Causes and prevention of in-stent restenosis of vertebral artery origin after stenting
International Nuclear Information System (INIS)
Zhao Huipin; Li Shenmao; Zhang Guangping
2010-01-01
Vertebral artery stenosis is an important cause of posterior circulation stroke. Vertebral artery stenosis most commonly occurs at its origin site. In recent years, balloon angioplasty and stent implantation have been widely employed in the treatment of vertebral artery origin stenosis. However, the long term outcome of stent implantation is affected by in-stent restenosis. Multiple contributory factors have been identified, but clear understanding of the overall underlying mechanism remains an enigma. With the development of pathophysiology, prevention and treatment methods of in-stent restenosis have been improved. In recent years, drug-eluting stents, radioactive stents and magnetic stents have been widely applied. To some extent, these stents and drug therapy can solve the problem of restenosis. This article aims to review the clinical application and the up-to-date research progresses in preventing and managing vertebral artery origin restenosis. (authors)
Qiao, Aike; Dai, Xuan; Niu, Jing; Jiao, Liqun
2016-01-01
Hemodynamic factors may affect the potential occurrence of in-stent restenosis (ISR) after intervention procedure of vertebral artery ostial stenosis (VAOS). The purpose of the present study is to investigate the influence of stent protrusion length in implantation strategy on the local hemodynamics of the VAOS. CTA images of a 58-year-old female patient with posterior circulation transient ischemic attack were used to perform a 3D reconstruction of the vertebral artery. Five models of the vertebral artery before and after the stent implantation were established. Model 1 was without stent implantation, Model 2-5 was with stent protruding into the subclavian artery for 0, 1, 2, 3 mm, respectively. Computational fluid dynamics simulations based on finite element analysis were employed to mimic the blood flow in arteries and to assess hemodynamic conditions, particularly the blood flow velocity and wall shear stress (WSS). The WSS and the blood flow velocity at the vertebral artery ostium were reduced by 85.33 and 35.36% respectively after stents implantation. The phenomenon of helical flow disappeared. Hemodynamics comparison showed that stent struts that protruded 1 mm into the subclavian artery induced the least decrease in blood speed and WSS. The results suggest that stent implantation can improve the hemodynamics of VAOS, while stent struts that had protruded 1 mm into the subclavian artery would result in less thrombogenesis and neointimal hyperplasia and most likely decrease the risk of ISR.
Use of a wire extender during neuroprotected vertebral artery angioplasty and stenting.
Lesley, Walter S; Kumar, Ravi; Rangaswamy, Rajesh
2010-09-01
The off-label use of an extender wire during vertebral artery stenting and angioplasty with or with neuroprotection has not been previously reported. Retrospective, single-patient, technical report. After monorail balloon angioplasty was performed on a proximal left vertebral artery stenosis, the 190 cm long Accunet neuroprotection filter device was not long enough for delivery of an over-the-wire stent. After mating a 145 cm long, 0.014 inch extension wire to the filter device, a balloon-mounted Liberté stent was implanted with good angiographic and clinical results. The off-label use of an extender wire permits successful over-the-wire stenting on a monorail neuroprotection device for vertebral artery endosurgery.
Energy Technology Data Exchange (ETDEWEB)
Wang, Zi-Liang [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Gao, Bu-Lang [Department of Medical Research Shijiazhuang First Hospital, Hebei Medical University (China); Li, Tian-Xiao, E-mail: litianxiaod@163.com [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Cai, Dong-Yang; Zhu, Liang-Fu; Bai, Wei-Xing; Xue, Jiang-Yu; Li, Zhao-Shuo [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China)
2015-09-15
Highlights: • Symptomatic vertebral artery stenosis can be treated with intracranial stenting. • Stenting for intracranial vertebral artery stenosis is safe and effective. • Stenting for intracranial vertebral artery stenosis can prevent long-term stroke. - Abstract: Purpose: To investigate the safety, effect and instent restenosis rate of Wingspan stenting in treating patients with intracranial vertebral artery atherosclerotic stenosis (70–99%) concurrent with contralateral vertebral artery atherosclerotic diseases. Materials and methods: Eighty-eight patients with severe symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) combined with contralateral vertebral artery atherosclerotic diseases were treated with the Wingpsan stent. All the baseline, cerebral angiography, success rate, perioperative complications, clinical and imaging follow-up data were prospectively analyzed. Results: The success rate of stenting was 100%, and the mean stenotic rate was reduced from prestenting (84.9 ± 6.8)% to poststenting (17.2 ± 5.9)%. The perioperative stroke rate was 1.1%. Among eighty patients (90.9%) with clinical follow-up 8-62 months (mean 29.3 ± 17.2) poststenting, five (6.3%) had posterior circulation TIA only, three (3.8%) had mild stroke in the posterior circulation but recovered completely, and another five patients greater than 70 years old died of non-ischemic stroke. Imaging follow-up in 46 patients (52.3%) 5–54 months (mean 9.9 ± 9.9) following stenting revealed instent restenosis in 12 patients (26.1%) including 7 (58.3%) symptomatic restenosis. Age and residual stenosis were the two factors to significantly (P < 0.05) affect instent restenosis. Conclusion: Wingspan stenting in the intracranial vertebral artery atherosclerotic stenosis combined with contralateral vertebral artery atherosclerotic diseases has a low perioperative stroke rate and a good preventive effect on long-term ischemic stroke, but the instent restenosis
Directory of Open Access Journals (Sweden)
Fang-fang HAO
2018-01-01
Full Text Available Objective To systematically review the risk factors for in-stent restenosis (ISR of vertebral artery origin after sent implantation to provide theoretical foundation for clinical prevention and treatment. Methods Taking vertebral artery, vertebrobasilar insufficiency, stents, drug-eluting stents, self expandable metallic stents in English and Chinese as key words, retrospective clinical studies about risk factors for ISR of vertebral artery origin were searched by using PubMed, EMBASE/SCOPUS, Cochrane Library, China Biology Medicine (CBM, China National Knowledge Infrastructure (CNKI, Wanfang Data and VIP database from January 1, 1966 to March 30, 2017. Quality assessment and Meta-analysis were made by using Newcastle-Ottawa Scale (NOS and Stata 12.0 software. Results The research enrolled 3468 articles in all, from which 11 studies were chosen after excluding duplicates and those not meeting the inclusion criteria. A total number of 1352 patients were divided into ISR group (N = 440 and non-ISR group (N = 912. The ISR incidence rate of smokers was significantly higher than non-smokers (OR = 2.179, 95%CI: 1.373-3.458; P = 0.001. The differences of bare metal stents (BMS utilization rate (OR = 2.072, 95% CI: 1.560-2.753; P = 0.000 and drug-eluting stents (DES utilization rate (OR = 0.483, 95% CI: 0.363-0.641; P = 0.000 between ISR group and non-ISR group were statistically significant. Conclusions Smoking and using BMS are risk factors for ISR of vertebral artery origin, and using DES is protective factor. Due to limited study quality, more high-quality studies are needed to verify this conclusion. DOI: 10.3969/j.issn.1672-6731.2017.12.004
Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery
Energy Technology Data Exchange (ETDEWEB)
Weber, W. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Mayer, T.E. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Henkes, H. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Kis, B. [Department of Neurology, Alfried Krupp Hospital, Essen (Germany) and Department of Psychiatry and Psychotherapy, University of Duisburg-Essen, Virchow Street 174, D-45147 Essen (Germany)]. E-mail: bernhard.kis@uni-duisburg-essen.de; Hamann, G.F. [Department of Neurology, Klinikum Grosshadern, University of Munich (Germany); Holtmannspoetter, M. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Brueckmann, H. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Kuehne, D. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany)
2005-11-01
Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.
Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery
International Nuclear Information System (INIS)
Weber, W.; Mayer, T.E.; Henkes, H.; Kis, B.; Hamann, G.F.; Holtmannspoetter, M.; Brueckmann, H.; Kuehne, D.
2005-01-01
Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found
Vertebral artery origin stent placement with distal protection: technical and clinical results.
Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N
2006-05-01
To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.
Chang, Jun Young; Park, Hyun; Kwon, Oki
2017-01-01
We have performed stenting in 11 patients with symptomatic vertebral arterial orifice stenosis refractory to medical treatment or impairment in anterior circulation. Three of the 11 patients experienced asymptomatic severe in-stent restenosis or occlusion. Bare metal stents were used in those three patients, two of whom received revascularization therapy. Development of sufficient cervical collateral channels reconstituting the distal vertebral artery was the common feature in patients with asymptomatic in-stent restenosis. In selecting appropriate stents, consideration of mechanical strength and drug-eluting properties of a stent according to characteristics of the target vessel is important to reduce the risk of in-stent restenosis. Any decision to perform revascularization should be based on the presence of abundant cervical collaterals as well as clinical symptoms of vertebrobasilar ischemia. PMID:28304206
International Nuclear Information System (INIS)
Kim, Hyun Jin; Jeong, Hae Woong; Cho, Jae Kwoeng; Park, Jeong Hoon; Koo, Yong Woon; Baik, Seung Kug
2002-01-01
A dissecting aneurysm of the vertebral artery may be treated conservatively, surgically, or using an endovascular approach. Proximal clipping, wrapping or trapping are surgical treatment methods, and endovascular treatment with coils and balloons is performed where a dissecting aneurysm is located near the midline or the appropriate surgical manipulation is difficult. As the contralateral vertebral artery of this patient was hypoplastic, the stent-assisted coil embolization technique was employed to preserve the ipsilateral vertebral artery. We describe a clinical case of dissecting aneurysm of the vertebral artery occurring in a patient in whom a hypoplastic contralateral vertebral artery was successfully treated
International Nuclear Information System (INIS)
Yip, H.-K.; Youssef, Ali A.; Chang, W.-N.; Lu, C.-H.; Yang, C.-H.; Chen, S.-M.; Wu, C.-J.
2007-01-01
Objectives. This study investigated whether the transradial artery (TRA) approach using a 6-French (F) Kimny guiding catheter for right vertebral artery (VA) angiographic study and stenting is safe and effective for patients with significant VA stenosis. Background. The TRA approach is commonly performed worldwide for both diagnostic cardiac catheterization and catheter-based coronary intervention. However, to our knowledge, the safety and feasibility of left and right VA angiographic study and stenting, in the same procedure, using the TRA approach for patients with brain ischemia have not been reported. Methods. The study included 24 consecutive patients (22 male, 2 female; age, 63-78 years). Indications for VA angiographic study and stenting were (1) prior stroke or symptoms related to vertebrobasilar ischemia and (2) an asymptomatic but vertebral angiographic finding of severe stenosis (>70%). A combination of the ipsilateral and retrograde-engagement technique, which involved a looping 6-F Kimny guiding catheter, was utilized for VA angiographic study. For VA stenting, an ipsilateral TRA approach with either a Kimny guiding catheter or a left internal mammary artery guiding catheter was utilized in 22 patients and retrograde-engagement technique in 2 patients. Results. A technically successful procedure was achieved in all patients, including left VA stenting in 15 patients and right VA stenting in 9 patients. The mean time for stenting (from engagement to stent deployment) was 12.7 min. There were no vascular complications or mortality. However, one patient suffered from a transient ischemic attack that resolved within 3 h. Conclusion. We conclude that TRA access for both VA angiographic study and VA stenting is safe and effective, and provides a simple and useful clinical tool for patients unsuited for femoral arterial access
Energy Technology Data Exchange (ETDEWEB)
Alzamora, M.G.; Klisch, J. [Section of Neuroradiology, Neurocenter, University of Freiburg (Germany); Rosahl, S.K.; Lehmberg, J. [Department of Neurosurgery, Neurocenter, University of Freiburg (Germany)
2005-04-01
The incidence of injury to the cervical vertebral artery during surgery for stenosis of the cervical neuroforamina is very low. We present a case in which bleeding during microforaminotomy at the level C6/7 occurred. The bleeding could be controlled intraoperatively. Two days later, a life-threatening cervical hematoma required urgent bedside evacuation. A false aneurysm of the left cervical vertebral artery was successfully occluded by a modified triple stent-in-stent technique, maintaining the flow in the vessel.
International Nuclear Information System (INIS)
Alzamora, M.G.; Klisch, J.; Rosahl, S.K.; Lehmberg, J.
2005-01-01
The incidence of injury to the cervical vertebral artery during surgery for stenosis of the cervical neuroforamina is very low. We present a case in which bleeding during microforaminotomy at the level C6/7 occurred. The bleeding could be controlled intraoperatively. Two days later, a life-threatening cervical hematoma required urgent bedside evacuation. A false aneurysm of the left cervical vertebral artery was successfully occluded by a modified triple stent-in-stent technique, maintaining the flow in the vessel
International Nuclear Information System (INIS)
Taylor, Robert A.; Memon, Muhammad Zeeshan; Qureshi, Adnan I.; Vazquez, Gabriela; Siddiq, Farhan; Hayakawa, Minako; Chaloupka, John C.
2009-01-01
The study's purpose is to report the technical and clinical outcomes of a patient cohort that underwent vertebral artery ostium stent placement for atherosclerotic stenosis. We retrospectively analyzed a prospectively collected database of neurointerventional procedures performed at a single center from 1999 to 2005. Outcome measures included recurrent transient neurological deficits (TNDs), stroke, and death. Kaplan-Meier analysis was used to estimate stroke- and/or death-free survival at 12 months. Cox proportional hazard was used to identify risk factors for recurrent vertebrobasilar ischemic events. Seventy-two patients with 77 treated vertebral ostial lesions were included. The 30-day stroke and/or death rate was 5.2% (n = 4), although no event was directly related to the vertebral ostium stent placement. Three procedure-related strokes were secondary to attempted stent placement at other sites (one carotid artery and two basilar arteries), and the one death was secondary to the presenting stroke severity. The mean clinical follow-up time available for 66 patients was 9 months. There were 14 TNDs (21%), two strokes (3%), and two deaths (3%) recorded in the follow-up. Recurrent vertebrobasilar ischemic events occurred in nine patients (seven TNDs and two strokes). No recurrent stroke and/or deaths were related to the treated vertebral ostium. Stroke- and/or death-free survival rate (including periprocedural stroke and/or death) was 89 ± 5% at 12 months. No vascular risk factor was significantly associated with recurrent vertebrobasilar ischemic events. Vertebral artery ostium stent placement can be safely and effectively performed with a low rate of recurrent stroke in the territory of the treated vessel. Patients who also underwent attempted treatment of a tandem intracranial stenosis appeared to be at highest risk for periprocedure stroke. (orig.)
International Nuclear Information System (INIS)
Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul
2011-01-01
To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 ± 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.
Energy Technology Data Exchange (ETDEWEB)
Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)
2011-07-15
To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 {+-} 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.
Energy Technology Data Exchange (ETDEWEB)
Baek, Jang Hyun; Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)
2015-06-15
Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.
International Nuclear Information System (INIS)
Baek, Jang Hyun; Kim, Byung Moon
2015-01-01
Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.
Angioplasty or Stenting of Extra- and Intracranial Vertebral Artery Stenoses
International Nuclear Information System (INIS)
Hauth, Elke A.M.; Gissler, H. Martin; Drescher, Robert; Jansen, Christian; Jaeger, Horst J.; Mathias, Klaus D.
2004-01-01
Purpose: To determine the feasibility and safety of angioplasty or angioplasty and stenting of extra- and intracranial vertebral artery (VA) stenosis. Methods: In 16 consecutive patients (9 men, 7 women; mean age 61 years, range 49-74 years) 16 stenotic VAs were treated with angioplasty orangioplasty and stenting. Eleven stenoses were localized in V1 segment,1 stenosis in V2 segment and 4 stenoses in V4 segment of VA. Fourteen VA stenoses were symptomatic, 2 asymptomatic. The etiology of the stenoses was atherosclerotic in all cases. Results:Angioplasty was performed in 8 of 11 V1 and 2 of 4 V4 segments of the VA. In 3 of 11 V1 segments and 2 of 4 V4 segments of the VA we combined angioplasty with stenting. The procedures were successfully performed in 14 of 16 VAs (87%). Complications were asymptomatic vessel dissection resulting in vessel occlusion in 1 of 11 V1 segments and asymptomatic vessel dissection in 2 of 4 V4 segments of the VA. One patient died in the 24-hr period after the procedure because of subarachnoid hemorrhage as a complication following vessel perforation of the treated V4 segment. Conclusion: Angioplasty orangioplasty and stenting of extracranial VA stenoses can be performed with a high technical success rate and a low complication rate. In intracranial VA stenosis the procedure is technically feasible but complications can be life-threatening. The durability and procedural complication rates of primary stenting without using predilation in extra- and intracranial VA stenosis should be defined in the future
Endovascular treatment of three traumatic lesions of the vertebral artery
International Nuclear Information System (INIS)
Galvis, Victor Raul; Medina V, Francisco Jose
2007-01-01
The purpose is to expose the results of the endovascular treatment of three traumatic lesions of the vertebral artery. Methods: in the period from October 2005 to May 2006, three patients with traumatic lesions in the vertebral artery were treated by endovascular therapy with an age average of 32 years. All the procedures were carried out using subtraction digital angiography under anesthesiology supervision and were started with a 5,000 IU heparin bolus, previous antiplatelet medication with clopidogrel. For the treatment of the lesions covered stents and coils were used. results: there were three documented cases of traumatic lesions of the vertebral artery treated by endovascular therapy, in two cases arteriovenous fistulas were identified (between vertebral artery and internal jugular vein) with associated pseudo aneurysms, and in one case a pseudo aneurysm without fistula was found. The first patient was treated with placement of a covered stent, in a second patient the lesion was occluded with coils and a third patient required stent and coils with satisfactory repair of the lesions. Complications were not presented as a result of the procedures. Conclusions: the endovascular treatment for traumatic lesions of the vertebral artery is an alternative with minimum morbidity and reasonable costs avoiding the open surgery and conserving the permeability of the vessel when it is possible
Hijikata, Takamichi; Baba, Eiichi; Shirokane, Kazutaka; Tsuchiya, Atsushi; Nomura, Motohiro
2018-06-01
For a case of dissecting vertebral artery aneurysm (DVAA) in a dominant vertebral artery (VA) or posterior inferior cerebellar artery (PICA)-involving lesion, stent-assisted coil embolization (SACE) is an effective technique to preserve blood flow of the VA. A 41-year-old man presented with subarachnoid hemorrhage. Angiography demonstrated DVAA on the left VA just distal to the PICA, and the right VA was thinner than the left. For this case, SACE was performed to preserve the left VA and PICA. On the 10th day, angiography showed recurrence of the dissection. The dissected portion had thickened and extended to both distal and proximal sides involving the PICA origin and proximal portion to the PICA. A second endovascular embolization was performed and the recurrent dissecting aneurysm was embolized including the main VA cavity. In cases of DVAA, there is a possibility of recurrence after SACE, if a dissecting cavity remains unembolized. Therefore, total embolization is necessary under close observation from multiple angles, including the down-the-barrel view.
International Nuclear Information System (INIS)
Chung, Sun Young; Lee, Deok Hee; Choi, Jin Woo; Choi, Byung Se; In, Hyun Sin; Kim, Sun Mi; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul
2010-01-01
To evaluate our early experience using self-expanding stents to treat atherosclerotic vertebral artery ostial stenosis (VAOS), with respect to technical feasibility and clinical and imaging follow-up results. A total of 20 lesions in 20 patients underwent stenting of the VAOS using a self-expanding stent (Precise RX; Cordis Neurovascular, Miami Lakes, FL). Two patients were asymptomatic. We analyzed the technical success rate, causes of technical failure, occurrence of any vascular or neurological event, and the occurrence of any neurological abnormality or in-stent restenosis (ISR) seen on follow-up. The imaging follow-up was performed with Doppler ultrasound (DUS) as a primary screening modality. One instance of technical failure was caused by failure of the guidewire passage. The stent diameter was 5 mm, and post-stenting balloon dilatations were necessary in all cases. Stent misplacement requiring placement of an additional stent occurred in four cases. Following a 14.8 month average clinical follow-up time, two patients showed anterior circulation ischemia, which was not attributed to the VAOS we treated. Following a 13.7 month average DUS follow-up, five patients showed a mild degree of diffuse or focal intimal thickening in the stent lumen; however, none of the stenosis showed luminal loss of more than 50% and no stent fracture was noted. The use of self-expanding stents for treating VAOS was technically feasible and helped to improve artery patency during our limited follow-up interval
Individualized management for intracranial vertebral artery dissecting aneurysms
Directory of Open Access Journals (Sweden)
SHANG Yan-guo
2012-02-01
Full Text Available Objective To discuss the individualized management strategy for intracranial vertebral artery dissecting aneurysms. Methods Eighteen patients with intracranial vertebral artery dissecting aneurysms were treated with different surgical methods. Results Eighteen patients underwent different surgical treatment. Five patients underwent complete occlusion of the aneurysm and parent artery by coiling, 5 were treated by stent -assisted coiling (3 densely packed coiling and 2 non-densely packed coiling, 4 underwent stent-only therapy and 3 of them presented hemodynamic improvement after surgery, 3 were treated by direct surgical clipping, and 1 underwent occipital artery-posterior inferior cerebellar artery bypass. Two aneurysms ruptured immaturely, in which one patient died on the third day after operation and one patient occurred moderate disablity. Only 1 patient who underwent complete occlusion of aneurysm and parent artery presented temporarily ischemic symptoms. No adverse effects were seen in other patients. Seventeen patients were followed up for 1 month to 3 years, and all the aneurysms were stable. Conclusion There are many kinds of therapeutic methods for intracranial vertebral artery dissecting aneurysms. The patients should be treated according to several factors such as the clinical manifestations, aneurysm configuration, and relationship with the posterior inferior cerebellar artery. The treatment should be individualized.
Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro
2013-02-01
Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.
LENUS (Irish Health Repository)
Ederle, Jörg
2009-10-01
Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).
International Nuclear Information System (INIS)
Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki
2008-01-01
Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)
Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization
International Nuclear Information System (INIS)
Joo, Jin Yang; Ahn, Jung Yong; Chung, Young Sun; Han, In Bo; Chung, Sang Sup; Yoon, Pyeong Ho; Kim, Sang Heum; Choi, Eun Wan
2005-01-01
Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesion was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series
The Incidence and Risk Factors of In-Stent Restenosis for Vertebrobasilar Artery Stenting.
Zheng, Dai; Mingyue, Zhu; Wei, Shi; Min, Li; Wanhong, Chen; Qiliang, Dai; Yongjun, Jiang; Xinfeng, Liu
2018-02-01
In-stent restenosis (ISR) remains a challenge for vertebrobasilar artery stenting (VBAS). We aimed to investigate the incidence and risk factors of ISR. This was a retrospective study. From July 28, 2005, to July 30, 2015, patients who received VBAS with an angiographic follow-up time of 6 to 12 months after surgery were enrolled. The clinical and angiographic issues were recorded and analyzed. In total, 283 patients with 335 stents were incorporated into the study. Vertebral ostial lesions accounted for 73.4% (246/335) of the lesions. During the follow-up period, 58 patients with 60 stents experienced ISR (>50%). Stepwise logistic regression analysis showed that the degree of residual stenosis, stent diameter, and alcohol consumption were independent predictors of ISR. Our study demonstrated the incidence and risk factors of ISR after VBAS. This retrospective study with the largest cohort to date provided insight into the occurrence of ISR after VBAS. Copyright © 2017 Elsevier Inc. All rights reserved.
International Nuclear Information System (INIS)
Yoo, Won Jong; Lim, Yeon Soo; Ahn, Kook Jin; Choi, Byung Gil; Kim, Ji Young; Kim, Sung Hoon
2009-01-01
Objectives: To assess the lumen visibility of extracranial vertebral artery stents examined with 16-slice multi-detector row computed tomography (MDCT) angiography in vivo using a medium-smooth kernel (B30s) and a sharp kernel (B60s), and to compare these with digital subtraction angiography (DSA) after stent placement. Methods: Twenty stents from 20 patients (14 men, 6 women; mean age, 62.7 ± 10.1 years) who underwent CT angiography (CTA) with 16-slice MDCT were retrospectively analyzed. In CT angiograms using a B30s and a B60s, the lumen diameters and CT attenuations of the stented vessels were measured three times by three observers, and artificial luminal narrowing (ALN) was calculated. To assess measurement reliability on CT angiograms, the intraclass correlation coefficient (ICC) was used. DSA served as the reference standard for the in-stent luminal measurements on CT angiography. The median interval between CT angiography and DSA was 1 day (range 1-10). Results: For interobserver reliability, intraclass correlation coefficients for the lumen diameters on CT angiograms with a B30s and a B60s were 0.90 and 0.96, respectively. The lumen diameters on CT angiograms using a B30s were consistently smaller than that on CT angiograms using a B60s (p < 0.01). The mean ALN was 37 ± 7% on CT angiograms using a B30s and 25 ± 9% on CT angiograms using a B60s. The mean CT attenuation in in-stent lumen was 347 ± 55 HU on CT angiograms using a B30s and 295 ± 46 HU on CT angiograms using a B60s. The ALN and CT attenuation within the stented vessels between CT angiograms using a B30s and a B60s was significant (p < 0.01). Conclusions: 16-slice MDCT using a sharp kernel allows good visualization of the stented vessels and is useful in the assessment of vertebral artery stent patency after stent placement.
Endovascular Treatment of a Vertebral Artery Pseudoaneurysm in a Drug User
International Nuclear Information System (INIS)
Mourikis, Dimitrios; Chatziioannou, Achilleas; Doriforou, Ortansia; Skiadas, Vasilios; Koutoulidis, Vasilios; Katsenis, Konstantinos; Vlahos, Lampros
2006-01-01
A 26-year-old drug abuser who presented with sepsis was found to have a pseudoaneurysm in the left vertebral artery. This aneurysm was presumed to be post-traumatic, since the patient reported multiple attempts to inject drugs in the left jugular vein 15 days prior to admission. The pseudoaneurysm was treated effectively with stent-graft placement
Energy Technology Data Exchange (ETDEWEB)
Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Davies, John R.; Weissberg, Peter L. [Addenbrooke' s Hospital and University of Cambridge, Division of Cardiovascular Medicine, Cambridge (United Kingdom); Gillard, Jonathan H. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospitald, University Department of Radiology, Cambridge (United Kingdom)
2005-07-01
Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)
International Nuclear Information System (INIS)
Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M.; Davies, John R.; Weissberg, Peter L.; Gillard, Jonathan H.
2005-01-01
Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)
Directory of Open Access Journals (Sweden)
Ying Song
Full Text Available The retreatment of recurrent intracranial vertebral artery dissecting aneurysms (VADAs after stent assisted coiling (SAC has not yet been studied. The purpose of this study was to evaluate the strategies and outcomes for retreatment of recurrent VADAs after SAC.Between September 2009 and November 2013, six consecutive patients presenting with recurrent intracranial VADAs after SAC were enrolled in this study. They were all male with age ranging from 29 to 54 years (mean age, 46.2 years. The procedures of treatments and angiographic and clinical follow-up were reviewed retrospectively. Retreatment modalities were selected individually according to the characteristics of recurrence. The outcomes of retreatment were evaluated by angiographic and clinical follow-up.Six patients with recurrent intracranial VADAs after SAC were retreated, with second SAC in three patients, coil embolization, double overlapping stents placement and endovascular occlusion with aneurysm trapping in one patient, respectively. Immediate angiographic outcomes of retreatment were: complete occlusion in three patients, nearly complete occlusion in two patients, and contrast medium retention in dissecting aneurysm in one patient. All cases were technically successful. No complications related to endovascular procedures occurred. Angiographic follow-up was available in all five patients treated with second SAC or double overlapping stents, which was complete occlusion in four patients, obliteration of parent artery in one patient, showing no recurrence at 4-11 months (mean: 8.6 months. Clinical follow-up was performed in all six patients at 11-51 months after initial endovascular treatment and at 9-43 months after retreatment. The mRS of last clinical follow-up was excellent in five patients and mild disability in only one patient.Endovascular retreatment is feasible and effective for recurrent intracranial VADAs after SAC. Individualized strategies of retreatment should be
Cerebellar cortical infarct cavities and vertebral artery disease
Energy Technology Data Exchange (ETDEWEB)
Cocker, Laurens J.L. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Kliniek Sint-Jan Radiologie, Brussels (Belgium); Compter, A.; Kappelle, L.J.; Worp, H.B. van der [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, Utrecht (Netherlands); Luijten, P.R.; Hendrikse, J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands)
2016-09-15
Cerebellar cortical infarct cavities are a newly recognised entity associated with atherothromboembolic cerebrovascular disease and worse physical functioning. We aimed to investigate the relationship of cerebellar cortical infarct cavities with symptomatic vertebrobasilar ischaemia and with vascular risk factors. We evaluated the MR images of 46 patients with a recent vertebrobasilar TIA or stroke and a symptomatic vertebral artery stenosis ≥50 % from the Vertebral Artery Stenting Trial (VAST) for the presence of cerebellar cortical infarct cavities ≤1.5 cm. At inclusion in VAST, data were obtained on age, sex, history of vertebrobasilar TIA or stroke, and vascular risk factors. Adjusted risk ratios were calculated with Poisson regression analyses for the relation between cerebellar cortical infarct cavities and vascular risk factors. Sixteen out of 46 (35 %) patients showed cerebellar cortical infarct cavities on the initial MRI, and only one of these 16 patients was known with a previous vertebrobasilar TIA or stroke. In patients with symptomatic vertebrobasilar ischaemia, risk factor profiles of patients with cerebellar cortical infarct cavities were not different from patients without these cavities. Cerebellar cortical infarct cavities are seen on MRI in as much as one third of patients with recently symptomatic vertebral artery stenosis. Since patients usually have no prior history of vertebrobasilar TIA or stroke, cerebellar cortical infarct cavities should be added to the spectrum of common incidental brain infarcts visible on routine MRI. (orig.)
Directory of Open Access Journals (Sweden)
Guiyun Zhang
2017-01-01
Full Text Available Background and Purpose. Spontaneous vertebral artery dissection (SVAD is an important reason for posterior-circulation-ischemic stroke in the young and middle-aged population. Although some previous reports reveal a favorable outcome with conservative therapy, it is still controversial in the treatment of SVAD in some specific patients. Herein, we present our 10 years of clinical experience for SVAD at this location. Material and Methods. 20 patients with 20 SVADs in V2 and V3 segments were retrospectively studied. Clinical manifestations and imageology materials were collected and analyzed. All the patients underwent anticoagulation except for one patient because of contraindication. 14 patients underwent Wingspan stents implantation with general anesthesia. Results. In our sample, ischemia (infarction or transient ischemic attack, TIA was found in all the patients. Angiographic stenosis and dissection aneurysm were the most common findings in the segments mentioned above. 19 of the patients (95% got the excellent imageological and clinical outcomes. Conclusions. According to our experience in this group, although anticoagulation is effective in vertebral artery dissection, interventional therapy for SVADs in V2 and/or V3 segments is preferred in some specific patients. Stent with higher radial supporting and flexibility, such as Wingspan stent, is suggested.
Primary Stenting of Subclavian and Innominate Artery Occlusive Disease: A Single Center's Experience
International Nuclear Information System (INIS)
Brountzos, E. N.; Petersen, B.; Binkert, C.; Panagiotou, I.; Kaufman, J. A.
2004-01-01
Purpose: To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Methods: Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Results: Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Conclusion: Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions
Preliminary Report of Carotid Artery Stenting Using a Tapered Stent
Energy Technology Data Exchange (ETDEWEB)
Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)
2011-10-15
To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.
International Nuclear Information System (INIS)
Lee, Da Un; Kim, Jae Kyu; Jung, Hye Doo; Huh, Tae Wook; Yim, Nam Yeol; Oh, Hyun jun; Choi, Soo Jin Na; Chang, Nam Kyu
2010-01-01
To evaluate the occurrence of superficial femoral artery stent fractures, the risk factors of stent fracture, and the relationship between fractures and clinical findings. Of the 38 patients who underwent treatment with Prote'ge'GPS stenting due to arterial occlusions on the superficial femoral artery, 17 also underwent a clinical analysis. Forty-three stents were inserted in the 17 superficial femoral arteries, ranging between 15 and 50 cm in length, with a mean treated length of 26.4 cm (15-50 cm). A fracture was evaluated by taking a PA and lateral simple radiography, as well as a follow-up evaluation accompanied with a CT angiography, DSA, and a color Doppler sonography. The examination involved the assessment of the difference between bone fractures due to length, placement, and frequency. Fractures occurred in 13 of 43 stents (30.2%). A total of 10 (71.4%) occurred in the upper third, compared to 4 (28.6%) in the lower third of the superficial femoral artery. In addition, 10 stents (71.4%) had a single strut fracture, whereas 4 (28.6%) had multiple strut fractures. A stent fracture occurred more frequently when the stents and lesions were longer (p=0.021, 0.012) and the stents were inserted near the joint. However, there was no significant relationship between stent numbers and the fractures (p=0.126). When the stents were inserted along the popliteal artery, a stent fracture occurred more frequently in the lower third of the artery. The stent fractures did not significantly influence the patency rate of the stented artery (p=0.44) Prote'ge'GPS stents in the superficial femoral artery revealed a considerable number of fractures and the fracture frequency showed a significant relationship with the length of stents and lesions. The closer stent insertion was to the joints, the more frequently fractures occurred. There were no evident significant relationships between the presence of stent fractures and the patency of the stented arteries
Retinal artery occlusion during carotid artery stenting with distal embolic protection device.
Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu
2018-01-01
Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.
Angioplasty and stent placement - peripheral arteries
... medlineplus.gov/ency/article/007393.htm Angioplasty and stent placement - peripheral arteries To use the sharing features ... inside the arteries and block blood flow. A stent is a small, metal mesh tube that keeps ...
Vertebral artery dissecting aneurysms: report of 3 cases and review of the literature
International Nuclear Information System (INIS)
Li Zequn; Zhong Ming; Tan Xianxi; Zhen Weiming; Lu Xianghe; Lin Chen
2005-01-01
Objective: To investigate the features, diagnosis and the ideal therapy of vertebral dissecting aneurysms. Methods: Three vertebral dissecting aneurysms were performed endovascular treatment, 2 with stents implantation and embolization, one parental artery and aneurysm occlusion. The course of the diagnosis and treatment were analyzed correlating with the literature. Results: One male, two female, 56-66 years old. 2 presented SAH, one complained of vertigo. The features on DSA: 2 showed pearl and string sign, that was, aneurismal dilation accompanied by proximal and/or distal narrowing; one demonstrated fusiform aneurysm. Two cases recovered well, one died after procedure. Conclusions: Endovascular treatment is the ideal choice to treat the vertebral dissecting aneurysms. (authors)
Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting
Energy Technology Data Exchange (ETDEWEB)
Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)
2003-08-01
Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)
Primary extracranial vertebral artery aneurysms.
Morasch, Mark D; Phade, Sachin V; Naughton, Peter; Garcia-Toca, Manuel; Escobar, Guillermo; Berguer, Ramon
2013-05-01
Extracranial vertebral artery aneurysms are uncommon and are usually associated with trauma or dissection. Primary cervical vertebral aneurysms are even rarer and are not well described. The presentation and natural history are unknown and operative management can be difficult. Accessing aneurysms at the skull base can be difficult and, because the frail arteries are often afflicted with connective tissue abnormalities, direct repair can be particularly challenging. We describe the presentation and surgical management of patients with primary extracranial vertebral artery aneurysms. In this study we performed a retrospective, multi-institutional review of patients with primary aneurysms within the extracranial vertebral artery. Between January 2000 and January 2011, 7 patients, aged 12-56 years, were noted to have 9 primary extracranial vertebral artery aneurysms. All had underlying connective tissue or another hereditary disorder, including Ehler-Danlos syndrome (n=3), Marfan's disease (n=2), neurofibromatosis (n=1), and an unspecified connective tissue abnormality (n=1). Eight of 9 aneurysms were managed operatively, including an attempted bypass that ultimately required vertebral ligation; the contralateral aneurysm on this patient has not been treated. Open interventions included vertebral bypass with vein, external carotid autograft, and vertebral transposition to the internal carotid artery. Special techniques were used for handling the anastomoses in patients with Ehler-Danlos syndrome. Although endovascular exclusion was not performed in isolation, 2 hybrid procedures were performed. There were no instances of perioperative stroke or death. Primary extracranial vertebral artery aneurysms are rare and occur in patients with hereditary disorders. Operative intervention is warranted in symptomatic patients. Exclusion and reconstruction may be performed with open and hybrid techniques with low morbidity and mortality. Copyright © 2013 Elsevier Inc. All rights
Delayed cerebral infarction due to stent folding deformation following carotid artery stenting
Energy Technology Data Exchange (ETDEWEB)
Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)
2014-12-15
We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.
Directory of Open Access Journals (Sweden)
Szkup Peter
2006-05-01
Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound
Study on the effect of location of intracranial arterial stenosis on the safety of stenting
Directory of Open Access Journals (Sweden)
Yu-jie SUN
2017-11-01
Full Text Available Objective To investigate the effect of location of intracranial arterial stenosis on the safety of intracranial stenting. Methods A total of 73 patients with symptomatic intracranial atherosclerotic stenosis (ICAS were divided into intracranial internal carotid artery (IICA, N = 18, middle cerebral artery (MCA-M1 segment (MCA-M1, N = 11, intracranial vertebral artery (IVA, N = 27 and basilar artery (BA, N = 17. All of them underwent intracranial stenting. The improvement of intracranial arterial stenosis, cerebrovascular complications including perforating events, artery dissection, in-stent thrombosis, distal stent arterial embolism and cerebral hyperperfusion, and neurological complications including transient ischemic attack (TIA, ischemic stroke and intracranial hemorrhage were recorded. Modified Rankin Scale (mRS was used to evaluate the prognosis 30 d after operation. Results A total of 73 stents were implanted in 73 patients (35 Apollo balloon-expandable stents and 38 Wingspan self-expandable stents. Among them, 10 cases (10/18 were treated with Apollo stents and 8 cases (8/18 with Wingspan stents in IICA group, 5 cases (5/11 were treated with Apollo stents and 6 cases (6/11 with Wingspan stents in MCA-M1 group, 16 cases (59.26%, 16/27 were treated with Apollo stents and 11 cases (40.74%, 11/27 with Wingspan stents in IVA group, and 4 cases (4/17 were treated with Apollo stents and 13 cases (13/17 with Wingspan stents in BA group. No significant difference was seen in stent type among 4 groups (χ2 = 7.422, P = 0.201. The stenosis rate of IICA group after treatment [(10.94 ± 1.99%] was significantly improved than before treatment [(90.89 ± 7.71%; t = 69.545, P = 0.000]. The stenosis rate of MCA-M1 group after treatment [(10.37 ± 2.14%] was significantly improved than before treatment [(87.64 ± 9.46%; t = 26.000, P = 0.000]. The stenosis rate of IVA group after treatment [(11.02 ± 1.99% ] was significantly improved than before
Angioplasty and stent placement - carotid artery
... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...
Angioplasty and stent placement - peripheral arteries - discharge
... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...
A Case of Duplicated Right Vertebral Artery.
Motomura, Mayuko; Watanabe, Koichi; Tabira, Yoko; Iwanaga, Joe; Matsuuchi, Wakako; Yoshida, Daichi; Saga, Tsuyoshi; Yamaki, Koh-Ichi
2018-04-27
We encountered a case of duplicated right vertebral artery during an anatomical dissection course for medical students in 2015. Two vertebral arteries were found in the right neck of a 91-year-old female cadaver. The proximal leg of the arteries arose from the area between the right subclavian artery and the right common carotid artery that diverged from the brachiocephalic artery. The distal leg arose from the right subclavian artery as expected. The proximal leg entered the transverse foramen of the fourth cervical vertebra and the distal leg entered the transverse foramen of the sixth cervical vertebra. The two right vertebral arteries joined to form one artery just after the origin of the right vertebral artery of the brachiocephalic artery entered the transverse foramen of the fourth cervical vertebra. This artery then traveled up in the transverse foramina and became the basilar artery, joining with the left vertebral artery. We discuss the embryological origin of this case and review previously reported cases.
Renal artery stent angioplasty for renovascular hypertension
International Nuclear Information System (INIS)
Li Gang; Li Haiqing; Wang Lin
2005-01-01
Objective: To evaluate the therapeutic results of expandable stent for treatment of atherosclerotic renovascular obstructive disease. Methods: 15 patients (10 men and 5 women, 41-75 years old; mean age, 52 years) with renal arterial hypertension underwent renal stent angioplasty including renal arterial stenosis 89%(n=13) and fully obstruction without function in 2, of which 2 patients had bilateral involvement. The stenotic range of all arterial segments showed 60% to 90% width of the normal arterial diameter. 16 stents were implanted under the guidance of fluoroscopy. The most of stents implanted were Palmaz (n=12, 75%) with regular clinical and angiographic follow up. Results: Technical success (residual stenosis <30%) was achieved in all patients without serious complication. During the follow-up (6-15 months; mean, 8 ± 4 months), hypertension was improved in 9 patients and cured in 4 patients with a total benefit of 86% and no efficacy in 2(13%). The average systolic blood pressure decreased from 27.12 ± 3.09 kPa to 18.62 ± 3.12 kPa and the average diastolic blood pressure decreased from 17.73 ± 1.92 kPa to 11.12 ± 2.43 kPa after stent treatment (P<0.05). Serum creatinine remained stable in 60% (n=9) patients with improvement in 33% (n=5) and worsened in 6% (n=1) patients. Follow-up angiography was performed in all patients with 1 case of a restenosis. 6 months after expanding through stent by using balloon, the two follow up angiographies showed a stable restenosis about 20%. Conclusions: Percutaneous transluminal stent placement is highly beneficial for patients who had renal arterial obstructive disease. The success of stent angioplasty of complete obstructive renal arteries reveals wide prospects for interventional method. (authors)
Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries
International Nuclear Information System (INIS)
Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.
2012-01-01
Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.
In-stent restenosis of innominate artery with critical stenosis of right internal carotid artery
International Nuclear Information System (INIS)
Hussain, S.; Raza, A.; Ahmed, W.
2011-01-01
A lady with aortitis syndrome developed in-stent restenosis (ISR) of the innominate artery stent and critical stenosis of right internal carotid artery. The therapeutic challenge was gaining access to the carotid vessel, after treating the innominate artery ISR and all the while using distal protection to circumvent potential cerebral embolism. Percutaneous transluminal angioplasty (PTA) with or without stenting is a safe therapeutic option for re-vascularization of the supra aortic vessels. In the event of re-stenosis, re-treatment with PTA and stenting is safe. Ample evidence-base exists now for carotid artery stenting (CAS) in preference to carotid endarterectomy in patients with stenotic lesions of the carotid vessels. (author)
International Nuclear Information System (INIS)
Dabus, Guilherme; Gerstle, Ronald J.; Derdeyn, Colin P.; Cross, DeWitte T.; Moran, Christopher J.
2006-01-01
We report our experience with the endovascular treatment of the vertebral artery origin in patients presenting with symptomatic vertebrobasilar ischemia and compare our results with those reported in the literature. In 25 patients, 28 procedures were performed. Patients presented with posterior circulation ischemic symptoms despite optimal medical therapy with antiplatelet drugs and had a digital subtraction angiogram demonstrating stenosis of the origin of the vertebral artery greater than 50%. Retrospective review of the medical records, clinical notes and radiologic-procedural reports was performed. Of the 25 patients, 18 were male and 7 female. Their ages ranged from 50 to 84 years. In 23 of the 25 patients the contralateral vertebral artery was occluded, hypoplastic, absent, or had greater than 50% stenosis. In 13 of the 25 patients angiographic evidence of significant anterior circulation disease was demonstrated. In 18 of the 25 patients the left vertebral artery was affected. The mean stenosis was 82.6%. Follow-up records were available in 19 patients. The mean follow-up was 24 months. Five of the 19 patients had recurrent symptoms of vertebrobasilar ischemia and three patients were retreated. Of the 28 procedures performed, 23 were angioplasty/stenting and 5 were angioplasties alone. Overall technical success was achieved in 26 of the 28 procedures (92.8%). No procedure-related transient ischemic attack, stroke or death was noted. Endovascular treatment of the vertebral artery origin in this patient population is feasible, safe, and effective. There are some questions regarding the long-term follow-up and rate of restenosis and clinical recurrences that are yet to be answered. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A
1999-09-01
A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results.
International Nuclear Information System (INIS)
Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A.
1999-01-01
A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results
Predictive Factors of In-Stent Restenosis in Renal Artery Stenting: A Retrospective Analysis
International Nuclear Information System (INIS)
Vignali, Claudio; Bargellini, Irene; Lazzereschi, Michele; Cioni, Roberto; Petruzzi, Pasquale; Caramella, Davide; Pinto, Stefania; Napoli, Vinicio; Zampa, Virna; Bartolozzi, Carlo
2005-01-01
Purpose. To retrospectively evaluate the role of clinical and procedural factors in predicting in-stent restenosis in patients with renovascular disease treated by renal artery stenting. Methods. From 1995 to 2002, 147 patients underwent renal artery stenting for the treatment of significant ostial atherosclerotic stenosis. Patients underwent strict clinical and color-coded duplex ultrasound follow-up. Ninety-nine patients (111 stents), with over 6 months of continuous follow-up (mean 22±12 months, range 6-60 months), were selected and classified according to the presence (group A, 30 patients, 32 lesions) or absence (group B, 69 patients, 79 lesions) of significant in-stent restenosis. A statistical analysis was performed to identify possible preprocedural and procedural predictors of restenosis considering the following data: sex, age, smoking habit, diabetes mellitus, hypertension, serum creatinine, cholesterol and triglyceride levels, renal artery stenosis grade, and stent type, length and diameter. Results. Comparing group A and B patients (χ 2 test), a statistically significant relation was demonstrated between stent diameter and length and restenosis: the risk of in-stent restenosis decreased when the stent was ≥6 mm in diameter and between 15 and 20 mm in length. This finding was confirmed by multiple logistic regression analysis. Stent diameter and length were proved to be significantly related to in-stent restenosis also when evaluating only patients treated by Palmaz stent (71 stents). Conclusion. Although it is based on a retrospective analysis, the present study confirms the importance of correct stent selection in increasing long-term patency, using stents of at least 6 mm in diameter and with a length of approximately 15-20 mm
Giurgea, Georgiana-Aura; Haumer, Markus; Mlekusch, Irene; Sabeti-Sandor, Schila; Dick, Petra; Schillinger, Martin; Minar, Erich; Mlekusch, Wolfgang
2017-07-01
We hypothesize that stenting of the internal carotid artery can immediately impede blood flow to the external carotid artery by either plaque shift or stent coverage of the ostium, and thereby cause ischemic symptoms like ipsilateral jaw claudication. Thirty-three patients with high-grade asymptomatic stenosis of the internal carotid artery who underwent endovascular treatment were examined by ultrasound of the external carotid artery and performed an exercise test by chewing chewing gum synchronously to an electronic metronome for 3 min. Tests were performed before, the day after, and 1 week after the stenting procedure. Claudication time was defined as the timespan until occurrence of pain of the masseter muscle and/or chewing dyssynchrony to the metronome for more than 15 s. Ten patients with an isolated, atherosclerotic stenosis of the external carotid artery served as controls. A significantly reduced claudication time (in seconds) was recorded in patients who underwent carotid artery stenting compared to baseline values; median 89 (interquartile range, IQR, 57 to 124) vs. median 180 (IQR 153 to 180; p external carotid artery into faster or slower as 200 cm/sec, the effect was even accentuated. Stenting values showed improvement 1 week after but did not return to baseline levels. No respective changes were found in controls. Stenting of the internal carotid artery lead to ipsilateral flow deterioration at the external carotid artery resulting in temporary jaw claudication. This impairment attenuated over the time and was significantly reduced after 1 week.
Stent Design Affects Femoropopliteal Artery Deformation.
MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey
2018-03-23
Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.
International Nuclear Information System (INIS)
Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.
2005-01-01
Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)
Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries
International Nuclear Information System (INIS)
Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.
2011-01-01
Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)
An argument for the use of multiple segment stents in curved arteries.
Kasiri, Saeid; Kelly, Daniel J
2011-08-01
Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.
Duplication of the Left Vertebral Artery Origin: A Case Report
Energy Technology Data Exchange (ETDEWEB)
Shin, Sang Wook; Park, Dong Woo; Park, Choong Ki; Lee, Young Jun [Dept. of Radiology, College of Medicine, Hanyang University, Hanyang University Guri Hospital, Guri (Korea, Republic of)
2013-01-15
Duplication of vertebral arteries is a very rare but clinically important condition. A duplicated vertebral artery origin can influence hemodynamics, pathogenesis of vascular lesions and treatment options. In cases of vertebral artery duplication, the vertebral arteries generally enter the transverse foramen higher up than normal. Awareness of these vertebral artery variants before procedures, such as neurointervention or surgery, may be beneficial. Here, we describe a case of a 51-year-old female patient with left vertebral artery duplication which was detected incidentally.
Duplication of the Left Vertebral Artery Origin: A Case Report
International Nuclear Information System (INIS)
Shin, Sang Wook; Park, Dong Woo; Park, Choong Ki; Lee, Young Jun
2013-01-01
Duplication of vertebral arteries is a very rare but clinically important condition. A duplicated vertebral artery origin can influence hemodynamics, pathogenesis of vascular lesions and treatment options. In cases of vertebral artery duplication, the vertebral arteries generally enter the transverse foramen higher up than normal. Awareness of these vertebral artery variants before procedures, such as neurointervention or surgery, may be beneficial. Here, we describe a case of a 51-year-old female patient with left vertebral artery duplication which was detected incidentally.
Lettau, Michael; Bendszus, Martin; Hähnel, Stefan
2013-06-01
Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.
Metallic stent for the treatment of iliac arterial stenosis
Energy Technology Data Exchange (ETDEWEB)
Park, Jae Hyung; Chung, Jin Wook; Han, Joon Koo; Suh, Chul Soo; Yoo, Jae Wook; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of); Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of)
1993-07-15
In order to study the clinical efficacy of the metallic stent of the treatment of iliac arterial stenosis, the clinical and arteriographic findings of the 8 patients were retrospectively reviewed. All 8 patients were males with an age of 51 to 79. The Fontaine class for the functional status of lower extremities was II in 4 patients, III in 3 patents and IV in 1 patient. Self expandable Gianturco stent was inserted of in 7 iliac arteries and balloon expandable Palmaz stent was inserted in 2 iliac arteries in the 8 patients. The indications for the metallic stent application were localized dissection with significant residual stenosis in 6 sites, recoiling due to calcification in one case and eccentricity of the stenosislesionin 2 sites. The deployment of the metallic stent was successful in all the cases to maintain the patency of iliac arteries with residual stenosis less than 30%. The Fontaine class was improved to 1 in 6 patients, IIa in 1 patient and IIb in another one. During the follow up period of 3 to 14 month, none except one developed recurrence of the symptom. On the basis of our experience, we believe that metallic stent is safe and effective for the treatment of iliac arterial stenosis. However, we think that it is a complementary measure to the percutaneous transluminal angioplasty. The comparative study between different types of metallic stent and the long term effect should be investigated further.
Angioplasty and stent placement - carotid artery - discharge
... medlineplus.gov/ency/patientinstructions/000235.htm Angioplasty and stent placement - carotid artery - discharge To use the sharing ... the hospital. You may have also had a stent (a tiny wire mesh tube) placed in the ...
Hepatic artery stent-grafts for the emergency treatment of acute bleeding
Energy Technology Data Exchange (ETDEWEB)
Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)
2014-10-15
Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.
Factors for vertebral artery injury accompanied by cervical trauma
Energy Technology Data Exchange (ETDEWEB)
Murata, Masaaki; Shingu, Hikosuke; Kimura, Isao; Nasu, Yoshiro; Shiotani, Akihide [San-in Rosai Hospital, Yonago, Tottori (Japan). Spine and Low Back Pain Center
2001-09-01
Injury of the vertebral artery with cerebellar and brain stem infarction is a complication of cervical vertebral trauma. However, the pathogenesis and etiological factors remain to be clarified. In this study, we investigated patients with cervical vertebral and cord injury. This study included 51 patients with cervical vertebral and cord injury who were treated in our department. In these patients, plain X-ray, CT, MRI, and MRA findings were examined. The incidence of vertebral arterial injury was 33.3% (17 of 51 patients with cervical vertebral trauma). In 11 of the 17 patients, dislocation fracture was noted, comprising a markedly high percentage (64.7%). Particularly, vertebral arterial injury was commonly observed in patients with a large dislocation distance and severe paralysis. Cerebellar and brain stem infarction related to vertebral arterial injury was observed in 5 of the 17 patients (29.4%). No infarction developed in patients 50 years old or younger. Infarction was detected in relatively elderly patients. Vertebral arterial injury and cerebellar/brain stem infarction related to cervical vertebral trauma were frequently observed in patients with high energy injury. However, these disorders commonly occurred in elderly patients. Therefore, age-related factors such as arteriosclerosis may also be closely involved. In the acute stage, the state of the vertebral artery should be evaluated by MRA and MRI. Among patients with vertebral arterial injury, caution is needed during follow-up those with risk factors such as high energy injury and advanced age. (author)
Factors for vertebral artery injury accompanied by cervical trauma
International Nuclear Information System (INIS)
Murata, Masaaki; Shingu, Hikosuke; Kimura, Isao; Nasu, Yoshiro; Shiotani, Akihide
2001-01-01
Injury of the vertebral artery with cerebellar and brain stem infarction is a complication of cervical vertebral trauma. However, the pathogenesis and etiological factors remain to be clarified. In this study, we investigated patients with cervical vertebral and cord injury. This study included 51 patients with cervical vertebral and cord injury who were treated in our department. In these patients, plain X-ray, CT, MRI, and MRA findings were examined. The incidence of vertebral arterial injury was 33.3% (17 of 51 patients with cervical vertebral trauma). In 11 of the 17 patients, dislocation fracture was noted, comprising a markedly high percentage (64.7%). Particularly, vertebral arterial injury was commonly observed in patients with a large dislocation distance and severe paralysis. Cerebellar and brain stem infarction related to vertebral arterial injury was observed in 5 of the 17 patients (29.4%). No infarction developed in patients 50 years old or younger. Infarction was detected in relatively elderly patients. Vertebral arterial injury and cerebellar/brain stem infarction related to cervical vertebral trauma were frequently observed in patients with high energy injury. However, these disorders commonly occurred in elderly patients. Therefore, age-related factors such as arteriosclerosis may also be closely involved. In the acute stage, the state of the vertebral artery should be evaluated by MRA and MRI. Among patients with vertebral arterial injury, caution is needed during follow-up those with risk factors such as high energy injury and advanced age. (author)
COVERED STENTS IN IATROGENIC CORONARY ARTERY FISTULA; A CASE REPORT
Directory of Open Access Journals (Sweden)
Masoud Poormoghaddas
2010-11-01
Full Text Available Abstract BACKGROUND: Coronary artery fistula is an abnormal communication between a coronary artery and a cardiac chamber or major cardiac vessels, mostly congenital but some of them are acquired as a consequence of coronary artery perforation. CASE PRESENTATION: We report a case of cavity spilling coronary artery perforation during percutaneous coronary intervention 7 years ago. Because of continuing symptoms and risk of developing heart failure and pulmonary hypertension we were ought to treat this iatrogenically formed coronary artery fistula. We used stent graft implantation to treat it with acceptable results. CONCLUSION: Beside their application as a rescue for acute coronary artery perforations, stent grafts can be used with acceptable results in iatrogenically acquired coronary artery coronary artery fistula Keywords: Coronary artery perforation, Coronary artery fistula, Stent graft.
