) (France)

    2017-02-15

    The aim of this paper is to report new experimental results on the effect of turbulence on the propagation speed of hydrogen/air flames. To do so, a new experimental setup, called the spherical bomb, has been designed and built at CNRS-ICARE laboratory. With this new setup, the effect of a given and well-characterized turbulence intensity on the increase of hydrogen/air flame speed can be investigated. This new facility consists of a spherical vessel equipped (563 mm internal diameter) equipped with 8 motors which are linked to fans inside the bomb. Fan actuation induces the generation of a turbulent flow inside the vessel prior to any ignition. The spherical bomb is equipped with 4 quartz windows (200 mm optical diameter) that allow the use of a Particle Image Velocimetry diagnostic in order to characterize the turbulence level inside the bomb. The flame propagation was recorded using a high speed camera at 19,002 frames per second. These experiments were performed for lean to stoichiometric hydrogen/air mixtures (16–20% of H{sub 2} in air), initially at ambient temperature and pressure, and for a rotation speed from 1000 to 5000 rpm. The PIV measurements showed that a homogeneous and isotropic turbulence is created with a fluctuation speed that can reach 4 m/s at 5000 rpm.

  6. WE-F-201-02: Review TG-186 and WGMBDCA Guidelines, Commission Process, and Dosimetry Benchmarks

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, M. [Tufts University School of Medicine, Boston, MA (United States)

    2015-06-15

    With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of the clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.

  7. Vessel detection in ultrasound images using deep convolutional neural networks

    OpenAIRE

    Smistad, Erik; Løvstakken, Lasse

    2016-01-01

    Deep convolutional neural networks have achieved great results on image classification problems. In this paper, a new method using a deep convolutional neural network for detecting blood vessels in B-mode ultrasound images is presented. Automatic blood vessel detection may be useful in medical applications such as deep venous thrombosis detection, anesthesia guidance and catheter placement. The proposed method is able to determine the position and size of the vessels in images in real-time. 1...

  8. Radiation-Induced Color Centers in LiF for Dosimetry at High Absorbed Dose Rates

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Miller, Arne; Ellis, S. C.

    1980-01-01

    Color centers formed by irradiation of optically clear crystals of pure LiF may be analyzed spectrophotometrically for dosimetry in the absorbed dose range from 102 to 107 Gy. Routine monitoring of intense electron beams is an important application. Both 6LiF and 7LiF forms are commercially avail...... available, and when used with filters as albedo dosimeters in pairs, they provide discrimination of neutron and gamma-ray doses....

  9. Dosimetry of ionizing radiations by Electron paramagnetic resonance; Dosimetria de radiaciones ionizantes por resonancia paramagnetica electronica

    Energy Technology Data Exchange (ETDEWEB)

    Azorin N, J. [UAM-I, Av. San Rafael Atlixco 186, 09340 Mexico D.F. (Mexico)

    2005-07-01

    In this work, some historical and theoretical aspects about the Electron Paramagnetic Resonance (EPR), its characteristics, the resonance detection, the paramagnetic species, the radiation effects on inorganic and organic materials, the diagrams of the instrumentation for the EPR detection, the performance of an EPR spectrometer, the coherence among EPR and dosimetry and, practical applications as well as in the food science there are presented. (Author)

  10. Optically stimulated luminescence of YAlO{sub 3}:Mn{sup 2+} for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Zhydachevskii, Ya. [Lviv Polytechnic National University, 12 Bandera, 79646 Lviv (Ukraine)], E-mail: crystal@polynet.lviv.ua; Suchocki, A.; Berkowski, M. [Institute of Physics, Polish Academy of Sciences, 32/46 Al. Lotnikow, 02668 Warsaw (Poland); Zakharko, Ya. [I.Franko Lviv National University, 107 Tarnavskogo St., 79017 Lviv (Ukraine)

    2007-04-15

    The optically stimulated luminescence (OSL) properties have been studied for YAlO{sub 3}:Mn{sup 2+} crystal applicable for thermoluminescent (TL) dosimetry of ionizing radiation and UV light. A high efficiency of optical stimulation by the blue-green light (450-500 nm) was demonstrated that allows to use the OSL procedure for non-heating readout of the irradiated samples. Mechanisms of the observed optical processes are discussed.

  11. {sup 177}Lutetium-DOTATATE peptide radio-receptor therapy for patients with endocrine neoplasm and the individualized semi-automatic dosimetry. A retrospective analysis; {sup 177}Lutetium-DOTATATE-Peptid-Radio-Rezeptor-Therapie bei Patienten mit neuroendokrinen Neoplasien und die individualisierte, semi-automatische-Dosimetrie. Eine retrospektive Analyse

    Energy Technology Data Exchange (ETDEWEB)

    Loeser, Anastassia

    2016-09-28

    The {sup 177}lutetium-DOTATATE peptide radio-receptor therapy is a promising approach for the palliative treatment of patients with inoperable endocrine neoplasm. The individually variable biological dispersion and the tumor uptake including the protection of critical organs require a precise and reliable organ and tumor dosimetry. The HERMES Hybrid dosimetry module has appeared as reliable and user-friendly tool for clinical application. The next step is supposed to by the complete integration of 3D SPECT imaging.

  12. In vivo dosimetry in external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mijnheer, Ben [Department of Radiation Oncology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam 1066 CX (Netherlands); Beddar, Sam [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Izewska, Joanna [Division of Human Health, International Atomic Energy Agency, Vienna 1400 (Austria); Reft, Chester [Department of Radiation and Cellular Oncology, University of Chicago Medical Center, Chicago, Illinois 60637 (United States)

    2013-07-15

    In vivo dosimetry (IVD) is in use in external beam radiotherapy (EBRT) to detect major errors, to assess clinically relevant differences between planned and delivered dose, to record dose received by individual patients, and to fulfill legal requirements. After discussing briefly the main characteristics of the most commonly applied IVD systems, the clinical experience of IVD during EBRT will be summarized. Advancement of the traditional aspects of in vivo dosimetry as well as the development of currently available and newly emerging noninterventional technologies are required for large-scale implementation of IVD in EBRT. These new technologies include the development of electronic portal imaging devices for 2D and 3D patient dosimetry during advanced treatment techniques, such as IMRT and VMAT, and the use of IVD in proton and ion radiotherapy by measuring the decay of radiation-induced radionuclides. In the final analysis, we will show in this Vision 20/20 paper that in addition to regulatory compliance and reimbursement issues, the rationale for in vivo measurements is to provide an accurate and independent verification of the overall treatment procedure. It will enable the identification of potential errors in dose calculation, data transfer, dose delivery, patient setup, and changes in patient anatomy. It is the authors' opinion that all treatments with curative intent should be verified through in vivo dose measurements in combination with pretreatment checks.

  13. Bayesian Methods for Radiation Detection and Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Peter G. Groer

    2002-09-29

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed compartmental activities. From the estimated probability densities of the model parameters we were able to derive the densities for compartmental activities for a two compartment catenary model at different times. We also calculated the average activities and their standard deviation for a simple two compartment model.

  14. Electron paramagnetic resonance dosimetry using synthetic hydroxyapatite

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kwon; Kim, Hwi Young; Ye, Sung Joon [Seoul National University, Seoul (Korea, Republic of); Hirata, Hiroshi [Hokkaido University, Sapporo (Japan); Park, Jong Min [Seoul National University Hospital, Seoul (Korea, Republic of)

    2014-11-15

    The victims exposed doses under 3.5-4.0 Gy have chance to survive if treated urgently. To determine the priority of treatment among a large number of victims, the triage – distinguishing patients who need an urgent treatment from who may not be urgent – is necessary based on radiation biodosimetry. A current gold standard for radiation biodosimetry is the chromosomal assay using human lymphocytes. But this method requires too much time and skilled labors to cover the mass victims in radiation emergencies. Electron paramagnetic resonance (EPR) has been known for its capability of quantifying radicals in matters. EPR dosimetry is based on the measurement of stable radiation-induced radicals in tooth enamel. Hydroxyapatite (HAP) (Ca10(PO4)6(OH)2) contained in tooth enamel is a major probe for radiation dose reconstruction. This HAP dosimetry study was performed using a novel EPR spectrometer in Hokkaido University, Japan. The EPR dose-response curve was made using HAP samples. The blind test using 250 cGy samples showed the feasibility of EPR dosimetry for the triage purpose.

  15. Reconstructive dosimetry for cutaneous radiation syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lima, C.M.A.; Lima, A.R.; Degenhardt, Ä.L.; Da Silva, F.C.A., E-mail: dasilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Valverde, N.J. [Fundacao Eletronuclear de Assistencia Medica, Rio de Janeiro, RJ (Brazil)

    2015-10-15

    According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry. (author)

  16. Retrospective dosimetry: Estimation of the dose to quartz using the single-aliquot regenerative-dose protocol

    DEFF Research Database (Denmark)

    Banerjee, D.; Bøtter-Jensen, L.; Murray, A.S.

    2000-01-01

    We report on the application of the single-aliquot regenerative-dose protocol to retrospective dosimetry, using the optically stimulated luminescence (OSL) from quartz extracted from fired bricks. These bricks had previously been exposed to enhanced levels of ionising radiation while part...

  17. GOLD PRESSURE VESSEL SEAL

    Science.gov (United States)

    Smith, A.E.

    1963-11-26

    An improved seal between the piston and die member of a piston-cylinder type pressure vessel is presented. A layer of gold, of sufficient thickness to provide an interference fit between the piston and die member, is plated on the contacting surface of at least one of the members. (AEC)

  18. Network of endocardial vessels.

    Science.gov (United States)

    Lee, Byung-Cheon; Kim, Hong Bae; Sung, Baeckkyoung; Kim, Ki Woo; Sohn, Jamin; Son, Boram; Chang, Byung-Joon; Soh, Kwang-Sup

    2011-01-01

    Although there have been reports on threadlike structures inside the heart, they have received little attention. We aimed to develop a method for observing such structures and to reveal their ultrastructures. An in situ staining method, which uses a series of procedures of 0.2-0.4% trypan blue spraying and washing, was applied to observe threadlike structures on the surfaces of endocardia. The threadlike structures were isolated and observed by using confocal laser scanning microscopy (CLSM) and transmission electron microscopy (TEM). Networks of endocardial vessels (20 μm in thickness) with expansions (40-100 μm in diameter) were visualized; they were movable on the endocardium of the bovine atrium and ventricle. CLSM showed that (1) rod-shaped nuclei were aligned along the longitudinal direction of the endocardial vessel and (2) there were many cells inside the expansion. TEM on the endocardial vessel revealed that (1) there existed multiple lumens (1-7 μm in diameter) and (2) the extracellular matrices mostly consisted of collagen fibers, which were aligned along the longitudinal direction of the endocardial vessel or were locally organized in reticular structures. We investigated the endocardial circulatory system in bovine cardiac chambers and its ultrastructures, such as nucleic distributions, microlumens, and collagenous extracellular matrices. Copyright © 2011 S. Karger AG, Basel.

  19. Pressurized Vessel Slurry Pumping

    Energy Technology Data Exchange (ETDEWEB)

    Pound, C.R.

    2001-09-17

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air.

  20. 78 FR 38102 - Passenger Vessels Accessibility Guidelines

    Science.gov (United States)

    2013-06-25

    ... vessels a limited use-limited application elevator (LULA) or platform lift, would be required to connect..., we estimate an elevator to cost $371,000; a LULA to cost $297,400; and a platform lift to cost $108.... See 42 U.S.C. 12101 et seq. Title II of the ADA applies to state and local governments and Title III...

  1. The application of mechanical and thermal cutting tools for the dismantling of activated internals of the reactor pressure vessels in the Versuchsatomkraftwerk, Kahl and the Gundremmingen Unit A

    Energy Technology Data Exchange (ETDEWEB)

    Eickelpasch, N. [Versuchsatomkraftwerk GmbH, Kahl am Main (Germany); Kalwa, H. [Versuchsatomkraftwerk GmbH, Kahl am Main (Germany); Steiner, H. [Kernkraftwerke Gundremmingen Betriebsgesellschaft mbH, D-89355 Gundremmingen (Germany); Priesmeyer, U. [Kernkraftwerke Gundremmingen Betriebsgesellschaft mbH, D-89355 Gundremmingen (Germany)

    1997-07-01

    The Gundremmingen Unit A plant (KRB A) and the Versuchsatomkraftwerk Kahl (VAK) plant represent the first generation of nuclear reactors in Germany. The 250 MW{sub e} reactor KRB A was the first commercial reactor in Germany and the 16 MW{sub e} reactor VAK was the pilot nuclear power plant, which had to serve mainly scientific purposes. KRB A is under dismantling since 1983, VAK since 1988. Although they are both of the boiling water type, they are rather different to each other, referring to their size and construction. The actual work is the dismantling of high contaminated components inside the reactor buildings and the underwater cutting of activated internals of the reactor pressure vessels. Several cutting techniques have been developed, tested and applied to respective dismantling tasks in the meantime. The experiences made in both projects are not limited to dismantling work only, but also include know-how on effective decontamination and scrap recycling. (orig.)

  2. 78 FR 23823 - Requested Administrative Waiver of the Coastwise Trade Laws: Vessel FISHIN GAME; Invitation for...

    Science.gov (United States)

    2013-04-22

    ... From the Federal Register Online via the Government Publishing Office ] DEPARTMENT OF... GAME; Invitation for Public Comments AGENCY: Maritime Administration, Department of Transportation... the applicant the intended service of the vessel FISHIN GAME is: Intended Commercial Use Of Vessel...

  3. In vivo dosimetry by an aSi-based EPID.

    Science.gov (United States)

    Piermattei, Angelo; Fidanzio, Andrea; Stimato, Gerardina; Azario, Luigi; Grimaldi, Luca; D'Onofrio, Guido; Cilla, Savino; Balducci, Mario; Gambacorta, Maria Antonietta; Di Napoli, Nicola; Cellini, Numa

    2006-11-01

    A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoiding many of the disadvantages associated with the use of two diode detectors (at the entrance and exit of the patient) as their periodic recalibration and their positioning. Irradiating water-equivalent phantoms of different thicknesses, a set of correlation functions F(w, l) were obtained by the ratio between St and Dm as a function of the phantom thickness, w, for a different field width, l. For the in vivo determination of Diso and Dm values, the water-equivalent thickness of the patients (along the beam central axis) was evaluated by means of the treatment planning system that uses CT scans calibrated in terms of the electron densities. The Diso and Dm values experimentally determined were compared with the stated doses D(iso,TPS) and D(m,TPS), determined by the treatment planning system for ten pelvic treatments. In particular, for each treatment four fields were checked in six fractions. In these conditions the agreement between the in vivo dosimetry and stated doses at the isocenter point were within 3%. Comparing the 480 dose values obtained in this work with those obtained for 30 patients tested with a similar method, which made use of a small ion-chamber positioned on the EPIDs to obtain the transmitted signal, a similar agreement was observed. The method here proposed is very practical and can be applied in every treatment fraction, supplying useful information about eventual patient dose variations due to the incorrect application of the quality assurance program based on the check of patient setup, machine setting, and calculations.

  4. Present status and expected progress in radiation processing dosimetry

    DEFF Research Database (Denmark)

    Kovács, A.; Miller, A.

    2004-01-01

    The paper describes the present status of radiation processing dosimetry including the methods used most widely in gamma- and electron processing as well as the new methods under development or introduction. The recent trends with respect to calibrationof routine dosimetry systems as well...