International Nuclear Information System (INIS)
Kim, Jae-Kyu; Kim, Yun-Hyeon; Chung, Sang-Yeung; Kang, Heoung-Keun
1999-01-01
Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent.Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients's chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed.Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery, and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively.Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.
Energy Technology Data Exchange (ETDEWEB)
Suh, Sang Hyun; Chung, Tae-Sub [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea); Lee, Kyung-Yul [Yonsei University College of Medicine, Department of Neurology, Gangnam Severance Hospital, Seoul (Korea); Hong, Chang Ki; Kim, Chang-Hyun [Yonsei University College of Medicine, Department of Neurosurgery, Gangnam Severance Hospital, Seoul (Korea); Kim, Byung Moon; Kim, Dong Ik [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea)
2009-08-15
We describe our experience in which a retrievable Enterprise stent was used as a temporary recanalization and embolectomy device in an acute middle cerebral artery (MCA) occlusion after urgent stenting for ipsilateral carotid artery stenosis. (orig.)
International Nuclear Information System (INIS)
Luo Quanyong; Chen Libo; Yuan Zhibin; Lu Hankui; Zhu Ruisen
2003-01-01
Objective: To investigate the ability of γ-emitting 103 Pd radioactive stent implantation for preventing in-stent restenosis in iliac artery of rabbits. Methods: Twenty New Zealand white rabbits were divided into six groups on the basis of radioactivity loading [2.22 (n=3), 5.55 (n=4), 9.25 (n=4), 14.8 (n=3), 22.2 (n=3), 33.3 MBq (n=3)]. 103 Pd stent was implanted in one of the two iliac arteries of each rabbit and nonradioactive stent in the contralateral artery. The rabbits were fed with high fat diet. Treatment efficiency was assessed by angiography and quantitative histomorphometry of the stented iliac segments 28 d after the implantation. Results: Quantitative histomorphometry analysis indicated that 103 Pd stents induced a significant reduction in neointimal area and the percentage of stenosis within radioactive stents was lower compared with that in the control stents. Nevertheless, the suppression of neointima formation by 103 Pd stent implantation was not in a dose-dependent manner. Conclusions: Low-dose intravascular brachytherapy via a γ-particle-emitting 103 Pd radioactive stent potently inhibits neointimal hyperplasia and prevents the in-stent restenosis in rabbit iliac artery. 103 Pd stent implantation probably can be employed as a novel means to prevent in-stent restenosis
Directory of Open Access Journals (Sweden)
Utku Şenol
2013-03-01
Full Text Available Although coronary artery pseudoaneurysm which couldoccur following percutaneous coronary interventions is arare complication, it can be mortal. As soon as the pseudoaneurysmis diagnosed, it should be treated by percutaneousintervention or surgery. Graft stent implantationis a preferred treatment for appropriate patients. In thiscase report, we presented a successful treatment of coronaryartery pseudoaneurysm by graft stent; which developedafter the implantation of bare metal stent into theleft anterior descending coronary artery. J Clin Exp Invest2013; 4 (1: 126-129Key words: Coronary artery, pseudoaneurysm, graft stent
Distal vertebral artery reconstruction when managing vertebrobasilar insufficiency
Directory of Open Access Journals (Sweden)
D. M. Galaktionov
2017-11-01
Full Text Available This article presents a literature review devoted to the reconstruction of the distal vertebral artery and a clinical case of successful surgical treatment of a patient suffering from vertebrobasilar insufficiency caused by occlusion of the vertebral artery in a proximal segment. The external carotid artery-distal vertebral artery bypass was performed by using the radial artery.Received 27 February 2017. Revised 25 July 2017. Accepted 3 August 2017.Funding: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest.
Basilar artery angulation and vertigo due to the hemodynamic effect of dominant vertebral artery.
Cosar, Murat; Yaman, Mehmet; Eser, Olcay; Songur, Ahmet; Ozen, Oguz A
2008-01-01
Vertebral arteries form the basilar artery at the pontobulbar junction. The vertebral artery may have dominancy in one of them. The branches of basilar arteries supply blood for the vestibular nuclei and its connections. Vertigo is seen generally in the upper middle aged patients. Vertigo can be observed in dolichoectasia of basilar artery such as angulation and elongation, because of the diminished blood supply and changed hemodynamic factors of vestibular nuclei and its connections. We hypothesized that angulation or elongation of basilar artery can be estimated according to the unilateral vertebral artery dominant hypertensive patients. The basilar artery can angulate from the dominant side of vertebral artery to the recessive side. These angulation and elongation can effect the hemodynamic factors in absence of growing collateral arteries. So, the vertigo attacks may occur in these patients.
Stent-assisted angioplasty for intracranial atherosclerosis
International Nuclear Information System (INIS)
Nakahara, Toshinori; Sakamoto, Shigeyuki; Hamasaki, Osamu; Sakoda, Katsuaki
2002-01-01
We report on two patients with intracranial atherosclerosis of the carotid artery or vertebral artery treated with stent-assisted angioplasty. Both patients have severe intracranial atherosclerosis (>70%) with refractory symptoms despite optimal medical treatment. In both patients, a coronary balloon-expandable stent was successfully placed using a protective balloon technique without procedural complications. The patients were asymptomatic and neurologically intact at a mean clinical follow-up of 13 months. Follow-up angiograms did not show restenosis 3 or 4 months after procedure, respectively. Stent-assisted angioplasty for intracranial atherosclerosis in the elective patient has proven effective, with an acceptable low rate of morbidity and mortality. (orig.)
International Nuclear Information System (INIS)
Greil, Oliver; Kleinschmidt, Thomas; Weiss, Wolfgang; Wolf, Oliver; Heider, Peter; Schaffner, Silvio; Gianotti, Marc; Schmid, Thomas; Liepsch, Dieter; Berger, Hermann
2005-01-01
Purpose. To study the influence of a newly developed membrane stent design on flow patterns in a physiologic carotid artery model. Methods. Three different stents were positioned in silicone models of the carotid artery: a stainless steel stent (Wall-stent), a nitinol stent (SelfX), and a nitinol stent with a semipermeable membrane (MembraX). To increase the contact area of the membrane with the vessel wall, another MembranX model was modified at the outflow tract. The membrane consists of a biocompatible silicone-polyurethane copolymer (Elast-Eon) with a pore size of 100 μm. All stents were deployed across the bifurcation and the external carotid artery origin. Flow velocity measurements were performed with laser Doppler anemometry (LDA), using pulsatile flow conditions (Re = 220; flow 0.39 l/min; flow rate ratio ICA:ECA = 70:30) in hemodynamically relevant cross-sections. The hemodynamic changes were analyzed by comparing velocity fluctuations of corresponding flow profiles. Results. The flow rate ratio ICA:ECA shifted significantly from 70/30 to 73.9/26.1 in the MembraX and remained nearly unchanged in the SelfX and Wallstent. There were no changes in the flow patterns at the inflow proximal to the stents. In the stent no relevant changes were found in the SelfX. In the Wallstent the separation zone shifted from the orifice of the ICA to the distal end of the stent. Four millimeters distal to the SelfX and the Wallstent the flow profile returned to normal. In the MembraX an increase in the central slipstreams was found with creation of a flow separation distal to the stent. With a modification of the membrane this flow separation vanished. In the ECA flow disturbances were seen at the inner wall distal to the stent struts in the SelfX and the Wallstent. With the MembraX a calming of flow could be observed in the ECA with a slight loss of flow volume. Conclusions. Stent placement across the carotid artery bifurcation induces alterations of the physiologic flow
International Nuclear Information System (INIS)
Li Zhaoshuo; Li Tianxiao; Wang Ziliang; Bai Weixing; Xue Jiangyu; Zhu Liangfu; Li Li
2013-01-01
Objective: To retrospectively evaluate the cerebrovascular complications from stenting for symptomatic intracranial stenosis and to detect the factors associated with complications. Methods: Medical records of Wingspan stenting were reviewed for 306 cases with symptomatic intracranial stenosis from July 2007 to February 2012, including transient ischemic attack, ischemic stroke, death and intracranial hemorrhage as clinical in-hospital complications. The location of lesions included middle cerebral artery level M1 (114 lesions), intracranial portion of the internal carotid artery (50 lesions), vertebral artery 4 (75 lesions), venebro-basilar artery (14 lesions), basilar artery (76 lesions). Complications were evaluated and analyzed to find out whether they were associated with patient-or stenosis-related risk factors using χ"2 test. Results: The technical success rate was 99% (303/306). Cerebrovascular complications rate was 6.9% (21/303), with 1.6% (14/303) of disabling stroke events and 0.7% (2/303) of deaths. Hemorrhagic events were consisted of procedure-related events (3 cases), hyperperfusion (3 cases), ischemic events of perforator stroke (8 cases), transient ischemic attack (3 cases), embolization (2 cases), thrombosis in stent (2 cases). Hemorrhagic events were associated with significantly higher morbidity and mortality rates (χ"2 = 2.908, P < 0.05) and occurred more frequently after treatment of middle cerebral artery stenosis than other lesions (χ"2 = 1.168, P < 0.05). Perforating branches were detected to be affected mainly in the basilar artery than other locations (χ"2 = 4.263, P < 0.05). Conclusion: The complication rates in the study are preliminary consistent with the previously published data. Hemorrhagic events are prone to occur in the treatment of middle cerebral artery stenosis, while perforating branches are affected mainly in the basilar artery. (authors)
Transpedal approach for iliac artery stenting: A pilot study
Energy Technology Data Exchange (ETDEWEB)
Zachariah, Jips J., E-mail: jzachariah@chpnet.org [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Ratcliffe, Justin A.; Ruisi, Michael; Puma, Joseph [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Bertrand, Olivier [Quebec Heart and Lung Institute, Quebec (Canada); Kwan, Tak [Mount Sinai Beth Israel Hospital, New York, NY (Israel)
2016-12-15
Objective: To demonstrate the safety and feasibility of the transpedal approach as an alternate arterial access site for iliac artery intervention. Background: The common femoral artery is the traditional access site for the endovascular treatment of iliac artery stenoses. However, this approach is associated with complication rates as high as 2%, including retroperitoneal bleeding which carries high patient morbidity and mortality. Furthermore, the standard femoral approach is associated with longer recovery times and longer time to ambulation which are important considerations especially when performing procedures in an ambulatory setting. Methods: Twelve patients were prospectively followed after treatment for symptomatic iliac artery stenosis via transpedal access. Under ultrasound guidance, one of the pedal arteries was visualized and accessed, and stenting of the iliac arteries were performed as per protocol. The patient was monitored immediately post procedure and clinical follow up was performed at one week and one month later. Results: The average age of the patients was 71 years old. 58% were male. Most patients had Rutherford class III symptoms. Successful stent placement was achieved in all 12 patients via transpedal access. No conversion to femoral access was required. No complications immediately post procedure nor at any time period during follow up were noted. Lower extremity arterial duplex at one month showed patent stents and patent pedal access site vessels in all patients. Conclusion: Transpedal arterial access may be a safe and feasible approach for iliac artery stenting. Given the possible benefits of avoiding femoral artery access, larger studies should be conducted directly comparing the different approaches.
Energy Technology Data Exchange (ETDEWEB)
Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)
2014-05-28
The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.
International Nuclear Information System (INIS)
Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Wang, Chao-Jan; Liu, Shih-Jung; Hung, Kuo-Chun
2014-01-01
The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.
Chua, Su-Kiat; Hung, Huei-Fong
2009-07-01
A 73-year-old man with resistant hypertension and impaired renal function underwent stenting for right renal artery (RRA) stenosis. Two years later, he presented with uncontrolled hypertension and worse renal function. Renal arteriogram revealed RRA stent fracture with in-stent restenosis. Another stent was deployed. Four months later, however, renal arteriogram revealed in-stent restenosis again. This time, balloon angioplasty alone was performed. He had been symptom-free with stable condition at 2-year follow-up. A literature review disclosed six renal artery stent fracture cases, including the present one, who developed in-stent stenosis resulted from stent fracture. Two major anatomy features of renal artery stenosis were suggestive for development of stent fracture: (1) renal artery entrapment by diaphragmatic crus, and (2) mobile kidney with acute angulation at proximal segment of the renal artery. It is important to detect this etiology of renal artery stenosis because stenting in these vessels may contribute to in-stent restenosis or stent fracture. Management of renal artery stent fracture, including endovascular treatment or aortorenal bypass, should be considered on a case-by-case basis in relation to clinical settings. Copyright 2009 Wiley-Liss, Inc.
International Nuclear Information System (INIS)
Dys, Krzysztof; Drelichowska-Durawa, Justyna; Dołega-Kozierowski, Bartosz; Lis, Michał; Sokratous, Kyriakos; Iwanowski, Wojciech; Drelichowski, Stanisław; Witkiewicz, Wojciech
2013-01-01
Treatment of peripheral arterial diseases may be distinguished into conservative and interventional management; the latter is divided into surgical and endovascular procedures. Management of peripheral artery stenosis and occlusion with vascular stents is associated with the risk of late complications such as restenosis, stent fracture or dislocation. A 62-year-old woman with generalized atherosclerosis, particularly extensive in lower limb arteries, was admitted to the Department of Angiology 11 months after having an endovascular procedure performed due to critical ischemia of left lower limb. Because of stent occlusion, a decision to perform angiographic examination of lower limb arteries was made. Examination revealed occlusion of the superficial femoral artery along its entire length, including previously implanted stents. Distal stent was fractured with slight dislocation of the proximal segment. A decision was made to perform mechanical thrombectomy using a Rotarex system followed by a stent-in-stent placement procedure. Follow-up angiography and ultrasound scan performed 24 hours after the procedure revealed a patent vessel with satisfactory blood flow. Nowadays, imaging diagnostics of peripheral artery stenosis involves non-invasive examinations such as ultrasound, minimally invasive examinations such as angio-MRI and MDCT, or invasive examinations such as DSA and IVUS. DSA examinations are used to confirm significant stenosis or occlusion of a vessel, particularly when qualifying a patient for endovascular treatment. Due to their anatomic location, the superficial femoral artery and the popliteal artery are subject to various forces e.g. those exerted by the working muscles. Mechanical thrombectomy and atherectomy are efficient methods of arterial recanalization used in the treatment of acute, subacute or even chronic occlusions or stenosis of peripheral vessels. Frequency of angioplasty and vascular stent implantation procedures is increased in patients
Isolated anomalous origin of the vertebral artery from the common carotid artery.
Kesler, William W; Sabat, Shyamsunder B
2018-04-18
Anomalous origins of the vertebral arteries are uncommon and typically associated with other abnormalities of the great vessels. We present a case of an isolated origin of the right vertebral artery from the ipsilateral common carotid artery detected using magnetic resonance angiography. Such variants can significantly affect endovascular and surgical planning.
Stent grafting of acute hepatic artery bleeding following pancreatic head resection
International Nuclear Information System (INIS)
Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do
2007-01-01
The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)
53. Bilateral ductal stenting for nonconfluent pulmonary arteries in a newborn
Directory of Open Access Journals (Sweden)
K. Al Dhahri
2016-07-01
Full Text Available Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Limited data available for bilateral PDA stenting. Bilateral PDA stenting in nonconfluent pulmonary arteries is challenging procedure but can be considered as an option in the management of complex conditions like this. 12 days old Preterm (36 weeks gestation male baby with birth weight of 2.6 kg developed respiratory distress with severe cyanosis and desaturation upto 50%. Baby was intubated and started on Prostaglandin 0.05 mic/kg/mt. His saturation improved to 80%. Echocardiogram showed complex cyanotic heart disease, Situs ambiguous, dextrocardia, complete unbalanced AV septal defect, pulmonary atresia , nonconfluent small branch pulmonary arteries supplied by the bilateral patent ductus arteriosus (PDA from right aortic arch and all four pulmonary veins form a confluence and drain into superior vena cava(SVC through vertical vein with no obstruction. Baby was taken up for PDA stenting. descending aortogram showed right aortic arch with vertical tortuous duct to right pulmonary artery (RPA and another short duct with acute angle from left subclavian artery to left pulmonary artery (LPA . Both ducti stented with coronary stents. Vertical vein angiogram showed both lungs drain to a confluence and then to SVC via ascending vertical vein with no obstruction. After stenting lung perfusion improved and the baby was stable and maintained 80% saturation on room air. Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Our case is unique with Heterotaxy, TAPVC, Dextrocardia and double ducti. Eventhough bilateral ductal stenting is technically challenging it is successful through femoral artery approach.
Subintimal stent placement in patients with long segment occlusion of the iliac artery
Energy Technology Data Exchange (ETDEWEB)
Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)
2008-01-15
We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.
Clinical application of multislice spiral CT angiography in evaluation of anomalous vertebral artery
International Nuclear Information System (INIS)
Hua Rui; Liu Jun; Zhang Yu
2008-01-01
Objective: To evaluate the diagnostic value of 16-slice spiral computed tomography angiography (MSCTA) in evaluation of anomalous vertebral artery. Methods: MSCTA data from 32 patients with anomalous vertebral artery were retrospectively analyzed. Results: 22 cases had vertebral artery course variation (bended into the C 5 , C 4 or C 3 foramen transversarium), 7 cases had variation in the prevertebral segments of vertebral arteries, 15 patients had unilateral vertebral congenital stenosis, 1 case had double vertebral artery branch, 1 case had vertebral arterial fenestration, and 2 cases had vertebral artery in one side that did not converged upon basilar artery and unilateral vertebral artery formed basilar artery. Conclusion: MSCTA is a useful noninvasive imaging tool for the diagnosis of vertebral artery variations. (authors)
Holzapfel, Gerhard A; Stadler, Michael; Gasser, Thomas C
2005-02-01
Clinical studies have identified factors such as the stent design and the deployment technique that are one cause for the success or failure of angioplasty treatments. In addition, the success rate may also depend on the stenosis type. Hence, for a particular stenotic artery, the optimal intervention can only be identified by studying the influence of factors such as stent type, strut thickness, geometry of the stent cell, and stent-artery radial mismatch with the wall. We propose a methodology that allows a set of stent parameters to be varied, with the aim of evaluating the difference in the mechanical environment within the wall before and after angioplasty with stenting. Novel scalar quantities attempt to characterize the wall changes inform of the contact pressure caused by the stent struts, and the stresses within the individual components of the wall caused by the stent. These quantities are derived numerically and serve as indicators, which allow the determination of the correct size and type of the stent for each individual stenosis. In addition, the luminal change due to angioplasty may be computed as well. The methodology is demonstrated by using a full three-dimensional geometrical model of a postmortem specimen of a human iliac artery with a stenosis using imaging data. To describe the material behavior of the artery, we considered mechanical data of eight different vascular tissues, which formed the stenosis. The constitutive models for the tissue components capture the typical anisotropic, nonlinear and dissipative characteristics under supra-physiological loading conditions. Three-dimensional stent models were parametrized in such a way as to enable new designs to be generated simply with regard to variations in their geometric structure. For the three-dimensional stent-artery interaction we use a contact algorithm based on smooth contact surfaces of at least C-continuity, which prevents numerical problems known from standard facet-based contact
Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna
2002-03-01
A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.
Angioplasty and stent placement in the treatment of radiation-induced arterial injury
International Nuclear Information System (INIS)
Liu Pengcheng; Pierre, P.; Philippe, O.; Danial, C.; Jean-Paul, B.; Cyril, B.; Jean-Pierre, C.; Denis, K.; Helve, R.; Francis, J.
1999-01-01
Objective: Evaluation of therapeutic efficacy and longterm patency of angioplasty and stent for the treatment of radiation induced arterial disease. Methods: PTA was attempted in 18 arterial lesions following irradiation in 14 patients. Thirteen stents were placed in 8 patients to treat occlusion (n = 3), aneurysm (n = 1), residual stenosis (n =2), multiple stenoses (n = 1), and delayed restenosis after previous balloon angioplasty (n = 1). The stents were readily visualized and patency of the stent and the target artery determined with Doppler US and (or) CT in all patients. Results: Interventional procedure was successful in 14 patients of which 8 underwent stent placement for their arterial lesions. Eleven of these patients demonstrated primary patency with relief of clinical symptoms with a mean follow-up of 2 years (range, 8 months -60 months). Clinical improvement was noted for the other patients. Eleven patients underwent PTA once or twice. One patient had PTA four times and three stents were installed, two of which were in the area of the aortic bifurcation, and one in the celiac trunk. another patient also had PTA four times and two stents were placed in the superior mesenteric artery. A stent was implanted in one patient because of PTA induced dissection and occlusion, and the arterial lesion was considered to be cured clinically after a follow-up of 5 years. Conclusions: The results suggested that PTA with single or multiple techniques may be effective immediately in the treatment of arterial lesions caused by radiation and can be considered the first therapeutic option in these cases
Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery
Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris
2017-08-01
Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.
Clinical and radiological evaluation in vertebral artery dissections
Directory of Open Access Journals (Sweden)
Murat Çabalar
2013-04-01
Full Text Available In recent years, vertebral artery dissection (VAD is reported more frequently as a cause of young cerebrovascular accidents. It can occur spontaneously or following a neck manipulation and trauma. The patients were 3 females (mean age: 35±26 years and 7 males (mean age: 37.71±4.96 years. Only 2 patients described neck trauma. Cerebellar findings were prominent in all cases. On radiological investigation, vascular changes of vertebral arteries were detected bilaterally in 2 cases, right in 5 and left in 3 cases. All the cases were treated with anticoagulant therapy and cured but 1 with sequela. Prognosis of vertebral artery dissection is generally good by early diagnosis and treatment. In this article, we reported clinical and radiological properties of 10 vertebral artery dissection cases.
Treatment of a spontaneous intracranial dissecting aneurysm with stent-assisted coil embolization
International Nuclear Information System (INIS)
Irie, Keiko; Negoro, Makoto; Hayakawa, Motoharu; Hayashi, Junichi; Kanno, Tetsuo
2003-01-01
Arterial dissection is now recognized as an important cause of stroke. Most reported dissections involve the extracranial portion of the internal carotid artery (ICA) and vertebral arteries. Spontaneous dissecting aneurysms of the intracranial ICA are uncommon. Endovascular treatment for cerebral aneurysms has become widespread; however, the dissecting aneurysm is still difficult to treat if the parent artery has to be preserved. More recently, stenting has been advocated for use with endosaccular coiling, with the coils held in place by the stent. We herein report a spontaneous intracranial ICA dissecting aneurysm in a 51-year-old woman who was treated using a new technique of combined stent and coils. (orig.)
Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation
International Nuclear Information System (INIS)
Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman; Wichter, Thomas; Grude, Matthias
2003-01-01
The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)
Stent angioplasty for the treatment of symptomatic stenosis of middle cerebral artery
International Nuclear Information System (INIS)
Lu Huisheng; Niu Huiming; Chao Yuanxiang; Li Xiaoning; Wu Dingfeng; Zhang Chenhong; Yang Jie; Zhang Liang
2010-01-01
Objective: To investigate the safety and feasibility of endovascular stent angioplasty in treating symptomatic stenosis of middle cerebral artery. Methods: Endovascular angioplasty with coronary stents was performed in 27 patients with symptomatic stenosis of middle cerebral artery. The clinical results were reviewed and analyzed. Results: Of the total 27 patients, successful placement of the coronary stents was achieved in 24. Angiography immediately after the procedure showed that the stenotic degree of the diseased artery was markedly decreased from preoperative (80 ± 19)% to postoperative (8 ±4)%, the improvement was very obvious. Percutaneous transcatheter angioplasty had to be employed in two cases because of the failure of stent placement. A mean follow-up period of 18 months was carried out. During the following up period no transient cerebral ischemia attack occurred in 25 patients and no newly-developed cerebral infarction in region fed by the responsible vessels occurred either.Re-irrigation cerebral hemorrhage was seen in one patient, which occurred three hours after the placement of the stent. In one case the placed stent fell off and immigrated into the siphon of internal carotid artery, and the displaced stent was took out later with a catching apparatus. In another case re-stenosis occurred six months after the stenting. Conclusion: Percutaneous endovascular stent angioplasty is a safe and effective treatment for symptomatic stenosis of middle cerebral artery, although its long-term results need to be further evaluated. (authors)
Primary stenting as emergency therapy in acute basilar artery occlusion
International Nuclear Information System (INIS)
Spreer, Joachim; Arnold, Sebastian; Klisch, Joachim; Schumacher, Martin; Els, Thomas; Hetzel, Andreas; Huppertz, Hans-Juergen; Oehm, Eckhardt
2002-01-01
In three patients with acute occlusion of the basilar artery intra-arterial fibrinolysis resulted in only partial recanalization and revealed severe stenosis as the underlying cause. Application of micro-stents without previous dilatation resulted in vessel re-opening. Two patients had an excellent clinical outcome. One patient died 10 days after the stroke due to brainstem infarction. Emergency primary stent application may improve the outcome in acute basilar artery occlusion, if intra-arterial thrombolysis fails to re-establish a sufficient flow. (orig.)
International Nuclear Information System (INIS)
Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas
2007-01-01
Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis
Energy Technology Data Exchange (ETDEWEB)
Rohr, A.; Alfke, K.; Doerner, L.; Jansen, O. [UKSH Kiel (Germany). Neurochirurgie Neuroradiologie; Bartsch, T.; Stingele, R. [UKSH Kiel (Germany). Neurologie
2007-10-15
Purpose: Evaluation of the use of covered stents in treating pseudoaneurysms of the cervical and intracranial/extradural carotid artery and determination of the periprocedural and short- to mid-term complication rate. Materials and Methods: 8 patients with 9 spontaneous dissecting aneurysms of the cervical carotid artery - 5 of which were symptomatic - plus one patient with ofthalmoplegia due to an aneurysm of the cavernous carotid artery were studied. While the latter was treated with a PTFE-covered balloon-mounted stainless steel stent (Jostent/Graftmaster), a self-expanding PTFE-covered Nitonol Stent (Symbiot) was used in all other cases. Intervention was performed with local anesthesia. Aspirin and Clopidogrel were both used as antiplatelet drugs. Clinical signs and symptoms and vascular imaging with DS, MR, CT angiography and ultrasound were recorded during patient follow-up, with a mean follow-up period of 14.6 months (4 - 30). Results: We were able to treat 8 out of 10 aneurysms (80 %) using covered stents. The aneurysms were immediately occluded and the associated stenoses of the parent vessel were eliminated. No clinically relevant complications occurred during the procedure or in the follow-up interval. In two cases, elongation of the carotid artery prevented the stent from being positioned over the aneurysm neck. These cases were shown to be stable with the use of antiplatelet drugs. Conclusion: Covered stents can be used in the treatment of pseudoaneurysms of the carotid artery as an alternative to long-term antithrombotic medication or surgery. In our study treatment was effective (80 %) and free of complications in the short- and mid-term follow-up. Possible indications, technique and the use of imaging modalities for patient follow-up are discussed. (orig.)
[Successful correction with stent-graft of coronary artery rupture after angioplasty].
Demin, V V
2003-01-01
Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.
The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation
International Nuclear Information System (INIS)
Huang Mingsheng; Shan Hong; Jiang Zaibo; Li Zhengran; Zhu Kangshun; Guan Shouhai; Qian Jiesheng; Chen Guihua; Lu Minqiang; Yang Yang
2006-01-01
Purpose: This retrospective study was undertaken to evaluate the effectiveness of coronary stent placement in hepatic artery stenosis after orthotopic liver transplantation (OLT). Materials and methods: Of 430 consecutive adult orthotopic liver transplant recipients between November 2003 and September 2005, 17 had hepatic artery stenosis (HAS). Fourteen of them underwent coronary stent placement in the HAS. The technical results, complications, hepatic artery patency and clinical outcome were reviewed. Results: Technical and immediate success was 100%. After a mean follow-up of 159.4 days (range, 9-375 days), all patients obtained patent hepatic arteries except 2 patients occurred hepatic artery restenoses at 26 and 45 days after stent placement, respectively. Kaplan-Meier curve of patency showed cumulated stent patency at 3, 6, and 12 months of 78%, 58% and 45%, respectively. During the follow-up, 8 patients survived, 5 died of septic multiple-organ failure, 1 received retransplantation because of refractory biliary infection. Hepatic artery dissection induced by a guiding catheter occurred in one patient and was successfully treated with a coronary stent. Conclusion: Hepatic artery stenosis after OLT can be successfully treated with coronary stent placement with low complication rate and an acceptable 1-year hepatic artery patency rate
Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey
2018-01-01
Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-termmorbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD. PMID:29470746
Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey
2018-05-01
Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.
Treatment of splenic artery aneurysm with double overlapping bare stents: case report
International Nuclear Information System (INIS)
Kwak, Hyo Sung; Han, Young Min; Jin, Gong Yong
2004-01-01
The traditional treatment of splenic artery aneurysm (SAA) is generally surgery and/or transcatheter arterial embolization, but recently, the treatment of SAA using a stent graft has been reported. However, the acute angle of the celiac axis, as well as the tortuous path of the splenic artery makes the use of stent graft difficult for treatment of aneurysma. We report here a case of SAA treated with the technique of double overlapping metallic stents
Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection
Energy Technology Data Exchange (ETDEWEB)
Mourand, Isabelle [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France); Hopital Gui de Chauliac, Department of Neurology, Service de Neurologie, Montpellier, Cedex 5 (France); Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain [Hopital Gui de Chauliac, Department of Neuroradiology, CHU Montpellier, Montpellier, Cedex 5 (France); Thouvenot, Eric [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France)
2010-02-15
Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS {<=}1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)
International Nuclear Information System (INIS)
Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi
2012-01-01
Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with
Directory of Open Access Journals (Sweden)
Prakash B Billakanti
2016-03-01
Full Text Available La arteria vertebral es una de las arterias que irriga el cerebro. El conocimiento de la anatomía normal y las variantes de la arteria vertebral adquiere importancia en la práctica clínica y la radiología vascular. El origen anómalo de la arteria vertebral del arco de la aorta o cualquiera de las arterias del cuello ha sido reportado por muchos autores. En este informe se presenta una variación del curso prevertebral de la arteria vertebral izquierda. La arteria vertebral tenía su origen habitual en la arteria subclavia con un largo curso prevertebral y entraba en el foramen transversarium de la vértebra CII. El origen y recorrido de la arteria vertebral en el lado derecho fue normal. Clínicamente es importante conocer el origen y curso del segmento prevertebral de la arteria vertebral y las posibles variaciones. El presente informe debería ser de interés para el médico vascular con respecto a las variaciones en el cuello y región torácica, y puede dar idea para dilucidar el mecanismo de desarrollo de la angiogénesis. Vertebral artery is one of the arteries supplying the brain. Knowledge of the normal and variant anatomy of the vertebral artery assumes importance in clinical practice and vascular radiology. Anomalous origins of the vertebral artery from the arch of the aorta or any one of the arteries of the neck have been reported by several authors. In this report a variation of the prevertebral course of the left vertebral artery is being presented. The Vertebral artery had usual origin from the subclavian artery and had a longer prevertebral course to enter the foramen transversarium of the CII vertebra. The origin and course of the vertebral artery on the right side was normal. It is clinically important to know the origin and course of the prevertebral segment of the vertebral artery and possible variations. The present report should be of interest for clinicians with regard to vascular variations in the neck and thoracic
Time-dependent 3D simulations of the hemodynamics in a stented coronary artery
International Nuclear Information System (INIS)
Faik, Isam; Mongrain, Rosaire; Leask, Richard L; Rodes-Cabau, Josep; Larose, Eric; Bertrand, Olivier
2007-01-01
Stenting is becoming the major interventional cardiology procedure worldwide. However restenosis remains a major limitation to the effectiveness of stents. Alterations to the local hemodynamics in the stented segment of the artery could be a potential factor in the development of in-stent restenosis. The characterization of wall shear stress and of blood flow patterns in a stented artery is therefore necessary for a good understanding of the role of hemodynamics in the development of in-stent restenosis. We have used a time-dependent 3D numerical model of a stented coronary artery to study the characteristics of the blood flow and the shear stress distribution. Our results show that the presence of the stent produces significant secondary flow that is limited to an annulus in the near wall region. Low shear stress zones were localized in the vicinity of the struts while the tips of the struts exhibited high values of shear stress. These results support the hypothesis that local hemodynamics may affect the development of in-stent restenosis and could influence the choice of stent geometries for future stent designs
Experimental research of covered stent implanted in canine hepatic artery
International Nuclear Information System (INIS)
Zhou Bing; Liu Linxiang; Li Minghua; Wang Yongli; Cheng Yongde
2007-01-01
Objective: To evaluate the feasibility of success rate of implantation, post-procedure stenosis rate, apposition ability and endothelialization level, etc. for implantation with balloon-expandable covered stent in canine hepatic artery. Methods: 8 adult canines were implanted with balloon-expendable stents covered by expandable poly Teflon ester membrane (e-PTFEM). Follow-up DSA was performed immediately, 2, 4 and 12 wk after the procedure. The canines were sacrificed for histopathologic examination and statistical analysis with correlation of implantation manenvor and angiographic manifestations. Results: 8 cases were all implanted with the covered stents in proper hepatic artery/right hepatic artery successfully; showing good apposition ability and non-opacification of the separated branches. 2 cases showed intraluminal obvious stenosis( > 50%)of the stent at 2 weeks follow-up, so did 3 cases at 12 weeks follow-up, and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization (3 different locations of the sample all manifested full endothelialization), 3 cased manifested partial endothelialization (at least 1 location of the sample didn't show full endothelialization), and the two terminal parts were easier to get endothelialization than the central part. Before and after the stent implantation, hepatic function of all cases didn't demonstrate any obvious changes. Conclusions: Balloon-expandable covered stent can be implanted in canine hepatic artery. successfully, with good apposition ability, full endothelialization, and no influence on hepatic function. (authors)
Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection
International Nuclear Information System (INIS)
Mourand, Isabelle; Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain; Thouvenot, Eric
2010-01-01
Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS ≤1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)
2010-02-15
We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.
International Nuclear Information System (INIS)
Sun, Zhonghua; Chaichana, Thanapong
2010-01-01
We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair
Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography
International Nuclear Information System (INIS)
Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung
2009-01-01
Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of
Factors that affect mass transport from drug eluting stents into the artery wall
Directory of Open Access Journals (Sweden)
Walsh Michael T
2010-03-01
Full Text Available Abstract Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy.
International Nuclear Information System (INIS)
Peregrin, J. H.; Smirova, S.; Koznar, B.; Novotny, J.; Kovac, J.; Lastovickova, J.; Skibova, J.
2008-01-01
The purpose of this prospective study was to evaluate whether stent placement in infrapopliteal arteries is helpful in failed percutaneous transluminal angioplasty (PTA). Infrapopliteal PTA was performed in 70 arteries of 66 patients with chronic critical lower limb ischemia. The group comprised 55 males and 11 females, with an average age of 63.4 (range, 42-82) years. Diabetes mellitus was present in 92.4% of patients. Only the palpable anterior tibial and posterior tibial arteries were evaluated. Stents (Xpert stent; Abbot Vascular, Redwood City, CA, USA) were placed in 16 arteries where PTA was not successful (the failure was defined as residual stenosis >30% after PTA). In 54 arteries simple PTA was performed and was technically successful. Twenty-four nondilated arteries with no significant stenosis served as a comparison group. The 12-month patency rate was evaluated according to a combination of palpation and Doppler ultrasound. In all cases stent placement restored the flow in the artery immediately after unsuccessful PTA. Twelve-month follow-up showed a patency rate of 82% in the PTA group, 78% in the stent group, and 69% in the comparison group. We conclude that stent placement in the case of unsuccessful infrapopliteal PTA changed technical failure to success and restored flow in the dilated artery. At 12-month follow-up the patency rate of infrapopliteal arteries stented for PTA failure did not differ significantly either from nonstented arteries with an optimal PTA result or from a comparison group of nonintervened arteries.
Current global status of carotid artery stent placement.
Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C
1998-05-01
Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.
Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano
2017-06-06
Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion
Usefulness of CT angiography after metallic stent implantation of the internal carotid artery
International Nuclear Information System (INIS)
Yoon, Man Won; Kim, Hyeon Chul; Kim, Jae Kyu; Seo, Jeong Jin; Jeong, Gwang Woo; Kang, Heoung Keun
1999-01-01
To evaluate the usefulness of CT angiography in patients with implantation of metallic stent for stenosed internal carotid artery. Seven patients with atherosclerotic stenosis of the internal carotid artery underwent metallic stent implantation. All were male and their ages ranged from 36 to 69 years. A total of seven stents were placed in the internal carotid artery in five patients and in the carotid bifurcation in two. Spiral CT scans were obtained and CT angiographic images were reconstructed using MPR or curved MPR techniques at a workstation. The interval between CT and conventional angiography did not exceed six days except in one patient, in whom it was 61days. CT and conventional angiography were compared for stent position with respect to the carotid bifurcation, stent deformation, intraluminal filling defect, and luminal caliber and outflow. Luminal patency of the implanted stent was measured according to NASCET(North American Symptomatic Carotid Endarterectomy Trial) criteria, and statistically processed (p>.05). The presence or absence of intrastent thrombus and vascular wall calcification was determined using axial source images. In all patients, CT angiographic findings matched those obtained by conventional angiography. Complications such as migration or deformation of an implanted stent, intraluminal filling defect, change of luminal caliber or outflow of implanted stent were not observed in any patient. In two studies in which Wilcoxon signed rank test was used, degree of stent expansion correlated closely(p=0.237). Axial source images showed that in no patient was an intrastent thrombus present, though in five, vascular wall calcification of internal carotid arteries outside the stent was noted. CT angiography is useful for the assessment of positional change, occlusion, and luminal patency of a stent-implanted internal carotid artery
Functional effects of renal artery stent placement on treated and contralateral kidneys.
Leertouwer, T.C.; Derkx, F.H.M.; Pattynama, P.M.; Deinum, J.; Dijk, L.C. van; Schalekamp, M.A.D.H.
2002-01-01
BACKGROUND: This study examined the effects of stent placement for renal artery stenosis on the function of treated and contralateral kidneys. METHODS: Eighteen patients who underwent stent placement for unilateral renal artery stenosis presenting with hypertension and/or renal failure were studied
Fatic, Nikola; Jaffer, Usman; Ivana, Saicic; Gordana, Globarevic-Vukcevic; Markovic, Dragan; Kostic, Dusan; Davidovic, Lazar
2017-10-01
The clinical spectrum of internal carotid artery occlusion ranges from being a completely asymptomatic occlusion to a devastating stroke or death. The prevalence of asymptomatic internal carotid artery occlusion is unknown, particularly for bilateral occlusion. The distal branches of the external carotid artery anastomose with distal branches of the internal carotid artery provide important sources of collateral circulation to the brain. Stenosis of the external carotid artery with ipsilateral/bilateral internal occlusion may result in ischemic sequelae. Coiling or kinking of the vertebral artery is a rare morphological entity that is infrequently reported because it remains asymptomatic and has no clinical relevance. Currently, there is little evidence to support management strategies for this disease entity and no official recommendations for asymptomatic bilateral carotid artery occlusion. We present a case of a 62-year-old female with asymptomatic bilateral internal carotid artery occlusion, bilateral external carotid artery stenoses, and bilateral kinking of the vertebral artery at the V2 segment, who has been successfully managed conservatively for over 5 years. An individualized approach to management of patients with bilateral internal carotid artery occlusion, especially in combination with external carotid artery stenosis and elongation malformations of the vertebral artery is key to a successful strategy. Copyright © 2017 Elsevier Inc. All rights reserved.
Clinical observation of intraluminal stent angioplasty in the treatment of renal arterial stenoses
International Nuclear Information System (INIS)
Lu Yanwen; Zhang Jian; Huang Xianglong
2002-01-01
Objective: To evaluate the clinical application of intraluminal stent angioplasty (PTRAS) in the treatment of renal arterial stenoses. Methods: A retrospective study was done in 28 patients with renal arterial stenoses. Primary renal artery stenting was performed in 28 consecutive patients (36 renal arteries). Blood pressure, serum creating, the number of anti-hypertensive medications were recorded at 1, 6, 12 month post stent angioplasty respectively. Arterial angiography was also taken 1 year later to evaluate the incidence of restenosis. Results: Technical success rate was 100% achieving in all patients without serious complications. Primary successful patently rate reached 82% (renal artery 86%), secondary successful rate was 89% (renal artery 90%). Systolic and diastolic blood pressure were reduced significantly (P<0.01) at 1,6,12 month after stent angioplasty comparing with baseline and clinical improvement (cured + improved) of hypertension reached 100%, 92.9%, 89.3% respectively. There were no significant differences between serum creatine level and the number of anti-hypertensive medications before and after stent angioplasty. One year later, 14.3% of all patients showed improvement of renal function, 64.3% remained in stabilization and 21.4% fell into deterioration. Angiographic restenosis was found in 3 cases one year after stent angioplasty. Complications included 1 hematoma at puncture site and 3 transient azotaemia. Conclusions: PTRAS can be performed safely with high technical success and beneficial to the majority of patients with hypertension or renal insufficiency and therefore it should be the first choice in treating renal arterial stenoses
International Nuclear Information System (INIS)
Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D.; Zeller, Thomas; Coerper, Stephan; Beckert, Stefan; Balletshofer, Bernd
2007-01-01
The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 ± 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)
Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M
2013-01-01
Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.
Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi
2016-01-01
When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.
The pattern and prevalence of vertebral artery injury in patients with cervical spine fractures
Directory of Open Access Journals (Sweden)
Farzanah Ismail
2013-06-01
Method: A retrospective review of patients who had undergone CTA of the vertebral arteries was undertaken. Reports were reviewed to determine which patients met the inclusion criteria of having had both cervical spine fractures and CTA of the vertebral arteries. Images of patients who met the inclusion criteria were analysed by a radiologist. Results: The prevalence of vertebral artery injury was 33%. Four out of the 11 patients who had vertebral artery injury, had post-traumatic spasm of the artery, with associated thrombosis or occlusion of the vessel. In terms of blunt carotid vertebral injury (BCVI grading, most of the patients sustained grade IV injuries. Four patients who had vertebral artery injury had fractures of the upper cervical vertebrae, i.e. C1 to C3. Fifteen transverse process fractures were associated with vertebral artery injury. No vertebral artery injury was detected in patients who had facet joint subluxations. Conclusion: Patients with transverse process fractures of the cervical spine and upper cervical vertebral body fractures should undergo CTA to exclude vertebral artery injury.
Assessment of coronary artery stent patency by electron-beam CT
International Nuclear Information System (INIS)
Knollmann, Friedrich D.; Felix, Roland; Moeller, Joerg; Gebert, Axel; Bethge, Christian
2004-01-01
Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)
Assessment of coronary artery stent patency by electron-beam CT
Energy Technology Data Exchange (ETDEWEB)
Knollmann, Friedrich D.; Felix, Roland [Department of Radiology, Charite, Campus Virchow-Klinikum, Humboldt-University, Augustenburger Platz 1, 13353, Berlin (Germany); Moeller, Joerg; Gebert, Axel; Bethge, Christian [Department of Cardiology, Juedisches Krankenhaus, Berlin (Germany)
2004-08-01
Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)
Vertebral Artery Dissection Causing Stroke After Trampoline Use.
Casserly, Courtney S; Lim, Rodrick K; Prasad, Asuri Narayan
2015-11-01
The aim of this study was to report a case of a 4-year-old boy who had been playing on the trampoline and presented to the emergency department (ED) with vomiting and ataxia, and had a vertebral artery dissection with subsequent posterior circulation infarcts. This study is a chart review. The patient presented to the emergency department with a 4-day history of vomiting and gait unsteadiness. A computed tomography scan of his head revealed multiple left cerebellar infarcts. Subsequent magnetic resonance imaging/magnetic resonance angiogram of his head and neck demonstrated multiple infarcts involving the left cerebellum, bilateral thalami, and left occipital lobe. A computed tomography angiogram confirmed the presence of a left vertebral artery dissection. Vertebral artery dissection is a relatively common cause of stroke in the pediatric age group. Trampoline use has been associated with significant risk of injury to the head and neck. Patients who are small and/or young are most at risk. In this case, minor trauma secondary to trampoline use could be a possible mechanism for vertebral artery dissection and subsequent strokes. The association in this case warrants careful consideration because trampoline use could pose a significant risk to pediatric users.
Magnetic resonance angiography of the extracranial carotid and vertebral arteries
International Nuclear Information System (INIS)
Akimura, Tatsuo; Saito, Kenichi; Nakayama, Hisato; Kashiwagi, Shiro; Kato, Shoichi; Ito, Haruhide.
1994-01-01
To evaluate the contribution of magnetic resonance angiography (MRA) in the screening study of the extracranial carotid and vertebral arteries using the conventional head and neck coils, 500 consecutive MRAs of the cervical vessels were performed using 1.5 tesla magnetic resonance unit with circularly polarized head coil. The 5 cm-thick imaging plane was placed in coronal fashion including both carotid and vertebral arteries. The imaging sequence was three-dimensional (3D) fast imaging with steady precession (FISP). In 10 patients with failed head coil examination, 10 patients with possible carotid and vertebral diseases and 10 volunteers, the extracranial carotid and vertebral arteries were examined with the Helmholtz neck coil. Both 3D- and 2D-FISP were performed in each case. The imaging plane was placed in oblique sagittal fashion. In 458 out of 500 cases (91.6%), the extracranial carotid and vertebral arteries were successfully depicted using head coil. In 20 patients with high shoulders, the carotid bifurcations were out of range of the head coil. In these cases, carotid bifurcations and the origins of the carotid and vertebral arteries were successfully revealed using a neck coil. To evaluate the stenotic lesions and tortuous vessels, 2D-FISP sequence seemed to be more suitable than 3D-FISP. Compared with conventional angiography, MRA caused overestimation of the degree of stenotic lesions. For screening examination of the extracranial carotid and vertebral arteries, most cases can be evaluated only with the conventional head coil. If depiction of the carotid bifurcation fails and the examination of carotids or vertebrals down to the aortic arch is needed, neck coil examination is required. (author)
The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis
Directory of Open Access Journals (Sweden)
Hiroshi Fujita
2014-12-01
Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.
Stroke prevention by endovascular treatment of carotid and vertebral artery dissections.
Moon, Karam; Albuquerque, Felipe C; Cole, Tyler; Gross, Bradley A; McDougall, Cameron G
2017-10-01
Endovascular intervention for cervical carotid artery dissection (CAD) and vertebral artery dissection (VAD) may be indicated in specific circumstances. To review our institutional experience with endovascular treatment of cervical dissections over the past 20 years to examine indications for treatment, interventional methods, and outcomes. Retrospective review of a prospectively maintained database to identify patients with extracranial dissection who underwent endovascular intervention between January 1996 and January 2016. Demographic data and details of procedures, outcomes, and complications were extracted. Of 116 patients [93 CAD, 23 VAD; mean age 44.9 years (range 5-76 years)], 104 underwent stent placement; 11, coil occlusion of the parent artery; and 1, stenting with contralateral vessel occlusion. The cohorts were well matched for age, sex, dissection etiology, and admission and follow-up modified Rankin Scale (mRS) scores. Patients with CAD had significantly more stent placements (p<0.001), failure of medical therapy (p=0.004), and interventions for enlarging pseudoaneurysms (p=0.01) or thromboembolic events (p=0.004). Patients with VAD had significantly more interventions for traumatic occlusion with recanalization (p<0.001). Dissections were spontaneous (n=67), traumatic (n=36), or iatrogenic (n=13). Traumatic dissections in patients with CAD were associated with poor admission mRS scores (p=0.01). Six of 67 (9.0%) patients with spontaneous dissection reported recent chiropractic manipulation. Mean follow-up was 3.5 years (range 1-146 months). Permanent morbidity/mortality was 3.4%, including two deaths. Over a follow-up period of 364 patient-years, 1 stroke occurred (0.27% per year). At last follow-up, 41 previously disabled patients [CAD, 31/93 (33.3%); VAD, 10/23 (43.5%)] were no longer disabled; no patient reported worsened disability. Patients with CAD and VAD differ significantly in presentation, indications for treatment, and treatment
Stabile, Eugenio; Giugliano, Giuseppe; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitrios; Sannino, Anna; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Rubino, Paolo; Esposito, Giovanni; Tesorio, Tullio
2016-06-12
Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk.
Directory of Open Access Journals (Sweden)
Ersan TatlI
2017-05-01
Full Text Available Introduction: Carotid artery stenting (CAS is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. Aim : To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. Material and methods : All CAS procedures with both closed- and hybrid-cell stents performed at our institution between February 2010 and December 2015 were analyzed retrospectively. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack and myocardial infarction. Periprocedural and 30-day adverse events and internal carotid artery (ICA vasospasm rates were compared between the closed-cell and hybrid-cell stent groups. Results : The study included 234 patients comprising 146 patients with a closed-cell stent (Xact stent, Abbott Vascular (mean age: 68.5 ±8.6; 67.1% male and 88 patients with a hybrid-cell stent (Cristallo Ideale, Medtronic (mean age: 67.2 ±12.8; 68.2% male. There was no significant difference between the groups with respect to periprocedural or 30-day adverse event rates. While there was no difference in terms of tortuosity index between the groups, there was a higher procedural ICA vasospasm rate in the closed-cell stent group (35 patients, 23% compared with the hybrid-cell stent group (10 patients, 11% (p = 0.017. Conclusions : The results of this study showed no significant difference in the clinical adverse event rates after CAS between the closed-cell stent group and the hybrid-cell stent group. However, procedural ICA vasospasm was more common in the closed-cell stent group.
Luminal flow amplifies stent-based drug deposition in arterial bifurcations.
Directory of Open Access Journals (Sweden)
Vijaya B Kolachalama
2009-12-01
Full Text Available Treatment of arterial bifurcation lesions using drug-eluting stents (DES is now common clinical practice and yet the mechanisms governing drug distribution in these complex morphologies are incompletely understood. It is still not evident how to efficiently determine the efficacy of local drug delivery and quantify zones of excessive drug that are harbingers of vascular toxicity and thrombosis, and areas of depletion that are associated with tissue overgrowth and luminal re-narrowing.We constructed two-phase computational models of stent-deployed arterial bifurcations simulating blood flow and drug transport to investigate the factors modulating drug distribution when the main-branch (MB was treated using a DES. Simulations predicted extensive flow-mediated drug delivery in bifurcated vascular beds where the drug distribution patterns are heterogeneous and sensitive to relative stent position and luminal flow. A single DES in the MB coupled with large retrograde luminal flow on the lateral wall of the side-branch (SB can provide drug deposition on the SB lumen-wall interface, except when the MB stent is downstream of the SB flow divider. In an even more dramatic fashion, the presence of the SB affects drug distribution in the stented MB. Here fluid mechanic effects play an even greater role than in the SB especially when the DES is across and downstream to the flow divider and in a manner dependent upon the Reynolds number.The flow effects on drug deposition and subsequent uptake from endovascular DES are amplified in bifurcation lesions. When only one branch is stented, a complex interplay occurs - drug deposition in the stented MB is altered by the flow divider imposed by the SB and in the SB by the presence of a DES in the MB. The use of DES in arterial bifurcations requires a complex calculus that balances vascular and stent geometry as well as luminal flow.
International Nuclear Information System (INIS)
Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko
2013-01-01
Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.
International Nuclear Information System (INIS)
Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko
2008-01-01
We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.
Low-profile stent system for treatment of atherosclerotic renal artery stenosis : The GREAT trial
Sapoval, Marc; Zahringer, Markus; Pattynama, Peter; Rabbia, Claudio; Vignali, Claudio; Maleux, Geert; Boyer, Louis; Szczerbo-Trojanowska, Malgorzata; Jaschke, Werner; Hafsahl, Geir; Downes, Mark; Beregi, Jean Paul; Veeger, Nic; Talen, Aly
PURPOSE: The Palmaz Genesis Peripheral Stainless Steel Balloon Expandable Stent in Renal Artery Treatment (GREAT) Trial was designed to assess the safety and performance of a low-profile stent for the treatment of obstructive renal artery disease by looking at 6-month renal artery patency uniformly
Directory of Open Access Journals (Sweden)
Saito N
2016-03-01
Full Text Available Noboru Saito, Yuhei Mori, Sayaka Uchiyama Terumo Corporation R&D Center, Inokuchi, Nakai-machi, Ashigarakami-gun, Kanagawa, Japan Abstract: The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC, which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion direction of the drug and the biological responses of the artery to drug-eluting stent (DES by comparing the AGC-sirolimus stent and the conventional full-surface coating (CFC sirolimus stent. The study aimed to verify whether the AGC approach was appropriate for the development of a safer DES, minimizing the risks of stent thrombosis due to delayed endothelialization by the drug and distal embolization due to cracking of the coating layer on the hinge parts of the DES on stent expansion. In the in vitro local drug diffusion study, we used rhodamine B as a model drug, and rhodamine B released from the AGC stent diffused predominantly into the abluminal side of the alginate artery model. Conversely, rhodamine B released from the CFC stent quickly spread to the luminal side of the artery model, where endothelial cell regeneration is required. In the biological responses study, the luminal surface of the iliac artery implanted with the AGC-sirolimus stent in a rabbit iliac artery for 2 weeks was completely covered with endothelial-like cells. On the other hand, the luminal surface of the iliac artery implanted with the CFC-sirolimus stent for 2 weeks only showed partial coverage with endothelial-like cells. While thrombosis was observed in two of the three CFC-sirolimus stents, it was observed in only one of the three AGC-sirolimus stents. Taken together, these findings indicate that the designed nonuniform coating (AGC is an appropriate approach to ensure a safer DES. However, the number of studies is limited and a larger study should be conducted to reach a statistically
Timaran, Carlos H; Ohki, Takao; Gargiulo, Nicholas J; Veith, Frank J; Stevens, Scott L; Freeman, Michael B; Goldman, Mitchell H
2003-09-01
Inadequate infrainguinal runoff is considered an important risk factor for iliac stent failure. However, the influence of concomitant infrainguinal arterial reconstruction (CIAR) on iliac stent patency is unknown. This study evaluated the influence of CIAR on outcome of iliac angioplasty and stenting (IAS) in patients with poor distal runoff. Over 5 years (1996 to 2001), 68 IAS procedures (78 stents) were performed in 62 patients with poor distal runoff (angiographic runoff score >or=5). The SVS/AAVS reporting standards were followed to define outcome variables and risk factors. Data were analyzed with both univariate analysis (Kaplan-Meier method [K-M]) and regression analysis (Cox proportional hazards model). Indications for iliac artery stenting were disabling claudication (59%) and limb salvage (41%). Of the 68 procedures, IAS with CIAR was performed in 31 patients (46%), and IAS alone was performed in 37 patients (54%). Patients undergoing IAS with CIAR were older (P =.03) and had more extensive and multifocal iliac artery occlusive disease, with more TASC (TransAtlantic Inter-Society Consensus) type C lesions (P =.03), compared with patients undergoing IAS alone. No other significant differences in risk factors were noted. Runoff scores between patients undergoing IAS with CIAR and those undergoing IAS alone were not significantly different (median runoff scores, 6 [range, 5-8] and 7 [range, 5-9], respectively; P =.77). Primary stent patency rate at 1, 3, and 5 years was 87%, 54%, and 42%, respectively, for patients undergoing IAS with CIAR, and was 76%, 66%, and 55%, respectively, for patients undergoing IAS. Univariate analysis revealed that primary stent patency rate was not significantly different between the 2 groups (K-M, log-rank test, P =.81). Primary graft patency rate for CIAR was 81%, 52%, and 46% at 1, 3, and 5 years, respectively. Performing CIAR did not affect primary iliac stent patency (relative risk, 1.1; 95% confidence interval, 0.49-2.47; P
ORIGINAL ARTICLE The pattern and prevalence of vertebral artery ...
African Journals Online (AJOL)
vertebral artery injury in all patients who have fractures involving the transverse foraminae of the cervical spine, those with facet joint dislocations, and those with fractures involving the first to the third cervical vertebrae. The aim of this study was to determine the pattern and prevalence of vertebral artery injury using CTA in ...
Isoda, H; Takehara, Y; Isogai, S; Takeda, H; Kaneko, M; Nozaki, A; Sun, Y; Foo, T K
1998-08-01
Our goal was to evaluate whether contrast-enhanced three-dimensional MR angiography using the MR Smartprep technique would enable us to obtain arterial-phase MR angiograms of the carotid and vertebral arteries. The study included 35 patients with suspected lesions of the neck in whom the MR Smartprep technique was used for MR angiography performed with a 1.5-T superconducting system. The tracker volume was placed primarily in the middle part of the right common carotid artery. The imaging volume was placed in a coronal direction to include the carotid and vertebral arteries from the aortic arch to the skull base. A centric phase-ordering scheme was used. Imaging times were 20 to 38 seconds for 14 patients and 11 to 16 seconds for 21 patients. By using a smaller tracker volume and an imaging time of less than 16 seconds, we were able to achieve a 100% successful triggering rate and to delineate selectively arterial-phase carotid and vertebral arteries with almost no venous contamination. Contract-enhanced 3-D MR angiography with the MR Smartprep technique was useful for showing arterial-phase carotid and vertebral arteries selectively.
ILIAC-ARTERY URETERAL-FISTULA ASSOCIATED WITH AN INDWELLING URETERAL STENT
ZWEERS, HMM; VANDRIEL, MF; MENSINK, HJA
1991-01-01
We report on a patient with an ureteroiliac artery fistula, which developed after double J stenting. The stent was introduced because of unilateral hydronephrosis 2 months after a Wertheim-Meigs operation preceded by cesium application. The presenting symptom of gross hematuria was initially
International Nuclear Information System (INIS)
Li Zhiming; Tan Lilian; Li Shuxin; Fu Xi; He Weihong; Liu Ke; Huang Yong; Yu Lin
2011-01-01
Objective: To determine the value of 320-detector spiral CT with retrospective ECG gating and editing software for detecting coronary artery in-stent restenosis. Methods: CT scans of 14 patients with coronary artery stnets were retrospectively analyzed. The examinations were performed using a 320-detector spiral CT scanner and retrospective ECG gating combined with ECG editing software. The image quality of reconstructed coronary artery in-stents was compared before and after the editing of synchronously recorded ECG. The paired-sample t test was used for statistical analysis. Results: Before ECG editing, arrhythmia and in-stent artifact resulted in image blurring, missing arterial segments, significant stepladder artifacts or non-visualization of the interior of stents. Of 14 cases before ECG editing, in-stent restenosis was detected in 10 and patency in 3. The coronary artery stent and distal bifurcation were delineated in one patient. After ECG editing, the image quality of coronary artery stents was improved with detection of in-stent restenosis (4 cases) including the one case that not evaluable before ECG editing. The average image quality score before ECG editing (2.14±0.86) was significantly (P<0.001) lower than that after ECG editing (3.07±0.73). Conclusion: Retrospective ECG gating combined with ECG editing of 320-detector spiral CT can reduce the artifacts produced by arrhythmia or in-stent swings and improve the imaging quality of coronary artery stents. (authors)
International Nuclear Information System (INIS)
Rabellino, Martin; García-Nielsen, Luis; Zander, Tobias; Baldi, Sebastián; Llorens, Rafael; Maynar, Manuel
2011-01-01
Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.
Energy Technology Data Exchange (ETDEWEB)
Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)
2011-08-15
Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.
Spontaneous dissecting aneurysm of the extracranial vertebral artery (20 cases)
Energy Technology Data Exchange (ETDEWEB)
Chiras, J; Marciano, S; Vega Molina, J; Touboul, J; Poirier, B; Bories, J
1985-07-01
Spontaneous dissecting aneurysm of the vertebral artery is an infrequent cause of vertebro basilar ischemic strokes. Previously reported cases concern essentially occlusion of the basilar artery. Only 14 cases of spontaneous dissecting aneurysm concern the extracranial vertebral artery among these eight were angiographically documented. In this study based upon 15 patients (20 dissecting aneurysms), the authors discuss etiological factors, such as hypertension or fibromuscular dysplasia: on clinical findings they insist upon the diagnostic value of preliminary symptoms, cervical pain or posterior headaches; the most frequent angiographic appearance was a long and irregular stenosis of one or two segments of the vertebral artery. The prognosis of these aneurysms most often appears favourable in this group.
The pattern and prevalence of vertebral artery injury in patients with ...
African Journals Online (AJOL)
Other important risk factors for vertebral artery injury include facet joint dislocations and fractures of the first to the third cervical vertebral bodies. The aim of this study was to determine the pattern and prevalence of vertebral artery injury on CT angiography (CTA) in patients with cervical spine fractures. Method.
Potential mechanisms of in-stent occlusion in the femoropopliteal artery: an angioscopic assessment.
Ishihara, Takayuki; Iida, Osamu; Okamoto, Shin; Fujita, Masashi; Masuda, Masaharu; Nanto, Kiyonori; Shiraki, Tatsuya; Kanda, Takashi; Tsujimura, Takuya; Okuno, Shota; Yanaka, Koji; Uematsu, Masaaki
2017-10-01
Although stent implantation has become widespread for the treatment of patients with peripheral artery disease with femoropopliteal (FP) lesions, in-stent restenosis, especially in-stent occlusion (ISO), remains as a major concern for refractory recurrence. Furthermore, the mechanisms of ISO in FP lesions have not been well elucidated. We performed angioscopy for 6 lesions (bare-metal stent: 3, drug-eluting stent: 3) from 5 patients (mean age 74 ± 10 years, male 40 %) with ISO in the FP artery immediately after wire-passing or thrombus aspiration. The presence of thrombus as well as the presence and location of organic stenosis were evaluated. Median duration from stent implantation to angioscopic evaluation was 1099.5 (514.5-2272.5) days, while the duration from recurrence of symptoms to angioscopic evaluation was 45 (5.75-60) days. Mixed thrombi were observed in all stents. Organic stenosis was detected at the proximal edge of the stents in 5 lesions. Organic stenosis was observed at the overlapping segment of the stent in one lesion. The distal edge of the stents could be evaluated in 3 lesions, and all of them showed organic stenosis at the site. Mixed thrombi and organic stenosis were observed in all stents. Partial development of organic stenosis in a stent followed by thrombus formation may be the potential mechanism of the development of ISO in the FP artery though the sample size of this study was small and it had no serial angioscopic data so that we should consider it as preliminary one at best.
Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R
2011-01-01
Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363
MR manifestations of vertebral artery injuries in cervical spine trauma
Energy Technology Data Exchange (ETDEWEB)
Yu, Jeong Sik; Chung, Tae Sub; Kim, Young Soo; Cho, Yong Eun; Kang, Byung Chul; Kim, Dong Ik [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)
1996-11-01
To assess the diagnostic efficacy of magnetic resonance (MR) imaging in the detection of a vertebral artery injury occurring from major cervical spine trauma. Conventional MR findings of 63 patients and 63 control subjects were compared to detect a possible change in the vertebral arteries resulted from trauma. Plain films, CT and clinical records were also reviewed to correlate the degree of cervical spine injury with vascular change. Nine cases of absent flow signals in vessel lumen were observed in eight patients and one was observed in the control group. Patients more frequently demonstrated other abnormalities such as intraluminal linear signals (n=3) or focal luminal narrowing (n=9) but there was no statistical significance. There was a close relationship between degree of cord damage and occlusion of the vertebral artery. Conventional MR imaging is useful in the detection of vertebral artery occlusion resulting from cervical spine trauma.
Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam
2016-01-01
Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.
Drug-eluting versus bare-metal stents in large coronary arteries
DEFF Research Database (Denmark)
Kaiser, Christoph; Galatius, Soeren; Erne, Paul
2010-01-01
Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...
Dual-therapy stent technology for patients with coronary artery disease : A great catch?
Kalkman, D.N.
2018-01-01
This thesis investigates the possible advantages of a new stent technology that aims to improve care for patients with coronary artery disease. The COMBO stent (OrbusNeich Medical BV, The Netherlands) contains a dual-therapy stent technology. The stent combines two techniques: a sirolimus-elution
International Nuclear Information System (INIS)
Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.
2004-01-01
Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography
Fan, Zhenmin; Liu, Xiao; Sun, Anqiang; Zhang, Nan; Fan, Zhanming; Fan, Yubo; Deng, Xiaoyan
2017-10-01
Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the possibility, we constructed a patient-specific carotid model with two components of plaques (lipid and calcified plaque) based on MRI images; we numerically compared three different stenting scenarios in terms of von Mises stress (VMS) distribution in the treated arteries, namely, the short stenting (LAM), the medium stenting and the long stenting. The results showed that the short stenting led to more areas with abnormally high VMS along the inner surface of the treated artery with a much higher surface-averaged VMS at the distal end of the stent than both the medium and long stenting. While the VMS distribution in the calcified plaques was similar for the three stenting models, it was quite different in the lipid plaques among the three stenting models. The lipid plaque of the short-stent model showed more volume of the lipid plaque subjected to high VMS than those of the other two models. Based on the obtained results, we may infer that the short stenting (i.e., LAM) may aggravate vascular injury due to high VMS on the artery-stent interaction surface and within the lipid plaque. Therefore, to obtain a better outcome, a longer stent, rather than a short one, might be needed for arterial stenting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Late effects of low-energy gamma-emitting stents in a rabbit iliac artery model
International Nuclear Information System (INIS)
Strauss, Bradley H.; Li, Chris; Whittingham, Heather A.; Tio, Fermin O.; Kutryk, Michael J.B.; Janicki, Christian; Sparkes, John D.; Turnlund, Todd; Sweet, William L.
2002-01-01
Purpose: To determine the long-term dose response of novel low-dose γ-emitting stents in a rabbit iliac artery model. Methods and Materials: Control stents (n=24) and 103 Pd stents 1.0 to 4.0 mCi (n=36) were implanted in the iliac arteries of 30 New Zealand rabbits. Stents were evaluated by intravascular ultrasound (immediately post procedure and before killing) and by histomorphometry. Results: At 26 weeks, 28 rabbits were killed, with no evidence of stent thrombosis. In the body of the stent there was a dose-response relationship with 50% inhibition of intimal hyperplasia at the highest activity compared to control stents (p=0.07) and a significant increase in intimal hyperplasia at the lowest activity (p 103 Pd stents is feasible with reduction of in-stent hyperplasia in a dose-related manner. However, significant narrowing at the stent edges, increased in-stent hyperplasia at lower activities, and incomplete vascular healing with persistence of immature neointima at higher activities are significant limitations
MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types
Directory of Open Access Journals (Sweden)
Matthias C. Burg
2011-01-01
Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.
Renal artery stenting in solitary functioning kidneys: Technical and clinical results
International Nuclear Information System (INIS)
Sahin, Sinan; Cimsit, Cagatay; Andac, Nurten; Baltacioglu, Feyyaz; Tuglular, Serhan; Akoglu, Emel
2006-01-01
Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions
Renal artery stenting in solitary functioning kidneys: Technical and clinical results
Energy Technology Data Exchange (ETDEWEB)
Sahin, Sinan [Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Hospital, Department of Radiology, Istanbul (Turkey)]. E-mail: sinan.sahin@e-kolay.net; Cimsit, Cagatay [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Andac, Nurten [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Baltacioglu, Feyyaz [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Tuglular, Serhan [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey); Akoglu, Emel [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey)
2006-01-15
Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions.
Safety of non-ionic contrast media during renal artery stenting
International Nuclear Information System (INIS)
Ni Jun; Shen Weifeng; Zhang Ruiyan; Zhang Qi; Zhang Xian; Zheng Aifang
2004-01-01
Objective: To evaluate the safety of non-ionic contras media during interventional treatment of renal artery stenosis (RAS). Methods: Fifty four coronary artery disease patients associated with RAS (luminal narrowing > 50%) underwent renal artery stent implantation and percutaneous coronary intervention, only 10 of them with merely renoarterial stenosis undergone renal artery stent implantation. The successful rates of the procedure and complication together with the volumes of contrast media were recorded respectively. And the serum creatine before and 12 hours after the successful procedure were also measured. Results: Both rates of procedural success and complication were similar among the three groups. The serum creatine levels, 12 hours after the procedure, showed no difference in comparing with the baseline. Conclusion: Non-ionic contrast media (Iopamiro 370) could be safely used in patients with RAS. (authors)
Protein losing enteropathy secondary to a pulmonary artery stent
Directory of Open Access Journals (Sweden)
Narayanswami Sreeram
2012-01-01
Full Text Available A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE. He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion. Combined bronchoscopic and catheterization studies during spontaneous breathing confirmed left bronchial stenosis behind the stent, and diastolic systemic ventricular pressure during expiration of 25 mm Hg. We postulate that the stent acts as a valve, against which the patient generates high expiratory pressures, which are reflected in the ventricular diastolic pressure. This may be the cause of PLE.
Decreased Vertebral Artery Hemodynamics in Patients with Loss of Cervical Lordosis.
Bulut, Mehmet Deniz; Alpayci, Mahmut; Şenköy, Emre; Bora, Aydin; Yazmalar, Levent; Yavuz, Alpaslan; Gülşen, İsmail
2016-02-15
BACKGROUND Because loss of cervical lordosis leads to disrupted biomechanics, the natural lordotic curvature is considered to be an ideal posture for the cervical spine. The vertebral arteries proceed in the transverse foramen of each cervical vertebra. Considering that the vertebral arteries travel in close anatomical relationship to the cervical spine, we speculated that the loss of cervical lordosis may affect vertebral artery hemodynamics. The aim of this study was to compare the vertebral artery values between subjects with and without loss of cervical lordosis. MATERIAL AND METHODS Thirty patients with loss of cervical lordosis and 30 controls matched for age, sex, and body mass index were included in the study. Sixty vertebral arteries in patients with loss of cervical lordosis and 60 in controls without loss of cervical lordosis were evaluated by Doppler ultrasonography. Vertebral artery hemodynamics, including lumen diameter, flow volume, peak systolic velocity, end-diastolic velocity, and resistive index, were measured, and determined values were statistically compared between the patient and the control groups. RESULTS The means of diameter (p=0.003), flow volume (p=0.002), and peak systolic velocity (p=0.014) in patients were significantly lower as compared to controls. However, there was no significant difference between the 2 groups in terms of the end-diastolic velocity (p=0.276) and resistive index (p=0.536) parameters. CONCLUSIONS The present study revealed a significant association between loss of cervical lordosis and decreased vertebral artery hemodynamics, including diameter, flow volume, and peak systolic velocity. Further studies are required to confirm these findings and to investigate their possible clinical implications.
MRI and MR angiography of vertebral artery dissection
International Nuclear Information System (INIS)
Mascalchi, M.; Bianchi, M.C.; Mangiafico, S.; Ferrito, G.; Puglioli, M.; Marin, E.; Mugnai, S.; Canapicchi, R.; Quilici, N.; Inzitari, D.
1997-01-01
A review of 4,500 angiograms yielded 11 patients with dissection of the vertebral arteries who had MRI and (in 4 patients) MR angiography (MRA) in the acute phase of stroke. One patient with incidental discovery at arteriography of asymptomatic vertebral artery dissection and two patients with acute strokes with MRI and MRA findings consistent with vertebral artery dissection were included. Dissection occurred after neck trauma or chiropractic manipulation in 4 patients and was spontaneous in 10. Dissection involved the extracranial vertebral artery in 9 patients, the extra-intracranial junction in 1, and the intracranial artery in 4. MRI demonstrated infarcts in the brain stem, cerebellum, thalamus or temporo-occipital regions in 7 patients with extra- or extra-intracranial dissections and a solitary lateral medullary infarct in 4 patients (3 with intracranial and 1 with extra-intracranial dissection). In 2 patients no brain abnormality related to vertebral artery dissection was found and in one MRI did not show subarachnoid haemorrhage revealed by CT. Intramural dissecting haematoma appeared as crescentic or rounded high signal on T1-weighted images in 10 patients examined 3-20 days after the onset of symptoms. The abnormal vessel stood out in the low signal cerebrospinal fluid in intracranial dissections, whereas it was more difficult to detect in extracranial dissections because of the intermediate-to-high signal of the normal perivascular structures and slow flow proximal and distal to the dissection. In two patients examined within 36 h of the onset, mural thickening was of intermediate signal intensity on T1-weighted images and high signal on spin-density and T2-weighted images. MRA showed abrupt stenosis in 2 patients and disappearance of flow signal at and distal to the dissection in 5. Follow-up arteriography, MRI or MRA showed findings consistent with occlusion of the dissected vessel in 6 of 8 patients. (orig.). With 7 figs., 3 tabs
Pulmonary Arterial Stent Implantation in an Adult with Williams Syndrome
International Nuclear Information System (INIS)
Reesink, Herre J.; Henneman, Onno D. F.; Delden, Otto M. van; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul
2007-01-01
We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent implantation. Short-term follow-up showed a good clinical result with excellent patency of the stents but early restenosis of the segments in which only balloon angioplasty was performed. These stenoses were subsequently also treated successfully by stent implantation. Stent patency was observed 3 years after the first procedure
Energy Technology Data Exchange (ETDEWEB)
Baek, Soo Heui; Baek, Hye Jin [Dept. of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)
2014-03-15
We present a rare case of an aberrant right vertebral artery originated from the distal aortic arch. This issue has been incidentally detected on a preoperative CT angiography after a stabbing injury of the cervical spinal cord. Normally, the right vertebral artery originates from the right subclavian artery. Therefore, in this case report we will review the incidence and the embryological mechanism of this aberrant course of the right vertebral artery and we will discuss as well the clinical importance of this variation.
International Nuclear Information System (INIS)
Kim, S.H.; Lee, J.S.; Kwon, O.K.; Han, M.K.; Kim, J.H.
2005-01-01
Purpose: To evaluate the prevalence of proximal vertebral artery stenosis, compared with those of the distal vertebral/basilar artery and extracranial internal carotid artery, in a large population of stroke and non-stroke patients. Material and Methods: Nine-hundred-and-thirty-five patients who underwent high-resolution contrast-enhanced magnetic resonance angiography in a regional general hospital were categorized into six groups based on neurological symptoms and disease: an asymptomatic group (n ∼ 182), a minor symptom group with headache or dizziness (n ∼ 519), a cardiac group with coronary artery steno-occlusive disease (n ∼ 15), a hemorrhagic group with old cerebral hemorrhage (n ∼ 26), an anterior circulation infarct group (n ∼ 121), and posterior circulation infarct group (n ∼ 72). Prevalence of stenosis of the proximal vertebral artery, distal vertebral/basilar artery, and internal carotid artery was analyzed. Results: The prevalence of stenosis of the proximal vertebral artery, distal vertebral/basilar artery, and internal carotid artery was 12.9%, 5.5%, and 7.2%, respectively, in the study population, and rose as the age increased (P <0.0001 for all arteries). The prevalence of stenosis of the proximal vertebral artery, distal vertebral/basilar artery, and internal carotid artery was 3.3%, 0.5%, and.1%, respectively, in the asymptomatic group; 8.3%, 2.1%, and 3.7%, respectively, in the minor symptom group; 13.3%, 6.7%, and 6.7%, respectively, in the cardiac group; 19.2%, 7.7%, and 7.7%, respectively, in the hemorrhagic group; 27.3%, 8.3%, and 25.6%, respectively, in the anterior circulation infarct group; and 44.4%, 36.1%, and 16.7%, respectively, in the posterior circulation infarct group. This increasing tendency of stenosis accordingly was statistically significant ( P <0.0001 for all arteries). Conclusion: The prevalence of proximal vertebral artery stenosis was highest, compared with those of the distal vertebral/basilar artery and
Bilateral Medial Medullary Infarction with Nondominant Vertebral Artery Occlusion.
Zhang, Lei; Zhang, Gui-lian; Du, Ju-mei; Ma, Zhu-lin
2015-09-01
Bilateral medial medullary infarction (MMI) is a rare stroke subtype. Here, we report a case with bilateral MMI caused by nondominant vertebral artery occlusion confirmed by brain digital subtraction angiography and magnetic resonance imaging basi-parallel-anatomical-scanning. We highlight that anterior spinal arteries could originate from a unilateral vertebral artery (VA). Radiologists and neurologists should pay attention to the nondominant VA as bilateral MMI may be induced by occlusion of nondominant VA that supplies the bilateral anteromedial territories of the medulla. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Drenth, Derk Jan
2005-01-01
This thesis describes and discusses the results of a prospective randomized controlled clinical trial comparing percutaneous coronary angioplasty with stenting (stenting) and off-pump coronary artery bypass grafting with a left internal mammary artery (surgery) in patients with a high-grade stenosis
MR diagnosis of cerebellar infarction due to vertebral artery dissection in children
International Nuclear Information System (INIS)
Cheon, J.E.; Kim, I.O.; Kim, W.S.; Yeon, K.M.; Hwang, Y.S.; Wang, K.C.
2001-01-01
Posterior circulation infarction is uncommon in children. We describe the clinical presentation and radiological findings in two children with cerebellar infarction resulting from dissection of the vertebral artery. We emphasize that vertebral artery injury should be considered in a child with acute symptoms and signs of ischaemia in the posterior circulation. MRI and MRA may be helpful in the diagnosis of cerebellar infarction and vertebral artery abnormality. (orig.)
Treatment Challenges of a Primary Vertebral Artery Aneurysm Causing Recurrent Ischemic Strokes
Directory of Open Access Journals (Sweden)
Davide Strambo
2017-01-01
Full Text Available Background. Extracranial vertebral artery aneurysms are a rare cause of embolic stroke; surgical and endovascular therapy options are debated and long-term complication may occur. Case Report. A 53-year-old man affected by neurofibromatosis type 1 (NF1 came to our attention for recurrent vertebrobasilar embolic strokes, caused by a primary giant, partially thrombosed, fusiform aneurysm of the left extracranial vertebral artery. The aneurysm was treated by endovascular approach through deposition of Guglielmi Detachable Coils in the proximal segment of the left vertebral artery. Six years later the patient presented stroke recurrence. Cerebral angiography and Color Doppler Ultrasound well characterized the unique hemodynamic condition developed over the years responsible for the new embolic event: the aneurysm had been revascularized from its distal portion by reverse blood flow coming from the patent vertebrobasilar axis. A biphasic Doppler signal in the left vertebral artery revealed a peculiar behavior of the blood flow, alternately directed to the aneurysm and backwards to the basilar artery. Surgical ligation of the distal left vertebral artery and excision of the aneurysm were thus performed. Conclusion. This is the first described case of NF1-associated extracranial vertebral artery aneurysm presenting with recurrent embolic stroke. Complete exclusion of the aneurysm from the blood circulation is advisable to achieve full resolution of the embolic source.
Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound
International Nuclear Information System (INIS)
Huet, Nicolas; Rodiere, Mathieu; Badet, Michel; Michoud, Marie; Brichon, Pierre-Yves; Ferretti, Gilbert; Thony, Frédéric
2016-01-01
We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.
Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound
Energy Technology Data Exchange (ETDEWEB)
Huet, Nicolas, E-mail: nhuet@chu-grenoble.fr; Rodiere, Mathieu, E-mail: mrodiere@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France); Badet, Michel, E-mail: michel.badet@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, site de Chambéry, Intensive Care Unit (France); Michoud, Marie, E-mail: marie.michoud@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, Site de Chambéry, Department of Radiology (France); Brichon, Pierre-Yves, E-mail: pybrichon@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Thoracic and Vascular Surgery (France); Ferretti, Gilbert, E-mail: gferretti@chu-grenoble.fr; Thony, Frédéric, E-mail: fthony@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France)
2016-05-15
We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.
International Nuclear Information System (INIS)
Cho, W.-S.; Kang, H.-S.; Kim, J.E.; Kwon, O.-K.; Oh, C.W.; Cho, Y.D.; Han, M.H.
2014-01-01
Aim: To investigate the angle changes of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms. Materials and methods: The adjacent parent arterial angles before and after stent-assisted coil embolization were measured in 38 patients with aneurysms of the anterior communicating artery (ACoAA) and 41 patients with bifurcation aneurysms of the middle cerebral artery (MCABA). Variables were analysed in relation to the angle changes. Results: Vascular angles of the parent arteries significantly increased by 27.8° (±18.5°) immediately after stent-assisted coil embolization in 79 cases (p < 0.001), with 25.7° (±14.8°) in ACoAA and 29.7° (±21.4°) in MCABA, respectively. In 51 (64.6%) cases with follow-up angiography (mean interval 13.5 ± 4.1 months), vascular angles increased by 27.2° (±17.1°) immediately after treatment and further increased by 20.7° (±14.3°) at the last follow-up (all p < 0.001). More acute pre-stent angles of the parent arteries correlated with greater post-stent angle changes (p = 0.006). Younger age tended to be inversely related to post-stent angle changes (p = 0.091). Conclusion: Stent placement during coil embolization induced significant changes in the aneurysm–parent artery relationship. Further study is needed to elicit the association between angle change of the parent arteries and aneurysmal stability after coil embolization
Clinical characteristics of unruptured vertebral artery dissections presenting with headaches
International Nuclear Information System (INIS)
Nakamura, Homare; Mizuniwa, Yoshitaka; Kouno, Takao; Nakayama, Hirofumi; Furuya, Yu; Taguchi, Yoshio
2011-01-01
We reviewed 13 cases of patients with unruptured dissections of the vertebral artery who were treated at our hospital after presenting with headaches. We identified 13 patients who had headache alone at the time of onset and who were diagnosed as having vertebral artery dissection using three-dimensional CT, MRI, MR angiography (MRA), or angiography from November 2007 to October 2009. Primary radiographic investigations showed the 'pearl and string' sign in two cases, dilatation in eight, and the string sign alone in three cases. Following initial conservative treatment, 11 cases exhibited radiographic improvement, but two cases underwent surgical treatment because of progressive vertebral artery dissection. A definitive diagnosis was made using primary investigations in nine cases and dynamic changes on radiographic investigations in four cases. The headache was located posteriorly in all cases, but some patients had mild headaches. Clinicians need to be aware of the possibility of vertebral artery dissection even if the headache is mild at onset. Radiographic investigations are important for a definitive diagnosis and in deciding whether to intervene surgically. (author)
Directory of Open Access Journals (Sweden)
JA Mitchell
2009-06-01
Full Text Available Blood flow to the hindbrain, via the paired vertebral arteries, must be uncompromised for adequate neurological functioning of its vital centres. Therefore, it would seem unlikely that the intracranial vertebral artery would need to vasoconstrict, thus reducing its blood flow. In order to investigate the existence and location of a noradrenaline-mediated constrictor mechanism in the wall of the intracranial vertebral artery, transverse sections of ten baboon and ten monkey vessels were stained with sucrose-potassium phosphate-glyoxylic acid (counterstained with malachite-green. This method allows the visualisation of catecholaminergic nerves when the sections are exposed to ultraviolet light. In this study of primate vascular tissue, however, none of the monkey or baboon vertebral artery sections showed the presence of noradrenergic nerves in the tunica media – tunica adventitia junction or penetrating the tunica media of the arteries. These findings indicate that the intracranial vertebral artery does not have a neurogenic vasomotor function in primates.
Shida, Takuya; Umezu, Mitsuo; Iwasaki, Kiyotaka
2018-06-01
We analyzed the adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents for the treatment of iliac venous thromboembolism and investigated their relationships with the anatomical features of the iliac vein, to gain insights into the development of a better iliac vein stent. Reports of adverse events following the use of stents in the iliac vein were retrieved from the Manufacturer and User Facility Device Experience (MAUDE) database that contain suspected device-associated complications reported to the Food and Drug Administration. Data from 2006 to 2016 were investigated. The literature analysis was also conducted using PubMed, Cochrane Library, EMBASE, and Web of Science focusing on English articles published up to 4 October 2016. The analysis of 88 adverse events from the MAUDE database and 182 articles from the literature revealed that a higher number of adverse events had been reported following the use of arterial stents in the iliac vein compared to CE-marked iliac vein stents. While stent migration and shortening were reported only for the arterial stents, stent fracture and compression occurred regardless of the stent type, even though a vein does not pulsate. A study of the anatomical features of the iliac vein implies that bending, compression, and kink loads are applied to the iliac vein stents in vivo. For designing, developing, and pre-clinical testing of stents intended for use in the iliac vein, the above mechanical load environments induced by the anatomical features should be considered.
International Nuclear Information System (INIS)
Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.
2003-01-01
We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA
Conformally integrated stent cell resonators for wireless monitoring of peripheral artery disease
Viswanath, Anupam; Green, Scott Ryan; Kosel, Jü rgen; Gianchandani, Yogesh B.
2013-01-01
This paper presents the design and in vitro evaluation of magnetoelastic sensors intended for wireless monitoring of tissue accumulation in peripheral artery stents. The sensors, shaped like stent cells, are fabricated from 28-μm thick foils
International Nuclear Information System (INIS)
Gweon, Hye Mi; Suh, Sang Hyun; Won, Jong Yun; Lee, Do Yun; Kim, Sam Soo
2008-01-01
We wanted to evaluate the effectiveness of stent placement on the superior mesenteric artery as a treatment for chronic mesenteric ischemia. Seven patients (mean age: 55 years, age range: 43-66 years) with chronic mesenteric ischemia were enrolled between March 2000 and September 2003. All the patients underwent pre-procedure contrast enhanced computerized tomography to evaluate for occlusion or stenosis of the mesenteric arteries and they then underwent an angiographic procedure. A balloon-expandable metal stent was placed in the superior mesenteric artery, and this was combined with balloon angioplasty and thrombolysis. We evaluated the angiographic and procedural success after the procedures. Angiographic and procedural success was obtained in 100% of the patients and the clinical symptoms improved in 100% of the patients. The patency at 6-months and 1-year was 85% and 71%, respectively. The mean follow-up period was 12 months (range: 1-25 months). During the follow-up period, ischemic symptoms recurred in 2 patients, and restenosis in a stent was confirmed with angiography; one patient was successfully treated by stent placement in the celiac artery and the other patient died due to extensive mesenteric thrombosis. For the treatment of chronic mesenteric ischemia, percutaneous stent placement on the superior mesenteric artery showed a favorable result and it was an effective alternative to surgery for the high-risk patients
Clinical experience of cerebral protection with balloon occlusion during carotid artery stenting
International Nuclear Information System (INIS)
Jaeger, H.J.; Mathias, K.D.; Drescher, R.; Bockisch, G.; Hauth, E.; Demirel, E.; Gissler, H.M.; Witten/Herdecke Univ.
2001-01-01
Purpose: To asses the technical feasibility and the results of cerebral protection with the GuardWire Plus Temporary Occlusion and Aspiration System during carotid artery stenting for high-grade stenosis. Patients and Methods: In 20 patients 20 carotid artery stenoses were treated with stent placement under cerebral protection. A contralateral carotid occlusion was an exclusion criteria for the use of the protection device. In all cases only aspiration, but no flushing was used before deflation of the occlusion balloon. In 17 of 20 patients diffusion-weighted (DW-)MRT imaging of the brain was performed before and 24 hours after the procedure. Results: The stent implantation was successfully performed in all patients. In 3 patients neurologic symptoms occurred during the occlusion time. In these 3 patients the symptoms immediately disappeared after deflation of the balloon. In one case there was dilatation of the internal carotid artery at the site of the balloon inflation. In 3 of the 17 DW-MR images new ipsilateral cerebral lesions, in one case a new contralateral lesion occurred after the procedure. Conclusions: The cerebral protection procedure is technically feasible. The occlusion of the internal carotid artery was not tolerated by all patients. The DW-MR imaging demonstrated cerebral lesions indicating the occurrence of cerebral microemboli during the procedure. Further investigations are necessary to determine if the use of the cerebral protection device will improve the results of the carotid artery stenting for high-grade stenoses. (orig.) [de
International Nuclear Information System (INIS)
Kim, Han-Soo; Chan, Rosanna C.; Kollum, Marc; Au, Arthur; Tio, Fermin O.; Yazdi, Hamid A.; Ajani, Andrew E.; Waksman, Ron
2001-01-01
Background: The major limitation of coronary stenting remains in-stent restenosis, due to the development of neointimal proliferation. Radioactive stents have demonstrated the ability to reduce this proliferation in the healthy nonatherosclerotic porcine animal model. However, inhibition of tissue proliferation in the in-stent restenotic lesion in a porcine model is not well characterized. The objective of this study was to examine the efficacy and safety of the 32 P radioactive stent for the treatment of in-stent restenosis in a double stent injury model of the porcine coronaries. Methods and Materials: Eighteen coronary arteries in 9 pigs underwent nonradioactive stent (8 mm in length) implantation. Thirty days after the initial stent implantation, a 32 P radioactive stent (18 mm in length) with an activity of 0 and 18 μCi was implanted to cover the initial stent. The swine were killed 30 days after the second stent implantation. Histomorphometric analysis was performed for vessel area (VA), stent strut area (SSA), intimal area (IA), and lumen area (LA). Results: Injury scores, VA, SSA, and LA were similar among the control and radiated groups. Neointimal formation was significantly reduced after placement of radioactive stents as compared to control in both the overlapped (0.93±0.12 vs. 1.31±0.51 mm 2 , p 2 , p 32 P radioactive stents may be safe and effective in reducing neointimal formation leading to in-stent restenosis. Longer follow-up will be required to examine whether these positive findings can be maintained
Odontogenic Pain as the Principal Presentation of Vertebral Artery Pseudoaneurysm; a Case Report
Directory of Open Access Journals (Sweden)
Marco Zenteno
2015-07-01
Full Text Available Dissection of the vertebral artery is an important but rare cause of cerebrovascular accidents. Here we report a 48-year-old man with toothache since 4 days before who presented to the emergency department with neck pain and final diagnosis of dissecting right vertebral artery pseudoaneurysm. To our knowledge, this maybe the first report of odontogenic pain as the first manifestation of vertebral artery pseudoaneurysm in the literatures.
Kissing stenting of aorto-ostial lesions in juxtaposed renal arteries
Hasija, Pradeep; Chadha, Davinder; Kalra, Ravi
2014-01-01
Percutaneous angioplasty with or without stenting has become an established procedure for treatment of renal artery stenosis for control of hypertension or progressive renal dysfunction. Anatomic variation of renal arteries is common with dual blood supply of unilateral kidney noted in almost 25% of the general population. Renal angioplasty of these anatomic variants of renal arteries is challenging. We present an unusual case of juxtaposed renal arteries with aorto-ostial lesion where direct...
Complications in percutaneous transluminal stenting for carotid artery stenosis
International Nuclear Information System (INIS)
Li Shenmao; Miao Zhongrong; Zhu Fengshui; Ji Xunming; Jiao Liqun; Qi Jianshu; Ling Feng
2007-01-01
Objective: To discuss the complications of endovascular stenting for carotid artery stenosis. Methods: Cerebral vascular angiography and cervical Doppler sonography were performed in 648 patients with carotid artery stenosis. Emboli-protected device was used in 365 patients and none in 283 patients. Results: All 648 patients were technically successful (100%). Symptoms disappeared or improved in 78.7% patients. Slow heart rate during operation existed in 26.4% patients. Embolism caused by dislodgment of emboli occurred in 5 patients, 3 of them recovered after treatment and 2 had unilateral dyskinesias. Intracranial hemorrhage occurred in 3 patients. Stroke or death within 30 days after operation occurred in 6 patients(1.24%). 322 patients (77.8%)were followed up. Restenosis occurred in 17 patients(3.3%). Conclusion: Percutaneous transluminal stenting is a safe option for carotid artery stenosis. Correct evaluation of clinical and angiographic data before operation, together with normative manipulation and nursing during and after operation are the key points to avoid complications. (authors)
Manunga, Jesse M; Oderich, Gustavo S
2012-08-01
To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.
Relationship between vertebral artery blood flow in different head positions and vertigo.
Araz Server, Ela; Edizer, Deniz Tuna; Yiğit, Özgür; Yasak, Ahmet Görkem; Erdim, Çağrı
2018-01-01
To identify the vertebral artery blood flow in different head positions in patients with positional vertigo with no specific diagnosis. Patients with history of vestibular symptoms associated with changes in head position were enrolled into the study. Healthy volunteers were evaluated as control group. Doppler ultrasonography examination of the cervical segment of the vertebral arteries was performed under three different head positions: (i) supine position, (ii) head hyperextended and rotated to the right side and (iii) head hyperextended and rotated to the left side. In the study group, right and left vertebral artery blood flow was significantly lower in the ipsilateral hyperextended position compared to standard supine position (respectively p = .014; p = .001), but did not differ significantly when compared between the standard supine and contralateral hyperextended positions (respectively = .959; p = .669). In the control group, left and right vertebral artery blood flow did not differ significantly when the head was hyperextended to the right or left sides compared to standard supine position (p > .05). Our data demonstrated that the etiology of vestibular complaints in patients with undiagnosed positional vertigo might be related to impairment in vertebral artery blood flow according to head positions.
International Nuclear Information System (INIS)
Zheng Yanbo; Jiang Wenjin; Liu Sheng; Song Xuepeng; Sheng Qirui
2006-01-01
Objectives: To assess the safety and efficacy of percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of iliofemoral arterial atherosclerotic occlusive diseases. Methods From April 1999 to August 2004, 13 cases of iliofemoral arterial occlusions were recanalized with contact thrombolytic therapy combined with guide wire mechanical recanalization method, followed by angioplasty and stent placement. A total of 25 self-expanding Wallstents were deployed. All patients were followed up by means of duplex ultrasound, angiography, or both. Results: All 13 cases were successfully recanalized, with technical successful rate of 100%. Available follow-up for all patients from 8 months-5 years (mean 26.2 months) included one patient undergoing again with successful contact thrombolysis because of early thrombosis; another patient with recurrent symptoms at 19 month after operation undertaking surgical bypass because of later reocclusion; all of the rest stents showing patency by the end of the study. Conclusions: Contact thrombolysis combined with guide wire mechanical recanalization for iliofemoral arterial occlusion is safe and effective, whereas PTA and stent placement would have the nearly same efficacy for the disease with mild injury and low restenosis. (authors)
High-dose external beam irradiation inhibits neointima formation in stented pig coronary arteries
International Nuclear Information System (INIS)
Verheye, Stefan; Coussement, Patrick K.; Salame, Mahomed Y.; Fallahi, Payam; Cui Jianhua; Chronos, Nicolas A.F.; King, Spencer B.; Crocker, Ian R.; Robinson, Keith A.
2001-01-01
Purpose: To evaluate high-dose external beam irradiation (EBRT) in a pig coronary stent preparation because low and intermediate-dose EBRT failed to show inhibition of neointima formation in stented animal models. Methods and Materials: Thirty-five stents were implanted in the coronary arteries of 17 pigs. Seven pigs were exposed to a single dose of 21 Gy EBRT immediately after stenting. Ten stented, nonirradiated pigs served as controls. After 4 weeks, the study arteries and myocardium were examined by light and scanning electron microscopy. Results: Compared with controls, 21 Gy EBRT resulted in a larger lumen area (7.57±1.67 mm 2 vs. 4.00±1.63 mm 2 , p 2 vs. 3.36±2.26 mm 2 , p<0.001) and a smaller maximal intimal thickness (0.16±0.09 mm vs. 0.68±0.31 mm, p<0.001). Unresorbed intramural hemorrhages and adherent mural thrombi were present in the irradiated vessels, which also showed incomplete re-endothelialization. The irradiated hearts demonstrated diffuse interstitial and perivascular inflammation and fibrosis. Conclusions: EBRT at 21 Gy to the entire heart significantly inhibited neointima formation in stented pig coronary arteries but also resulted in incomplete re-endothelialization, myocardial inflammation, and fibrosis. Improvements in localization and delivery techniques are required to allow clinical implementation of this technique
Wingspan stent for symptomatic M1 stenosis of middle cerebral artery
International Nuclear Information System (INIS)
Guo Xinbin; Ma Nan; Hu Xiaobo; Guan Sheng; Fan Yimu
2011-01-01
Objective: Stent placement for intracranial atherosclerotic stenosis has become an alternative treatment technique; however, stent placement for middle cerebral artery (MCA) stenosis remains a technical and clinical challenge. Our purpose was to assess the safety and feasibility of Wingspan stent for patients with symptomatic M1 stenosis, and its initial effect on prevention of ischemic events. Methods: Fifty-three cases with recurrent symptomatic MCA stenosis resistant to medical therapy treated by self-expanding stent were reviewed retrospectively (average 58 ± 18.5 years old, 19 women). All patients underwent angioplasty and stenting with the Gateway balloon–Wingspan stent system, and advised follow-up with DSA or TCD at 6th month. Results: Patients had an average stenosis ratio of 76.5 ± 15.4% prior to the treatment. Of the 53 patients, the technical success rate was 98.1% as a whole (52/53). The mean degree of stenosis reduced from (76.5 ± 15.4)% to (18.2 ± 11.3)%. Complications associated with the procedure include subarachnoid hemorrhage (1.89%) and occlusion (3.78%) occurred. During a follow-up of 6 months, there was no recurrence of transient ischemic attack or stroke in 52 cases with successful stenting. Cerebral hemodynamics of MCA using transcranial Doppler monitoring were at normal level (<120 cm/s) in 41 follow-up patients. The follow up angiography at 6 month post-procedure was conducted in 32 patients and showed good patency in stented vessels. Conclusions: Wingspan stent for symptomatic stenosis of middle cerebral artery is a safe and feasible procedure. It improves clinical outcome in the intermediate follow up, but its long-term effect remains to be further evaluated.
DEFF Research Database (Denmark)
Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov
2012-01-01
Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case...... report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While...... the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor....
Intravascular stenting in the superior mesenteric artery for chronic abdominal angina.
Busquet, J
1997-11-01
Abdominal angina is an early clinical expression of occlusive mesenteric arterial insufficiency, a condition that requires aggressive treatment to prevent intestinal infarction. We report a case of chronic mesenteric ischemia in a young polyvascular man who had symptoms of abdominal angina. An aortic angiogram revealed a significant ostial stenosis of the superior mesenteric artery (SMA) associated with an occlusion of the inferior mesenteric artery. After predilation of the ostial portion of the SMA, significant residual stenosis remained. A balloon-expandable Palmaz P154 stent was deployed, restoring adequate luminal dimensions and blood flow. The patient was discharged after 2 days and remains asymptomatic at 5 months. Intraluminal stenting for treatment of mesenteric ischemia represents a viable alternative to surgical revascularization in selected cases.
DEFF Research Database (Denmark)
Mangione, Fernanda Marinho; Biering-Sørensen, Tor; Nochioka, Kotaro
2017-01-01
OBJECTIVES: To compare mid-term outcomes between patients undergoing proximal left anterior descending artery (LAD) percutaneous coronary intervention (PCI) with second generation drug-eluting stent (DES) or bare-metal stent (BMS). BACKGROUND: PCI with BMS and first-generation DES have shown to b...
Agadzhanian, N A; Kupriianov, S V
2008-06-01
The investigation was intended to study the role ofbaroreceptors ofhemodynamically isolated zone of vertebral arteries in regulation of peripheral veins tonus, arterial pressure and external respiration. Pressure decrease in this vascular reflexogenic zone led to reflex responses of increase in femoral vein tonus, elevation of blood pressure level and stimulation of external respiration. The opposite reflex responses of cardio-respiratory functional system to initial pressure activation of vertebral arteries baroreceptors are observed. Basing on generalization of our own findings and similar physiological and morphological researches of other authors, it is established that afferentation from the vertebral artery zone is a reflexogenic factor of somatic muscles' veins tonus regulation. These reflexes of capacity vessels tonic activity changes are part of cardio-respiratory responses of maintaining the tissue gaseous exchange.
A case of traumatic intracranial vertebral artery injury presenting with life-threatening symptoms
Directory of Open Access Journals (Sweden)
Kishi S
2012-04-01
Full Text Available Seiji Kishi1, Kenji Kanaji2, Toshio Doi1, Tadashi Matsumura21Department of Nephrology, Tokushima University Hospital, Kuramoto-cho Tokushima, 2Department of General Internal Medicine, Rakuwakai Otowa Hospital, Otowachinji-cho Yamashina-ku Kyoto, JapanAbstract: Traumatic intracranial vertebral artery injury is a relatively rare but potentially fatal disease. We present a case of a 63-year-old man who presented with sudden onset of loss of consciousness after hitting his head. After immediate resuscitation, he showed quadriplegia and absence of spontaneous breathing. Brain and cervical spine magnetic resonance imaging revealed an atlantoaxial subluxation, fractured C2 odontoid process, left vertebral artery occlusion, and bilateral extensive ischemia in the medulla oblongata and high cervical spinal cord. Digital subtraction angiography demonstrated left vertebral artery dissection just below the level of vertebral body C2.Keywords: vertebral artery dissection, brainstem infarction, bilateral spinal cord infarction, neck trauma
Valve-Like and Protruding Calcified Intimal Flap Complicating Common Iliac Arteries Kissing Stenting
Directory of Open Access Journals (Sweden)
George S. Georgiadis
2015-01-01
Full Text Available Endovascular therapy for iliac artery chronic total occlusions is nowadays associated with low rates of procedure-related complications and improved clinical outcomes, and it is predominantly used as first-line therapy prior to aortobifemoral bypass grafting. Herein, we describe the case of a patient presenting with an ischemic left foot digit ulcer and suffering complex aortoiliac lesions, who received common iliac arteries kissing stents, illustrating at final antegrade and retrograde angiograms the early recognition of a blood flow obstructing valve-like calcified intimal flap protruding through the stent struts, which was obstructing antegrade but not retrograde unilateral iliac arterial axis blood flow. The problem was resolved by reconstructing the aortic bifurcation at a more proximal level. Completion angiogram verified normal patency of aorta and iliac vessels. Additionally, a severe left femoral bifurcation stenosis was also corrected by endarterectomy-arterioplasty with a bovine patch. Postintervention ankle brachial pressure indices were significantly improved. At the 6-month and 2-year follow-up, normal peripheral pulses were still reported without intermittent claudication suggesting the durability of the procedure. Through stent-protruding calcified intimal flap, is a very rare, but existing source of antegrade blood flow obstruction after common iliac arteries kissing stents.
Drug-eluting stent implantation for the percutaneous treatment of vertebro-basilar arterial stenosis
International Nuclear Information System (INIS)
Ma Rujun; Liu Jianmin; Huang Haiqing; Hong Bo; Xu Yi; Zhao Wenyuan; Zhao Rui; Chen Jun
2006-01-01
Objective: To evaluate the early results and mid-term outcomes following angioplasty of vertebro-basilar arterial stenosis with drug-eluting stents. Methods: All of the patients presented with recurrent TIA or ceretral infarction with >50% stenoses in vertebro-basilar arteries, and having failure in maximal medical therapy. All of the lesions were treated with primary stenting under local or general anesthesia and followed by continual anticoagulant therapy of clopidogrel and aspirin together with clinical follow-up and vascular imagings. Results: Of 28 stenoses (27 patients), 27 lesions were successfully treated with implantation of 24 Cypher stents, 2 Taxus stents and one Firebird stent. The mean stenotic severity reduced from (74 ± 6.7)% to (8.7 ± 4.4)%. Two patients had inchemic events relating to penetration vascular obstruction. During 2-14 months follow-up, the patients were clinically asymptomatic with no recurrent TIA/stoke. Angiographic follow-up was obtained in 14 patients at a mean of 7.2 months. Proximal restenosis (<50%) occurred in one patient (3.3%), and corrected with restenting, while others were free of intra-stent restenoses. Conclusion: Using DES in cerebrovascular stenosis is safe and effective with lowing the risk of intra-stent restenosis in comparison with bare stent. Further study for long term efficiency is still in need. (authors)
Carotid Artery Stenting Successfully Prevents Progressive Stroke Due to Mobile Plaque
Directory of Open Access Journals (Sweden)
Masahiro Oomura
2015-05-01
Full Text Available We report a case of progressive ischemic stroke due to a mobile plaque, in which carotid artery stenting successfully prevented further infarctions. A 78-year-old man developed acute multiple infarcts in the right hemisphere, and a duplex ultrasound showed a mobile plaque involving the bifurcation of the left common carotid artery. Maximal medical therapy failed to prevent further infarcts, and the number of infarcts increased with his neurological deterioration. Our present case suggests that the deployment of a closed-cell stent is effective to prevent the progression of the ischemic stroke due to the mobile plaque.
International Nuclear Information System (INIS)
Rist, Carsten; Nikolaou, Konstantin; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.; Flohr, Thomas
2006-01-01
The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen. (orig.)
Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus
2017-09-01
To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.
International Nuclear Information System (INIS)
Sommer, A.; Neff, W.; Schwartz, A.
1998-01-01
We report a 41-year-old woman with embolic stroke of the mid-pons attributed to embolism from vertebral artery dissection. Angiography revealed an occluded artery on one side and an incidental pseudoaneurysm of the midcervical portion of the vertebral artery on the other. After 3 months of warfarin therapy control angiography showed complete occlusion of the pseudoaneurysm. We discuss therapeutic choices and review the literature. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Jeong, Hee Seok [Dept. of Radiology, Gyeongsang National University Hospital, Jinju (Korea, Republic of); Shin, Tae Beom [Dept. of Diagnostic Radiology, Kimhae Jung Ang Hospital, Kimhae (Korea, Republic of); Hwang, Jae Cheol [Dept. of Radiology, Ulsan Hospital, Ulsan (Korea, Republic of); Bae, Jae Ik [Dept. of Radiology, Ajou University Hospital, Suwon (Korea, Republic of); Kim, Chang Won [Dept. of Radiology, Busan National University Hospital, Busan (Korea, Republic of)
2012-01-15
To evaluate the effectiveness of interventional management for delayed and massive hemobilia secondary to arterial erosion self expandable metallic stent (SES) in with biliary duct malignancy. Over 8-year period, eight patients who suffered from delayed massive hemobilia after SES placement for malignant biliary obstruction as palliative procedure, were included. The mean period between SES placement and presence of massive gastrointestinal hemorrhage was 66.5 days (15-152 days), pancreatic cancer (n = 2), Klatskin tumor (n = 2), common bile duct cancer (n = 2), intrahepatic cholangiocarcinoma (n = 1), and gastric cancer with ductal invasion (n = 1). Angiographic findings were pseudoaneurysm (n = 6), contrast extravasation (n = 1) and arterial spasm at segment (n = 1). Six patients underwent embolization of injured vessels using microcoils and N-butyl cyanoacrylate. Two patients underwent stent graft placement at right hepatic artery to prevent ischemic hepatic damage because of the presence of portal vein occlusion. Massive hemobilia was successfully controlled by the embolization of arteries (n = 6) and stent graft placement (n = 2) without related complications. The delayed massive hemobilia to arterial erosion metallic biliary stent is rare this complication be successfully treated by interventional management.
Stenting for peripheral artery disease of the lower extremities: an evidence-based analysis.