  5. Dosimetry of internal emitting: principles and perspectives of the MIRD technology; Dosimetria de emisores internos: principios y perspectivas de la metodologia MIRD

    Energy Technology Data Exchange (ETDEWEB)

    Ferro F, G. [Gerencia de Aplicaciones Nucleares en la Salud, Instituto Nacional de Investigaciones Nucleares, Salazar, Estado de Mexico C.P. 52045 (Mexico)

    1999-07-01

    The development of the radiopharmaceutical technology have multiplied the number of radioisotopes with applications in therapeutical nuclear medicine so known as Directed radiotherapy. Assuming the radiation is capable to produce noxious effects in the biological systems, it is important to evaluate appropriately the risks and benefits of the administration of radioactive agents in the patient. The outstanding parameter in this evaluation is the absorbed dose, which is product of the radiation emitted by a radionuclide that is localized or distributed to the interior of the human body in study and whose its estimation helps to predict the efficacy of the treatment. The scheme generalized of MIRD, it was formulated from thirty years ago for evaluating the interior dosimetry at level of organs.The finality of this work is to show the basic principles of the MIRD methodology and its perspectives using innovator tools as the dosimetry for dynamic masses, in particular the personnel dosimetry for the organs of each patient, the dosimetry for the small structures inside the organs (sub organic dosimetry), the distributions of doses in three dimensions (S voxel), the dosimetry at cellular level and the quantitative acquisition of pharmaceutical data. (Author)

  6. Hawaii Abandoned Vessel Inventory, Kauai

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Kauai. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  7. CNMI Abandoned Vessel Inventory, Tinian

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Tinian. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  8. Puerto Rico Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Puerto Rico. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  9. American Samoa Abandoned Vessel Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for American Samoa. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  10. Hawaii Abandoned Vessel Inventory, Oahu

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Oahu, Hawaii. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  11. Hawaii Abandoned Vessel Inventory, Molokai

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Molokai, Hawaii. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral...

  12. CNMI Abandoned Vessel Inventory, Rota

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Rota. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  13. Hawaii Abandoned Vessel Inventory, Lanai

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Lanai. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  14. For-Hire Vessel Directory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Vessel Directory is maintained as the sample frame for the For-Hire Survey. I contains data on for-hire vessels on the Atlantic and Gulf coasts. Data include...

  15. CNMI Abandoned Vessel Inventory, Saipan

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Saipan. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  16. Hawaii Abandoned Vessel Inventory, Maui

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Abandoned Vessel Project Data for Maui. Abandoned vessels pose a significant threat to the NOAA Trust resources through physical destruction of coral habitats...

  17. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  18. Radiolytic model of CN Cofrentes using BWRVIA: analysis of the effectiveness of mitigation in locations of the vessel with application of noble metal son-line; Modelo radiolitico de C. N: Cofrentes utilizando el BWRVIA: analisis de la efectividad de mitigacion en localizaciones de la vasija con aplicacion de metales nobles on-line

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Serrano Ledesma, C.; Sanchez Zapata, J. D.

    2012-07-01

    The effectiveness of mitigation is found from two chemical parameters: electrochemical potential (pm-a hydrogen injection) and Molar Ratio (for the application of noble metals). EPRI code exists, the BWRVIA (BWR Vessel Internals Application,) which enables setting model the impact radiolysis of water, the balance of liquid-vapor phase and recirculation have on the chemical variation of these parameters.

  19. Pressure vessel design manual

    Energy Technology Data Exchange (ETDEWEB)

    Moss, D.R.

    1987-01-01

    The first section of the book covers types of loadings, failures, and stress theories, and how they apply to pressure vessels. The book delineates the procedures for designing typical components as well as those for designing large openings in cylindrical shells, ring girders, davits, platforms, bins and elevated tanks. The techniques for designing conical transitions, cone-cylinder intersections, intermediate heads, flat heads, and spherically dished covers are also described. The book covers the design of vessel supports subject to wind and seismic loads and one section is devoted to the five major ways of analyzing loads on shells and heads. Each procedure is detailed enough to size all welds, bolts, and plate thicknesses and to determine actual stresses.

  20. New research vessels

    Science.gov (United States)

    1984-04-01

    Two “new” ocean-going research vessels operated by the Scripps Institution of Oceanography and the National Science Foundation (NSF) will soon begin full-time scientific duties off the coast of California and in the Antarctic, respectively. The 37.5-m Scripps vessel, named Robert Gordon Sprout in honor of the ex-president of the University of California, replaces the smaller ship Ellen B. Scripps, which had served the institution since 1965. The new ship is a slightly modified Gulf Coast workboat. Under the name of Midnight Alaskan, it had been used for high-resolution geophysical surveys in American and Latin American waters by such firms as Arco Oil & Gas, Exxon, Pennzoil, and Racal-Decca before its purchase by Scripps from a Lousiana chartering firm last summer.

  1. Biological dosimetry of irradiation accidents; La dosimetrie biologique des accidents d`irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Durand, V.; Chambrette, V.; Le Roy, A.; Paillole, N.; Sorokine, I.; Voisin, P.

    1994-12-31

    The biological dosimetry in radiation protection allows to evaluate the received dose by a potentially irradiated person from biological markers such chromosomal abnormalities. The technologies of Hybridization In Situ by Fluorescence (F.I.S.H) allow the detection of steady chromosomal aberrations of translocation type.

  2. Large vessel vasculitides

    OpenAIRE

    Morović-Vergles, Jadranka; Pukšić, Silva; Gudelj Gračanin, Ana

    2013-01-01

    Large vessel vasculitis includes Giant cell arteritis and Takayasu arteritis. Giant cell arteritis is the most common form of vasculitis affect patients aged 50 years or over. The diagnosis should be considered in older patients who present with new onset of headache, visual disturbance, polymyalgia rheumatica and/or fever unknown cause. Glucocorticoides remain the cornerstone of therapy. Takayasu arteritis is a chronic panarteritis of the aorta ant its major branches presenting commonly in y...

  3. Very Versatile Vessel

    Science.gov (United States)

    2009-09-01

    data. This source provides information on aluminum hydrofoil vessels without the added weight of foil structures. The composite armor around the...seating compartment. The sides should also limit wave splash on the deck. The freeboard should contribute reserve buoyancy , increasing large-angle and...Resistance, Powering, and Propulsion Savitsky’s Method Since model testing data or other reliable performance data was unavailable for the proposed

  4. Internal in vitro dosimetry for fish using hydroxyapatite-based EPR detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, D.V. [Urals Division of Russian Academy of Sciences, Institute of Metal Physics, Yekaterinburg (Russian Federation); Ural Federal University, Yekaterinburg (Russian Federation); Shishkina, E.A.; Osipov, D.I.; Pryakhin, E.A. [Urals Research Center for Radiation Medicine, Chelyabinsk (Russian Federation); Razumeev, R.A. [Ural Federal University, Yekaterinburg (Russian Federation)

    2015-08-15

    A number of aquatic ecosystems were exposed to ionizing radiation as a result of the activities of the Mayak Production Association in the Southern Urals, former Soviet Union, in the 1950s. Currently, fishes inhabiting contaminated lakes are being actively studied. These investigations need dosimetric support. In the present paper the results of a pilot study for elaborating an EPR dosimeter which can be used for internal dosimetry in vitro are described. Biological hydroxyapatite is proposed here to be used as a detecting substance. More specifically, small hydroxyapatite grains are proposed for use as point detectors fixed in a solid matrix. After having been pelletized, the detectors were covered by Mylar and placed in the body of a fish to be stored in the fridge for several months. Application of the detectors for internal fish dosimetry demonstrated that the enamel sensitivity is sufficient for passive detection of ionizing radiation in fishes inhabiting contaminated lakes in the Southern Urals. (orig.)

  5. Cerium-activated sol-gel silica glasses for radiation dosimetry in harsh environment

    Science.gov (United States)

    El Hamzaoui, Hicham; Capoen, Bruno; Helou, Nissrine Al; Bouwmans, Géraud; Ouerdane, Youcef; Boukenter, Aziz; Girard, Sylvain; Marcandella, Claude; Duhamel, Olivier; Chadeyron, Geneviève; Mahiou, Rachid; Bouazaoui, Mohamed

    2016-04-01

    Cerium-doped silica glass has been prepared for ionizing radiation dosimetry applications, using the sol-gel route and densification under different atmospheres. In comparison with the glass densified under air atmosphere, the one obtained after sintering the xerogel under helium gas presents improved optical properties, with an enhancement of the photoluminescence quantum yield up to 33%, which is attributed to a higher Ce3+ ions concentration. Such a glassy rod has been jacketed in a quartz tube and then drawn at high temperature to a cane, which has been used as active material in a fibered remote x-ray radiation dosimeter. The sample exhibited a reversible linear radioluminescence intensity response versus the dose rate up to 30 Gy s-1. These results confirm the potentialities of this material for in vivo or high rate dose remote dosimetry measurements.

  6. Imaging and dosimetry for radium-223: the potential for personalized treatment.

    Science.gov (United States)

    Flux, Glenn D

    2017-08-01

    Radium-223 ((223)Ra) offers a new option for the treatment of bone metastases from prostate cancer. As cancer treatment progresses towards personalization, the potential for an individualized approach is exemplified in treatments with radiotherapeutics due to the unique ability to image in vivo the uptake and retention of the therapeutic agent. This is unmatched in any other field of medicine. Currently, (223)Ra is administered according to standard fixed administrations, modified according to patient weight. Although gamma emissions comprise only 1% of the total emitted energy, there are increasing reports that quantitative imaging is feasible and can facilitate patient-specific dosimetry. The aim of this article is to review the application of imaging and dosimetry for (223)Ra and to consider the potential for treatment optimization accordingly, in order to ensure clinical and cost effectiveness of this promising agent.

  7. Development of a new software tool, based on ANN technology, in neutron spectrometry and dosimetry research

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz R, J.M.; Martinez B, M.R.; Vega C, H.R. [Universidad Autonoma de Zacatecas, Av. Ramon Lopez Velarde 801, A.P. 336, 98000 Zacatecas (Mexico)

    2007-07-01

    Artificial Intelligence is a branch of study which enhances the capability of computers by giving them human-like intelligence. The brain architecture has been extensively studied and attempts have been made to emulate it as in the Artificial Neural Network technology. A large variety of neural network architectures have been developed and they have gained wide-spread popularity over the last few decades. Their application is considered as a substitute for many classical techniques that have been used for many years, as in the case of neutron spectrometry and dosimetry research areas. In previous works, a new approach called Robust Design of Artificial Neural network was applied to build an ANN topology capable to solve the neutron spectrometry and dosimetry problems within the Mat lab programming environment. In this work, the knowledge stored at Mat lab ANN's synaptic weights was extracted in order to develop for first time a customized software application based on ANN technology, which is proposed to be used in the neutron spectrometry and simultaneous dosimetry fields. (Author)

  8. Sandia National Laboratories Internal Dosimetry Technical Basis Manual (Rev 4)

    Energy Technology Data Exchange (ETDEWEB)

    Goke, Sarah Hayes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Elliott, Nathan Ryan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    The Sandia National Laboratories’ Internal Dosimetry Technical Basis Manual is intended to provide extended technical discussion and justification of the internal dosimetry program at SNL. It serves to record the approach to evaluating internal doses from radiobioassay data, and where appropriate, from workplace monitoring data per the Department of Energy Internal Dosimetry Program Guide DOE G 441.1C. The discussion contained herein is directed primarily to current and future SNL internal dosimetrists. In an effort to conserve space in the TBM and avoid duplication, it contains numerous references providing an entry point into the internal dosimetry literature relevant to this program. The TBM is not intended to act as a policy or procedure statement, but will supplement the information normally found in procedures or policy documents. The internal dosimetry program outlined in this manual is intended to meet the requirements of Federal Rule 10CFR835 for monitoring the workplace and for assessing internal radiation doses to workers.

  9. Experimental dosimetry of a 32P catheter-based endovascular brachytherapy source

    Science.gov (United States)

    Piermattei, A.; Fidanzio, A.; Perrone, F.; Azario, L.; Grimaldi, L.; Viola, P.; Capote, R.

    2003-08-01

    The experimental dosimetry in a water phantom of a 32P linear source, 20 mm in length, used for the brachytherapy of coronary vessels is reported. The source content activity, A, was determined by means of a calibrated well ion-chamber and the value was compared with the contained activity reported in the manufacturer's certification. In this field of brachytherapy dosimetry, radiochromic film supplies a high enough spatial resolution. A highly sensitive radiochromic film, that presents only one active layer, was used in this work for the source dosimetry in a water phantom. The radiochromic film was characterized by electron beams produced by a clinical linac. A Monte Carlo calculation of beta spectra in water at different distances along the source transverse bisector axis allowed to take into account the low dependence of film response from the electron beam energy. The adopted experimental set-up, with the source in its catheter positioned on the film plane inside the water phantom, supplies accurate dosimetric information. The measured dose rate to water per unit of source activity at reference distance, dot D(r0, theta0)/A, in units of cGy s-1 GBq-1, was in agreement with the value reported in the manufacturer's certification within the experimental uncertainty. The radial dose function, g(r), is in good agreement with the literature data. The anisotropy function F(r, theta) is also reported. The analysis of the dose profile obtained at 2 mm from the source longitudinal axis shows that the uniformity is within 10% along 75% of the 20 mm treatment length. The adopted experimental set-up seems to be adequate for the quality control procedure of the dose homogeneity distribution in the water medium.

  10. FLUOLE-2: An Experiment for PWR Pressure Vessel Surveillance

    Directory of Open Access Journals (Sweden)

    Thiollay Nicolas

    2016-01-01

    Full Text Available FLUOLE-2 is a benchmark-type experiment dedicated to 900 and 1450 MWe PWR vessels surveillance dosimetry. This two-year program started in 2014 and will end in 2015. It will provide precise experimental data for the validation of the neutron spectrum propagation calculation from core to vessel. It is composed of a square core surrounded by a stainless steel baffe and internals: PWR barrel is simulated by steel structures leading to different steel-water slides; two steel components stand for a surveillance capsule holder and for a part of the pressure vessel. Measurement locations are available on the whole experimental structure. The experimental knowledge of core sources will be obtained by integral gamma scanning measurements directly on fuel pins. Reaction rates measured by calibrated fission chambers and a large set of dosimeters will give information on the neutron energy and spatial distributions. Due to the low level neutron flux of EOLE ZPR a special, high efficiency, calibrated gamma spectrometry device will be used for some dosimeters, allowing to measure an activity as low as 7. 10−2 Bq per sample. 103mRh activities will be measured on an absolute calibrated X spectrometry device. FLUOLE-2 experiment goal is to usefully complete the current experimental benchmarks database used for the validation of neutron calculation codes. This two-year program completes the initial FLUOLE program held in 2006–2007 in a geometry representative of 1300 MWe PWR.

  11. Reference dosimetry and small-field dosimetry in external beam radiotherapy: Results from a Danish intercomparison study

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, Claus F.; Sibolt, Patrik

    performed using the treatment planning systems. Measured output factors agreed within 3 % with commissioning beam data and within 2 % with dose calculations for small MLC-defined fields. The study demonstrated (i) consistency of reference dosimetry and small-field dosimetry on a national le-vel, and (ii...