2010-01-01
In January 2010, the Medical Advisory Secretariat received an application from University Health Network to provide an evidentiary platform on stenting as a treatment management for peripheral artery disease. The purpose of this health technology assessment is to examine the effectiveness of primary stenting as a treatment management for peripheral artery disease of the lower extremities. CONDITION AND TARGET POPULATION Peripheral artery disease (PAD) is a progressive disease occurring as a result of plaque accumulation (atherosclerosis) in the arterial system that carries blood to the extremities (arms and legs) as well as vital organs. The vessels that are most affected by PAD are the arteries of the lower extremities, the aorta, the visceral arterial branches, the carotid arteries and the arteries of the upper limbs. In the lower extremities, PAD affects three major arterial segments i) aortic-iliac, ii) femoro-popliteal (FP) and iii) infra-popliteal (primarily tibial) arteries. The disease is commonly classified clinically as asymptomatic claudication, rest pain and critical ischemia. Although the prevalence of PAD in Canada is not known, it is estimated that 800,000 Canadians have PAD. The 2007 Trans Atlantic Intersociety Consensus (TASC) II Working Group for the Management of Peripheral Disease estimated that the prevalence of PAD in Europe and North America to be 27 million, of whom 88,000 are hospitalizations involving lower extremities. A higher prevalence of PAD among elderly individuals has been reported to range from 12% to 29%. The National Health and Nutrition Examination Survey (NHANES) estimated that the prevalence of PAD is 14.5% among individuals 70 years of age and over. Modifiable and non-modifiable risk factors associated with PAD include advanced age, male gender, family history, smoking, diabetes, hypertension and hyperlipidemia. PAD is a strong predictor of myocardial infarction (MI), stroke and cardiovascular death. Annually, approximately
Liu, Ya-min; Qin, Hao; Zhang, Bo; Wang, Yu-jing; Feng, Jun; Wu, Xiang
2016-02-01
Both open and closed loop self-expandable stents were used in carotid artery stenting (CAS) for carotid bifurcation stenosis. We sought to compare the efficacy of two types of stents in CAS. The data of 212 patients treated with CAS (42 and 170 cases implanted with closed and open loop stents, respectively) for carotid bifurcation stenosis and distal filtration protection devices were retrospectively analyzed. Between closed and open loop stents, there were no significant differences in hospitalization duration, NIHSS score before and after the treatment, stenosis at 12th month, and cumulative incidence of primary endpoint events within 30 days or from the 31st day to the 12th month; while there were significant differences in hemodynamic changes and rate of difficulty in recycling distal filtration protection devices. Use of open vs. closed loop stents for carotid bifurcation stenosis seems to be associated with similar incidence of complications, except for greater rate of hemodynamic changes and lower rate of difficulty in recycling the distal filtration protection devices.
Liu, Jian; Jing, Linkai; Zhang, Ying; Song, Ying; Wang, Yang; Li, Chuanhui; Wang, Yanmin; Mu, Shiqing; Paliwal, Nikhil; Meng, Hui; Linfante, Italo; Yang, Xinjian
2017-01-01
Intracranial vertebral artery dissecting aneurysms (VADAs) tend to recur despite successful stent-assisted coil embolization (SACE). Hemodynamics is useful in evaluating aneurysmal formation, growth, and rupture. Our aim was to evaluate the hemodynamic patterns of the recurrence of VADA. Between September 2009 and November 2013, all consecutive patients with recurrent VADAs after SACE in our institutions were enrolled. Recurrence was defined as recanalization and/or regrowth. We assessed the hemodynamic alterations in wall shear stress (WSS) and velocity after the initial SACE and subsequently after retreatment of the aneurysms that recurred. Five patients were included. After the initial treatment, 3 patients showed recanalization and 2 showed regrowth. In the 2 patients with regrowth, the 2 original aneurysms maintained complete occlusion; however, de novo aneurysm regrowth was confirmed near the previous site. Compared with 3 recanalized aneurysms, the completely occluded aneurysms showed high mean reductions in velocity and WSS after initial treatment (velocity, 77.6% vs. 57.7%; WSS, 74.2% vs. 52.4%); however, WSS remained high at the region near the previous lesion where the new aneurysm originated. After the second retreatment, there was no recurrence in any patient. Compared with the 3 aneurysms that recanalized, the 4 aneurysms that maintained complete occlusion showed higher reductions in velocity (62.9%) and WSS (71.1%). Our series indicated that hemodynamics might have an important role in recurrence of VADAs. After endovascular treatment, sufficient hemodynamic reduction in aneurysm dome, orifice, and parent vessel may be one of the key factors for preventing recurrence in VADAs. Copyright © 2016 Elsevier Inc. All rights reserved.
Assessment Of Coronary Arterial Stents By Multislice-CT Angiography
International Nuclear Information System (INIS)
Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.
2003-01-01
Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more
Wang, Xiaofei; Wang, Zhigang; Ji, Yong; Ding, Xuan; Zang, Yizheng; Wang, Chengwei
2017-11-01
To investigate the safety and effectiveness of recanalization in non-acute occlusion of intracranial internal carotid arteries using the flexible Enterprise self-expanding stent. From June 2014 to June 2016, 12 consecutive patients with non-acute occlusion of intracranial internal carotid arteries received endovascular recanalization with Enterprise stenting. All patients received medication for anti-platelet aggregation therapy before and after the operation. The perioperative complications and recanalization efficacy were evaluated with the modified Rankin scoring system and digital subtraction angiography (DSA) follow-up, respectively. Endovascular recanalization was successfully performed in 10 out of 12 patients with Enterprise stenting. Stent implantation following balloon dilatation failed in one patient because the lumen diameter was too small. Another recanalization failed because the guide wire could not pass through the occlusion. No perioperative mortality was observed. One case of acute thrombosis and one case of intraoperative carotid spasm occurred, but these were resolved with thrombolytic therapy by microcatheter exposure treatment and antispasmodic medications, respectively. DSA follow-up in seven patients revealed no re-occlusion. One stroke event occurred in the 10 patients who completed the follow-up. A meaningful improvement in the modified Rankin score during follow-up was suggested by Wilcoxon signed-rank test results. The Enterprise stent was shown to be safe and efficient in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion. However, the long-term outcomes need to be further investigated. Copyright © 2017 Elsevier B.V. All rights reserved.
Duplication of the vertebral artery: report of two cases and review of the literature
International Nuclear Information System (INIS)
Goddard, A.J.P.; Annesley-Williams, D.; Guthrie, J.A.; Weston, M.
2001-01-01
Duplication of the vertebral artery is rare. We report two cases in which it was an incidental finding. In the first, duplication of the right vertebral artery was demonstrated by magnetic resonance angiography (MRA) and conventional angiography. The second patient had duplication of the right vertebral artery demonstrated by MRA. We discuss the origin of this abnormality, its radiological implications and its potential clinical significance are discussed. (orig.)
Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.
Mahfoud, Felix; Tunev, Stefan; Ruwart, Jennifer; Schulz-Jander, Daniel; Cremers, Bodo; Linz, Dominik; Zeller, Thomas; Bhatt, Deepak L; Rocha-Singh, Krishna; Böhm, Michael; Melder, Robert J
2014-12-01
In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA. We report marked blood pressure reduction after RDN in a patient with resistant hypertension who underwent previous stenting. Subsequently, radiofrequency ablation was investigated within the stented segment of porcine RA, distal to the stented segment, and in nonstented RA and compared with stent only and untreated controls. There were neither observations of thrombus nor gross or histological changes in the kidneys. After radiofrequency ablation of the nonstented RA, sympathetic nerves innervating the kidney were significantly reduced, as indicated by significant decreases in sympathetic terminal axons and reduction of norepinephrine in renal tissue. Similar denervation efficacy was found when RDN was performed distal to a renal stent. In contrast, when radiofrequency ablation was performed within the stented segment of the RA, significant sympathetic nerve ablation was not seen. Histological observation showed favorable healing in all arteries. Radiofrequency ablation of previously stented RA demonstrated that RDN provides equally safe experimental procedural outcomes in a porcine model whether the radiofrequency treatment is delivered within, adjacent, or without the stent struts being present in the RA. However, efficacious RDN is only achieved when radiofrequency ablation is delivered to the nonstented RA segment distal to the stent. © 2014 American Heart Association, Inc.
Pediatric congenital vertebral artery arteriovenous malformation
International Nuclear Information System (INIS)
Shownkeen, Harish; Chenelle, Andrew G.; Origitano, Thomas C.; Bova, Davide
2003-01-01
Vertebral arteriovenous fistulas are rare in children and the congenital form has been seldom reported in the literature. Prior to using endovascular therapy techniques, only surgery was the main treatment. The most common endovascular treatment is through the use of detachable balloons. This report describes the clinical and radiological findings of a congenital vertebral artery fistula in a 20-month-old child. Balloons could not be safely employed; therefore, embolization was performed with Guglielmi detachable microcoils. We review the history and treatment of these lesions, their clinical presentation, and imaging features, including their outcome, with particular attention to the pediatric population. (orig.)
Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy
Directory of Open Access Journals (Sweden)
Leoncio L. Kaw, Jr
2006-10-01
Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.
Efficacy of Carotid Artery Stenting by the Universal Protection Method.
Goto, Shunsaku; Ohshima, Tomotaka; Kato, Kyozo; Izumi, Takashi; Wakabayashi, Toshihiko
2018-04-18
To avoid distal plaques embolization during carotid artery stenting, we developed Universal Protection Method that combined the use of a proximal common carotid artery balloon, an external carotid artery balloon, and a distal internal carotid artery filter, with continuous flow reversal to the femoral vein. Herein, we assessed the efficacy of the Universal Protection Method by comparing stenting outcomes before and after its introduction. We assessed outcomes for 115 cases before and 41 cases after the Universal Protection Method was adopted (non-Universal Protection Method and Universal Protection Method groups, respectively). We then compared procedure details, magnetic resonance imaging (within 48 hours after the procedure), intraprocedural complications, and postoperative stroke rates. Ischemic stroke was not observed in the Universal Protection Method group, but 1 major stroke and 2 minor strokes were observed in the non-Universal Protection Method group. High-intensity areas were seen in 6 (15.0%) and 49 (42.6%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively (P = .001). Contrastingly, intraprocedural complications were observed in 9 (22.5%) and 21 (18.3%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively. Among these intraprocedural complication cases, high-intensity areas were observed in 1 case (11.1%) in the Universal Protection Method group and in 15 cases (71.4%) in the non-Universal Protection Method group. Universal Protection Method is a safe technique that is applicable to all patients undergoing carotid artery stenting, irrespective of individual risk factors. Notably, the incidence rates of both distal embolization and unexpected intraprocedural complications are low. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Shanmugalingam, Renuka; Reza Pour, Nina; Chuah, Siang Chye; Vo, Thi Mong; Beran, Roy; Hennessy, Annemarie; Makris, Angela
2016-07-16
Arterial dissection is a rare complication of pregnancy and puerperium. There have been reports of aortic, coronary and cervical artery dissection in association with preeclampsia, however, vertebral artery dissection is rarely reported particularly in the antenatal setting in the presence of a Hypertensive Disorder of Pregnancy (HDP).The general annual incidence of symptomatic spontaneous cervicocephalic arterial dissection is 0.0026 % and a data registry reported that 2.4 % of these occurred in the post-partum period. The actual incidence of vertebral artery dissection in HDP is unknown as the current literature consists of case series and reports only with most documenting adverse outcomes. Given the presence of collateral circulation, unilateral vertebral artery dissections may go unrecognised and may be more common than suspected. We present a case series of four patients with vertebral artery dissection in association with HDP, two of which occurred in the antenatal setting and two in the post-partum setting. All our patients had favourable outcome with no maternal neurological deficit and live infants. Our discussion covers the proposed pathophysiology of vertebral artery dissection in HDP and the management of it. Our case series highlights the need to consider VAD an important differential diagnosis when assessing pregnant women with headache and neck pain particularly in the context of HDP.
Kądziela, Jacek; Januszewicz, Andrzej; Prejbisz, Aleksander; Michałowska, Ilona; Januszewicz, Magdalena; Florczak, Elżbieta; Kalińczuk, Łukasz; Norwa-Otto, Bożena; Warchoł, Ewa; Witkowski, Adam
2013-01-01
The aim of our study was to determine a potential relationship between resting translesional pressures ratio (Pd/Pa ratio), renal fractional flow reserve (rFFR) and blood pressure response after renal artery stenting. Thirty five hypertensive patients (49% males, mean age 64 years) with at least 60% stenosis in angiography, underwent renal artery stenting. Translesional systolic pressure gradient (TSPG), Pd/Pa ratio (the ratio of mean distal to lesion and mean proximal pressures) and hyperemic rFFR - after intrarenal administration of papaverine - were measured before stent implantation. Ambulatory blood pressure measurements (ABPM) were recorded before the procedure and after 6 months. The ABPM results were presented as blood pressure changes in subgroups of patients with normal (≥ 0.9) vs. abnormal (renal artery stenting. Median changes of 24-h systolic/diastolic blood pressure were comparable in patients with abnormal vs. normal Pd/Pa ratio (-4/-3 vs. 0/2 mm Hg; p = NS) and with abnormal vs. normal rFFR (-2/-1 vs. -2/-0.5 mm Hg, respectively). Physiological assessment of renal artery stenosis using Pd/Pa ratio and papaverine- induced renal fractional fl ow reserve did not predict hypertension response after renal artery stenting.
One Year Clinical Outcomes of Renal Artery Stenting: The Results of ODORI Registry
International Nuclear Information System (INIS)
Sapoval, M.; Tamari, I.; Goffette, P.; Downes, M.; Senechal, Q.; Fanelli, F.; Reimer, P.; Negaiwi, Z.; Cassin, P. De; Heye, S.; Korobov, V.; Tsetis, D.; Abada, H.
2010-01-01
The safety, efficacy and long term clinical benefits of renal artery revascularization by stenting are still a matter of debate. The aim of our study was to define the safety and efficacy of renal artery stenting with the Tsunami peripheral stent (Terumo Corporation, Tokyo, Japan). The ODORI was a prospective, multicentre registry which enrolled 251 consecutive patients, (276 renal arteries) in 36 centres across Europe. The primary endpoint was acute procedural success defined as <30% residual stenosis after stent placement. Secondary endpoints included major adverse events, blood pressure control, serum creatinine level, and target lesion revascularization (TLR) at 6 and 12 months. Patients were 70 ± 10 years old, 59% were male, 33% had diabetes, and 96% hypertension. The main indications for renal stent implantation were hypertension in 83% and renal salvage in 39%. Direct stent implantation was performed in 76% of the cases. Acute success rate was 100% with residual stenosis of 2.5 ± 5.4%. Systolic/diastolic blood pressure decreased from a mean of 171/89 at baseline to 142/78 mmHg at 6 months (p < 0.0001 vs. baseline), and 141/80 mmHg at 12 months (p < 0.0001 vs. baseline). Mean serum creatinine concentration did not change significantly in the total population. However, there was significant improvement in the highest tercile (from 283 μmol/l at baseline to 205 and 209 μmol/l at 6 and 12 months respectively). At 12-months, rates of restenosis and TLR were 6.6 and 0.8% respectively. The 12 month cumulative rate of all major clinical adverse events was 6.4% while the rate of device or procedure related events was 2.4%. In hypertensive patients with atherosclerotic renal artery stenosis Tsunami peripheral balloon-expandable stent provides a safe revascularization strategy, with a potential beneficial impact on hypertension control and renal function in the highest risk patients.
International Nuclear Information System (INIS)
Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong
2010-01-01
Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.
Energy Technology Data Exchange (ETDEWEB)
Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)
2013-11-01
Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.
Dual-artery stenting of a type III single coronary artery from right aortic sinus
Directory of Open Access Journals (Sweden)
Shivanad Patil
2015-12-01
Full Text Available A single coronary artery presenting with stenosis in two of the three vessels arising from a common ostium is a rare anomaly Lipton et al. proposed a classification, which was modified by Yamanaka and Hobbs. In our case, a single coronary artery was giving rise to the LAD, left circumflex (LCx, and the right coronary artery (RCA. There was 80% stenosis in the ostium of the LCx. The RCA in the mid and distal segment had stenosis of 80% and 70%, respectively. We were able to successfully stent the three stenotic segments.
International Nuclear Information System (INIS)
Xing Ming; Yang Pengfei; Huang Qinghai; Zhao Wenyuan; Hong Bo; Xu Yi; Liu Jianmin
2012-01-01
Objective: To preliminarily evaluate the feasibility, safety and efficacy of stent placement for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation. Methods: Eleven patients with wide-necked aneurysms located at internal carotid artery bifurcation, who were encountered during the period from Jan. 2004 to Dec. 2010 in hospital, were collected. A total of 16 intracranial aneurysms were detected, of which 11 were wide-necked and were located at internal carotid artery bifurcation. The diameters of the aneurysms ranged from 2.5 mm to 18 mm. Individual stent type and stenting technique was employed for each patient. Follow-up at 1, 3, 6 and 12 months after the procedure was conducted. Results: A total of 11 different stents were successfully deployed in the eleven patients. The stents included balloon expandable stent (n=1) and self-expanding stent (n=10). According to Raymond grading for the immediate occlusion of the aneurysm, grade Ⅰ (complete obliteration) was obtained in 4, grade Ⅱ (residual neck) in 2 and grade Ⅲ (residual aneurysm) in 5 cases. No procedure-related complications occurred. At the time of discharge, the modified Rankin score was 0-1 in the eleven patients. During the follow-up period lasting for 1-108 months, all the patients were in stable condition and no newly-developed neurological dysfunction or bleeding observed. Follow-up examination with angiography (1-48 months) showed that the aneurysms were cured (no visualization) in 4 cases, improved in 2 cases and in stable condition in one case. Conclusion: For the treatment of wide-necked aneurysms located at internal carotid artery bifurcation, stent implantation is clinically feasible, safe and effective. Further studies are required to evaluate its long-term efficacy. (authors)
Energy Technology Data Exchange (ETDEWEB)
Sommer, A.; Neff, W.; Schwartz, A. [Department of Neurology, Klinikum Mannheim, Medical Faculty, University of Heidelberg, Theodor-Kutzer-Ufer 1, D-68132 Mannheim (Germany)
1998-04-01
We report a 41-year-old woman with embolic stroke of the mid-pons attributed to embolism from vertebral artery dissection. Angiography revealed an occluded artery on one side and an incidental pseudoaneurysm of the midcervical portion of the vertebral artery on the other. After 3 months of warfarin therapy control angiography showed complete occlusion of the pseudoaneurysm. We discuss therapeutic choices and review the literature. (orig.) With 4 figs., 8 refs.
Acute Carotid Artery Stent Thrombosis Due to Dual Antiplatelet Resistance
International Nuclear Information System (INIS)
Köklü, Erkan; Arslan, Şakir; Yüksel, İsa Öner; Bayar, Nermin; Koç, Pınar
2015-01-01
Carotid artery stenting (CAS) is a revascularization modality that is an alternative to carotid endarterectomy. The efficacy of CAS in primary and secondary prevention from ischemic stroke has been demonstrated in various trials. Acute thrombosis of CAS is a rare complication that can lead to dramatic and catastrophic consequences. We discuss a case of acute CAS thrombosis in a patient who had previously undergone successful CAS. CAS was performed in a 73-year-old man who had had dysarthria lasting 2 weeks with 95 % stenosis in his left internal carotid artery. An acute cerebrovascular event resulting in right-sided hemiplegia developed 24 h after the procedure. Computed tomographic carotid angiography revealed complete occlusion of the stent with thrombus. The cause of stent thrombosis was thought to be antiaggregant resistance to both acetylsalicylic acid and clopidogrel. The most important cause of acute CAS thrombosis is inadequate or ineffective antiaggregant therapy. Evaluating patients who are candidates for CAS for acetylsalicylic acid and clopidogrel resistance may preclude this complication
Fibrosing Mediastinitis: Successful Stenting of the Pulmonary Artery
Directory of Open Access Journals (Sweden)
Rennae Thiessen
2008-01-01
Full Text Available Fibrosing mediastinitis is a rare benign condition, which can cause compression of the pulmonary or systemic vessels, tracheobronchial tree, coronary arteries or esophagus, leading to disabling clinical symptoms and even death. The case of a 26-year-old woman who presented with dyspnea is described. She was found to have 80% stenosis of the right pulmonary artery secondary to fibrosing mediastinitis. The stenosis was managed successfully with an endovascular Palmaz-Schatz stent, and the patient remains symptom-free 10 years later.
Complication rate in unprotected carotid artery stenting with closed-cell stents
International Nuclear Information System (INIS)
Tietke, Marc W.K.; Kerby, Tina; Alfke, Karsten; Riedel, Christian; Rohr, Axel; Jensen, Ulf; Jansen, Olaf; Zimmermann, Phillip; Stingele, Robert
2010-01-01
The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable. (orig.)
Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia
International Nuclear Information System (INIS)
Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.
2009-01-01
Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.
Energy Technology Data Exchange (ETDEWEB)
Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)
2012-12-15
We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.
International Nuclear Information System (INIS)
Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko
2012-01-01
We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.
Energy Technology Data Exchange (ETDEWEB)
Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)
2003-09-15
Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 +- 39.7 ml/min for the right side and 127.6 +- 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 +- 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 +- 59.19 ml/min in male, and 217.28 +- 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.
International Nuclear Information System (INIS)
Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol
2003-01-01
Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 ± 39.7 ml/min for the right side and 127.6 ± 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 ± 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 ± 59.19 ml/min in male, and 217.28 ± 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.
Energy Technology Data Exchange (ETDEWEB)
Mehta, Vimal, E-mail: drvimalmehta@yahoo.co.in; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay [G.B. Pant Institute of Postgraduate Medical Education and Research (India)
2016-01-15
We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory.
International Nuclear Information System (INIS)
Mehta, Vimal; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay
2016-01-01
We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory
Arisha, Mohammed J; Hsiung, Ming C; Ahmad, Amier; Nanda, Navin C; Elkaryoni, Ahmed; Mohamed, Ahmed H; Yin, Wei-Hsian
2017-06-01
Ostial lesions represent a challenging clinical scenario and percutaneous intervention (PCI) of left main coronary artery ostial lesions has been associated with postintervention complications, including protrusion of deployed stents into a sinus of Valsalva or aortic root. We report a case of stent protrusion into the aortic root following aorto-ostial left main coronary artery PCI, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Specifically, 3DTEE confirmed the presence of stent protrusion by allowing clear visualization of the stent scaffold, in addition to characterizing the relationship between the stent and surrounding structures. © 2017, Wiley Periodicals, Inc.
Directory of Open Access Journals (Sweden)
Michael Raum
2018-06-01
Full Text Available We report a case of a 9-year-old female who required surgical treatment and resuscitation after severe transoesophageal bleeding of a right aberrant subclavian artery (RASA. Bleeding of this RASA was caused by a mechanical irritation due to an oesophageal stent. The stent was placed weeks before to dilate the oesophagus after accidental ingestion of a caustic agent. Although conservative management of benign oesophageal stenosis in children is highly recommended, there are still some major complications to be considered. To avoid erosion of aberrant subclavian artery vascular rings and slings, as described in several case reports, these vessels should be excluded by computed tomography (CT or magnetic resonance imaging (MRI scans before placement of oesophageal stents. This case suggests that management of caustic ingestion in children is still a major challenge in paediatric surgical departments. Keywords: Paediatric surgery, Chemical Burn, Oesophageal stenosis, Oesophageal stenting, Vascular abnormalities, Right aberrant subclavian artery
Closed cervical spine trauma associated with bilateral vertebral artery injuries
Kloen, P.; Patterson, J. D.; Wintman, B. I.; Ozuna, R. M.; Brick, G. W.
1999-01-01
Bilateral vertebral artery injuries in closed cervical spine injuries are uncommon, but early recognition and treatment are important to prevent neurological deterioration. A case of bilateral vertebral injuries in a 35-year-old motor vehicle accident victim is presented, and the current literature
International Nuclear Information System (INIS)
Yamamoto, Hiromichi; Kuwayama, Naoya; Hayashi, Nakamasa; Kubo, Michiya; Endo, Shunro
2011-01-01
This study evaluated the usefulness of computed tomography (CT) angiography for the detection of high-risk aortas for carotid artery stenting (CAS). We investigated changes in the treatment method and modifications of endovascular techniques according to the information from CT angiography. CT angiography using three-dimensional and multi-planar reconstruction was performed in 43 consecutive patients with carotid artery stenoses intended to undergo CAS. Two neurosurgeons evaluated the images and estimated the risk and difficulties of CAS. CT angiography clearly depicted the entire aorta, the supra-aortic vessels, and the ilio-femoral arteries in all patients. Abnormal vascular findings were found in 17 patients. High-risk aortic lesions for CAS were detected in 5 patients, including thick aortic plaques with thrombi in 2. We changed the treatment strategy from CAS to carotid endarterectomy (CEA) in these 2 patients. CT angiograms proved very useful in evaluating the approach routes of CAS in 12 patients. One patient had dissecting aneurysm of the thoracic aorta and another had aberrant right vertebral artery. In these two, the treatment strategy was changed from CAS to CEA. The treatment method was changed in 4 patients in total. CT angiography is useful for the detection of high-risk aortas for CAS and for the evaluation of safe approaches to the carotid artery. (author)
Short-term safety and efficacy of the biodegradable iron stent in mini-swine coronary arteries
Institute of Scientific and Technical Information of China (English)
WU Chao; QIU Hong; HU Xiao-ying; RUAN Ying-mao; TIAN Yi; CHU Yan; XU Xin-lin
2013-01-01
Background To overcome the drawbacks of permanent stents,biodegradable stents have been studied in recent years.The bioabsorbable polymer vascular scaffold (BVS) was the first bioabsorbable stent to undergo clinical trials,demonstrating safety and feasibility in the ABSORB studies.Iron can potentially serve as the biomaterial for biodegradable stents.This study aimed to assess the short-term safety and efficacy of a biodegradable iron stent in mini-swine coronary arteries.Methods Eight iron stents and eight cobalt chromium alloy (VISION) control stents were randomly implanted into the LAD and RCA of eight healthy mini-swine,respectively.Two stents of the same metal base were implanted into one animal.At 28 days the animals were sacrificed after coronary angiography,and histopathological examinations were performed.Results Histomorphometric measurements showed that mean neointimal thickness ((0.46±0.17) mm vs.(0.45±0.18)mm,P=0.878),neointimal area ((2.55±0.91) mm2 vs.(3.04±1.15) mm2,P=0.360) and percentage of area stenosis ((44.50±11.40)% vs.(46.00±17.95)%,P=0.845) were not significantly different between the iron stents and VISION stents.There was no inflammation,thrombosis or necrosis in either group.The scanning electron microscopy (SEM) intimal injury scores (0.75±1.04 vs.0.88±0.99,P=0.809) and number of proliferating cell nuclear antigen (PCNA) positive staining cells were not significantly different between the two groups.The percentage of neointimal coverage by SEM examination was numerically higher in iron stents than in VISION stents ((84.38±14.50)% vs.(65.00±22.04)%,P=0.057),but the difference was not statistically significant.Iron staining in the tissue surrounding the iron stents at 28 days was positive and the vascular wall adjacent to the iron stent had a brownish tinge,consistent with iron degradation.No abnormal histopathological changes were detected in coronary arteries or major organs.Conclusions The biodegradable iron stent has
Stent placement with the monorail technique for treatment of mesenteric artery stenosis.
Schaefer, Philipp J; Schaefer, Fritz K W; Hinrichsen, Holger; Jahnke, Thomas; Charalambous, Nikolas; Heller, Martin; Mueller-Huelsbeck, Stefan
2006-04-01
To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.
Is anomalous origin of the left vertebral artery indeed a rare finding ...
African Journals Online (AJOL)
We present a pictorial review of anomalous origin of the left vertebral artery observed in 5 patients imaged in our after-hours trauma radiology unit within a period of 7 days. We raise the question of whether the incidence of anomalous origin of the left vertebral artery quoted in the radiology literature as 5% is really that low, ...
Energy Technology Data Exchange (ETDEWEB)
Lee, Deok Hee; Hur, Seung Ho; Kim, Hyeon Gak; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)
2000-03-01
Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.
International Nuclear Information System (INIS)
Jeong, Won Gi; Yoon, Woong; Yim, Nam Yeol; Jung, Min Young; Jung, Se Hee; Kang, Heoung Keun
2013-01-01
To investigate clinical outcomes following the emergent carotid artery stenting for treatment of acute ischemic stroke. Twenty-eight consecutive patients with acute stroke due to atherosclerotic steno-occlusive diseases of extracranial internal carotid artery underwent emergent carotid artery stenting. Of these, 23 patients had tandem intracranial arterial occlusions. Extracranial carotid stenting was successful in all patients. From the 13 patients who underwent intracranial recanalization procedures, successful recanalization occurred in 84.6% (11/13). 57% of patients (16/28) had a good clinical outcome (modified Rankin Scale 0-2) after 3 months. Patients with successful intracranial/extracranial recanalization had a significantly higher rate of good outcome than those without recanalization after 3 months (75% vs. 33%, p = 0.027). Patients without intracranial tandem occlusions had a more favorable clinical outcome than those with intracranial tandem occlusions (100% vs. 48%, p = 0.033). Symptomatic intracerebral hemorrhage occurred in one patient (3.6%). Mortality rate was 0% (0/28) after 3 months. Emergent carotid artery stenting in setting of acute stroke was a safe and effective treatment modality. Successful recanalization (extracranial and intracranial) and absence of intracranial tandem occlusion are significantly associated with a good outcome for our cohort of patients whom undergone emergent carotid artery stenting.
International Nuclear Information System (INIS)
Wang Ziliang; Xu Haowen; Li Tianxiao; Zhu Liangfu; Li Zhaoshuo; Xue Jiangyu; Bai Weixing; Li Li; Guan Sheng
2011-01-01
Objective: To evaluate the incidence, potential hazards and effective countermeasure for perforator stroke (PS) resulting from stent angioplasty of symptomatic intracranial artery stenosis. Methods: Peri-operation PS complications of 258 patients receiving Gateway balloon-Wingspan stenting for severe symptomatic intracranial stenosis were analyzed. The incidence, clinical course, and prognosis of PS resulting from stenting were recorded. Special attention was given to the anatomical features, clinical manifestation and video materials of patients with PS. χ 2 test was used for statistics. Results: Two hundred and fifty-five patients received stent angioplasty successfully and 7 patients had PS (incidence rate 2.7%). The patients with basilar artery stenosis had a higher incidence of PS resulting from intracranial stenting (6.1%, 4/66) than patients with middle cerebral artery stenosis (2.5%, 3/118) (χ 2 =2.320, P= 0.025). The potential hazards for PS included preoperative perforator stroke adjacent to the stenotic segment and prominent dissection during operation. Six patients presented symptoms after awake from general anaesthesia and one had symptoms 3 hours after stenting. One deteriorated gradually and the others reached the maximum deficit almost at once. At the follow-up of 3 months, 3 patients were disabled and scored one, two, two by mRS respectively. Conclusion: The incidence of PS resulting from intracranial stenting was low and the prognosis was not disastrous. Stenosis at basilar artery and preoperative perforator stroke adjacent to the stenotic segment were potential risk factors for PS complication. Proper maneuver of angioplasty may decrease the incidence of PS and improve the prognosis. (authors)
Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.
Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele
2016-08-01
To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.
Thirty-day outcomes of direct carotid artery stenting with cerebral protection in high-risk patients
International Nuclear Information System (INIS)
Veselka, J.; Cerna, D.; Zimolova, P.; Blasko, P.; Fiedler, J.; Hajek, P.; Maly, M.; Zemanek, D.; Duchonova, R.
2007-01-01
Implantation of a carotid artery stent after predilation is a standard approach in the endovascular treatment of carotid artery stenoses. Stenting without predilation may be an alternative approach in a certain subset of patients. The present prospective, single-center registry was designed to evaluate the feasibility and safety of direct carotid artery stenting (DCAS) in high-risk patients. Symptomatic patients with stenosis >50% and asymptomatic patients with stenosis >70% were eligible for enrolment. Criteria for high-risk patients included: need or history of open heart surgery, history of myocardial infarction, multivessel coronary artery disease, left ventricular dysfunction (ejection fraction ≤40%), severe pulmonary or renal disease, significant contralateral carotid disease, previous endarterectomy, and age ≥80 years. All procedures were performed using a filter protection device. Patients underwent complete clinical examination before and after DCAS and at 30-day follow-up. A total of 83 consecutive patients (45 males, 68±9 years, 33% symptomatic) underwent 100 procedures and 103 stents were deployed successfully. The technical success rate of stenting was 100%. Predilation of carotid stenosis was necessary in 1 (1%) procedure. Carotid-artery stenoses before and after DCAS were 80±9% and 7±9%, respectively. The median fluoroscopic time for DCAS was 7 min. The overall rate of in-hospital major adverse cerebrovascular events (death, stroke, myocardial infarction) was 5% (2 minor strokes, 3 transient attacks). There was 1 (1%) minor stroke within the 30-day follow-up. DCAS is feasible and can be performed with an acceptable risk in high-risk patients. (author)
Directory of Open Access Journals (Sweden)
Gates L
2013-09-01
Full Text Available Lindsay Gates, Jeffrey Indes Vascular and Endovascular Surgery, Yale University School of Medicine, New Haven, CT, USA Abstract: Management of iliac artery disease has evolved over the years, from a surgical-only approach to a primarily endovascular-only approach as the first line treatment option. This has been continuously improved upon with the advent of new devices and applied technologies. Most recently in particular, the literature has shown good, reliable outcomes with the use of self-expandable stents in iliac artery atherosclerotic lesions. Nevertheless, no device is without its limitations, and the Absolute Pro® Vascular Self-Expanding Stent System was designed with the intent of overcoming some of the shortcomings of other available stents while maintaining acceptable postprocedural outcomes. Based on preliminary industry-acquired data, it has achieved these goals and appears to be an emergent competitor for the treatment of both focal and complex iliac artery lesions. Keywords: Absolute-Pro®, iliac stent, self-expanding stents, atherosclerotic disease
International Nuclear Information System (INIS)
Kurz, P.; Stampfl, U.; Christoph, P.; Henn, C.; Satzl, S.; Radeleff, B.; Berger, I.; Richter, G. M.
2011-01-01
Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% ± 8.43% at 12 weeks in BNS versus 39.77% ± 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 ± 1.17 versus 2.17 ± 0.85 in BNS. The results for vessel wall injury (0.6 ± 0.58 for Polyzene-F-coated stents; 0.72 ± 0.98 for BNS) and re-endothelialization, (1.16 ± 0.43 and 1.23 ± 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies (≥120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.
Detection of vessel wall calcifications in vertebral arteries using susceptibility weighted imaging
Energy Technology Data Exchange (ETDEWEB)
Adams, Lisa C.; Boeker, Sarah M.; Bender, Yvonne Y.; Fallenberg, Eva M.; Wagner, Moritz; Hamm, Bernd; Makowski, Marcus R. [Department of Radiology, Charite, Berlin (Germany); Liebig, Thomas [Department of Neuroradiology, Charite, Berlin (Germany)
2017-09-15
Calcification of the brain supplying arteries has been linked to an increased risk for cerebrovascular disease. The purpose of this study was to test the potential of susceptibility weighted MR imaging (SWMR) for the detection of vertebral artery calcifications, based on CT as a reference standard. Four hundred seventy-four patients, who had received head CT and 1.5 T MR scans with SWMR, including the distal vertebral artery, between January 2014 and December 2016, were retrospectively evaluated and 389 patients were included. Sensitivity and specificity for the detection of focal calcifications and intra- and interobserver agreement were calculated for SWMR and standard MRI, using CT as a standard of reference. The diameter of vertebral artery calcifications was used to assess correlations between imaging modalities. Furthermore, the degree of vessel stenosis was determined in 30 patients, who had received an additional angiography. On CT scans, 40 patients showed a total of 52 vertebral artery calcifications. While SWMR reached a sensitivity of 94% (95% CI 84-99%) and a specificity of 97% (95% CI 94-98%), standard MRI yielded a sensitivity of 33% (95% CI 20-46%), and a specificity of 93% (95% CI 90-96%). Linear regression analysis of size measurements confirmed a close correlation between SWMR and CT measurements (R {sup 2} = 0.74, p < 0.001). Compared to standard MRI (ICC = 0.52; CI 0.45-0.59), SWMR showed a higher interobserver agreement for calcification measurements (ICC = 0.84; CI 0.81-0.87). For detection of distal vertebral artery calcifications, SWMR demonstrates a performance comparable to CT and considerably higher than conventional MRI. (orig.)
Reperfusion hemorrhage following superior mesenteric artery stenting.
LENUS (Irish Health Repository)
Moore, Michael
2012-02-03
Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.
International Nuclear Information System (INIS)
Cao Jun; Liu Hongqiang; He Yang; Xia Ning; Zhang Honglei; Qiao Delin
2011-01-01
Objective: To investigate the clinical effect of metallic stent implantation together with intra-arterial chemotherapy in treating malignant gastric and duodenal obstruction. Methods: A total of 32 patients with malignant gastric and duodenal obstruction were enrolled in this study. The obstructed sites were located at the gastric sinus and pylorus part (n=16), at the gastroduodenal anastomotic stoma (n=6) or at the descending part of duodenum (n=10). Under DSA guidance and with the additional help of endoscopy, a guide-wire was orally placed in the gastroduodenal obstructed site, which was followed by the implantation of the self-expanding metallic stent (Ni-Ti alloy). Postoperative intra-arterial chemotherapy via the tumor-feeding arteries was carried out in 16 patients (dual interventional therapy). The clinical results were analyzed. Results: Successful stent insertion was achieved in all 32 patients (100%). After stent implantation the obstructive symptoms were markedly relieved and the food intake was improved. No serious complications occurred. The median survival time for the 16 patients who had received dual interventional therapy was 9.3 months, while the median survival time for the other 16 patients who had received simple stenting therapy was 5.7 months. Conclusion: For the treatment of inoperable malignant gastroduodenal obstruction, the implantation of metallic self-expanding stents is a technically simple, clinically safe and effective palliative measure. Combined with postoperative intra-arterial chemotherapy, the metal stent implantation can control the tumor growth and elongate the survival time. (authors)
Kamada, Takashi; Tateishi, Takahisa; Yamashita, Tamayo; Nagata, Shinji; Ohyagi, Yasumasa; Kira, Jun-Ichi
2013-01-01
We report a 58-year-old man showing spastic paraparesis due to medulla oblongata compression by tortuous vertebral arteries. He noticed weakness of both legs and gait disturbance at the age of 58 years and his symptoms progressively worsened during the following several months. General physical findings were normal. Blood pressure was normal and there were no signs of arteriosclerosis. Neurological examination on admission revealed lower-limb-dominant spasticity in all four extremities, lower-limb weakness, hyperreflexia in all extremities with positive Wartenberg's, Babinski's and Chaddock's signs, mild hypesthesia and hypopallesthesia in both lower limbs, and spastic gait. Cranial nerves were all normal. Serum was negative for antibodies against human T-cell lymphotropic virus-1 antibody. Nerve conduction and needle electromyographic studies of all four limbs revealed normal findings. Cervical, thoracic and lumbo-sacral magnetic resonance imaging (MRI) findings were all normal. Brain MRI and magnetic resonance angiography demonstrated bilateral tortuous vertebral arteries compressing the medulla oblongata. Neurovascular decompression of the right vertebral artery was performed because compression of the right side was more severe than that of the left side. Post-operative MRI revealed outward translocation of the right vertebral artery and relieved compression of the medulla oblongata on the right side. The patient's symptoms and neurological findings improved gradually after the operation. Bilateral pyramidal tract signs without cranial nerve dysfunction due to compression of the medulla oblongata by tortuous vertebral arteries are extremely rare and clinically indistinguishable from hereditary spastic paraplegia (HSP). Although we did not perform a genetic test for HSP, we consider that the spastic paraparesis and mild lower-limb hypesthesia were caused by compression of the medulla oblongata by bilateral tortuous vertebral arteries based on the post
Energy Technology Data Exchange (ETDEWEB)
Zocholl, G; Zapf, S; Schild, H; Thelen, M [Mainz Univ. (Germany, F.R.). Inst. fuer Klinische Strahlenkunde
1990-12-01
Angiographic studies of the arteries adjoining the knee in 25 patients show extensive kinking and stenoses of the popliteal artery and less frequently of the distal femoral artery during flexion of the knee joint. This is due to the loss of elasticity with increasing age forcing the vessel into a tortuous course during shortening of the pathway of the popliteal artery with knee flexion. Independent of the principle of the different stents available they probably will not increase the contractility of the stented vessel in the longitudinal axis. It is to expect that after implantation of stents into the original artery kinking will occur predominantly in the original segments of the vessel and at the transitions to the stented segments leading to intimal damage by shear forces thus propagating local progress of atherosclerosis. (orig.).
LENUS (Irish Health Repository)
Ederle, Jörg
2010-03-20
Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy.
Distribution of the blood flow supplied by the vertebral artery in humans as assessed by emission CT
International Nuclear Information System (INIS)
Taki, W.; Handa, H.; Higa, T.; Tanada, S.; Fukuyama, H.; Fujita, T.; Yonekawa, Y.; Kameyama, M.; Torizuka, K.
1984-01-01
Though unilateral blood distribution of the vertebral artery has not been studied in humans, it is significant when considering the ischemic events especially embolic occlusion in vertebrobasilar system. To clarify the blood distribution, Krypton-81m was continuously infused into the vertebral arteries of 10 patients. Radioactivity was recorded by a rotating gamma camera. The perfusion images, reconstructed by computer in the transaxial plane, were classified according to whether the distribution was equal, or predominantly unilateral. Overlapping of blood supply from each vertebral artery was studied. In addition, the perfusion from one of the vertebral arteries revealed four distribution patterns with respect to laterality. A) ipsilateral; B) contralateral; C) bilateral; D) mosaic. Images obtained following perfusion of the vertebral artery show less uniformity compared to that of the internal carotid artery, suggesting a complicated vascular supply of the vertebral basilar territory. This complex distribution can be classified by the use of continuous infusion of Krypton-81m
Directory of Open Access Journals (Sweden)
Michael Köhler
2011-01-01
Full Text Available Purpose. To test different peripheral arterial stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation and image noise in dual-source multidetector row CT (DSCT in vitro. Methods and Materials. 22 stents (nitinol, steel, cobalt-alloy, tantalum, platinum alloy were examined in a vessel phantom. All stents were imaged in axial orientation with standard parameters. Image reconstructions were obtained with four different convolution kernels. To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density and noise were measured. Results. The mean percentage of the visible stent lumen diameter from the nominal stent diameter was 74.5% ± 5.7 for the medium-sharp kernel, 72.8% ± 6.4 for the medium, 70.8% ± 6.4 for the medium-smooth and 67.6% ± 6.6 for the smooth kernel. Mean values of lumen attenuation were 299.7HU ± 127 (medium-sharp, 273.9HU ± 68 (medium, 270.7HU ± 53 (medium-smooth and 265.8HU ± 43. Mean image noise was: 54.6 ± 6.3, 20.5 ± 1.7, 16.3 ± 1.7, 14.0 ± 2 respectively. Conclusion. Visible stent lumen diameter varies depending on stent type and scan parameters. Lumen diameter visibility increases with the sharpness of the reconstruction kernel. Smoother kernels provide more realistic density measurements inside the stent lumen and less image noise.
Impact of diabetes mellitus on outcome of renal artery stenting
International Nuclear Information System (INIS)
Song Li; Tong Xiaoqiang; Wang Jian; Yang Min; Lv Yongxing; Zou Yinghua
2007-01-01
Objective: To investigate the impact of diabetes mellitus on outcome of renal artery stenting. Methods: 85 consecutive cases of renal artery stenosis received renal angioplasty were retrospectively analyzed. 25 patients with related history were selected into diabetic group (DM), and 60 patients without diabetics into control group(NDM). Pre- and post- procedure serum creatinine and blood pressure between the 2 groups were collected and analyzed. Results: The average serum creatinine pre-intervention and post-intervention were(132.24 ± 33.71) μmol/L, (126.32 ± 29.65) μmol/L for DM group, and(125.02 ± 48.13) μmol/L, (118.31 ± 39.58) μmol/L for NDM group respectively with no significant statistical difference (P > 0.05). The blood pressure was controlled satisfactorily for both groups after the procedure, with statistical significance (P<0.05), but no difference between the two groups. Conclusions: The procedure with renal artery stenting is effective to maintain renal function and control hypertension, showing equal efficiency for both DM and NDM patients. (authors)
DEFF Research Database (Denmark)
Kelbaek, H.; Klovgaard, L.; Helqvist, S.
2008-01-01
data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... performed between 1 and 3 years after the index treatment (p = NS). According to revised definitions, stent thrombosis occurred in 5 patients (3.1%) in the SES group and in 7 patients (4.4%) in the BMS group (p = NS); very late stent thrombosis was observed in 4 versus 1 patient. CONCLUSIONS: A continued...
International Nuclear Information System (INIS)
Li Minghua; Luo Qiyi; Fang Chun; Xie Zhiyong; Cheng Yingsheng; Gao Bulang; Li Yu; Zhang Beilei; Xie Jian; Wang Yongli
2007-01-01
Objective: To investigate the flexibility of both the covered stents specially designed for use in intracranial vasculature and the delivering system in passing through the bone tube and the physiological curves of the cranial internal carotid artery (CICA) to reach the targeted area, the performance (adherence) of the covered stents in occluding vascular wall diseases and the impact on the vascular branches of the covered segment. Methods: The covered stents specially designed for use in intracranial vasculature were used to treat 13 patients with CICA diseases using endovascular techniques. There were 4 huge pseudoaneurysms, 4 giant aneurysms, 3 small wide-necked aneurysms, 1 giant pseudoaneurysm with concurrent internal carotid cavernous fistula (CCF), and 1 CCF. Prior to the detachment of the covered stents, balloon occlusion test (BOT) of the internal carotid artery on the diseased side and whole-brain digital subtraction angiography (DSA) were performed in all the patients. Three to 16 months following procedure, DSA and clinical follow-ups were performed. Results: Thirteen patients all tolerated the BOT well with the DSA demonstrating well-opened anterior and posterior communicating arteries. The covered stents and the delivering systems all successfully passed CICA to reach the targeted diseased area, with the diseased segments of the internal carotid artery including C3-C4 in 4 cases, C4-C5 in 4 and C6-C7 in 5. Immediately following the detachment of the covered stents, DSA demonstrated that 7 aneurysms were completely occluded, 4 aneurysms had slight endoleak, and 1 CCF had markedly-decreased blood flow through the fistula. In the patient with concurrent pseudoaneurysm and CCF, the pseudoaneurysm disappeared and the blood flow through the fistula was markedly-reduced immediately following the stenting procedure. Apart from one patient with aneurysmal subarachnoid hemorrhage who died due to extensive vascular spasm on the 9th day following the stenting
Clinical benefits of drug-eluting stent implantation in septuagenarians with coronary artery disease
International Nuclear Information System (INIS)
Fang Yuehua; Shen Weifeng; Zhang Ruiyan; Zhang Jiansheng; Hu Jian; Zhang Xian; Zheng Aifang
2005-01-01
Objective: This study evaluated the safety and long-term outcomes of drug-eluting stents in septuagenarians with coronary artery disease. Methods: Two hundred and thirty-nine consecutive patients with coronary artery disease underwent drug-eluting stenting, including 88 patients aged ≥70 years (group A) and 151 aged <70 years (group B). Baseline clinical characteristics, procedural success rate, occurrence of cardiac events during follow-up were recorded and compared between the two groups. Results: Procedural success rate and complications were similar for the two groups. During follow-up, group A had higher recurrence rate of chest pain than group B (23.9% vs. 7.3%, P<0.001), and occurrence of cardiac events was higher in group A than in group B (5.7% vs. 2.7%, P<0.296). There was no significant difference in the frequency of restenosis between the two groups. Conclusions: Drug-eluting stent implantation for septuagenarians with coronary artery disease is safe but may have more recurrence of angina than younger ones during long-term follow-up. (authors)
Vertebral basilar artery dissections
International Nuclear Information System (INIS)
Zimmerman, R.A.; Bilaniuk, L.T.; Hackney, D.B.; Grossman, R.I.; Goldberg, H.I.; Atlas, S.W.
1988-01-01
Eleven patients (ten male, one female; range, 2-56 years) presented with posterior circulation ischemic symptoms and were evaluated with computed tomography (CT) (eta=11), arteriography (eta=11), and magnetic resonance (MR) imaging (eta=6). Angiography showed dissection of a vertebral artery (eta=8), a basilar artery (eta=1), or a combination of both (eta=2). On CT and/or MR images, infarctions were demonstrated in ten of 11 cases. Most frequently involved were the thalmus (eta=7), cerebellum (eta=6), occipital lobes (eta=4), and pons (eta=3). The site of infarction did not correlate with the side or site of angiographic abnormality. In six cases evaluated by all modalities, MR imaging showed more extensive and widespread infarction than did CT and also showed whether or not the infarcts were hemorrhagic. MR imaging was able to demonstrate the presence of intramural dissecting hematoma prior to angiography and to indicate whether or not flow was reconstituted on follow-up examination
Spontaneous coronary artery dissection: complete angiographic resolution without stenting
Directory of Open Access Journals (Sweden)
Alexandre Abizaid
2007-09-01
Full Text Available A case of spontaneous coronary artery dissection in a 49-year-oldwoman is presented. She did not present the classical cardiovascular riskfactors. Etiology and treatment are discussed. She underwent primarypercutaneous coronary intervention of the left anterior descendingartery with no stenting and had complete angiographic resolution.
Anomalous Origin of the Left Vertebral Artery from the Aortic Arch.
Einstein, Evan H; Song, Linda H; Villela, Natalia L A; Fasani-Feldberg, Gregory B; Jacobs, Jonathan L; Kim, Dolly O; Nathawat, Akshay; Patel, Devika; Bender, Roger B; Peters, Daniel F
2016-04-01
Anatomic anomalies of the aortic arch have implications for clinical practice if their significance is understood. Our case study involves a cadaveric finding of the left vertebral artery originating directly from the aortic arch. Although this anatomical variation has been documented, the prevalence of this anomaly may be generally underestimated. After noting this anomaly, we analyzed 27 cases and found that four female cadavers had the left vertebral artery originating from the aortic arch rather than the left subclavian artery. With a prevalence rate of 14.8%, it would seem that this anomaly is more significant than previously thought, which could have implications for surgical practice.
International Nuclear Information System (INIS)
Kim, Eui Jong; Koh, Jun Seok; Choi, Woo Suk
2006-01-01
We report here on a rare case of carotid artery angioplasty and stenting in a patient with spontaneous recanalization after complete occlusion of the proximal internal carotid artery (ICA). The patient initially showed severe stenosis at the left proximal ICA on MR angiography (MRA). Digital subtraction angiography (DSA) performed three days after MRA showed complete occlusion of the proximal ICA. The follow-up DSA after four weeks showed recanalization of the ICA, and then carotid artery stenting was successfully performed. There has been no neurologic complication during more than one year follow-up. cute internal carotid artery (ICA) occlusions may result in profound disability and death (1). An occluded ICA can spontaneously recanalize, but this doesn't happen frequently, and the natural course of a proximal ICA occlusion and its possibility of recanalization, including the exact time of recanalization after occlusion, are not well known (2, 3). A few studies have reported the incidence of spontaneous recanalization of the proximal internal carotid artery, which has mostly occurred in patients with ICA dissections (4 6). A few limited studies have reported a considerable incidence of spontaneous recanalization in patients with underlying atherosclerotic lesion or atherothombotic diseases (2). The possibility of repeated occlusion and repeated cerebral ischemic infarction may exist for the patients exhibiting spontaneous recanalization of the ICA and underlying atherosclerosis. We report here on a case of carotid artery stenting (CAS) in a patient who exhibited underlying atherosclerosis with spontaneous recanalization after complete occlusion of the proximal ICA
Post-traumatic cerebellar infarction due to vertebral artery foramina fracture: case report
Directory of Open Access Journals (Sweden)
Moscote-Salazar Luis Rafael
2016-03-01
Full Text Available Posttraumatic cerebral infarction is an uncommon cause of morbidity and mortality and many studies have highlighted that trauma needs to considered as causative factor for cerebellar infarction. We present a case of cerebellar infarction in a 35 year old young patient secondary to vertebral fracture involving the vertebral foramen and vertebral artery injury. CT scan cervical spine showed C2-3 fracture on left side with fracture extending into the left vertebral foramen. A CT scan angiogram could not be performed because of poor neurological status. Possibly the infarction was due to left vertebral artery injury. Without surgical intervention prognosis of these patients remain poor. Prognosis of patients with traumatic cerebellar infarction depends on the neurological status of the patient, intrinsic parenchymal damage and more importantly extrinsic compression of the brainstem by the edematous cerebellar hemispheres.
Renal Artery Stenosis in Patients with Resistant Hypertension: Stent It or Not?
Van der Niepen, Patricia; Rossignol, Patrick; Lengelé, Jean-Philippe; Berra, Elena; Sarafidis, Pantelis; Persu, Alexandre
2017-01-01
After three large neutral trials in which renal artery revascularization failed to reduce cardiovascular and renal morbidity and mortality, renal artery stenting became a therapeutic taboo. However, this is probably unjustified as these trials have important limitations and excluded patients most likely to benefit from revascularization. In particular, patients with severe hypertension were often excluded and resistant hypertension was either poorly described or not conform to the current definition. Effective pharmacological combination treatment can control blood pressure in most patients with renovascular hypertension. However, it may also induce further renal hypoperfusion and thus accelerate progressive loss of renal tissue. Furthermore, case reports of patients with resistant hypertension showing substantial blood pressure improvement after successful revascularization are published over again. To identify those patients who would definitely respond to renal artery stenting, properly designed randomized clinical trials are definitely needed.
Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note
Energy Technology Data Exchange (ETDEWEB)
Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito [Kainan Hospital Aichi Prefectural Welfare Federation of Agricultural Cooperatives, Department of Neurosurgery, Aichi (Japan); Miyachi, Shigeru; Hattori, Kenichi [Nagoya University Graduate School of Medicine, Department of Neurosurgery, Nagoya (Japan)
2006-11-15
Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)
Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note
International Nuclear Information System (INIS)
Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito; Miyachi, Shigeru; Hattori, Kenichi
2006-01-01
Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)
Pulmonary arterial stent implantation in an adult with Williams syndrome
Reesink, Herre J.; Henneman, Onno D. F.; van Delden, Otto M.; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul
2007-01-01
We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent
Energy Technology Data Exchange (ETDEWEB)
Ruffino, Maria Antonella, E-mail: mruffino@cittadellasalute.to.it [Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Vascular Radiology Unit, Department of Diagnostic Imaging and Radiotherapy (Italy); Faletti, Riccardo [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Radiology Unit, Department of Surgical Sciences (Italy); Bergamasco, Laura [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Department of Surgical Sciences (Italy); Fonio, Paolo [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Radiology Unit, Department of Surgical Sciences (Italy); Righi, Dorico [Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Vascular Radiology Unit, Department of Diagnostic Imaging and Radiotherapy (Italy)
2016-11-15
AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm{sup 3} (interquartile range 0.065–0.146 cm{sup 3}). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.
International Nuclear Information System (INIS)
Ruffino, Maria Antonella; Faletti, Riccardo; Bergamasco, Laura; Fonio, Paolo; Righi, Dorico
2016-01-01
AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm"3 (interquartile range 0.065–0.146 cm"3). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.
Energy Technology Data Exchange (ETDEWEB)
Hauth, E.A.; Forsting, M. [Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitaetsklinik Essen (Germany); Jansen, C.; Drescher, R.; Mathias, K. [Radiologische Klinik, Klinikum Dortmund (Germany); Schwarz, M. [Neurologische Klinik, Klinikum Dortmund (Germany); Christmann, A. [Fachbereich Statistik, Univ. Dortmund (Germany); Jaeger, H. [Radiologische Klinik, Klinikum Dortmund (Germany); Marien-Hospital Wesel, Praxis fuer Radiologie, Neuroradiologie and Nuklearmedizin (Germany)
2006-08-15
Purpose: the purpose of this prospective study was to determine the restenosis grade, the intima hyperplasia and the stent expansion via angiographic follow-up six months after carotid artery stenting. Materials and methods: in 100 patients, angiographic follow-up was performed 5.9 months (range: 2.9 - 11.4 months) after carotid artery stenting. The restenosis grade, the intima hyperplasia and the stent expansion were measured by selective angiography of the treated carotid artery. Results: the mean restenosis grade was 16% (range: 0 - 78%). In 6 of 100 patients (6%), a restenosis grade of > 50% was measured. In 4 patients the restenosis grade was 50 - 70%. In 2 patients the restenosis grade was > 70%. In 91 of 100 patients (91%), the restenosis was localized in the former area of stenosis of the carotid artery, and in 9 of 100 patients (9%), the restenosis was localized in the cranial stent end. The mean grade of intima hyperplasia was 31% (range: 2 - 70%). The mean increase in stent expansion at the time of follow-up was 10% (range: 0 - 59%). No correlation was able to be determined between the grade of stenosis and the grade of restenosis (rho = 0,017, range: -0.180 - 0.213), between the grade of residual stenosis and the grade of restenosis (rho = 0,257, range: 0.064 - 0.431) and between intima hyperplasia and the grade of restenosis (rho = 0,476, range: 0.309 - 0.615). Conclusions: carotid artery stenting is associated with a low incidence of high-grade restenosis 6 months after an intervention. The intima hyperplasia, which can be observed in each Wallstent, is partly compensated by the expansion of the self-expandable stent. Without a correlation between the grade of residual stenosis and the grade of restenosis, low-grade residual stenosis can be accepted. Therefore, we recommend undersized postdilation of the Wallstent. (orig.)
Cui, Xiaoming; Li, Tao; Li, Xin; Zhou, Weihua
2015-05-01
The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0±8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Ederle, J.; Dobson, J.; Featherstone, R.L.; Bonati, L.H.; Worp, H.B. van der; Borst, G.J. de; Lo, T.H.; Gaines, P.; Dorman, P.J.; Macdonald, S.; Lyrer, P.A.; Hendriks, J.M.; McCollum, C.; Nederkoorn, P.J.; Brown, M.M.; Blankensteijn, J.D.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,
2010-01-01
BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International
Ederle, Jörg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molyneux, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Chan, A.; Chu, P.; Clark, D.; Dewey, H.; Donnan, G.; Fell, G.; Hoare, M.; Molan, M.; Roberts, A.; Roberts, N.; Beiles, B.; Bladin, C.; Clifford, C.; Grigg, M.; New, G.; Bell, R.; Bower, S.; Chong, W.; Holt, M.; Saunder, A.; Than, P. G.; Gett, S.; Leggett, D.; McGahan, T.; Quinn, J.; Ray, M.; Wong, A.; Woodruff, P.; Foreman, R.; Schultz, D.; Scroop, R.; Stanley, B.; Allard, B.; Atkinson, N.; Cambell, W.; Davies, S.; Field, P.; Milne, P.; Mitchell, P.; Tress, B.; Yan, B.; Beasley, A.; Dunbabin, D.; Stary, D.; Walker, S.; Cras, P.; d'Archambeau, O.; Hendriks, J. M. H.; van Schil, P.; St Blasius, A. Z.; Bosiers, M.; Deloose, K.; van Buggenhout, E.; de Letter, J.; Devos, V.; Ghekiere, J.; Vanhooren, G.; Astarci, P.; Hammer, F.; Lacroix, V.; Peeters, A.; Verbist, J.; Blair, J.-F.; Caron, J. L.; Daneault, N.; Giroux, M.-F.; Guilbert, F.; Lanthier, S.; Lebrun, L.-H.; Oliva, V.; Raymond, J.; Roy, D.; Soulez, G.; Weill, A.; Hill, M.; Hu, W.; Hudion, M.; Morrish, W.; Sutherland, G.; Wong, J.; Albäck, A.; Harno, H.; Ijäs, P.; Kaste, M.; Lepäntalo, M.; Mustanoja, S.; Paananen, T.; Porras, M.; Putaala, J.; Railo, M.; Sairanen, T.; Soinne, L.; Vehmas, A.; Vikatmaa, P.; Goertler, M.; Halloul, Z.; Skalej, M.; Brennan, P.; Kelly, C.; Leahy, A.; Moroney, J.; Thornton, J.; Koelemay, M. J. W.; Reekers, J. A. A.; Roos, Y. B. W. E. M.; Hendriks, J. M.; Koudstaal, P. J.; Pattynama, P. M. T.; van der Lugt, A.; van Dijk, L. C.; van Sambeek, M. R. H. M.; van Urk, H.; Verhagen, H. J. M.; Bruijninckx, C. M. A.; de Bruijn, S. F.; Keunen, R.; Knippenberg, B.; Mosch, A.; Treurniet, F.; van Dijk, L.; van Overhagen, H.; Wever, J.; de Beer, F. C.; van den Berg, J. S. P.; van Hasselt, B. A. A. M.; Zeilstra, D. J.; Boiten, J.; van Otterloo, J. C. A. de Mol; de Vries, A. C.; Lycklama a Nijeholt, G. J.; van der Kallen, B. F. W.; Blankensteijn, J. D.; de Leeuw, F. E.; Kool, L. J. Schultze; van der Vliet, J. A.; de Borst, G. J.; de Kort, G. A. P.; Kapelle, L. J.; Lo, T. H.; Mali, W. P. Th M.; Moll, F.; van der Worp, H. B.; Verhagen, H.; Barber, P. A.; Bourchier, R.; Hill, A.; Holden, A.; Stewart, J.; Bakke, S. J.; Krohg-Sørensen, K.; Skjelland, M.; Tennøe, B.; Bialek, P.; Biejat, Z.; Czepiel, W.; Czlonkowska, A.; Dowzenko, A.; Jedrzejewska, J.; Kobayashi, A.; Lelek, M.; Polanski, J.; Kirbis, J.; Milosevic, Z.; Zvan, B.; Blasco, J.; Chamorro, A.; Macho, J.; Obach, V.; Riambau, V.; San Roman, L.; Branera, J.; Canovas, D.; Estela, Jordi; Gaibar, A. Gimenez; Perendreu, J.; Björses, K.; Gottsater, A.; Ivancev, K.; Maetzsch, T.; Sonesson, B.; Berg, B.; Delle, M.; Formgren, J.; Gillgren, P.; Kall, T.-B.; Konrad, P.; Nyman, N.; Takolander, R.; Andersson, T.; Malmstedt, J.; Soderman, M.; Wahlgren, C.; Wahlgren, N.; Binaghi, S.; Hirt, L.; Michel, P.; Ruchat, P.; Engelter, S. T.; Fluri, F.; Guerke, L.; Jacob, A. L.; Kirsch, E.; Lyrer, P. A.; Radue, E.-W.; Stierli, P.; Wasner, M.; Wetzel, S.; Bonvin, C.; Kalangos, A.; Lovblad, K.; Murith, M.; Ruefenacht, D.; Sztajzel, R.; Higgins, N.; Kirkpatrick, P. J.; Martin, P.; Varty, K.; Adam, D.; Bell, J.; Crowe, P.; Gannon, M.; Henderson, M. J.; Sandler, D.; Shinton, R. A.; Scriven, J. M.; Wilmink, T.; D'Souza, S.; Egun, A.; Guta, R.; Punekar, S.; Seriki, D. M.; Thomson, G.; Brennan, J. A.; Enevoldson, T. P.; Gilling-Smith, G.; Gould, D. A.; Harris, P. L.; McWilliams, R. G.; Nasser, H.-C.; White, R.; Prakash, K. G.; Serracino-Inglott, F.; Subramanian, G.; Symth, J. V.; Walker, M. G.; Clarke, M.; Davis, M.; Dixit, S. A.; Dorman, P.; Dyker, A.; Ford, G.; Golkar, A.; Jackson, R.; Jayakrishnan, V.; Lambert, D.; Lees, T.; Louw, S.; Macdonald, S.; Mendelow, A. D.; Rodgers, H.; Rose, J.; Stansby, G.; Wyatt, M.; Baker, T.; Baldwin, N.; Jones, L.; Mitchell, D.; Munro, E.; Thornton, M.; Baker, D.; Davis, N.; Hamilton, G.; McCabe, D.; Platts, A.; Tibballs, J.; Cleveland, T.; Dodd, D.; Lonsdale, R.; Nair, R.; Nassef, A.; Nawaz, S.; Venables, G.; Belli, A.; Cloud, G.; Halliday, A.; Markus, H.; McFarland, R.; Morgan, R.; Pereira, A.; Thompson, A.; Chataway, J.; Cheshire, N.; Gibbs, R.; Hammady, M.; Jenkins, M.; Malik, I.; Wolfe, J.; Adiseshiah, M.; Bishop, C.; Brew, S.; Brookes, J.; Jäger, R.; Kitchen, N.; Ashleigh, R.; Butterfield, S.; Gamble, G. E.; McCollum, C.; Nasim, A.; O'Neill, P.; Edwards, R. D.; Lees, K. R.; MacKay, A. J.; Moss, J.
2010-01-01
BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International
Ederle, Joerg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Bradbury, A.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molynewc, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Hendriks, J. M. H.; Hendriks, J. M.
2010-01-01
Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid
Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K
2013-02-01
To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.
International Nuclear Information System (INIS)
Wang Zhongmin; Chen Kemin; Gong Ju; Zheng Yunfeng; Wang Tianxiang
2009-01-01
Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival time between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4
Energy Technology Data Exchange (ETDEWEB)
Cui, Xiaoming, E-mail: mmayzy2008@126.com; Li, Tao, E-mail: litaofeivip@163.com; Li, Xin, E-mail: lx0803@sina.com.cn; Zhou, Weihua, E-mail: wangxue0606@gmail.com
2015-05-15
Highlights: • High-resolution scan mode is appropriate for imaging coronary stent. • HD-detail reconstruction algorithm is stent-dedicated kernel. • The intrastent lumen visibility also depends on stent diameter and material. - Abstract: Objective: The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Materials and methods: Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. Results: The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0 ± 8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Conclusions: Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement.
FiberNet--a new embolic protection device for carotid artery stenting.
Bauer, C; Franke, J; Bertog, S C; Woerner, V; Ghasemzadeh-Asl, S; Sievert, H
2014-05-01
Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device. The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting. All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure. Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke. The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. Copyright © 2013 Wiley Periodicals, Inc.
Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula
Energy Technology Data Exchange (ETDEWEB)
Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)
2017-06-15
PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.
A novel application of the culotte stent technique to bail out a jailed common iliac artery
Directory of Open Access Journals (Sweden)
Hideto Sangen, MD
2017-12-01
Full Text Available Implanting a self-expandable stent at the ostium of the common iliac artery (CIA may lead to coverage of the orifice of the contralateral CIA. Here, we describe a novel application of the culotte stent technique using a balloon-expandable stent to bail out an ostial stenotic legion of a jailed CIA due to prior self-expandable stent placement. The bilateral CIAs were revascularized by culotte stenting, and patency of the stents was confirmed 3 years after the procedure. The culotte stent technique was successfully applied to an ostial stenotic lesion of a jailed CIA.
Endovascular repair of renal artery aneurysm with the multilayer stent – a short report
Directory of Open Access Journals (Sweden)
Vojko Flis
2012-10-01
in the main left renal artery involving all three major branches of the renal artery. Via a percutaneous femoral approach a multilayer stent was deployed without complications. Blood flow inside the sac was immediately and significantly reduced. All the renal branches remained patent. Conclusion: New multilayer fluid modulating stent concept appears to be a very useful and attractive alternative to surgery or other endovascular techniques for those RAA involving or very close to major branch vessels, especially in patients with very high risk of loosing the only viable kidney, as in our case.
Ischemic stroke: carotid and vertebral artery disease
Energy Technology Data Exchange (ETDEWEB)
Vilela, P.; Goulao, A. [Hospital Garcia de Orta, Servico de Neurorradiologia, Almada (Portugal)
2005-03-01
Ischemic strokes may have distinct aetiologies, including several different intrinsic arterial pathological disorders. The diagnosis and understanding of these arterial diseases is critical for the correct management of stroke as different treatment approaches are undertaken according to the aetiology. Atherosclerosis is by far the most common arterial disease among adults, and other pathological processes include arterial dissection, small vessel disease, inflammatory and non-inflammatory vasculopathy and vasomotor disorders. In children, there are several vasculopathies responsible for vaso-occlusive disease such as sickle-cell anemia, acute regressive angiopathy and Moya-Moya disease, neurofibromatosis, dissections, vasculitis associated with intracranial and systemic infections. An overview of the major carotid and vertebral pathological diseases responsible for ischemic stroke in adults and children, highlighting the accuracy of the different imaging modalities for its diagnosis and the imaging appearance of these diseases, is given. (orig.)
Ischemic stroke: carotid and vertebral artery disease
International Nuclear Information System (INIS)
Vilela, P.; Goulao, A.
2005-01-01
Ischemic strokes may have distinct aetiologies, including several different intrinsic arterial pathological disorders. The diagnosis and understanding of these arterial diseases is critical for the correct management of stroke as different treatment approaches are undertaken according to the aetiology. Atherosclerosis is by far the most common arterial disease among adults, and other pathological processes include arterial dissection, small vessel disease, inflammatory and non-inflammatory vasculopathy and vasomotor disorders. In children, there are several vasculopathies responsible for vaso-occlusive disease such as sickle-cell anemia, acute regressive angiopathy and Moya-Moya disease, neurofibromatosis, dissections, vasculitis associated with intracranial and systemic infections. An overview of the major carotid and vertebral pathological diseases responsible for ischemic stroke in adults and children, highlighting the accuracy of the different imaging modalities for its diagnosis and the imaging appearance of these diseases, is given. (orig.)
Endovascular treatment of penetrating arterial trauma with stent grafts.
Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos
2018-02-01
The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.
Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study
Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe
2016-05-01
In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.
Directory of Open Access Journals (Sweden)
Umberto Marcello Bracale
2014-01-01
Full Text Available The purpose of this paper is to report a salvage maneuver for accidental coverage of both renal arteries during endovascular aneurysm repair (EVAR of an infrarenal abdominal aortic aneurysm (AAA. A 72-year-old female with a 6 cm infrarenal abdominal aortic aneurysm was treated by endovascular means with a standard bifurcated graft. Upon completing an angiogram, both renal arteries were found to be accidentally occluded. Through a left percutaneous brachial approach, the right renal artery was catheterized and a chimney stent was deployed; however this was not possible for the left renal artery. A retroperitoneal surgical approach was therefore carried out with a retrograde chimney stent implanted to restore blood flow. After three months, both renal arteries were patent and renal function was not different from the baseline. Both endovascular with percutaneous access via the brachial artery and open retroperitoneal approaches with retrograde catheterization are feasible rescue techniques to recanalize the accidentally occluded renal arteries during EVAR.
International Nuclear Information System (INIS)
Chalmers, Nicholas; Walker, Paul T.; Belli, Anna-Maria; Thorpe, Anthony P.; Sidhu, Paul S.; Robinson, Graham; Ransbeeck, Mariella van; Fearn, Steven A.
2013-01-01
To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5–22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months’ follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.
Directory of Open Access Journals (Sweden)
Chuan-Chuan Wang
Full Text Available The Low-profile Visualized Intraluminal Support (LVIS device is a new generation of self-expanding braided stent recently introduced in China for stent assisted coiling of intracranial aneurysms. The aim of our study is to evaluate the feasibility, safety, and efficacy of the LVIS device in reconstructive treatment of vertebral artery dissecting aneurysms (VADAs.We retrospectively reviewed the neurointerventional database of our institution from June 2014 to May 2016. Patients who underwent endovascular treatment of VADAs with LVIS stents were included in this study. Clinical presentation, aneurysmal characteristics, technical feasibility, procedural complications, and angiographic and clinical follow-up results were evaluated.38 patients with VADAs who underwent treatment with LVIS stent were identified, including 3 ruptured VADAs. All VADAs were successfully treated with reconstructive techniques including the stent-assisted coiling (n = 34 and stenting only (n = 4. Post-procedural complications developed in 3 patients (7.9% including two small brainstem infarctions and one delayed thromboembolic event. Complications resulted in one case of minor permanent morbidity (2.6%. There was no procedure-related mortality. The follow-up angiogram was available in 30 patients at an average of 8.3 months (range, 2 to 30 months, which revealed complete occlusion in 23 patients (76.7%, residual neck in five patients (16.7%, and residual sac in two patients (6.7%. The follow-up of 25 aneurysms with incomplete immediate occlusion revealed 22 aneurysms (88% with improvement in the Raymond class. One aneurysm (3.3% showed recanalization and required retreatment. Clinical followed-up at 5-28 months (mean 14.1 months was achieved in 36 patients because two patients died of pancreatic cancer and basal ganglia hemorrhage, respectively. No new neurologic deterioration or aneurysm (rebleeding was observed.Our preliminary experience with reconstruction of VADAs with
Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries
Energy Technology Data Exchange (ETDEWEB)
Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)
2015-04-15
Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with
International Nuclear Information System (INIS)
Tan, W.S.; Wilbur, A.C.; Jafar, J.; Abejo, R.; Kumasaki, D.; Crowell, R.; Spigos, D.G.
1987-01-01
Two men, aged 50 and 40 years, were treated for intracranial vertebral artery dolichoectasia using angiographic transcatheter balloon occlusion of the ipsilateral vertebral artery. Radiologic balloon occlusion was selected as an alternative to surgical ligation of the vertebral artery. Both patients had clinical signs and symptoms related to compression of both the brain stem and multiple cranial nerves. Both patients underwent occlusion of the ipsilateral vertebral artery with detachable balloons positioned at the C-1 level, below the lesions but above potential collateral pathways from the thyrocervical trunk. There were no procedural complications, and each patient has shown clinical improvement during follow-up periods of 12 months and 6 months, respectively
Hong, Jeong-Ho; Sohn, Sung-Il; Kwak, Jaehyuk; Yoo, Joonsang; Chang, Hyuk Won; Kwon, O-Ki; Jung, Cheolkyu; Chung, Inyoung; Bae, Hee-Joon; Lee, Ji Sung; Han, Moon-Ku
2017-07-01
We investigated whether statin pretreatment can dose dependently reduce periprocedural complications in patients undergoing carotid artery stenting because of symptomatic carotid artery stenosis. We enrolled a consecutive series of 397 symptomatic carotid artery stenosis (≥50% stenosis on conventional angiography) treated with carotid artery stenting at 2 tertiary university hospitals over a decade. Definition of periprocedural complications included any stroke, myocardial infarction, and death within 1 month after or during the procedure. Statin pretreatment was divided into 3 categories according to the atorvastatin equivalent dose: none (n=158; 39.8%), standard dose (statin use were 12.0%, 4.5%, and 1.2%. After adjustment, a change in the atorvastatin dose category was associated with reduction in the odds of periprocedural complications for each change in dose category (standard-dose statin: odds ratio, 0.24; 95% confidence interval, 0.07-0.81; high-dose statin: odds ratio, 0.11; 95% confidence interval, 0.01-0.96; P for trend=0.01). Administration of antiplatelet drugs was also an independent factor in periprocedural complications (OR, 0.18; 95% CI, 0.05-0.69). This study shows that statin pretreatment may reduce the incidence of periprocedural complications dose dependently in patients with symptomatic carotid artery stenting. © 2017 American Heart Association, Inc.
International Nuclear Information System (INIS)
Choi, Won Jin; Baik, Seung Kug; Yeom, Jeong A; Kim, Young Soo; Lee, Sang Weon
2014-01-01
To compare the mid-term follow-up angiographic findings in distal internal carotid artery (ICA) aneurysms treated by stent-assisted coil embolization using the Enterprise or Neuroform stent. We included 68 patients with 70 aneurysms: 31 cases with Enterprise and 39 cases with Neuroform. Inclusion criteria were 1) location of the stent within the distal ICA, including the carotid siphon; 2) follow-up angiogram after > 6 months, and 3) single use of the stent for 1 parent artery. The patients' mean age was 54.9 years (16 male and 52 female). Mean follow-up duration was 9.1 months. At follow-up, there were intraluminal filling defects of the parent artery in 19.4% of the Enterprise group and no filling defect in the Neuroform group. There was no significant in-stent stenosis in either group. Straightening of the parent artery was seen in 35.5% of the Enterprise group and 20.5% of the Neuroform group. Two Enterprise cases showed delayed migration. The Enterprise showed statistically significant intraluminal filling defects of the parent artery compared with the Neuroform. The rates of significant in-stent stenosis and straightening of the parent artery were not significantly different between the Enterprise and the Neuroform groups.
Vascular Pathology in the Extracranial Vertebral Arteries in Patients with Acute Ischemic Stroke
DEFF Research Database (Denmark)
Bentsen, L; Nygård, A; Ovesen, C
2014-01-01
INTRODUCTION: Vascular pathology in the extracranial vertebral arteries remains among the possible causes in cryptogenic stroke. However, the diagnosis is challenged by the great variety in the anatomy of the vertebral arteries, clinical symptoms and difficulties in the radiological assessments....... The aim of this study was to assess the prevalence of CT angiography (CTA)-detected pathological findings in the extracranial vertebral arteries in an acute stroke population and secondly to determine the frequency of posterior pathology as probable cause in patients with otherwise cryptogenic stroke....... METHOD: The analysis was based on 657 consecutive patients with symptoms of acute stroke and a final diagnosis of ischemic stroke or transient ischemic attack. On admission, a noncontrast CT cerebrum and CTA were performed. A senior consultant neuroradiologist, blinded to clinical data, reviewed all CTA...
DEFF Research Database (Denmark)
Raungaard, Bent; Christiansen, Evald H; Bøtker, Hans Erik
2017-01-01
artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion......OBJECTIVES: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients. BACKGROUND: Biodegradable-polymer biolimus-eluting stents are superior to first......-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking. METHODS: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary...
Choi, Woong Gil; Rha, Seung Woon; Choi, Cheol Ung; Kim, Eung Ju; Oh, Dong Joo; Cho, Yoon Hyung; Park, Sang Ho; Lee, Seung Jin; Hur, Ae Yong; Ko, Young Guk; Park, Sang Min; Kim, Ki Chang; Kim, Joo Han; Kim, Min Woong; Kim, Sang Min; Bae, Jang Ho; Bong, Jung Min; Kang, Won Yu; Seo, Jae Bin; Jung, Woo Yong; Cho, Jang Hyun; Kim, Do Hoi; Ahn, Ji Hoon; Kim, Soo Hyun; Jang, Ji Yong
2016-06-25
The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.
Conformally integrated stent cell resonators for wireless monitoring of peripheral artery disease
Viswanath, Anupam
2013-01-01
This paper presents the design and in vitro evaluation of magnetoelastic sensors intended for wireless monitoring of tissue accumulation in peripheral artery stents. The sensors, shaped like stent cells, are fabricated from 28-μm thick foils of magnetoelastic Ni-Fe alloy and are conformally integrated with the stent. The typical sensitivity to viscosity is 427 ppm/cP over a 1.1-8.6 cP range. The sensitivity to mass loading is typically 63,000-65000 ppm/mg with resonant frequency showing an 8.1% reduction for an applied mass that is 15% of the unloaded mass of the sensor. © 2013 IEEE.
International Nuclear Information System (INIS)
Wolf, Florian; Feuchtner, Gudrun M.; Homolka, Peter; Langenberger, Herbert; Stadler, Alfred; Bader, Till R.; Weber, Michael; Lammer, Johannes; Loewe, Christian
2008-01-01
Purpose: To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents. Methods and materials: Twelve different coronary artery stents were placed in the drillings of a combined heart and chest phantom, which was scanned with a 16- and 64-slice CT scanner. Coronal reformations were evaluated for artificial lumen narrowing, intraluminal attenuation values, and false widening of the outer stent diameter as an indicator of artifacts outside the stent. Results: Mean artificial lumen narrowing was not significantly different between the 16- and 64-slice CT scanner (44% versus 39%; p = 0.408). The differences between the Hounsfield Units (HU) measurements inside and outside the stents were significantly lower (p = 0.001) with 64- compared to 16-slice CT. The standard deviation of the HU measurements inside the stents was significantly (p = 0.002) lower with 64- than with 16-slice CT. Artifacts outside the stents were not significantly different between the scanners (p = 0.866). Conclusion: Visualization of the in-stent lumen is improved with 64-slice CT when compared with 16-slice CT as quantified by significantly lesser intraluminal image noise and less artificial rise in intraluminal HU measurement, which is the most important parameter for the evaluation of stent patency in vivo
International Nuclear Information System (INIS)
Wilczek, Krzysztof; Scheerder, Ivan de; Wang Kai; Verbeken, Eric; Piessens, Jan
1996-01-01
Purpose: Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). Methods: Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deployment was studied angiographically and with intravascular ultrasound immediately after stent implantation. The angiographic stented lumen diameter was measured using quantitative vessel analysis before, immediately after stenting, and at 6-week follow-up. Cross-section histopathology and area morphometry were performed. Results: Immediately poststenting, intravascular ultrasound revealed proximal dislocation of 5 of the 13 PET stents, whereas all metal stents were firmly embedded at the implantation site. At 6-week follow-up, three of the remaining PET stents were totally or subtotally occluded by organized thrombus, whereas all metal stents were patent. Compared with immediately poststenting, the angiographic lumen diameter within the five remaining PET stents was reduced by 30%, and that of the metallic stents was virtually unaltered (p < 0.02). This observation was confirmed by postmortem morphometry, wherein the PET-stented vessel segments a diameter stenosis of 40% was measured vs only 9% in the metallic stents (p < 0.0001). Conclusion: PET-stent deployment is difficult to control due to the lack of radiopacity of this stent. PET stents seem to be more thrombogenic and lead to significantly more neointimal proliferation than metallic stents
International Nuclear Information System (INIS)
He Xu; Gu Jianping; Lou Wensheng; Chen Liang; Chen Guoping; Su Haobo; Song Jinhua; Wang Tao; Xu Ke
2011-01-01
Objective: To discuss the application of retrograde popliteal artery puncturing under X-ray guidance in the interventional therapy for superficial femoral artery occlusion. Methods: Retrograde popliteal artery puncturing under X-ray guidance was carried out in nine patients with long-segment occlusion of superficial femoral artery as antegrade recanalization via femoral artery approach had failed in them. After retrograde route was successfully established, the balloon dilation and subsequent stent placement for occluded vessel were performed. Results: The technical success was obtained in all patients. The occluded superficial femoral arteries were reopened and the symptoms of intermittent claudication disappeared. No serious complications such as injuries of adjacent nerves or vessels occurred. The ankle-brachial index (ABI) increased from preoperative (0.38±0.13) to postoperative (0.92±0.11) with the difference being statistically significant (P<0.01). A follow-up period lasting for 2-16 months was conducted. Eleven months after the treatment, intermittent claudication recurred in one case, and CT angiography showed that the distal part of the stent was narrowed. The symptoms were improved after percutaneous transcatheter angioplasty was performed again. Conclusion: Retrograde popliteal artery puncturing under X-ray guidance is an effective and safe technique for the treatment of superficial femoral artery long-segment occlusion with stent placement, especially for patients in whom antegrade recanalization via femoral artery approach fails. (authors)
Dual origin of the left vertebral artery: extracranial MRA and CTA findings.
LENUS (Irish Health Repository)
Tobin, W Oliver
2012-02-01
A 48-year-old man presented with a posterior circulation stroke secondary to left lateral medullary infarction. Contrast-enhanced magnetic resonance angiography (CEMRA) revealed 40-45% intracranial left vertebral artery stenosis, likely atherosclerotic in nature. CEMRA and subsequent computed tomography angiography also identified a duplicate origin of the left vertebral artery. The importance of recognition of this rare anatomical variant, its potential contribution to stroke aetiology, and the advantage of non-invasive vascular imaging prior to catheter angiography is emphasised.
Clegg, Stacey; Aghel, Arash; Rogers, R Kevin
2014-08-01
Excisional atherectomy alone or followed by stenting is considered an appropriate treatment strategy for patients with lifestyle-limiting claudication due to obstructive infra-inguinal peripheral arterial disease (Ramaiah et al., J Endovasc Ther 2006;13:592-6021). We present a case of a 69-year-old man with eccentric severely calcified disease of the superficial femoral artery (SFA) treated with excisional atherectomy followed by stenting with an interwoven nitinol stent. The procedure was complicated by extravascular stent migration associated with a contained rupture presenting 30 days after the intervention. The complication was successfully treated with a stent graft. Although rare, pseudoaneurysms have been reported at the site of prior atherectomy; however, this case is the first description of a contained rupture post atherectomy associated with erosion of a nitinol stent into an extra-luminal position. The mechanism and management of this complication are discussed. © 2014 Wiley Periodicals, Inc.
A new kind of 32P stent used for prevention of the restenosis after PTCA in rabbit iliac arteries
International Nuclear Information System (INIS)
Gao Dongsheng; Chen Runfen; Mao Jialiang; Huang Dingjiu
2003-01-01
Objective: To evaluate the effect and the mechanism of a new kind of 32 P stents used for prevention of the restenosis after percutaneous transluminal coronary angioplasty (PTCA); to observe the 'edge effect' caused by radioactive stents. Methods: Six 32 P-β-emitting stents made by compound plating, paired with 6 31 P nonradioactive(control) stents, were placed separately, one in one iliac artery in 6 rabbits, respectively. Animals were sacrificed after 30 d. Angiography, morphometry and immunohistochemistry work-up were performed. Results: There were no aneurysm or thrombosis in the arteries with stents placed. Morphometric measurements demonstrated that the mean minimum lumen diameter (MLD) was greater in 32 P stents than that in control stents (P 32 P stents was greater than that in control stents, but the later had marked neointimal area than the former (P 32 P-β-emitting stents made by compound plating could prevent in-stent restenosis significantly by inhibiting the neointimal growth even with low radioactivity; and it is safe, cheap and easy to make. But an unexpected increase in neointimal response, the so-called 'edge effect', was observed in the study
Gao, Bulang; Safain, Mina G; Malek, Adel M
2015-04-01
Although intracranial stenting has been associated with in-stent stenosis, the vascular response of cerebral vessels to the deployment of the Enterprise vascular reconstruction device is poorly defined. To evaluate the change in parent vessel caliber that ensues after Enterprise stent placement. Seventy-seven patients with 88 aneurysms were treated using Enterprise stent-assisted coil embolization and underwent high-resolution three-dimensional rotational angiography followed by three-dimensional edge-detection filtering to remove windowing-dependence measurement artifact. Orthogonal diameters and cross-sectional areas (CSAs) were measured proximal and distal on either side of the leading stent edge (points A, B), trailing stent edge (points D, E), and at mid-stent (point C). Enterprise stent deployment caused an instant increase in the parent artery CSA by 8.98% at D, which was followed 4-6 months later by significant in-stent stenosis (15.78% at A, 27.24% at B, 10.68% at C, 32.12% at D, and 28.28% at E) in the stented artery. This time-dependent phenomenon showed resolution which was complete by 12-24 months after treatment. This target vessel stenosis showed significant age dependence with greater response in the young. No flow-limiting stenosis requiring treatment was observed in this series. Use of the Enterprise stent is associated with a significant dynamic and spontaneously resolvable age-dependent in-stent stenosis. Further study is warranted on the clinical impact, if any, of this occurrence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Clinical effectiveness of secondary interventions for restenosis after renal artery stenting
Simone, Thomas A.; Brooke, Benjamin S.; Goodney, Philip P.; Walsh, Daniel B.; Stone, David H.; Powell, Richard J.; Cronenwett, Jack L.; Nolan, Brian W.
2013-01-01
Objective Secondary interventions for renal artery restenosis (RAS) after renal artery stenting are common, despite limited data about their effectiveness. This study was designed to evaluate the outcomes of endovascular treatment of recurrent RAS. Methods We conducted a retrospective review of patients who underwent renal artery stenting between 2001 and 2011 at Dartmouth-Hitchcock Medical Center. Patients who required secondary interventions were compared with control patients who underwent only primary interventions for RAS. Multivariate regression models were used to identify factors associated with successful outcomes, as measured by changes in blood pressure, estimated glomerular filtration rate, and number of antihypertensive medications required. Results Sixty-five secondary (57 patients) renal interventions were undertaken for recurrent RAS associated with progressive hypertension or renal dysfunction and compared with outcomes after 216 primary (180 patients) renal artery stenting procedures. Patients undergoing primary vs secondary interventions did not differ significantly in the number of preoperative antihypertensive medications used, comorbid conditions, or blood pressure. All primary and secondary interventions were performed with stents and showed no difference in procedural complications. At a mean follow-up of 23 months (range, 1–128 months), similar improvements in renal function and blood pressure were found between patients undergoing primary and secondary interventions, and there was no difference in rates of restenosis or survival between cohorts. Regression models showed that the use of embolic protection devices was associated with improved renal function after primary (odds ratio [OR], 2.0; 95% confidence interval [CI], 1.1–3.8; P < .05) and secondary (OR, 4.7; 95% CI, 1.7–12.5; P < .05) interventions, whereas statin therapy was associated with improved renal (OR, 2.0; 95% CI, 1.3–3.2; P < .05) and blood pressure response (OR, 4
Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K
2009-01-01
Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis or=50% in-stent stenosis, a PSV >or=190 had 88% sensitivity, 95% specificity, a 98% positive predictive value (PPV), and a 72% negative predictive value (NPV); for Vr, a ratio of >1.50 had 93% sensitivity, 89% specificity, a 96% PPV, and a 81% NPV. To detect >or=80% in-stent stenosis, a PSV >or=275 had 97% sensitivity, 68% specificity, a 67% PPV, and a 97% NPV; a Vr ratio >or=3.50 had 74% sensitivity, 94% specificity, a 77% PPV, and a 88% NPV. Combining a PSV >or=275 and a Vr >or=3.50 to determine >or=80% in-stent stenosis had 74% sensitivity, 94% specificity, a 88% PPV, and a 85% NPV; odds ratio was 42.17 (95% confidence interval, 10.20-174.36, P or=80% in-stent stenosis. A significant drop in ABI (>0.15) correlated with a >62% in-stent stenosis, although the adjusted correlation coefficients was low (R(2) = 0.31, P = .02). PSV and Vr appear to have a significant role in predicting in-stent stenosis. To determine >or=80% stenosis, combining PSV >or=275 cm/s and Vr >or=3.50 is highly specific and predictive.
Zientek, D M; Rodgers, G P
1999-10-01
The creation of a pseudolesion after guidewire placement in tortuous arterial segments is a well recognized phenomenon. Intravascular ultrasound has been useful in assessing deployment of intracoronary stents and equivocal angiographic findings. We present a case in which a pseudolesion was not observed until after placement of an intracoronary stent. Intravascular ultrasound demonstrated no dissection or significant lesion; however, there was focal calcification just distal to the stent providing a substrate for the distorted vessel architecture. The lesion resolved with removal of the guidewire.
Ederle, J.; Davagnanam, I.; Worp, H.B. van der; Venables, G.S.; Lyrer, P.A.; Featherstone, R.L.; Brown, M.M.; Jager, H.R.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,
2013-01-01
BACKGROUND: Findings from randomised trials have shown a higher early risk of stroke after carotid artery stenting than after carotid endarterectomy. We assessed whether white-matter lesions affect the perioperative risk of stroke in patients treated with carotid artery stenting versus carotid
Institute of Scientific and Technical Information of China (English)
张新霞; 崔长琮; 李江; 崔翰斌; 徐仓宝; 朱参战
2002-01-01
Objective To investigate the effect of gelatin coated Platinium-Iridium stent absorbed c-myc antisense oligodeoxynucleotide (ASODN) on smooth muscle cells apoptosis in a normal rabbit carotid arteries. Methods Gelatin coated Platinium-Iridium stents were implanted in the right carotid arteries of 32 rabbits under vision. Animals were randomly divided into control group and treated group receiving c-myc ASODN (n=16, respectively). On 7, 14, 30 and 90 days following the stenting procedure ,morphometry for caculation of neointimal area and mean neointimal thickness were performed.The expression of c-myc protein was detected by immunohistochemical method. Apoptotic smooth muscle cells was detected by terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL). Results At 7 and 14 days after stenting,there were no detectable apoptotic cells in both groups. The apoptotic cells occurred in the neointima 30 and 90 days after stenting, and the number of apoptotic cells at 30 days were less [4.50±1.29 vs 25.75±1.89 (number/0.1mm2)] than that at 90 days [13.50±1.91 vs 41.50±6.46 (number/0.1mm2)]. Meanwhile c-myc ASODN induced more apoptotic cells than the control group(P<0.0001). c-myc protein expression was weak positive or negative in treated group and positive in control group.Conclusion c-myc ASODN can induce smooth muscle cells apoptosis after stenting in normal rabbit carotid arteries,and it can be used to prevent in-stent restenosis.
Cognitive changes after carotid artery stenting
International Nuclear Information System (INIS)
Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M.; Supprian, T.; Falkai, P.; Reith, W.
2006-01-01
We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9±1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)
Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki
2018-01-15
The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.
Assessment of a Polyester-Covered Nitinol Stent in the Canine Aorta and Iliac Arteries
International Nuclear Information System (INIS)
Castaneda, Flavio; Ball-Kell, Susan M.; Young, Kate; Li Ruizong
2000-01-01
Purpose: To evaluate the patency and healing characteristics of a woven polyester fabric-covered stent in the canine model.Methods: Twenty-four self-expanding covered stents were placed in the infrarenal aorta and bilateral common iliac arteries of eight dogs and evaluated at 1 (n = 2), 3 (n = 2), and 6 (n = 4) months. Stent assessment was done using angiography prior to euthanasia, and light and scanning electron microscopy.Results: Angiographically, just prior to euthanasia, 8 of 8 aortic and 14 of 16 iliac endovascular covered stents were patent. Histologically, the stented regions showed complete endothelialization 6 months after graft implantation. A neointima had formed inside the stented vessel regions resulting in complete encasement of the fabric-covered stent by 3 months after graft implantation. Medial compression with smooth muscle cell atrophy was present in all stented regions. Explanted stent wires, examined by scanning electron microscopy, showed pitting but no cracks or breakage.Conclusion: The covered stent demonstrated predictable healing and is effective in preventing stenosis in vessels 10.0 mm or greater in diameter but does not completely preclude stenosis in vessels 6.0 mm or less in diameter
Delayed symptoms and death after minor head trauma with occult vertebral artery injury.
Auer, R N; Krcek, J; Butt, J C
1994-01-01
Head injury without loss of consciousness is seldom accompanied by grave complications. We report the case of an 18 year old cyclist who was struck by a car in a minor road traffic accident, suffered minor head injury without loss of consciousness, and died unexpectedly seven weeks later with vomiting and coma. Necropsy revealed an expanding cerebellar infarct and vertebral artery thrombosis, superimposed on an old dissecting intramural haematoma of the right vertebral artery in the atlantoax...
International Nuclear Information System (INIS)
Galanakis, Nikolaos; Kontopodis, Nikolaos; Peteinarakis, Ioannis; Kehagias, Elias; Ioannou, Christos V.; Tsetis, Dimitrios
2017-01-01
PurposeThe purpose of this study is to accentuate the efficacy of direct stenting (stent placement without predilatation of the lesion) in patients with acute lower limb arterial ischemia (ALLI).Materials and MethodsBetween January 2010 and September 2015, 16 patients (11 men and 5 women) underwent direct stenting of acute arterial occlusions. All patients had contraindication for surgical revascularization or catheter-directed thrombolysis. According to SVS/ISCVS Classification, six patients had IIa and ten patients IIb ALLI. The occlusions were located in CIA, EIA, SFA, or popliteal artery. Mean follow-up time with clinical examination and color Duplex ultrasonography was 37.6 months (range 1–72). We analyzed the technical and clinical outcomes of the procedures, as well the complications and patency rates.ResultsTechnical success was achieved in all patients (16/16) and there was significant clinical improvement in 15 patients. There was neither distal embolization nor procedure-related complications. During the 6 years of follow-up, four patients died due to non-procedure-related causes and there were two minor and one major amputations. The primary patency rates and the amputation-free survival rates were 93.7 and 87% at 1 year, 75.2 and 71.2% at 3 years, and 75.2 and 62.3%, respectively, at 6 years.ConclusionsDirect stenting may be a valuable alternative procedure for acute arterial occlusions in selected cases with high technical success and significant clinical improvement.Level of EvidenceLevel 4, Case Series.
Energy Technology Data Exchange (ETDEWEB)
Galanakis, Nikolaos [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece); Kontopodis, Nikolaos [University of Crete Medical School, Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital Heraklion (Greece); Peteinarakis, Ioannis; Kehagias, Elias [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece); Ioannou, Christos V. [University of Crete Medical School, Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital Heraklion (Greece); Tsetis, Dimitrios, E-mail: tsetis@med.uoc.gr [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece)
2017-02-15
PurposeThe purpose of this study is to accentuate the efficacy of direct stenting (stent placement without predilatation of the lesion) in patients with acute lower limb arterial ischemia (ALLI).Materials and MethodsBetween January 2010 and September 2015, 16 patients (11 men and 5 women) underwent direct stenting of acute arterial occlusions. All patients had contraindication for surgical revascularization or catheter-directed thrombolysis. According to SVS/ISCVS Classification, six patients had IIa and ten patients IIb ALLI. The occlusions were located in CIA, EIA, SFA, or popliteal artery. Mean follow-up time with clinical examination and color Duplex ultrasonography was 37.6 months (range 1–72). We analyzed the technical and clinical outcomes of the procedures, as well the complications and patency rates.ResultsTechnical success was achieved in all patients (16/16) and there was significant clinical improvement in 15 patients. There was neither distal embolization nor procedure-related complications. During the 6 years of follow-up, four patients died due to non-procedure-related causes and there were two minor and one major amputations. The primary patency rates and the amputation-free survival rates were 93.7 and 87% at 1 year, 75.2 and 71.2% at 3 years, and 75.2 and 62.3%, respectively, at 6 years.ConclusionsDirect stenting may be a valuable alternative procedure for acute arterial occlusions in selected cases with high technical success and significant clinical improvement.Level of EvidenceLevel 4, Case Series.
Directory of Open Access Journals (Sweden)
Javier Almeida Gómez
2012-10-01
Full Text Available ResumenIntroducción y objetivos: La afectación significativa del tronco común izquierdo, es la más letal de las presentaciones de la enfermedad arterial coronaria. El tratamiento de elección, es la cirugía de derivación aorto-coronaria. En varios estudios multicéntricos, se sugiere la posibilidad de tratar la enfermedad de tronco mediante el intervencionismo coronario percutáneo con implantación de prótesis endoluminal o stent. El objetivo de esta investigación fue caracterizar la angioplastia percutánea con stent en el tronco principal de la arteria coronaria izquierda. Método: Se realizó un estudio observacional, descriptivo y transversal en 21 pacientes con angioplastia percutánea con stent en el tronco principal de la arteria coronaria izquierda, realizadas en el laboratorio de Hemodinámica y Cardiología Intervencionista del Hospital "Hermanos Ameijeiras", entre enero 2010 y julio 2011. Resultados: No existió diferencia significativa en el sexo. Predominó el grupo de edad entre 50-64 años (47,6 % y el color de la piel blanca (76,19 %. El factor de riesgo cardiovascular más encontrado fue la HTA (85,71 %, seguido de dislipidemia (47,61 %. El diagnóstico más observado fue la angina de esfuerzo estable, 14 casos (66,66 %. La lesión en el cuerpo del tronco (12 pacientes, 57,1 %, fue la más encontrada, seguida de la ostial (8 casos. El tipo de stent más utilizado fue el liberador de fármacos (61,9 %, y solamente 4 pacientes presentaban troncos protegidos quirúrgicamente. Conclusiones: La mayor cantidad de casos fueron electivos, con predominio de los troncos no protegidos. El factor de riesgo coronario más encontrado fue la HTA. Se encontró asociación significativa entre la diabetes mellitus y la localización ostial de la lesión tratada. / AbstractIntroduction and Objectives: Significant impairment of the left main coronary artery is the most lethal presentation of coronary artery disease. The treatment of choice
Jabara, Refat; Chronos, Nicolas; Tondato, Fernando; Conway, Damian; Molema, Warner; Park, Kenneth; Mabin, Tom; King, Spencer; Robinson, Keith
2006-08-01
The goal of this study was to evaluate a new drug-eluting stent (DES) comprising a bioabsorbable polymer eluting a moderate dose of paclitaxel in a clinically relevant animal model. Although DES limit restenosis, adverse vascular pathologies and toxicities continue to be of major concern. Optimization of DES components, especially completely absorbable polymers, may reduce these toxicities. Bare-metal (BM), absorbable polymer coating only (POLY), and polymer-based paclitaxel-eluting (PACL) stents were implanted in porcine coronary arteries using intravascular ultrasound (IVUS) to optimize stent apposition. The dose density of paclitaxel was 0.30-0.35 mcg/mm2, with in vitro elution studies demonstrating a gradual elution over 6-8 weeks. The animals were terminated at 1 week, 1 month and 3 months. Histopathologic and histomorphometric analyses were perform. The arteries with PACL showed extensive smooth muscle cell necrosis at 1 week and poor apposition of stent struts at 1 month (malapposition measured as gap width between strut and internal elastic lamina), with greater gap width compared to the BM and POLY groups (0.22 mm +/- 0.02 vs. 0.03 mm +/- 0.02 and 0.02 mm +/- 0.01, respectively; p stent malapposition and late neointimal thickening. Since the therapeutic window for paclitaxel may be narrower than currently inferred, thorough preclinical testing coupled with the polymer development process for stents eluting paclitaxel is needed.
Owolabi, Mayowa O; Agunloye, Atinuke M; Ogunniyi, Adesola
2014-01-01
Chronic changes in flow rate through arteries produce adjustment of arterial diameters. We compared the relationship between flow velocity and diameter in the carotid and in the vertebral arteries of stroke patients. Using triplex ultrasonography, the internal diameter and flow velocities of the common carotid, internal carotid, and vertebral arteries of 176 consecutive stroke patients were measured. Correlations were examined with Pearson's statistics at an alpha level of 0.05. Mean age of the patients was 59.3 ± 12 years, and 66% had cerebral infarcts. Diameter and blood flow velocities showed significant negative correlations (-0.115 ≥ r ≥ -0.382) in the carotid arteries on both sides, but positive correlations (0.211 ≤ r ≤ 0.320) in the vertebral arteries, even after controlling for age, gender, and blood pressure. Our study demonstrated different diameter/flow relationships in the carotid and the vertebral arteries of stroke patients, which may suggest pathologic changes in the adaptive processes governing vessel diameter and growth, especially in the carotid arteries. Copyright © 2013 Wiley Periodicals, Inc.
International Nuclear Information System (INIS)
Funovics, M.A.; Lackner, B.; Cejna, M.; Peloschek, P.; Sailer, J.; Philipp, M.O.; Maca, T.; Ahmadi, A.; Minar, E.; Lammer, J.
2002-01-01
Purpose: To investigate initial and long-term success rate after percutaneous treatment of iliac artery occlusion with angioplasty and stent deployment. To investigate the influence of vascular comorbidity, lesion length, stent placement and lesion coverage as possible predictors of outcome. Methods: Between January 1994 and December 1999, 80 iliac recanalizations were performed on 78 patients, median age 61.1 ±11.5 (SD) years. All patients were followed up by clinical examinations, duplex ultrasound and intravenous digital subtraction angiography. Mean follow-up time was 2.0 ± 1.53 (SD) years.Multivariate Cox regression analysis was used to determine the influence of cofactors on patency. Results: One, 2 and 4 years after recanalization, primary patency was 78.1%, 74.5% and 64.0%; secondary patency was 88.8%, 88.8% and 77.9%, respectively.Patients with shorter occlusions, complete lesion coverage and patent ipsilateral femoral arteries had significantly longer patency rates.Complications included inguinal hematoma (n=1), technical failure (n=3) aortic dissection (n=1), embolic occlusions (n=7), gluteal claudication (n=1) and genital necrosis after subsequent urethral surgery in one patient with contralateral occlusion and ipsilateral overstenting of the internal iliac artery with subsequent stenosis. Complications were of permanent clinical significance in seven of 78 (9%) of the patients. In 17 (22%) cases, percutaneous reintervention was performed with angioplasty in the stent (n=16) or deployment of a new stent (n=1). Conclusion: Endoluminal stent placement has its place in an interdisciplinary therapeutic approach as a viable therapeutic alternative to major transabdominal bypass surgery and can be performed with comparable complication rates. Patients with short occlusions, patent femoral arteries, and stents covering the entire occlusion have significant longer patency
International Nuclear Information System (INIS)
Abbott, J. Dawn; Brennan, Joseph J.; Remetz, Michael S.
2004-01-01
Internal mammary artery (IMA) to pulmonary artery (PA) fistula is a rare complication of coronary artery bypass grafting (CABG) that may present as myocardial ischemia. We describe a case of left IMA-to-PA fistula treated with balloon expandable coronary polytetrafluoroethylene (PTFE) graft stents and review previously reported cases of this entity
Energy Technology Data Exchange (ETDEWEB)
Wan, Chih-Cheng; Chen, David Yen-Ting; Tseng, Ying-Chi; Lee, Kun-Yu; Chiang, Chen-Hua; Chen, Chi-Jen [Taipei Medical University, Department of Radiology, Shuang-Ho Hospital, New Taipei City (China); Taipei Medical University, School of Medicine, College of Medicine, Taipei (China); Yan, Feng-Xian [Taipei Medical University, Department of Radiology, Shuang-Ho Hospital, New Taipei City (China)
2017-08-15
No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS. We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated. The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P <.05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P <.001), overall nonstenting vascular (P <.001), and ipsilateral PCA (P <.05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings. FVHs could be a critical predictor of a significant increase in CBF after IAS. (orig.)
International Nuclear Information System (INIS)
Wan, Chih-Cheng; Chen, David Yen-Ting; Tseng, Ying-Chi; Lee, Kun-Yu; Chiang, Chen-Hua; Chen, Chi-Jen; Yan, Feng-Xian
2017-01-01
No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS. We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated. The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P <.05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P <.001), overall nonstenting vascular (P <.001), and ipsilateral PCA (P <.05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings. FVHs could be a critical predictor of a significant increase in CBF after IAS. (orig.)
Auxetic coronary stent endoprosthesis
DEFF Research Database (Denmark)
Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar
2014-01-01
BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...
Tekieli, Lukasz; Pieniazek, Piotr; Musialek, Piotr; Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Trystula, Mariusz; Moczulski, Zbigniew; Dzierwa, Karolina; Paluszek, Piotr; Podolec, Piotr
2012-06-01
To evaluate the safety and efficacy of a balloon-mounted drug-eluting stent (DES) for recurrent carotid in-stent stenosis (ISS). As part of our targeted carotid artery stenting (TARGET-CAS) protocol, neurological and ultrasound evaluations have been performed at 3, 6, and 12 months and then annually since 2001 in all carotid stent patients. For angiographically-confirmed >70% ISS, balloon angioplasty was performed as a first-line treatment. Recurrent ISS was treated with a 4.0-mm zotarolimus-eluting coronary stent (ZES) that was postdilated according to intravascular ultrasound imaging. Among the 1350 neuroprotected CAS procedures performed between January 2001 and March 2011, there were 7 (0.52%) patients (5 men; ages 51-72 years), all neurologically asymptomatic, with >70% recurrent ISS that occurred at 5 to 11 months after the initial balloon angioplasty treatment for ISS. ZES implantation under distal embolic protection was technically successful and uncomplicated. Angiographic stenosis was reduced from 84.6%±7.5% to 10.7%±3.6% (p<0.01). In 5 patients with ZES implanted fully within the self-expanding carotid stent, duplex ultrasound follow-up (mean 17 months, range 6-36) revealed no evidence of restenosis or stent fracture/deformation. In the 2 other patients, the ZES had been implanted for distal edge ISS such that the ZES protruded beyond the original carotid stent. This protruding segment of the ZES demonstrated deformation/kinking in both; in one, this led to symptomatic stent occlusion. The use of coronary ZES in the treatment of recurrent carotid ISS is feasible and appears effective provided the ZES is placed entirely within the original stent. Placement of a coronary ZES outside the carotid stent scaffold should be avoided.