  12. PREFACE: The 5th International Conference on Radiotherapy Gel Dosimetry (DOSGEL 2008)

    Science.gov (United States)

    Maris, Thomas G.; Pappas, Evangelos

    2009-07-01

    The International Conference on Radiotherapy Gel Dosimetry (DOSGEL) is held every two years. Its purpose is to bring together basic science and clinical researchers, medical physicists and clinicians from around the world to discuss the state-of-the-art of the gel dosimetry technique and to set the directions and trends for its future improvements. Gel dosimetry can be broadly defined as using a gel that can react to the absorption of ionizing radiation, and that can retain this information which can subsequently be retrieved by an external imaging modality. Examples of radiation-sensitive gels include, but are not limited to, polymer gel dosimeters, Fricke gel dosimeters and others. Imaging modalities that are of general use in this field are (in alphabetical order) magnetic resonance imaging (MRI), optical light computed tomography and x-ray computed tomography. This volume comprises the proceedings of the 5th International Conference on Radiotherapy Gel Dosimetry (DOSGEL 2008). The conference, organised by the University of Crete, Medical Physics Department, took place in Hersonissos, Crete, Greece from 29 September to 3 October 2008. The meeting aimed to continue the series of biannual DOSGEL conferences and focused on the promotion of gel dosimetry techniques by setting the trends for their future improvements. The main scientific session topics of DOSGEL 2008 were the following: Chemistry and fundamental properties of polymer gel dosimeters Gel dosimetry with Optical Computed Tomography Gel dosimetry with Magnetic Resonance Imaging Gel dosimetry with other than Optical CT and MR scan Techniques Other 3D dosimeters Gel dosimetry applications Local Organizing Committee Thomas G Maris (University of Crete, Greece, Chairman DOSGEL 2008) John Damilakis (University of Crete, Greece) Evangelos Pappas (University of Crete, Greece) Antonios Papadakis (University of Crete, Greece) Fotini Zacharopoulou (University of Crete, Greece) John Stratakis (University of Crete

  13. Retrospective accident dosimetry using trapped charges

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. I.; Kim, J. L.; Chang, I.; Kim, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Dicentric chromosome aberrations technique scoring of aberrations in metaphases prepared from human lymphocytes is most commonly used. This is considered as a reliable technique because the sample is extracted from the individual human body itself. There are other techniques in biological dosimetry such as Fluorescence In Situ Hybridization (FISH) using translocations, premature chromosome condensation (PCC) and micronucleus assay. However the minimum detectable doses (MDD) are relatively high and sample preparation time is also relatively longer. Therefore, there is limitation in use of these techniques for the purpose of triage in a short time in case of emergency situation relating large number of persons. Electronic paramagnetic resonance (EPR) technique is based on the signal from unpaired electrons such as free radicals in irradiated materials especially tooth enamel, however it has also limitation for the purpose of triage because of difficulty of sample taking and its high MDD. Recently as physical methods, thermoluminescence (TL) and optically stimulated luminescence (OSL) technique have been attracted due to its lower MDD and simplicity of sample preparation. Density of the trapped charges is generally proportional to the radiation dose absorbed and the intensity of emitting light is also proportional to the density of trapped charges, thus it can be applied to measure radiation dose retrospectively. In this presentation, TL and OSL techniques are going to introduced and discussed as physical methods for retrospective accident dosimetry using trapped charges especially in electronic component materials. As a tool for dose reconstruction for emergency situation, thermoluminescece and optically stimulated luminescence techniques which are based on trapped charges during exposure of material are introduced. These techniques have several advantages such as high sensitivity, fast evaluation and ease to sample collection over common biological dosimetry and EPR

  14. Mechanical properties of a modified 2 1/4 Cr-1 Mo steel for pressure vessel applications. [V-Ti-B-modified

    Energy Technology Data Exchange (ETDEWEB)

    Klueh, R.L.; Swindeman, R.W.

    1983-12-01

    Tensile and creep properties were determined on a V-Ti-B-modified 2 1/4 Cr-1 Mo steel considered to be a candidate alloy for pressure vessel aplications for coal liquefaction. The modified 2 1/4 Cr-1 Mo steel had about 0.2% V added for improved elevated-temperature strength and 0.02% Ti for grain refinement. Boron was added to improve the hardenability, thus allowing thicker sections to be quenched and normalized to completely bainitic microstructures. Lower carbon and silicon concentrations were used (approx. 0.1% C and 0.02% Si) than in standard 2 1/4 Cr-1 Mo steel. The mechanical properties determined on the modified steel after a heat treatment typical for SA-387, grade 22, class 2, indicated high toughness and excellent elecated-temperature tensile and creep strength. The modified steel had substantially better stress-rupture properties than did a standard 2 1/4 Cr-1 Mo steel (both with bainitic microstructures) with equivalent tensile properties - especially at the lowest stresses and highest temperatures. The modified steel had toughness properties superior to those of the standard 2 1/4 Cr-1 Mo steel. Comparative transmission electron microscopy studies of the standard and modified 2 1/4 Cr-1 Mo steels indicated that the differences involve the carbide precipitates and the dislocation substructures present in the steels.

  15. Application of the base catalyzed decomposition process to treatment of PCB-contaminated insulation and other materials associated with US Navy vessels. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, A.J.; Zacher, A.H.; Gano, S.R.

    1996-09-01

    The BCD process was applied to dechlorination of two types of PCB-contaminated materials generated from Navy vessel decommissioning activities at Puget Sound Naval Shipyard: insulation of wool felt impregnated with PCB, and PCB-containing paint chips/debris from removal of paint from metal surfaces. The BCD process is a two-stage, low-temperature chemical dehalogenation process. In Stage 1, the materials are mixed with sodium bicarbonate and heated to 350 C. The volatilized halogenated contaminants (eg, PCBs, dioxins, furans), which are collected in a small volume of particulates and granular activated carbon, are decomposed by the liquid-phase reaction (Stage 2) in a stirred-tank reactor, using a high-boiling-point hydrocarbon oil as the reaction medium, with addition of a hydrogen donor, a base (NaOH), and a catalyst. The tests showed that treating wool felt insulation and paint chip wastes with Stage 2 on a large scale is feasible, but compared with current disposal costs for PCB-contaminated materials, using Stage 2 would not be economical at this time. For paint chips generated from shot/sand blasting, the solid-phase BCD process (Stage 1) should be considered, if paint removal activities are accelerated in the future.

  16. Eurados trial performance test for photon dosimetry

    DEFF Research Database (Denmark)

    Stadtmann, H.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    Within the framework of the EURADOS Action entitled Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation, trial performance tests for whole-body and extremity personal dosemeters were carried out. Photon, beta and neutron dosemeters were considered...... 312 single results, 26 fell outside the limits of the trumpet curve and 32 were outside the range 1/1.5 to 1.5. Most outliers resulted from high energy R-F irradiations without electronic equilibrium. These fields are not routinely encountered by many of the participating dosimetry services...

  17. Characterization of brazilian wollastonite for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.N. [Departamento de Fisica, Universidade Federal de Sergipe, Sao Cristovao/SE (Brazil); Melo, A.P.; Gazano, V.S.O.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. e-mail: dnsouza@fisca.ufs.br

    2006-07-01

    In these work preliminary results of the characterization analyses of Brazilian Wollastonite for radiation dosimetry are presented. Wollastonite is a silicate of calcium, Ca(SiO{sub 3}), and it was acquired in the form of rude mineral with Andradite inclusions. The sample was cleaned and prepared for obtained selected grains of Wollastonite. The analyses of chemical and mineralogical compositions were obtained using the neutron activation and X-ray powder diffraction techniques. The thermoluminescent (TL) glow curve of the material shows a prominent peak at about 200 C. TL emission spectra, and photoinduced emission spectra were also obtained. (Author)

  18. Micro dosimetry model. An extended version

    Energy Technology Data Exchange (ETDEWEB)

    Vroegindewey, C.

    1994-07-01

    In an earlier study a relative simple mathematical model has been constructed to simulate the energy transfer on a cellular scale and thus gain insight in the fundamental processes of BNCT. Based on this work, a more realistic micro dosimetry model is developed. The new facets of the model are: the treatment of proton recoil, the calculation of the distribution of energy depositions, and the determination of the number of particles crossing the target nucleus subdivided in place of origin. Besides these extensions, new stopping power tables for the emitted particles are generated and biased Monte Carlo techniques are used to reduce computer time. (orig.).

  19. Neutron spectrometry and dosimetry with ANNs

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Hernandez D, V. M. [Unidad Academica de Estudios Nucleares, Universidad Autonoma de Zacatecas, Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Departamento de Ingenieria Nuclear, Universidad Politecnica de Madrid, Jose Gutierrez Abascal 2, 28006 Madrid (Spain)], e-mail: fermineutron@yahoo.com

    2009-10-15

    Artificial neural networks technology has been applied to unfold the neutron spectra and to calculate the effective dose, the ambient equivalent dose, and the personal dose equivalent for {sup 252}Cf and {sup 241}AmBe neutron sources. A Bonner sphere spectrometry with a {sup 6}LiI(Eu) scintillator was utilized to measure the count rates of the spheres that were utilized as input in two artificial neural networks, one for spectrometry and another for dosimetry. Spectra and the ambient dose equivalent were also obtained with BUNKIUT code and the UTA4 response matrix. With both procedures spectra and ambient dose equivalent agrees in less than 10%. (author)

  20. Evaluation of an aSi-EPID with flattening filter free beams: applicability to the GLAaS algorithm for portal dosimetry and first experience for pretreatment QA of RapidArc.

    Science.gov (United States)

    Nicolini, G; Clivio, A; Vanetti, E; Krauss, H; Fenoglietto, P; Cozzi, L; Fogliata, A

    2013-11-01

    To demonstrate the feasibility of portal dosimetry with an amorphous silicon mega voltage imager for flattening filter free (FFF) photon beams by means of the GLAaS methodology and to validate it for pretreatment quality assurance of volumetric modulated arc therapy (RapidArc). The GLAaS algorithm, developed for flattened beams, was applied to FFF beams of nominal energy of 6 and 10 MV generated by a Varian TrueBeam (TB). The amorphous silicon electronic portal imager [named mega voltage imager (MVI) on TB] was used to generate integrated images that were converted into matrices of absorbed dose to water. To enable GLAaS use under the increased dose-per-pulse and dose-rate conditions of the FFF beams, new operational source-detector-distance (SDD) was identified to solve detector saturation issues. Empirical corrections were defined to account for the shape of the profiles of the FFF beams to expand the original methodology of beam profile and arm backscattering correction. GLAaS for FFF beams was validated on pretreatment verification of RapidArc plans for three different TB linacs. In addition, the first pretreatment results from clinical experience on 74 arcs were reported in terms of γ analysis. MVI saturates at 100 cm SDD for FFF beams but this can be avoided if images are acquired at 150 cm for all nominal dose rates of FFF beams. Rotational stability of the gantry-imager system was tested and resulted in a minimal apparent imager displacement during rotation of 0.2 ± 0.2 mm at SDD = 150 cm. The accuracy of this approach was tested with three different Varian TrueBeam linacs from different institutes. Data were stratified per energy and machine and showed no dependence with beam quality and MLC model. The results from clinical pretreatment quality assurance, provided a gamma agreement index (GAI) in the field area for six and ten FFF beams of (99.8 ± 0.3)% and (99.5 ± 0.6)% with distance to agreement and dose difference criteria set to 3 mm/3% with 2 mm/2

  1. Fourier transform infrared microspectroscopy and multivariate methods for radiobiological dosimetry.

    Science.gov (United States)

    Meade, A D; Clarke, C; Byrne, H J; Lyng, F M

    2010-02-01

    The scientific literature contains an ever-growing number of reports of applications of vibrational spectroscopy as a multivariate non-invasive tool for analysis of biological effects at the molecular level. Recently, Fourier transform infrared microspectroscopy (FTIRM) has been demonstrated to be sensitive to molecular events occurring in cells and tissue after exposure to ionizing radiation. In this work the application of FTIRM in the examination of dose-dependent molecular effects occurring in skin cells after exposure to ionizing radiation with the use of partial least-squares regression (PLSR) and generalized regression neural networks (GRNN) was studied. The methodology is shown to be sensitive to molecular events occurring with radiation dose and time after exposure. The variation in molecular species with dose and time after irradiation is shown to be non-linear by virtue of the higher modeling efficiency yielded from the non-linear algorithms. Dose prediction efficiencies of approximately +/-10 mGy were achieved at 96 h after irradiation, highlighting the potential applications of the methodology in radiobiological dosimetry.

  2. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hubner, S., E-mail: stephan.huebner@helmholtz-muenchen.de [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, D-80219, Munich (Georgia)

    2014-08-15

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  3. Innovations and technical-economic aspects of structural and non-structural applications of composite materials on large passenger vessels and merchant ships.

    OpenAIRE

    Maccari, A; Farolfi, F

    1992-01-01

    Considerable interest is presently being shown in research, design and practical application of composite materials within Fincantieri Merchant Shipbuilding Division. This paper is intended to discuss the state-of-the-art and the innovations in hull, outfitting and accommodation applications, where traditional steel or light alloy can be successfully replaced by composites. The impact on design and production is outlined, with an overview of the economic effects of these materials on technolo...

  4. Validation of the performance of a practical blood vessel imaging system to facilitate vessel punctures

    Science.gov (United States)

    Cuper, Natascha J.; Verdaasdonk, Rudolf M.; de Roode, Rowland

    2009-02-01

    A practical system to visualize vessels underneath the skin has been developed, based on near-infrared (NIR) transillumination. A study in the clinical setting proved the system to be useful as a support in blood withdrawal in young children. During clinical application it was found that performance varied depending on vessel size, depth of vessels and surrounding lighting conditions. To gain more insight on the different variables that determine functioning of the system, we performed phantom studies. A combined liquid/solid phantom was fabricated with similar optical properties as the tissue layers of skin reported in literature at 850 nm. This phantom was used to estimate the depth of visibility in the relation to vessel size and darkness of the skin. Vessel contrast was determined analytically from images and evaluated by 3 independent observers. The knowledge gained from these experiments will be helpful to improve the imaging system and develop a solid phantom to be used as a gold standard to test the system under various clinical lighting conditions. The working range of the system was found to be appropriate to visualize the vessels used for the most procedures, such as blood withdrawal and placement of intravenous lines.

  5. Vessel Traffic Services.

    Science.gov (United States)

    1982-12-01

    Yorker" articles titled Silent Spring by Rachel Carson in 1963 produced a unifying effect, "the sort of rallying point of the movement to protect the...6232, 92d Cong., 1st. sess., 1971, p. 2. 15. Carson , Rachel L. , The Sea Around Us, New York: Oxford Univesity Press, 195-, p. IV. 16. U.S., Congress...Government Printing Office, 1974. 63. Buhler, L. and Geiger, J., Vessel Traffic Data Extraction MethodoloqX, Silver Spring , Maryland, O6erFae-tns

  6. Vanishing corneal vessels

    Science.gov (United States)

    Nicholson, Luke; Chana, Rupinder

    2013-01-01

    We wish to highlight the importance of acknowledging the accompanying effects of topical phenylephrine drops on the eye other than its intended mydriasis. We reported a case of a 92-year-old woman with a corneal graft who was noted to have superficial corneal vascularisation which was not documented previously. After the instillation of topical tropicamide 1% and phenylephrine 2.5%, for funduscopy, the corneal vascularisation was not visible. When reassessed on another visit, tropicamide had no effect on the vessels and only phenylephrine did. We wish to highlight that when reviewing patients in cornea clinics, instilling phenylephrine prior to being seen may mask important corneal vascularisation. PMID:24121816

  7. DRDC Ottawa working standard for biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Segura, T.M.; Prud' homme-Lalonde, L. [Defence Research and Development Canada, Ottawa, Ontario (Canada); Thorleifson, E. [Health Canada, Gatineau, Quebec (Canada); Lachapelle, S.; Mullins, D. [JERA Consulting (Canada); Qutob, S. [Health Canada, Gatineau, Quebec (Canada); Wilkinson, D.

    2005-07-15

    This Standard provides quality assurance, quality control, and evaluation of the performance criteria for the purpose of accreditation of the Radiation Biology laboratory at Defence Research and Development Canada - Ottawa (DRDC Ottawa) using biological dosimetry to predict radiation exposure doses. The International Standard (ISO 19238) and the International Atomic Energy Association (IAEA) Technical Report Series No. 405 are used as guiding documents in preparation of this working document specific to the DRDC Ottawa Radiation Biology Laboratory. This Standard addresses: 1. The confidentiality of personal information, for the customer and the service laboratory; 2. The laboratory safety requirements; 3. The calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves allowing the dose estimation from chromosome aberration frequency, and the minimum detection levels; 4. Transportation criteria for shipping of test samples to the laboratory; 5. Preparation of samples for analysis; 6. The scoring procedure for unstable chromosome aberrations used for biological dosimetry; 7. The criteria for converting a measured aberration frequency into an estimate of absorbed dose; 8. The reporting of results; 9. The quality assurance and quality control plan for the laboratory; and 10. Informative annexes containing examples of a questionnaire, instructions for customers, a data sheet for recording aberrations, a sample report and other supportive documents. (author)

  8. Dosimetry methods in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D. [Universita degli Studi di Milano, Department of Physics, Via Festa del Patrono 7, 20122 Milano (Italy); Agosteo, S.; Barcaglioni, L. [Istituto Nazionale di Fisica Nucleare, Milano (Italy); Campi, F.; Garlati, L. [Politecnico di Milano, Energy Department, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); De Errico, F. [Universita degli Studi di Pisa, Department of Civil and Industrial Engineering, Lungamo Pacinotti 43, 56126 Pisa (Italy); Borroni, M.; Carrara, M. [Fondazione IRCCS Istituto Nazionale Tumori, Medical Physics Unit, Via Venezian 1, 20133 Milano (Italy); Burian, J.; Klupak, V.; Viererbl, L.; Marek, M. [Research Centre Rez, Department of Neutron Physics, 250-68 Husinec-Rez (Czech Republic)

    2014-08-15

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  9. Effect of processor temperature on film dosimetry.

    Science.gov (United States)

    Srivastava, Shiv P; Das, Indra J

    2012-01-01

    Optical density (OD) of a radiographic film plays an important role in radiation dosimetry, which depends on various parameters, including beam energy, depth, field size, film batch, dose, dose rate, air film interface, postexposure processing time, and temperature of the processor. Most of these parameters have been studied for Kodak XV and extended dose range (EDR) films used in radiation oncology. There is very limited information on processor temperature, which is investigated in this study. Multiple XV and EDR films were exposed in the reference condition (d(max.), 10 × 10 cm(2), 100 cm) to a given dose. An automatic film processor (X-Omat 5000) was used for processing films. The temperature of the processor was adjusted manually with increasing temperature. At each temperature, a set of films was processed to evaluate OD at a given dose. For both films, OD is a linear function of processor temperature in the range of 29.4-40.6°C (85-105°F) for various dose ranges. The changes in processor temperature are directly related to the dose by a quadratic function. A simple linear equation is provided for the changes in OD vs. processor temperature, which could be used for correcting dose in radiation dosimetry when film is used. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  10. Eleventh DOE workshop on personnel neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    1991-12-31

    Since its formation, the Office of Health (EH-40) has stressed the importance of the exchange of information related to and improvements in neutron dosimetry. This Workshop was the eleventh in the series sponsored by the Department of Energy (DOE). It provided a forum for operational personnel at DOE facilities to discuss current issues related to neutron dosimetry and for leading investigators in the field to discuss promising approaches for future research. A total of 26 papers were presented including the keynote address by Dr. Warren K. Sinclair, who spoke on, ``The 1990 Recommendations of the ICRP and their Biological Background.`` The first several papers discussed difficulties in measuring neutrons of different energies and ways of compensating or deriving correction factors at individual facilities. Presentations were also given by the US Navy and Air Force. Current research in neutron dosimeter development was the subject of the largest number of papers. These included a number on the development of neutron spectrometers. Selected papers were processed separately for inclusion in the Energy Science and Technology Database.

  11. Effects of the interruption of the irradiation process on PMMA Harwell Industry Dosimetry Systems

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo S.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Nowadays, the use of dyed-polymethylmethacrylate dosimetry systems in measurements at industrial irradiations has been broadly, despite the use of alanine dosimeters. Accurate dosimetry measurements are essential for the sterilization applications of medical products as well as the preservation of food by ionizing radiation. Regulations in many countries require in-plant dosimetry to ensure that the specified radiation dose has been delivered to the product. Harwell commercial dosimeters commonly are built to work with measurements between 1 kGy to 50 kGy, this means that a same dosimeter could be used until reach these values. Radiation processing demands partial measurements of the absorbed dose to guarantee the final desired applied absorbed dose depending to the dose rate. In this sense, the total absorbed dose corresponds to the cumulative partial values. In this study, several dosimeters were irradiated at the Multipurpose Gamma Irradiation Facility at IPEN - CNEN/SP to evaluate the response to the interruption of the irradiation process in the total cumulative absorbed dose values considering statistical changes and some processing parameters. When studied the Harwell dyed-polymethylmethacrylate dosimeters Red 4034 and Amber 3042, applying processing interruptions, results shown a coefficient of variation under 7% for industrial irradiation conditions to the total cumulative absorbed dose. (author)

  12. New developed cylindrical TM010 mode EPR cavity for X-band in vivo tooth dosimetry.

    Directory of Open Access Journals (Sweden)

    Guo Junwang

    Full Text Available EPR tooth in vivo dosimetry is an attractive approach for initial triage after unexpected nuclear events. An X-band cylindrical TM010 mode resonant cavity was developed for in vivo tooth dosimetry and used in EPR applications for the first time. The cavity had a trapezoidal measuring aperture at the exact position of the cavity's cylindrical wall where strong microwave magnetic field H1 concentrated and weak microwave electric field E1 distributed. Theoretical calculations and simulations were used to design and optimize the cavity parameters. The cavity features were evaluated by measuring DPPH sample, intact incisor samples embed in a gum model and the rhesus monkey teeth. The results showed that the cavity worked at designed frequency and had the ability to make EPR spectroscopy in relative high sensitivity. Sufficient modulation amplitude and microwave power could be applied into the aperture. Radiation induced EPR signal could be observed remarkably from 1 Gy irradiated intact incisor within only 30 seconds, which was among the best in scan time and detection limit. The in vivo spectroscopy was also realized by acquiring the radiation induced EPR signal from teeth of rhesus monkey whose teeth was irradiated by dose of 2 Gy. The results suggested that the cavity was sensitive to meet the demand to assess doses of significant level in short time. This cavity provided a very potential option for the development of X-band in vivo dosimetry.

  13. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2009-08-28

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document.

  14. Low-frequency electrical dosimetry: research agenda of the IEEE International Committee on Electromagnetic Safety.

    Science.gov (United States)

    Reilly, J Patrick; Hirata, Akimasa

    2016-06-21

    This article treats unsettled issues in the use of numerical models of electrical dosimetry as applied to international limits on human exposure to low-frequency (typically  IEEE-ICES (International Committee on Electromagnetic Safety) Technical Committee 95. The paper discusses 25 issues needing attention, fitting into three general categories: induction models; electrostimulation models; and human exposure limits. Of these, 9 were voted as 'high priority' by members of Subcommittee 6. The list is presented as a research agenda for refinements in numerical modeling with applications to human exposure limits. It is likely that such issues are also important in medical and electrical product safety design applications.

  15. Pulse-resolved radiotherapy dosimetry using fiber-coupled organic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Ravnsborg Beierholm, A.

    2011-05-15

    This PhD project pertains to the development and adaptation of a dosimetry system that can be used to verify the delivery of radiation in modern radiotherapy modalities involving small radiation fields and dynamic radiation delivery. The dosimetry system is based on fibre-coupled organic scintillators and can be perceived as a well characterized, independent alternative to the methods that are in clinical use today. The dosimeter itself does not require a voltage supply, and is composed of water equivalent materials. The dosimeter can be fabricated with a sensitive volume smaller than a cubic millimeter, which is small enough to resolve the small radiation fields encountered in modern radiotherapy. The fast readout of the dosimeter enables measurements on the same time scale as the pulsed radiation delivery from the medical linear accelerators used for treatment. The dosimetry system, comprising fiber-coupled organic scintillators and data acquisition hardware, was developed at the Radiation Research Division at Risoe DTU and tested using clinical x-ray beams at hospitals in Denmark and abroad. Measurements of output factors and percentage depth dose were performed and compared with reference values and Monte Carlo simulations for static square radiation fields for standard (4 cm x 4 cm to 20 cm x 20 cm) and small (down to 0.6 cm x 0.6 cm) field sizes. The accuracy of most of the obtained measurements was good, agreeing with reference and simulated dose values to within 2 % standard deviation for both standard and small fields. This thesis concludes that the new pulse-resolved dosimetry system holds great potential for modern radiotherapy applications, such as stereotactic radiotherapy and intensity-modulated radiotherapy. (Author)

  16. Evaluation of dosimetric uncertainties and transit dosimetry feasibility in pulmonary stereotactic body radiotherapy (SBRT)

    Science.gov (United States)

    Hsu, Shu-Hui

    The aims of this dissertation were to develop a method with improved accuracy for various heterogeneous geometries and to evaluate the feasibility of using EPID transit dosimetry for error detection. This dissertation examined phantom geometries with an emphasis on a tumor-in-lung geometry that may occur in hypo-fractionated SBRT treatments. For dose investigation in heterogeneous geometries, a multi-planar film measurement system was used with a measurement accuracy (within 3%) by using specific procedures to reduce the film perturbation in a low density medium. Measurements were used to validate a Monte Carlo (MC) method, and the results indicated that this MC method can be used as a reference to validate other calculation algorithms or to evaluate the doses delivered to patients for lung treatment. For developing an error detection method, a commercial electronic portal imaging device (EPID) composed of amorphous silicon was characterized for dosimetry application. A general calibration method was explored to use this device as a water-equivalent dosimeter, allowing for direct comparison to calculated doses from treatment planning systems. The calibration method was validated for a range of situations, field shapes, and intensities. The EPID transit dosimetry was sensitive to delivery errors, such as variations in treatment field shape, machine output and patient setup. The correlation between in-patient and transit dose variations may be established and used to determine acceptance or rejection criteria when the error is found. This dissertation showed the potential of using EPID dosimetry during treatment for on-line error correction and for estimating the in-patient dose error.

  17. Physical, morphological and dosimetric characterization of the Teflon agglutinator to thermoluminescent dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    D' Amorim, R.A.P.O., E-mail: raquelalinepe@gmail.com [Departamento de Física-CCET, Universidade Federal de Sergipe, 49100-000 São Cristóvão, SE (Brazil); Teixeira, M.I., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energéticas e Nucleares-IPEN-CNEN/SP, Av. Professor Lineu Prestes, 2242, 05508-000 São Paulo (Brazil); Caldas, L.V.E., E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energéticas e Nucleares-IPEN-CNEN/SP, Av. Professor Lineu Prestes, 2242, 05508-000 São Paulo (Brazil); Souza, S.O., E-mail: susanasouzalalic@gmail.com [Departamento de Física-CCET, Universidade Federal de Sergipe, 49100-000 São Cristóvão, SE (Brazil)

    2013-04-15

    In preparing of thermoluminescent dosimeters (TLD) it is common to use as agglutinator the polytetrafluoroethylene (PTFE), called Teflon{sup ®}. In this paper the physical, morphological and dosimetric characteristics of Teflon{sup ®} were evaluated aiming its application in thermoluminescent dosimetry. The differential thermal analysis (DTA) and thermogravimetry (TG) results showed that the Teflon glass transition and melting points are of about 48 °C and 340 °C, respectively. By means of the X-ray diffraction technique, the crystallinity index K{sub c} was estimated as 94%. Micrographs of Scanning Electron Microscopy (SEM) showed a cohesive surface in spodumene–Teflon pellets, as required for thermoluminescent dosimeters (TLD), leading to the conclusion that Teflon acts as binder, providing greater mechanical resistance to the TL pellets. However, Teflon may influence high doses dosimetry when it is applied as an agglutinator. Preliminary results of Teflon pellets dosimetric properties, with their dose–response curve between 50 Gy and 60 kGy, TL response reproducibility and minimum detectable dose, indicate the possibility of use of pure Teflon TLD in high-dose dosimetry. -- Highlights: ► Pure Teflon{sup ®} pellets can be exploited for high-dose dosimetry. ► Pure Teflon{sup ®} pellets showed two TL peaks. ► Low dose limits of Teflon{sup ®} pellets were 7.0 and 4.0 Gy for the first and second TL peaks respectively. ► The reproducibility of TL response of Teflon{sup ®} pellets is 2.9%.

  18. 46 CFR 289.2 - Vessels included.

    Science.gov (United States)

    2010-10-01

    ... CONSTRUCTION-DIFFERENTIAL SUBSIDY VESSELS, OPERATING-DIFFERENTIAL SUBSIDY VESSELS AND OF VESSELS SOLD OR ADJUSTED UNDER THE MERCHANT SHIP SALES ACT 1946 § 289.2 Vessels included. Vessels subject to the provisions of this part are: (a) All vessels which may in the future be constructed or sold with construction...

  19. Radiation Dosimetry for Quality Control of Food Preservation and Disinfestation

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, Arne; Uribe, R.M.

    1983-01-01

    In the use of x and gamma rays and scanned electron beams to extend the shelf life of food by delay of sprouting and ripening, killing of microbes, and control of insect population, quality assurance is provided by standardized radiation dosimetry. By strategic placement of calibrated dosimeters...... speed) to meet changes that occur in product and source parameters (e.g. bulk density and radiation spectrum). Routine dosimetry methods and certain corrections of dosimetry data may be selected for the radiations used in typical food processes....

  20. Blood flow reprograms lymphatic vessels to blood vessels.

    Science.gov (United States)

    Chen, Chiu-Yu; Bertozzi, Cara; Zou, Zhiying; Yuan, Lijun; Lee, John S; Lu, MinMin; Stachelek, Stan J; Srinivasan, Sathish; Guo, Lili; Vicente, Andres; Vincente, Andres; Mericko, Patricia; Levy, Robert J; Makinen, Taija; Oliver, Guillermo; Kahn, Mark L

    2012-06-01

    Human vascular malformations cause disease as a result of changes in blood flow and vascular hemodynamic forces. Although the genetic mutations that underlie the formation of many human vascular malformations are known, the extent to which abnormal blood flow can subsequently influence the vascular genetic program and natural history is not. Loss of the SH2 domain-containing leukocyte protein of 76 kDa (SLP76) resulted in a vascular malformation that directed blood flow through mesenteric lymphatic vessels after birth in mice. Mesenteric vessels in the position of the congenital lymphatic in mature Slp76-null mice lacked lymphatic identity and expressed a marker of blood vessel identity. Genetic lineage tracing demonstrated that this change in vessel identity was the result of lymphatic endothelial cell reprogramming rather than replacement by blood endothelial cells. Exposure of lymphatic vessels to blood in the absence of significant flow did not alter vessel identity in vivo, but lymphatic endothelial cells exposed to similar levels of shear stress ex vivo rapidly lost expression of PROX1, a lymphatic fate-specifying transcription factor. These findings reveal that blood flow can convert lymphatic vessels to blood vessels, demonstrating that hemodynamic forces may reprogram endothelial and vessel identity in cardiovascular diseases associated with abnormal flow.