Vertebral Artery Caught in the Fracture Gap after Traumatic C2/3 Spondylolisthesis
Directory of Open Access Journals (Sweden)
Ralf Henkelmann
2017-01-01
Full Text Available Background Context. Patient with a C2 fracture and entrapment of the right vertebral artery in the fracture gap. Purpose. Presentation of a case with follow-up until end of treatment. Study Design. Case report. Methods. A 25-year-old woman was brought into our emergency room after falling while riding a horse. She complained of pain in the cervical spine. Clinical examinations showed local tenderness at the upper cervical spine and painful impairment of the mobility of the neck, with no signs of neurological impairment. Radiological diagnostics revealed a traumatic C2/3 spondylolisthesis. A computer tomography (CT angiographic scan showed a dislocation of the right vertebral artery into the fracture gap without injury to the artery. Open reduction and osteosynthesis were considered of too high risk. Therefore, we conducted fracture treatment with closed reduction and halo fixation. After removal of the halo fixator, the patient was given a soft cervical collar and was advised to rest for additional 6 weeks before beginning gradual activity. Results. Conventional follow-up revealed osseous consolidation and a CT angiographic scan showed consistent blood flow to the artery. Conclusion. Halo fixation was a safe and effective therapy strategy in the case of vertebral artery entrapment after traumatic C2 spondylolisthesis.
Lal, Brajesh K; Beach, Kirk W; Roubin, Gary S; Lutsep, Helmi L; Moore, Wesley S; Malas, Mahmoud B; Chiu, David; Gonzales, Nicole R; Burke, J Lee; Rinaldi, Michael; Elmore, James R; Weaver, Fred A; Narins, Craig R; Foster, Malcolm; Hodgson, Kim J; Shepard, Alexander D; Meschia, James F; Bergelin, Robert O; Voeks, Jenifer H; Howard, George; Brott, Thomas G
2012-09-01
In the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST), the composite primary endpoint of stroke, myocardial infarction, or death during the periprocedural period or ipsilateral stroke thereafter did not differ between carotid artery stenting and carotid endarterectomy for symptomatic or asymptomatic carotid stenosis. A secondary aim of this randomised trial was to compare the composite endpoint of restenosis or occlusion. Patients with stenosis of the carotid artery who were asymptomatic or had had a transient ischaemic attack, amaurosis fugax, or a minor stroke were eligible for CREST and were enrolled at 117 clinical centres in the USA and Canada between Dec 21, 2000, and July 18, 2008. In this secondary analysis, the main endpoint was a composite of restenosis or occlusion at 2 years. Restenosis and occlusion were assessed by duplex ultrasonography at 1, 6, 12, 24, and 48 months and were defined as a reduction in diameter of the target artery of at least 70%, diagnosed by a peak systolic velocity of at least 3·0 m/s. Studies were done in CREST-certified laboratories and interpreted at the Ultrasound Core Laboratory (University of Washington). The frequency of restenosis was calculated by Kaplan-Meier survival estimates and was compared during a 2-year follow-up period. We used proportional hazards models to assess the association between baseline characteristics and risk of restenosis. Analyses were per protocol. CREST is registered with ClinicalTrials.gov, number NCT00004732. 2191 patients received their assigned treatment within 30 days of randomisation and had eligible ultrasonography (1086 who had carotid artery stenting, 1105 who had carotid endarterectomy). In 2 years, 58 patients who underwent carotid artery stenting (Kaplan-Meier rate 6·0%) and 62 who had carotid endarterectomy (6·3%) had restenosis or occlusion (hazard ratio [HR] 0·90, 95% CI 0·63-1·29; p=0·58). Female sex (1·79, 1·25-2·56), diabetes (2·31, 1·61-3·31
International Nuclear Information System (INIS)
Yokota, Hiroyuki; Atsumi, Takahiro; Araki, Takashi; Fuse, Akira; Sato, Hidetaka; Kawai, Makoto; Yamamoto, Yasuhiro
2007-01-01
Vertebral artery injury associated with non-penetrating cervical trauma is rare. We report 11 cases of vertebral artery injury diagnosed with magnetic resonance imaging (MRI) after blunt trauma to the cervical spine and discuss about the importance of MRI in the diagnosis of this injury. Seven cases were caused by motor vehicle accidents, three by diving accidents, and one by static compression of the neck. All of the patients had documented cervical spine fractures and dislocations. In three patients, the diagnosis of complete occlusion of the vertebral artery was made on the basis of MRI and digital subtraction angiography (DSA). In the other patients, mural injuries of the vertebral artery were demonstrated with DSA. These 11 patients presented with acute, nonspecific changes in neurological status. Two had infarctions of the cerebellum and brainstem. None were treated with anticoagulants. All of them survived and were discharged to other hospitals for physical and occupational therapy. Although DSA remains the gold standard for diagnosing vertebral artery injuries, MRI is a newer modality for assessing cervical cord injury, and it may be useful for evaluating the presence of vertebral injury after blunt cervical spine trauma. (author)
Directory of Open Access Journals (Sweden)
Binit Sureka
2015-01-01
Full Text Available Purpose: To study the location, origin, size and relationship of the vertebral artery and the transverse foramina in the lower cervical spine by computed tomographic angiography (CTA measurements in the Indian population. Materials and Methods: A retrospective review of multi-detector CT (MDCT cerebral angiography scans was done between June 2011 and February 2014. A total of 120 patients were evaluated. The diameter of the vertebral artery (AL and the shortest distance between the vertebral artery and the medial (M, lateral (L, anterior (A, and posterior (P borders of transverse foramen were studied. In addition, the shortest distance between the vertebral artery and pedicle (h was also analyzed. Statistical Analysis: The means and their standard deviations (SD were calculated in both the sexes. The t-tests were performed to look for significant sexual difference. Results: The largest vertebral artery diameter (AL was at level C7 on the right side (3.5 ± 0.8 and at the level of C5 on the left side (3.7 ± 0.4. Statistically significant difference between males and females were seen at levels C4, C5, and C7. The diameter of the vertebral artery was smaller in females than males. The L value was greater than other parameters (M, A, P at the same level in all the measurements. The h value was greatest at C6 level and shortest at C5. Conclusion: CTA is necessary before pedicle screw fixation due to variation in measurements at all levels. The highest potential risk of vertebral artery injury during cervical pedicle screw implantation may be at C5, then at C4, and the safest is at C7.
International Nuclear Information System (INIS)
Wang Wu; Li Minghua; Li Yongdong; Gu Binxian; Fang Chun; Tan Huaqiao; Wang Ju; Zhang Peilei
2010-01-01
Objective: To evaluate the efficacy and mid-term follow-up results of endovascular treatment with Willis covered stent for traumatic pseudoaneurysms located in the internal carotid artery (ICA). Methods: ICA angiography was performed in 38 patients with traumatic brain and neck injury. Of the 38 patients, 13 delayed traumatic pseudoaneurysms were found. All the pseudoaneurysms were treated with Willis covered stents. Follow-up angiography was performed at 1, 3, 6 and 12 months after the procedure, and the results were categorized as complete or incomplete occlusion. Clinical manifestations were graded as full recovery, improvement, unchanged and aggravation. Results: Willis covered stent placement was technically successful in all traumatic pseudoaneurysms. No procedure-related complications occurred. The initial angiographic results showed a complete occlusion in 9 patients, and an incomplete occlusion in 4. The angiographic follow-up within 3-12 months exhibited a complete occlusion in 12 patients and the parent arteries remained patency in all patients. The clinical follow-up observation demonstrated that full recovery was obtained in 11 patients, clinical improvement in one, and unchanged condition in one. No morbidity or mortality occurred. Conclusion: Willis covered stent implantation is a feasible and practical treatment for traumatic pseudoaneurysms located in the ICA. This technique can well preserve the parent artery with excellent therapeutic results. (authors)
Neumann, C; Gschwendtner, M; Karnel, F; Mair, J; Dorffner, G; Dorffner, R
2005-01-01
To evaluate the technical feasibility of the implantation of the monorail RX Herculink system into the renal arteries without pre-dilatation. Forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink stent. The mean grade of the stenosis was 83.8 %, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). In 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30 % were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 +/- 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 +/- 0.0. Implantation of the RX Herculink stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies.
Harada, Kei; Kakumoto, Kosuke; Oshikata, Shogo; Fukuyama, Kozo
2018-06-01
Carotid artery stenting (CAS) with proximal occlusion effectively prevent distal cerebral embolism by flow arrest at internal carotid artery (ICA); however, the method can expose antegrade flow at ICA due to incomplete flow arrest. The aim of this study was to identify predictors of antegrade flow during CAS with proximal protection. We retrospectively analyzed clinical and angiographic data among 143 lesions treated with CAS with proximal protection by occluding the common carotid artery (CCA) and external carotid artery (ECA). Flow arrest or antegrade flow at ICA was confirmed by contrast injection during proximal protection. Antegrade flow at ICA was observed in 12 lesions (8.4%). Compared with lesions in which flow arrest of ICA was achieved, the diameter of the superior thyroid artery (STA) was significantly larger (2.4 ± 0.34 vs. 1.4 ± 0.68 mm, p protection should be combined with proximal protection for the lesions with antegrade flow to prevent distal migration of the carotid debris.
Directory of Open Access Journals (Sweden)
Song Cui
2014-01-01
Full Text Available Endoglin/CD105 is an accessory protein of the transforming growth factor-β receptor system that plays a critical role in proliferation of endothelial cells and neovasculature. Here, we aimed to assess the effect of novel stents coated with antibodies to endoglin (ENDs on coronary neointima formation. Thirty ENDs, thirty sirolimus-eluting stents (SESs, and thirty bare metal stents (BMSs were randomly assigned and placed in the coronary arteries in 30 juvenile pigs. Histomorphometric analysis and scanning electron microscopy were performed after stent implantation. Our results showed that after 7 days, there was no difference in the neointimal area and percent area stenosis in ENDs compared with SMSs or BMSs. After 14 days, the neointima area and percent area stenosis in ENDs were markedly decreased than those in BMSs or SESs (P<0.05. Moreover, the percentage of reendothelialization was significantly higher in ENDs than that in SESs or BMSs (P<0.01 at 7 and 14 days. The artery injury and the inflammation scores were similar in all groups at 7 and 14 days. In conclusion, our results demonstrated for the first time to our knowledge that endoglin antibody-coated stents can markedly reduce restenosis by enhancing reendothelialization in the porcine model and potentially offer a new approach to prevent restenosis.
Directory of Open Access Journals (Sweden)
Menozzi Mila
2012-10-01
Full Text Available Abstract Dual antiplatelet treatment with aspirin and clopidogrel is the antithrombotic treatment recommended after an acute coronary syndrome and/or coronary artery stenting. The evidence for optimal antiplatelet therapy for patients, in whom long-term treatment oral anticoagulation is mandatory, is however scarce. To evaluate the safety and efficacy of the various antithrombotic strategies adopted in this population, we reviewed the available evidence on the management of patients receiving oral anticoagulation, such as a vitamin-k-antagonists, referred for coronary artery stenting. Atrial fibrillation is the most frequent indication for oral anticoagulation. The need of starting antiplatelet therapy in this clinical scenario raises concerns about the combination to choose: triple therapy with warfarin, aspirin, and a thienopyridine being the most frequent and advised. The safety of this regimen appeared suboptimal because of an increased risk in hemorrhagic complications. On the other hand, the combination of oral anticoagulation and an antiplatelet agent is suboptimal in preventing thromboembolic events and stent thrombosis; dual antiplatelet therapy may be considered only when a high hemorrhagic risk and low thromboembolic risk are perceived. Indeed, the need for prolonged multiple-drug antithrombotic therapy increases the bleeding risks when drug eluting stents are used. Since current evidence derives mainly from small, single-center and retrospective studies, large-scale prospective multicenter studies are urgently needed.
An interesting case report of vertebral artery dissection following polytrauma
Directory of Open Access Journals (Sweden)
Vikas Acharya
2016-01-01
Conclusion: Our report displays select images related to this case report and emphasizes the consideration of routine imaging in head and neck traumatic injuries to diagnose internal carotid and/or vertebral artery dissections much earlier.
Energy Technology Data Exchange (ETDEWEB)
Chung, Seok Kyun; Kim, Jae Kyu; Yoon, Woong; Kim, Jeong; Park, Jin Gyoon; Kang, Heoung Keun; Choi, Soo JinNa [Chonnam National University Hospital School of Medicine, Gwangju (Korea, Republic of)
2003-09-01
To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence. Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of follow-up varied from 1 day to 73 months (mean, 23.8 months). Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence (p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the fontaine stage were not statistically significant indicators of recurrence. The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery.
International Nuclear Information System (INIS)
Chung, Seok Kyun; Kim, Jae Kyu; Yoon, Woong; Kim, Jeong; Park, Jin Gyoon; Kang, Heoung Keun; Choi, Soo JinNa
2003-01-01
To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence. Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of follow-up varied from 1 day to 73 months (mean, 23.8 months). Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence (p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the fontaine stage were not statistically significant indicators of recurrence. The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery
Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.
Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma
2016-01-01
Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.
Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan
2015-10-01
Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.
Cognitive changes after carotid artery stenting
Energy Technology Data Exchange (ETDEWEB)
Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Supprian, T.; Falkai, P.; Reith, W. [University of the Saarland, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)
2006-05-15
We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9{+-}1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)
Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey
2017-11-01
High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.
International Nuclear Information System (INIS)
Maleux, Geert; Bernaerts, Pauwel; Thijs, Vincent; Daenens, Kim; Vaninbroukx, Johan; Fourneau, Inge; Nevelsteen, Andre
2003-01-01
The purpose of this study was to evaluate the feasibility, safety and midterm outcome of elective implantation of the Carotid Wallstent (registered) in patients considered to be at high surgical risk. In a prospective study, 54 carotid artery stenoses in 51 patients were stented over a 24-month period. Three patients underwent bilateral carotid artery stenting. Institutional inclusion criteria for invasive treatment of carotid occlusive disease (carotid endarterectomy or carotid artery stenting) are patients presenting with a 70% or more symptomatic stenosis and those with an 80% or more asymptomatic stenosis having a life-expectancy of more than 1 year. All patients treated by carotid artery stenting were considered at high risk for carotid endarterectomy because of a hostile neck (17 patients-31.5%) or because of severe comorbidities (37 patients-68.5%). No cerebral protection device was used. Of the 54 lesions, 33 (61.1%) were symptomatic and 21 (38.8%) were asymptomatic. Follow-up was performed by physical examination and by duplex ultrasonography at 1 month, 6 months, 1 year and 2 years after the procedure. All 54 lesions could be stented successfully without periprocedural stroke. Advert events during follow-up (mean 13.9 ± 5.7 months) were non-stroke-related death in 6 patients (11.1%), minor stroke in 4 stented hemispheres(7.4%), transient ipsilateral facial pain in 1 patient (1.8%),infection of the stented surgical patch in 1 patient (1.8%) and asymptomatic in stent restenosis in 4 patients (7.4%). The percutaneous implantation of the Carotid Wallstent (registered) , even without cerebral protection device, appears to be a safe procedure with acceptable clinical and ultrasonographic follow-up results in patients at high surgical risk. But some late adverse events such as ipsilateral recurrence of non-disabling (minor) stroke or in stent restenosis still remain real challenging problems
Schönwald, U G; Jorczyk, U; Kipfmüller, B
2011-01-01
Stents are commonly used for the treatment of occlusive artery diseases in carotid arteries. Today, there is a controversial discussion as to whether duplex sonography (DS) displays blood velocities (BV) that are too high in stented areas. The goal of this study was to evaluate the effect of stenting on DS with respect to BV in artificial carotid arteries. The results of computational fluid dynamics (CFD) were also used for the comparison. To analyze BV using DS, a phantom with a constant flow (70 cm/s) was created. Three different types of stents for carotid arteries were selected. The phantom fluid consisted of 67 % water and 33 % glycerol. All BV measurements were carried out on the last third of the stents. Furthermore, all test runs were simulated using CFD. All measurements were statistically analyzed. DS-derived BV values increased significantly after the placement of the Palmaz Genesis stent (77.6 ± 4.92 cm/sec, p = 0.03). A higher increase in BV values was registered when using the Precise RX stent (80.1 ± 2.01 cm/sec, p CFD simulations showed similar results. Stents have a significant impact on BV, but no effect on DS. The main factor of the blood flow acceleration is the material thickness of the stents. Therefore, different stents need different velocity criteria. Furthermore, the results of computational fluid dynamics prove that CFD can be used to simulate BV in stented silicone tubes. © Georg Thieme Verlag KG Stuttgart · New York.
International Nuclear Information System (INIS)
Berkefeld, J.; Zanella, F.E.; Rosendahl, H.; Theron, J.G.; Guimaraens, L.; Treggiari-Venzi, M.M.
2002-01-01
A measurement system is proposed to evaluate reconstructive effects of carotid stents on the geometry of the carotid bifurcation and the course of the internal carotid artery. To describe deviations of the stenotic internal carotid artery (ICA) from the extended axis of the common carotid artery (CCA) the CCA-ICA angle is measured between the CCA midaxis and the midaxis of the stenotic ICA segment. Maximal extensions of ICA tortuosities perpendicular to the course of the CCA axis are defined as ICA offset. The measurements were applied to DSA images of 224 carotid stenoses to evaluate variation and correlation between the two parameters. Comparative pre- and post-stent evaluation was performed in two series of 55 and 31 carotid stenoses treated with Wallstents and in a historic control group of 35 stenoses treated with Strecker stents. Straight course of the ICA was associated with low angle and low offset values, whereas tortuous course of the ICA showed larger angle and offset. A moderate linear correlation between the two parameters was found. Corresponding to a straightening of the stented segment, Wallstents reduced mean angle and offset values significantly. In five cases of the second series of Wallstents, transferrals of curves above the distal stent end associated with kinks were observed, and offset remained constant or increased. Strecker stent implantation caused no significant changes of bifurcational geometry. The proposed parameters corresponded to visual aspects of ICA tortuosity and detected reconstructive effects of self-expanding Wallstents on the ICA course. The measurement system may provide a basis for geometric evaluation of different stent types or implantation concepts with the aim: to optimize anatomic recanalization results in tortuous high angle-high offset bifurcations. (orig.)
International Nuclear Information System (INIS)
Neumann, C.; Dorffner, R.; Gschwendtner, M.; Karnel, F.; Mair, J.; Dorffner, G.
2005-01-01
Purpose: to evaluate the technical feasibility of the implantation of the monorail RX Herculink trademark system into the renal arteries without pre-dilatation. Materials and methods: forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink trademark stent. The mean grade of the stenosis was 83.8%, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). Results: in 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30% were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 ± 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 ± 0.0. Conclusion: implantation of the RX Herculink trademark stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies. (orig.)
Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Ristl, Robin; Schoder, Maria
2013-10-08
The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long lesions remains unsatisfactory. In a prospective, randomized, single-blind, multicenter study, 141 patients with symptomatic peripheral arterial disease were assigned to treatment with heparin-bonded, covered stents (Viabahn 72 patients) or BMS (69 patients). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. Mean ± SD lesion length was 19.0 ± 6.3 cm in the Viabahn group and 17.3 ± 6.6 cm in the BMS group. Major complications within 30 days were observed in 1.4%. The 12-month primary patency rates in the Viabahn and BMS groups were: intention-to-treat (ITT) 70.9% (95% confidence interval [CI]: 0.58 to 0.80) and 55.1% (95% CI: 0.41 to 0.67) (log-rank test p = 0.11); treatment per-protocol (TPP) 78.1% (95% CI: 0.65 to 0.86) and 53.5% (95% CI: 0.39 to 0.65) (hazard ratio: 2.23 [95% CI: 1.14 to 4.34) (log-rank test p = 0.009). In lesions ≥20 cm, (TransAtlantic Inter-Society Consensus class D), the 12-month patency rate was significantly longer in VIA patients in the ITT analysis (VIA 71.3% vs. BMS 36.8%; p = 0.01) and the TPP analysis (VIA 73.3% vs. BMS 33.3%; p = 0.004). Freedom from target lesion revascularization was 84.6% for Viabahn (95% CI: 0.72 to 0.91) versus 77.0% for BMS (95% CI: 0.63 to 0.85; p = 0.37). The ankle-brachial index in the Viabahn group significantly increased to 0.94 ± 0.23 compared with the BMS group (0.85 ± 0.23; p stents compared with BMS in lesions ≥20 cm and for all lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare
Cohen, Jennifer L; Glickstein, Julie S; Crystal, Matthew A
2017-12-01
A 20-month-old boy with Williams syndrome had undergone multiple surgical and catheter-based interventions for resistant peripheral pulmonary arterial stenoses with eventual bilateral stent placement and conventional balloon angioplasty. He persistently developed suprasystemic right ventricular (RV) pressure. Angioplasty with a drug-coated balloon (DCB) was performed for in-stent restenosis and to remodel his distal pulmonary vessels bilaterally. This resulted in immediate improvement in the in-stent stenosis and resultant decrease in RV pressure. Follow-up catheterization two months later continued to show long-lasting improvement in the in-stent stenosis. We hypothesize that the anti-proliferative effects of DCBs may be of benefit in the arteriopathy associated with Williams syndrome. We report this as a novel use of a DCB in the pulmonary arterial circulation in a patient with Williams syndrome.
Energy Technology Data Exchange (ETDEWEB)
Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore; Rosa, Giuliana La; Corte, Giuseppe; Bajardi, Guido [University of Palermo, Vascular Surgery Unit (Italy)
2015-10-15
A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.
Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W.; Park, Seung-Jung
2016-01-01
OBJECTIVES The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD).
Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent
Energy Technology Data Exchange (ETDEWEB)
Pieper, Claus Christian, E-mail: Claus.christian.pieper@ukb.uni-bonn.de; Meyer, Carsten, E-mail: Carsten.Meyer@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany); Rudolph, Jens, E-mail: jens.rudolph@ukb.uni-bonn.de; Verrel, Frauke, E-mail: frauke.verrel@ukb.uni-bonn.de [University of Bonn, Department of Surgery (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de; Wilhelm, Kai E., E-mail: kai.wilhelm@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany)
2013-08-01
PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.
Energy Technology Data Exchange (ETDEWEB)
Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Manzi, Marco
2013-07-15
Purpose: To evaluate the efficacy and safety of “Direct Stent Puncture” technique for intraluminal stent recanalization in the femoro-popliteal segments. Methods and Materials: A cohort of diabetics who had symptomatic in-stent occlusion of the superficial femoral or popliteal arteries underwent endovascular recanalization. After antegrade failure, direct stent puncture technique was performed. The primary end-point was to efficacy assessment, intended as technical success and clinical improvement. The secondary end-point was safety assessment, intended as free of complication rate. Results: Fifty-four patients (37 men; 73.6 ± 8.5 years) underwent direct stent puncture technique, after several unsuccessful antegrade attempts to cross the occluded stent. Technical success for intraluminal stent recanalization was achieved in 53/54 (98.2%) of cases and failed in 1/54 (1.8%). Clinical improvement was obtained in 51/54 (94.4%) of cases, with regression of the clinical symptoms and improvement of the TcPO{sub 2}, from 3 ± 18 mmHg to 43 ± 11 mmHg after 15 days (p < 0.001). Free of complications rate was 92.5%. In 2/54 (3.7%) of cases distal embolization occurred, in 1/54 (1.9%) case a sudden vessel thrombosis was diagnosed after 12 hours and in 1/54 (1.9%) case hematoma at the stent puncture site was observed. Conclusions: Direct Stent Puncture technique is an efficacy and safety option for intraluminal stent recanalization in the femoro-popliteal segment in-stent occlusion.
Energy Technology Data Exchange (ETDEWEB)
Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)
2009-09-15
An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency
PICTORIAL ESSAY Is anomalous origin of the left vertebral artery ...
African Journals Online (AJOL)
Is anomalous origin of the left vertebral artery indeed a rare finding? Braham van der Merwe, Christelle Ackermann, Shaun Scheepers, Sulaiman Moosa. Department of Diagnostic Radiology, Stellenbosch University and Tygerberg Academic Hospital, Tygerberg, Western Cape. Braham van der Merwe, MB ChB , DA (SA).
Ladisa, John F; Olson, Lars E; Ropella, Kristina M; Molthen, Robert C; Haworth, Steven T; Kersten, Judy R; Warltier, David C; Pagel, Paul S
2005-08-01
Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been conducted at a resolution sufficient to detect subtle alterations in vascular geometry caused by the stent and the subsequent temporal development of NH. We present the details and limitations of a series of post-processing operations used in conjunction with microfocal X-ray CT imaging and reconstruction to generate geometrically accurate flow domains within the localized region of a stent several weeks after implantation. Microfocal X-ray CT reconstruction volumes were subjected to an automated program to perform arterial thresholding, spatial orientation, and surface smoothing of stented and unstented rabbit iliac arteries several weeks after antegrade implantation. A transfer function was obtained for the current post-processing methodology containing reconstructed 16 mm stents implanted into rabbit iliac arteries for up to 21 days after implantation and resolved at circumferential and axial resolutions of 32 and 50 microm, respectively. The results indicate that the techniques presented are sufficient to resolve distributions of WSS with 80% accuracy in segments containing 16 surface perturbations over a 16 mm stented region. These methods will be used to test the hypothesis that reductions in normalized wall shear stress (WSS) and increases in the spatial disparity of WSS immediately after stent implantation may spatially correlate with the temporal development of NH within the stented region.
Genous endothelial progenitor cell-capturing stent system: a novel stent technology
Klomp, Margo; Beijk, Marcel A. M.; de Winter, Robbert J.
2009-01-01
Drug-eluting stents have been demonstrated to significantly reduce clinical and angiographic restenosis in patients with coronary artery disease compared with bare-metal stents. Intuitively, however, a prohealing approach for the prevention of in-stent restenosis by promoting accelerated
Short vs prolonged dual antiplatelet treatment upon endovascular stenting of peripheral arteries
Directory of Open Access Journals (Sweden)
Kronlage M
2017-10-01
Full Text Available Mariya Kronlage,1 Maximilian Wassmann,1 Britta Vogel,1 Oliver J Müller,1 Erwin Blessing,2 Hugo Katus,1,3 Christian Erbel1 1Department of Cardiology, Angiology and Pneumology, University Hospital Heidelberg, Heidelberg, 2SRH Klinikum Karlsbad Langensteinbach, Karlsbad, 3DZHK German Center for Cardiovascular Research, Partner Site Heidelberg/Mannheim, Mannheim, Germany Introduction: Peripheral artery disease (PAD is a highly prevalent disorder with a substantial economical burden. Dual antiplatelet treatment (DAPT upon endovascular stenting to prevent acute thrombotic reocclusions is an universally accepted practice for postinterventional management of PAD patients. However, the optimal period of time for DAPT upon endovascular stenting is not known.Methods: In the current nonrandomized, retrospective monocentric study, we evaluated the duration of DAPT upon endovascular stenting. A total of 261 endovascular SFA and iliac stenting procedures were performed on 214 patients and these patients were subdivided into a short (4–6 weeks or a prolonged (8–12 weeks DAPT regime group. More than 65% of the patients included were male, approximately 35% were diabetic, and 61% had a history of smoking. Of all the patients, 90% exhibited a Rutherford stage 2–3, and approximately half of the patients had a moderate-to-severe calcified target lesion with a length of >13 cm. Major safety end points were defined as any bleeding, compartment syndrome, and ischemic events. In addition to this, patency, all-cause mortality, as well as amputation were followed up over a period of 12 months upon intervention.Results: Twelve months after endovascular stenting, primary patency in our cohort was comparable between the groups (83.94% short vs 79.8% long DAPT, P>0.05. Major bleeding occurred in 18 cases without any difference between the groups (P>0.05. In addition, during the 12-month follow-up, 6 (3.4% patients in the short and 3 (3.5% in the prolonged DAPT regime
[Changes of brain function and cognitive function after carotid artery stenting].
Lu, Z X; Deng, G; Wei, H L; Zhao, G F; Wen, L Z; Chen, X
2017-10-24
Objective: To investigate the effect of carotid artery stenting(CAS) on cognitive function and brain function based on changes of a battery of neuropsychological tests and magnetic resonance imaging. Methods: Thirty-three patients were included with 17 in the stent-placement group and 16 in the control group (receiving medical treatment), among whom, the unilateral or bilateral severe internal carotid artery stenosis was confirmed by cerebral vascular angiography in the department of Interventional Radiology and Vascular Surgery of Zhongda Hospital Southeast University from June 2015 to September 2016.Neuropsychological tests and rest-state blood oxygenation level dependent fMRI were performed at the baseline and six months follow-up.The baseline characteristics and follow-up changes were compared in each group. Results: The overall cognitive function of the stent-placement group was statistically significantly improved ( P function, memory, attention and other aspects.The value of amplitude of low-frequency fluctuation(ALFF) showed statistically significant increase ( P left prefrontal cortex ( t =5.861 3, P left superior parietal lobe( t =5.601 2, P left retrosplenial cingulate cortex( t =-5.590 4, P left insular cortex ( t =-6.340 8, P right insular cortex ( t =-8.129 9, P left dorsal anterior cingulate cortex ( t =-5.584 8, P 0.05, Alphasim correction)between baseline and follow-up results in control group.Besides, the ALFF changes of the left insular cortex ( r =-0.591, P =0.033) and bilateral motor cortical area ( r =-0.659, P =0.014) were negatively correlated with auditory verb learning test (AVLT) score changes.The ALFF change of bilateral motor cortical area was negatively correlated with the AVLT-delay score change ( r =-0.588, P =0.034). And the ALFF change on right insular cortex and the frontal assessment battery (FAB) score change was positively correlated ( r =0.638, P =0.025). Conclusions: The overall cognitive function of patients with carotid
Evaluation of the carotid and vertebral arteries: comparison of 3D SCTA and IA-DSA-work in progress
International Nuclear Information System (INIS)
Seemann, M.D.; Minx, C.; Heuck, A.; Reiser, M.F.; Englmeier, K.H.; Schuhmann, D.R.G.; Fuerst, H.
1999-01-01
Objective: The purpose of this study was to develop a method for three-dimensional (3D) visualization of the whole vascular system of the carotid and vertebral arteries using spiral computed tomographic angiography (SCTA), that allows accurate, qualitative and quantitative evaluation, of anatomical abnormalities, including detection of additional lesions, and estimation of degree of stenosis. Materials and methods: Fifteen patients with anatomical and pathological abnormalities of the arterial vascular system detected by color-coded duplex ultrasound were studied using intraarterial digital subtraction angiography (IA-DSA) with aortic arch injection, and SCTA. The carotid and vertebral arteries were segmented using an interactive threshold interval density volume-growing method and visualized with a color-coded shaded-surface display (SSD) rendering method. The adjacent bone structures were visualized using a transparent volume rendering method. Results: In all cases, the entire volume of the vascular system of the carotid and vertebral arteries could be visualized on SCTA, and the anatomical and pathological abnormalities on 3D SCTA correlated well with that seen on IA-DSA. Conclusion: Results of 3D SCTA had a high degree of correlation with results of IA-DSA in the evaluation of the vascular system of the carotid and vertebral arteries. The 3D SCTA with a subsecond spiral CT scanner is useful for the visualization of anatomical and pathological abnormalities in the circulation in the carotid and vertebral arteries and offer a promising minimally invasive alternative compared with other diagnostic procedures. (orig.) (orig.)
Endovascular stents: a review of their use in peripheral arterial disease.
Kudagi, Vinod S; White, Christopher J
2013-06-01
Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.
A suggested training programme for carotid artery stenting (CAS)
International Nuclear Information System (INIS)
Gaines, Peter; Nicholson, Tony
2006-01-01
Carotid artery stenting as an alternative to traditional carotid endartrectomy is becoming increasingly important in the treatment of transient ischemic attack and stroke. Physicians from several different medical disciplines are interested in treating appropriate patients by this method. Patients are entitled to know what training and experience the surgeon or clinician has before giving consent. This should involve endovascular experience in all systems and experience and knowledge of cerebral angiography and intervention. A multidisciplinary approach and reporting of adverse events is vital for patient safety
Clinical findings of intracranial vertebral artery disease using magnetic resonance angiography.
Liu, Lu-Han; Chen, Clayton Chi-Chang; Chang, Ming-Hong
2004-09-01
The vertebral artery lesion has a variety of clinical characteristics. We sought to clarify the clinical patterns and the location of the intracranial vertebral artery (ICVA) diseases according to analyses of images obtained using magnetic resonance angiography (MRA). We studied vascular lesions, risk factors, symptoms, signs, and outcomes in 35 patients with ICVA disease (3 had bilateral occlusion; 9, unilateral occlusion; 6, bilateral stenosis; and 17, unilateral stenosis). The most common site of unilateral and bilateral lesions was the distal ICVA after the origin of posterior inferior cerebellar artery (PICA). We found accompanying basilar artery disease in 28.6% of patients with unilateral and bilateral ICVA disease. The majority of the ICVA lesions were associated with internal carotid arteries disease (48.8%). The common vascular risk factors were hypertension (71%), diabetes mellitus (34%), hyperlipidemia (31%), smoking (29%), and coronary artery disease (23%). Eighteen patients (51.4%) had transient ischemic attacks (TIAs) only, 10 patients (28.6%) had TIAs before stroke, and 5 patients (14.3%) had strokes without TIAs. Most patients (80%) with TIAs, with or without stroke, had multiple episodes. Vertigo or dizziness, ataxia, limbs weakness and abnormal gait were the common symptoms and signs. At 6 months follow-up, 66.7% patients had no symptoms or only slight symptoms that caused no disability. Our data showed (1) the usual location of ICVA disease (occlusion or severe stenosis) was distal to PICA, especially near the vertebrobasilar junction; (2) the risk factors were hypertension, diabetes mellitus, hyperlipidemia, smoking, and coronary artery disease; (3) patients with ICVA disease had a high frequency of accompanying internal carotid, middle cerebral, or basilar artery disease; (4) vertigo or dizziness, and ataxia were the common symptoms and signs; (5) TIA was the most common clinical pattern; (6) the outcome was favorable, except in cases with
Maleux, G; Demaerel, P; Verbeken, E; Daenens, K; Heye, S; Van Sonhoven, F; Nevelsteen, A; Wilms, G
2006-10-01
Protected carotid artery stent placement is currently under clinical evaluation as a potential alternative to carotid endarterectomy. The current study was undertaken to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after protected carotid artery stent placement using a filter device and to determine the potential relationship between these new ischemic lesions and the presence or absence of a clear amount of debris captured by the neuroprotection filter device. A nonrandomized cohort of 52 patients (40 men, 12 women) presenting with carotid occlusive disease underwent protected carotid artery stent placement using a filter device. DWI obtained 1 day before stent placement was compared with that obtained 1 day after stent placement. In addition, the macroscopic and microscopic analysis of debris captured by the filter device during the carotid stent placement procedure was assessed. Neuroprotected carotid stent placement was technically successful in all 53 procedures but was complicated by a transient ischemic attack in 3 patients (5.6%). In 22 patients (41.5%), new ischemic lesions were found on DWI, and in 21 filter devices (39.6%), a substantial amount of atheromatous plaque and/or fibrin was found. No clear relationship between the presence of debris captured by the filter device and new lesions detected by DWI was found (P = .087; odds ratio 3.067). Neuroprotected carotid artery stent placement will not avoid silent cerebral ischemia. Systematic microscopic analysis of debris captured by the filter device has no predictive value for potential cerebral ischemia after carotid artery stent placement.
島田, 弘英; 大和, 眞史; 櫻井, 俊平; 疋田, 博之; 池田, 修一
2001-01-01
A coronary stent was deployed in the left anterior descending artery of an 82-year-old woman with unstable angina.Recurrence of subacute stent thrombosis and in-stent restenosis occurred frequently during the five months after initial stent implantation.Balloon angioplasty and cutting balloon angioplasty failed to prevent these complications,but they ceased after re-stenting in the initial stent.In this case,tissue protrusion through the stent strut, deformation of the coil stent and inadequa...
[Revascularization of the carotid and vertebral arteries in the elderly].
Illuminati, G; Bezzi, M; D'Urso, A; Giacobbi, D; Ceccanei, G; Vietri, F
2004-01-01
From January 1994 to July 2004, 323 patients underwent 348 revascularization of carotid bifurcation for atherosclerotic stenoses. Eighty eight patients (group A) were 75 year-old or older, whereas 235 (group B) were younger than 75 years. Postoperative mortality/neurologic morbidity rate was 1% in group A, and 1.4% in group B. At 5 years, patency and freedom from symptoms/stroke were, respectively, 91% and 92% in group A, and 89% and 91% in group B. None of these differences was statistically significant. In the same time period, 26 internal carotid arteries were revascularized in 24 patients, 75 or more aged, for a symptomatic kinking. Postoperative mortality/morbidity rate was absent, whereas, at 5 years, patency and freedom from symptoms/stroke were, respectively, 88% and 92%. Twelve vertebral arteries were revascularized in 12 patients, 75 or more aged, for invalidating symptoms of vertebrobasilar insufficiency. Postoperative mortality/neurologic morbidity rate was absent. In one case postoperative recurrence of symptoms occurred, despite a patent revascularization. Patency and freedom from symptoms/stroke were 84% and 75%, at 5 years. Revascularization of carotid and vertebral arteries in the elderly can be accomplished with good results, superposable to those of standard revascularization of carotid bifurcation in a younger patients' population.
Directory of Open Access Journals (Sweden)
Xiang-yu CAO
2016-12-01
Full Text Available Objective To explore the clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting to predict the reflux of perforator veins after operation. Methods A total of 93 patients (including 51 with cerebral venous sinus stenosis and intracranial hypertension and 42 with intractable pulsatile tinnitus caused by cerebral venous sinus stenosis who were treated by stent implantation were analyzed retrospectively. Among those patients, the diameter of transverse and sigmoid sinuses of 63 cases were measured based on angiography, and stent was selected according to the measurement result. The other 30 cases were given angiography on ipsilateral carotid artery or vertebral artery when the balloon was dilated in the venous sinus to confirm the reflux of perforator veins. If the venous reflux decreased in the angiography, stent with diameter 1-2 mm less than that of venous sinus could be selected. Results The success rate of stenting was 100% (93/93. In 63 cases, 45 cases were planted 9 mm × 40 mm stents, 15 were planted 8 mm × 40 mm stents, 3 were planted 7 mm × 40 mm stents. The average diameter of stents was (8.67 ± 0.68 mm. There were 11 cases (17.46% with slow perforator venous reflux after operation. In the other 30 cases, 3 cases were planted 8 mm × 40 mm stents, 11 were planted 7 mm × 40 mm stents, and 16 were planted 6 mm × 40 mm stents. The average diameter of stents was (7.57 ± 0.67 mm. There was only one case (3.33% with slow perforator venous reflux after operation. The difference of stent diameter between 2 groups was statistically significant (t = 15.632, P = 0.001. The occurrence rate of perforator vein occlusion after operation between 2 groups was significantly different (adjusted χ 2 = 60.065, P = 0.001. Conclusions Perforator vein occlusion after cerebral venous sinus stenting is common complication. Balloon dilatation angiography could predict the possibility of perforator vein
Thakar, Tejal; Chaudhuri, Arindam
2013-06-01
To present a preliminary experience using a multilayer flow-modulating stent for trans/infragenicular popliteal endovascular aneurysm repair. Five men (mean age 76 years, range 62-86) with 6 popliteal artery aneurysms (PAAs) measuring 22 to 39 mm in diameter (mean 30) underwent endovascular repair using the Cardiatis Multilayer Aneurysm Repair System (MARS) between June and August 2011. Radiological assessments post procedure using duplex ultrasonography and biplanar knee radiographs (additional contrast studies as necessary) sought evidence of aneurysm exclusion, graft patency, and preservation of branches and runoff vessels. Technical success was achieved in each case. There was one symptomatic stent occlusion requiring thrombectomy at 4 days, with reocclusion, and one leak via the stent struts into the sac with no branch outflow identified. Two further symptomatic stent occlusions were identified within a 6-week follow-up period, totaling 3 occlusions among the 6 devices deployed. No firm conclusion can be reached on the efficacy of the MARS in PAAs due to the inherent limitations of this small series, although a 50% thrombosis rate is a poor outcome. The risk of early thrombosis in flow-modulating stents deployed in the popliteal artery exists, as it does with earlier generation stent-grafts. Larger prospective trials and the influence of more aggressive antithrombotic/anticoagulant therapy should be considered to enable accurate evaluation of this device in popliteal artery aneurysms.
Pseudoaneurysm of the Internal Carotid Artery: Treatment with a Covered Stent
International Nuclear Information System (INIS)
Scavee, Vincent; Wispelaere, Jean-Francois de; Mormont, Eric; Coulier, Bruno; Trigaux, Jean-Paul; Schoevaerdts, Jean-Claude
2001-01-01
Dissection of the cervical segment of the internal carotid artery may occur spontaneously or after trauma. We report the management of a 53-year-old right-handed man with progressive dizziness and neck pain 6 weeks after a motor vehicle collision. The clinical and neurologic examinations were normal. The CT scan led to the diagnosis of a pseudoaneurysm of the right internal carotid artery near the skull base. We successfully treated this post-traumatic lesion with a covered stent. The patient underwent the endovascular procedure under general anesthesia and transcranial Doppler monitoring. No neurologic event was observed. Obliteration of the pseudoaneurysm with preservation of the carotid artery was achieved. The patient was discharged from the hospital 72 hr later with no complications. Clinical and imaging follow-up at 6 months was unremarkable
Energy Technology Data Exchange (ETDEWEB)
Kalmar, Peter I., E-mail: peter.kalmar@medunigraz.at; Portugaller, Rupert H., E-mail: rupert.portugaller@medunigraz.at; Schedlbauer, Peter, E-mail: peter.schedlbauer@klinikum-graz.at; Bohlsen, Dennis, E-mail: dennis.bohlsen@medunigraz.at; Deutschmann, Hannes A., E-mail: hannes.deutschmann@medunigraz.at
2014-07-15
Purpose: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. Materials and methods: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. Results: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mmHg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p = 0.328). Conclusions: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents.
International Nuclear Information System (INIS)
Kalmar, Peter I.; Portugaller, Rupert H.; Schedlbauer, Peter; Bohlsen, Dennis; Deutschmann, Hannes A.
2014-01-01
Purpose: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. Materials and methods: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. Results: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mmHg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p = 0.328). Conclusions: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents
The impact of renal artery stent revascularization on blood pressure: 1-year follow-up of 110 cases
International Nuclear Information System (INIS)
Wang Chao; Zou Yinghua; Yang Min; Wang Jian; Tong Xiaoqiang; Song Li
2007-01-01
Objective: To investigate the effect of renal artery revascularization through renal artery stenting(PTRAS)on blood pressure in patients with renal artery stenosis. Methods: During April 2000 through May 2005 110 cases of renal artery stenosis received PTRAS and followed up for at least 1 year with blood pressure measurements pre-and 1 year post-PTRAS. Results: The technical success rate was 100% for all 110 cases. The renal artery stenosis were decreased from 60%-100% before PTRAS to 0%-15% after the stent placement. There was significant difference between blood pressure pre-and 1 year post PTRAS. Systolic pressures decreased from(153 ± 32) mmHg to(131 ± 27) mmHg and diastolic pressures from(87 ± 19) mmHg to(75 ± 19) mmHg. The administration of antihypertensive diugs reduced from(2.6 ± 0.9 ) sorts to(1.9 ± 0.9) sorts. Conclusions: PTRAS revascularization is an effective procedure for blood pressure control in renal vascular hypertension during one year follow up. (authors)
Comparison of coronary-artery bypass surgery and stenting for the treatment of multivessel disease
L.A. van Herwerden (Lex); B.A. van Hout (Ben); M-A.M. Morel (Marie-Angèle); F. Unger (Felix); J.E. Sousa (Eduardo); A. Jatene (Adib); J.J.R.M. Bonnier (Hans); J.P.A.M. Schonberger (Jacques); N. Buller (Nigel); R. Bonser (Robert); M.J.B.M. van den Brand (Marcel); P.W.J.C. Serruys (Patrick)
2001-01-01
textabstractBACKGROUND: The recent recognition that coronary-artery stenting has improved the short- and long-term outcomes of patients treated with angioplasty has made it necessary to reevaluate the relative benefits of bypass surgery and percutaneous interventions in patients with multivessel
International Nuclear Information System (INIS)
Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan
2011-01-01
Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.
Energy Technology Data Exchange (ETDEWEB)
Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)
2011-12-15
Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.
Polyakov, V Ya; Nikolaev, Yu A; Pegova, S V; Matsievskaya, T R; Obukhov, I V
2016-01-01
The study included 1172 patients (410 men and 762 women) at the mean age of 60.3 ± 10.4 years with grade I-II (stage I-II) arterial hypertension (AH) admitted to the clinic of Institute of Experimental Medicine. The patients were divided into 2 groups based on the results of clinical and laboratory diagnostics. Group 1 (n = 525) included patients with AH and hepatobiliary system (HBS) diseases, group 2 (n = 647) patients with AH without HBS diseases. The patients group 1 had a thicker intima-media complex of carotid arteries, higher peak systolic bloodflow rate in the internal and vertebral carotid arteries, more pronounced coiling of internal carotid arteries than patients of group 2. Patients with AH and HBS diseases exhibited correlation between bloodflow rate in external carotid arteries and atherogenicity coefficient. Duplex scanning of neck vessels of in patients with AH without HBS diseases revealed peculiar changes of the intima-media thickness and hemodynamically significant changes of the blood flow in the internal carotid arteries that may be of prognostic value in this nosological syntropy and require the personified approach to diagnostics, treatment, and prevention of these conditions.
Directory of Open Access Journals (Sweden)
Zhi-hua DU
2011-09-01
Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.
Taher, Fadi; Bokums, Kristaps; Aichmair, Alexander; Hughes, Alexander P
2014-05-01
An exact understanding of patient vertebral artery anatomy is essential to safely place screws at the atlanto-axial level in posterior arthrodesis. We aim to report a case of erosion of the left vertebral artery into the C1-C2 facet complex with resultant rotatory and lateral listhesis presenting with severe occipital headache. This represents a novel etiology for this diagnosis and our report illustrates technical considerations when instrumenting the C1-C2 segment. We report a case of severe occipital headache due to C1-C2 instability with resultant left C2 nerve compression in the setting of erosion of the vertebral artery into the C1-C2 facet complex. A 68-year-old woman presented with a 12-month history of progressively debilitating headache and neck pain with atlanto-axial instability. Computed tomography (CT) angiography demonstrated erosion of the left vertebral artery into the left C1-C2 facet complex. In addition, the tortuous vertebral arteries had eroded into the C2 pedicles, eliminating the possibility for posterior pedicle screw placement. The patient underwent posterior arthrodesis of C1-C2 utilizing bilateral lateral mass fixation into C1 and bilateral trans-laminar fixation into C2 with resolution of all preoperative complaints. This study constitutes the first report of a tortuous vertebral artery causing the partial destruction of a C1-C2 facet complex, as well as instability, with the clinical presentation of severe occipital headache. It hereby presents a novel etiology for both the development of C1-C2 segment instability as well as the development of occipital headache. Careful evaluation of such lesions utilizing CT angiography is important when formulating a surgical plan.
Energy Technology Data Exchange (ETDEWEB)
Yoon, Woong; Seo, Jeong Jin [Chonnam National University Medical School, Department of Radiology, Chonnam National University Hospital, 501-757Dong-gu, Gwangju (Korea); Kim, Tae Sun [Chonnam National University Medical School, Department of Neurosurgery, Chonnam National University Hospital, Dong-gu, Gwangju (Korea); Do, Huy M.; Jayaraman, Mahesh V.; Marks, Michael P. [Stanford University Medical Center, Department of Radiology, Stanford, California (United States)
2007-04-15
Intracranial vertebral artery (VA) dissection has three clinical presentations: ischemia, hemorrhage, and mass effect. Imaging findings of intracranial VA dissections vary according to clinical presentation. Irregular stenosis or occlusion of the VA is the most common finding in patients with posterior fossa infarction, whereas a dissecting aneurysm is the main feature in those with acute subarachnoid hemorrhage. A chronic, giant, dissecting aneurysm can cause mass effect on the brain stem or cranial nerves, as well as distal embolism. Magnetic resonance imaging is useful for detection of intramural hematomas and intimal flaps, both of which are diagnostic of VA dissection. Multidetector computed tomography angiography is increasingly used for diagnosis of VA dissection. Catheter angiography is still beneficial for evaluation of precise endoluminal morphology of the dissection before surgical or endovascular intervention. Endovascular treatment is now considered a major therapeutic option for patients with a ruptured dissecting aneurysm or a chronic dissecting aneurysm. Anticoagulation therapy is currently considered the initial treatment of choice in patients with posterior circulation ischemic symptoms. Endovascular treatment, such as stent-assisted angioplasty or coil occlusion at the dissection site, can be performed in selected patients with posterior fossa ischemic symptoms. (orig.)
International Nuclear Information System (INIS)
Yoon, Woong; Seo, Jeong Jin; Kim, Tae Sun; Do, Huy M.; Jayaraman, Mahesh V.; Marks, Michael P.
2007-01-01
Intracranial vertebral artery (VA) dissection has three clinical presentations: ischemia, hemorrhage, and mass effect. Imaging findings of intracranial VA dissections vary according to clinical presentation. Irregular stenosis or occlusion of the VA is the most common finding in patients with posterior fossa infarction, whereas a dissecting aneurysm is the main feature in those with acute subarachnoid hemorrhage. A chronic, giant, dissecting aneurysm can cause mass effect on the brain stem or cranial nerves, as well as distal embolism. Magnetic resonance imaging is useful for detection of intramural hematomas and intimal flaps, both of which are diagnostic of VA dissection. Multidetector computed tomography angiography is increasingly used for diagnosis of VA dissection. Catheter angiography is still beneficial for evaluation of precise endoluminal morphology of the dissection before surgical or endovascular intervention. Endovascular treatment is now considered a major therapeutic option for patients with a ruptured dissecting aneurysm or a chronic dissecting aneurysm. Anticoagulation therapy is currently considered the initial treatment of choice in patients with posterior circulation ischemic symptoms. Endovascular treatment, such as stent-assisted angioplasty or coil occlusion at the dissection site, can be performed in selected patients with posterior fossa ischemic symptoms. (orig.)
International Nuclear Information System (INIS)
Rabellino, Martin; Garcia Nielsen, L.; Baldi, S.; Zander, T.; Arnaiz, L.; Llorens, R.; Zerolo, I.; Maynar, M.
2009-01-01
Endoleak is a frequent complication after endovascular repair of aortic rupture. We describe the case of a female patient with traumatic aortic injury, treated with endograft, who developed a type II endoleak through the left subclavian and vertebral arteries. Both arteries originated independently from the aortic arch, and were managed with coil embolization of each vessel. We also report our experience with treating the left vertebral artery by placing a microcatheter through the right vertebral one.
International Nuclear Information System (INIS)
Tsetis, D.
2012-01-01
Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future
Energy Technology Data Exchange (ETDEWEB)
Rangi, P.S.; Clifton, A. [St Georges Hospital, Department of Neuroradiology, Atkinson Morley Wing, Tooting, London (United Kingdom); Markus, H.S.; Punter, M.N.M. [St Georges University of London, Centre for Clinical Neuroscience, Cranmer Terrace, London (United Kingdom)
2007-03-15
Carotid artery stenting is a recently introduced treatment in symptomatic atherosclerotic carotid artery disease with acceptable complication rates. The major risk is perioperative embolic stroke. Transcranial Doppler ultrasonography (TCD) can be used to identify embolic signals and guide therapy. We present a case of symptomatic embolization in a 72-year-old female following carotid stent deployment complicated by haemodynamic changes. Despite concurrent dual antiplatelet medication significant symptomatic embolization occurred even after restoration of the blood pressure, and modulation of the rate of embolization was achieved using dextran-40 guided by TCD monitoring. The patient recovered from an initially profound hemiparesis and dysphasia to minor sensory changes. Microemboli are common following carotid artery stenting and there appears to be a threshold phenomenon associated with prolonged embolization and progression to cerebral infarction. TCD can be used to detect particulate microemboli and therefore may be useful in guiding antithrombotic therapy in this setting. Dextran-40 has been shown to reduce the embolic load following carotid endarterectomy and was used to good effect in this patient in terms of both embolic load and clinical outcome. This is the first case of embolization following carotid stenting successfully treated with dextran-40, and offers a further option for therapeutic intervention in microembolism detected by TCD and stresses the importance of perioperative monitoring of embolic load for postoperative stroke risk. (orig.)
Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H
2018-04-19
Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
International Nuclear Information System (INIS)
Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Pieniazek, Piotr; Musialek, Piotr; Kozanecki, Artur; Stopa, Ireneusz; Zalewski, Jaroslaw; Tracz, Wieslawa
2007-01-01
Purpose. Subclavian or innominate artery (SIA) stenosis affects up to 5% of patients referred to coronary bypass grafting; it is symptomatic in less than half of these. This study aimed to assess the Doppler ultrasonography (DU) findings in SIA obstruction and patients' follow-up after percutaneous angioplasty (PTA). Methods. The study enrolled 118 patients (68 men, 50 women), aged 61.3 ± 8.7 years, with suspected SIA obstruction, in whom peak systolic velocity (PSV) in the SIA and subclavian steal grade were assessed on DU and verified by quantitative angiography (QA). Serial follow-up DU was performed in patients treated with PTA. Results. Grade I-III of subclavian steal from the vertebral artery (VA) was found in 89.8% of patients. In the remaining 10.2% only a PSV increase in the SIA was observed. QA confirmed the presence of SIA obstruction in all patients (stenosis grade: 80.9 ± 17.3%). In patients with one-sided SIA obstruction, the ultrasonographic steal grade correlated with the QA stenosis grade (p < 0.001, r = 0.648). Lack of subclavian steal was noted in the case of distal subclavian stenosis, VA obstruction, VA originating from the aortic arch, and bilateral SIA obstruction. Successful PTA was performed in 77 of 83 patients referred to that procedure. PSV was reduced from 4.4 ± 1.2 (2.2-6.5) m/sec to 1.34 ± 0.51 (0.5-2.5) m/sec and flow in the VA was normalized. During the mean follow-up time of 24.7 ± 15.6 months, there was a gradual increase in the in-stent PSV as well as gradual VA flow alterations, resulting in symptom recurrence. More than a twofold PSV increase, compared with the post-PTA values, was an indicator of restenosis in 11 of 12 patients. Conclusions. Careful DU evaluation enables the recognition of SIA obstruction in all patients. Ninety percent of them have subclavian steal correlating with the stenosis grade. Restenosis can be reliably detected with DU based on in-stent PSV and VA flow alterations
Asymptotic analysis of blood flow in stented arteries: time dependency and direct simulations***
Directory of Open Access Journals (Sweden)
Pichon Gostaf Kirill
2010-12-01
Full Text Available This work aims to extend in two distinct directions results recently obtained in [10]. In a first step we focus on the possible extension of our results to the time dependent case. Whereas in the second part some preliminary numerical simulations aim to give orders of magnitudes in terms of numerical costs of direct 3D simulations. We consider, in the first part, the time dependent rough problem for a simplified heat equation in a straight channel that mimics the axial velocity under an oscillating pressure gradient. We derive first order approximations with respect to ϵ, the size of the roughness. In order to understand the problem and set up correct boundary layer approximations, we perform a time periodic fourier analysis and check that no frequency can interact with the roughness. We show rigorously on this toy problem that the boundary layers remain stationary in time (independent on the frequency number. Finally we perform numerical tests validating our theoretical approach. In the second part, we determine actual limits, when running three-dimensional blood flow simulations of the non-homogenized stented arteries. We solve the stationary Stokes equations for an artery containing a saccular aneurysm. Consecutive levels of uniform mesh refinement, serve to relate spatial resolution, problem scale, and required computation time. Test computations are presented for femoral side aneurysm, where a simplified ten-wire stent model was placed across the aneurysm throat. We advocate the proposed stent homogenization model, by concluding that an actual computation power is not sufficient to run accurate, direct simulations of a pulsatile flow in stented vessels.