  1. 46 CFR 2.01-10 - Inspection requirements-domestic vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Inspection requirements-domestic vessels. 2.01-10 Section 2.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC VESSEL INSPECTIONS Inspecting and Certificating of Vessels § 2.01-10 Inspection requirements—domestic...

  2. Chernobyl Experience in Field of Retrospective Dosimetry: Reconstruction of Doses to the Population and Liquidators Involved in the Accident (invited paper)

    Energy Technology Data Exchange (ETDEWEB)

    Chumak, V.; Likhtarev, I.; Shalom, S.; Meckbach, R.; Krjuchkov, V

    1998-07-01

    Evacuees from the 30 km zone and liquidators are likely to have received the highest Chernobyl exposures. Doses to the majority of them remained unknown, calling for dose reconstruction. This need prompted development of new techniques of retrospective dosimetry. Application of state-of-art stochastic dosimetric models and determination of site-specific location factors allowed the determination of individual doses and uncertainty ranges for a significant part of the evacuated population. A number of approaches were used to recover existing gaps in dosimetric information related to liquidators. EPR dosimetry with teeth is useful for high precision retrospective dosimetry of liquidators; now teeth from liquidators are being collected systematically in Ukraine. Analytical dose reconstruction was conducted for about 2000 Chernobyl workers. Reconstruction of doses to the rest of the liquidators requires application of a different methodology based on analysis of regularities of exposure and assignment of dose intervals according to attributes of the liquidators. (author)

  3. Characterization of Al{sub 2}O{sub 3}:C dosemeters for photon dosimetry using OSL technique; Caracterizacao de dosimetros de Al{sub 2}O{sub 3}:C para dosimetria de fotons utilizando a tecnica OSL

    Energy Technology Data Exchange (ETDEWEB)

    Villani, D.; Almeida, S.B.; Campos, L.L., E-mail: dvillani@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2016-07-01

    The optically stimulated dosimetry (OSL) has gained prominence in clinical and academic applications in Brazil. In this paper, we present results of the characterization OSL dosimeters Al{sub 2}O{sub 3}:C (TLD-500) manufactured by Rexon™ Components and TLD Systems in a RISØ reader, model TL/OSL-DA-20 for dosimetry of high-energy photon beams. All reader parameters, and its variations were evaluated. (author)

  4. Boundary Electron and Beta Dosimetry-Quantification of the Effects of Dissimilar Media on Absorbed Dose

    Science.gov (United States)

    Nunes, Josane C.

    1991-02-01

    This work quantifies the changes effected in electron absorbed dose to a soft-tissue equivalent medium when part of this medium is replaced by a material that is not soft -tissue equivalent. That is, heterogeneous dosimetry is addressed. Radionuclides which emit beta particles are the electron sources of primary interest. They are used in brachytherapy and in nuclear medicine: for example, beta -ray applicators made with strontium-90 are employed in certain ophthalmic treatments and iodine-131 is used to test thyroid function. More recent medical procedures under development and which involve beta radionuclides include radioimmunotherapy and radiation synovectomy; the first is a cancer modality and the second deals with the treatment of rheumatoid arthritis. In addition, the possibility of skin surface contamination exists whenever there is handling of radioactive material. Determination of absorbed doses in the examples of the preceding paragraph requires considering boundaries of interfaces. Whilst the Monte Carlo method can be applied to boundary calculations, for routine work such as in clinical situations, or in other circumstances where doses need to be determined quickly, analytical dosimetry would be invaluable. Unfortunately, few analytical methods for boundary beta dosimetry exist. Furthermore, the accuracy of results from both Monte Carlo and analytical methods has to be assessed. Although restricted to one radionuclide, phosphorus -32, the experimental data obtained in this work serve several purposes, one of which is to provide standards against which calculated results can be tested. The experimental data also contribute to the relatively sparse set of published boundary dosimetry data. At the same time, they may be useful in developing analytical boundary dosimetry methodology. The first application of the experimental data is demonstrated. Results from two Monte Carlo codes and two analytical methods, which were developed elsewhere, are compared

  5. A nephron-based model of the kidneys for macro-to-micro α-particle dosimetry

    Science.gov (United States)

    Hobbs, Robert F.; Song, Hong; Huso, David L.; Sundel, Margaret H.; Sgouros, George

    2012-07-01

    Targeted α-particle therapy is a promising treatment modality for cancer. Due to the short path-length of α-particles, the potential efficacy and toxicity of these agents is best evaluated by microscale dosimetry calculations instead of whole-organ, absorbed fraction-based dosimetry. Yet time-integrated activity (TIA), the necessary input for dosimetry, can still only be quantified reliably at the organ or macroscopic level. We describe a nephron- and cellular-based kidney dosimetry model for α-particle radiopharmaceutical therapy, more suited to the short range and high linear energy transfer of α-particle emitters, which takes as input kidney or cortex TIA and through a macro to micro model-based methodology assigns TIA to micro-level kidney substructures. We apply a geometrical model to provide nephron-level S-values for a range of isotopes allowing for pre-clinical and clinical applications according to the medical internal radiation dosimetry (MIRD) schema. We assume that the relationship between whole-organ TIA and TIA apportioned to microscale substructures as measured in an appropriate pre-clinical mammalian model also applies to the human. In both, the pre-clinical and the human model, microscale substructures are described as a collection of simple geometrical shapes akin to those used in the Cristy-Eckerman phantoms for normal organs. Anatomical parameters are taken from the literature for a human model, while murine parameters are measured ex vivo. The murine histological slides also provide the data for volume of occupancy of the different compartments of the nephron in the kidney: glomerulus versus proximal tubule versus distal tubule. Monte Carlo simulations are run with activity placed in the different nephron compartments for several α-particle emitters currently under investigation in radiopharmaceutical therapy. The S-values were calculated for the α-emitters and their descendants between the different nephron compartments for both the

  6. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  7. Permanent Breast Seed Implant Dosimetry Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Brian M., E-mail: Brian.Keller@sunnybrook.ca [Department of Medical Physics, Sunnybrook Health Sciences Center, Toronto, ON (Canada); Department of Radiation Oncology, University of Toronto, Sunnybrook Health Sciences Center, Toronto, ON (Canada); Ravi, Ananth [Department of Medical Physics, Sunnybrook Health Sciences Center, Toronto, ON (Canada); Sankreacha, Raxa [Carlo Fidani Regional Cancer Center, Mississauga, ON (Canada); Pignol, Jean-Philippe [Department of Radiation Oncology, University of Toronto, Sunnybrook Health Sciences Center, Toronto, ON (Canada)

    2012-05-01

    Purpose: A permanent breast seed implant is a novel method of accelerated partial breast irradiation for women with early-stage breast cancer. This article presents pre- and post-implant dosimetric data, relates these data to clinical outcomes, and makes recommendations for those interested in starting a program. Methods and Materials: A total of 95 consecutive patients were accrued into one of three clinical trials after breast-conserving surgery: a Phase I/II trial (67 patients with infiltrating ductal carcinoma); a Phase II registry trial (25 patients with infiltrating ductal carcinoma); or a multi-center Phase II trial for patients with ductal carcinoma in situ (3 patients). Contouring of the planning target volume (PTV) was done on a Pinnacle workstation and dosimetry calculations, including dose-volume histograms, were done using a Variseed planning computer. Results: The mean pre-implant PTV coverage for the V{sub 90}, V{sub 100}, V{sub 150}, and V{sub 200} were as follows: 98.8% {+-} 1.2% (range, 94.5-100%); 97.3% {+-} 2.1% (range, 90.3-99.9%), 68.8% {+-} 14.3% (range, 32.7-91.5%); and 27.8% {+-} 8.6% (range, 15.1-62.3%). The effect of seed motion was characterized by post-implant dosimetry performed immediately after the implantation (same day) and at 2 months after the implantation. The mean V{sub 100} changed from 85.6% to 88.4% (p = 0.004) and the mean V{sub 200} changed from 36.2% to 48.3% (p < 0.001). Skin toxicity was associated with maximum skin dose (p = 0.014). Conclusions: Preplanning dosimetry should aim for a V{sub 90} of approximately 100%, a V{sub 100} between 95% and 100%, and a V{sub 200} between 20% and 30%, as these numbers are associated with no local recurrences to date and good patient tolerance. In general, the target volume coverage improved over the duration of the seed therapy. The maximum skin dose, defined as the average dose over the hottest 1 Multiplication-Sign 1-cm{sup 2} surface area, should be limited to 90% of the

  8. [Large vessel vasculitides].

    Science.gov (United States)

    Morović-Vergles, Jadranka; Puksić, Silva; Gracanin, Ana Gudelj

    2013-01-01

    Large vessel vasculitis includes Giant cell arteritis and Takayasu arteritis. Giant cell arteritis is the most common form of vasculitis affect patients aged 50 years or over. The diagnosis should be considered in older patients who present with new onset of headache, visual disturbance, polymyalgia rheumatica and/or fever unknown cause. Glucocorticoides remain the cornerstone of therapy. Takayasu arteritis is a chronic panarteritis of the aorta ant its major branches presenting commonly in young ages. Although all large arteries can be affected, the aorta, subclavian and carotid arteries are most commonly involved. The most common symptoms included upper extremity claudication, hypertension, pain over the carotid arteries (carotidynia), dizziness and visual disturbances. Early diagnosis and treatment has improved the outcome in patients with TA.

  9. Vessel segmentation in screening mammograms

    Science.gov (United States)

    Mordang, J. J.; Karssemeijer, N.

    2015-03-01

    Blood vessels are a major cause of false positives in computer aided detection systems for the detection of breast cancer. Therefore, the purpose of this study is to construct a framework for the segmentation of blood vessels in screening mammograms. The proposed framework is based on supervised learning using a cascade classifier. This cascade classifier consists of several stages where in each stage a GentleBoost classifier is trained on Haar-like features. A total of 30 cases were included in this study. In each image, vessel pixels were annotated by selecting pixels on the centerline of the vessel, control samples were taken by annotating a region without any visible vascular structures. This resulted in a total of 31,000 pixels marked as vascular and over 4 million control pixels. After training, the classifier assigns a vesselness likelihood to the pixels. The proposed framework was compared to three other vessel enhancing methods, i) a vesselness filter, ii) a gaussian derivative filter, and iii) a tubeness filter. The methods were compared in terms of area under the receiver operating characteristics curves, the Az values. The Az value of the cascade approach is 0:85. This is superior to the vesselness, Gaussian, and tubeness methods, with Az values of 0:77, 0:81, and 0:78, respectively. From these results, it can be concluded that our proposed framework is a promising method for the detection of vessels in screening mammograms.

  10. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  11. Proceedings of the third conference on radiation protection and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Swaja, R.E.; Sims, C.S.; Casson, W.H. [eds.

    1991-10-01

    The Third Conference on Radiation Protection and Dosimetry was held during October 21--24, 1991, at the Sheraton Plaza Hotel in Orlando, Florida. This meeting was designed with the objectives of promoting communication among applied, research, regulatory, and standards personnel involved in radiation protection, and providing them with sufficient information to evaluate their programs. To meet these objectives, a technical program consisting of more than 75 invited and contributed oral presentations encompassing all aspects of radiation protection was prepared. General topics considered in the technical session included external dosimetry, internal dosimetry, instruments, accident dosimetry, regulations and standards, research advances, and applied program experience. In addition, special sessions were held to afford attendees the opportunity to make short presentations of recent work or to discuss topics of general interest. Individual reports are processed separately on the database.

  12. Clinical radionuclide therapy dosimetry: the quest for the "Holy Gray".

    NARCIS (Netherlands)

    Brans, B.; Bodei, L.; Giammarile, F.; Linden, O.; Luster, M.; Oyen, W.J.G.; Tennvall, J.

    2007-01-01

    INTRODUCTION: Radionuclide therapy has distinct similarities to, but also profound differences from external radiotherapy. REVIEW: This review discusses techniques and results of previously developed dosimetry methods in thyroid carcinoma, neuro-endocrine tumours, solid tumours and lymphoma. In each

  13. The physics of small megavoltage photon beam dosimetry.

    Science.gov (United States)

    Andreo, Pedro

    2017-11-27

    The increased interest during recent years in the use of small megavoltage photon beams in advanced radiotherapy techniques has led to the development of dosimetry recommendations by different national and international organizations. Their requirement of data suitable for the different clinical options available, regarding treatment units and dosimetry equipment, has generated a considerable amount of research by the scientific community during the last decade. The multiple publications in the field have led not only to the availability of new invaluable data, but have also contributed substantially to an improved understanding of the physics of their dosimetry. This work provides an overview of the most important aspects that govern the physics of small megavoltage photon beam dosimetry. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Image noise in X-ray CT polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hilts, M [Medical Physics, BC Cancer Agency, Vancouver Centre (Canada); Department of Physics and Astronomy, University of British Columbia, Vancouver, BC (Canada); Duzenli, C [Medical Physics, BC Cancer Agency, Vancouver Centre (Canada)

    2004-01-01

    This work investigates factors which affect image noise in CT polymer gel dosimetry, discusses techniques that can be used to further improve image noise and provides overall recommendations for the CT imaging of polymer gels.

  15. The radiation dosimetry of intrathecally administered radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Stabin, M.G. [Oak Ridge Inst. for Science and Education, TN (United States); Evans, J.F. [Ohio State Univ., Columbus, OH (United States)

    1999-01-01

    The radiation dose to the spine, spinal cord, marrow, and other organs of the body from intrathecal administration of several radiopharmaceuticals was studied. Anatomic models were developed for the spine, spinal cerebrospinal fluid (CSF), spinal cord, spinal skeleton, cranial skeleton, and cranial CSF. A kinetic model for the transport of CSF was used to determine residence times in the CSF; material leaving the CSF was thereafter assumed to enter the bloodstream and follow the kinetics of the radiopharmaceutical as if intravenously administered. The radiation transport codes MCNP and ALGAMP were used to model the electron and photon transport and energy deposition. The dosimetry of Tc-99m DTPA and HSA, In-111 DTPA, I-131 HSA, and Yb-169 DTPA was studied. Radiation dose profiles for the spinal cord and marrow in the spine were developed and average doses to all other organs were estimated, including dose distributions within the bone and marrow.

  16. Fast neutron activation dosimetry with TLDS

    Energy Technology Data Exchange (ETDEWEB)

    Pearson, D.W.; Moran, P.R.

    1975-01-01

    Fast neutron activation using threshold reactions is the only neutron dosimetry method which offers complete discrimination against gamma-rays and preserves some information about the neutron energy. Conventional activation foil technique requires sensitive radiation detectors to count the decay of the neutron induced activity. For extensive measurements at low neutron fluences, vast outlays of counting equipment are required. TL dosimeters are inexpensive, extremely sensitive radiation detectors. The work of Mayhugh et al. (Proc. Third Int. Conf. on Luminescence Dosimetry, Riso Report 249, 1040, (1971)) showed that CaSO/sub 4/: DyTLDs could be used to measure the integrated dose from the decay of the radioactivity produced in the dosimeters by exposure to thermal neutrons. This neatly combines the activation detector and counter functions in one solid state device. This work has been expanded to fast neutron exposures and other TL phosphors. The reactions /sup 19/F(n, 2n)/sup 18/F, /sup 32/S(n,p)/sup 32/P, /sup 24/Mg(n,p)/sup 24/, and /sup 64/Zn(n,p)/sup 64/Cu were found useful for fast neutron activation in commercial TLDs. As each TLD is its own integrating decay particle counter, many activation measurements can be made at the same time. The subsequent readings of the TL signals can be done serially after the induced radioactivity has decayed, using only one TL reader. The neutron detection sensitivity is limited mainly by the number statistics of the neutron activations. The precision of the neutron measurement is within a factor of two of conventional foil activation for comparable mass detectors. Commercially available TLDs can measure neutron fluences of 10/sup 9/n/cm/sup 2/ with 10 percent precision.

  17. Dosimetry of low-energy beta radiation

    Energy Technology Data Exchange (ETDEWEB)

    Borg, J.

    1996-08-01

    Useful techniques and procedures for determination of absorbed doses from exposure in a low-energy {beta} radiation field were studied and evaluated in this project. The four different techniques included were {beta} spectrometry, extrapolation chamber dosimetry, Monte Carlo (MC) calculations, and exoelectron dosimetry. As a typical low-energy {beta} radiation field a moderated spectrum from a {sup 14}C source (E{sub {beta}},{sub max} =156 keV) was chosen for the study. The measured response of a Si(Li) detector to photons (bremsstrahlung) showed fine agreement with the MC calculated photon response, whereas the difference between measured and MC calculated responses to electrons indicates an additional dead layer thickness of about 12 {mu}m in the Si(Li) detector. The depth-dose profiles measured with extrapolation chambers at two laboratories agreed very well, and it was confirmed that the fitting procedure previously reported for {sup 147}Pm depth-dose profiles is also suitable for {beta} radiation from {sup 14}C. An increasing difference between measured and MC calculated dose rates for increasing absorber thickness was found, which is explained by limitations of the EGS4 code for transport of very low-energy electrons (below 10-20 keV). Finally a study of the thermally stimulated exoelectron emission (TSEE) response of BeO thin film dosemeters to {beta} radiation for radiation fields with maximum {beta} energies ranging from 67 keV to 2.27 MeV is reported. For maximum {beta} energies below approximately 500 keV, a decrease in the response amounting to about 20% was observed. It is thus concluded that a {beta} dose higher than about 10 {mu}Gy can be measured with these dosemeters to within 0 to -20% independently of the {beta}energy for E{sub {beta}},{sub max} values down to 67 keV. (au) 12 tabs., 38 ills., 71 refs.

  18. In vivo dosimetry during tangential breast treatment.

    Science.gov (United States)

    Heukelom, S; Lanson, J H; van Tienhoven, G; Mijnheer, B J

    1991-12-01

    The 3-dimensional (3-D) dose distribution as calculated in clinical practice for tangential breast treatment was verified by means of in vivo dosimetry. Clinical practice in our institution implies the use of 8 MV X-ray beams, a 2-D treatment planning system, collimator rotation and a limited set of patient data for dose calculations. By positioning diodes at the central beam axes as well as in the periphery of the breast the magnitude of the dose values at the isocentre and in points situated in the high-dose regions behind the lung could be assessed. The position of the diodes was verified by means of an on-line portal imaging device. The reproducibility of these in vivo dose measurements was better than 2% (1 SD). Our study showed that on the average the dose delivery at the isocentre is 2% less and at the points behind the lung, 5.7% higher with respect to the calculated dose values. Detailed analysis of these in vivo dosimetry results, based on dose measurements performed with a breast shaped phantom, yielded the magnitudes of the errors in the predicted dose due to several limitations in the dose calculation algorithms and dose calculation procedure. These limitations are each introducing an error of several percent but are compensating each other for the dose calculation at the isocentre. We concluded that the dose distribution in a patient for our treatment technique and dose calculation procedure can be predicted with a 2-D treatment planning system in an acceptable way. A more accurate prediction of the dose distribution can be performed but requires an estimation of the lack of scatter due to missing tissue, the change in the dose distribution due to oblique incident beams and the incorporation of the actual output of the treatment machine in the assessment of the number of monitor units.

  19. The application of total vertical projections for the unbiased estimation of the length of blood vessels and other structures by magnetic resonance imaging.

    Science.gov (United States)

    Roberts, N; Howard, C V; Cruz-Orive, L M; Edwards, R H

    1991-01-01

    A new stereological method has recently been developed to estimate the total length of a bounded curve in 3D from a sample of projections about a vertical axis. Unlike other methods based on serial section reconstructions, the new method is unbiased (i.e., it has zero systematic error). A basic requirement, not difficult to fulfill in many cases, is that the masking of one structure by another is not appreciable. The application of the new method to real curvilinear structures using a clinical magnetic resonance (MR) imager is illustrated. The first structure measured was a twisted water-filled glass tube of known length. The accuracy of the method was assessed: With six vertical projections, the tube length was measured to within 2% of the true value. The second example was a living bonsai tree, and the third was a clinical application of MR angiography. The possibility of applying the method to other scientific disciplines, for example, the monitoring of plant root growth, is discussed.

  20. On the re-calibration process in radiochromic film dosimetry.

    Science.gov (United States)

    Ruiz-Morales, Carmen; Vera-Sánchez, Juan Antonio; González-López, Antonio

    2017-10-01

    The accuracy and precision of the dose estimates obtained with radiochromic film dosimetry are investigated in a clinical environment. The improvement in the accuracy of dose estimates reached with corrective methods is analyzed. Two novel re-calibration algorithms for radiochromic film dosimetry are presented. Two different EBT3 lots are evaluated in two different centres. They are calibrated in Varian linacs and read in two different EPSON scaners. Once the lots are calibrated, three films per lot are considered and divided into stripes that are exposed to known doses. Several dosimetry protocols usually employed in radiochromic film dosimetry are used to convert film responses to absorbed doses. These protocols are characterized by different choices of the film responses or different sensitometric curves. Finally, the accuracy and reproducibility of the dose estimates is investigated with and without the corrective methods. The variabilities that affect radiochromic film dosimetry, such as intra-lot variability, inter-scan variability, post-exposure time and film autodevelopment may give rise to inaccuracies in the dose estimates. However, the implementation of re-calibration methods leads to more accurate dose estimates. All the investigated protocols showed more accurate and reproducible results when the re-calibrated methods were employed. So, the novel re-calibration methods may be applied in order to improve the accuracy and reproducibility of radiochromic film dosimetry. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Systematic evaluation of photodetector performance for plastic scintillation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Boivin, Jonathan, E-mail: jonathan.boivin.1@ulaval.ca; Beaulieu, Luc [Département de Physique, de Génie physique et d’Optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec G1V 0A6, Canada and Département de Radio-Oncologie et Axe oncologie du Centre de recherche du CHU de Québec, CHU de Québec, Québec, Québec G1R 2J6 (Canada); Beddar, Sam [Department of Radiation Physics, University of Texas, MD Anderson Cancer Center, Houston, Texas 77030 (United States); Guillemette, Maxime [Département de Physique, de Génie physique et d’Optique, Université Laval, Québec, Québec G1V 0A6, Canada and Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, Québec G1V 4G5 (Canada)

    2015-11-15

    Purpose: The authors’ objective was to systematically assess the performance of seven photodetectors used in plastic scintillation dosimetry. The authors also propose some guidelines for selecting an appropriate detector for a specific application. Methods: The plastic scintillation detector (PSD) consisted of a 1-mm diameter, 10-mm long plastic scintillation fiber (BCF-60), which was optically coupled to a clear 10-m long optical fiber of the same diameter. A light-tight plastic sheath covered both fibers and the scintillator end was sealed. The clear fiber end was connected to one of the following photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens), a monochromatic camera with an optical lens, a PIN photodiode, an avalanche photodiode (APD), or a photomultiplier tube (PMT). A commercially available W1 PSD was also included in the study, but it relied on its own fiber and scintillator. Each PSD was exposed to both low-energy beams (120, 180, and 220 kVp) from an orthovoltage unit and high-energy beams (6 and 23 MV) from a linear accelerator. Various dose rates were tested to identify the operating range and accuracy of each photodetector. Results: For all photodetectors, the relative uncertainty was less than 5% for dose rates higher than 3 mGy/s. The cameras allowed multiple probes to be used simultaneously, but they are less sensitive to low-light signals. The PIN, APD, and PMT had higher sensitivity, making them more suitable for low dose rate and out-of-field dose monitoring. The relative uncertainty of the PMT was less than 1% at the lowest dose rate achieved (0.10 mGy/s), suggesting that it was optimal for use in live dosimetry. Conclusions: For dose rates higher than 3 mGy/s, the PIN diode is the most effective photodetector in terms of performance/cost ratio. For lower dose rates, such as those seen in interventional radiology or high-gradient radiotherapy, PMTs are the optimal choice.

  2. Systematic evaluation of photodetector performance for plastic scintillation dosimetry.

    Science.gov (United States)

    Boivin, Jonathan; Beddar, Sam; Guillemette, Maxime; Beaulieu, Luc

    2015-11-01

    The authors' objective was to systematically assess the performance of seven photodetectors used in plastic scintillation dosimetry. The authors also propose some guidelines for selecting an appropriate detector for a specific application. The plastic scintillation detector (PSD) consisted of a 1-mm diameter, 10-mm long plastic scintillation fiber (BCF-60), which was optically coupled to a clear 10-m long optical fiber of the same diameter. A light-tight plastic sheath covered both fibers and the scintillator end was sealed. The clear fiber end was connected to one of the following photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens), a monochromatic camera with an optical lens, a PIN photodiode, an avalanche photodiode (APD), or a photomultiplier tube (PMT). A commercially available W1 PSD was also included in the study, but it relied on its own fiber and scintillator. Each PSD was exposed to both low-energy beams (120, 180, and 220 kVp) from an orthovoltage unit and high-energy beams (6 and 23 MV) from a linear accelerator. Various dose rates were tested to identify the operating range and accuracy of each photodetector. For all photodetectors, the relative uncertainty was less than 5% for dose rates higher than 3 mGy/s. The cameras allowed multiple probes to be used simultaneously, but they are less sensitive to low-light signals. The PIN, APD, and PMT had higher sensitivity, making them more suitable for low dose rate and out-of-field dose monitoring. The relative uncertainty of the PMT was less than 1% at the lowest dose rate achieved (0.10 mGy/s), suggesting that it was optimal for use in live dosimetry. For dose rates higher than 3 mGy/s, the PIN diode is the most effective photodetector in terms of performance/cost ratio. For lower dose rates, such as those seen in interventional radiology or high-gradient radiotherapy, PMTs are the optimal choice.

  3. Patient-Specific Dosimetry and Radiobiological Modeling of Targeted Radionuclide Therapy Grant - final report

    Energy Technology Data Exchange (ETDEWEB)

    George Sgouros, Ph.D.

    2007-03-20

    The broad, long-term objectives of this application are to 1. develop easily implementable tools for radionuclide dosimetry that can be used to predict normal organ toxicity and tumor response in targeted radionuclide therapy; and 2. to apply these tools to the analysis of clinical trial data in order to demonstrate dose-response relationships for radionuclide therapy treatment planning. The work is founded on the hypothesis that robust dose-response relationships have not been observed in targeted radionuclide therapy studies because currently available internal dosimetry methodologies are inadequate, failing to adequately account for individual variations in patient anatomy, radionuclide activity distribution/kinetics, absorbed dose-distribution, and absorbed dose-rate. To reduce development time the previously available software package, 3D-ID, one of the first dosimetry software packages to incorporate 3-D radionuclide distribution with individual patient anatomy; and the first to be applied for the comprehensive analysis of patient data, will be used as a platform to build the functionality listed above. The following specific aims are proposed to satisfy the long-term objectives stated above: 1. develop a comprehensive and validated methodology for converting one or more SPECT images of the radionuclide distribution to a 3-D representation of the cumulated activity distribution; 2. account for differences in tissue density and atomic number by incorporating an easily implementable Monte Carlo methodology for the 3-D dosimetry calculations; 3. incorporate the biologically equivalent dose (BED) and equivalent uniform dose (EUD) models to convert the spatial distribution of absorbed dose and dose-rate into equivalent single values that account for differences in dose uniformity and rate and that may be correlated with tumor response and normal organ toxicity; 4. test the hypothesis stated above by applying the resulting package to patient trials of targeted

  4. ISDD: A computational model of particle sedimentation, diffusion and target cell dosimetry for in vitro toxicity studies

    Science.gov (United States)

    2010-01-01

    Background The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment, particularly for in vitro systems. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. μg particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes of polystyrene spheres (20-1100 nm), 35 nm amorphous silica, and large agglomerates of 30 nm iron oxide particles. Overall, without adjusting any parameters, model predicted cellular doses were in close agreement with the experimental data, differing from as little as 5% to as much as three-fold, but in most cases approximately two-fold, within the limits of the accuracy of the measurement systems. Applying the model, we generalize the effects of particle size, particle density, agglomeration state and agglomerate characteristics on target cell dosimetry in vitro. Conclusions Our results confirm our hypothesis that for liquid-based in vitro systems, the dose-rates and target cell doses for all particles are not equal; they can vary significantly, in direct contrast to the assumption of dose-equivalency implicit in the use of mass-based media concentrations as metrics of exposure for dose-response assessment. The difference between equivalent nominal media concentration exposures on a μg/mL basis and target cell

  5. ISDD: A computational model of particle sedimentation, diffusion and target cell dosimetry for in vitro toxicity studies

    Directory of Open Access Journals (Sweden)

    Chrisler William B

    2010-11-01

    Full Text Available Abstract Background The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment, particularly for in vitro systems. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. μg particle/mL culture medium, particle surface area/mL, particle number/mL. We have developed a computational model of solution particokinetics (sedimentation, diffusion and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation and the Stokes-Einstein equation (diffusion. Results The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD was tested against measured transport rates or cellular doses for multiple sizes of polystyrene spheres (20-1100 nm, 35 nm amorphous silica, and large agglomerates of 30 nm iron oxide particles. Overall, without adjusting any parameters, model predicted cellular doses were in close agreement with the experimental data, differing from as little as 5% to as much as three-fold, but in most cases approximately two-fold, within the limits of the accuracy of the measurement systems. Applying the model, we generalize the effects of particle size, particle density, agglomeration state and agglomerate characteristics on target cell dosimetry in vitro. Conclusions Our results confirm our hypothesis that for liquid-based in vitro systems, the dose-rates and target cell doses for all particles are not equal; they can vary significantly, in direct contrast to the assumption of dose-equivalency implicit in the use of mass-based media concentrations as metrics of exposure for dose-response assessment. The difference between equivalent nominal media concentration exposures on a

  6. ISDD: A Computational Model of Particle Sedimentation, Diffusion and Target Cell Dosimetry for In Vitro Toxicity Studies

    Energy Technology Data Exchange (ETDEWEB)

    Hinderliter, Paul M.; Minard, Kevin R.; Orr, Galya; Chrisler, William B.; Thrall, Brian D.; Pounds, Joel G.; Teeguarden, Justin G.