Safety of Early Carotid Artery Stenting after Systemic Thrombolysis: A Single Center Experience
Directory of Open Access Journals (Sweden)
Fabrizio Sallustio
2012-01-01
Full Text Available Background. Patients with acute ischemic stroke due to internal carotid artery (ICA disease are at high risk of early stroke recurrence. A combination of IV thrombolysis and early carotid artery stenting (CAS may result in more effective secondary stroke prevention. Objective. We tested safety and durability of early CAS following IV thrombolysis in stroke patients with residual stenosis in the symptomatic ICA. Methods. Of consecutive patients treated with IV rtPA, those with residual ICA stenosis ≥70% or 24 hours. The protocol included pre-rtPA MRI and MR angiography, and post-rtPA carotid ultrasound and CT angiography. Stroke severity was assessed by the NIH Stroke Scale (NIHSS. Three- and twelve-month stent patency was assessed by ultrasound. Twelve-month functional outcome was assessed by the modified Rankin Scale (mRS. Results. Of 145 consecutive IV rtPA-treated patients, 6 (4% underwent early CAS. Median age was 76 (range 67–78 years, median NIHSS at stroke onset was 12 (range 9–16 and 7 (range 7-8 before CAS. Median onset-to-CAS time was 48 (range 30–94 hours. A single self-expandable stent was implanted to cover the entire lesion in all patients. The procedure was uneventful in all patients. After 12 months, all patients had stent patency, and the functional outcome was favourable (mRS ≤ 2 in all but 1 patient experiencing a recurrent stroke for new-onset atrial fibrillation. Conclusion. This small case series of a single centre suggests that early CAS may be considered a safe alternative to CEA after IV rtPA administration in selected patients at high risk of stroke recurrence.
Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W
2010-07-01
To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.
Stenting of the Superior Mesenteric Artery as a Preoperative Treatment for Total Pancreatectomy
International Nuclear Information System (INIS)
Tanigawa, Noboru; Kariya, Shuji; Komemushi, Atsushi; Satoi, Sohei; Kamiyama, Yasuo; Sawada, Satoshi; Kojima, Hiroyuki; Sougawa, Mitsuharu; Takai, Yuichirou
2004-01-01
The patient was a 58-year-old male with mucinous cyst adenocarcinoma of the pancreas. Prior to total pancreatectomy, preoperative CT and angiography showed a high-grade arteriosclerotic stenosis of about 1.0 cm in length in the ostium of the superior mesenteric artery (SMA), as well as the development of collateral vessels in the area around the head of the pancreas. A stent was placed in the SMA stenosis to preserve the intestinal blood flow in the SMA region after total pancreatectomy, which was performed 25 days after stent placement. The postoperative SMA blood flow was favorable, with no postoperative intestinal ischemia, and the patient had an uneventful postoperative course
Itami, Hisakazu; Tokunaga, Koji; Okuma, Yu; Hishikawa, Tomohito; Sugiu, Kenji; Ida, Kentaro; Date, Isao
2013-09-01
Although self-expanding carotid stents may dilate gradually, the degrees of residual stenosis have been quantified by the NASCET criteria, which is too simple to reflect the configuration of the stented artery. We measured the volumes of the stent lumens chronologically by 3D-CT in patients after carotid artery stenting (CAS), and analyzed the correlations between the volume change and medical factors. Fourteen patients with carotid artery stenosis were treated using self-expanding, open-cell stents. All patients underwent preoperative plaque MRI (magnetization-prepared rapid acquisition gradient-echo, MPRAGE) and chronological 3D-CT examinations of their stents immediately after their placement and 1 day, 1 week, and 1 month after the procedure. The volume of the stent lumen was measured using a 3D workstation. The correlations between stent volume and various factors including the presence of underlying diseases, plaque characteristics, and the results of the CAS procedure were analyzed. Stent volume gradually increased in each case and had increased by 1.04-1.55 (mean, 1.25)-fold at 1 postoperative month. The presence of underlying medical diseases, plaque length, the degree of residual stenosis immediately after CAS, and plaque calcification did not have an impact on the change in stent volume. On the other hand, the stent volume increase was significantly larger in the patients with vulnerable plaques that demonstrated high MPRAGE signal intensity (P stent volume. Self-expanding stents in carotid arteries containing vulnerable plaques expand significantly more than those without such plaques in a follow-up period.
Müller-Hülsbeck, Stefan; Frahm, Christian; Behm, Charlotte; Schäfer, Phillip Jobst; Bolte, Hendrik; Heller, Martin; Jahnke, Thomas
2005-07-01
To determine feasibility, safety, and midterm patency of a monorail balloon stent device for the treatment of renal artery stenosis (RAS). During a period of 30 months, 47 patients (with severe hypertension, n=45; renal insufficiency, n=20) with 50 cases of RAS and indications for stent implantation (calcified ostial lesion, n=41; insufficient percutaneous transluminal angioplasty, n=6; dissection, n=3) were enrolled into the prospective evaluation. After predilation, 59 stents (Rx-Herculink 4 mm, n=2; 5 mm, n=19; 6 mm, n=35; 7 mm, n=3) were implanted under manometer control with use of the long-sheath technique (5 F; 6 F for 7-mm stents) via a femoral (n=44) or transbrachial approach (n=6). Parameters of hypertension and renal insufficiency were determined before and after the procedure and for a maximum of 18 months. Restenosis rate was determined with color duplex ultrasonography. Renal artery stent placement (mean diameter, 5.7 mm; mean length, 16 mm) was technically successful in all cases (100%). Mean blood pressure and serum creatinine level decreased from 177/93 mm Hg to 145/78 mm Hg and from 1.8 mg/dL to 1.5 mg/dL, respectively. Within 48 hours after the implantation, acute occlusions occurred in two patients, supposedly triggered by cholesterol embolization. Primary and primary assisted patency rates were 87% and 92% at 6 months and 75% and 84% at 18 months. Renal artery stent placement with the rapid-exchange monorail system is a safe procedure with promising patency rates. In combination with the long-sheath technique, adequate control of stent deployment is guaranteed during the entire intervention. The low profile of the device facilitates the use of small sheaths (5 F) to minimize access-site complications.
[Absorbable coronary stents. New promising technology].
Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan
2007-06-01
Coronary stent implantation started in Germany 20 years ago. In the beginning, the progress was very slow and accelerated 10 years later. Meanwhile, coronary stent implantation is a standard procedure in interventional cardiology. From the beginning of permanent stent implantation, research started to provide temporary stenting of coronary arteries, first with catheter-based systems, later with stent-alone technology. Stents were produced from polymers or metal. The first polymer stent implantation failed except the Igaki-Tamai stent in Japan. Newly developed absorbable polymer stents seem to be very promising, as intravascular ultrasound (IVUS) and optical coherence tomography have demonstrated. Temporary metal stents were developed based on iron and magnesium. Currently, the iron stent is tested in peripheral arteries. The absorbable magnesium stent (Biotronik, Berlin, Germany) was tested in peripheral arteries below the knee and meanwhile in the multicenter international PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) study. The first magnesium stent implantation was performed on July 30, 2004 after extended experimental testing in Essen. The magnesium stent behaved like a bare-metal stent with low recoil of 5-7%. The stent struts were absorbed when tested with IVUS. Stent struts were not visible by fluoroscopy or computed tomography (CT) as well as magnetic resonance imaging (MRI). That means, that the magnesium stent is invisible and therefore CT and MRI can be used for imaging of interventions. Only using micro-CT the stent struts were visible. The absorption process could be demonstrated in a patient 18 days after implantation due to suspected acute coronary syndrome, which was excluded. IVUS showed a nice open lumen. Stent struts were no longer visible, but replaced by tissue indicating the previous stent location. Coronary angiography after 4 months showed an ischemia-driven target lesion
Mpotsaris, Anastasios; Kabbasch, Christoph; Borggrefe, Jan; Gontu, Vamsi; Soderman, Michael
2017-04-01
Background Emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy is a routine procedure. Yet, precise indications and clinical safety in this setting remains controversial. Present data for mechanical thrombectomy include few studies with acute stenting of tandem occlusions. We evaluated the feasibility, safety and clinical outcome of this endovascular treatment in a retrospective analysis of all consecutive cases at a comprehensive stroke centre. Methods This was a retrospective analysis of all consecutive patients with acute extracranial carotid artery occlusion including acute dissection or high-grade stenosis and concomitant intracranial large-vessel occlusion treated with emergency carotid stenting and intracranial mechanical thrombectomy between November 2007 and May 2015. Results A total of 63 patients with a median age of 67 years (range 33-84 years) were treated. Of these, 33 (52%) patients had concomitant intravenous thrombolysis with recombinant tissue-type plasminogen activator initially. Median admission National Institutes of Health Stroke Scale was 14 (range 1-29). Median time from stroke onset to recanalization was 408 minutes (range 165-1846 minutes). Procedure time was significantly shorter after intravenous thrombolysis (110 minutes [range 15-202 minutes] vs. 130 minutes [range 60-280 minutes]; p = 0.02). Three (5%) patients experienced post-procedural symptomatic intracerebral haemorrhage. In 55/63 (87%) patients, a score of ≥2b on the Thrombolysis in Cerebral Infarction scale could be achieved. Eight (13%) patients died, five (8%) during the acute phase. A total of 29/63 (46%) patients showed a favourable outcome (modified Rankin Scale score of 0-2) after three months. Conclusions Our single-centre retrospective analysis of emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy demonstrated high
Stents in Renal Artery Bifurcation Stenosis: A Case Report
Directory of Open Access Journals (Sweden)
Polytimi Leonardou
2011-01-01
Full Text Available A 39-year-old patient presented with poorly controlled hypertension, and she was referred to renal angiogram and potential renal angioplasty. Renal angiogram showed a bifurcation lesion of the right renal artery. A guide wire was used to cross the upper branch, while the lower branch was protected by another same-type guide wire through the same introducer. Two thin monorail balloons were used to dilate the two branches; however, despite balloon dilatation, the stenosis of the vessels persisted. The “kissing balloon” technique was then attempted by simultaneously inflating both branches using the same balloons, but more than a 70% residual stenosis persisted in each branch. Two stents were finally placed in a “kissing” way through the main renal artery. The imaging and clinical results were good, without any procedure-related complications. Three years clinical followup was also good, without any reason for further interventional approach.
Stents in Renal Artery Bifurcation Stenosis: A Case Report
Leonardou, Polytimi; Pappas, Paris
2011-01-01
A 39-year-old patient presented with poorly controlled hypertension, and she was referred to renal angiogram and potential renal angioplasty. Renal angiogram showed a bifurcation lesion of the right renal artery. A guide wire was used to cross the upper branch, while the lower branch was protected by another same-type guide wire through the same introducer. Two thin monorail balloons were used to dilate the two branches; however, despite balloon dilatation, the stenosis of the vessels persisted. The “kissing balloon” technique was then attempted by simultaneously inflating both branches using the same balloons, but more than a 70% residual stenosis persisted in each branch. Two stents were finally placed in a “kissing” way through the main renal artery. The imaging and clinical results were good, without any procedure-related complications. Three years clinical followup was also good, without any reason for further interventional approach. PMID:21789043
LENUS (Irish Health Repository)
Sultan, Sherif
2002-01-01
The most prevalent lesion of the vertebral artery is an atheromatous plaque located at its origin from the subclavian artery. A case of successful management of a symptomatic vertebral artery aneurysm due to Ehlers-Danlos syndrome is reported. The patient had asymptomatic posterior intracerebral artery dissection on the contralateral side. A common carotid artery to V-3 segment bypass using reversed saphenous vein graft was carried out. Avulsion of the V-2 segment occurred peroperatively and endovascular coil embolization of the vertebral artery aneurysm was performed. Endovascular equipment and training must be in the armamentarium of vascular surgeons as more complex cases are being treated, which demands new approaches for ultimate clinical success. This unique case outlines what might unexpectedly occur. Endovascular intervention as an adjuvant procedure provides a satisfactory outcome in what could have been a catastrophe.
International Nuclear Information System (INIS)
Bakker, Jeannette; Goffette, Pierre P.; Henry, Michel; Mali, Willem P.T.M.; Melki, Jean-Pierre; Moss, Jon G.; Rabbia, Claudio; Therasse, Eric; Thomson, Kenneth R.; Thurnher, Siegfried; Vignali, Claudio
1999-01-01
Purpose: To assess, in a multicenter setting, safety, technical results, and restenosis rate of the Palmaz stent for treatment of atherosclerotic ostial renal artery stenosis. Methods: Ten centers enrolled 106 patients (120 treated renal artery stenoses) in the study. Patient selection was based on unsuccessful percutaneous transluminal renal angioplasty (residual stenosis ≥ 20%) performed for treatment of ostial stenosis ≥ 50%, in patients with hypertension and/or impaired renal function. Safety was assessed by means of the complication rate, and technical results by the number of successful stent placements and occurrence of restenosis (>50%) at intraarterial angiographic follow-up. Results: Stent placement was successful (n = 112) or partially successful (n = 5) in 117 (98%) arteries. Complications occurred in 19 procedures; seven were of serious clinical significance. Angiographic follow-up was performed in 89 of 117 (76%) cases, at a mean of 8 months (range 2.5-18 months). Fifteen stents (16.9%) showed restenosis (at a mean of 8.5 months), of which 10 were successfully redilated. Conclusion: Renal artery stenting has a high technical success rate, a complication rate comparable to percutaneous transluminal renal angioplasty, and a low rate of restenosis at 8 months angiographic follow-up
Energy Technology Data Exchange (ETDEWEB)
Lee, Ji Hoon; Kim, Dong Hun; Kim, Dong Hyun; Seo, Hong Joo [Chosun University College of Medicine, Gwangju (Korea, Republic of)
2014-04-15
We report a case of a massive hemothorax arising from a ruptured vertebral artery aneurysm in a patient with neurofibromatosis type 1 suffering from sudden onset of dyspnea. The vertebral artery aneurysm was treated with endovascular coil embolization. Then, an open thoracotomy was performed to evacuate the hematoma.
Energy Technology Data Exchange (ETDEWEB)
Chang, Il Soo; Chee, Hyun Keun; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong Hwan; Jung, Hong Geun [Konkuk University Hospital, Seoul (Korea, Republic of)
2011-04-15
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint
Safety of Carotid Artery Stenting in Elderly Patients with Severe Carotid Artery Stenosis
International Nuclear Information System (INIS)
Choi, Seul Kee; Kim, Seul Kee; Jeong, Min Young; Yoon, Woong
2012-01-01
To determine the safety of carotid artery stenting (CAS) using an emboli-protection device in elderly patients with severe carotid artery stenosis. Ninety consecutive patients who were at high risk for carotid endarterectomy underwent protected CAS using an emboli-protection device. Patients were divided into two groups by age: < 70 and ≥ 70. The primary outcome measure was the combined incidence of stroke, myocardial infarction (MI), and death within 30 days of CAS. The secondary outcome measures were technical success and hyperperfusion syndrome. Associations between age and the clinical outcomes were investigated. Overall, 30-day stroke, MI, and death rates were 6.7%. There was no significant difference in the primary outcome between the older age group (n = 56) and younger age group (n = 34) (8.9% and 2.9%, respectively; HR for age ≥ 70, 1.141; 95% CI, 0.875 to 1.488, p = 0.331). A logistic regression showed there was no independent variable associated with primary outcome. Technical success was achieved in all patients and there was no significant difference in the incidence of hyperperfusion syndrome between the two age groups. The results of this study suggest that protected CAS seems to be safe in elderly patients with severe carotid artery stenosis.
Vertebral and carotid artery anomalies in patients with aberrant right subclavian arteries
International Nuclear Information System (INIS)
Tsai, I.C.; Lee, Tain; Tzeng, Wen-Sheng; Jan, Sheng-Lin; Fu, Yun-Ching; Chen, Min-Chi; Lin, Pao-Chun; Liao, Wan-Chun; Chen, C.C.C.
2007-01-01
There is little published evidence regarding the patterns and prevalence of vertebral artery (VA) and common carotid artery (CCA) anomalies in patients with an aberrant right subclavian artery (ARSCA). To study the patterns and prevalence of VA and CCA anomalies in patients with ARSCA. In a 2-year period we reviewed the children referred with suspected vascular ring who had undergone multidetector-row CT. Patients with ARSCA were reviewed for VA and CCA patterns and their prevalence and relevance were calculated. In total, 102 patients with ARSCA were identified. VA anomalies were present in 16 patients (15.7%), and CCA anomalies (common carotid trunk) in 21 patients (20.6%). In some patients with VA anomalies, the right VA arose from the right CCA and in some the left VA arose from the aortic arch. When the left VA arose from the aortic arch it was situated between the left CCA and the left SCA or between the left SCA and the ARSCA. If neurointerventionalists understand these potential anomalies and their prevalence, time and contrast medium could be saved when catheterizing the VA and CCA in patients with ARSCA. (orig.)
International Nuclear Information System (INIS)
Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech
2002-01-01
Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome
Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R
2016-03-01
Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.
Are bio-absorbable stents the future of SFA treatment?
Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M
2010-02-01
Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.
International Nuclear Information System (INIS)
Mendez, Jose C.; Gonzalez-Llanos, Francisco
2005-01-01
We present a case of vertebral artery pseudoaneurysm after a posterior C1-C2 transarticular screw fixation procedure that was effectively treated with endovascular coil occlusion. Vertebral artery pseudoaneurysm complicating posterior C1-C2 transarticular fixation is extremely rare, with only one previous case having been reported previously. Endovascular occlusion is better achieved in the subacute phase of the pseudoaneurysm, when the wall of the pseudoaneurysm has matured and stabilized. Further follow-up angiographies are mandatory in order to confirm that there is no recurrence of the lesion
Artery Soft-Tissue Modelling for Stent Implant Training System
Directory of Open Access Journals (Sweden)
Giovanni Aloisio
2004-08-01
Full Text Available Virtual reality technology can be utilised to provide new systematic training methods for surgical procedures. Our aim is to build a simulator that allows medical students to practice the coronary stent implant procedure and avoids exposing patients to risks. The designed simulation system consists of a virtual environment and a haptic interface, in order to provide both the visualization of the coronary arteries and the tactile and force feedback generated during the interactions of the surgical instruments in the virtual environment. Since the arteries are soft tissues, their shape may change during an operation; for this reason physical modelling of the organs is necessary to render their behaviour under the influence of surgeon's instruments. The idea is to define a model that computes the displacement of the tissue versus time; from the displacement it is possible to calculate the response of the tissue to the surgical tool external stimuli. Information about tools displacements and tissue responses are also used to graphically model the artery wall and virtual surgical instrument deformations generated as a consequence of their coming into contact. In order to obtain a realistic simulation, the Finite Element Method has been used to model the soft tissues of the artery, using linear elasticity to reduce computational time and speed up interaction rates.
Self-expanding stent-assisted middle cerebral artery recanalization: technical note
International Nuclear Information System (INIS)
Sauvageau, Eric; Levy, Elad I.
2006-01-01
Investigation into pharmacological and mechanical means of improving recanalization rates by intraarterial therapy has led to technological development. Angiographic recanalization has been associated with improvement in clinical outcome. A clot retriever has recently joined an imperfect armamentarium for intraarterial stroke therapy. In this report, we describe successful recanalization of an acute thrombotic occlusion of the inferior division of the middle cerebral artery (MCA) achieved with a self-expanding stent. An 82-year-old woman with a history of coronary atherosclerosis and previous cerebellar hemorrhage presented with a National Institutes of Health Stroke Scale (NIHSS) score of 11. Perfusion computed tomography imaging showed a left MCA territory deficit. Diffusion-weighted magnetic resonance (MR) imaging revealed a small punctiform insular hyperintensity. Angiography documented occlusion of the inferior division of the left MCA (Thrombolysis in Myocardial Infarction or Thrombolysis in Cerebral Infarction, TIMI/TICI, grade 0). Intraarterial delivery of eptifibatide to the occlusion site failed to recanalize the vessel. Deployment of a self-expanding stent in the occluded segment resulted in complete revascularization of the distal vascular bed. Angiography performed on the next day confirmed patency of the stented vessel segment (TIMI/TICI 3). The patient was discharged 3 days after the procedure (NIHSS 3). MR angiography obtained 3 months after the procedure documented left MCA patency. This technique may have a role worthy of further investigation in acute stroke therapy. (orig.)
Stented Vessels: A Challenge for Histological Preparation and Microscopy
Directory of Open Access Journals (Sweden)
Andrea Nolte
2013-06-01
Full Text Available Objective: The first procedure to treat blocked coronary arteries was coronary artery bypass graft surgery. In 1977, Andreas Gruntzig introduced percutaneous transluminal coronary angioplasty (PTCA. Today, several stent systems exist ranging from bare metal stents to various drug-eluting stents. Unfortunately, our understanding of the arterial reaction to stent implantation is incomplete primarily due to technical limitations in the histological study of stented vascular tissue. Methods: In our study, we examined different histological preparation methods based on the embedding material methacrylate. The procedure of embedding and sectioning stented porcine arteries was optimized for the specific requirements, like histochemistry, immunohistochemistry or pre-stained fluorescence. Furthermore, we used a microscopical technique described as fluorescence intensity decay shape analysis microscopy (FIDSAM to eliminate auto-fluorescence from fluorescently labeled tissue. Results: The sections were suitable for histochemical and immunohistochemical staining. Additionally, pre-labeled fluorescence in the porcine tissue was not lost by the embedding process. The evaluation of arterial cross sections with FIDSAM technology gave new, very important insights into the examination possibilities of fluorescently labeled tissue. Conclusions: Future studies of the vascular response to a variety of new stent materials will provide important clues to the pathogenesis resulting in restenosis and occlusion of stents. [J Interdiscipl Histopathol 2013; 1(3.000: 104-112
Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms
International Nuclear Information System (INIS)
Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji
2012-01-01
Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.
International Nuclear Information System (INIS)
Jeon, Yong Sun; Cho, Soon Gu; Hong, Ki Cheon
2009-01-01
Spontaneous renal artery dissection (SRAD) is rare and presents a diagnostic and therapeutic challenge. We report a case of a 36-year-old man who had an SRAD-complicated renal infarction. The patient experienced severe unilateral flank pain. Enhanced abdominal computed axial tomography scan showed renal infarction, and urinalysis showed no hematuria. Selective renal angiography was essential to evaluate the extent of dissection and suitability for repair. The patient was treated with catheter-directed thrombolysis and frenal artery stenting.
International Nuclear Information System (INIS)
Rajesparan, K.; Partridge, W.; Refson, J.; Abidia, A.; Aldin, Z.
2014-01-01
Aim: To investigate the risk of endoleak during endovascular aneurysm repair (EVAR) involving the distal common iliac artery (CIA) when the internal iliac artery (IIA) is covered without prior coil embolization. Materials and methods: Retrospective analysis of 145 (125 men, 20 women) consecutive EVAR cases. Clinical notes and radiological images were reviewed, and data collected on patient demographics, aneurysm morphology, covering of the IIA with or without embolization, presence of endoleaks, and patient symptoms relating to IIA ischaemia. Results: A total of 29 IIAs (10%) were covered in a total of 25 patients. Seven IIAs (24%) were embolized before stent covering (Embolization group), and 22 IIAs (76%) were covered only without embolization (Cover group). There was no statistically significant difference in the mean size of the abdominal aortic aneurysm diameter or CIA diameter between each group. No endoleaks from IIA retrograde filling were found in either group. Conclusion: The results of the present study do not support the traditional view that coverage of the IIA without prior embolization carries a high risk of endoleak, with no endoleaks seen in all 22 cases. Large-scale trials are required. However, the advent of branched-stenting techniques and the emergence of their success in long-term follow-up may preclude the former. - Highlights: • No EVAR endoleaks due to retrograde filling of the internal iliac artery (IIA). • No increased risk of endoleak with stent coverage of the IIA without embolisation. • Current evidence does not support traditional views
Directory of Open Access Journals (Sweden)
MIN Li
2012-12-01
Full Text Available 【Abstract】 Harms technique of C1-C2 fixation for atlantoaxial complex becomes more popular due to good fusion rate and low vertebral artery injury (VAI rate. But considering the unique and variable anatomy of atlanto-axial complex, iatrogenic VAI will result in catastrophic con-sequences and provides particular surgical challenges for surgeons. To our knowledge, comparing with iatrogenic VAI in the screw hole, iatrogenic VAI in the “open space” is much rarer during the Harms technique of C1-C2 fixation. In this article, we present a case of iatrogenic vertebral artery pseudoaneurysm after Harms technique of posterior C1-C2 fixation. This case of iatrogenic VAI effectively treated by endovascular coil occlusion and external local compression was initially misdiagnosed as VAI by pedicle screw perforation. It can be concluded that intraoperative or post-operative computed angiography is very helpful to diag-nose the exact site of VAI and the combination of endovascular coil occlusion as well as external local com-pression can further prevent bleeding and abnormal verte-bral artery flow in the pseudoaneurysm. However, patients treated require further follow-up to confirm that there is no recurrence of the pseudoaneurysm. Key words: Vertebral artery; Aneurysm, false; Endovascular procedures
Wang, Hong-Yang; Liu, Long-Shan; Cao, Hai-Ming; Li, Jun; Deng, Rong-Hai; Fu, Qian; Zhang, Huan-Xi; Fei, Ji-Guang; Wang, Chang-Xi
2017-01-01
Background: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. Methods: Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann–Whitney U-test was used for analysis. Results: Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P = 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P = 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P = 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P = 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. Conclusions: Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or
Wang, Hong-Yang; Liu, Long-Shan; Cao, Hai-Ming; Li, Jun; Deng, Rong-Hai; Fu, Qian; Zhang, Huan-Xi; Fei, Ji-Guang; Wang, Chang-Xi
Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann-Whitney U-test was used for analysis. Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P= 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P= 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P= 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P= 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic
International Nuclear Information System (INIS)
Mueller-Huelsbeck, S.; Jahnke, T.; Grimm, J.; Behm, C.; Hilbert, C.; Frahm, C.; Biederer, J.; Brossmann, J.; Heller, M.
2002-01-01
Objective: To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). Patients and Methods: During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink TM 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfermoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88% ±10 and 9 mm ±5. Results: Renal stent implantation was technically successful in all cases (100%). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg ± 10 before to 1 mmHg ± 1.8 after the procedure. Remaining stenosis measured 0.7% ±4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n.s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p [de
International Nuclear Information System (INIS)
Lupattelli, Tommaso; Garaci, Francesco Giuseppe; Basile, Antonio; Minnella, Daniela Paola; Casini, Andrea; Clerissi, Jacques
2009-01-01
Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.
Wang, Dalin; Zheng, Shengnai; Liu, An; Xu, Jie; Du, Xiaotao; Wang, Yijin; Wang, Liming
2018-03-15
Biomechanical investigation using cadaver spines. The aim of the present study was to assess the magnitude of the deflation effect after balloon kyphoplasty (BKP) or use of minimally invasive vertebral body stent (MIVBS) in in vitro biomechanical condition. BKP is a well-established minimally invasive treatment option for osteoporotic vertebral compression fractures. However, this technique can lead to a secondary height loss-known as the "deflation effect"-causing intrasegmental kyphosis and an overall alignment failure. The study was conducted on 24 human cadaveric vertebral bodies (T12-L5). After creating a compression fracture model, the fractured vertebral bodies were reduced by BKP (n = 12) or by MIVBS (n = 12) and then augmented with polymethyl methacrylate bone cement. Each step of the procedure was performed under fluoroscopic guidance and the results were analyzed quantitatively. Finally, the strength and stiffness of augmented vertebral bodies were measured by biomechanical tests. Complete initial reduction of the fractured vertebral body height was achieved by both systems. Secondary loss of reduction after balloon deflation was significantly greater in the BKP group (2.36 ± 0.63 mm vs. 0.34 ± 0.43 mm in the MIVBS group; P deflation effect after BKP can be significantly decreased with the use of the MIVBS technique. N/A.
Design and modeling balloon-expandable coronary stent for manufacturability
Suryawan, D.; Suyitno
2017-02-01
Coronary artery disease (CAD) is a disease that caused by narrowing of the coronary artery. The narrowing coronary artery is usually caused by cholesterol-containing deposit (plaque) which can cause a heart attack. CAD is the most common cause mortality in Indonesia. The commonly CAD treatment use the stent to opens or alleviate the narrowing coronary artery. In this study, the stent design is optimized for the manufacturability. Modeling is used to determine the free stent expansion due to applied pressure in the inner surface of the stent. The stress distribution, outer diameter change, and dogboning phenomena are investigated in the simulation. The result of modeling and simulating was analyzed and used to optimize the stent design before it is manufactured using EDM (Electric Discharge Machine) in the next research.
Stent-assisted coil embolization for cavernous carotid artery aneurysms.
Kono, Kenichi; Shintani, Aki; Okada, Hideo; Tanaka, Yuko; Terada, Tomoaki
2014-01-01
Internal carotid artery (ICA) occlusion with or without a bypass surgery is the traditional treatment for cavernous sinus (CS) aneurysms with cranial nerve (CN) dysfunction. Coil embolization without stents frequently requires retreatment because of the large size of CS aneurysms. We report the mid-term results of six unruptured CS aneurysms treated with stent-assisted coil embolization (SACE). The mean age of the patients was 72 years. The mean size of the aneurysms was 19.8 mm (range: 13-26 mm). Before treatment, four patients presented with CN dysfunction and two patients had no symptoms. SACE was performed under local or general anesthesia in three patients each. Mean packing density was 29.1% and tight packing was achieved. There were no neurological complications. CN dysfunction was cured in three patients (75%) and partly resolved in one patient (25%). Transient new CN dysfunction was observed in two patients (33%). Clinical and imaging follow-up ranged from 6 to 26 months (median: 16 months). Recanalization was observed in three patients (50%; neck remnant in two patients and dome filling in one patient), but no retreatment has yet been required. No recurrence of CN dysfunction has occurred yet. In summary, SACE increases packing density and may reduce requirement of retreatment with an acceptable cure rate of CN dysfunction. SACE may be a superior treatment for coiling without stents and be an alternative treatment of ICA occlusion for selected patients, such as older patients and those who require a high-flow bypass surgery or cannot receive general anesthesia.
International Nuclear Information System (INIS)
Park, Sung Eun; Choi, Ho Cheol; Choi, Dae Seob; Lee, Sang Min; Lee, Jung Eun; Cho, Su Beom; Ahn, Jong Hwa
2017-01-01
A 60-year-old lean man with claudication due to severe stenosis of the right common iliac artery (CIA) underwent balloon-expandable stent deployment. Nineteen months later, claudication and lower limb ischemia in the patient recurred after minor external pressure and computed tomography indicated collapse of the right CIA stent. We performed balloon angioplasty again and self-expandable stent deployment was performed, and the patient's symptoms were relieved. We suggest that the CIA in a lean person could be susceptible to external pressure
Reversal of end-stage renal disease after aortic dissection using renal artery stent: a case report
Directory of Open Access Journals (Sweden)
Parikh Chirag R
2004-05-01
Full Text Available Abstract Background Medical management is the conventional treatment for Stanford Type B aortic dissections as surgery is associated with significant morbidity and mortality. The advent of endovascular interventional techniques has revived interest in treating end-organ complications of Type B aortic dissection. We describe a patient who benefited from endovascular repair of renal artery stenosis caused by a dissection flap, which resulted in reversal of his end-stage renal disease (ESRD. Case presentation A 69 y/o male with a Type B aortic dissection diagnosed two months earlier was found to have a serum creatinine of 15.2 mg/dL (1343.7 μmol/L on routine visit to his primary care physician. An MRA demonstrated a rightward spiraling aortic dissection flap involving the origins of the celiac artery, superior mesenteric artery, and both renal arteries. The right renal artery arose from the false lumen with lack of blood flow to the right kidney. The left renal artery arose from the true lumen, but an intimal dissection flap appeared to be causing an intermittent stenosis of the left renal artery with compromised blood flow to the left kidney. Endovascular reconstruction with of the left renal artery with stent placement was performed. Hemodialysis was successfully discontinued six weeks after stent placement. Conclusion Percutaneous intervention provides a promising alternative for patients with Type B aortic dissections when medical treatment will not improve the likelihood of meaningful recovery and surgery entails too great a risk. Nephrologists should therefore be aggressive in the workup of ischemic renal failure associated with aortic dissection as percutaneous intervention may reverse the effects of renal failure in this population.
Huang, Qing-Hai; Wu, Yong-Fa; Shen, Jie; Hong, Bo; Yang, Peng-Fei; Xu, Yi; Zhao, Wen-Yuan; Liu, Jian-Min
2013-02-01
The treatment of anterior communicating artery (AcomA) wide-necked aneurysms with the Enterprise stent (Codman, Miami Lakes, FL, USA) has not been commonly described, due to the complexity of the vascular anatomy and the small vessels of the AcomA complex. To evaluate the feasibility, effectiveness and safety of Enterprise stent placement in AcomA aneurysms, we performed this retrospective study. Between November 2008 and December 2010, 27 wide-necked AcomA ruptured aneurysms were treated within 72 hours of ictus with the Enterprise stent. Data collected and analyzed were: demographic data, morphologic features of the aneurysm, treatment results and follow-up results. Twenty-nine Enterprise stents were successfully deployed in all 27 aneurysms, including Y-configuration stent deployment in two patients. The initial embolization degrees were Raymond class I in 20 patients, class II in five and class III in the other two. The angiographic follow-up of 21 patients (mean, 8.4 months) showed that all aneurysms remained stable or improved; there was no in-stent stenosis, recurrence or retreatment. The clinical follow-up of 26 patients (mean, 12.6 months) showed that 23 patients displayed no symptoms and no or mild disability; three patients remained with severe or moderately severe disability. The Enterprise stent is feasible and safe for endovascular embolization of wide-necked AcomA ruptured aneurysms. Further follow up is needed to assess the long-term efficacy of Enterprise stent placement in AcomA. Copyright © 2012 Elsevier Ltd. All rights reserved.
In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT
International Nuclear Information System (INIS)
Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.
2011-01-01
Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.
Directory of Open Access Journals (Sweden)
Antonio Esteves Fº
1998-03-01
Full Text Available Mulher de 60 anos, com angina progressiva e revascularização do miocárdio, há oito anos, com ponte de veia safena para coronária direita e anastomose de artéria mamaria esquerda para artéria descendente anterior. Submetida a implante de stent Gianturco-Roubin II em terço proximal da ponte de veia safena para artéria coronária direita, com resultado insatisfatório pela persistência de lesão residual, provavelmente, decorrente de prolapso para dentro da luz de material aterosclerótico através dos coils. Foi implantado outro stent (Palmaz-Schatz biliar dentro do stent GRII com sucesso e ótimo resultado angiográfico. Um 2º stent Palmaz-Schatz biliar foi implantado em lesão distal no corpo da ponte, ultrapassando os dois stents, anteriormente implantados, com sucesso. Em algumas situações, implante de stent dentro de outro stent é recurso útil para otimização de resultado angiográfico do implante de um stent.A 60 year-old woman with progressive angina who had been submitted to saphenous bypass-graft to right coronary artery and a left mammary artery graft to anterior descending artery eight years previously, underwent implantation of a Gianturco Roubin II stent in the proximal third of the saphenous vein graft. The result was suboptimal by persistence of a residual stenosis probably due to prolapse of atherosclerotic material through the coil spaces. Another stent (Palmaz-Schatz biliar stent was implanted at the previously stented site with no residual stenosis. Another Palmaz-Schatz biliar stent was successfully implanted in the distal body of the graft to treat another lesion (passing through the previously stents without difficulty. Stenting a stent, in selected situations, is a useful tool to optimize the angiographic result of stent implantation.
Hemiparesis caused by vertebral artery compression of the medulla oblongata
International Nuclear Information System (INIS)
Kim, Phyo; Takahashi, Hiroshi; Shimizu, Hiroyuki; Yokochi, Masayuki; Ishijima, Buichi
1984-01-01
A case is reported of a patient with progressive left hemiparesis due to the vascular compression of the medulla oblongata. Metrizamide CT cisternography revealed the left vertebral artery to be compressing and distorting the left lateral surface of the medulla. This compression was relieved surgically, and the symptoms improved postoperatively. Neurological and symptomatic considerations are discussed in relation to the topographical anatomy of the lateral corticospinal tract. (author)
Energy Technology Data Exchange (ETDEWEB)
Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)
2013-06-15
We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.
Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron
2017-10-01
Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.
Neurorehabilitation in stroke produced by vertebral artery dissection: case presentation
Directory of Open Access Journals (Sweden)
Stanescu Ioana
2018-02-01
Full Text Available Arterial dissections are a common cause of stroke in the young (mean age 44 to 46 years. Primary lesion is a tear of the arterial intima, which promotes platelet aggregation, thrombus formation, which further produced vessel stenosis / occlusion, distal embolism or vessel wall rupture. Vertebral artery (VA dissection appear most commonly in extracranial segments V2 and V3, and could be spontaneous (with underlying predispositions or triggered by various traumatisms. Clinicaly, VA dissection produces an ischemic stroke or transient ischemic attack , preceded by local symptoms such as neck pain or headache. The diagnosis is confirmed by neurovascular imaging. Treatment of symptomatic VA dissections respect indications of treatment in ischemic strokes. Prognosis is mostly favorable in extracranial dissections. We present the case of a left VA dissection in V2 segment, produced by physical effort (swimming, which causes 2 ischemic lesions, one in the territory of the left posterior cerebral artery and the other in the territory of the left posterolateral chorroidal artery. Patient’s treatment included antiplatelet agents, statines, and an adapted physical rehabilitation program. At three months he showed significant clinical improvement with regain of autonomy and partial recanalisation at angio-MRI of the V2 segment of the dissected artery.
An experimental study on expandable endovascular metallic stents in dogs
Energy Technology Data Exchange (ETDEWEB)
Song, Ho Young; Kim, Hak Nam [Chonbuk National University College of Medicine, Chonju (Korea, Republic of)
1990-12-15
We constructed an expandable endovascular metallic stent in the same way as Giamturco did. Experiments were made to test the ability of these stents to be used in the vessels. A total of 20 stents were passed through a 8.5 French teflon sheath into the normal abdominal aorta. IVC, and iliac artery of four adult dogs for 4 weeks to 12 weeks; 8 stents (10 mm in diameter fully expanded and 20 mm in length) in the abnormal aorta, 7 stents (12 mm/20 mm) in the IVC, and 5 stents (8 mm/20 mm) in the iliac artery. All but two stents showed no migration, and one complete occlusion occurred in right iliac artery of a dog. Histologically, stents wires were covered by neo-intimal proliferation. The side branches of the main vessels remained patent, even stent wires across their orifices. These metallic stents may be used as an endovascular graft material in the nonsurgical treatment of several forms of vascular disease.
Müller-Hülsbeck, S; Jahnke, T; Grimm, J; Behm, C; Hilbert, C; Frahm, C; Biederer, J; Brossmann, J; Heller, M
2002-03-01
To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.
Fereidoonnezhad, B.; Naghdabadi, R.; Sohrabpour, S.; Holzapfel, G. A.
In-stent restenosis (ISR) is one of the main drawbacks of stent implementation which limits the long-term success of the procedure. Morphological changes occurring within the arterial wall due to stent-induced mechanical injury are a major cause for activation of vascular smooth muscle cells (VSMCs), and the subsequent development of ISR. Considering the theory of volumetric mass growth and adopting a multiplicative decomposition of the deformation gradient into an elastic part and a growth part, we present a mechanobiological model for ISR. An evolution equation is developed for mass growth of the neointima, in which the activation of VSMCs due to stent-induced damage (injury) and the proliferation rate of the activated cells are considered. By introducing the mass evolution into the mass balance equation, we obtain the evolution of the growth tensor over time. The model is implemented in a finite element code and the procedure of angioplasty is simulated, whereby the features of the proposed growth model are illustrated.
Focal ischemia of the brain after neuroprotected carotid artery stenting.
Schlüter, Michael; Tübler, Thilo; Steffens, Johann C; Mathey, Detlef G; Schofer, Joachim
2003-09-17
This study sought to assess the incidence of cerebral ischemia in nonselected patients undergoing neuroprotected carotid angioplasty and stenting (CAS) without preceding multiple-vessel diagnostic angiography. Protection devices to prevent distal embolization during CAS are presently under clinical investigation. Diffusion-weighted magnetic resonance imaging (MRI) visualizes recent ischemia of the brain and may aid in assessing the efficacy of protection devices. Elective CAS was performed in 42 consecutive patients (15 female, 27 male; mean age, 67 +/- 9 years) using six different types of cerebral protection systems. All patients underwent MRI of the brain before and after a total of 44 interventions. Placement and retrieval of the devices and stent deployment was achieved in all procedures. New ischemic foci were seen on postinterventional MRI in 10 cases (22.7%). One patient had sustained a major stroke, whereas no adverse neurological sequelae were associated with the other nine procedures. In the latter, one to three foci (maximum area 43.0 mm(2)) were detected in cerebral regions subtended by the ipsilateral carotid artery in eight cases and by the contralateral carotid artery in one case. In the stroke patient, 12 ischemic foci (maximum area 84.5 mm(2)) were exclusively located in the contralateral hemisphere. Follow-up MRI at 4.1 months (median, n = 7) identified residuals of cerebral ischemia only in this patient. Neuroprotected CAS is associated in about 25% of cases with predominantly silent cerebral ischemia. Our findings suggest manipulation of endoluminal equipment in the supraaortic vessels to be a major risk factor for cerebral embolism during neuroprotected CAS.
Energy Technology Data Exchange (ETDEWEB)
Park, Sung Eun; Choi, Ho Cheol; Choi, Dae Seob; Lee, Sang Min; Lee, Jung Eun [Gyeongsang National University School of Medicine and Gyeongsang National University Hospital, Jinju (Korea, Republic of); Cho, Su Beom; Ahn, Jong Hwa [Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon (Korea, Republic of)
2017-08-15
A 60-year-old lean man with claudication due to severe stenosis of the right common iliac artery (CIA) underwent balloon-expandable stent deployment. Nineteen months later, claudication and lower limb ischemia in the patient recurred after minor external pressure and computed tomography indicated collapse of the right CIA stent. We performed balloon angioplasty again and self-expandable stent deployment was performed, and the patient's symptoms were relieved. We suggest that the CIA in a lean person could be susceptible to external pressure.
New stent design for use in small coronary arteries during percutaneous coronary intervention
Directory of Open Access Journals (Sweden)
Juan F Granada
2010-10-01
Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS
Nakahara, Yukiko; Kawashima, Masatou; Matsushima, Toshio; Kouguchi, Motofumi; Takase, Yukinori; Nanri, Yusuke; Yakusiji, Yusuke
2014-01-01
It is well known that brainstem dysfunction may be caused by vascular compression of the medulla oblongata (MO). However, only a limited number of reports have found microvascular decompression (MVD) surgery to be an effective treatment for symptomatic patients with MO dysfunction, such as essential hypertension, pyramidal tract signs, dysphagia, and respiratory failure. This report describes 3 patients with vertebral artery compression of MO who presented with respiratory failure and/or dysphagia. MVD surgery using the transcondylar fossa approach was effective in relieving patient symptoms. Although the pathogenic mechanisms of symptomatic vertebral artery compression of MO remain unclear, we should recognize that MVD surgery is effective for selected patients with brainstem dysfunction. The transcondylar fossa approach and the stitched sling retraction technique are appropriate in MVD surgery to relieve vertebral artery compression of MO. Copyright © 2014 Elsevier Inc. All rights reserved.
Javaid, Aamir; Steinberg, Daniel H; Buch, Ashesh N; Corso, Paul J; Boyce, Steven W; Pinto Slottow, Tina L; Roy, Probal K; Hill, Peter; Okabe, Teruo; Torguson, Rebecca; Smith, Kimberly A; Xue, Zhenyi; Gevorkian, Natalie; Suddath, William O; Kent, Kenneth M; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron
2007-09-11
Advances in coronary artery bypass grafting (CABG) surgery and percutaneous coronary intervention (PCI) with drug-eluting stents have dramatically improved results of these procedures. The optimal treatment for patients with multivessel coronary artery disease is uncertain given the lack of prospective, randomized data reflecting current practice. This study represents a "real-world" evaluation of current technology in the treatment of multivessel coronary artery disease. A total of 1680 patients undergoing revascularization for multivessel coronary artery disease were identified. Of these, 1080 patients were treated for 2-vessel disease (196 CABG and 884 PCI) and 600 for 3-vessel disease (505 CABG and 95 PCI). One-year mortality, cerebrovascular events, Q-wave myocardial infarction, target vessel failure, and composite major adverse cardiovascular and cerebrovascular events were compared between the CABG and PCI cohorts. Outcomes were adjusted for baseline covariates and reported as hazard ratios. The unadjusted major adverse cardiovascular and cerebrovascular event rate was reduced with CABG for patients with 2-vessel disease (9.7% CABG versus 21.2% PCI; P<0.001) and 3-vessel disease (10.8% CABG versus 28.4% PCI; P<0.001). Adjusted outcomes showed increased major adverse cardiovascular and cerebrovascular event with PCI for patients with 2-vessel (hazard ratio 2.29; 95% CI 1.39 to 3.76; P=0.01) and 3-vessel disease (hazard ratio 2.90; 95% CI 1.76 to 4.78; P<0.001). Adjusted outcomes for the nondiabetic subpopulation demonstrated equivalent major adverse cardiovascular and cerebrovascular event with PCI for 2-vessel (hazard ratio 1.77; 95% CI 0.96 to 3.25; P=0.07) and 3-vessel disease (hazard ratio 1.70; 95% CI 0.77 to 3.61; P=0.19). Compared with PCI with drug-eluting stents, CABG resulted in improved major adverse cardiovascular and cerebrovascular event in patients with 2- and 3-vessel coronary artery disease, primarily in those with underlying diabetes
International Nuclear Information System (INIS)
Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis; Padayachee, Soundrie; Karunanithy, Narayan; Ahmed, Irfan; Zayed, Hany; Katsanos, Konstantinos
2015-01-01
PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery
Energy Technology Data Exchange (ETDEWEB)
Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Padayachee, Soundrie [King’s Health Partners, Department of Ultrasonic Angiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Karunanithy, Narayan; Ahmed, Irfan [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Zayed, Hany [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)
2015-08-15
PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.
Directory of Open Access Journals (Sweden)
João Luiz de Lara Elesbão
2010-06-01
Full Text Available Contexto: A hiperplasia intimal é a reação tardia mais comum decorrente da angioplastia. O uso de stents de cromo-cobalto é bem estudado na circulação coronariana, porém não há muitos estudos que abordem o uso desses stents nas circulações carotídea e periférica. Objetivo: Analisar mediante morfometria a reação intimal presente na artéria carótida de suínos submetidos a angioplastia isoladamente e a angioplastia seguida de implante de stent de cromo-cobalto. Materiais e métodos: Em oito suínos, foi realizada angioplastia da artéria carótida comum direita e angioplastia seguida de implante de um stent de cromo-cobalto na artéria carótida comum esquerda. Após 4 semanas, os animais foram submetidos a eutanásia para a retirada de amostras de tecido arterial e preparo de lâminas histológicas. As imagens das lâminas foram digitalizadas e analisadas por programa de morfometria digital. A análise estatística foi realizada através da média e desvio padrão das áreas em cada grupo, utilizando-se o Teste t de Student. O valor de p Background: Intimal hyperplasia is the most common delayed response to angioplasty. The use of cobalt-chromium stents is well studied in the coronary circulation; however, there are few studies on their use in the carotid and peripheral circulation. Objective: To analyze the intimal reaction in a swine carotid artery undergoing simple angioplasty and angioplasty followed by implantation of cobalt-chromium stent. Materials and methods: We carried out angioplasty in the right common carotid artery and angioplasty with cobalt-chromium stent in the left common carotid artery in eight swine. Four weeks later, all animals were sacrificed for arterial tissue sampling and preparation of histological slides. Slide images were scanned and analyzed using a digital morphometry program. Statistical analysis was performed by mean values and standard deviations of the areas in each group, using the Student's t
International Nuclear Information System (INIS)
Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco
2013-01-01
This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.
Energy Technology Data Exchange (ETDEWEB)
Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)
2013-02-15
This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.
Intracranial vertebral artery dissection with subarachnoid hemorrhage following child abuse
International Nuclear Information System (INIS)
Nguyen, Pamela H.; Burrowes, Delilah M.; Ali, Saad; Shaibani, Ali; Bowman, Robin M.
2007-01-01
Child abuse is often suspected based on particular patterns of injury. We report a case of intracranial vertebral artery dissection with subarachnoid hemorrhage (SAH) in a 3-month-old boy following child abuse. The mechanisms of injury and the clinical and imaging findings are discussed. This particular pattern of injury has rarely been reported in association with child abuse. We hope to raise physician awareness of child abuse when faced with these imaging findings. (orig.)
Vertebral artery dissection in weightlifter with performance enhancing drug use
Low, Andrew; Dovey, Julie; Ash-Miles, Janice
2011-01-01
This case report describes a transient ischaemic attack secondary to vertebral artery dissection (VAD) in a young male body builder. This occurred following weight training with weights across the back and shoulders. The patient was also known to take multiple performance enhancing agents including anabolic steroids, slimming agents, stimulants and human growth hormone. Cases of VAD have been described with cervical manipulation in the past and an association between the use of anabolic stero...
Intracranial vertebral artery dissection with subarachnoid hemorrhage following child abuse
Energy Technology Data Exchange (ETDEWEB)
Nguyen, Pamela H.; Burrowes, Delilah M.; Ali, Saad; Shaibani, Ali [Feinberg School of Medicine of Northwestern University, Department of Radiology, Chicago, IL (United States); Bowman, Robin M. [Feinberg School of Medicine of Northwestern University, Department of Neurological Surgery, Chicago, IL (United States)
2007-06-15
Child abuse is often suspected based on particular patterns of injury. We report a case of intracranial vertebral artery dissection with subarachnoid hemorrhage (SAH) in a 3-month-old boy following child abuse. The mechanisms of injury and the clinical and imaging findings are discussed. This particular pattern of injury has rarely been reported in association with child abuse. We hope to raise physician awareness of child abuse when faced with these imaging findings. (orig.)
Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.
Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T
2006-01-01
To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.
Suh, Yongsung; Ko, Young-Guk; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo
2015-07-01
This study investigated the outcomes of single-stent vs kissing-stents techniques in asymmetric complex aortoiliac bifurcation (ACAB) lesions. We retrospectively investigated 80 consecutive patients (69 males, 66.6 ± 8.7 years) treated with a single stent and 30 patients (26 males, 67.1 ± 7.7 years) treated with kissing stents for ACAB between January 2005 and December 2012 from a single-center cohort. A ACAB lesion was defined as a symptomatic unilateral common iliac artery stenosis (>50%) combined with intermediate stenosis (30%-50%) in the contralateral common iliac artery ostium. The primary end point was the primary patency of the ACAB. The baseline clinical characteristics did not differ significantly between the single-stent and the kissing-stents group. Technical success was achieved in all patients. The single-stent group required fewer stents (1.3 ± 0.5 vs 2.3 ± 0.8; P stent group (3%) required bailout kissing stents because of plaque shift to the contralateral side. The major complication rates were 8% in single-stent vs 13% in the kissing-stent group, which was similar (P = .399). At 3 years, the single-stent and kissing-stents group had similar rates of primary patency (89% vs 87%; P = .916) and target lesion revascularization-free survival (93% vs 87%; P = .462). The single-stent technique in ACAB was safe and showed midterm outcomes comparable with those of kissing stents. Considering the benefits, such as fewer stents, less bilateral femoral access, and the availability of contralateral access for future intervention, the single-stent technique may be an advantageous treatment option in ACAB. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Related anomalies of origin of left vertebral and left inferior thyroid arteries
International Nuclear Information System (INIS)
Sartor, K.; Freckmann, N.; Boeker, D.K.; Allgemeines Krankenhaus Altona, Hamburg
1981-01-01
The known rare occurrence of related anomalies of origin of vertebral and inferior thyroid arteries appears not to be documented in the angiographic literature. Three cases with manifestation on the left side are presented. Embryology is discussed briefly. Knowledge of such anomalies is of importance to surgeons as well as angiographers. (orig.) [de
Chhabra, Sachin; Chopra, Sanjeev; Kataria, Rashim; Sinha, Virendra Deo
2017-12-01
Spinal instrumentation using rods and screws have become procedure of choice for posterior fixation. Vertebral artery anatomy is highly variable in this region posing challenges during surgery. Our study used 3D printer model to understand the anatomy and variations in vertebral artery in live patients thereby providing an accurate idea about vertebral artery injury risk in these patients preoperatively and to rehearse the whole procedure. Ten patients of developmental craniovertebral junction (CVJ) anomalies who were planned for operative intervention in the Department of Neurosurgery at SMS Hospital from February 2016 to December 2016 were analysed using a 3D printer model. Out of twenty vertebral arteries studied in ten patients, two were hypoplastic and out of these one could not be appreciated on 3D printer model. Out of remaining nineteen, thirteen arteries were found to lie outside the joint, three were in lateral third, one traversed the middle third of joint and one lied in medial third. In one patient, the vertebral artery was stretched and it traversed horizontally over the joint. Out of ten patients studied, nine were having occipitalised atlas and so entry of these vertebral arteries into cranium were classified as given by Wang et al. into four types. By our study, 3D printer model was extremely helpful in analyzing joints and vertebral artery preoperatively and making the surgeon acquainted about the placement and trajectory of the screws accordingly. In our opinion, these models should be included as a basic investigation tool in these patients.