    2010-11-30

    Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. μg particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes of polystyrene spheres (20-1100 nm), 35 nm amorphous silica, and large agglomerates of 30 nm iron oxide particles. Overall, without adjusting any parameters, model predicted doses were in close agreement with the experimental data, differing from as little as 5% to as much as three-fold, but in most cases approximately two-fold, within the limits of the accuracy of the measurement systems. Applying the model, we generalize the effects of particle size, particle density, agglomeration state and agglomerate characteristics on target cell dosimetry in vitro. Conclusions: Our results confirm our hypothesis that the dose-rates for all particles are not equal, but can vary significantly, in direct contrast to the assumption of dose-equivalency implicit in the use of mass-based media concentrations as metrics of exposure for dose-response assessment. The difference between equivalent nominal media concentration exposures on a μg/mL basis and target cell doses on a particle surface area or number basis can be as high as three to six orders of magnitude

  7. Review on the characteristics of radiation detectors for dosimetry and imaging

    Science.gov (United States)

    Seco, Joao; Clasie, Ben; Partridge, Mike

    2014-10-01

    The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been transformed by the implementation of multi-slice CT and digital x-ray imaging systems, with silver halide films now largely obsolete for many applications. Nuclear medicine has benefited from more sensitive, faster and higher-resolution detectors delivering ever-higher SPECT and PET image quality. PET/MR systems have been enabled by the development of gamma ray detectors that can operate in high magnetic fields. These huge advances in imaging have enabled equally impressive steps forward in radiotherapy delivery accuracy, with 4DCT, PET and MRI routinely used in treatment planning and online image guidance provided by cone-beam CT. The challenge of ensuring safe, accurate and precise delivery of highly complex radiation fields has also both driven and benefited from advances in radiation detectors. Detector systems have been developed for the measurement of electron, intensity-modulated and modulated arc x-ray, proton and ion beams, and around brachytherapy sources based on a very wide range of technologies. The types of measurement performed are equally wide, encompassing commissioning and quality assurance, reference dosimetry, in vivo dosimetry and personal and environmental monitoring. In this article, we briefly introduce the general physical characteristics and properties that are commonly used to describe the behaviour and performance of both discrete and imaging detectors. The physical principles of operation of calorimeters; ionization and charge detectors; semiconductor, luminescent, scintillating and chemical detectors; and radiochromic and radiographic films are then reviewed and their principle applications discussed. Finally, a general

  8. Apparatus to measure low level helium for neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Shuji; Takao, Yoshiyuki; Muramasu, Masatomo; Hida, Tomoya; Sou, Hirofumi; Nakashima, Hideki [Kyushu Univ., Fukuoka (Japan); Kanda, Yukinori

    1998-03-01

    An apparatus to measure low level helium in a solid sample for neutron dosimetry in the practical use such as area monitoring in the long-term and reactor surveillance was reported. In our previous work, the helium atoms measurement system (HAMS) was developed. A sample was evaporated in the furnace and the released gas from the sample was analyzed with the mass spectrometer of the system to determine the amount of helium contained in it. The system has been improved to advance the lower helium measurement limit in a solid sample for its application to an area monitoring system. The mass of a solid is up to 100mg. Two important points should be considered to advance the lower limit. One was to produce a high quality vacuum in the system chamber for suppressing background gases during the sample measurement. The other important point was to detect very small output from the mass spectrometer. A pulse counting system was used to get high sensitivity in the mass 4 analyzing. (author)

  9. Preclinical dosimetry of magnetic fluid hyperthermia for bladder cancer

    Science.gov (United States)

    Oliveira, Tiago R.; Stauffer, Paul R.; Lee, Chen-Ting; Landon, Chelsea; Etienne, Wiguins; Maccarini, Paolo F.; Inman, Brant; Dewhirst, Mark W.

    2013-02-01

    Background Despite positive efficacy, thermotherapy is not widely used in clinical oncology. Difficulties associated with field penetration and controlling power deposition patterns in heterogeneous tissue have limited its use for heating deep in the body. Heat generation using iron-oxide super-paramagnetic nanoparticles excited with magnetic fields has been demonstrated to overcome some of these limitations. The objective of this preclinical study is to investigate the feasibility of treating bladder cancer with magnetic fluid hyperthermia (MFH) by analyzing the thermal dosimetry of nanoparticle heating in a rat bladder model. Methods The bladders of 25 female rats were injected with 0.4 ml of Actium Biosystems magnetite-based nanoparticles (Actium Biosystems, Boulder CO) via catheters inserted in the urethra. To assess the distribution of nanoparticles in the rat after injection we used the 7 T small animal MRI system (Bruker ClinScan, Bruker BioSpin MRI GmbH, Ettlingen, Germany). Heat treatments were performed with a small animal magnetic field applicator (Actium Biosystems, Boulder CO) with a goal of raising bladder temperature to 42°C in 1°C/min to a steady-state of 42°C. Conclusion Our data demonstrate that a MFH system provides well-localized heating of rat bladder with effective control of temperature in the bladder and minimal heating of surrounding tissues.

  10. On the role of exponential smoothing in circadian dosimetry.

    Science.gov (United States)

    Price, Luke L A

    2014-01-01

    The effects lighting has on health through modulation of circadian rhythms are becoming increasingly well documented. Data are still needed to show how light exposures are influenced by architecture and lighting design and circadian dosimetry analyses should provide duration, phase and amplitude measures of 24 h exposure profiles. Exponential smoothing is used to derive suitable metrics from 24 h light measurements collected from private dwellings. A further application of these modified exposure time series as physiological models of the light drive is discussed. Unlike previous light drive models, the dose rate persists into periods of darkness following exposures. Comparisons to long duration exposure studies suggest this type of persistent light drive model could be incorporated into contemporary physiological models of the human circadian oscillator. © 2014 Crown copyright. Photochemistry and Photobiology © 2014 The American Society of Photobiology. This article is published with the permission of the Controller of HMSO and the Queen's Printer for Scotland and Public Health England.

  11. Processing and analysis techniques involving in-vessel material generation

    Science.gov (United States)

    Schabron, John F [Laramie, WY; Rovani, Jr., Joseph F.

    2011-01-25

    In at least one embodiment, the inventive technology relates to in-vessel generation of a material from a solution of interest as part of a processing and/or analysis operation. Preferred embodiments of the in-vessel material generation (e.g., in-vessel solid material generation) include precipitation; in certain embodiments, analysis and/or processing of the solution of interest may include dissolution of the material, perhaps as part of a successive dissolution protocol using solvents of increasing ability to dissolve. Applications include, but are by no means limited to estimation of a coking onset and solution (e.g., oil) fractionating.

  12. An automated method for accurate vessel segmentation

    Science.gov (United States)

    Yang, Xin; Liu, Chaoyue; Le Minh, Hung; Wang, Zhiwei; Chien, Aichi; (Tim Cheng, Kwang-Ting

    2017-05-01

    Vessel segmentation is a critical task for various medical applications, such as diagnosis assistance of diabetic retinopathy, quantification of cerebral aneurysm’s growth, and guiding surgery in neurosurgical procedures. Despite technology advances in image segmentation, existing methods still suffer from low accuracy for vessel segmentation in the two challenging while common scenarios in clinical usage: (1) regions with a low signal-to-noise-ratio (SNR), and (2) at vessel boundaries disturbed by adjacent non-vessel pixels. In this paper, we present an automated system which can achieve highly accurate vessel segmentation for both 2D and 3D images even under these challenging scenarios. Three key contributions achieved by our system are: (1) a progressive contrast enhancement method to adaptively enhance contrast of challenging pixels that were otherwise indistinguishable, (2) a boundary refinement method to effectively improve segmentation accuracy at vessel borders based on Canny edge detection, and (3) a content-aware region-of-interests (ROI) adjustment method to automatically determine the locations and sizes of ROIs which contain ambiguous pixels and demand further verification. Extensive evaluation of our method is conducted on both 2D and 3D datasets. On a public 2D retinal dataset (named DRIVE (Staal 2004 IEEE Trans. Med. Imaging 23 501-9)) and our 2D clinical cerebral dataset, our approach achieves superior performance to the state-of-the-art methods including a vesselness based method (Frangi 1998 Int. Conf. on Medical Image Computing and Computer-Assisted Intervention) and an optimally oriented flux (OOF) based method (Law and Chung 2008 European Conf. on Computer Vision). An evaluation on 11 clinical 3D CTA cerebral datasets shows that our method can achieve 94% average accuracy with respect to the manual segmentation reference, which is 23% to 33% better than the five baseline methods (Yushkevich 2006 Neuroimage 31 1116-28; Law and Chung 2008

  13. 50 CFR 648.8 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 8 2010-10-01 2010-10-01 false Vessel identification. 648.8 Section 648.8... identification. (a) Vessel name and official number. Each fishing vessel subject to this part and over 25 ft (7.6... or ocean quahog vessels licensed under New Jersey law may use the appropriate vessel identification...

  14. System of data management in 'Dosis' personal dosimetry; Sistema de gestion de datos en dosimetria personal 'dosis'

    Energy Technology Data Exchange (ETDEWEB)

    Manzano de Armas, Jose; Diaz Bernal, Efren; Capote Ferrera, Eduardo; Molina Perez, Daniel; Lopez Bejerano, Gladys [Centro de Proteccion y Higiene de las Radiaciones, La Habana (Cuba)]. E-mail: manzano@cphr.edu.cu

    2001-07-01

    The storage and control of the data of a service of personal dosimetry is a task that requires specify care in data handling and manipulation. This activity becomes more annoying of making manually when the volume of users of the service is significant. The External Dosimetric Laboratory of the Center for Radiation Protection and Hygiene has developed a system of administration of data that allows the storage, control and analysis of the data generated by the Service of Personal Dosimetry in an efficient and reliable way. This paper describes the characteristics of the System for Administration of Data in Personal Dosimetry 'Dosis', as well as their design and programming. The importance of this System for the laboratory and the advantages of their application are described. The characteristics of the different modules are also described. (author)

  15. A probabilistic gastrointestinal tract dosimetry model

    Science.gov (United States)

    Huh, Chulhaeng

    In internal dosimetry, the tissues of the gastrointestinal (GI) tract represent one of the most radiosensitive organs of the body with the hematopoietic bone marrow. Endoscopic ultrasound is a unique tool to acquire in-vivo data on GI tract wall thicknesses of sufficient resolution needed in radiation dosimetry studies. Through their different echo texture and intensity, five layers of differing echo patterns for superficial mucosa, deep mucosa, submucosa, muscularis propria and serosa exist within the walls of organs composing the alimentary tract. Thicknesses for stomach mucosa ranged from 620 +/- 150 mum to 1320 +/- 80 mum (total stomach wall thicknesses from 2.56 +/- 0.12 to 4.12 +/- 0.11 mm). Measurements made for the rectal images revealed rectal mucosal thicknesses from 150 +/- 90 mum to 670 +/- 110 mum (total rectal wall thicknesses from 2.01 +/- 0.06 to 3.35 +/- 0.46 mm). The mucosa thus accounted for 28 +/- 3% and 16 +/- 6% of the total thickness of the stomach and rectal wall, respectively. Radiation transport simulations were then performed using the Monte Carlo N-particle transport code (MCNP) 4C transport code to calculate S values (Gy/Bq-s) for penetrating and nonpenetrating radiations such as photons, beta particles, conversion electrons and auger electrons of selected nuclides, I123, I131, Tc 99m and Y90 under two source conditions: content and mucosa sources, respectively. The results of this study demonstrate generally good agreement with published data for the stomach mucosa wall. The rectal mucosa data are consistently higher than published data compared with the large intestine due to different radiosensitive cell thicknesses (350 mum vs. a range spanning from 149 mum to 729 mum) and different geometry when a rectal content source is considered. Generally, the ICRP models have been designed to predict the amount of radiation dose in the human body from a "typical" or "reference" individual in a given population. The study has been performed to

  16. 2D Fast Vessel Visualization Using a Vessel Wall Mask Guiding Fine Vessel Detection

    Directory of Open Access Journals (Sweden)

    Sotirios Raptis

    2010-01-01

    and then try to approach the ridges and branches of the vasculature's using fine detection. Fine vessel screening looks into local structural inconsistencies in vessels properties, into noise, or into not expected intensity variations observed inside pre-known vessel-body areas. The vessels are first modelled sufficiently but not precisely by their walls with a tubular model-structure that is the result of an initial segmentation. This provides a chart of likely Vessel Wall Pixels (VWPs yielding a form of a likelihood vessel map mainly based on gradient filter's intensity and spatial arrangement parameters (e.g., linear consistency. Specific vessel parameters (centerline, width, location, fall-away rate, main orientation are post-computed by convolving the image with a set of pre-tuned spatial filters called Matched Filters (MFs. These are easily computed as Gaussian-like 2D forms that use a limited range sub-optimal parameters adjusted to the dominant vessel characteristics obtained by Spatial Grey Level Difference statistics limiting the range of search into vessel widths of 16, 32, and 64 pixels. Sparse pixels are effectively eliminated by applying a limited range Hough Transform (HT or region growing. Major benefits are limiting the range of parameters, reducing the search-space for post-convolution to only masked regions, representing almost 2% of the 2D volume, good speed versus accuracy/time trade-off. Results show the potentials of our approach in terms of time for detection ROC analysis and accuracy of vessel pixel (VP detection.

  17. BY FRUSTUM CONFINING VESSEL

    Directory of Open Access Journals (Sweden)

    Javad Khazaei

    2016-09-01

    Full Text Available Helical piles are environmentally friendly and economical deep foundations that, due to environmental considerations, are excellent additions to a variety of deep foundation alternatives available to the practitioner. Helical piles performance depends on soil properties, the pile geometry and soil-pile interaction. Helical piles can be a proper alternative in sensitive environmental sites if their bearing capacity is sufficient to support applied loads. The failure capacity of helical piles in this study was measured via an experimental research program that was carried out by Frustum Confining Vessel (FCV. FCV is a frustum chamber by approximately linear increase in vertical and lateral stresses along depth from top to bottom. Due to special geometry and applied bottom pressure, this apparatus is a proper choice to test small model piles which can simulate field stress conditions. Small scale helical piles are made with either single helix or more helixes and installed in fine grained sand with three various densities. Axial loading tests including compression and tension tests were performed to achieve pile ultimate capacity. The results indicate the helical piles behavior depends essentially on pile geometric characteristics, i.e. helix configuration and soil properties. According to the achievements, axial uplift capacity of helical model piles is about equal to usual steel model piles that have the helixes diameter. Helical pile compression bearing capacity is too sufficient to act as a medium pile, thus it can be substituted other piles in special geoenvironmental conditions. The bearing capacity also depends on spacing ratio, S/D, and helixes diameter.

  18. Southeast Region Headboat Survey-Vessel list/Vessel Directory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is a database of vessels that have been on the SRHS through time, their owners/operators, marinas/docks and their contact information. This assists in...

  19. Optoacoustic online dosimetry during selective RPE treatment

    Science.gov (United States)

    Schuele, Georg; Elsner, Hanno; Hoerauf, Hans; Framme, Carsten; Roider, Johann; Birngruber, Reginald; Brinkmann, Ralf

    2004-07-01

    Introduction: The selective RPE treatment (SRT) is a new method, which targets retinal diseases associated with disorders in the retinal pigment epithelium (RPE). By applying a train of μs laser pulses, it is possible to selectively damage RPE cells while sparing the adjacent photoreceptors and the neural retina. Due to the ophthalmoscopic invisibility of the RPE effects we investigated an optoacoustic (OA) on-line dosimetry system to monitor RPE damage non-invasively. Material and Methods: For in vitro experiments porcine RPE was irradiated with a Nd:YLF laser pulse train (527nm, 1.7μs, 5-40μJ, 30 pulses, 100 Hz). Pressure waves (optoacoustic transients) generated at the RPE were measured with a piezoelectric transducer. The RPE cell damage was visualised by fluorescence microscopy by means of the vitality stain CalceinAM. During 27 patient treatments (527nm, 1.7μs, 50-150μJ, 30 pulses, 100 Hz) the optoacoustic signals were measured with an ultrasonic transducer embedded in the contact lens. The RPE leakage was visualized by fluorescein and ICG angiography. Results: In vitro: Below the RPE cell damage threshold, the optoacoustic transients from each single pulse are almost similar. With RPE damage, fluctuations of the individual transients are observed during the pulse train. These fluctuations can be explained by statistical irregular microbubble formation around the strong light absorbing melanosomes inside the RPE cells, which occur after the temperature exceeds the vaporization threshold. The transient microbubbles probably lead to RPE cell disruption. An optoacoustic value (OA-value) calculated from the fluctuations was defined in order to assess RPE damage. Patient treatment: If optoacoustic pulse-to-pulse fluctuations were measured, RPE leakage was observed in fluorescein and ICG angiography. In 96% of the irradiated areas, RPE-leakage in fluorescein angiography and OA-value correlated. The stronger the optoacoustic pulse-to-pulse fluctuations, thus

  20. A new silicon tracker for proton imaging and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, J.T., E-mail: jtaylor@hep.ph.liv.ac.uk [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Waltham, C. [Laboratory of Vision Engineering, School of Computer Science, University of Lincoln, Lincoln LN6 7TS (United Kingdom); Price, T. [School of Physics and Astronomy, University of Birmingham, Birmingham B25 2TT (United Kingdom); Allinson, N.M. [Laboratory of Vision Engineering, School of Computer Science, University of Lincoln, Lincoln LN6 7TS (United Kingdom); Allport, P.P. [School of Physics and Astronomy, University of Birmingham, Birmingham B25 2TT (United Kingdom); Casse, G.L. [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Kacperek, A. [Douglas Cyclotron, The Clatterbridge Cancer Centre NHS Foundation Trust, Clatterbridge Road, Bebington, Wirral CH63 4JY (United Kingdom); Manger, S. [Department of Physics, University of Warwick, Coventry CV4 7AL (United Kingdom); Smith, N.A.; Tsurin, I. [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom)

    2016-09-21

    For many years, silicon micro-strip detectors have been successfully used as tracking detectors for particle and nuclear physics experiments. A new application of this technology is to the field of particle therapy where radiotherapy is carried out by use of charged particles such as protons or carbon ions. Such a treatment has been shown to have advantages over standard x-ray radiotherapy and as a result of this, many new centres offering particle therapy are currently under construction around the world today. The Proton Radiotherapy, Verification and Dosimetry Applications (PRaVDA) consortium are developing instrumentation for particle therapy based upon technology from high-energy physics. The characteristics of a new silicon micro-strip tracker for particle therapy will be presented. The array uses specifically designed, large area sensors with technology choices that follow closely those taken for the ATLAS experiment at the HL-LHC. These detectors will be arranged into four units each with three layers in an x–u–v configuration to be suitable for fast proton tracking with minimal ambiguities. The sensors will form a tracker capable of tracing the path of ~200 MeV protons entering and exiting a patient allowing a new mode of imaging known as proton computed tomography (pCT). This will aid the accurate delivery of treatment doses and in addition, the tracker will also be used to monitor the beam profile and total dose delivered during the high fluences used for treatment. We present here details of the design, construction and assembly of one of the four units that will make up the complete tracker along with its characterisation using radiation tests carried out using a {sup 90}Sr source in the laboratory and a 60 MeV proton beam at the Clatterbridge Cancer Centre.

  1. A new silicon tracker for proton imaging and dosimetry

    Science.gov (United States)

    Taylor, J. T.; Waltham, C.; Price, T.; Allinson, N. M.; Allport, P. P.; Casse, G. L.; Kacperek, A.; Manger, S.; Smith, N. A.; Tsurin, I.

    2016-09-01

    For many years, silicon micro-strip detectors have been successfully used as tracking detectors for particle and nuclear physics experiments. A new application of this technology is to the field of particle therapy where radiotherapy is carried out by use of charged particles such as protons or carbon ions. Such a treatment has been shown to have advantages over standard x-ray radiotherapy and as a result of this, many new centres offering particle therapy are currently under construction around the world today. The Proton Radiotherapy, Verification and Dosimetry Applications (PRaVDA) consortium are developing instrumentation for particle therapy based upon technology from high-energy physics. The characteristics of a new silicon micro-strip tracker for particle therapy will be presented. The array uses specifically designed, large area sensors with technology choices that follow closely those taken for the ATLAS experiment at the HL-LHC. These detectors will be arranged into four units each with three layers in an x-u-v configuration to be suitable for fast proton tracking with minimal ambiguities. The sensors will form a tracker capable of tracing the path of 200 MeV protons entering and exiting a patient allowing a new mode of imaging known as proton computed tomography (pCT). This will aid the accurate delivery of treatment doses and in addition, the tracker will also be used to monitor the beam profile and total dose delivered during the high fluences used for treatment. We present here details of the design, construction and assembly of one of the four units that will make up the complete tracker along with its characterisation using radiation tests carried out using a 90Sr source in the laboratory and a 60 MeV proton beam at the Clatterbridge Cancer Centre.

  2. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2011-04-04

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanford’s DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision

  3. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2010-04-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanford’s DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision

  4. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2007-03-12

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Revision Log: Rev. 0 (2/25/2005) Major revision and expansion. Rev. 0.1 (3/12/2007) Minor

  5. Research on risk long range identification for vessel traffic dynamic system

    Science.gov (United States)

    Qi, Ji; Guo, Ruijuan; Wang, Xiaoyu; Zhang, Hainan

    2017-09-01

    Vessel Long-range identification and tracking system has already been widely installed and applied in vessel. In this paper AIS system, vessel reporting system and LRIT in China are compared and analyzed based on the coverage area, confidentiality and accuracy of the LRIT information. Vessel Long-range identification and tracking model is established through a combination of AIS with LRIT system, which is applied to the research of vessel traffic dynamic system risk long range identification. Finally, the application of LRIT in the maritime field is discussed.

  6. Oxygen measurements to improve singlet oxygen dosimetry

    Science.gov (United States)

    Kim, Michele M.; Penjweini, Rozhin; Ong, Yi Hong; Finlay, Jarod C.; Zhu, Timothy C.

    2017-02-01

    Photodynamic therapy (PDT) involves interactions between the three main components of light fluence, photosensitizer concentration, and oxygenation. Currently, singlet oxygen explicit dosimetry (SOED) has focused on the first two of these components. The macroscopic model to calculate reacted singlet oxygen has previously involved a fixed initial ground state oxygen concentration. A phosphorescence-based oxygen probe was used to measure ground state oxygen concentration throughout treatments for mice bearing radioactively induced fibroscarcoma tumors. Photofrin-, BPD-, and HPPH-mediated PDT was performed on mice. Model-calculated oxygen and measured oxygen was compared to evaluate the macroscopic model as well as the photochemical parameters involved. Oxygen measurements at various depths were compared to calculated values. Furthermore, we explored the use of noninvasive diffuse correlation spectroscopy (DCS) to measure tumor blood flow changes in response to PDT to improve the model calculation of reacted singlet oxygen. Mice were monitored after treatment to see the effect of oxygenation on long-term recurrence-free survival as well as the efficacy of using reacted singlet oxygen as a predictive measure of outcome. Measurement of oxygenation during treatment helps to improve SOED as well as confirm the photochemical parameters involved in the macroscopic model. Use of DCS in predicting oxygenation changes was also investigated.

  7. IMBA Expert: internal dosimetry made simple.

    Science.gov (United States)

    Birchall, A; Puncher, M; James, A C; Marsh, J W; Jarvis, N S; Peace, M S; Davis, K; King, D J

    2003-01-01

    In 1997, a collaboration between British Nuclear Fuels plc (BNFL), Westlakes Research Institute and NRPB started, with the aim of producing IMBA (Integrated Modules for Bioassay Analysis), a suite of software modules that implement the new ICRP models for estimation of intakes and doses. This was partly in response to new UK regulations, and partly due to the requirement for a unified approach in estimating intakes and doses from bioassay measurements within the UK. Over the past 5 years, the IMBA modules have been developed further, have gone through extensive quality assurance, and are now used for routine dose assessment by approved dosimetry services throughout the UK. More recently, interest in the IMBA methodology has been shown by the United States Department of Energy (USDOE), and in 2001 an ambitious project to develop a software package (IMBA Expert USDOE Edition) which would meet the requirements of all of the major USDOE sites began. Interest in IMBA Expert is now being expressed in many other countries. The aim of this paper is to outline the origin and evolution of the IMBA modules (the past); to describe the full capabilities of the current IMBA Expert system (the present) and to indicate possible future directions in terms of capabilities and availability (the future).

  8. Artificial neural networks in neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Hernandez D, V.M.; Manzanares A, E.; Mercado, G.A.; Perales M, W.A.; Robles R, J.A. [Unidades Academicas de Estudios Nucleares, UAZ, A.P. 336, 98000 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Depto. de Ingenieria Nuclear, Universidad Politecnica de Madrid, (Spain)

    2005-07-01

    An artificial neural network has been designed to obtain the neutron doses using only the Bonner spheres spectrometer's count rates. Ambient, personal and effective neutron doses were included. 187 neutron spectra were utilized to calculate the Bonner count rates and the neutron doses. The spectra were transformed from lethargy to energy distribution and were re-binned to 31 energy groups using the MCNP 4C code. Re-binned spectra, UTA4 response matrix and fluence-to-dose coefficients were used to calculate the count rates in Bonner spheres spectrometer and the doses. Count rates were used as input and the respective doses were used as output during neural network training. Training and testing was carried out in Mat lab environment. The artificial neural network performance was evaluated using the {chi}{sup 2}- test, where the original and calculated doses were compared. The use of Artificial Neural Networks in neutron dosimetry is an alternative procedure that overcomes the drawbacks associated in this ill-conditioned problem. (Author)

  9. Computational high-resolution heart phantoms for medical imaging and dosimetry simulations.

    Science.gov (United States)

    Gu, Songxiang; Gupta, Rajiv; Kyprianou, Iacovos

    2011-09-21

    Cardiovascular disease in general and coronary artery disease (CAD) in particular, are the leading cause of death worldwide. They are principally diagnosed using either invasive percutaneous transluminal coronary angiograms or non-invasive computed tomography angiograms (CTA). Minimally invasive therapies for CAD such as angioplasty and stenting are rendered under fluoroscopic guidance. Both invasive and non-invasive imaging modalities employ ionizing radiation and there is concern for deterministic and stochastic effects of radiation. Accurate simulation to optimize image quality with minimal radiation dose requires detailed, gender-specific anthropomorphic phantoms with anatomically correct heart and associated vasculature. Such phantoms are currently unavailable. This paper describes an open source heart phantom development platform based on a graphical user interface. Using this platform, we have developed seven high-resolution cardiac/coronary artery phantoms for imaging and dosimetry from seven high-quality CTA datasets. To extract a phantom from a coronary CTA, the relationship between the intensity distribution of the myocardium, the ventricles and the coronary arteries is identified via histogram analysis of the CTA images. By further refining the segmentation using anatomy-specific criteria such as vesselness, connectivity criteria required by the coronary tree and image operations such as active contours, we are able to capture excellent detail within our phantoms. For example, in one of the female heart phantoms, as many as 100 coronary artery branches could be identified. Triangular meshes are fitted to segmented high-resolution CTA data. We have also developed a visualization tool for adding stenotic lesions to the coronaries. The male and female heart phantoms generated so far have been cross-registered and entered in the mesh-based Virtual Family of phantoms with matched age/gender information. Any phantom in this family, along with user

  10. Student perceptions of an online medical dosimetry program.

    Science.gov (United States)

    Lenards, Nishele

    2011-01-01

    The University of Wisconsin-La Crosse offers the first online medical dosimetry program in the nation. There is no data to research a program of this type. This research consisted of the evaluation of other distance education programs including health profession programs in addition to face-to-face medical dosimetry programs. There was a need to collect and analyze student perceptions of online learning in medical dosimetry. This research provided a guide for future implementation by other programs as well as validated the University of Wisconsin-La Crosse program. Methodology used consisted of an electronic survey sent to all previous and currently enrolled students in the University of Wisconsin-La Crosse medical dosimetry program. The survey was both quantitative and qualitative in demonstrating attitudinal perceptions of students in the program. Quantitative data was collected and analyzed using a 5-point Likert scale. Qualitative data was gathered based on the open-ended responses and the identifying themes from the responses. The results demonstrated an overall satisfaction with this program, the instructor, and the online courses. Students felt a sense of belonging to the courses and the program. Considering that a majority of the students had never taken an online course previously, the students felt there were no technology issues. Future research should include an evaluation of board exam statistics for students enrolled in the online and face-to-face medical dosimetry programs. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  11. The relevance of dosimetry in animal models of cochlear irradiation.

    Science.gov (United States)

    Mujica-Mota, Mario A; Devic, Slobodan; Daniel, Sam J

    2014-04-01

    To compare dose measurements of three different irradiation setups for an animal model of unilateral cochlear irradiation using radiochromic films positioned at the cochlear plane. A method of dosimetry is proposed. Radiation field simulation was performed to locate the cochlear plane for irradiation experiments using CT scan images. Fifteen film pieces were irradiated at the cochlear plane with 3 different irradiation field sizes. A 12-mm diameter field (n = 5), 5.7 mm diameter field (n = 5), and a 6.5 × 7.2 mm field (n = 5). After obtaining an ideal irradiation field size, 15 film pieces were used to compare dosimetry between tissue substitute materials (PVC n = 5 and PVC + Teflon, 5 each) and real tissue (frozen animal, n = 5). Auditory brainstem responses at 3 frequencies (8, 16, 20, and 25 kHz) were performed on 7 guinea pigs after a cycle of fractionated unilateral irradiation. Dosimetry in real tissue demonstrated an asymmetric dose distribution at the cochlear plane and ultimately a lower dose deposition (30%) when compared with tissue substitute materials. Auditory brainstem responses of ears subjected to radiotherapy demonstrated progressive hearing loss in long-term assessment. Asymmetric dose deposition at the cochlear plane highlights the need of comprehensive real tissue dosimetry in animal studies of cochlear irradiation. To avoid misleading discrepancies in dose-deposition between different studies using the same animal model, appropriate planning and confirmatory dosimetry systems are highly desirable.

  12. 2013 East Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  13. SC/OQ Vessel Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data tables holding information for the Surf Clam/Ocean Quahog vessel and dealer/processor logbooks (negative and positive), as well as individual tag information...

  14. 2011 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  15. 2011 West Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  16. 2013 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  17. 2011 East Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  18. Integrin binding: Sticking around vessels

    Science.gov (United States)

    Blatchley, Michael R.; Gerecht, Sharon

    2017-09-01

    A study demonstrates that controlled integrin binding on a biomaterial was capable of promoting vascular cell sprouting and formation of a non-leaky blood vessel network in a healthy and diseased state.

  19. Transposition of the great vessels

    Science.gov (United States)

    ... vessel called the ductus arteriosus open, allowing some mixing of the 2 blood circulations. A procedure using ... they are not already immune. Eating well, avoiding alcohol, and controlling diabetes both before and during pregnancy ...

  20. 2013 West Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...