Chopra, Sanjeev; Kataria, Rashim; Sinha, Virendra Deo
2017-01-01
Background Spinal instrumentation using rods and screws have become procedure of choice for posterior fixation. Vertebral artery anatomy is highly variable in this region posing challenges during surgery. Our study used 3D printer model to understand the anatomy and variations in vertebral artery in live patients thereby providing an accurate idea about vertebral artery injury risk in these patients preoperatively and to rehearse the whole procedure. Methods Ten patients of developmental craniovertebral junction (CVJ) anomalies who were planned for operative intervention in the Department of Neurosurgery at SMS Hospital from February 2016 to December 2016 were analysed using a 3D printer model. Results Out of twenty vertebral arteries studied in ten patients, two were hypoplastic and out of these one could not be appreciated on 3D printer model. Out of remaining nineteen, thirteen arteries were found to lie outside the joint, three were in lateral third, one traversed the middle third of joint and one lied in medial third. In one patient, the vertebral artery was stretched and it traversed horizontally over the joint. Out of ten patients studied, nine were having occipitalised atlas and so entry of these vertebral arteries into cranium were classified as given by Wang et al. into four types. Conclusions By our study, 3D printer model was extremely helpful in analyzing joints and vertebral artery preoperatively and making the surgeon acquainted about the placement and trajectory of the screws accordingly. In our opinion, these models should be included as a basic investigation tool in these patients. PMID:29354734
Self-made Palmaz stent: an experimental swine model study
International Nuclear Information System (INIS)
He Shicheng; Teng Gaojun; Guo Jinhe; Fang Wen
2000-01-01
Objective: To investigate the histologic changes and physicochemical stability of self-made Palmaz stent placed in swine arteries. Methods: The self-made Palmaz stent was made of 316L stainless steel wire. Nine stents were respectively placed within internal carotid, renal and iliac arteries of six pigs. Pigs were euthanized at intervals of 0.5, 1 and 3 months respectively and angiography were performed. Immediately followed by light and electro scanning microscopy for the stent zones. Results: All stents were successfully implanted in the target arteries and were patent shown in the angiographic examination immediately after the stent placement. Eight stents (8/9) remained patent at the time before euthanasia. No migration of stent were shown in the follow-up angiography. Light and electron scanning microscopy showed that the surface of the stents was covered by a thin layer of endothelial cells 2 weeks after the procedure and completely covered after 4 weeks. No inflammation occurred. Conclusions: The self-made Palmaz stent has good physicochemical stability and histocompatibility with easy placement, rather long term patency, histopathologic stability and thus the promising for clinical application
Vertebral Artery Diameter and Flow: Nature or Nurture.
Tarnoki, Adam Domonkos; Fejer, Bence; Tarnoki, David Laszlo; Littvay, Levente; Lucatelli, Pierleone; Cirelli, Carlo; Fanelli, Fabrizio; Sacconi, Beatrice; Fagnani, Corrado; Medda, Emanuela; Farina, Filippo; Meneghetti, Giorgio; Horvath, Tamas; Pucci, Giacomo; Schillaci, Giuseppe; Stazi, Maria Antonietta; Baracchini, Claudio
2017-09-01
In contrast with the carotid arteries, the vertebral arteries (VAs) show considerable variation in length, caliber, and vessel course. This study investigated whether the variation in diameter and flow characteristics of the VAs might be inherited. A total of 172 Italian twins from Padua, Perugia, and Terni (54 monozygotic, 32 dizygotic) recruited from the Italian Twin Registry underwent B-mode and pulsed-wave Doppler ultrasound assessment of their VAs. VA diameters, peak systolic velocity (PSV) and end diastolic velocity (EDV) were assessed at the level of a horizontal V2 segment. Univariate quantitative genetic modeling was performed. Fourteen percent of the sample had VA hypoplasia. Within pair correlation in monozygotic twins was higher than in dizygotics (.552 vs. .229) for VA diameter. Age- and sex-adjusted genetic effect, under the most parsimonious model, accounted for 54.7% (95% CI: 42.2-69.1%) of the variance of VA diameter, and unshared environmental effect for 45.3% (95% CI: 30.9-57.8%). No heritability was found for the PSV of VA, but shared (34.1%; 95% CI: 16.7-53.7%) and unshared (65.9%; 95% CI: 45.9-83.1%) environmental factors determined the variance. EDV of VA is moderately genetically influenced (42.4%; 95% CI: 16.1-64.9%) and also determined by the unshared environment (57.6%; 95% CI: 34.7-83.7%). The diameter of the VAs is moderately genetically determined. Different factors influence the PSV and EDV of VAs, which may highlight the complex hemodynamic background of VA flow and help to understand the vertebral flow anomalies found by ultrasound. Copyright © 2017 by the American Society of Neuroimaging.
Percutaneous Stent-Graft Repair of a Mycotic Pulmonary Artery Pseudoaneurysm
International Nuclear Information System (INIS)
Chou Meichun; Liang Hueilung; Pan Huayban; Yang Chienfang
2006-01-01
Ruptured mycotic pulmonary pseudoaneurysm is a lethal complication. Emergent surgical repair is usually recommended, but still associated with a high mortality rate. We present a patient in whom mycotic pulmonary pseudoaneurysm was a complication after surgical lobectomy 2 weeks earlier. This patient had suffered from repeated massive hemoptysis. After emergent surgical repair of the ruptured pulmonary artery stump, another episode of massive hemorrhage occurred. The pulmonary arteriogram revealed a segmental stenosis and a large, wide-necked, lobulated pseudoaneurysm at the left proximal pulmonary artery. We deployed a balloon-expandable stent-graft (48 mm in length mounted on a 12 mm x 40 mm angioplasty balloon) across the stenotic segment and the neck of the pulmonary pseudoaneurysm. Hemostasis was achieved immediately and, under a 4-week antibiotic treatment, patient was transferred to a local hospital for medical care. This case report demonstrates the benefit of minimally invasive endovascular therapy in a critically ill patient. A literature review of the etiology and management of mycotic pulmonary pseudoaneurysm is included
Intractable vomiting caused by vertebral artery compressing the medulla: A case report
Directory of Open Access Journals (Sweden)
Lauren Gorton
2015-01-01
Full Text Available Vertebral artery compressing the medulla and causing intractable vomiting has only been reported once previously. We report a case of a 69-year-old woman with intractable nausea and vomiting causing a 50 pound weight loss and who failed medical management and whose symptoms were completely reversed following microvascular decompression (MVD.
International Nuclear Information System (INIS)
Menendez, J.A.; Baskaya, M.K.; Day, M.A.; Nanda, A.
2001-01-01
Occipital condylar fractures (OCF) are rare and have a high mortality rate. We report a patient with OCF who presented with acute hydrocephalus and died from diffuse vasospasm secondary to vertebral artery injury. A 45-year-old man fell 20 feet from a deer stand and landed on his head. CT showed a type III OCF continuing to the anterior rim of the foramen magnum on the left, with a bone fragment pushing into the medulla, causing hydrocephalus. The patient was stabilized, and a four-vessel arteriogram showed diffuse vasospasm with complete occlusion of the left vertebral artery at the level of the OCF. To our knowledge, this is the first documented case of the conjunction of OCF, hydrocephalus, and vasospasm. (orig.)
Directory of Open Access Journals (Sweden)
Marc Bosiers
2008-09-01
Full Text Available Due to the fear that early thrombosis and late luminal loss resulting from intimal hyperplasia might impede sustained patency of small-caliber arteries, such as those of the infrapopliteal bed, stent implantation in below-knee vessels remains controversial and is generally reserved for cases with a suboptimal outcome after percutaneous transluminal angioplasty (i.e. > 50% residual stenosis, flow-limiting dissection. Although evidence starts to build, favoring the use of stenting in the tibial area, results of well-conducted randomized controlled trials have to be awaited to change this strategy. Because of diameter similarities with coronary arteries, the first stents applied in the infrapopliteal vessels were all coronary devices. Once the feasibility of the stenting approach with these coronary products was shown, device manufacturers started to develop a dedicated infrapopliteal product range. To date, a broad spectrum of stent types has been used and investigated for the given indication. This article overviews the available literature and results of different balloon-expandable (bare metal, passive coated, drug eluting, self-expanding and absorbable stent types available for below-the-knee application and gives recommendations for future device technology advancements.Devido ao receio de que a trombose precoce ou a estenose tardia por hiperplasia intimal possam impedir a manutenção da perviedade em vasos de pequeno calibre, o uso de stents pós-angioplastia no leito arterial infrapoplíteo permanece controverso e geralmente é reservado aos casos de resultado subótimo após angioplastia transluminal percutânea (isto é, estenose residual > 50% ou dissecção com limitação do fluxo. Apesar de evidências começarem a favorecer o uso de stents no segmento tibial, é necessário aguardar o resultado de ensaios controlados, randomizados e bem conduzidos para mudar esta estratégia. Sendo estes vasos infrapoplíteos de diâmetro similar
Investigation Of Interaction Between Nitinol Stent And A Vascular Plaque Using Finite Element Method
Directory of Open Access Journals (Sweden)
Recep Güneş
2012-06-01
Full Text Available In this study, the interaction between the Nitinol stent and the artery with plaque was investigated using finite element method. The occurring pressure values during the cardiac contraction (systolic and loosening (diastolic were applied as loading to the modeled system with Nitinol stent. In the light of the stress values, the suitability of the Nitinol stent in an artery with plaque was investigated. In the analysis, Nitinol stent was assumed to be shape memory alloy, and artery and plaque were assumed to behave linearly elastic. As a result, the stress and deformations in the plaque and artery due to the interference of Nitinol stent were discussed and concluded that the structure of artery with plaque can be expanded in accordance with Nitinol stent.
Directory of Open Access Journals (Sweden)
Ozge Korkmaz
2016-01-01
Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.
International Nuclear Information System (INIS)
Krajickova, Dagmar; Krajina, Antonin; Nova, Marketa; Raupach, Jan
2005-01-01
We report on a 72-year-old female with an unusual intracranial bleeding complication after an extracranial carotid artery stenting procedure performed for a tight left ICA stenosis associated with contralateral carotid occlusion. Two hours after the procedure, the initial signs of intracranial bleeding appeared that led to the patient's demise 5 days later. A brain CT showed and autopsy proved massive intraventricular bleeding. To our knowledge, our case is only the second report of isolated reperfusion intraventricular hemorrhage post-CAS
Bunte, Matthew C; Cohen, David J; Jaff, Michael R; Gray, William A; Magnuson, Elizabeth A; Li, Haiyan; Feiring, Andrew; Cioppi, Marco; Hibbard, Robert; Gray, Bruce; Khatib, Yazan; Jessup, David; Patarca, Roberto; Du, Jing; Stoll, Hans-Peter; Massaro, Joe; Safley, David M
2018-03-09
To evaluate the clinical and health status outcomes of patients undergoing superficial femoral artery (SFA) revascularization using the Shape Memory Alloy Recoverable Technology (S.M.A.R.T.®) nitinol self-expanding stent through 3 years of follow-up. Limited long-term data are available describing the durability of benefits after femoropopliteal revascularization. In a multicenter, prospective, core-lab adjudicated study, 250 subjects with de novo or restenotic femoropopliteal arterial lesions were treated with the S.M.A.R.T.® stent. The primary endpoint of target vessel patency, a composite of ultrasound-assessed patency and freedom from clinically driven target lesion revascularization (TLR), was evaluated through 3 years. Secondary endpoints included stent fracture and health status. Health status was measured using generic and disease-specific instruments, including the Peripheral Artery Questionnaire (PAQ). At 3-year follow-up, Kaplan-Meier estimated target vessel patency was 72.7%, freedom from clinically driven TLR was 78.5%, and the incidence of stent fracture was 3.6%. The PAQ summary score was markedly impaired at baseline (mean 37.3 ± 19.6 points) and improved substantially at 1 month (mean change from baseline of 31.4 points, 95% CI: 28.5-34.3; P PAQ were largely preserved through 3 years of follow-up (mean change from baseline, 28.0 points, 95% CI: 24.3-31.7; P < 0.0001). In patients undergoing revascularization for moderately complex SFA disease, use of the self-expanding S.M.A.R.T® stent was associated with a high rate of target vessel patency through 3 years and led to substantial and sustained health status benefits. © 2018 Wiley Periodicals, Inc.
DEFF Research Database (Denmark)
Weigang, Ernst; Parker, Jack A T C; Czerny, Martin
2011-01-01
subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...
A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection
International Nuclear Information System (INIS)
Rivolta, Nicola; Fontana, Federico; Piffaretti, Gabriele; Tozzi, Matteo; Carrafiello, Gianpaolo
2010-01-01
We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.
International Nuclear Information System (INIS)
Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Ogur, Erkin; Tekatas, Aslan
2008-01-01
To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 ± 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm 2 to 10.80 cm 2 at 45 minutes and 10.81 cm 2 at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs
Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Tekatas, Aslan; Ogur, Erkin
2008-01-01
To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 +/- 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm(2) to 10.80 cm(2) at 45 minutes and 10.81 cm(2) at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs.
Energy Technology Data Exchange (ETDEWEB)
Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Ogur, Erkin [Firat University School of Medicine, Elazig(Turkmenistan); Tekatas, Aslan [Elazig Government Hospital, Elazig (Turkmenistan)
2008-12-15
To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 +- 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm{sup 2} to 10.80 cm{sup 2} at 45 minutes and 10.81 cm{sup 2} at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs
International Nuclear Information System (INIS)
Gao Xu; Liang Guobiao; Li Zhiqing; Wei Xuezhong; Wang Xiaogang; Zhang Haifeng; Feng Sizhe; Lin Jun
2012-01-01
Background: There is a potential risk of aneurysm rupture after parent artery revascularization because of increased blood flow. The purpose of this study is to assess the efficacy and safety of Wingspan stent-assisted coil embolization in the treatment of intracranial aneurysms with symptomatic parent artery stenosis. Methods: Thirty-five consecutive patients (19 men, 16 women; age range, 48–79 years; mean age, 60.4 years) harboring 35 unruptured wide-necked or fusiform intracranial aneurysms (mean size 6.8 mm; range 2.5–18 mm.) with symptomatic parent artery stenosis (mean degree 71.1%; range 50–92%) were treated with the Wingspan stent-assisted coiling. Twenty-four lesions were located in the anterior circulation and eleven in the posterior circulation. Patients were premedicated with antiplatelet therapy consisting of aspirin 300 mg and clopidogrel 75 mg for at least 3 days before the procedure. Following pre-dilatation and stent placement, a coiling microcatheter entered the aneurysm through the interstices of the stent, and then coiling was performed. After the procedure, clopidogrel 75 mg daily was recommended for an additional 30 days, and aspirin 100 mg was recommended throughout follow-up. For all patients, clinical follow-up was conducted by clinic visitation, or telephone interview. Angiographic follow-up with DSA was recommended at 6 months and 1 year after the procedure. Angiography follow-up (mean time 10.6 months) was obtained in 31 cases (88.6%). The technical feasibility of the procedure, procedure-related complications, angiographic results, clinical outcome and follow-up angiography were evaluated. Results: In every case, technical success was achieved. The degree of stenosis was reduced from 71.1% to 17.4% after balloon angioplasty and stenting. Immediate angiography demonstrated complete occlusion in 25 cases (71.4%), neck remnant in 7 cases (20.0%), and incomplete occlusion in 3 cases (8.6%). Procedure-related morbidity occurred in two
International Nuclear Information System (INIS)
Harnek, Jan; Zoucas, Evita; Carlemalm, Erik; Cwikiel, Wojciech
1999-01-01
Purpose: To evaluate which of six different commonly available stents inserted into an artery without percutaneous transluminal angioplasty (PTA) causes the least endothelial damage. To compare the degree of endothelial injury after insertion of such a stent with injury caused by PTA. Methods: Twelve healthy pigs were used in the experiments. In the first part of the study six different types of stents were inserted into the common iliac arteries. In the second part of the study self-expanding stents with large spaces between the wires were used. PTA was performed in the contralateral iliac artery. The pigs were killed immediately after the procedure and resected specimens examined after fixation, using scanning electron microscopy. Results: All procedures but two were accomplished successfully. More endothelium was preserved after insertion of self-expanding stents with large spaces between the wires, compared with stents with small spaces and balloon-expanded stents. After insertion of self-expanding stents with large spaces, 50.1% ± 16.4% of the endothelium remained intact, compared with only 5.6% ± 7.7% after PTA. The difference was statistically significant (p < 0.001). Conclusion: Self-expanding stents with large spaces between the wires, inserted without PTA, cause less damage to the endothelium than other stents and significantly less damage than PTA
[Current guidelines on carotid artery stenting. Critical evaluation].
Hein-Rothweiler, R; Mudra, H
2013-11-01
Scientific data underlying current guidelines on treatment of carotid artery stenosis is subject to interdisciplinary discussion. In particular selective weighting of the randomized European studies leads to conflicting levels of recommendation and levels of evidence, especially when directly comparing guidelines under surgical versus endovascular guidance. Surgical guidelines recommend a limitation of carotid artery stenting (CAS) to symptomatic patients with specific surgical/anatomical disadvantages and/or severe comorbidities. The European Society of Cardiology (ESC) guidelines recommend the use of CAS only in patients at increased surgical risk but at the same time requires morbidity and mortality rates comparable to those of surgical interventions. Even one step further, the American guidelines and specifically the associated comments of the German Society of Cardiology on the above mentioned ESC guidelines put CAS and carotid endarterectomy (CEA) on a par in terms of treatment alternatives, presupposing analogous CEA complication rates. Differential interpretation of the so far inadequate data is a common issue of current evidence-based medicine. The difficulty in conceptualization of new studies concerning the therapy of carotid stenosis lies in the funding these large projects and also on the high patient number required to achieve adequate statistical power. Furthermore, during the estimated long study period substantial changes of current techniques and devices can be anticipated which might render the study results in part outdated by the time of publication. However, as long as no new randomized study results comparing medical, surgical and interventional treatment of carotid stenosis are available, the question on the optimal therapy for patients with carotid artery disease remains unanswered.
Salerno, Alexis; Cotter, Bradford V; Winters, Michael E
2017-05-01
Acute cerebrovascular accident (CVA) is a devastating cause of patient morbidity and mortality. Up to 10% of acute CVAs in young patients are caused by dissection of the vertebral or carotid artery. Wallenberg syndrome results from a CVA in the vertebral or posterior inferior artery of the cerebellum and manifests as various degrees of cerebellar dysfunction. The administration of a thrombolytic medication has been recommended in the treatment of patients with stroke caused by cervical artery dissection. Surprisingly, there is scant literature on the use of this medication in the treatment of this condition. We describe a 42-year-old man with the sudden onset of headache, left-sided neck pain, vomiting, nystagmus, and ataxia 1 h after completing a weightlifting routine. Computed tomography angiography revealed a grade IV left vertebral artery injury with a dissection flap extending distally and resulting in complete occlusion. Subsequent magnetic resonance imaging and angiography demonstrated acute left cerebellar and lateral medullary infarcts, consistent with Wallenberg syndrome. The patient was treated with tissue plasminogen activator, which failed to resolve his symptoms. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians frequently manage patients with acute CVAs. For select patients, the administration of tissue plasminogen activator can improve outcomes. However, the risk of major hemorrhage with this medication is significant. Cervical artery dissection is an important cause of acute stroke in young patients and is often missed on initial presentation. It is imperative for the emergency physician to consider acute cervical artery dissection as a cause of stroke and to be knowledgeable regarding the efficacy of thrombolytic medications for this condition. Copyright © 2017 Elsevier Inc. All rights reserved.
Neointimal responses 3 months after 32P β-emitting stent placement
International Nuclear Information System (INIS)
Farb, Andrew; Tang, Anita L.; Shroff, Sweta; Sweet, William; Virmani, Renu
2000-01-01
Purpose: Studies have shown a potential benefit of brachytherapy in preventing restenosis. However, the effects of intravascular radiation on arterial healing have not been well-established. The purpose of this study was to explore the histologic changes following placement of β-emitting radioactive stents in arteries focusing on intimal responses and endothelialization. Methods and Materials: 3.0-mm β-emitting 32 P stents (6-μCi and 24-μCi) were placed in rabbit iliac arteries with nonradioactive stents serving as controls. Animals were euthanized at 3 months and histologic assessment, morphometry, and analysis of endothelialization were performed. Results: The lumen areas of 24-μCi stents (4.24 ± 0.22 mm 2 , p 2 , p 2 ). The mean lumen percent stenosis was 11.4 ± 3.0% in the 24-μCi stents (p 32 P β-emitting stents reduce neointimal growth, but healing is incomplete with poor endothelialization at 3 months. Longer-term studies with complete arterial healing are needed to determine whether there is sustained neointimal inhibition by stent-delivered brachytherapy
Directory of Open Access Journals (Sweden)
Lee CH
2014-01-01
Full Text Available Cheng-Hung Lee,1,2 Yu-Huang Lin,3 Shang-Hung Chang,1 Chun-Der Tai,3 Shih-Jung Liu,2 Yen Chu,4 Chao-Jan Wang,5 Ming-Yi Hsu,5 Hung Chang,6 Gwo-Jyh Chang,7 Kuo-Chun Hung,1 Ming-Jer Hsieh,1 Fen-Chiung Lin,1 I-Chang Hsieh,1 Ming-Shien Wen,1 Yenlin Huang81Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Linkou, 2Department of Mechanical Engineering, 3Graduate Institute of Medical Mechatronics, Chang Gung University, 4Laboratory of Cardiovascular Physiology, Division of Thoracic and Cardiovascular Surgery, 5Department of Medical Imaging and Intervention, 6Hematology-Oncology Division, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, 7Graduate Institute of Clinical Medicinal Sciences, Chang Gung University College of Medicine, Linkou, 8Department of Anatomical Pathology, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, TaiwanAbstract: Incomplete endothelialization, blood cell adhesion to vascular stents, and inflammation of arteries can result in acute stent thromboses. The systemic administration of acetylsalicylic acid decreases endothelial dysfunction, potentially reducing thrombus, enhancing vasodilatation, and inhibiting the progression of atherosclerosis; but, this is weakened by upper gastrointestinal bleeding. This study proposes a hybrid stent with biodegradable nanofibers, for the local, sustained delivery of acetylsalicylic acid to injured artery walls. Biodegradable nanofibers are prepared by first dissolving poly(D,L-lactide-co-glycolide and acetylsalicylic acid in 1,1,1,3,3,3-hexafluoro-2-propanol. The solution is then electrospun into nanofibrous tubes, which are then mounted onto commercially available bare-metal stents. In vitro release rates of pharmaceuticals from nanofibers are characterized using an elution method, and a high-performance liquid chromatography assay. The experimental results suggest that biodegradable nanofibers
Energy Technology Data Exchange (ETDEWEB)
Higuma, Takumi, E-mail: higuma@cc.hirosaki-u.ac.jp; Abe, Naoki; Hanada, Kenji; Yokoyama, Hiroaki; Tomita, Hirofumi; Okumura, Ken
2014-04-15
A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.
Zhang, Jian; Li, Haiyan; Wang, Wu; Huang, Hua; Pei, Jia; Qu, Haiyun; Yuan, Guangyin; Li, Yongdong
2018-03-15
Mg-based stent is a promising candidate of the next generation fully degradable vascular stents. The latest progress includes the CE approval of the Magmaris ® WE43 based drug eluting stent. However, so far, the long term (more than 1 year implantation) in vivo degradation and the physiological effects caused by the degradation products were still unclear. In this study, a 20 month observation was carried out after the bare Mg-Nd-Zn-Zr (abbr. JDBM) stent prototype was implanted into the common carotid artery of New Zealand white rabbit in order to evaluate its safety, efficacy and especially degradation behavior. The degradation of the main second phase Mg 12 Nd was also studied. Results showed that the bare JDBM stent had good safety and efficacy with a complete re-endothelialization within 28 days. The JDBM stent struts were mostly replaced in situ by degradation products in 4 month. The important finding was that the volume and Ca concentration of the degradation products decreased in the long term, eliminating the clinicians' concern of possible vessel calcification. In addition, the alloying elements Mg and Zn in the stent could be safely metabolized as continuous enrichment in any of the main organs were not detected although Nd and Zr showed an abrupt increase in spleen and liver after 1 month implantation. Collectively, the long term in vivo results showed the rapid re-endothelialization of JDBM stent and the long term safety of the degradation products, indicating its great potential as the backbone of the fully degradable vascular stent. Mg-based stent is a promising candidate of the next generation fully degradable stents, especially after the recent market launch of one of its kind (Magmaris). However the fundamental question about the long term degradation and metabolic mechanism of Mg-based stent and its degradation products remain unanswered. We implanted our patented Mg-Nd-Zn-Zr bare stent into the common carotid artery of rabbits and
International Nuclear Information System (INIS)
Kordecki, Kazimierz; Łukasiewicz, Adam; Nowicki, Mirosław; Lewszuk, Andrzej; Kowalewski, Radosław; Panek, Bogusław; Zawadzki, Michał; Michalak, Paweł; Gacko, Marek; Łebkowska, Urszula
2012-01-01
The goal of this work was to assess the effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion classified according to TASC using a self-expanding stent Jaguar SM. The study group included 95 patients (61 men and 34 women) who underwent treatment for stenosis or occlusion of lower limb arteries at the Department of Radiology of the University Hospital in Bialystok and the Diagnostic Radiology Department of the Central Clinical Hospital of the Ministry of Interior (MSWiA) in Warsaw between 2005 and 2007. All arterial lesions were of atherosclerotic etiology. The shortest stenotic fragment was 10 mm long and the longest occluded arterial fragment did not exceed 90 mm. Morphological classification of iliac artery lesions in treated patients was performed according to TASC II classification and included 10 patients with type A, 39 cases of type B, 36 with type C and 10 patients with type D lesions. Endovascular procedure failed to restore flow in five patients with TASC type D lesions, who were later referred for surgery. One patient suffered a complication – vessel perforation during predilatation, and had a stentgraft implanted. In 95% of patients stents were expanded using a balloon after implantation. Good results were achieved in practically all patients who underwent stent implantation. Patients were subjected to follow-up clinical and imaging evaluation during next 1–24 months. Success rate of the performed procedures as well as in a 30-day observation period was 100% in case of stenosis and 80% in case of vessel occlusion. A follow-up after 12 and 24 months showed patency of treated vessels in 84% and 76% of patients, respectively
XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent
Beijk, Marcel A. M.; Piek, Jon J.
2007-01-01
Drug-eluting stents (DES) have been shown to be safe and significantly reduce clinical events and angiographic restenosis in the percutaneous treatment of coronary artery disease. Currently, three DES have been approved in Europe and Northern America: the sirolimus-eluting stent (SES), the
Combined endovascular and surgical treatment in vertebral arteriovenous fistula
International Nuclear Information System (INIS)
Nakstad, P.H.; Haakonsen, M.; Magnaes, B.; Hetland, S.
1997-01-01
A 7-year-old girl with a right-sided congenital arteriovenous fistula in the neck was admitted with signs of cardial incompensation. Her fistula was fed from the right vertebral artery in antegrade as well as retrograde directions. A steal from the intracranial arteries was established. In addition, smaller feeding arteries from the neck were found. She was operated on with ligation of the right vertebral artery proximal to the fistula but the attempted ligation of the artery cranially to the fistula was unsuccessful. She was therefore embolized by the formation of a plug of platinum fiber coils in the upper right vertebral artery. Catheterization was performed from the left vertebral artery via the basilar artery. Persisting minor feeders to the fistula from cervical arteries were embolized in a second session. Finally, surgical extirpation of the fistula was performed together with the operative ligation of a crossover feeding artery from the left vertebral artery. Her heart size, heart rate and blood pressure were successively normalized. (orig.)
DEFF Research Database (Denmark)
Giustino, Gennaro; Mastoris, Ioannis; Baber, Usman
2016-01-01
OBJECTIVES: The aim of this study was to investigate the clinical correlates and prognostic impact of coronary artery calcification (CAC) in women undergoing percutaneous coronary intervention with drug-eluting stents (DES). BACKGROUND: The clinical correlates and the prognostic significance of CAC...
High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation
International Nuclear Information System (INIS)
Nemes, Balazs; Lukacs, Levente; Balazs, Gyoergy; Dosa, Edit; Berczi, Viktor; Huettl, Kalman
2009-01-01
Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 ± 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 ± 8% before the procedure to 15.7 ± 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.
Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.
Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D
2016-05-01
Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.
Outcome of Carotid Artery Stenting for Radiation-Induced Stenosis
International Nuclear Information System (INIS)
Dorresteijn, Lucille; Vogels, Oscar; Leeuw, Frank-Erik de; Vos, Jan-Albert; Christiaans, Marleen H.; Ackerstaff, Rob; Kappelle, Arnoud C.
2010-01-01
Purpose: Patients who have been irradiated at the neck have an increased risk of symptomatic stenosis of the carotid artery during follow-up. Carotid angioplasty and stenting (CAS) can be a preferable alternative treatment to carotid endarterectomy, which is associated with increased operative risks in these patients. Methods and Materials: We performed a prospective cohort study of 24 previously irradiated patients who underwent CAS for symptomatic carotid stenosis. We assessed periprocedural and nonprocedural events including transient ischemic attack (TIA), nondisabling stroke, disabling stoke, and death. Patency rates were evaluated on duplex ultrasound scans. Restenosis was defined as a stenosis of >50% at the stent location. Results: Periprocedural TIA rate was 8%, and periprocedural stroke (nondisabling) occurred in 4% of patients. After a mean follow-up of 3.3 years (range, 0.3-11.0 years), only one ipsilateral incident event (TIA) had occurred (4%). In 12% of patients, a contralateral incident event was present: one TIA (4%) and two strokes (12%, two disabling strokes). Restenosis was apparent in 17%, 33%, and 42% at 3, 12, and 24 months, respectively, although none of the patients with restenosed vessels became symptomatic. The length of the irradiation to CAS interval proved the only significant risk factor for restenosis. Conclusions: The results of CAS for radiation-induced carotid stenosis are favorable in terms of recurrence of cerebrovascular events at the CAS site.
Cervical chordoma with vertebral artery encasement mimicking neurofibroma: MRI findings
Energy Technology Data Exchange (ETDEWEB)
Mortele, B.; Lemmerling, M.; Mortele, K.; Verstraete, K.; Defreyne, L.; Kunnen, M. [Department of Radiology, University Hospital, Gent (Belgium); Vandekerckhove, T. [Department of Neurosurgery, University Hospital, Gent (Belgium)
2000-06-01
A case of cervical chordoma in a 36-year-old white man with hypoesthesia in the neck and right shoulder, neck pain, and restricted neck mobility is presented. Plain radiographs of the cervical spine showed radiolucency of the body of C2 on the right side and enlargement of the right intervertebral foramen at C2-C3 level. Tumor encasement of the vertebral artery was demonstrated by MR imaging and confirmed by conventional arteriography. This proved to be particularly important for preoperative assessment. (orig.)
Cervical chordoma with vertebral artery encasement mimicking neurofibroma: MRI findings
International Nuclear Information System (INIS)
Mortele, B.; Lemmerling, M.; Mortele, K.; Verstraete, K.; Defreyne, L.; Kunnen, M.; Vandekerckhove, T.
2000-01-01
A case of cervical chordoma in a 36-year-old white man with hypoesthesia in the neck and right shoulder, neck pain, and restricted neck mobility is presented. Plain radiographs of the cervical spine showed radiolucency of the body of C2 on the right side and enlargement of the right intervertebral foramen at C2-C3 level. Tumor encasement of the vertebral artery was demonstrated by MR imaging and confirmed by conventional arteriography. This proved to be particularly important for preoperative assessment. (orig.)
Directory of Open Access Journals (Sweden)
Birger Mensel
Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.
Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M
2013-11-01
Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.
Myla, Subbarao; Bacharach, J Michael; Ansel, Gary M; Dippel, Eric J; McCormick, Daniel J; Popma, Jeffrey J
2010-05-01
The multicenter EPIC (FiberNet Embolic Protection System in Carotid Artery Stenting Trial) single-arm trial evaluated the 30-day outcomes of a new design concept for embolic protection during carotid artery stenting (CAS). Embolic protection filters available for use during CAS include fixed and over-the-wire systems that rely on embolic material capture within a "basket" structure. The FiberNet Embolic Protection System (EPS), which features a very low crossing profile, consists of a three-dimensional fiber-based filter distally mounted on a 0.014 inch guidewire with integrated aspiration during filter retrieval. The trial enrolled 237 patients from 26 centers. Demographics, clinical and lesion characteristics, as well as adverse events through a 30-day follow-up were recorded. The mean age of the patients was 74 years, 64% were male and 20% had symptomatic carotid artery disease. The combined major adverse event (MAE) rate at 30 days for all death, stroke, and myocardial infarction was 3.0%. There were three major strokes (two ischemic and one hemorrhagic) and two minor strokes (both ischemic) for a 2.1% 30-day stroke rate. The procedural technical success rate was 97.5% and macroscopic evidence of debris was reported in 90.9% of the procedures. The FiberNet EPS, used with commercially available stents, produced low stroke rates following CAS in high surgical risk patients presenting with carotid artery disease. The unique filter design including aspiration during retrieval may have contributed to the low 30-day stroke rate reported during CAS in patients considered at high risk for complications following carotid endarterectomy (CEA). Copyright 2010 Wiley-Liss, Inc.
Directory of Open Access Journals (Sweden)
Ben Hur Junitiro Kajimoto
2007-01-01
Full Text Available O aumento da utilização de novas técnicas e materiais de síntese para o tratamento cirúrgico de afecções da coluna cervical baixa foi acompanhado da crescente preocupação em relação às complicações que podem ocorrer. A técnica de fixação transpedicular, amplamente utilizada para os outros níveis da coluna vertebral, quando realizada na coluna cervical, apesar de conferir maior estabilidade quando comparada a outras técnicas, pode cursar com complicações graves como lesão da artéria vertebral, lesão de raiz nervosa, além de lesão da articulação facetária. A vértebra C7, no entanto, é considerada mais segura para a realização de tal procedimento, já que, na grande maioria das pessoas, segundo os estudos anatômicos disponíveis, esta não possui a artéria vertebral dentro de seu forame transverso, pois este vaso irá penetrar tal estrutura apenas na vértebra C6. Como hoje existem apenas estudos de imagem para avaliação do trajeto desta artéria e suas variações anatômicas, realizamos este estudo anatômico dissecando 40 artérias vertebrais de cadáveres para avaliar a incidência das variações anatômicas. Encontramos 3 casos onde a artéria vertebral penetrou o forame transverso já em C7 (7,5%, o que aumentaria o risco de uma técnica transpedicular neste nível. O restante das peças anatômicas possuíam anatomia habitual.The increasing use of new techniques and materials for surgical treatment of lower cervical spine conditions has come along with an increasing concern regarding potential complications that might occur. The transpedicular fixation technique, frequently used in other spine levels, is used on the cervical spine, while providing more stability than other techniques, it may cause serious complications such as vertebral artery injury, nervous root injury, or facet joint injuries. However, the C7 vertebra is considered safer for performing this procedure, since, in the vast majority of
Ngo, A. T.; Markar, S. R.; de Lijster, M. S.; Duncan, N.; Taube, D.; Hamady, M. S.
2015-01-01
To evaluate outcomes following treatment of transplant renal artery stenosis by percutaneous transluminal angioplasty and stent insertion. A literature search was performed using Pubmed, MEDLINE, Embase, Wiley Interscience and the Cochrane Library databases. Outcome measures were glomerular
Endovascular stenting for treatment of complex intracranial aneurysms: preliminary outcome
International Nuclear Information System (INIS)
Huang Qinghai; Liu Jianmin; Xu Yi; Hong Bo; Zhao Wenyuan; Zhou Xiaoping
2004-01-01
Objective: To summarize the technique and efficiency of combined endovascular stenting and Guglielmi detachable coils (GDC) packing for the treatment of intracranial wide-necked bifurcation aneurysms and recanalized aneurysms. Methods: The coronary stents were implanted across the necks of 5 intracranial wide-necked aneurysms (two at bifurcation of ICA, one at basilar artery and two recanalized PcoA aneurysms). The porous stents covered the ostia of vital side branches and perforating vessels in three cases. Microcatheters were introduced into the aneurysmal sac through the stent mesh and then followed by GDCs embolizing the aneurysms. Results: The stents were deployed in parent artery in all cases. Total occlusion was obtained in 4 cases, while more than 90% in one case with patency of the parent arteries and vital perforating arteries. Follow-up angiography performed in all patients 3-6 months later revealed no intrastent stenosis. All the patients recovered well except III nerve palsy in one patient which diminished 3 months later. Conclusion: Endovaseular therapy combined stent implantation and microcoil placement maybe a valid alteration for the treatment of wide-necked bifurcation aneurysms and recanalized aneurysms, which shows promise clinical application in the future. The ostia of vital side branches covered with stents showed no effect on hemodynamics. (authors)
Directory of Open Access Journals (Sweden)
Abdulrahman Almutairi
2015-05-01
Full Text Available Objective: To identify the optimal dual-energy computed tomography (DECT scanning protocol for peripheral arterial stents while achieving a low radiation dose, while still maintaining diagnostic image quality, as determined by an in vitro phantom study. Methods: Dual-energy scans in monochromatic spectral imaging mode were performed on a peripheral arterial phantom with use of three gemstone spectral imaging (GSI protocols, three pitch values, and four kiloelectron volts (keV ranges. A total of 15 stents of different sizes, materials, and designs were deployed in the phantom. Image noise, the signal-to-noise ratio (SNR, different levels of adaptive statistical iterative reconstruction (ASIR, and the four levels of monochromatic energy for DECT imaging of peripheral arterial stents were measured and compared to determine the optimal protocols. Results: A total of 36 scans with 180 datasets were reconstructed from a combination of different protocols. There was a significant reduction of image noise with a higher SNR from monochromatic energy images between 65 and 70 keV in all investigated preset GSI protocols (p < 0.05. In addition, significant effects were found from the main effect analysis for these factors: GSI, pitch, and keV (p = 0.001. In contrast, there was significant interaction on the unstented area between GSI and ASIR (p = 0.015 and a very high significant difference between keV and ASIR (p < 0.001. A radiation dose reduction of 50% was achieved. Conclusions: The optimal scanning protocol and energy level in the phantom study were GSI-48, pitch value 0.984, and 65 keV, which resulted in lower image noise and a lower radiation dose, but with acceptable diagnostic images.
Bunc, Matjaž; Kocijančič, Igor J.; Pregelj, Rado; Dolenc, Vinko V.
2010-01-01
Embolic occlusion of cerebral arteries is a major cause for stroke. Intravenous thrombolysis showed positive results in this condition, however even when strict criteria are used, the risk of hemorrhagic transformation is possible. Microsurgical embolectomy has been described earlier. Purpose. We performed multimodal therapy of cerebral artery occlusion. Case Report. We present a case of a 49-year-old female patient who—according to the National Institute of Health Stroke Scale (NIHSS)—was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA). After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach—without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA. PMID:20671974
Bunc, Matjaz; Kocijancic, Igor J; Pregelj, Rado; Dolenc, Vinko V
2010-01-01
Embolic occlusion of cerebral arteries is a major cause for stroke. Intravenous thrombolysis showed positive results in this condition, however even when strict criteria are used, the risk of hemorrhagic transformation is possible. Microsurgical embolectomy has been described earlier. Purpose. We performed multimodal therapy of cerebral artery occlusion. Case Report. We present a case of a 49-year-old female patient who-according to the National Institute of Health Stroke Scale (NIHSS)-was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA). After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach-without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA.
DEFF Research Database (Denmark)
Chevalier, Bernard; Dimario, Carlo; Neumann, Franz-Josef
2013-01-01
The ZOMAXX I trial tested the noninferiority of a zotarolimus-eluting coronary stent (ZoMaxx(™) ) when compared with a paclitaxel-eluting coronary stent (Taxus(™) Express(2™) ) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. Angiographic analysis at the pr...
International Nuclear Information System (INIS)
Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel; Pendenza, Gianluca; Spinelli, Alessio; Stefanini, Matteo; Simonetti, Giovanni
2005-01-01
A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the complete exclusion of the pseudoaneurysm
Gupta, Ankur; Bajaj, Navkaranbir S; Arora, Pankaj; Arora, Garima; Qamar, Arman; Bhatt, Deepak L
2018-02-01
Randomized controlled trials (RCTs) have shown fractional flow reserve-guided (FFR) multivessel stenting to be superior to infarct-related artery (IRA) only stenting in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease. This effect was mainly driven by a reduction in overall repeat revascularization. However, the ability to assess the effect of this strategy on urgent revascularization or reinfarction was underpowered in individual trials. We searched Pubmed, EMBASE, Cochrane CENTRAL, and Web of Science for RCTs of FFR-guided multivessel stenting versus IRA-only stenting in STEMI with multivessel disease. The outcomes of interest were death, reinfarction, urgent, and non-urgent repeat revascularization. Risk ratios (RR) were pooled using the DerSimonian and Laird random-effects model. After review of 786 citations, 2 RCTs were included. The pooled results demonstrated a significant reduction in the composite of death, reinfarction, or revascularization in the FFR-guided multivessel stenting group versus IRA-only stenting group (RR [95%, Confidence Interval]: 0.49 [0.33-0.72], p<0.001). This risk reduction was driven mainly by a reduction in repeat revascularization, both urgent (0.41 [0.24-0.71], p=0.002) and non-urgent revascularization (0.31 [0.19-0.50], p<0.001). Pooled RR for reinfarction was lower in the FFR-guided strategy, but was not statistically significant (0.71[0.39-1.31], p=0.28). This systematic review and meta-analysis suggests that a strategy of FFR-guided multivessel stenting in STEMI patients reduces not only overall repeat revascularization but also urgent revascularization. The effect on reinfarction needs to be evaluated in larger trials. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Evaluation of Silicone as an Endovascular Stent Membrane: In Vivo Canine Studies
International Nuclear Information System (INIS)
Fontaine, Arthur B.; Borsa, John J.; Hoffer, Eric; Bloch, Robert; So, Corali
2001-01-01
Purpose: Comparative evaluation of the biological effects of a silicone-covered stent versus a bare-metal stent, in an animal model.Methods: Twelve stent implants were placed in the iliac arteries of six adult dogs. Each animal received one 8-mm x 20-mm silicone-covered stent (Permalume; Boston Scientific Vascular, Watertown, MA, USA), in the right iliac artery and one Wallstent (Boston Scientific Vascular) of the same diameter and length in the left iliac artery, during systemic anticoagulation. Angiography was performed before and after implantations. Animals were then allowed to recover and no platelet suppression was given during a 6-week interval, after which the animals were euthanized. The stented arteries were isolated and pressure-fixed in situ with 10% buffered formalin at a pressure of approximately 100 mmHg for a period of 1 hr. Two of 12 stented specimens were opened lengthwise and the luminal surfaces were photographed. Ten of 12 stented arterial segments were encased in methacrylate, then stained with hematoxylin and eosin. Neointimal thickness was quantified on histologic cross-section, for both bare and covered stents. The mean neointimal thicknesses were compared for significant difference using a student t-test.Results: All implants were widely patent at 6-week follow-up angiography. Histologic analysis showed bare metal stents covered by a thin uniform lining of neointima composed of smooth muscle cells in a hyaline matrix (mean thickness of 189 ± 47 μm). Silicone covered stents were devoid of neointima. There was no chronic thrombus or mature endothelium noted anywhere upon the internal silicone surfaces of any of the specimens. There was no foreign body reaction to the silicone cover.Conclusion: Short-term implantation of a silicone-lined Wallstent in canine iliac arteries is well tolerated. Silicone appears to be inert at 6 weeks in this experimental application
Mondon, K; de Toffol, B; Georgesco, G; Cassarini, J-F; Machet, M-C; Cottier, J-P; Arbeille, B; Autret, A
2004-04-01
Dissection of cervical arteries is a frequent cause of stroke in young subjects. We report the case of a 34-year-old patient who experienced simultaneous dissection of both internal carotid arteries and both vertebral arteries leading to repeated motor deficit of the right half-body associated with persistent otalgia. Search for an etiology led to the diagnosis of Ehlers-Danlos syndrome type IV. Search for the cause of cervical artery dissection must consider connective tIssue disease, particularly vascular forms of Ehler-Danlos syndrome. Diagnostic, therapeutic as well as prognostic aspects are discussed.
Energy Technology Data Exchange (ETDEWEB)
Kuya, Keita; Shinohara, Yuki; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Brain and Neurosciences, Faculty of Medicine, Yonago (Japan); Iwata, Naoki; Kishimoto, Junichi [Tottori University, Division of Clinical Radiology Faculty of Medicine, Yonago (Japan); Kaminou, Toshio [Osaka Minami Medical Center, Department of Radiology, Osaka (Japan)
2014-11-15
Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS. (orig.)
International Nuclear Information System (INIS)
Kuya, Keita; Shinohara, Yuki; Fujii, Shinya; Ogawa, Toshihide; Sakamoto, Makoto; Watanabe, Takashi; Iwata, Naoki; Kishimoto, Junichi; Kaminou, Toshio
2014-01-01
Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS. (orig.)
Illuminati, Giulio; Pizzardi, Giulia; Pasqua, Rocco; Frezzotti, Francesca; Palumbo, Piergaspare; Macrina, Francesco; Calio', Francesco
2018-04-01
Tandem stenoses of the internal carotid artery (ICA) and proximal, ipsilateral common carotid artery (CCA) or innominate artery can be treated with a hybrid approach, combining conventional carotid endarterectomy (CEA) and retrograde stenting of the proximal stenosis, through surgical exposure of the carotid bifurcation. The purpose of this study was to evaluate the results of combining eversion CEA with retrograde CCA/innominate artery stenting. From January 2015 to July 2017, 7 patients, 6 men of a mean age of 72 years (range 59-83 years) underwent simultaneous, retrograde stenting of the proximal CCA/innominate artery and an eversion CEA of the ipsilateral ICA, through surgical exposure of the carotid bifurcation, for severe tandem stenoses. The proximal stenosis involved the left proximal CCA in 4 patients, the proximal innominate artery in 2 patients and the right CCA in one patient. The procedure was performed under general anesthesia in a conventional operating room equipped with a mobile C-arm. A covered, balloon expandable stent was deployed over the proximal stenosis via a 6-F sheath directly introduced into the proximal CCA through the obliquely transected carotid bulb. After removing the sheath, debris were flushed through the carotid bulb and eversion CEA completed the procedure. Study endpoints were: postoperative stroke/mortality rate, cardiac mortality and morbidity, peripheral nerve injury, cervical hematoma, overall late survival, freedom from ipsilateral stroke and patency of arterial reconstruction. No postoperative mortality or neurologic morbidity was observed in any patient. Cervical hematomas and peripheral nerve injuries were likewise absent. At a mean follow-up of 18 months, all the patients were alive, free from neurologic events of new onset and free from restenosis. Combined proximal stenting and eversion CEA for tandem lesions seems a valid treatment, with the advantages of eversion CEA over other techniques of carotid bifurcation
International Nuclear Information System (INIS)
Suzuki, Shigeru; Furui, Shigeru; Kaminaga, Tatsuro; Miyazawa, Akiyoshi; Ueno, Yasunari; Konno, Kumiko; Kuwahara, Sadatoshi; Mehta, Dhruv
2009-01-01
We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans. As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen. The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error. The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution
Vascular stents: Coupling full 3-D with reduced-order structural models
International Nuclear Information System (INIS)
Avdeev, I; Shams, M
2010-01-01
Self-expanding nitinol stents are used to treat peripheral arterial disease. The peripheral arteries are subjected to a combination of mechanical forces such as compression, torsion, bending, and contraction. Most commercially available peripheral self-expanding stents are composed of a series of sub-millimeter V-shaped struts, which are laser-cut from a nitinol tube and surface-treated for better fatigue performance. The numerical stent models must accurately predict location and distribution of local stresses and strains caused by large arterial deformations. Full 3-D finite element non-linear analysis of an entire stent is computationally expensive to the point of being prohibitive, especially for longer stents. Reduced-order models based on beam or shell elements are fairly accurate in capturing global deformations, but are not very helpful in predicting stent failure. We propose a mixed approach that combines the full 3-D model and reduced-order models. Several global-local, full 3-D/reduced-order finite element models of a peripheral self-expanding stent were validated and compared with experimental data. The kinematic constraint method used to couple various elements together was found to be very efficient and easily applicable to commercial FEA codes. The proposed mixed models can be used to accurately predict stent failure based on realistic (patient-specific), non-linear kinematic behavior of peripheral arteries.
Directory of Open Access Journals (Sweden)
Jian-ping DENG
2011-12-01
Full Text Available Objective The present study aims to probe into the feasibility and safety of larger balloons in the self-expandable stent Wingspan system when treating symptomatic intracranial arterial stenosis.Methods The clinical data of 109 symptomatic intracranial arterial stenosis patients,consisting of 68 males and 41 females,were analyzed.These patients were treated via angioplasty using the Wingspan system from March 2007 to June 2010.The ages of the patients ranged from 36 years to 79 years,with an average of 62.4.The patients were divided into two groups according to the sizes of the Gateway balloons they used.The balloon diameter for group A(n=31 was based on 80% of the diameter of the normal blood vessels on both sides of the arterial vessel.Meanwhile,the balloon diameter for group B was based on the average diameter of the vessels on both sides of the arterial vessel.The effects of the treatment and the occurrence of complications in both groups were analyzed and compared.Results The degree of arteriostenosis before operation for group A was 56.0% to 87.8%,with an average of 71.8%,residual stenosis after operation was 0% to 45%,with an average of 24.9%.The degree of ateriostenosis before operation for group B was 68.9% to 98.0%,with an average of 76.0%,residual stenosis after operation was 0% to 21%,with an average of 10.2%.Group A had four cases(12.9% of durability neurological dysfunction.One case was a visual-field defect.In group B,six patients(7.7% experienced complications.The differences were not statistically significant,and no deaths occurred in both groups.Conclusions Wingspan stent angioplasty is a safe and effective treatment for intracranial arterial stenosis,and even the use of larger balloons does not increase the risk in patients.
The Effect of Stent Cell Geometry on Carotid Stenting Outcomes
Energy Technology Data Exchange (ETDEWEB)
Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)
2016-04-15
PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.
Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W; Park, Seung-Jung
2016-12-26
The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD). The relative efficacy and safety of CABG versus PCI with DES for left main or multivessel CAD remain controversial. Data were pooled from the BEST (Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease), PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery vs. Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease), and SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) trials. The primary outcome was a composite of all-cause death, myocardial infarction, or stroke. The median follow-up was 60 months, and follow-up was completed for 96.2% of patients. The rate of primary outcome was significantly lower with CABG than with PCI (13.0% vs. 16.0%; hazard ratio [HR]: 0.83; 95% confidence interval [CI]: 0.69 to 1.00; p = 0.046). The difference was mainly driven by reduction in myocardial infarction (HR: 0.46; 95% CI: 0.33 to 0.64; p patients with multivessel CAD (p = 0.001), but no between-group difference in those with left main CAD (p = 0.427). The rates for all-cause death and stroke were similar between the 2 groups. By contrast, the need for repeat revascularization was significantly lower in the CABG group compared with the PCI group. CABG, as compared with PCI with DES, reduced long-term rates of the composite of all-cause death, myocardial infarction, or stroke in patients with left main or multivessel CAD. The advantage of CABG over PCI with DES was particularly pronounced in those with multivessel CAD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights
Directory of Open Access Journals (Sweden)
Li Shen
2015-01-01
Full Text Available Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES, compared with traditional sirolimus-eluting stent (SES. Methods: Patients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF, and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR by telephone visit and late luminal loss (LLL at 9-month by angiographic follow-up. Results: From July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980. Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028. There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008. Conclusions: After 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.
Hemifacial spasm; The value of vertebral angiography
International Nuclear Information System (INIS)
Yang, Hak Seok; Kim, Myung Soon; Han, Yong Pyo
1992-01-01
In order to evaluate the value of vertebral angiography in assesment of hemifacial spasm, We reviewed retrospectively the vertebral angiography of 28 patients (30 cases) with surgically proved hemifacial spasm but normal CT scans of posterior fossa. There were 9 males and 19 females. Angiography revealed vascular focus of hemifacial spasm located at anterior inferior cerebellar artery , posterior inferior cerebellar artery, and vertebral artery in 19, 9, and 2 cases respectively. Right side was involved in 20 cases. All involved vessels were elongated, tortuous, and dilated. In conclusion, vertebral angiography was valuable in evaluating hemifacial spasm of vascular origin in the posterior fossa
Directory of Open Access Journals (Sweden)
Bishu K
2015-07-01
Full Text Available Kalkidan Bishu,1,2 Ehrin J Armstrong1,21Division of Cardiology, University of Colorado, Aurora, 2Denver VA Medical Center, Denver, CO, USAAbstract: Femoropopliteal lesions account for a significant proportion of endovascular interventions for peripheral artery disease in patients with disabling claudication or chronic limb ischemia. The femoropopliteal artery crosses two joint structures (hip and knee joints and courses through the muscular adductor canal in the thigh, which places the artery at increased biomechanical stress. There is a critical need for stent platforms with a reduced risk of stent fracture while maintaining patency during long-term follow-up. The Supera peripheral stent system has a braided nickel–titanium alloy stent designed to withstand the unique stressors along the course of the femoropopliteal artery. This design may be associated with improved patency in association with reduced stent fracture rates on short- and medium-term follow-up. Further studies, including randomized controlled studies, comparing the Supera interwoven nickel–titanium alloy stent system with other stent platforms and angioplasty alone are needed.Keywords: peripheral artery disease, femoropopliteal atherosclerosis, SUPERA interwoven nitinol stent, stent fracture